HomeMy WebLinkAbout1226 W River Ln - Plan05/26/2022 RE: Structural Certification for Installation of Residential Solar Chris Baynes:1226 W River Ln, Santa Ana, CA 92706 Attn: To Whom It May Concern Design Criteria Code 2019 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 15 psf V 95 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of S Tile roofing over roof plywood supported by 2X6 Rafters at 24 inches. The slope of the roof was approximated to be 27 degrees and the allowable maximum rafter span is 8 feet between supports. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com 1226 W River Ln - 2017666907/18/22 Structural Letter for PV Installation Date: 05/26/2022 Job Address: 1226 W River Ln Santa Ana, CA 92706 Job Name: Chris Baynes Job Number: 220526CB Scope of Work Table of Content Sheet 1 Cover 2 Attachment Uplift checks 3 Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2019 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 15 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 95 mph Exposure C References NDS for Wood Construction Sincerely, Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. projects@evengineersnet.com http://www.evengineersnet.com 1226 W River Ln - 2017666907/18/22 Wind Load Cont. 95 mph ASCE 7-16 Figure 26.5-1B C 1.0 ASCE 7-16 Sec 26.8.2 0.85 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 1.00 ASCE 7-16 Table 26.9-1 16.62 psf 27.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1) Zone(2r) Zone(2e)Zone(3) Fig. 30-3-2 GCp=-1.8 -2.2 -2.2 -2.1 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-35.90 -43.87 -43.87 -41.88 GCp=0.7 Figure 30.3-2 P=qh(GCp)(γE)(γa)=10.47 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing= 6 ft 5/16" Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity= 760 lbs Zone Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1) 6 16.5 288.8 222.3 Zone(2r) 6 16.5 348.0 222.3 Zone(2e) 6 16.5 348.0 222.3 Zone(3) 6 16.5 333.2 222.3 Conservative Max= 348.0 < 760 CONNECTION IS OK 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration Risk Category = KZ = Kd = Ke = projects@evengineersnet.com http://www.evengineersnet.com 1226 W River Ln - 2017666907/18/22 Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg= 0 psf Ct = 1.1 Ce = 0.9 Is = 1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1) 0 plf Max Length, L = 8.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT = 24 in Dr = 15 psf 30 plf PvDL = 3 psf 18 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL= 57 plf Mdown= 459 lb-ft Mallowable = Sx x Fb' (wind)= 975 lb-ft > 459 lb-ft OK Load Case: DL+S Ps+ Ppvcos(θ)+PDL= 48 plf Mdown= 384 lb-ft Mallowable = Sx x Fb' (wind)= 975 lb-ft > 384 lb-ft OK Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL= 60.6 plf Max Moment, Mu= 485 lb-ft Mallowable = Sx x Fb' (wind)= 1357 lb-ft > 485 lb-ft OK Pv max Shear= 222.3 lbs Shear, Vu=wL/2+Pv Point Load = 414 lbs Max Shear, Vu=wL/2+Pv Point Load = 414 lb Member Capacity DF-L No.2 2X6 CL CF Ci Cr KF φ λ Fb = 900 psi 1.0 1.3 1.0 1.15 2.54 0.85 0.8 1346 psi Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin = 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 5.5 in Width, b = 1.5 in Cross-Sectonal Area, A = 8.25 in2 Moment of Inertia, I xx = 20.7969 in4 Section Modulus, Sxx = 7.5625 in3 Allowable Moment, M all = Fb'Sxx = 847.9 lb-ft DCR=Mu/Mall = 0.47 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A = 990.0 lb DCR=Vu/Vall = 0.42 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 1226 W River Ln - 2017666907/18/22 Siesmic Loads Check Roof Dead Load 15 psf % or Roof with Pv 30% Dpv and Racking 3 psf Average Total Dead Load 15.9 psf Increase in Dead Load 3.0%OK Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans -Chris Baynes. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 Existing 225A 200A 36 36 Q.PEAK DUO BLK-G10+ 360 IQ8M-72-2-US N/A COVER PROJECT NOTES PROJECT MAP 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 75 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS 12.ALL WORK SHALL BE IN ACCORD WITH THE 2019 CBC, 2019 CEC AND 2017 NEC WITH SPECIAL EMPHASIS ON ARTICLE 690 13. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 14. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC 690.47(C) AND SIZED AS PER SEC 250.122 15. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 16. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS GENERAL NOTES: THIS INSTALLATION SHALL COMPLY WITH THE FOLLOWING CODES: 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA RESIDENTIAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 CALIFORNIA FIRE CODE ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES project description DC SOLAR PHOTOVOLTAIC SYSTEM NUMBER OF SOLAR ARRAYS TYPE OF INVERTERS MAIN SERVICE PANEL CONDUCTORS TYPE CONDUITS TYPE ON ROOF CONDUITS TYPE FROM EQUIPMENT ROOF TYPE ROOF RAFTERS BATTERY SYSTEM MANUFACTURE NUMBER OF BATTERIES additional system info AC CEC SOLAR SYSTEM SIZE NUMBER OF SOLAR MODULES NUMBER OF INVERTERS SOLAR PANEL MODEL NUMBER INVERTERS MODEL NUMBER ADDITIONAL DC OPTIMIZER MAIN SERVICE PANEL BUS MAIN SERVICE PANEL MAIN C/B NUMBER OF ROOF STORY MAIN C/B LOCATION PROPERTY DETAILS APN LIVING AREA LOT AREA PROPERTY TYPE TYPE OF CONSTRUCTION OCCUPANCY GROUP code summary additional notes space (if needed) SPACE FOR STAMP AND ADDITIONAL NOTES FROM PLAN CHECK N FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 3 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT Roof access points shall be located in areas that do not require the placement of ground ladders over openings such as window or doors, and located at strong points of building construction in locations where the access point does not conflict with overhead obstructions such as tree limbs, wires, or signs. 12,960kW 11,793kW 1 1 MICRO THWN-2 EMT EMT 00113619 2,438 sqft 9,147 sqft RESIDENTIAL V-B R-3 70ATOTAL PV SIZE NON CENTER N/A 2X6 24" O/C TILE IRONRIDGE TOTAL ESS SIZE IN AMP N/A MOUNTING SYSTEM N/A TOTAL ESS SYSTEM SIZE N/A Bldg permit#10111033 Elect permit# 20176669 Permits issued on 7/16/22 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 COMBINER BOX 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 SOLAR RACKING DATASHEET 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 SOLAR GROUNDING 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 SOLAR ATTACHMENT 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 certifications 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 MODULE COMPATIBILITY 1226 W River Ln - 2017666907/18/22 Property line 1'-6" 3' 3' 3' PCB MSP (E) Pool ARRAY 1 3'-11 2" 14'-71 2" 79'-9" 5'-31 2" 54'-21 4" Jbox Roof access Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 Existing 225A 200A 36 36 Q.PEAK DUO BLK-G10+ 360 IQ8M-72-2-US IQ8M-72-2-US Q.PEAK DUO BLK-G10+ 360 PLOT PLAN Scale: 1/16" = 1'-0" PV-1 PLOT PLAN Site Plan N PV ARRAY INFORMATION ROOF COVERAGE TOTAL ROOF AREA (SQ.FT.) -4204 SOLAR AREA (SQ.FT.) - 714 % OF COVERED AREA - 17% MAIN SERVICE PANEL-<MSP PV COMBINER BOX-<PCB MAIN AND PV EQUIPMENT INFORMATION (LEGEND) AC DISCONNECT-<ACD SOLAR MODULES AND INVERTER BATTERY MODEL AND #-<BAT OTHER EQUIPMENT INFORMATION (LEGEND) SERVICE SUB PANEL-<SSP ESS COMBINER PANEL-<ECP NEW N/A BUS N/A N/A N/A N/A 3' working clearance in front of equipment is requoired by CEC 110.26 MAIN BREAKER PERFORMANCE METER-<PM N/A RAFTER SIZE 2X6 24" O/C ROOF TYPE TILE ENPOWER SMART SWITCH-<ESW 5 ft clearance is required by the battery manufacturer ARRAY #1 PITCH AZIMUTH PANEL MODEL ADDITIONAL EQUIPMENT 36 36 27 DEG 180 deg W River Ln Structural Only 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 11 11 8 N/A N/A 6 PV-2.1 STRINGING LAYOUT N B.CIRCUIT #1 B.CIRCUIT #2 B.CIRCUIT #3 B.CIRCUIT #5 B.CIRCUIT #6 B.CIRCUIT #4 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 (N) PV BREAKER installed in slot furthest from main breaker #4 FACILITY GROUND AMP NON CENTER MAIN BREAKER MAIN SERVICE PANEL 120/240V, SINGLE PHASE SERVICE MAIN PANEL BUS MAIN BREAKER UTILITY METER 70A 8' minimum embedment rod at 6' from equipment ground conductor unless existing ground is UFER. 225A 225A 200A 200A Existing Existing ENPHASE IQ COMBINER 4 SOLAR-ONLY SUB PANEL 125A BUS, 120/240 VAC ENVOY MONITORING SYSTEM 15A BREAKER 20A 2P PV BREAKER 20A 2P PV BREAKER 3/4" EMT CONDUIT (3) #6 AWG THWN-2 Conductors (1) #8 AWG THWN-2 Ground 20 FEET J BOX NEMA 3R WIRES EXPOSED TO FREE AIR UNDER ARRAY Enphase Q-Cable (2) #12 AWG Conductors (1) #6 AWG Bare Copper Ground BRANCH #1 BRANCH #2 BRANCH #3 BRANCH #4 3/4" EMT CONDUIT (8) #10 AWG THWN-2 Conductors (1) #8 AWG THWN-2 Ground 20A 2P PV BREAKER 20A 2P PV BREAKER 2 FEET IQ8M-72-2-US Q.PEAK DUO BLK-G10+ 360 Q.PEAK DUO BLK-G10+ 360 IQ8M-72-2-US Q.PEAK DUO BLK-G10+ 360 IQ8M-72-2-US Q.PEAK DUO BLK-G10+ 360 IQ8M-72-2-US Q.PEAK DUO BLK-G10+ 360 IQ8M-72-2-US Q.PEAK DUO BLK-G10+ 360 IQ8M-72-2-US 11 11 8 N/A N/A 6 PV-2.2 SINGLE LINE DIAGRAM 1)Equipment is "New" unless otherwise noted. All PV system wires shall be protected against physical damage 2)Terminations shall be rated 75 degree PV PANEL AND EQUIPMENT MODEL NUMBER,QUANTITY B.CIRCUIT #1 B.CIRCUIT #2 B.CIRCUIT #3 B.CIRCUIT #5 B.CIRCUIT #6 B.CIRCUIT #4 (if applicable) (if applicable) (if applicable) (if applicable) (if applicable) ADDITIONAL NOTES 1226 W River Ln - 2017666907/18/22 ROOF ATTACHMENT ROOF SURFACE per attachment detail PV MODULE 4''X12'' Blocking 2" ROOF SUPPORT RAFTERS .2X6 24" O/C Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 RAFTER 3/8" X 3/4" SS Hex Bolt 3/8" SS Flat Washer 1 Layer of 5/16"SS Lag Bolt Min 2.5" Embed into framing Member Threaded Fast Jack BaseRAFTERS .2X6 24" O/C TILE PV-3 ARRAY LAYOUT & DETAILS Roof Attachment FAST JACK on 24" O.C. Rafters ARRAY LAYOUT Scale: 1/8" = 1'-0" N ARRAY MOUNTING CROSS SECTION ROOF ATTACHMENT NOTE: Footing placement is estimated. Exact footing placement tbd by installers at time of install. 27° PV Railing 72" Max Rail Span 24" Max Rail Cantilever Structural Only 1226 W River Ln - 2017666907/18/22 WARNING! ELECTRIC SHOCK HAZARD. DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. PHOTOVOLTAIC SYSTEM AC DISCONNECT OPERATING VOLTAGE: OPERATING CURRENT: 240 VOLTS 48.6 AMPS SOLAR (STICKER LOCATED INSIDE PANEL NEXT TO SOLAR BREAKER) WARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. (STICKER LOCATED INSIDE PANEL BELOW SOLAR BREAKER) 690.56(C)(3) Rapid Shutdown Switch. A rapid shutdown switch shall have a label located on or no more than 1 m (3 ft) from the switch that includes the following wording CAUTION SOLAR CIRCUIT WARNING PHOTOVOLTAIC POWER SOURCE OR (STICKER TO BE LOCATED ON CONDUIT WITH DC CURRENT EVERY 4' HORIZONTALLY OR 10' VERTICALLY AND 1' FROM EACH SIDE OF A BEND) DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM WARNING! ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED CAUTION AUTHORIZED SOLAR PERSONNEL ONLY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY IFC 605.11.3.1(1) & 690.56(C)(1)(a) Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 All system labels and warnings to be installed at the site and their locations in accordance with Article 690 of the 2019 California Electric Code and the Fire Department having jurisdiction Guidelines. The following labeling requirements apply to the "Rapid Shutdown" equipment. 690.56 Identification of Power Sources. (C) Facilities with Rapid Shutdown. Buildings or structures with both utility service and a PV system, complying with 690.12, shall have a permanent plaque or directory including the following wording: PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN The plaque or directory shall be reflective, with all letters capitalized and having a minimum height of 9.5mm, in white on red background. Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacement, exposure, and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background with white lettering. MARKINGS, LABELS, AND WIRING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. B. Main Service Disconnect 1. Residential buildings - The marking shall be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - The marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated. 3. Markings: Verbiage, Format, and Type of Material a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Min 3/8" letter height. All letters capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (as per UL-969). Durable adhesive materials meet this requirement. C. Marking requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners, and junction boxes: 1. Markings: Verbiage, Format, and Type of Material. a. Placement: Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and below penetrations, all DC combiners and junction boxes. b. Verbiage: CAUTION: SOLAR CIRCUIT (Note: the format and type of material shall adhere to "V. V-3b, c" of this requirement.) c. Inverters are not required to have caution markings. 2. Marking is required on all interior and exterior DC conduit, raceways, enclosures, cable assemblies, and junction boxes, combiner boxes, and disconnects. CFC 605.11.1 3. The materials used for marking shall be reflective, weather reflective, weather resistant materials suitable for the environment. Minimum 3/8" letter height; all upper case, Arial or similar font; Red background with white lettering. CFC 605.11.1 4. Marking shall contain the words: WARNING: PHOTOVOLTAIC POWER SOURCE. CFC 605.11.1.2 5. Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated. CFC 605.11.1.3 AC DISCONNECT if applicable SUB-PANEL if applicable PV SUB-PANEL if applicable DC DISCONNECT if applicable INVERTER if applicable J BOX PV ARRAY MAIN SERVICE PANEL STICKER MAP PV-4 CODE REQUIRED PV SIGNAGE 1 2 6 7 8 3 9 105 2 5 3 4 5 6 7 8 9 10 5 6 7 8 9 6 6 7 8 9 10 11 11 2 N FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGH TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH PV EQUIPMENT LOCATED AS SHOWN MAIN SERVICE PANEL YOU ARE HERE SOLAR COMBINER PANEL 12 W River Ln 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 STICKER STICKER MAP installer use only PV SUPERVISOR STICKER N 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 SOLAR MODULE DATASHEET 1226 W River Ln - 2017666907/18/22 Project Information Chris Baynes 1226 W River Ln, Santa Ana, CA 92706 Date: May 20, 2022 SHEET INDEX PV-1 Plot Plan PV-2.1 Stringing PV-2.2 Single line diagram PV-3 Array Layout PV-4 Signage Sheet 5-13 Additional Information Data sheets, Certifications... SOLAR SOURCE INC 2954 E 14TH ST, LONG BEACH, CA 90804 LIC#: 925231, CLASS - C46, C10 Lisense Date 03/31/2023 INVERTER DATASHEET 1226 W River Ln - 2017666907/18/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1226 W River Ln - 2017666907/18/22