HomeMy WebLinkAbout2030 N Tustin Ave - Plan2030 N Tustin Ave. 16.0 kW DC SOLAR PHOTOVOLTAIC SYSTEM 2030 N Tustin Ave., Santa Ana, CA 92705 JPH G-1 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 5/27/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 SCOPE OF WORK SHEET INDEX PARCEL MAP NTS VICINITY MAP NTS AERIAL MAP NTS SIGNAGE INSTALLATION OF: (40) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 400 MODULES & (40) ENPHASE IQ7PLUS-72-2-US (208V) MICROINVERTER(S) STC RATING: 16.0 KW DC CEC RATING: 14.34 KW AC OCCUPANCY TYPE: B CONSTRUCTION TYPE: V-B AHJ: CITY OF SANTA ANA APN: 396-332-08 G-1 SCOPE OF WORK; SHEET INDEX; VICINITY MAP; NOTES; SIGNAGE G-2 PROPERTY PLAN G-3 ROOF PLAN; EQUIPMENT LOCATIONS S-1 ROOF FRAMING PLAN; ELEVATIONS; STRUCTURAL DETAILS; BRANCH CIRCUIT CONFIGURATION E-1 ELECTRICAL LINE DIAGRAM; ELECTRICAL CALCULATIONS Z-1 SPECIFICATIONS - MODULE, PV INVERTER, ELECTRICAL EQUIPMENT Z-2 SPECIFICATIONS - RACKING Z-3 SPECIFICATIONS - GROUNDING & BONDING ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: x 201 9 CBC / 201 8 IBC x 201 9 CRC / 201 8 IRC x 201 9 CEC / 201 7 NEC x 201 9 CMC / 201 8 UMC x 201 9 CPC / 201 8 UPC x 201 9 CFC / 201 8 IFC x 201 9 BUILDING ENERGY EFFICIENCY STANDARDS x 201 9 CALIFORNIA ENERGY CODE TITLE 24 x 201 9 CALIFORNIA HEALTH AND SAFETY CODE x CEC ARTICLE 690 x CFC ARTICLE 605.11 x IEEE STANDARD 929 x UL STANDARD 1741 x OSHA 29 CFR 1910.269 x WHERE APPLICABLE, RULES OF THE PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY x THE AUTHORITY HAVING JURISDICTION x MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS GOVERNING CODES NOTES GENERAL 1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM. 2. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. 4. CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 5. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF INVERTERS, MODULES, PV SOURCE CIRCUITS, BATTERY CONNECTIONS, ETC. AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL (CEC 690.4(E)). 6. THE CONTRACTOR OR OWNER MUST PROVIDE ROOF ACCESS (LADDER TO ROOF) FOR THE ALL REQUIRED INSPECTIONS. LADDERS MUST BE OSHA APPROVED, MINIMUM TYPE I WITH A 250 LB RATING, IN GOOD CONDITION AND DESIGNED FOR ITS INTENDED USE. 7. CONTRACTOR SHALL VERIFY THAT THE ROOF STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS. 8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT EXCEED MANUFACTURER RECOMMENDATIONS FOR FASTENERS INTO ENGINEERED STRUCTURAL MEMBERS. 9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. (CRC R331.4.2) 10. WHERE DC CONDUCTORS ARE RUN INSIDE BUILDING, THEY SHALL BE CONTAINED IN A METAL RACEWAY; THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT. (CEC 690.31(E)(1)) 11. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES - NO BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED, OBSTRUCTED OR ROUTED AROUND SOLAR MODULES. 12. ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS. ELECTRICAL 1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25°C AND MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET RATED AT 90°C. 2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV TYPE WIRE. 3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR-CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS 4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. (CEC 314.15) 5. WHERE CONDUCTORS ARE INSTALLED UNDERGROUND, SECTION 300.5 OF THE CEC MUST BE FOLLOWED TO ENSURE PROPER PROTECTION. 6. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. (CEC 250.90, 250.96) 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. (CEC 690.35(C)) 9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION. 10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC/EGC PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER G.E.C. VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN LUG, OR EQUIVALENT LISTED LUG. 12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT. 13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. 14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. (CEC 250.64(C)) 15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD". 16. WHEN APPLYING THE 120% RULE OF CEC 705.12(D)(2), THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER PER 705.12(D)(7). 17. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26(A) 18. RAPID SHUTDOWN REQUIREMENTS: PV SYSTEMS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION. PV SYSTEM CONDUCTORS OF MORE THAN 3 FT INSIDE A BUILDING, OR MORE THAN 1 FT FROM A PV ARRAY, SHALL BE LIMITED TO NOT MORE THAN 30 VOLTS AND 240 VA WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION, IN ACCORDANCE WITH CEC 690.12(A)-(D) TO BE PLACED JUNCTION BOXES, DISCONNECTS, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES; MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS: WARNING: PHOTOVOLTAIC POWER SOURCE PV SOLAR - AC DISCONNECT PV SYSTEM DC DISCONNECT RATED MAX POWER-POINT CURRENT - 10.8 A RATED POWER-POINT VOLTAGE - 37.1 V MAXIMUM SYSTEM VOLTAGE - 51.6 V SHORT CIRCUIT CURRENT - 13.9 A WARNING: ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 2030 N TUSTIN AVE., SANTA ANA, CA 92705 PV SOLAR ARRAY M CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: 32.2 A NORMAL OPERATING AC VOLTAGE: 208 V WARNING: THIS SERVICE METER IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM A TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: TO BE INSTALLED AT THE MAIN SERVICE PANEL, AC DISCONNECT, AND PV LOAD CENTER: TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE AND SUBPANELS: B C TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED TO BE INSTALLED ON THE INVERTER (GROUNDED SYSTEMS): E TO BE INSTALLED ON THE DC DISCONNECT: F TO BE INSTALLED AT THE DC DISCONNECT: TO BE INSTALLED AT THE AC DISCONNECT: PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS TO BE INSTALLED AT THE AC DISCONNECT: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT THE JUNCTION BOXES AND DC DISCONNECT (UNGROUNDED SYSTEMS): PV LOADS ONLY - DO NOT ADD ADDITIONAL LOADS TO BE INSTALLED AT THE DEDICATED PV LOAD CENTER: G H I J K L PV ARRAY JUNCTION BOX PV LOAD CENTER (WHEN PRESENT) AC DISCONNECT (WHEN PRESENT) MAIN SERVICE PANEL A H D J K B B C M SUBPANEL (WHEN PRESENT) B C D B L D N NI O N SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM TO BE PLACED AT THE RAPID SHUTDOWN/DISCONNECT: THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 9.5 MM (3∕M8 IN.) IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 4.8 MM (3∕M16 IN.) IN BLACK ON WHITE BACKGROUND TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: O SIGNAGE FORMAT: ALL LETTERS SHALL BE CAPITALIZED, 3/8" WHITE LETTERING ON RED BACKGROUND, ARIAL OR SIMILAR FONT, NON-BOLD; REFLECTIVE, ON WEATHER- RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING) WILL BE USED; DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. WHEN 120% RULE USED, TO BE INSTALLED NEXT TO THE BACKFED BREAKER AT MAIN ELECTRICAL SERVICE & SUBPANEL TIE-IN LOCATIONS: D1 WARNING - INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR WHEN 120% RULE IS NOT USED, TO BE INSTALLED NEXT TO THE BACKFED BREAKER AT MAIN ELECTRICAL SERVICE & SUBPANEL TIE-IN LOCATIONS: D2 SERVICE POINT & UTILITY METERING PV LOAD CENTER (ON ROOF) PV DISCONNECT FOR UTILITY OPERATION Bldg permit # 101111576 Plng approved by F. Arias Bldg approved by J.Lo on 9/20/22 Elect permit # 20177059 approved on 8/10/22 by M. Smith Permits issued on 1/10/23 2030 N Tustin Ave - 101111576 & 2017705901/10/23 JPH G-2 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 6/30/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 PROPERTY PLAN SCALE: 1" = 20' EXISTING STRUCTURE DRIVEWAY PROPERTY LINE OL D T U S T I N A V E . 388'-0" 247'-0" 107'-5" 114'-11" 34'-6" 2030 N TUSTIN 2010 N TUSTIN 2050 N TUSTIN DRIVEWAY EXISTING PARKING LOT EXISTING PARKING LOT EXISTING PARKING LOT 23'-11" 7'-9" 7'-10" 66'-4" N T U S T I N A V E . Unit A Unit B 2030 N Tustin Ave - 101111576 & 2017705901/10/23 (1) 5/16" x 4-3/4" SS LAG BOLT MIN. 2-1/2" EMBEDMENT FLASHFOOT-2 ALUMINUM FLASHING WITH INTEGRATED RUBBER BUSHING CAPFOOT NEOPRENE BONDED SEALING WASHER GROUNDING MODULE CLAMP IRONRIDGE XR10 RAIL JPH S-1 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 8/18/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 BRANCH CIRCUIT CONFIGURATION RAFTERS 2 x 10 @ 16" OCEXTERIOR WALL 1-LAYER COMPOSITION SHINGLE MODULE STRUCTURAL ATTACHMENT IRONRIDGE XR10 RAIL ELEVATION OF PV PANELS DOES NOT EXCEED THE HIGHEST POINT OF THE ROOF RIDGE, TYP STRUCTURAL INFORMATION SECTION ATTACHMENT DETAIL NTS NTS BUILDING IMAGE SCALE: 3/16" = 1'-0" PARTIAL FRAMING PLAN NTS BRANCH CIRCUIT DESIGNATIONS: BC1 = BRANCH CIRCUIT 1, ETC. BC1, BC2 BC1 SCALE: NTS 3" - 6" 24'-8" 34'-5" FOOTINGS @ MAX. 48" OC BC1 BC1 BC1 BC1 BC1 BC1 BC2 BC2 BC2 BC2BC2 BC2 BC2 BC3 BC3 BC3 BC3 BC3 BC3 BC4 BC4 BC4 BC4 BC4 BC4 BC4 BC5 BC5 BC5 BC5BC5 BC5 BC6 BC6 BC6 BC6 BC6 BC6 BC6 MODULE INSTALL LOCATION 11'-0"11'-0" 4'-0" R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2023 S T A T E O F C A L I F O R N I A 2*10)  64710) 2030 N Tustin Ave - 101111576 & 2017705901/10/23 (E) LOADS, TYP UTILITY SERVICE 120/208V 3ɐ/4W (E) 400A SECTION 208V 3ɐ/4W MAIN SWITCH (E) 400A 208V 3ɐ/4W UTILITY METER (N) PV OCPD 3P 50A (E) MAIN DISCONNECT 3P 400A FACILITY GROUND PER ART. 250 #1/0 GEC + #1/0 WATER PIPE BOND (E) 400A SECTION 208V 3ɐ/4W SWITCHBOARD 400A SUPPLY 2-POLE 208V BREAKERS TO BE PLACED ON ALTERNATING PHASES TO MAXIMALLY BALANCE ALL MICROINVERTERS ACROSS PHASES: A-B: 14 MICROINVERTERS B-C: 13 MICROINVERTERS A-C: 13 MICROINVERTERS (N) PV OCPD 2P 20A (N) PV LOAD CENTER (MIN) 125A 240V 3ɐ/4W MIN. 10,000 AIC (N) PV OCPD 2P 20A G (N) 60A 240V 3ɐ SOLAR AC DISCONNECT NON-FUSIBLE, LOCKABLE VISIBLE-BLADE, KNIFE-BLADE SQUARE D DU322RB OR EQUIV. 100,000 AIC RATED (N) PV OCPD 2P 20A (N) PV OCPD 2P 20A G TIE 2P BREAKERS ONTO ALTERNATING PHASES: AB/BC/AC (N) BRANCH CIRCUIT 1 : (7) MODULES PAIRED WITH (7) MICROINVERTERS (N) BRANCH CIRCUIT 2: (7) MODULES PAIRED WITH (7) MICROINVERTERS (N) BRANCH CIRCUIT 5: (6) MODULES PAIRED WITH (6) MICROINVERTERS (N) BRANCH CIRCUIT 6: (7) MODULES PAIRED WITH (7) MICROINVERTERS MODULES: (40) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 400 MICROINVERTERS: (40) ENPHASE IQ7PLUS-72-2-US (208V) [B] (MIN) XX" EMT * (6) #10 AWG THWN-2 WIRE (1) # 8 AWG THWN-2 EGC (N) BRANCH CIRCUIT 4: (7) MODULES PAIRED WITH (7) MICROINVERTERS (N) BRANCH CIRCUIT 3: (6) MODULES PAIRED WITH (6) MICROINVERTERS (N) PV OCPD 2P 20A (N) PV OCPD 2P 20A [A] WIRES IN FREE AIR * (2) #12 AWG WIRE IN ENGAGE Q-CABLE UV RATED SHEATHING ** #6 AWG BARE COPPER EGC [C] (MIN) 1 " EMT (4) #6 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC [D] (MIN) 1 " EMT (4) #6 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC (N) JBOX NEMA 3R G G (N) JBOX NEMA 3R [B] ELECTRICAL CALCULATIONS JPH E-1 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 5/27/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 ELECTRICAL LINE DIAGRAM NOTES: x MODULES ARE BONDED TO RAIL USING UL 2703 RATED BONDING SYSTEM - INTEGRATED BONDING MID-CLAMPS + DIRECT-BURIAL LAY-IN-LUGS; SEE ATTACHED FOR SPECIFICATIONS x PV DC SYSTEM IS UNGROUNDED x BACKFED PV BREAKER WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, SHEET F-1 x BARE COPPER IS TRANSITIONED TO THWN-2 VIA IRREVERSIBLE CRIMP; WHEN PRESENT, THE GEC TO BE CONTINUOUS AS PER CEC 250.64(C) x INVERTER(S) TO BE COMPLIANT WITH UL 1741 SUPPLEMENT A * THE ENPHASE IQ MICROINVERTER SYSTEM USES A DG TYPE CABLE AND CONTAINS ONLY TWO #12 AWG LINE CONDUCTORS. THE Q CABLE MALE CONNECTORS PLUG DIRECTLY INTO THE IQ MICROS, WHOSE DOUBLE INSULATION RATING REQUIRES NO NEUTRAL OR GROUND CONDUCTORS; LINE-TO-LINE COMMUNICATIONS INSTEAD OF THE NEUTRAL IS USED TO DETERMINE GRID VALUES. THIS FUNCTIONALITY IS PART OF ITS UL LISTING. ** GROUND PATH IS AS FOLLOWS: THE IQ MICRO AND THE IQ+ MICRO DO NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC); MICROINVERTER MOUNTING BRACKET IS BONDED VIA UL 2703 HARDWARE CONNECTION TO RACKING; INTEGRATED BONDING CLAMPS BOND MODULE FRAMES TO RACKING; RACKING IS BONDED TO BARE WIRE EGC VIA UL 2703 LISTED HARDWARE PHASE A PHASE C PHASE B HOT1 CIRCUIT 1 HOT2 HOT1 CIRCUIT 2 HOT2 HOT1 CIRCUIT 3 HOT2 HOT1 CIRCUIT 4 HOT2 HOT1 CIRCUIT 5 HOT2 HOT1 CIRCUIT 6 HOT2 2030 N Tustin Ave - 101111576 & 2017705901/10/23 PHOTOVOLTAIC MODULE SPECIFICATIONS JPH Z-1 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 5/26/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 UL 1741 SA COMPLIANCE AC DISCONNECT SPECIFICATIONS TRUNK CABLE SPECIFICATIONS INVERTER SPECIFICATIONS 2030 N Tustin Ave - 101111576 & 2017705901/10/23 JPH Z-2 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 5/26/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 RACKING ENGINEERING RACKING UL 2703 COMPLIANCERACKING ENGINEERING FOOTING SPECIFICATIONS 2030 N Tustin Ave - 101111576 & 2017705901/10/23 JPH Z-3 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 5/26/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 RACKING INTEGRATED GROUNDING COMPATIBILITYGROUNDING & BONDING SPECIFICATIONS MICROINVERTER GROUNDING CONSIDERATIONSGROUNDING & BONDING SPECIFICATIONS 2030 N Tustin Ave - 101111576 & 2017705901/10/23 2030 N Tustin Ave. 16.0 kW DC SOLAR PHOTOVOLTAIC SYSTEM 2030 N Tustin Ave., Santa Ana, CA 92705 JPH G-1 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 6/30/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 SCOPE OF WORK SHEET INDEX PARCEL MAP NTS VICINITY MAP NTS AERIAL MAP NTS SIGNAGE INSTALLATION OF: (40) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 400 MODULES & (40) ENPHASE IQ7PLUS-72-2-US (208V) MICROINVERTER(S) STC RATING: 16.0 KW DC CEC RATING: 14.34 KW AC OCCUPANCY TYPE: B CONSTRUCTION TYPE: V-B AHJ: CITY OF SANTA ANA APN: 396-332-08 G-1 SCOPE OF WORK; SHEET INDEX; VICINITY MAP; NOTES; SIGNAGE G-2 PROPERTY PLAN G-3 ROOF PLAN; EQUIPMENT LOCATIONS S-1 ROOF FRAMING PLAN; ELEVATIONS; STRUCTURAL DETAILS; BRANCH CIRCUIT CONFIGURATION E-1 ELECTRICAL LINE DIAGRAM; ELECTRICAL CALCULATIONS Z-1 SPECIFICATIONS - MODULE, PV INVERTER, ELECTRICAL EQUIPMENT Z-2 SPECIFICATIONS - RACKING Z-3 SPECIFICATIONS - GROUNDING & BONDING ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: · 2019 CBC / 2018 IBC · 2019 CRC / 2018 IRC · 2019 CEC / 2017 NEC · 2019 CMC / 2018 UMC · 2019 CPC / 2018 UPC · 2019 CFC / 2018 IFC · 2019 BUILDING ENERGY EFFICIENCY STANDARDS · 2019 CALIFORNIA ENERGY CODE TITLE 24 · 2019 CALIFORNIA HEALTH AND SAFETY CODE · CEC ARTICLE 690 · CFC ARTICLE 605.11 · IEEE STANDARD 929 · UL STANDARD 1741 · OSHA 29 CFR 1910.269 · WHERE APPLICABLE, RULES OF THE PUBLIC UTILITIES COMMISSION REGARDING SAFETY AND RELIABILITY · THE AUTHORITY HAVING JURISDICTION · MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS GOVERNING CODES NOTES GENERAL 1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM. 2. 110.2 APPROVAL: ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. 3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO INITIATING CONSTRUCTION. 4. CONTRACTOR SHALL REVIEW ALL MANUFACTURER INSTALLATION DOCUMENTS PRIOR TO INITIATING CONSTRUCTION. 5. ALL EQUIPMENT AND ASSOCIATED CONNECTIONS OF INVERTERS, MODULES, PV SOURCE CIRCUITS, BATTERY CONNECTIONS, ETC. AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL BE INSTALLED ONLY BY QUALIFIED PERSONNEL (CEC 690.4(E)). 6. THE CONTRACTOR OR OWNER MUST PROVIDE ROOF ACCESS (LADDER TO ROOF) FOR THE ALL REQUIRED INSPECTIONS. LADDERS MUST BE OSHA APPROVED, MINIMUM TYPE I WITH A 250 LB RATING, IN GOOD CONDITION AND DESIGNED FOR ITS INTENDED USE. 7. CONTRACTOR SHALL VERIFY THAT THE ROOF STRUCTURE WILL WITHSTAND THE ADDITIONAL LOADS. 8. LAG SCREWS SHALL PENETRATE A MINIMUM 2" INTO SOLID SAWN STRUCTURAL MEMBERS AND SHALL NOT EXCEED MANUFACTURER RECOMMENDATIONS FOR FASTENERS INTO ENGINEERED STRUCTURAL MEMBERS. 9. AN ACCESS POINT SHALL BE PROVIDED THAT DOES NOT PLACE THE GROUND LADDER OVER OPENINGS SUCH AS WINDOWS OR DOORS ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION AND IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. (CRC R331.4.2) 10. WHERE DC CONDUCTORS ARE RUN INSIDE BUILDING, THEY SHALL BE CONTAINED IN A METAL RACEWAY; THEY SHALL NOT BE INSTALLED WITHIN 10" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE COVERED BY THE PV MODULES AND EQUIPMENT. (CEC 690.31(E)(1)) 11. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES - NO BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED, OBSTRUCTED OR ROUTED AROUND SOLAR MODULES. 12. ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS. ELECTRICAL 1. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25°C AND MAXIMUM VOLTAGE AT 600V; WIRE SHALL BE WET RATED AT 90°C. 2. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV TYPE WIRE. 3. PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATE COLOR-CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS 4. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS. (CEC 314.15) 5. WHERE CONDUCTORS ARE INSTALLED UNDERGROUND, SECTION 300.5 OF THE CEC MUST BE FOLLOWED TO ENSURE PROPER PROTECTION. 6. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. (CEC 250.90, 250.96) 7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, CONTRACTOR SHALL SIZE THEM ACCORDING TO APPLICABLE CODES. 8. FOR GROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS. (CEC 690.35(C)) 9. FOR UNGROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION. 10. PV MODULE FRAMES SHALL BE BONDED TO RACKING RAIL OR BARE COPPER GEC/EGC PER THE MODULE MANUFACTURER'S LISTED INSTRUCTION SHEET. 11. PV MODULE RACKING RAIL SHALL BE BONDED TO BARE COPPER G.E.C. VIA WEEB LUG, ILSCO GBL-4DBT LAY-IN LUG, OR EQUIVALENT LISTED LUG. 12. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT. 13. RACKING AND BONDING SYSTEM TO BE UL2703 RATED. 14. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. (CEC 250.64(C)) 15. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD". 16. WHEN APPLYING THE 120% RULE OF CEC 705.12(D)(2), THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER PER 705.12(D)(7). 17. THE WORKING CLEARANCE AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26(A) 18. RAPID SHUTDOWN REQUIREMENTS: PV SYSTEMS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION. PV SYSTEM CONDUCTORS OF MORE THAN 3 FT INSIDE A BUILDING, OR MORE THAN 1 FT FROM A PV ARRAY, SHALL BE LIMITED TO NOT MORE THAN 30 VOLTS AND 240 VA WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION, IN ACCORDANCE WITH CEC 690.12(A)-(D) TO BE PLACED JUNCTION BOXES, DISCONNECTS, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES; MARKING SHALL BE PLACED ON INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES EVERY 10 FEET, WITHIN 1 FOOT OF TURNS OR BENDS AND WITHIN 1 FOOT ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS OR BARRIERS: WARNING: PHOTOVOLTAIC POWER SOURCE PV SOLAR - AC DISCONNECT PV SYSTEM DC DISCONNECT RATED MAX POWER-POINT CURRENT - 10.8 A RATED POWER-POINT VOLTAGE - 37.1 V MAXIMUM SYSTEM VOLTAGE - 51.6 V SHORT CIRCUIT CURRENT - 13.9 A WARNING: ELECTRIC SHOCK HAZARD TERMINALS ON BOTH THE LINE AND THE LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: 2030 N TUSTIN AVE., SANTA ANA, CA 92705 PV SOLAR ARRAY M CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: 32.2 A NORMAL OPERATING AC VOLTAGE: 208 V WARNING: THIS SERVICE METER IS ALSO SERVED BY A PHOTOVOLTAIC SYSTEM A TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: TO BE INSTALLED AT THE MAIN SERVICE PANEL, AC DISCONNECT, AND PV LOAD CENTER: TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE AND SUBPANELS: B C TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: WARNING: ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED TO BE INSTALLED ON THE INVERTER (GROUNDED SYSTEMS): E TO BE INSTALLED ON THE DC DISCONNECT: F TO BE INSTALLED AT THE DC DISCONNECT: TO BE INSTALLED AT THE AC DISCONNECT: PHOTOVOLTAIC DISCONNECT FOR UTILITY OPERATIONS TO BE INSTALLED AT THE AC DISCONNECT: WARNING: ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED IN THE OPEN POSITION TO BE INSTALLED AT THE JUNCTION BOXES AND DC DISCONNECT (UNGROUNDED SYSTEMS): PV LOADS ONLY - DO NOT ADD ADDITIONAL LOADS TO BE INSTALLED AT THE DEDICATED PV LOAD CENTER: G H I J K L PV ARRAY JUNCTION BOX PV LOAD CENTER (WHEN PRESENT) AC DISCONNECT (WHEN PRESENT) MAIN SERVICE PANEL A H D J K B B C M SUBPANEL (WHEN PRESENT) B C D B L D N NI O N SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM TO BE PLACED AT THE RAPID SHUTDOWN/DISCONNECT: THE TITLE “SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN” SHALL UTILIZE CAPITALIZED CHARACTERS WITH A MINIMUM HEIGHT OF 9.5 MM (3∕M8 IN.) IN BLACK ON YELLOW BACKGROUND, AND THE REMAINING CHARACTERS SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 4.8 MM (3∕M16 IN.) IN BLACK ON WHITE BACKGROUND TO BE INSTALLED AT THE MAIN ELECTRICAL SERVICE: O SIGNAGE FORMAT: ALL LETTERS SHALL BE CAPITALIZED, 3/8" WHITE LETTERING ON RED BACKGROUND, ARIAL OR SIMILAR FONT, NON-BOLD; REFLECTIVE, ON WEATHER- RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING) WILL BE USED; DURABLE ADHESIVE MATERIALS MEET THIS REQUIREMENT. WHEN 120% RULE USED, TO BE INSTALLED NEXT TO THE BACKFED BREAKER AT MAIN ELECTRICAL SERVICE & SUBPANEL TIE-IN LOCATIONS: D1 WARNING - INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR WHEN 120% RULE IS NOT USED, TO BE INSTALLED NEXT TO THE BACKFED BREAKER AT MAIN ELECTRICAL SERVICE & SUBPANEL TIE-IN LOCATIONS: D2 SERVICE POINT & UTILITY METERING PV LOAD CENTER (ON ROOF) PV DISCONNECT FOR UTILITY OPERATION 2030 N Tustin Ave - 101111576 & 2017705901/10/23 JPH G-2 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 6/30/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 PROPERTY PLAN SCALE: 1" = 20' EXISTING STRUCTURE DRIVEWAY PROPERTY LINE OL D T U S T I N A V E . 388'-0" 247'-0" 107'-5" 114'-11" 34'-6" 2030 N TUSTIN 2010 N TUSTIN 2050 N TUSTIN DRIVEWAY EXISTING PARKING LOT EXISTING PARKING LOT EXISTING PARKING LOT 23'-11" 7'-9" 7'-10" 66'-4" N T U S T I N A V E . 2030 N Tustin Ave - 101111576 & 2017705901/10/23 JB PVLC MP ACD JPH G-3 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 6/30/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 ROOF PLAN & EQUIPMENT LOCATIONS SCALE: 1/8" = 1'-0" FIRE ACCESS POINT FOR ACCESS LADDER PER CFC 605.11.1.1 (40) (N) SOLAR MODULES PAIRED WITH (40) (N) MICROINVERTERS TO BE MOUNTED UNDER ARRAY PITCH: 18° AZIMUTH: 270° TOTAL AREA OF ARRAY: 845 SQ. FT. OVER 1ST STORY COMPOSITION SHINGLE ROOF MP SERVICE POINT & UTILITY METERING CONDUIT RUN JB JUNCTION BOX 4' FIRE ACCESS PATHWAY ROOF VENTS, OBSTRUCTIONS CONDUIT TO BE RUN ON CONDUIT BLOCKS MIN. 1" ABOVE ROOF SURFACE, CLOSE TO RIDGE LINES, AND UNDER EAVES, AND/OR IN ATTIC; WIRING METHODS SHALL NOT BE INSTALLED WITHIN 18" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE DIRECTLY BELOW THE ROOF SURFACE COVERED BY PV MODULES. CIRCUITS SHALL BE RUN PERPENDICULAR TO THE ROOF PENETRATION POINT TO SUPPORTS A MINIMUM OF 18" BELOW THE ROOF DECKING PER CEC 690.31(E)(1); DC CONDUIT TO BE LABELED AT MAX 10' INTERVALS CONDUIT RUNS ARE APPROXIMATE AND ARE TO BE DETERMINED IN THE FIELD BY THE INSTALLERS FIRE ACCESS POINT FOR ACCESS LADDER PER CFC 605.11.1.1 EQUIPMENT LEGEND PVLC ACD DEDICATED PV LOAD CENTER AC DISCONNECT AC SUBPANELSUB WHERE EXPOSED, CONDUIT, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE OR HIP OR VALLEY AND FROM THE HIP OR VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. CONDUIT RUNS BETWEEN SUB ARRAYS AND TO DC COMBINER BOXES SHALL BE INSTALLED IN A MANNER THAT MINIMIZES THE TOTAL AMOUNT OF CONDUIT ON THE ROOF BY TAKING THE SHORTEST PATH FROM THE ARRAY TO THE DC COMBINER BOX. THE DC COMBINER BOXES SHALL BE LOCATED SUCH THAT CONDUIT RUNS ARE MINIMIZED IN THE PATHWAYS BETWEEN ARRAYS. DC WIRING SHALL BE INSTALLED IN METALLIC CONDUIT OR RACEWAYS WHEN LOCATED WITHIN ENCLOSED SPACES IN A BUILDING. CONDUIT SHALL RUN ALONG THE BOTTOM OF LOAD BEARING MEMBERS. ALL EXPOSED CONDUIT MUST BE PAINTED TO MATCH COLOR OF THE BUILDING DO NOT COVER MECHANICAL AND PLUMBING VENTS AT ROOF WITH SOLAR PV PANELS ELEVATION OF PV PANELS DOES NOT EXCEED THE HIGHEST POINT OF THE ROOF RIDGE; SEE S-1 FOR DETAIL NO OPERABLE WINDOWS ABOVE ROOF PLANES WHERE MODULES ARE LOCATED 18 ° 18 ° 4'-0" ACCESS PATHWAY, TYP 3'-0"FLAT ROOF (N) PV LOAD CENTER TO BE INSTALLED ON EXTERIOR WALL, ACCESSIBLE ON THE FLAT ROOF (E) ROOF ACCESS HATCH, TYP (N) PV AC DISCONNECT (INSIDE ELECTRICAL ROOM, GROUND LEVEL) (E) 400A SERVICE ENTRANCE AND MAIN SWITCHGEAR (INSIDE ELECTRICAL ROOM, GROUND LEVEL) (E) ELECTRICAL ROOM (1ST STORY, GROUND LEVEL) HAS ROOF ACCESS LADDER LEADING TO (E) ROOF ACCESS HATCH UNIT A UNIT B 2030 N Tustin Ave - 101111576 & 2017705901/10/23 (1) 5/16" x 4-3/4" SS LAG BOLT MIN. 2-1/2" EMBEDMENT FLASHFOOT-2 ALUMINUM FLASHING WITH INTEGRATED RUBBER BUSHING CAPFOOT NEOPRENE BONDED SEALING WASHER GROUNDING MODULE CLAMP IRONRIDGE XR10 RAIL JPH S-1 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 6/30/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 BRANCH CIRCUIT CONFIGURATION RAFTERSEXTERIOR WALL 1-LAYER COMPOSITION SHINGLE MODULE STRUCTURAL ATTACHMENT IRONRIDGE XR10 RAIL ELEVATION OF PV PANELS DOES NOT EXCEED THE HIGHEST POINT OF THE ROOF RIDGE, TYP STRUCTURAL INFORMATION SECTION ATTACHMENT DETAIL NTS NTS BUILDING IMAGE SCALE: 3/16" = 1'-0" PARTIAL FRAMING PLAN NTS BRANCH CIRCUIT DESIGNATIONS: BC1 = BRANCH CIRCUIT 1, ETC. BC1, BC2 BC1 SCALE: NTS 3" - 6" 24'-8" 34'-5" FOOTINGS @ MAX. 48" OC BC1 BC1 BC1 BC1 BC1 BC1 BC2 BC2 BC2 BC2BC2 BC2 BC2 BC3 BC3 BC3 BC3 BC3 BC3 BC4 BC4 BC4 BC4 BC4 BC4 BC4 BC5 BC5 BC5 BC5BC5 BC5 BC6 BC6 BC6 BC6 BC6 BC6 BC6 MODULE INSTALL LOCATION 2030 N Tustin Ave - 101111576 & 2017705901/10/23 (E) LOADS, TYP UTILITY SERVICE 120/208V 3ɸ/4W (E) 400A SECTION 208V 3ɸ/4W MAIN SWITCH (E) 400A 208V 3ɸ/4W UTILITY METER (N) PV OCPD 3P 50A (E) MAIN DISCONNECT 3P 400A FACILITY GROUND PER ART. 250 #1/0 GEC + #1/0 WATER PIPE BOND (E) 400A SECTION 208V 3ɸ/4W SWITCHBOARD 400A SUPPLY 2-POLE 208V BREAKERS TO BE PLACED ON ALTERNATING PHASES TO MAXIMALLY BALANCE ALL MICROINVERTERS ACROSS PHASES: A-B: 14 MICROINVERTERS B-C: 13 MICROINVERTERS A-C: 13 MICROINVERTERS (N) PV OCPD 2P 20A (N) PV LOAD CENTER (MIN) 125A 240V 3ɸ/4W MIN. 10,000 AIC (N) PV OCPD 2P 20A G (N) 60A 240V 3ɸ SOLAR AC DISCONNECT NON-FUSIBLE, LOCKABLE VISIBLE-BLADE, KNIFE-BLADE SQUARE D DU322RB OR EQUIV. 100,000 AIC RATED (N) PV OCPD 2P 20A (N) PV OCPD 2P 20A G TIE 2P BREAKERS ONTO ALTERNATING PHASES: AB/BC/AC (N) BRANCH CIRCUIT 1: (7) MODULES PAIRED WITH (7) MICROINVERTERS (N) BRANCH CIRCUIT 2: (7) MODULES PAIRED WITH (7) MICROINVERTERS (N) BRANCH CIRCUIT 5: (6) MODULES PAIRED WITH (6) MICROINVERTERS (N) BRANCH CIRCUIT 6: (7) MODULES PAIRED WITH (7) MICROINVERTERS MODULES: (40) HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 400 MICROINVERTERS: (40) ENPHASE IQ7PLUS-72-2-US (208V) [B] (MIN) XX" EMT * (6) #10 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC (N) BRANCH CIRCUIT 4: (7) MODULES PAIRED WITH (7) MICROINVERTERS (N) BRANCH CIRCUIT 3: (6) MODULES PAIRED WITH (6) MICROINVERTERS (N) PV OCPD 2P 20A (N) PV OCPD 2P 20A [A] WIRES IN FREE AIR * (2) #12 AWG WIRE IN ENGAGE Q-CABLE UV RATED SHEATHING ** #6 AWG BARE COPPER EGC [C] (MIN) 1" EMT (4) #6 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC [D] (MIN) 1" EMT (4) #6 AWG THWN-2 WIRE (1) #8 AWG THWN-2 EGC (N) JBOX NEMA 3R G G (N) JBOX NEMA 3R [B] ELECTRICAL CALCULATIONS JPH E-1 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 6/30/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 ELECTRICAL LINE DIAGRAM NOTES: · MODULES ARE BONDED TO RAIL USING UL 2703 RATED BONDING SYSTEM - INTEGRATED BONDING MID-CLAMPS + DIRECT-BURIAL LAY-IN-LUGS; SEE ATTACHED FOR SPECIFICATIONS · PV DC SYSTEM IS UNGROUNDED · BACKFED PV BREAKER WILL BE INSTALLED AT OPPOSITE END OF THE BUS BAR FROM THE MAIN BREAKER. A PERMANENT WARNING LABEL TO BE INSTALLED PER SYSTEM SIGNAGE, SHEET F-1 · BARE COPPER IS TRANSITIONED TO THWN-2 VIA IRREVERSIBLE CRIMP; WHEN PRESENT, THE GEC TO BE CONTINUOUS AS PER CEC 250.64(C) · INVERTER(S) TO BE COMPLIANT WITH UL 1741 SUPPLEMENT A * THE ENPHASE IQ MICROINVERTER SYSTEM USES A DG TYPE CABLE AND CONTAINS ONLY TWO #12 AWG LINE CONDUCTORS. THE Q CABLE MALE CONNECTORS PLUG DIRECTLY INTO THE IQ MICROS, WHOSE DOUBLE INSULATION RATING REQUIRES NO NEUTRAL OR GROUND CONDUCTORS; LINE-TO-LINE COMMUNICATIONS INSTEAD OF THE NEUTRAL IS USED TO DETERMINE GRID VALUES. THIS FUNCTIONALITY IS PART OF ITS UL LISTING. ** GROUND PATH IS AS FOLLOWS: THE IQ MICRO AND THE IQ+ MICRO DO NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC); MICROINVERTER MOUNTING BRACKET IS BONDED VIA UL 2703 HARDWARE CONNECTION TO RACKING; INTEGRATED BONDING CLAMPS BOND MODULE FRAMES TO RACKING; RACKING IS BONDED TO BARE WIRE EGC VIA UL 2703 LISTED HARDWARE PHASE A PHASE C PHASE B HOT1 CIRCUIT 1 HOT2 HOT1 CIRCUIT 2 HOT2 HOT1 CIRCUIT 3 HOT2 HOT1 CIRCUIT 4 HOT2 HOT1 CIRCUIT 5 HOT2 HOT1 CIRCUIT 6 HOT2 2030 N Tustin Ave - 101111576 & 2017705901/10/23 PHOTOVOLTAIC MODULE SPECIFICATIONS JPH Z-1 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 5/26/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 UL 1741 SA COMPLIANCE AC DISCONNECT SPECIFICATIONS TRUNK CABLE SPECIFICATIONS INVERTER SPECIFICATIONS 2030 N Tustin Ave - 101111576 & 2017705901/10/23 JPH Z-2 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 5/26/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 RACKING ENGINEERING RACKING UL 2703 COMPLIANCERACKING ENGINEERING FOOTING SPECIFICATIONS 2030 N Tustin Ave - 101111576 & 2017705901/10/23 JPH Z-3 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 5/26/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 RACKING INTEGRATED GROUNDING COMPATIBILITYGROUNDING & BONDING SPECIFICATIONS MICROINVERTER GROUNDING CONSIDERATIONSGROUNDING & BONDING SPECIFICATIONS 2030 N Tustin Ave - 101111576 & 2017705901/10/23 JB PV LC MP ACD JPH G-3 SHEET NUMBER: DRAWN BY: DATE: REV: 5/24/22 9/16/22 PROJECT: 2030 N TUSTIN AVE. 2030 N TUSTIN AVE., SANTA ANA, CA 92705 LICENSE HOLDER'S SIGNATURE CONTRACTOR: SUNKO SOLAR 1540 6TH ST. #304 SANTA MONICA, CA 90401 (415) 866-0676 CSLB # 1021907 C-46 ROOF PLAN & EQUIPMENT LOCATIONS SCALE: 1/8" = 1'-0" FIRE ACCESS POINT FOR ACCESS LADDER PER CFC 605.11.1.1 (40) (N) SOLAR MODULES PAIRED WITH (40) (N) MICROINVERTERS TO BE MOUNTED UNDER ARRAY PITCH: 18° AZIMUTH: 270° TOTAL AREA OF ARRAY: 845 SQ. FT. OVER 1ST STORY COMPOSITION SHINGLE ROOF MP SERVICE POINT & UTILITY METERING CONDUIT RUN JB JUNCTION BOX 4' FIRE ACCESS PATHWAY ROOF VENTS, OBSTRUCTIONS CONDUIT TO BE RUN ON CONDUIT BLOCKS MIN. 1" ABOVE ROOF SURFACE, CLOSE TO RIDGE LINES, AND UNDER EAVES, AND/OR IN ATTIC; WIRING METHODS SHALL NOT BE INSTALLED WITHIN 18" OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE DIRECTLY BELOW THE ROOF SURFACE COVERED BY PV MODULES. CIRCUITS SHALL BE RUN PERPENDICULAR TO THE ROOF PENETRATION POINT TO SUPPORTS A MINIMUM OF 18" BELOW THE ROOF DECKING PER CEC 690.31(E)(1); DC CONDUIT TO BE LABELED AT MAX 10' INTERVALS CONDUIT RUNS ARE APPROXIMATE AND ARE TO BE DETERMINED IN THE FIELD BY THE INSTALLERS FIRE ACCESS POINT FOR ACCESS LADDER PER CFC 605.11.1.1 EQUIPMENT LEGEND PVLC ACD DEDICATED PV LOAD CENTER AC DISCONNECT AC SUBPANELSUB WHERE EXPOSED, CONDUIT, WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE OR HIP OR VALLEY AND FROM THE HIP OR VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. CONDUIT RUNS BETWEEN SUB ARRAYS AND TO DC COMBINER BOXES SHALL BE INSTALLED IN A MANNER THAT MINIMIZES THE TOTAL AMOUNT OF CONDUIT ON THE ROOF BY TAKING THE SHORTEST PATH FROM THE ARRAY TO THE DC COMBINER BOX. THE DC COMBINER BOXES SHALL BE LOCATED SUCH THAT CONDUIT RUNS ARE MINIMIZED IN THE PATHWAYS BETWEEN ARRAYS. DC WIRING SHALL BE INSTALLED IN METALLIC CONDUIT OR RACEWAYS WHEN LOCATED WITHIN ENCLOSED SPACES IN A BUILDING. CONDUIT SHALL RUN ALONG THE BOTTOM OF LOAD BEARING MEMBERS. ALL EXPOSED CONDUIT MUST BE PAINTED TO MATCH COLOR OF THE BUILDING DO NOT COVER MECHANICAL AND PLUMBING VENTS AT ROOF WITH SOLAR PV PANELS ELEVATION OF PV PANELS DOES NOT EXCEED THE HIGHEST POINT OF THE ROOF RIDGE; SEE S-1 FOR DETAIL NO OPERABLE WINDOWS ABOVE ROOF PLANES WHERE MODULES ARE LOCATED 18 ° 18 ° 4'-0" ACCESS PATHWAY, TYP 4'-0"FLAT ROOF (N) PV LOAD CENTER TO BE INSTALLED ON EXTERIOR WALL, ACCESSIBLE ON THE FLAT ROOF (E) ROOF ACCESS HATCH, TYP (E) 400A SERVICE ENTRANCE AND MAIN SWITCHGEAR (INSIDE ELECTRICAL ROOM, GROUND LEVEL) (E) ELECTRICAL ROOM (1ST STORY, GROUND LEVEL) HAS ROOF ACCESS LADDER LEADING TO (E) ROOF ACCESS HATCH UNIT A UNIT B (N) PV AC DISCONNECT (INSIDE ELECTRICAL ROOM, GROUND LEVEL) MIN. 4" 2030 N Tustin Ave - 101111576 & 2017705901/10/23