4609 W El Don Pl - Plan
DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 SAFETY LABELS PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN AP P E N D I X ELECTRICAL CALCULATIONS MODULE DATASHEET INVERTER DATASHEET ARRAY WIRING BOX DATASHEET DISCONNECT DATASHEETS MOUNTING SYSTEM DATASHEET MOUNTING SYSTEM ENGINEERING LETTER UL 2703 CLASS A FIRE CERTIFICATION UL 2703 GROUNDING AND BONDING CERTIFICATION ANCHOR DATASHEET PROJECT DETAILS PROPERTY OWNER NEENA NGUYEN PROPERTY ADDRESS 4609 W EL DON PL, SANTA ANA, CA 92704 APN 108-102-13 ZONING RESIDENTAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) AHJ CITY OF SANTA ANA UTILITY COMPANY SOUTHERN CALIFORNIA EDISON CO ELECTRICAL CODE 2019 CEC FIRE CODE 2019 CFC OTHER BUILDING CODES 2019 CA BUILDING CODE 2019 CA RES. BUILDING CODE 2019 CA PLUMBING CODE 2019 CA MECHANICAL CODE 2019 CA FUEL GAS CODE 2019 CA ENERGY CODE CONTRACTOR INFORMATION COMPANY PREMIER BUILDERS LICENSE NUMBER 995068 (B) ADDRESS 8832 LA GRAND AVE, GARDEN GROVE, CA 92841 PHONE NUMBER (714) 653-8019 CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED TO DESCRIBE THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE DC RATING OF SYSTEM 2.64KW AC OUTPUT RATINGS 1.74KW, 7.3A INVERTER(S)6 X ENPHASE IQ8PLUS-72-2-US MODULE URECO FAM440E8G-BB ARRAY WIRING (1) BRANCH OF 6 IQ8PLUS-72-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF INTERCONNECTION NEW SUPPLY SIDE AC CONNECTION PER CEC 705.12(A) AT AUXILIARY INPUT OF SOLAR-READY MAIN PANEL UTILITY SERVICE 120/240V 1Φ ELECTRICAL PANEL 10A BREAKER INSTALLED IN SUPPLY SIDE AUXILIARY INPUT OF SOLAR- READY MAIN SERVICE PANEL SITE DESIGN PARAMETERS ASHRAE EXTREME LOW 3°C (38°F) ASHRAE 2% HIGH 32°C (89°F) CLIMATE DATA SOURCE JOHN WAYNE AIRPORT WIND (ASCE 7-16)95 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II P-525014 GR I D - T I E D S O L A R P O W E R S Y S T E M NG U Y E N R E S I D E N C E 46 0 9 W E L D O N P L SA N T A A N A , C A 9 2 7 0 4 PROJECT SUMMARY DOC ID:ED8F10-3 DATE:5/13/22 CREATOR:B.H. REVIEWER: REVISIONS PV-1 BLDG # 101111434 ELECT # 20176939 ISSUED: 09/21/2022 4609 W El Don Pl - 10111143409/21/22 PV MODULE MICROINVERTER 6 IN BRANCH PM1-6 440W 1 2 3 4 5 6 7 JUNCTION BOX JB1 1 AC DISCONNECT 2 SW1 30A AC COMBINER COMM GATEWAY 3 CB1 10A C1 8 9 PV DISCONNECT SW2 30A 4 SQUARE D DU221RB MAIN SERVICE PANEL AC GEC LO A D S BIDIRECTIONAL UTILITY METERKWHR LOAD LINE KWHR LOAD LINE HOMELINE 120/240V 1ɸ, 3W 225A BUSBAR (TOP-FED) 200A MAIN BREAKER 30A-RATED AUX. INPUT 200A CB2-4 10A 10 11 MODULES REF. QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-6 6 URECO FAM440E8G-BB 440W 411W 11.34A 10.74A 49.6V 41.0V -0.1339V/°C (-0.27%/°C)20A INVERTERS REF. QTY.MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-6 6 ENPHASE IQ8PLUS-72-2-US 240V NOT SOLIDLY GROUNDED 290W 1.2A 15.0A 60V 97.0% PASS-THRU BOXES AND COMBINERS REF. QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1 1 GENERIC GEN-AWB-TB-1-4X OR EQUIV.30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER 4C OR EQUIV.64A 240VAC DISCONNECTS REF. QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1-2 2 SQUARE D DU221RB OR EQUIV.30A 240VAC OCPDS REF. QTY.RATED CURRENT MAX VOLTAGE CB1-2 2 10A 240VAC F1-2 2 10A 240VAC SYSTEM SUMMARY INVERTERS PER BRANCH 6 MAX AC CURRENT 7.26A MAX AC OUTPUT 1,740W ARRAY STC POWER 2,640W ARRAY PTC POWER 2,465W MAX AC CURRENT 7A MAX AC POWER OUTPUT 1,740W DERATED AC POWER OUTPUT 1,740W NOTES RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER CEC 690.12(B). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER CEC 690.12(B).2 THE DC AND AC CONNECTORS OF THE ENPHASE IQ8PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY CEC 690.15(D). MATING CONNECTORS SHALL COMPLY WITH CEC 690.33. 3 INVERTER IS COMPLIANT WITH CALIFORNIA PUBLIC UTILITIES COMMISSION RULE 21 FOR SMART INVERTERS. INSTALLER SHALL CONFIGURE INVERTER TO OPERATE IN REACTIVE POWER PRIORITY MODE.4 DC PV CONDUCTORS ARE NOT SOLIDLY-GROUNDED. NO DC PV CONDUCTOR SHALL BE WHITE- OR GRAY-COLORED5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY CEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO CEC 690.47(A) AND CEC 250.169 AND INSTALLED IN COMPLIANCE WITH CEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 52.5V AT 3°C (3.3°C - 25°C) X -0.134V/C + 49.6V = 52.5V).7 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH CEC 705.12(B)(2)(3)(C).8 THE ENPHASE IQ COMBINER 4C CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 15A.9 POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT USING AUXILIARY ENERGY INPUT OF SOLAR-READY MAIN SERVICE PANEL, IN COMPLIANCE WITH CEC 705.12(A).10 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH CEC 230.72. 11 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN. V.D. 1 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.76 (52°C) 1.0 7.26A 9.07A 30A 23A 75°C 25A 23.7FT 0.28% 2 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% 3 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% 4 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE: GR I D - T I E D S O L A R P O W E R S Y S T E M SA N T A A N A , C A 9 2 7 0 4 46 0 9 W E L D O N P L PV-3 P-525014 05/13/22 B.H. ED8F10-3 SINGLE-LINE DIAGRAM NG U Y E N R E S I D E N C E 1 PV-3 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 4609 W El Don Pl - 10111143409/21/22 C1 - AC COMBINER (ENPHASE IQ COMBINER 4C) SW1 - DISCONNECT (SQUARE D DU221RB) SW2 - DISCONNECT (SQUARE D DU221RB) MSP - MAIN SERVICE PANEL (HOMELINE) SEE NOTE NO. 4 (MSP) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. CEC690.56(C)(1) AND CFC1204.5.1 AC COMBINER PANEL (C1) ! WARNING ! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. CEC705.12(B)(2)(3)(C) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1, SW2) ! WARNING ! ELECTRIC SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. CEC690.13(B) AC SOLAR DISCONNECT (SW2 IN NULL, SW1 IN NULL) PV SYSTEM DISCONNECT CEC690.13(B) AC DISCONNECT (SW2 IN NULL, SW1 IN NULL) MAXIMUM AC OPERATING CURRENT: 7.3A MAXIMUM AC OPERATING VOLTAGE: 240V CEC690.54 ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. CEC705.12(B)(3) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2019 CEC AND 2019 CFC WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH CEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH CEC 690.56(B). 4 LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY," SHALL BE LOCATED WITHIN 3 FT OF SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8″ IN BLACK ON A YELLOW BACKGROUND, AND REMAINING TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16″ IN BLACK ON WHITE BACKGROUND P-525014 GR I D - T I E D S O L A R P O W E R S Y S T E M NG U Y E N R E S I D E N C E 46 0 9 W E L D O N P L SA N T A A N A , C A 9 2 7 0 4 SAFETY LABELS DOC ID:ED8F10-3 DATE:5/13/22 CREATOR:B.H. REVIEWER: REVISIONS PV-4 4609 W El Don Pl - 10111143409/21/22 C1 - AC COMBINER (ENPHASE IQ COMBINER 4C) SW1 - DISCONNECT (SQUARE D DU221RB) SW2 - DISCONNECT (SQUARE D DU221RB) MSP - MAIN SERVICE PANEL (HOMELINE) SEE NOTE NO. 4 (MSP) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. CEC690.56(C)(1) AND CFC1204.5.1 AC COMBINER PANEL (C1) ! WARNING ! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. CEC705.12(B)(2)(3)(C) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1, SW2) ! WARNING ! ELECTRIC SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. CEC690.13(B) AC SOLAR DISCONNECT (SW2 IN NULL, SW1 IN NULL) PV SYSTEM DISCONNECT CEC690.13(B) AC DISCONNECT (SW2 IN NULL, SW1 IN NULL) MAXIMUM AC OPERATING CURRENT: 7.3A MAXIMUM AC OPERATING VOLTAGE: 240V CEC690.54 ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. CEC705.12(B)(3) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2019 CEC AND 2019 CFC WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH CEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH CEC 690.56(B). 4 LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY," SHALL BE LOCATED WITHIN 3 FT OF SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8″ IN BLACK ON A YELLOW BACKGROUND, AND REMAINING TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16″ IN BLACK ON WHITE BACKGROUND P-525014 GR I D - T I E D S O L A R P O W E R S Y S T E M NG U Y E N R E S I D E N C E 46 0 9 W E L D O N P L SA N T A A N A , C A 9 2 7 0 4 SAFETY LABELS DOC ID:ED8F10-3 DATE:5/13/22 CREATOR:B.H. REVIEWER: REVISIONS PV-4 4609 W El Don Pl - 10111143409/21/22 GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER CEC 110.26. 2 24/7 UNESCORTED KEYLESS ACCESS SHALL BE PROVIDED TO ALL SOUTHERN CALIFORNIA EDISON CO EQUIPMENT. 3 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 4 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. 5 ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE A RAINTIGHT FIT, PER CEC 358.42. (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 4/12 (18.4°) SLOPED ROOF, 6 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 340° AZIMUTH (N) TRANSITION BOX (JB1), OUTDOOR, OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) DISCONNECT (SW1), OUTDOOR (N) VISIBLE-OPEN TYPE, LOCKABLE, READILY ACCESSIBLE, LABELED PV SYSTEM DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER (SW2), OUTDOOR (N) AC COMBINER (C1), OUTDOOR, OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN EMT CONDUIT OVER ROOF NO CLOSER THAN 7/8″ ABOVE ROOF SURFACE (E) UTILITY METER, OUTDOOR (E) MAIN SERVICE PANEL (MSP), OUTDOOR ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-525014 GR I D - T I E D S O L A R P O W E R S Y S T E M NG U Y E N R E S I D E N C E 46 0 9 W E L D O N P L SA N T A A N A , C A 9 2 7 0 4 SITE PLAN DOC ID:ED8F10-3 DATE:5/13/22 CREATOR:B.H. REVIEWER: REVISIONS PV-2 4609 W El Don Pl - 10111143409/21/22 PV MODULE MICROINVERTER 6 IN BRANCH PM1-6 440W 1 2 3 4 5 6 7 JUNCTION BOX JB1 1 AC DISCONNECT 2 SW1 30A AC COMBINER COMM GATEWAY 3 CB1 10A C1 8 9 PV DISCONNECT SW2 30A 4 SQUARE D DU221RB MAIN SERVICE PANEL AC GEC LO A D S BIDIRECTIONAL UTILITY METERKWHR LOAD LINE KWHR LOAD LINE HOMELINE 120/240V 1ɸ, 3W 225A BUSBAR (TOP-FED) 200A MAIN BREAKER 30A-RATED AUX. INPUT 200A CB2-4 10A 10 11 MODULES REF. QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-6 6 URECO FAM440E8G-BB 440W 411W 11.34A 10.74A 49.6V 41.0V -0.1339V/°C (-0.27%/°C)20A INVERTERS REF. QTY.MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-6 6 ENPHASE IQ8PLUS-72-2-US 240V NOT SOLIDLY GROUNDED 290W 1.2A 15.0A 60V 97.0% PASS-THRU BOXES AND COMBINERS REF. QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE JB1 1 GENERIC GEN-AWB-TB-1-4X OR EQUIV.30A 240VAC / 600VDC C1 1 ENPHASE IQ COMBINER 4C OR EQUIV.64A 240VAC DISCONNECTS REF. QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1-2 2 SQUARE D DU221RB OR EQUIV.30A 240VAC OCPDS REF. QTY.RATED CURRENT MAX VOLTAGE CB1-2 2 10A 240VAC F1-2 2 10A 240VAC SYSTEM SUMMARY INVERTERS PER BRANCH 6 MAX AC CURRENT 7.26A MAX AC OUTPUT 1,740W ARRAY STC POWER 2,640W ARRAY PTC POWER 2,465W MAX AC CURRENT 7A MAX AC POWER OUTPUT 1,740W DERATED AC POWER OUTPUT 1,740W NOTES RAPID SHUTDOWN DEVICES COMPLIANT WITH REQUIREMENTS AS PER CEC 690.12(B). PV CIRCUIT CONDUCTORS LOCATED OUTSIDE THE ARRAY BOUNDARY (DEFINED AS 3 FEET FROM THE POINT OF PENETRATION INTO A BUILDING OR MORE THAN 3 FEET FROM AN ARRAY) SHALL BE LIMITED TO NOT MORE THAN 30V WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION. CONDUCTORS LOCATED INSIDE OF THE ARRAY BOUNDARY SHALL BE LIMITED TO NOT MORE THAN 80 VOLTS WITHIN 30 SECONDS OF SHUTDOWN. 1 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER CEC 690.12(B).2 THE DC AND AC CONNECTORS OF THE ENPHASE IQ8PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY CEC 690.15(D). MATING CONNECTORS SHALL COMPLY WITH CEC 690.33. 3 INVERTER IS COMPLIANT WITH CALIFORNIA PUBLIC UTILITIES COMMISSION RULE 21 FOR SMART INVERTERS. INSTALLER SHALL CONFIGURE INVERTER TO OPERATE IN REACTIVE POWER PRIORITY MODE.4 DC PV CONDUCTORS ARE NOT SOLIDLY-GROUNDED. NO DC PV CONDUCTOR SHALL BE WHITE- OR GRAY-COLORED5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY CEC 250.4(B) AND PART III OF ARTICLE 250 AND DC EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO CEC 690.47(A) AND CEC 250.169 AND INSTALLED IN COMPLIANCE WITH CEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS EXPECTED TO BE 52.5V AT 3°C (3.3°C - 25°C) X -0.134V/C + 49.6V = 52.5V).7 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH CEC 705.12(B)(2)(3)(C).8 THE ENPHASE IQ COMBINER 4C CONTAINS A FACTORY-INSTALLED COMMUNICATIONS GATEWAY WITH AN OCPD RATED NO MORE THAN 15A.9 POINT-OF-CONNECTION IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT USING AUXILIARY ENERGY INPUT OF SOLAR-READY MAIN SERVICE PANEL, IN COMPLIANCE WITH CEC 705.12(A).10 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH CEC 230.72. 11 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYP CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT/CABLE. OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING LEN. V.D. 1 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.76 (52°C) 1.0 7.26A 9.07A 30A 23A 75°C 25A 23.7FT 0.28% 2 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% 3 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% 4 1 12 AWG THWN-2, COPPER 0.5" DIA. EMT 2 10A 12 AWG THWN-2, COPPER 0.96 (32°C) 1.0 7.26A 9.07A 30A 29A 75°C 25A 48IN 0.05% REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE: GR I D - T I E D S O L A R P O W E R S Y S T E M SA N T A A N A , C A 9 2 7 0 4 46 0 9 W E L D O N P L PV-3 P-525014 05/13/22 B.H. ED8F10-3 SINGLE-LINE DIAGRAM NG U Y E N R E S I D E N C E 1 PV-3 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). 4609 W El Don Pl - 10111143409/21/22 C1 - AC COMBINER (ENPHASE IQ COMBINER 4C) SW1 - DISCONNECT (SQUARE D DU221RB) SW2 - DISCONNECT (SQUARE D DU221RB) MSP - MAIN SERVICE PANEL (HOMELINE) SEE NOTE NO. 4 (MSP) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. CEC690.56(C)(1) AND CFC1204.5.1 AC COMBINER PANEL (C1) ! WARNING ! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. CEC705.12(B)(2)(3)(C) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1, SW2) ! WARNING ! ELECTRIC SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. CEC690.13(B) AC SOLAR DISCONNECT (SW2 IN NULL, SW1 IN NULL) PV SYSTEM DISCONNECT CEC690.13(B) AC DISCONNECT (SW2 IN NULL, SW1 IN NULL) MAXIMUM AC OPERATING CURRENT: 7.3A MAXIMUM AC OPERATING VOLTAGE: 240V CEC690.54 ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. CEC705.12(B)(3) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2019 CEC AND 2019 CFC WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH CEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH CEC 690.56(B). 4 LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY," SHALL BE LOCATED WITHIN 3 FT OF SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8″ IN BLACK ON A YELLOW BACKGROUND, AND REMAINING TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16″ IN BLACK ON WHITE BACKGROUND P-525014 GR I D - T I E D S O L A R P O W E R S Y S T E M NG U Y E N R E S I D E N C E 46 0 9 W E L D O N P L SA N T A A N A , C A 9 2 7 0 4 SAFETY LABELS DOC ID:ED8F10-3 DATE:5/13/22 CREATOR:B.H. REVIEWER: REVISIONS PV-4 4609 W El Don Pl - 10111143409/21/22 STRUCTURAL DESIGN PARAMETERS ELEVATION 66 FT SEISMIC 1.062 SDS WIND (ASCE 7-16)95 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 0 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 4/12 (18.4°) MEAN ROOF HEIGHT 13.9FT ROOF DECKING 15/32" OSB CONSTRUCTION RAFTERS (2X10'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL URECO FAM440E8G-BB DIMENSIONS (AREA) 83.0IN X 41.3IN X 1.4IN (23.8 SQ FT) WEIGHT 53.8LB MOUNTING SYSTEM PROPERTIES RAIL MODEL IRONRIDGE XR10 ANCHOR MODEL IRONRIDGE FV-01-B1 (FLASHED), 3.38IN AIR GAP FASTENING METHOD 2.5 INCH EMBEDMENT INTO RAFTERS WITH (1) 5/16IN DIA. FASTENER GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 6 53.8 322.8 MICROINVERTERS 6 1.1 6.5 LINEAR FEET OF RAIL 86 FT 0.4 37.5 ANCHORS 24 0.6 14.4 MISC. HARDWARE 5.4 5.4 TOTAL ARRAY WEIGHT 386.6 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 6 23.8 142.8 POINT LOAD (386.6 LBS / 24 ATTACHMENTS) 16.1 LBS DIST. LOAD (386.6 LBS / 142.8 SQFT)2.71 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. CONTRACTOR MAY NEED TO MAKE MINOR ADJUSTMENTS TO ANCHOR LOCATIONS. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE RAIL SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER ZONES 1, 2E, 2N, 2R, 3E NORMAL 92.0IN 72.0IN 36.8IN ZONE 3R NORMAL 90.0IN 72.0IN 36.0IN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 3.0 ft = max(min(0.4 * 13.9 ft, 0.1 * 23.6 ft), 0.04 * 23.6 ft, 3 ft) P-525014 GR I D - T I E D S O L A R P O W E R S Y S T E M NG U Y E N R E S I D E N C E 46 0 9 W E L D O N P L SA N T A A N A , C A 9 2 7 0 4 ATTACHMENT PLAN DOC ID:ED8F10-3 DATE:5/13/22 CREATOR:B.H. REVIEWER: REVISIONS PV-5 4609 W El Don Pl - 10111143409/21/22 48 4609 W El Don Pl - 10111143409/21/22 GENERAL NOTES 1 AT LEAST TWO 3′-WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS, WITH AT LEAST ONE PATHWAY ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PV ARRAY, AT LEAST ONE SUCH PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE, OR ON AN ADJACENT ROOF PLANE, OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. (CFC 1204.2.1.1) 2 FOR PV ARRAYS OCCUPYING 33% OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A MIN. 18″-WIDE SETBACK IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. (CFC 1204.2.1.2) 3 PV MODULES SHALL NOT BE PLACED BELOW AN EMERGENCY ESCAPE/RESCUE OPENING. A 3′-WIDE PATHWAY SHALL BE PROVIDED TO SUCH AN OPENING. (CFC 1204.2.2) ROOF ACCESS POINT PV MODULES INSTALLED ON ROOF WITH IRONRIDGE ROOF MOUNTING SYSTEM. 3.0′ WIDE FIRE ACCESS PATHWAY, PER CFC 1204.2.1.1 1.5′ WIDE SMOKE-VENTILATION SETBACK, PER CFC 1204.2.1.2 TOTAL PLAN VIEW ARRAY AREA IS 135.3 SQ.FT, WHICH REPRESENTS 17.2% OF TOTAL PLAN VIEW ROOF AREA (789.0 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-525014 GR I D - T I E D S O L A R P O W E R S Y S T E M NG U Y E N R E S I D E N C E 46 0 9 W E L D O N P L SA N T A A N A , C A 9 2 7 0 4 FIRE SAFETY PLAN DOC ID:ED8F10-3 DATE:5/13/22 CREATOR:B.H. REVIEWER: REVISIONS PV-7 4609 W El Don Pl - 10111143409/21/22 Conductor, Conduit, and OCPD Sizing Validation 1. Maximum System DC Voltage Test 1.1. Enphase inverter w/6 Ureco FAM440E8G-BB (440W)s Array Properties Array Type Microinverter Array System Description Enphase inverter w/6 Ureco FAM440E8G-BB (440W)s Module FAM440E8G-BB (440W) Highest number of modules in series in a PV Source Circuit 1 Design Low Temp.3.3°C Module voc 49.6V Temp. Coefficient voc -0.134V/C CEC Code Calculations A. Maximum Voltage of PV Source Circuit 52.51V see 690.7(A) CEC 690.7(A) requires that if the PV module manufacturer provides a temperature coefficient of open-circuit voltage, it must be used to calculate the PV array's maximum system voltage. It includes an information note recommending the use of the ASHRAE 'Extreme Annual Mean Minimum Design Dry Bulb Temperature' as the design low temperature. Using these values, the module Voc (49.6V) will increase to 52.51V at the design low temperature ( 3.3°C). (3.3°C - 25°C) X -0.134V/C + 49.6V = 52.51V The module Voc at the design low temperature is 52.51V. 52.51V X 1 = 52.51V CEC Code Validation Tests 1. PV Source Circuit maximum Voc must not exceed 600V 52.51V < 600V = true PASS 2. Wire, Conduit, and OCPD Code Compliance Validation 2.1. #1: AC Branch Output: Transition Box to AC Disconnect Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 10A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 52°C Power Source Description Branch of 6 IQ8PLUS-72-2-US microinverters Power Source Current 7.26A Voltage 240V CEC Code Calculations A. Continuous Current 7.26A see Article 100 Equipment maximum rated output current is 6 X 1.21A = 7.26A B. Ampacity of Conductor 30A see Table 310.15(B)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 23A see Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100 The temperature factor for 90°C insulation at 52°C is 0.76. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.76) and by the fill factor (1). 30A X 0.76 X 1 = 22.8A rounded to 23A D. Max Current for Terminal Temp. Rating 25A see 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 25A. E. Minimum Allowed OCPD Rating 9A see 240.4 CEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 7.26A X 1.25 = 9.07A rounded down to 9A F. Maximum Allowed OCPD Rating 20A see 240.4(D) CEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 10A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") CEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (240.4) 10 >= 7.26A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (240.4) 23A >= 10A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (240.4) 10 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (Article 100) 23A >= 7.26A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (215.2(A)(1)) 30A > 7.26A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (110.14(C)) 25A >= 7.26A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (Table 250.122) 12 AWG >= 14 AWG = true PASS 8. Conduit must meet code recommendation for minimum size (300.17) 0.5in. >= 0.5in. = true PASS 4609 W El Don Pl - 10111143409/21/22 2.2. #2: AC Disconnect Output: AC Disconnect to AC Combiner Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 10A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 32°C Power Source Description Branch of 6 IQ8PLUS-72-2-US microinverters Power Source Current 7.26A Voltage 240V CEC Code Calculations A. Continuous Current 7.26A see Article 100 Equipment maximum rated output current is 6 X 1.21A = 7.26A B. Ampacity of Conductor 30A see Table 310.15(B)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100 The temperature factor for 90°C insulation at 32°C is 0.96. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 25A see 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 25A. E. Minimum Allowed OCPD Rating 9A see 240.4 CEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 7.26A X 1.25 = 9.07A rounded down to 9A F. Maximum Allowed OCPD Rating 20A see 240.4(D) CEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 10A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") CEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (240.4) 10 >= 7.26A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (240.4) 29A >= 10A (OCPD Rating) = true PASS 3. OCPD rating must not exceed max OCPD rating for conductor (240.4) 10 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (Article 100) 29A >= 7.26A = true PASS 5. Conductor Ampacity must be at least 125% of Continuous Current (215.2(A)(1)) 30A > 7.26A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (110.14(C)) 25A >= 7.26A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (Table 250.122) 12 AWG >= 14 AWG = true PASS 8. Conduit must meet code recommendation for minimum size (300.17) 0.5in. >= 0.5in. = true PASS 2.3. #3: AC Combiner Output: AC Combiner to Utility Disconnect Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 10A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 32°C Power Source Description Enphase inverter w/6 Ureco FAM440E8G-BB (440W)s Power Source Current 7.26A Voltage 240V CEC Code Calculations A. Continuous Current 7.26A see Article 100 Equipment maximum rated output current is 7.26A B. Ampacity of Conductor 30A see Table 310.15(B)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100 The temperature factor for 90°C insulation at 32°C is 0.96. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 25A see 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 25A. E. Minimum Allowed OCPD Rating 9A see 240.4 CEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 7.26A X 1.25 = 9.07A rounded down to 9A F. Maximum Allowed OCPD Rating 20A see 240.4(D) CEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 10A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") CEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (240.4) 10 >= 7.26A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (240.4) 29A >= 10A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (240.4) 10 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (Article 100) 29A >= 7.26A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (215.2(A)(1)) 30A > 7.26A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (110.14(C)) 25A >= 7.26A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (Table 250.122) 12 AWG >= 14 AWG = true PASS 8. Conduit must meet code recommendation for minimum size (300.17) 0.5in. >= 0.5in. = true PASS 4609 W El Don Pl - 10111143409/21/22 2.4. #4: Utility Disconnect Output: Utility Disconnect to Main Service Panel Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 10A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 32°C Power Source Description Enphase inverter w/6 Ureco FAM440E8G-BB (440W)s Power Source Current 7.26A Voltage 240V CEC Code Calculations A. Continuous Current 7.26A see Article 100 Equipment maximum rated output current is 7.26A B. Ampacity of Conductor 30A see Table 310.15(B)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100 The temperature factor for 90°C insulation at 32°C is 0.96. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 25A see 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 25A. E. Minimum Allowed OCPD Rating 9A see 240.4 CEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 7.26A X 1.25 = 9.07A rounded down to 9A F. Maximum Allowed OCPD Rating 20A see 240.4(D) CEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 10A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") CEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (240.4) 10 >= 7.26A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (240.4) 29A >= 10A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (240.4) 10 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (Article 100) 29A >= 7.26A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (215.2(A)(1)) 30A > 7.26A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (110.14(C)) 25A >= 7.26A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (Table 250.122) 12 AWG >= 14 AWG = true PASS 8. Conduit must meet code recommendation for minimum size (300.17) 0.5in. >= 0.5in. = true PASS 4609 W El Don Pl - 10111143409/21/22 Key Features FAM_E8G-BB / 144 cells 425W - 445 W Mono-Crystalline PV Module EN URE Peach module uses URE state-of -the art cell cutting technology, and advanced module manufacturing experiences. Positive power tolerance +0 ~ +5 watt 100% EL inline inspection Better module reliability Withstand heavy loading front load 5400 Pa & rear load 2400 Pa Excellent lo w light performance 3.5% relative eff. Reduction at low (200W/m²) Design for 1000 VDC Reduce the system BOS effectively www.urecorp.com For more information, please visit us at www.urecorp.com Copyright © 2021 URE Corp. All rights reserved EN Engineering Drawing (mm)Dependence on Irradiance Reliability with Warranty 1 year 98.0% 100% 90% 80% 0% 0 5 10 15 Years Li n e a r p e r f o r m a n c e w a r r a n t y 20 25 URE Additional value from warranty Standard tiered warranty 25 year 80.0% Electrical Data *Standard Test Condition (STC): Cell Temperature 25 °C, Irradiance 1000 W/m², AM 1.5 *Values without tolerance are typical numbers.Measurement tolerance: ± 3% Model - STC Maximum Rating Power (Pmax) Module Efficiency Open Circuit Voltage (Voc) Maximum Power Voltage Short Circuit Current (Isc) Maximum Power Current [W] [%] [V] [V] [A] [A] FAM425E8G-BB 19.24 425 49.00 40.40 11.11 10.52 FAM430E8G-BB 19.46 430 49.20 40.60 11.19 10.60 FAM435E8G-BB 19.69 435 49.40 40.80 10.67 11.26 FAM440E8G-BB 19.92 440 49.60 41.00 10.74 11.34 Item Mechanical Load Maximum System Voltage Series Fuse Rating Operating Temperature Specification 5400 Pa 1000V 20 A -40 to 85 °C 45°C ± 2°C 0.048 % / °C -0.27 % / °C -0.35 % / °C Temperature Characteristics Item Nominal Module Operating Temperature Temperature Coefficient of Isc Temperature Coefficient of Voc Temperature Coefficient of Pmax Specification Operating ConditionsMechanical Data Item Dimensions Weight Solar Cell Front Glass Junction Box Specification Package Configuration 31 pcs Per Pallet, 682 pcs per 40’ HQ container 2108 mm (L)1 x 1048 mm (W) 1 x 35 mm (D)2 / 82.99� (L)1 x 41.26� (W)1 x 1.38� (D)2 24.4 kg / 53.79 lbs 12x12 pieces monocrystalline solar cells series strings White toughened safety glass, 3.2mm thickness IP ≥ 68, 3 diodes : With assembly tolerance of ± 2 mm [ ± 0.08�] : With assembly tolerance of ± 0.8 mm [ ± 0.03�]2 1 Cable & Connector Potrait : 500 mm (cable length can be customized), 1 x 4 mm2 compatible with MC4 *Nominal module operating temperature (NMOT): Air mass AM 1.5, irradiance 800W/m², temperature 20°C, windspeed 1 m/s. *Reduction in efficiency from 1000W/m² to 200W/m² at 25°C: 3.5 ± 2%. Cell Encapsulation EVA (Ethylene-Viny-Acetate) Frame Black anodized aluminum profile 0 2 4 6 8 10 12 0 5 10 15 20 25 30 35 40 45 50 55 Cu r r e n t [ A ] Voltage [V] Temperature 25oC 600 W/m2 800 W/m2 1000 W/m2 400 W/m2 200 W/m2 C 1048±1 FRONT VIEW A A 998±1 BACK VIEW C-Mounting Hole 8 place D-Mounting Hole 4 place 9 7 1008±1 35 A-A Frame D Note:mm B B 10 B-B Frame FAM445E8G-BB 20.14 445 49.80 41.20 10.81 11.42 25 Output warranty Years 25 Product Gurantee Years Taipei Office e-mail : sales@urecorp.com Tel : +886-2-2656-2000 Fax : +886-2-2656-0593 Headquarters No. 7, Li-Hsin 3rd Road, Hsinchu Science Park Hsinchu city 30078, Taiwan Tel : +886-3-578-0011 Fax : +886-3-578-1255 For more information, please visit us at www.urecorp.com URECO_US_Peach_FAM_E8G-BB_V1_3.2_35mm_BS_EN_210520Copyright © 2021 URE Corp. All rights reserved 9F, No. 295, Tiding Blvd. Sec. 2 Taipei, Taiwan 11493 4609 W El Don Pl - 10111143409/21/22 IQ8 Series Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) requirements © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8SE-DS-0001-01-EN-US-2021-10-19 DATA SHEET (1) The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 Series Microinverters INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US1 Commonly used module pairings2 W 235 – 350 235 – 440 260 – 460 295 – 500 320 – 540+ 295 – 500+ Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27 – 37 29 – 45 33 – 45 36 – 45 38 – 45 38 – 45 Operating range V 25 – 48 25 – 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current3 [module Isc]A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/range4 V 240 / 211 – 264 208 / 183 – 250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 Max units per 20 A (L-L) branch circuit5 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency %97 97 97 97.5 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SE-DS-0001-01-EN-US-2021-10-19 4609 W El Don Pl - 10111143409/21/22 X-IQ-AM1-240-4 The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 4/4C X-IQ-AM1-240-4 X-IQ-AM1-240-4C To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom, back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed X-IQ-AM1-240-4C To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. 10-21-2021 MODEL NUMBER IQ Combiner 4 (X-IQ-AM1-240-4)IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C (X-IQ-AM1-240-4C)IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Ensemble Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for Ensemble sites - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating 65 A Max. continuous current rating (input from PV/storage)64 A Max. fuse/circuit rating (output)90 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)80A of distributed generation / 95A with IQ Gateway breaker included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT)A pair of 200 A split core current transformers MECHANICAL DATA Dimensions (WxHxD)37.5 x 49.5 x 16.8 cm (14.75” x 19.5” x 6.63”). Height is 21.06" (53.5 cm) with mounting brackets. Weight 7.5 kg (16.5 lbs) Ambient temperature range -40º C to +46º C (-40º to 115º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 4/4C 4609 W El Don Pl - 10111143409/21/22 Product data sheet Characteristics DU221RB SWITCH NOT FUSIBLE GD 240V 30A 2P NEMA3R Stock Code: Stock - Normally stocked in distribution facility Price*: 177.00 USD Main Product Single Throw Safety Switch Current Rating 30 A Certifications UL listed Enclosure Rating NEMA 3R Disconnect Type Non-fusible disconnect Factory Installed Neutral None Mounting Type Surface Number of Poles 2 Electrical Connection Lugs Duty Rating General duty Ordering and shipping details Category 00106 - D & DU SW,NEMA3R, 30-200A Discount Schedule DE1A GTIN 00785901490340 Nbr. of units in pkg.1 Package weight(Lbs)4.8600000000000003 Returnability Y Country of origin MX Contractual warranty Period 18 months Product Life Status : Commercialised Th e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d / o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n . Th i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s . It i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f . Ne i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n . Ne i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n . * P r i c e s a r e i n d i c a t i v e Feb 1, 2018 1 4609 W El Don Pl - 10111143409/21/22 Flush Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Assistant Online software makes it simple to create, share, and price projects. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. 25-Year Warranty Products guaranteed to be free of impairing defects. Built for solar’s toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Datasheet © 2019 IronRidge, Inc. All rights reserved. U.S. Patents: #8,695,290; #9,819,303; #9,865,938; Others Pending. Version 1.70 XR Rails Attachments Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear and black finish Bonded Splices All rails use internal splices for seamless connections. • Self-drilling screws • Varying versions for rails • Forms secure bonding XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear and black finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist-on Cap eases install • Wind-driven rain tested • Mill and black finish Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear and black finish Slotted L-Feet Clamps & Grounding UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish CAMO Bond modules to rails while staying completely hidden. • Universal end-cam clamp • Tool-less installation • Fully assembled NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16” socket • Assembled and lubricated Bonding Hardware CONTINUING EDUCATION REGISTERED PROVIDER Flash and mount conduit, strut, or junction boxes. • Twist-on Cap eases install • Wind-driven rain tested • Secures ¾” or 1” conduit Conduit Mount Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction 4609 W El Don Pl - 10111143409/21/22 © 2021 IronR idge, Inc. CA Flush Mount System Certification Letter - 1 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com Attn: Corey Geiger, COO, IronRidge Inc. Date: July 1st, 2021 Re: Structural Certification and Span Tables for the IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidges Flush Mount System. The contents of the letter shall be read in its entirety before applying to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8 stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) 2018 International Building Code (IBC-2018) 2019 California Building Code (CBC-2019) 2015 Aluminum Design Manual (ADM-2015) Report SEAOC (Structural Engineer Association of California) PV2-2017 Wind Design for Solar Arrays The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones provided in ASCE 7-16 for gable & hip roof profiles, and roof slopes of 8° to 45°. The tabulated spans are applicable when the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener). 2. Each module shall be supported by 2 rails (2 rail system) or 3 rails (3 rail system). Spans are calculated based on 2 rail systems, and conservatively deemed acceptable for 3 rail systems. 3. The underlying roof slope, measured between the roof surface and horizontal plane, is 8º to 45º. 4. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 5. A clearance from the underside of the array to the roof surface of 2 minimum shall be provided and the height of the array, the distance from the module top surface to the roof surface (defined as h 2 ), shall not exceed 10. 6. Module length and area shall not exceed the maximum values listed on the respective span tables. 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidges Flush Mount Installation Manual and other applicable standards for the general roof construction practice. © 2021 IronRidge, Inc. CA Flush Mount System Certification Letter - 4 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, SE Senior Structural Engineer 2021.07.14 17:00:22 -07'00' 4609 W El Don Pl - 10111143409/21/22 © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 2 RATINGS Product markings are located on the Grounding Lug bolt head. MARKINGS UL 2703 LISTeD Conforms to STD UL 2703 Standard for Safety First edition: Mounting Systems, Mounting Devices, Clamping/ Retention Devices, and Ground Lugs for Us e with Flat-Plat e Photovoltaic Modules and Panels • Max Overcurrent Protective Device (OCPD) Rating: 40A • Max Module Size: 30.5 ft² • Module Orientation: Portrait or Landscape • System Design Load Rating: 10 PSF downward, 5 PSF upward, 5 PSF lateral • Actual system structural capacity including spans and cantilevers are defined by PE stamped certification letters. • CAMO Specific Design Load rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral Certified to CSA TIL No. A-40 Photovoltaic Module Racking Systems • Load Rating: 2400 PA [50 PSF] CLASS A SYSTeM FIRe RATING PeR UL 2703 • Any Roof Slope with Module Types 1, 2, 3, 13, 19, 25 & 29. • Any module-to-roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third-party attachment. • Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating. WATeR SeAL RATINGS: • UL 441 (Flashfoot2, All Tile Hook, Knockout Tile, Flashvue, L-Mount) • TAS 100(A)-95 (Flashfoot2, All Tile Hook, Knockout Tile, Flashvue, L-Mount, Qbase) • Tested and evaluated without sealant. • Any roofing manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12 STRUCTURAL CeRTIFICATION • Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 FLORIDA PRODUCT APPROVAL #FL29843 • Conforms to TAS202, TAS100(A) • Approved for installation both inside and outside High Velocity Hurricane Zones (HVHZ) • Allowable design pressure up to +100/-100 PSF • Additional details and full list of approved components can be found Here. #5003807 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) Signature: Name: Nalini Mandadi Position: Project Engineer Date: 11/14/2014 In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address: IronRidge, Inc. 28357 Industrial Blvd Hayward, CA 94545 USA Product Description: Flush Mount System with XR Rails. Ratings & Principle Characteristics: Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2, 3, 13, 19, 25 and 29 listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5” gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is applicable with any IronRidge or 3’rd party roof anchor. Models: IronRidge Flush Mount with XR Rails Brand Name:IronRidge Flush Mount Relevant Standards : UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 Date of Tes ts: 08/27/2014 to 03/17/2015 Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1, 104428358MID-001 EEV Revision Summary 8/27/2020 Added type 13, 19, 25 and 29 to system, update address. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chris Zimbrich Reviewed by: Chad Naggs Title: Technician I, Fire Resistance Title: Technical Team Lead, Fire Resistance Signature: Signature: Date: 08/27/2020 Date: 08/27/2020 4609 W El Don Pl - 10111143409/21/22 © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 21 MODULe COMPATIBILITY MAKe MODeLS 7KH)OXVK0RXQW6\VWHPPD\EHXVHGWRJURXQGDQGRUPRXQWD39PRGXOHFRPSO\LQJZLWK8/RQO\ZKHQWKHVSHFL¿FPRGXOHKDV EHHQHYDOXDWHGIRUJURXQGLQJDQGRUPRXQWLQJLQFRPSOLDQFHZLWKWKHLQFOXGHGLQVWUXFWLRQV8QOHVVRWKHUZLVHQRWHG³[[[´UHIHUVWRWKH PRGXOHSRZHUUDWLQJDQGERWKEODFNDQGVLOYHUIUDPHVDUHLQFOXGHGLQWKHFHUWL¿FDWLRQ FRAMeD MODULe LIST Adani Adani modules with 35 and 40mm frames $6;<==[[[ :KHUH;FDQEH%0RU3<FDQEHRUDQG==FDQEHEODQN3(5&%3(5&RU$%3(5& Aionrise Aionrise modules with 35 and 40mm frames $,21\\*[[[ :KHUH\\FDQEHRU Amerisolar Amerisolar modules with 35, 40 and 50 mm frames $6E<[[[= :KHUHEFDQEHRU<FDQEH03030RU3DQG=FDQEHEODQN:RU:% Aptos Solar Aptos modules with 35 and 40 mm frames DNA-yy-zzaa-xxx :KHUH\\FDQEHRU]]FDQEH0)RU%)DQGDDFDQEHRU Astronergy Solar Astronergy modules with 30, 35, 40, and 45 mm frames DD60EE\\&]][[[ :KHUH³DD´FDQEH&+RU$EEFDQEHRU³\\´FDQEHEODQNRU&FDQ030%/ 0+&0%/+&3+&0'*RU0'*7DQG³]]´FDQEHEODQN+9)%RU)%+ ASUN ASUN modules with 35 and 40 mm frames $681[[[<<==DD :KHUH<<FDQEHRU==FDQEH0RU0+DQGDDFDQEHEODQNRU%% Auxin Auxin modules with 40 mm frames AXN6y6zAxxxB :KHUH\FDQEH0RU3]FDQEHRUDQG$FDQEH)0RU7DQG%FDQEHEODQN$ B or C Axitec Axitec Modules with 30, 35 and 40 mm frames $&[[[<DD==E :KHUH<FDQEH030%RU0+DDFDQEHEODQNRU==FDQEHRU EFDQEH6;99%;9RU0; Boviet Boviet modules with 35 and 40mm frames %90==DD<<[[[%FF :KHUH==FDQEHRUDDFDQEHRU<<LV0RU3DQG%FDQEHEODQN/RU6DQGFF FDQEHEODQN++%)+%)'*++&++&%)++&%)'*+&%)RU+&%)'* BYD BYD modules with 35 mm frames %<'[[[$<== :KHUH$FDQEH030+RU3+<FDQEH&RU.DQG==FDQEHRU Canadian Solar Canadian Solar modules with 30, 32, 35 and 40 mm frames &6E<[[[= :KHUHEFDQEHRU<FDQEH+./1389:;RU<DQG=FDQEH03063;06' P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD CertainTeed CertainTeed modules with 35 and 40 frames &7[[[<==$$ :KHUH<FDQEH03RU+&==FDQEHRUDQG$$FDQEHRU CSUN Csun modules with 35 and 40 mm frames YYxxx-zzAbb :KHUH<<LV&681RU667]]LVEODQNRUDQG$LVEODQN30RU00EELVEODQN%%%% BW, or ROOF Dehui Dehui modules with 30, 35 and 40mm frames '+0<<<=[[[ :KHUH³<<<´FDQEHDQG³=´FDQEH%)RU: © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 22 MODULe COMPATIBILITY Ecosolargy Ecosolargy modules with 35, 40, and 50 mm frames ECOxxxYzzA-bbD :KHUH³<´FDQEH$+6RU7³]]´FDQEHRU³$´FDQEH0RU3³EE´FDQEHRUDQG³'´FDQ be blank or B ET Solar ET Solar modules with 30, 35, 40, and 50 mm frames (7<===[[[$$ :KHUH<FDQEH3/RU0===FDQEH%+%+%+%+%+DQG$$FDQ EH*/7%7::%::%%:%*::*:%$&:%&2::&2::%&2RU%%$& Flex Flex modules with 35, 40, and 50 mm frames );6[[[<<== :KHUH³<<´FDQEH%%RU%&DQG³==´FDQEH0$$%0$$:0$%:6$$%6$$:6$&% 6$&:6$':6%$%6%$:6%&%RU6%&: *&/ *&/PRGXOHVZLWKPPDQGPPIUDPHV *&/DE<<[[[ :KHUH³D´FDQEH0RU3³E´FDQEHRUDQG³<<´FDQEH+RU'+ GigaWatt Solar Gigawatt modules with 40 mm frames GWxxxYY :KHUH³<<´FDQEHHLWKHU3%RU0% +DQVRO +DQVROPRGXOHVZLWKDQGIUDPHV +6[[[<<]] :KHUH³<<´FDQEH3%3'3(7%7'8%8'RU8(DQG³]]´FDQEH$+$1$1$1+++9 RU-+ +DQZD6RODU +DQZKD6RODUPRGXOHVZLWKDQGPPIUDPHV +6/DD3<<[[[= :KHUH³DD´FDQEHHLWKHURU³<<´FDQEH3$RU3%DQG³=´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or X +\XQGDL +\XQGDLPRGXOHVZLWKDQGPPIUDPHV +L<6[[[== :KHUH<FDQEH$'RU66FDQEH0RU6DQG==FDQEH*,+*+,.,0,0)0*3,5,5* 5*%)5*%.6*7,RU7* Itek Itek Modules with 40 and 50 mm frames IT-xxx-YY :KHUH³<<´FDQEHEODQN+(RU6(RU6( 4609 W El Don Pl - 10111143409/21/22 © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 23 MODULe COMPATIBILITY JA Solar JA Solar modules with 30, 35, 40 and 45 mm frames -$\\]]EEZZ[[[DD :KHUH³\\´FDQEH030RU3³]]´FDQEHEODQN./59%.)$7*)$5/%./ 7*5%.57*9%.%.7*RU/%.7*³EE´FDQEHRUZZFDQEH ''''6666666666RU6DQG³DD´FDQEH%30% 056,6&35%%%%%%5(%% Jinko Jinko modules with 35 and 40 mm frames -.0<[[[==DD :KHUH<FDQHLWKHUEHEODQNRU6==FDQEH03RU33DQGDDFDQEHEODQN%+/ %/+/+%+%/+%/(3-%-%(33OXV90;5/5/% 7/%5/95/79%-%-3OXV9+9/9+/9+/9+/ 790;+%'93+/79RU+/90; .\RFHUD .\RFHUD0RGXOHVZLWKPPIUDPHV .<[[[==$$ :KHUH³<´FDQEH'RU8³==´FDQEHEODQN*;RU6;DQG³$$´FDQEH/38/)8838/36/3%/)% /)%6/)%/3%$&%&)&$&%&)&8&$&%&)&8&%&)&%&0&$RU 6MPA /* /*PRGXOHVZLWKDQGPPIUDPHV /*[[[<D=EE :KHUH<FDQEH$(0146DFDQEH$RU=FDQEH&.7RU:DQGEEFDQEH$$ $%%(($:**-./199 /RQJL /RQJLPRGXOHVZLWKDQGPPIUDPHV /5D<<==[[[0 :KHUHDFDQEHRU<<FDQEHEODQNRUDQG==FDQEHEODQN%.%3+93%3( 3++%'+,%+,++3%+3+RU+,%' Mission Solar Mission Solar modules with 33, 35 and 40 mm frames <<<EE[[[==DD :KHUH<<<FDQEH06(RU7;6EEFDQEHEODQNRU$==FDQEHEODQN006(626465 6;76RUDQGDDFDQEHEODQN%%%:--6.57-6:=.7RU6 Mitsubishi Mitsubishi modules with 46 mm frames 390<<[[[== :KHUH³<<´FDQEH/(RU-(DQG³==´FDQEHHLWKHU+'+'RU)% Moltech IM and XS series modules with 40, 45, and 50 mm frames Next Energy Alliance Next Energy Alliance modules with 35 and 40mm frames \\1($[[[== ZKHUH³\\´FDQEHEODQNRU86³==´FDQEH00%RU0 Neo Solar Power Neo Solar Power modules with 35 mm frames '<[[[==DD :KHUH³<´FDQEH0RU3³==´FDQEH%$%$($($+$+$DQG³DD´FDQEHEODQN7)0(RU ME (TF) 3DQDVRQLF+,7 Panasonic modules with 35 and 40 mm frames 9%+1[[[<<]]$ :KHUH³<<´FDQEHHLWKHU.$5$6$RU=$³]]´FDQEHHLWKHU%%% %RUDQG³$´FDQEHEODQN(*RU1 Panasonic (EverVolt) Panasonic modules with 30 mm frames EVPVxxxA :KHUH$FDQEHEODQNRU+.RU3. Peimar Peimar modules with 40 mm frames SbxxxYzz :KHUH³E´FDQEH*0RU3³<´FDQEH0RU3DQG³]]´FDQEHEODQN%)RU)% Philadelphia Solar Philadelphia modules with 35 and 40 mm frames PS-YzzAA-xxx :KHUH<FDQEH0RU3]]FDQEHRUDQG$$FDQEHEODQN%)+&RU+&%) Phono Solar Phono Solar modules with 35, 40, and 45 mm frames 36[[[<==$ :KHUH<FDQEH000+0+00+RU3==FDQEHRUDQG$FDQEH)788+RU7+ © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 24 MODULe COMPATIBILITY Recom Recom modules with 35 and 40 mm frames RCM-xxx-6yy :KHUH³\\´FDQEH0$0%0(RU0) REC Solar REC modules with 30, 38 and 45 mm frames 5(&[[[<<== :KHUH³<<´FDQEH$$013133(3(73737307360736730RU73DQG³==´FDQ EHEODQN%ODFN%/.%/.6/9RU3XUH Renesola ReneSola modules with 35, 40 and 50 mm frames $$[[[<== :KHUH$$FDQEH6306/3RU-&<FDQEHEODQN)0RU6DQG==FDQEHEODQN$E$EE$EK $EKE$EY$EYE%E%EE%EK%EKE%EY%EYE'E'EERU%E Renogy Renogy Modules with 40 and 50 mm frames RNG-xxxY :KHUH³[[[´LVWKHPRGXOHSRZHUUDWLQJDQG³<´FDQEH'RU3 Risen Risen Modules with 30, 35 and 40 mm frames 560\\D[[[== :KHUH\\FDQEHRUDFDQEHRUDQG==FDQEH03RU%0'* S-Energy S-Energy modules with 35 and 40mm frames 6$%%&&<<<[[[= :KHUH³$´FDQEH&'/RU1³%%´FDQEHEODQNRU³&&´FDQEHEODQNRU³<<<´FDQ EHEODQN%'(0$(0$,0%(0%,0&(RU0&,DQG³=´FDQEH903RU3 SEG Solar SEG Solar with 30, 35 and 40 mm frames 6(*D<<[[[== :KHUHDFDQEHEODQNRU%<<FDQEHEODQN0$0%3$RU3%DQG==FDQEHEODQN%%%*%: +9:%::%0%%0$+9%0$%*%0$7%%0%7%%0%+9%0'+9%0%%* Seraphim USA Seraphim modules with 30, 35, 40 and 50 mm frames 653[[[<<<== :KHUH[[[LVWKHPRGXOHSRZHUUDWLQJDQG<<<FDQEH%0$%0'0$0%3$3%4$;;;; DQG4%;;;;==LVEODQN%%%*RU+9 Sharp Sharp modules with 35 and 40 mm frames NUYYxxx :KHUH³<<´FDQEH6$ RU6& Silfab Silfab Modules with 35 and 38 mm frames 6<<=[[[$E :KHUH<<FDQEH,/6$/$6*RU/*=FDQEHEODQN03RU;$FDQEHEODQN%+01DQGE FDQEH$&*./178RU; Solaria Solaria modules with 35 and 40 mm frames 3RZHU;7[[[<== :KHUH<FDQEH5RU&DQG==FDQEH$&%'%;%<3'3/3030$&3;3=:;RU:= Solarcity (Tesla) Solarcity modules with 40 mm frames SCxxxYY :KHUH³<<´FDQEHEODQN%RU% SolarTech SolarTech modules with 40 and 42 mm frames AAA-xxxYY :KHUH$$$FDQEH3(5&%%3(5&%:+-7%%+-7%:RU678<<FDQEHEODQN3(5&RU+-7 SolarWorld AG 6RODU:RUOG6XQPRGXOH3OXV3URWHFW%LVXQ;/%LVXQ;/PD\EHIROORZHGE\PRQRSRO\GXREODFNENRU FOHDUPRGXOHVZLWKRUPPIUDPHV SW-xxx 4609 W El Don Pl - 10111143409/21/22 MODULe COMPATIBILITY © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 25 SolarWorld Americas 6RODU:RUOG6XQPRGXOH3OXV3URWHFW%LVXQ;/%LVXQ;/PD\EHIROORZHGE\PRQRSRO\GXREODFNENRU clear; modules with 33 mm frames SWA-xxx Sonali Sonali Modules with 40 mm frames SSxxx Stion 6WLRQ7KLQ¿OPPRGXOHVZLWKPPIUDPHV STO-xxx or STO-xxxA SunEdison 6XQ(GLVRQ0RGXOHVZLWK PPIUDPHV 6(<[[[=$%&'( :KHUH<FDQEH%)+35RU==FDQEHRU$FDQEH%&'(+,-./0RU1%FDQEH%RU :&FDQEH$RU&'FDQEHRUDQG(FDQEHRU Suniva Suniva modules with 35, 38, 40, 46, and 50 mm frames 237[[[$$%<<<= 09;[[[$$%<<<= :KHUH$$LVHLWKHURU%LVHLWKHURU<<<LVHLWKHU%RU%DQG=LVEODQN or B Sunpower Sunpower standard (G3 or G4) or InvisiMount (G5) 35, 40 and 46 mm frames 635=E[[[<< :KHUH=LVHLWKHU$(30RU;³E´FDQEHEODQNRUDQG³<<´FDQEHEODQN%/. &20&$&'$&($&%/.($&*$&%/.&$&RU%/.'$& Sunspark Sunspark modules with 40 mm frames 6<<[[[=$ :KHUH³<<´FDQEH0;RU67DQG³=´FDQEH00%00%3RU:DQG$FDQEHRU Suntech Suntech Modules with 35, 40 and 50mm frames 673[[[\]]DD :KHUH\LVEODQNRU6DQG]]FDQEH$RU$8DQGDDFDQEH9G9HP9IZ9IK:GE:GH Wd, or Wfhb Talesun Talesun modules with 30, 35 and 40mm frames 7$%\==DD[[[E :KHUH$FDQEH'RU3%FDQEHRU \FDQEHEODQN)*+,RU/==FDQEHRU DDFDQEH00+RU3DQGEFDQEHEODQN%7RU+ Tesla Tesla modules with 40 mm frames TxxxY :KHUH<FDQEH+RU6 Trina Trina Modules with 30, 35, 40 and 46mm frames 760[[[<<== :KHUH<<FDQEH'''''''('('(9'(*'(*9&'(0'(*0& '('('(*&'(;3$3&3'3'3$3&3'3(RU3(DQG ==FDQEHEODQN,,,,''666,,$$ $$$,,$,,$,,$,,$,,$,,$,,++,,+,,+,,+&,, +&,,00,,0,,0&,, URE URE modules with 35 mm frames '\=[[[DD :KHUH'FDQEH'RU)\FDQEH$RU=FDQEH.RU0DQGDDFDQEH+$+$+$(*%% E8G or E8G-BB Vikram Vikram solar modules with 40 mm frames 96\\==$$$EE :KHUH\\FDQEH030%%0+060+%%RU3%%==FDQEHRU$$$LVWKHPRGXOHSRZHU UDWLQJDQGEEFDQEHRU VSUN VSUN modules with 30, 35 and 40 mm frames VSUNxxx-YYz-aa :KHUH<<FDQEHRU]FDQEH030+3+RU%0+DQGDDFDQEHEODQN%% BW, or DG MODULe COMPATIBILITY © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 26 MAKe MODeLS FRAMeLeSS MODULe LIST Astronergy Solar Astronergy frameless modules &+603'*[[[ Canadian Solar Canadian Solar frameless modules &6E<[[[= :KHUH³E´FDQEHRU³<´LV.38RU;DQG³=´FDQEH0)*06)*3)*0%)*RU3%)* +HOLHQH +HOLHQHIUDPHOHVVPRGXOHV <<==[[[$ :KHUH<<FDQEH==FDQEH0DQG$FDQEH*+ Jinko Jinko frameless modules -.0[[[33'9 Prism Solar Prism Solar frameless modules %=<<[[[$$$ :KHUH=FDQEHLRU1<<FDQEH6RU6DQG$$$FDQEHEODQNRU%67& Risen Risen frameless modules 560\\[[[== :KHUH³\\´FDQEHRUDQG³==´FDQEH0'*RU3'* Stion Stion frameless modules 67/[[[RU67/[[[$ Sunpreme Sunpreme frameless modules GXB-xxxYY :KHUH³<<´FDQEHEODQNRU6/ Trina Trina frameless modules TSM-xxxYY :KHUH³<<´FDQEHHLWKHU'(*,,'(*,,'(*,,'(*,,'(*,,'(*&,, '(*&,,'(*,,3(*3(*3(*3(*3(*RU3(* Waaree Waaree modules with 40mm frames WSyy-xxx ZKHUH³\\´FDQEHEODQN0RU0% Winaico Winaico modules with 35 and 40 mm frames :V\[[[=D :KHUH\FDQEHHLWKHU3RU7=FDQEHHLWKHU03RU0;DQGDFDQEHEODQNRU Yingli Yingli modules with 35 and 40 mm frames </[[[=\\ :KHUH=FDQEH'RU3\\FDQEHEEGEERUG =16KLQH =16KLQHPRGXOHVZLWKPPIUDPHV =;0<$$$[[[0 :KHUH<FDQEHRU$$$FDQEH1+1+1+'%1+/''6+6+'%RU 6+/'' 4609 W El Don Pl - 10111143409/21/22 Tech Brief Moving Flashing Forward We set out to design a flashing that checked all the boxes: fully waterproof, fast and easy to install correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. The optimized flashing design features a large viewport, for easy alignment with the pilot hole. And the GripCap and GripCap+ sit snugly in place, so the lag can be driven single-handedly. FlashVue™ GripCap & GripCap+ The 360º capable GripCap (2.74” tall) and GripCap+ (3.74” tall) can be placed in any orientation, and provide a “friction-fit” for easy installs. Push snug into the viewport, without worrying it will roll away or rotate while driving the lag. Three-Tier Water Seal, Reimagined FlashVue’s seal architecture utilizes three layers of protection. The viewport is elevated 0.30”, and provides a “friction-fit” for the GripCap. The GripCap fully covers the viewport while a sealing washer adds another layer of protection. And an EPDM washer and lag bolt “seal the deal” in the stack. Large Viewport in Flashing The large viewport makes it easy to align the flashing with the pilot hole, and drive the lag centered into the rafter. The elevated rim not only provides a sturdy dock for the GripCap or GripCap+, but increases water-shedding capabilities. ⌀ 0.75” Triple Certified to Protect the Roof™ UL 2703, 441 (27) TAS 100(A)-95 © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Tech Brief Solve Roof Undulations See Your Pilot Holes Also Available: GripCap+ We know roofs are not always perfectly flat. GripCap+ can help when undulations get in the way. Large Viewport in Flashing FlashVue makes pilot holes highly visible, like never before. No more tedious guesswork on hot roofs. Trusted Strength & Certification Attachment Loading FlashVue has been tested and rated to support 1161 (lbs) of uplift and 353 (lbs) of lateral load. Structural Certification Designed and certified for compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Passed both the UL 441 Section 27 “Rain Test” and TAS 100-95 “Wind Driven Rain Test” by Intertek. UL 2703 Listed System Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info. 4609 W El Don Pl - 10111143409/21/22 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 2.4. #4: Utility Disconnect Output: Utility Disconnect to Main Service Panel Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 10A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 32°C Power Source Description Enphase inverter w/6 Ureco FAM440E8G-BB (440W)s Power Source Current 7.26A Voltage 240V CEC Code Calculations A. Continuous Current 7.26A see Article 100 Equipment maximum rated output current is 7.26A B. Ampacity of Conductor 30A see Table 310.15(B)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100 The temperature factor for 90°C insulation at 32°C is 0.96. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 25A see 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 25A. E. Minimum Allowed OCPD Rating 9A see 240.4 CEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 7.26A X 1.25 = 9.07A rounded down to 9A F. Maximum Allowed OCPD Rating 20A see 240.4(D) CEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 10A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") CEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (240.4) 10 >= 7.26A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (240.4) 29A >= 10A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (240.4) 10 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (Article 100) 29A >= 7.26A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (215.2(A)(1)) 30A > 7.26A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (110.14(C)) 25A >= 7.26A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (Table 250.122) 12 AWG >= 14 AWG = true PASS 8. Conduit must meet code recommendation for minimum size (300.17) 0.5in. >= 0.5in. = true PASS 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Key Features FAM_E8G-BB / 144 cells 425W - 445 W Mono-Crystalline PV Module EN URE Peach module uses URE state-of -the art cell cutting technology, and advanced module manufacturing experiences. Positive power tolerance +0 ~ +5 watt 100% EL inline inspection Better module reliability Withstand heavy loading front load 5400 Pa & rear load 2400 Pa Excellent lo w light performance 3.5% relative eff. Reduction at low (200W/m²) Design for 1000 VDC Reduce the system BOS effectively www.urecorp.com For more information, please visit us at www.urecorp.com Copyright © 2021 URE Corp. All rights reserved EN Engineering Drawing (mm)Dependence on Irradiance Reliability with Warranty 1 year 98.0% 100% 90% 80% 0% 0 5 10 15 Years Li n e a r p e r f o r m a n c e w a r r a n t y 20 25 URE Additional value from warranty Standard tiered warranty 25 year 80.0% Electrical Data *Standard Test Condition (STC): Cell Temperature 25 °C, Irradiance 1000 W/m², AM 1.5 *Values without tolerance are typical numbers.Measurement tolerance: ± 3% Model - STC Maximum Rating Power (Pmax) Module Efficiency Open Circuit Voltage (Voc) Maximum Power Voltage Short Circuit Current (Isc) Maximum Power Current [W] [%] [V] [V] [A] [A] FAM425E8G-BB 19.24 425 49.00 40.40 11.11 10.52 FAM430E8G-BB 19.46 430 49.20 40.60 11.19 10.60 FAM435E8G-BB 19.69 435 49.40 40.80 10.67 11.26 FAM440E8G-BB 19.92 440 49.60 41.00 10.74 11.34 Item Mechanical Load Maximum System Voltage Series Fuse Rating Operating Temperature Specification 5400 Pa 1000V 20 A -40 to 85 °C 45°C ± 2°C 0.048 % / °C -0.27 % / °C -0.35 % / °C Temperature Characteristics Item Nominal Module Operating Temperature Temperature Coefficient of Isc Temperature Coefficient of Voc Temperature Coefficient of Pmax Specification Operating ConditionsMechanical Data Item Dimensions Weight Solar Cell Front Glass Junction Box Specification Package Configuration 31 pcs Per Pallet, 682 pcs per 40’ HQ container 2108 mm (L)1 x 1048 mm (W) 1 x 35 mm (D)2 / 82.99� (L)1 x 41.26� (W)1 x 1.38� (D)2 24.4 kg / 53.79 lbs 12x12 pieces monocrystalline solar cells series strings White toughened safety glass, 3.2mm thickness IP ≥ 68, 3 diodes : With assembly tolerance of ± 2 mm [ ± 0.08�] : With assembly tolerance of ± 0.8 mm [ ± 0.03�]2 1 Cable & Connector Potrait : 500 mm (cable length can be customized), 1 x 4 mm2 compatible with MC4 *Nominal module operating temperature (NMOT): Air mass AM 1.5, irradiance 800W/m², temperature 20°C, windspeed 1 m/s. *Reduction in efficiency from 1000W/m² to 200W/m² at 25°C: 3.5 ± 2%. Cell Encapsulation EVA (Ethylene-Viny-Acetate) Frame Black anodized aluminum profile 0 2 4 6 8 10 12 0 5 10 15 20 25 30 35 40 45 50 55 Cu r r e n t [ A ] Voltage [V] Temperature 25oC 600 W/m2 800 W/m2 1000 W/m2 400 W/m2 200 W/m2 C 1048±1 FRONT VIEW A A 998±1 BACK VIEW C-Mounting Hole 8 place D-Mounting Hole 4 place 9 7 1008±1 35 A-A Frame D Note:mm B B 10 B-B Frame FAM445E8G-BB 20.14 445 49.80 41.20 10.81 11.42 25 Output warranty Years 25 Product Gurantee Years Taipei Office e-mail : sales@urecorp.com Tel : +886-2-2656-2000 Fax : +886-2-2656-0593 Headquarters No. 7, Li-Hsin 3rd Road, Hsinchu Science Park Hsinchu city 30078, Taiwan Tel : +886-3-578-0011 Fax : +886-3-578-1255 For more information, please visit us at www.urecorp.com URECO_US_Peach_FAM_E8G-BB_V1_3.2_35mm_BS_EN_210520Copyright © 2021 URE Corp. All rights reserved 9F, No. 295, Tiding Blvd. Sec. 2 Taipei, Taiwan 11493 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 IQ8 Series Microinverters Our newest IQ8 Microinverters are the industry’s first microgrid-forming, software- defined microinverters with split-phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor-based microinverter is our proprietary application-specific integrated circuit (ASIC) which enables the microinverter to operate in grid-tied or off-grid modes. This chip is built in advanced 55nm technology with high speed digital logic and has super-fast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the Enphase IQ Battery, Enphase IQ Gateway, and the Enphase App monitoring and analysis software. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power-on testing, enabling an industry-leading limited warranty of up to 25 years. Connect PV modules quickly and easily to IQ8 Series Microinverters using the included Q-DCC-2 adapter cable with plug-n-play MC4 connectors. IQ8 Series Microinverters are UL Listed as PV Rapid Shut Down Equipment and conform with various regulations, when installed according to manufacturer’s instructions. Easy to install • Lightweight and compact with plug-n-play connectors • Power Line Communication (PLC) between components • Faster installation with simple two-wire cabling High productivity and reliability • Produce power even when the grid is down • More than one million cumulative hours of testing • Class II double-insulated enclosure • Optimized for the latest high- powered PV modules Microgrid-forming • Complies with the latest advanced grid support • Remote automatic updates for the latest grid requirements • Configurable to support a wide range of grid profiles • Meets CA Rule 21 (UL 1741-SA) requirements © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ8 microinverters, and other names are trademarks of Enphase Energy, Inc. Data subject to change. IQ8SE-DS-0001-01-EN-US-2021-10-19 DATA SHEET (1) The IQ8H-208 variant will be operating in grid-tied mode only at 208V AC. (2) No enforced DC/AC ratio. See the compatibility calculator at https://link.enphase.com/module-compatibility (3) Maximum continuous input DC current is 10.6A (4) Nominal voltage range can be extended beyond nominal if required by the utility. (5) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8 Series Microinverters INPUT DATA (DC)IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US1 Commonly used module pairings2 W 235 – 350 235 – 440 260 – 460 295 – 500 320 – 540+ 295 – 500+ Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell MPPT voltage range V 27 – 37 29 – 45 33 – 45 36 – 45 38 – 45 38 – 45 Operating range V 25 – 48 25 – 58 Min/max start voltage V 30 / 48 30 / 58 Max input DC voltage V 50 60 Max DC current3 [module Isc]A 15 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration 1x1 Ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)IQ8-60-2-US IQ8PLUS-72-2-US IQ8M-72-2-US IQ8A-72-2-US IQ8H-240-72-2-US IQ8H-208-72-2-US Peak output power VA 245 300 330 366 384 366 Max continuous output power VA 240 290 325 349 380 360 Nominal (L-L) voltage/range4 V 240 / 211 – 264 208 / 183 – 250 Max continuous output current A 1.0 1.21 1.35 1.45 1.58 1.73 Nominal frequency Hz 60 Extended frequency range Hz 50 – 68 Max units per 20 A (L-L) branch circuit5 16 13 11 11 10 9 Total harmonic distortion <5% Overvoltage class AC port III AC port backfeed current mA 30 Power factor setting 1.0 Grid-tied power factor (adjustable)0.85 leading – 0.85 lagging Peak efficiency %97.5 97.6 97.6 97.6 97.6 97.4 CEC weighted efficiency %97 97 97 97.5 97 97 Night-time power consumption mW 60 MECHANICAL DATA Ambient temperature range -40ºC to +60ºC (-40ºF to +140ºF) Relative humidity range 4% to 100% (condensing) DC Connector type MC4 Dimensions (HxWxD)212 mm (8.3”) x 175 mm (6.9”) x 30.2 mm (1.2”) Weight 1.08 kg (2.38 lbs) Cooling Natural convection – no fans Approved for wet locations Yes Acoustic noise at 1 m <60 dBA Pollution degree PD3 Enclosure Class II double-insulated, corrosion resistant polymeric enclosure Environ. category / UV exposure rating NEMA Type 6 / outdoor COMPLIANCE Certifications CA Rule 21 (UL 1741-SA), UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. IQ8SE-DS-0001-01-EN-US-2021-10-19 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 X-IQ-AM1-240-4 The Enphase IQ Combiner 4/4C with Enphase IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure and streamlines IQ microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Enphase IQ Combiner 4/4C X-IQ-AM1-240-4 X-IQ-AM1-240-4C To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Networking Smart • Includes IQ Gateway for communication and control • Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • Includes solar shield to match Enphase IQ Battery aesthetics and deflect heat • Flexible networking supports Wi-Fi, Ethernet, or cellular • Optional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Centered mounting brackets support single stud mounting • Supports bottom, back and side conduit entry • Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed X-IQ-AM1-240-4C To learn more about Enphase offerings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. 10-21-2021 MODEL NUMBER IQ Combiner 4 (X-IQ-AM1-240-4)IQ Combiner 4 with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes a silver solar shield to match the IQ Battery system and IQ System Controller 2 and to deflect heat. IQ Combiner 4C (X-IQ-AM1-240-4C)IQ Combiner 4C with Enphase IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and consumption monitoring (+/- 2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Ensemble Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan for Ensemble sites - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 4/4C XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Gateway printed circuit board (PCB) for Combiner 4/4C X-IQ-NA-HD-125A Hold down kit for Eaton circuit breaker with screws. ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating 65 A Max. continuous current rating (input from PV/storage)64 A Max. fuse/circuit rating (output)90 A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)80A of distributed generation / 95A with IQ Gateway breaker included Production metering CT 200 A solid core pre-installed and wired to IQ Gateway Consumption monitoring CT (CT-200-SPLIT)A pair of 200 A split core current transformers MECHANICAL DATA Dimensions (WxHxD)37.5 x 49.5 x 16.8 cm (14.75” x 19.5” x 6.63”). Height is 21.06" (53.5 cm) with mounting brackets. Weight 7.5 kg (16.5 lbs) Ambient temperature range -40º C to +46º C (-40º to 115º F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors • 60 A breaker branch input: 4 to 1/0 AWG copper conductors • Main lug combined output: 10 to 2/0 AWG copper conductors • Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing. Altitude To 2000 meters (6,560 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 Enphase IQ Combiner 4/4C 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Product data sheet Characteristics DU221RB SWITCH NOT FUSIBLE GD 240V 30A 2P NEMA3R Stock Code: Stock - Normally stocked in distribution facility Price*: 177.00 USD Main Product Single Throw Safety Switch Current Rating 30 A Certifications UL listed Enclosure Rating NEMA 3R Disconnect Type Non-fusible disconnect Factory Installed Neutral None Mounting Type Surface Number of Poles 2 Electrical Connection Lugs Duty Rating General duty Ordering and shipping details Category 00106 - D & DU SW,NEMA3R, 30-200A Discount Schedule DE1A GTIN 00785901490340 Nbr. of units in pkg.1 Package weight(Lbs)4.8600000000000003 Returnability Y Country of origin MX Contractual warranty Period 18 months Product Life Status : Commercialised Th e i n f o r m a t i o n p r o v i d e d i n t h i s d o c u m e n t a t i o n c o n t a i n s g e n e r a l d e s c r i p t i o n s a n d / o r t e c h n i c a l c h a r a c t e r i s t i c s o f t h e p e r f o r m a n c e o f t h e p r o d u c t s c o n t a i n e d h e r e i n . Th i s d o c u m e n t a t i o n i s n o t i n t e n d e d a s a s u b s t i t u t e f o r a n d i s n o t t o b e u s e d f o r d e t e r m i n i n g s u i t a b i l i t y o r r e l i a b i l i t y o f t h e s e p r o d u c t s f o r s p e c i f i c u s e r a p p l i c a t i o n s . It i s t h e d u t y o f a n y s u c h u s e r o r i n t e g r a t o r t o p e r f o r m t h e a p p r o p r i a t e a n d c o m p l e t e r i s k a n a l y s i s , e v a l u a t i o n a n d t e s t i n g o f t h e p r o d u c t s w i t h r e s p e c t t o t h e r e l e v a n t s p e c i f i c a p p l i c a t i o n o r u s e t h e r e o f . Ne i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n . Ne i t h e r S c h n e i d e r E l e c t r i c I n d u s t r i e s S A S n o r a n y o f i t s a f f i l i a t e s o r s u b s i d i a r i e s s h a l l b e r e s p o n s i b l e o r l i a b l e f o r m i s u s e o f t h e i n f o r m a t i o n c o n t a i n e d h e r e i n . * P r i c e s a r e i n d i c a t i v e Feb 1, 2018 1 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Flush Mount System Strength Tested All components evaluated for superior structural performance. PE Certified Pre-stamped engineering letters available in most states. Class A Fire Rating Certified to maintain the fire resistance rating of the existing roof. Design Assistant Online software makes it simple to create, share, and price projects. UL 2703 Listed System Entire system and components meet newest effective UL 2703 standard. 25-Year Warranty Products guaranteed to be free of impairing defects. Built for solar’s toughest roofs. IronRidge builds the strongest mounting system for pitched roofs in solar. Every component has been tested to the limit and proven in extreme environments. Our rigorous approach has led to unique structural features, such as curved rails and reinforced flashings, and is also why our products are fully certified, code compliant and backed by a 25-year warranty. Datasheet © 2019 IronRidge, Inc. All rights reserved. U.S. Patents: #8,695,290; #9,819,303; #9,865,938; Others Pending. Version 1.70 XR Rails Attachments Datasheet Design Assistant Go from rough layout to fully engineered system. For free. Go to IronRidge.com/design Resources XR100 Rail The ultimate residential solar mounting rail. • 8’ spanning capability • Heavy load capability • Clear and black finish Bonded Splices All rails use internal splices for seamless connections. • Self-drilling screws • Varying versions for rails • Forms secure bonding XR10 Rail A low-profile mounting rail for regions with light snow. • 6’ spanning capability • Moderate load capability • Clear and black finish XR1000 Rail A heavyweight mounting rail for commercial projects. • 12’ spanning capability • Extreme load capability • Clear anodized finish FlashFoot2 Flash and mount XR Rails with superior waterproofing. • Twist-on Cap eases install • Wind-driven rain tested • Mill and black finish Drop-in design for rapid rail attachment. • Secure rail connections • Slot for vertical adjusting • Clear and black finish Slotted L-Feet Clamps & Grounding UFOs Universal Fastening Objects bond modules to rails. • Fully assembled & lubed • Single, universal size • Clear and black finish Stopper Sleeves Snap onto the UFO to turn into a bonded end clamp. • Bonds modules to rails • Sized to match modules • Clear and black finish CAMO Bond modules to rails while staying completely hidden. • Universal end-cam clamp • Tool-less installation • Fully assembled NABCEP Certified Training Earn free continuing education credits, while learning more about our systems. Go to IronRidge.com/training Bond and attach XR Rails to roof attachments. • T & Square Bolt options • Nut uses 7/16” socket • Assembled and lubricated Bonding Hardware CONTINUING EDUCATION REGISTERED PROVIDER Flash and mount conduit, strut, or junction boxes. • Twist-on Cap eases install • Wind-driven rain tested • Secures ¾” or 1” conduit Conduit Mount Grounding Lugs Connect arrays to equipment ground. • Low profile • Single tool installation • Mounts in any direction 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 © 2021 IronR idge, Inc. CA Flush Mount System Certification Letter - 1 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com Attn: Corey Geiger, COO, IronRidge Inc. Date: July 1st, 2021 Re: Structural Certification and Span Tables for the IronRidge Flush Mount System This letter addresses the structural performance and code compliance of IronRidges Flush Mount System. The contents of the letter shall be read in its entirety before applying to any project design. The Flush Mount System is a proprietary rooftop mounting system used to support photovoltaic (PV) modules installed in portrait or landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof attachment with 3/8 stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core components are shown in Exhibit EX-0015. The IronRidge Flush Mount System is designed and certified to the structural requirements of the reference standards listed below, for the load conditions and configurations tabulated in the attached span tables. ASCE/SEI 7-16 Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) 2018 International Building Code (IBC-2018) 2019 California Building Code (CBC-2019) 2015 Aluminum Design Manual (ADM-2015) Report SEAOC (Structural Engineer Association of California) PV2-2017 Wind Design for Solar Arrays The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed, covering wind exposure categories B, C, & D, roof zones provided in ASCE 7-16 for gable & hip roof profiles, and roof slopes of 8° to 45°. The tabulated spans are applicable when the following conditions are met: 1. Span is the distance between two adjacent roof attachment points (measured at the center of the attachment fastener). 2. Each module shall be supported by 2 rails (2 rail system) or 3 rails (3 rail system). Spans are calculated based on 2 rail systems, and conservatively deemed acceptable for 3 rail systems. 3. The underlying roof slope, measured between the roof surface and horizontal plane, is 8º to 45º. 4. The mean roof height, defined as the average of the roof eave height and the roof ridge height measured from grade, does not exceed 30 feet. 5. A clearance from the underside of the array to the roof surface of 2 minimum shall be provided and the height of the array, the distance from the module top surface to the roof surface (defined as h 2 ), shall not exceed 10. 6. Module length and area shall not exceed the maximum values listed on the respective span tables. 7. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidges Flush Mount Installation Manual and other applicable standards for the general roof construction practice. © 2021 IronRidge, Inc. CA Flush Mount System Certification Letter - 4 28357 Industrial Blvd. Hayward, CA 94545 1-800-227-9523 IronRidge.com The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no consideration of the structural adequacy of the chosen roof attachments, PV modules, or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. Sincerely, Gang Xuan, SE Senior Structural Engineer 2021.07.14 17:00:22 -07'00' 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 2 RATINGS Product markings are located on the Grounding Lug bolt head. MARKINGS UL 2703 LISTeD Conforms to STD UL 2703 Standard for Safety First edition: Mounting Systems, Mounting Devices, Clamping/ Retention Devices, and Ground Lugs for Us e with Flat-Plat e Photovoltaic Modules and Panels • Max Overcurrent Protective Device (OCPD) Rating: 40A • Max Module Size: 30.5 ft² • Module Orientation: Portrait or Landscape • System Design Load Rating: 10 PSF downward, 5 PSF upward, 5 PSF lateral • Actual system structural capacity including spans and cantilevers are defined by PE stamped certification letters. • CAMO Specific Design Load rating: 50 PSF downward, 50 PSF upward, 15 PSF lateral Certified to CSA TIL No. A-40 Photovoltaic Module Racking Systems • Load Rating: 2400 PA [50 PSF] CLASS A SYSTeM FIRe RATING PeR UL 2703 • Any Roof Slope with Module Types 1, 2, 3, 13, 19, 25 & 29. • Any module-to-roof gap is permitted, with no perimeter guarding required. This rating is applicable with any third-party attachment. • Class A rated PV systems can be installed on Class A, B, and C roofs without affecting the roof fire rating. WATeR SeAL RATINGS: • UL 441 (Flashfoot2, All Tile Hook, Knockout Tile, Flashvue, L-Mount) • TAS 100(A)-95 (Flashfoot2, All Tile Hook, Knockout Tile, Flashvue, L-Mount, Qbase) • Tested and evaluated without sealant. • Any roofing manufacturer approved sealant is allowed. Ratings applicable for roof slopes between 2:12 and 12:12 STRUCTURAL CeRTIFICATION • Designed and Certified for Compliance with the International Building Code & ASCE/SEI-7 FLORIDA PRODUCT APPROVAL #FL29843 • Conforms to TAS202, TAS100(A) • Approved for installation both inside and outside High Velocity Hurricane Zones (HVHZ) • Allowable design pressure up to +100/-100 PSF • Additional details and full list of approved components can be found Here. #5003807 8431 Murphy Drive Middleton, WI 53562 USA Telephone: 608.836.4400 Facsimile: 608.831.9279 www.intertek.com Test Verification of Conformity This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. GFT-OP-11a (24-MAR-2014) Signature: Name: Nalini Mandadi Position: Project Engineer Date: 11/14/2014 In the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the requirements of the referenced specifications at the time the tests were carried out. Applicant Name & Address: IronRidge, Inc. 28357 Industrial Blvd Hayward, CA 94545 USA Product Description: Flush Mount System with XR Rails. Ratings & Principle Characteristics: Fire Class Resistance Rating: -Flush Mount (Symmetrical). Class A Fire Rated for Low Slope applications when using Type 1, 2, 3, 13, 19, 25 and 29 listed photovoltaic modules. Class A Fire Rated for Steep Slope applications with Type1, 2 and 3, listed photovoltaic modules. Tested with a 5” gap (distance between the bottom the module frame and the roof covering), per the standard this system can be installed at any gap allowed by the manufacturers installation instructions. No perimeter guarding is required. This rating is applicable with any IronRidge or 3’rd party roof anchor. Models: IronRidge Flush Mount with XR Rails Brand Name:IronRidge Flush Mount Relevant Standards : UL 2703 (Section 15.2 and 15.3) Standard for Safety Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels, First Edition dated Jan. 28, 2015 Referencing UL1703 Third Edition dated Nov. 18, 2014, (Section 31.2) Standard for Safety for Flat-Plate Photovoltaic Modules and Panels. Verification Issuing Office: Intertek Testing Services NA, Inc. 8431 Murphy Drive Middleton, WI 53562 Date of Tes ts: 08/27/2014 to 03/17/2015 Test Report Number(s): 101769343MID-001r1, 101769343MID-001a, 101915978MID-001 & 101999492MID-001ar1-cr1, 104428358MID-001 EEV Revision Summary 8/27/2020 Added type 13, 19, 25 and 29 to system, update address. This verification is part of the full test report(s) and should be read in conjunction with them. This report does not automatically imply product certification. Completed by: Chris Zimbrich Reviewed by: Chad Naggs Title: Technician I, Fire Resistance Title: Technical Team Lead, Fire Resistance Signature: Signature: Date: 08/27/2020 Date: 08/27/2020 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 21 MODULe COMPATIBILITY MAKe MODeLS 7KH)OXVK0RXQW6\VWHPPD\EHXVHGWRJURXQGDQGRUPRXQWD39PRGXOHFRPSO\LQJZLWK8/RQO\ZKHQWKHVSHFL¿FPRGXOHKDV EHHQHYDOXDWHGIRUJURXQGLQJDQGRUPRXQWLQJLQFRPSOLDQFHZLWKWKHLQFOXGHGLQVWUXFWLRQV8QOHVVRWKHUZLVHQRWHG³[[[´UHIHUVWRWKH PRGXOHSRZHUUDWLQJDQGERWKEODFNDQGVLOYHUIUDPHVDUHLQFOXGHGLQWKHFHUWL¿FDWLRQ FRAMeD MODULe LIST Adani Adani modules with 35 and 40mm frames $6;<==[[[ :KHUH;FDQEH%0RU3<FDQEHRUDQG==FDQEHEODQN3(5&%3(5&RU$%3(5& Aionrise Aionrise modules with 35 and 40mm frames $,21\\*[[[ :KHUH\\FDQEHRU Amerisolar Amerisolar modules with 35, 40 and 50 mm frames $6E<[[[= :KHUHEFDQEHRU<FDQEH03030RU3DQG=FDQEHEODQN:RU:% Aptos Solar Aptos modules with 35 and 40 mm frames DNA-yy-zzaa-xxx :KHUH\\FDQEHRU]]FDQEH0)RU%)DQGDDFDQEHRU Astronergy Solar Astronergy modules with 30, 35, 40, and 45 mm frames DD60EE\\&]][[[ :KHUH³DD´FDQEH&+RU$EEFDQEHRU³\\´FDQEHEODQNRU&FDQ030%/ 0+&0%/+&3+&0'*RU0'*7DQG³]]´FDQEHEODQN+9)%RU)%+ ASUN ASUN modules with 35 and 40 mm frames $681[[[<<==DD :KHUH<<FDQEHRU==FDQEH0RU0+DQGDDFDQEHEODQNRU%% Auxin Auxin modules with 40 mm frames AXN6y6zAxxxB :KHUH\FDQEH0RU3]FDQEHRUDQG$FDQEH)0RU7DQG%FDQEHEODQN$ B or C Axitec Axitec Modules with 30, 35 and 40 mm frames $&[[[<DD==E :KHUH<FDQEH030%RU0+DDFDQEHEODQNRU==FDQEHRU EFDQEH6;99%;9RU0; Boviet Boviet modules with 35 and 40mm frames %90==DD<<[[[%FF :KHUH==FDQEHRUDDFDQEHRU<<LV0RU3DQG%FDQEHEODQN/RU6DQGFF FDQEHEODQN++%)+%)'*++&++&%)++&%)'*+&%)RU+&%)'* BYD BYD modules with 35 mm frames %<'[[[$<== :KHUH$FDQEH030+RU3+<FDQEH&RU.DQG==FDQEHRU Canadian Solar Canadian Solar modules with 30, 32, 35 and 40 mm frames &6E<[[[= :KHUHEFDQEHRU<FDQEH+./1389:;RU<DQG=FDQEH03063;06' P-AG, P-SD, MB-AG, PB-AG, MS-AG, or MS-SD CertainTeed CertainTeed modules with 35 and 40 frames &7[[[<==$$ :KHUH<FDQEH03RU+&==FDQEHRUDQG$$FDQEHRU CSUN Csun modules with 35 and 40 mm frames YYxxx-zzAbb :KHUH<<LV&681RU667]]LVEODQNRUDQG$LVEODQN30RU00EELVEODQN%%%% BW, or ROOF Dehui Dehui modules with 30, 35 and 40mm frames '+0<<<=[[[ :KHUH³<<<´FDQEHDQG³=´FDQEH%)RU: © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 22 MODULe COMPATIBILITY Ecosolargy Ecosolargy modules with 35, 40, and 50 mm frames ECOxxxYzzA-bbD :KHUH³<´FDQEH$+6RU7³]]´FDQEHRU³$´FDQEH0RU3³EE´FDQEHRUDQG³'´FDQ be blank or B ET Solar ET Solar modules with 30, 35, 40, and 50 mm frames (7<===[[[$$ :KHUH<FDQEH3/RU0===FDQEH%+%+%+%+%+DQG$$FDQ EH*/7%7::%::%%:%*::*:%$&:%&2::&2::%&2RU%%$& Flex Flex modules with 35, 40, and 50 mm frames );6[[[<<== :KHUH³<<´FDQEH%%RU%&DQG³==´FDQEH0$$%0$$:0$%:6$$%6$$:6$&% 6$&:6$':6%$%6%$:6%&%RU6%&: *&/ *&/PRGXOHVZLWKPPDQGPPIUDPHV *&/DE<<[[[ :KHUH³D´FDQEH0RU3³E´FDQEHRUDQG³<<´FDQEH+RU'+ GigaWatt Solar Gigawatt modules with 40 mm frames GWxxxYY :KHUH³<<´FDQEHHLWKHU3%RU0% +DQVRO +DQVROPRGXOHVZLWKDQGIUDPHV +6[[[<<]] :KHUH³<<´FDQEH3%3'3(7%7'8%8'RU8(DQG³]]´FDQEH$+$1$1$1+++9 RU-+ +DQZD6RODU +DQZKD6RODUPRGXOHVZLWKDQGPPIUDPHV +6/DD3<<[[[= :KHUH³DD´FDQEHHLWKHURU³<<´FDQEH3$RU3%DQG³=´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or X +\XQGDL +\XQGDLPRGXOHVZLWKDQGPPIUDPHV +L<6[[[== :KHUH<FDQEH$'RU66FDQEH0RU6DQG==FDQEH*,+*+,.,0,0)0*3,5,5* 5*%)5*%.6*7,RU7* Itek Itek Modules with 40 and 50 mm frames IT-xxx-YY :KHUH³<<´FDQEHEODQN+(RU6(RU6( 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 23 MODULe COMPATIBILITY JA Solar JA Solar modules with 30, 35, 40 and 45 mm frames -$\\]]EEZZ[[[DD :KHUH³\\´FDQEH030RU3³]]´FDQEHEODQN./59%.)$7*)$5/%./ 7*5%.57*9%.%.7*RU/%.7*³EE´FDQEHRUZZFDQEH ''''6666666666RU6DQG³DD´FDQEH%30% 056,6&35%%%%%%5(%% Jinko Jinko modules with 35 and 40 mm frames -.0<[[[==DD :KHUH<FDQHLWKHUEHEODQNRU6==FDQEH03RU33DQGDDFDQEHEODQN%+/ %/+/+%+%/+%/(3-%-%(33OXV90;5/5/% 7/%5/95/79%-%-3OXV9+9/9+/9+/9+/ 790;+%'93+/79RU+/90; .\RFHUD .\RFHUD0RGXOHVZLWKPPIUDPHV .<[[[==$$ :KHUH³<´FDQEH'RU8³==´FDQEHEODQN*;RU6;DQG³$$´FDQEH/38/)8838/36/3%/)% /)%6/)%/3%$&%&)&$&%&)&8&$&%&)&8&%&)&%&0&$RU 6MPA /* /*PRGXOHVZLWKDQGPPIUDPHV /*[[[<D=EE :KHUH<FDQEH$(0146DFDQEH$RU=FDQEH&.7RU:DQGEEFDQEH$$ $%%(($:**-./199 /RQJL /RQJLPRGXOHVZLWKDQGPPIUDPHV /5D<<==[[[0 :KHUHDFDQEHRU<<FDQEHEODQNRUDQG==FDQEHEODQN%.%3+93%3( 3++%'+,%+,++3%+3+RU+,%' Mission Solar Mission Solar modules with 33, 35 and 40 mm frames <<<EE[[[==DD :KHUH<<<FDQEH06(RU7;6EEFDQEHEODQNRU$==FDQEHEODQN006(626465 6;76RUDQGDDFDQEHEODQN%%%:--6.57-6:=.7RU6 Mitsubishi Mitsubishi modules with 46 mm frames 390<<[[[== :KHUH³<<´FDQEH/(RU-(DQG³==´FDQEHHLWKHU+'+'RU)% Moltech IM and XS series modules with 40, 45, and 50 mm frames Next Energy Alliance Next Energy Alliance modules with 35 and 40mm frames \\1($[[[== ZKHUH³\\´FDQEHEODQNRU86³==´FDQEH00%RU0 Neo Solar Power Neo Solar Power modules with 35 mm frames '<[[[==DD :KHUH³<´FDQEH0RU3³==´FDQEH%$%$($($+$+$DQG³DD´FDQEHEODQN7)0(RU ME (TF) 3DQDVRQLF+,7 Panasonic modules with 35 and 40 mm frames 9%+1[[[<<]]$ :KHUH³<<´FDQEHHLWKHU.$5$6$RU=$³]]´FDQEHHLWKHU%%% %RUDQG³$´FDQEHEODQN(*RU1 Panasonic (EverVolt) Panasonic modules with 30 mm frames EVPVxxxA :KHUH$FDQEHEODQNRU+.RU3. Peimar Peimar modules with 40 mm frames SbxxxYzz :KHUH³E´FDQEH*0RU3³<´FDQEH0RU3DQG³]]´FDQEHEODQN%)RU)% Philadelphia Solar Philadelphia modules with 35 and 40 mm frames PS-YzzAA-xxx :KHUH<FDQEH0RU3]]FDQEHRUDQG$$FDQEHEODQN%)+&RU+&%) Phono Solar Phono Solar modules with 35, 40, and 45 mm frames 36[[[<==$ :KHUH<FDQEH000+0+00+RU3==FDQEHRUDQG$FDQEH)788+RU7+ © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 24 MODULe COMPATIBILITY Recom Recom modules with 35 and 40 mm frames RCM-xxx-6yy :KHUH³\\´FDQEH0$0%0(RU0) REC Solar REC modules with 30, 38 and 45 mm frames 5(&[[[<<== :KHUH³<<´FDQEH$$013133(3(73737307360736730RU73DQG³==´FDQ EHEODQN%ODFN%/.%/.6/9RU3XUH Renesola ReneSola modules with 35, 40 and 50 mm frames $$[[[<== :KHUH$$FDQEH6306/3RU-&<FDQEHEODQN)0RU6DQG==FDQEHEODQN$E$EE$EK $EKE$EY$EYE%E%EE%EK%EKE%EY%EYE'E'EERU%E Renogy Renogy Modules with 40 and 50 mm frames RNG-xxxY :KHUH³[[[´LVWKHPRGXOHSRZHUUDWLQJDQG³<´FDQEH'RU3 Risen Risen Modules with 30, 35 and 40 mm frames 560\\D[[[== :KHUH\\FDQEHRUDFDQEHRUDQG==FDQEH03RU%0'* S-Energy S-Energy modules with 35 and 40mm frames 6$%%&&<<<[[[= :KHUH³$´FDQEH&'/RU1³%%´FDQEHEODQNRU³&&´FDQEHEODQNRU³<<<´FDQ EHEODQN%'(0$(0$,0%(0%,0&(RU0&,DQG³=´FDQEH903RU3 SEG Solar SEG Solar with 30, 35 and 40 mm frames 6(*D<<[[[== :KHUHDFDQEHEODQNRU%<<FDQEHEODQN0$0%3$RU3%DQG==FDQEHEODQN%%%*%: +9:%::%0%%0$+9%0$%*%0$7%%0%7%%0%+9%0'+9%0%%* Seraphim USA Seraphim modules with 30, 35, 40 and 50 mm frames 653[[[<<<== :KHUH[[[LVWKHPRGXOHSRZHUUDWLQJDQG<<<FDQEH%0$%0'0$0%3$3%4$;;;; DQG4%;;;;==LVEODQN%%%*RU+9 Sharp Sharp modules with 35 and 40 mm frames NUYYxxx :KHUH³<<´FDQEH6$ RU6& Silfab Silfab Modules with 35 and 38 mm frames 6<<=[[[$E :KHUH<<FDQEH,/6$/$6*RU/*=FDQEHEODQN03RU;$FDQEHEODQN%+01DQGE FDQEH$&*./178RU; Solaria Solaria modules with 35 and 40 mm frames 3RZHU;7[[[<== :KHUH<FDQEH5RU&DQG==FDQEH$&%'%;%<3'3/3030$&3;3=:;RU:= Solarcity (Tesla) Solarcity modules with 40 mm frames SCxxxYY :KHUH³<<´FDQEHEODQN%RU% SolarTech SolarTech modules with 40 and 42 mm frames AAA-xxxYY :KHUH$$$FDQEH3(5&%%3(5&%:+-7%%+-7%:RU678<<FDQEHEODQN3(5&RU+-7 SolarWorld AG 6RODU:RUOG6XQPRGXOH3OXV3URWHFW%LVXQ;/%LVXQ;/PD\EHIROORZHGE\PRQRSRO\GXREODFNENRU FOHDUPRGXOHVZLWKRUPPIUDPHV SW-xxx 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 MODULe COMPATIBILITY © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 25 SolarWorld Americas 6RODU:RUOG6XQPRGXOH3OXV3URWHFW%LVXQ;/%LVXQ;/PD\EHIROORZHGE\PRQRSRO\GXREODFNENRU clear; modules with 33 mm frames SWA-xxx Sonali Sonali Modules with 40 mm frames SSxxx Stion 6WLRQ7KLQ¿OPPRGXOHVZLWKPPIUDPHV STO-xxx or STO-xxxA SunEdison 6XQ(GLVRQ0RGXOHVZLWK PPIUDPHV 6(<[[[=$%&'( :KHUH<FDQEH%)+35RU==FDQEHRU$FDQEH%&'(+,-./0RU1%FDQEH%RU :&FDQEH$RU&'FDQEHRUDQG(FDQEHRU Suniva Suniva modules with 35, 38, 40, 46, and 50 mm frames 237[[[$$%<<<= 09;[[[$$%<<<= :KHUH$$LVHLWKHURU%LVHLWKHURU<<<LVHLWKHU%RU%DQG=LVEODQN or B Sunpower Sunpower standard (G3 or G4) or InvisiMount (G5) 35, 40 and 46 mm frames 635=E[[[<< :KHUH=LVHLWKHU$(30RU;³E´FDQEHEODQNRUDQG³<<´FDQEHEODQN%/. &20&$&'$&($&%/.($&*$&%/.&$&RU%/.'$& Sunspark Sunspark modules with 40 mm frames 6<<[[[=$ :KHUH³<<´FDQEH0;RU67DQG³=´FDQEH00%00%3RU:DQG$FDQEHRU Suntech Suntech Modules with 35, 40 and 50mm frames 673[[[\]]DD :KHUH\LVEODQNRU6DQG]]FDQEH$RU$8DQGDDFDQEH9G9HP9IZ9IK:GE:GH Wd, or Wfhb Talesun Talesun modules with 30, 35 and 40mm frames 7$%\==DD[[[E :KHUH$FDQEH'RU3%FDQEHRU \FDQEHEODQN)*+,RU/==FDQEHRU DDFDQEH00+RU3DQGEFDQEHEODQN%7RU+ Tesla Tesla modules with 40 mm frames TxxxY :KHUH<FDQEH+RU6 Trina Trina Modules with 30, 35, 40 and 46mm frames 760[[[<<== :KHUH<<FDQEH'''''''('('(9'(*'(*9&'(0'(*0& '('('(*&'(;3$3&3'3'3$3&3'3(RU3(DQG ==FDQEHEODQN,,,,''666,,$$ $$$,,$,,$,,$,,$,,$,,$,,++,,+,,+,,+&,, +&,,00,,0,,0&,, URE URE modules with 35 mm frames '\=[[[DD :KHUH'FDQEH'RU)\FDQEH$RU=FDQEH.RU0DQGDDFDQEH+$+$+$(*%% E8G or E8G-BB Vikram Vikram solar modules with 40 mm frames 96\\==$$$EE :KHUH\\FDQEH030%%0+060+%%RU3%%==FDQEHRU$$$LVWKHPRGXOHSRZHU UDWLQJDQGEEFDQEHRU VSUN VSUN modules with 30, 35 and 40 mm frames VSUNxxx-YYz-aa :KHUH<<FDQEHRU]FDQEH030+3+RU%0+DQGDDFDQEHEODQN%% BW, or DG MODULe COMPATIBILITY © 2022 IRONRIDGE, INC. VERSION 3.4 FLUSH MOUNT INSTALLATION MANUAL - 26 MAKe MODeLS FRAMeLeSS MODULe LIST Astronergy Solar Astronergy frameless modules &+603'*[[[ Canadian Solar Canadian Solar frameless modules &6E<[[[= :KHUH³E´FDQEHRU³<´LV.38RU;DQG³=´FDQEH0)*06)*3)*0%)*RU3%)* +HOLHQH +HOLHQHIUDPHOHVVPRGXOHV <<==[[[$ :KHUH<<FDQEH==FDQEH0DQG$FDQEH*+ Jinko Jinko frameless modules -.0[[[33'9 Prism Solar Prism Solar frameless modules %=<<[[[$$$ :KHUH=FDQEHLRU1<<FDQEH6RU6DQG$$$FDQEHEODQNRU%67& Risen Risen frameless modules 560\\[[[== :KHUH³\\´FDQEHRUDQG³==´FDQEH0'*RU3'* Stion Stion frameless modules 67/[[[RU67/[[[$ Sunpreme Sunpreme frameless modules GXB-xxxYY :KHUH³<<´FDQEHEODQNRU6/ Trina Trina frameless modules TSM-xxxYY :KHUH³<<´FDQEHHLWKHU'(*,,'(*,,'(*,,'(*,,'(*,,'(*&,, '(*&,,'(*,,3(*3(*3(*3(*3(*RU3(* Waaree Waaree modules with 40mm frames WSyy-xxx ZKHUH³\\´FDQEHEODQN0RU0% Winaico Winaico modules with 35 and 40 mm frames :V\[[[=D :KHUH\FDQEHHLWKHU3RU7=FDQEHHLWKHU03RU0;DQGDFDQEHEODQNRU Yingli Yingli modules with 35 and 40 mm frames </[[[=\\ :KHUH=FDQEH'RU3\\FDQEHEEGEERUG =16KLQH =16KLQHPRGXOHVZLWKPPIUDPHV =;0<$$$[[[0 :KHUH<FDQEHRU$$$FDQEH1+1+1+'%1+/''6+6+'%RU 6+/'' 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Tech Brief Moving Flashing Forward We set out to design a flashing that checked all the boxes: fully waterproof, fast and easy to install correctly, economical, and strong enough to handle every environmental condition. FlashVue does it all. The optimized flashing design features a large viewport, for easy alignment with the pilot hole. And the GripCap and GripCap+ sit snugly in place, so the lag can be driven single-handedly. FlashVue™ GripCap & GripCap+ The 360º capable GripCap (2.74” tall) and GripCap+ (3.74” tall) can be placed in any orientation, and provide a “friction-fit” for easy installs. Push snug into the viewport, without worrying it will roll away or rotate while driving the lag. Three-Tier Water Seal, Reimagined FlashVue’s seal architecture utilizes three layers of protection. The viewport is elevated 0.30”, and provides a “friction-fit” for the GripCap. The GripCap fully covers the viewport while a sealing washer adds another layer of protection. And an EPDM washer and lag bolt “seal the deal” in the stack. Large Viewport in Flashing The large viewport makes it easy to align the flashing with the pilot hole, and drive the lag centered into the rafter. The elevated rim not only provides a sturdy dock for the GripCap or GripCap+, but increases water-shedding capabilities. ⌀ 0.75” Triple Certified to Protect the Roof™ UL 2703, 441 (27) TAS 100(A)-95 © 2020 IronRidge, Inc. All rights reserved. Visit www.ironridge.com or call 1-800-227-9523 for more information. Version 1.0 Tech Brief Solve Roof Undulations See Your Pilot Holes Also Available: GripCap+ We know roofs are not always perfectly flat. GripCap+ can help when undulations get in the way. Large Viewport in Flashing FlashVue makes pilot holes highly visible, like never before. No more tedious guesswork on hot roofs. Trusted Strength & Certification Attachment Loading FlashVue has been tested and rated to support 1161 (lbs) of uplift and 353 (lbs) of lateral load. Structural Certification Designed and certified for compliance with the International Building Code & ASCE/SEI-7. Water Seal Ratings Passed both the UL 441 Section 27 “Rain Test” and TAS 100-95 “Wind Driven Rain Test” by Intertek. UL 2703 Listed System Conforms to UL 2703 mechanical and bonding requirements. See Flush Mount Manual for more info. 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Conductor, Conduit, and OCPD Sizing Validation 1. Maximum System DC Voltage Test 1.1. Enphase inverter w/6 Ureco FAM440E8G-BB (440W)s Array Properties Array Type Microinverter Array System Description Enphase inverter w/6 Ureco FAM440E8G-BB (440W)s Module FAM440E8G-BB (440W) Highest number of modules in series in a PV Source Circuit 1 Design Low Temp.3.3°C Module voc 49.6V Temp. Coefficient voc -0.134V/C CEC Code Calculations A. Maximum Voltage of PV Source Circuit 52.51V see 690.7(A) CEC 690.7(A) requires that if the PV module manufacturer provides a temperature coefficient of open-circuit voltage, it must be used to calculate the PV array's maximum system voltage. It includes an information note recommending the use of the ASHRAE 'Extreme Annual Mean Minimum Design Dry Bulb Temperature' as the design low temperature. Using these values, the module Voc (49.6V) will increase to 52.51V at the design low temperature ( 3.3°C). (3.3°C - 25°C) X -0.134V/C + 49.6V = 52.51V The module Voc at the design low temperature is 52.51V. 52.51V X 1 = 52.51V CEC Code Validation Tests 1. PV Source Circuit maximum Voc must not exceed 600V 52.51V < 600V = true PASS 2. Wire, Conduit, and OCPD Code Compliance Validation 2.1. #1: AC Branch Output: Transition Box to AC Disconnect Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 10A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 52°C Power Source Description Branch of 6 IQ8PLUS-72-2-US microinverters Power Source Current 7.26A Voltage 240V CEC Code Calculations A. Continuous Current 7.26A see Article 100 Equipment maximum rated output current is 6 X 1.21A = 7.26A B. Ampacity of Conductor 30A see Table 310.15(B)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 23A see Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100 The temperature factor for 90°C insulation at 52°C is 0.76. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.76) and by the fill factor (1). 30A X 0.76 X 1 = 22.8A rounded to 23A D. Max Current for Terminal Temp. Rating 25A see 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 25A. E. Minimum Allowed OCPD Rating 9A see 240.4 CEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 7.26A X 1.25 = 9.07A rounded down to 9A F. Maximum Allowed OCPD Rating 20A see 240.4(D) CEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 10A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") CEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (240.4) 10 >= 7.26A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (240.4) 23A >= 10A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (240.4) 10 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (Article 100) 23A >= 7.26A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (215.2(A)(1)) 30A > 7.26A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (110.14(C)) 25A >= 7.26A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (Table 250.122) 12 AWG >= 14 AWG = true PASS 8. Conduit must meet code recommendation for minimum size (300.17) 0.5in. >= 0.5in. = true PASS 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 2.2. #2: AC Disconnect Output: AC Disconnect to AC Combiner Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 10A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 32°C Power Source Description Branch of 6 IQ8PLUS-72-2-US microinverters Power Source Current 7.26A Voltage 240V CEC Code Calculations A. Continuous Current 7.26A see Article 100 Equipment maximum rated output current is 6 X 1.21A = 7.26A B. Ampacity of Conductor 30A see Table 310.15(B)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100 The temperature factor for 90°C insulation at 32°C is 0.96. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 25A see 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 25A. E. Minimum Allowed OCPD Rating 9A see 240.4 CEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 7.26A X 1.25 = 9.07A rounded down to 9A F. Maximum Allowed OCPD Rating 20A see 240.4(D) CEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 10A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") CEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (240.4) 10 >= 7.26A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (240.4) 29A >= 10A (OCPD Rating) = true PASS 3. OCPD rating must not exceed max OCPD rating for conductor (240.4) 10 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (Article 100) 29A >= 7.26A = true PASS 5. Conductor Ampacity must be at least 125% of Continuous Current (215.2(A)(1)) 30A > 7.26A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (110.14(C)) 25A >= 7.26A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (Table 250.122) 12 AWG >= 14 AWG = true PASS 8. Conduit must meet code recommendation for minimum size (300.17) 0.5in. >= 0.5in. = true PASS 2.3. #3: AC Combiner Output: AC Combiner to Utility Disconnect Circuit Section Properties Conductor 12 AWG THWN-2, Copper Equipment Ground Conductor (EGC) 12 AWG THWN-2, Copper OCPD(s) 10A Raceway/Cable 0.5" dia. EMT Lowest Terminal Temperature Rating 75°C Maximum Wire Temperature 32°C Power Source Description Enphase inverter w/6 Ureco FAM440E8G-BB (440W)s Power Source Current 7.26A Voltage 240V CEC Code Calculations A. Continuous Current 7.26A see Article 100 Equipment maximum rated output current is 7.26A B. Ampacity of Conductor 30A see Table 310.15(B)(16) Ampacity (30°C) for a copper conductor with 90°C insulation in conduit/cable is 30A. C. Derated Ampacity of Conductor 29A see Table 310.15(B)(3)(c), Table 310.15(B)(3)(a), and Article 100 The temperature factor for 90°C insulation at 32°C is 0.96. The fill factor for a conduit/cable that has 2 wires is 1. The ampacity derated for Conditions of Use is the product of the conductor ampacity (30A) multiplied by the temperature factor (0.96) and by the fill factor (1). 30A X 0.96 X 1 = 28.8A rounded to 29A D. Max Current for Terminal Temp. Rating 25A see 110.14(C) The lowest temperature rating for this conductor at any termination is 75°C. Using the method specified in 110.14(C), the maximum current permitted to ensure that the device terminal temperature does not exceed its 75°C rating would be the amount referenced in the 75°C column in Table 310.15(B)(16), which is 25A. E. Minimum Allowed OCPD Rating 9A see 240.4 CEC 690.9(B) requires that the OCPD be rated for no less than 1.25 times the Continuous Current of the circuit. 7.26A X 1.25 = 9.07A rounded down to 9A F. Maximum Allowed OCPD Rating 20A see 240.4(D) CEC 240.4(D) requires that OCPD rating not exceed 20A when protecting a Copper 12 AWG conductor. G. Minimum Required EGC Size 14 AWG see Table 250.122 The smallest EGC size allowed is 14 AWG for OCPD rating 10A according to Table 250.122. H. Minimum Recommended Conduit Size 0.5" dia. see 300.17 The total area of all conductors is 0.0765in². With a maximum fill rate of 0.4, the recommended conduit diameter is 0.5. Qty Description Size Type Area Total Area 2 Conductor 12 AWG THWN-2 0.0133in² 0.0266in² 1 Neutral 8 AWG THWN-2 0.0366in² 0.0366in² 1 Equipment Ground 12 AWG THWN-2 0.0133in² 0.0133in² 4 0.0765in² 0.0765in² / 0.4 = 0.1913in² (Corresponding to a diameter of 0.5") CEC Code Validation Tests 1.OCPD rating must be at least 125% of Continuous Current (240.4) 10 >= 7.26A X 1.25 = true PASS 2.Derated ampacity must exceed OCPD rating, or rating of next smaller OCPD (240.4) 29A >= 10A (OCPD Rating) = true PASS 3.OCPD rating must not exceed max OCPD rating for conductor (240.4) 10 (OCPD Rating) <= 20A = true PASS 4.Derated Ampacity must be greater than or equal to the Continuous Current (Article 100) 29A >= 7.26A = true PASS 5.Conductor Ampacity must be at least 125% of Continuous Current (215.2(A)(1)) 30A > 7.26A x 1.25 = true PASS 6.Max current for terminal must be at least 125% of the Continuous Current. (110.14(C)) 25A >= 7.26A X 1.25 = true PASS 7.EGC must meet code requirements for minimum size (Table 250.122) 12 AWG >= 14 AWG = true PASS 8. Conduit must meet code recommendation for minimum size (300.17) 0.5in. >= 0.5in. = true PASS 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 STRUCTURAL DESIGN PARAMETERS ELEVATION 66 FT SEISMIC 1.062 SDS WIND (ASCE 7-16)95 MPH, EXPOSURE CATEGORY B, RISK CATEGORY II GROUND SNOW LOAD 0 PSF ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 4/12 (18.4°) MEAN ROOF HEIGHT 13.9FT ROOF DECKING 15/32" OSB CONSTRUCTION RAFTERS (2X10'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL URECO FAM440E8G-BB DIMENSIONS (AREA) 83.0IN X 41.3IN X 1.4IN (23.8 SQ FT) WEIGHT 53.8LB MOUNTING SYSTEM PROPERTIES RAIL MODEL IRONRIDGE XR10 ANCHOR MODEL IRONRIDGE FV-01-B1 (FLASHED), 3.38IN AIR GAP FASTENING METHOD 2.5 INCH EMBEDMENT INTO RAFTERS WITH (1) 5/16IN DIA. FASTENER GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 6 53.8 322.8 MICROINVERTERS 6 1.1 6.5 LINEAR FEET OF RAIL 86 FT 0.4 37.5 ANCHORS 24 0.6 14.4 MISC. HARDWARE 5.4 5.4 TOTAL ARRAY WEIGHT 386.6 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 6 23.8 142.8 POINT LOAD (386.6 LBS / 24 ATTACHMENTS) 16.1 LBS DIST. LOAD (386.6 LBS / 142.8 SQFT)2.71 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. CONTRACTOR MAY NEED TO MAKE MINOR ADJUSTMENTS TO ANCHOR LOCATIONS. IN NO CASE SHALL THE ANCHOR SPACING EXCEED "MAX. ANCHOR SPACING" ANCHOR PLACEMENT PARAMETERS (ASCE 7-16) WIND PRESSURE ZONE MODULE WIND EXPOSURE MAX. ALLOWABLE RAIL SPAN MAX. ANCHOR SPACING MAX. ALLOWABLE CANTILEVER ZONES 1, 2E, 2N, 2R, 3E NORMAL 92.0IN 72.0IN 36.8IN ZONE 3R NORMAL 90.0IN 72.0IN 36.0IN DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION ("LHD") OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LHD OR 3 FT. THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE ROOF PLANES IN ACCORDANCE WITH GUIDANCE PROVIDED BY ASCE 7-16 FIGURES 30.3-2B–I. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LHD), 0.04 * LHD, 3 FT) 3.0 ft = max(min(0.4 * 13.9 ft, 0.1 * 23.6 ft), 0.04 * 23.6 ft, 3 ft) P-525014 GR I D - T I E D S O L A R P O W E R S Y S T E M NG U Y E N R E S I D E N C E 46 0 9 W E L D O N P L SA N T A A N A , C A 9 2 7 0 4 ATTACHMENT PLAN DOC ID:ED8F10-3 DATE:5/13/22 CREATOR:B.H. REVIEWER: REVISIONS PV-5 4609 W El Don Pl - 10111143409/21/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 4609 W EL DON PL. SANTA ANA, CA 92704 PREMIER BUILDERS & HARDSCAPE INC B #995068 Bryan Ha, Premier Builders (714) 653-8019 ocpremierbuilders@gmail.com 6/21/2022 4609 W El Don Pl - 10111143409/21/22 CITY OF SANTA ANA SOLAR PERMIT APPLICATION WORKSHEET PLEASE PRINT REV: 8/29/19 PROJECT ADDRESS: SUITE: SAPIN # USE OF BUILDING: RESIDENTIAL COMMERCIAL INDUSTRIAL OTHER MASTER ID# NATURE OF WORK: SOLAR P.V. SYSTEM SOLAR WATER HEATING/COLLECTOR SYSTEM OTHER JOB DESCRIPTIO N : ________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________ ________________________________________________________________________________________________________________ BUILDING OWNERS NAME:PHONE NO: ADDRESS:CITY: STATE:ZIP: TENANTS NAME (Comm/Ind):PHONE NO: CONTRACTORS NAME:STATE CONTR. #:LICENSE CLASS: PHONE NO: ADDRESS: CITY: STATE:ZIP: WORKERS COMP. POLICY#: EXP. DATE:INSURANCE COMPANY: SANTA ANA BUS. LIC. #: ARCHITECT/ENGINEER: STATE LICENSE #: PHONE NO: ADDRESS:CITY: STATE:ZIP: CONTACT NAME: PHONE NO: E-MAIL ADDRESS: BLDG. FEE $ OCC. GROUP:P/C FEE PD $ VALUATION: $ SUBMITTAL DATE:____________________TYPE OF CONSTR: FLOOD ZONE:___________________PROCESSED________________________ PLANNING OK TO CHECK & DATE:__________________________ BLDG. DEPT. APPROVAL & DATE:___________________________ PLNG CONDITIONS: _________________________________________________________________________________________________ NUMBER OF PANELS:___________________ SYSTEM kWA:_________________________6 NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM WITH NO BATTERY STORAGE, 2.64 KW with 6 modules and micro inverters 2.64 NEENA NGUYEN Santa Ana CA 92704 PREMIER BUILDERS 995068 B 7146538019 8832 LA GRAND AVE Garden Grove CA 92841 9214301 07/13/2023 State Fund 369662 Bryan Ha 7146538019 ocpremierbuilders@gmail.com 8000 4609 1/2 W EL DON PL SANTA ANA, CA 92704 4609 1/2 W EL DON PL 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 CITY OF SANTA ANA DEVELOPMENT FEES WORKSHEET -- ELECTRICAL PERMIT APP FOR ELECTRICAL 06-30-2020 APP-02 CEC2019 Project Address: Contractor: Tenant Name: Address: Building Owner: City: St.: Zip: Address: Contractor License No.: City: St.: Zip: Contractor Email: Phone:Phone: Contact Person: Contact E-Mail Strongly Recommended PLEASE PRINT: Contact Phone: NEW BUILDING OCCUPANCY CHANGE ELECTRICAL ITEM Count $ EACH ELECTRICAL ITEM Count $ EACH 125 Volt Receptacle Outlets 1.57 LOW VOLTAGE SYSTEMS – EACH: phone, data outlet, speaker, thermostat, door holder, doorbell, pull station, smoke detector, alarm device, card reader, etc. (circle items)Light Switches, Occupancy Sensors 1.70 Light Fixtures 1.13 COMMERCIAL: Air Conditioners, Heat Pumps 104.40 FIRST 10 devices or outlets 36.50 Factory-Wired Units (Solid Hook-Ups) 26.71 Additional devices, each 3.45 Dedicated Circuits (15 or 20 AMP Receptacles) 26.71 Each control panel, power supply annunciator, switch or aux equip.17.39Time Clock, Photo-Cell, Time Switch 13.03 Track-Light, Cable Tray, Special Raceway, Plugmold, Under-Floor Duct, Plug-In Busway, Surface Duct, Etc. (Each 100 Feet or any fraction thereof) 26.71 RESIDENTIAL: Single Dwelling unit 39.56 Each add’l dwelling unit (2 to 20) 34.80 Each add’l unit (over 20) 21.24 SERVICE METERS & PANELS: Service Meter, Reset Meter, Subpanel, Switchboard, Motor Control Center, Transfer Switch, Busduct, or other Distribution Equipment changes or modifications. (circle items as needed) MISCELLANEOUS Light Standard (Pole) with 1 Fixture 26.72 Additional Fixtures – same pole 0.00 Power Pole (Temporary) 111.04 Use this column if a Service All others here Additional distribution poles 26.72 Under 400 amperes 57.40 Swimming Pool, Spa, Fountain 130.46 400 amperes to 1199 amperes 156.51 Above ground spa 56.37 1200 amperes and over 260.79 Demolition 52.21 POWER APPARATUS: Motor, Transformer, Welder, Industrial Equipment, Oven, Rectifier, Generator, Surge Arrestor, Water Heater, Photovoltaic Panel, or other Power Equipment changes or modifications. (circle items as needed) Per HP, kW, or kVA SIGNS & neon/LED decorative lighting ($200 refundable sign bond) 80.95 NEW or TOTAL REWIRE for SINGLE FAMILY DWELLINGS SFD Per square foot .16 0 to 1 3.84 Garage Per square foot .16 Over 1 to 10 25.09 SUBTOTAL $ Over 10 to 50 49.78 P/C 65% of SUBTOTAL $ Over 50 to 100 113.06 MIN. FEE – (Nonresidential) $ 79.06 Over 100 to 500 162.45 ISSUANCE & General Plan Surcharge $ 59.30 + 23.79 = $8 3.09 Over 500 202.92 TOTAL $ OFFICE USE ONLY BLDG PMT RECEIPT BY DATE OCCUPANCY TYPE P/CPAID Nguyen Residence PREMIER BUILDERS Neena Nguyen Neena Nguyen Santa Ana CA 92704 8832 LA GRAND AVE Garden Grove CA 92841 B #995068 ocpremierbuilders@gmail.com 714-653-8019 ocpremierbuilders@gmail.com Bryan Ha 714-653-8019 4609 1/2 W EL DON PL 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 4609 W El Don Pl - 10111143409/21/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan NGUYEN RESIDENCE 4609 W EL DON PL SANTA ANA, CA 92704 System AC Size: 2.64KW Premier Builders 8832 LA GRAND AVE GARDEN GROVE CA 92841 4609 W El Don Pl - 10111143409/21/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram FAM440E8G-BB URECO 83.0IN X 41.3IN X 1.4IN (23.8 SQ FT) IQ8PLUS-72-2-US ENPHASE 6 ENPHASE IQ COMBINER 4C OR EQUIV. GENERIC GEN-AWB-TB-1-4X OR EQUIV. SQUARE D DU221RB OR EQUIV.DU221RB ENPHASE IQ8PLUS-72-2-US SQUARE D DU221RB OR EQUIV. IQ8PLUS-72-2-US 225 200 240 10 2.64KW Nguyen Residence 4609 W EL DON PL 7146538019 Premier Builders 8832 LA GRAND AVE GARDEN GROVE CA 92841 4609 W El Don Pl - 10111143409/21/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____ oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNSSEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARDLINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) URECO FAM440E8G-BB 10.74 41.00 49.60 11.34 90 440 41.00 -0.1339x ENPHASE IQ8PLUS-72-2-US 60 290 240 1.2 10 240 30 7.26 240 10 240 Nguyen Residence 4609 W EL DON PL 2.64kw 2 32 Premier Builders 8832 LA GRAND AVE GARDEN GROVE CA 92841 4609 W El Don Pl - 10111143409/21/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 4609 1/2 W EL DON PL. SANTA ANA, CA 92704 PREMIER BUILDERS & HARDSCAPE INC B #995068 Bryan Ha, Premier Builders (714) 653-8019 ocpremierbuilders@gmail.com 10/3/2022 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan NGUYEN RESIDENCE System AC Size: 2.64KW 4609 1/2 W El Don Pl Santa Ana, CA Premier Builders 8832 LA GRAND AVE GARDEN GROVE CA 92841 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram FAM440E8G-BB URECO 83.0IN X 41.3IN X 1.4IN (23.8 SQ FT) IQ8PLUS-72-2-US ENPHASE 6 ENPHASE IQ COMBINER 4C OR EQUIV. GENERIC GEN-AWB-TB-1-4X OR EQUIV. SQUARE D DU221RB OR EQUIV.DU221RB ENPHASE IQ8PLUS-72-2-US SQUARE D DU221RB OR EQUIV. IQ8PLUS-72-2-US 225200 240 10 Nguyen Residence 7146538019 System AC Size: 2.64KW 4609 1/2 W El Don Pl Santa Ana, CA Premier Builders 8832 LA GRAND AVE GARDEN GROVE CA 92841 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____ oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNSSEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARDLINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) URECO FAM440E8G-BB 10.74 41.00 49.60 11.34 90 440 41.00 -0.1339x ENPHASE IQ8PLUS-72-2-US 60 290 240 1.2 10 240 30 7.26 240 10 240 Nguyen Residence 2 32 System AC Size: 2.64KW 4609 1/2 W El Don Pl Santa Ana, CA Premier Builders 8832 LA GRAND AVE GARDEN GROVE CA 92841 4609 W El Don Pl - 101111434 & Rev 10111225111/23/22