HomeMy WebLinkAbout123 E. Anahurst Pl - Plan1081695 CONTRACTOR LICENSE NUMBER AERIAL VIEW GENERAL NOTES PROJECT NOTES: THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE LOCAL ELECTRIC CODE ( ) ARTICLE 690, ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTIONS (AHJ) APPLICABLE CODES. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICRO INVERTER IN ACCORDANCE WITH 690.41(B). ALL PV SYSTEM COMPONENTS, MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE. INVERTERS UL1741 CERTIFIED, IEEE 1547, 929, 519. COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO 690.7. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 ((D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING 110.3. ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE AND AHJ. WORK INCLUDED: PV ROOF ATTACHMENTS PV RACKING SYSTEM INSTALL ATION - EVEREST CROSSRAIL 44-X PV MODULE AND INVERTER INSTALLATION PV EQUIPMENT GROUNDING. PV SYSTEM WIREING TO A ROOF-MOUNTED JUNCTION BOX. PV LOAD CENTERS (IF INCLUDED). PV METERING/MONITORING (IF INCLUDED). PV DISCONNECTS. PV FINAL COMMISSIONING. (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. PLANSET-1 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 9/14/2022 MJ 3 COVER SHEET PS-1 TABLE OF CONTENTS: PS-1 - COVER SHEET PS-2 - SITE NOTES PS-3 - SITE PLAN PS-4 -FIRE ACCESS PS-5 - MODULE AREA PS-6 - RACKING DETAIL PS-7 - ELECTRICAL LINE PS-8 - PLACARDS FM-1 FIELD MARKINGS RS-1 - RS-6 - RESOURCE DOCUMENT SCOPE OF WORK: INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SYSTEM 4.44kW AC PHOTOVOLTAIC SOLAR ARRAY PV MODULES: SILFAB - 370 NX INVERTER(S): SE3800-US ROOF TYPE: Composition Shingle PV MOUNTING HARDWARE: QUICK BOLT (QB2) 17662 (COMP SHINGLE) AHJ:SANTA ANA BUILDING CODE:2019 CBC ELECTRICAL CODE:2019 CEC FIRE CODE:2019 CBC RESIDENTIAL CODE:2019 CRC CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA CEC CEC CEC CEC CEC CEC MODULE QUANTITY: 12 09/19/2022 VSE Project Number: U4879.0061.221 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw connections to the existing framing. The design of the racking system, racking connections, and all other structural is by others. Mechanical, architectural, and all other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. BLDG # 101112676 ISSUED: 11/08/2022 ELECT # 20177888 ISSUED: 11/10/2022 123 E. Anahurst Pl 11/10/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Solid State Electric LLC 1081695 123 E Anahurst Pl. Santa Ana, CA 92707 Isaac Thompson 435-773-0279 11/08/2022 isaac.thompson@flexenergysolar.com 123 E. Anahurst Pl 11/10/22 120/240 VAC 60HZ SINGLE PHASE UTILITY SERVICE LL L L N EQUIPPED WITH RAPID SHUTDOWN, INTEGRATED DC DISCONNECT & ARC FAULT PROTECTION EGC L2 L1 EGC L2 L1 L2 L1 EGC AA B JUNCTION BOX (OPTIONAL - FOR CONDUCTOR SPLICE) JUNCTION BOX (OPTIONAL - FOR CONDUCTOR SPLICE) (1) STRING OF 12 MODULES GN D N INVERTER 1 (240V) SOLAREDGE SE 3800H-US MODULE TYPE: SILFAB - 370 NX UL 1703 INVERTER TYPE: SE3800-US UL 1741VISIBLE LOCKABLE LABELED PV AC DISCONNECT 30A, 240V, 2P, NON- FUSED LOCKABLE, VISIBLE OPEN EGC N L2 L1 N N C GN D N L2 L1 C GEC N EGC C (N) SECONDARY POWER SOURCE (PV OCPD) TO BE LOCATED AT OPPOSITE END OF BUSBAR FROM PRIMARY SOURCE (MAIN OCPD) (NEC 705.12) (E) GROUNDING ELECTRODE SYSTEM LOAD-SIDE SOURCE CONNECTION SUBPANEL BUSBAR PLUG-IN TYPE BREAKER (NEC 705.12) (E)LOADS (E)LOADS GN D N L2 L1 N EGC (E)125A/2P (N)20A/2P (E)125A SUBPANEL (E)125A MAIN SERVICE PANEL (E)125A/2P MAIN DISCONNECT 1081695 CONTRACTOR LICENSE NUMBER PLANSET-7 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 ELECTRICAL LINE DIAGRAM PS-7CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA MPU REQUIRED: NO TAG CONDUCTOR TYPE MINIMUM WIRE SIZE # OF CONDUCTORS RACEWAY/ CABLE TYPE MINIMUM CONDUIT SIZE A CABLE (USE-2)12 2 USE-2 / FREE AIR FREE AIRBARE COPPER (EGC)6 1 BARE / FREE AIR B CU THHN OR NM-B CABLE *10 4 EMT OR EQUIVALENT / NM-B CABLE OR UF-B / FLEX 3/4" INTERIOR USECU THHN OR NM-B CALBE (EGC)*10 2 C CU THHN/THWN-2 10 3 EMT OR EQUIVALENT 3/4"CU THHN/THWN-2 (EGC)10 1 AHJ:SANTA ANA BUILDING CODE:2019 CBC ELECTRICAL CODE:2019 CEC FIRE CODE:2019 CBC RESIDENTIAL CODE:2019 CRC VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 123 E. Anahurst Pl 11/10/22 123 E. Anahurst Pl 11/10/22 RS1 123 EAST ANAHURST PLACE FRONT OF HOME 1081695 CONTRACTOR LICENSE NUMBER (E) MAIN SERVICE PANEL (E) UTILITY METER / MAIN SERVICE PANEL (E) SUBPANEL (N) PV LOAD CENTER (N) PV PRODUCTION METER FIRE SETBACK (N) AC DISCONNECT (VISIBLE LOCKABLE LABELED DISCONNECT) (N) PV MODULE SYSTEM LEGEND (N) PV COMBINER PANEL (N) JUNCTION BOX (N) DC-DC / STRING INVERTER (N) MICROINVERTER (N) DC DISCONNECT ROOF SECTION CRITERIA AND SPECIFICATIONS PLANSET-4 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 (IRE ACCESS AND ROO( IN(ORMATION PS-4 all modules will be installed in compliance with fire code.2019 CBC CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA AHJ:SANTA ANA BUILDING CODE:2019 CBC ELECTRICAL CODE:2019 CEC FIRE CODE:2019 CBC RESIDENTIAL CODE:2019 CRC VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 ROOF SECTION QUANTITY KILOWATTAGE ROOF PITCH AZIMUTH TSRF RS1 12 4.44kW 20° 181 94% RS2 0kW RS3 0kW RS4 0kW RS5 0kW 3'-0" 3'-0" 1'-6" 1'-6" 09/19/2022 VSE Project Number: U4879.0061.221 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw connections to the existing framing. The design of the racking system, racking connections, and all other structural is by others. Mechanical, architectural, and all other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. 123 E. Anahurst Pl 11/10/22 RS1 123 EAST ANAHURST PLACE FRONT OF HOME 1081695 CONTRACTOR LICENSE NUMBER (E) MAIN SERVICE PANEL (E) UTILITY METER / MAIN SERVICE PANEL (E) SUBPANEL (N) PV LOAD CENTER (N) PV PRODUCTION METER FIRE SETBACK (N) AC DISCONNECT (VISIBLE LOCKABLE LABELED DISCONNECT) (N) PV MODULE SYSTEM LEGEND (N) PV COMBINER PANEL (N) JUNCTION BOX (N) DC-DC / STRING INVERTER (N) MICROINVERTER (N) DC DISCONNECT PLANSET-5 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 MODULE AREA AND RAFTER INFORMATION PS-5 ROOF MEMBERS CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA AHJ:SANTA ANA BUILDING CODE:2019 CBC ELECTRICAL CODE:2019 CEC FIRE CODE:2019 CBC RESIDENTIAL CODE:2019 CRC FRAMING TYPE: Manufactured Wood Truss RAFTER SIZE: 2x4 RAFTER SPACING: 24 RAFTER SPAN: 72 ROOF TYPE: Composition Shingle SHEATHING TYPE: 7/16" OSB STRUCTURE TYPE:Inhabited - Gable / Flat Roof WIND EXPOSURE CATEGORY:B NUMBER OF PV ARRAYS:1 TOTAL ROOF AREA (SQ. FT):2200 VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 09/19/2022 VSE Project Number: U4879.0061.221 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw connections to the existing framing. The design of the racking system, racking connections, and all other structural is by others. Mechanical, architectural, and all other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. 123 E. Anahurst Pl 11/10/22 3'-9" 5'-9" (aptos 370 watt) dna-120-mf26-370w 1081695 CONTRACTOR LICENSE NUMBER *NOT TO SCALE*NOT TO SCALE *NOT TO SCALE LAG BOLT EMBEDMENT: 3" LAG BOLT DIAMETER: 5/16" PLANSET-6 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 6/28/2022 MJ 1 RAC -IN) AN& ASSEMBL; &ETAIL PS-6 structural information: HOME IS FRAMED WITH 2X4 TRUSSES AT 24" ON CENTER. construction notes: 1. solar photovoltaic system to be installed on residential structure. 2. this project has been designed in compliance with cbc section 1609 to withstand a basic wind speed of 110 mph (3 second gust), 3. connection to structure shall not be within 6" of nailing plates. 4. the solar PV installation shall not obstruct any plumbing, mechanical or building roof vents. 5. all conductors and conduits mounted on roof shall be minimum 3 3 4" above roof surface (including cables underneath modules and racking). 6. roof access points shall be provided per the following (cec r324.6, cvc 3111.2.1): located in areas not requiring placement of ground ladders over openings such as doors or windows. located at strong points of building construction in locations where access point does not conflict with overhead obstructions such as: tree limbs, wires or signs. CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA AHJ: BUILDING CODE:2019 CBC ELECTRICAL CODE:2019 CEC FIRE CODE:2019 CBC RESIDENTIAL CODE:2019 CRC07/07/2022 VSE Project Number: U4879.0027.221 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw connections to the existing framing. The design of the racking system, racking connections, and all other structural is by others. Mechanical, architectural, and all other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. 123 E. Anahurst Pl 11/10/22 RS1 123 EAST ANAHURST PLACE FRONT OF HOME 1081695 CONTRACTOR LICENSE NUMBER PLANSET-3 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 sKte RNan PS-3CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA AHJ:SANTA ANA BUILDING CODE:2019 CBC ELECTRICAL CODE:2019 CEC FIRE CODE:2019 CBC RESIDENTIAL CODE:2019 CRC VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 31'-6" 11'-2" 16'-8" 16'-4" 09/19/2022 VSE Project Number: U4879.0061.221 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and screw connections to the existing framing. The design of the racking system, racking connections, and all other structural is by others. Mechanical, architectural, and all other nonstructural aspects of the design are by others. Electrical is by others, unless stamped by Dean Levorsen. 123 E. Anahurst Pl 11/10/22 1081695 CONTRACTOR LICENSE NUMBER RESOURCE -1 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 MO&ULE S2EC S*EET RS-1CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 123 E. Anahurst Pl 11/10/22 1081695 CONTRACTOR LICENSE NUMBER RESOURCE - 2 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 INVERTER S2EC S*EET RS-2CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 123 E. Anahurst Pl 11/10/22 1081695 CONTRACTOR LICENSE NUMBER RESOURCE - 3 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 COMBINER BO: S2EC S*EET RS-3CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 123 E. Anahurst Pl 11/10/22 1081695 CONTRACTOR LICENSE NUMBER RESOURCE - 4 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 RAILIN) S2EC S*EET RS-4CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 123 E. Anahurst Pl 11/10/22 1081695 CONTRACTOR LICENSE NUMBER RESOURCE -5 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: 9/14/2022 MJ 3 ANC*OR S2EC S*EET RS-5CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. SOLID STATE ELECTRIC LLC 7787 EASTGATE RD #100 HENDERSON, NV 89011 USA VICTOR LARA 123 EAST ANAHURST PLACE SANTA ANA CALIFORNIA 92707 123 E. Anahurst Pl 11/10/22 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 123 E. Anahurst Pl 11/10/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 4 Yes 4 flashing 4 K2 CrossRail 44-X 563 27 21 6 485 5 123 E. Anahurst Pl 11/10/22 RS1 123 EAST ANAHURST PLACE FRONT OF HOME STANDARD STRING SYSTEM SITE PLAN EX P E D I T E D P E R M I T P R O C E S S F O R P V S Y S T E M S CONTRACTOR NAME. ADDRESS AND PHONE: SITE PLAN FOR SMALL-SCALE, SINGLE-PHASE PV SYSTEMS SITE NAME: VICTOR LARA SITE ADDRESS: 123 EAST ANAHURST PLACE SYSTEM AC SIZE:3.48 DRAWN BY: MJ SIZE 3.48 FSCM NO: DWG NO: 1 REV: 3 CHECKED BY: MJ SCALE DATE: 44818 SHEET: 1 123 E. Anahurst Pl 11/10/22 CONTRACTOR NAME. ADDRESS AND PHONE: SITE PLAN FOR SMALL-SCALE, SINGLE-PHASE PV SYSTEMS SITE NAME:VICTOR LARA SITE ADDRESS:123 EAST ANAHURST PLACE SYSTEM AC SIZE:3.48 DRAWN BY: MJ SIZE 3.48 FSCM NO:DWG NO: 1 REV:3 CHECKED BY: MJ SCALE DATE:44818 SHEET:1 STANDARD STRING SYSTEM SITE PLAN EX P E D I T E D P E R M I T P R O C E S S F O R P V S Y S T E M S CONDUIT AND CONDUCTOR SCHEDULE TAG DESCRIPTION OR CONDUCTOR TYPE COND. NUMBER OF CONDUIT CONDUIT GAUGE CONDUCTOR TYPE SIZE 1 USE-2 √ OR PV WIRE 12 2 N/A N/A BARE COPPER EQ. GRD. COND. (EGC)6 1 N/A N/A 2 THWN-2 √ OR XHHW-2 OR RHW-2 10 4 EMT OR EQUIVALENT / NM-B CABLE OR UF-B / FLEX 3 THWN-2 √ OR XHHW-2 OR RHW-2 10 2 0 3/4" INTERIOR USE INSULATED EGC 10 3 0 4 DC GROUNDING ELECTRODE COND.10 10 EMT OR EQUIVALENT 3/4" 5 THWN-2 √ OR XHHW-2 OR RHW-2 10 1 0 0 INSULATED EGC EQUIPMENT SCHEDULE TAG DESCRIPTION PART NUMBER NOTES 1 SOLAR PV MODULE SILFAB - 370 NX 2 PV ARRAY 1 3 J-BOX (IF USED) 2IH5-2 4 COMBINER (IF USED) X-IQ-AM1-240-4 5 DC DICSONNECT 6 DC/AC INVERTER SE3800-US 7 GEN METER (IF USED) 8 AC DISCONNECT (IF USED) DG222URB 9 SERVICE PANEL EATON 240 VAC, 125 A MAIN, 125 A BUS, A INVERTER OCPD (SEE NOTE 5 FOR INVERTER OCPDs, ALSO SEE GUEID SECTION 9) INVERTER OCPD BUILDING GROUDING ELECTRODE DISREGARD IF PROVIDED WITH INVERTER FOR UNUSED SERIES STRINGS PUT "N/A" IN BLANK ABOVE SEE GUIDE APPENDIX C FOR INFORMATION ON MODULE AND ARRAY GROUNDING 12MODULES IN SERIES SOURCE-CIRCUIT ----MODULES IN SERIES SOURCE-CIRCUIT ----MODULES IN SERIES SOURCE-CIRCUIT ----MODULES IN SERIES SOURCE-CIRCUIT AC DC 1 2 3 4 5 6 7 8 9 M 1 2 3 4 5 M COMBINERJ-BOX DC DISCO INVERTER AC DISCO MAIN OCPD 123 E. Anahurst Pl 11/10/22 STANDARD STRING SYSTEM SITE PLAN EX P E D I T E D P E R M I T P R O C E S S F O R P V S Y S T E M S NOTES FOR ALL DRAWINGS: OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE REFERENCES SHOWN AS (NEC XXX.XX) 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP 8.3°C 2.) highest continuous ambient temperature based on ashrae highest moth 2% dry bulb temperature for ashrae location most similar to installation location. highest continuous temperature 27°C 3.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURE DO NOT EXCEED 47%°C IN THE UNITED STATES (PAL SPRINGS, CA IS 44.1°C) FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST .05" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE FO 47°C OR LESS (ALL OF THE UNITED STATES A) 12 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH ISC OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. B) 10 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH ISC OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (GUIDE SECTION 6 AND 8 AND APPENDIX D): 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENTS? YES NO N/A√ 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A √ 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (SEE GUIDE SECTION 9) 5) TOTAL OF 1 INVERTER OCPD(S), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(A)? YES √ NO NOTES FOR INVERTER CIRCUITS (GUIDE SECTION 8 AND 9): PHOTOVOLTAIC POWER SOURCE RATED IMPP CURRENT A RATED IMPP VOLTAGE V MAX SYSTEM VOLTAGE V MAX CIRCUIT CURRENT A WARNING: ELECTRICAL SHOT HAZARD-LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION SOLAR PV SYSTEM AC POINT OF CONNECTION AC OUTPUT CURRENT 60A NOMINAL AC VOLTAGE 240V THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) SIGN FOR DC DISCONNECT SIGNS-SEE GUIDE SECTION 7 CONTRACTOR NAME. ADDRESS AND PHONE: SITE PLAN FOR SMALL-SCALE, SINGLE-PHASE PV SYSTEMS SITE NAME: VICTOR LARA SITE ADDRESS: 123 EAST ANAHURST PLACE SYSTEM AC SIZE:3.48 DRAWN BY: MJ SIZE 3.48 FSCM NO: DWG NO: 1 REV: 3 CHECKED BY: MJ SCALE DATE: 44818 SHEET: 1 PV MODULE RATING @ STC (GUIDE SECTION 5) MODULE MAKE SILFAB - 370 NX MODULE MODEL SILFAB - 370 NX MAX PWER-POINT CURRENT (IMP) 20A MAX POWER-POINT VOLTAGE (VMP) 1000V OPEN-CIRCUIT CURRENT (VOC) 40.8V SHORT-CIRCUIT CURRENT (ISC) 11.51A MAX SERIES FUSE (ISC) 25A MAXIMUM POWER (PMAX) 370 MAX VOLTAGE (TYP 600VDC) 34.06V VOC TEMP COEFF (mV/°C OR %/°C√) -0.29 INVERTER RATING (GUIDE SECTION 4) INVERTER MAKE SE3800-US INVERTER MODEL SE3800-US MAX DC VOLT RATING 480V MAX POWER @ 40°C 93000W NOMINAL AC VOLTAGE 240V MAX AC CURRENT 25A MAX OCPD RATING 25A 123 E. Anahurst Pl 11/10/22