SOLAR PHOTOVOLTAIC SYSTEM NOTES
1. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING
REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS, CEC 110.2, 110.3, 690.4(B) AND 690.12(D).
2. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES.
3. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250.
4. ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT PER CEC 690.9.
5. DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY
ACCESSIBLE LOCATION NEAR THE EQUIPMENT, CEC 690.13, 690.15.
6. ENERGY STORAGE SYSTEMS TERMINALS LOCATED MORE THAN 5 FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM CONNECTED
EQUIPMENT MUST HAVE DISCONNECTING MEANS IN ACCORDANCE WITH CEC 706.7(E) AND LABELED PER 706.7(D). A SECOND
DISCONNECTING MEANS LOCATED AT THE CONNECTED EQUIPMENT SHALL BE INSTALLED WHERE THE DISCONNECTING MEANS AT
THE ESS END OF THE CIRCUIT IS NOT WITHIN SIGHT.
7. RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12.
8. THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL
PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE
ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, CEC 705.40.
9. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR
THE APPLICATION. CEC310.10(D) AND 690.31(C) THROUGH (F).
10. INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS, CEC 690.31(C).
11. FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC 110.14.
12. ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION, CEC 690.31(B).
13. ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC 200.6,
200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH INSULATION OF
GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER
THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C).
14. MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, CEC 705.31.
15. CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION
EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, CEC 705.12(B).
16. DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS, CEC
690.31(G).
17. METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND
MUST BE BONDED IN ACCORDANCE WITH CEC 250.97.
18. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS, CEC 314.15
19. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE
IDENTIFIED AND LISTED FOR SUCH USE, CEC 690.31(H) & 110.14.
20. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT
OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT
INTERRUPTING”, CEC 690.33(C) & (E)(2).
21. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE
BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C).
22. THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, CEC 705.32.
23. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE
PROTECTED, CEC 300.4.
24. PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY
COMPANY.
25. FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD WATER MUST
BE PROVIDE, CEC 250.104.
26. GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH
SOIL, CEC 250.52(A)(5), 250.53(G).
27. MINIMUM 7/8’’ CLEARANCE FROM ROOF TO BOTTOM OF CONDUIT OR USE A TEMPERATURE ADDER OF 33 DEGREES C.
CEC 310.15(B)(3)(C)
28. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED OR
BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM.
29. EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE PROPOSED
MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE MODULES, CPC 906.1.
30. EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE
EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1).
31. THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10' O.C.;
AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, CEC 690.31(G)(4).
32. PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS ONLY
NO LOADS ARE TO BE CONNECTED.
33. WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, CEC 110.26.
34. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND EXTENDING 3'
ABOVE THE ROOF.
35. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS.
36. LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN WHITE ON A
RED BACKGROUND. CEC 690.31(G)(4)
37. IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C).
38. WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO INDICATE
THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT.
39. PANELS AND MODULES NOT TO BE INSTALLED ON ROOF BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. CRC R324.6.2.2
40. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF 5-FEET
MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES, CRC R324.7 & R302.1.
41. PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY.
42. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE.
43. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD
VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL
BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS
ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. R314.1, R315.1
44. ROOF ACCESS POINTS. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF
GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING
CONSTRUCTION IN LOCATIONS WHERE THE ACCESS DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS
TREE LIMBS, WIRES OR SIGNS (R331.4.1).LADDERS SHALL BE OSHA APPROVED AND SECURED TO THE STRUCTURE FOR
INSPECTION PURPOSES.CONTRACTORS ARE REQUIRED TO BE PRESENT FOR THE FIRST AND/OR FINAL INSPECTIONS.
45. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM.
8.075 DC KW SOLAR PV AC MODULE SYSTEM- ROOF MOUNT
BARKER RESIDENCE
2014 NORTH FLOWER ST, SANTA ANA, CA 92706
APPLICABLE CODES
ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL
COMPLY WITH THE FOLLOWING APPLICABLE CODES
2019 CA BUILDING CODES (CBC)
2019 CA RESIDENTIAL CODES (CRC)
2019 CA MECHANICAL CODES (CMC)
2019 CA PLUMBING CODES (CPC)
2019 CA FIRE CODES (CFC)
2019 CA ELECTRICAL CODES (CEC)
2019 CA ENERGY CODES (CEnC)
2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen)
PROJECT SITE
VICINITY MAP
AERIAL VIEW
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
PROJECT SCOPE
INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM
NEW
EQUIPMENT:19 SPR-M425-H-AC
SUNPOWER AC MODULES
19 SPR-M425-H-AC (240V) [Sl1]
SUNPOWER INVERTERS
SYSTEM SIZE: 8.075 DC kW RATING
7.296 CEC AC RATING
SERVICE: EXISTING 200A MAIN SERVICE PANEL
ARRAY AREA: 20.78 SQFT X 19 = 394.82 SQFT
SHEET INDEX
A0 PROJECT INFO, VICINITY MAP, NOTES
A1 SITE PLAN
A2 MOUNTING PLAN
A3 MOUNTING DETAILS
E1 SINGLE LINE DIAGRAM
E2 ELECTRICAL CALCULATIONS
E3 REQUIRED SIGNAGE
E4 AC MODULE DATA SHEET
S1 MOUNTING DATA SHEET
S2 RACKING DATA SHEET
S3 RACKING GROUNDING
S4 RACKING CERTIFICATION
www. Loyd W Martin .com
Solar Structures Engineering
#2022-3209 Structural Only August 09, 2022
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
***HISTORIC PROPERTY***
Bldg #101111890
Elect #20177292
Permits issued on 9/12/22
Plng ok per P. Gomez
2014 N Flower St
09/12/22
RACKING
DATA SHEET
S2
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
2014 N Flower St
09/12/22
GROUNDING
METHOD
S3
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
2014 N Flower St
09/12/22
RACKING
CERTIFICATION
S4
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
2014 N Flower St
09/12/22
SITE PLAN
A1
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
NOTE:
FOR FIRE SETBACKS, FIRE ACCESS
POINTS, CONDUIT ROUTES AND
LOCATION OF THE JUNCTION BOXES
AND RACKING INFORMATION, PLEASE
REFER TO PAGE A-2 MOUNTING PLAN
PROPERTY LINE
SITE PLAN
SCALE: 1/16" = 1'
LEGEND:
(E) - EXISTING
(N) - NEW
NO
R
T
H
F
L
O
W
E
R
S
T
R
E
E
T
(E) DRIVEWAY
(E) POOL
(E) 200A MAIN
SERVICE PANEL
(N) 125A PV
SUBPANEL
(N) 19 - SPR-M425-E-AC
SUNPOWER AC MODULES
(N) 19 - SPR-M425-E-AC(240V)
[SI1] SUNPOWER INVERTERS
(N) 30A AC
DISCONNECT
www. Loyd W Martin .com
Solar Structures Engineering
#2022-3209 Structural Only
August 09, 2022
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2014 N Flower St
09/12/22
C C C C C C C
A
A
A
A
A
B
B
B
B
B
B
A
MOUNTING
PLAN
A2
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
MOUNTING PLAN
SCALE: 1" = 10'
LEGEND:
(E) - EXISTING
(N) - NEW
- CONDUIT RUN
- JUNCTION BOX
- MAIN SERVICE PANEL
- SUBPANEL
JB
MSP
SP
CIRCUIT A - 6 MODULES/MICROS
CIRCUIT B - 6 MODULES/MICROS
CIRCUIT C - 7 MODULES/MICROS
FIRE ACCESS POINT AREA
NOT TO BE OVER ANY
DOORS, WINDOWS OR
OTHER OBSTRUCTIONS
FIRE ACCESS POINT AREA
NOT TO BE OVER ANY
DOORS, WINDOWS OR
OTHER OBSTRUCTIONS
(N) 19 - SPR-M425-E-AC
SUNPOWER AC MODULES
(N) 19 - SPR-M425-E-AC(240V)
[SI1] SUNPOWER INVERTERS
3'
3'
3' PATHWAY
PER R324.6.1
3' PATHWAY
PER R324.6.1
3'
FIRE
SETBACK
3'
FIRE
SETBACK
18"
FI
R
E
S
E
T
B
A
C
K
MSP SP
D
(N) 30A AC
DISCONNECT
EXISTING
CONDUIT
(N) 125A PV
SUBPANEL
(E) 200A MAIN
SERVICE PANEL
JB
JB
3/4" EMT CONDUIT RUN ABOVE
ROOF OR UNDER EAVES WHERE
POSSIBLE WIRING / CONDUIT
RACEWAY WILL BE 7/8'' MINIMUM
ABOVE THE ROOFTOP PER CEC
310.15(B)(3)(c)
INVISIMOUNT
ROW-TO-ROW
GROUNDING
CLIPS
32 TOTAL
ATTACHMENTS
@ 6FT OC MAX
270° AZIMUTH
24° SLOPE
180° AZIMUTH
24° SLOPE
270° AZIMUTH
24° SLOPE
G G
6 FT
APART MIN
2 GROUND
RODS WITH #6
GROUNDING
www. Loyd W Martin .com
Solar Structures Engineering
#2022-3209 Structural Only
August 09, 2022
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2014 N Flower St
09/12/22
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
ROOF INFO
ROOFING: COMP SHINGLE - 1 LAYER
YEAR BUILT: 1941
ROOF PITCH: 24°
ROOF FRAME MEMBERS: 2 X 4 RAFTERS
ON CENTER SPACING: 24"
RAFTER SPAN: 6'
MAX ATTACHMENT SPACING O.C: 72"
MODULES COVER 18.1 % OF THE
ROOF AREA LESS THAN 33% (CRC 324.6.2)
ROOF ATTACHMENT DETAIL
SCALE: NOT TO SCALE
NOTE:
MODULES WILL BE INSTALLED
FLUSHED TO EXISTING ROOF SLOPE
SOLAR PANEL DEAD WEIGHT CALCULATION
RACKING MANUFACTURER INVISIMOUNT RACKING
MODULE SUNPOWER SPR-M425-H-AC
TOTAL # OF MODULES 19 MOUNTING SYSTEM WEIGHT 72.00 LBS
MODULE WEIGHT 48.0 LBS TOTAL MODULES WEIGHT 912.00 LBS
MODULES LENGTH 73.7 INCHES TOTAL SYSTEM WEIGHT 984.00 LBS
MODULES WIDTH 40.6 INCHES POINT LOAD CALCULATION 30.75 LBS
MODULES AREA 20.78 SQFT TOTAL SOLAR MODULE AREA 394.81 SQFT
TOTAL # OF ATTACHMENTS 32 DISTRIBUTED LOAD CALCULATION
THE POINT LOADING AND DISTRIBUTED LOADING
SHOULD BE MAX 5 LBS/FT2
2.49 PSF
RACKING WEIGHT 0.56 LBS/LN FT
ROOF COVERAGE
TOTAL MODULE AREA 394.81 R324.6.2 SET BACK AT RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33
PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN AN 18-INCH (457 MM) CLEAR
SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC
ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT
LESS THAN A 36-INCH (914 MM) CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A
HORIZONTAL RIDGE.
ROOF FACE AREA 2184
ROOF COVERAGE (%)18.1
18.1% < / = 33% = OK
MOUNTING
DETAILS
A3
NOTE:
Engineer of Record assumes that all structural components of the existing
building were permitted and met the requirements of the Building Code at
the time of construction. Solar Contractor shall field verify that the roof
framing is in its existing permitted condition and capable of supporting
required live loads. Framing specified on solar plans shall be assumed to be
minimum size and spacing, actual framing may be different.
www. Loyd W Martin .com
Solar Structures Engineering
#2022-3209 Structural Only
August 09, 2022
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2014 N Flower St
09/12/22
SINGLE LINE
DIAGRAM
E1
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
705.12(B)(2)(3) BUSBARS
(B) WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND
THE OTHER ANOTHER POWER SOURCE, ARE LOCATED AT
OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM
OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT
CURRENT AND THE RATING OF THE OVERCURRENT DEVICE
PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF
THE AMPACITY OF THE BUSBAR. THE BUSBAR SHALL BE SIZED FOR
THE LOADS CONNECTED IN ACCORDANCE WITH ARTICLE 220. A
PERMANENT WARNING LABEL SHALL BE APPLIED TO THE
DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER
FROM THE POWER SOURCE THAT DISPLAYS THE FOLLOWING OR
EQUIVALENT WORDING:
WARNING: POWER SOURCE OUTPUT CONNECTION ? DO NOT
RELOCATE THIS OVERCURRENT DEVICE.
THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH
110.21(B).
NOTE:
TERMINATE LUGS AT 75°
BRANCH CIRCUIT CALCULATION
CIRCUIT
MAX AC
OUTPUT
(AMPS)
# OF
MODULES
RESULT
(AMPS)125%RESULT
(AMPS)
OCPD
SIZE
A 1.60 6 9.60 1.25 12.00 20
B 1.60 6 9.60 1.25 12.00 20
C 1.60 7 11.20 1.25 14.00 20
NOTE:
THE ENPHASE IQ MICROINVERTER SYSTEM USES A
NEW AND IMPROVED CABLING SYSTEM. THE Q CABLE
IS DG TYPE AND CONTAINS ONLY TWO #12 AWG LINE
CONDUCTORS. THE Q CABLE MALE CONNECTORS
PLUG DIRECTLY INTO THE IQ MICROS, WHOSE DOUBLE
INSULATION RATING REQUIRES NO NEUTRAL OR
GROUND CONDUCTORS
(N) JBOX
NEMA 3R
(4) #10
AWG
THWN-2
(2L1, 2L2)
(1) #8 GND
3/4" EMT
CONDUIT
(4) SUNPOWER
AC CABLES
(#12 AWG PV WIRES)
#6 BARE
COPPER (G)M
PV BREAKER MUST BE
INSTALLED AT THE
FARTHEST OPPOSITE END
OF THE MAIN BREAKER
G
N
SOLAR GROUND TYING
INTO EXISTING UFER
GROUND POINT
(N) 125A PV
SUBPANEL
COMBINER
*NO ADDITIONAL LOADS*
(N) 20A
(E) 200A
MSB
(N) 40A
PV OCPD
(3) #8 AWG
THWN-2
(L1, L2, N)
(1) #8 GND
1" EMT
CONDUIT
G
N
240V, 1PHASE, 3W
TOP FED (N) 19 - SPR-M425-E-AC
SUNPOWER AC MODULES
(N) 19 - SPR-M425-E-AC(240V)
[SI1] SUNPOWER INVERTERS
SUM OF CIRCUITS WITH 125%
MAX AC
OUTPUT
(AMPS
TOTAL #
OF
MICROS
TOTAL
MAX AC
OUTPUT
125%RESULT
(AMPS)
OCPD
SIZE
1.60 19 30.40 1.25 38.00 40A
SERVICE LOAD CALCULATIONS
BACKFED 120% RULE - PER 705.12(B)(2)(3)(B)
BUS RATING SIZE MULTIPLIER(120%)RESULT
200 1.20 240.00
MAIN BREAKER INVERTER AC OUTPUT
x 125%RESULT
200 38.00 238.00
240.00 A > / =238.00
(E) 200A MAIN
SERVICE PANEL
(E) GROUNDING
ELECTRODE
CIRCUIT A - 6
CIRCUIT B - 6
(N) 20A
(N)
SUNPOWER
PVS6
MONITORING
(3) #12 AWG
THWN-2
(L1, L2)
(1) #12 GND
3/4" EMT
CONDUIT
(N) 15A
AC MODULE SPECIFICATION
MANUFACTURER SUNPOWER
MODEL NO.SPR-M425-H-AC
NOMINAL POWER 425W
POWER TOLERANCE +5/-0%
AVERAGE PANEL EFFICIENCY 22.00%
TEMP COEF. POWER -0.29%/C°
INVERTER SPECIFICATION
MANUFACTURER SUNPOWER
MODEL NO. SPR-M425-H-AC (240V) [Sl1]
PEAK OUTPUT FACTOR 384W
AC MAX CONT. OUTPUT
CURRENT (240)1.60
DC/AC CEC CONVERSION
EFFICIENCY 97.0%
MAX UNITS PER 20A CIRCUIT 10 (SINGLE PHASE)
(N) 30A NON
FUSED AC
DISCONNECT CIRCUIT C
7 - MODULES
(ON DETACHED GARAGE)
(N) JBOX
NEMA 3R
CIRCUIT C - 7
(2) SUNPOWER
AC CABLES
(#12 AWG PV WIRES)
#6 BARE
COPPER (G)
(2) #10 AWG
THWN-2
(1L1, 1L2)
(1) #8 GND
3/4" EMT
CONDUIT
G G6 FT
APART MIN
2 GROUND
RODS WITH #6
GROUNDING
G
(2) #10 AWG
THWN-2
(L1, L2)
(1) #8 GND
IN EXISTING
CONDUIT
(N) 20A
CIRCUITS A & B
12 - MODULES
(ON MAIN HOUSE)
2014 N Flower St
09/12/22
REQUIRED
SIGNAGE
E3
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
WARNING: PHOTOVOLTAIC
POWER SOURCE
NEC 690.31(G)(3)(4)
ALL ROOF CONDUIT
MAIN PANEL
PHOTOVOLTAIC AC DISCONNECT
RATED AC OUTPUT CURRENT 30.40 A
NORMAL OPERATING VOLTAGE 240 V
NEC 690.54
PV SYSTEM
DISCONNECT !
MICROINVERTER AND ACM SYSTEMS PV LABELING
CEC ARTICLES 690 AND 705 AND CA RESIDENTIAL CODE SECTION R324 REQUIRE THE FOLLOWING
LABELS OR MARKINGS BE INSTALLED AT THESE COMPONENTS OF THE PHOTOVOLTAIC SYSTEM:
COMBINER BOX/SUBPANEL
WARNING
NEC 705.12(B)(3-4) & NEC 690.59
! !
DUAL POWER SUPPLY
SOURCES: UTILITY GRID AND
PV SOLAR ELECTRIC SYSTEM
RAPID SHUTDOWN SWITCH
FOR SOLAR PV SYSTEM
NEC 690.56(C)(3)
WARNING
NEC 705.12(B)(2)(c)
! !
POWER SOURCE OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
PV SYSTEM
DISCONNECT!
WARNING
NEC 690.13(B)
! !
ELECTRIC SHOCK HAZARD
TERMINAL ON THE LINE AND
LOAD SIDES MAY BE ENGERGIZED
IN THE OPEN POSITION
PHOTOVOLTAIC AC DISCONNECT
RATED AC OUTPUT CURRENT 30.40 A
NORMAL OPERATING VOLTAGE 240 V
NEC 690.54
PHOTOVOLTAIC SYSTEM
COMBINER PANEL
DO NOT ADD LOADS
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
TURN RAPID
SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUTDOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR ELECTRIC
PV PANELS
IF THERE IS NO INVERTER PLACE LABEL ON
COMBINER BOX, IF THERE IS NO COMBINER BOX
PLACE ON MAIN SERVICE PANEL.
DIRECTORY PLACARD
NEC 690.56(C)(1)
· ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES,
JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. (CFC 605.11.1, CEC
690.31[E], 690.17 & 690.53 & CRC R324)
·THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET,
WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL
PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. (CFC 605.1 1.1.4, CEC
690.31[E])
·MARKING IS PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY
VISIBLE FROM WHERE THE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRC R324)
·THE MARKINGS SAY WARNING: PHOTOVOLTAIC POWER SOURCE
AND HAVE 3/8-INCH (9.5 MM) MINIMUM-SIZED WHITE LETTERS ON A RED BACKGROUND. THE
SIGNS ARE MADE OF REFLECTIVE WEATHER RESISTANT MATERIAL. (CFC 605.11.1.1, 605.11.1.2)
·WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING
MATERIALS IN ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE
LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. (CEC 690.4)
·REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT.
NEC 705.10 & NEC 690.56(B) REQUIRES A PERMANENT PLAQUE OR DIRECTORY
DENOTING ALL ELECTRIC POWER SOURCE ON OR IN THE PREMISES OR RAPID FIRE
SHUTDOWN EQUIPMENT; INSTALL AT MAIN SERVICE PANEL
CAUTION
POWER TO THIS BUILDING ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN
I
J
DIRECTORY PLACARD
SOLAR
ARRAYS
MAIN SERVICE
PANEL
6"
6"
SIGNAGE NOTES
C
G
H
I
J
K
F
E
D
C
B
A
K
NO
R
T
H
F
L
O
W
E
R
S
T
R
E
E
T
PV SUBPANEL
DRIVEWAY
A M
AC COMBINER/
SUBPANEL
MAIN SERVICE
PANEL PV ARRAY
JBOX
A
C G H
I J B C D
E F KA
PV ARRAY
JBOX
A
AC
DISCONNECT
C G
AC DISCONNECT
2014 N Flower St
09/12/22
AC MODULE
DATA SHEET
E4
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
2014 N Flower St
09/12/22
MOUNTING
DATA SHEET
S1
OWNER
PROJECT TITLE
JOBSITE ADDRESS
SHEET TITLE
SHEET NUMBER
CONTRACTOR
15013 CALIFA STREET,
VAN NUYS, CA 91411
818-670-7769
WWW.PLUGITINSOLAR.COM
C-10 License # 986882
CHAD
BARKER
8.075 DC kW
AC MODULE
SYSTEM
7.296 kW CEC-AC RATING
2014
NORTH FLOWER ST
SANTA ANA
CA 92706
DESIGN BY: NT
NATALIA@PLUGITINSOLAR.COM
DATE
DRAWN
DESIGN
REVISION
DATE DESCRIPTION
REVISION
SIGNATURE OF LICENSE HOLDER
4-2-22
2014 N Flower St
09/12/22
Structural Calculations for a Roof Mounted Solar Photovoltaic System for:
Chad Barker
2014 N Flower St.,
Santa Ana, CA 92706
Applicable Codes:
2019 California Building Code, 2019 California Electric Code,
2019 California Mechanical Code, American Society of Civil Engineers
Standard ASCE 7-16 Minimum Design Loads for Buildings and Other
Structures, American Wood Council 2018 National Design Specification
for Wood Construction, Local Municipal Code, and all other codes which
are adopted by reference or enacted by law.
Assumed Design Parameters:
The existing structure has been built under a building permit and is in its
original condition. The existing roof structure is capable of its code
required live load and the ability of the roof structure to support live loads
has not been substantially reduced by the age of the structure, termites or
mold, or unauthorized modifications to the existing structure. Solar Energy
Contractor shall make inspection of the existing roof framing system prior
to installation of the roof mounted solar energy system to verify that the
existing roof is capable of supporting minimum roof live loads.
Assumed Design Parameters:
All 2x members are grade Douglas Fir #2 or better
All 4x members are grade Douglas Fir #1 or better
All Roof Connectors are Simpsons Strong-Tie or Equal
All Concrete Foundations are f'c = 2500 psi or stronger
Original Structure was built to the Type-V Wood Framed Standards
of the Applicable Building Code at the time of Construction.
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
2022-3209 Plug It In Solar Chad Barker
Sht # 1 of 8
Date: August 09, 2022
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2014 N Flower St
09/12/22
w DL + LL
R1 R2
w = 30 psf x 2 ft. = 60 plf
6'
(Assume max rafter span = 6.9 ft.)
= 60 plf x 6 ft. = 360 lbs
Note to Building Official:
Based upon a review of the proposed plans I am confident that the
existing roof framing system is capable of safely supporting the additional
loads caused by the solar photovoltaic energy system. The contractor
shall field verify that the existing roof structure is in its original permitted
condition and verify that it can support the normal code required roof live
loads. Attached in this package are several calculations showing that the
roof members can support the additional weight of the solar array.
Furthermore, an analysis of the solar array's support for wind forces and a
seismic analysis of the existing structure are also included.
Check 2x4 Rafters @ 24" O.C.*:
Total load on rafter
*Note: Contractor to Field Verify Framing
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224- 406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Sht # 2 of 8
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022
2014 N Flower St
09/12/22
w DL + LL = 30 psf x 2 ft. = 60 plf
= 28 plf x 6 ft. + ( 6' x 2.75' x 3 psf x 2 ) + ( 6' x 1.65' x 3 psf x 1 )
= 297 lbs < 360 lbs OK
Check attachment of Support to Existing Structure for Wind Uplift
CHECK SOLAR STRUCTURE ATTACHMENTS PER ASCE 7-16 WIND LOADS ON BUILDING
APPURTENANCES AND OTHER STRUCTURES Section 29.4.4 THEREFORE CHECK
ATTACHMENT FOR TYPICAL CRITICAL LOAD WHICH IS THE EDGE ZONE - ZONE 2.
NOTE: PER DEFINITION ON SHEETS 246 & 247 OF ASCE 7-16 EFFECTIVE WIND AREA:
"FOR ROOFTOP SOLAR ARRAYS, THE EFFECTIVE WIND AREA IN FIG. 29.4-7 IS
EQUAL TO THE TRIBUTARY AREA FOR THE STRUCTURAL ELEMENT BEING
CONSIDERED, EXCEPT THAT THE WIDTH OF THE EFFECTIVE WIND AREA NEED NOT
BE LESS THAN ONE-THIRD ITS LENGTH."
EFFECTIVE AREA = 15 SQ FT
w DL + LLreduced = 22 psf x 2 ft. = 44 plf
Check 2x4 Rafters @ 24" O.C.:
Total load on rafter
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224- 406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Sht # 3 of 8
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
R1 R2
6'
P P
w DL
P
2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022
2014 N Flower St
09/12/22
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Sht # 4 of 8
p =qh ðGCp ÞðγEÞðγa Þ
Kz = 0.9 (Exposure C, Height = 20 ft or less)
Kz = velocity pressure coefficient,
q h =0.00256KzKztKdKe V 2
Check attachment of Support to Existing Structure for Wind Uplift - Cont'd
Tributary Area to Each Solar Mount = 6 ft. x 2.75 ft. = 16.5 sq. ft. ( Max )
Calculate Design Wind Pressure at each support (Wind Speed 130 mph Exposure C):
Eq'n 29.4- 7 ASCE 7- 16
Section 26.10.1 ASCE 7- 16
Kzt = Topographical Factor = 1.0
Ke = Ground Elevation Factor = 1.0
V = 130 mph ; VASD = 101 mph Table 1609.3.1 2019 CBC
qh =0.00256 (0.9) (1.0) (0.85) (1.0) (101)2
qh =20 psf
p 20 psf (- 2.0) (1.5) (0.7) = - 42 psf
= - 2.0 (Zone 2 ; Effective Area = 15 sq. ft. )
= Exposure Factor = 1.5
GCp = Solar Array Pressure Equalization Factor = 0.7 Fig. 29.4- 8 ASCE 7- 16
Design (Factored) Uplift at each support = 0.6 x 693 lbs = 416 lbs
Nominal (Unfactored) Uplift at each support = 42 psf x 16.5 sq. ft. = 693 lbs
Note: Section 2.4.1 of ASCE 7- 16, Basic Load Combinations for Allowable Stress
Load per lag screw = 416 lbs / 1 = 416 lbs
Design. Note: Applicable Load Combination #5 (D + 0.6W)
p =qh ðGCp ÞðγEÞðγa Þ
Eq'n 26.10- 1 ASCE 7- 16
Note:
Kd = Wind Directionality Factor = 0.85
GCp )
γE
γa
=
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022
2014 N Flower St
09/12/22
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Check attachment of Support to Existing Structure for Wind Uplift - Cont'd
Use Support connected to 2x Min. Roof Member
w/ (1) 5/16" x 3.5" lag screw per connection minimum.
Determine allowable load per 5/16" lag screw w/ 2.5" embedment into wood below
according to the 2018 NDS.
W ' = W x Cd x Ct Table 10.3.1 2018 NDS
where:
W = 266 lbs / in. of embedment per Table 12.2A
Cd = 1.6 per Table 2.3.2 of 2018 NDS
Ct = 1.0 per Table 10.3.4 of 2018 NDS
W ' = 266 lbs/ in. x 2.5 in. x 1.6 x 1.0 = 1,064 lbs > 416 lbs OK
Sht # 5 of 8
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022
2014 N Flower St
09/12/22
Check Seismic load due to added dead load of photovoltaic system.
Determine Seismic Weight of Existing Building:
Effective Existing Seismic Weight (main house)
Area of (E) Building = Approximately 1,700 sq. ft.
Approximate
Effective
Seismic Weight
= 1,700 sq. ft. x 30 psf ave. = 51,000 LBS
DETERMINE BASE SHEAR
V = Cs W EQ'N 12.8-1 ASCE 7-16
Cs =
SDS
R
l e
EQ'N 12.8-2 ASCE 7-16
R = THE RESPONSE MODIFICATION FACTOR IN TABLE 12.2-1
R = 6.5 WOOD SHEAR WALLS
e l = 1.0 IMPORTANCE FACTOR
SDS = 2/3 x S MS EQ'N 11.4-3 ASCE 7-16
SMS = FA x SS EQ'N 11.4-1 ASCE 7-16
SMS = 1.2 x 1.5 = 1.8
SDS = 2/3 x 1.8 = 1.2
Cs =
1.2
6.5
1
= 0.185 EQ'N 12.8-2 ASCE 7-16
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224- 406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Sht # 6 of 8
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022
2014 N Flower St
09/12/22
EXISTING BASE SHEAR
V = 0.185 x 51,000 LBS = 9,435 LBS EQ'N 12.8-1 ASCE 7-10
DETERMINE NEW BASE SHEAR
Determine Seismic Weight of Building with Solar Array:
EXISTING
SEISMIC
WEIGHT
= 51,000 LBS
NEW SOLAR
ARRAY 3 PSF x 12 PANELS x 3.3' x 5.5' = 653 LBS=
NEW
SEISMIC
WEIGHT
= 51,000 LBS + 653 LBS = 51,653 LBS
THEREFORE NEW BASE SHEAR:
V = 0.185 x 51,653 = 9,556 LBS EQ'N 12.8-1 ASCE 7-10
% CHANGE =9,556 LBS - 9,435 LBS
9,435 LBS x 100 = 1.3 % < 10% OK
Effective Existing Seismic Weight (garage)
Area of (E) Building = Approximately 600 sq. ft.
Approximate
Effective
Seismic Weight
= 600 sq. ft. x 20 psf ave. = 12,000 LBS
Sht # 7 of 8
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022
2014 N Flower St
09/12/22
V = 0.185 x 12,000 LBS = 2,220 LBS EQ'N 12.8-1 ASCE 7-16
DETERMINE NEW BASE SHEAR
Determine Seismic Weight of Building with Solar Array:
EXISTING
SEISMIC
WEIGHT
= 12,000 LBS
NEW SOLAR
ARRAY 3 PSF x 7 PANELS x 3.3' x 5.5' = 381 LBS=
NEW
SEISMIC
WEIGHT
= 12,000 LBS + 381 LBS = 12,381 LBS
THEREFORE NEW BASE SHEAR:
V = 0.185 x 12,381 = 2,291 LBS EQ'N 12.8-1 ASCE 7-16
% CHANGE = 2,291 LBS - 2,220 LBS
2,220 LBS x 100 = 3.2 % < 10% OK
OK. PER ASCE 7-16 SECTION 11.B.3 ALTERATIONS
EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT
FROM ANALYSIS SINCE NEW SEISMIC FORCE IS
LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE.
"Alterations are permitted to be made to any structure without requiring the
existing structure to comply with this standard provided the alterations comply
with the requirements for a new structure. Alterations that increase the
seismic force in any existing structural element by more than 10 percent or
decrease the design strength of any existing structural element to resist
seismic forces by more than 10 percent shall not be permitted unless the
entire seismic force-resisting system is determined to comply with this
standard for a new structure."
End of Calculations
EXISTING BASE SHEAR
Loyd W. Martin Professional Engineer, Inc.
9924 Universal Boulevard #224- 406 Orlando, FL 32819 Tel:1.310.464.1804
Email: loydwmartin@gmail.com www.loydwmartin.com
Sht # 8 of 8
Exp. 3-31-19
No. C58724
NITRAMW.DYO
REGISTEREDPROFESSIONALENGINEER
C
V
L
FOETATS
ALIFORNIAICIL
123
2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022
2014 N Flower St
09/12/22
Expedited Permit Process for PV Systems - AC Module1
Expedited Permit Process for PV Systems
AC Module
The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro-
cess provides a means to differentiate systems that can be permitted quickly and easily
due to their similarity with the majority of small-scale PV systems. Those systems with
unique characteristics may be handled with small additions to this Expedited Permit
Process or may require much more information, depending on the uniqueness of the
installation.
The following pages contain forms for the AC Module to use with the Expedited Permit
Process. The Standard String, Micro-Inverter, and Supply-Side Connection forms
are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic-
tions that have adopted the Expedited Permit Process for PV Systems, these forms can
be filled out electronically and submitted in either printed form and via email. An elec-
tronic format is used so that the supplied information is standardized and legible for the
local jurisdiction.
2014 N Flower St
09/12/22
Expedited Permit Process for PV Systems2
Expedited Permit Process for Small-Scale PV Systems
AC Module
The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations
are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential
systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been
suggested to provide as a path to permit approval.
Required Information for Permit:
1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it
should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings
with a 3’ perimeter space at ridge and sides may not need separate fire service review.
2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects,
required signs, and ac connection to building (see supplied standard electrical diagram).
3. Specification sheets and installation manuals (if available) for all manufactured components including, but not
limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system.
Step 1: Structural Review of PV Array Mounting System
Is the array to be mounted on a defined, permitted roof structure? l Yes l No
If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1.
Roof Information:
1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________
____________________________________________________________________________________________________
If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…).
2. Does the roof have a single roof covering? l Yes l No
If No, submit completed worksheet for roof structure WKS1.
3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________
Mounting System Information:
1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap
beneath the module frames? l Yes l No
If No, provide details of structural attachment certified by a design professional.
2. For manufactured mounting systems, fill out information on the mounting system below:
a. Mounting System Manufacturer ___________Product Name and Model#________________________________
b. Total Weight of PV Modules and Rails ___________lbs
c. Total Number of Attachment Points____________
d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1)
e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for
maximum spacing allowed based on maximum design wind speed)
f. Total Surface Area of PV Modules (square feet)_________________ ft 2
g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2
If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1.
Step 2: Electrical Review of PV System (Calculations for Electrical Diagram)
In order for a PV system to be considered for an expedited permit process, the following must apply:
1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems.
2. The PV array is composed of 4 series strings or less per inverter.
3. The total inverter capacity has a continuous ac power output 13,440 Watts or less
4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)).
5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV
system. Interactive PDF diagrams are available at www.solarabcs.org/permitting.
Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant
understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively
communicate, provide an alternative diagram with appropriate detail.
2014 N Flower St
09/12/22
Ex
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
3
AC Module Site Plan
2014 N Flower St
09/12/22
Ex
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
4
AC Module Electrical Diagram
Contractor Name,
Address and Phone:
One-Line Standard Electrical Diagram
for AC Module PV Systems
Site Name:
Site Address:
System AC Size:
SIZE FSCM NO DWG NO REV
SCALE NTS Date: SHEET
Drawn By:
Checked By:
DESCRIPTION OR CONDUCTOR TYPE
USE-2 or PV WIRE
GEC EGC X ALL THAT APPLY
EXTERIOR CABLE LISTED W/ INV.
THWN-2 or XHHW-2 or RHW-2
GEC EGC X ALL THAT APPLY
NO DC GEC IF 690.35 SYSTEM
THWN-2 or XHHW-2 or RHW-2
GEC EGC X ALL THAT APPLY
TAG
1
2
3
4
5
CONDUIT AND CONDUCTOR SCHEDULE
COND.
GAUGE
MFG
MFG
NUMBER OF
CONDUCTORS
MFG Cable
MFG Cable
CONDUIT
TYPE
N/A
N/A
N/A
CONDUIT
SIZE
N/A
N/A
N/A
DESCRIPTIONTAG
1
2
3
4
5
6
7
PART NUMBER NOTES
FOR UNUSED AC MODULES
PUT "N/A in BLANK ABOVE
1
2
2
3
EQUIPMENT SCHEDULE
J-BOX
4
AC DISCO
M
BUILDING
GROUNDING
ELECTRODE
G
M
UTILITY
SERVICE
MAIN SERVICE PANEL
MAIN
OCPD
INVERTER
OCPD
5
6
7
5
3
4
G
SEE GUIDE APPENDIX D FOR
INFORMATION ON MODULE AND
ARRAY GROUNDING
AC COMBINER
PANEL
G
____
AC MODULES
IN BRANCH-
CIRCUIT
MOD
__1__
DC
AC
MOD
__1__
DC
AC
MOD
__1__
DC
AC
____
AC MODULES
IN BRANCH-
CIRCUIT
MOD
__1__
DC
AC
MOD
__1__
DC
AC
MOD
__1__
DC
AC
1
2014 N Flower St
09/12/22
Ex
p
e
d
i
t
e
d
P
e
r
m
i
t
P
r
o
c
e
s
s
f
o
r
P
V
S
y
s
t
e
m
s
5
Notes for AC Module Electrical Diagram
Contractor Name,
Address and Phone:
Bill
Ted
Notes for One-Line Standard Electrical
Diagram for Single-Phase PV Systems
Site Name:
Site Address:
System AC Size:
SIZE FSCM NO DWG NO REV
SCALE NTS Date: SHEET
Drawn By:
Checked By:
NOMINAL OPERATING AC VOLTAGE
NOMINAL OPERATING AC FREQUENCY
MAXIMUM AC POWER
MAXIMUM AC CURRENT
MAXIMUM OCPD RATING
AC MODULE MAKE
AC MODULE MODEL
AC MODULE RATINGS (Guide Appendix C)
1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE
REQUIREMENT? YES NO N/A
2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE
REQUIREMENT? YES NO N/A
3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX
CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT (N/A)
4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER
OCPD AMPERE RATING. (See Guide Section 9)
5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH AC
MODULE CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR
EXCEPTION IN 690.64(B)(2)(a)? YES NO
NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9):
1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN
EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC
2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST
MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ___oC
2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED
47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR 6 OR LESS
CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT
LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF
47oC OR LESS (ALL OF UNITED STATES),
a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR AC MODULES
INVERTER OUTPUT CIRCUITS WITH 12 AMPS OR LESS WHEN PROTECTED BY A 15-
AMP OR SMALLER OCPD.
b) 10 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR AC MODULES
INVERTER OUTPUT CIRCUITS WITH 16 AMPS OR LESS WHEN PROTECTED BY A 20-
AMP OR SMALLER OCPD.
NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix F):
OCPD = OVERCURRENT PROTECTION DEVICE
NATIONAL ELECTRICAL CODE®REFERENCES
SHOWN AS (NEC XXX.XX)
NOTES FOR ALL DRAWINGS:
SIGNSSEE GUIDE SECTION 7
SIGN FOR DC DISCONNECT
SIGN FOR INVERTER OCPD AND AC
DISCONNECT (IF USED)
N/A since no dc wiring
AC OUTPUT CURRENT
NOMINAL AC VOLTAGE
SOLAR PV SYSTEM
AC POINT OF CONNECTION
THIS PANEL FED BY MULTIPLE
SOURCES (UTILITY AND SOLAR)
2014 N Flower St
09/12/22
Rev: 7/15/2021
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
SOL-01 CBC 2019
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1. Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2. Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3. Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4. Will the PV system weigh maximum 4 pounds per square feet or less?
5. Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6. Will the PV system be installed with a space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
7. Will the PV system be installed without using any ballast system or counter-weight
system?
8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
Luis Ocampo Digitally signed by Luis Ocampo
DN: cn=Luis Ocampo, o, ou,
email=Luis.Ocampo@plugitinsolar.com, c=US
Date: 2022.08.02 13:57:38 -07'00'
2014 N Flower St
09/12/22