Loading...
HomeMy WebLinkAbout2906 S Halladay St - PlanMSP UM ACD 150'-10" 51 ' - 4 " 150'-10" 51 ' - 4 " 26'-7" 28 ' - 4" 84'-11" 4'-10" GAS SUBINV ACD ACD TNF 1 PROJECT DESCRIPTION: PLOT PLAN & VICINITY MAP SCALE: 1/16" = 1'PV-1 SCALE: NTS PV-1 PLOT PLAN & VICINITY MAP 19X355 LONGI SOLAR:LR4-60HPB 355M 355W MODULE ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 6.75KW DC STC,5.00 kW AC CEC REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV D02/14/2023 REV E02/16/2023 REV F02/20/2023 REV ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ARRAY LOCATIONS VICINITY MAP SCALE: NTSPV-1 2 HOUSE PHOTO EQUIPMENT SUMMARY 19 - LONGI SOLAR:LR4-60HPB 355M 355W MODULES 01 - SOLAREDGE TECHNOLOGY:SE9KUS (208V) INVERTER 19 - SOLAREDGE POWER OPTIMIZER S-440 PROJECT SITE SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8 OPTIMIZER CHART PV-9 EQUIPMENT ELEVATION PV-10+ EQUIPMENT SPECIFICATIONS 3 PAGE 1 OF 18 NOTES 1. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 2. MANUFACTURERS PRODUCT INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE AT THE TIME OF INSPECTION. 3. ALL SUBMITTALS WILL COMPLY WITH 2022 CEC, CBC, AND CFC. 4. SMOKE ALARMS AND CARBON MONOXIDE DETECTOR EQUIPMENT SHALL BE IN PLACE AT COMMERCIAL PROPERTY ACCORDING TO THE CCC, CBC R314-315 REQUIREMENT. AHJ - SANTA ANA UTILITY - SCE ACCOUNT # - CA-R-193387 PROPERTY LINE PR O P E RT Y L I N E PR O P ER T Y L I N E PROPERTY LINE 1-STORY HOUSE EXISTING DRIVEWAY (E)GATE (TYP.) (E)FENCEROOF #02 (11)LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #03 (05)LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #01 (03)LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF ACCESS POINT (E)MAIN SERVICE PANEL, 200A RATED, 240V (EXTERIOR) (E)UTILITY METER (N)AC DISCONNECT-1 (N)SOLAREDGE TECHNOLOGY : SE9KUS INVERTER INTEGRATED RAPID SHUTDOWN S H A L L A D A Y S T (E)GAS METER (E)DETACHED STRUCTURE (N)SUB PANEL, 200A RATED, 240V (INTERIOR) (N)SECONDARY FUSED AC DISCONNECT-3 (N)PRIMARY FUSED AC DISCONNECT-2 (INTERIOR) (N)TRANSFORMER 3-PHASE 240V DELTA-208 Y 120 (INTERIOR) GOVERNING CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA PLUMBING CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. Signed: 02/28/2023 Structural Only Bldg# 101112511 Approved: JLo Elec# 20177759 Approved: MSmith Issued 06/26/23 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE PAGE 6 OF 18 NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # LONGI SOLAR LR4-60HPB 355M 355 (355W)MODULES VMP 34.6 IMP 10.27 VOC 40.6 ISC 11.25 MODULE DIMENSION 69.09"L x 40.87"W x 1.50"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE TECHNOLOGY SE10KUS NOMINAL AC POWER 10.00KW NOMINAL OUTPUT VOLTAGE 208 VAC NOMINAL OUTPUT CURRENT 27.8A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2° AMBIENT TEMP (HIGH TEMP 2%)31° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 53° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%/°C EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 2 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1.00 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 17.58A 1.25 X 1.25 X MODULE ISC DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 38.40ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (17.58A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c)+22° EXPECTED WIRE TEMP (In Celsius)31 +22 = 53 TEMP. CORRECTION PER TABLE (310.16)0.76 NO. OF CURRENT CARRYING CONDUCTORS 2 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1.00 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.75A 1.25 X OPTIMIZER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 30.40ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO SUBPANEL: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 8AWG CIRCUIT CONDUCTOR AMPACITY 55A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 34.75A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 42.24ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (34.75A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM SUBPANEL TO MAIN SERVICE PANEL: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 250kcmil CIRCUIT CONDUCTOR AMPACITY 290A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 200.00A SUB-FEEDER BREAKER DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 222.72ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (200.00A) otherwise less the entry for circuit conductor size and ampacity 2906 S Halladay St - 2018139112/4/2023 MSP UM ACDGAS SUBINVACDACDTNF JB STRING LAYOUT REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV 1 STRING LAYOUT PV-3 SCALE: 3/16" = 1'-0" PAGE 3 OF 18 STRING 1 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 19 LONGI SOLAR LR4-60HPB 355M 355W MODULES INVERTER 01 SOLAREDGE TECHNOLOGY: SE10KUS (208V) INVERTER INTEGRATED RAPID SHUTDOWN OPTIMIZER 19 SOLAREDGE POWER OPTIMIZERS S-440 AC DISCONNECT 1 AC DISCONNECT EATON#DG222URB 60A, 2P, 240VAC NEMA 3R AC DISCONNECT 2 FUSED AC DISCONNECT-3 EATON#DG322NRB 60A, 3P, 240VAC NEMA 3R SUB PANEL 1 SUB PANEL, 200A RATED, 240V TRANSFORMER 1 15KVA TRANSFORMER 3-PHASE, 240V DELTA-208 Y 120 ATTACHMENT 50 CHIKOUSA COMPOSITION L-FOOT ATTACHMENT RAILS 6 CHIKO ASPHALT ROOF RACKING SYSTEM 134" RAILS 6 CHIKO ASPHALT ROOF RACKING SYSTEM 166" RAIL SPLICE 4 SPLICE KIT MID CLAMPS 24 MID CLAMPS END CLAMPS 28 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 7 GROUNDING LUG S H A L L A D A Y S T (E ) F R O N T O F CO M M E R C I A L B U I L D I N G (E ) B A C K O F CO M M E R C I A L B U I L D I N G 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV OPTIMIZER CHART 1-10 1 2 3 4 11-20 21-30 31-40 41-50 51-60 5 6 7 8 9 10 OPTIMIZER CHART PAGE 8 OF 18 S H A L L A D A Y S T 2906 S Halladay St - 2018139112/4/2023 10 ' - 0 " 10 ' - 0 " 10 ' - 0 " REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT ELEVATION PAGE 9 OF 18 EQUIPMENT ELEVATION SCALE: NTS 1 PV-9 (N) SUBPANEL, 200A RATED, 240V (INTERIOR) (N) SOLAREDGE TECHNOLOGY : SE10KUS INVERTER INTEGRATED RAPID SHUTDOWN (N) SECONDARY FUSED AC DISCONNECT-3 (E) UTILITY METER (E) MAIN SERVICE PANEL, 200A RATED, 240V (EXTERIOR) (N) PRIMARY FUSED AC DISCONNECT-2 (INTERIOR) (N) TRANSFORMER 3-PHASE 240V DELTA-208 Y 120 (INTERIOR) (N) AC DISCONNECT-1 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT SPECIFICATION PAGE 10 OF 18 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT SPECIFICATION PAGE 11 OF 18 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT SPECIFICATION PAGE 12 OF 18 2906 S Halladay St - 2018139112/4/2023 MSP UM ACD 150'-10" 51 ' - 4 " 150'-10" 51 ' - 4 " 26'-7" 28 ' - 4" 84'-11" 4'-10" GAS SUBINV ACD ACD TNF 1 PROJECT DESCRIPTION: PLOT PLAN & VICINITY MAP SCALE: 1/16" = 1'PV-1 SCALE: NTS PV-1 PLOT PLAN & VICINITY MAP 19X355 LONGI SOLAR:LR4-60HPB 355M 355W MODULE ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 6.75KW DC STC, 10.00 kW AC CEC REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV D02/14/2023 REV E02/16/2023 REV F02/20/2023 REV G09/15/2023 REV ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ARRAY LOCATIONS VICINITY MAP SCALE: NTSPV-1 2 HOUSE PHOTO EQUIPMENT SUMMARY 19 - LONGI SOLAR:LR4-60HPB 355M 355W MODULES 01 - SOLAREDGE TECHNOLOGY:SE10KUS (208V) INVERTER 19 - SOLAREDGE POWER OPTIMIZER S-440 PROJECT SITE SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8 OPTIMIZER CHART PV-9 EQUIPMENT ELEVATION PV-10+ EQUIPMENT SPECIFICATIONS 3 PAGE 1 OF 18 NOTES 1. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 2. MANUFACTURERS PRODUCT INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE AT THE TIME OF INSPECTION. 3. ALL SUBMITTALS WILL COMPLY WITH 2022 CEC, CBC, AND CFC. 4. SMOKE ALARMS AND CARBON MONOXIDE DETECTOR EQUIPMENT SHALL BE IN PLACE AT COMMERCIAL PROPERTY ACCORDING TO THE CCC, CBC R314-315 REQUIREMENT. 5. OCCUPANCY TYPE: R-3 6. CONSTRUCTION TYPE: VB AHJ - SANTA ANA UTILITY - SCE ACCOUNT # - CA-R-193387 PROPERTY LINE PR O P E RT Y L I N E PR O P ER T Y L I N E PROPERTY LINE 1-STORY HOUSE EXISTING DRIVEWAY (E) GATE (TYP.) (E) FENCEROOF #02 (11) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #03 (05) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #01 (03) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF ACCESS POINT (E) MAIN SERVICE PANEL, 200A RATED, 240V (EXTERIOR) (E) UTILITY METER (N) AC DISCONNECT-1 (N) SOLAREDGE TECHNOLOGY : SE10KUS INVERTER INTEGRATED RAPID SHUTDOWN S H A L L A D A Y S T (E) GAS METER (E) DETACHED STRUCTURE (N) SUB PANEL, 200A RATED, 240V (INTERIOR) (N) SECONDARY FUSED AC DISCONNECT-3 (N) PRIMARY FUSED AC DISCONNECT-2 (INTERIOR) (N) TRANSFORMER 3-PHASE 240V DELTA-208 Y 120 (INTERIOR) GOVERNING CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA PLUMBING CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. Structural Only Signed 9/29/2023 REVISION TO: Elec# 20177759 Issued 06/26/23 Elec# 20181391 Approved: MSmith Issued 12/04/23 2906 S Halladay St - 2018139112/4/2023 MSP UM ACD 3' - 5 " 13 ' - 1 0 " 7' - 0 " 8' - 0 " 8'-7"3" 11'-7" 4'-5" 5'-9" 1'-6" GAS SUBINVACDACDTNF JB REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV ROOF PLAN & MODULES ROOF DESCRIPTION ROOF TYPE COMP-SHINGLE ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 20° 182°2"x4"24" o.c. #2 20° 272° 2"x4" 24" o.c. #3 20° 92°2"x4"24" o.c. LEGEND - JUNCTION BOX MSP - MAIN SERVICE PANEL - VENTS, DISH (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT - UTILITY METER SCALE: 1/8" = 1'-0" - SOLAREDGE OPTIMIZER MODULE TYPE, DIMENSIONS & WEIGHT ACD - AC DISCONNECT - INVERTER 1 PV-2 NUMBER OF MODULES = 19 MODULES MODULE TYPE = LONGI SOLAR LR4-60HPB 355M 355W MODULES MODULE WEIGHT = 42.99 LBS / 19.5 KG. COMPONENT WEIGHT: 1.5 LBS. PER MODULE TOTAL DEAD LOAD: 845.31 LBS. POINT LOAD PER STANDOFF.: 845.31 LBS / 50 STANDOFF = 16.91 LBS MODULE DIMENSIONS = 69.09"x 40.87" = 19.61 SF UNIT WEIGHT OF ARRAY = 2.27 PSF UM JB INV ARRAY AREA WITH TOTAL ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 3 58.83 239.00 24.61 #2 11 215.71 488.60 44.15 #3 5 98.05 327.08 29.98 ROOF PLAN & MODULES PAGE 2 OF 18 ARRAY AREA WITH WHOLE ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1-3 19 372.57 1171.41 31.81 LONGI SOLAR LR4-60HPB 355M 355W MODULES 40.87" 69 . 0 9 " (E ) F R O N T O F CO M M E R C I A L B U I L D I N G S H A L L A D A Y S T (E ) B A C K O F CO M M E R C I A L B U I L D I N G ROOF #02 (11) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #03 (05) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #01 (03) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF ACCESS POINT (19) SOLAREDGE POWER OPTIMIZERS S-440 (50) CHIKOUSA L FOOT ATTACHMENTS @48"O.C. ROOF #1 TILT - 20° AZIM. - 182° ROOF #2 TILT - 20° AZIM. - 272° ROOF #3 TILT - 20° AZIM. - 92° 36 " F I R E S E T B A C K 36" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18 " F I R E S E T B A C K 18 " F I R E S E T B A C K 18" F I R E S E T B A C K 18" F I R E S E T B A C K (N) CHIKO ASPHALT ROOF RACKING SYSTEM - GAS METERGAS - SUB PANELSUB (E) MAIN SERVICE PANEL, 200A RATED, 240V (EXTERIOR) (E) UTILITY METER (N) AC DISCONNECT-1 (N) SOLAREDGE TECHNOLOGY : SE10KUS INVERTER INTEGRATED RAPID SHUTDOWN (E) GAS METER (N) SUB PANEL, 200A RATED, 240V (INTERIOR)(N) SECONDARY FUSED AC DISCONNECT-3 (N) PRIMARY FUSED AC DISCONNECT-2 (INTERIOR) (N) TRANSFORMER 3-PHASE 240V DELTA-208 Y 120 (INTERIOR) 3/4" EMT CONDUIT RUN ON ROOF (N) JUNCTION BOX - TRANSFORMERTNF Structural Only Signed 9/29/2023 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV ATTACHMENT DETAIL PAGE 4 OF 18 SCALE: NTS 2 PV-4 ATTACHMENT DETAIL SCALE: NTS 1 PV-4 ATTACHMENT DETAIL(enlarged view) PV MODULE SEE (2/PV-4) FOR ENLARGED VIEW (E) SINGLE LAYER OF COMP SHINGLE2"X4" RAFTE R S @ 24"O.C. 6" PV MODULE CHIKOUSA FLASHING COMPOSITION L-FOOT ATTACHMENT (E) SINGLE LAYER OF COMP SHINGLE GROUNDING & END/MID CLAMP CHIKO ASPHALT RACKING SYSTEM 2"x4" RAFTERS @ 24" O.C. 5/16" x 3 1/2" SS LAG BOLT INTO RAFTER(S) 2 1/2" MIN. PENETRATION SEALED W/ GEOCEL. CHIKOUSA CHANNEL NUT Structural Only Signed 9/29/2023 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT SPECIFICATION PAGE 13 OF 18 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT SPECIFICATION PAGE 14 OF 18 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-15 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT SPECIFICATION PAGE 15 OF 18 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-16 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT SPECIFICATION PAGE 16 OF 18 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-17 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV EQUIPMENT SPECIFICATION PAGE 17 OF 18 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV D02/14/2023 REV E02/16/2023 REV F02/20/2023 REV G 09/15/2023 REV ELECTRICAL LINE DIAGRAM MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 200 A (EXISTING) SOUTH (19) LONGI SOLAR LR4-60HPB 355M 355W MODULES (01) SOLAREDGE TECHNOLOGY:SE10KUS (208V) (19) SOLAREDGE POWER OPTIMIZERS S-440 (1) STRING OF 19 MODULES CONNECTED IN SERIES. SCALE: NTSPV-5 1 ELECTRICAL LINE DIAGRAM INTERCONNECTION 120% RULE UTILITY FEED + SOLAR BACKFEED 200A + 35A = 235A BUSS RATING x 120% 200A x 120% = 240A 200 A (EXISTING) PAGE 5 OF 18 SERVICE INFO UTILITY PROVIDER: SCE UNDERGROUND SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 6.75 kW DC TOTAL AC SYSTEM SIZE: 10.00 kW AC N/A 18 - + - + + - + + + +- - - 2 - + - 1 3 = = = = = = = = = = 1 19 LONGI SOLAR LR4-60HPB 355M 355W MODULES JUNCTION BOX 600 V, NEMA 3 UL LISTED 2 NOTE:- APPROVED MAIN SERVICE PANEL TO BE INSTALLED AT SITE. MAIN SERVICE PANEL TYPE :- SURFACE MOUNTED. Tag # THWN-2 - Ground Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) THWN-2 1 1 2 2 3 Bare Copper Ground (EGC/GEC) THWN-2 PV WIRE 10 AWG 8 AWG THWN-2 - Ground Description Wire Gauge # of Conductors/Color 10 AWG 6 AWG 8 AWG 8 AWG 2 (1V+, 1V-) 1 BARE 2 (1V+, 1V-) B/R 1 (GRN) 4 (1L1,1L2,1L3,1N)B/R/B/W 1 (GRN)3 Conduit Type Conduit Size EMT 3/4" 3/4" 3/4" 3/4" EMT EMT EMT INSIDE EMT-ON ROOF INSIDE EMT-ON ROOF 3/4" 3/4" L1 L2 L1 L2 N G N G AC DISCONNECT WITH IN 10' FROM METER G N GROUNDING ELECTRODE SYSTEM AC DISCONNECT-1 EATON#DG222URB 60A, 3P, 240VAC NEMA 3R L1 L2 N G = AC SOLAREDGE TECHNOLOGY: SE10KUS OUTPUT: 208 VAC, 27.8A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT & INTEGRATED RAPID SHUTDOWN DC 3 L3 L3 L3 3 BI-DIRECTIONAL UTILITY METER 3-PHASE, 4-W, 120V/240V WITH HIGH LEG. 208V IS PHASE C. UTILITY PROVIDER: SCE UTILITY METER NO: # 256000-083170 TO UTILITY GRID NL2 L1 L3 200A M (E) SUB-FEEDER BREAKER 200A/3P 240V (N) 35A/3P PV BREAKER AS FAR AS POSSIBLE FROM THE MAIN BREAKER (E) MAIN SERVICE PANEL, 200A RATED, 240V (EXTERIOR) SolarEdge Power Optimizer S440 Rated DC Input Power - 440 watts Maximum Input Voltage - 60 Vdc MPPT Range - 8 to 60 Vdc Maximum Input Current - 14.50 Adc Maximum Output Current - 15 Adc String Limitations - 16 to 50 Optimizers, 11250 watts STC per string maximum G N 200A 35A/2P 4 (N) SUB PANEL, 200A RATED, 240V (INTERIOR) (N) MAIN BREAKER TO HOUSE 240V, 200A/3P, (TOP FED) THWN-2 4 THWN-2 - Ground 250 kcmil 4 AWG 1 (GRN)4 2-1/2" 2-1/2" EMT EMT 4 (1L1,1L2,1L3,1N)B/R/B/W L1 L2 L1 L2 N G N G SECONDARY FUSED-AC DISCONNECT-3 EATON#DG322NRB 60A, 3P, 240VAC NEMA 3R L3 L3 L1 L2 L1 L2 N G N G (N) 15KVA TRANSFORMER 3-PHASE 240V DELTA-208 Y 120 (INTERIOR) L3 L3 35A 3 33 L1 L2 L1 L2 N G N G PRIMARY FUSED-AC DISCONNECT-2 EATON#DG322NRB 60A, 3P, 240VAC NEMA 3R L3 L3 35A 208 Y 120 240 DELTA MAIN BOND JUMPER Refer to original approved plans 20177759, Sheet PV-5 for important plan check notes. 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV PLACARDS NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2022 ARTICLE, UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , CA 9 2 7 0 5 ,US A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV G09/15/2023REV SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 27.8 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), DC DISCONNECTS. ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). WARNING! WARNING! WARNING! PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). INVERTER #1 SOLAREDGE MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX. RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC- CONVERTER (IF INSTALLED) 600VDC 15.0ADC 15.0ADC PAGE 7 OF 18 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). WARNING! CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN UTILITY METER & MAIN SERVICE PANEL AC DISCONNECT INVERTER (E) UTILITY METER 29 0 6 S H A L L A D A Y S T (N) INVERTER (N) SECONDARY FUSED AC DISCONNECT-3 (E) MAIN SERVICE PANEL (EXTERIOR) (N) SUB PANEL (INTERIOR) (N) AC DISCONNECT-1(N) PRIMARY FUSED AC DISCONNECT-2 (INTERIOR) (N) TRANSFORMER (INTERIOR) 2906 S Halladay St - 2018139112/4/2023 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV D02/14/2023 REV E02/16/2023 REV F02/20/2023 REV ELECTRICAL LINE DIAGRAM MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 200 A (EXISTING) SOUTH (19)LONGI SOLAR LR4-60HPB 355M 355W MODULES (01)SOLAREDGE TECHNOLOGY:SE9KUS (208V) (19)SOLAREDGE POWER OPTIMIZERS S-440 (1)STRING OF 10 MODULES CONNECTED IN SERIES. (1)STRING OF 09 MODULES CONNECTED IN SERIES. SCALE: NTSPV-5 1 ELECTRICAL LINE DIAGRAM INTERCONNECTION 120% RULE UTILITY FEED + SOLAR BACKFEED 200A + 35A = 235A BUSS RATING x 120% 200A x 120% = 240A 200 A (EXISTING) PAGE 5 OF 18 SERVICE INFO UTILITY PROVIDER:SCE UNDERGROUND SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 6.75 kW DC TOTAL AC SYSTEM SIZE: 5.00 kW AC N/A - + - + + - + + + +- - - 2 - + - 1 3 = = = = = = = = = = 09 - + - + + - + + + +- - - 2 - + - 1 3 = = = = = = = = = = 1 10 LONGI SOLAR LR4-60HPB 355M 355W MODULES JUNCTION BOX 600 V, NEMA 3 UL LISTED 2 NOTE:- APPROVED MAIN SERVICE PANEL TO BE INSTALLED AT SITE. MAIN SERVICE PANEL TYPE :- SURFACE MOUNTED. 08 09 Tag # THWN-2 - Ground Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) THWN-2 1 1 2 2 3 Bare Copper Ground (EGC/GEC) THWN-2 PV WIRE 10 AWG 8 AWG THWN-2 - Ground Description Wire Gauge # of Conductors/Color 10 AWG 6 AWG 8 AWG 8 AWG 4 (2V+, 2V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 4 (1L1,1L2,1L3,1N)B/R/B/W 1 (GRN)3 Conduit Type Conduit Size EMT 3/4" 3/4" 3/4" 3/4" EMT EMT EMT INSIDE EMT-ON ROOF INSIDE EMT-ON ROOF 3/4" 3/4" L1 L2 L1 L2 N G N G AC DISCONNECT WITH IN 10' FROM METER G N GROUNDING ELECTRODE SYSTEM AC DISCONNECT-1 EATON#DG222URB 60A, 3P, 240VAC NEMA 3R L1 L2 N G = AC SOLAREDGE TECHNOLOGY: SE9KUS OUTPUT: 208 VAC, 25A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT & INTEGRATED RAPID SHUTDOWN DC 3 L3 L3 L3 3 BI-DIRECTIONAL UTILITY METER 3-PHASE, 4-W, 120V/240V WITH HIGH LEG. 208V IS PHASE C. UTILITY PROVIDER: SCE UTILITY METER NO: # 256000-083170 TO UTILITY GRID NL2 L1 L3 200A M (E)SUB-FEEDER BREAKER 200A/3P 240V (N) 35A/3P PV BREAKER AS FAR AS POSSIBLE FROM THE MAIN BREAKER (E) MAIN SERVICE PANEL, 200A RATED, 240V (EXTERIOR) SolarEdge Power Optimizer S440 Rated DC Input Power - 440 watts Maximum Input Voltage - 60 Vdc MPPT Range - 8 to 60 Vdc Maximum Input Current - 14.50 Adc Maximum Output Current - 15 Adc String Limitations - 16 to 50 Optimizers, 11250 watts STC per string maximum G N 200A 35A/2P 4 (N) SUB PANEL, 200A RATED, 240V (INTERIOR) (N)MAIN BREAKER TO HOUSE 240V, 200A/3P, (TOP FED) THWN-2 4 THWN-2 - Ground 250 kcmil 4 AWG 1 (GRN)4 2-1/2" 2-1/2" EMT EMT 4 (1L1,1L2,1L3,1N)B/R/B/W L1 L2 L1 L2 N G N G SECONDARY FUSED-AC DISCONNECT-3 EATON#DG322NRB 60A, 3P, 240VAC NEMA 3R L3 L3 L1 L2 L1 L2 N G N G (N) 15KVA TRANSFORMER 3-PHASE 240V DELTA-208 Y 120 (INTERIOR) L3 L3 35A 3 33 L1 L2 L1 L2 N G N G PRIMARY FUSED-AC DISCONNECT-2 EATON#DG322NRB 60A, 3P, 240VAC NEMA 3R L3 L3 35A 208 Y 120 240 DELTA MAIN BOND JUMPER To ensure a ground fault current path, a System Bond Jumper must be installed at the xfmr secondary (bond N to G) -OR- a supply side bond jumper must be installed within the Fused Disconnect-3 (bond N to G). Either will be #8. CEC 250.28(D), 250.30(A)(1,2) 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022REV B09/27/2022REV C09/28/2022REV D02/14/2023REV E02/16/2023REV F02/20/2023REV PLACARDS NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2022 ARTICLE, UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV D02/14/2023 REV E02/16/2023 REV F02/20/2023 REV SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 25 .00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING ! LABEL LOCATION: INVERTER(S), DC DISCONNECTS. ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). WARNING! WARNING! WARNING! PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). INVERTER #1 SOLAREDGE MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX. RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC- CONVERTER (IF INSTALLED) 500VDC 30.0ADC 16.86ADC PAGE 7 OF 18 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). WARNING ! CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN UTILITY METER & MAIN SERVICE PANEL AC DISCONNECT INVERTER (E) UTILITY METER 29 0 6 S H A L L A D A Y S T (N) INVERTER (N) SECONDARY FUSED AC DISCONNECT-3 (E) MAIN SERVICE PANEL (EXTERIOR) (N) SUB PANEL (INTERIOR) (N) AC DISCONNECT-1(N) PRIMARY FUSED AC DISCONNECT-2 (INTERIOR) (N) TRANSFORMER (INTERIOR) 2906 S Halladay St - 101112511 & 2017775906/26/23 MSP UM ACD GAS SUBINV ACD ACD TNF JB STRING LAYOUT REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV D02/14/2023 REV E02/16/2023 REV F02/20/2023 REV 1 STRING LAYOUT PV-3 SCALE: 3/16" = 1'-0" PAGE 3 OF 18 STRING 2 STRING 1 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 19 LONGI SOLAR LR4-60HPB 355M 355W MODULES INVERTER 01 SOLAREDGE TECHNOLOGY: SE9KUS (208V) INVERTER INTEGRATED RAPID SHUTDOWN OPTIMIZER 19 SOLAREDGE POWER OPTIMIZERS S-440 AC DISCONNECT 1 AC DISCONNECT EATON#DG222URB 60A, 2P, 240VAC NEMA 3R AC DISCONNECT 2 FUSED AC DISCONNECT-3 EATON#DG322NRB 60A, 3P, 240VAC NEMA 3R SUB PANEL 1 SUB PANEL, 200A RATED, 240V TRANSFORMER 1 15KVA TRANSFORMER 3-PHASE, 240V DELTA-208 Y 120 ATTACHMENT 50 CHIKOUSA COMPOSITION L-FOOT ATTACHMENT RAILS 6 CHIKO ASPHALT ROOF RACKING SYSTEM 134" RAILS 6 CHIKO ASPHALT ROOF RACKING SYSTEM 166" RAIL SPLICE 4 SPLICE KIT MID CLAMPS 24 MID CLAMPS END CLAMPS 28 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 7 GROUNDING LUG S H A L L A D A Y S T (E ) FR O N T O F CO M M E R C I A L B U I L D I N G (E) BA C K O F CO M M E R C I A L B U I L D I N G 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE PAGE 6 OF 17 NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # LONGI SOLAR LR4-60HPB 355M 355 (355W)MODULES VMP 34.6 IMP 10.27 VOC 40.6 ISC 11.25 MODULE DIMENSION 69.09"L x 40.87"W x 1.50"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE TECHNOLOGY SE9KUS NOMINAL AC POWER 5.00KW NOMINAL OUTPUT VOLTAGE 208 VAC NOMINAL OUTPUT CURRENT 25A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2° AMBIENT TEMP (HIGH TEMP 2%)31° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 53° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%/°C EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 17.58A 1.25 X 1.25 X MODULE ISC DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 30.72ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (17.58A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c)+22° EXPECTED WIRE TEMP (In Celsius)31 +22 = 53 TEMP. CORRECTION PER TABLE (310.16)0.76 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.75A 1.25 X OPTIMIZER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 24.32A TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO SUBPANEL: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 8AWG CIRCUIT CONDUCTOR AMPACITY 55A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 31.25A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 42.24A TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM SUBPANEL TO MAIN SERVICE PANEL: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 250kcmil CIRCUIT CONDUCTOR AMPACITY 290A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 200.00A SUB-FEEDER BREAKER DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 222.72ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (200.00A) otherwise less the entry for circuit conductor size and ampacity 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV OPTIMIZER CHART 1-10 1 2 3 4 11-20 21-30 31-40 41-50 51-60 5 6 7 8 9 10 OPTIMIZER CHART PAGE 8 OF 17 S H A L L A D A Y S T 2906 S Halladay St - 101112511 & 2017775906/26/23 1 0 ' - 0 " 1 0 ' - 0 " 1 0 ' - 0 " REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT ELEVATION PAGE 9 OF 17 EQUIPMENT ELEVATION SCALE: NTS 1 PV-9 (N) SUBPANEL, 200A RATED, 240V (INTERIOR) (N) SOLAREDGE TECHNOLOGY : SE9KUS INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT (E) UTILITY METER (E) MAIN SERVICE PANEL, 200A RATED, 240V (EXTERIOR) 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT SPECIFICATION PAGE 10 OF 17 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT SPECIFICATION PAGE 11 OF 17 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT SPECIFICATION PAGE 13 OF 17 2906 S Halladay St - 101112511 & 2017775906/26/23 MSP UM ACD IN V JB 3' - 5" 1 3 ' - 1 0 " 7' - 0 " 8' - 0" 8'-7"3" 11'-7" 4'-5" 5'-9" 1'-6" GAS SUB REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV ROOF PLAN & MODULES ROOF DESCRIPTION ROOF TYPE COMP-SHINGLE ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 20°182° 2"x4"24" o.c. #2 20°272° 2"x4"24" o.c. #3 20°92° 2"x4"24" o.c. LEGEND - JUNCTION BOX MSP - MAIN SERVICE PANEL - VENTS, DISH (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT - UTILITY METER SCALE: 1/8" = 1'-0" - SOLAREDGE OPTIMIZER MODULE TYPE, DIMENSIONS & WEIGHT ACD - AC DISCONNECT - INVERTER 1 PV-2 NUMBER OF MODULES = 19 MODULES MODULE TYPE = LONGI SOLAR LR4-60HPB 355M 355W MODULES MODULE WEIGHT = 42.99 LBS / 19.5 KG. COMPONENT WEIGHT: 1.5 LBS. PER MODULE TOTAL DEAD LOAD: 845.31 LBS. POINT LOAD PER STANDOFF.: 845.31 LBS / 50 STANDOFF = 16.91 LBS MODULE DIMENSIONS = 69.09"x 40.87" = 19.61 SF UNIT WEIGHT OF ARRAY = 2.27 PSF UM JB INV ARRAY AREA WITH TOTAL ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 3 58.83 239.00 24.61 #2 11 215.71 488.60 44.15 #3 5 98.05 327.08 29.98 ROOF PLAN & MODULES PAGE 2 OF 17 ARRAY AREA WITH WHOLE ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1-3 19 372.57 1171.41 31.81 LONGI SOLAR LR4-60HPB 355M 355W MODULES 40.87" 69 . 0 9 " (E ) F R O N T O F CO M M E R C I A L B U I L D I N G S H A L L A D A Y S T (E ) B A C K O F CO M M E R C I A L B U I L D I N G ROOF #02 (11) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #03 (05) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF #01 (03) LONGI SOLAR LR4-60HPB 355M 355W MODULES ROOF ACCESS POINT (E) MAIN SERVICE PANEL, 200A RATED, 240V (EXTERIOR) (E) UTILITY METER (N) AC DISCONNECT (N) SOLAREDGE TECHNOLOGY : SE9KUS INVERTER INTEGRATED RAPID SHUTDOWN 3/4" EMT CONDUIT RUN ON ROOF (N) JUNCTION BOX (19) SOLAREDGE POWER OPTIMIZER S-440 (50) CHIKOUSA L FOOT ATTACHMENTS @48"O.C. ROOF #1 TILT - 20° AZIM. - 182° ROOF #2 TILT - 20° AZIM. - 272° ROOF #3 TILT - 20° AZIM. - 92° 36 " F I R E S E T B A C K 36" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 1 8" FI RE SET B AC K 1 8" FI RE SET B AC K 18 " FIRE SE T BAC K 18" FIRE SE T BAC K (N) CHIKO ASPHALT ROOF RACKING SYSTEM (E) GAS METER - GAS METERGAS (N) SUB PANEL, 200A RATED, 240V (INTERIOR) - SUB PANELSUB VECTOR PROJECT #: A0035-0204-221 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Electrical, mechanical, architectural, and all other nonstructural aspects of the design are by others. October 04, 2022 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV ATTACHMENT DETAIL PAGE 4 OF 17 SCALE: NTS 2 PV-4 ATTACHMENT DETAIL SCALE: NTS 1 PV-4 ATTACHMENT DETAIL(enlarged view) PV MODULE SEE (2/PV-4) FOR ENLARGED VIEW (E) SINGLE LAYER OF COMP SHINGLE2"X4" RAFTE R S @ 24"O.C. 6" PV MODULE CHIKOUSA FLASHING COMPOSITION L-FOOT ATTACHMENT (E) SINGLE LAYER OF COMP SHINGLE GROUNDING & END/MID CLAMP CHIKO ASPHALT RACKING SYSTEM 2"x4" RAFTERS @ 24" O.C. 5/16" x 3 1/2" SS LAG BOLT INTO RAFTER(S) 2 1/2" MIN. PENETRATION SEALED W/ GEOCEL. CHIKOUSA CHANNEL NUT VECTOR PROJECT #: A0035-0204-221 Vector Structural Engineering has reviewed the existing structure with loading from the solar array and lag screw connections to the existing framing. The design of the racking system, connections, and all other structure is by others. Electrical, mechanical, architectural, and all other nonstructural aspects of the design are by others. October 04, 2022 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT SPECIFICATION PAGE 14 OF 17 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT SPECIFICATION PAGE 15 OF 17 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-15 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT SPECIFICATION PAGE 16 OF 17 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-16 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT SPECIFICATION PAGE 17 OF 17 2906 S Halladay St - 101112511 & 2017775906/26/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-17 PROJECT ID VI C T O R P E R E Z 29 0 6 S H A L L A D A Y S T , SA N T A A N A , C A 9 2 7 0 5 , U S A FRESH07/02/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A08/31/2022 REV B09/27/2022 REV C09/28/2022 REV EQUIPMENT SPECIFICATION PAGE 17 OF 17 2906 S Halladay St - 101112511 & 2017775906/26/23 VSE Project Number: A0035-0204-221 July 27, 2022 NERD Power 2065 W. Obispo Ave., Suite 102 Gilbert, AZ 85233 REFERENCE: Victor Perez Residence: 2906 S Halladay St, Santa Ana, CA 92705 NERD Power Project: CA-R-193387 Solar Array Installation To Whom It May Concern: Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof as shown on the panel layout plan. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. Design Parameters Code: California Building Code, 2019 Edition (2018 IBC) Risk Category: II Design wind speed, Vult: 95 mph (3-sec gust) per ASCE 7-16 Wind exposure category: B Seismic design category: D Connection to Roof Mounting connection: (1) 5/16" lag screw w/ min. 2.5" threaded embedment into framing at max. 48" o.c. along rails (2) rails per row of panels, evenly spaced; panel length perpendicular to the rails not to exceed 69.6 in. Rail cantilever shall not exceed 50% of connection spacing. Conclusions Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array, other live loads will not be present or will be greatly reduced (2019 CBC, Section 1607.13.5). The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Regarding seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 7.1%. Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered. 1635 N. Greenfield Rd., Ste. 112 / Mesa, AZ 85205 / T (480) 648-3514 / www.vectorse.com Page 1 of 8 2906 S Halladay St - 101112511 & 2017775906/26/23 VSE Project Number: A0035-0204-221 Victor Perez Residence 7/27/2022 Limitations Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor must notify Vector Structural Engineering of Arizona, LLP should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. Connections to existing roof framing must be staggered, except at array ends, so as not to overload any existing structural member. The use of solar panel support span tables provided by others is allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. The design of the solar panel racking (mounts, rails, etc.) and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. Vector Structural Engineering of Arizona, LLP 07/27/2022 _______________________________________________________ Michael Gibbons, P.E. Project Engineer Enclosures MEG/cb 1635 N. Greenfield Rd., Ste. 112 / Mesa, AZ 85205 / T (480) 648-3514 / www.vectorse.com Page 2 of 8 July 29, 2022 2906 S Halladay St - 101112511 & 2017775906/26/23 JOB NO.: A0035-0204-221 SUBJECT: SEISMIC LOADS PROJECT: Victor Perez Residence CHECK INCREASE IN OVERALL SEISMIC LOADS 10.2 psf 2.3 psf 32% 10.9 psf 7.1% Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 7.1%. Because the increase is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing structure is permitted to remain unaltered. Addt'l Seismic Weight Estimated Roof Dead Load Solar Dead Load % Roof Covered Equiv. Total Dead Load Page 3 of 8 2906 S Halladay St - 101112511 & 2017775906/26/23 JOB NO.: A0035-0204-221 SUBJECT: WIND PRESSURE PROJECT: Victor Perez Residence Label: Note: Calculations per ASCE 7-16 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 95 Notes: Exposure Category: B Risk Category: II Importance Factor, I: ADDITIONAL INPUT & CALCULATIONS: Height of Roof, h [ft]:15 (Approximate) Comp/Cladding Location:Gable Roofs 7° < θ ≤ 20° Enclosure Classification: Zone 1, 2e GCp:2.00 Zone 1, 2e γ a:0.77 Zone 2n, 2r, 3e GCp: 2.91 Zone 2n, 2r, 3e γa:0.77 Zone 3r GCp: 3.48 Zone 3r γa:0.77 γa:0.40 α: 7 Table 26.11-1 zg [ft]: 1200 Table 26.11-1 Kh: 0.57 Table 26.10-1 Ke: 1.00 Table 26.9-1 Kzt: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 11.3 Equation 26.10-1 γE: 1.50 Section 29.4.4 γC: 0.95 Section 29.4.4 γP: 1.20 Section 29.4.4 p = q h (GC p )(γE )(γa ) p = q h (GC rn ), (GC rn ) = (γ p )(γc )(γ E )(GC rn ) nom Zone 1, 2e, p [psf]: 26.1 psf (1.0 W) Zone 2n, 2r, 3e, p [psf]: 38.0 psf (1.0 W) Zone 3r, p [psf]: 45.5 psf (1.0 W) (a = 3.3 ft) Fig. 29.4-8 WIND PRESSURES: Equation 29.4-7 Solar Panel Array Enclosed Buildings Figure 30.3-2B (negative coeff.) Components and Cladding Wind Calculations Page 4 of 8 2906 S Halladay St - 101112511 & 2017775906/26/23 JOB NO.: A0035-0204-221 SUBJECT: CONNECTION PROJECT: Victor Perez Residence Calculate Uplift Forces on Connection Pressure (0.6 Dead -0.6 Wind) (psf) Max Trib. Width1 (ft) Max Trib. Area2 (ft2) Max Uplift Force (lbs) Zone 1, 2e 14.3 4.0 11.6 166 Zone 2n, 2r, 3e 21.4 4.0 11.6 249 Zone 3r 26.0 4.0 11.6 301 Calculate Connection Capacity Lag Screw Size [in]:5/16 Cd:1.6 NDS Table 2.3.2 Embedment3 [in]:2.5 Grade: Nominal Capacity [lbs/in]:205 NDS Table 12.2A Number of Screws:1 Prying Coefficient:1.4 Total Capacity [lbs]:586 Determine Result Maximum Demand [lbs]: 301 Lag Screw Capacity [lbs]: 586 Result: Capacity > Demand, Connection is adequate. Notes 1. 'Max Trib. Width' is the width along the rails tributary to the connection. 2. 'Max Trib Area' is the product of the 'Max. Trib Width' and 1/2 the panel width/height perpendicular to the rails. (2) rails per row of panels. Length of panels perpendicular to the rails shall not exceed 70". SPF (G = 0.42) 3. Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective. The length of the tapered tip is not part of the embedment length. Page 5 of 8 2906 S Halladay St - 101112511 & 2017775906/26/23 VECTOR STRUCTURAL ENGINEERS JOB NO.: A0035-0204-221 SUBJECT: GRAVITY LOADS PROJECT: Victor Perez Residence GRAVITY LOADS Roof Pitch:4.4 :12 ROOF DEAD LOAD (D) Increase due to pitch Material weight [psf] Composite Shingles 1.06 2.0 1/2" Plywood 1.06 1.0 Framing 1.00 3.0 Insulation 1.00 0.0 1/2" Gypsum Clg.1.06 0.0 M, E & Misc 1.00 0.0 Total Existing Roof DL PV Array DL 1.06 2 DL:1.06 ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf]20 ASCE 7-16 Table 4.3-1 Roof Live Load With PV Array [psf]0 SNOW LOAD (S):w/ Solar Array Roof Slope [x:12]:4.4 Roof Slope [°]:20 Ground Snow Load, pg [psf]:0 ASCE 7-16, Section 7.2 Terrain Category:B ASCE 7-16, Table 7.3-1 Exposure of Roof:Fully Exposed ASCE 7-16, Table 7.3-1 Exposure Factor, Ce:0.9 ASCE 7-16, Table 7.3-1 Thermal Factor, Ct:1.1 ASCE 7-16, Table 7.3-2 Risk Category:II ASCE 7-16, Table 1.5-1 Importance Factor, Is:1.0 ASCE 7-16, Table 1.5-2 Flat Roof Snow Load, pf [psf]:0 ASCE 7-16, Equation 7.3-1 Minimum Roof Snow Load, pm [psf]:0 ASCE 7-16, Section 7.3.4 Unobstructed Slippery Surface?Yes ASCE 7-16, Section 7.4 Slope Factor Figure:Figure 7-2b ASCE 7-16, Section 7.4 Roof Slope Factor, Cs:0.83 ASCE 7-16, Figure 7.4-1 Sloped Roof Snow Load, ps [psf]:0 ASCE 7-16, Equation 7.4-1 Design Snow Load, S [psf]:0 1.00 0 Design material weight [psf] 2.1 1.1 3.0 0.0 0.0 0.0 6.2 2.4 #VALUE! 2019 CBC, Section 1607.13.5 Existing 0 4.4 20 0 B Fully Exposed 0.9 1.1 II 1.0 0 0 No Figure 7-2b Page 6 of 8 2906 S Halladay St - 101112511 & 2017775906/26/23 JOB NO.: A0035-0204-221 SUBJECT: LOAD COMPARISON PROJECT: Victor Perez Residence Summary of Loads Existing With PV Array D [psf]6 9 Lr [psf]20 0 S [psf]0 0 Maximum Gravity Loads: Existing With PV Array (D + Lr) / Cd [psf] 21 10 ASCE 7-16, Section 2.4.1 (D + S) / Cd [psf] 7 10 ASCE 7-16, Section 2.4.1 Maximum Gravity Load [psf]: 21 10 Ratio Proposed Loading to Current Loading:46% OK The gravity loads, and thus the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is permitted to remain unaltered. (Cd = Load Duration Factor = 0.9 for D, 1.15 for S, and 1.25 for Lr) Page 7 of 8 2906 S Halladay St - 101112511 & 2017775906/26/23 VECTOR STRUCTURAL ENGINEERS JOB NO.: A0035-0204-221 SUBJECT: SOLAR LAYOUT PROJECT: Victor Perez Residence Page 8 of 8 2906 S Halladay St - 101112511 & 2017775906/26/23