3730 S Bristol St - Plan
N EXTERIOR LIGHTING PROGRAM VICINITY MAP 3730 S Bristol St Santa Ana, CA 92704 âBank of America CALIFORNIA ATM LIGHTING REQUIREMENTS: CALIFORNIA FINANCE CODE SECTIONS 13000-13070 www.gmr1.com Office: (972) 771-6038 1629 Smirl Drive, Suite 200, Heath, Texas 75032 DRAWING INDEX: - LU-1 LU-2 LU-3 LU-4 E-0 E-1 E-2 E-3 COVER SHEET GENERAL NOTES LUMINAIRE SCHEDULE FULL SITE PHOTOMETRICS PLAN AT GRADE ATM COMPLIANCE AREA PHOTOMETRICS PLAN GENERAL NOTES & SCHEDULES SITE PLAN - LIGHTING TITLE 24 DOCUMENTS TITLE 24 DOCUMENTS CA6-204 3730 S Bristol St Santa Ana, CA v3 200827 SCOPE OF WORK: APN NUMBER: 412-131-12 - - - - - 26 17 10 9 2 REPLACE EXISTING FIXTURE REMOVE AND PATCH ADD NEW POLE AND FIXTURE ADD NEW FIXTURE WASH AND RELAMP PLANS DESIGNED TO CALIFORNIA LEGISLATIVE 13040 & 13041 ATM LIGHTING STANDARDS. DUE TO CRITERIA OF ATM STANDARDS, LOCAL JURISDICTION LIGHTING CODE MAY NOT BE MET. Jill Arabe 11/03/2020 Tung Le 12/07/2020 BLDG #101104889 ELECT#20172411 Police- William McGovern approved 11/10/2020 Police Final Inspection required. Public Works ok per Jason Kwak 12/15/2020 2020-161485 12/15/20 x x 2020-161485 12/15/20 N EXTERIOR LIGHTING PROGRAM VICINITY MAP 3730 S Bristol St Santa Ana, CA 92704 âBank of America CALIFORNIA ATM LIGHTING REQUIREMENTS: CALIFORNIA FINANCE CODE SECTIONS 13000-13070 www.gmr1.com Office: (972) 771-6038 1629 Smirl Drive, Suite 200, Heath, Texas 75032 DRAWING INDEX: - LU-1 LU-2 LU-3 LU-4 E-0 E-1 E-2 E-3 COVER SHEET GENERAL NOTES LUMINAIRE SCHEDULE FULL SITE PHOTOMETRICS PLAN AT GRADE ATM COMPLIANCE AREA PHOTOMETRICS PLAN GENERAL NOTES & SCHEDULES SITE PLAN - LIGHTING TITLE 24 DOCUMENTS TITLE 24 DOCUMENTS CA6-204 3730 S Bristol St Santa Ana, CA v3 200827 SCOPE OF WORK: APN NUMBER: 412-131-12 - - - - - 26 17 10 9 2 REPLACE EXISTING FIXTURE REMOVE AND PATCH ADD NEW POLE AND FIXTURE ADD NEW FIXTURE WASH AND RELAMP PLANS DESIGNED TO CALIFORNIA LEGISLATIVE 13040 & 13041 ATM LIGHTING STANDARDS. DUE TO CRITERIA OF ATM STANDARDS, LOCAL JURISDICTION LIGHTING CODE MAY NOT BE MET. Jill Arabe 11/03/2020 Tung Le 12/07/2020 BLDG #101104889 ELECT#20172411 Police- William McGovern approved 11/10/2020 Police Final Inspection required. Public Works ok per Jason Kwak 12/15/2020 2020-161485 12/15/20 âBank of America LU-1 GENERAL NOTES GENERAL NOTES: 1. EXISTING CONDITIONS SHOWN ON THE DRAWINGS ARE BASED ON A LIMITED AMOUNT OF INFORMATION AVAILABLE TO THE ENGINEER. ALL SUCH CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO SUBMITTING THE BID AND ADJUSTED IF NECESSARY. NO ADDITIONAL COMPENSATION SHALL BE GRANTED AFTER AWARDING A BID FOR ANY EQUIPMENT, MATERIAL OR LABOR REQUIRED TO REWORK OR OTHERWISE MODIFY EXISTING CONDITIONS. 2. THIS LIGHTING DESIGN IS BASED ON A COMBINATION OF STATE STANDARDS, THE BANK'S CURRENT SECURITY POLICY FOR EXTERIOR ATM AND AFTER-HOUR DEPOSITORIES AND BANK GUIDELINES FOR NON-SECURITY COMPLIANCE ZONES. 3. TRIM ALL TREES/LANDSCAPING TO MINIMIZE IMPEDING LIGHT FROM ANY LIGHT FIXTURES THAT IMPACT THE 60' RADIUS AROUND ALL ATMS AND A RADIUS OF 50' AROUND ALL AFTER-HOUR DEPOSITORIES. CONSIDERATION MUST BE GIVEN TO TREES/LANDSCAPING IN A STATE OF FULL FOLIAGE/BLOOM AND FUTURE GROWTH. ALL LANDSCAPING WORK WILL BE PERFORMED BY OTHERS WITH A SEPARATE PERMIT (IF REQUIRED). 4. ALL MOUNTING HEIGHTS ARE INTENDED TO THE BOTTOM OF THE FIXTURE. 5. CONTRACTOR TO FIELD VERIFY FIXTURE PLACEMENT DIMENSIONS PRIOR TO CONSTRUCTION. 6. DIMENSIONING PROVIDED IS FOR PROPOSED FIXTURE LOCATIONS ONLY, UNLESS OTHERWISE NOTED ON THE DRAWING. 7. THE CONTRACTOR SHALL ATTEMPT TO ELIMINATE THE USE OF EXPOSED CONDUIT WHERE POSSIBLE. IF EXPOSED CONDUIT IS NECESSARY, THE CONTRACTOR SHALL VERIFY USE WITH PROJECT MANAGER. 8. ALL EXISTING LIGHTS WILL BE REPLACED WITH LED LIGHTS AND ALL PROPOSED LIGHTS WILL ALSO BE LED, UNLESS OTHERWISE NOTED. 9. ALL FIXTURES ARE TO BE MOUNTED ABOVE FINISH GRADE. 10. UNLESS OTHERWISE NOTED, MATCH EXISTING POLE BASES. FIXTURE CLARIFICATION NOTES: 1. OUT OF SCOPE - EXISTING FIXTURES TO REMAIN ON SITE WITHOUT MODIFICATION. NO ACTION REQUIRED UNLESS NOTED OTHERWISE. 2. REMOVE AND PATCH - EXISTING FIXTURES TO BE FULLY REMOVED AND ANY PAINTING, PATCHING OR ELECTRICAL WORK NEEDED IS TO BE ASSESSED AND PERFORMED BY CONTRACTOR. 3. REPLACE EXISTING FIXTURE - EXISTING FIXTURE TO BE FULLY REMOVED AND REPLACED IN THE SAME LOCATION WITH A NEW FIXTURE. CONTRACTOR TO VERIFY IF POLE AND/OR POLE BASE IS SUFFICIENT FOR THE NEW FIXTURES. ANY PAINTING, PATCHING OR ELECTRICAL WORK NEEDED IS TO BE ASSESSED AND PERFORMED BY CONTRACTOR. 4. ADD NEW FIXTURE - NEW FIXTURES TO BE ADDED. ANY PAINTING, PATCHING OR ELECTRICAL WORK NEEDED TO BE ASSESSED AND PERFORMED BY CONTRACTOR. 5. ADD NEW POLE & FIXTURE - A NEW POLE AND FIXTURE TO BE ADDED. CONTRACTOR TO SPECIFY POLE TO MATCH EXISTING STYLE AND COLOR AND, IF NOT PROVIDED, POLE BASE DATA FOR NEW POLE LOCATIONS. CONTRACTOR TO VERIFY IF POLE AND POLE BASE IS SUFFICIENT FOR THE HEIGHT, LOCATION AND FIXTURE SPECIFIED. 6. GMR DOES NOT SPECIFY MOUNTING HARDWARE FOR ANY SPECIFIED FIXTURES. CONTRACTOR IS TO WORK WITH DISTRIBUTOR AND/OR MANUFACTURER ON A CASE BY CASE BASIS TO IDENTIFY AND ORDER REQUIRED MOUNTING HARDWARE. 7. CONTRACTOR TO VERIFY WHETHER EXISTING WIRING LOCATIONS OR THE ADDITION OF WIRING FOR NEW FIXTURE LOCATIONS IS SUFFICIENT FOR THE DESIGNATED FIXTURE LOCATION. 8. CONTRACTOR TO SPECIFY POLE COLOR AND TYPE PRIOR TO ORDERING. 9. ALL FIXTURES ARE ASSUMED BRONZE IN COLOR UNLESS NOTED OTHERWISE IN THE LUMINAIRE SCHEDULE. CONTRACTOR TO CONFIRM PRIOR TO ORDERING. CONTROLS & ADDITIONAL NOTES: LIGHTING CONTROL NOTES: THE CONTRACTOR SHALL VERIFY THE CONTROLS FOR ALL EXTERIOR LIGHTING AND ATM/AHD INTERIOR LOBBIES ON THE SITE (EXCLUDING SIGNAGE) AND ADJUST ACCORDING TO THE FOLLOWING: · IC3 CONTROL CONTRACTOR SHALL VERIFY THAT EXTERIOR LIGHTING CIRCUITS ARE CONTROLLED BY THE CORRECT IC3 CIRCUIT. WHERE EXTERIOR LIGHTING IS INCLUDED ON CONTROL CIRCUITS FOR INTERIOR SYSTEMS, INTERIOR LIGHTING, OR EXTERIOR SIGNAGE, CONTRACTOR SHALL ADJUST EXTERIOR LIGHTING TO THE CORRECT CONTROL CIRCUIT AS REQUIRED. · PHOTOCELL CONTROL: CONTRACTOR SHALL REPLACE EXISTING PHOTOCELLS WITH NEW AND INSTALL IN A LOCATION BEST SUITED TO PROVIDE APPROPRIATE LIGHT EXPOSURE SUCH THAT EXTERIOR LIGHTS ARE ON DURING DARKNESS. · TIME CLOCK CONTROL: CONTRACTOR SHALL VERIFY LOCATION OF TIME CLOCK. IF TIME CLOCK IS IN ELECTRICAL ROOM ALONG WITH IC3 CONTROLS, CONTRACTOR SHALL ADJUST CIRCUIT TO BE CONTROLLED BY IC3 EXTERIOR LIGHTING CONTROLS. IF TIME CLOCK IS IN A REMOTE LOCATION NOT IN CLOSE PROXIMITY TO THE IC3 CONTROLS, CONTRACTOR SHALL VERIFY TIME CLOCK IS SET PROPERLY AND LEAVE CIRCUIT ON TIME CLOCK CONTROL. · MANUAL CONTROL: CONTRACTOR SHALL VERIFY THAT NO EXTERIOR LIGHTING IS CONTROLLED MANUALLY. IF ANY EXTERIOR LIGHTING IS ON A MANUALLY CONTROLLED CIRCUIT, CONTRACTOR SHALL ADJUST TO BE CONTROLLED BY PHOTOCELL OR IC3, WHICHEVER IS MOST ECONOMICALLY ACCOMPLISHED. ADDITIONAL CONTRACTOR NOTES: CONSTRUCTION COMPLETION VERIFICATION UPON COMPLETION OF THE WORK, THE CONTRACTOR SHALL PROVIDE VERIFICATION IN WRITING TO THE BANK OF AMERICA PJM THAT ALL WORK IS COMPLETE ACCORDING TO THE CONSTRUCTION DOCUMENTS, AND THAT ALL EXTERIOR LIGHTING IS FUNCTIONING DURING NIGHTTIME HOURS. COMPLETION PHOTOS, TAKEN AT NIGHT, SHALL BE PROVIDED IN THE FOLLOWING FORMAT: PROVIDE A SINGLE DOCUMENT CONTAINING THE FOLLOWING: · SITE PHOTOS FROM ALL SIDES OF BUILDING · MINIMUM OF 3 PHOTOS OF EACH COMPLIANCE AREA (ATM(S), AFTER-HOUR DEPOSITORIES, ASSOCIATE ENTRY) FROM DIFFERENT ANGLES · MINIMUM OF 2 PHOTOS OF ALL NON-COMPLIANCE AREAS FROM DIFFERENT ANGLES DESCRIPTIONREVISION NO. 1 2 3 REVISED BY CITY COMMENTS 08/31/2020 KRM DESIGN BY: REVIEWED BY: DRAWN BY: APPROVED BY: KRM AWDCLS MLP South Coast Center CA6-204 3730 S Bristol St Santa Ana, CA CONTRACTOR RESPONSIBILITY NOTES: 1. CONTRACTOR SHALL BE RESPONSIBLE FOR PERMITTING, INCLUDING COORDINATION WITH THE LOCAL JURISDICTION AND ANY ASSOCIATED PERMIT FEES OR PROCESSING. CONTRACTOR SHALL NOTIFY GMR UPON RECEIPT OF PERMIT. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITTING DOCUMENTS THAT ARE NOT INCLUDED IN THE LIGHTING DESIGN PACKAGE. THESE INCLUDE, BUT ARE NOT LIMITED TO, STAMPED ELECTRICAL DRAWINGS, STAMPED POLE BASE DRAWINGS, AND PROFESSIONAL SURVEYS. 3. SHOULD STAMPED PHOTOMETRIC DRAWINGS BE REQUIRED, CONTRACTOR SHALL ENGAGE LOCAL ENGINEER OR LIGHTING DESIGNER AS REQUIRED TO PROVIDE STAMP ON GMR PHOTOMETRIC DESIGN DOCUMENTS. 4. CONTRACTOR SHALL PROVIDE THE BANKING CENTER NOTIFICATION AT LEAST ONE WEEK IN ADVANCE OF VISITING SITES OR STARTING WORK. 5. CONTRACTOR SHALL VERIFY VOLTAGE REQUIREMENTS FOR FIXTURES PRIOR TO PLACEMENT OF FIXTURE ORDERS. 6. CONTRACTOR TO VERIFY LIGHTING CONTROLS PRIOR TO BEGINNING CONSTRUCTION. SEE LIGHTING CONTROL NOTES. 7. CONTRACTOR SHALL RECEIVE FORMAL APPROVAL FROM GMR ON ANY FIXTURE MODIFICATIONS OR VARIATIONS FROM THE LUMINAIRE SCHEDULE. 8. CONTRACTOR SHALL VERIFY EXISTING AND PROPOSED FIXTURE MOUNTING CONDITIONS IN FIELD. ANY SPECIAL MOUNTING HARDWARE NEEDED FOR PROPOSED FIXTURES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 9. CONTRACTOR SHALL SUPPLY ALL NEW LIGHT POLES. NEW LIGHT POLES SHALL MATCH EXISTING CONDITIONS ON SITE FOR POLE TYPE AND PAINT COLOR. 10. CONTRACTOR SHALL ORDER ALL FIXTURES FROM BORDER STATES IN ACCORDANCE WITH BANK OF AMERICA NATIONAL ACCOUNT. CONTACT NATIONAL ACCOUNT QUOTES DEPARTMENT AT BOA@BORDERSTATES.COM OR 704-372-3040. 11. CONTRACTOR SHALL PERFORM ALL NECESSARY PATCHING OR REPAINTING FOR ADDED, REMOVED, OR REPLACED FIXTURES. 12. CONTRACTOR SHALL REPAIR ANY DISTURBED AREAS BACK TO EXISTING CONDITION INCLUDING PAVED AREAS, LANDSCAPED AREAS, ETC. 13. CONTRACTOR SHALL VERIFY AND DOCUMENT COMPLETED WORK DURING NIGHT HOURS. ALL FIXTURES MUST BE FUNCTIONAL DURING NIGHT HOURS PRIOR TO SCHEDULING A FINAL SURVEY WITH GMR. 14. CONTRACTOR SHALL PROVIDE BEFORE AND AFTER NIGHT TIME PHOTOS OF THE SITE. 15. CONTRACTOR SHALL UTILIZE THE “BOA ELP INCENTIVE SITE SURVEY FORM” TO DOCUMENT THE EXACT DETAILS OF EACH FIXTURE BEING REMOVED FOR REBATE AND ENERGY SAVINGS CALCULATION PURPOSES. 16. CONTRACTOR SHALL RECEIVE A PUNCHLIST FROM GMR UPON FINAL SURVEY FOR ANY REMAINING ITEMS TO BE COMPLETED. NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. v3 200827 SITE ABBREVIATIONS: = PROPERTY LINE = ABOVE FINISHED GRADE = FOOTCANDLE = CONTROLLED BY OTHERS = AFTER HOUR DEPOSITORY PL AFG Fc CBO AHD 2020-161485 12/15/20 âBank of America LU-2 LUMINAIRE SCHEDULE BLUE GREEN ORANGE = NEW FIXTURE = EXISTING FIXTURE LOCATION TO BE REPLACED = EXISTING FIXTURE TO REMAIN = FIXTURE TO BE REMOVEDTURQUOISE PINK= REPLACE WITH NEW POLE AT NEW HEIGHT DESCRIPTIONREVISION NO. 1 2 3 REVISED BY CITY COMMENTS 08/31/2020 KRM DESIGN BY: REVIEWED BY: DRAWN BY: APPROVED BY: KRM AWDCLS MLP South Coast Center CA6-204 3730 S Bristol St Santa Ana, CA NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. v3 200827 LUMINAIRE SCHEDULE **SEE FIXTURE CLARIFICATION NOTE #9 (NP) = NEW POLE (CBO) CONTROLLED BY OTHERS SYMBOL QTY LABEL FIXTURE ARRANGEMENT TOTAL FIXTURE COUNT NEW POLE COUNT FIXTURE TYPE / MOUNTING / MANUFACTURER BUG RATING MOUNTING HEIGHT MOUNTING ACCESSORIES NOTES 4 BO1 SINGLE (BO) CPY250-A-DM-F-20W-UL-WH-40K / CANOPY MOUNT / CREE MATCH EXISTING 3 BO2 SINGLE (BO) CPY250-A-DM-F-20W-UL-WH-40K / CANOPY MOUNT / CREE 9' - 6'' AFG 9 DX1 SINGLE (DX) CR6T-825L-40K-12-E26GU24 / CANOPY MOUNT / CREE MATCH EXISTING 6 DX2 SINGLE (DX) CR6T-825L-40K-12-E26GU24 / CANOPY MOUNT / CREE 14' - 9'' AFG 1 DZ1 SINGLE (DZ) CR6T-1600L-40K-12-E26GU24 / CANOPY MOUNT / CREE MATCH EXISTING 2 EK1 SINGLE (EK) ZR22C-40L-40K-10V-FD (LED 2x2) / RECESSED CANOPY MOUNT / CREE MATCH EXISTING 3 SA1 SINGLE (SA) SEC-EDG-2S-WM-02-E-UL-BZ-350-40K / WALL MOUNT / CREE MATCH EXISTING 5 SH1 SINGLE (SH) SEC-EDG-4M-WM-02-E-UL-BZ-350-40K / WALL MOUNT / CREE MATCH EXISTING 2 UU1 SINGLE ALN440-Y5-32LED-4K-700-BL-SLA1 / POLE MOUNT / HUBBELL MATCH EXISTING 3 UU2 (NEW POLE) SINGLE ALN440-Y5-32LED-4K-700-BL-SLA1 / POLE MOUNT / HUBBELL 10' AFG 1 UU3 (NEW POLE) TRIPLE (3@90°) XGBM-FT-LED-LW-NW-UE-BLK / POLE MOUNT / LSI 30' AFG 1 UU4 (NEW POLE) TRIPLE (3@90°) XGBM-FT-LED-SS-NW-UE-BRZ / POLE MOUNT / LSI 30' AFG 1 UU5 (NEW POLE) SINGLE XGBM-FT-LED-HO-NW-UE-BLK / POLE MOUNT / LSI 30' AFG 3 RC1 SINGLE EXISTING FLOOD FIXTURE - 7 RD1 SINGLE EXISTING CANOPY FIXTURE - 3 RE1 SINGLE EXISTING CANOPY FIXTURE - 4 RG1 SINGLE EXISTING CANOPY FIXTURE - 2 XN1 SINGLE BOA DRIVE UP ATM 8' FIXTURE (GEWH9640BAT) - ** CONTRACTOR TO VERIFY MOUNTING ACCESSORIES BEFORE ORDERING** - - - - - - - - - 3 1 1 1 - - - - - 4 3 9 6 1 2 3 5 2 3 3 3 1 3 7 3 4 2 B1-U0-G1 B1-U0-G1 B1-U0-G0 B1-U0-G0 B1-U0-G0 B2-U0-G1 B1-U0-G1 B1-U0-G1 B3-U3-G2 B3-U3-G2 B1-U0-G3 B1-U0-G3 B2-U0-G4 - - - - - XA-BXCC9001 - - - - - - - - GR8 TRIM RING GR8 TRIM RING & REMODEL HOUSING REQUIRED GR8 TRIM RING DGA22-WHT - - - - - REPLACE EXISTING FIXTURE ADD NEW FIXTURE - MATCH EXISTING CANOPY HEIGHT REPLACE EXISTING FIXTURE ADD NEW FIXTURE - MATCH EXISTING CANOPY HEIGHT REPLACE EXISTING FIXTURE REPLACE EXISTING FIXTURE REPLACE EXISTING FIXTURE REPLACE EXISTING FIXTURE REPLACE EXISTING FIXTURE ADD NEW POLE AND FIXTURE ADD NEW POLE AND FIXTURE ADD NEW POLE AND FIXTURE ADD NEW POLE AND FIXTURE REMOVE AND PATCH REMOVE AND PATCH REMOVE AND PATCH REMOVE AND PATCH WASH AND RELAMP EXTENDED B.U.G. RATING SCHEDULE Label Lum. Watts LCS-FL LCS-FM LCS-FH LCS-FVH LCS-BL LCS-BM LCS-BH LCS-BVH LCS-UL LCS-UH BO1 20 325.7 543.1 120.6 10.6 325.7 543.1 120.6 10.6 0.0 0.0 BO2 20 325.7 543.1 120.6 10.6 325.7 543.1 120.6 10.6 0.0 0.0 DX1 11 142.0 220.2 43.9 3.6 143.3 224.3 44.1 3.6 0.0 0.0 DX2 11 142.0 220.2 43.9 3.6 143.3 224.3 44.1 3.6 0.0 0.0 DZ1 19.6 294.8 462.7 93.5 7.7 295.2 463.1 93.1 7.5 0.0 0.0 EK1 32 538.9 1002.8 426.2 64.9 537.0 975.6 402.3 52.3 0.0 0.0 SA1 25 257.5 1020.6 361.7 8.8 206.9 525.9 279.3 3.1 0.0 0.0 SH1 25 135.2 854.1 612.8 19.4 108.5 532.2 234.0 4.7 0.0 0.0 UU1 74.3 94.0 797.6 1272.9 221.3 94.0 797.6 1272.9 221.3 78.4 95.3 UU2 (NEW POLE) 74.3 94.0 797.6 1272.9 221.3 94.0 797.6 1272.9 221.3 78.4 95.3 UU3 (NEW POLE) 136.4 1559.5 5409.7 3979.3 279.9 292.7 502.4 181.5 11.7 0.0 0.0 UU4 (NEW POLE) 189 2242.1 7599.6 5633.8 296.0 433.6 730.6 274.0 20.5 0.0 0.0 UU5 (NEW POLE) 289.1 3073.2 10362.5 7696.8 398.5 590.0 994.0 369.3 27.8 0.0 0.0 XN1 40 663.5 1271.2 564.9 133.0 679.2 1332.8 607.6 143.7 178.7 341.4 2020-161485 12/15/20 âBank of America LU-3 FULL SITE PHOTOMETRICS PLAN BLUE GREEN ORANGE = NEW FIXTURE = EXISTING FIXTURE LOCATION TO BE REPLACED = EXISTING FIXTURE TO REMAIN = FIXTURE TO BE REMOVEDTURQUOISE PL = PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATION PINK = REPLACE WITH NEW POLE AT NEW HEIGHT = INDICATES NEW SECURITY FENCE N.T.S. CALLEN'S COMMON DX1DX1 EK1 EK1 DX1 DX1 DX1 DX1 DX1 DX1 SH1 SA1 BO1 BO1 BO1 BO1 XN1 XN1 SA1 SH1 SH1 DX2 DX2 DX1 DX2 BO2 BO2 BO2 UU2 (NEW POLE) UU2 (NEW POLE) UU1 UU1 UU2 (NEW POLE) SH1 DX2 DX2 DZ1 DX2 SH1 ATM1 ATM3 AHD ATM2 ASSOCIATE ENTRY ATM4 ATM5 PL PL PL PL PL PL PL SITE NOTE 3 SITE NOTE 1 SITE NOTE 4 SITE NOTE 2 SA1 UU3 (NEW POLE) UU4 (NEW POLE) UU5 (NEW POLE) DESCRIPTIONREVISION NO. 1 2 3 REVISED BY CITY COMMENTS 08/31/2020 KRM DESIGN BY: REVIEWED BY: DRAWN BY: APPROVED BY: KRM AWDCLS MLP South Coast Center CA6-204 3730 S Bristol St Santa Ana, CA FULL SITE CALCS Label CalcType Units Avg Max Min Avg/Min Max/Min FULL SITE @ GRADE Illuminance Fc 2.70 17.4 0.0 N.A. N.A. NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. v3 200827 NOTES: 1. THE SCOPE OF WORK FOR THIS PROJECT IS LIMITED TO EXTERIOR LIGHTING RENOVATIONS AS SHOWN ON THE PLANS. 2. ALL PROPOSED LIGHTS WILL BE FULL CUTOFF LED LIGHT FIXTURES. 3. ALL EXISTING LIGHTS WILL BE REPLACED WITH FULL CUT OFF LED LIGHT FIXTURES. 4. REFERENCE THE LUMINAIRE SCHEDULE (SHEET LU-2) FOR ADDITIONAL LIGHT FIXTURE INFORMATION. N LPD Area Summary Label Area Total Watts LPD LPD Units TITLE 24 42221 2225.4 0.053 Watts/Sq.Ft. 1. 2. 3. 4. CONTRACTOR TO WASH AND RELAMP CANOPY FIXTURE - SEE EXHIBIT `A'. CONTRACTOR TO INSTALL METAL PLATE FOR INSTALLATION OF NEW CANOPY FIXTURE - SEE EXHIBIT `B'. CONTRACTOR TO WASH AND RELAMP CANOPY FIXTURE - SEE EXHIBIT `C'. CONTRACTOR TO INSTALL METAL PLATE FOR INSTALLATION OF NEW CANOPY FIXTURE - SEE EXHIBIT `D'. SITE NOTES: EXISTING POLE BASES - 3' EXISTING DRIVE THRU CEILING - HARD EXISTING POLES - SQUARE - STEEL 2. 3. 1. EXISTING CONDITIONS: 2020-161485 12/15/20 âBank of America LU-4 ATM COMPLIANCE AREA PHOTOMETRICS PLAN SCALE: 1" = 1'-0" BLUE GREEN ORANGE = NEW FIXTURE = EXISTING FIXTURE LOCATION TO BE REPLACED = EXISTING FIXTURE TO REMAIN = FIXTURE TO BE REMOVEDTURQUOISE PL = PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATION PINK = REPLACE WITH NEW POLE AT NEW HEIGHT = INDICATES NEW SECURITY FENCE CALLEN'S COMMON DX1DX1 EK1 EK1 DX1 DX1 DX1 DX1 DX1 DX1 SH1 SA1 BO1 BO1 BO1 BO1 XN1 XN1 SA1 SH1 SH1 DX2 DX2 DX1 DX2 BO2 BO2 BO2 UU2 (NEW POLE) UU2 (NEW POLE) UU1 UU1 UU2 (NEW POLE) SH1 DX2 DX2 DZ1 DX2 SH1 ATM1 ATM3 AHD ATM2 ASSOCIATE ENTRY ATM4 ATM5 PL PL PL PL PL PL PL SA1 COMPLIANCE AREA 50' RADIUS COMPLIANCE AREA 50' RADIUS UU3 (NEW POLE) UU4 (NEW POLE) UU5 (NEW POLE) DESCRIPTIONREVISION NO. 1 2 3 REVISED BY CITY COMMENTS 08/31/2020 KRM DESIGN BY: REVIEWED BY: DRAWN BY: APPROVED BY: KRM AWDCLS MLP South Coast Center CA6-204 3730 S Bristol St Santa Ana, CA NOTE: THIS LIGHTING PLAN ILLUSTRATES ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA (IESNA) APPROVED METHODS. ACTUAL SITE ILLUMINATION LEVELS AND PERFORMANCE OF LUMINARIES MAY VARY DUE TO VARIATIONS IN WEATHER, ELECTRICAL VOLTAGE, TOLERANCE IN LAMPS AND OTHER RELATED VARIABLE FIELD CONDITIONS. v3 200827 NOTES: 1. READINGS ARE MEASURED AT 36" (3') ABOVE GRADE. N UNIT CALCS 50' Label CalcType Units Avg Max Min Avg/Min Max/Min ALL UNITS 50' @ 36'' Illuminance Fc 5.65 57.1 0.9 6.28 63.44 ATM 4 & 5 50' @ 36'' Illuminance Fc 6.11 24.1 2.1 2.91 11.48 2020-161485 12/15/20 âBank of America E-0 GENERAL NOTES & SCHEDULES Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CA6-204 South Coast Center CA6-204 3730 S Bristol St Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE 1 08/31/2020 CITY COMMENTS Job No.Date 20099-CA6-20407/01/2020 · · LUMINAIRE SCHEDULE **SEE FIXTURE CLARIFICATION NOTE #9 (NP) = NEW POLE (CBO) CONTROLLED BY OTHERS SYMBOL QTY LABEL FIXTURE ARRANGEMENT TOTAL FIXTURE COUNT NEW POLE COUNT FIXTURE TYPE / MOUNTING / MANUFACTURER BUG RATING MOUNTING HEIGHT MOUNTING ACCESSORIES 4 BO1 SINGLE (BO) CPY250-A-DM-F-20W-UL-WH-40K / CANOPY MOUNT / CREE MATCH EXISTING 3 BO2 SINGLE (BO) CPY250-A-DM-F-20W-UL-WH-40K / CANOPY MOUNT / CREE 9' - 6'' AFG 9 DX1 SINGLE (DX) CR6T-825L-40K-12-E26GU24 / CANOPY MOUNT / CREE MATCH EXISTING 6 DX2 SINGLE (DX) CR6T-825L-40K-12-E26GU24 / CANOPY MOUNT / CREE 14' - 9'' AFG 1 DZ1 SINGLE (DZ) CR6T-1600L-40K-12-E26GU24 / CANOPY MOUNT / CREE MATCH EXISTING 2 EK1 SINGLE (EK) ZR22C-40L-40K-10V-FD (LED 2x2) / RECESSED CANOPY MOUNT / CREE MATCH EXISTING 3 SA1 SINGLE (SA) SEC-EDG-2S-WM-02-E-UL-BZ-350-40K / WALL MOUNT / CREE MATCH EXISTING 5 SH1 SINGLE (SH) SEC-EDG-4M-WM-02-E-UL-BZ-350-40K / WALL MOUNT / CREE MATCH EXISTING 2 UU1 SINGLE ALN440-Y5-32LED-4K-700-BL-SLA1 / POLE MOUNT / HUBBELL MATCH EXISTING 3 UU2 (NEW POLE) SINGLE ALN440-Y5-32LED-4K-700-BL-SLA1 / POLE MOUNT / HUBBELL 10' AFG 1 UU3 (NEW POLE) TRIPLE (3@90°) XGBM-FT-LED-LW-NW-UE-BLK / POLE MOUNT / LSI 30' AFG 1 UU4 (NEW POLE) TRIPLE (3@90°) XGBM-FT-LED-SS-NW-UE-BRZ / POLE MOUNT / LSI 30' AFG 1 UU5 (NEW POLE) SINGLE XGBM-FT-LED-HO-NW-UE-BLK / POLE MOUNT / LSI 30' AFG 3 RC1 SINGLE EXISTING FLOOD FIXTURE - 7 RD1 SINGLE EXISTING CANOPY FIXTURE - 3 RE1 SINGLE EXISTING CANOPY FIXTURE - 4 RG1 SINGLE EXISTING CANOPY FIXTURE - 2 XN1 SINGLE BOA DRIVE UP ATM 8' FIXTURE (GEWH9640BAT) - ** CONTRACTOR TO VERIFY MOUNTING ACCESSORIES BEFORE ORDERING** - - - - - - - - - 3 1 1 1 - - - - - 4 3 9 6 1 2 3 5 2 3 3 3 1 3 7 3 4 2 B1-U0-G1 B1-U0-G1 B1-U0-G0 B1-U0-G0 B1-U0-G0 B2-U0-G1 B1-U0-G1 B1-U0-G1 B3-U3-G2 B3-U3-G2 B1-U0-G3 B1-U0-G3 B2-U0-G4 - - - - - XA-BXCC9001 - - - - - - - - GR8 TRIM RING GR8 TRIM RING & REMODEL HOUSING REQUIRED GR8 TRIM RING DGA22-WHT - - - - - TOTAL FIXTURE WATTAGE EXISTING FIXTURE WATTAGE BEING REMOVED/REPLACED 100 100 - - - - - - 100 100 289.1 - 25 25 74.3 400 74.3 - 136.4 - 189 - - 100 100 100 100 11 19.6 32 11 100 - 100 20 20 2020-161485 12/15/20 CALLEN'S COMMON âBank of America Phone (770) 992-5077 ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CA6-204 E-1 SITE PLAN - LIGHTING BLUE GREEN ORANGE = NEW FIXTURE = EXISTING FIXTURE LOCATION TO BE REPLACED = EXISTING FIXTURE TO REMAIN = FIXTURE TO BE REMOVEDTURQUOISE PL = PROPERTY LINE BASED ON COUNTY APPRAISAL INFORMATION PINK = REPLACE WITH NEW POLE AT NEW HEIGHT = INDICATES NEW SECURITY FENCE Professional Engineer CRAIG L. MOLNAR DX1DX1 EK1 EK1 DX1 DX1 DX1 DX1 DX1 DX1 SH1 SA1 BO1 BO1 BO1 BO1 XN1 XN1 SA1 SH1 SH1 DX2 DX2 DX1 DX2 BO2 BO2 BO2 UU2 (NEW POLE) UU2 (NEW POLE) UU1 UU1 UU2 (NEW POLE) SH1 DX2 DX2 DZ1 DX2 SH1 ATM1 ATM3 AHD ATM2 ASSOCIATE ENTRY ATM4 ATM5 PL PL PL PL PL PL PL SA1 UU3 (NEW POLE) UU4 (NEW POLE) UU5 (NEW POLE) NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 NOTE 2 South Coast Center CA6-204 3730 S Bristol St Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE 1 08/31/2020 CITY COMMENTS Job No.Date 20099-CA6-20407/01/2020 2020-161485 12/15/20 âBank of America Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CA6-204 E-2 TITLE 24 DOCUMENTS South Coast Center CA6-204 3730 S Bristol St Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE 1 08/31/2020 CITY COMMENTS Job No.Date 20099-CA6-20407/01/2020 2020-161485 12/15/20 âBank of America Phone (770) 992-5077 Professional Engineer CRAIG L. MOLNAR ROSWELL, GA 30075 10927 CRABAPPLE RD Fax (770) 992-7593 20099-CA6-204 E-3 TITLE 24 DOCUMENTS South Coast Center CA6-204 3730 S Bristol St Santa Ana, CA DESCRIPTIONREVISION NO. REVISION DATE 1 08/31/2020 CITY COMMENTS Job No.Date 20099-CA6-20407/01/2020 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 CR6T 12 E26GU24 Series Initial Delivered Lumens CCT Voltage Base Type CR6T 6" (152mm) 825L 11W, 825 Lumens - 75 LPW 1100L 14.5W, 1100 Lumens - 76 LPW 1600L 21W, 1600 Lumens - 76 LPW 27K 2700K 30K 3000K 35K 3500K 40K 4000K 12 120 Volts E26GU24 Includes E26 (Title 20 Compliant) and GU24 Base Pigtail (Title 24 Compliant) Ordering Information Example: CR6T-825L-27K-12-E26GU24 3.5" (90mm)2.3" (59mm) Ø7.4" (Ø188mm) Ø5.3" (Ø135mm) CRT Series CR6T LED Downlight - 6" (152mm) Product Description The new CR6T LED downlight delivers up to 1,600 lumens while achieving over 75 lumens per watt. This breakthrough performance is achieved by combining the high efficacy and high-quality 90 CRI light. The CR6T is available in warm and cool color temperatures, and easily installs into most standard five-inch or six-inch recessed IC or non-IC housings. Applications: New construction or upgrade for residential and commercial lighting Initial Delivered Lumens: 825 Lumens, 1,100 Lumens, 1,600 Lumens Input Power: 11 watts, 14.5 watts, 21 watts CRI: 90+ CCT : 2700K, 3000K, 3500K, 4000K Limited Warranty† : 5 years Lifetime: Designed to last 50,000 hours Dimming: Dimmable to 5% Rated for Dry, Damp, and Wet Locations Performance Summary † See http://lighting.cree.com/warranty for warranty terms Ordering Number Single-Carton UPC Single Cartons Per Master Carton Master Carton ITF-14 Watts CCT Lumens Rated Life (Hrs) CR6T-825L-27K-12-E26GU24 849665023487 12 10849665023484 11 2700K 825 50,000 CR6T-825L-30K-12-E26GU24 849665023494 12 10849665023491 11 3000K 825 50,000 CR6T-825L-35K-12-E26GU24 849665023500 12 10849665023507 11 3500K 825 50,000 CR6T-825L-40K-12-E26GU24 849665023517 12 10849665023514 11 4000K 825 50,000 CR6T-1100L-27K-12-E26GU24 849665023425 12 10849665023422 14.5 2700K 1,100 50,000 CR6T-1100L-30K-12-E26GU24 849665023432 12 10849665023439 14.5 3000K 1,100 50,000 CR6T-1100L-35K-12-E26GU24 849665025412 12 10849665025419 14.5 3500K 1,100 50,000 CR6T-1100L-40K-12-E26GU24 849665023449 12 10849665023446 14.5 4000K 1,100 50,000 CR6T-1600L-27K-12-E26GU24 849665023456 12 10849665023453 21 2700K 1,600 50,000 CR6T-1600L-30K-12-E26GU24 849665023463 12 10849665023460 21 3000K 1,600 50,000 CR6T-1600L-35K-12-E26GU24 849665025429 12 10849665025426 21 3500K 1,600 50,000 CR6T-1600L-40K-12-E26GU24 849665023470 12 10849665023477 21 4000K 1,600 50,000 Accessories Field-Installed Trims CR6T-TRMBRAN-1 - 6" (152mm) Plastic Reflector Trim - Bronze CR6T-TRMBKAN-1 - 6" (152mm) Plastic Reflector Trim - Black CR6T-TRMSTAN-1 - 6” (152mm) Plastic Reflector Trim - Satin Nickel CR6T-TRMBKBB-1 - 6” (152mm) Plastic Reflector Trim w/Extended Flange - Black 8" Adapter Ring GR8 - Optional goof ring accommodates existing housings with apertures from 6.25” (159mm) to 8.5” (216mm) in diameter Housings Refer to page three for details. T (800) 236-6800 F (262) 504-5415 US: lighting.cree.com T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Rev. Date: V3 04/02/2019 825L 40K TYPE DX CR6T-825L-40K-12-E25GU24 GC TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION PRIOR TO PURCHASING CONTRACTOR TO DESIGNATE GC TO VERIFY AND SPECIFY IF NOT 120v MUST BE GU24-E26 IN CA CR6T-825L-40K-12-E25GU24 2020-161485 12/15/20 T (800) 236-6800 F (262) 504-5415 US: lighting.cree.com T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Reference https://lighting.cree.com/products/indoor/retrofit-downlights/crt-series for detailed photometric data Photometry CR6T-1100L-27K BASED ON CESTL REPORT TEST #: PL13053-001A Luminaire photometry has been conducted in accordance with IESNA LM-79-08. IESNA LM-79-08 specifies the entire luminaire as the source resulting in a luminaire efficiency of 100%. NOTE: Reference https://lighting.cree.com/products/indoor/retrofit-downlights/crt-series for detailed installation instructions 0˚ 20˚ 50˚ 70˚ 90˚ 135 0 542 271 406 0˚ 90˚ Product Specifications CONSTRUCTION & MATERIALS • Durable upper housing protects LEDs, driver and power supply. Adjustable flip clips resist heat while providing retention for flush ceiling fit • Thermal management system uses both upper housing and lower reflector to conduct heat away from LEDs and transfer it to the plenum space for optimal performance. LED junction temperatures stay below specified maximum even when installed in insulated ceilings • Suitable for insulated and non-insulated ceilings • One-piece aluminum lower reflector redirects light while also conducting heat away from LEDs. It creates a comfortable visual transition from the lens to the ceiling plane and easily accommodates CRT6 snap-in trims OPTICAL SYSTEM • Unique combination of reflective and refractive optical components achieves a uniform, comfortable appearance while eliminating pixelation and color fringing. This ensures smooth light patterns are projected with no hot spots and minimal striations • Components work together to optimize distribution, balancing the delivery of high illuminance levels on horizontal surfaces with an ideal amount of light on walls and vertical surfaces. This increases the perception of spaciousness • Diffusing polycarbonate lens shields direct view of LEDs while lower reflector balances brightness of lens with the ceiling to create a low-glare high angle appearance ELECTRICAL SYSTEM • Integral, high-efficiency power supply • Power Factor: > 0.9 • Total Harmonic Distortion: < 20% • Input Voltage: 120V, 50/60Hz • Dimming: Dimmable to 5% with select incandescent dimmers. Forward phase (triac) and reverse phase dimming only. • Reference http://lighting.cree.com/products/indoor/retrofit-downlights/crt-series for recommended dimmers • Use only lighting controls with neutral connection or controls intended for use with LED fixtures • Operating Temperature Range: -25˚C to +35˚C (-13˚F - +95˚F) REGULATORY & VOLUNTARY QUALIFICATIONS • cULus Classified • Suitable for wet locations for covered ceilings only • Meets FCC Part 15, Subpart B, Class B standards for conducted and radiated emissions • ENERGY STAR ® certified. Please refer to https://www.energystar.gov/productfinder/product/certified-light- fixtures/results for most current information • Meets California Title 20/Title 24 high efficiency luminaire requirements • RoHS Compliant. Consult factory for additional details • CA RESIDENTS WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov Zonal Lumen Summary Zone Lumens % Lamp Luminaire 0-30 418 N/A 34.6% 0-40 673 N/A 55.7% 0-60 1069 N/A 88.5% 0-90 1209 N/A 100.0% 0-180 1209 N/A 100.0% Average Luminance Table (cd/m2) Ve r t i c a l A n g l e Horizontal Angle 0˚ 45˚ 90˚ 45˚ 26,004 26,188 26,575 55˚ 19,609 19,685 19,880 65˚ 13,263 13,248 13,366 75˚ 8,283 8,211 8,235 85˚ 7,130 6,773 6,702 Coefficients Of Utilization – Zonal Cavity Method RC %: 80 RW %: 70 50 30 10 RCR: 0 119 119 119 119 1 110 106 103 99 2 102 95 89 84 3 94 84 77 71 4 87 76 68 62 5 80 68 60 54 6 74 62 54 48 7 69 57 48 43 8 65 52 44 38 9 60 48 40 35 10 57 44 37 32 Effective Floor Cavity Reflectance: 20% Installation • Designed easily to install in standard 5-6” (127mm - 152mm) downlight housings with minimum housing height of 5.5” (140mm) and diameter 5.5” to 6.5” (140mm - 165mm) • Quick install system utilizes a unique retention feature. Simply attach socket to CR6T. Move light to ready position and slide into housing CR6T LED Downlight - 6" (152mm) 2020-161485 12/15/20 © 2019 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. Patent www.cree.com/patents. Cree® and the Cree logo are registered trademarks of Cree, Inc. ENERGY STAR ® and the ENERGY STAR logo are registered trademarks of the U.S. Environmental Protection Agency. The UL logo is a registered trademark of UL LLC. T (800) 236-6800 F (262) 504-5415 US: lighting.cree.com T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Housings - Reference Housing spec sheets for additional details Edison (E26) Base Housings Recessed Housings, 120V RC6 - New construction RR6 - Retrofit Recessed “Pan” Conversion Kit, 120V C6 Surface Mount Housings, 120V SC6 - Textured white finish SC6-BL - Textured black finish Cord Mount Housings, 120V SC6-CM - Textured white finish - Includes 5" (127mm) canopy and 7' (2.1m) white cord SC6-CM-BL - Textured black finish - Includes 5" (127mm) canopy and 7' (2.1m) black cord GU24 Base Housings Recessed Housings, 120V H6-GU24 - Architectural new construction RC6-GU24 - New construction RR6-GU24 - Retrofit Recessed “Pan” Conversion Kit, 120V C6-GU24 C6-120V-LSA - Less socket adapter Surface Mount Housings, 120V SC6-GU24 - Textured white finish SC6-BL-GU24 - Textured black finish Cord Mount Housings, 120V SC6-CM-GU24 - Textured white finish - Includes 5" (127mm) canopy and 7' (2.1m) white cord SC6-CM-BL-GU24 - Textured black finish - Includes 5" (127mm) canopy and 7' (2.1m) black cord Wall Mount Housings, 120V SC6-WM-GU24 - Textured white finish SC6-WM-BL-GU24 - Textured black finish CR6T LED Downlight - 6" (152mm) Open Space Spacing Lumens Wattage LPW w/ft2 Average FC 4 x 4 825 11 75 0.66 48 6 x 6 0.30 22 8 x 8 0.16 12 10 x 10 0.11 8 4 x 4 1,100 14.5 76 0.87 64 6 x 6 0.40 30 8 x 8 0.21 16 10 x 10 0.14 10 4 x 4 1,600 21 76 1.26 94 6 x 6 0.58 44 8 x 8 0.31 23 10 x 10 0.21 15 10' Ceiling, 80/50/20 Reflectances, 2.5 workplane. LLF: 1.0 Initial. Open Space: 50' x 40' x 10' Corridor Spacing Lumens Wattage LPW w/ft2 Average FC 4' on Center 825 11 75 0.45 16 6' on Center 0.31 11 8' on Center 0.22 8 10' on Center 0.18 6 4' on Center 1,100 14.5 76 0.60 22 6' on Center 0.41 15 8' on Center 0.29 10 10' on Center 0.24 9 4' on Center 1,600 21 76 0.87 32 6' on Center 0.60 22 8' on Center 0.42 15 10' on Center 0.35 13 10' Ceiling, 80/50/20 Reflectances, Light levels on the ground. LLF: 1.0 Initial. Corridor: 6' Wide x 100' Long Application Reference 2020-161485 12/15/20 CR6T 12 E26GU24 Series Initial Delivered Lumens CCT Voltage Base Type CR6T 6" (152mm) 825L 11W, 825 Lumens - 75 LPW 1100L 14.5W, 1100 Lumens - 76 LPW 1600L 21W, 1600 Lumens - 76 LPW 27K 2700K 30K 3000K 35K 3500K 40K 4000K 12 120 Volts E26GU24 Includes E26 (Title 20 Compliant) and GU24 Base Pigtail (Title 24 Compliant) Ordering Information Example: CR6T-825L-27K-12-E26GU24 3.5" (90mm)2.3" (59mm) Ø7.4" (Ø188mm) Ø5.3" (Ø135mm) CRT Series CR6T LED Downlight - 6" (152mm) Product Description Initial Delivered Lumens: 825 Lumens, 1,100 Lumens, 1,600 Lumens Input Power: 11 watts, 14.5 watts, 21 watts CRI: 90+ CCT : 2700K, 3000K, 3500K, 4000K Limited Warranty† : 5 years Lifetime: Designed to last 50,000 hours Dimming: Dimmable to 5% Rated for Dry, Damp, and Wet Locations Performance Summary † See http://lighting.cree.com/warranty for warranty terms Ordering Number Single-Carton UPC Single Cartons Per Master Carton Master Carton ITF-14 Watts CCT Lumens Rated Life (Hrs) CR6T-825L-27K-12-E26GU24 849665023487 12 10849665023484 11 2700K 825 50,000 CR6T-825L-30K-12-E26GU24 849665023494 12 10849665023491 11 3000K 825 50,000 CR6T-825L-35K-12-E26GU24 849665023500 12 10849665023507 11 3500K 825 50,000 CR6T-825L-40K-12-E26GU24 849665023517 12 10849665023514 11 4000K 825 50,000 CR6T-1100L-27K-12-E26GU24 849665023425 12 10849665023422 14.5 2700K 1,100 50,000 CR6T-1100L-30K-12-E26GU24 849665023432 12 10849665023439 14.5 3000K 1,100 50,000 CR6T-1100L-35K-12-E26GU24 849665025412 12 10849665025419 14.5 3500K 1,100 50,000 CR6T-1100L-40K-12-E26GU24 849665023449 12 10849665023446 14.5 4000K 1,100 50,000 CR6T-1600L-27K-12-E26GU24 849665023456 12 10849665023453 21 2700K 1,600 50,000 CR6T-1600L-30K-12-E26GU24 849665023463 12 10849665023460 21 3000K 1,600 50,000 CR6T-1600L-35K-12-E26GU24 849665025429 12 10849665025426 21 3500K 1,600 50,000 CR6T-1600L-40K-12-E26GU24 849665023470 12 10849665023477 21 4000K 1,600 50,000 Accessories Field-Installed Trims CR6T-TRMBRAN-1 - 6" (152mm) Plastic Reflector Trim - Bronze CR6T-TRMBKAN-1 - 6" (152mm) Plastic Reflector Trim - Black CR6T-TRMSTAN-1 - 6” (152mm) Plastic Reflector Trim - Satin Nickel CR6T-TRMBKBB-1 - 6” (152mm) Plastic Reflector Trim w/Extended Flange - Black 8" Adapter Ring GR8 - Optional goof ring accommodates existing housings with apertures from 6.25” (159mm) to 8.5” (216mm) in diameter Housings Refer to page three for details. T (800) 236-6800 F (262) 504-5415 US: lighting.cree.com T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Rev. Date: V3 04/02/2019 The new CR6T LED downlight delivers up to 1,600 lumens while achieving over 75 lumens per watt. This breakthrough performance is achieved by combining the high efficacy and high-quality 90 CRI light. The CR6T is available in warm and cool color temperatures, and easily installs into most standard five-inch or six-inch recessed IC or non-IC housings. Applications: New construction or upgrade for residential and commercial lighting 825L 40K TYPE DZ CR6T-1600L-40K-12-E25GU24 GC TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION PRIOR TO PURCHASING CONTRACTOR TO DESIGNATE GC TO VERIFY AND SPECIFY IF NOT 120v MUST BE GU24-E26 IN CA 2020-161485 12/15/20 T (800) 236-6800 F (262) 504-5415 US: lighting.cree.com T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Reference https://lighting.cree.com/products/indoor/retrofit-downlights/crt-series for detailed photometric data Photometry CR6T-1100L-27K BASED ON CESTL REPORT TEST #: PL13053-001A Luminaire photometry has been conducted in accordance with IESNA LM-79-08. IESNA LM-79-08 specifies the entire luminaire as the source resulting in a luminaire efficiency of 100%. NOTE: Reference https://lighting.cree.com/products/indoor/retrofit-downlights/crt-series for detailed installation instructions 0˚ 20˚ 50˚ 70˚ 90˚ 135 0 542 271 406 0˚ 90˚ Product Specifications CONSTRUCTION & MATERIALS • Durable upper housing protects LEDs, driver and power supply. Adjustable flip clips resist heat while providing retention for flush ceiling fit • Thermal management system uses both upper housing and lower reflector to conduct heat away from LEDs and transfer it to the plenum space for optimal performance. LED junction temperatures stay below specified maximum even when installed in insulated ceilings • Suitable for insulated and non-insulated ceilings • One-piece aluminum lower reflector redirects light while also conducting heat away from LEDs. It creates a comfortable visual transition from the lens to the ceiling plane and easily accommodates CRT6 snap-in trims OPTICAL SYSTEM • Unique combination of reflective and refractive optical components achieves a uniform, comfortable appearance while eliminating pixelation and color fringing. This ensures smooth light patterns are projected with no hot spots and minimal striations • Components work together to optimize distribution, balancing the delivery of high illuminance levels on horizontal surfaces with an ideal amount of light on walls and vertical surfaces. This increases the perception of spaciousness • Diffusing polycarbonate lens shields direct view of LEDs while lower reflector balances brightness of lens with the ceiling to create a low-glare high angle appearance ELECTRICAL SYSTEM • Integral, high-efficiency power supply • Power Factor: > 0.9 • Total Harmonic Distortion: < 20% • Input Voltage: 120V, 50/60Hz • Dimming: Dimmable to 5% with select incandescent dimmers. Forward phase (triac) and reverse phase dimming only. • Reference http://lighting.cree.com/products/indoor/retrofit-downlights/crt-series for recommended dimmers • Use only lighting controls with neutral connection or controls intended for use with LED fixtures • Operating Temperature Range: -25˚C to +35˚C (-13˚F - +95˚F) REGULATORY & VOLUNTARY QUALIFICATIONS • cULus Classified • Suitable for wet locations for covered ceilings only • Meets FCC Part 15, Subpart B, Class B standards for conducted and radiated emissions • ENERGY STAR ® certified. Please refer to https://www.energystar.gov/productfinder/product/certified-light- fixtures/results for most current information • Meets California Title 20/Title 24 high efficiency luminaire requirements • RoHS Compliant. Consult factory for additional details • CA RESIDENTS WARNING: Cancer and Reproductive Harm – www.p65warnings.ca.gov Zonal Lumen Summary Zone Lumens % Lamp Luminaire 0-30 418 N/A 34.6% 0-40 673 N/A 55.7% 0-60 1069 N/A 88.5% 0-90 1209 N/A 100.0% 0-180 1209 N/A 100.0% Average Luminance Table (cd/m2) Ve r t i c a l A n g l e Horizontal Angle 0˚ 45˚ 90˚ 45˚ 26,004 26,188 26,575 55˚ 19,609 19,685 19,880 65˚ 13,263 13,248 13,366 75˚ 8,283 8,211 8,235 85˚ 7,130 6,773 6,702 Coefficients Of Utilization – Zonal Cavity Method RC %: 80 RW %: 70 50 30 10 RCR: 0 119 119 119 119 1 110 106 103 99 2 102 95 89 84 3 94 84 77 71 4 87 76 68 62 5 80 68 60 54 6 74 62 54 48 7 69 57 48 43 8 65 52 44 38 9 60 48 40 35 10 57 44 37 32 Effective Floor Cavity Reflectance: 20% Installation • Designed easily to install in standard 5-6” (127mm - 152mm) downlight housings with minimum housing height of 5.5” (140mm) and diameter 5.5” to 6.5” (140mm - 165mm) • Quick install system utilizes a unique retention feature. Simply attach socket to CR6T. Move light to ready position and slide into housing CR6T LED Downlight - 6" (152mm) 2020-161485 12/15/20 © 2019 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. Patent www.cree.com/patents. Cree® and the Cree logo are registered trademarks of Cree, Inc. ENERGY STAR ® and the ENERGY STAR logo are registered trademarks of the U.S. Environmental Protection Agency. The UL logo is a registered trademark of UL LLC. T (800) 236-6800 F (262) 504-5415 US: lighting.cree.com T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada Housings - Reference Housing spec sheets for additional details Edison (E26) Base Housings Recessed Housings, 120V RC6 - New construction RR6 - Retrofit Recessed “Pan” Conversion Kit, 120V C6 Surface Mount Housings, 120V SC6 - Textured white finish SC6-BL - Textured black finish Cord Mount Housings, 120V SC6-CM - Textured white finish - Includes 5" (127mm) canopy and 7' (2.1m) white cord SC6-CM-BL - Textured black finish - Includes 5" (127mm) canopy and 7' (2.1m) black cord GU24 Base Housings Recessed Housings, 120V H6-GU24 - Architectural new construction RC6-GU24 - New construction RR6-GU24 - Retrofit Recessed “Pan” Conversion Kit, 120V C6-GU24 C6-120V-LSA - Less socket adapter Surface Mount Housings, 120V SC6-GU24 - Textured white finish SC6-BL-GU24 - Textured black finish Cord Mount Housings, 120V SC6-CM-GU24 - Textured white finish - Includes 5" (127mm) canopy and 7' (2.1m) white cord SC6-CM-BL-GU24 - Textured black finish - Includes 5" (127mm) canopy and 7' (2.1m) black cord Wall Mount Housings, 120V SC6-WM-GU24 - Textured white finish SC6-WM-BL-GU24 - Textured black finish CR6T LED Downlight - 6" (152mm) Open Space Spacing Lumens Wattage LPW w/ft2 Average FC 4 x 4 825 11 75 0.66 48 6 x 6 0.30 22 8 x 8 0.16 12 10 x 10 0.11 8 4 x 4 1,100 14.5 76 0.87 64 6 x 6 0.40 30 8 x 8 0.21 16 10 x 10 0.14 10 4 x 4 1,600 21 76 1.26 94 6 x 6 0.58 44 8 x 8 0.31 23 10 x 10 0.21 15 10' Ceiling, 80/50/20 Reflectances, 2.5 workplane. LLF: 1.0 Initial. Open Space: 50' x 40' x 10' Corridor Spacing Lumens Wattage LPW w/ft2 Average FC 4' on Center 825 11 75 0.45 16 6' on Center 0.31 11 8' on Center 0.22 8 10' on Center 0.18 6 4' on Center 1,100 14.5 76 0.60 22 6' on Center 0.41 15 8' on Center 0.29 10 10' on Center 0.24 9 4' on Center 1,600 21 76 0.87 32 6' on Center 0.60 22 8' on Center 0.42 15 10' on Center 0.35 13 10' Ceiling, 80/50/20 Reflectances, Light levels on the ground. LLF: 1.0 Initial. Corridor: 6' Wide x 100' Long Application Reference 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 2020-161485 12/15/20 | 1 | ALN440 Towne Commons® LED TYPE ARCHITECTURAL AREA LIGHTING 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.aal.net Copyright © 2014 May 9, 2017 3:09 PM 1. LUMI- NAIRE 2. DISTRIBUTION 3. COLOR TEMP 4. DRIVER 5. COLOR 6. OPTIONS 7. CONTROL 8. MOUNTING Energy Saving LED technology Reliable effi cient operation Type 2, 3, 4, 5 distributions 0-10V dimming ready LifeShield® protection system Surge protection included Wide variety of custom mounting options including post-top, wall mount or pole mount arm IP66 construction of optical system Cast aluminum struts DLC pending 1. LUMINAIRE ARM OR POST TOP MOUNT ALN 440 TOP MOUNTED ARM OR PENDANT MOUNT ALN 440D 2. DISTRIBUTION Y2 (Type 2) Y3 (Type 3) Y4 (Type 4) Y5 (Type 5) 3. COLOR TEMPERATURE 32LED-3K (Warm White, 3000K output) 32LED-4K (Neutral White, 4000K output) 32LED-5K (Bright White, 5000K output) 4. DRIVER (120 thru 277 volt) 700 (700mA drive current, 75 watts) SPECIFICATIONS HOUSING Luminaire shall be cast A356 alloy aluminum, free of any porosity or cosmetic fi llers. Castings shall be of uniform wall thickness, minimum .188 inch with no warping or mold shifting. The top cap shall hinge open by loosening two captive fasteners. The top shall seal the lamp compartment with a continuous silicone gasket. The lens shall be one-piece clear optical grade acrylic with a one-piece memory retentive silicone gasket on top and bottom. The LED and driver assembly shall be serviceable by backing out three thumb screws to allow for the light engine to be lifted out. Quick disconnects shall be used for all electrical connections. All internal and external hardware shall be stainless steel. OPTICAL MODULE The optical assembly shall be completely sealed with a one piece injection molded silicone gasket to prevent dust, insect or moisture contamination. The optical array shall consist of high brightness light emitting diodes mounted to a printed metal circuit board with precision injection molded optically clear lenses discretely coupled to each individual diode. The printed circuit board assembly shall have a uniform conformal coating with the exception of the optical output lens at each diode and be mechanically fastened to an anodized die-cast aluminum heat sink. Standard color temperatures shall be 3000K, 4000K and 5000K. ELECTRICAL All Luminaires shall accept 120 thru 277 volt input and have integral surge protection. Drivers shall be U.L recognized and have a 0-10v dimming interface with a dimming range of 10-100%. Approved dimmers include Lutron Diva AVTV, Lutron Nova NFTV and NTFTV. (Note: not compatible with current sourcing dimmers). Consult factory for current list of known compatible dimming systems. LifeShield shall be provided with all confi gurations for added protection in extreme temperature environments (-30°C to 60°C). The electrical assembly shall be mounted to a serviceable tray. The surge protector shall be U.L. recognized and have a sur ge current rating of 10,000 Amps using the industry standard 8/20uSec wave with a clamping voltage of 320V and surge rating of 372J. ALN440 7. CONTROL PCA-C (Contemporary photocell adapter, not for Wall Mount) PCA-T (Traditional photocell adapter, not for Wall Mount) SCP (Sensor Control Programmable) pole accessory is available to provide occupancy detection for outdoor applications meeting California Title 24. For complete spec sheet and ordering information, visit www.aal.net/ products/sensor_control_programmable/ 8. MOUNTING WALL MOUNT ALN440 WMA1M WMA1L WMA3 WMA35U WMA36U WMA55 WMA56 WMA57 WMA7 WMA9U WMA22U ALN440D WMA2M WMA2L WMA37 WMA38 WMA39 WMA4 WMA6 WMA8 WMA9D WMA10 WMA11 WMA12 WMA16 WMA17 WMA18 WMA22D POLE MOUNT Post Top Mount: (Standard) The fi xture shall slip over a 4"/100mm O.D. pole or tenon and be secured to the pole with three (or six) stainless steel set screws. Pole Side Mount (4" O.D. or 5" O.D. side mount) ALN440 TRA1M TRA3 TRA5U TRA55 TRA56 (4 only) TRA57 TRA59U SLA8U SLA22U ALN440D TRA2M TRA2L SLA3 (4 only) SLA8D SLA22D Pole Top Mount Arm ALN440 SLA1 SLA1-2 ALN440D TRA4 TRA7 TRA7-2 TRA8 TRA9 TRA9-2 SLA4 SLA4-2 SLA7 SLA7-2 SLA9 SLA9-2 SLA10 SLA10-2 SLA16 SLA16-2 SLA17 SLA17-2 SLA18 SLA18-2 PIER MOUNT PM1 PM2 PM3 See next page JOB TYPE NOTES Visit www.aal.net for Arms, Poles & Accessories Specification Guide ALN 440 Available in 3000K, 4000K and 5000K Powder coat fi nish in 13 standard colors with polymer sealer 6. OPTIONS CHM (Glass chimney with polished brass holder) CND (3-lamp candelabra with polished brass holder, lamps included. For decorative use only.) LDL (Lightly diffused lens) SBL (Sandblast diffused lens) HSS-L (House side shield, consists of three field installed panels attached to the inside of the lens. Installing three panels blocks 180° of the lens) MAT (Mast arm adapter slips over a 2 3/8 / 60mm O.D. pipe and is secured with 4 stainless steel set screws. For ALN440D only.) PMS (Pendant mount with 48 / 1220mm stem and canopy with swivel. For ALN440D only.) PMC (Pendant kit includes canopy and 48 / 1220mm of brass chain painted the fixture color. For ALN440D only.) PT5 (Post top adaptor for a 5/127mm O.D. pole) 5. COLOR WH Arctic White BL Black BLT Matte Black DB Dark Bronze DGN Dark Green TT Titanium WDB Weathered Bronze MDB Bronze Metallic VBU Verde Blue CRT Corten MAL Matte Aluminum MG Medium Grey AGN Antique Green LG Light Grey RAL Premium Color CUSTOM * * Contact Factory UU 1-2 ALN440-Y5-32LED-4K-700-BL-SLA 1 GC TO VERIFY AND SPECIFY IF NOT UE GC TO REFERENCE PLANS FOR COLOR DESIGNATION UU 1-2 ALN440-Y5-32LED-4K-700-BL-SLA 1 GC TO VERIFY AND SPECIFY IF NOT UE GC TO REFERENCE PLANS FOR COLOR DESIGNATION 2020-161485 12/15/20 | 2 | ALN440 Towne Commons® LED TYPE ARCHITECTURAL AREA LIGHTING 17760 Rowland Street | City of Industry | CA 91748 P 626.968.5666 | F 626.369.2695 | www.aal.net Copyright © 2014 May 9, 2017 3:09 PM The surge protector case shall be a high-temperature, flame resistant plastic enclosure. The electrical assembly shall be installed and prewired in the fixture. CONTROLS SCP shall have an integral surge protection device with a currentt rating of 10,000 Amps using the industry standard 8/20uSec wave and sure rating of 372J Sensor not intended for use with additional photo- control, wireless control or dimming systems. SERVICING The top of the fixture shall hinge open for relamping by loosening two stainless steel fasteners. MOUNTING Post top mounting: The fixture shall slip over a 4"/100mm O.D. pole or tenon and be secured to the pole with three (or six) stainless steel set screws. Arm or wall mounting: The fixture shall be attached to the cast arm with three stainless steel bolts and a silicone gasket. FINISH Fixture finish shall consist of a five stage pretreatment regimen with a polymer primer sealer, oven dry off and top coated with a thermoset super TGIC polyester powder coat finish. The finish shall meet the AAMA 2604-02 performance specification which includes passing a 3000 hour salt spray test for corrosion resistance. CERTIFICATION Fixtures shall be listed with ETL for outdoor, wet location use, conforming to the UL 1598 and Canadian CSA 22.2 no. 250 standard. IP54. WARRANTY / TERMS AND CONDITIONS OF SALE Download: http://www.hubbelllighting.com/resources/warranty/ ALN440-Y3-32LED-5K-700 WATTAGE: 75 LUMEN OUTPUT: 5237 EFFICACY: 70 Lm/W 14' MOUNTING HEIGHT B2 U3 G2 FORWARD LIGHT LUMEN FL 30o 2.4% 124.3 FM 60o 34.5% 1804.4 FH 80o 29.1% 1523.6 FVH 90o 3.1% 163.2 BACK LIGHT BL 30o 1.7% 90.7 BM 60o 12.1% 631.5 BH 80o 11.1% 582.8 BVH 90o 2.5% 133.1 UPLIGHT UL 100o 1.0% 54.3 UH 180o 2.5% 129.2 ALN440-Y5-32LED-5K-700 WATTAGE: 74.9 LUMEN OUTPUT: 5183 EFFICACY: 69 Lm/W 14' MOUNTING HEIGHT B3 U3 G3 FORWARD LIGHT LUMEN FL 30o 1.9% 96.7 FM 60o 16.2% 839.4 FH 80o 25.8% 1336.3 FVH 90o 4.4% 228.3 BACK LIGHT BL 30o 1.9% 96.7 BM 60o 16.2% 839.4 BH 80o 25.8% 1336.3 BVH 90o 4.4% 228.3 UPLIGHT UL 100o 1.6% 82.2 UH 180o 1.9% 99.0 IES files can be found at www.aal.net DIMENSIONS ALN440 ALN440D HEIGHT: 26/660mm LENGTH: 18/460mm WIDTH: 18/460mm WEIGHT: 35 lbs. EPA: 2.59 ALN440 HEIGHT: 31/790mm LENGTH: 18/460mm WIDTH: 18/460mm WEIGHT: 40 lbs. EPA: 2.80 PERFORMANCE DATA (32 LEDS, 700 MA DRIVE CURRENT, 75 WATTS) ALN440 ALN440D AAL reserves the right to change product specifications without notice. AMBIENT TEMP. 0 25,000 50,000 *TM-21-11 60,000 100,000 PROJECTED L70 (HRS) 25°C/ 77°F 100% 95% 93% 92% 89% >60,000 40°C/ 104°F 100% 94% 91% 90% 85% >60,000 PROJECTED LUMEN MAINTENANCE ALN440-Y5-32LED-5K-700 ALN440-Y5-32LED-5K-700 TYPE LENS 5K 4K 3K LUMENS LPW B U G LUMENS LPW B U G LUMENS LPW B U G Y2 CLEAR 5427 72 2 3 3 5156 69 2 2 3 4016 54 1 3 2 Y3 5237 70 2 3 2 4975 66 2 3 2 3875 52 1 3 2 Y4 5736 76 1 3 3 5449 73 1 3 3 4245 57 1 3 2 Y5 5183 69 3 3 3 4945 66 3 3 2 3809 51 2 3 2 Y2 LDL 5160 69 2 4 3 4902 65 2 4 3 3818 51 1 3 3 Y3 4964 66 1 4 3 4716 63 1 4 3 3674 49 1 3 3 Y4 5449 73 1 4 3 5176 69 1 4 3 4032 54 1 4 3 Y5 4901 65 2 4 3 4685 62 2 4 3 3610 48 2 3 3 Y2 SBL 4729 63 2 4 3 4492 60 1 4 3 3499 47 1 4 3 Y3 4554 61 1 4 3 4327 58 1 4 3 3370 45 1 4 2 Y4 5004 67 1 4 3 4754 63 1 4 3 3703 49 1 4 3 Y5 4499 60 2 4 3 4292 57 2 4 3 3310 44 1 4 2 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 DOE LIGHTING FACTS Department of Energy has verified representative product test data and results in accordance with its Lighting Facts Program. Visit www.lightingfacts.com for specific catalog strings. SMARTTEC™ THERMAL CONTROL - LSI drivers feature integral sensor which reduces drive current when ambient temperatures exceed rated temperature. OCCUPANCY SENSING (IMS) – Optional integral passive infrared motion sensor activates switching of luminaire light levels. High level light is activated and increased to full bright in 1-2 seconds upon detection of motion. Low light level (30% maximum drive current) is activated when target zone is absent of motion activity for ~2 minutes and ramps down (10-15 seconds) to low level to allow eyes time to adjust. Sensor is located on the front of optical assembly and rotates with the optic. Sensor optic has a detection cone of approximately 45°. Examples of detection – occurs 30' out from a 30' mounting height pole; occurs 20' out from a 20' mounting height pole. ENERGY SAVING CONTROL OPTIONS – DIM – 0-10 volt dimming enabled with controls by others. BLS – Bi-level switching responds to external line voltage signal from separate 120-277V controller or sensor (by others), with low light level decreased to 30% maximum drive current. LEDS - Select high-brightness LEDs in Cool White (5000K) or Neutral White (4000K) color temperature, 70 CRI. DISTRIBUTION/PERFORMANCE - Types 3, 5, FT and FTA available - field rotatable reflectors. HOUSING - Square, die-formed aluminum. Fully enclosed weather-tight housing contains factory prewired drivers and field connections. TOP-ACCESS COVER - Gasketed, tethered top-access cover provides ease of installation and allows for easy driver access. Four captive stainless-steel fasteners secure the top- access cover to the housing. OPTICAL UNIT - Clear tempered optical grade flat glass lens sealed to aluminum housing creates an IP67 rated, sealed optical unit (includes pressure stabilizing breather). Optical unit can be easily field rotated in 90o increments. Directional arrow on optics allows alignment without the unit being energized. MOUNTING - 2-1/2” x 5-3/8” x 12” extruded aluminum arm mounting bracket shipped standard. Use with 5” traditional drilling pattern. Round Pole Plate (RPP2) required for mounting to 3”– 5” round poles. (See Accessory Ordering Information chart.) ELECTRICAL - Two-stage surge protection (including separate surge protection built into electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal voltage power supply 120-277VAC (UE - 50/60Hz input), and 347-480VAC. DRIVERS - Available in Low Watt (LW), Super Saver (SS) and High Output (HO) drive currents (Drive currents are factory programmed). Components are fully encased in potting material for moisture resistance. Driver complies with FCC 47 CFR part 15 RFI/EMI standard. OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F). FINISH - Fixtures are finished with LSI's DuraGrip ® polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling. DECAL STRIPING - LSI offers optional color-coordinated decals in 9 standard colors to accent the fixture. Decals are guaranteed for five years against peeling, cracking, or fading. WARRANTY - LSI LED fixtures carry a limited 5-year warranty. PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed photometric data. SHIPPING WEIGHT (IN CARTON) - Fixture - 44.5 lbs (20 kg) Arm - 5 lbs. (2kg) arm LISTING - UL listed to U.S. and Canadian safety standards. Suitable for wet locations. For a list of the specific products in this series that are DLC listed, please consult the LED Lighting section of our website or the Design Lights website at www.designlights.org. LED AREA LIGHTS - (XGBM) US patent D574994 & 7,828,456 and MX patent 29631 and US & Int'l. patents pending Type 3 Type 5 Type FT Type FTA LIGHT OUTPUT - XGBM Lumens (Nominal) Watts (Nominal) LW 14080 13840 15020 16560 140 SS 20180 18040 20700 23030 187 HO 26750 25460 29070 31810 300 LW 11450 11290 12220 13470 136 SS 16390 15170 17230 18750 188 HO 22240 20550 23510 25410 288 Co o l W h i t e Ne u t r a l W h i t e LED Chips are frequently updated therefore values may increase. Shown with optional decal striping This product, or selected versions of this product, meet the standards listed below. Please consult factory for your specific requirements. wet location ARRA Funding Compliant IP67 Fixtures comply with ANSI C136.31-2010 American National Standard for Roadway Lighting Equipment - Luminaire Vibration 3G requirements. GC TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION PRIOR TO PURCHASING GC TO SEE NOTES BELOW XGBM-FT-LED-LW-NW-UE-BLK UU3 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 Prefix FinishColor Temperature XGBM 1 - LED Greenbriar LED CW - Cool White (5000K) NW - Neutral White (4000K) Input Voltage UE - Universal Voltage (120-277) 347-480 BLK - Black BRZ - Bronze GPT - Graphite MSV - Metallic Silver PLP - Platinum Plus SVG - Satin Verde Green WHT - White Optional Color Decals 45 Light Gold 20 Charcoal Metallic 55 Black 94 Blue Metallic 59 Dark Green 51 Dark Red 21 Tomato Red 50 White 700 Aztec Silver Metallic Optional Sensor/OptionsOptional ControlsLight Source Distribution TYPICAL ORDER EXAMPLE: LUMINAIRE ORDERING INFORMATION XGBM 5 LED HO CW UE WHT PCM ACCESSORY ORDERING INFORMATION2 (Accessories are field installed) 482002 BLK7 162914BLK 123111CLR 169010CLR 144191CLR XGBM-HSS House Side Shield (Black only) RPP2 - Round Pole Plate BKS-BO-WM-*-CLR - Wall Mount Plate BKA-BO-RA-8-CLR - Radius Arm BKU-BO-S-19-CLR - Upsweep Bracket for round or square poles FK120 Single Fusing (120V) FK1208 FK277 Single Fusing (277V) FK2778 Description Order Number Order Number LUMINAIRE EPA CHART2 - XGBM Single D180° D90° T90° TN120° Q90° 8" Bracket 12" Bracket FOOTNOTES: 1- Use with 5" traditional drilling pattern. 2- For wireless controls information and accessories, see Controls section. 3- Requires a SiteManager and override switch. Not compatible with BLS or IMS option. 4- Not compatible with IMS or BLS option. 5- Not compatible with wireless controls system, DIM or IMS option. LW - Low Watt SS - Super Saver HO - High Output Drive Current DFK208,2408 DFK480 Double Fusing (480V) DFK4808 FK347 Single Fusing (347V) FK3478 PMOS120 - 120V Pole-Mount Occupancy Sensor 518030CLR9 PMOS208/240 - 208, 240V Pole-Mount Occupancy Sensor 534239CLR9 PMOS277 - 277V Pole-Mount Occupancy Sensor 518029CLR9 PMOS480 - 480V Pole-Mount Occupancy Sensor 534240CLR9 Description FT - Forward Throw FTA - Forward Throw Automotive 3 - Type III 5 - Type V 2.3 4.7 2.4 4.8 4.7 7.2 7.3 8.8 12" Bracket Required 6- Not compatible with wireless controls system, DIM or BLS option. 7- House Side Shields add to fixture EPA. Consult factory. 8- Fusing must be located in the hand hole of pole. 9- To be used with any of the PCM/GCM wireless controls systems in the fixture. Consult factory. 10-Photocell must be ordered separately. 7 pin standard. See Accessories. Note: House Side Shield adds to fixture EPA. Consult Factory. SensorWireless Control System2,3 (blank) - None PCM - Platinum Control System PCMH - Host/Satellite Platinum Control System GCM - Gold Control System GCMH - Host/Satellite Gold Control System DIM - 0-10 volt dimming (required for satellite fixtures) ALSC - AirLink Synapse Control System ALSCH - AirLink Synapse Control System - Host/Satelite IMS - Integral Motion Sensor6 PCI120 - 120V Button-Type Photocell PCI208 - 208V Button-Type Photocell PCI240 - 240V Button-Type Photocell PCI277 - 277V Button-Type Photocell PCI347 - 347V Button-Type Photocell Options 8BK - 8" Bracket (S and D180 only) TB - Terminal Block Stand-Alone Control (blank) - None DIM - 0-10 volt dimming4 (from external signal) BLS - Bi-level Switching5 (from external signal - required 120-277V controls system voltage) LED AREA LIGHTS - (XGBM) DIMENSIONS 24 sq. (610 mm) 9 (229 mm) 12 (305 mm) 3 15/16 (99 mm) 13 5/16 (339 mm) House Side Shield (482002BLK) 9 (229 mm) 5/8 (16 mm) 1-3/8 (35 mm) OPTIONAL IMS 2-1/4 (57 mm) 4-1/8 (105 mm) DFK208, 240 Double Fusing (208V, 240V) GC TO VERIFY AND SPECIFY IF NOT UE GC TO REFERENCE PLANS FOR COLOR DESIGNATION 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 BUG LISTING CW 26,754 300 89 B3-U0-G3 HO CW-HSS 17,316 288 60 B2-U0-G2 NW 22,240 289 77 B3-U0-G2 NW-HSS 13,941 288 48 B2-U0-G2 CW 14,082 140 100 B2-U0-G2 LW CW-HSS 9205 137 67 B1-U0-G2 NW 11,,451 137 84 B2-U0-G2 NW-HSS 7513 136 55 B1-U0-G2 CW 20181 187 108 B3-U0-G2 SS CW-HSS 13,034 187 70 B2-U0-G2 NW 16,394 189 87 B3-U0-G2 NW-HSS 10,384 189 55 B2-U0-G2 XGBM - Type 3 HO CW 25,464 300 85 B4-U0-G2 NW 20,549 288 71 B4-U0-G2 LW CW 13,842 140 99 B3-U0-G2 NW 11,291 136 83 B3-U0-G2 SS CW 18,044 186 97 B4-U0-G2 NW 15,173 189 80 B4-U0-G2 XGBM - Type 5 CW 31,808 301 106 B4-U0-G4 HO CW-HSS 20,838 288 72 B3-U0-G3 NW 25,407 289 88 B3-U0-G3 NW-HSS 16,855 289 58 B3-U0-G3 CW 16,560 140 118 B3-U0-G2 LW CW-HSS 11,440 137 84 B2-U0-G2 NW 13,473 136 99 B3-U0-G2 NW-HSS 9277 136 68 B2-U0-G2 CW 23,033 187 123 B3-U0-G3 SS CW-HSS 15,213 187 81 B3-U0-G2 NW 18,752 189 99 B3-U0-G3 NW-HSS 12,516 189 66 B2-U0-G3 , XGBM - Type FTA CW 29,070 301 97 B2-U0-G4 HO CW-HSS 20,964 288 73 B1-U0-G4 NW 23,512 289 81 B2-U0-G4 NW-HSS 17,191 289 60 B1-U0-G3 CW 15,019 141 107 B1-U0-G3 LW CW-HSS 11,519 137 84 B1-U0-G3 NW 12,217 136 90 B1-U0-G3 NW-HSS 9365 136 69 B1-U0-G3 CW 20,700 187 111 B2-U0-G3 SS CW-HSS 15,273 187 82 B1-U0-G3 NW 17,230 189 91 B1-U0-G3 NW-HSS 12,597 189 67 B1-U0-G3 XGBM - Type FT Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating * Color Temperature: NW-4000K, CW-5000K LED AREA LIGHTS - (XGBM) 2020-161485 12/15/20 10/12/17LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsi-industries.com • (513) 372-3200 • ©LSI Industries Inc. All Rights Reserved. enabled by Synapse® Wireless Lighting Controller The AirLink integrated controller is a California Title 24 compliant lighting controller that provides real-time light monitoring and control with utility-grade power monitoring. It includes a 24V sensor input and power supply to connect up to two (2) sensors into the outdoor AirLink wireless lighting system. The wireless integrated controller and twist lock controller are compatible with this fixture. Features • 2% Utility Grade Power Monitoring • Up to 80% Savings through smart dimming • True On/Off functionality via switched relay • Seamlessly integrates into the outdoor AirLink wireless lighting control solution & Self-healing Mesh Networking • Relay closes on power loss • Supports a wide range of LED drivers and fixtures • Class 1 / Class 2 0-10V Dimming Control • Direct Connect up to two (2) to 24V Occupancy Sensors and Photocells (consult sales for compatible list) • Secure, over-the-air upgrades to support future enhancements • Excellent RF Range — 1,000ft LoS between controllers • Available in a metal cased version with quick connect terminal blocks • Lights default to on for safety Specifications Regulatory Approvals • FCC, IC, CE certified • cULus Listed • California Title 24 compliant Power and Performance • Operating environmental: -40°F to 131°F (-40°C to 55°C) • Input power: 100–277 VAC +/- 10% (Max 305V)47/64 Hz • Switched output: Default ON; Zero Cross Switching • Load rating: 5A @ 100V to 277V (+/- 10%) • Dimming: 0–10V control; Output: Class 1/2 - 20mA Source Max / 50mA Sink Max • Power monitoring: Utility grade - 2% accuracy • Sensors inputs: 0–10V (photocell sensors), 0–24V (all other sensors); Sensor power supply: 24VDC @ 50mA Other • Dimensions: 8.2” L x 2.3” W x 1.3” H (209mm L x 59mm W x 33mm H) without antennas • Radio: SNAP 2.4 GHz; 802.15.4; +20 dBm Transmit Power; -105 dBm Receive Sensitivity • Warranty: 5 years Sales controls.sales@lsi-industries.com Support controls.support@lsi-industries.com 1 (800) 436-7800 (support, option 8) More information For more information on AirLink, visit our website at www.lsi-airlink.com/airlink Contact LSI Controls 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 DOE LIGHTING FACTS Department of Energy has verified representative product test data and results in accordance with its Lighting Facts Program. Visit www.lightingfacts.com for specific catalog strings. SMARTTEC™ THERMAL CONTROL - LSI drivers feature integral sensor which reduces drive current when ambient temperatures exceed rated temperature. OCCUPANCY SENSING (IMS) – Optional integral passive infrared motion sensor activates switching of luminaire light levels. High level light is activated and increased to full bright in 1-2 seconds upon detection of motion. Low light level (30% maximum drive current) is activated when target zone is absent of motion activity for ~2 minutes and ramps down (10-15 seconds) to low level to allow eyes time to adjust. Sensor is located on the front of optical assembly and rotates with the optic. Sensor optic has a detection cone of approximately 45°. Examples of detection – occurs 30' out from a 30' mounting height pole; occurs 20' out from a 20' mounting height pole. ENERGY SAVING CONTROL OPTIONS – DIM – 0-10 volt dimming enabled with controls by others. BLS – Bi-level switching responds to external line voltage signal from separate 120-277V controller or sensor (by others), with low light level decreased to 30% maximum drive current. LEDS - Select high-brightness LEDs in Cool White (5000K) or Neutral White (4000K) color temperature, 70 CRI. DISTRIBUTION/PERFORMANCE - Types 3, 5, FT and FTA available - field rotatable reflectors. HOUSING - Square, die-formed aluminum. Fully enclosed weather-tight housing contains factory prewired drivers and field connections. TOP-ACCESS COVER - Gasketed, tethered top-access cover provides ease of installation and allows for easy driver access. Four captive stainless-steel fasteners secure the top- access cover to the housing. OPTICAL UNIT - Clear tempered optical grade flat glass lens sealed to aluminum housing creates an IP67 rated, sealed optical unit (includes pressure stabilizing breather). Optical unit can be easily field rotated in 90o increments. Directional arrow on optics allows alignment without the unit being energized. MOUNTING - 2-1/2” x 5-3/8” x 12” extruded aluminum arm mounting bracket shipped standard. Use with 5” traditional drilling pattern. Round Pole Plate (RPP2) required for mounting to 3”– 5” round poles. (See Accessory Ordering Information chart.) ELECTRICAL - Two-stage surge protection (including separate surge protection built into electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal voltage power supply 120-277VAC (UE - 50/60Hz input), and 347-480VAC. DRIVERS - Available in Low Watt (LW), Super Saver (SS) and High Output (HO) drive currents (Drive currents are factory programmed). Components are fully encased in potting material for moisture resistance. Driver complies with FCC 47 CFR part 15 RFI/EMI standard. OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F). FINISH - Fixtures are finished with LSI's DuraGrip ® polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling. DECAL STRIPING - LSI offers optional color-coordinated decals in 9 standard colors to accent the fixture. Decals are guaranteed for five years against peeling, cracking, or fading. WARRANTY - LSI LED fixtures carry a limited 5-year warranty. PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed photometric data. SHIPPING WEIGHT (IN CARTON) - Fixture - 44.5 lbs (20 kg) Arm - 5 lbs. (2kg) arm LISTING - UL listed to U.S. and Canadian safety standards. Suitable for wet locations. For a list of the specific products in this series that are DLC listed, please consult the LED Lighting section of our website or the Design Lights website at www.designlights.org. LED AREA LIGHTS - (XGBM) US patent D574994 & 7,828,456 and MX patent 29631 and US & Int'l. patents pending Type 3 Type 5 Type FT Type FTA LIGHT OUTPUT - XGBM Lumens (Nominal) Watts (Nominal) LW 14080 13840 15020 16560 140 SS 20180 18040 20700 23030 187 HO 26750 25460 29070 31810 300 LW 11450 11290 12220 13470 136 SS 16390 15170 17230 18750 188 HO 22240 20550 23510 25410 288 Co o l W h i t e Ne u t r a l W h i t e LED Chips are frequently updated therefore values may increase. Shown with optional decal striping This product, or selected versions of this product, meet the standards listed below. Please consult factory for your specific requirements. wet location ARRA Funding Compliant IP67 Fixtures comply with ANSI C136.31-2010 American National Standard for Roadway Lighting Equipment - Luminaire Vibration 3G requirements. GC TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION PRIOR TO PURCHASING GC TO SEE NOTES BELOW XGBM-FT-LED-SS-NW-UE-BRZ UU4 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 Prefix FinishColor Temperature XGBM 1 - LED Greenbriar LED CW - Cool White (5000K) NW - Neutral White (4000K) Input Voltage UE - Universal Voltage (120-277) 347-480 BLK - Black BRZ - Bronze GPT - Graphite MSV - Metallic Silver PLP - Platinum Plus SVG - Satin Verde Green WHT - White Optional Color Decals 45 Light Gold 20 Charcoal Metallic 55 Black 94 Blue Metallic 59 Dark Green 51 Dark Red 21 Tomato Red 50 White 700 Aztec Silver Metallic Optional Sensor/OptionsOptional ControlsLight Source Distribution TYPICAL ORDER EXAMPLE: LUMINAIRE ORDERING INFORMATION XGBM 5 LED HO CW UE WHT PCM ACCESSORY ORDERING INFORMATION2 (Accessories are field installed) 482002 BLK7 162914BLK 123111CLR 169010CLR 144191CLR XGBM-HSS House Side Shield (Black only) RPP2 - Round Pole Plate BKS-BO-WM-*-CLR - Wall Mount Plate BKA-BO-RA-8-CLR - Radius Arm BKU-BO-S-19-CLR - Upsweep Bracket for round or square poles FK120 Single Fusing (120V) FK1208 FK277 Single Fusing (277V) FK2778 Description Order Number Order Number LUMINAIRE EPA CHART2 - XGBM Single D180° D90° T90° TN120° Q90° 8" Bracket 12" Bracket FOOTNOTES: 1- Use with 5" traditional drilling pattern. 2- For wireless controls information and accessories, see Controls section. 3- Requires a SiteManager and override switch. Not compatible with BLS or IMS option. 4- Not compatible with IMS or BLS option. 5- Not compatible with wireless controls system, DIM or IMS option. LW - Low Watt SS - Super Saver HO - High Output Drive Current DFK208,2408 DFK480 Double Fusing (480V) DFK4808 FK347 Single Fusing (347V) FK3478 PMOS120 - 120V Pole-Mount Occupancy Sensor 518030CLR9 PMOS208/240 - 208, 240V Pole-Mount Occupancy Sensor 534239CLR9 PMOS277 - 277V Pole-Mount Occupancy Sensor 518029CLR9 PMOS480 - 480V Pole-Mount Occupancy Sensor 534240CLR9 Description FT - Forward Throw FTA - Forward Throw Automotive 3 - Type III 5 - Type V 2.3 4.7 2.4 4.8 4.7 7.2 7.3 8.8 12" Bracket Required 6- Not compatible with wireless controls system, DIM or BLS option. 7- House Side Shields add to fixture EPA. Consult factory. 8- Fusing must be located in the hand hole of pole. 9- To be used with any of the PCM/GCM wireless controls systems in the fixture. Consult factory. 10-Photocell must be ordered separately. 7 pin standard. See Accessories. Note: House Side Shield adds to fixture EPA. Consult Factory. SensorWireless Control System2,3 (blank) - None PCM - Platinum Control System PCMH - Host/Satellite Platinum Control System GCM - Gold Control System GCMH - Host/Satellite Gold Control System DIM - 0-10 volt dimming (required for satellite fixtures) ALSC - AirLink Synapse Control System ALSCH - AirLink Synapse Control System - Host/Satelite IMS - Integral Motion Sensor6 PCI120 - 120V Button-Type Photocell PCI208 - 208V Button-Type Photocell PCI240 - 240V Button-Type Photocell PCI277 - 277V Button-Type Photocell PCI347 - 347V Button-Type Photocell Options 8BK - 8" Bracket (S and D180 only) TB - Terminal Block Stand-Alone Control (blank) - None DIM - 0-10 volt dimming4 (from external signal) BLS - Bi-level Switching5 (from external signal - required 120-277V controls system voltage) LED AREA LIGHTS - (XGBM) DIMENSIONS 24 sq. (610 mm) 9 (229 mm) 12 (305 mm) 3 15/16 (99 mm) 13 5/16 (339 mm) House Side Shield (482002BLK) 9 (229 mm) 5/8 (16 mm) 1-3/8 (35 mm) OPTIONAL IMS 2-1/4 (57 mm) 4-1/8 (105 mm) DFK208, 240 Double Fusing (208V, 240V) GC TO VERIFY AND SPECIFY IF NOT UE GC TO REFERENCE PLANS FOR COLOR DESIGNATION 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 BUG LISTING CW 26,754 300 89 B3-U0-G3 HO CW-HSS 17,316 288 60 B2-U0-G2 NW 22,240 289 77 B3-U0-G2 NW-HSS 13,941 288 48 B2-U0-G2 CW 14,082 140 100 B2-U0-G2 LW CW-HSS 9205 137 67 B1-U0-G2 NW 11,,451 137 84 B2-U0-G2 NW-HSS 7513 136 55 B1-U0-G2 CW 20181 187 108 B3-U0-G2 SS CW-HSS 13,034 187 70 B2-U0-G2 NW 16,394 189 87 B3-U0-G2 NW-HSS 10,384 189 55 B2-U0-G2 XGBM - Type 3 HO CW 25,464 300 85 B4-U0-G2 NW 20,549 288 71 B4-U0-G2 LW CW 13,842 140 99 B3-U0-G2 NW 11,291 136 83 B3-U0-G2 SS CW 18,044 186 97 B4-U0-G2 NW 15,173 189 80 B4-U0-G2 XGBM - Type 5 CW 31,808 301 106 B4-U0-G4 HO CW-HSS 20,838 288 72 B3-U0-G3 NW 25,407 289 88 B3-U0-G3 NW-HSS 16,855 289 58 B3-U0-G3 CW 16,560 140 118 B3-U0-G2 LW CW-HSS 11,440 137 84 B2-U0-G2 NW 13,473 136 99 B3-U0-G2 NW-HSS 9277 136 68 B2-U0-G2 CW 23,033 187 123 B3-U0-G3 SS CW-HSS 15,213 187 81 B3-U0-G2 NW 18,752 189 99 B3-U0-G3 NW-HSS 12,516 189 66 B2-U0-G3 , XGBM - Type FTA CW 29,070 301 97 B2-U0-G4 HO CW-HSS 20,964 288 73 B1-U0-G4 NW 23,512 289 81 B2-U0-G4 NW-HSS 17,191 289 60 B1-U0-G3 CW 15,019 141 107 B1-U0-G3 LW CW-HSS 11,519 137 84 B1-U0-G3 NW 12,217 136 90 B1-U0-G3 NW-HSS 9365 136 69 B1-U0-G3 CW 20,700 187 111 B2-U0-G3 SS CW-HSS 15,273 187 82 B1-U0-G3 NW 17,230 189 91 B1-U0-G3 NW-HSS 12,597 189 67 B1-U0-G3 XGBM - Type FT Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating * Color Temperature: NW-4000K, CW-5000K LED AREA LIGHTS - (XGBM) 2020-161485 12/15/20 10/12/17LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsi-industries.com • (513) 372-3200 • ©LSI Industries Inc. All Rights Reserved. enabled by Synapse® Wireless Lighting Controller The AirLink integrated controller is a California Title 24 compliant lighting controller that provides real-time light monitoring and control with utility-grade power monitoring. It includes a 24V sensor input and power supply to connect up to two (2) sensors into the outdoor AirLink wireless lighting system. The wireless integrated controller and twist lock controller are compatible with this fixture. Features • 2% Utility Grade Power Monitoring • Up to 80% Savings through smart dimming • True On/Off functionality via switched relay • Seamlessly integrates into the outdoor AirLink wireless lighting control solution & Self-healing Mesh Networking • Relay closes on power loss • Supports a wide range of LED drivers and fixtures • Class 1 / Class 2 0-10V Dimming Control • Direct Connect up to two (2) to 24V Occupancy Sensors and Photocells (consult sales for compatible list) • Secure, over-the-air upgrades to support future enhancements • Excellent RF Range — 1,000ft LoS between controllers • Available in a metal cased version with quick connect terminal blocks • Lights default to on for safety Specifications Regulatory Approvals • FCC, IC, CE certified • cULus Listed • California Title 24 compliant Power and Performance • Operating environmental: -40°F to 131°F (-40°C to 55°C) • Input power: 100–277 VAC +/- 10% (Max 305V)47/64 Hz • Switched output: Default ON; Zero Cross Switching • Load rating: 5A @ 100V to 277V (+/- 10%) • Dimming: 0–10V control; Output: Class 1/2 - 20mA Source Max / 50mA Sink Max • Power monitoring: Utility grade - 2% accuracy • Sensors inputs: 0–10V (photocell sensors), 0–24V (all other sensors); Sensor power supply: 24VDC @ 50mA Other • Dimensions: 8.2” L x 2.3” W x 1.3” H (209mm L x 59mm W x 33mm H) without antennas • Radio: SNAP 2.4 GHz; 802.15.4; +20 dBm Transmit Power; -105 dBm Receive Sensitivity • Warranty: 5 years Sales controls.sales@lsi-industries.com Support controls.support@lsi-industries.com 1 (800) 436-7800 (support, option 8) More information For more information on AirLink, visit our website at www.lsi-airlink.com/airlink Contact LSI Controls 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 DOE LIGHTING FACTS Department of Energy has verified representative product test data and results in accordance with its Lighting Facts Program. Visit www.lightingfacts.com for specific catalog strings. SMARTTEC™ THERMAL CONTROL - LSI drivers feature integral sensor which reduces drive current when ambient temperatures exceed rated temperature. OCCUPANCY SENSING (IMS) – Optional integral passive infrared motion sensor activates switching of luminaire light levels. High level light is activated and increased to full bright in 1-2 seconds upon detection of motion. Low light level (30% maximum drive current) is activated when target zone is absent of motion activity for ~2 minutes and ramps down (10-15 seconds) to low level to allow eyes time to adjust. Sensor is located on the front of optical assembly and rotates with the optic. Sensor optic has a detection cone of approximately 45°. Examples of detection – occurs 30' out from a 30' mounting height pole; occurs 20' out from a 20' mounting height pole. ENERGY SAVING CONTROL OPTIONS – DIM – 0-10 volt dimming enabled with controls by others. BLS – Bi-level switching responds to external line voltage signal from separate 120-277V controller or sensor (by others), with low light level decreased to 30% maximum drive current. LEDS - Select high-brightness LEDs in Cool White (5000K) or Neutral White (4000K) color temperature, 70 CRI. DISTRIBUTION/PERFORMANCE - Types 3, 5, FT and FTA available - field rotatable reflectors. HOUSING - Square, die-formed aluminum. Fully enclosed weather-tight housing contains factory prewired drivers and field connections. TOP-ACCESS COVER - Gasketed, tethered top-access cover provides ease of installation and allows for easy driver access. Four captive stainless-steel fasteners secure the top- access cover to the housing. OPTICAL UNIT - Clear tempered optical grade flat glass lens sealed to aluminum housing creates an IP67 rated, sealed optical unit (includes pressure stabilizing breather). Optical unit can be easily field rotated in 90o increments. Directional arrow on optics allows alignment without the unit being energized. MOUNTING - 2-1/2” x 5-3/8” x 12” extruded aluminum arm mounting bracket shipped standard. Use with 5” traditional drilling pattern. Round Pole Plate (RPP2) required for mounting to 3”– 5” round poles. (See Accessory Ordering Information chart.) ELECTRICAL - Two-stage surge protection (including separate surge protection built into electronic driver) meets IEEE C62.41.2-2002, Location Category C. Available with universal voltage power supply 120-277VAC (UE - 50/60Hz input), and 347-480VAC. DRIVERS - Available in Low Watt (LW), Super Saver (SS) and High Output (HO) drive currents (Drive currents are factory programmed). Components are fully encased in potting material for moisture resistance. Driver complies with FCC 47 CFR part 15 RFI/EMI standard. OPERATING TEMPERATURE - -40°C to +50°C (-40°F to +122°F). FINISH - Fixtures are finished with LSI's DuraGrip ® polyester powder coat finishing process. The DuraGrip finish withstands extreme weather changes without cracking or peeling. DECAL STRIPING - LSI offers optional color-coordinated decals in 9 standard colors to accent the fixture. Decals are guaranteed for five years against peeling, cracking, or fading. WARRANTY - LSI LED fixtures carry a limited 5-year warranty. PHOTOMETRICS - Please visit our web site at www.lsi-industries.com for detailed photometric data. SHIPPING WEIGHT (IN CARTON) - Fixture - 44.5 lbs (20 kg) Arm - 5 lbs. (2kg) arm LISTING - UL listed to U.S. and Canadian safety standards. Suitable for wet locations. For a list of the specific products in this series that are DLC listed, please consult the LED Lighting section of our website or the Design Lights website at www.designlights.org. LED AREA LIGHTS - (XGBM) US patent D574994 & 7,828,456 and MX patent 29631 and US & Int'l. patents pending Type 3 Type 5 Type FT Type FTA LIGHT OUTPUT - XGBM Lumens (Nominal) Watts (Nominal) LW 14080 13840 15020 16560 140 SS 20180 18040 20700 23030 187 HO 26750 25460 29070 31810 300 LW 11450 11290 12220 13470 136 SS 16390 15170 17230 18750 188 HO 22240 20550 23510 25410 288 Co o l W h i t e Ne u t r a l W h i t e LED Chips are frequently updated therefore values may increase. Shown with optional decal striping This product, or selected versions of this product, meet the standards listed below. Please consult factory for your specific requirements. wet location ARRA Funding Compliant IP67 Fixtures comply with ANSI C136.31-2010 American National Standard for Roadway Lighting Equipment - Luminaire Vibration 3G requirements. GC TO VERIFY THAT FIXTURES CAN BE MOUNTED PER PLAN AND ALL NECESSARY HARDWARE IS SPECIFIED FOR INSTALLATION PRIOR TO PURCHASING GC TO SEE NOTES BELOW XGBM-FT-LED-HO-NW-UE-BLK UU5 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 Prefix FinishColor Temperature XGBM 1 - LED Greenbriar LED CW - Cool White (5000K) NW - Neutral White (4000K) Input Voltage UE - Universal Voltage (120-277) 347-480 BLK - Black BRZ - Bronze GPT - Graphite MSV - Metallic Silver PLP - Platinum Plus SVG - Satin Verde Green WHT - White Optional Color Decals 45 Light Gold 20 Charcoal Metallic 55 Black 94 Blue Metallic 59 Dark Green 51 Dark Red 21 Tomato Red 50 White 700 Aztec Silver Metallic Optional Sensor/OptionsOptional ControlsLight Source Distribution TYPICAL ORDER EXAMPLE: LUMINAIRE ORDERING INFORMATION XGBM 5 LED HO CW UE WHT PCM ACCESSORY ORDERING INFORMATION2 (Accessories are field installed) 482002 BLK7 162914BLK 123111CLR 169010CLR 144191CLR XGBM-HSS House Side Shield (Black only) RPP2 - Round Pole Plate BKS-BO-WM-*-CLR - Wall Mount Plate BKA-BO-RA-8-CLR - Radius Arm BKU-BO-S-19-CLR - Upsweep Bracket for round or square poles FK120 Single Fusing (120V) FK1208 FK277 Single Fusing (277V) FK2778 Description Order Number Order Number LUMINAIRE EPA CHART2 - XGBM Single D180° D90° T90° TN120° Q90° 8" Bracket 12" Bracket FOOTNOTES: 1- Use with 5" traditional drilling pattern. 2- For wireless controls information and accessories, see Controls section. 3- Requires a SiteManager and override switch. Not compatible with BLS or IMS option. 4- Not compatible with IMS or BLS option. 5- Not compatible with wireless controls system, DIM or IMS option. LW - Low Watt SS - Super Saver HO - High Output Drive Current DFK208,2408 DFK480 Double Fusing (480V) DFK4808 FK347 Single Fusing (347V) FK3478 PMOS120 - 120V Pole-Mount Occupancy Sensor 518030CLR9 PMOS208/240 - 208, 240V Pole-Mount Occupancy Sensor 534239CLR9 PMOS277 - 277V Pole-Mount Occupancy Sensor 518029CLR9 PMOS480 - 480V Pole-Mount Occupancy Sensor 534240CLR9 Description FT - Forward Throw FTA - Forward Throw Automotive 3 - Type III 5 - Type V 2.3 4.7 2.4 4.8 4.7 7.2 7.3 8.8 12" Bracket Required 6- Not compatible with wireless controls system, DIM or BLS option. 7- House Side Shields add to fixture EPA. Consult factory. 8- Fusing must be located in the hand hole of pole. 9- To be used with any of the PCM/GCM wireless controls systems in the fixture. Consult factory. 10-Photocell must be ordered separately. 7 pin standard. See Accessories. Note: House Side Shield adds to fixture EPA. Consult Factory. SensorWireless Control System2,3 (blank) - None PCM - Platinum Control System PCMH - Host/Satellite Platinum Control System GCM - Gold Control System GCMH - Host/Satellite Gold Control System DIM - 0-10 volt dimming (required for satellite fixtures) ALSC - AirLink Synapse Control System ALSCH - AirLink Synapse Control System - Host/Satelite IMS - Integral Motion Sensor6 PCI120 - 120V Button-Type Photocell PCI208 - 208V Button-Type Photocell PCI240 - 240V Button-Type Photocell PCI277 - 277V Button-Type Photocell PCI347 - 347V Button-Type Photocell Options 8BK - 8" Bracket (S and D180 only) TB - Terminal Block Stand-Alone Control (blank) - None DIM - 0-10 volt dimming4 (from external signal) BLS - Bi-level Switching5 (from external signal - required 120-277V controls system voltage) LED AREA LIGHTS - (XGBM) DIMENSIONS 24 sq. (610 mm) 9 (229 mm) 12 (305 mm) 3 15/16 (99 mm) 13 5/16 (339 mm) House Side Shield (482002BLK) 9 (229 mm) 5/8 (16 mm) 1-3/8 (35 mm) OPTIONAL IMS 2-1/4 (57 mm) 4-1/8 (105 mm) DFK208, 240 Double Fusing (208V, 240V) GC TO VERIFY AND SPECIFY IF NOT UE GC TO REFERENCE PLANS FOR COLOR DESIGNATION 2020-161485 12/15/20 © 2017 LSI INDUSTRIES INC. Project Name Fixture Type Catalog # 10/16/17 BUG LISTING CW 26,754 300 89 B3-U0-G3 HO CW-HSS 17,316 288 60 B2-U0-G2 NW 22,240 289 77 B3-U0-G2 NW-HSS 13,941 288 48 B2-U0-G2 CW 14,082 140 100 B2-U0-G2 LW CW-HSS 9205 137 67 B1-U0-G2 NW 11,,451 137 84 B2-U0-G2 NW-HSS 7513 136 55 B1-U0-G2 CW 20181 187 108 B3-U0-G2 SS CW-HSS 13,034 187 70 B2-U0-G2 NW 16,394 189 87 B3-U0-G2 NW-HSS 10,384 189 55 B2-U0-G2 XGBM - Type 3 HO CW 25,464 300 85 B4-U0-G2 NW 20,549 288 71 B4-U0-G2 LW CW 13,842 140 99 B3-U0-G2 NW 11,291 136 83 B3-U0-G2 SS CW 18,044 186 97 B4-U0-G2 NW 15,173 189 80 B4-U0-G2 XGBM - Type 5 CW 31,808 301 106 B4-U0-G4 HO CW-HSS 20,838 288 72 B3-U0-G3 NW 25,407 289 88 B3-U0-G3 NW-HSS 16,855 289 58 B3-U0-G3 CW 16,560 140 118 B3-U0-G2 LW CW-HSS 11,440 137 84 B2-U0-G2 NW 13,473 136 99 B3-U0-G2 NW-HSS 9277 136 68 B2-U0-G2 CW 23,033 187 123 B3-U0-G3 SS CW-HSS 15,213 187 81 B3-U0-G2 NW 18,752 189 99 B3-U0-G3 NW-HSS 12,516 189 66 B2-U0-G3 , XGBM - Type FTA CW 29,070 301 97 B2-U0-G4 HO CW-HSS 20,964 288 73 B1-U0-G4 NW 23,512 289 81 B2-U0-G4 NW-HSS 17,191 289 60 B1-U0-G3 CW 15,019 141 107 B1-U0-G3 LW CW-HSS 11,519 137 84 B1-U0-G3 NW 12,217 136 90 B1-U0-G3 NW-HSS 9365 136 69 B1-U0-G3 CW 20,700 187 111 B2-U0-G3 SS CW-HSS 15,273 187 82 B1-U0-G3 NW 17,230 189 91 B1-U0-G3 NW-HSS 12,597 189 67 B1-U0-G3 XGBM - Type FT Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating Drive Current Color Temp.* Lumens Watts LER BUG Rating * Color Temperature: NW-4000K, CW-5000K LED AREA LIGHTS - (XGBM) 2020-161485 12/15/20 10/12/17LSI Industries Inc. 10000 Alliance Rd. Cincinnati, OH 45242 • www.lsi-industries.com • (513) 372-3200 • ©LSI Industries Inc. All Rights Reserved. enabled by Synapse® Wireless Lighting Controller The AirLink integrated controller is a California Title 24 compliant lighting controller that provides real-time light monitoring and control with utility-grade power monitoring. It includes a 24V sensor input and power supply to connect up to two (2) sensors into the outdoor AirLink wireless lighting system. The wireless integrated controller and twist lock controller are compatible with this fixture. Features • 2% Utility Grade Power Monitoring • Up to 80% Savings through smart dimming • True On/Off functionality via switched relay • Seamlessly integrates into the outdoor AirLink wireless lighting control solution & Self-healing Mesh Networking • Relay closes on power loss • Supports a wide range of LED drivers and fixtures • Class 1 / Class 2 0-10V Dimming Control • Direct Connect up to two (2) to 24V Occupancy Sensors and Photocells (consult sales for compatible list) • Secure, over-the-air upgrades to support future enhancements • Excellent RF Range — 1,000ft LoS between controllers • Available in a metal cased version with quick connect terminal blocks • Lights default to on for safety Specifications Regulatory Approvals • FCC, IC, CE certified • cULus Listed • California Title 24 compliant Power and Performance • Operating environmental: -40°F to 131°F (-40°C to 55°C) • Input power: 100–277 VAC +/- 10% (Max 305V)47/64 Hz • Switched output: Default ON; Zero Cross Switching • Load rating: 5A @ 100V to 277V (+/- 10%) • Dimming: 0–10V control; Output: Class 1/2 - 20mA Source Max / 50mA Sink Max • Power monitoring: Utility grade - 2% accuracy • Sensors inputs: 0–10V (photocell sensors), 0–24V (all other sensors); Sensor power supply: 24VDC @ 50mA Other • Dimensions: 8.2” L x 2.3” W x 1.3” H (209mm L x 59mm W x 33mm H) without antennas • Radio: SNAP 2.4 GHz; 802.15.4; +20 dBm Transmit Power; -105 dBm Receive Sensitivity • Warranty: 5 years Sales controls.sales@lsi-industries.com Support controls.support@lsi-industries.com 1 (800) 436-7800 (support, option 8) More information For more information on AirLink, visit our website at www.lsi-airlink.com/airlink Contact LSI Controls 2020-161485 12/15/20 30 ' - " 6 0 ' - " 0 255 4095 16041 KK/MF 6/12/2020 "0 B of A Lighting ( CA6-204 ) - SANTA ANA , CALIFORNIA 95#5 MA X P O L E H E I G H T 2,500 , MAX WATER/CEMENT RATIO = 0.5 ANCHOR BOLTS SEE A/- 0 BASE PLATE SEE A/- ASTM A36 12"x12"x1" BASE PL W/(4) 3/4" DIA. MIN X 24" MIN EMBED GR 36 MIN ANCHOR BOLTS 12.75" CIRCULAR BOLT THE ASSUMED ALLOWABLE BEARING PRESSURE IS 1500 PSF AND ALLOWABLE LATERAL BEARING PRESSURE IS 100 PSF PER FOOT PER CBC 2019 TABLE 1806.2 WITH SITE CLASS D. THIS DETAIL IS NOT APPLICABLE AT MUD, ORGANIC SILT, ORGANIC CLAYS, PEAT OR UNPREPARED FILL UNLESS DEEMED ACCEPTABLE BY THE LOCAL CODE OFFICIAL. 1"MIN, TYP 1 " MI N , T Y P LIGHT POLE PER MFR HSS 5"x5"x0.18" MIN ASTM A500 GR 46 OR HSS 5"DIA. x0.18" MIN ASTM A500 GR 46 LIGHT PER MFR, WT = 55 LBS MAX, PROJECTED WIND AREA =2.00 SQ FT MAX THE FOOTING IS DESIGNED PER CBC 2019 SECTION 1807 AND ASCE 7-16 1" MIN NON-SHRINK, NON-METALLIC GROUT 2,500 PSI AT 28 DAYS Date Signed: 06/12/2020 2020-161485 12/15/20 STRUCTURAL CALCULATIONS B of A CA6-204 3730 S Bristol St Santa Ana, CA prepared for Rogers Electric 1506 West Whispering Wind Dr. Suite 125 Phoenix, AZ, 85085 prepared by John A. Martin & Associates, Inc. 950 South Grand Avenue, Suite 400 Los Angeles, California 90015 213.483.6490 JAMA Project No. 16041 Date 6/12/20 950 SOUTH GRAND AVENUE, 4TH FLOOR | LOS ANGELES, CA 90015 | 213.483.6490 T | 213.483.3084 F | WWW.JOHNMARTIN.COM Date Signed: 06/12/2020 2020-161485 12/15/20 Hazards by Location Search Information Address: 3730 S Bristol St, Santa Ana, CA 92704, USA Coordinates: 33.697256, -117.8868186 Elevation: 37 ft Timestamp: 2020-06-12T23:12:38.797Z Hazard Type: Seismic Reference Document: ASCE7-16 Risk Category: II Site Class: D-default Basic Parameters Name Value Description SS 1.287 MCE R ground motion (period=0.2s) S1 0.461 MCE R ground motion (period=1.0s) SMS 1.544 Site-modified spectral acceleration value SM1 * null Site-modified spectral acceleration value SDS 1.029 Numeric seismic design value at 0.2s SA SD1 * null Numeric seismic design value at 1.0s SA * See Section 11.4.8 Additional Information Name Value Description SDC * null Seismic design category Fa 1.2 Site amplification factor at 0.2s Fv * null Site amplification factor at 1.0s CRS 0.924 Coefficient of risk (0.2s) CR1 0.925 Coefficient of risk (1.0s) PGA 0.55 MCE G peak ground acceleration 37 ft Map data ©2020 Google, INEGI Report a map error Page 1 of 2ATC Hazards by Location 6/12/2020https://hazards.atcouncil.org/ 2020-161485 12/15/20 S1D 0.685 Factored deterministic acceleration value (1.0s) PGAd 0.816 Factored deterministic acceleration value (PGA) * See Section 11.4.8 The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are provided by the U.S. Geological Survey Seismic Design Web Services. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. Page 2 of 2ATC Hazards by Location 6/12/2020https://hazards.atcouncil.org/ 2020-161485 12/15/20 Hazards by Location Search Information Address: 3730 S Bristol St, Santa Ana, CA 92704, USA Coordinates: 33.697256, -117.8868186 Elevation: 37 ft Timestamp: 2020-06-12T23:11:48.215Z Hazard Type: Wind ASCE 7-16 MRI 10-Year 66 mph MRI 25-Year 71 mph MRI 50-Year 77 mph MRI 100-Year 81 mph Risk Category I 89 mph Risk Category II 95 mph Risk Category III 102 mph Risk Category IV 106 mph ASCE 7-10 MRI 10-Year 72 mph MRI 25-Year 79 mph MRI 50-Year 85 mph MRI 100-Year 91 mph Risk Category I 100 mph Risk Category II 110 mph Risk Category III-IV 115 mph ASCE 7-05 ASCE 7-05 Wind Speed 85 mph The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area – in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. 37 ft Map data ©2020 Google, INEGI Report a map error Page 1 of 2ATC Hazards by Location 6/12/2020https://hazards.atcouncil.org/ 2020-161485 12/15/20 1 of 2 JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS Client: Sheet Project: Job No 16041 Date 6/12/2020 Engineer KK/MF Wind Analysis (ASCE 7-16 Chapter 29) F = qzGCfA qz = 0.00256KzKztKdKeV2 Kzt= 1 Fig. 26.8-1 (Not applicable at high elevation, escarpment, ridge, or hill/mountain) Kd = 0.9 Table 26.6-1 Ke 1 Table 26.9-1 Kz Table 26.10 V = 95 mph Exp C H = 30 ft (max) G Section 26.11 Cf Figure 29.4-1 Pole centroid (ft) Kz qz (psf) Cf G Length (ft) Width (in) Area (ft2) 0-3 ft conc. Base 1.5 0.85 17.7 2 0.85 3.0 24 6.00 3-15 ft 9 0.85 17.7 2 0.85 12.0 5 5.00 15-20 ft 17.5 0.9 18.7 2 0.85 5.0 5 2.08 20-25 ft 22.5 0.94 19.5 2 0.85 5.0 5 2.08 25-30 ft 27.5 0.964 20.0 2 0.85 5.0 5 2.08 (G Type) OSQ-A-NM 30 0.98 20.4 2 0.85 2.00 (ASD) Forces at finished grade Frost Depth = 0 ft (for areas not adjacent heated spaces) Pole F (lbs) Mo (ft-lb) 0-3 ft Concrete Base 108.2 162 3-15 ft 90.1 811 15-20 ft 39.8 696 20-25 ft 41.5 935 25-28 ft 42.6 1171 (G Type) OSQ-A-NM 41.6 1247 Sum = 364 5022 Heq = Mo/F = 13.8 ft Forces at pole base Pole centroid (ft) F (lbs) Mo (ft-lb) 3-15 ft 6 150.2 901 15-20 ft 14.5 66.3 961 20-25 ft 19.5 69.2 1350 25-28 ft 24.5 71.0 1739 OSQ-A-NM Series 27 69.3 1871 Sum = 426 6822 ASD Forces at pole Base = 255 4095 Rogers Electric CBC 2019 CA6-204 SANTA ANA, CALIFORNIA 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\Santa Ana - CA6-204\1 cover page.xlsm p-1 2020-161485 12/15/20 2 of 2 JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS Client: Sheet Project: Job No 16041 Date 6/12/2020 Engineer KK/MF Rogers Electric CBC 2019 CA6-204 SANTA ANA, CALIFORNIA Seismic (ASCE 7-16 Chapter 13) Fp = 0.4apSdsIpWp(1+2z/h)/Rp ASCE Table 13.6-1: Light Fixture Fp min = 0.3SdsIpWp ap = 1 Sds = 1.029 Rp = 1.5 Ip = 1 z/h = 0 Fp = 0.4apSdsIpWp(1+2z/h)/Rp = 0.27 /Wp Fp min = 0.3SdsIpWp = 0.31 /Wp Control centroid (ft) Wp (lbs) Fp (lbs) Mo (ft-lb) Pole 15 183 56 847 (G Type) OSQ-A-NM 30 55 17 509 Sum = 238 73 1357 WIND GOVERNS Foundation (CBC 2019 section 1807.3.2.1 Nonconstrained) d^ = A/2(1+(1+4.36Heq/A)1/2) Bearing Pressure = WT/Ftg area S1 = 1/3*(L)*(d^) WT = 238 lbs 2 ft Ftg Area = 3.14 ft2 5.04 ft (TRIAL) Bearing Pressure = 76 psf 13.8 ft Bearing Pressure Allow = 1500 psf 364 lbs 200 lbs/sq/ft/ft S1 = 336 A = 1.27 d^ = 5.04 ft (ACTUAL) d^actual - d^trial = 0.00 OK A = 2.34P/(S1b) b = d^ = Heq = Distance from ground surface to point of application 'P" P = Applied lateral force S1 = (L) = Allowable lateral soil-bearing pressure USE Min Footing Depth = 6.00 ft ftg depth (d^) = ftg diameter (b) = Diameter of round post or footing or diagonal dimension of square post or footing Depth of embedment in earth but not over 12 feet for purpose of computing lateral pressure Allowable lateral soil-bearing pressure based on a depth of one-third the depth of embedment Heq = Pasd (P) = Lateral Bearing# (L) # Lateral Bearing may equal two times the value of Table 1806.2 per section 1806.3.4 CBC 2019 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\Santa Ana - CA6-204\1 cover page.xlsm p-2 2020-161485 12/15/20 1 of 1 JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS Client: Sheet Project: Job No 16041 Date 6/12/2020 Engineer KK/MF Base Plate Analysis N = 12 in Minimum 12" Square Plate x 1" Thick B = 12 in tp = 1 in Fy = 36 ksi f = N/2 = 6.0 in f'c = 2500 psi fp,max = 1381 psi qmax = 16575 lbs/in Mr = 6822 lb-ft Pr = 238 lbs e = Mr/Pr = 344 in > ecrit = N/2 - Pr/2/qmax 6.0 in Design of Column Base Plates with Large Moment (Design Guide 1) Y = (f+N/2) - ((f+N/2)2- 2Pr(e+f)/qmax)1/2 = 0.4 in Tu = qY-Pu = 6829 lbs Y < m = 3.63 in Bearing Interface: m = (N-0.95d)/2 = 3.63 in tp,req = 2.11(fpY(m-Y/2)/Fy)1/2 = 0.50 in Tension Interface: x = N/2-d/2-1 = 2.50 in tp,req = 2.11(Tux/B/Fy)1/2 = 0.42 in tp = 1 in > tp,req = 0.50 in OK DCR = 0.50 Anchor Bolts Minimum (4) 3/4" Dia. x 24" Anchor Bolts Wind Forces on Anchors= Seismic Forces on Anchors= Vu = 426 lbs ΩVu = 78 lbs Mu = 6822 lb-ft ΩMu = 1052 lb-ft *Wind governs anchorage analaysis. See attached Hilti Profis Report for anchorage analysis. Forces per bolt = d = 9.52 in Tu,bolt = Mu/d = 4302 lbs φTn = 5866 lbs DCR = 0.73 Vu,bolt = Vu/4 = 107 lbs φVn = 1337 lbs DCR = 0.08 DCR = (Tu/Tn)5/3 + (Vu/Vn)5/3 = 0.61 ok Rogers Electric CBC 2019 CA6-204 SANTA ANA, CALIFORNIA 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\Santa Ana - CA6-204\1 cover page.xlsm p-1 2020-161485 12/15/20 1 of 1 JOHN A. MARTIN and ASSOCIATES, INC. □ STRUCTURAL ENGINEERS Client: Sheet Project: Job No 16041 Date 6/12/2020 Engineer KK/MF Light pole analysis Square pole d = 5 in bf = 5 in t = 0.18 in Fy = 46 ksi d1 = d - 2t = 4.64 in b1 = b - 2t = 4.64 in Zx = bd2/4 - (b-2t)(d-2t)2/4 = 6.28 in3 Round Pole d = 5 in t = 0.18 in Fy = 46 ksi d1 = d - 2t = 4.64 in Zx = d3/6-d1 3/6 = 4.18 in3 Light Pole Bending Capacity Zx,min = 4.18 in3 Fy = 46 ksi φMn = 0.9FyZx = 14434 lb-ft > Mu = 6822 ok DCR = 0.47 Rogers Electric CBC 2019 CA6-204 SANTA ANA, CALIFORNIA 950 SOUTH GRAND AVENUE, 4TH FLOOR LOS ANGELES, CA 90015 213.483.6490 G:\Job16000\J16041 Light Pole Foundation\Engineering\Calcs\Santa Ana - CA6-204\1 cover page.xlsm p-1 2020-161485 12/15/20 P (kip) Mx (k-ft) 1200 -200 250-250 fs=0.5fy fs=0 fs=0.5fy fs=0 (Pmax)(Pmax) (Pmin)(Pmin) fs=0.5fy fs=0 fs=0.5fy fs=0 1 2020-161485 12/15/20 www.hilti.us Profis Anchor 2.7.5 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Company: Specifier: Address: Phone I Fax: E-Mail: | Page: Project: Sub-Project I Pos. No.: Date: 1 6/27/2019 Specifier's comments: 1 Input data Anchor type and diameter: Hex Head ASTM F 1554 GR. 36 3/4 Effective embedment depth: hef = 24.000 in. Material: ASTM F 1554 Proof: Design method ACI 318-14 / CIP Stand-off installation: eb = 0.000 in. (no stand-off); t = 1.000 in. Anchor plate: lx x ly x t = 12.000 in. x 12.000 in. x 1.000 in.; (Recommended plate thickness: not calculated Profile: Square HSS (AISC); (L x W x T) = 4.000 in. x 4.000 in. x 0.125 in. Base material: cracked concrete, 2500, fc' = 2500 psi; h = 48.000 in. Reinforcement: tension: condition A, shear: condition A; edge reinforcement: none or < No. 4 bar Geometry [in.] & Loading [lb, in.lb] HILTI DOES NOT HAVE A ROUND CONCRETE BASE PROFILE. A SQUARE WITH 6.146" MAINTAINS THE SAME CRITICAL EDGE DISTANCE. ANALYSIS FOR ANCHOR CAPACITY ONLY. SEE CALCULATIONS FOR DEMANDS AND DEMAND/CAPACITY RATIOS FOR THIS SITE. 2020-161485 12/15/20 www.hilti.us Profis Anchor 2.7.5 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Company: Specifier: Address: Phone I Fax: E-Mail: | Page: Project: Sub-Project I Pos. No.: Date: 2 6/27/2019 2 Proof I Utilization (Governing Cases) Design values [lb] Utilization Loading Proof Load Capacity bbbbN / bbbb V [%] Status Tension Concrete Breakout Strength 11658 11733 100 / - OK Shear Concrete edge failure in direction x+ 1000 5349 - / 19 OK Loading bbbbN bbbbV z z z z Utilization bbbbN,V [%] Status Combined tension and shear loads 0.994 0.187 1.0 99 OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Shear Capacity per bolt = 5349#/4 = 1337# Tension capacity per bolt = 11733#/2 = 5866# 2020-161485 12/15/20 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSION Page 1 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E This document is used to demonstrate compliance with requirements in §110.9, §130.0, §130.2, §140.7, and §141.0(b)2L for outdoor lighting scopes using the prescriptive path. Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 A. GENERAL INFORMATION 01 Project Location (city) Santa Ana 04 Total Illuminated Hardscape Area (ft2) 42,221 02 Climate Zone 4 03 Outdoor Lighting Zone per Title 24, Part 1 §10-114 or as designated by Authority Having Jurisdiction (AHJ): LZ-0: Very Low - Undeveloped Parkland LZ-2: Moderate - Rural Areas LZ-4: High - Must be reviewed by CA Energy Commission for Approval LZ-1: Low - Developed Parkland LZ-3: Moderately High - Urban Areas✔ B. PROJECT SCOPE Table Instructions: Include any outdoor lighting systems that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in §140.7 or §141.0(b)2L for alterations. My project consists of: 01 02 New Lighting System Must Comply with Allowances from §140.7. Altered Lighting System ✔ Is your alteration increasing the connected lighting load (Watts)? Yes No 03 04 05 % of Existing Luminaires Being Altered¹ Sum Total of Luminaires Being Added or Altered Calculation Method ≥ 10% and < 50% ≥ 50%✔ < 10% 45 Calculated Allowance per §140.7 ¹ FOOTNOTES: % of Existing Luminaires Being Altered = (Sum Total of Luminaires Being Added or Altered / Existing Luminaires within the Scope of the Permit Application) x 100 C. COMPLIANCE RESULTS Table Instructions: If any cell on this table says "DOES NOT COMPLY" or "COMPLIES with Exceptional Conditions" refer to Table D. for guidance. Calculation of Total Allowed Lighting Power (Watts) §140.7 or §141.0(b)2L 01 02 03 04 05 06 General Hardscape Allowance §140.7(d)1 + Per Application §140.7(d)2 + Sales Frontage §140.7(d)2 + Ornamental §140.7(d)2 + Per Specific Area §140.7(d)2 OR Existing Power §141.0(b)2L = (See Table I) (See Table J) (See Table K) (See Table L) (See Table M) (See Table N) Compliance Results 07 08 09 Total Allowed (Watts) ≥ Total Actual (Watts) 07 Must be ≥ 08 (See Table F) 1,083.525 + 240 + + 548.873 + 422.21 OR = 2,294.608 ≥ 2,225.4 COMPLIES Cutoff Compliance (See Table G for Details) COMPLIES Controls Compliance (See Table H for Details) COMPLIES with Exceptional Conditions 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 2 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 D. EXCEPTIONAL CONDITIONS This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. Table F. Outdoor Lighting Fixture Schedule Permit Applicant Notes: UU5: Fixture is necessary for compliance with AB 244, banking security law; ECEMPTION 3 to 130.2(b). Table H. Outdoor Lighting Controls Permit Applicant Notes: Sidewalk Lighting : Lighting is required for compliance to California Finance Code Section 13000-13070 for footcandle requirements for ATM's. Dimming fixtures would lower footcandles to below minimum requirements. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. F. OUTDOOR LIGHTING FIXTURE SCHEDULE Table Instructions: For new or altered lighting systems demonstrating compliance with §140.7 (ie Table I has expanded for input), include all luminaires being installed and any existing luminaires remaining or being moved within the spaces covered by the permit application in the Table below. For altered lighting systems using the Existing Power method per §141.0(b)2L (ie Table N has expanded for input), include only new luminaires being installed and replacement luminaires being installed as part of the project scope (ie, do not include existing luminaires remaining or existing luminaires being moved). Designed Wattage: 01 Name or Item Tag 02 Complete Luminaire Description 03 Watts per luminaire1,2 04 How Wattage is determined 05 Total number luminaires² 06 Luminaire Status³ 07 Excluded per §140.7(a) 08 Design Watts 09 Cutoff Req. ≥ 6,200 initial lumen output §130.2(b)⁴ 10 Field Inspector Pass Fail BO1 Canopy Mount Fixture Linear 20 Mfr. Spec¹ 4 Altered 80 NA: <6,200 lumens B02 Canopy Mount Fixture Linear 20 Mfr. Spec¹ 3 New 60 NA: <6,200 lumens DX1 Canopy Mount Fixture Linear 11 Mfr. Spec¹ 9 Altered 99 NA: <6,200 lumens DX2 Canopy Mount Fixture Linear 11 Mfr. Spec¹ 6 New 66 NA: <6,200 lumens DZ1 Canopy Mount Fixture Linear 19.6 Mfr. Spec¹ 1 Altered 19.6 NA: <6,200 lumens EK1 Ressed Canopy Mount Linear 32 Mfr. Spec¹ 2 Altered 64 NA: <6,200 lumens SA1 Wall Mount Fixture Linear 25 Mfr. Spec¹ 3 Altered 75 NA: <6,200 lumens Table Continued 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 3 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 01 Name or Item Tag 02 Complete Luminaire Description 03 Watts per luminaire1,2 04 How Wattage is determined 05 Total number luminaires² 06 Luminaire Status³ 07 Excluded per §140.7(a) 08 Design Watts 09 Cutoff Req. ≥ 6,200 initial lumen output §130.2(b)⁴ 10 Field Inspector Pass Fail SH1 Wall Mount Fixture Linear 25 Mfr. Spec¹ 5 Altered 125 NA: <6,200 lumens UU1 Pole Mount Fixture Linear 74.3 Mfr. Spec¹ 2 Altered 148.6 NA: <6,200 lumens UU2 Pole Mount Fixture Linear 74.3 Mfr. Spec¹ 3 New 222.9 NA: <6,200 lumens UU3 Pole Mount Fixture Linear 136.4 Mfr. Spec¹ 3 New 409.2 Yes UU4 Pole Mount Fixture Linear 189 Mfr. Spec¹ 3 New 567 Yes UU5 Pole Mount Fixture Linear 289.1 Mfr. Spec¹ 1 New 289.1 Exempt* Linear 0 Total Designed Watts: 2,225.4 * NOTES: Selections with a * require a note in the space below explaining how compliance is achieved. EX: Luminaire is lighting a statue; EXCEPTION 2 to §130.2(b). UU5 Fixture is necessary for compliance with AB 244, banking security law; ECEMPTION 3 to 130.2(b). ¹ FOOTNOTES: Authority Having Jurisdiction may ask for Luminaire cut sheets to confirm wattage used for compliance per §130.0(c) ² For linear luminaires, wattage should be indicated as W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 05 instead of number of luminaires. ³ Select “New” for new luminaires in a new outdoor lighting project or for added luminaires in an alteration. Select “Altered” for replacement luminaires in an alteration. Select “Existing to Remain” for existing luminaires within the project scope that are not being altered and are remaining. Select “Existing Reinstalled” for existing luminaires which are being removed and reinstalled as part of the project scope ⁴ Compliance with mandatory cutoff requirements is required for luminaires with initial lumen output ≥ 6,200 unless exempted by §130.2(b). G. CUTOFF REQUIREMENTS (BUG) Table Instructions: Complete this table for fixtures of ≥ 6,200 initial luminaire lumens indicated on Table F as needing to comply with Cutoff Requirements. Maximum lumens can be found in Title 24, Part 11, Section 5.106.8. Table Continued 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 4 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 01 Name or Item Tag 02 Complete Luminaire Description Backlight Rating² Mounting Height from Property Line¹ 05 03 Backlight Rating Per Design Max Allowable Backlight Rating³ 04 Lighting Type Max Allowable Backlight Rating³ Uplight Rating² 06 07 08 Uplight Rating Per Design 09 10 11 Glare Rating Per Design Max Allowable Glare Rating³ Mounting Height from Property Line¹ Glare Rating² 12 Field Inspector Pass Fail UU3 Canopy Moun > 2 MH from property line> 2 MH from property line No Limit B1 Area LightingArea Lighting U0 U0 > 2 MH from property> 2 MH from property line G3 G3 UU4 Pole Mount F > 2 MH from property line> 2 MH from property line No Limit B1 Area LightingArea Lighting U0 U0 > 2 MH from property> 2 MH from property line G3 G3 ¹ FOOTNOTES: Mounting Height is labeled MH in this table ² Authority having jurisdiction may ask for luminaire cut sheets or other documentation to confirm luminaire type, uplight ratings and glare ratings used for compliance per §130.2(b). ³ BUG ratings with a lower number than the 'Max Allowable' are compliant. Ex. If Max Allowable is Bug Rating is B4, then B0, B1, B2, B3 and B4 are all compliant. H. OUTDOOR LIGHTING CONTROLS Table Instructions: Complete this table demonstrating compliance with controls requirements for all new or altered luminaires installed as part of the permit application. For alteration projects, luminaires which are existing to remain (ie untouched) and luminaires which are removed and reinstalled (wiring only) do not need to be included in this table even if they are within the spaces covered by the permit application. When an option having a * is selected, the notes section of this table must be completed. The lighting controls section of the Compliance Summary Table on the first page will show "DOES NOT COMPLY" if the notes are left blank. For each requirement in columns 02 through 04, do not leave the field blank, instead select NA or Exempt* from the dropdown list to indicate not applicable or an exemption. Mandatory Controls 01 Area Description 02 Shut-Off §130.2(c)1 03 Auto-Schedule §130.2(c)2 04 Motion Sensor §130.2(c)3 05 Field Inspector Pass Fail Sidewalk Lighting Photocontrol Yes - EMCS Exempt * *NOTES: Controls with a * require a note in the space below explaining how compliance is achieved. EX: Not permitted by health & safety to be turned off; EXCEPTION 1 to §130.2(c). Table Continued 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 5 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 01 Area Description 02 Shut-Off §130.2(c)1 03 Auto-Schedule §130.2(c)2 04 Motion Sensor §130.2(c)3 05 Field Inspector Pass Fail Sidewalk Lighting Lighting is required for compliance to California Finance Code Section 13000-13070 for footcandle requirements for ATM's. Dimming fixtures would lower footcandles to below minimum requirements. I. LIGHTING POWER ALLOWANCE (per §140.7) Table Instructions: Please complete this table for areas using the allowance calculations per §140.7. General Hardscape Allowance is per Table 140.7-A while "Use it or lost it" Allowances are per Table 140.7-B. Indicate which allowances are being used to expand sections for user input. Luminaires that qualify for one of the "Use it or lose it" allowances shall not qualify for another "Use it or lose it" allowance. 01 General Hardscape Allowance ✔ Per Application ✔ Sales Frontage Ornamental ✔ Per Specific Area✔ "Use it or lose it" Allowances (select all that apply) Table I (below) Table J Table K Table L Table M Calculated General Hardscape Lighting Power Allowance per Table 140.7-A (LZ 2 & 3) 02 04 05 06 Area Wattage Allowance (AWA) Area Description Illuminated Area (ft²) Allowed Density (W/ft²) Area Allowance (Watts) 03 Surface Type 07 08 09 Linear Wattage Allowance (LWA) Perimeter Length (lf) Allowed Density (W/lf) Linear Allowance (Watts) 10 Total General AWA + LWA (Watts) Sidewalk Concrete 5,600 0.03 168 0.4 0 168 Parking Area Asphalt 36,621 0.025 915.525 0.25 0 915.525 Initial Wattage Allowance for Entire Site (Watts): Total General Hardscape Allowance (Watts): 1,083.525 J. LIGHTING ALLOWANCE: PER APPLICATION Table Instructions: Please complete this table for areas using the wattage allowance per application from Table-140.7-B. Table Continued 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 6 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 01 Area Description 02 Application per Table 140.7-B¹ 03 # of Locations Allowance per Location² (Watts) Extra Allowance (Watts) CALCULATED ALLOWANCE (Watts) 04 05 06 Luminaire Name or Item Tag DESIGN WATTS Watts per Luminaire³ 07 # of Luminaires³ 08 Design Watts 09 10 Additional Allowance (Watts) ATM Machine 5 100 240 BO1 20 4 80 0 B02 20 3 60 0 DX1 11 11 121 0 DX2 11 1 11 0 DZ1 19.6 3 58.8 Total Design Watts for this Area: 330.8 240 Total Allowance (Watts) All Areas: 240 ¹ FOOTNOTES: Primary entrance applications are only available for senior care facilities, healthcare facilities, police stations, hospitals, fire stations, and emergency vehicle facilities. ² The Allowance per Location for ATMs is 100W for the first ATM and 35W for each additional per Table 140.7-B. ³ For luminaires indicated in Table F as linear, wattage in column 07 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 08 instead of number of luminaires. K. LIGHTING ALLOWANCE: SALES FRONTAGE This Section Does Not Apply L. LIGHTING ALLOWANCE: ORNAMENTAL Table Instructions: Please complete this table for areas using the wattage allowance for Hardscape Ornamental Lighting from Table-140.7-B. 01 Area Description 02 Illuminated Area (ft2) Allowed Density (W/ft2) Extra Allowance (Watts) CALCULATED ALLOWANCE (Watts) 03 04 05 Luminaire Name or Item Tag Watts per Luminaire1,2 # of Luminaires² DESIGN WATTS 06 07 Design Watts 08 09 Additional Allowance (Watts) 42,221 0.013 548.873 UU5 289.1 2 578.2 Total Design Watts for this Area: 578.2 548.873 Table Continued 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 7 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 Total Allowance (Watts) Ornamental: 548.873 ¹ FOOTNOTES: Luminaires qualifying for this allowance shall be rated < 100W and shall be post-top luminaires, lanterns, pendants or chandeliers. ² For luminaires indicated in Table F as linear, wattage in column 06 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 07 instead of number of luminaires. M. LIGHTING ALLOWANCE: PER SPECIFIC AREA Table Instructions: Please complete this table for areas using the wattage allowance per specific area type from Table 140.7-B. More than one specific area allowance may be taken in a single project, if applicable. However, multiple specific area allowances may not be taken for the exact same area on the site. 01 Area Description 02 Specific Area Type per Table 140.7-B 03 Specific Area (ft2)¹ Allowed Density (W/ft2) Extra Allowance (Watts) CALCULATED ALLOWANCE (Watts) 04 05 06 Luminaire Name or Item Tag Watts per Luminaire² # of Luminaires² DESIGN WATTS 07 08 09 Design Watts 10 Additional Allowance (Watts) parking Lot Lighting Security for Retail Parking & Pedestrian Hardscape 42,221 0.01 422.21 UU4 189 3 567 Total Design Watts for this Area: 567 422.21 Total Allowance (Watts) All Areas: 422.21 ¹ FOOTNOTES: See Table 140.7-B for the rules for calculating the specific areas (ft²) for these additional lighting allowances. ² For luminaires indicated in Table F as linear, wattage in column 07 is W/lf instead of Watts/luminaire. Total linear feet for the luminaire should be indicated in column 08 instead of number of luminaires. N. EXISTING CONDITIONS POWER ALLOWANCE (alterations only) This Section Does Not Apply 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSI19 Page 8 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 ● ● O. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Table Instructions: Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and can be found online at https://www.energy.ca.gov/ title24/2019standards/2019_compliance_documents/Nonresidential_Documents/NRCI/ YES NO Form/Title Field Inspector Pass Fail NRCI-LTO-01-E - Must be submitted for all buildings. NRCI-LTO-02-E - Must be submitted for a lighting control system; or for an Energy Management Control System (EMCS), to be recognized for compliance. ● P. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE Table Instructions: Selections have been made based on information provided in previous tables of this document. If any selection needs to be changed, please explain why in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and must be completed through an Acceptance Test Technician Certification Provider (ATTCP). For more information visit: http://www.energy.ca.gov/title24/attcp/providers.html YES NO Form/Title Field Inspector Pass Fail NRCA-LTO-02-A - Must be submitted for all outdoor lighting controls except for alterations where controls area added to ≤ 20 luminaires. 2020-161485 12/15/20 CA Building Energy Efficiency Standards - 2019 Nonresidential Compliance: http://www.energy.ca.gov/title24/2019standards April 2019 STATE OF CALIFORNIA Outdoor Lighting NRCC-LTO-E (Created 4/19) CALIFORNIA ENERGY COMMISSION Page 9 of 9 CERTIFICATE OF COMPLIANCE NRCC-LTO-E Project Name: Bank of America 2020 Exterior Lighting Program CA6-204 Report Page: Project Address: 3730 S Bristol St. Date Prepared: 08/31/2020 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT Documentation Author Name: Jonathan D. Gentry Documentation Author Signature: Company: Craig L. Molnar Signature Date: 08/31/2020 Address: 10927 Crabapple Road CEA/ HERS Certification Identification (if applicable): City/State/Zip: Roswell, GA 30075 Phone: 770-992-5077 RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Craig L. Molnar Responsible Designer Signature: Company : Craig L. Molnar Date Signed: 08/31/2020 Address: 10927 Crabapple Road License: E15519 City/State/Zip: Roswell, GA 30075 Phone: 770-992-5077 2020-161485 12/15/20