Loading...
HomeMy WebLinkAbout1419 S Spruce St - Plan0-Title Scope of work: Solar PV installation, 3.3 kw, 10 modules, 1 inverter PV System Specifications: 3.300kW DC, 3.000kW AC, 2.967kW CEC ACMODULES: (13) APTOS SOLAR DNA-120-MF23-330W INVERTER: (1) (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER Grid-Tied, Module Dimensions 66.29"x39.44"x1.37" INDEX PV-1.0&1.1 PV-2.0 S-1.0 S-1.1 E-1.0 PV-3.0 PD-1.0 PD-1.1 PD-1.2 PD-1.3 PD-1.4 PD-1.5 PD-1.6 PV-1.7 SITE PLAN -1&2 GENERAL NOTES MOUNTING DETAILS STRUCTURAL DETAILS SINGLE LINE DIAGRAM WARNING PLACARDS MODULE SPEC SHEET INVERTER SPEC SHEET OPTIMIZER SPEC SHEET RACKING SPEC SHEET MOUNT SPEC SHEET GROUNDING SPEC SHEET INTEGRATED GROUNDING SPEC SHEET FIRE RATING SPECSHEET 1419 S Spruce St 12/08/21 LarSun 1611 POMONA RD 206 CORONA CA,92880 Attn.: To Whom It May Concern re job: BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704 Design Criteria: Code:2019 CBC ASCE 7-16 Live Load:20 psf Ult Wind Speed:95 mph Exposure Cat:C Ground Snow:0 psf Min Roof Snow: NA AHZ Consulting Engineers Inc. Professional Engineer projects@ahzengineers.com 8/24/2021 The following calculations are for the structural engineering design of the photovoltaic panels and are valid only for the structural info referenced in the stamped plan set. The verification of such info is the responsibility of others. After review, I certify that the roof structure has sufficient structural capacity for the applied PV loads. All mounting equipment shall be designed and installed per manufacturer's approved installation specifications. www.ahzengineers.com 1419 S Spruce St 12/08/21 Date :8/24/2021 Job Code: BERTHA HERNANDEZ 2 of 6 Roof Properties: Roof Type = Roof Pitch (deg) = Mean Roof Height (ft) = Attachment Trib Width (ft) = Attachment Spacing (ft) = Framing Type = Framing Size = Framing OC Spacing (in.) = Section Thickness, b (in.) = Section Depth, d (in.) = Section Modulus, Sx (in.^3) = Moment of Inertia, Ix (in.^4) = Framing Span (ft) = Deflection Limit D+L (in.) = Deflection Limit S or W (in.) = Attachments Pattern = Framing Upgrade = Sister Size = Wood Species = Wood Fb (psi) = Wood Fv (psi) = Wood E (psi) = C D (Wind) = C D (Snow) = CLS = C M = Ct = CL = Ci = CF = Cfu = Cr = F'b_wind (psi) = F'b_snow (psi) = F'v_wind (psi) = F'v_snow (psi) = M_allowable_wind (lb-ft) = M_allowable_snow (lb-ft) = V_allowable_wind (lbs) = V_allowable_snow (lbs) = 725 524 1008 207 729 2053 288 1.15 2857 1.5 1.00 1.15 1.0 1.6 1.15 180 1600000 DF #2 900 Adequate NA 1.64 Fully Staggered 12.3 2.46 3.1 5.4 1.5 3.5 2x4 24 6 Rafter 23 2.75 Shingle 20 Roof 1 www.ahzengineers.com 1419 S Spruce St 12/08/21 Date :8/24/2021 Job Code: BERTHA HERNANDEZ 3 of 6 E' (psi) = Load Calculation: Panels Dead Load (psf) = Roofing Weight (psf) = Decking Weight (psf) = Framing Weight (psf) = Misc. Additional Weight (psf) = Existing Dead Load (psf) = Total Dead Load (psf) = Ultimate Wind Speed (mph) = Directionality Factor, kd = Topographic Factor, kzt = Velocity Press Exp Factor, kz = Ground Elevation Factor, ke = Velocity Pressure, qz (psf) = Array Edge Factor, γE = Solar Equalization Factor, γa = External Pressure Up, GCp_1 = External Pressure Up, GCp_2 = External Pressure Up, GCp_3 = External Pressure Down, GCp = Design Pressure Up, p_1 (psf) = Design Pressure Up, p_2 (psf) = Design Pressure Up, p_3 (psf) = Design Pressure Down, p (psf) = Hardware Checks: Ref. Widthrawal Value, W (lb/in) = (C M = Ct = Ceg = 1.0) C D = Adjusted Widthrawal Value, W' (lb/in) = Lag Penetration, p (in.) = 426 2.5 266 1.6 Lag Screw Checks: Roof 1 16.0 -38.2 -45.6 0.6 -29.4 -2.6 -3.1 1.25 0.64 -2 0.93 1.00 18.2 95 0.85 1.0 Roof 1 Wind Load Calculations: 6.6 9.6 0.6 1.0 3.0 2.0 Dead Load Calculations: 3.0 Roof 1 1600000 www.ahzengineers.com 1419 S Spruce St 12/08/21 Date :8/24/2021 Job Code: BERTHA HERNANDEZ 4 of 6 Allowable Widthrawal Force, W'p (lbs) = Applied Uplift Force (lbs) = Uplift DCR = Ref. Lateral Value, Z (lbs) = (C M = Ct = CΔ = Ceg = 1.0) C D = Adjusted Lateral Value, Z' (lbs) = Applied Laeral Force (lbs) = Angle of Resultant Force, α (deg) = Adjusted Interaction Lateral Value, Z' α (lbs) = Lateral DCR = Roof Framing Checks: LC1: D+S Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC2: D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC3: D+0.75(S+0.6W) Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = Moment DCR = Shear DCR = LC4: 0.6D+0.6W Applied Moment (lb-ft) = Applied Shear (lbs) = Allowable Moment (lb-ft) = Allowable Shear (lbs) = 729 1008 449 146 0.87 0.21 729 1008 635 207 1.00 0.23 729 1008 726 236 0.69 0.16 524 725 118 Force Checks: Roof 1 363 1058 0.02 17 88 0.9 243 0.40 270 1064 -426 www.ahzengineers.com 1419 S Spruce St 12/08/21 Date :8/24/2021 Job Code: BERTHA HERNANDEZ 5 of 6 Moment DCR = Shear DCR = LC1: D+L Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC2: S Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC3: W (Down) Deflection (in.) = Deflection Limit (in.) = Deflection DCR = LC4: W (Up) Deflection (in.) = Deflection Limit (in.) = Deflection DCR = Seismic Check: Wall Weight (psf) = Tributary Wall Area (ft2) = Total Wall Weight (lbs) = Roof Weight (psf) = Roof Area (ft2) = Total Roof Weight (lbs) = Total Existing Weight (lbs) = PV Panel Weight (lbs) = Number of Panels = Total Additional PV Weight (lbs) = (Existing W + Additional W)/(Existing W)-1 = 1% Additional PV Weight: 54 10 545 Weight Increase: 3000 51000 7 2400 15844 66844 0.79 Existing Weight: 17 -1.48 1.89 1.89 0.43 0.00 0.81 0.00 1.89 2.829 0.61 Deflection Checks (Service Level): Roof 1 1.73 0.62 0.14 www.ahzengineers.com 1419 S Spruce St 12/08/21 Date :8/24/2021 Job Code: BERTHA HERNANDEZ 6 of 6 The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability: Existing structure is assumed to have been designed and constructed following appropriate codes at time of erection, and assumed to have appropriate permits. The calculations produced are only for the roof framing supporting the proposed PV installation referenced in the stamped planset and were completed according to generally recognized structural analysis standards and procedures, professional engineering and design experience, opinions and judgements. Existing deficiencies which are unknown or were not observable during time of inspection are not included in this scope of work. All PV modules, racking, and mounting equipment shall be designed and installed per manufacturer's approved installation specifications. The Engineer of Record and the engineering consulting firm assume no responsibility for misuse or improper installation. This analysis is not stamped for water leakage. Framing was determined based on information in provided plans and/or photos, along with engineering judgement. Prior to commencement of work, the contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any discrepancies prior to starting construction. Contractor shall also verify that there is no damaged framing that was not addressed in stamped plans, calculations, and cert letter (where applicable) and notify the Engineer of Record of any concerns prior to starting construction. www.ahzengineers.com 1419 S Spruce St 12/08/21 2 (10)P340 SOLAREDGE OPTIMIZERS (N)APTOS DNA-120-MF23-330W, 330W MODULES 10 MODULES WIRED IN (1) SERIES OF 10 MODULES G (N)JUNCTION BOX OR EQUIV (N)30A AC DISCONNECT AC DC DC DISCO LOAD RATED DC DISCONNECT & AFCI (RAPID SHUTDOWN COMPLIANCE) (N)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH), 3000W INVERTER 13 3 AC DISCONNECT NON FUSED 30A, 120/240V, 2P (E)100A MAIN BREAKER M PV BREAKER AT THE OPPOSITE END OF BUSBAR 20A 2P PV BREAKER EXISTING 120/240V 1PH 60HZ UT I L I T Y GR I D (E)GROUND ELECTRODE (E)100A END FED MAIN PANEL UTILITY:SCE 222013-020647 SINGLE LINE DIAGRAM E-1.0 SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 3300W, AC SYSTEM SIZE - 3000W,CEC SYSTEM SIZE - 2967W CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4"EMT OR EQUIV (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 MODULE SPECIFICATION MODEL APTOS DNA-120-MF23-330W MODULE POWER @ STC 330W OPEN CIRCUIT VOLTAGE:Voc 40.27V MAX POWER VOLTAGE:Vmp 32.91V SHORT CIRCUIT VOLTAGE:Isc 10.51A MAX POWER CURRENT:Imp 10.02A ELECTRICAL NOTES: 1. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 2. BREAKER/FUSE SIZES CONFORMS TO CEC 240.6 CODE SECTION. 3. AC GROUNDING ELECTRODE CONDUCTOR SIZED PER CEC 250.66. 4. AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 690.31(C). 5. AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON CEC 310.15(B)(2)(C). 6. AX. SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7.7. CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE CEC 310.16. 8. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.0(D). 9. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.8(C). NOTE: 1. INVERTER IS UL1741 RATED. 2. EACH OPTIMIZER ARE RAPID SHUTDOWN COMPLIANT INVERTER-1 SPECIFICATIONS MODEL SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) POWER RATING 3000W MAX OUTPUT CURRENT 12.5A CEC WEIGHTED EFFICIENCY 97.5% MAX INPUT CURRENT 9.5A MAX DC VOLTAGE 500V SYSTEM CHARACTERISTICS DC SYSTEM SIZE 3300 W INVERTER STRING VOLTAGE:Vmp 350V MAX INVERTER SYSTEM VOLTAGE: Voc 500V MAX SHORT CIRCUIT CURRENT 15A OPERATING CURRENT 9.43A ELECTRICAL CALCULATION DC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK 1 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.96 X 1 = 38.40A 18.75A <35A 18.75A <38.40A 2 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.96 X 1 = 38.40A 18.75A <35A 18.75A <38.40A AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK 3 12.5 X 1 = 12.50 X 1.25 = 15.63A 40 X 0.96 X 1 = 38.40A 15.63A < 35A 15.63A < 38.40A OPTIMIZER CHARACTERISTICS MODEL P340 MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 48 VDC MAX INPUT CURRENT 11 ADC MAX OUTPUT CURRENT 15 ADC OCPD CALCULATIONS: MAIN PANEL RATING:100A, MAIN BREAKER RATING:100A 120% RULE: (100AX1.2)-100A=20A =>ALLOWABLE BACKFEED IS 20A INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS =12.5x1.25x1=15.63 A =>PV BREAKER = 20A ALLOWABLE BACKFEED 20A =>20A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS 1419 S Spruce St 12/08/21 PD-1.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 MODULE SPECSHEET 1419 S Spruce St 12/08/21 INV AC MSP SITE PLAN -1 PV-1.0 BERTHA HERNANDEZ - 3.300kW DC, 3.000kW AC, 2.967kW CEC AC SITE PLAN -1 PV-1.0 A SITE PLAN -1 SCALE: 1/8" = 1'-0" ELECTRIC CODE CEC 2019 FIRE CODE CFC 2019 RESIDENTIAL CODE CRC 2019 BUILDING CODE CBC 2019 WIND SPEED 95 MPH SNOW LOAD 0 PSF GENERAL INFORMATION PHOTOVOLTAIC ARRAY ON THE ROOF PV-1.0 A1 VICINITY MAP SCALE: NTS CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 CONDUIT RUN 3'-0" FIRE SETBACK (E) MAIN SERVICE PANEL (EXTERIOR) (N) PV INVERTER(EXTERIOR) (N) AC DISCONNECT (EXTERIOR) PATIO -1 1'-6" FIRE SETBACK INDEX INDEX NO. DESCRIPTION SITE PLAN -1&2 GENERAL NOTES MOUNTING DETAILS STRUCTURAL DETAILS SINGLE LINE DIAGRAM WARNING PLACARDS MODULE SPEC SHEET INVERTER SPEC SHEET OPTIMIZER SPEC SHEET RACKING SPEC SHEET MOUNT SPEC SHEET GROUNDING SPEC SHEET INTEGRATED GROUNDING SPEC SHEET FIRE RATING SPECSHEET PV-1.0&1.1 PV-2.0 S-1.0 S-1.1 E-1.0 PV-3.0 PD-1.0 PD-1.1 PD-1.2 PD-1.3 PD-1.4 PD-1.5 PD-1.6 PV-1.7 B 1419 S Spruce St 12/08/21 INVAC MSP SITE PLAN -2 PV-1.1 BERTHA HERNANDEZ - 3.300kW DC, 3.000kW AC, 2.967kW CEC AC SITE PLAN -2 PV-1.1 A SITE PLAN -2 SCALE: 1"=10'-0" PHOTOVOLTAIC ARRAY ON THE ROOF CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 3'-0" FIRE SETBACKPROPERTY LINE DRIVE WAY S S P R U C E S T FENCE DETACHED STRUCTURE PATIO -1 PATIO -2 GATE WALK WAY 1'-6" FIRE SETBACK 93'-8" 55 ' - 5 " 93'-8" 20'-7" 1'-10" 16'-10" 2'-10" TREES B 1419 S Spruce St 12/08/21 GENERAL NOTES PV-2.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 GENERAL NOTES GENERAL NOTES 1. MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC CODE. 5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6. ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING EQUIPMENT LOCATION: 11. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY CEC CODE. 12. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY CEC CODE AND CEC TABLES. 13. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC CODE. 14. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 15. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO CEC APPLICABLE CODES. 16. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE . STRUCTURAL NOTES: 17. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 18. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 19. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 20. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 21. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES: 22. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 23. CONDUCTORS SIZED ACCORDING TO CEC CODE. 24. DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 25. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [CEC CODE]. INTERCONNECTION NOTES: 24. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [CEC CODE] 25. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120% OF BUSBAR RATING [CEC CODE]. 26. WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, PV DEDICATED BACKFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [CEC CODE]. 27. AT MULTIPLE PV OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVER CURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVER CURRENT DEVICE MAY BE EXCLUDED ACCORDING TO CEC CODE. 28. FEEDER TAP INTER CONNECTION (LOAD SIDE) ACCORDING TO CEC CODE 29. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO CEC CODE WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH CEC CODE 30. BACK FEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [CEC CODE]. GROUNDING NOTES: 31. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 32. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO CEC CODE AND MINIMUM CEC TABLE. 33. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH CEC CODE. 34. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC CODE AND MICRO INVERTER MANUFACTURER'S INSTRUCTIONS. 35. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 36. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 37. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [CEC CODE] 38. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC CODE AND NEC CODE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC CODE AND AHJ. 39. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC CODE IN GENERAL AND CEC CODE SPECIFICALLY. 40. DISCONNECTION AND OVER-CURRENT PROTECTION NOTES. 41. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 42. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 43. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [CEC CODE]. LOCATION OF LABEL ACCORDING TO AHJ. 44. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC CODE. 45. MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH CEC CODE. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC CODE AND UL1699B. 1419 S Spruce St 12/08/21 MOUNTING DETAILS S-1.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 AERIAL VIEW S-1.0 B MOUNTING DETAILS SCALE: 1/8" = 1'-0" UPLIFT CALCULATIONS UPLIFT 5446.8 LBS PULL OUT STRENGTH 11070 LBS POINT LOADING 23 LBS MODULES DATA APTOS DNA-120-MF23-330W MODULE DIMS 66.29"x39.44"x1.37" LAG SCREWS 5/16"x3.5":2.5"MIN EMBEDMENT MINIMUM FIRE ACCESS PATHWAYS PER CFC 2019 RIDGE TO ARRAY: 3'-0" EAVE TO ARRAY : 3'-0" HIP/VALLEY W/ ADJACENT ARRAY: 1'-6" EACH SIDE HIP/VALLEY W/O ADJACENT ARRAY: 0'-0" NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. FIRE SETBACK ALUMINIUM RAILS 2 X 4 RAFTERS@ 2'-0"SPACING DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 10 41.9 419.00 MID-CLAMP 14 0.050 0.70 END-CLAMP 12 0.050 0.60 RAIL LENGTH 68 0.680 46.24 SPLICE BAR 0 0.360 0.00 FLASH FOOT 18 1.35 24.30 TOTAL WEIGHT OF THE SYSTEM (LBS)490.84 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)181.56 WEIGHT PER SQ. FT.(LBS)2.70 WEIGHT PER PENETRATION (LBS)27.27 ARRAY MP-01 SITE INFORMATION SR.NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.)ROOF TYPE ATTACHMENT ROOF EXPOSURE FRAME TYPE FRAME SIZE FRAME SPACING MAX RAIL SPAN OVER HANG MP-01 90° 20° 2 36.3 COMPOSITION SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" MP-02 90° 20° 8 145.2 COMPOSITION SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" ARRAY MP-02 3' 6' 1'-6" 1419 S Spruce St 12/08/21 STRUCTURAL DETAILS S-1.1 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 MID-CLAMP & END CLAMP DETAIL GROUNDING DETAILS MID CLAMP ASSEMBLY MODULE FRAME RAIL GROUNDING MID-CLAMP SCALE: NTS MODULE TO MODULE & MODULE TO RAIL GROUNDING RAIL TO RAIL IRON RIDGE RAIL INTERNAL SPLICE SELF-DRILLING SCREW SCALE: NTS T BOLT SCALE: NTS SCALE: NTS MID-CLAMP & END CLAMP DETAIL FLASHFOOT SOLAR MODULE RAIL 6" MAX 2 X 4 RAFTERS@2'-0" SPACING LOAD BEARING WALL ROOF FRAMING DETAIL SCALE: NTS SCALE: NTS ATTACHMENT DETAIL - FLASHFOOT 5/16 HEX-BOLT STAINLESS STEEL 5/16" HANGER BOLT 2.5" EMBEDMENT PILOT HOLE REQUIRED (E)COMPOSITION SHINGLE ROOF IRONRIDGE FLASHFOOT IRONRIDGE RAIL PV MODULE (E) BUILDING STRUCTURE PV MODULE IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE END CLAMP PV MODULE IRONRIDGE RAIL MID CLAMP 1419 S Spruce St 12/08/21 2 (10)P340 SOLAREDGE OPTIMIZERS (N)APTOS DNA-120-MF23-330W, 330W MODULES 10 MODULES WIRED IN (1) SERIES OF 10 MODULES G (N)JUNCTION BOX OR EQUIV(N)30A AC DISCONNECT AC DC DC DISCO LOAD RATED DC DISCONNECT & AFCI (RAPID SHUTDOWN COMPLIANCE) (N)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH), 3000W INVERTER 13 3 AC DISCONNECT NON FUSED 30A, 120/240V, 2P (E)100A MAIN BREAKER M PV BREAKER AT THE OPPOSITE END OF BUSBAR 20A 2P PV BREAKER EXISTING 120/240V 1PH 60HZ UT I L I T Y GR I D (E)GROUND ELECTRODE (E)100A END FED MAIN PANEL UTILITY:SCE 222013-020647 SINGLE LINE DIAGRAM E-1.0 SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 3300W, AC SYSTEM SIZE - 3000W,CEC SYSTEM SIZE - 2967W CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 10 AWG PV WIRE NONE (1) 6 AWG BARE COPPER 2 3/4"EMT OR EQUIV (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 MODULE SPECIFICATION MODEL APTOS DNA-120-MF23-330W MODULE POWER @ STC 330W OPEN CIRCUIT VOLTAGE:Voc 40.27V MAX POWER VOLTAGE:Vmp 32.91V SHORT CIRCUIT VOLTAGE:Isc 10.51A MAX POWER CURRENT:Imp 10.02A ELECTRICAL NOTES: 1. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 2. BREAKER/FUSE SIZES CONFORMS TO CEC 240.6 CODE SECTION. 3. AC GROUNDING ELECTRODE CONDUCTOR SIZED PER CEC 250.66. 4. AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 690.31(C). 5. AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON CEC 310.15(B)(2)(C). 6. AX. SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7.7. CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE CEC 310.16. 8. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.0(D). 9. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.8(C). NOTE: 1. INVERTER IS UL1741 RATED. 2. EACH OPTIMIZER ARE RAPID SHUTDOWN COMPLIANT INVERTER-1 SPECIFICATIONS MODEL SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) POWER RATING 3000W MAX OUTPUT CURRENT 12.5A CEC WEIGHTED EFFICIENCY 97.5% MAX INPUT CURRENT 9.5A MAX DC VOLTAGE 500V SYSTEM CHARACTERISTICS DC SYSTEM SIZE 3300 W INVERTER STRING VOLTAGE:Vmp 350V MAX INVERTER SYSTEM VOLTAGE: Voc 500V MAX SHORT CIRCUIT CURRENT 15A OPERATING CURRENT 9.43A ELECTRICAL CALCULATION DC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK 1 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.96 X 1 = 38.40A 18.75A <35A 18.75A <38.40A 2 1 X 15 X 1 = 15 X 1.25 = 18.75A 40 X 0.96 X 1 = 38.40A 18.75A <35A 18.75A <38.40A AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK 3 12.5 X 1 = 12.50 X 1.25 = 15.63A 40 X 0.96 X 1 = 38.40A 15.63A < 35A 15.63A < 38.40A OPTIMIZER CHARACTERISTICS MODEL P340 MIN INPUT VOLTAGE 8 VDC MAX INPUT VOLTAGE 48 VDC MAX INPUT CURRENT 11 ADC MAX OUTPUT CURRENT 15 ADC OCPD CALCULATIONS: MAIN PANEL RATING:100A, MAIN BREAKER RATING:100A 120% RULE: (100AX1.2)-100A=20A =>ALLOWABLE BACKFEED IS 20A INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS =12.5x1.25x1=15.63 A =>PV BREAKER = 20A ALLOWABLE BACKFEED 20A =>20A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS 1419 S Spruce St 12/08/21 INVAC MSP PV-3.0 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN WARNING ! CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.FASTENERS APPROVED BY THE LOCAL JURISDICTION NOTE:ALL SIGNAGE CANNOT BE HAND WRITTEN CEC 110.21. 1419 S SPRUCE ST, SANTA ANA, CA 92704.WARNING PLACARDS WARNING PLACARDS LABEL LOCATION AC DISCONNECT , DC DISCONNECT,POINT OF INTERCONNECTION (WITH IN 3' FT FROM POINT OF INTERCONNECTION) [PER CODE: CEC690.56(C)(1)] TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN ADC VDC ADC VDC VDC ADC ADC PHOTOVOLTAIC SYSTEM DC DISCONNECT LABEL LOCATION DC DISCONNECT SWITCH, INVERTER-01 [PER. CODE: CEC 690.53] 500 15 15 MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER(IF INSTALLED) PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH VDC ADC ADC VDC ADC ADC WARNING CAUTION: SOLAR CIRCUIT LABEL LOCATION POINT OF INTERCONNECTION (PER CODE: CEC 705.12(2)(b) [ Not Required if Panel board is rated not less than sum of ampere ratings of all overcurrent devices supplying it] WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION CONDUIT, COMBINER BOX [PER CODE: CEC690.31(G)(3)] WARNING-Electric Shock Hazard No User Serviceable Parts inside Contact authorized service provide for assistance LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT [PER CODE: CEC 690.13] LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION [PER CODE: CEC690.13(B)] LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION [PER CODE: CEC 690.54] LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. (PER CODE:CFC605.11.1.4) LABEL LOCATION POINT OF INTERCONNECTION [PER CODE: CEC705.12(D)(4)] ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: CEC 690.13(B)] DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: CEC 690.13(B)] LABEL LOCATION WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. (PWER CODE: CEC690.15 ,690.13(B)) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SOLAR DISCONNECT RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 12.50 240 AMPS AC VAC PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION INVERTER,POINT OF INTERCONNECTION [PER CODE: CEC 690.56(C)(3)] RAPID SHUTDOWN SWITCH FOR SOLAR SYSTEM (E) MAIN SERVICE PANEL (EXTERIOR) PHOTOVOLTAIC ARRAY ON THE ROOF (N) PV INVERTER(EXTERIOR) (N) AC DISCONNECT (EXTERIOR) 1419 S Spruce St 12/08/21 PD-1.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 MODULE SPECSHEET 1419 S Spruce St 12/08/21 PD-1.1 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 INVERTER SPECSHEET 1419 S Spruce St 12/08/21 PD-1.2 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 OPTIMIZER SPECSHEET 1419 S Spruce St 12/08/21 PD-1.3 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 RACKING SPECSHEET 1419 S Spruce St 12/08/21 PD-1.4 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 MOUNT SPECSHEET 1419 S Spruce St 12/08/21 PD-1.5 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 GROUNDING SPECSHEET 1419 S Spruce St 12/08/21 PD-1.6 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 INTEGRATED GROUNDING SPECSHEET 1419 S Spruce St 12/08/21 PD-1.7 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 FIRE RATING SPECSHEET 1419 S Spruce St 12/08/21 PD-1.2 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 OPTIMIZER SPECSHEET 1419 S Spruce St 12/08/21 PD-1.3 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 RACKING SPECSHEET 1419 S Spruce St 12/08/21 PD-1.4 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 MOUNT SPECSHEET 1419 S Spruce St 12/08/21 PD-1.5 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 GROUNDING SPECSHEET 1419 S Spruce St 12/08/21 PD-1.6 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 INTEGRATED GROUNDING SPECSHEET 1419 S Spruce St 12/08/21 PD-1.7 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 FIRE RATING SPECSHEET 1419 S Spruce St 12/08/21 INV AC MSP SITE PLAN -1 PV-1.0 BERTHA HERNANDEZ - 3.300kW DC, 3.000kW AC, 2.967kW CEC AC SITE PLAN -1 PV-1.0 A SITE PLAN -1 SCALE: 1/8" = 1'-0" ELECTRIC CODE CEC 2019 FIRE CODE CFC 2019 RESIDENTIAL CODE CRC 2019 BUILDING CODE CBC 2019 WIND SPEED 95 MPH SNOW LOAD 0 PSF GENERAL INFORMATION PHOTOVOLTAIC ARRAY ON THE ROOF PV-1.0 A1 VICINITY MAP SCALE: NTS CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 CONDUIT RUN 3'-0" FIRE SETBACK (E) MAIN SERVICE PANEL (EXTERIOR) (N) PV INVERTER(EXTERIOR) (N) AC DISCONNECT (EXTERIOR) PATIO -1 1'-6" FIRE SETBACK INDEX INDEX NO. DESCRIPTION SITE PLAN -1&2 GENERAL NOTES MOUNTING DETAILS STRUCTURAL DETAILS SINGLE LINE DIAGRAM WARNING PLACARDS MODULE SPEC SHEET INVERTER SPEC SHEET OPTIMIZER SPEC SHEET RACKING SPEC SHEET MOUNT SPEC SHEET GROUNDING SPEC SHEET INTEGRATED GROUNDING SPEC SHEET FIRE RATING SPECSHEET PV-1.0&1.1 PV-2.0 S-1.0 S-1.1 E-1.0 PV-3.0 PD-1.0 PD-1.1 PD-1.2 PD-1.3 PD-1.4 PD-1.5 PD-1.6 PV-1.7 B Bldg permit#101108827 Elect. permit#20174917 Issued on 12/8/2021 1419 S Spruce St 12/08/21 INVAC MSP SITE PLAN -2 PV-1.1 BERTHA HERNANDEZ - 3.300kW DC, 3.000kW AC, 2.967kW CEC AC SITE PLAN -2 PV-1.1 A SITE PLAN -2 SCALE: 1"=10'-0" PHOTOVOLTAIC ARRAY ON THE ROOF CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 3'-0" FIRE SETBACKPROPERTY LINE DRIVE WAY S S P R U C E S T FENCE DETACHED STRUCTURE PATIO -1 PATIO -2 GATE WALK WAY 1'-6" FIRE SETBACK 93'-8" 55 ' - 5 " 93'-8" 20'-7" 1'-10" 16'-10" 2'-10" TREES B 1419 S Spruce St 12/08/21 GENERAL NOTES PV-2.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 GENERAL NOTES GENERAL NOTES 1. MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC CODE. 5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6. ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING EQUIPMENT LOCATION: 11. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY CEC CODE. 12. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY CEC CODE AND CEC TABLES. 13. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC CODE. 14. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 15. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO CEC APPLICABLE CODES. 16. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE . STRUCTURAL NOTES: 17. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 18. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 19. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 20. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 21. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES: 22. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 23. CONDUCTORS SIZED ACCORDING TO CEC CODE. 24. DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 25. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [CEC CODE]. INTERCONNECTION NOTES: 24. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [CEC CODE] 25. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120% OF BUSBAR RATING [CEC CODE]. 26. WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, PV DEDICATED BACKFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [CEC CODE]. 27. AT MULTIPLE PV OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVER CURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVER CURRENT DEVICE MAY BE EXCLUDED ACCORDING TO CEC CODE. 28. FEEDER TAP INTER CONNECTION (LOAD SIDE) ACCORDING TO CEC CODE 29. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO CEC CODE WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH CEC CODE 30. BACK FEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [CEC CODE]. GROUNDING NOTES: 31. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 32. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO CEC CODE AND MINIMUM CEC TABLE. 33. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH CEC CODE. 34. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC CODE AND MICRO INVERTER MANUFACTURER'S INSTRUCTIONS. 35. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 36. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 37. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [CEC CODE] 38. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC CODE AND NEC CODE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC CODE AND AHJ. 39. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC CODE IN GENERAL AND CEC CODE SPECIFICALLY. 40. DISCONNECTION AND OVER-CURRENT PROTECTION NOTES. 41. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 42. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 43. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [CEC CODE]. LOCATION OF LABEL ACCORDING TO AHJ. 44. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC CODE. 45. MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH CEC CODE. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC CODE AND UL1699B. 1419 S Spruce St 12/08/21 INVAC MSP PV-3.0 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN WARNING ! CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.FASTENERS APPROVED BY THE LOCAL JURISDICTION NOTE:ALL SIGNAGE CANNOT BE HAND WRITTEN CEC 110.21. 1419 S SPRUCE ST, SANTA ANA, CA 92704.WARNING PLACARDS WARNING PLACARDS LABEL LOCATION AC DISCONNECT , DC DISCONNECT,POINT OF INTERCONNECTION (WITH IN 3' FT FROM POINT OF INTERCONNECTION) [PER CODE: CEC690.56(C)(1)] TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN ADC VDC ADC VDC VDC ADC ADC PHOTOVOLTAIC SYSTEM DC DISCONNECT LABEL LOCATION DC DISCONNECT SWITCH, INVERTER-01 [PER. CODE: CEC 690.53] 500 15 15 MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER(IF INSTALLED) PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH VDC ADC ADC VDC ADC ADC WARNING CAUTION: SOLAR CIRCUIT LABEL LOCATION POINT OF INTERCONNECTION (PER CODE: CEC 705.12(2)(b) [ Not Required if Panel board is rated not less than sum of ampere ratings of all overcurrent devices supplying it] WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION CONDUIT, COMBINER BOX [PER CODE: CEC690.31(G)(3)] WARNING-Electric Shock Hazard No User Serviceable Parts inside Contact authorized service provide for assistance LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT [PER CODE: CEC 690.13] LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION [PER CODE: CEC690.13(B)] LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION [PER CODE: CEC 690.54] LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. (PER CODE:CFC605.11.1.4) LABEL LOCATION POINT OF INTERCONNECTION [PER CODE: CEC705.12(D)(4)] ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: CEC 690.13(B)] DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: CEC 690.13(B)] LABEL LOCATION WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. (PWER CODE: CEC690.15 ,690.13(B)) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM SOLAR DISCONNECT RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 12.50 240 AMPS AC VAC PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION INVERTER,POINT OF INTERCONNECTION [PER CODE: CEC 690.56(C)(3)] RAPID SHUTDOWN SWITCH FOR SOLAR SYSTEM (E) MAIN SERVICE PANEL (EXTERIOR) PHOTOVOLTAIC ARRAY ON THE ROOF (N) PV INVERTER(EXTERIOR) (N) AC DISCONNECT (EXTERIOR) 1419 S Spruce St 12/08/21 STRUCTURAL DETAILS S-1.1 CUSTOMER INFORMATION NAME&ADDRESS: APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:12/23/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 MID-CLAMP & END CLAMP DETAIL GROUNDING DETAILS MID CLAMP ASSEMBLY MODULE FRAME RAIL GROUNDING MID-CLAMP SCALE: NTS MODULE TO MODULE & MODULE TO RAIL GROUNDING RAIL TO RAIL IRON RIDGE RAIL INTERNAL SPLICE SELF-DRILLING SCREW SCALE: NTS T BOLT SCALE: NTS SCALE: NTS MID-CLAMP & END CLAMP DETAIL FLASHFOOT SOLAR MODULE RAIL 6" MAX 4 X 8 RAFTERS@3'-7" SPACING LOAD BEARING WALL ROOF FRAMING DETAIL SCALE: NTS SCALE: NTS ATTACHMENT DETAIL - FLASHFOOT 5/16 HEX-BOLT STAINLESS STEEL 5/16" HANGER BOLT 2.5" EMBEDMENT PILOT HOLE REQUIRED (E)COMPOSITION SHINGLE ROOF IRONRIDGE FLASHFOOT IRONRIDGE RAIL PV MODULE (E) BUILDING STRUCTURE PV MODULE IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE END CLAMP PV MODULE IRONRIDGE RAIL MID CLAMP Plan revised on 1/13/22. 1419 S Spruce St 01/13/22 MOUNTING DETAILS S-1.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 AERIAL VIEW S-1.0 B MOUNTING DETAILS SCALE: 1/8" = 1'-0" UPLIFT CALCULATIONS UPLIFT 5446.8 LBS PULL OUT STRENGTH 11070 LBS POINT LOADING 23 LBS MODULES DATA APTOS DNA-120-MF23-330W MODULE DIMS 66.29"x39.44"x1.37" LAG SCREWS 5/16"x3.5":2.5"MIN EMBEDMENT MINIMUM FIRE ACCESS PATHWAYS PER CFC 2019 RIDGE TO ARRAY: 3'-0" EAVE TO ARRAY : 3'-0" HIP/VALLEY W/ ADJACENT ARRAY: 1'-6" EACH SIDE HIP/VALLEY W/O ADJACENT ARRAY: 0'-0" NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. FIRE SETBACK ALUMINIUM RAILS 2 X 4 RAFTERS@ 2'-0"SPACING DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 10 41.9 419.00 MID-CLAMP 14 0.050 0.70 END-CLAMP 12 0.050 0.60 RAIL LENGTH 68 0.680 46.24 SPLICE BAR 0 0.360 0.00 FLASH FOOT 18 1.35 24.30 TOTAL WEIGHT OF THE SYSTEM (LBS)490.84 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)181.56 WEIGHT PER SQ. FT.(LBS)2.70 WEIGHT PER PENETRATION (LBS)27.27 ARRAY MP-01 SITE INFORMATION SR.NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.)ROOF TYPE ATTACHMENT ROOF EXPOSURE FRAME TYPE FRAME SIZE FRAME SPACING MAX RAIL SPAN OVER HANG MP-01 90° 20° 2 36.3 COMPOSITION SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" MP-02 90° 20° 8 145.2 COMPOSITION SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0" 2'-0" ARRAY MP-02 3' 6' 1'-6" 1419 S Spruce St 12/08/21 STRUCTURAL DETAILS S-1.1 CUSTOMER INFORMATION NAME&ADDRESS: 33°43'40.32"N,117°53'19.58"W APN:109-263-05 AHJ:CA-CITY OF SANTA ANA UTILITY:SCE SYSTEM INFORMATION DESIGNER/CHECKED BY: MG/LS PROJECT NUMBER:LARS-003204 SCALE:AS NOTED PAPER SIZE:17"x11" BERTHA HERNANDEZ 1419 S SPRUCE ST, SANTA ANA, CA 92704. ENGINEER OF RECORD DATE:9/30/2021 REV:B DC SYSTEM SIZE : 3300W AC SYSTEM SIZE : 3000W CEC SYSTEM SIZE: 2967W MODULES: (10)APTOS DNA-120-MF23-330W INVERTER: (1)SOLAREDGE TECHNOLOGIES SE3000A-US(240V,1PH) OPTIMIZER: (10) P340 SOLAREDGE OPTIMIZER CONTRACTOR INFORMATION 439 E,HARRISON ST,UNIT E, CORONA, CA 92879. TEL:951-298-9007 LIC:#C46@1043108 MID-CLAMP & END CLAMP DETAIL GROUNDING DETAILS MID CLAMP ASSEMBLY MODULE FRAME RAIL GROUNDING MID-CLAMP SCALE: NTS MODULE TO MODULE & MODULE TO RAIL GROUNDING RAIL TO RAIL IRON RIDGE RAIL INTERNAL SPLICE SELF-DRILLING SCREW SCALE: NTS T BOLT SCALE: NTS SCALE: NTS MID-CLAMP & END CLAMP DETAIL FLASHFOOT SOLAR MODULE RAIL 6" MAX 2 X 4 RAFTERS@2'-0" SPACING LOAD BEARING WALL ROOF FRAMING DETAIL SCALE: NTS SCALE: NTS ATTACHMENT DETAIL - FLASHFOOT 5/16 HEX-BOLT STAINLESS STEEL 5/16" HANGER BOLT 2.5" EMBEDMENT PILOT HOLE REQUIRED (E)COMPOSITION SHINGLE ROOF IRONRIDGE FLASHFOOT IRONRIDGE RAIL PV MODULE (E) BUILDING STRUCTURE PV MODULE IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE END CLAMP PV MODULE IRONRIDGE RAIL MID CLAMP 1419 S Spruce St 12/08/21 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 1419 S Spruce St 12/08/21 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 4 COMPOSITION 4 FLASHING 4 IRONRIDGE FLASHFOOT 465.24 18 25.84 72 181.56 2.56 1419 S Spruce St 12/08/21 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan                                                         :1/8"=1'-0" LARSUN SOLAR 439 E, HARRISON STREET, UNIT E, BERTHA HERNANDEZ CORONA CA 92879. 1419 S SPRUCE ST, SANTA ANA, CA 92704. TEL:951-298-9007 3000W MG LARS-003204 B LS 9/30/2021 PV-1.0 1419 S Spruce St 12/08/21 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram                                                                                                                                                                                                                                                  APTOS SOLAR SOLAREDGE TECHNOLOGIES 240 100 20100 10 N/A N/A N/A 10 2 LARSUN SOLAR 439 E, HARRISON STREET, UNIT E,BERTHA HERNANDEZ 6 1 10 2 EMT 3/4"CORONA CA 92879. 1419 S SPRUCE ST, SANTA ANA, CA 92704.6 3 EMT 3/4"TEL:951-298-9007 10 1 EMT 3/4"3000W 10 1 EMT 3/4" 6 3 EMT 3/4"MG LARS-003204 B 10 1 EMT 3/4"LS 9/30/201 E-1.0 1419 S Spruce St 12/08/21 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date:SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ___ oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) 2 31 1 APTOS 12.5 DNA-120-MF23-330 500 10.02 15 15 10.51 40.27 32.91 20 500 330 3000 350 -0.306 SOLAREDGE TECHNOLOGIES SE3000A-US 12.5 20 240 12.5 LARSUN SOLAR 439 E, HARRISON STREET, UNIT E,BERTHA HERNANDEZ CORONA CA 92879. 1419 S SPRUCE ST, SANTA ANA, CA 92704. TEL:951-298-9007 3000W MG LARS-003204 B LS 9/30/2021 E-1.0 1419 S Spruce St 12/08/21 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1419 S Spruce St LarSun Solar 1043108 Joaquin Malta 661-544-7113 permitting@larsun.com 10/21/2021 1419 S Spruce St 12/08/21