Loading...
HomeMy WebLinkAbout2202 N Freeman St - Plan0 PV SYSTEM AS INDICATED JANUARY 11, 2022 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: COVER PAGE 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. 11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX 0 COVER PAGE PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE 3 4 ATTACHMENT LAYOUT5 INVERTER DATA SHEET D1 MODULE DATA SHEET RACKING DATA SHEET ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V ROOF PLAN RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV PAUL ZIESMER 22 HANWHA 340W Q.PEAK DUO BLK-G6+ 340 ENPHASE IQ7-60-2-US 22 2202 FREEMAN ST SANTA ANA, CA 92706 AC DisconnectACD SSP Service Sub Panel FLAT CONCRETE TILE 2,373 SQFT 00118226 CITY OF SANTA ANA WIRE SIZE CALCULATIONS D2 D3 D4 D5 D6 GROUNDING SPECS ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 7.48 KW DC 7.48 KW 6.79 KW AC (DOWNSIZED) EXISTING 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS 12. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 13. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER SEC 250.122 14. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 15. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 INTERNATIONAL RESIDENTIAL CODE 2019 INTERNATIONAL FIRE CODE IQ COMBINER BOX DATA SHEET 1 2 8,243 SQFT 1.1 SITE PLAN LG Chem Battery BackupLGB Solar Edge Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown Box RSB Itron MeterIM UNIT INDEX CODE REFERENCES ECOFASTEN CLICKFIT 2"X4" @ 24" O.CFRAMING OCCUPANCY: R ONE STORY BUILDING 175A 200A ATTACHMENT DATA SHEET Signed 1-11-22 Bldg permit #101109040 Elect permit #20175064 Plan approved by MS on 1/31/22 Issued on 2/8/22 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 2 SINGLE LINE DIAGRAM PV SYSTEM AS INDICATED JANUARY 11, 2022 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY # PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 1 4 3 1 8 15A 6 M MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY 22 HANWHA 340W Q.PEAK DUO BLK-G6+ 340 Voc = 40.66V Vmp = 33.94V Isc = 10.52A Imp = 10.02A 2 3 INVERTER PEAK PWR TRACKING VOLTAGE CEC EFFICIENCY PROTECTION RATING: MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER PEAK OUTPUT POWER 4 22 27-37 V 97.0 % NEMA 6 15.0 A 1.0 A 235-350 W 250 W Enphase Energy Microinverters (IQ7-60-2-US) IQ COMBINER ENPHASE IQ COMBINER BOX WITH ENPHASE ENVOY IQ 120/240V, NEMA 3R MODEL# X-IQ-AM1-240-3-ES INSTALL 15A PV 2-POLE C/B INSTALL 20A PV 2-POLE C/B 0 2 8 1 15A PV 2-POLE C/B (2)#14 AWG THWN-2 (L1+L2) (1)#14 AWG-NEUTRAL ENVOY INFORMATION 60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 17 PV LOAD CENTER PV LOAD CENTER 120/240 1P/3W 125A EXISTING (DOWNSIZED) PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AND COMPLIANT WITH NEC 690.12 Branch a: (13) Modules, (13) Microinverters 2 1 (D)175A 3 175A 200A 200A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 20A EXISTING CONDUIT EXISTING PHOTOVOLTAIC ARRAY 18 SOLAR WORLD 250W MODULES EXISTING SB 5000TL-US-22 SOLAR INVERTER EXISTING CONDUIT EXISTING CONDUIT M EXISTING PERFORMANCE METER EXISTING CONDUIT Branch b: (9) Modules, (9) Microinverters 20A 7 4 EXISTING CONDUIT EXISTING AC DISCONNECT INSTALL 2P 60A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB EXISTING JBOX 4 30A 30A RAPID SHUTDOWN RAPID SHUTDOWN Both system have Rapid Shutdowns 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 10.52 A CODE REQUIRED SIGNAGE 4 PV SYSTEM AS INDICATED JANUARY 11, 2022 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: 60 Hz 250 W N/A NEC 690.56(C)(3) DO NOT UPSIZE MAIN BREAKER. MAIN BREAKER WAS DOWNSIZED TO A TO ACCOMMODATE PV SYSTEM. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: NEC 705.10(B) & NEC 690.56(B) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. N 0° S 180° E 90° W 270° CONTACT EXO ENERGY SOLAR (888) 463-9667 JB B O X WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(f)(7) DC D i s c o n n e c t ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT NEC 690.53 NEC 690.13(B) In v e r t e r / P V L o a d WARNING THE DISCONNECTION OF THE GROUNDING CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(I) NEC 690.54 AC D i s c o n n e c t NEC 690.54 NEC 690.52 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) PM M E T E R NEC 705.12(D)(3) & NEC 690.59 Ma i n / S u b P a n e l NEC 690.54 NEC 690.13 (F), NEC 705.12(B)(3-4) & NEC 690.59 NEC 705.12(D)(3) & NEC 690.59 NEC 690.15 (C) & NEC 690.33(E)(2) NEC 690.13(B) SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUIT NEC 710.15(C) & 692.9 (C) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(f)(7) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) NEC 705.12 (B)(2)(c) LABELING REQUIREMENTS FOR ARTICLE 690 NEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether in the open (off) or closed (on) position and be permanently marked “PV SYSTEM DISCONNECT” or equivalent. Additional markings shall be permitted based upon the specific system configuration. For PV system disconnecting means where the line and load terminals may be energized in the open position, the device shall be marked with the following words or equivalent. NEC 690.13(F) Type of Disconnect. A dc PV system disconnecting means shall be marked for use in PV systems or be suitable for backfeed operation. NEC 690.15(C) An isolating device shall be rated to open the maximum circuit current under load or be marked “Do Not Disconnect Under Load” or “Not for Current Interrupting.” NEC 690.31(B)(1) PV system circuit conductors shall be identified at all accessible points of termination, connection and splices. The means of identification shall be permitted by separate color coding, marking tape, tagging or other approved means. NEC 690.31(G)(1) Where circuits are embedded in build up, laminate or membrane roofing materials not covered by PV modules and associated equipment, the location of the circuits shall be clearly marked. NEC 690.31(G)(4) PV dc system circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). Labels required in this section shall be suitable for the environment where they are installed. NEC 690.31(I) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. NEC 690.33(E)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a tool to open and marked “Do Not Disconnect Under Load” or “Not for Current Interrupting.” NEC 690.52 Alternating-current modules shall be marked with identification of terminals or leads and with identification of the following ratings. NEC 690.53A permanent label for the dc PV power source indicating items (1) through (3) shall be provided by the installer at dc PV system disconnecting means and at each dc equipment disconnecting means required by 690.15. Where a disconnecting means has more than one dc PV power source, the values in 690.53 (1) through (3) shall be specified for each source. NEC 690.54 All interactive system(s) points of interconnection with other sources shall be marked as an accessible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating ac voltage. NEC 690.55 The PV system output circuit conductors shall be marked to indicate polarity where connected to energy storage systems. NEC 690.56(B)Plaques or directories shall be installed in accordance with 705.10. NEC 690.56(C)(3) A rapid shutdown switch shall have a label located on or no more than 1 meter (3 ft) from the switch that includes the following wording. NEC 690.56(C)(1)(a-b) The type of PV system shall be labeled as described in a) or b): NEC 690.59 PV systems connected to other sources shall be installed in accordance with Parts I and II of Article 705. SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY IFC 605.11.3.1(1) & 690.56(C)(1)(a) NEC 690.56(C)(3) NEC 690.31(G)(3)(4) NEC 690.31(G)(1)CO N D U I T RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) DC DISCONNECT PHOTOVOLTAIC WARNING WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCY MAXIMUM AC POWER MAXIMUM AC CURRENT MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING DO NOT DISCONNECT UNDER LOAD RAPID SHUT DOWN SWITCH FOR SOLAR PV SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING PHOTOVOLTAIC POWER SOURCE DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW WARNING FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGH TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 45.5 V 240 Vac 240 Vac 240 Vac 240 Vac NEC 690.13(B) AC DISCONNECT PHOTOVOLTAIC 60 A 22.0 A 22.0 A 22.0 A 22.0 A Fr e e m a n S t 175 SERVICE POINT & UTILITY METERING PV SYSTEM DISCONNECT FOR UTILITY OPERATION PV LOAD CENTER IQ COMBINER BOX (E) SOLAR RS ARRAY ON THE ROOF (N) SOLAR RS ARRAY ON THE ROOF (N) SOLAR RS ARRAY ON THE ROOF 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 Wyssling Consulting 76 North Meadowbrook Drive Alpine, UT 84004 Scott E. Wyssling, PE, PP, CME office (201) 874-3483 swyssling@wysslingconsulting.com September 28, 2021 Current Insight P.O. Box 12924 Ogden, UT 84412 Re: Engineering Services Ziesmer Residence 2202 Freeman Street, Santa Ana CA 6.970 kW System To Whom It May Concern: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Current Insight representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by Current Insight and will be utilized for approval and construction of the proposed system. 3. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of a truss system with all chords constructed of 2 x 4 dimensional lumber at 24 center. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Doug-Fir #2 or better with standard construction components. The existing roofing material consists of tile shingles. Photos of the dwelling also indicate that there is a permanent foundation. A. Loading Criteria Used 95 MPH wind loading based on ASCE 7-16 Exposure Category C s of 18 degrees 7 PSF = Dead Load roofing/framing Live Load = 20 PSF Snow Load = 0 PSF 3 PSF = Dead Load solar panels/mounting hardware Total Dead Load =10 PSF The above values are within acceptable limits of recognized industry standards for similar structures in accordance with the 2019 California Building Code. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. 2202 N Freeman St 02/08/22 Page 2 of 2 B. Solar Panel Anchorage 1. EcoFasten Installation Manual e found on the EcoFasten website (http://EcoFasten.com/). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 lbs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Doug-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 ½ than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 ½ screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed no greater than 48 c. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2019 California Building Code, current industry standards, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE California License No. 83664 2202 N Freeman St 02/08/22 Wyssling Consulting 76 N. Meadowbrook Drive Alpine, UT 84004 (201) 874-3483 swyssling@wysslingconsulting.com Existing Roof Dead Load Ziesmer Residence 9.0 psf Clay or Conc Tile 2202 Freeman Street 2.5 psf 3/4" Plywood Sheathing Santa Ana, CA 0.8 psf 2x4 Roof Framing @ 24 in. o.c. 0.0 psf Ceiling, Mechanical, Electrical 0.6 psf Miscellaneous 13 psf TOTAL Second Floor Dead Load 0 psf Floor Finishes 0 psf 1 1/8" Subfloor Sheathing 0 psf Joists @ 16' o.c. 0 psf Partitions 0 psf Ceiling, Mechanical, Electrical 0 psf Miscellaneous 0 psf TOTAL Roof Live Load Floor Live Load 20 psf Reducible 0 psf Reducible Roof Snow Load pf = 0.7 x pg = 26 psf Flat Roof Snow Load (ASCE 7-16 Eq. 7.3-1) Additional Roof Dead Load 2.4929 psf Roof Live Load with Solar Panels 0 psf Roof Snow Load with Solar Panels 23 psf Sloped Roof Snow Load (ASCE 7-16 Eq. 7.4-1) Total Total Existing Roof Load = (DLROOF + LLROOF) AreaROOF = 106223 lbs Total New Roof Load = (DLROOF) AreaROOF + (DLADD) AreaADD + (LLROOF) (AreaROOF - AreaADD) = 106023 lbs Change in Demand = (Total New Roof Load - Existing Roof Load) / Existing Roof Load -0.19% Total New Gravity Loads are less than Existing Loads. OK 2018 IEBC Section 807.4 states: Gravity Loads "Existing structural elements supporting any additional gravity loads as a result of the alterations, including the effects of snow drift , shall comply with the International Building Code. EXCEPTION: 1. Structural elements whose stress is not increased by more than 5%." 2202 N Freeman St 02/08/22 Wyssling Consulting 76 N. Meadowbrook Drive Alpine, UT 84004 (201) 874-3483 swyssling@wysslingconsulting.com V = 95 Basic Wind Speed Exposure C ASCE 7-16, Section 26.7 Kz = 0.85 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 Kzt = 1 Topographic Factor, ASCE 7-16, Section 26.8.2 Kd = 0.85 Directionality Factor, ASCE 7-16, Section 26.6 Ke = 1 Ground Elevation Factor, ASCE 7-16, Section 26.9 qh = 16.7 psf ASCE 7-16 Eq. 26.10-1 Roof Q = 18 deg sanchor = 48 in Horizontal spacing of roof anchors Atrib = 6.81 sf Panel Area tributary to each roof anchor GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 Roof Zone Zone 1 2e 2n 2r 3e 3r -2.00 -2.00 -3.00 -3.00 -3.00 -3.60 ga = 0.80 Pressure Equalization Factor, ASCE 29.4.4 gE = 1.50 Edge Array Factor, ASCE 29.4.4 Assumes worst case loading pnet = qhGCpgEga =Design Wind Uplift Pressure, ASCE 7-16, Equation 30.4-1 Roof Zone 1 2e 2n 2r 3e 3r -40 psf -40 psf -60 psf -60 psf -60 psf -72 psf pnet = -16 psf Minimum Design Wind Pressure, ASCE 7-16, Section 30.2.2 Use 40 psf Use 40 psf Use 60 psf Use 60 psf Use 60 psf Use 72 psf ULTIMATE LOAD 24 psf 24 psf 36 psf 36 psf 36 psf 43 psf *0.6 ALLOWABLE LOAD Connection to Existing Roof Framing F.S. = 1 Additional Factor of Safety applied to withdrawl force, if desired Atrib = 6.8 ft2 DLpanel = 2.49 psf Roof Zone 1 2e 2n 2r 3e 3r Wuplift = 40 psf 40 psf 60 psf 60 psf 60 psf 72 psf Plag = F.S. x Atrib x (0.6D - 0.6W) =Withdrawl force for each roof anchor Roof Zone 1 2e 2n 2r 3e 3r -153.5 lbs -153.5 lbs -235.4 lbs -235.4 lbs -235.4 lbs -284.5 lbs Connection Capacity db = 5/16 in Lag Screw diameter Dpen = 2 1/2 in Lag Screw penetration into existing framing member No. of Screws 1 Screws per Connection Species of wood framing C D = 1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 Ct = 0.7 Temperature Factor, NDS Table 10.3.4 W = 266 lb/in Withdrawl Capacity, NDS Equation 11.2-1 W' = C D x Ct x W = 298 lb/in Adjusted withdrawl value Pallow = Dpen x W' = 745 lbs Roof Zone 1 2e 2n 2r 3e 3r DEMAND = 154 lbs 154 lbs 235 lbs 235 lbs 235 lbs 285 lbs CAPACITY = 745 lbs 745 lbs 745 lbs 745 lbs 745 lbs 745 lbs Max Load=0.382 OK Douglas Fir-Larch Wind Uplift Simplified Procedure for Componenets and Cladding ASCE 7-16, Section 29.4 2202 N Freeman St 02/08/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.Will the PV system weigh maximum 4 pounds per square feet or less? 5.Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.Will the PV system be installed without using any ballast system or counter-weight system? 8.Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 2202 Freeman Street, Santa Ana CA 92706 EXO Energy, Inc. 1063308 Timothy Walls 760-333-5537 9/28/21 Tim@goexoenergy.com 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 2202 N Freeman St 02/08/22 0 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: COVER PAGE 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. 11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX 0 COVER PAGE PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE 3 4 ATTACHMENT LAYOUT5 INVERTER DATA SHEET D1 MODULE DATA SHEET RACKING DATA SHEET ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1 !, 3W, 120/240V ROOF PLAN RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV PAUL ZIESMER 22 HANWHA 340W Q.PEAK DUO BLK-G6+ 340 ENPHASE IQ7-60-2-US 22 2202 FREEMAN ST SANTA ANA, CA 92706 AC DisconnectACD SSP Service Sub Panel FLAT CONCRETE TILE 2,373 SQFT 00118226 CITY OF SANTA ANA WIRE SIZE CALCULATIONS D2 D3 D4 D5 D6 GROUNDING SPECS ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 7.48 KW DC 7.48 KW 6.79 KW AC (DOWNSIZED) EXISTING 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS 12. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 13. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER SEC 250.122 14. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 15. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 INTERNATIONAL RESIDENTIAL CODE 2019 INTERNATIONAL FIRE CODE IQ COMBINER BOX DATA SHEET 1 2 8,243 SQFT 1.1 SITE PLAN LG Chem Battery BackupLGB Solar Edge Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown Box RSB Itron MeterIM UNIT INDEX CODE REFERENCES ECOFASTEN CLICKFIT 2"X4" @ 24" O.CFRAMING OCCUPANCY: R ONE STORY BUILDING 175A 200A ATTACHMENT DATA SHEET REVISED **Layout and module type change. AZ. 3/30/2022*** 2202 N Freeman St 03/30/22 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: IQ COMBINER BOX DATA SHEET D3 2202 N Freeman St 03/30/22 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: D4 RACKING DATA SHEET 2202 N Freeman St 03/30/22 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: ATTACHMENT DATA SHEET D5 2202 N Freeman St 03/30/22 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: D6 GROUNDING SPECS 2202 N Freeman St 03/30/22 1 ROOF PLAN PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: N 0° S 180° E 90° W 270° SCALE 0 5 1 10ft PHOTOVOLTAIC SYSTEM 22 Hanwha 340W Modules (Q.PEAK DUO BLK-G6+ 340) Enphase Energy Microinverters (IQ7-60-2-US)22 FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT7.48 KW DC ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.) - 4,340 SOLAR AREA (SQ.FT.) - (E) 324 + (N) 418 = 742 % OF COVERED AREA - 17.1% Solar Array 1 9 Hanwha Q.Peak 340W 9 IQ7 Microinverters Pitch: 20 Deg Orientation: 270 Deg Solar Array 2 3 Hanwha Q.Peak 340W 3 IQ7 Microinverters Pitch: 20 Deg Orientation: 180 Deg Solar Array 3 3 Hanwha Q.Peak 340W 3 IQ7 Microinverters Pitch: 20 Deg Orientation: 270 Deg Solar Array 5 7 Hanwha Q.Peak 340W 7 IQ7 Microinverters Pitch: 20 Deg Orientation: 180 Deg J/B Existing Solar System Fr e e m a n S t MSP ACD PV Gate Gate aa a a a aa a a a a a b b b bb b b IQ b a b 2202 N Freeman St 03/30/22 1.1 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: SITE PLAN N 0° S 180° E 90° W 270° SCALE Gate Gate POOL Fr e e m a n S t Pu b l i c S i d e w a l k Driveway 70' 135' 18' 6' 55' 19' MSP PROPERTY LINE 0 5 1 10ft ACD PV IQ 8' 2202 N Freeman St 03/30/22 2 SINGLE LINE DIAGRAM PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY # PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 1 4 3 1 8 15A 6 M MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY 22 HANWHA 340W Q.PEAK DUO BLK-G6+ 340 Voc = 40.66V Vmp = 33.94V Isc = 10.52A Imp = 10.02A 2 3 INVERTER PEAK PWR TRACKING VOLTAGE CEC EFFICIENCY PROTECTION RATING: MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER PEAK OUTPUT POWER 4 22 27-37 V 97.0 % NEMA 6 15.0 A 1.0 A 235-350 W 250 W Enphase Energy Microinverters (IQ7-60-2-US) IQ COMBINER ENPHASE IQ COMBINER BOX WITH ENPHASE ENVOY IQ 120/240V, NEMA 3R MODEL# X-IQ-AM1-240-3-ES INSTALL 15A PV 2-POLE C/B INSTALL 20A PV 2-POLE C/B 0 2 8 1 15A PV 2-POLE C/B (2)#14 AWG THWN-2 (L1+L2) (1)#14 AWG-NEUTRAL ENVOY INFORMATION 60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 17 PV LOAD CENTER PV LOAD CENTER 120/240 1P/3W 125A EXISTING (DOWNSIZED) PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AND COMPLIANT WITH NEC 690.12 Branch a: (13) Modules, (13) Microinverters 2 1 (D)175A 3 175A 200A 200A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 20A EXISTING CONDUIT EXISTING PHOTOVOLTAIC ARRAY 18 SOLAR WORLD 250W MODULES EXISTING SB 5000TL-US-22 SOLAR INVERTER EXISTING CONDUIT EXISTING CONDUIT M EXISTING PERFORMANCE METER EXISTING CONDUIT Branch b: (9) Modules, (9) Microinverters 20A 7 4 EXISTING CONDUIT EXISTING AC DISCONNECT INSTALL 2P 60A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB EXISTING JBOX 4 30A 30A 2202 N Freeman St 03/30/22 0 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: COVER PAGE 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. 11. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX 0 COVER PAGE PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE 3 4 ATTACHMENT LAYOUT5 INVERTER DATA SHEET D1 MODULE DATA SHEET RACKING DATA SHEET ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1 !, 3W, 120/240V ROOF PLAN RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV PAUL ZIESMER 22 HANWHA 340W Q.PEAK DUO BLK-G6+ 340 ENPHASE IQ7-60-2-US 22 2202 FREEMAN ST SANTA ANA, CA 92706 AC DisconnectACD SSP Service Sub Panel FLAT CONCRETE TILE 2,373 SQFT 00118226 CITY OF SANTA ANA WIRE SIZE CALCULATIONS D2 D3 D4 D5 D6 GROUNDING SPECS ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 7.48 KW DC 7.48 KW 6.79 KW AC (DOWNSIZED) EXISTING 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS 12. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 13. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER SEC 250.122 14. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 15. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA PLUMBING CODE 2019 INTERNATIONAL RESIDENTIAL CODE 2019 INTERNATIONAL FIRE CODE IQ COMBINER BOX DATA SHEET 1 2 8,243 SQFT 1.1 SITE PLAN LG Chem Battery BackupLGB Solar Edge Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown Box RSB Itron MeterIM UNIT INDEX CODE REFERENCES ECOFASTEN CLICKFIT 2"X4" @ 24" O.CFRAMING OCCUPANCY: R ONE STORY BUILDING 175A 200A ATTACHMENT DATA SHEET 2202 N Freeman St 03/30/22 1 ROOF PLAN PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: N 0° S 180° E 90° W 270° SCALE 0 5 1 10ft PHOTOVOLTAIC SYSTEM 22 Hanwha 340W Modules (Q.PEAK DUO BLK-G6+ 340) Enphase Energy Microinverters (IQ7-60-2-US)22 FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT7.48 KW DC ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.) - 4,340 SOLAR AREA (SQ.FT.) - (E) 324 + (N) 418 = 742 % OF COVERED AREA - 17.1% Solar Array 1 9 Hanwha Q.Peak 340W 9 IQ7 Microinverters Pitch: 20 Deg Orientation: 270 Deg Solar Array 2 3 Hanwha Q.Peak 340W 3 IQ7 Microinverters Pitch: 20 Deg Orientation: 180 Deg Solar Array 3 3 Hanwha Q.Peak 340W 3 IQ7 Microinverters Pitch: 20 Deg Orientation: 270 Deg Solar Array 5 7 Hanwha Q.Peak 340W 7 IQ7 Microinverters Pitch: 20 Deg Orientation: 180 Deg J/B Existing Solar System Fr e e m a n S t MSP ACD PV Gate Gate aa a a a aa a a a a a b b b bb b b IQ b a b 2202 N Freeman St 03/30/22 1.1 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: SITE PLAN N 0° S 180° E 90° W 270° SCALE Gate Gate POOL Fr e e m a n S t Pu b l i c S i d e w a l k Driveway 70' 135' 18' 6' 55' 19' MSP PROPERTY LINE 0 5 1 10ft ACD PV IQ 8' 2202 N Freeman St 03/30/22 2 SINGLE LINE DIAGRAM PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY # PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 1 4 3 1 8 15A 6 M MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY 22 HANWHA 340W Q.PEAK DUO BLK-G6+ 340 Voc = 40.66V Vmp = 33.94V Isc = 10.52A Imp = 10.02A 2 3 INVERTER PEAK PWR TRACKING VOLTAGE CEC EFFICIENCY PROTECTION RATING: MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER PEAK OUTPUT POWER 4 22 27-37 V 97.0 % NEMA 6 15.0 A 1.0 A 235-350 W 250 W Enphase Energy Microinverters (IQ7-60-2-US) IQ COMBINER ENPHASE IQ COMBINER BOX WITH ENPHASE ENVOY IQ 120/240V, NEMA 3R MODEL# X-IQ-AM1-240-3-ES INSTALL 15A PV 2-POLE C/B INSTALL 20A PV 2-POLE C/B 0 2 8 1 15A PV 2-POLE C/B (2)#14 AWG THWN-2 (L1+L2) (1)#14 AWG-NEUTRAL ENVOY INFORMATION 60AAC DISCONNECT NON FUSED AC DISCONNECT LOCKABLE, BLADE TYPE, NEMA 3R, 120/240V 16 17 PV LOAD CENTER PV LOAD CENTER 120/240 1P/3W 125A EXISTING (DOWNSIZED) PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN AND COMPLIANT WITH NEC 690.12 Branch a: (13) Modules, (13) Microinverters 2 1 (D)175A 3 175A 200A 200A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 20A EXISTING CONDUIT EXISTING PHOTOVOLTAIC ARRAY 18 SOLAR WORLD 250W MODULES EXISTING SB 5000TL-US-22 SOLAR INVERTER EXISTING CONDUIT EXISTING CONDUIT M EXISTING PERFORMANCE METER EXISTING CONDUIT Branch b: (9) Modules, (9) Microinverters 20A 7 4 EXISTING CONDUIT EXISTING AC DISCONNECT INSTALL 2P 60A CB(PV) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB EXISTING JBOX 4 30A 30A 2202 N Freeman St 03/30/22 22 22 340W * 340 Q.PEAK DUO BLK-G6+ 340 318.1W * 318.1 * 1.0 97% 1.0 0.97 IQ7-60-2-US (CEC)22 FROM JBOX TO IQ COMBINER BOX FROM IQ COMBINER BOX TO PV LOAD CENTER 1 1/2'' TEMP. DERATE FACTOR (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOF PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: 3 WIRE SIZE CALCULATIONSFROM PV MODULES TO JBOX #12 AWG ENPHASE TRUNK CABLE, PV WIRE(4) 1 (1) #6 AWG BARE CU EGC 2 #8 AWG CU EGC, (3) 3 (1) #8 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT WALL TEMPERATURE FACTOR OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT PV SYSTEM MAX AC OUTPUT 1.25 0.91 (4) (1) 22 Pmax (PTC Rating) 3/4'' EMT TYPE CONDUIT 3/4'' EMT TYPE CONDUIT #10 AWG THWN-2 WIRE CHART WIRE CHART a b 2 BRANCH CIRCUITS INVERTER OUTPUT MAX CURRENT COEFFICIENT 1.25 13 BRANCH CIRCUIT CURRENT a: 13 BREAKER SIZE PER BRANCH CRCT 20A 0.8ADJST. FACTOR (4 thru 6 WIRES) * *1.25131.0 16.3A ADJUSTED CONDUCTOR AMPACITY / / 16.3 0.58 0.8 35.1A NUMBER OF MICROINVERTERS 7.48KW 6.79KW WIRE CHART QTY CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS (A)1.25* *22 1.0 27.5 *1.25 / 0.91*22 1.0 30.2 #10 AWG THWN-2 TEMPERATURE ADJUSTMENT (A) 22 Attention!!!!!!! Need Calculation (don't delete this note) 9 BRANCH CIRCUIT CURRENT b: 9 BREAKER SIZE PER BRANCH CRCT 20A* *1.259 1.0 11.3A MAIN SERVICE PANEL RATING BUSBAR RATING MAIN BREAKER PV BACKFEED BREAKER SIZE 120% RULE: MAX ALLOWED FEED 60A 175A 200A 240A 175A''MB'' + 60A "SOLAR" = 235A ≤240A MAX (3) 4 (1) #8 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT (A) TEMPERATURE FACTOR TEMPERATURE ADJUSTMENT (A) 1.25 0.91 #6 AWG THWN-2 44.0 * 1.25 / 0.91 22.0 + 22.0 = 44.0 60.4 44.0 * 1.25 55.0 3/4'' EMT TYPE CONDUIT CONSIDER CONTINUOUS COEFFICIENT FROM PV LOAD CENTER TO MAIN SERVICE PANEL CONSIDER CONTINUOUS (A) 2202 N Freeman St 03/30/22 10.52 A CODE REQUIRED SIGNAGE 4 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: 60 Hz 250 W N/A NEC 690.56(C)(3) DO NOT UPSIZE MAIN BREAKER. MAIN BREAKER WAS DOWNSIZED TO A TO ACCOMMODATE PV SYSTEM. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: NEC 705.10(B) & NEC 690.56(B) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. N 0° S 180° E 90° W 270° CONTACT EXO ENERGY SOLAR (888) 463-9667 JB B O X WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(f)(7) DC D i s c o n n e c t ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT NEC 690.53 NEC 690.13(B) In v e r t e r / P V L o a d WARNING THE DISCONNECTION OF THE GROUNDING CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(I) NEC 690.54 AC D i s c o n n e c t NEC 690.54 NEC 690.52 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) PM M E T E R NEC 705.12(D)(3) & NEC 690.59 Ma i n / S u b P a n e l NEC 690.54 NEC 690.13 (F), NEC 705.12(B)(3-4) & NEC 690.59 NEC 705.12(D)(3) & NEC 690.59 NEC 690.15 (C) & NEC 690.33(E)(2) NEC 690.13(B) SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUIT NEC 710.15(C) & 692.9 (C) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(f)(7) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) NEC 705.12 (B)(2)(c) LABELING REQUIREMENTS FOR ARTICLE 690 NEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether in the open (off) or closed (on) position and be permanently marked —PV SYSTEM DISCONNECT“ or equivalent. Additional markings shall be permitted based upon the specific system configuration. For PV system disconnecting means where the line and load terminals may be energized in the open position, the device shall be marked with the following words or equivalent. NEC 690.13(F) Type of Disconnect. A dc PV system disconnecting means shall be marked for use in PV systems or be suitable for backfeed operation. NEC 690.15(C) An isolating device shall be rated to open the maximum circuit current under load or be marked —Do Not Disconnect Under Load“ or —Not for Current Interrupting.“ NEC 690.31(B)(1) PV system circuit conductors shall be identified at all accessible points of termination, connection and splices. The means of identification shall be permitted by separate color coding, marking tape, tagging or other approved means. NEC 690.31(G)(1) Where circuits are embedded in build up, laminate or membrane roofing materials not covered by PV modules and associated equipment, the location of the circuits shall be clearly marked. NEC 690.31(G)(4) PV dc system circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). Labels required in this section shall be suitable for the environment where they are installed. NEC 690.31(I) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. NEC 690.33(E)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a tool to open and marked —Do Not Disconnect Under Load“ or —Not for Current Interrupting.“ NEC 690.52 Alternating-current modules shall be marked with identification of terminals or leads and with identification of the following ratings. NEC 690.53A permanent label for the dc PV power source indicating items (1) through (3) shall be provided by the installer at dc PV system disconnecting means and at each dc equipment disconnecting means required by 690.15. Where a disconnecting means has more than one dc PV power source, the values in 690.53 (1) through (3) shall be specified for each source. NEC 690.54 All interactive system(s) points of interconnection with other sources shall be marked as an accessible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating ac voltage. NEC 690.55 The PV system output circuit conductors shall be marked to indicate polarity where connected to energy storage systems. NEC 690.56(B)Plaques or directories shall be installed in accordance with 705.10. NEC 690.56(C)(3) A rapid shutdown switch shall have a label located on or no more than 1 meter (3 ft) from the switch that includes the following wording. NEC 690.56(C)(1)(a-b) The type of PV system shall be labeled as described in a) or b): NEC 690.59 PV systems connected to other sources shall be installed in accordance with Parts I and II of Article 705. SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY IFC 605.11.3.1(1) & 690.56(C)(1)(a) NEC 690.56(C)(3) NEC 690.31(G)(3)(4) NEC 690.31(G)(1)CO N D U I T RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) DC DISCONNECT PHOTOVOLTAIC WARNING WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCY MAXIMUM AC POWER MAXIMUM AC CURRENT MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING DO NOT DISCONNECT UNDER LOAD RAPID SHUT DOWN SWITCH FOR SOLAR PV SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING PHOTOVOLTAIC POWER SOURCE DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW WARNING FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGH TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 45.5 V 240 Vac 240 Vac 240 Vac 240 Vac NEC 690.13(B) AC DISCONNECT PHOTOVOLTAIC 60 A 22.0 A 22.0 A 22.0 A 22.0 A Fr e e m a n S t 175 SERVICE POINT & UTILITY METERING SOLAR ARRAY ON THE ROOF SOLAR ARRAY ON THE ROOF SOLAR ARRAY ON THE ROOF SOLAR ARRAY ON THE ROOF PV SYSTEM DISCONNECT FOR UTILITY OPERATION PV LOAD CENTER IQ COMBINER BOX 2202 N Freeman St 03/30/22 ATTACHMENT LAYOUT 5 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: STRUCTURAL STAMPROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE FRAMING SIZE PENETRATION PATTERN 20° RACKING TYPE MAX PENETRATION SPACING ROOFING LAYERS WIND SPEED 110 MPH EXPOSURE C LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. MODULE WEIGHT (LBS) # OF MODULES TOTAL MODULE WEIGHT (LBS) RACK WEIGHT (LBS) TOTAL SYSTEM WEIGHT (LBS) # OF STANDOFFS LOADING PER STANDOFF (LBS) TOTAL MODULE AREA (SQ.FT.) LOADING (PSF) WEIGHT LOAD CALCULATION INDEX ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER SURFACE IS FACED WITH FELT PAPER TOTAL ROOF AREA (Sq. FT) % OF COVERED AREA PV MODULE MODEL # 43.9 Q.PEAK DUO BLK-G6+ 340 MICROINVERTER WEIGHT (LBS) 22 Roof 1 Layer Flat Concrete Tile EcoFasten Truss Staggered 48"2"X4" @ 24" O.C MIN 2.5" EMBEDMENT RACKING RAIL ATTACHMENT ROOF FRAMING Ecofasten Tile Flashing 5/16" X 4.0" ATTACHMENT DETAILS ROOF SHEETING WATERPROOF MEMBRAIN ROOF TILE SOLAR MODULE CUSTOMER SUPPLIED ATTACHMENT BRACKET ECOFASTEN RAIL FLASHING ECOFASTEN BASE PLATE 5/16"x4.0" LAG BOLT WITH 2 1/2"MIN THREAS PENETRATION 2''X6'' Blocking SOLAR MODULE ROOF ASCE 7-16 Max 3.5'' 68 418 4340 966 193 52 1211 17.8 2.90 9.6(NEW SYSTEM) 48"24" 2202 N Freeman St 03/30/22 D1 MODULE DATA SHEET PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: 2202 N Freeman St 03/30/22 INVERTER DATA SHEET PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: D2 2202 N Freeman St 03/30/22 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: IQ COMBINER BOX DATA SHEET D3 2202 N Freeman St 03/30/22 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: D4 RACKING DATA SHEET 2202 N Freeman St 03/30/22 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: ATTACHMENT DATA SHEET D5 2202 N Freeman St 03/30/22 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: D6 GROUNDING SPECS 2202 N Freeman St 03/30/22 10.52 A CODE REQUIRED SIGNAGE 4 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: 60 Hz 250 W N/A NEC 690.56(C)(3) DO NOT UPSIZE MAIN BREAKER. MAIN BREAKER WAS DOWNSIZED TO A TO ACCOMMODATE PV SYSTEM. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: NEC 705.10(B) & NEC 690.56(B) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipmenq or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacemet, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. N 0° S 180° E 90° W 270° CONTACT EXO ENERGY SOLAR (888) 463-9667 JB B O X WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(f)(7) DC D i s c o n n e c t ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT NEC 690.53 NEC 690.13(B) In v e r t e r / P V L o a d WARNING THE DISCONNECTION OF THE GROUNDING CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT NEC 690.31(I) NEC 690.54 AC D i s c o n n e c t NEC 690.54 NEC 690.52 WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) PM M E T E R NEC 705.12(D)(3) & NEC 690.59 Ma i n / S u b P a n e l NEC 690.54 NEC 690.13 (F), NEC 705.12(B)(3-4) & NEC 690.59 NEC 705.12(D)(3) & NEC 690.59 NEC 690.15 (C) & NEC 690.33(E)(2) NEC 690.13(B) SINGLE 120-VOLT SUPPLY DO NOT CONNECT MULTIWIRE BRANCH CIRCUIT NEC 710.15(C) & 692.9 (C) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL NEC 110.27(C) & OSHA 1910.145(f)(7) WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION NEC 690.13(B) NEC 705.12 (B)(2)(c) LABELING REQUIREMENTS FOR ARTICLE 690 NEC 690.13(B) Each PV system disconnecting means shall plainly indicate whether in the open (off) or closed (on) position and be permanently marked —PV SYSTEM DISCONNECT“ or equivalent. Additional markings shall be permitted based upon the specific system configuration. For PV system disconnecting means where the line and load terminals may be energized in the open position, the device shall be marked with the following words or equivalent. NEC 690.13(F) Type of Disconnect. A dc PV system disconnecting means shall be marked for use in PV systems or be suitable for backfeed operation. NEC 690.15(C) An isolating device shall be rated to open the maximum circuit current under load or be marked —Do Not Disconnect Under Load“ or —Not for Current Interrupting.“ NEC 690.31(B)(1) PV system circuit conductors shall be identified at all accessible points of termination, connection and splices. The means of identification shall be permitted by separate color coding, marking tape, tagging or other approved means. NEC 690.31(G)(1) Where circuits are embedded in build up, laminate or membrane roofing materials not covered by PV modules and associated equipment, the location of the circuits shall be clearly marked. NEC 690.31(G)(4) PV dc system circuit labels shall appear on every section of the wiring system that is separated by enclosures, walls, partitions, ceilings, or floors. Spacing between labels or markings, or between a label and a marking, shall not be more than 3 m (10 ft). Labels required in this section shall be suitable for the environment where they are installed. NEC 690.31(I) Solidly-grounded bipolar PV systems shall be clearly marked with a permanent, legible warning notice indicating that the disconnection of the grounded conductor(s) may result in overvoltage on the equipment. NEC 690.33(E)(2) Interruption of Circuit. Connectors shall be a type that requires the use of a tool to open and marked —Do Not Disconnect Under Load“ or —Not for Current Interrupting.“ NEC 690.52 Alternating-current modules shall be marked with identification of terminals or leads and with identification of the following ratings. NEC 690.53A permanent label for the dc PV power source indicating items (1) through (3) shall be provided by the installer at dc PV system disconnecting means and at each dc equipment disconnecting means required by 690.15. Where a disconnecting means has more than one dc PV power source, the values in 690.53 (1) through (3) shall be specified for each source. NEC 690.54 All interactive system(s) points of interconnection with other sources shall be marked as an accessible location at the disconnecting means as a power source and with the rated ac output current and the nominal operating ac voltage. NEC 690.55 The PV system output circuit conductors shall be marked to indicate polarity where connected to energy storage systems. NEC 690.56(B)Plaques or directories shall be installed in accordance with 705.10. NEC 690.56(C)(3) A rapid shutdown switch shall have a label located on or no more than 1 meter (3 ft) from the switch that includes the following wording. NEC 690.56(C)(1)(a-b) The type of PV system shall be labeled as described in a) or b): NEC 690.59 PV systems connected to other sources shall be installed in accordance with Parts I and II of Article 705. SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY IFC 605.11.3.1(1) & 690.56(C)(1)(a) NEC 690.56(C)(3) NEC 690.31(G)(3)(4) NEC 690.31(G)(1)CO N D U I T RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER (IF INSTALLED) DC DISCONNECT PHOTOVOLTAIC WARNING WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT NOMINAL OPERATING AC VOLTAGE NOMINAL OPERATING AC FREQUENCY MAXIMUM AC POWER MAXIMUM AC CURRENT MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION RATED AC OUTPUT CURRENT: NOMINAL OPERATING AC VOLTAGE: PHOTOVOLTAIC AC DISCONNECT WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM MAIN PHOTOVOLTAIC SYSTEM DISCONNECT WARNING CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING DO NOT DISCONNECT UNDER LOAD RAPID SHUT DOWN SWITCH FOR SOLAR PV SYSTEM WARNING: PHOTOVOLTAIC POWER SOURCE WARNING PHOTOVOLTAIC POWER SOURCE DO NOT REMOVE UNLESS REPLACED IN EXACT LOCATION - PV POWER CIRCUIT DIRECTLY BELOW WARNING FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGH TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 45.5 V 240 Vac 240 Vac 240 Vac 240 Vac NEC 690.13(B) AC DISCONNECT PHOTOVOLTAIC 60 A 22.0 A 22.0 A 22.0 A 22.0 A Fr e e m a n S t 175 SERVICE POINT & UTILITY METERING SOLAR ARRAY ON THE ROOF SOLAR ARRAY ON THE ROOF SOLAR ARRAY ON THE ROOF SOLAR ARRAY ON THE ROOF PV SYSTEM DISCONNECT FOR UTILITY OPERATION PV LOAD CENTER IQ COMBINER BOX 2202 N Freeman St 03/30/22 ATTACHMENT LAYOUT 5 PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: STRUCTURAL STAMPROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE FRAMING SIZE PENETRATION PATTERN 20° RACKING TYPE MAX PENETRATION SPACING ROOFING LAYERS WIND SPEED 110 MPH EXPOSURE C LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. MODULE WEIGHT (LBS) # OF MODULES TOTAL MODULE WEIGHT (LBS) RACK WEIGHT (LBS) TOTAL SYSTEM WEIGHT (LBS) # OF STANDOFFS LOADING PER STANDOFF (LBS) TOTAL MODULE AREA (SQ.FT.) LOADING (PSF) WEIGHT LOAD CALCULATION INDEX ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER SURFACE IS FACED WITH FELT PAPER TOTAL ROOF AREA (Sq. FT) % OF COVERED AREA PV MODULE MODEL # 43.9 Q.PEAK DUO BLK-G6+ 340 MICROINVERTER WEIGHT (LBS) 22 Roof 1 Layer Flat Concrete Tile EcoFasten Truss Staggered 48"2"X4" @ 24" O.C MIN 2.5" EMBEDMENT RACKING RAIL ATTACHMENT ROOF FRAMING Ecofasten Tile Flashing 5/16" X 4.0" ATTACHMENT DETAILS ROOF SHEETING WATERPROOF MEMBRAIN ROOF TILE SOLAR MODULE CUSTOMER SUPPLIED ATTACHMENT BRACKET ECOFASTEN RAIL FLASHING ECOFASTEN BASE PLATE 5/16"x4.0" LAG BOLT WITH 2 1/2"MIN THREAS PENETRATION 2''X6'' Blocking SOLAR MODULE ROOF ASCE 7-16 Max 3.5'' 68 418 4340 966 193 52 1211 17.8 2.90 9.6(NEW SYSTEM) 48"24" 2202 N Freeman St 03/30/22 D1 MODULE DATA SHEET PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: 2202 N Freeman St 03/30/22 INVERTER DATA SHEET PV SYSTEM AS INDICATED OCTOBER 15, 2021 PAUL ZIESMER 2202 FREEMAN ST SANTA ANA, CA 92706 CONTRACTOR Current Insight, LLC 2852 W. Amini Way South Jordan, UT 84095 EXO ENERGY Address: 1247 Simpson Way Escondido, CA 92029 Phone Number: 208-351-4153 CSLB:#1063308 Drafted By: D2 2202 N Freeman St 03/30/22 Revisions to: Permit #: 20175064 Pages affected: 0, 1, 1.1, 4, 5, Specs ● Layout changed ● Module type changed Thank you EXO Energy 1247 Simpson Way Escondido, CA 92029 Phone Number: 858-275-3627 2202 N Freeman St 03/30/22 2202 N Freeman St 02/08/22