HomeMy WebLinkAbout2014 N Flower St - Plan PROJECT SITE OWNER:CHAD BARKER ADDRESS:2014 NORTH FLOWER ST SANTA ANA, CA 92706 APN:39905105 UTILITY:SCE AHJ:ORANGE COUNTY CONSTRUCTION TYPE: VB OCCUPANCY TYPE: R3 ELEVATION: 138 FT ABOVE SEA LEVEL PROJECT INFO VICINITY MAP A0 SOLAR PHOTOVOLTAIC SYSTEM NOTES 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS, CEC 110.2, 110.3, 690.4(B) AND 690.12(D). 2. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 3. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 4. ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT PER CEC 690.9. 5. DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY ACCESSIBLE LOCATION NEAR THE EQUIPMENT, CEC 690.13, 690.15. 6. ENERGY STORAGE SYSTEMS TERMINALS LOCATED MORE THAN 5 FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM CONNECTED EQUIPMENT MUST HAVE DISCONNECTING MEANS IN ACCORDANCE WITH CEC 706.7(E) AND LABELED PER 706.7(D). A SECOND DISCONNECTING MEANS LOCATED AT THE CONNECTED EQUIPMENT SHALL BE INSTALLED WHERE THE DISCONNECTING MEANS AT THE ESS END OF THE CIRCUIT IS NOT WITHIN SIGHT. 7. RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12. 8. THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, CEC 705.40. 9. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR THE APPLICATION. CEC310.10(D) AND 690.31(C) THROUGH (F). 10. INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS, CEC 690.31(C). 11. FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC 110.14. 12. ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION, CEC 690.31(B). 13. ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC 200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C). 14. MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, CEC 705.31. 15. CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, CEC 705.12(B). 16. DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS, CEC 690.31(G). 17. METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED IN ACCORDANCE WITH CEC 250.97. 18. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS, CEC 314.15 19. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IDENTIFIED AND LISTED FOR SUCH USE, CEC 690.31(H) & 110.14. 20. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING”, CEC 690.33(C) & (E)(2). 21. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C). 22. THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, CEC 705.32. 23. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED, CEC 300.4. 24. PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY COMPANY. 25. FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDE, CEC 250.104. 26. GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH SOIL, CEC 250.52(A)(5), 250.53(G). 27. MINIMUM 7/8’’ CLEARANCE FROM ROOF TO BOTTOM OF CONDUIT OR USE A TEMPERATURE ADDER OF 33 DEGREES C. CEC 310.15(B)(3)(C) 28. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 29. EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE PROPOSED MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE MODULES, CPC 906.1. 30. EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1). 31. THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10' O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, CEC 690.31(G)(4). 32. PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS ONLY NO LOADS ARE TO BE CONNECTED. 33. WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, CEC 110.26. 34. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND EXTENDING 3' ABOVE THE ROOF. 35. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. 36. LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN WHITE ON A RED BACKGROUND. CEC 690.31(G)(4) 37. IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). 38. WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT. 39. PANELS AND MODULES NOT TO BE INSTALLED ON ROOF BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. CRC R324.6.2.2 40. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF 5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES, CRC R324.7 & R302.1. 41. PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY. 42. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. 43. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. R314.1, R315.1 44. ROOF ACCESS POINTS. ROOF ACCESS POINTS SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS (R331.4.1).LADDERS SHALL BE OSHA APPROVED AND SECURED TO THE STRUCTURE FOR INSPECTION PURPOSES.CONTRACTORS ARE REQUIRED TO BE PRESENT FOR THE FIRST AND/OR FINAL INSPECTIONS. 45. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 8.075 DC KW SOLAR PV AC MODULE SYSTEM- ROOF MOUNT BARKER RESIDENCE 2014 NORTH FLOWER ST, SANTA ANA, CA 92706 APPLICABLE CODES ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES 2019 CA BUILDING CODES (CBC) 2019 CA RESIDENTIAL CODES (CRC) 2019 CA MECHANICAL CODES (CMC) 2019 CA PLUMBING CODES (CPC) 2019 CA FIRE CODES (CFC) 2019 CA ELECTRICAL CODES (CEC) 2019 CA ENERGY CODES (CEnC) 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen) PROJECT SITE VICINITY MAP AERIAL VIEW OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 PROJECT SCOPE INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM NEW EQUIPMENT:19 SPR-M425-H-AC SUNPOWER AC MODULES 19 SPR-M425-H-AC (240V) [Sl1] SUNPOWER INVERTERS SYSTEM SIZE: 8.075 DC kW RATING 7.296 CEC AC RATING SERVICE: EXISTING 200A MAIN SERVICE PANEL ARRAY AREA: 20.78 SQFT X 19 = 394.82 SQFT SHEET INDEX A0 PROJECT INFO, VICINITY MAP, NOTES A1 SITE PLAN A2 MOUNTING PLAN A3 MOUNTING DETAILS E1 SINGLE LINE DIAGRAM E2 ELECTRICAL CALCULATIONS E3 REQUIRED SIGNAGE E4 AC MODULE DATA SHEET S1 MOUNTING DATA SHEET S2 RACKING DATA SHEET S3 RACKING GROUNDING S4 RACKING CERTIFICATION www. Loyd W Martin .com Solar Structures Engineering #2022-3209 Structural Only August 09, 2022 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 ***HISTORIC PROPERTY*** Bldg #101111890 Elect #20177292 Permits issued on 9/12/22 Plng ok per P. Gomez 2014 N Flower St 09/12/22 RACKING DATA SHEET S2 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 2014 N Flower St 09/12/22 GROUNDING METHOD S3 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 2014 N Flower St 09/12/22 RACKING CERTIFICATION S4 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 2014 N Flower St 09/12/22 SITE PLAN A1 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 NOTE: FOR FIRE SETBACKS, FIRE ACCESS POINTS, CONDUIT ROUTES AND LOCATION OF THE JUNCTION BOXES AND RACKING INFORMATION, PLEASE REFER TO PAGE A-2 MOUNTING PLAN PROPERTY LINE SITE PLAN SCALE: 1/16" = 1' LEGEND: (E) - EXISTING (N) - NEW NO R T H F L O W E R S T R E E T (E) DRIVEWAY (E) POOL (E) 200A MAIN SERVICE PANEL (N) 125A PV SUBPANEL (N) 19 - SPR-M425-E-AC SUNPOWER AC MODULES (N) 19 - SPR-M425-E-AC(240V) [SI1] SUNPOWER INVERTERS (N) 30A AC DISCONNECT www. Loyd W Martin .com Solar Structures Engineering #2022-3209 Structural Only August 09, 2022 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2014 N Flower St 09/12/22 C C C C C C C A A A A A B B B B B B A MOUNTING PLAN A2 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 MOUNTING PLAN SCALE: 1" = 10' LEGEND: (E) - EXISTING (N) - NEW - CONDUIT RUN - JUNCTION BOX - MAIN SERVICE PANEL - SUBPANEL JB MSP SP CIRCUIT A - 6 MODULES/MICROS CIRCUIT B - 6 MODULES/MICROS CIRCUIT C - 7 MODULES/MICROS FIRE ACCESS POINT AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS FIRE ACCESS POINT AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS (N) 19 - SPR-M425-E-AC SUNPOWER AC MODULES (N) 19 - SPR-M425-E-AC(240V) [SI1] SUNPOWER INVERTERS 3' 3' 3' PATHWAY PER R324.6.1 3' PATHWAY PER R324.6.1 3' FIRE SETBACK 3' FIRE SETBACK 18" FI R E S E T B A C K MSP SP D (N) 30A AC DISCONNECT EXISTING CONDUIT (N) 125A PV SUBPANEL (E) 200A MAIN SERVICE PANEL JB JB 3/4" EMT CONDUIT RUN ABOVE ROOF OR UNDER EAVES WHERE POSSIBLE WIRING / CONDUIT RACEWAY WILL BE 7/8'' MINIMUM ABOVE THE ROOFTOP PER CEC 310.15(B)(3)(c) INVISIMOUNT ROW-TO-ROW GROUNDING CLIPS 32 TOTAL ATTACHMENTS @ 6FT OC MAX 270° AZIMUTH 24° SLOPE 180° AZIMUTH 24° SLOPE 270° AZIMUTH 24° SLOPE G G 6 FT APART MIN 2 GROUND RODS WITH #6 GROUNDING www. Loyd W Martin .com Solar Structures Engineering #2022-3209 Structural Only August 09, 2022 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2014 N Flower St 09/12/22 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 ROOF INFO ROOFING: COMP SHINGLE - 1 LAYER YEAR BUILT: 1941 ROOF PITCH: 24° ROOF FRAME MEMBERS: 2 X 4 RAFTERS ON CENTER SPACING: 24" RAFTER SPAN: 6' MAX ATTACHMENT SPACING O.C: 72" MODULES COVER 18.1 % OF THE ROOF AREA LESS THAN 33% (CRC 324.6.2) ROOF ATTACHMENT DETAIL SCALE: NOT TO SCALE NOTE: MODULES WILL BE INSTALLED FLUSHED TO EXISTING ROOF SLOPE SOLAR PANEL DEAD WEIGHT CALCULATION RACKING MANUFACTURER INVISIMOUNT RACKING MODULE SUNPOWER SPR-M425-H-AC TOTAL # OF MODULES 19 MOUNTING SYSTEM WEIGHT 72.00 LBS MODULE WEIGHT 48.0 LBS TOTAL MODULES WEIGHT 912.00 LBS MODULES LENGTH 73.7 INCHES TOTAL SYSTEM WEIGHT 984.00 LBS MODULES WIDTH 40.6 INCHES POINT LOAD CALCULATION 30.75 LBS MODULES AREA 20.78 SQFT TOTAL SOLAR MODULE AREA 394.81 SQFT TOTAL # OF ATTACHMENTS 32 DISTRIBUTED LOAD CALCULATION THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 2.49 PSF RACKING WEIGHT 0.56 LBS/LN FT ROOF COVERAGE TOTAL MODULE AREA 394.81 R324.6.2 SET BACK AT RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING NOT MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN AN 18-INCH (457 MM) CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, NOT LESS THAN A 36-INCH (914 MM) CLEAR SET BACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. ROOF FACE AREA 2184 ROOF COVERAGE (%)18.1 18.1% < / = 33% = OK MOUNTING DETAILS A3 NOTE: Engineer of Record assumes that all structural components of the existing building were permitted and met the requirements of the Building Code at the time of construction. Solar Contractor shall field verify that the roof framing is in its existing permitted condition and capable of supporting required live loads. Framing specified on solar plans shall be assumed to be minimum size and spacing, actual framing may be different. www. Loyd W Martin .com Solar Structures Engineering #2022-3209 Structural Only August 09, 2022 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2014 N Flower St 09/12/22 SINGLE LINE DIAGRAM E1 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 705.12(B)(2)(3) BUSBARS (B) WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. THE BUSBAR SHALL BE SIZED FOR THE LOADS CONNECTED IN ACCORDANCE WITH ARTICLE 220. A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE POWER SOURCE THAT DISPLAYS THE FOLLOWING OR EQUIVALENT WORDING: WARNING: POWER SOURCE OUTPUT CONNECTION ? DO NOT RELOCATE THIS OVERCURRENT DEVICE. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 110.21(B). NOTE: TERMINATE LUGS AT 75° BRANCH CIRCUIT CALCULATION CIRCUIT MAX AC OUTPUT (AMPS) # OF MODULES RESULT (AMPS)125%RESULT (AMPS) OCPD SIZE A 1.60 6 9.60 1.25 12.00 20 B 1.60 6 9.60 1.25 12.00 20 C 1.60 7 11.20 1.25 14.00 20 NOTE: THE ENPHASE IQ MICROINVERTER SYSTEM USES A NEW AND IMPROVED CABLING SYSTEM. THE Q CABLE IS DG TYPE AND CONTAINS ONLY TWO #12 AWG LINE CONDUCTORS. THE Q CABLE MALE CONNECTORS PLUG DIRECTLY INTO THE IQ MICROS, WHOSE DOUBLE INSULATION RATING REQUIRES NO NEUTRAL OR GROUND CONDUCTORS (N) JBOX NEMA 3R (4) #10 AWG THWN-2 (2L1, 2L2) (1) #8 GND 3/4" EMT CONDUIT (4) SUNPOWER AC CABLES (#12 AWG PV WIRES) #6 BARE COPPER (G)M PV BREAKER MUST BE INSTALLED AT THE FARTHEST OPPOSITE END OF THE MAIN BREAKER G N SOLAR GROUND TYING INTO EXISTING UFER GROUND POINT (N) 125A PV SUBPANEL COMBINER *NO ADDITIONAL LOADS* (N) 20A (E) 200A MSB (N) 40A PV OCPD (3) #8 AWG THWN-2 (L1, L2, N) (1) #8 GND 1" EMT CONDUIT G N 240V, 1PHASE, 3W TOP FED (N) 19 - SPR-M425-E-AC SUNPOWER AC MODULES (N) 19 - SPR-M425-E-AC(240V) [SI1] SUNPOWER INVERTERS SUM OF CIRCUITS WITH 125% MAX AC OUTPUT (AMPS TOTAL # OF MICROS TOTAL MAX AC OUTPUT 125%RESULT (AMPS) OCPD SIZE 1.60 19 30.40 1.25 38.00 40A SERVICE LOAD CALCULATIONS BACKFED 120% RULE - PER 705.12(B)(2)(3)(B) BUS RATING SIZE MULTIPLIER(120%)RESULT 200 1.20 240.00 MAIN BREAKER INVERTER AC OUTPUT x 125%RESULT 200 38.00 238.00 240.00 A > / =238.00 (E) 200A MAIN SERVICE PANEL (E) GROUNDING ELECTRODE CIRCUIT A - 6 CIRCUIT B - 6 (N) 20A (N) SUNPOWER PVS6 MONITORING (3) #12 AWG THWN-2 (L1, L2) (1) #12 GND 3/4" EMT CONDUIT (N) 15A AC MODULE SPECIFICATION MANUFACTURER SUNPOWER MODEL NO.SPR-M425-H-AC NOMINAL POWER 425W POWER TOLERANCE +5/-0% AVERAGE PANEL EFFICIENCY 22.00% TEMP COEF. POWER -0.29%/C° INVERTER SPECIFICATION MANUFACTURER SUNPOWER MODEL NO. SPR-M425-H-AC (240V) [Sl1] PEAK OUTPUT FACTOR 384W AC MAX CONT. OUTPUT CURRENT (240)1.60 DC/AC CEC CONVERSION EFFICIENCY 97.0% MAX UNITS PER 20A CIRCUIT 10 (SINGLE PHASE) (N) 30A NON FUSED AC DISCONNECT CIRCUIT C 7 - MODULES (ON DETACHED GARAGE) (N) JBOX NEMA 3R CIRCUIT C - 7 (2) SUNPOWER AC CABLES (#12 AWG PV WIRES) #6 BARE COPPER (G) (2) #10 AWG THWN-2 (1L1, 1L2) (1) #8 GND 3/4" EMT CONDUIT G G6 FT APART MIN 2 GROUND RODS WITH #6 GROUNDING G (2) #10 AWG THWN-2 (L1, L2) (1) #8 GND IN EXISTING CONDUIT (N) 20A CIRCUITS A & B 12 - MODULES (ON MAIN HOUSE) 2014 N Flower St 09/12/22 REQUIRED SIGNAGE E3 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 WARNING: PHOTOVOLTAIC POWER SOURCE NEC 690.31(G)(3)(4) ALL ROOF CONDUIT MAIN PANEL PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 30.40 A NORMAL OPERATING VOLTAGE 240 V NEC 690.54 PV SYSTEM DISCONNECT ! MICROINVERTER AND ACM SYSTEMS PV LABELING CEC ARTICLES 690 AND 705 AND CA RESIDENTIAL CODE SECTION R324 REQUIRE THE FOLLOWING LABELS OR MARKINGS BE INSTALLED AT THESE COMPONENTS OF THE PHOTOVOLTAIC SYSTEM: COMBINER BOX/SUBPANEL WARNING NEC 705.12(B)(3-4) & NEC 690.59 ! ! DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM NEC 690.56(C)(3) WARNING NEC 705.12(B)(2)(c) ! ! POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE PV SYSTEM DISCONNECT! WARNING NEC 690.13(B) ! ! ELECTRIC SHOCK HAZARD TERMINAL ON THE LINE AND LOAD SIDES MAY BE ENGERGIZED IN THE OPEN POSITION PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT 30.40 A NORMAL OPERATING VOLTAGE 240 V NEC 690.54 PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS IF THERE IS NO INVERTER PLACE LABEL ON COMBINER BOX, IF THERE IS NO COMBINER BOX PLACE ON MAIN SERVICE PANEL. DIRECTORY PLACARD NEC 690.56(C)(1) · ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. (CFC 605.11.1, CEC 690.31[E], 690.17 & 690.53 & CRC R324) ·THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. (CFC 605.1 1.1.4, CEC 690.31[E]) ·MARKING IS PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERE THE DISCONNECT IS OPERATED. (CFC 605.11.1.3 & CRC R324) ·THE MARKINGS SAY WARNING: PHOTOVOLTAIC POWER SOURCE AND HAVE 3/8-INCH (9.5 MM) MINIMUM-SIZED WHITE LETTERS ON A RED BACKGROUND. THE SIGNS ARE MADE OF REFLECTIVE WEATHER RESISTANT MATERIAL. (CFC 605.11.1.1, 605.11.1.2) ·WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. (CEC 690.4) ·REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. NEC 705.10 & NEC 690.56(B) REQUIRES A PERMANENT PLAQUE OR DIRECTORY DENOTING ALL ELECTRIC POWER SOURCE ON OR IN THE PREMISES OR RAPID FIRE SHUTDOWN EQUIPMENT; INSTALL AT MAIN SERVICE PANEL CAUTION POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN I J DIRECTORY PLACARD SOLAR ARRAYS MAIN SERVICE PANEL 6" 6" SIGNAGE NOTES C G H I J K F E D C B A K NO R T H F L O W E R S T R E E T PV SUBPANEL DRIVEWAY A M AC COMBINER/ SUBPANEL MAIN SERVICE PANEL PV ARRAY JBOX A C G H I J B C D E F KA PV ARRAY JBOX A AC DISCONNECT C G AC DISCONNECT 2014 N Flower St 09/12/22 AC MODULE DATA SHEET E4 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 2014 N Flower St 09/12/22 MOUNTING DATA SHEET S1 OWNER PROJECT TITLE JOBSITE ADDRESS SHEET TITLE SHEET NUMBER CONTRACTOR 15013 CALIFA STREET, VAN NUYS, CA 91411 818-670-7769 WWW.PLUGITINSOLAR.COM C-10 License # 986882 CHAD BARKER 8.075 DC kW AC MODULE SYSTEM 7.296 kW CEC-AC RATING 2014 NORTH FLOWER ST SANTA ANA CA 92706 DESIGN BY: NT NATALIA@PLUGITINSOLAR.COM DATE DRAWN DESIGN REVISION DATE DESCRIPTION REVISION SIGNATURE OF LICENSE HOLDER 4-2-22 2014 N Flower St 09/12/22 Structural Calculations for a Roof Mounted Solar Photovoltaic System for: Chad Barker 2014 N Flower St., Santa Ana, CA 92706 Applicable Codes: 2019 California Building Code, 2019 California Electric Code, 2019 California Mechanical Code, American Society of Civil Engineers Standard ASCE 7-16 Minimum Design Loads for Buildings and Other Structures, American Wood Council 2018 National Design Specification for Wood Construction, Local Municipal Code, and all other codes which are adopted by reference or enacted by law. Assumed Design Parameters: The existing structure has been built under a building permit and is in its original condition. The existing roof structure is capable of its code required live load and the ability of the roof structure to support live loads has not been substantially reduced by the age of the structure, termites or mold, or unauthorized modifications to the existing structure. Solar Energy Contractor shall make inspection of the existing roof framing system prior to installation of the roof mounted solar energy system to verify that the existing roof is capable of supporting minimum roof live loads. Assumed Design Parameters: All 2x members are grade Douglas Fir #2 or better All 4x members are grade Douglas Fir #1 or better All Roof Connectors are Simpsons Strong-Tie or Equal All Concrete Foundations are f'c = 2500 psi or stronger Original Structure was built to the Type-V Wood Framed Standards of the Applicable Building Code at the time of Construction. Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com 2022-3209 Plug It In Solar Chad Barker Sht # 1 of 8 Date: August 09, 2022 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2014 N Flower St 09/12/22 w DL + LL R1 R2 w = 30 psf x 2 ft. = 60 plf 6' (Assume max rafter span = 6.9 ft.) = 60 plf x 6 ft. = 360 lbs Note to Building Official: Based upon a review of the proposed plans I am confident that the existing roof framing system is capable of safely supporting the additional loads caused by the solar photovoltaic energy system. The contractor shall field verify that the existing roof structure is in its original permitted condition and verify that it can support the normal code required roof live loads. Attached in this package are several calculations showing that the roof members can support the additional weight of the solar array. Furthermore, an analysis of the solar array's support for wind forces and a seismic analysis of the existing structure are also included. Check 2x4 Rafters @ 24" O.C.*: Total load on rafter *Note: Contractor to Field Verify Framing Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224- 406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Sht # 2 of 8 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022 2014 N Flower St 09/12/22 w DL + LL = 30 psf x 2 ft. = 60 plf = 28 plf x 6 ft. + ( 6' x 2.75' x 3 psf x 2 ) + ( 6' x 1.65' x 3 psf x 1 ) = 297 lbs < 360 lbs OK Check attachment of Support to Existing Structure for Wind Uplift CHECK SOLAR STRUCTURE ATTACHMENTS PER ASCE 7-16 WIND LOADS ON BUILDING APPURTENANCES AND OTHER STRUCTURES Section 29.4.4 THEREFORE CHECK ATTACHMENT FOR TYPICAL CRITICAL LOAD WHICH IS THE EDGE ZONE - ZONE 2. NOTE: PER DEFINITION ON SHEETS 246 & 247 OF ASCE 7-16 EFFECTIVE WIND AREA: "FOR ROOFTOP SOLAR ARRAYS, THE EFFECTIVE WIND AREA IN FIG. 29.4-7 IS EQUAL TO THE TRIBUTARY AREA FOR THE STRUCTURAL ELEMENT BEING CONSIDERED, EXCEPT THAT THE WIDTH OF THE EFFECTIVE WIND AREA NEED NOT BE LESS THAN ONE-THIRD ITS LENGTH." EFFECTIVE AREA = 15 SQ FT w DL + LLreduced = 22 psf x 2 ft. = 44 plf Check 2x4 Rafters @ 24" O.C.: Total load on rafter Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224- 406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Sht # 3 of 8 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 R1 R2 6' P P w DL P 2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022 2014 N Flower St 09/12/22 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Sht # 4 of 8 p =qh ðGCp ÞðγEÞðγa Þ Kz = 0.9 (Exposure C, Height = 20 ft or less) Kz = velocity pressure coefficient, q h =0.00256KzKztKdKe V 2 Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Tributary Area to Each Solar Mount = 6 ft. x 2.75 ft. = 16.5 sq. ft. ( Max ) Calculate Design Wind Pressure at each support (Wind Speed 130 mph Exposure C): Eq'n 29.4- 7 ASCE 7- 16 Section 26.10.1 ASCE 7- 16 Kzt = Topographical Factor = 1.0 Ke = Ground Elevation Factor = 1.0 V = 130 mph ; VASD = 101 mph Table 1609.3.1 2019 CBC qh =0.00256 (0.9) (1.0) (0.85) (1.0) (101)2 qh =20 psf p 20 psf (- 2.0) (1.5) (0.7) = - 42 psf = - 2.0 (Zone 2 ; Effective Area = 15 sq. ft. ) = Exposure Factor = 1.5 GCp = Solar Array Pressure Equalization Factor = 0.7 Fig. 29.4- 8 ASCE 7- 16 Design (Factored) Uplift at each support = 0.6 x 693 lbs = 416 lbs Nominal (Unfactored) Uplift at each support = 42 psf x 16.5 sq. ft. = 693 lbs Note: Section 2.4.1 of ASCE 7- 16, Basic Load Combinations for Allowable Stress Load per lag screw = 416 lbs / 1 = 416 lbs Design. Note: Applicable Load Combination #5 (D + 0.6W) p =qh ðGCp ÞðγEÞðγa Þ Eq'n 26.10- 1 ASCE 7- 16 Note: Kd = Wind Directionality Factor = 0.85 GCp ) γE γa = Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022 2014 N Flower St 09/12/22 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Check attachment of Support to Existing Structure for Wind Uplift - Cont'd Use Support connected to 2x Min. Roof Member w/ (1) 5/16" x 3.5" lag screw per connection minimum. Determine allowable load per 5/16" lag screw w/ 2.5" embedment into wood below according to the 2018 NDS. W ' = W x Cd x Ct Table 10.3.1 2018 NDS where: W = 266 lbs / in. of embedment per Table 12.2A Cd = 1.6 per Table 2.3.2 of 2018 NDS Ct = 1.0 per Table 10.3.4 of 2018 NDS W ' = 266 lbs/ in. x 2.5 in. x 1.6 x 1.0 = 1,064 lbs > 416 lbs OK Sht # 5 of 8 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022 2014 N Flower St 09/12/22 Check Seismic load due to added dead load of photovoltaic system. Determine Seismic Weight of Existing Building: Effective Existing Seismic Weight (main house) Area of (E) Building = Approximately 1,700 sq. ft. Approximate Effective Seismic Weight = 1,700 sq. ft. x 30 psf ave. = 51,000 LBS DETERMINE BASE SHEAR V = Cs W EQ'N 12.8-1 ASCE 7-16 Cs = SDS R l e EQ'N 12.8-2 ASCE 7-16 R = THE RESPONSE MODIFICATION FACTOR IN TABLE 12.2-1 R = 6.5 WOOD SHEAR WALLS e l = 1.0 IMPORTANCE FACTOR SDS = 2/3 x S MS EQ'N 11.4-3 ASCE 7-16 SMS = FA x SS EQ'N 11.4-1 ASCE 7-16 SMS = 1.2 x 1.5 = 1.8 SDS = 2/3 x 1.8 = 1.2 Cs = 1.2 6.5 1 = 0.185 EQ'N 12.8-2 ASCE 7-16 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224- 406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Sht # 6 of 8 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022 2014 N Flower St 09/12/22 EXISTING BASE SHEAR V = 0.185 x 51,000 LBS = 9,435 LBS EQ'N 12.8-1 ASCE 7-10 DETERMINE NEW BASE SHEAR Determine Seismic Weight of Building with Solar Array: EXISTING SEISMIC WEIGHT = 51,000 LBS NEW SOLAR ARRAY 3 PSF x 12 PANELS x 3.3' x 5.5' = 653 LBS= NEW SEISMIC WEIGHT = 51,000 LBS + 653 LBS = 51,653 LBS THEREFORE NEW BASE SHEAR: V = 0.185 x 51,653 = 9,556 LBS EQ'N 12.8-1 ASCE 7-10 % CHANGE =9,556 LBS - 9,435 LBS 9,435 LBS x 100 = 1.3 % < 10% OK Effective Existing Seismic Weight (garage) Area of (E) Building = Approximately 600 sq. ft. Approximate Effective Seismic Weight = 600 sq. ft. x 20 psf ave. = 12,000 LBS Sht # 7 of 8 Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224-406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022 2014 N Flower St 09/12/22 V = 0.185 x 12,000 LBS = 2,220 LBS EQ'N 12.8-1 ASCE 7-16 DETERMINE NEW BASE SHEAR Determine Seismic Weight of Building with Solar Array: EXISTING SEISMIC WEIGHT = 12,000 LBS NEW SOLAR ARRAY 3 PSF x 7 PANELS x 3.3' x 5.5' = 381 LBS= NEW SEISMIC WEIGHT = 12,000 LBS + 381 LBS = 12,381 LBS THEREFORE NEW BASE SHEAR: V = 0.185 x 12,381 = 2,291 LBS EQ'N 12.8-1 ASCE 7-16 % CHANGE = 2,291 LBS - 2,220 LBS 2,220 LBS x 100 = 3.2 % < 10% OK OK. PER ASCE 7-16 SECTION 11.B.3 ALTERATIONS EXISTING LATERAL FORCE RESISTING SYSTEM IS EXEMPT FROM ANALYSIS SINCE NEW SEISMIC FORCE IS LESS THAN 10% GREATER THAN EXISTING SEISMIC FORCE. "Alterations are permitted to be made to any structure without requiring the existing structure to comply with this standard provided the alterations comply with the requirements for a new structure. Alterations that increase the seismic force in any existing structural element by more than 10 percent or decrease the design strength of any existing structural element to resist seismic forces by more than 10 percent shall not be permitted unless the entire seismic force-resisting system is determined to comply with this standard for a new structure." End of Calculations EXISTING BASE SHEAR Loyd W. Martin Professional Engineer, Inc. 9924 Universal Boulevard #224- 406 Orlando, FL 32819 Tel:1.310.464.1804 Email: loydwmartin@gmail.com www.loydwmartin.com Sht # 8 of 8 Exp. 3-31-19 No. C58724 NITRAMW.DYO REGISTEREDPROFESSIONALENGINEER C V L FOETATS ALIFORNIAICIL 123 2022- 3209 Plug It In Solar Chad Barker Date: August 09, 2022 2014 N Flower St 09/12/22 Expedited Permit Process for PV Systems - AC Module1 Expedited Permit Process for PV Systems AC Module The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the AC Module to use with the Expedited Permit Process. The Standard String, Micro-Inverter, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 2014 N Flower St 09/12/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems AC Module The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 2014 N Flower St 09/12/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 AC Module Site Plan                                                          2014 N Flower St 09/12/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 AC Module Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for AC Module PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A CONDUIT SIZE N/A N/A N/A DESCRIPTIONTAG 1 2 3 4 5 6 7 PART NUMBER NOTES FOR UNUSED AC MODULES PUT "N/A” in BLANK ABOVE 1 2 2 3 EQUIPMENT SCHEDULE J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 5 6 7 5 3 4 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ AC MODULES IN BRANCH- CIRCUIT MOD __1__ DC AC MOD __1__ DC AC MOD __1__ DC AC ____ AC MODULES IN BRANCH- CIRCUIT MOD __1__ DC AC MOD __1__ DC AC MOD __1__ DC AC 1 2014 N Flower St 09/12/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for AC Module Electrical Diagram Contractor Name, Address and Phone: Bill Ted Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCY MAXIMUM AC POWER MAXIMUM AC CURRENT MAXIMUM OCPD RATING AC MODULE MAKE AC MODULE MODEL AC MODULE RATINGS (Guide Appendix C) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT (N/A) 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH AC MODULE CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ___oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR 6 OR LESS CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR AC MODULES INVERTER OUTPUT CIRCUITS WITH 12 AMPS OR LESS WHEN PROTECTED BY A 15- AMP OR SMALLER OCPD. b) 10 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR AC MODULES INVERTER OUTPUT CIRCUITS WITH 16 AMPS OR LESS WHEN PROTECTED BY A 20- AMP OR SMALLER OCPD. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix F): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) N/A since no dc wiring AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) 2014 N Flower St 09/12/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Luis Ocampo Digitally signed by Luis Ocampo DN: cn=Luis Ocampo, o, ou, email=Luis.Ocampo@plugitinsolar.com, c=US Date: 2022.08.02 13:57:38 -07'00' 2014 N Flower St 09/12/22