Loading...
HomeMy WebLinkAbout2880 N Main St - PlanN EXTERIOR LIGHTING PROGRAM VICINITY MAP âBank of America CALIFORNIA ATM LIGHTING REQUIREMENTS: CALIFORNIA FINANCE CODE SECTIONS 13000-13070 www.gmr1.com Office: (972) 771-6038 1629 Smirl Drive, Suite 200, Heath, Texas 75032 2880 N Main St Santa Ana, CA 92705 DRAWING INDEX: - LU-1 LU-2 LU-3 LU-4 E-0 E-1 E-2 E-3 COVER SHEET GENERAL NOTES LUMINAIRE SCHEDULE FULL SITE PHOTOMETRICS PLAN AT GRADE LANDSCAPING PLAN GENERAL NOTES & SCHEDULES SITE PLAN - LIGHTING TITLE 24 DOCUMENTS TITLE 24 DOCUMENTS CAW-432 2880 N. Main St. Santa Ana, CA v3 200605 SCOPE OF WORK: APN NUMBER: 002-222-01 11 7 2 1 1 REPLACE EXISTING FIXTURE REMOVE AND PATCH ADD NEW POLE AND FIXTURE ADD NEW FIXTURE OUT OF SCOPE - - - - - PLANS DESIGNED TO CALIFORNIA LEGISLATIVE 13040 & 13041 ATM LIGHTING STANDARDS. DUE TO CRITERIA OF ATM STANDARDS, LOCAL JURISDICTION LIGHTING CODE MAY NOT BE MET. 12/7/2020Kathy Kang Tung Le 12/7/2020 x x Police - William McGovern 12/7/2020 Final inspection required. Public works ok per Jason Kwak. 12/7/2020 BLDG# 101104398 / ELEC# 20171818 2020-160821 12/07/20 N EXTERIOR LIGHTING PROGRAM VICINITY MAP âBank of America CALIFORNIA ATM LIGHTING REQUIREMENTS: CALIFORNIA FINANCE CODE SECTIONS 13000-13070 www.gmr1.com Office: (972) 771-6038 1629 Smirl Drive, Suite 200, Heath, Texas 75032 2880 N Main St Santa Ana, CA 92705 DRAWING INDEX: - LU-1 LU-2 LU-3 LU-4 E-0 E-1 E-2 E-3 COVER SHEET GENERAL NOTES LUMINAIRE SCHEDULE FULL SITE PHOTOMETRICS PLAN AT GRADE LANDSCAPING PLAN GENERAL NOTES & SCHEDULES SITE PLAN - LIGHTING TITLE 24 DOCUMENTS TITLE 24 DOCUMENTS CAW-432 2880 N. Main St. Santa Ana, CA v3 200605 SCOPE OF WORK: APN NUMBER: 002-222-01 11 7 2 1 1 REPLACE EXISTING FIXTURE REMOVE AND PATCH ADD NEW POLE AND FIXTURE ADD NEW FIXTURE OUT OF SCOPE - - - - - PLANS DESIGNED TO CALIFORNIA LEGISLATIVE 13040 & 13041 ATM LIGHTING STANDARDS. DUE TO CRITERIA OF ATM STANDARDS, LOCAL JURISDICTION LIGHTING CODE MAY NOT BE MET. 12/7/2020Kathy Kang Tung Le 12/7/2020 x x Police - William McGovern 12/7/2020 Final inspection required. Public works ok per Jason Kwak. 12/7/2020 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 âBank of America E-0 GENERAL NOTES & SCHEDULES Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CAW-432 · · Main Place Op CAW-432 2880 N. Main St. Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE Job No.Date 20099-CAW-43207/13/2020 LUMINAIRE SCHEDULE **SEE FIXTURE CLARIFICATION NOTE #9 (NP) = NEW POLE (CBO) CONTROLLED BY OTHERS SYMBOL QTY LABEL FIXTURE ARRANGEMENT TOTAL FIXTURE COUNT NEW POLE COUNT FIXTURE TYPE / MOUNTING / MANUFACTURER BUG RATING MOUNTING HEIGHT MOUNTING ACCESSORIES 3 BO1 SINGLE (BO) CPY250-A-DM-F-20W-UL-WH-40K / CANOPY MOUNT / CREE MATCH EXISTING 1 BQ1 SINGLE (BQ) CPY250-B-DM-F-C-UL-WH-40K / CANOPY MOUNT / CREE MATCH EXISTING 1 SH1 SINGLE (SH) SEC-EDG-4M-WM-02-E-UL-BZ-350-40K / WALL MOUNT / CREE MATCH EXISTING 1 SH2 SINGLE (SH) SEC-EDG-4M-WM-02-E-UL-BZ-350-40K / WALL MOUNT / CREE 8' AFG 1 UU1 DOUBLE (2@180°) AME-2-L-T4-144LC-5-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE MATCH EXISTING 2 UU2 (NEW POLE) SINGLE AME-2-L-T2-72LC-5-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE 14' AFG 1 UU3 SINGLE AME-2-L-T4-72LC-3-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE MATCH EXISTING 1 UU4 SINGLE AME-2-L-T5-144LC-5-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE MATCH EXISTING 1 UU5 DOUBLE (2@180°) AME-2-L-T4-72LC-3-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE MATCH EXISTING 2 RC1 SINGLE EXISTING FLOOD FIXTURE - 4 RE1 SINGLE EXISTING CANOPY FIXTURE - 1 RI1 SINGLE EXISTING WALL FIXTURE - 1 YA1 SINGLE EXISTING POLE FIXTURE - ** CONTRACTOR TO VERIFY MOUNTING ACCESSORIES BEFORE ORDERING** 3 1 1 1 2 2 1 1 2 2 4 1 1 - - - - - 2 - - - - - - - B1-U0-G1 B2-U0-G1 B1-U0-G1 B1-U0-G1 B3-U0-G4 B3-U0-G3 B2-U0-G2 B4-U0-G2 B2-U0-G2 - - - - XA-BXCC9001 XA-BXCC9001 - - - - - - - - - - - TOTAL FIXTURE WATTAGE EXISTING FIXTURE WATTAGE BEING REMOVED/REPLACED 77 400 - 100 - 100 - 100 - - 115 - 77 400 229 400 20 100 31 100 25 100 25 - 229 400 2020-160821 12/07/20 2020-160821 12/07/20 âBank of America Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CAW-432 E-2 TITLE 24 DOCUMENTS Main Place Op CAW-432 2880 N. Main St. Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE Job No.Date 20099-CAW-43207/13/2020 2020-160821 12/07/20 âBank of America Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CAW-432 E-3 TITLE 24 DOCUMENTS Main Place Op CAW-432 2880 N. Main St. Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE Job No.Date 20099-CAW-43207/13/2020 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 >!!#.&&$!(),%,.&&!!!!5!!#(,($!+&*%+*'+ HF2!!VUST]UXS(O[QQ(OYW >!!#.&&$!*-)%'()*!!!!5!!#.&&$!./&%-+&-5MXMPM2!!```(O[QQ(OYW)OMXMPM P]n."BYl];"T11"08/03/2017 B[PQ[UXS!<XRY[WM]UYX CpYehd];"ANW250-@-BK-B-?-SJ-QT" 2;@!=CLFCM!%!?CLMFJI!1 ANW250€"JCB"AYfghq/Qg^^al"JmeafYaj]" 5CK,/* 4 C[YP^O] IQ[\UYX @Y^X]UXS BZ]UO <XZ^]!CY`Q[! 6Q\USXM]Y[IYV]MSQ 5YVY[! BZ]UYX\55G BZ]UYX\ 5CK,/* 4 6@6@ Baj][l ;5;5 Fggc"&"Agj\ C6C6 N]f\Yfl 6 0.91#"(23ee)" Bjgh"J]fk 8 DdYl"J]fk 3 60U 4 96U 5 31U 7 145U 8 85U H?H? Sfan]jkYd 120-277T H;H; Sfan]jkYd 347-480T -"?nYadYZd]"oal`"@,"C"&"D"afhml"hgo]j" ""\]ka_fYlgjk"gfdq -.% 347T -"?"&"A"afhml"hgo]j"\]ka_fYlgjk"gfdq .1% 480T -"?"&"A"afhml"hgo]j"\]ka_fYlgjk"gfdq 4>4> @dY[c 4L4L @jgfr] FIFI Qadn]j" J;J; U`al] -*> 3000I .*> 4000I /0> 5700I 6<@ *'+*I!6UWWUXS -Agfljgd"Zq"gl`]jk -P]^]j"lg"Baeeaf_"kh]["k`]]l"^gj"\]lYadk -AYf'l"]p[]]\"oYllY_]"g^"kh][a^a]\"Gfhml"Ngo]j"B]ka_fYlgj ;L;L 5VM\\!<&!6U_(!,!;McM[PY^\!?YOM]UYX!5Q[]URUOM]UYX -?nYadYZd]"oal`"BK"Yf\"NB"egmflk"gfdq -Lgl"YnYadYZd]"oal`"BGK,"I,"gj"NKJ"ghlagfk -?"&"A"afhml"hgo]j"\]ka_fYlgjk"YnYadYZd]"af"SJ"ngdlY_]" gfdq > AF8!,!5Q[]URUOM]UYX -JmeafYaj]k"af[dm\]"LQD"[]jla^a[Ylagf"eYjc -?nYadYZd]"oal`"l`]"BK"egmfl"gfdq -Lgl"YnYadYZd]"oal`"l`]"FX"gj"NKJ"ghlagfk C@? C[YS[MWWMNVQ!@^V]U'?Q_QV -?nYadYZd]"oal`"SJ"ngdlY_]"gfdq -P]^]j"lg"NKJ"kh]["k`]]l"^gj"\]lYadk C[YP^O]!6Q\O[UZ]UYX R`]"ANW250€"JCB"AYfghq/Qg^^al"JmeafYaj]"`Yk"Yf"]plj]e]dq"l`af"hjg^ad]"[gfkljm[l]\"g^"jm__]\"[Ykl" Ydmeafme."Gl"[Yf"Z]"kmj^Y[]"egmfl]\"]Ykadq"^jge"Z]dgo"l`]"[Yfghq"\][c"Yf\"[Yf"Z]"h]f\Yfl"egmfl]\." Baj][l"aeY_af_"g^"l`]"JCBk"ak"]daeafYl]\"oal`"Y"`a_`dq"]^^a[a]fl"hYll]jf]\"^dYl"gj"0.91#"(23ee)"\jgh"_dYkk" d]fk. 3ZZVUOM]UYX\2"N]ljgd]me"[Yfgha]k,"ALE"^m]daf_"klYlagfk,"kg^^alk 3OOQ\\Y[UQ\! 8UQVP'<X\]MVVQP 6U[QO]!@Y^X]!?^WUXMU[Q\ 5MXYZb!HZS[MPQ!>U]\!#+1!SM(!\]QQV$ V?-@VAAKU"{"^gj"mk]"oal`"H]l-N`adahk,"21.60#"(549ee)"kimYj] V?-@VAALU"{"^gj"mk]"oal`"Cdk[g"DjYf[ak[Yf,"22.06#"(560ee)"kimYj] V?-@VAANU"{"^gj"mk]"oal`"JQG"BYcglY"gj"KYkl]jk,"22.50#"(572ee)"kimYj] V?-@VAAOU"{"^gj"mk]"oal`"U`al]oYq"Pana]jY"gj"Pa_-?-Jal],""20.60#"(523ee) kimYj] V?-@VAAPU"{"^gj"mk]"oal`"Cdk[g"K]jjal,"18.06#"(459ee)"kimYj] V?-@VAAQU"{"^gj"mk]"oal`"JQG"Pa[`egf\"gj"U`al]oYq"Aana[,"23.00#"(584ee)"J" p"13.00#"(330ee)"U 6U[QO]!@Y^X]!=^XO]UYX!4Ya)F]QW!>U] V?-@VAAH@MV"{"6.0#"(152ee)"F"p"3/4#"(19ee)"LNR"Ql]e -"UYl]jla_`l -"PYl]\"^gj"^]]\"l`jgm_`"8"(4"af,"4"gml)"$12"?UA"[gf\m[lgjk 6U[QO]!@Y^X]!4QM^]b!CVM]Q\ V?-@VAA@NU"{"26.17#"(665ee)"@]Ymlq"NdYl]"Mfdq"(18"_Y."kl]]d) V?-@VAA@N@12U"{"26.17#"(665ee)"@]Ymlq"NdYl]"(18"_Y."kl]]d)"o/12#"(305ee)" @Y[c]j"NdYl]"(16"_Y."kl]]d) -"Dgj"mk]"af"[Yfgha]k"o`]j]"\][c"gh]faf_"ak"dYj_]j"l`Yf"o`Yl"ak j]imaj]\"^gj ""egmflaf_"l`]"ANW250"dmeafYaj]."KYpaeme"\][c gh]faf_"10.75#"p"15#" ""(183ee"p"375ee) V?-@VAA@N@16U"{"26.17#"(665ee)"@]Ymlq"NdYl]"(18"_Y."kl]]d)"o/16#"(406ee)" @Y[c]j"NdYl]"(16"_Y."kl]]d) -"Dgj"mk]"af"[Yfgha]k"o`]j]"\][c"gh]faf_"ak"dYj_]j"l`Yf"o`Yl"ak" j]imaj]\"^gj ""egmflaf_"l`]"ANW250"dmeafYaj]."KYpaeme"\][c gh]faf_"12#"p"15#" ""(305ee"p"375ee) CQXPMX]!@Y^X]!?^WUXMU[Q\ CQXPMX]!@Y^X]!>U]\ V?-NQ12IGR*"{"5#"(127ee)"h]f\Yfl" V?-NQ18IGR*"{"11#"(279ee)"h]f\Yfl V?-NQ22IGR*"{"15#"(381ee)"h]f\Yfl" -"Gf[dm\]k"log"[gf\mal"^allaf_k"Yf\" """3/4-14"LNR"hah]"l`j]Y\]\"gf"log """]f\k ;MXP';QVP!EQWY]Q V?-QCLQPCK -"Dgj"km[[]kk^md"aehd]e]flYlagf"g^"l`] """hjg_jYeeYZd]emdla-d]n]d"ghlagf,"Y """eafaeme"g^"gf]"`Yf\-`]d\j]egl] """ak"j]imaj]\ ?kk]eZd]\"af"l`]"S.Q.?."g^"S.Q."Yf\"aehgjl]\"hYjlk <XU]UMV!6QVU_Q[QP!?^WQX\2"Sh"lg"20,080 7RRUOMOb2 Sh"lg"151"JNU 5E<2"Kafaeme"70"APG 55G2"3000I"(+/-"300I),"4000I"(+/-"300I),"5700I"(+/-"500I) ?UWU]QP!JM[[MX]bf2"10"q]Yjk"gf"dmeafYaj]/10"q]Yjk"gf"Agdgj^Ykl"B]dlYEmYj\€"^afak`" GN66"PYl]\"(Baj][l"Kgmfl"gfdq)" AdYkk"G,"Banakagf"2"FYrYj\gmk"Jg[Ylagf"^gj"k]d][l"eg\]dk" CQ[RY[WMXOQ!F^WWM[b 3LJK!8CIM 5GAN!8CIM 6@!@Y^X] @?>=<;9;897<?6 549;893210/9.-,+**) (?'84&9(5;85; %$3/9.-#**)9"!u9 (8'w5;9€';& ‚85';>9ƒ;„9.3)9 75446<w97<6vx7<?6'y9 7„<<;9‚<;?697z<ƒ> ,2#-/ .1%**)9 {849|<'> -02,/ .%+1**) }21/ .-+%**) --2,/ .1}#**) 12,/9 .0,**) ~6?;9@6?>>9|<'> u"Q]]"`llh;//da_`laf_.[j]].[ge/oYjjYflq"^gj"oYjjYflq"l]jek *Kmkl"kh][a^q"[gdgj JQUST] 12.5"dZk."(5.7c_) *"347"Yf\"480T"oal`"?"&"A"afhml"hgo]j"\]ka_fYlgjk"mladar]"Y"eY_f]la["kl]h-\gof"ljYfk^gje]j."Dgj"afhml"hgo]j"^gj"347"Yf\"480T,"j]^]j"lg"l`]"Cd][lja[Yd"BYlY"lYZd] ))+#$""&"(,")" ""0+"11"$#* (+03;  % GC TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLANMOUNTED AND ALL NECESSARY HARDWARE IS SPECIFIED FORSPECIFIED INSTALLATION PRIOR TO PURCHASING             $%/('+"0(,+ DMDM F C ULUL XXXX 40K 2020-160821 12/07/20 >!!#.&&$!(),%,.&&!!!!5!!#(,($!+&*%+*'+ HF2!!VUST]UXS(O[QQ(OYW >!!#.&&$!*-)%'()*!!!!5!!#.&&$!./&%-+&-5MXMPM2!!```(O[QQ(OYW)OMXMPM C[YP^O]!FZQOURUOM]UYX\ 5BAFGEH5G<BA!"!@3G7E<3?F z" Qdae,"dgo"hjg^ad]"\]ka_f z" CYkq"egmflaf_""Yf\"k]jna[af_"^jge"Z]dgo"l`]"\][c z" JmeafYaj]"`gmkaf_"ak"[gfkljm[l]\"g^"jm__]\"[Ykl"Ydmeafme"oal`"afl]_jYd"`]Yl" kafc"kh][a^a[Yddq"\]ka_f]\"^gj"JCB" z" DdYl"d]fk"ak"0.125#"l]eh]j]\"Qgdal]€"_dYkk z" Bjgh"d]fk"ak"0.157#"egd\]\"Zgjgkada[Yl]"_dYkk z" Baj][l"egmfl"ak"kmalYZd]"^gj"mk]"af"kaf_d]"gj"\gmZd]"kcaf"[Yfgha]k"oal`"Y" eafaeme"4.0#"(102ee)"oa\]"hYf]dk"Yf\"Y"eafaeme"22"_Ym_],"0.030#"(0.7ee)" [Yfghq"l`a[cf]kk z" Baj][l"egmfl"dmeafYaj]"egmflk"\aj][ldq"lg"l`]"[Yfghq"\][c"oal`"l`]"\jaddaf_" g^"Y"kaf_d]"2#"lg"4#"(51ee"lg"102ee)"jgmf\"`gd],"ak"k][mj]\"af"hdY[]"oal`" k]d^-k]Ydaf_"k[j]ok"l`Yl"hjgna\]"Y"o]Yl`]jla_`l"k]Yd"Yf\"af[dm\]k"3/4y"(19ee)" [gf\mal"]fljq"^gj"\aj][l"oaj]"^]]\ z" Fggc"Yf\"[gj\"egmfl"af[dm\]k"Y"3'"(0.91e)"[gj\"gml"g^"l`]"dmeafYaj]"Yf\"ak" afl]f\]\"lg"`Yf_"^jge"l`]"kaf_d]"`ggc z" QlYf\Yj\"h]f\Yfl"egmfl"af[dm\]k"Y"egmflaf_"ZjY[c]l"Yf\"Y"H-@gp"^gj" [mklge]j"oajaf_"Yf\"ak"afl]f\]\"lg"Z]"egmfl]\"Zq"3/4"GN"h]f\Yfl"(Zq"gl`]jk)" z" FYrYj\gmk"dg[Ylagf"h]f\Yfl"egmfl"`Yk"Y"l`j]Y\]\"`mZ"o`a[`"Y[[]hlk"3/4#" LNR"[gf\mal"(Zq"gl`]jk)"Yf\"k][mj]k"oal`"Y"1/4#-20"k]l"k[j]o z" Cp[dmkan]"Agdgj^Ykl"B]dlYEmYj\€"^afak`"^]Ylmj]k"Yf"C-AgYl"]hgpq"hjae]j"oal`" Yf"mdljY-\mjYZd]"hgo\]j"lgh[gYl,"hjgna\af_"]p[]dd]fl"j]kaklYf[]"lg"[gjjgkagf," mdljYnagd]l"\]_jY\Ylagf"Yf\"YZjYkagf."@dY[c,"Zjgfr],"kadn]j"Yf\"o`al]"Yj]" YnYadYZd] z" JQUST]2"12.5"dZk."(5.7c_) 7?75GE<53?!FKFG7@ z" <XZ^]!IYV]MSQ2"120-277T"gj"347-480T,"50/60Fr,"AdYkk"1"\jan]jk z" CY`Q[!8MO]Y[2 ">"0.9"Yl"^mdd"dgY\ z" GY]MV!;M[WYXUO!6U\]Y[]UYX2!="20%"Yl"^mdd"dgY\ z" Gfl]_jYd"6cT"kmj_]"kmhhj]kkagf"hjgl][lagf"klYf\Yj\ z" U`]f"[g\]"\a[lYl]k"^mkaf_,"Y"kdgo"Zdgo"^mk]"gj"lqh]"A/B"Zj]Yc]j"k`gmd\"Z]" mk]\"lg"Y\\j]kk"afjmk`"[mjj]fl j! BZQ[M]UXS!GQWZQ[M]^[Q!EMXSQ2!?hhda[Ylagfk"P]imajaf_"AdYkk"G,"Banakagf"2"" FYrYj\gmk"Jg[Ylagf"PYlaf_k;"-40!A"lg"+25!A<"?"Gfhml"Ngo]j"B]ka_fYlgj;"-40!A" lg"+40!A"(\aj][l"egmfl"lg"hdqogg\),"-40!A"lg"+45!A"(\aj][l"egmfl"lg"k`]]l" e]lYd/kmkh]f\]\)<"@"&"C"Gfhml"Ngo]j"B]ka_fYlgjk;"-40!A"lg"+35!A"(hdqogg\)," -40!A"lg"+40!A"(k`]]l"e]lYd/kmkh]f\]\)<"A"Gfhml"Ngo]j"B]ka_fYlgj;"-40!A"lg" +45!A"(hdqogg\),"-40!A"lg"+50!A"(k`]]l"e]lYd/kmkh]f\]\)<"D"Gfhml"Ngo]j"" B]ka_fYlgj;"-40!A"lg"+40!A"(hdqogg\),"-40!A"lg"+45!A"(k`]]l"e]lYd/" kmkh]f\]\)" J3EA<A92"Cp[]]\af_"eYpaeme"gh]jYlaf_"l]eh]jYlmj]"eYq"j]kmdl"af" l`]jeYd"^gd\ZY[c 5BAGEB?F z" Agflafmgmk"\aeeaf_"lg"10%"oal`"0-10T"BA"[gfljgd"hjglg[gd j! +*I!FY^[OQ!5^[[QX]2"0.15e? z" Sk]"gfdq"da_`laf_"[gfljgdk"oal`"f]mljYd"[gff][lagf"gj"[gfljgdk"afl]f\]\"^gj"mk]" oal`"JCB"^aplmj]k z" P]^]j]f[]"JCB"Baeeaf_"kh]["k`]]l"^gj"Y\\alagfYd"\aeeaf_"af^gjeYlagf E79H?3GBEK!"!IB?HAG3EK!DH3?<8<53G<BAF z" [SJmk"Jakl]\ z" QmalYZd]"^gj"o]l"dg[Ylagfk"o`]f"gj\]j]\"oal`"BK"egmfl z" QmalYZd]"^gj"\Yeh"dg[Ylagfk"o`]f"gj\]j]\"oal`"FA"Yf\"NB"egmflk z" QmalYZd]"^gj"o]l"dg[Ylagfk"o`]f"gj\]j]\"oal`"NB"egmfl"Yf\"FX"ghlagf z" Cf[dgkmj]"jYl]\"GN66"h]j"GCA"60529"o`]f"gj\]j]\"oal`"BK"egmfl z" Agfkmdl"^Y[lgjq"^gj"AC"A]jla^a]\"hjg\m[lk z" 6cT"kmj_]"kmhhj]kkagf"hjgl][lagf"l]kl]\"af"Y[[gj\Yf[]"oal`"GCCC/?LQG" A62.41.2 z" K]]lk"DAA"NYjl"15,"QmZhYjl"@,"AdYkk"?"klYf\Yj\k"^gj"[gf\m[l]\"Yf\"jY\aYl]\" ]eakkagfk z" JmeafYaj]"Yf\"^afak`"]f\mjYf[]"l]kl]\"lg"oal`klYf\"5,000"`gmjk"g^"]d]nYl]\" YeZa]fl"kYdl"^g_"[gf\alagfk"Yk"\]^af]\"af"?QRK"QlYf\Yj\"@"117 z" K]]lk"@mq"?e]ja[Yf"j]imaj]e]flk"oal`af"?PP? z" PgFQ"[gehdaYfl."Agfkmdl"^Y[lgjq"^gj"Y\\alagfYd"\]lYadk z" AdYkk"G,"Banakagf"2"FYrYj\gmk"Jg[Ylagf"jYl]\"o`]f"gj\]j]\"oal`"l`]"BK"gj"NB" egmfl"Yf\"l`]"FX"ghlagf."?"&"A"afhml"hgo]j"\]ka_fYlgjk"Yj]"YnYadYZd]"af"SJ" ngdlY_]"gfdq."Lgl"YnYadYZd]"oal`"BGK,"LQD"gj"NKJ"ghlagfk."PYl]\"^gj"Ejgmhk" ?,"@,"A"&"B."@]Yjk"Y"R3A"(160!A)"l]eh]jYlmj]"[dYkka^a[Ylagf"oal`af"Y"25!A" YeZa]fl z" LQD"A]jla^a]\"o`]f"gj\]j]\"oal`"BK"egmfl."Lgl"YnYadYZd]"oal`"FX"gj"NKJ" ghlagfk."P]^]j"lg"`llh;//af^g.fk^.gj_/A]jla^a]\/Dgg\/"^gj"Y\\alagfYd"\]lYadk z" BJA"Yf\"BJA"Nj]eame"imYda^a]\"n]jkagfk"YnYadYZd]."Nd]Yk]"j]^]j"lg" `llhk;//ooo.\]ka_fda_`lk.gj_/k]Yj[`/"^gj"egkl"[mjj]fl"af^gjeYlagf +"Jme]f"eYafl]fYf[]"nYdm]k"Yl"25!A"(77!D)"Yj]"[Yd[mdYl]\"h]j"RK-21"ZYk]\"gf"JK-80"\YlY"Yf\"af-kalm"dmeafYaj]"l]klaf_" ""gf"k`]]l"e]lYd ,"Gf"Y[[gj\Yf[]"oal`"GCQL?"RK-21-11,"Njgb][l]\"TYdm]k"j]hj]k]fl"afl]jhgdYl]\"nYdm]"ZYk]\"gf"lae]"\mjYlagfk"l`Yl"Yj]"" ""oal`af"kap"lae]k"(6V)"l`]"GCQL?"JK-80-08"lglYd"l]kl"\mjYlagf"(af"`gmjk)"^gj"l`]"\]na[]"mf\]j"l]klaf_"((BSR)"a.]."l`]" ""hY[cY_]\"JCB"[`ah) 3"Gf"Y[[gj\Yf[]"oal`"GCQL?"RK-21-11,"AYd[mdYl]\"TYdm]k"j]hj]k]fl"lae]"\mjYlagfk"l`Yl"]p[]]\"kap"lae]k"(6V)"l`]"GCQL?" ""JK-80-08"lglYd"l]kl"\mjYlagf"(af"`gmjk)"^gj"l`]"\]na[]"mf\]j"l]klaf_"((BSR)"a.]."l`]"hY[cY_]\"JCB"[`ah) 7VQO][UOMV!6M]M% Gfhml" Ngo]j B]ka_fYlgj Qqkl]e" UYllk 120-277T Qqkl]e" UYllk 347-480T<" 347/480T RglYd"Amjj]fl"(?) 120T 208T 240T 277T 347T 480T ? 60 68 0.51 0.29 0.25 0.22 0.20 0.14 @ 96 96 0.82 0.47 0.40 0.35 0.28 0.20 A 31 33 0.26 0.15 0.13 0.11 0.10 0.07 C 145 145 1.22 0.70 0.61 0.53 0.42 0.30 D 85 85 #")% #"'$ #"&( #"&$ #"%' #"$* ANW250€"JCB"AYfghq/Qg^^al"JmeafYaj]"-"T]jkagf"@ *"Cd][lja[Yd"\YlY"Yl"25!A"(77!D)."?[lmYd"oYllY_]"eYq"\a^^]j"Zq"+/-"10%"o`]f"gh]jYlaf_"Z]lo]]f"120-480T"+/-"10% EQOYWWQXPQP!5CK!FQ[UQ\!'!IQ[\UYX!4!?^WQX!@MUX]QXMXOQ!8MO]Y[\!#?@8$+ ?eZa]fl GfalaYd"JKD 25I"`j Njgb][l]\2 JKD 50I"`j Njgb][l]\2 JKD 75I"`j AYd[mdYl]\3 JKD 100I"`j AYd[mdYl]\3 JKD 5!A"(41!D) 1.04 1.02 1.00 0.98 0.96 10!A"(50!D) 1.03 1.01 0.99 0.97 0.95 15!A"(59!D) 1.02 0.99 0.98 0.96 0.94 20!A"(68!D) 1.01 0.98 0.96 0.95 0.93 25!A"(77!D) 1.00 0.97 0.95 0.94 0.92 30!A"(86!D) 0.99 0.96 0.94 0.93 0.91 2020-160821 12/07/20 >!!#.&&$!(),%,.&&!!!!5!!#(,($!+&*%+*'+ HF2!!VUST]UXS(O[QQ(OYW >!!#.&&$!*-)%'()*!!!!5!!#.&&$!./&%-+&-5MXMPM2!!```(O[QQ(OYW)OMXMPM CTY]YWQ][b ?dd"hmZdak`]\"dmeafYaj]"h`glge]lja["l]klaf_"h]j^gje]\"lg"GCQL?"JK-79-08"klYf\Yj\k"Zq"Y"LTJ?N"Y[[j]\al]\"dYZgjYlgjq."Rg"gZlYaf"Yf"GCQ"^ad]"kh][a^a["lg"qgmj"hjgb][l" [gfkmdl;"`llh;//da_`laf_.[j]].[ge/hjg\m[lk/gml\ggj/[Yfghq-Yf\-kg^^al/[hq-k]ja]k" ANW250€"JCB"AYfghq/Qg^^al"JmeafYaj]"-"T]jkagf"@ *"GfalaYd"\]dan]j]\"dme]fk"Yl"25!A"(77!D)."?[lmYd"hjg\m[lagf"qa]d\"eYq"nYjq"Z]lo]]f"-10"Yf\"+10%"g^"afalaYd"\]dan]j]\" """dme]fk **"Dgj"egj]"af^gjeYlagf"gf"l`]"GCQ"@SE"(@Y[cda_`l-Shda_`l-EdYj])"PYlaf_"nakal;"" """""`llhk;//ooo.a]k.gj_/oh-[gfl]fl/mhdgY\k/2017/03/RK-15-11@SEPYlaf_k?\\]f\me.h\^ 6EBC!?7AF 24=>8!>CMN!<CKJLN!";"NJ08412-001? ANW250-@-**-B-@-SJ-**-57I 7IFNFAG!3CGFPCLCB!8OHCIM;"12,403 "#!)"#!) (!) (!) '!)'!) $!) $!) "&!) "&!) $$*, &(&) '*$( /9D<B=FEL=G6G9;=- 8=GIA;9B FB9D=I@GEJ?@ @EGANEDI9B 9D?B=E>C9MACJC ;9D<B=FEL=G" %&(* ANW250-@-**-B-@-SJ-**-57I 9JOINFID!6CFDEN0"15'"(4.6e)"?.D.E. 7IFNFAG!3CGFPCLCB!8OHCIM0"12,860 GfalaYd"DA"Yl"_jY\] '& '% /75.2130 '$% $& %# #C $+"& $+"& $+"& #C#! )"$%#! )"$%#! )#! %'"'+#! %'"' $%"%'#! $%"%'#! '#! )#! %#! $%"% '#! )"$ %#! #! )#! %'"' +#!+#! 4EHAIAEDE>K=GIA;9BFB9D= E>C9MACJC ;9D<B=FEL=G" "$! )"$ $%"% +#! )#! $+"& %'"' 6[YZ!?QX\!6U\][UN^]UYX Gfhml" Ngo]j B]ka_fYlgj 3000I 4000I 5700I GfalaYd B]dan]j]\ Jme]fk* @SE PYlaf_k**" N]j" RK-15-11 GfalaYd B]dan]j]\ Jme]fk* @SE PYlaf_k**" N]j" RK-15-11 GfalaYd B]dan]j]\ Jme]fk* @SE PYlaf_k**" N]j" RK-15-11 ? 7,250" @3"S2"E1" 7,600" @3"S2"E1" 7,720" @3"S2"E1" @ 11,850" @3"S2"E1" 12,380" @3"S2"E1" 12,860" @3"S2"E1" A 4,210" @2"S2"E1 4,420" @2"S2"E1 4,520" @2"S2"E1 C 19,100" @4"S3"E2" 19,600" @4"S3"E2" 20,080" @4"S3"E2" D 11,850" @3"S2"E1" 12,380" @3"S2"E1" 12,860" @3"S2"E1! *"GfalaYd"\]dan]j]\"dme]fk"Yl"25!A"(77!D)."?[lmYd"hjg\m[lagf"qa]d\"eYq"nYjq"Z]lo]]f"-10"Yf\"+10%"g^"afalaYd"\]dan]j]\" """dme]fk **"Dgj"egj]"af^gjeYlagf"gf"l`]"GCQ"@SE"(@Y[cda_`l-Shda_`l-EdYj])"PYlaf_"nakal;"" """""`llhk;//ooo.a]k.gj_/oh-[gfl]fl/mhdgY\k/2017/03/RK-15-11@SEPYlaf_k?\\]f\me.h\^ 8?3G!?7AF 24=>8!>CMN!<CKJLN!";"NJ08165-001A" ANW250-@-**-D-@-SJ-**-57I 7IFNFAG!3CGFPCLCB!8OHCIM;"13,040 "#!)"#!) (!) (!) '!)'!) $!) $!) "&!) "&!) $$+$ &('% '*%& /9D<B=FEL=G6G9;=- 8=GIA;9B FB9D=I@GEJ?@ @EGANEDI9B 9D?B=E>C9MACJC ;9D<B=FEL=G" %&)$ ANW250-@-**-D-@-SJ-**-57I 9JOINFID!6CFDEN0"15'"(4.6e)"?.D.E. 7IFNFAG!3CGFPCLCB!8OHCIM0"12,860 GfalaYd"DA"Yl"_jY\] /75.2130 %$ %# %" $ # " $! $+"& $+"& $+"& #C#! )"$%#! )"$%#! )#! %'"'+#! %'"'+#! $%"%'#! $%"%'#! )#! '#! )#! %#! $%"% '#! %#! #! )#! %'"' +#!+#! 4EHAIAEDE>K=GIA;9B FB9D= E>C9MACJC ;9D<B=FEL=G" #C )"$ $%"% $+"& )"$%'"' %&) 8VM]!?QX\!6U\][UN^]UYX Gfhml" Ngo]j B]ka_fYlgj 3000I 4000I 5700I GfalaYd B]dan]j]\ Jme]fk* @SE PYlaf_k**" N]j" RK-15-11 GfalaYd B]dan]j]\ Jme]fk* @SE PYlaf_k**" N]j" RK-15-11 GfalaYd B]dan]j]\ Jme]fk* @SE PYlaf_k**" N]j" RK-15-11 ? 7,250" @3"S0"E1 7,600" @3"S0"E1 7,720" @3"S0"E1 @ 11,850" @3"S0"E1 12,380" @3"S0"E1 12,860" @3"S0"E1 A 4,210" @2"S0"E1 4,420" @2"S0"E1 4,520" @2"S0"E1 C 19,100" @4"S0"E1 19,600" @4"S0"E1 20,080" @4"S0"E1 D 11,850" @3"S0"E1 12,380" @3"S0"E1 12,860" @3"S0"E1 2020-160821 12/07/20 >!!#.&&$!(),%,.&&!!!!5!!#(,($!+&*%+*'+ HF2!!VUST]UXS(O[QQ(OYW >!!#.&&$!*-)%'()*!!!!5!!#.&&$!./&%-+&-5MXMPM2!!```(O[QQ(OYW)OMXMPM }!1/06!@i\\+!FeZ-!Xe[.fi!fe\!f]!`kj!jlYj`[`Xi`\j-!>cc!i`^_kj!i\j\im\[-!Cfi!`e]fidXk`feXc!gligfj\j!fecp-!@fek\ek!`j!jlYa\Zk!kf!Z_Xe^\- MXk\ek!nnn-Zi\\-Zfd.gXk\ekj-!@i\\!+!@fcfi]Xjk!A\ckXDlXi[!Xe[!@MV14/!Xi\!i\^`jk\i\[!kiX[\dXibj+!Xe[!k_\!@i\\!cf^f!`j!X! kiX[\dXib!f]!@i\\+!FeZ-!Q_\!RI!cf^f!`j!X!i\^`jk\i\[!kiX[\dXib!f]!RI!II@-!Q_\!KPC!cf^f!`j!X!i\^`jk\i\[!kiX[\dXib!f]!KPC Fek\ieXk`feXc-!Q_\!AI@!NMI!cf^f!`j!X!i\^`jk\i\[!kiX[\dXib+!Xe[!k_\!AI@!NMI!Mi\d`ld!cf^f!`j!X!kiX[\dXib!f]!Kfik_\Xjk!Be\i^p! B]]`Z`\eZp!MXike\ij_`gj+!FeZ- ANW250€"JCB"AYfghq/Qg^^al"JmeafYaj]"-"T]jkagf"@ ;5!@Y^X] .-,+* )('&%%$ .-,+* )('&%%$ #,(* ).+"%%$ !,+* ).-(%%$ ',+* )&+(%%$ C6!@Y^X] 98765 432100/ 98765 432100/ .-,+*,)(,') &,%$#+-+ 2765 416300/ 87"5 49!"00/ C6!@Y^X]!`);L!BZ]UYX @?>=< ;989776 @?>=< ;985776 9>=< ;4?>?776 5>=< ;?=776 3210/.21--/,+*- )('+1&+&/%$# "+0!"u'+w 9|}</~)/€*&$v0 "$xx2v+&/yz/{0(+'- 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 Dimensional Drawings For more detailed information on mounting, wiring or installation instructions, please consult factory. If poles are not ordered with fixtures, please specify mounting requirements. This document contains proprietary information of Visionaire Lighting  LLC. Any use of this information requires the written approval of Visionaire Lighting, LLC. In keeping with our TQM policy of continuous improvement, Visionaire reserves the right to change any specifications contained herein without prior notice. 28 American LED Model Optics Source Current Voltage Mounting Finish Bolt-On Arm 6” (BOA6) Bolt-On Arm 10” (BOA10) Knuckle Mount (KM) Wall Mount *Cast Wall Plate (BAWP) to be ordered separately (WM) Spider Mount Fits 2 3/8” O.D. (SM) Round Pole Plate Adaptors (RPP) are to be ordered separately. Bronze (BZ) Black (BK) Smooth Black (SBK) White (WH) Smooth White (SWH) Graphite (GP) Grey (GY) Silver Metallic (SL) Custom Color (CC) Kelvin 3000K *Warm white (3K) 4000K *Neutral white (4K) 5000K *Cool white (5K) 120-277 *Universal voltage (UNV) 480 (5) 347 (8) mA 350 (3) 530 (5) Type II (T2) Type III (T3) Type IV (T4) Type IV-A (T4A) Type V (T5) Type V-W (T5W) # of LEDs 72 (72LC) 144 (144LC) 224 (224LC) AME-2-L AME-4-L Photocell & Receptacle *Specify Voltage (PCR120) (PCR208) (PCR240) (PCR277) *Specify BOA or Spider Mount Photo & Receptacle with shorting cap (PER) *Specify BOA or Spider Mount Button Type Photocell *Specify Voltage (PC120) (PC208) (PC240) (PC277) House Side Light Shield (LS) Round Pole Plate Adapter (RPP) 0-10v Dimming Driver No Controls (DIM) Wireless Controls Consult Factory (WS) Motion Sensor/Control Watt Stopper FSP-211 8’ Mounting Height Must specify Dimming Driver. *120V-277V Only (WSC-8) 8’ Mounting Height (WSC-20) 9-20’ Mounting Height (WSC-40) 21-40’ Mounting Height This option will require(1) FSIR 100 remote for programing Motion Sensor (MS-8) 8’ Mounting Height (MS-20) 9-20’ Mounting Height (MS-40) 21-40’ Mounting Height Options Fixture A B C Stripe Max. Watts Lbs. AME-2-L 19” 19” 12” 2” 238 W 29 AME-4-L 23” 23” 15” 2” 373 W 68 A B C The new American LED Luminaire from Visionaire combines contemporary design with new LED technology; while maintaining a traditional fixture image. The LEDs Performance and Life are maximized by the unique integral aluminum heat sink built into the door frame. Maintenance of the drivers is simplified by making them easily accessible and provided with quick wiring connections. 72, 144 or 224 LEDs are available in 350 or 530 mA rating providing up to 33,000 lumens. Six optical distribution patterns are available and feature a unique Type T-4A automotive pattern for the front row of auto dealerships. Choose between 3000, 4000 or 5000 Kelvin temperature of the LEDs. A durable Polyester powder coat finish is guaranteed for five years; and is available in standard or custom colors. The American LED series is an exceptional choice for auto dealerships, shopping centers, commercial parking lots and general parking area lighting. AR E A Project Name: Catalog Number: Type CAW-432 : UU1 AME-2-L T4 144LC 5 4K UNV BOA6 WH GC TO VERIFY ALL INFORMATION BELOW GC SEE NOTES BELOW 2020-160821 12/07/20 19645 Rancho Way Rancho Dominguez, CA 90220 Tel: (310) 512-6480 Fax: (310) 512-6486 www.visionairelighting.com 29 American LED EPA Data Fixture with Arm AME-2 2.2 4.0 4.4 6.0 5.1 7.1 2.6 AME-4 3.4 6.2 6.8 9.2 7.8 10.9 3.9 Housing • All housings are manufactured using advanced computerized numerical control (CNC) machinery. Precision sheared and formed from one-piece, corrosion-resistant aluminum, with tooled external reveal. • The computerized CNC machinery enables all American housings to be constructed quickly, efficiently and adhering to exacting ISO 9002 standards. All external hardware is stainless steel. Door Assembly • Removable hinged door assembly is CNC precision, sheared and formed from one- piece, corrosion-resistant aluminum with captive stainless steel fastener The LEDs and drivers are mounted to an aluminum heat sink that is attached to the door frame. Optical System • The LED light assemblies come with up to 224 LEDs. Six IES distribution patterns are offered as standard; with a unique Type 4 Automotive optic available for Dealerships. The optical system qualifies as IES full cutoff; to restrict light trespass, glare, and light pollution. Quali-Guard Finish • The finish is Quali-Guard textured, chemically pretreated through a multiple-stage washer, electrostatically applied, thermoset polyester powder coat finish, with a minimum of 3-5 millimeter thickness. Finish is oven-baked at 400ºF to promote maximum adherence and finish hardness. All finishes are available in standard and custom colors Mounting • A rounded extruded aluminum, Bolt-On Arm (BOA), with an in-pole nut plate, securing (2) inch zinc running bolts with stainless steel hardware is standard. A Round Pole Plate Adaptor (RPP) is required for mounting to 3” - 5” round poles. Electrical Assembly • The American LED Series is supplied with a choice of 350 or 530 mA high- performance LED drivers that accept 120 v thru 480v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40°C operations. • 10 kV surge protector supplied as standard. Warranty • Five (5) year Limited Warranty on entire system, including finish. For full warranty information, visit www.visionairelighting.com Options • Photocell & Receptacle • Photo receptacle • Button type photocell • House side light shield • Round pole plate adaptor • Dimming Driver • Wireless Controls • Motion Sensor Please consult factory for custom options. Listings • American is ETL listed, suitable for wet locations • IP65 Rated • LM79 and LM80. • EISA compliant. • RoHS compliant • Powder Coated Tough™ • DLC Listed AR E A DesignLights Consortium (DLC) qualified Product. Some configurations of this product family may not be DesignLights Consortium (DLC) listed, please refer to the DLC qualified products list to confirm listed configurations. http://www.designlights.org/ American 5K LED LUMEN DATA # of LEDs mA Type 2 B U G Type 3 B U G Type 4 B U G Type 4A B U G Type 5 B U G Type 5W B U G Watts 72 350 8,470 2 0 2 7,485 2 0 2 8,401 2 0 2 8,069 1 0 1 9,174 3 0 1 9,145 3 0 1 80 530 11,883 3 0 3 10,501 2 0 2 11,786 2 0 2 11,321 2 0 1 12,871 3 0 1 12,830 3 0 1 120 144 350 16,423 3 0 3 14,513 3 0 3 16,289 2 0 3 15,656 2 0 1 17,789 4 0 1 17,732 4 0 2 160 530 21,913 3 0 3 19,365 3 0 3 21,734 3 0 3 20,876 2 0 2 23,736 4 0 2 25,249 4 0 2 238 224 350 24124 3 0 3 22443 3 0 3 24480 3 0 3 24322 2 0 2 26734 5 0 2 26285 5 0 2 246 530 32982 4 0 4 30683 3 0 3 33468 3 0 3 33252 3 0 2 36550 5 0 2 35935 5 0 2 377 Visit www.visionairelighting.com for up-to-the-minute chart information, including types not listed here. * For 4000K multiply values by 0.98 * For 3000K multiply values by 0.95 2020-160821 12/07/20 Dimensional Drawings For more detailed information on mounting, wiring or installation instructions, please consult factory. If poles are not ordered with fixtures, please specify mounting requirements. This document contains proprietary information of Visionaire Lighting  LLC. Any use of this information requires the written approval of Visionaire Lighting, LLC. In keeping with our TQM policy of continuous improvement, Visionaire reserves the right to change any specifications contained herein without prior notice. 28 American LED Model Optics Source Current Voltage Mounting Finish Bolt-On Arm 6” (BOA6) Bolt-On Arm 10” (BOA10) Knuckle Mount (KM) Wall Mount *Cast Wall Plate (BAWP) to be ordered separately (WM) Spider Mount Fits 2 3/8” O.D. (SM) Round Pole Plate Adaptors (RPP) are to be ordered separately. Bronze (BZ) Black (BK) Smooth Black (SBK) White (WH) Smooth White (SWH) Graphite (GP) Grey (GY) Silver Metallic (SL) Custom Color (CC) Kelvin 3000K *Warm white (3K) 4000K *Neutral white (4K) 5000K *Cool white (5K) 120-277 *Universal voltage (UNV) 480 (5) 347 (8) mA 350 (3) 530 (5) Type II (T2) Type III (T3) Type IV (T4) Type IV-A (T4A) Type V (T5) Type V-W (T5W) # of LEDs 72 (72LC) 144 (144LC) 224 (224LC) AME-2-L AME-4-L Photocell & Receptacle *Specify Voltage (PCR120) (PCR208) (PCR240) (PCR277) *Specify BOA or Spider Mount Photo & Receptacle with shorting cap (PER) *Specify BOA or Spider Mount Button Type Photocell *Specify Voltage (PC120) (PC208) (PC240) (PC277) House Side Light Shield (LS) Round Pole Plate Adapter (RPP) 0-10v Dimming Driver No Controls (DIM) Wireless Controls Consult Factory (WS) Motion Sensor/Control Watt Stopper FSP-211 8’ Mounting Height Must specify Dimming Driver. *120V-277V Only (WSC-8) 8’ Mounting Height (WSC-20) 9-20’ Mounting Height (WSC-40) 21-40’ Mounting Height This option will require(1) FSIR 100 remote for programing Motion Sensor (MS-8) 8’ Mounting Height (MS-20) 9-20’ Mounting Height (MS-40) 21-40’ Mounting Height Options Fixture A B C Stripe Max. Watts Lbs. AME-2-L 19” 19” 12” 2” 238 W 29 AME-4-L 23” 23” 15” 2” 373 W 68 A B C The new American LED Luminaire from Visionaire combines contemporary design with new LED technology; while maintaining a traditional fixture image. The LEDs Performance and Life are maximized by the unique integral aluminum heat sink built into the door frame. Maintenance of the drivers is simplified by making them easily accessible and provided with quick wiring connections. 72, 144 or 224 LEDs are available in 350 or 530 mA rating providing up to 33,000 lumens. Six optical distribution patterns are available and feature a unique Type T-4A automotive pattern for the front row of auto dealerships. Choose between 3000, 4000 or 5000 Kelvin temperature of the LEDs. A durable Polyester powder coat finish is guaranteed for five years; and is available in standard or custom colors. The American LED series is an exceptional choice for auto dealerships, shopping centers, commercial parking lots and general parking area lighting. AR E A Project Name: Catalog Number: Type CAW-432 : UU2 AME-2-L T2 72LC 5 4K UNV BOA6 WH GC TO VERIFY ALL INFORMATION BELOW GC SEE NOTES BELOW 2020-160821 12/07/20 19645 Rancho Way Rancho Dominguez, CA 90220 Tel: (310) 512-6480 Fax: (310) 512-6486 www.visionairelighting.com 29 American LED EPA Data Fixture with Arm AME-2 2.2 4.0 4.4 6.0 5.1 7.1 2.6 AME-4 3.4 6.2 6.8 9.2 7.8 10.9 3.9 Housing • All housings are manufactured using advanced computerized numerical control (CNC) machinery. Precision sheared and formed from one-piece, corrosion-resistant aluminum, with tooled external reveal. • The computerized CNC machinery enables all American housings to be constructed quickly, efficiently and adhering to exacting ISO 9002 standards. All external hardware is stainless steel. Door Assembly • Removable hinged door assembly is CNC precision, sheared and formed from one- piece, corrosion-resistant aluminum with captive stainless steel fastener The LEDs and drivers are mounted to an aluminum heat sink that is attached to the door frame. Optical System • The LED light assemblies come with up to 224 LEDs. Six IES distribution patterns are offered as standard; with a unique Type 4 Automotive optic available for Dealerships. The optical system qualifies as IES full cutoff; to restrict light trespass, glare, and light pollution. Quali-Guard Finish • The finish is Quali-Guard textured, chemically pretreated through a multiple-stage washer, electrostatically applied, thermoset polyester powder coat finish, with a minimum of 3-5 millimeter thickness. Finish is oven-baked at 400ºF to promote maximum adherence and finish hardness. All finishes are available in standard and custom colors Mounting • A rounded extruded aluminum, Bolt-On Arm (BOA), with an in-pole nut plate, securing (2) inch zinc running bolts with stainless steel hardware is standard. A Round Pole Plate Adaptor (RPP) is required for mounting to 3” - 5” round poles. Electrical Assembly • The American LED Series is supplied with a choice of 350 or 530 mA high- performance LED drivers that accept 120 v thru 480v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40°C operations. • 10 kV surge protector supplied as standard. Warranty • Five (5) year Limited Warranty on entire system, including finish. For full warranty information, visit www.visionairelighting.com Options • Photocell & Receptacle • Photo receptacle • Button type photocell • House side light shield • Round pole plate adaptor • Dimming Driver • Wireless Controls • Motion Sensor Please consult factory for custom options. Listings • American is ETL listed, suitable for wet locations • IP65 Rated • LM79 and LM80. • EISA compliant. • RoHS compliant • Powder Coated Tough™ • DLC Listed AR E A DesignLights Consortium (DLC) qualified Product. Some configurations of this product family may not be DesignLights Consortium (DLC) listed, please refer to the DLC qualified products list to confirm listed configurations. http://www.designlights.org/ American 5K LED LUMEN DATA # of LEDs mA Type 2 B U G Type 3 B U G Type 4 B U G Type 4A B U G Type 5 B U G Type 5W B U G Watts 72 350 8,470 2 0 2 7,485 2 0 2 8,401 2 0 2 8,069 1 0 1 9,174 3 0 1 9,145 3 0 1 80 530 11,883 3 0 3 10,501 2 0 2 11,786 2 0 2 11,321 2 0 1 12,871 3 0 1 12,830 3 0 1 120 144 350 16,423 3 0 3 14,513 3 0 3 16,289 2 0 3 15,656 2 0 1 17,789 4 0 1 17,732 4 0 2 160 530 21,913 3 0 3 19,365 3 0 3 21,734 3 0 3 20,876 2 0 2 23,736 4 0 2 25,249 4 0 2 238 224 350 24124 3 0 3 22443 3 0 3 24480 3 0 3 24322 2 0 2 26734 5 0 2 26285 5 0 2 246 530 32982 4 0 4 30683 3 0 3 33468 3 0 3 33252 3 0 2 36550 5 0 2 35935 5 0 2 377 Visit www.visionairelighting.com for up-to-the-minute chart information, including types not listed here. * For 4000K multiply values by 0.98 * For 3000K multiply values by 0.95 2020-160821 12/07/20 Dimensional Drawings For more detailed information on mounting, wiring or installation instructions, please consult factory. If poles are not ordered with fixtures, please specify mounting requirements. This document contains proprietary information of Visionaire Lighting  LLC. Any use of this information requires the written approval of Visionaire Lighting, LLC. In keeping with our TQM policy of continuous improvement, Visionaire reserves the right to change any specifications contained herein without prior notice. 28 American LED Model Optics Source Current Voltage Mounting Finish Bolt-On Arm 6” (BOA6) Bolt-On Arm 10” (BOA10) Knuckle Mount (KM) Wall Mount *Cast Wall Plate (BAWP) to be ordered separately (WM) Spider Mount Fits 2 3/8” O.D. (SM) Round Pole Plate Adaptors (RPP) are to be ordered separately. Bronze (BZ) Black (BK) Smooth Black (SBK) White (WH) Smooth White (SWH) Graphite (GP) Grey (GY) Silver Metallic (SL) Custom Color (CC) Kelvin 3000K *Warm white (3K) 4000K *Neutral white (4K) 5000K *Cool white (5K) 120-277 *Universal voltage (UNV) 480 (5) 347 (8) mA 350 (3) 530 (5) Type II (T2) Type III (T3) Type IV (T4) Type IV-A (T4A) Type V (T5) Type V-W (T5W) # of LEDs 72 (72LC) 144 (144LC) 224 (224LC) AME-2-L AME-4-L Photocell & Receptacle *Specify Voltage (PCR120) (PCR208) (PCR240) (PCR277) *Specify BOA or Spider Mount Photo & Receptacle with shorting cap (PER) *Specify BOA or Spider Mount Button Type Photocell *Specify Voltage (PC120) (PC208) (PC240) (PC277) House Side Light Shield (LS) Round Pole Plate Adapter (RPP) 0-10v Dimming Driver No Controls (DIM) Wireless Controls Consult Factory (WS) Motion Sensor/Control Watt Stopper FSP-211 8’ Mounting Height Must specify Dimming Driver. *120V-277V Only (WSC-8) 8’ Mounting Height (WSC-20) 9-20’ Mounting Height (WSC-40) 21-40’ Mounting Height This option will require(1) FSIR 100 remote for programing Motion Sensor (MS-8) 8’ Mounting Height (MS-20) 9-20’ Mounting Height (MS-40) 21-40’ Mounting Height Options Fixture A B C Stripe Max. Watts Lbs. AME-2-L 19” 19” 12” 2” 238 W 29 AME-4-L 23” 23” 15” 2” 373 W 68 A B C The new American LED Luminaire from Visionaire combines contemporary design with new LED technology; while maintaining a traditional fixture image. The LEDs Performance and Life are maximized by the unique integral aluminum heat sink built into the door frame. Maintenance of the drivers is simplified by making them easily accessible and provided with quick wiring connections. 72, 144 or 224 LEDs are available in 350 or 530 mA rating providing up to 33,000 lumens. Six optical distribution patterns are available and feature a unique Type T-4A automotive pattern for the front row of auto dealerships. Choose between 3000, 4000 or 5000 Kelvin temperature of the LEDs. A durable Polyester powder coat finish is guaranteed for five years; and is available in standard or custom colors. The American LED series is an exceptional choice for auto dealerships, shopping centers, commercial parking lots and general parking area lighting. AR E A Project Name: Catalog Number: Type CAW-432 : UU3 AME-2-L T4 72LC 3 4K UNV BOA6 WH GC TO VERIFY ALL INFORMATION BELOW GC SEE NOTES BELOW 2020-160821 12/07/20 19645 Rancho Way Rancho Dominguez, CA 90220 Tel: (310) 512-6480 Fax: (310) 512-6486 www.visionairelighting.com 29 American LED EPA Data Fixture with Arm AME-2 2.2 4.0 4.4 6.0 5.1 7.1 2.6 AME-4 3.4 6.2 6.8 9.2 7.8 10.9 3.9 Housing • All housings are manufactured using advanced computerized numerical control (CNC) machinery. Precision sheared and formed from one-piece, corrosion-resistant aluminum, with tooled external reveal. • The computerized CNC machinery enables all American housings to be constructed quickly, efficiently and adhering to exacting ISO 9002 standards. All external hardware is stainless steel. Door Assembly • Removable hinged door assembly is CNC precision, sheared and formed from one- piece, corrosion-resistant aluminum with captive stainless steel fastener The LEDs and drivers are mounted to an aluminum heat sink that is attached to the door frame. Optical System • The LED light assemblies come with up to 224 LEDs. Six IES distribution patterns are offered as standard; with a unique Type 4 Automotive optic available for Dealerships. The optical system qualifies as IES full cutoff; to restrict light trespass, glare, and light pollution. Quali-Guard Finish • The finish is Quali-Guard textured, chemically pretreated through a multiple-stage washer, electrostatically applied, thermoset polyester powder coat finish, with a minimum of 3-5 millimeter thickness. Finish is oven-baked at 400ºF to promote maximum adherence and finish hardness. All finishes are available in standard and custom colors Mounting • A rounded extruded aluminum, Bolt-On Arm (BOA), with an in-pole nut plate, securing (2) inch zinc running bolts with stainless steel hardware is standard. A Round Pole Plate Adaptor (RPP) is required for mounting to 3” - 5” round poles. Electrical Assembly • The American LED Series is supplied with a choice of 350 or 530 mA high- performance LED drivers that accept 120 v thru 480v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40°C operations. • 10 kV surge protector supplied as standard. Warranty • Five (5) year Limited Warranty on entire system, including finish. For full warranty information, visit www.visionairelighting.com Options • Photocell & Receptacle • Photo receptacle • Button type photocell • House side light shield • Round pole plate adaptor • Dimming Driver • Wireless Controls • Motion Sensor Please consult factory for custom options. Listings • American is ETL listed, suitable for wet locations • IP65 Rated • LM79 and LM80. • EISA compliant. • RoHS compliant • Powder Coated Tough™ • DLC Listed AR E A DesignLights Consortium (DLC) qualified Product. Some configurations of this product family may not be DesignLights Consortium (DLC) listed, please refer to the DLC qualified products list to confirm listed configurations. http://www.designlights.org/ American 5K LED LUMEN DATA # of LEDs mA Type 2 B U G Type 3 B U G Type 4 B U G Type 4A B U G Type 5 B U G Type 5W B U G Watts 72 350 8,470 2 0 2 7,485 2 0 2 8,401 2 0 2 8,069 1 0 1 9,174 3 0 1 9,145 3 0 1 80 530 11,883 3 0 3 10,501 2 0 2 11,786 2 0 2 11,321 2 0 1 12,871 3 0 1 12,830 3 0 1 120 144 350 16,423 3 0 3 14,513 3 0 3 16,289 2 0 3 15,656 2 0 1 17,789 4 0 1 17,732 4 0 2 160 530 21,913 3 0 3 19,365 3 0 3 21,734 3 0 3 20,876 2 0 2 23,736 4 0 2 25,249 4 0 2 238 224 350 24124 3 0 3 22443 3 0 3 24480 3 0 3 24322 2 0 2 26734 5 0 2 26285 5 0 2 246 530 32982 4 0 4 30683 3 0 3 33468 3 0 3 33252 3 0 2 36550 5 0 2 35935 5 0 2 377 Visit www.visionairelighting.com for up-to-the-minute chart information, including types not listed here. * For 4000K multiply values by 0.98 * For 3000K multiply values by 0.95 2020-160821 12/07/20 Dimensional Drawings For more detailed information on mounting, wiring or installation instructions, please consult factory. If poles are not ordered with fixtures, please specify mounting requirements. This document contains proprietary information of Visionaire Lighting  LLC. Any use of this information requires the written approval of Visionaire Lighting, LLC. In keeping with our TQM policy of continuous improvement, Visionaire reserves the right to change any specifications contained herein without prior notice. 28 American LED Model Optics Source Current Voltage Mounting Finish Bolt-On Arm 6” (BOA6) Bolt-On Arm 10” (BOA10) Knuckle Mount (KM) Wall Mount *Cast Wall Plate (BAWP) to be ordered separately (WM) Spider Mount Fits 2 3/8” O.D. (SM) Round Pole Plate Adaptors (RPP) are to be ordered separately. Bronze (BZ) Black (BK) Smooth Black (SBK) White (WH) Smooth White (SWH) Graphite (GP) Grey (GY) Silver Metallic (SL) Custom Color (CC) Kelvin 3000K *Warm white (3K) 4000K *Neutral white (4K) 5000K *Cool white (5K) 120-277 *Universal voltage (UNV) 480 (5) 347 (8) mA 350 (3) 530 (5) Type II (T2) Type III (T3) Type IV (T4) Type IV-A (T4A) Type V (T5) Type V-W (T5W) # of LEDs 72 (72LC) 144 (144LC) 224 (224LC) AME-2-L AME-4-L Photocell & Receptacle *Specify Voltage (PCR120) (PCR208) (PCR240) (PCR277) *Specify BOA or Spider Mount Photo & Receptacle with shorting cap (PER) *Specify BOA or Spider Mount Button Type Photocell *Specify Voltage (PC120) (PC208) (PC240) (PC277) House Side Light Shield (LS) Round Pole Plate Adapter (RPP) 0-10v Dimming Driver No Controls (DIM) Wireless Controls Consult Factory (WS) Motion Sensor/Control Watt Stopper FSP-211 8’ Mounting Height Must specify Dimming Driver. *120V-277V Only (WSC-8) 8’ Mounting Height (WSC-20) 9-20’ Mounting Height (WSC-40) 21-40’ Mounting Height This option will require(1) FSIR 100 remote for programing Motion Sensor (MS-8) 8’ Mounting Height (MS-20) 9-20’ Mounting Height (MS-40) 21-40’ Mounting Height Options Fixture A B C Stripe Max. Watts Lbs. AME-2-L 19” 19” 12” 2” 238 W 29 AME-4-L 23” 23” 15” 2” 373 W 68 A B C The new American LED Luminaire from Visionaire combines contemporary design with new LED technology; while maintaining a traditional fixture image. The LEDs Performance and Life are maximized by the unique integral aluminum heat sink built into the door frame. Maintenance of the drivers is simplified by making them easily accessible and provided with quick wiring connections. 72, 144 or 224 LEDs are available in 350 or 530 mA rating providing up to 33,000 lumens. Six optical distribution patterns are available and feature a unique Type T-4A automotive pattern for the front row of auto dealerships. Choose between 3000, 4000 or 5000 Kelvin temperature of the LEDs. A durable Polyester powder coat finish is guaranteed for five years; and is available in standard or custom colors. The American LED series is an exceptional choice for auto dealerships, shopping centers, commercial parking lots and general parking area lighting. AR E A Project Name: Catalog Number: Type CAW-432 : UU4 AME-2-L T5 144LC 5 4K UNV BOA6 WH GC TO VERIFY ALL INFORMATION BELOW GC SEE NOTES BELOW 2020-160821 12/07/20 19645 Rancho Way Rancho Dominguez, CA 90220 Tel: (310) 512-6480 Fax: (310) 512-6486 www.visionairelighting.com 29 American LED EPA Data Fixture with Arm AME-2 2.2 4.0 4.4 6.0 5.1 7.1 2.6 AME-4 3.4 6.2 6.8 9.2 7.8 10.9 3.9 Housing • All housings are manufactured using advanced computerized numerical control (CNC) machinery. Precision sheared and formed from one-piece, corrosion-resistant aluminum, with tooled external reveal. • The computerized CNC machinery enables all American housings to be constructed quickly, efficiently and adhering to exacting ISO 9002 standards. All external hardware is stainless steel. Door Assembly • Removable hinged door assembly is CNC precision, sheared and formed from one- piece, corrosion-resistant aluminum with captive stainless steel fastener The LEDs and drivers are mounted to an aluminum heat sink that is attached to the door frame. Optical System • The LED light assemblies come with up to 224 LEDs. Six IES distribution patterns are offered as standard; with a unique Type 4 Automotive optic available for Dealerships. The optical system qualifies as IES full cutoff; to restrict light trespass, glare, and light pollution. Quali-Guard Finish • The finish is Quali-Guard textured, chemically pretreated through a multiple-stage washer, electrostatically applied, thermoset polyester powder coat finish, with a minimum of 3-5 millimeter thickness. Finish is oven-baked at 400ºF to promote maximum adherence and finish hardness. All finishes are available in standard and custom colors Mounting • A rounded extruded aluminum, Bolt-On Arm (BOA), with an in-pole nut plate, securing (2) inch zinc running bolts with stainless steel hardware is standard. A Round Pole Plate Adaptor (RPP) is required for mounting to 3” - 5” round poles. Electrical Assembly • The American LED Series is supplied with a choice of 350 or 530 mA high- performance LED drivers that accept 120 v thru 480v, 50 Hz to 60 Hz, input. Power factor of 90%. Rated for -40°C operations. • 10 kV surge protector supplied as standard. Warranty • Five (5) year Limited Warranty on entire system, including finish. For full warranty information, visit www.visionairelighting.com Options • Photocell & Receptacle • Photo receptacle • Button type photocell • House side light shield • Round pole plate adaptor • Dimming Driver • Wireless Controls • Motion Sensor Please consult factory for custom options. Listings • American is ETL listed, suitable for wet locations • IP65 Rated • LM79 and LM80. • EISA compliant. • RoHS compliant • Powder Coated Tough™ • DLC Listed AR E A DesignLights Consortium (DLC) qualified Product. Some configurations of this product family may not be DesignLights Consortium (DLC) listed, please refer to the DLC qualified products list to confirm listed configurations. http://www.designlights.org/ American 5K LED LUMEN DATA # of LEDs mA Type 2 B U G Type 3 B U G Type 4 B U G Type 4A B U G Type 5 B U G Type 5W B U G Watts 72 350 8,470 2 0 2 7,485 2 0 2 8,401 2 0 2 8,069 1 0 1 9,174 3 0 1 9,145 3 0 1 80 530 11,883 3 0 3 10,501 2 0 2 11,786 2 0 2 11,321 2 0 1 12,871 3 0 1 12,830 3 0 1 120 144 350 16,423 3 0 3 14,513 3 0 3 16,289 2 0 3 15,656 2 0 1 17,789 4 0 1 17,732 4 0 2 160 530 21,913 3 0 3 19,365 3 0 3 21,734 3 0 3 20,876 2 0 2 23,736 4 0 2 25,249 4 0 2 238 224 350 24124 3 0 3 22443 3 0 3 24480 3 0 3 24322 2 0 2 26734 5 0 2 26285 5 0 2 246 530 32982 4 0 4 30683 3 0 3 33468 3 0 3 33252 3 0 2 36550 5 0 2 35935 5 0 2 377 Visit www.visionairelighting.com for up-to-the-minute chart information, including types not listed here. * For 4000K multiply values by 0.98 * For 3000K multiply values by 0.95 2020-160821 12/07/20 14 ' - " 4 6 ' - " 0 125 910 16041 KK/MF 3/9/2020 "0 B of A Lighting ( CAW-432 ) - SANTA ANA , CALIFORNIA 95#5 MA X P O L E H E I G H T 2,500 , MAX WATER/CEMENT RATIO = 0.5 ANCHOR BOLTS SEE A/- 0 BASE PLATE SEE A/- ASTM A36 9"x9"x0.75" BASE PL W/(4) 3/4" DIA. MIN X 24" MIN EMBED GR 36 MIN ANCHOR BOLTS 9.1875" CIRCULAR BOLT THE ASSUMED ALLOWABLE BEARING PRESSURE IS 1500 PSF AND ALLOWABLE LATERAL BEARING PRESSURE IS 100 PSF PER FOOT PER CBC 2019 TABLE 1806.2 WITH SITE CLASS D. THIS DETAIL IS NOT APPLICABLE AT MUD, ORGANIC SILT, ORGANIC CLAYS, PEAT OR UNPREPARED FILL UNLESS DEEMED ACCEPTABLE BY THE LOCAL CODE OFFICIAL. 1"MIN, TYP 1 " M I N , LIGHT POLE PER MFR HSS 4"x4"x0.18" MIN ASTM A500 GR 46 OR HSS 4"DIA. x0.18" MIN ASTM A500 GR 46 LIGHT PER MFR, WT = 55 LBS MAX, PROJECTED WIND AREA =2.00 SQ FT MAX THE FOOTING IS DESIGNED PER CBC 2019 SECTION 1807 AND ASCE 7-16 Date Signed: 03/13/2020 2020-160821 12/07/20 STRUCTURAL CALCULATIONS B of A CAW-432 2880 N. Main St. Santa Ana, CA prepared for Rogers Electric 1506 West Whispering Wind Dr. Suite 125 Phoenix, AZ, 85085 prepared by John A. Martin & Associates, Inc. 950 South Grand Avenue, Suite 400 Los Angeles, California 90015 213.483.6490 JAMA Project No. 16041 Date 3/09/20 950 SOUTH GRAND AVENUE, 4TH FLOOR | LOS ANGELES, CA 90015 | 213.483.6490 T | 213.483.3084 F | WWW.JOHNMARTIN.COM Date Signed: 03/13/2020 2020-160821 12/07/20 3/9/2020 ATC Hazards by Location https://hazards.atcouncil.org/#/wind?lat=33.7599604&lng=-117.867572&address=2880 N Main St%2C Santa Ana%2C CA 92701%2C USA 1/2 Hazards by Location Search Information Address: 2880 N Main St, Santa Ana, CA 92701, USA Coordinates: 33.7599604, -117.867572 Elevation: 137 ft Timestamp: 2020-03-09T13:50:34.553Z Hazard Type: Wind ASCE 7-16 MRI 10-Year 66 mph MRI 25-Year 71 mph MRI 50-Year 77 mph MRI 100-Year 81 mph Risk Category I 89 mph Risk Category II 95 mph Risk Category III 102 mph Risk Category IV 106 mph ASCE 7-10 MRI 10-Year 72 mph MRI 25-Year 79 mph MRI 50-Year 85 mph MRI 100-Year 91 mph Risk Category I 100 mph Risk Category II 110 mph Risk Category III-IV 115 mph ASCE 7-05 ASCE 7-05 Wind Speed 85 mph The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area – in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. Mountainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the 137 ft Map data ©2020 Google, INEGI Report a map error 2020-160821 12/07/20 3/9/2020 ATC Hazards by Location https://hazards.atcouncil.org/#/seismic?lat=33.7599604&lng=-117.867572&address=2880 N Main St%2C Santa Ana%2C CA 92701%2C USA 1/2 Hazards by Location Search Information Address: 2880 N Main St, Santa Ana, CA 92701, USA Coordinates: 33.7599604, -117.867572 Elevation: 137 ft Timestamp: 2020-03-09T13:49:58.914Z Hazard Type: Seismic Reference Document: ASCE7-16 Risk Category: II Site Class: D-default Basic Parameters Name Value Description SS 1.311 MCE R ground motion (period=0.2s) S1 0.467 MCE R ground motion (period=1.0s) SMS 1.573 Site-modified spectral acceleration value SM1 * null Site-modified spectral acceleration value SDS 1.048 Numeric seismic design value at 0.2s SA SD1 * null Numeric seismic design value at 1.0s SA * See Section 11.4.8 Additional Information Name Value Description SDC * null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv * null Site amplification factor at 1.0s CRS 0.93 Coefficient of risk (0.2s) CR1 0.925 Coefficient of risk (1.0s) PGA 0.552 MCE G peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.663 Site modified peak ground acceleration 137 ft Map data ©2020 Google, INEGI Report a map error 2020-160821 12/07/20 3/9/2020 ATC Hazards by Location https://hazards.atcouncil.org/#/seismic?lat=33.7599604&lng=-117.867572&address=2880 N Main St%2C Santa Ana%2C CA 92701%2C USA 2/2 TL 8 Long-period transition period (s) SsRT 1.311 Probabilistic risk-targeted ground motion (0.2s) SsUH 1.409 Factored uniform-hazard spectral acceleration (2% probability of exceedance in 50 years) SsD 1.521 Factored deterministic acceleration value (0.2s) S1RT 0.467 Probabilistic risk-targeted ground motion (1.0s) S1UH 0.505 Factored uniform-hazard spectral acceleration (2% probability of exceedance in 50 years) S1D 0.6 Factored deterministic acceleration value (1.0s) PGAd 0.631 Factored deterministic acceleration value (PGA) * See Section 11.4.8 The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. 2020-160821 12/07/20 1 of 2 JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS Client: Sheet Project: Job No 16041 Date 3/9/2020 Engineer KK/MF Wind Analysis (ASCE 7-16 Chapter 29) F = qzGCfA qz = 0.00256KzKztKdKeV2 Kzt= 1 Fig. 26.8-1 (Not applicable at high elevation, escarpment, ridge, or hill/mountain) Kd = 0.9 Table 26.6-1 Ke 1 Table 26.9-1 Kz Table 26.10 V = 95 mph Exp C H = 14 ft (max) G Section 26.11 Cf Figure 29.4-1 Pole centroid (ft) Kz qz (psf) Cf G Length (ft) Width (in) Area (ft2) 0-3 ft conc. Base 1.5 0.85 17.7 2 0.85 3.0 24 6.00 3-15 ft 8.5 0.85 17.7 2 0.85 11.0 5 4.58 15-20 ft 0 0.9 18.7 2 0.85 0.0 5 0.00 20-25 ft 0 0.94 19.5 2 0.85 0.0 5 0.00 25-30 ft 0 0.964 20.0 2 0.85 0.0 5 0.00 (G Type) OSQ-A-NM 14 0.98 20.4 2 0.85 2.00 (ASD) Forces at finished grade Frost Depth = 0 ft (for areas not adjacent heated spaces) Pole F (lbs) Mo (ft-lb) 0-3 ft Concrete Base 108.2 162 3-15 ft 82.6 702 15-20 ft 0.0 0 20-25 ft 0.0 0 25-28 ft 0.0 0 (G Type) OSQ-A-NM 41.6 582 Sum = 232 1447 Heq = Mo/F = 6.2 ft Forces at pole base Pole centroid (ft) F (lbs) Mo (ft-lb) 3-15 ft 5.5 137.7 757 15-20 ft -3 0.0 0 20-25 ft -3 0.0 0 25-28 ft -3 0.0 0 OSQ-A-NM Series 11 69.3 762 Sum = 207 1520 ASD Forces at pole Base = 125 910 Rogers Electric CBC 2019 CAW-432 SANTA ANA, CALIFORNIA 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\0.Source Calcs\Automated Light Pole Foundation ASCE 7-16 200124.xlsm 2020-160821 12/07/20 2 of 2 JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS Client: Sheet Project: Job No 16041 Date 3/9/2020 Engineer KK/MF Rogers Electric CBC 2019 CAW-432 SANTA ANA, CALIFORNIA Seismic (ASCE 7-16 Chapter 13) Fp = 0.4apSdsIpWp(1+2z/h)/Rp ASCE Table 13.6-1: Light Fixture Fp min = 0.3SdsIpWp ap = 1 Sds = 1.048 Rp = 1.5 Ip = 1 z/h = 0 Fp = 0.4apSdsIpWp(1+2z/h)/Rp = 0.28 /Wp Fp min = 0.3SdsIpWp = 0.31 /Wp Control centroid (ft) Wp (lbs) Fp (lbs) Mo (ft-lb) Pole 7 183 58 403 (G Type) OSQ-A-NM 14 55 17 242 Sum = 238 75 645 WIND GOVERNS Foundation (CBC 2019 section 1807.3.2.1 Nonconstrained) d^ = A/2(1+(1+4.36Heq/A)1/2) Bearing Pressure = WT/Ftg area S1 = 1/3*(L)*(d^) WT = 238 lbs 2 ft Ftg Area = 3.14 ft2 3.47 ft (TRIAL) Bearing Pressure = 76 psf 6.2 ft Bearing Pressure Allow = 1500 psf 232 lbs 200 lbs/sq/ft/ft S1 = 231 A = 1.17 d^ = 3.47 ft (ACTUAL) d^actual - d^trial = 0.00 OK A = 2.34P/(S1b) b = d^ = Heq = Distance from ground surface to point of application 'P" P = Applied lateral force S1 = (L) = Allowable lateral soil-bearing pressure USE Min Footing Depth = 4.50 ft Diameter of round post or footing or diagonal dimension of square post or footing Depth of embedment in earth but not over 12 feet for purpose of computing lateral pressure Allowable lateral soil-bearing pressure based on a depth of one-third the depth of embedment Heq = Pasd (P) = Lateral Bearing# (L) # Lateral Bearing may equal two times the value of Table 1806.2 per section 1806.3.4 CBC 2019 ftg depth (d^) = ftg diameter (b) = 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\0.Source Calcs\Automated Light Pole Foundation ASCE 7-16 200124.xlsm 2020-160821 12/07/20 1 of 1 JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS Client: Sheet Project: Job No 16041 Date 3/9/2020 Engineer KK/MF Light pole analysis Square pole d = 4 in bf = 4 in t = 0.18 in Fy = 46 ksi d1 = d - 2t = 3.64 in b1 = b - 2t = 3.64 in Zx = bd2/4 - (b-2t)(d-2t)2/4 = 3.94 in3 Round Pole d = 4 in t = 0.18 in Fy = 46 ksi d1 = d - 2t = 3.64 in Zx = d 3 /6-d1 3/6 = 2.63 in3 Light Pole Bending Capacity Zx,min = 2.63 in3 Fy = 46 ksi φMn = 0.9FyZx = 9069 lb-ft > Mu = 1520 ok DCR = 0.17 Rogers Electric CBC 2019 CAW-432 SANTA ANA, CALIFORNIA 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\0.Source Calcs\Automated Light Pole Foundation ASCE 7-16 200124.xlsm 2020-160821 12/07/20 1 of 1 JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS Client: Sheet Project: Job No 16041 Date 3/9/2020 Engineer KK/MF Base Plate Analysis N = 9 in Minimum 9" Square Plate x 3/4" Thick B = 9 in tp = 0.75 in Fy = 36 ksi f = N/2 = 4.5 in f'c = 2500 psi fp,max = 1381 psi qmax = 12431 lbs/in Mr = 1520 lb-ft Pr = 238 lbs e = Mr/Pr = 77 in > ecrit = N/2 - Pr/2/qmax 4.5 in Design of Column Base Plates with Large Moment (Design Guide 1) Y = (f+N/2) - ((f+N/2)2- 2Pr(e+f)/qmax)1/2 = 0.2 in Tu = qY-Pu = 1928 lbs Y < m = 2.60 in Bearing Interface: m = (N-0.95d)/2 = 2.60 in tp,req = 2.11(fpY(m-Y/2)/Fy)1/2 = 0.27 in Tension Interface: x = N/2-d/2-1 = 1.50 in tp,req = 2.11(Tux/B/Fy)1/2 = 0.20 in tp = 0.75 in > tp,req = 0.27 in OK DCR = 0.36 Anchor Bolts Minimum (4) 3/4" Dia. x 24" Anchor Bolts Wind Forces on Anchors= Seismic Forces on Anchors= Vu = 207 lbs ΩVu = 78 lbs Mu = 1520 lb-ft ΩMu = 1052 lb-ft *Wind governs anchorage analaysis. See attached Hilti Profis Report for anchorage analysis. Forces per bolt = d = 6.95 in Tu,bolt = Mu/d = 1313 lbs φTn = 6412 lbs DCR = 0.20 Vu,bolt = Vu/4 = 52 lbs φVn = 1468 lbs DCR = 0.04 DCR = (Tu/Tn)5/3 + (Vu/Vn)5/3 = 0.07 ok Rogers Electric CBC 2019 CAW-432 SANTA ANA, CALIFORNIA 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\0.Source Calcs\Automated Light Pole Foundation ASCE 7-16 200124.xlsm 2020-160821 12/07/20 P (kip) Mx (k-ft) 1200 -200 250-250 fs=0.5fy fs=0 fs=0.5fy fs=0 (Pmax)(Pmax) (Pmin)(Pmin) fs=0.5fy fs=0 fs=0.5fy fs=0 1 2020-160821 12/07/20 2020-160821 12/07/20 www.hilti.us Profis Anchor 2.7.5 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Company: Specifier: Address: Phone I Fax: E-Mail: | Page: Project: Sub-Project I Pos. No.: Date: 1 6/27/2019 Specifier's comments: 1 Input data Anchor type and diameter: Hex Head ASTM F 1554 GR. 36 3/4 Effective embedment depth: hef = 24.000 in. Material: ASTM F 1554 Proof: Design method ACI 318-14 / CIP Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in. Anchor plate: lx x ly x t = 9.000 in. x 9.000 in. x 0.500 in.; (Recommended plate thickness: not calculated Profile: Square HSS (AISC); (L x W x T) = 4.000 in. x 4.000 in. x 0.125 in. Base material: cracked concrete, 2500, fc' = 2500 psi; h = 48.000 in. Reinforcement: tension: condition A, shear: condition A; edge reinforcement: none or < No. 4 bar Geometry [in.] & Loading [lb, in.lb] HILTI DOES NOT HAVE A ROUND CONCRETE BASE PROFILE. A SQUARE WITH 7.406" MAINTAINS THE SAME CRITICAL EDGE DISTANCE. ANALYSIS FOR ANCHOR CAPACITY ONLY. SEE CALCULATIONS FOR DEMANDS AND DEMAND/CAPACITY RATIOS FOR THIS SITE. 2020-160821 12/07/20 www.hilti.us Profis Anchor 2.7.5 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Company: Specifier: Address: Phone I Fax: E-Mail: | Page: Project: Sub-Project I Pos. No.: Date: 2 6/27/2019 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity bbbbN / bbbb V [%] Status Tension Concrete Breakout Strength 12759 12823 100 / - OK Shear Concrete edge failure in direction x+ 1000 5871 - / 18 OK Loading bbbbN bbbbV z z z z Utilization bbbbN,V [%] Status Combined tension and shear loads 0.995 0.170 1.0 98 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Shear Capacity per bolt = 5871#/4 = 1468# Tension capacity per bolt = 12823#/2 = 6412# 2020-160821 12/07/20 N EXTERIOR LIGHTING PROGRAM VICINITY MAP âBank of America CALIFORNIA ATM LIGHTING REQUIREMENTS: CALIFORNIA FINANCE CODE SECTIONS 13000-13070 www.gmr1.com Office: (972) 771-6038 1629 Smirl Drive, Suite 200, Heath, Texas 75032 2880 N Main St Santa Ana, CA 92705 DRAWING INDEX: - LU-1 LU-2 LU-3 LU-4 E-0 E-1 E-2 E-3 COVER SHEET GENERAL NOTES LUMINAIRE SCHEDULE FULL SITE PHOTOMETRICS PLAN AT GRADE LANDSCAPING PLAN GENERAL NOTES & SCHEDULES SITE PLAN - LIGHTING TITLE 24 DOCUMENTS TITLE 24 DOCUMENTS CAW-432 2880 N. Main St. Santa Ana, CA v3 200605 SCOPE OF WORK: APN NUMBER: 002-222-01 11 7 2 1 1 REPLACE EXISTING FIXTURE REMOVE AND PATCH ADD NEW POLE AND FIXTURE ADD NEW FIXTURE OUT OF SCOPE - - - - - PLANS DESIGNED TO CALIFORNIA LEGISLATIVE 13040 & 13041 ATM LIGHTING STANDARDS. DUE TO CRITERIA OF ATM STANDARDS, LOCAL JURISDICTION LIGHTING CODE MAY NOT BE MET. 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 2020-160821 12/07/20 âBank of America E-0 GENERAL NOTES & SCHEDULES Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CAW-432 · · Main Place Op CAW-432 2880 N. Main St. Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE Job No.Date 20099-CAW-43207/13/2020 LUMINAIRE SCHEDULE **SEE FIXTURE CLARIFICATION NOTE #9 (NP) = NEW POLE (CBO) CONTROLLED BY OTHERS SYMBOL QTY LABEL FIXTURE ARRANGEMENT TOTAL FIXTURE COUNT NEW POLE COUNT FIXTURE TYPE / MOUNTING / MANUFACTURER BUG RATING MOUNTING HEIGHT MOUNTING ACCESSORIES 3 BO1 SINGLE (BO) CPY250-A-DM-F-20W-UL-WH-40K / CANOPY MOUNT / CREE MATCH EXISTING 1 BQ1 SINGLE (BQ) CPY250-B-DM-F-C-UL-WH-40K / CANOPY MOUNT / CREE MATCH EXISTING 1 SH1 SINGLE (SH) SEC-EDG-4M-WM-02-E-UL-BZ-350-40K / WALL MOUNT / CREE MATCH EXISTING 1 SH2 SINGLE (SH) SEC-EDG-4M-WM-02-E-UL-BZ-350-40K / WALL MOUNT / CREE 8' AFG 1 UU1 DOUBLE (2@180°) AME-2-L-T4-144LC-5-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE MATCH EXISTING 2 UU2 (NEW POLE) SINGLE AME-2-L-T2-72LC-5-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE 14' AFG 1 UU3 SINGLE AME-2-L-T4-72LC-3-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE MATCH EXISTING 1 UU4 SINGLE AME-2-L-T5-144LC-5-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE MATCH EXISTING 1 UU5 DOUBLE (2@180°) AME-2-L-T4-72LC-3-4K-UNV-BOA6-WH / POLE MOUNT / VISIONARE MATCH EXISTING 2 RC1 SINGLE EXISTING FLOOD FIXTURE - 4 RE1 SINGLE EXISTING CANOPY FIXTURE - 1 RI1 SINGLE EXISTING WALL FIXTURE - 1 YA1 SINGLE EXISTING POLE FIXTURE - ** CONTRACTOR TO VERIFY MOUNTING ACCESSORIES BEFORE ORDERING** 3 1 1 1 2 2 1 1 2 2 4 1 1 - - - - - 2 - - - - - - - B1-U0-G1 B2-U0-G1 B1-U0-G1 B1-U0-G1 B3-U0-G4 B3-U0-G3 B2-U0-G2 B4-U0-G2 B2-U0-G2 - - - - XA-BXCC9001 XA-BXCC9001 - - - - - - - - - - - TOTAL FIXTURE WATTAGE EXISTING FIXTURE WATTAGE BEING REMOVED/REPLACED 77 400 - 100 - 100 - 100 - - 115 - 77 400 229 400 20 100 31 100 25 100 25 - 229 400 2020-160821 12/07/20 2020-160821 12/07/20 âBank of America Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CAW-432 E-2 TITLE 24 DOCUMENTS Main Place Op CAW-432 2880 N. Main St. Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE Job No.Date 20099-CAW-43207/13/2020 2020-160821 12/07/20 âBank of America Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CAW-432 E-3 TITLE 24 DOCUMENTS Main Place Op CAW-432 2880 N. Main St. Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE Job No.Date 20099-CAW-43207/13/2020 2020-160821 12/07/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSION Page 1 of 8 CERTIFICATE OF COMPLIANCE NRCC-LTO-E This document is used to demonstrate compliance with requirements in §110.9, §130.0, §130.2, §140.7, and §141.0(b)2L for outdoor lighting scopes using the prescriptive path. Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 A. GENERAL INFORMATION 01 Project Location (city) Santa Ana 04 Total Illuminated Hardscape Area (ft2) 26,953 02 Climate Zone 8 03 Outdoor Lighting Zone per Title 24, Part 1 §10-114 or as designated by Authority Having Jurisdiction (AHJ): LZ-0: Very Low - Undeveloped Parkland LZ-2: Moderate - Rural Areas LZ-4: High - Must be reviewed by CA Energy Commission for Approval LZ-1: Low - Developed Parkland LZ-3: Moderately High - Urban Areas✔ B. PROJECT SCOPE Table Instructions: Include any outdoor lighting systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in §140.7 or §141.0(b)2L for alterations. My project consists of: 01 02 New Lighting System Must Comply with Allowances from §140.7. Altered Lighting System ✔ Is your alteration increasing the connected lighting load (Watts)? Yes No 03 04 05 % of Existing Luminaires Being Altered¹ Sum Total of Luminaires Being Added or Altered Calculation Method ≥ 10% and < 50% ≥ 50%✔ < 10% 15 Calculated Allowance per §140.7 ¹ FOOTNOTES: % of Existing Luminaires Being Altered = (Sum Total of Luminaires Being Added or Altered / Existing Luminaires within the Scope of the Permit Application) x 100 C. COMPLIANCE RESULTS Table Instructions: If any cell on this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. for guidance. Calculation of Total Allowed Lighting Power (Watts) §140.7 or §141.0(b)2L 01 02 03 04 05 06 General Hardscape Allowance §140.7(d)1 + Per Application §140.7(d)2 + Sales Frontage §140.7(d)2 + Ornamental §140.7(d)2 + Per Specific Area §140.7(d)2 OR Existing Power §141.0(b)2L = (See Table I) (See Table J) (See Table K) (See Table L) (See Table M) (See Table N) Compliance Results 07 08 09 Total Allowed (Watts) ≥ Total Actual (Watts) 07 Must be ≥ 08 (See Table F) 673.825 + 135 + + 350.389 + 269.53 OR = 1,428.744 ≥ 1,289 COMPLIES Cutoff Compliance (See Table G for Details) Not Applicable Controls Compliance (See Table H for Details) COMPLIES with Exceptional Conditions 2020-160821 12/07/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 2 of 8 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 D. EXCEPTIONAL CONDITIONS This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. Table F. Outdoor Lighting Fixture Schedule Permit Applicant Notes: UU1: Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). UU2: Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). UU3: Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). UU4: Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). UU5: Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). Table H. Outdoor Lighting Controls Permit Applicant Notes: Parking Lot: Lighting is required for compliance to California Finance Code Section 13000-13070 for footcandle requirements for ATM's. Dimming fixtures would lower footcandles to below minimum requirements. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. F. OUTDOOR LIGHTING FIXTURE SCHEDULE Table Instructions: For new or altered lighting systems demonstrating compliance with §140.7 (ie Table I has expanded for input), include all luminaires being installed and any existing luminaires remaining or being moved within the spaces covered by the permit application in the Table below. For altered lighting systems using the Existing Power method per §141.0(b)2L (ie Table N has expanded for input), include only new luminaires being installed and replacement luminaires being installed as part of the project scope (ie, do not include existing luminaires remaining or existing luminaires being moved). Designed Wattage: 01 Name or Item Tag 02 Complete Luminaire Description 03 Watts per luminaire1,2 04 How Wattage is determined 05 Total number luminaires² 06 Luminaire Status³ 07 Excluded per §140.7(a) 08 Design Watts 09 Cutoff Req. ≥ 6,200 initial lumen output §130.2(b)⁴ 10 Field Inspector Pass Fail B01 Canopy Mount Fixture Linear 20 Mfr. Spec¹ 3 Altered 60 NA: <6,200 lumens BQ1 Canopy Mount Fixture Linear 31 Mfr. Spec¹ 1 Altered 31 NA: <6,200 lumens SH1 Wall Mount Fixture Linear 25 Mfr. Spec¹ 1 Altered 25 NA: <6,200 lumens SH2 Wall Mount Fixture Linear 25 Mfr. Spec¹ 1 New 25 NA: <6,200 lumens UU1 Pole Mount Fixture Linear 229 Mfr. Spec¹ 2 Altered 458 Exempt* Table Continued 2020-160821 12/07/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 3 of 8 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 01 Name or Item Tag 02 Complete Luminaire Description 03 Watts per luminaire1,2 04 How Wattage is determined 05 Total number luminaires² 06 Luminaire Status³ 07 Excluded per §140.7(a) 08 Design Watts 09 Cutoff Req. ≥ 6,200 initial lumen output §130.2(b)⁴ 10 Field Inspector Pass Fail UU2 Pole Mount Fixture Linear 115 Mfr. Spec¹ 2 New 230 Exempt* UU3 Pole Mount Fixture Linear 77 Mfr. Spec¹ 1 Altered 77 Exempt* UU4 Pole Mount Fixture Linear 229 Mfr. Spec¹ 1 Altered 229 Exempt* UU5 Pole Mount Fixture Linear 77 Mfr. Spec¹ 2 Altered 154 Exempt* Total Designed Watts: 1,289 * NOTES: Selections with a * require a note in the space below explaining how compliance is achieved. EX: Luminaire is lighting a statue; EXCEPTION 2 to §130.2(b). UU1 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). UU2 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). UU3 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). UU4 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). UU5 Fixture is necessary for compliance with AB 244, banking security law; EXEMPTION 3 to 130.2(b). ¹ FOOTNOTES: Authority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per §130.0(c) ² For linear luminaires, wattage should be indicated as W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 05 instead of number of luminaires. ³ Select “New” for new luminaires in a new outdoor lighting project or for added luminaires in an alteration. Select “Altered” for replacement luminaires in an alteration. Select “Existing to Remain” for existing luminaires within the project scope that are not being altered and are remaining. Select “Existing Reinstalled” for existing luminaires which are being removed and reinstalled as part of the project scope ⁴ Compliance with mandatory cutoff requirements is required for luminaires with initial lumen output ≥ 6,200 unless exempted by §130.2(b). G. CUTOFF REQUIREMENTS (BUG) This Section Does Not Apply H. OUTDOOR LIGHTING CONTROLS 2020-160821 12/07/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 4 of 8 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 Table Instructions: Complete this table demonstrating compliance with controls requirements for all new or altered luminaires installed as part of the permit application. For alteration projects, luminaires which are existing to remain (ie untouched) and luminaires which are removed and reinstalled (wiring only) do not need to be included in this table even if they are within the spaces covered by the permit application. When an option having a * is selected, the notes section of this table must be completed. The lighting controls section of the Compliance Summary Table on the first page will show "DOES NOT COMPLY" if the notes are left blank. For each requirement in columns 02 through 04, do not leave the field blank, instead select NA or Exempt* from the dropdown list to indicate not applicable or an exemption. Mandatory Controls 01 Area Description 02 Shut-Off §130.2(c)1 03 Auto-Schedule §130.2(c)2 04 Motion Sensor §130.2(c)3 05 Field Inspector Pass Fail Parking Lot Photocontrol Yes - EMCS Exempt * *NOTES: Controls with a * require a note in the space below explaining how compliance is achieved. EX: Not permitted by health & safety to be turned off; EXCEPTION 1 to §130.2(c). Parking Lot Lighting is required for compliance to California Finance Code Section 13000-13070 for footcandle requirements for ATM's. Dimming fixtures would lower footcandles to below minimum requirements. I. LIGHTING POWER ALLOWANCE (per §140.7) Table Instructions: Please complete this table for areas using the allowance calculations per §140.7. General Hardscape Allowance is per Table 140.7-A while "Use it or lost it" Allowances are per Table 140.7-B. Indicate which allowances are being used to expand sections for user input. Luminaires that qualify for one of the "Use it or lose it" allowances shall not qualify for another "Use it or lose it" allowance. 01 General Hardscape Allowance ✔ Per Application ✔ Sales Frontage Ornamental ✔ Per Specific Area✔ "Use it or lose it" Allowances (select all that apply) Table I (below) Table J Table K Table L Table M Calculated General Hardscape Lighting Power Allowance per Table 140.7-A (LZ 2 & 3) 02 04 05 06 Area Wattage Allowance (AWA) Area Description Illuminated Area (ft²) Allowed Density (W/ft²) Area Allowance (Watts) 03 Surface Type 07 08 09 Linear Wattage Allowance (LWA) Perimeter Length (lf) Allowed Density (W/lf) Linear Allowance (Watts) 10 Total General AWA + LWA (Watts) Sidewalk Concrete 0 0.03 0 0.4 0 0 Parking Area Asphalt 26,953 0.025 673.825 0.25 0 673.825 Table Continued 2020-160821 12/07/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 5 of 8 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 0 Initial Wattage Allowance for Entire Site (Watts): Total General Hardscape Allowance (Watts): 673.825 J. LIGHTING ALLOWANCE: PER APPLICATION Table Instructions: Please complete this table for areas using the wattage allowance per application from Table-140.7-B. 01 Area Description 02 Application per Table 140.7-B¹ 03 # of Locations Allowance per Location² (Watts) Extra Allowance (Watts) CALCULATED ALLOWANCE (Watts) 04 05 06 Luminaire Name or Item Tag DESIGN WATTS Watts per Luminaire³ 07 # of Luminaires³ 08 Design Watts 09 10 Additional Allowance (Watts) ATM Machine 2 100 135 B01 20 3 60 0 BQ1 31 1 31 0 SH1 25 1 25 0 SH2 25 1 25 Total Design Watts for this Area: 141 135 Total Allowance (Watts) All Areas: 135 ¹ FOOTNOTES: Primary entrance applications are only available for senior care facilities, healthcare facilities, police stations, hospitals, fire stations, and emergency vehicle facilities. ² The Allowance per Location for ATMs is 100W for the first ATM and 35W for each additional per Table 140.7-B. ³ For luminaires indicated in Table F as linear, wattage in column 07 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 08 instead of number of luminaires. K. LIGHTING ALLOWANCE: SALES FRONTAGE This Section Does Not Apply L. LIGHTING ALLOWANCE: ORNAMENTAL Table Instructions: Please complete this table for areas using the wattage allowance for Hardscape Ornamental Lighting from Table-140.7-B. Table Continued 2020-160821 12/07/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 6 of 8 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 01 Area Description 02 Illuminated Area (ft2) Allowed Density (W/ft2) Extra Allowance (Watts) CALCULATED ALLOWANCE (Watts) 03 04 05 Luminaire Name or Item Tag Watts per Luminaire1,2 # of Luminaires² DESIGN WATTS 06 07 Design Watts 08 09 Additional Allowance (Watts) Parking Lot 26,953 0.013 350.389 UU1 229 2 458 Total Design Watts for this Area: 458 350.389 Total Allowance (Watts) Ornamental: 350.389 ¹ FOOTNOTES: Luminaires qualifying for this allowance shall be rated < 100W and shall be post-top luminaires, lanterns, pendants or chandeliers. ² For luminaires indicated in Table F as linear, wattage in column 06 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 07 instead of number of luminaires. M. LIGHTING ALLOWANCE: PER SPECIFIC AREA Table Instructions: Please complete this table for areas using the wattage allowance per specific area type from Table 140.7-B. More than one specific area allowance may be taken in a single project, if applicable. However, multiple specific area allowances may not be taken for the exact same area on the site. 01 Area Description 02 Specific Area Type per Table 140.7-B 03 Specific Area (ft2)¹ Allowed Density (W/ft2) Extra Allowance (Watts) CALCULATED ALLOWANCE (Watts) 04 05 06 Luminaire Name or Item Tag Watts per Luminaire² # of Luminaires² DESIGN WATTS 07 08 09 Design Watts 10 Additional Allowance (Watts) Security Parking Lot Security for Retail Parking & Pedestrian Hardscape 26,953 0.01 269.53 UU2 115 2 230 0 UU3 77 1 77 Total Design Watts for this Area: 307 269.53 Total Allowance (Watts) All Areas: 269.53 Table Continued 2020-160821 12/07/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 7 of 8 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 ¹ FOOTNOTES: See Table 140.7-B for the rules for calculating the specific areas (ft²) for these additional lighting allowances. ² For luminaires indicated in Table F as linear, wattage in column 07 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 08 instead of number of luminaires. N. EXISTING CONDITIONS POWER ALLOWANCE (alterations only) This Section Does Not Apply ● ● O. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Table Instructions: Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https://www.energy.ca.gov/ title24/2019standards/2019_compliance_documents/Nonresidential_Documents/NRCI/ YES NO Form/Title Field Inspector Pass Fail NRCI-LTO-01-E - Must be submitted for all buildings. NRCI-LTO-02-E - Must be submitted for a lighting control system; or for an Energy Management Control System (EMCS), to be recognized for compliance. ● P. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE Table Instructions: Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and must be completed through an Acceptance Test Technician Certification Provider (ATTCP). For more information visit: http://www.energy.ca.gov/title24/attcp/providers.html YES NO Form/Title Field Inspector Pass Fail NRCA-LTO-02-A - Must be submitted for all outdoor lighting controls except for alterations where controls area added to ≤ 20 luminaires. 2020-160821 12/07/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSION Page 8 of 8 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2016 Exterior Lighting Program CAW-432 Report Page: Project Address: 2880 N. Main St. Date Prepared: 07/13/2020 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT Documentation Author Name: Jonathan D. Gentry Documentation Author Signature: Company: Craig L. Molnar Signature Date: 07/13/2020 Address: 10927 Crabapple Road CEA/ HERS Certification Identification (if applicable): City/State/Zip: Roswell, GA 30075 Phone: 770-992-5077 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Craig L. Molnar Responsible Designer Signature: Company : Craig L. Molnar Date Signed: 07/13/2020 Address: 10927 Crabapple Road License: E15519 City/State/Zip: Roswell, GA 30075 Phone: 770-992-5077 2020-160821 12/07/20