Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1513 S. Garnsey St - Plan
Rev: 11/19/2015 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2013 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Kevin Pham 1513 S. Garnsey St.08/03/22 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 1513 S. Garnsey St.08/03/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 4 4 Flashing 4 24 Composition Shingles g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 Snap N Rack SnapNRack Ultra 565 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for 4 141 maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2217 2.6 1513 S. Garnsey St.08/03/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan 1513 S. Garnsey St.08/03/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram SELECTED IN FIELD SOLAR EDGE INTEGRAL TO INVERTER D22RB,240V,60A,2P,3R NEM 3R n n n SQUARE D OR EQUAL 200 #6 1 5 A St Auburn MA, 01501 12 QUANITY 1 2 SE3800H-USRGM QUANITY 1 US000NNR2 INTEGRAL TO INVERTER 240 200 #10 2 Bright Planet Solar #10 & #6 2& (1)G EMT 3/4"8889974469 # 6 & #8 3 & (1)G EMT 1" 3.8kW/AC 1513 S. Garnsey St.08/03/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNSSEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARDLINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) SOLAR EDGE 39 58 1 n Bright Planet Solar 5 A St Auburn MA, 01501 Mark Talley 8889974469 1000 1000 240 20 15 Duo Blk Ml-G10+395 10.71 36.88 11.1 SE3800H-USRGM 480 16 16 1513 S. Garnsey St.08/03/22 VICINITY MAP A. A LADDER SHALL BE IN PLACE FOR ANY INSPECTIONS IN COMPLIANCE WITH OSHA REGULATIONS. B. PV MODULES ARE NON-COMBUSTIBLE IN NATURE. C. THIS SYSTEM IS A UTILITY INTERACTIVE (GRID CONNECTED) SYSTEM AND DOES NOT HAVE STORAGE BATTERIES (UNLESS SPECIFICALLY INDICATED ON SHEET PV3 & PV3.1). D. A GROUND ELECTRODE SYSTEM WILL BE PROVIDED IN ACCORDANCE WITH CEC 690.47 & 250.50 - 250.166. GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED WHEN BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE GROUNDING SYSTEM. E. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. F. THE EXPOSED METALLIC TABS OF THE SOLAREDGE OPTIMIZERS SHALL BE BONDED AND/OR GROUNDED PER NEC/CEC 690.43(A) AND THE MANUFACTURERS' INSTRUCTIONS. G. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER CEC 110.26. H. ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC, ENGRAVED IN A CONTRASTING COLOR (WHITE). THIS PLAQUE WILL BE PERMANENTLY ATTACHED & UV RESISTANT. I. ALL PLAQUES AND SIGNS WILL BE INSTALLED AS REQUIRED BY 2019 CEC. J. A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL, SHALL BE INSTALLED IN EACH DWELLING WHEN A PERMIT FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDS $1,000.00. A BATTERY POWERED SMOKE DETECTOR SATISFIES THE REQUIREMENTS FOR A SMOKE DETECTOR. APPROVED COMBINED SMOKE ALARMS AND CARBON DIOXIDE ALARMS SHALL BE ACCEPTABLE. A CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN THE SPECIFIC EXISTING DWELLING UNIT THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES FOR WHICH A PERMIT IS ISSUED FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING $1,000.00. LISTED SINGLE- OR MULTI-STATION CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. COMBINED SMOKE/CARBON MONOXIDE ALARMS MAY BE USED. THE ALARM SHALL RECEIVE ITS PRIMARY POWER FROM THE BUILDING WIRING EXCEPT IT IS PERMITTED TO BE SOLELY BATTERY OPERATED WHERE REPAIRS OR ALTERATIONS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHES OR THERE IS NO ACCESS BY MEANS OF AN ATTIC. K. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE AS PER CEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AS BUSBARS WITHIN LISTED EQUIPMENT AS PER CEC 250.64C. L. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THE BUILDING CODE OF THE LOCAL JURISDICTION. M. PV SYSTEMS CONNECTION IN THE SWITCH GEAR (PANEL) SHALL BE POSITIONED AT THE OPPOSITE END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION AS PER CEC 705.12(B)(2)(3)(b). N. ALL EQUIPMENT SUPPLIED SHALL BE UL LISTED OR LISTED BY A LISTING AGENCY RECOGNIZED BY THE STATE IN WHICH THE SYSTEM IS CONSTRUCTED. O. AC DISCONNECTS SHALL BE IN COMPLIANCE WITH CEC 690.17. P. ALL DC CONDUCTORS SHALL BE 90° RATED THHW, THWN-2, USE-2 OR PV WIRE. ALL AC CONDUCTORS SHALL BE 75° RATED THWN WIRE. Q. ANY DC RUNS INSIDE THE BUILDING MUST BE IN METAL CONDUIT AND LABELED EVERY 10'. R. THE UTILITY DISCONNECT HAS VISIBLE BLADES, IS LOCKABLE AND IS ACCESSIBLE TO THE UTILITY 24/7. S. ALL BREAKERS SHALL BE SUITABLE FOR BACK FEED. WHEN BACK FED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION THE BREAKER SHALL NOT READ 'LINE AND LOAD'. T. COORDINATE ANY POWER OUTAGE WITH LOCAL UTILITY AND PROPERTY OWNER. NOTIFY UTILITY BEFORE ACTIVATION OF PV SYSTEM. U. CITY BUILDING INSPECTOR SHALL INSPECT ACCESSIBLE STRUCTURAL CONNECTIONS AND THE HOUSE CURRENT SIDE OF THE SYSTEM, ALL OTHER EQUIPMENT SHALL BE UL LISTED AND APPROVED. V. PHOTOVOLTAIC MODULES SHALL NOT BE INSTALLED OVER ANY ATTIC, PLUMBING OR MECHANICAL VENT. PLUMBING VENTS TO EXTEND A MIN OF 6" ABOVE ROOF OR MODULE. NO BLDG, PLBG OR MECH VENTS TO BE COVERED, OBSTRUCTED OR ROUTED AROUND MODULES. W. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER THE OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT A STRONG POINT OF BUILDING CONSTRUCTION. FIELD VERIFY EXACT LOCATION. X. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIAL OR WASTEWATER GENERATED ON CONSTRUCTION SITE OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. Y. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE AND WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. Z. ALL EQUIPMENT AND CONDUITS SHALL BE PAINTED TO MATCH ITS EXISTING BACKGROUND COLOR OF THAT LOCATION. SYSTEM NOT TO BE ENERGIZED UNTIL APPROVED BY THE LOCAL UTILITY. AA. NO ROOFTOP CONDUIT RUNS, J-BOXES, VENTS, OR OTHER EQUIPMENT OR OBSTRUCTIONS ARE ALLOWED IN THE STATE FIRE MARSHALL'S EDGE SETBACKS, LESS THAN 5' WIDE. CONSTRUCTION NOTES SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:13 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:13 PM TITLE SHEET PV1 BLDG# 10110224 issued 7/30/22 ELEC# 20176014 issued 7/30/22 1513 S. Garnsey St. 08/03/22 EX I S T . EX I S T . EX I ST . EX I S T . EX I S T . EX I ST . EX I S T . EX I S T . EXIST. EX I S T . RO O F A RO O F B SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:25 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:25 PM PV9 JOB HAZARD ANALYSIS JOB HAZARD ANALYSIS SITE NOTES (INCLUDE ANY HAZARD, NUMBERED AND EXPLAINED): CLOSEST URGENT CARE / MEDICAL FACILITY: PUBLIC PROTECTION: EXCLUSION ZONES MARKED ENTRYWAYS FALL PROTECTION: ANCHORS ROPES / CARABINERS & ROPE GRAB HARNESS LANYARDS PPE: SAFETY GLASSES GLOVES HARD HATS ARC FLASH SUIT / HOT GLOVES FIRST AID KIT COVID-19 PPE ON SITE CREW ADHERING TO BPS COVID-19 PLAN DATE: CREW LEAD: CREW MEMBERS: LEGEND EXCLUSION ZONE ELECTRICAL ZONE XXXXXXXXXXXXX L LADDER A ANCHOR ANCHOR WORK ANGLES V VEHICLES HAZARD NUMBER & EXPLAINH# TREE HOME ENTRANCESE 1513 S. Garnsey St.08/03/22 PICKED BY: RECEIVED BY: SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:26 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:26 PM PV10 BOM SHEET 1513 S. Garnsey St.08/03/22 5.1 7 PV MODULES JUNCTION BOX ROOF SIZED DETERMINED IN FIELD 8 9 CONDUIT RUN IS SURFACE MOUNTED (ACTUAL CONDUIT RUNS TO BE DETERMINED IN THE FIELD) 6 OPTIMIZER (TYPICAL FOR EACH MODULE) 10 NOT USED 0' 5' 10' SYMBOL LEGEND = FLUE / PLUMBING VENT = MECHANICAL VENT MAIN SERVICE PANEL AC DISCONNECT UTILITY METER2 1 3 INVERTER & INTEGRATED DC DISCONNECT5 W E S N PV SUB PANEL4 CALIFORNIA FIRE CODE SETBACKS 3' EX I S T . EX I S T . EX I S T . EX I S T . EX I S T . EX I S T . EX I S T . EX I S T . EXIST. EX I S T . RO O F A RO O F B 8 9 76 12 3 5 CEC 110.26 4 5.1 SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:14 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:14 PM ROOF/SITE PLAN PV2 1513 S. Garnsey St.08/03/22 4 2 L1 L2 G N 8.2 9 2 J-BOX 1 MODULES/OPTIMIZERS IN A STRING + - RED BLACK SE SE SE G L1 L2 5 3 L1 L2 G 1 3 10 7.2 N G L1 L2 G N G EXISTING EXISTING INTEGRATED MODULE & RACKING GND METHOD UL 2703 APPROVED 4 EXISTING INVERTER EXISTING UTILITY DISCO REMOVE AT NEW SYSTEM INSTALLATION (NEW) (RELOCATED EXISTING) 5 N G G 8 UTILITYDISCO VISIBLE BLADE LOCKABLE W/UTILITY ACCESS 24/7 11 GND ELECT. NOTE 1 L2 L1 N TO UTILITY GRID 5 SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:17 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:17 PM RISER DIAGRAM PV3 1513 S. Garnsey St.08/03/22 FOR ILLUSTRATION ONLY (NOT ACTUAL MSP) PV SUB PANEL (IF USED) MAIN SERVICE PANEL AC DISCONNECT (IF USED) PLACARD INVERTER CONDUITS/RACEWAYS NOTE: PLAQUES SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH NON CORROSIVE, POP-RIVETS, SCREWS, OR APPROVED ADHESIVE. LOCATION: MAIN PANELCONDUIT, RACEWAYS & ENCLOSURES LOCATION: MAIN SERVICE PANEL & AC DISCONNECT LOCATION: MAIN SERVICE PANEL PV BACK-FED BREAKER LOCATION: MAIN SERVICE PANEL PV BACK-FED BREAKER LOCATION: UTILITY METER LOCATION: PV SUB PANEL (IF USED) 1 5 6 10 1 7 1 9 11 2 3 112 4 8 5 6 11 4 3 2 13 14 13 LOCATION: MAIN SERVICE PANEL / AC DISCONNECT13 LOCATION: AC DISCONNECT14 LOCATION: DC DISCONNECT/INVERTER #17 LOCATION: MAIN SERVICE PANEL8 LOCATION: MAIN SERVICE PANEL LOCATION: INVERTER10 9 SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:20 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:20 PM PV4 EQUIPMENT LABELS 1513 S. Garnsey St.08/03/22 PV4.1 PLACARD PLACARD 12 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SOLAR INVERTER & DC DISCONNECT EXISTING MAIN SERVICE ENTRANCE UTILITY AC DISCO SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:20 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:20 PM 1513 S. Garnsey St.08/03/22 = 3' 6' STRUCTURAL FRAMING MEMBER @ 24" O.C. MIDCLAMP (2 PER MODULE) MOUNT ATTACHMENT RAIL ENDCLAMP, TYP. SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:21 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:21 PM PV5 ATTACHMENT PLAN 1513 S. Garnsey St.08/03/22 8" 1' 2-1/2" 2' or 3' SOLAR MODULE ROOF COVERING IS COMPOSITION SHINGLE OVER PLYWOOD RAIL OPTIMAL SPACING FROM EDGE AND IN BETWEEN CLAMPS LANDSCAPE PANELS PORTRAIT PANELS MODULE CLAMP MODULE CLAMP LAG BOLT NOTE: · SHALL BE AT LEAST 6" FROM ANY TRUSS JOINTS · 5 16" DIAMETER · MINIMUM EMBEDMENT OF 2.5" INTO STRUCTURAL MEMBER </= 6" SNAPNRACK ROOF MOUNT SYSTEM ALL DIMENSIONS IN INCHES SEE PV5 FOR STRUCTURAL INFORMATION **INSTALLER TO VERIFY RAFTER SIZE & SPACING SNAPNRACK SPEEDSEAL MOUNT ·SEALANT APPLIED UNDERNEATH, APPROVED SEALANTS INCLUDE: GEOCELL 2300, GEOCELL 4500, AND CHEMLINK M1 **FIELD TO DETERMINE WHICH SEALANT IS APPROPRIATE BASED ON INSTALL CONDITIONS5 4 3 2 1 ITEM QTY 1 2 3 4 5 PARTS LIST DESCRIPTION 1 SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER / BLACK 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SS 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 1 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR / BLACK 1 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR / BLACK .30 1.86 1.08 1.37 .38 1.00 SLOT 3.05 2.78 1.78 .25 .17 Ø2.24 2.58 3.20 Ø.33 R1.12 R.82 1.21 1.99 1.50 LAG BOLT RAIL SPEEDSEAL MOUNT .30 Ø1.00 4.20 SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:22 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:22 PM PV6 STRUCTURAL COMPONENTS 1513 S. Garnsey St.08/03/22 EX I S T . EX I S T . EX I S T . EX I S T . EX I S T . EX I ST . EX I S T . EX I S T . EXIST. EX I S T . RO O F A RO O F B W E S N SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:23 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:23 PM PV7 PROPERTY LINES PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINEPROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE PROPERTY LINE 1513 S. Garnsey St.08/03/22 EX I ST . EX I S T . EX I S T . EX I S T . EX I ST . EX I S T . EX I S T . EX I S T . EXIST. EX I S T . RO O F A RO O F B SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE: 11/19/2021 10:47:24 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 11/19/2021 10:47:24 PM PV8 OPTIMIZER TRACKING INVERTER(S) SERIAL NUMBERS #_______________________ #_______________________ #_______________________1 2 3 4 5 7 8 9 10 MAPPING INSTRUCTIONS: 12 13 14 15 1. REMOVE THE 'SQUARE' OPTIMIZER STICKER AND PLACE NEATLY ON THE APPROPRIATE NUMBERED SPACE. 2. WRITE THE CORRESPONDING NUMBER ON THE APPROPRIATE MODULE WITHIN THE ARRAY. 17 18 19 20 22 23 24 25 27 28 29 30 32 33 34 35 37 38 39 40 42 43 44 45 6 11 16 21 26 31 36 41 1513 S. Garnsey St.08/03/22 BREAKING THE 20 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new “Quality Controlled PV” of the independent certification institute TÜV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behavior. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. 1 APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings Q.PEAK DUO BLK ML-G10+ 385-405 ENDURING HIGH PERFORMANCE 1513 S. Garnsey St.08/03/22 76.4 in 1940 mm 43.3 in 1100 mm 48.0 in 1220 mm 1656 lbs 751 kg 24 24 32 α [% / K]+0.04 β [% / K] −0.27 γ [% / K]−0.34 NMOT [°F] 109 ± 5.4 (43 ± 3 °C) Hanwha Q CELLS America Inc. 400 Spectrum Center Drive, Suite 1400, Irvine, CA 92618, USA | TEL +1 949 748 59 96 | EMAIL inquiry@us.q-cells.com | WEB www.q-cells.us [V]1000 (IEC) / 1000 (UL) Class II [A DC]20 TYPE 2 [lbs/ft2] 75 (3600 Pa) / 55 (2660 Pa)−40 °F up to +185 °F (−40 °C up to +85 °C) [lbs/ft2] 113 (5400 Pa) / 84 (4000 Pa) 3 See Installation Manual 385 390 395 400 405 [W]385 390 395 400 405 [A]11.04 11.07 11.10 11.14 11.17 [V]45.19 45.23 45.27 45.30 45.34 [A]10.59 10.65 10.71 10.77 10.83 [V]36.36 36.62 36.88 37.13 37.39 [%]≥ 19.6 ≥ 19.9 ≥ 20.1 ≥ 20.4 ≥ 20.6 [W]288.8 292.6 296.3 300.1 303.8 [A]8.90 8.92 8.95 8.97 9.00 [V]42.62 42.65 42.69 42.72 42.76 [A]8.35 8.41 8.46 8.51 8.57 [V]34.59 34.81 35.03 35.25 35.46 53' 40' HC Certified UL 61730 MECHANICAL SPECIFICATION Format 74.0 in × 41.1 in × 1.26 in (including frame) (1879 mm × 1045 mm × 32 mm) Weight 48.5 lbs (22.0 kg) Front Cover 0.13 in (3.2 mm) thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodized aluminum Cell 6 × 22 monocrystalline Q.ANTUM solar half cells Junction Box 2.09-3.98 in × 1.26-2.36 in × 0.59-0.71 in (53-101 mm × 32-60 mm × 15-18 mm), IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 49.2 in (1250 mm), (−) ≥ 49.2 in (1250 mm) Connector Stäubli MC4; IP68 Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © Q C E L L S Q. P E A K D U O B L K M L - G 1 0 + _ 3 8 5 - 4 0 5 _ 2 0 2 1 - 0 5 _ R e v 0 1 _ N A ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) Mi n i m u m Power at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Mi n i m u m Power at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances P MPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power during first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toleranc- es. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m²) TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Maximum Series Fuse Rating Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull3 Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull3 DETAIL A 0.63" (16 mm) 0.33" (8.5 mm)0.96" (24.5 mm) 42.8" (1088 mm) 74.0" (1879 mm) 4 × Mounting slots (DETAIL A) Frame 41.1" (1045 mm) 39.2" (996 mm) 1.26" (32 mm) 8 × Drainage holes 15.6 (395.5 mm) 4 × Grounding points ø 0.18" (4.5 mm) Label ≥49.2" (1250 mm) ≥49.2" (1250 mm) RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P OW E R [ % ] YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 15 5 25200 10 98 86 200 400 600 800 1000 110 100 90 80 RE L A T I V E E F F I C I E N C Y [ % ] IRRADIANCE [W/m²] QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 61730, CE-compliant, Quality Controlled PV - TÜV Rheinland, IEC 61215:2016, IEC 61730:2016, U.S. Patent No. 9,893,215 (solar cells), QCPV Certification ongoing. Horizontal packaging pallets pallets modules 1513 S. Garnsey St.08/03/22 IN V E R T E R S solaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Outdoor and indoor installation Optional: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017, per article 690.11 and 690.12 Extremely small UL1741 SA certified, for CPUC Rule 21 grid compliance Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR WARRANTY 1513 S. Garnsey St.08/03/22 SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Data, ANSI C12.20 Optional(3) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 14-6 AWG 3/4” minimum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -25 to +60(4) (-40˚F / -40˚C option)(5)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated (3) Revenue grade inverter P/N: SExxxxH-US000NNC2 (4) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf (5) -40 version P/N: SExxxxH-US000NNU4 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2018/V01/ENG NAM. Subject to change without notice. 1513 S. Garnsey St.08/03/22 Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 25 YEAR WARRANTY PV power optimization at the module-level Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Mitigates all types of module mismatch losses, from manufacturing tolerance to partial shading Flexible system design for maximum space utilization Fast installation with a single bolt Next generation maintenance with module- level monitoring Meets NEC requirements for arc fault protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) Module-level voltage shutdown for installer and firefighter safety solaredge.com PO W E R OP T I M I Z E R 1513 S. Garnsey St.08/03/22 Power Optimizer For North America P320 / P340 / P370 / P400 / P401 / P405 / P485 / P505 Optimizer model (typical module compatibility) P320 (for 60-cell modules) P340 (for high- power 60-cell modules) P370 (for higher- power 60 and 72- cell modules) P400 (for 72 & 96-cell modules) P401 (for high power 60 and 72 cell modules) P405 (for high- voltage modules) P485 (for high- voltage modules) P505 (for higher current modules) INPUT Rated Input DC Power(1)320 350 370 400 485 505 W Absolute Maximum Input Voltage (Voc at lowest temperature)48 60 80 60 125(2)83(2)Vdc MPPT Operating Range 8 - 48 8 - 60 8 - 80 8-60 12.5 - 105 12.5 - 83 Vdc Maximum Short Circuit Current (Isc)11 11.02 11 10.1 11.75 11 14 Adc Maximum DC Input Current 13.75 12.5 14.65 12.5 17.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H)129 x 153 x 27.5 / 5.1 x 6 x 1.1 129 x 153 x 33.5 / 5.1 x 6 x 1.3 129 x 153 x 29.5 / 5.1 x 6 x 1.16 129 x 159 x 49.5 / 5.1 x 6.3 x 1.9 129 x 162 x 59 / 5.1 x 6.4 x 2.3 mm / in Weight (including cables)630 / 1.4 750 / 1.7 655 / 1.5 845 / 1.9 1064 / 2.3 gr / lb Input Connector MC4(3)Single or dual MC4(3)(4)MC4(3) Input Wire Length 0.16 / 0.52 0.16 or 0.9 /0.52 or 2.95(5)0.16 / 0.52 m / ft Output Wire Type / Connector Double Insulated / MC4 Output Wire Length 0.9 / 2.95 1.2 / 3.9 m / ft Operating Temperature Range(6)-40 to +85 / -40 to +185 ˚C / ˚F Protection Rating IP68 / NEMA6P Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the optimizer “Rated Input DC Power ”. Modules with up to +5% power tolerance are allowed (2) NEC 2017 requires max input voltage be not more than 80V (3) For other connector types please contact SolarEdge (4) For dual version for parallel connection of two modules use P485-4NMDMRM. In the case of an odd number of PV modules in one string, installing one P485 dual version power optimizer connected to one PV module. When connecting a single module seal the unused input connectors with the supplied pair of seals (5) Longer inputs wire length are available for use. For 0.9m input wire length order P401-xxxLxxx (6) For ambient temperature above +85°C / +185°F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for more details PV System Design Using a SolarEdge Inverter(7)(8) Single Phase HD-Wave Single phase Three Phase for 208V grid Three Phase for 277/480V grid Minimum String Length (Power Optimizers) P320, P340, P370, P400, P401 8 10 18 P405, P485, P505 6 8 14 Maximum String Length (Power Optimizers)25 25 50(9) Maximum Power per String 5700 (6000 with SE7600-US - SE11400- US) 5250 6000(10)12750(11) W Parallel Strings of Different Lengths or Orientations Yes (7) For detailed string sizing information refer to: http://www.solaredge.com/sites/default/files/string_sizing_na.pdf (8) It is not allowed to mix P405/P485/P505 with P320/P340/P370/P400/P401 in one string (9) A string with more than 30 optimizers does not meet NEC rapid shutdown requirements; safety voltage will be above the 30V requirement (10) For 208V grid: it is allowed to install up to 6,500W per string when the maximum power difference between each string is 1,000W (11) For 277/480V grid: it is allowed to install up to 15,000W per string when the maximum power difference between each string is 2,000W © SolarEdge Technologies Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 08/2021 DS-000044-1.2-NA. Subject to change without notice. 405 1513 S. Garnsey St.08/03/22 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents Rapid shutdown cables Micro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals. Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. DC connection terminals Disconnect here Disconnect here Switch terminal block 1513 S. Garnsey St.08/03/22 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): If the cables at the top are red and black from left to right, connect as shown below. Figure 2: Rapid shutdown cable connected – option 1 If the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected – option 2 6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. Red (+) Black (-) Black (-) DC+ DC- Red (+) with rapid shutdown resistor Black (-) Red (+) Black (-)Red (+) with rapid shutdown resistor DC+ DC- 1513 S. Garnsey St.08/03/22 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 3 Inverter Software Compatibility Check and Upgrade Perform this procedure after activating the inverter [Step 1 in Chapter 5: Commissioning the Installation of the SolarEdge Installation Guide], and before pairing (Step 2 in Chapter 5 of the SolarEdge Installation Guide). To use the rapid shutdown feature, the inverter communication board firmware (CPU) must be: Version 2.0700 or higher, if the CPU version is 2.0xxx Version 3.0700 or higher, if the CPU version is 3.0xxx ► To check the inverter CPU version: 1 Verify that the inverter has been activated using the activation card supplied with the inverter. 2 Press the LCD light button short presses until the screen below is reached. I D : ## # # # # # # # # D S P 1 / 2 : x . x x x x / x . x x x x C PU :0 0 0 2 . 0 7 0 0 C o u n t r y : X X X X X 3 Check the CPU version number. If lower than 2.0700, upgrade the inverter software as described below; otherwise proceed to “Power Optimizer Pairing”. ► To upgrade the inverter software: Use the supplied SD card adapter or the micro-SD card, which can be removed from the adapter, according to the activation card slot on your inverter communication board, labeled . 1 Verity that the AC breaker connected to the inverter is OFF. 2 Open the inverter cover’s six Allen screws and carefully pull the cover horizontally before lowering it, as described in its manual. 3 Insert the card into the card slot on the communication board. If the communication board has an SD card slot, use the supplied SD card adapter. If there is a micro-SD card slot, remove the micro-SD card from the adaptor and insert it. 4 Close the inverter cover and turn the AC on. If upgrade is required (as described above), it starts automatically. 5 Wait for the message "Done" to be displayed on the LCD. 6 Verify the correct version as described above. 7 Remove the card from the inverter and keep it for additional kit installations. Power Optimizer Pairing Pairing at this stage will reprogram the power optimizers to perform rapid shutdown. 1 Verify that the ON/OFF switch at the bottom of the inverter is OFF. 2 Turn ON the AC breaker and the Safety Switch. 3 Perform Pairing as described in Step 2: Pairing, of Chapter 5: Commissioning of the SolarEdge Installation Guide. Enabling Rapid Shutdown There is an option in setup mode to enable the functionality of rapid shutdown. 1 Verify that the ON/OFF switch at the bottom of the inverter is ON. 2 Enter Setup mode by pressing and holding the LCD light button. 3 Select Maintenance Optimizer Conf. Set Rapid Shutdown. NOTE: Whenever replacing, removing or adding a component in the string, perform Pairing and rapid shutdown setting. Troubleshooting If the inverter does not enter production mode and the LCD displays Night Mode, the connection order of the rapid shutdown cables may be incorrect. Recheck the cables and make sure that the rapid shutdown cables connected to the bottom of the switch are reversed relative to the cables connected at the top of the switch (see Figure 2 and Figure 3). 1513 S. Garnsey St.08/03/22 1513 S. Garnsey St.08/03/22 1513 S. Garnsey St.08/03/22 1513 S. Garnsey St.08/03/22 1513 S. Garnsey St.08/03/22 1513 S. Garnsey St.08/03/22 1513 S. Garnsey St.08/03/22 1513 S. Garnsey St.08/03/22 snapnrack.com 877-732-2860 www.snapnrack.com contact@snapnrack.com Resources snapnrack.com/resources Design snapnrack.com/configurator Where to Buy snapnrack.com/where-to-buy SnapNrack UL 2703 Fire Classification As of January 1st, 2015 many jurisdictions are now enforcing codes based upon updates to the International Building Code (IBC) and UL Standards 1703 (modules) and 2703 (mount- ing systems). The language included in the 2012 IBC requires that the combination of roof mounted solar modules and racking components is to be considered a system (IBC Section 1509.7.2). Additionally, it requires that this system shall meet or exceed the fire classifica- tion of the roof assembly. The objective is to ensure that the PV system does not adversely affect the fire rating of the roof. Roof sur- face fire ratings are classified either A, B, or C; Class A being the most resistant to the spread of flame. Since the physical characteristics of the PV module (material, thickness of glass, etc) also potentially af- fect how a fire will act, modules are now tested and assigned a “type” based upon these characteristics and spread of flame test results. There are 15 total module types, Types 1, 2 and 3 represent dif- ferences in the module composition and Types 4 – 15 are the same module compositions as Types 1 – 3 with differing fire test performance. SnapNrack Series 100 has been Certified for a Class A fire rating with Type 1 and Type 2 modules, in accordance with the standards set forth in UL1703/2703 and IBC 2012. In or- der to maintain this classification, the SnapNrack mounting system must be installed per the UL-approved Installation Manual. Because the test was conducted with the modules at 5 inches from the roof surface (worst case scenario), there is no restriction to the standoff height. Attachment 1 is the SnapNrack QIMS File which is accessed through the UL Online Certifica- tion Directory, or available here: SnapNrack QIMS File. The full SnapNrack Series 100 UL Test Report is available by sending requests to appeng@snapnrack.com. February 2015 1513 S. Garnsey St.08/03/22 C E RT I F I C AT E O F C O M PLI AN C E Certificate Number 20180718-E359313 Report Reference E359313-20171106 Issue Date 2018-JULY-18 Bruce Mahrenholz, Director North American Certification Program UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/ Page 1 of 1 Issued to: SUNRUN SOUTH LLC, DBA SNAPNRACK 775 Fiero Ln Suite 200 San Luis Obispo CA 93401 This is to certify that representative samples of Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels Ultra Rail Mounting and Bonding Systems for use with Photovoltaic Modules, consisting of the following components: Ultra Rail, Mid Clamp, X End Clamp, Universal End Clamp, Ultra Rail Splice, Ultra Rail Composition Mount Kits, Standard Standoff for Ultra Rail, Four Hole Standoff for Ultra Rail, Heavy Duty Standoff for Ultra Rail, Metal Roof Base Standoff for Ultra Rail, Ultra Rail Corrugated Block, , Standard Base Seam Clamp for Ultra Rail, Wide Base Seam Clamp for Ultra Rail, Ultra Rail Universal Tile Hook, Ultra Rail Flat Tile Hook, Flat Tile Replacement Kit for Ultra Rail, S Tile Replacement Kit for Ultra Rail, W Tile Replacement Kit for Ultra Rail, Ultra Rail Hanger Bolt Clamp, Ground Lugs, Ultra Rail Skirt Assembly, MLPE Frame Attachment Kit, MLPE Rail Attachment Kit, Smart Clips. Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 2703, Mounting Systems, Mounting Devices, Clamping/Retention Devices, And Ground Lugs for use with Flat- Plate Photovoltaic Modules and Panels. Additional Information: See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. 1513 S. Garnsey St.08/03/22