HomeMy WebLinkAbout2401 N Hathaway St - Plan108'-9" 1 7 ' - 9 " 94 ' - 7 " 106'-5" 23'-7" 23 ' - 9 " 20'-7" 3'-0" MSPACD INV UM BAT BI PLP 1 PROJECT DESCRIPTION: PLOT PLAN & VICINITY MAP SCALE: 1/16" = 1'PV-1 SCALE: NTS PV-1 PLOT PLAN & VICINITY MAP 21X355 LONGI SOLAR:LR4-60HPB 355M 355W MODULE ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 7.46KW DC STC,6.0 kW AC CEC REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ARRAY LOCATIONS VICINITY MAP SCALE: NTSPV-1 2 HOUSE PHOTO EQUIPMENT SUMMARY 21 - LONGI SOLAR:LR4-60HPB 355M 355W MODULES 01 - SOLAREDGE TECHNOLOGY:SE6000H-US (240V) INVERTER 21 - SOLAREDGE POWER OPTIMIZER P-401 PROJECT SITE SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8 OPTIMIZER CHART PV-9+ EQUIPMENT SPECIFICATIONS 3 PAGE 1 OF 18 NOTES 1. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 2. MANUFACTURERS PRODUCT INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE AT THE TIME OF INSPECTION. 3. ALL SUBMITTALS WILL COMPLY WITH 2019 CEC, CBC, AND CFC. 4. SMOKE ALARMS AND CARBON MONOXIDE DETECTOR EQUIPMENT SHALL BE IN PLACE AT RESIDENCE ACCORDING TO THE CRC, CBC R314-315 REQUIREMENT. AHJ - SANTA ANA UTILITY - SCE ACCOUNT # - CA-R-185708 GOVERNING CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA RESIDENTIAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA FIRE CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. ROOF #03 (4) LONGI SOLAR LR4-60HPB 355M 355W MODULES (N) MAIN SERVICE PANEL, 225A RATED, 240V, (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT (E) UTILITY METER 1-STORY HOUSE EXISTING DRIVEWAY PROPERTY LINE PROP E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E ROOF ACCESS POINT N H A T H A W A Y S T ROOF #01 (3) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #02 (14) LONGI SOLAR LR4-60HPB 355M 355W MODULES (E) GATE (E) FENCE (N) BATTERY (N) BACKUP INTERFACE (N) PROTECTED LOAD PANEL Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Electrical, mechanical, architectural, and all other nonstructural aspects of the design are by others. VSE Project#: A0035-0215-221 August 17, 2022 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Elec# 20177169 MSmith Issued 06/08/23 Battery Back Up 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 108'-9" 1 7 ' - 9 " 94 ' - 7 " 106'-5" 23'-7" 23 ' - 9 " 20'-7" 3'-0" MSPACD INV UM 1 PROJECT DESCRIPTION: PLOT PLAN & VICINITY MAP SCALE: 1/16" = 1'PV-1 SCALE: NTS PV-1 PLOT PLAN & VICINITY MAP 21X355 LONGI SOLAR:LR4-60HPB 355M 355W MODULE ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 7.46KW DC STC,6.0 kW AC CEC REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ARRAY LOCATIONS VICINITY MAP SCALE: NTSPV-1 2 HOUSE PHOTO EQUIPMENT SUMMARY 21 - LONGI SOLAR:LR4-60HPB 355M 355W MODULES 01 - SOLAREDGE TECHNOLOGY:SE6000H-US (240V) INVERTER 21 - SOLAREDGE POWER OPTIMIZER P-401 PROJECT SITE SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8 OPTIMIZER CHART PV-9+ EQUIPMENT SPECIFICATIONS 3 PAGE 1 OF 15 NOTES 1. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 2. MANUFACTURERS PRODUCT INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE AT THE TIME OF INSPECTION. 3. ALL SUBMITTALS WILL COMPLY WITH 2019 CEC, CBC, AND CFC. 4. SMOKE ALARMS AND CARBON MONOXIDE DETECTOR EQUIPMENT SHALL BE IN PLACE AT RESIDENCE ACCORDING TO THE CRC, CBC R314-315 REQUIREMENT. AHJ - SANTA ANA UTILITY - SCE ACCOUNT # - CA-R-185708 GOVERNING CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA RESIDENTIAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA FIRE CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. ROOF #03 (3) LONGI SOLAR LR4-60HPB 355M 355W MODULES (N) MAIN SERVICE PANEL, 225A RATED, 240V, (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT (E) UTILITY METER 1-STORY HOUSE EXISTING DRIVEWAY PROPERTY LINE PROP E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E ROOF ACCESS POINT N H A T H A W A Y S T ROOF #01 (3) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #02 (15) LONGI SOLAR LR4-60HPB 355M 355W MODULES (E) GATE (E) FENCE BLDG # 101108961 ELEC # 20175012 ISSUED: 12/22/2021 2401 N Hathaway 08/17/22 108'-9" 1 7 ' - 9 " 94 ' - 7 " 106'- 5" 23'-7" 23 ' - 9 " 20'-7" 3'-0" MSPACD UM BAT BI PLP INVDCD 1 PROJECT DESCRIPTION: PLOT PLAN & VICINITY MAP SCALE: 1/16" = 1'PV-1 SCALE: NTS PV-1 PLOT PLAN & VICINITY MAP 21X355 LONGI SOLAR:LR4-60HPB 355M 355W MODULE ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 7.46KW DC STC,6.0 kW AC CEC REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV D11/17/2022 REV ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ARRAY LOCATIONS VICINITY MAP SCALE: NTSPV-1 2 HOUSE PHOTO EQUIPMENT SUMMARY 21 - LONGI SOLAR:LR4-60HPB 355M 355W MODULES 01 - SOLAREDGE TECHNOLOGY:SE6000H-US (240V) INVERTER 21 - SOLAREDGE POWER OPTIMIZER P-401 PROJECT SITE SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-5A EQUIPMENTS ELEVATION PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8 OPTIMIZER CHART PV-9-18 EQUIPMENT SPECIFICATIONS PV-19 PANEL SCHEDULE 3 PAGE 1 OF 19 NOTES 1. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 2. MANUFACTURERS PRODUCT INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE AT THE TIME OF INSPECTION. 3. ALL SUBMITTALS WILL COMPLY WITH 2019 CEC, CBC, AND CFC. 4. SMOKE ALARMS AND CARBON MONOXIDE DETECTOR EQUIPMENT SHALL BE IN PLACE AT RESIDENCE ACCORDING TO THE CRC, CBC R314-315 REQUIREMENT. AHJ - SANTA ANA UTILITY - SCE ACCOUNT # - CA-R-185708 GOVERNING CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA PLUMBING CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. ROOF #03 (4) LONGI SOLAR LR4-60HPB 355M 355W MODULES (N) MAIN SERVICE PANEL, 225A RATED, 240V, (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT (E) UTILITY METER 1-STORY HOUSE EXISTING DRIVEWAY PROPERTY LINE PROP E R T Y L I NE PR O P E R T Y L I N E PR O P E R T Y L I N E ROOF ACCESS POINT N H A T H A W A Y S T ROOF #01 (3) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #02 (14) LONGI SOLAR LR4-60HPB 355M 355W MODULES (E)GATE (E)FENCE (N)BATTERY (INTERIOR) (N) BACKUP INTERFACE (N) PROTECTED LOAD PANEL (N) DC DISCONNECT Signed 3/9/2023 Structural Only 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 Expedited Permit Process for PV Systems 1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. Expedited Permit Process for PV Systems 2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan               E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram                                                                                                            E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date:SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THEREQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THEREQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAXCURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTEROCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTALSUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)?YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEANEXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TOINSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHESTMONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TOINSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT ATLEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLERFUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULESWITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLERFUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV ELECTRICAL LINE DIAGRAM MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 225A (NEW) NORTH (21 ) LONGI SOLAR LR4-60HPB 355M 355W MODULES (01) SOLAREDGE TECHNOLOGY:SE6000H-US (240V) (21) SOLAREDGE POWER OPTIMIZER P-401 (1) STRING OF 11 MODULES CONNECTED IN SERIES. (1) STRING OF 10 MODULES CONNECTED IN SERIES. SCALE: NTSPV-5 1 ELECTRICAL LINE DIAGRAM Tag # THWN-2 - Ground Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) THWN-2 1 1 2 2 3 Bare Copper Ground (EGC/GEC) THWN-2 PV WIRE 10 AWG 8 AWG THWN-2 - Ground Description Wire Gauge # of Conductors/Color 10 AWG 6 AWG 8 AWG 8 AWG 4 (2V+, 2V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) 3 INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(a) UTILITY FEED + SOLAR BACKFEED 200A + 35A = 235A BUSS RATING x 120% 225A x 120% = 270A 5 L1 L2 N G = ACDC 5 200 A (NEW) JUNCTION BOX 600 V, NEMA 3 UL LISTED 2 1 SolarEdge Power Optimizer P 401 Rated DC Input Power - 401 watts Maximum Input Voltage - 60 Vdc MPPT Range - 8 to 60 Vdc Maximum Input Current - 14.65 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5700 watts STC per string maximum PAGE 5 OF 18 LONGI SOLAR LR4-60HPB 355M 355W MODULES Conduit Type Conduit Size EMT 3/4" 3/4" 3/4" 3/4" EMT EMT EMT INSIDE EMT-ON ROOF INSIDE EMT-ON ROOF 3/4" 3/4" GEC BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V UTILITY PROVIDER :- SCE UTILITY METER # :- 222013-566114 (N) MAIN BREAKER TO HOUSE 240V, 200A/2P, (TOP FED) (N) MAIN SERVICE PANEL, 225A RATED, 240V G N NL2L1 M TO UTILITY GRID 200A 100A/2P (N) 100A/2P BREAKER GROUNDING ELECTRODE SYSTEM L1 L2 L1 L2 N G N G AC DISCONNECT EATON#DG223URB 100A, 2P,600VAC NEMA 3R SOLAREDGE TECHNOLOGY: SE6000H-US OUTPUT: 240 VAC, 25A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT & INTEGRATED RAPID SHUTDOWN SERVICE INFO UTILITY PROVIDER: SCE OVERHEAD SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 7.46 kW DC TOTAL AC SYSTEM SIZE: 6.0 kW AC N/A 10 - + - + + - + + + + - - - 2 - + - 1 3 = = = = = = = = = = 11 09 - + - + + - + + + + - - - 2 - + - 1 3 = = = = = = = = = = 10 LG CHEM RESU16H BATTERY DC 4 THWN-2 4 THWN-2 - Ground 10 AWG 8 AWG 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) 4 3/4" 3/4" EMT EMT (N) BACKUP INTERFACE BI-NUSGN-01 30A (N) PROTECTED LOAD PANEL 100A 15A #2 AWG CU WIRE 100A 200A CT NOTE:- · LOADS ARE RELOCATED FROM THE MAIN SERVICE PANEL · 35A PV BACKFEED IN BACKUP INTERFACE · THE BATTERY IS FOR BACKUP PURPOSES THWN-2 5 THWN-2 - Ground 2 AWG 8 AWG 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) 5 3/4" 3/4" EMT EMT 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV D11/17/2022 REV ELECTRICAL LINE DIAGRAM MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 225A (NEW) NORTH (21 ) LONGI SOLAR LR4-60HPB 355M 355W MODULES (01) SOLAREDGE TECHNOLOGY:SE6000H-US (240V) (21) SOLAREDGE POWER OPTIMIZER P-401 (1) STRING OF 11 MODULES CONNECTED IN SERIES. (1) STRING OF 10 MODULES CONNECTED IN SERIES. SCALE: NTSPV-5 1 ELECTRICAL LINE DIAGRAM Tag # THWN-2 - Ground Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) THWN-2 1 1 2 2 3 Bare Copper Ground (EGC/GEC) THWN-2 PV WIRE 10 AWG 8 AWG THWN-2 - Ground Description Wire Gauge # of Conductors/Color 10 AWG 6 AWG 6 AWG 8 AWG 4 (2V+, 2V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) 3 INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(a) UTILITY FEED + SOLAR BACKFEED 200A + 35A = 235A BUSS RATING x 120% 225A x 120% = 270A 5 L1 L2 N G = ACDC 5 200 A (NEW) JUNCTION BOX 600 V, NEMA 3 UL LISTED 2 1 SolarEdge Power Optimizer P 401 Rated DC Input Power - 401 watts Maximum Input Voltage - 60 Vdc MPPT Range - 8 to 60 Vdc Maximum Input Current - 14.65 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5700 watts STC per string maximum PAGE 5 OF 19 LONGI SOLAR LR4-60HPB 355M 355W MODULES Conduit Type Conduit Size EMT 3/4" 3/4" 3/4" 3/4" EMT EMT EMT INSIDE EMT-ON ROOF INSIDE EMT-ON ROOF 3/4" 3/4" GEC BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V UTILITY PROVIDER :- SCE UTILITY METER # :- 222013-566114 (N) MAIN BREAKER TO HOUSE 240V, 200A/2P, (TOP FED) (N) MAIN SERVICE PANEL, 225A RATED, 240V G N NL2L1 M TO UTILITY GRID 200A 100A/2P (N) 100A/2P BREAKER GROUNDING ELECTRODE SYSTEM L1 L2 L1 L2 N G N G AC DISCONNECT EATON#DG223URB 100A, 2P,240VAC NEMA 3R SOLAREDGE TECHNOLOGY: SE6000H-US OUTPUT: 240 VAC, 25A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT & INTEGRATED RAPID SHUTDOWN SERVICE INFO UTILITY PROVIDER: SCE OVERHEAD SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 7.46 kW DC TOTAL AC SYSTEM SIZE: 6.0 kW AC N/A 10 - + - + + - + ++ + - - - 2 - + - 1 3 = = = = = = = = = = 11 09 - + - + + - + + + +- - - 2 - + - 1 3 = = = = = = = = = = 10 LG CHEM RESU16H BATTERY DC 4 THWN-2 4 THWN-2 - Ground 8 AWG 8 AWG 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) 4 3/4" 3/4" EMT EMT (N) BACKUP INTERFACE BI-NUSGN-01 20A (N) PROTECTED LOAD PANEL 100A 15A 100A 200A CT NOTE:- · LOADS ARE RELOCATED FROM THE MAIN SERVICE PANEL · 35A PV BACKFEED IN BACKUP INTERFACE · THE BATTERY IS FOR BACKUP PURPOSES THWN-2 5 THWN-2 - Ground 2 AWG 6 AWG 3 (1L1, 1L2, 1N) B/R/W 1 (GRN) 5 1-1/2" 1-1/2" EMT EMT L1L2 L1L2G G 4 D C D I S C O N N E C T 60 A , 2 P , 6 0 0 V A C NE M A 3 R (N) 100A/2P MAIN BREAKER TO PROTECTED LOAD PANEL G N 5 3 NOTE:- APPROVED MAIN SERVICE PANEL TO BE INSTALLED AT SITE.A 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022REV B03/11/2022REV C03/14/2022REV PLACARDS NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2019: 705.12(D)(3), NEC 2017: 705.12(D)(3), NEC 2011: 705.12(D)(4) DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(D)(2)(3)(c), NEC 2017: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): CEC 2019: 690.5(C), NEC 2017: 690.5(C), NEC 2011: 690.5(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 25 .00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2011: 690.54 THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING ! LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): CEC 2019: 690.35(F), NEC 2017: 690.35(F), NEC 2011: 690.35(F) ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.17(E), NEC 2017: 690.17(E), NEC 2011: 690.17(4) WARNING! WARNING! WARNING! PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1) LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53, NEC 2011: 690.53 INVERTER #1 SOLAREDGE MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX. RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC- CONVERTER (IF INSTALLED) 480VDC 30.0ADC 19.62ADC PAGE 7 OF 18 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b), NEC 2011: 705.12(D)(7) WARNING ! CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN UTILITY METER & MAIN SERVICE PANEL AC DISCONNECT INVERTER (N) INVERTER (N) AC DSCONNECT (E) UTILITY METER (E) MAIN SERVICE PANEL 24 0 1 N H A T H A W A Y S T (N) BATTERY (N) BACKUP INTERFACE (N) PROTECTED LOAD PANEL 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN ELECTRICAL LINE DIAGRAM MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 225A (NEW) NORTH (21 ) LONGI SOLAR LR4-60HPB 355M 355W MODULES (01) SOLAREDGE TECHNOLOGY:SE6000H-US (240V) (21) SOLAREDGE POWER OPTIMIZER P-401 (1) STRING OF 13 MODULES CONNECTED IN SERIES. (1) STRING OF 8 MODULES CONNECTED IN SERIES. SCALE: NTSPV-5 1 ELECTRICAL LINE DIAGRAM Tag # THWN-2 - Ground Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) THWN-2 1 1 2 2 3 Bare Copper Ground (EGC/GEC) THWN-2 PV WIRE 10 AWG 8 AWG THWN-2 - Ground Description Wire Gauge # of Conductors/Color 10 AWG 6 AWG 8 AWG 8 AWG 4 (2V+, 2V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 3 (1L1, 1L2, 1N) B/R/W 1 (GRN)3 INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(a) UTILITY FEED + SOLAR BACKFEED 200A + 40A = 240A BUSS RATING x 120% 225A x 120% = 270A 3 L1 L2 N G = ACDC 3 200 A (NEW) JUNCTION BOX 600 V, NEMA 3 UL LISTED 2 1 SolarEdge Power Optimizer P 401 Rated DC Input Power - 401 watts Maximum Input Voltage - 60 Vdc MPPT Range - 8 to 60 Vdc Maximum Input Current - 14.65 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5700 watts STC per string maximum PAGE 5 OF 15 LONGI SOLAR LR4-60HPB 355M 355W MODULES Conduit Type Conduit Size EMT 3/4" 3/4" 3/4" 3/4" EMT EMT EMT INSIDE EMT-ON ROOF INSIDE EMT-ON ROOF 3/4" 3/4" GEC BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V UTILITY PROVIDER :- SCE UTILITY METER # :- 222013-566114 (N) MAIN BREAKER TO HOUSE 240V, 200A/2P, (TOP FED) (N) MAIN SERVICE PANEL, 225A RATED, 240V (NEW SIEMENS MC4040B1200SECW) G N NL2L1 M TO UTILITY GRID 200A 40A/2P (N) 40A/2P PV BREAKER AS FAR AS POSSIBLE FROM THE MAIN BREAKER GROUNDING ELECTRODE SYSTEM L1 L2 L1 L2 N G N G AC DISCONNECT EATON#DG221URB 60A, 2P,600VAC NEMA 3R SOLAREDGE TECHNOLOGY: SE6000H-US OUTPUT: 240 VAC, 25A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT & INTEGRATED RAPID SHUTDOWN SERVICE INFO UTILITY PROVIDER: SCE OVERHEAD SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 7.46 kW DC TOTAL AC SYSTEM SIZE: 6.0 kW AC SIEMENS MC4040B1200SECW 12 - + - + + - + + + + - - - 2 - + - 1 3 = = = = = = = = = = 13 07 - + - + + - + + + +- - - 2 - + - 1 3 = = = = = = = = = = 08 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN PLACARDS NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2019: 705.12(D)(3), NEC 2017: 705.12(D)(3), NEC 2011: 705.12(D)(4) DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(D)(2)(3)(c), NEC 2017: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): CEC 2019: 690.5(C), NEC 2017: 690.5(C), NEC 2011: 690.5(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 25 .00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2011: 690.54 THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING ! LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): CEC 2019: 690.35(F), NEC 2017: 690.35(F), NEC 2011: 690.35(F) ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.17(E), NEC 2017: 690.17(E), NEC 2011: 690.17(4) WARNING! WARNING! WARNING! PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1) LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53, NEC 2011: 690.53 INVERTER #1 SOLAREDGE MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX. RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC- CONVERTER (IF INSTALLED) 480VDC 30.0ADC 19.62ADC PAGE 7 OF 15 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b), NEC 2011: 705.12(D)(7) WARNING ! CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN UTILITY METER & MAIN SERVICE PANEL AC DISCONNECT INVERTER (N) INVERTER (N) AC DSCONNECT (E) UTILITY METER (E) MAIN SERVICE PANEL 24 0 1 N H A T H A W A Y S T 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN EQUIPMENT SPECIFICATION PAGE 13 OF 15 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-15 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN EQUIPMENT SPECIFICATION PAGE 13 OF 15 2401 N Hathaway 08/17/22 VSE Project Number: A0035-0215-221 August 17, 2022 NERD Power 2065 W. Obispo Ave., Suite 102 Gilbert, AZ 85233 REFERENCE: James Minnis Residence: 2401 N Hathaway St, Santa Ana, CA 92705 NERD Power Project: CA-R-185708 Solar Array Installation To Whom It May Concern: Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code: California Building Code, 2019 Edition (2018 IBC) Risk Category: II Design wind speed, Vult: 95 mph (3-sec gust) per ASCE 7-16 Wind exposure category: C Seismic design category: D Connection to Roof Mounting connection: (1) 5/16" lag screw w/ min. 2.5" threaded embedment into framing at max. 48" o.c. along rails (2) rails per row of panels, evenly spaced; panel length perpendicular to the rails not to exceed 69.6 in. Rail cantilever shall not exceed 50% of connection spacing. Conclusions Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array, other live loads will not be present or will be greatly reduced (2019 CBC, Section 1607.13.5). The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Regarding seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 3.1%. Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered. 1635 N. Greenfield Rd., Ste. 112 / Mesa, AZ 85205 / T (480) 648-3514 / www.vectorse.com Page 1 of 7 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 VSE Project Number: A0035-0215-221 James Minnis Residence 8/17/2022 Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor must notify Vector Structural Engineering of Arizona, LLP should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. Connections to existing roof framing must be staggered, except at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. The design of the solar panel racking (mounts, rails, etc.) and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. Vector Structural Engineering of Arizona, LLP 08/17/2022 _______________________________________________________ Michael Gibbons, P.E. Project Engineer Enclosures MEG/cdb 1635 N. Greenfield Rd., Ste. 112 / Mesa, AZ 85205 / T (480) 648-3514 / www.vectorse.com Page 2 of 7 August 17, 2022 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 JOB NO.: A0035-0215-221 SUBJECT: SEISMIC LOADS PROJECT: James Minnis Residence CHECK INCREASE IN OVERALL SEISMIC LOADS 10.2 psf 2.3 psf 14% 10.5 psf 3.1% Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 3.1%. Because the increase is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing structure is permitted to remain unaltered. Addt'l Seismic Weight Estimated Roof Dead Load Solar Dead Load % Roof Covered Equiv. Total Dead Load Page 3 of 7 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 JOB NO.: A0035-0215-221 SUBJECT: WIND PRESSURE PROJECT: James Minnis Residence Label: Note: Calculations per ASCE 7-16 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 95 Notes: Exposure Category: C Risk Category: II Importance Factor, I: ADDITIONAL INPUT & CALCULATIONS: Height of Roof, h [ft]:15 (Approximate) Comp/Cladding Location:Gable Roofs 7° < θ ≤ 20° Enclosure Classification: Zone 1, 2e GCp:2.00 Zone 1, 2e γ a:0.77 Zone 2n, 2r, 3e GCp: 2.91 Zone 2n, 2r, 3e γa:0.77 Zone 3r GCp: 3.48 Zone 3r γa:0.77 γa:0.40 α: 9.5 Table 26.11-1 zg [ft]: 900 Table 26.11-1 Kh: 0.85 Table 26.10-1 Ke: 0.99 Table 26.9-1 Kzt: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 16.6 Equation 26.10-1 γE: 1.50 Section 29.4.4 γC: 0.95 Section 29.4.4 γP: 1.20 Section 29.4.4 p = q h (GC p )(γE )(γa ) p = q h (GC rn ), (GC rn ) = (γ p )(γc )(γ E )(GC rn ) nom Zone 1, 2e, p [psf]: 38.4 psf (1.0 W) Zone 2n, 2r, 3e, p [psf]: 55.9 psf (1.0 W) Zone 3r, p [psf]: 67.0 psf (1.0 W) (a = 5.7 ft) Fig. 29.4-8 WIND PRESSURES: Equation 29.4-7 Solar Panel Array Enclosed Buildings Figure 30.3-2B (negative coeff.) Components and Cladding Wind Calculations Page 4 of 7 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 JOB NO.: A0035-0215-221 SUBJECT: CONNECTION PROJECT: James Minnis Residence Calculate Uplift Forces on Connection Pressure (0.6 Dead -0.6 Wind) (psf) Max Trib. Width1 (ft) Max Trib. Area2 (ft2) Max Uplift Force (lbs) Zone 1, 2e 21.7 4.0 11.6 252 Zone 2n, 2r, 3e 32.2 4.0 11.6 373 Zone 3r 38.8 4.0 11.6 450 Calculate Connection Capacity Lag Screw Size [in]:5/16 Cd:1.6 NDS Table 2.3.2 Embedment3 [in]:2.5 Grade: Nominal Capacity [lbs/in]:205 NDS Table 12.2A Number of Screws:1 Prying Coefficient:1.4 Total Capacity [lbs]:586 Determine Result Maximum Demand [lbs]: 450 Lag Screw Capacity [lbs]: 586 Result: Capacity > Demand, Connection is adequate. Notes 1. 'Max Trib. Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 70". SPF (G = 0.42) 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the embedment length. Page 5 of 7 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 VECTOR STRUCTURAL ENGINEERS JOB NO.: A0035-0215-221 SUBJECT: GRAVITY LOADS PROJECT: James Minnis Residence GRAVITY LOADS Roof Pitch:4.4 :12 ROOF DEAD LOAD (D) Increase due to pitch Material weight [psf] Composite Shingles 1.06 2.0 1/2" Plywood 1.06 1.0 Framing 1.00 3.0 Insulation 1.00 0.0 1/2" Gypsum Clg.1.06 0.0 M, E & Misc 1.00 0.0 Total Existing Roof DL PV Array DL 1.06 2 DL:1.06 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf]20 ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array [psf]0 SNOW LOAD (S):w/ Solar Array Roof Slope [x:12]:4.4 Roof Slope [°]:20 Ground Snow Load, pg [psf]:0 ASCE 7-16, Section 7.2 Terrain Category:C ASCE 7-16, Table 7.3-1 Exposure of Roof:Fully Exposed ASCE 7-16, Table 7.3-1 Exposure Factor, Ce:0.9 ASCE 7-16, Table 7.3-1 Thermal Factor, Ct:1.1 ASCE 7-16, Table 7.3-2 Risk Category:II ASCE 7-16, Table 1.5-1 Importance Factor, Is:1.0 ASCE 7-16, Table 1.5-2 Flat Roof Snow Load, pf [psf]:0 ASCE 7-16, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]:0 ASCE 7-16, Section 7.3.4 Unobstructed Slippery Surface?Yes ASCE 7-16, Section 7.4 Slope Factor Figure:Figure 7-2b ASCE 7-16, Section 7.4 Roof Slope Factor, Cs:0.83 ASCE 7-16, Figure 7.4-1 Sloped Roof Snow Load, ps [psf]:0 ASCE 7-16, Equation 7.4-1 Design Snow Load, S [psf]:0 1.00 0 Design material weight [psf] 2.1 1.1 3.0 0.0 0.0 0.0 6.2 2.4 #VALUE! 2019 CBC, Section 1607.13.5 Existing 0 4.4 20 0 C Fully Exposed 0.9 1.1 II 1.0 0 0 No Figure 7-2b Page 6 of 7 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 JOB NO.: A0035-0215-221 SUBJECT: LOAD COMPARISON PROJECT: James Minnis Residence Summary of Loads Existing With PV Array D [psf]6 9 Lr [psf]20 0 S [psf]0 0 Maximum Gravity Loads: Existing With PV Array (D + Lr) / Cd [psf] 21 10 ASCE 7-16, Section 2.4.1 (D + S) / Cd [psf] 7 10 ASCE 7-16, Section 2.4.1 Maximum Gravity Load [psf]: 21 10 Ratio Proposed Loading to Current Loading:46% OK The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is permitted to remain unaltered. (Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr) Page 7 of 7 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 Project: Location: Calc. by: Date: STRUCTURAL CERTIFICATION LETTER To: Project: To Whom It May Concern: DESIGN CRITERIA: DESCRIPTION OF EXISTING ROOF STRUCTURE: ROOF 1 to 3- 2x4 Rafters @ 24" o.c. with a maximum unsupported horizontal span of 10'-0" and a slope of 20 degrees CONCLUSIONS: Max PV mount spacing- Landscape config: 48", Portrait config: 48", Pattern: Staggered (ROOF 1 to 3) Attachment to Framing: 1 - 5/16" Lag Screw(s) w/ 2.5" min embed @ above spacing (ALL ROOFS) Sincerely, Paymon Eskandanian, SE, PE Laguna Consulting Engineers/ Laguna Pacific Group This review relies on the roof’s structural system having been originally designed and constructed in accordance with the building code requirements and having been maintained to be in good condition. The design of racking, rails, panels and all other hardware is outside of the scope of this report. All components and waterproofing shall be installed per manufacturer specifications. Laguna Pacific Group assumes no responsibility for improper installation of solar PV panels, racking, or waterproofing. Please do not hesitate to contact me should you have any questions or comments. 2401 N Hathaway St Santa Ana, CA 92705 Minnis Residence Santa Ana, CA PE 11/12/202128202 CABOT ROAD, SUITE 300 LAGUNA NIGUEL, CA 92677 November 12, 2021 Enphase Energy 47281 Bayside Parkway Fremont, CA 94538 Minnis Residence A structural evaluation of the existing roof structure to support a new roof-mounted Photovoltaic (PV) system and its attachment to the underlying structure was performed based on the Design Criteria noted below. The structural review only applies to the section of the roof that is directly supporting the solar PV system and its supporting elements. Contractor shall verify the framing sizes, spacings, and spans noted in the stamped plans and accompanying calculations and notify the Engineer of Record of any discrepancies prior to starting construction. ROOF 1 to 3- Adequate to support the imposed loading - No structural upgrades required Roof Dead Load(s): 9 psf, Comp Shingles (ROOF 1 to 3) Applicable Codes: 2019 California Building Code, ASCE 7-16 Risk/ Occupancy Category: II Roof Live Load(s): 20 psf, 0 psf Under PV Ground Snow Load: 0 psf Basic Wind Speed: 110 mph, Exposure Category: C LAGUNA CONSULTING ENGINEERS LAGUNA PACIFIC GROUP, INC. Page 1 12/21 2401 N Hathaway 08/17/22 Project: Location: Calc. by: Date: GRAVITY LOADS (ROOF 1 to 3) 3 psf Note: PV System Weight Provided by Client/ Manuf. ASCE Ch-3 4 psf 4 psf 0.73 psf 0 psf 0.27 psf 9 psf ASCE Ch-4 20 psf ≤ 200 sq.ft 1 5/12 (20 Deg.) 1.00 20 psf Note: Live Load Under PV Arrays = 0 PSF. ASCE Ch-7 0 psf 1 Table 7.3-1 1 Table 7.3-1 1 N/A psf N/A psf 0.0 psf Eqn 7.3-1 5/12 (20 Deg.) 1.00 0.0 psf Eqn 7.4-1 Minnis Residence Santa Ana, CA PE 28202 CABOT ROAD, SUITE 300 LAGUNA NIGUEL, CA 92677 11/12/2021 ITEM VALUE Ground Snow Load, pg = VALUE Slope Reduction Factor, R2 = ROOF LIVE LOAD, LLROOF = L0 . R1 . R2 = 3. ROOF LIVE LOAD ITEM Roof Live Load, L0 = Tributary Area Supported By Member, AT = Tributary Area Reduction Factor, R1 = Roof Slope = 1. NEW PV SYSTEM DEAD LOAD ITEM LOAD (N) PV SYSTEM DEAD LOAD, DLPV-N = 2. ROOF DEAD LOAD ITEM LOAD Comp Shingles Plywood & Skip Sheathing 2x4 Rafters @ 24" O.C. Vaulted Ceiling Miscellaneous ROOF DEAD LOAD, DLROOF = Slope Factor, Cs = ROOF SNOW LOAD, ps = Cs . pf = Minimum Flat Roof Snow Load (AHJ), pf_min_AHJ = Flat Roof Snow Load, pf = 0.7CeCtIspg + pf_sur ; pf ≥ pf_min_AHJ –› pf = Roof Slope = Surface Type = All Other Surfaces Exposure Factor (Fully Exposed), Ce = Thermal Factor (Cold Roof), Ct = Snow Importance Factor, Is = Minimum Low-Slope Roof Snow Load, pLS_min = 4. ROOF SNOW LOAD LAGUNA CONSULTING ENGINEERS LAGUNA PACIFIC GROUP, INC. Page 2 2401 N Hathaway 08/17/22 Project: Location: Calc. by: Date: WIND LOADS (ROOF 1 to 3) Wind loads on standoffs and their attachment to the underlying structure are determined as per the requirements for rooftop solar panels parallel to the roof surface (ASCE 7-16, Section 29.4.4). Risk Category =II Basic Wind Speed, V (ULT) =110 mph Wind Directionality Factor, K d = 0.85 Table 26.6-1 Exposure Category =C Topographic Factor, Kz t = 1.0 Table 26.8-1 Ground Elevation Factor, K e = 1.0 Table 26.9-1 Mean Roof Height, h =12 ft (Max) Velocity Pressure Exposure Coefficient, K z = 0.85 Table 26.10-1 Velocity Pressure, qh = 0.00256KzKztKdKeV 2 =22.35 psf (ULT)Eq. 26.10-1 qₕ_ASD = 0.6 x qₕ_ULT =13.41 psf Roof Type =Gabled Roof Slope =20 Degrees gE =1.0 29.4-4 Effective Wind Area, Aeff = See Table Below 26.2 Design Wind Pressures (ASD), pUPLIFT (ASD) = qh (ASD) . (GCp). gE . ga ; pASD_MIN = 10 psf Eq. 29.4-7 Standoff Net Uplift Forces, PUplift (ASD) (lbs) = pWIND ASD x Atrib - 0.6PDL (See Table Below) DOWNWARD ALL ZONE 1 (Interior) ZONE 2 (Edge) ZONE 3 (Corner) ZONE 1 (Interior) ZONE 2 (Edge) ZONE 3 (Corner)ALL ZONES gA 0.78 0.78 0.80 0.80 0.80 0.80 0.80 -2.00 -2.91 -3.60 -2.00 -3.00 -3.60 0.57 -20.8 -30.3 -38.6 -21.5 -32.2 -38.6 10.0 48.00 48.00 32.00 48.00 48.00 32.00 48.00 2.88 2.88 2.88 1.71 1.71 1.71 2.88 11.52 11.52 7.68 6.83 6.83 4.56 11.52 -219 -328 -283 -134 -208 -168 136 ROOF ATTACHMENT CHECKS Max Standoff Uplift (ASD) = 328 lbs Standoff Allowable Uplift = 450 lbs (Per Manuf.) Standoff Demand/Capacity Ratio, DCR = 73%< 100%, Therefore O.K. Fastener Size and Type = 5/16” No. of Fasteners per Standoff, N =1 Min Fastener Embed Into Framing, T =2.5 in Fastener Allowable Pullout Per Inch, W = 246 lb/in Additional Factor of Safety, F.S =1.5 656 lbs Fastener Demand/Capacity Ratio, DCR = 50% < 100%, Therefore O.K. Lag Screw(s) Panel Configuration LANDSCAPE UPLIFT Standoff Net Uplift Forces, PUplift (ASD) (lbs) Trib. Area, ATrib (ft 2) PORTRAIT ZONE GCp Design Wind Pressures (ASD), pUPLIFT (ASD) (psf) Standoff X-Spacing (in) Trib. Width (ft) PRESSURES Minnis Residence Santa Ana, CA PE 28202 CABOT ROAD, SUITE 300 LAGUNA NIGUEL, CA 92677 11/12/2021 Fastener Group Allowable Pullout Capacity, TALL = (N x W x T x LDF = 1.6) / (F.S.) = LAGUNA CONSULTING ENGINEERS LAGUNA PACIFIC GROUP, INC. Page 3 2401 N Hathaway 08/17/22 Project: Location: Calc. by: Date: MEMBER CHECKS (ROOF 1 to 3) PASS 1. (E) WOOD ROOF CONSTRUCTION: ROOF SLOPE = 20° FRAMING TYPE = Rafters WOOD SPECIES & GRADE = DF #2 RAFTER OR TRUSS TOP CHORD SIZE = 2x4 (S =3.06 in^3 ; I = 5.35 in^4) RAFTER OR TRUSS SPACING = 24" o.c. MEMBER HORIZONTAL SPAN, L = 10'-0"10 2. MEMBER LOADING: GOVERNING LOAD CASE = TOTAL LOAD, WTL = 3. BENDING CHECKS: REFERENCE DESIGN BENDING STRESS, F b = 900 psi LOAD DURATION FACTOR, Cd =0.90 SIZE FACTOR, CF =1.50 REPETITIVE MEMBER FACTOR, Cr =1.15 ALLOWABLE BENDING STRESS, F' b = Fb x Cd x Cf x Cr =1,397 psi MEMBER BENDING STRESS, f b = Mmax / S =1,251 psi BENDING DEMAND-CAPACITY RATIO = f b / F'b =90% < 100%BENDING O.K. 4. SHEAR CHECKS: REFERENCE DESIGN SHEAR STRESS, F v = 180 psi LOAD DURATION FACTOR, Cd =0.90 ALLOWABLE SHEAR STRESS, F' v = Fv x Cd =162 psi MAX SHEAR, Vmax = WTL.L / 2 =128 lbs MEMBER AREA, A =5.25 in2 MEMBER SHEAR STRESS, fv = Vmax / A =24.3 psi SHEAR DEMAND-CAPACITY RATIO = fv / F' v = 15% < 100%SHEAR O.K. 5. DEFLECTION CHECKS: ALLOWABLE DEFLECTION (TOTAL LOAD), D ALL-TL = (L/120) E = = 1.000 in SPAN TYPE = MAX DEFLECTION (TOTAL LOAD), D MAX-TL = 5 WL^4/384EI = 0.670 in (L/179) DMAX-TL < DALL-LL TOTAL LOAD DEFLECTION O.K. * RLL = 0 PSF UNDER PV 1,600,000 psi Simple Span DL + PV 26 plf ROOF SNOW LOAD 0.0 0.0 0.0 ROOF DEAD LOAD ROOF LIVE LOAD*0.0 0.0 0.0 9.0 9.6 19.2 PV DEAD LOAD 3.0 3.2 6.4 LOAD TYPE UNIFORM LOAD (PSF) U.L. PROJECTION OVER HORIZ. SPAN (PSF) MEMBER DESIGN LOAD (PLF) PE 28202 CABOT ROAD, SUITE 300 LAGUNA NIGUEL, CA 92677 11/12/2021 Minnis Residence Santa Ana, CA LAGUNA CONSULTING ENGINEERS LAGUNA PACIFIC GROUP, INC. Page 4 2401 N Hathaway 08/17/22 Project: Location: Calc. by: Date: LATERAL (SEISMIC) LOAD CHECKS DUE TO ADDITION OF (N) PHOTOVOLTAIC SYSTEM PER 2018 IEBC | 2019 CEBC SECTION 503.4 Existing Roof Seismic Weight: Existing Seismic Weight @ Roof Level, WE = New PV System Seismic Weight: Seismic Weight of New PV System, WPV = 2.7% < 10%, Therefore O.K. Minnis Residence Santa Ana, CA PE 11/12/2021 45,993 LBS WEIGHT (LBS) 2,179 5,230 11,872 26,712 * Note: Wall Height, H= 8'-0" Therefore, the exception provided under IEBC / CEBC Section 503.4 applies since the (N) load due to the addition of PV System does not exceed the 10% threshold of the existing seismic weight. % Increase in Lateral (Seismic) Weight @ Roof Level Due to PV System Addition, %-Increase = WPV / WE = 1,235 LBS ELEMENT UNIT WEIGHT (PSF) AREA (SQ.FT) WEIGHT (LBS) PV System 3 411.8 1,235 AREA (SQ.FT) UNIT WEIGHT (PSF) 4365 29689 Interior Walls* Exterior Walls* 29684Ceiling 436 Roof DL (7/8" Stucco) 12 28202 CABOT ROAD, SUITE 300 LAGUNA NIGUEL, CA 92677 ELEMENT LAGUNA CONSULTING ENGINEERS LAGUNA PACIFIC GROUP, INC. Page 5 2401 N Hathaway 08/17/22 MSPACD INV UM JB BAT BI PLP REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 PROJECT ID J A M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV STRING LAYOUT 1 STRING LAYOUT PV-3 SCALE: 1/8" = 1'-0" PAGE 3 OF 18 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 21 LONGI SOLAR LR4-60HPB 355M 355W MODULES INVERTER 01 SOLAREDGE TECHNOLOGY: SE6000H-US (240V) INVERTER INTEGRATEDRAPID SHUTDOWN OPTIMIZER 21 SOLAREDGE POWER OPTIMIZERS P-401 AC DISCONNECT 1 AC DISCONNECT EATON#DG223URB 100A, 2P,600VAC NEMA 3R BATTERY 1 LG CHEM RESU16H BATTERY PROTECTED LOAD PANEL 1 PROTECTED LOAD PANEL 100A BACKUP INTERFACE 1 BACKUP INTERFACE BI-NUSGN-01 ATTACHMENT 46 CHIKOUSA COMPOSITION L-FOOT ATTACHMENTS RAILS 6 CHIKOUSA 7 RAILS 134" RAILS 6 CHIKOUSA 7 RAILS 166" RAIL SPLICE 4 SPLICE KIT MID CLAMPS 34 MID CLAMPS END CLAMPS 16 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 4 GROUNDING LUG (E ) B A C K O F R E S I D E N C E (E ) F R O N T O F R E S I D E N C E N H A T H A W A Y S T STRING 1 STRING 2 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 MSPACD INV UM JB REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 PROJECT ID J A M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN STRING LAYOUT 1 STRING LAYOUT PV-3 SCALE: 1/8" = 1'-0" PAGE 3 OF 15 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 21 LONGI SOLAR LR4-60HPB 355M 355W MODULES INVERTER 01 SOLAREDGE TECHNOLOGY: SE6000H-US (240V) INVERTER INTEGRATEDRAPID SHUTDOWN OPTIMIZER 21 SOLAREDGE POWER OPTIMIZERS P-401 AC DISCONNECT 1 AC DISCONNECT EATON#DG221URB 60A, 2P,600VAC NEMA 3R ATTACHMENT 74 CHIKOUSA COMPOSITION L-FOOT ATTACHMENTS RAILS 14 CHIKOUSA 7 RAILS 134" RAILS 3 CHIKOUSA 7 RAILS 166" RAIL SPLICE 12 SPLICE KIT MID CLAMPS 30 MID CLAMPS END CLAMPS 24 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 6 GROUNDING LUG (E ) B A C K O F R E S I D E N C E (E ) F R O N T O F R E S I D E N C E N H A T H A W A Y S T STRING 2 STRING 1 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # LONGI SOLAR LR4-60HPB 355M 355 (355W)MODULES VMP 34.6 IMP 10.27 VOC 40.6 ISC 11.25 MODULE DIMENSION 69.09"L x 40.87"W x 1.50"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE TECHNOLOGY SE6000H-US NOMINAL AC POWER 6.0KW NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 25A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2° AMBIENT TEMP (HIGH TEMP 2%)31° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 53° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%/°C EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 17.58A 1.25 X 1.25 X MODULE ISC DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 30.72ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (17.58A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c)+22° EXPECTED WIRE TEMP (In Celsius)31 +22 = 53 TEMP. CORRECTION PER TABLE (310.16)0.76 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.75A 1.25 X OPTIMIZER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 24.32ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO BACKUP INTERFACE: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1 CIRCUIT CONDUCTOR SIZE 8AWG CIRCUIT CONDUCTOR AMPACITY 55A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 31.25A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 52.80A TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity PAGE 6 OF 18 NOTES :- THE DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY IS LESS THAN 23 mm (7/8 IN.) AS PER TABLE 310.15(B)(2)(a) OR TABLE 310.15(B)(2)(b) AC CONDUCTOR AMPACITY CALCULATIONS: FROM BACKUP INTERFACE TO MAIN SERVICE PANEL: EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1 CIRCUIT CONDUCTOR SIZE 2 CIRCUIT CONDUCTOR AMPACITY 130A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 31.25A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 124.80ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # LONGI SOLAR LR4-60HPB 355M 355 (355W)MODULES VMP 34.6 IMP 10.27 VOC 40.6 ISC 11.25 MODULE DIMENSION 69.09"L x 40.87"W x 1.50"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE TECHNOLOGY SE6000H-US NOMINAL AC POWER 6.0KW NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 25A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2° AMBIENT TEMP (HIGH TEMP 2%)31° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 53° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%/°C EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 17.58A 1.25 X 1.25 X MODULE ISC DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 30.72ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (17.58A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c)+22° EXPECTED WIRE TEMP (In Celsius)31 +22 = 53 TEMP. CORRECTION PER TABLE (310.16)0.76 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.75A 1.25 X OPTIMIZER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 24.32ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO MAIN SERVICE PANEL: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 31.25A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 38.40A TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity PAGE 6 OF 15 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-18 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 18 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV OPTIMIZER CHART 1-10 1 2 3 4 11-20 21-30 31-40 41-50 51-60 5 6 7 8 9 10 OPTIMIZER CHART PAGE 8 OF 18 N H A T H A W A Y S T 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN OPTIMIZER CHART 1-10 1 2 3 4 11-20 21-30 31-40 41-50 51-60 5 6 7 8 9 10 OPTIMIZER CHART PAGE 8 OF 15 N H A T H A W A Y S T 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 9 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN EQUIPMENT SPECIFICATION PAGE 9 OF 15 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 10 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN EQUIPMENT SPECIFICATION PAGE 10 OF 15 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 11 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN EQUIPMENT SPECIFICATION PAGE 11 OF 15 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 12 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-15 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 15 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-16 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 16 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-17 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 17 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 6'-9" 11'-7" 1'-6" 1 1 ' - 5 " 5' - 9 " 1 ' - 6 " MSPACD INV UM JB 7'-0" 13'-10"13'-6" 2' - 1 0 " 5' - 9 " 3' - 5 " BAT BI PLP REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 PROJECT ID J A M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV ROOF PLAN & MODULES ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 20°180° 2"x4"24" o.c. #2 20°270° 2"x4"24" o.c. #3 20°180° 2"x4"24" o.c. LEGEND - JUNCTION BOX MSP - MAIN SERVICE PANEL - VENTS, DISH (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT - UTILITY METER SCALE: 1/8" = 1'-0" - SOLAREDGE OPTIMIZER MODULE TYPE, DIMENSIONS & WEIGHT ACD - AC DISCONNECT - INVERTER 1 PV-2 NUMBER OF MODULES = 21 MODULES MODULE TYPE = LONGI SOLAR LR4-60HPB 355M 355W MODULES MODULE WEIGHT = 42.99 LBS / 19.5 KG. COMPONENT WEIGHT: 1.5 LBS. PER MODULE TOTAL DEAD LOAD: 934.29 LBS. POINT LOAD PER STANDOFF.: 934.29 LBS / 46 STANDOFF = 20.31 LBS MODULE DIMENSIONS = 69.09"x 40.87" = 19.61 SF UNIT WEIGHT OF ARRAY = 2.27 PSF UM JB INV ARRAY AREA WITH TOTAL ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 3 58.83 251.79 23.36 #2 14 274.53 1006.68 27.27 #3 4 78.44 341.78 22.95 ROOF PLAN & MODULES PAGE 2 OF 18 ARRAY AREA WITH WHOLE ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1-3 21 411.79 2968.52 13.87 LONGI SOLAR LR4-60HPB 355M 355W MODULES 40.87" 69 . 0 9 " - GAS METERGAS 3/4" EMT CONDUIT RUN ON ROOF (N) CHIKO ASPHALT RACKING SYSTEM (46) CHIKOUSA COOMPOSITION L-FOOT ATTACHMENTS @48"O.C. (E ) B A C K O F R E S I D E N C E (E ) F R O N T O F R E S I D E N C E N H A T H A W A Y S T (N) MAIN SERVICE PANEL, 225A RATED, 240V, (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT (E) UTILITY METER ROOF #03 (4) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF ACCESS POINT ROOF #01 (3) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #02 (14) LONGI SOLAR LR4-60HPB 355M 355W MODULES 18" FIRE SETBACK 18" FIRE SETBACK 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 18" FIRE SETBACK 18" FIRE SETBACK 36 " F I R E S E T B A C K (N) JUNCTION BOX (E) CHIMNEY (21) SOLAREDGE POWER OPTIMIZER P-401 ROOF #3 TILT - 20° AZIM. - 180° ROOF #2 TILT - 20° AZIM. - 270° ROOF #1 TILT - 20° AZIM. - 180° (N) BATTERY BAT - BATTERY (N) BACKUP INTERFACE (N) PROTECTED LOAD PANEL Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Electrical, mechanical, architectural, and all other nonstructural aspects of the design are by others. VSE Project#: A0035-0215-221 August 17, 2022 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV ATTACHMENT DETAIL PAGE 4 OF 18 SCALE: NTS 2 PV-4 ATTACHMENT DETAIL SCALE: NTS 1 PV-4 PV MODULE SEE (2/PV-3) FOR ENLARGED VIEW (E) SINGLE LAYER OF COMP SHINGLE PV MODULES CHIKOUSA 7 RAILS FLASHING COMPOSITION L-FOOT ATTACHMENT (E) SINGLE LAYER OF COMP SHINGLE GROUNDING & END/MID CLAMP CHIKO ASPHALT RACKING SYSTEM 2"x4" RAFTERS @ 24" O.C. 5/16" x 3 1/2" SS LAG BOLT INTO RAFTER(S) 2 1/2" MIN. PENETRATION SEALED W/ GEOCEL. CHIKOUSA CHANNEL NUT 2"X4" RAFT E R S @ 24"O.C. 6" ATTACHMENT DETAIL (enlarged view) Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Electrical, mechanical, architectural, and all other nonstructural aspects of the design are by others. VSE Project#: A0035-0215-221 August 17, 2022 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 13 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A01/20/2022 REV B03/11/2022 REV C03/14/2022 REV EQUIPMENT SPECIFICATION PAGE 14 OF 18 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 7'-4" 12'-6" 1'-6" 1 0 ' - 4 " 6' - 1 1 " 1 ' - 6 " MSPACD INV UM JB 7'-0" 17'-5"9'-11" 2' - 1 0 " 3' - 5 " 5' - 9 " REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 PROJECT ID J A M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN ROOF PLAN & MODULES ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 20°180° 2"x4"24" o.c. #2 20°270° 2"x4"24" o.c. #3 20°180° 2"x4"24" o.c. LEGEND - JUNCTION BOX MSP - MAIN SERVICE PANEL - VENTS, DISH (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT - UTILITY METER SCALE: 1/8" = 1'-0" - SOLAREDGE OPTIMIZER MODULE TYPE, DIMENSIONS & WEIGHT ACD - AC DISCONNECT - INVERTER 1 PV-2 NUMBER OF MODULES = 21 MODULES MODULE TYPE = LONGI SOLAR LR4-60HPB 355M 355W MODULES MODULE WEIGHT = 42.99 LBS / 19.5 KG. COMPONENT WEIGHT: 1.5 LBS. PER MODULE TOTAL DEAD LOAD: 934.29 LBS. POINT LOAD PER STANDOFF.: 934.29 LBS / 74 STANDOFF = 12.63 LBS MODULE DIMENSIONS = 69.09"x 40.87" = 19.61 SF UNIT WEIGHT OF ARRAY = 2.27 PSF UM JB INV ARRAY AREA WITH TOTAL ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 3 58.83 251.79 23.36 #2 15 294.14 1006.68 29.22 #3 3 58.83 341.78 17.21 ROOF PLAN & MODULES PAGE 2 OF 15 ARRAY AREA WITH WHOLE ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1-3 21 411.79 2968.52 13.87 LONGI SOLAR LR4-60HPB 355M 355W MODULES 40.87" 69 . 0 9 " - GAS METERGAS 3/4" EMT CONDUIT RUN ON ROOF (N) CHIKO ASPHALT RACKING SYSTEM (74) CHIKOUSA COOMPOSITION L-FOOT ATTACHMENTS @48"O.C. (E ) B A C K O F R E S I D E N C E (E ) F R O N T O F R E S I D E N C E N H A T H A W A Y S T (N) MAIN SERVICE PANEL, 225A RATED, 240V, (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT (E) UTILITY METER ROOF #03 (3) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF ACCESS POINT ROOF #01 (3) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #02 (15) LONGI SOLAR LR4-60HPB 355M 355W MODULES 18" FIRE SETBACK 18" FIRE SETBACK 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T B A C K 18" FIRE SETBACK 18" FIRE SETBACK 36 " F I R E S E T B A C K (N) JUNCTION BOX (E) CHIMNEY (21) SOLAREDGE POWER OPTIMIZER P-401 ROOF #3 TILT - 20° AZIM. - 180° ROOF #2 TILT - 20° AZIM. - 270° ROOF #1 TILT - 20° AZIM. - 180° 12/21 STAMPED FOR EXISTING ROOF AND ATTCHMENT ONLY 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN ATTACHMENT DETAIL PAGE 4 OF 15 SCALE: NTS 2 PV-4 ATTACHMENT DETAIL SCALE: NTS 1 PV-4 PV MODULE SEE (2/PV-3) FOR ENLARGED VIEW (E) SINGLE LAYER OF COMP SHINGLE PV MODULES CHIKOUSA 7 RAILS FLASHING COMPOSITION L-FOOT ATTACHMENT (E) SINGLE LAYER OF COMP SHINGLE GROUNDING & END/MID CLAMP CHIKO ASPHALT RACKING SYSTEM 2"x4" RAFTERS @ 24" O.C. 5/16" x 3 1/2" SS LAG BOLT INTO RAFTER(S) 2 1/2" MIN. PENETRATION SEALED W/ GEOCEL. CHIKOUSA CHANNEL NUT 2"X4" RAFT E R S @ 24"O.C. 6" ATTACHMENT DETAIL (enlarged view) 12/21 STAMPED FOR EXISTING ROOF AND ATTCHMENT ONLY 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN EQUIPMENT SPECIFICATION PAGE 12 OF 15 2401 N Hathaway 08/17/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 PROJECT ID JA M E S M I N N I S 24 0 1 N H A T H A W A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH10/23/2021 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH KABILAN SELVARANGAN EQUIPMENT SPECIFICATION PAGE 13 OF 15 2401 N Hathaway 08/17/22 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST Nerd Power LLC 1019100 Heather Stork 602-491-9326 caprocessing@nerdpower.energy 2401 N Hathaway St, Santa Ana, CA 92705 12/13/2021 2401 N Hathaway 08/17/22 03/09/2023 RE: Structural Certification for Installation of Residential Solar JAMES MINNIS:2401 N HATHAWAY ST, SANTA ANA, CA 92705 Attn: To Whom It May Concern Design Criteria Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 95 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E.Signed 3/9/2023 EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition shingle roofing over roof plywood supported by 2X4 Rafters at 24 inches. The slope of the roof was approximated to be 20 degrees and the allowable maximum rafter span is 6 feet between supports. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 Structural Letter for PV Installation Date: 03/09/2023 Job Address: 2401 N HATHAWAY ST SANTA ANA, CA 92705 Job Name: JAMES MINNIS Job Number: 230309JM Scope of Work Table of Content Sheet 1 Cover 2 Attachment Uplift checks 3 Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2022 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 95 mph Exposure C References NDS for Wood Construction Sincerely, Signed 3/9/2023 Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. projects@evengineersnet.com http://www.evengineersnet.com 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 Wind Load Cont. 95 mph ASCE 7-16 Figure 26.5-1B C 1.0 ASCE 7-16 Sec 26.8.2 0.85 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 0.99 ASCE 7-16 Table 26.9-1 16.59 psf 20.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1) Zone(2r) Zone(2e)Zone(3) Fig. 30-3-2 GCp=-2.1 -2.6 -2.7 -2.7 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-41.80 -51.75 -53.74 -53.74 GCp=0.3 Figure 30.3-2 P=qh(GCp)(γE)(γa)=4.48 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing= 4 ft 5/16" Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity= 760 lbs Zone Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1) 4 11.0 221.7 82.3 Zone(2r) 4 11.0 271.0 82.3 Zone(2e) 4 11.0 280.9 82.3 Zone(3) 4 11.0 280.9 82.3 Conservative Max= 280.9 < 760 CONNECTION IS OK 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration Risk Category = KZ = Kd = Ke = projects@evengineersnet.com http://www.evengineersnet.com 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg= 0 psf Ct = 1.1 Ce = 0.9 Is = 1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1) 0 plf Max Length, L = 6.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT = 24 in Dr = 10 psf 20 plf PvDL = 3 psf 12 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL= 36 plf Mdown= 162 lb-ft Mallowable = Sx x Fb' (wind)= 456 lb-ft > 162 lb-ft OK Load Case: DL+S Ps+ Ppvcos(θ)+PDL= 32 plf Mdown= 144 lb-ft Mallowable = Sx x Fb' (wind)= 456 lb-ft > 144 lb-ft OK Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL= 37.4 plf Max Moment, Mu= 168 lb-ft Mallowable = Sx x Fb' (wind)= 634 lb-ft > 168 lb-ft OK Pv max Shear= 82.3 lbs Shear, Vu=wL/2+Pv Point Load = 178 lbs Max Shear, Vu=wL/2+Pv Point Load = 178 lb Member Capacity DF-L No.2 2X4 CL CF Ci Cr KF φ λ Fb = 900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin = 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 3.5 in Width, b = 1.5 in Cross-Sectonal Area, A = 5.25 in2 Moment of Inertia, Ixx = 5.35938 in4 Section Modulus, Sxx = 3.0625 in Allowable Moment, M all = Fb'Sxx = 396.2 lb-ft DCR=Mu/Mall = 0.36 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A = 630.0 lb DCR=Vu/Vall = 0.28 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 14% Dpv and Racking 3 psf Average Total Dead Load 10.4 psf Increase in Dead Load 1.7%OK Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - JAMES MINNIS. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com 2401 N Hathaway - 20177169 (Battery Back-Up)06/12/23 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 2401 N Hathaway 08/17/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 2401 N Hathaway 08/17/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan                                                          2401 N Hathaway 08/17/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram                                                                                                                                                                                                                                                  2401 N Hathaway 08/17/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) 2401 N Hathaway 08/17/22