HomeMy WebLinkAbout1812 S Van Ness Ave - PlanRev: 11/19/2015 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2013 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Kevin Pham 1812 S Van Ness Ave03/14/22 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 1812 S Van Ness Ave03/14/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 4 4 Flashing 4 24 maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 Composition Shingles Snap N Rack SnapNRack Ultra 943 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 4 235 362 2.6 1812 S Van Ness Ave03/14/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan                                                          1812 S Van Ness Ave03/14/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram                                                                                                                                                                                                          SELECTED IN FIELD SOLAR EDGE INTEGRAL TO INVERTER D22RB,240V,60A,2P,3R NEM 3R n n n SQUARE D OR EQUAL                               240 225200 #6 1 5 A St Auburn MA, 01501 QUANITY 20 SE6000H-USRGM QUANITY 1 US000NNR2 INTEGRAL TO INVERTER 10 #10 4 Bright Planet Solar #10 & #6 4& (1)G EMT 3/4"8889974469 # & #10 3 & (1)G EMT 1" 3.8kW/AC 1812 S Van Ness Ave03/14/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) SOLAR EDGE 39 58 1 n Bright Planet Solar 5 A St Auburn MA, 01501 Mark Talley 8889974469 1000 1000 240 Duo Blk Ml-G10+395 10.65 36.62 11.07 480 SE6000H-USRGM 20 15 20 25 1812 S Van Ness Ave03/14/22 VICINITY MAP A. A LADDER SHALL BE IN PLACE FOR ANY INSPECTIONS IN COMPLIANCE WITH OSHA REGULATIONS. B. PV MODULES ARE NON-COMBUSTIBLE IN NATURE. C. THIS SYSTEM IS A UTILITY INTERACTIVE (GRID CONNECTED) SYSTEM AND DOES NOT HAVE STORAGE BATTERIES (UNLESS SPECIFICALLY INDICATED ON SHEET PV3 & PV3.1). D. A GROUND ELECTRODE SYSTEM WILL BE PROVIDED IN ACCORDANCE WITH CEC 690.47 & 250.50 - 250.166. GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED WHEN BONDED AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE FOR A COMPLETE GROUNDING SYSTEM. E. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTION POINTS IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. F. THE EXPOSED METALLIC TABS OF THE SOLAREDGE OPTIMIZERS SHALL BE BONDED AND/OR GROUNDED PER NEC/CEC 690.43(A) AND THE MANUFACTURERS' INSTRUCTIONS. G. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER CEC 110.26. H. ALTERNATE POWER SOURCE PLACARD SHALL BE PLASTIC, ENGRAVED IN A CONTRASTING COLOR (WHITE). THIS PLAQUE WILL BE PERMANENTLY ATTACHED & UV RESISTANT. I. ALL PLAQUES AND SIGNS WILL BE INSTALLED AS REQUIRED BY 2019 CEC. J. A SMOKE DETECTOR, APPROVED AND LISTED BY THE STATE FIRE MARSHAL, SHALL BE INSTALLED IN EACH DWELLING WHEN A PERMIT FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDS $1,000.00. A BATTERY POWERED SMOKE DETECTOR SATISFIES THE REQUIREMENTS FOR A SMOKE DETECTOR. APPROVED COMBINED SMOKE ALARMS AND CARBON DIOXIDE ALARMS SHALL BE ACCEPTABLE. A CARBON MONOXIDE DETECTOR SHALL BE INSTALLED IN THE SPECIFIC EXISTING DWELLING UNIT THAT HAVE ATTACHED GARAGES OR FUEL-BURNING APPLIANCES FOR WHICH A PERMIT IS ISSUED FOR ALTERATIONS, REPAIRS OR ADDITIONS EXCEEDING $1,000.00. LISTED SINGLE- OR MULTI-STATION CARBON MONOXIDE ALARMS SHALL BE INSTALLED OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS AND ON EVERY LEVEL OF A DWELLING UNIT INCLUDING BASEMENTS. COMBINED SMOKE/CARBON MONOXIDE ALARMS MAY BE USED. THE ALARM SHALL RECEIVE ITS PRIMARY POWER FROM THE BUILDING WIRING EXCEPT IT IS PERMITTED TO BE SOLELY BATTERY OPERATED WHERE REPAIRS OR ALTERATIONS DO NOT RESULT IN THE REMOVAL OF WALL AND CEILING FINISHES OR THERE IS NO ACCESS BY MEANS OF AN ATTIC. K. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE AS PER CEC 250-64B. THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AS BUSBARS WITHIN LISTED EQUIPMENT AS PER CEC 250.64C. L. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THE BUILDING CODE OF THE LOCAL JURISDICTION. M. PV SYSTEMS CONNECTION IN THE SWITCH GEAR (PANEL) SHALL BE POSITIONED AT THE OPPOSITE END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION AS PER CEC 705.12(B)(2)(3)(b). N. ALL EQUIPMENT SUPPLIED SHALL BE UL LISTED OR LISTED BY A LISTING AGENCY RECOGNIZED BY THE STATE IN WHICH THE SYSTEM IS CONSTRUCTED. O. AC DISCONNECTS SHALL BE IN COMPLIANCE WITH CEC 690.17. P. ALL DC CONDUCTORS SHALL BE 90° RATED THHW, THWN-2, USE-2 OR PV WIRE. ALL AC CONDUCTORS SHALL BE 75° RATED THWN WIRE. Q. ANY DC RUNS INSIDE THE BUILDING MUST BE IN METAL CONDUIT AND LABELED EVERY 10'. R. THE UTILITY DISCONNECT HAS VISIBLE BLADES, IS LOCKABLE AND IS ACCESSIBLE TO THE UTILITY 24/7. S. ALL BREAKERS SHALL BE SUITABLE FOR BACK FEED. WHEN BACK FED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION THE BREAKER SHALL NOT READ 'LINE AND LOAD'. T. COORDINATE ANY POWER OUTAGE WITH LOCAL UTILITY AND PROPERTY OWNER. NOTIFY UTILITY BEFORE ACTIVATION OF PV SYSTEM. U. CITY BUILDING INSPECTOR SHALL INSPECT ACCESSIBLE STRUCTURAL CONNECTIONS AND THE HOUSE CURRENT SIDE OF THE SYSTEM, ALL OTHER EQUIPMENT SHALL BE UL LISTED AND APPROVED. V. PHOTOVOLTAIC MODULES SHALL NOT BE INSTALLED OVER ANY ATTIC, PLUMBING OR MECHANICAL VENT. PLUMBING VENTS TO EXTEND A MIN OF 6" ABOVE ROOF OR MODULE. NO BLDG, PLBG OR MECH VENTS TO BE COVERED, OBSTRUCTED OR ROUTED AROUND MODULES. W. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER THE OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT A STRONG POINT OF BUILDING CONSTRUCTION. FIELD VERIFY EXACT LOCATION. X. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIAL OR WASTEWATER GENERATED ON CONSTRUCTION SITE OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. Y. ALL WIRING MUST BE PROPERLY SUPPORTED BY DEVICES OR MECHANICAL MEANS DESIGNED AND LISTED FOR SUCH USE AND WIRING MUST BE PERMANENTLY AND COMPLETELY HELD OFF OF THE ROOF SURFACE. Z. ALL EQUIPMENT AND CONDUITS SHALL BE PAINTED TO MATCH ITS EXISTING BACKGROUND COLOR OF THAT LOCATION. SYSTEM NOT TO BE ENERGIZED UNTIL APPROVED BY THE LOCAL UTILITY. AA. NO ROOFTOP CONDUIT RUNS, J-BOXES, VENTS, OR OTHER EQUIPMENT OR OBSTRUCTIONS ARE ALLOWED IN THE STATE FIRE MARSHALL'S EDGE SETBACKS, LESS THAN 5' WIDE. CONSTRUCTION NOTES SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:26 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:26 PM TITLE SHEET PV1 Bldg permit# 101109726 Elect permit#20175615 Permits issued on 3/14/22 1812 S Van Ness Ave03/14/22 ROOF A RO O F C RO O F D RO O F B SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:43 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:43 PM PV9 JOB HAZARD ANALYSIS JOB HAZARD ANALYSIS SITE NOTES (INCLUDE ANY HAZARD, NUMBERED AND EXPLAINED): CLOSEST URGENT CARE / MEDICAL FACILITY: PUBLIC PROTECTION: EXCLUSION ZONES MARKED ENTRYWAYS FALL PROTECTION: ANCHORS ROPES / CARABINERS & ROPE GRAB HARNESS LANYARDS PPE: SAFETY GLASSES GLOVES HARD HATS ARC FLASH SUIT / HOT GLOVES FIRST AID KIT COVID-19 PPE ON SITE CREW ADHERING TO BPS COVID-19 PLAN DATE: CREW LEAD: CREW MEMBERS: LEGEND EXCLUSION ZONE ELECTRICAL ZONE XXXXXXXXXXXXX L LADDER A ANCHOR ANCHOR WORK ANGLES V VEHICLES HAZARD NUMBER & EXPLAINH# TREE HOME ENTRANCESE 1812 S Van Ness Ave03/14/22 PICKED BY: RECEIVED BY: SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:44 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:44 PM PV10 BOM SHEET 1812 S Van Ness Ave03/14/22 7 PV MODULES JUNCTION BOX ROOF SIZED DETERMINED IN FIELD 8 9 CONDUIT RUN IS SURFACE MOUNTED (ACTUAL CONDUIT RUNS TO BE DETERMINED IN THE FIELD) 6 OPTIMIZER (TYPICAL FOR EACH MODULE) NOT USED5.1 10 NOT USED 0' 5' 10' SYMBOL LEGEND = FLUE / PLUMBING VENT = MECHANICAL VENT MAIN SERVICE PANEL AC DISCONNECT UTILITY METER2 1 3 INVERTER & INTEGRATED DC DISCONNECT5 W E S N 4 NOT USED CALIFORNIA FIRE CODE SETBACKS 3' ROOF A RO O F C 8 9 7 6 1 2 3 5 CEC 110.26 RO O F D RO O F B SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:27 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:27 PM ROOF/SITE PLAN PV2 1812 S Van Ness Ave03/14/22 N G G 8 UTILITYDISCO VISIBLE BLADE LOCKABLE W/UTILITY ACCESS 24/7 11 GND ELECT. NOTE 1 L2 L1 N TO UTILITY GRID 4 4 1 J-BOX 1 MODULES/OPTIMIZERS IN A STRING + - RED BLACK SE SE SE 3 MODULES/OPTIMIZERS IN A STRING + - RED BLACK SE SE SE L1 L2 G L1 L2 5 L1 L2 L1 L2 G INTEGRATED MODULE & RACKING GND METHOD UL 2703 APPROVED 2 4 L1 L2 G N 3 28.2 910 SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:32 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:32 PM RISER DIAGRAM PV3 1812 S Van Ness Ave03/14/22 FOR ILLUSTRATION ONLY (NOT ACTUAL MSP) PV SUB PANEL (IF USED) MAIN SERVICE PANEL AC DISCONNECT (IF USED) PLACARD INVERTER CONDUITS/RACEWAYS NOTE: PLAQUES SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH NON CORROSIVE, POP-RIVETS, SCREWS, OR APPROVED ADHESIVE. LOCATION: MAIN PANELCONDUIT, RACEWAYS & ENCLOSURES LOCATION: MAIN SERVICE PANEL & AC DISCONNECT LOCATION: MAIN SERVICE PANEL PV BACK-FED BREAKER LOCATION: MAIN SERVICE PANEL PV BACK-FED BREAKER LOCATION: UTILITY METER LOCATION: PV SUB PANEL (IF USED) 1 5 6 10 1 7 1 9 11 2 3 112 4 8 5 6 11 4 3 2 13 14 13 LOCATION: MAIN SERVICE PANEL / AC DISCONNECT13 LOCATION: AC DISCONNECT14 LOCATION: DC DISCONNECT/INVERTER #17 LOCATION: MAIN SERVICE PANEL8 LOCATION: MAIN SERVICE PANEL LOCATION: INVERTER10 9 SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:38 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:38 PM PV4 EQUIPMENT LABELS 1812 S Van Ness Ave03/14/22 PV4.1 PLACARD PLACARD 12 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN SOLAR INVERTER & DC DISCONNECT EXISTING MAIN SERVICE ENTRANCE UTILITY AC DISCO SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:39 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:39 PM 1812 S Van Ness Ave03/14/22 Table R802.5.1(2) - Continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240 DEAD LOAD = 20 psf RAFTER SPACING (inches) SPECIES AND GRADE Douglas fir-larch SS Douglas fir-larch #1 Douglas fir-larch #2 Douglas fir-larch #3 Him-fir SS Him-fir #1 Him-fir #2 Him-fir #3 Southern Pine SS Southern Pine #1 Southern Pine #2 Southern Pine #3 Spruce-pine-fir SS Spruce-pine-fir #1 Spruce-pine-fir #2 Spruce-pine-fir #3 24 8-3 8-0 7-10 6-2 7-10 7-8 7-3 6-1 8-1 7-10 7-4 5-8 7-8 7-6 7-6 6-1 (feet- inches) 2 x 4 DEAD LOAD = 10 psf 13-0 12-6 11-11 9-1 12-3 12-0 11-5 8-10 12-9 12-3 11-0 8-4 12-0 11-9 11-9 8-10 (feet- inches) 2 x 6 17-2 15-10 15-1 11-6 16-2 15-8 14-8 11-3 16-10 16-2 13-11 10-6 15-10 14-10 14-10 11-3 (feet- inches) 2 x 8 21-10 19-5 18-5 14-1 20-8 19-2 17-10 13-8 21-6 18-11 16-6 12-9 20-2 18-2 18-2 13-8 (feet- inches) 2 x 10 Note b 22-6 21-4 16-3 25-1 22-2 20-9 15-11 Note b 22-6 19-6 15-1 24-7 21-0 21-0 15-11 (feet- inches) 2 x 12 Maximum rafter spans* 8-3 7-5 7-0 5-4 7-10 7-4 6-10 5-3 8-1 7-5 6-4 4-11 7-8 6-11 6-11 5-3 (feet- inches) 2 x 4 13-0 10-10 10-4 7-10 12-3 10-9 10-0 7-8 12-9 11-1 9-6 7-3 12-0 10-2 10-2 7-8 (feet- inches) 2 x 6 16-10 13-9 13-0 10-0 16-2 13-7 12-8 9-9 16-10 14-0 12-1 9-1 15-4 12-10 12-10 9-9 (feet- inches) 2 x 8 16-9 15-11 12-2 19-10 16-7 15-6 11-10 20-10 16-5 14-4 11-0 18-9 15-8 15-8 11-10 (feet- inches) 2 x 10 23-10 19-6 18-6 14-1 23-0 19-3 17-11 13-9 24-8 19-6 16-10 13-1 21-9 18-3 18-3 13-9 (feet- inches) 2 x 12 13-0 20-7 = 3' 6' STRUCTURAL FRAMING MEMBER @ 24" O.C. MIDCLAMP (2 PER MODULE) MOUNT ATTACHMENT RAIL ENDCLAMP, TYP. 2' 6' STRUCTURAL FRAMING MEMBER @ 24" O.C. MIDCLAMP (2 PER MODULE) MOUNT ATTACHMENT RAIL ENDCLAMP, TYP. SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:40 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:40 PM PV5 ATTACHMENT PLAN 1812 S Van Ness Ave03/14/22 8" 1' 2-1/2" 2' or 3' SOLAR MODULE ROOF COVERING IS COMPOSITION SHINGLE OVER PLYWOOD RAIL OPTIMAL SPACING FROM EDGE AND IN BETWEEN CLAMPS LANDSCAPE PANELS PORTRAIT PANELS MODULE CLAMP MODULE CLAMP LAG BOLT NOTE: · SHALL BE AT LEAST 6" FROM ANY TRUSS JOINTS · 5 16" DIAMETER · MINIMUM EMBEDMENT OF 2.5" INTO STRUCTURAL MEMBER </= 6" SNAPNRACK ROOF MOUNT SYSTEM ALL DIMENSIONS IN INCHES SEE PV5 FOR STRUCTURAL INFORMATION **INSTALLER TO VERIFY RAFTER SIZE & SPACING SNAPNRACK SPEEDSEAL MOUNT ·SEALANT APPLIED UNDERNEATH, APPROVED SEALANTS INCLUDE: GEOCELL 2300, GEOCELL 4500, AND CHEMLINK M1 **FIELD TO DETERMINE WHICH SEALANT IS APPROPRIATE BASED ON INSTALL CONDITIONS5 4 3 2 1 ITEM QTY 1 2 3 4 5 PARTS LIST DESCRIPTION 1 SNAPNRACK, SPEEDSEAL FOOT, BASE, SEALING, SILVER / BLACK 1 BOLT, FLANGE, SERRATED, 5/16IN-18 X 2IN, SS 1 SNAPNRACK, RL UNIVERSAL, MOUNT SPRING, SS 1 SNAPNRACK, ULTRA RAIL MOUNT THRU PRC, CLEAR / BLACK 1 SNAPNRACK, ULTRA RAIL MOUNT TAPPED PRC, CLEAR / BLACK .30 1.86 1.08 1.37 .38 1.00 SLOT 3.05 2.78 1.78 .25 .17 Ø2.24 2.58 3.20 Ø.33 R1.12 R.82 1.21 1.99 1.50 LAG BOLT RAIL SPEEDSEAL MOUNT .30 Ø1.00 4.20 SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:41 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:41 PM PV6 STRUCTURAL COMPONENTS 1812 S Van Ness Ave03/14/22 ROOF A RO O F C RO O F D RO O F B W E S N SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:41 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:41 PM PV7 PROPERTY LINES PR O P E R T Y LI NE PR O P E R T Y LI NE PROPERTY LINE PROPERTY LINEPROPERTY LINE PR O P E R T Y LI NE PR O P E R T Y LI NE PROPERTY LINE PROPERTY LINE PROPERTY LINE 1812 S Van Ness Ave03/14/22 ROOF A RO O F C RO O F D RO O F B SHEET TITLE SHEET # PROJECT # SYSTEM SIZE DESIGNER: DATE:2/9/2022 7:56:42 PM REV DATE ---- DESCRIPTION ---- ---- ---- ---- ----DATE: BRIGHT PLANET SOLAR 103A MILLBURY ST, AUBURN MA 01501 888-997-4469 SIGNATURE: CONTRACTOR LICENSE: C-10#1020761 2/9/2022 7:56:42 PM PV8 OPTIMIZER TRACKING INVERTER(S) SERIAL NUMBERS #_______________________ #_______________________ #_______________________1 2 3 4 5 7 8 9 10 MAPPING INSTRUCTIONS: 12 13 14 15 1. REMOVE THE 'SQUARE' OPTIMIZER STICKER AND PLACE NEATLY ON THE APPROPRIATE NUMBERED SPACE. 2. WRITE THE CORRESPONDING NUMBER ON THE APPROPRIATE MODULE WITHIN THE ARRAY. 17 18 19 20 22 23 24 25 27 28 29 30 32 33 34 35 37 38 39 40 42 43 44 45 6 11 16 21 26 31 36 41 1812 S Van Ness Ave03/14/22 1812 S Van Ness Ave03/14/22