HomeMy WebLinkAbout513 S Everglade Ave - Plan09/26/2022
Design Criteria
Code 2019 California Building Code (ASCE 7-16)
Risk category II Wind Load (component and Cladding)
Roof Dead Load Dr 10 psf V 95 mph
PV Dead Load DPV 3 psf Exposure C
Roof Live Load Lr 20 psf
Ground Snow S 0 psf
If you have any questions on the above, please do not hesitate to call.
Sincerely,
Eugene Munyanziza, P.E.
EV Engineering, LLC
projects@evengineersnet.com
http://www.evengineersnet.com
Exp: 06/30/2024
RE: Structural Certification for Installation of Residential Solar
CECILIA TORRES:513 S EVERGLADE ST, SANTA ANA, CA 92704
Attn: To Whom It May Concern
This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of
the PV system to existing roof framing. From the field observation report, the roof is made of Composition
shingle roofing over roof plywood supported by 2X4 Rafters at 24 inches. The slope of the roof was
approximated to be 20 degrees and the allowable maximum rafter span is 6 feet between supports.
After review of the field observation data and based on our structural capacity calculation, the existing roof
framing has been determined to be adequate to support the imposed loads without structural upgrades.
Contractor shall verify that existing framing is consistent with the described above before install. Should
they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install.
Capacity calculations were done in accordance with applicable building codes.
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
Structural Letter for PV Installation
Date: 09/26/2022
Job Address: 513 S EVERGLADE ST
SANTA ANA, CA 92704
Job Name: CECILIA TORRES
Job Number: 220926CT
Scope of Work
Table of Content
Sheet
1 Cover
2 Attachment Uplift checks
3 Roof Framing Check
4 Seismic Check and Scope of work
Engineering Calculations Summary
Code 2019 California Building Code (ASCE 7-16)
Risk category II
Roof Dead Load Dr 10 psf
PV Dead Load DPV 3 psf
Roof Live Load Lr 20 psf
Ground Snow S 0 psf
Wind Load (component and Cladding)
V 95 mph
Exposure C
References
NDS for Wood Construction
Sincerely,
Eugene Munyanziza, P.E.
EV Engineering, LLC
projects@evengineersnet.com
http://www.evengineersnet.com Exp: 06/30/2024
This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of
the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per
manufacturer's approved installation specifications.
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
Wind Load Cont.
95 mph ASCE 7-16 Figure 26.5-1B
C
1.0 ASCE 7-16 Sec 26.8.2
0.85 ASCE 7-16 Table 26.10-1
0.85 ASCE 7-16 Table 26.6-1
1.00 ASCE 7-16 Table 26.9-1
16.65 psf
20.0 Degrees
1.5 Conservatively assuming all exposed
0.8 conservatively assuming 10 ft2 effective area
Uplift (W)Zone(1) Zone(2r) Zone(2e)Zone(3)
Fig. 30-3-2 GCp=-2.1 -2.6 -2.7 -2.7
Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-41.95 -51.94 -53.93 -53.93
GCp=0.3 Figure 30.3-2
P=qh(GCp)(γE)(γa)=4.49 Equation 29.4-7
Rafter Attachments: 0.6D+0.6W (CD=1.6)
Connection Check
Attachment max. spacing= 6 ft
5/16"X4.75"Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A - NDS
2.5 in DFL Assumed
Prying Coefficient 1.4
Allowable Capacity= 760 lbs
Zone Trib Width Area (ft) Uplift (lbs) Down (lbs)
Zone(1) 6 16.5 333.7 123.7
Zone(2r) 6 16.5 407.9 123.7
Zone(2e) 6 16.5 422.7 123.7
Zone(3) 6 16.5 422.7 123.7
Conservative Max= 422.7 < 760
CONNECTION IS OK
Risk Category =
KZ =
Kd =
Ke =
2.Embedment is measured from the top of the framing member to the tapered tip of a lag screw.
Embedment in sheading or other material does not count.
II
V=
Exposure =
1.Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift
governs
γE=
γa=
KZt =
qh= 0.00256KzKztKdKeV2 =
Pitch =
Lag Screw Penetration
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
Vertical Load Resisting System Design
Roof Framing Rafters
Snow Load Fully Exposed
pg= 0 psf Ct = 1.1
Ce = 0.9 Is = 1.0
pf = 0 psf
pfmin. = 0.0 psf
ps = 0 psf Conservatively (Cs=1) 0 plf
Max Length, L = 6.0 ft (Rafter maximum Allowable Horizontal Span)
Tributary Width, WT = 24 in
Dr = 10 psf 20 plf
PvDL = 3 psf 18 plf
Load Case: DL+0.75(0.6W+S)
0.75(Pnet+Ps)+ Ppvcos(θ)+PDL= 42 plf
Mdown= 189 lb-ft
Mallowable = Sx x Fb' (wind)= 456 lb-ft > 189 lb-ft OK
Load Case: DL+S
Ps+ Ppvcos(θ)+PDL= 38 plf
Mdown= 171 lb-ft
Mallowable = Sx x Fb' (wind)= 456 lb-ft > 171 lb-ft OK
Load Case: DL+0.6W
Pnet+ Ppvcos(θ)+PDL= 43.4 plf
Max Moment, Mu= 195 lb-ft
Mallowable = Sx x Fb' (wind)= 634 lb-ft > 195 lb-ft OK
Pv max Shear= 123.7 lbs
Shear, Vu=wL/2+Pv Point Load = 238 lbs
Max Shear, Vu=wL/2+Pv Point Load = 238 lb
Member Capacity
DF-L No.2
2X4 CL CF Ci Cr KF φ λ
Fb = 900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi
Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi
E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi
Emin = 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi
Depth, d = 3.5 in
Width, b = 1.5 in
Cross-Sectonal Area, A = 5.25 in2
Moment of Inertia, Ixx = 5.35938 in4
Section Modulus, Sxx = 3.0625 in3
Allowable Moment, Mall = Fb'Sxx = 396.2 lb-ft DCR=Mu/Mall = 0.42 < 1 Satisfactory
Allowable Shear, Vall = 2/3Fv'A = 630.0 lb DCR=Vu/Vall = 0.38 < 1 Satisfactory
Design Value Adjusted Value
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
Siesmic Loads Check
Roof Dead Load 10 psf
% or Roof with Pv 33%
Dpv and Racking 3 psf
Average Total Dead Load 10.4 psf
Increase in Dead Load 3.6% OK
The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and
therefore no further seismic analysis is required.
Limits of Scope of Work and Liability
We have based our structural capacity determination on information in pictures and a drawing set titled PV
plans -CECILIA TORRES. The analysis was according to applicable building codes, professional engineering and
design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for
the proposed solar panel installation referenced in the stamped plan set and were made according to generally
recognized structural analysis standards and procedures.
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
SPEC SHEET
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
RAIL SPEC SHEET
SS-05
513 S Everglade
Ave12/20/22
A
A
A
A
A
A
A
A
MOUNTING DETAIL
S-01SCALE:1"=10'-0"
NOTE:PENETRATIONS ARE STAGGERED
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
INSTALLATION NOTES
1. STRUCTURAL ROOF MEMBER LOCATIONS ARE
ESTIMATED AND SHOULD BE LOCATED AND
VERIFIED BY THE CONTRACTOR WHEN LAG BOLT
PENETRATION OR MECHANICAL ATTACHMENT TO
THE STRUCTURE IS REQUIRED.
2. ROOFTOP PENETRATIONS FOR SOLAR RACKING
WILL BE COMPLETED AND SEALED WITH APPROVED
SEALANT PER CODE BY A LICENSED CONTRACTOR.
3. LAGS MUST HAVE A MINIMUM 2.5" THREAD
EMBEDMENT INTO THE STRUCTURAL MEMBER.
4. ALL PV RACKING ATTACHMENTS SHALL BE
STAGGERED BY ROW BETWEEN THE ROOF FRAMING
MEMBERS AS NECESSARY.
5. ROOF MOUNTED STANDARD RAIL REQUIRES ONE
THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL
GREATER THAN 40'.
6. ALL CONDUCTORS AND CONDUITS ON THE ROOF
SHALL BE MINIMUM 7/8" ABOVE THE ROOF
SURFACE (INCLUDING CABLES UNDERNEATH
MODULES AND RACKING).
7. THE PV INSTALLATION SHALL NOT OBSTRUCT ANY
PLUMBING, MECHANICAL OR BUILDING ROOF
VENTS.
ROOF ACCESS PATHWAYS AND SETBACKS:
1204.2.1 SOLAR PHOTOVOLTAIC SYSTEMS FOR GROUP
R-3 BUILDINGS.SOLAR PHOTOVOLTAIC SYSTEMS FOR
GROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS
1204.2.1.1 THROUGH 1204.2.1.3.
EXCEPTIONS:
1. THESE REQUIREMENTS SHALL NOT APPLY TO
STRUCTURES DESIGNED AND CONSTRUCTED IN
ACCORDANCE WITH THE CALIFORNIA RESIDENTIAL
CODE.
2. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS
WITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITS
HORIZONTAL OR LESS.
1204.2.1.1 PATHWAYS TO RIDGE. NOT FEWER THAN
TWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATE
ROOF PLANES,FROM LOWEST ROOF EDGE TO RIDGE,
SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER
THAN ONE PATHWAY SHALL BE PROVIDED ON THE
STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH
ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT FEWER
THAN ONE 36-INCH-WIDE (914 MM) PATHWAY FROM
LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON
THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY,
ON AN ADJACENT ROOF PLANE OR STRADDLING THE
SAME AND ADJACENT ROOF PLANES
1204.2.1.2 SETBACKS AT RIDGE.FOR PHOTOVOLTAIC
ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN
VIEW TOTAL ROOF AREA,
A SETBACK OF NOT LESS THAN 18 INCHES (457
MM)WIDE IS REQUIRED ON BOTH SIDES OF A
HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS
OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW
TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36
INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES
OF A HORIZONTAL RIDGE.
1204.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS.
PANELS AND MODULES INSTALLED ON GROUP R-3
BUILDINGS SHALL NOT BE PLACED ON THE PORTION OF
A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND
RESCUE OPENING. A PATHWAY OF NOT LESS THAN 36
INCHES (914 MM) WIDE SHALL BE PROVIDED TO THE
EMERGENCY ESCAPE AND RESCUE OPENING
1204.2.1.3 ALTERNATIVE SETBACKS AT RIDGE.
WHERE AN AUTOMATIC SPRINKLER SYSTEM IS
INSTALLED WITHIN THE DWELLING IN ACCORDANCE
WITH SECTION 903.3.1.3, SETBACKS AT THE RIDGE
SHALL CONFORM TO ONE OF THE FOLLOWING:
1. FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT
OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A
SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE
IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE.
2.FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN
66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A
SETBACK OF NOT LESS THAN 36 INCHES (914 MM) WIDE
IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE
ALUMINIUM RAILS
2 X 4 RAFTERS@
2'-0"SPACING
ARRAY MP-01
STRING CONFIGURATION
BRANCH DETAILS
A 8 MODULES
SITE INFORMATION - WIND SPEED: 95 MPH AND SNOW LOAD: 0 PSF
SR.
NO AZIMUTH PITCH NO. OF
MODULES
ARRAY AREA
(SQ. FT.)ROOF TYPE ATTACHMENT ROOF
EXPOSURE FRAME TYPE FRAME
SIZE
FRAME
SPACING
MAX RAIL
SPAN
OVER
HANG
MP-01 90° 20° 8 169.1 COMPOSITION
SHINGLE
IRONRIDGE
FLASHFOOT2 ATTIC RAFTERS 2 X 4 2'-0" 6'-0" 2'-0"
AERIAL VIEW
6'
3'
1'-6"
Structural
Only
513 S Everglade
Ave12/20/22
MODULE
END CLAMPMID CLAMPMODULE
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
STRUCTURAL DETAIL
S-02
MID-CLAMP AND END-CLAMP ANATOMY
GROUNDING LUG
MID CLAMP
ASSEMBLY
MODULE
FRAME
RAIL
MODULE TO MODULE & MODULE TO RAIL
GROUNDING MID-CLAMP
SCALE: NTS
GROUNDING DETAILS
IRONRIDGE RAIL
IRONRIDGE INTERNAL SPLICE
SELF-DRILLING SCREW
SCALE: NTS
RAIL TO RAIL
T-BOLT
DEAD LOAD CALCULATIONS
BOM QUANTITY LBS/UNIT TOTAL WEIGHT
(LBS)
MODULES 8 48.50 388.00
MID-CLAMP 6 0.170 1.02
END-CLAMP 20 0.300 6.00
RAIL LENGTH 60 0.790 47.40
SPLICE BAR 0 0.650 0.00
IRONRIDGE
FLASHFOOT2 22 1.88 41.36
MICRO-INVERTER 8 2.38 19.04
TOTAL WEIGHT OF THE SYSTEM (LBS)483.78
TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)169.06
WEIGHT PER SQ. FT.(LBS)2.86
WEIGHT PER PENETRATION (LBS)16.13
MODULES DATA
HANWHA Q CELL QPEAK DUO BLK ML-G10
400W
MODULE DIMS 73.97"x41.14"x1.25"
LAG SCREWS 5/16"x4.75":2.5"MIN
EMBEDMENT
2 X 4 RAFTERS
@2'-0" SPACING
COMPOSITION SHINGLE ROOF
MODULE
5/16" X 4.75" LAG SCREW
1 BOLT PER PENETRATION
LOAD BEARING WALL SCALE:NTS
ROOF FRAMING DETAILS
ATTACHMENT DETAIL- IRONRIDGE FLASHFOOT2
FLASHFOOT2SOLAR MODULE
STAINLESS STEEL 5/16" X 4.75" LAG SCREW 2.5"
EMBEDMENT PILOT HOLE REQUIRED
RAIL
FLASHING
6" MAX
Structural
Only
513 S Everglade
Ave12/20/22
(8)HANWHA Q CELL QPEAK DUO BLK ML-G10 400W ,MODULES WITH
(8)ENPAHSE IQ8PLUS-72-2-US(240V)(SI-1)
(1) BRANCH OF (8) MICRO-INVERTERS
(N)JUNCTION
BOX
2 1
ENPHASE Q CABLE
DC CONDUCTORS
AC CONDUCTORS
3
(N)125A END FED
MAIN PANEL
UTILITY
GRID
(N
)
1
0
0
A
M
A
I
N
BR
E
A
K
E
R
PV BREAKER AT THE
OPPOSITE END OF
BUSBAR
20A 2P
PV BREAKER
EXISTING 120/240V 1PH 60HZ
METER#:SCE
222012-789643M
N
G
(E) GROUND
ELECTRODE
LOADS
3
(N)30A AC
DISCONNECT
AC DISCONNECT
NON FUSED 30A,
120/240V, 2P
15A
AC COMBINER BOX
X-IQ-AM1-240-4 120/240
NEMA 3R INSTALL
(1)20A PV 2P BREAKERS
(ONLY FOR SOLAR, NO
LOADS TO BE ADDED)
ENPHASE IQ
COMBINER 4
20A
MODULE SPECIFICATION
MODEL
HANWHA Q CELL
QPEAK DUO BLK
ML-G10 400W
MODULE POWER @ STC 400W
OPEN CIRCUIT VOLTAGE:Voc 45.30V
MAX POWER VOLTAGE:Vmp 37.13V
SHORT CIRCUIT CURRENT:Isc 11.14A
MAX POWER CURRENT:Imp 10.77A
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
SINGLE LINE DIAGRAM
E-01
1. CONDUCTORS EXPOSED TO SUNLIGHT
SHALL BE LISTED AS SUNLIGHT
RESISTANT PER CEC 310.10(D).
2. CONDUCTORS EXPOSED TO WET
LOCATIONS SHALL BE SUITABLE FOR
USE IN WET LOCATIONS PER CEC
310.10(C).
3. MAXIMUM DC/AC VOLTAGE DROP SHALL
BE NO MORE THAN 2%.
4. ALL CONDUCTORS SHALL BE IN
CONDUIT UNLESS OTHERWISE NOTED.
5. BREAKER/FUSE SIZES CONFORMS TO
CEC 240.6 CODE SECTION.
6. AC GROUNDING ELECTRODE
CONDUCTOR SIZED PER CEC 250.66.
7. AMBIENT TEMPERATURE CORRECTION
FACTOR IS BASED ON CEC 690.31(A).
8. AMBIENT TEMPERATURE ADJUSTMENT
FACTOR IS BASED ON CEC 310.15(B)(2).
9. MAX. SYSTEM VOLTAGE CORRECTION IS
PER CEC 690.7.
10. CONDUCTORS ARE SIZED PER WIRE
AMPACITY TABLE CEC 310.15(B)(16).
ELECTRICAL NOTESSINGLE LINE DIAGRAM: DC SYSTEM SIZE - 3200W, AC SYSTEM SIZE - 2320W, CEC AC RATING:2883W
AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >>
· REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF
INVERTERS = MAX CURRENT PER 690.8(A)(3) X 125% = MAX CURRENT PER
690.8(B)(1)
· CORRECTED AMPACITY CALCULATIONS: AMPACITY X TEMPERATURE DERATE
FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY PER
690.8(B)(2)
· DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(A)(3)
<DERATED CONDUCTOR AMPACITY
AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C
TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK
1 1.21 X 8 = 9.68 X 1.25 = 12.10A 30 X 0.87 X 1 =26.10A 12.10A <26.10A
2 1.21 X 8 = 9.68 X 1.25 = 12.10A 40 X 0.87 X 1 =34.80A 12.10A <34.80A
3 1.21 X 8 = 9.68 X 1.25 = 12.10A 40 X 0.87 X 1 =34.80A 12.10A <34.80A
CONDUIT SCHEDULE
TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND
1 NONE (2) 10AWG PV WIRE NONE (1) 6AWG BARE COPPER
2 3/4"EMT (2) 10AWG THHN/THWN-2 NONE (1) 8AWG THHN/THWN-2
3 3/4"EMT (2) 10AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 (1) 8AWG THHN/THWN-2
NOTE:
MAIN PANEL RATING:125A, MAIN BREAKER RATING:100A
120% RULE: (125AX1.2)-100A=50A =>ALLOWABLE BACKFEED IS 50A
OCPD CALCULATIONS:
INVERTER OVERCURRENT PROTECTION=
INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS
=1.21x1.25x8=12.10 A =>PV BREAKER = 20A
ALLOWABLE BACKFEED 50A =>20A PV BREAKER
THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS.
ELECTRICAL CALCULATION
MICRO INVERTER SPECIFICATIONS
MODEL
ENPAHSE
IQ8PLUS-72-2-US(240V)(SI-
1)
POWER RATING 290W
MAX OUTPUT CURRENT 1.21A
CEC WEIGHTED EFFICIENCY 97%
MAX NO OF MICRO
INVERTERS/BRANCH 13
MAX DC VOLTAGE 60V
NOTE:
1. EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT.
2. MAIN PANEL UPGRADE:REPLACE EXISTING MAIN SERVICE PANEL WITH NEW
125/100A MAIN PANEL.
3. NEW SERVICE PANEL MUST BE COMBINATION/ALL-IN-ONE, AND METER AND MAIN
CANNOT BE SEPARATE.
4. 125A SERVICE REQUIRES A MINIMUM 6 AWG CONDUCTOR TO 10' OF UNDERGROUND
METAL WATER PIPE ELECTRODE. BOND ON THE INSIDE/OUTSIDE WITHIN FIRST 5' OF
WHERE THE WATER ENTERS THE BUILDING. AN ADDITIONAL CONNECTION UFER OR 2
NEW RODS IS NEEDED - LOCATED 6' FROM OTHER ELECTRODES. WATER PIPE MAY NOT
BE USED TO BOND ANY ELECTRODES UNLESS BURIED OR ENCASED, ELECTRODE
CONNECTIONS MUST BE ACCESSIBLE.
5. LISTED COMBINATION OVERHEAD AND UNDERGROUND FEED SERVICE BOXES
REQUIRED.
513 S Everglade
Ave12/20/22
MSPACCB
WARNING PLACARD
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
WARNING PLACARDS -1
PL-01
POWER TO THIS BUILDING IS ALSO
SUPPLIED FROM THE FOLLOWING
SOURCES WITH DISCONNECTS LOCATED
AS SHOWN
!
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THIS PHOTOVOLTAIC
SYSTEM ARE UNGROUNDED AND MAY BE
ENERGIZED
LABEL LOCATION
DC DISCONNECT,INVERTER
[To be used when inverter is
ungrounded]
WARNING!
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH LINE AND LOAD SIDES
MAY BE ENERGIZED IN THE OPEN POSITION
WARNING
LABEL LOCATION
AC DISCONNECT,
POINT OF INTERCONNECTION
PER CODE: CEC 690.13(B)
!
WARNING-ELECTRIC SHOCK HAZARD
NO USER SERVICEABLE PARTS INSIDE
CONTACT AUTHORIZED SERVICE
PROVIDE FOR ASSISTANCE
LABEL LOCATION
INVERTER, JUNCTION BOXES(ROOF),
AC DISCONNECT
WARNING:PHOTOVOLTAIC
POWER SOURCE
LABEL LOCATION
CONDUIT, COMBINER BOX
PER CODE: CEC690.31(G)(3)
LABEL LOCATION
AC DISCONNECT, POINT OF INTERCONNECTION
PER CODE: CEC 690.54
RATED AC OPERATING CURRENT
AC NOMINAL OPERATING VOLTAGE
9.68
240
AMPS AC
VAC
PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH
LABEL LOCATION
POINT OF INTERCONNECTION
PER CODE: CEC 705.12(B)(2)(3)(b)
WARNING
POWER SOURCE OUTPUT
CONNECTION
DO NOT RELOCATE THIS
OVER-CURRENT DEVICE
CAUTION: SOLAR CIRCUIT
LABEL LOCATION
MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR
DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE
ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND
ABOVE/BELOW PENETRATIONS AND ALL
COMBINER/JUNCTION BOXES.
PER CODE: CEC690.31(G)(3)
SOLAR DISCONNECT
LABEL LOCATION
DISCONNECT, POINT OF INTERCONNECTION
PER CODE: CEC690.31(B)
CAUTION: SOLAR ELECTRIC
SYSTEM CONNECTED
LABEL LOCATION
PLACED WITHIN THE MAIN SERVICE
DISCONNECT,
PLACED ON THE OUTSIDE OF THE COVER
WHEN DISCONNECT IS OPERATED WITH THE
SERVICE PANEL CLOSED.
PER CODE: CEC690.15 ,690.13(B)
TURN RAPID SHUTDOWN
SWITCH TO THE
"OFF" POSITION TO
SHUT DOWN PV SYSTEM
AND REDUCE
SHOCK HAZARD
IN THE ARRAY
SOLAR ELECTRIC
PV PANELS
SOLAR PV SYSTEM EQUIPPED
WITH RAPID SHUTDOWN
LABEL LOCATION
AC DISCONNECT, DC DISCONNECT,
POINT OF INTERCONNECTION
PER CODE: CEC690.56(C)(1)(a)
!!CAUTION:MULTIPLE SOURCES
OF POWER
NOTES:
ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE
RED WITH WHITE LETTERING U.O.N.
PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.
FASTENERS APPROVED BY THE LOCAL JURISDICTION
LABEL LOCATION
SERVICE PANEL
PER CODE: CEC 705.10
513 S EVERGLADE ST, SANTA ANA, CA 92704
SYSTEM UTILIZES MICRO-INVERTERS LOCATED UNDER EACH SOLAR MODULE
LABEL LOCATION
POINT OF INTERCONNECTION
PER CODE: CEC705.12(B)(3-4) AND 690.59
WARNING
DUAL POWER SOURCE SECOND
SOURCE IS PHOTOVOLTAIC
SYSTEM
!
RAPID SHUTDOWN
SWITCH FOR SOLAR PV
SYSTEM
LABEL LOCATION
INVERTER
PER CODE: CEC 690.56(C)(3)
SOLAR PHOTOVOLTAIC
ARRAYS ON ROOF
(E)UTILITY METER WITH
(N) MAIN SERVICE PANEL
(N) AC DISCONNECT
(N) ENPHASE COMBINER 4
513 S Everglade
Ave12/20/22
SPEC SHEET
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
MODULE SPEC SHEET
SS-01
513 S Everglade
Ave12/20/22
SPEC SHEET
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
INVERTER SPEC SHEET
SS-02
513 S Everglade
Ave12/20/22
SPEC SHEET
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
COMBINER SPEC SHEET
SS-03
513 S Everglade
Ave12/20/22
SPEC SHEET
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
MOUNT SPEC SHEET
SS-04
513 S Everglade
Ave12/20/22
09/26/2022
Design Criteria
Code 2019 California Building Code (ASCE 7-16)
Risk category II Wind Load (component and Cladding)
Roof Dead Load Dr 10 psf V 95 mph
PV Dead Load DPV 3 psf Exposure C
Roof Live Load Lr 20 psf
Ground Snow S 0 psf
If you have any questions on the above, please do not hesitate to call.
Sincerely,
Eugene Munyanziza, P.E.
EV Engineering, LLC
projects@evengineersnet.com
http://www.evengineersnet.com
Exp: 06/30/2024
RE: Structural Certification for Installation of Residential Solar
CECILIA TORRES:513 S EVERGLADE ST, SANTA ANA, CA 92704
Attn: To Whom It May Concern
This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of
the PV system to existing roof framing. From the field observation report, the roof is made of Composition
shingle roofing over roof plywood supported by 2X4 Rafters at 24 inches. The slope of the roof was
approximated to be 20 degrees and the allowable maximum rafter span is 6 feet between supports.
After review of the field observation data and based on our structural capacity calculation, the existing roof
framing has been determined to be adequate to support the imposed loads without structural upgrades.
Contractor shall verify that existing framing is consistent with the described above before install. Should
they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install.
Capacity calculations were done in accordance with applicable building codes.
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
Structural Letter for PV Installation
Date: 09/26/2022
Job Address: 513 S EVERGLADE ST
SANTA ANA, CA 92704
Job Name: CECILIA TORRES
Job Number: 220926CT
Scope of Work
Table of Content
Sheet
1 Cover
2 Attachment Uplift checks
3 Roof Framing Check
4 Seismic Check and Scope of work
Engineering Calculations Summary
Code 2019 California Building Code (ASCE 7-16)
Risk category II
Roof Dead Load Dr 10 psf
PV Dead Load DPV 3 psf
Roof Live Load Lr 20 psf
Ground Snow S 0 psf
Wind Load (component and Cladding)
V 95 mph
Exposure C
References
NDS for Wood Construction
Sincerely,
Eugene Munyanziza, P.E.
EV Engineering, LLC
projects@evengineersnet.com
http://www.evengineersnet.com Exp: 06/30/2024
This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of
the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per
manufacturer's approved installation specifications.
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
Wind Load Cont.
95 mph ASCE 7-16 Figure 26.5-1B
C
1.0 ASCE 7-16 Sec 26.8.2
0.85 ASCE 7-16 Table 26.10-1
0.85 ASCE 7-16 Table 26.6-1
1.00 ASCE 7-16 Table 26.9-1
16.65 psf
20.0 Degrees
1.5 Conservatively assuming all exposed
0.8 conservatively assuming 10 ft2 effective area
Uplift (W)Zone(1) Zone(2r) Zone(2e)Zone(3)
Fig. 30-3-2 GCp=-2.1 -2.6 -2.7 -2.7
Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-41.95 -51.94 -53.93 -53.93
GCp=0.3 Figure 30.3-2
P=qh(GCp)(γE)(γa)=4.49 Equation 29.4-7
Rafter Attachments: 0.6D+0.6W (CD=1.6)
Connection Check
Attachment max. spacing= 6 ft
5/16"X4.75"Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A - NDS
2.5 in DFL Assumed
Prying Coefficient 1.4
Allowable Capacity= 760 lbs
Zone Trib Width Area (ft) Uplift (lbs) Down (lbs)
Zone(1) 6 16.5 333.7 123.7
Zone(2r) 6 16.5 407.9 123.7
Zone(2e) 6 16.5 422.7 123.7
Zone(3) 6 16.5 422.7 123.7
Conservative Max= 422.7 < 760
CONNECTION IS OK
Risk Category =
KZ =
Kd =
Ke =
2.Embedment is measured from the top of the framing member to the tapered tip of a lag screw.
Embedment in sheading or other material does not count.
II
V=
Exposure =
1.Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift
governs
γE=
γa=
KZt =
qh= 0.00256KzKztKdKeV2 =
Pitch =
Lag Screw Penetration
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
Vertical Load Resisting System Design
Roof Framing Rafters
Snow Load Fully Exposed
pg= 0 psf Ct = 1.1
Ce = 0.9 Is = 1.0
pf = 0 psf
pfmin. = 0.0 psf
ps = 0 psf Conservatively (Cs=1) 0 plf
Max Length, L = 6.0 ft (Rafter maximum Allowable Horizontal Span)
Tributary Width, WT = 24 in
Dr = 10 psf 20 plf
PvDL = 3 psf 18 plf
Load Case: DL+0.75(0.6W+S)
0.75(Pnet+Ps)+ Ppvcos(θ)+PDL= 42 plf
Mdown= 189 lb-ft
Mallowable = Sx x Fb' (wind)= 456 lb-ft > 189 lb-ft OK
Load Case: DL+S
Ps+ Ppvcos(θ)+PDL= 38 plf
Mdown= 171 lb-ft
Mallowable = Sx x Fb' (wind)= 456 lb-ft > 171 lb-ft OK
Load Case: DL+0.6W
Pnet+ Ppvcos(θ)+PDL= 43.4 plf
Max Moment, Mu= 195 lb-ft
Mallowable = Sx x Fb' (wind)= 634 lb-ft > 195 lb-ft OK
Pv max Shear= 123.7 lbs
Shear, Vu=wL/2+Pv Point Load = 238 lbs
Max Shear, Vu=wL/2+Pv Point Load = 238 lb
Member Capacity
DF-L No.2
2X4 CL CF Ci Cr KF φ λ
Fb = 900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi
Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi
E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi
Emin = 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi
Depth, d = 3.5 in
Width, b = 1.5 in
Cross-Sectonal Area, A = 5.25 in2
Moment of Inertia, Ixx = 5.35938 in4
Section Modulus, Sxx = 3.0625 in3
Allowable Moment, Mall = Fb'Sxx = 396.2 lb-ft DCR=Mu/Mall = 0.42 < 1 Satisfactory
Allowable Shear, Vall = 2/3Fv'A = 630.0 lb DCR=Vu/Vall = 0.38 < 1 Satisfactory
Design Value Adjusted Value
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
Siesmic Loads Check
Roof Dead Load 10 psf
% or Roof with Pv 33%
Dpv and Racking 3 psf
Average Total Dead Load 10.4 psf
Increase in Dead Load 3.6% OK
The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and
therefore no further seismic analysis is required.
Limits of Scope of Work and Liability
We have based our structural capacity determination on information in pictures and a drawing set titled PV
plans -CECILIA TORRES. The analysis was according to applicable building codes, professional engineering and
design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for
the proposed solar panel installation referenced in the stamped plan set and were made according to generally
recognized structural analysis standards and procedures.
projects@evengineersnet.com
http://www.evengineersnet.com
513 S Everglade
Ave12/20/22
A
MS
P
AC
CB
A
A
A
A
A
A
A
VICINITY MAP
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:9/23/2022
SCALE:AS NOTED REV:A
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
APPLICABLE CODES
COVER PAGE
T-01
SCALE:1"=20'-0"
1.MODULES ARE LISTED UNDER UL 61730 AND
CONFORM TO THE STANDARDS.
2.INVERTERS ARE LISTED UNDER UL 1741 AND
CONFORM TO THE STANDARDS.
3.DRAWINGS ARE DIAGRAMMATIC, INDICATING
GENERAL ARRANGEMENT OF THE PV SYSTEM AND
THE ACTUAL SITE CONDITION MIGHT VARY.
4.WORKING CLEARANCES AROUND THE NEW PV
ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN
ACCORDANCE WITH CEC 110.26.
5.ALL GROUND WIRING CONNECTED TO THE MAIN
SERVICE GROUNDING IN MAIN SERVICE PANEL/
SERVICE EQUIPMENT.
6.ALL CONDUCTORS SHALL BE 600V, 75°C
STANDARD COPPER UNLESS OTHERWISE NOTED.
7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE
FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
8.THE SYSTEM WILL NOT BE INTERCONNECTED BY
THE CONTRACTOR UNTIL APPROVAL FROM THE
LOCAL JURISDICTION AND/OR THE UTILITY.
9.ROOF ACCESS POINT SHALL BE LOCATED IN
AREAS THAT DO NOT REQUIRE THE PLACEMENT
OF GROUND LADDERS OVER OPENINGS SUCH AS
WINDOWS OR DOORS, AND LOCATED AT STRONG
POINTS OF BUILDING CONSTRUCTION WHERE THE
ACCESS POINT DOES NOT CONFLICT WITH
OVERHEAD OBSTRUCTIONS SUCH AS TREES,
WIRES OR SIGNS.
10.PV ARRAY COMBINER/JUNCTION BOX
PROVIDES TRANSITION FROM ARRAY WIRING TO
CONDUIT WIRING
GENERAL NOTES
SHEET CATALOG
INDEX NO. DESCRIPTION
T-01 COVER PAGE
S-01 MOUNTING DETAIL
S-02 STRUCTURAL DETAIL
E-01 SINGLE LINE DIAGRAM
PL-01 WARNING PLACARDS
SS SPEC SHEET(S)
SITE PLAN LAYOUT
CECILIA TORRES - 3.200kW DC, 2.320kW AC, CEC AC RATING:2.883kW
ENGINEERING SCOPE OF WORK
1.ILLUMINE INDUSTRIES INC. HAS ONLY PROVIDED DRAFTING SERVICES FOR THE PERMIT DRAWINGS. NO ACTUAL ENGINEERING WORK, ENGINEERING REVIEW OR ENGINEERING
APPROVAL HAS BEEN CONDUCTED BY ILLUMINE INDUSTRIES INC UNLESS NOTED OTHERWISE.
2.WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT
DRAWINGS, HE/SHE:
a. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN
b.IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN
c.HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN
GENERAL SYSTEM INFORMATION:
SYSTEM SIZE:
3200W DC, 2320W AC,CEC RATING: 2883W
MODULES:
(8)HANWHA Q CELL QPEAK DUO BLK ML-G10
400W
INVERTER:
(8)ENPAHSE IQ8PLUS-72-2-US(240V)(SI-1)
BRANCH DETAILS:
1X8 ENPHASE BRANCH
SCOPE OF WORK
(E)UTILITY METER WITH
(N) MAIN SERVICE PANEL
CONDUIT RUN
PHOTOVOLTAIC ARRAY ON THE ROOF
STRING CONFIGURATION
BRANCH DETAILS
A 8 MODULES
(N) AC DISCONNECT
105'
65'
105'
5'
15'
7'
17'
(N) ENPHASE COMBINER 4
DETACHED STRUCTURE
PROPERTY LINE
GATE
GATE
DRIVE WAY
S
E
V
E
R
G
L
A
D
E
S
T
·ELECTRIC CODE:CEC 2019
·FIRE CODE:CFC 2019
·BUILDING CODE:CBC 2019
·RESIDENTIAL CODE:CRC 2019
3' FIRE SETBACK
1'-6" FIRE SETBACK
Structural
Only
BLDG# 101112797 ISS. 12/01/2022
ELEC# 20177987 ISS. 12/01/2022
The scope of the plans is for the installation of the solar photovoltaic system only and the
approval is subject to compliance with all applicable city and state codes and regulations
regarding construction. The approval of the plans does not constitute any certification of the
accuracy, completeness, or building permit status of the existing buildings and structures as
shown.
513 S Everglade Ave
12/20/22
A
MS
P
AC
CB
A
A
A
A
A
A
A
VICINITY MAP
ADDRESS:513 S EVERGLADE ST, SANTA
ANA, CA 92704
33.740912, -117.904046
APN:109-78-142
CUSTOMER INFORMATION
NAME:CECILIA TORRES
DATE:11/4/2022
SCALE:AS NOTED REV:B
AHJ:CA - CITY OF SANTA ANA
UTILITY:SCE
PRN NUMBER:MAS-64170
DRAFTED BY:
M.SAILESH
QC'ED BY:H.RAJ
PAPER SIZE:17"X11"
SOLARPLEX LLC
Dba MARAVILLA CONSTRUCTION
License#:1056065
5902 FIRESTONE BLVD
SOUTH GATE, CA 90280
TEL:(562) 806-6000
FAX:(562) 806-4006
APPLICABLE CODES
COVER PAGE
T-01
SCALE:1"=20'-0"
1.MODULES ARE LISTED UNDER UL 61730 AND
CONFORM TO THE STANDARDS.
2.INVERTERS ARE LISTED UNDER UL 1741 AND
CONFORM TO THE STANDARDS.
3.DRAWINGS ARE DIAGRAMMATIC, INDICATING
GENERAL ARRANGEMENT OF THE PV SYSTEM AND
THE ACTUAL SITE CONDITION MIGHT VARY.
4.WORKING CLEARANCES AROUND THE NEW PV
ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN
ACCORDANCE WITH CEC 110.26.
5.ALL GROUND WIRING CONNECTED TO THE MAIN
SERVICE GROUNDING IN MAIN SERVICE PANEL/
SERVICE EQUIPMENT.
6.ALL CONDUCTORS SHALL BE 600V, 75°C
STANDARD COPPER UNLESS OTHERWISE NOTED.
7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE
FOR INSPECTION IN COMPLIANCE WITH OSHA
REGULATIONS.
8.THE SYSTEM WILL NOT BE INTERCONNECTED BY
THE CONTRACTOR UNTIL APPROVAL FROM THE
LOCAL JURISDICTION AND/OR THE UTILITY.
9.ROOF ACCESS POINT SHALL BE LOCATED IN
AREAS THAT DO NOT REQUIRE THE PLACEMENT
OF GROUND LADDERS OVER OPENINGS SUCH AS
WINDOWS OR DOORS, AND LOCATED AT STRONG
POINTS OF BUILDING CONSTRUCTION WHERE THE
ACCESS POINT DOES NOT CONFLICT WITH
OVERHEAD OBSTRUCTIONS SUCH AS TREES,
WIRES OR SIGNS.
10.PV ARRAY COMBINER/JUNCTION BOX
PROVIDES TRANSITION FROM ARRAY WIRING TO
CONDUIT WIRING
GENERAL NOTES
SHEET CATALOG
INDEX NO. DESCRIPTION
T-01 COVER PAGE
S-01 MOUNTING DETAIL
S-02 STRUCTURAL DETAIL
E-01 SINGLE LINE DIAGRAM
PL-01 WARNING PLACARDS
SS SPEC SHEET(S)
SITE PLAN LAYOUT
CECILIA TORRES - 3.200kW DC, 2.320kW AC, CEC AC RATING:2.883kW
ENGINEERING SCOPE OF WORK
1.ILLUMINE INDUSTRIES INC. HAS ONLY PROVIDED DRAFTING SERVICES FOR THE PERMIT DRAWINGS. NO ACTUAL ENGINEERING WORK, ENGINEERING REVIEW OR ENGINEERING
APPROVAL HAS BEEN CONDUCTED BY ILLUMINE INDUSTRIES INC UNLESS NOTED OTHERWISE.
2.WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT
DRAWINGS, HE/SHE:
a. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN
b.IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN
c.HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN
GENERAL SYSTEM INFORMATION:
SYSTEM SIZE:
3200W DC, 2320W AC,CEC RATING: 2883W
MODULES:
(8)HANWHA Q CELL QPEAK DUO BLK ML-G10
400W
INVERTER:
(8)ENPAHSE IQ8PLUS-72-2-US(240V)(SI-1)
BRANCH DETAILS:
1X8 ENPHASE BRANCH
SCOPE OF WORK
(E)UTILITY METER WITH
(N) MAIN SERVICE PANEL
CONDUIT RUN
PHOTOVOLTAIC ARRAY ON THE ROOF
STRING CONFIGURATION
BRANCH DETAILS
A 8 MODULES
(N) AC DISCONNECT
105'
65'
105'
5'
15'
7'
17'
(N) ENPHASE COMBINER 4
DETACHED STRUCTURE
PROPERTY LINE
GATE
GATE
DRIVE WAY
S
E
V
E
R
G
L
A
D
E
S
T
·ELECTRIC CODE:CEC 2019
·FIRE CODE:CFC 2019
·BUILDING CODE:CBC 2019
·RESIDENTIAL CODE:CRC 2019
3' FIRE SETBACK
1'-6" FIRE SETBACK
6'
6'
B
513 S Everglade
Ave12/20/22
513 S Everglade
Ave12/20/22
Rev: 7/15/2021
RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
SOL-01 CBC 2019
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of
minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required.
Project Address:
Contractor Company Name:
Contractor License Number:
YES NO Are the following applicable to the proposed project?
1.Will the PV system layout provide the required three-foot wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
2.Will the PV system be installed on a roof having only one roofing layer with no
overlays?
3.Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
4.Will the PV system weigh maximum 4 pounds per square feet or less?
5.Will the PV system be installed where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
6.Will the PV system be installed with a space of 2” minimum to 10” maximum between
the underside of modules and the surface of the roof?
7.Will the PV system be installed without using any ballast system or counter-weight
system?
8.Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
9.Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch
embedment into roof rafters (with pre-drilled holes) and is this minimum embedment
shown on the plans?
10. Are ALL the structural pages of the plans stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer’s PV support information.)
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name: Signature:
Phone Number: Date:
Email Address:
Planning & Building Agency
Building Safety Division
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714) 647-5800
www.santa-ana.org
513 S Everglade Ave Santa Ana Ca 92704
SolarPlex LLC dba Maravilla Solar
1056065
Chris Vega
714-728-5185 11/01/2022
chris@maravillasolar.com
513 S Everglade
Ave12/20/22
-.e
Planning & Building Agency
Permits & Plan Check Section
20 Civic Center Plaza
P.O. Box 1988 (M-19)
Santa Ana, CA 92702
(714)647-5800
EXISTING ONE & TWO FAMILY DWELLINGS
ELECTRICAL SERVICES UNDERGROUND
EXCEPTION
CEC 2019 ELC-04
All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41-
626(b). There is a standing exception for existing one and two family dwellings. This exception
applies only when the new electrical service is designed to be fed from below grade as well as
overhead.
This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without
interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the
circuit breaker side of this cabinet.
Only listed combination overhead and underground feed service boxes may be used to connect to
an overhead utility drop. This exception to an underground fed service applies only to existing single
family and two family residences.
Rigid New service
Conduit location may NOT
Service
Entrance be under a patio
Conductor fl cover structure.
Riser -SCE
METER
PC��I�C�P
' Future
Underground
Service
Lateral
A surface -mounted combination service rquires no raceway provision for future underground feed.
When new service is semi -flush or flush mounted, a 3 inch rigid raceway is needed. Cap straight stub -
out at a depth of 12 inches below grade. A sweep is capped at 30 inches below grade.
Rev. 1/21/2020
wwwsanta-ana.org/pba/ Page 1 of 1