Loading...
HomeMy WebLinkAbout613 S Golden West Ave - PlanBldg permit #101109074 Elect permit #20175089, Issued on 01/10/2021 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Leticia Cisneros 961988 Aaron Wise/Complete Solar Cole Thacker cthacker@completesolar.com 09/22/2021 X X X X X X X X X X (877) 299-4943 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 x Yes = Comp shingle x Flashing x 613 S Golden West Ave01/10/22 613 S Golden West Ave01/10/22 LONGI LR4-60HPB-350M MODULES SOLAREDGE SE3800H-US RGM(240V) SOLAREDGE SE3800H-US RGM(240V) Square D 100 100 20A 12 x 10 2 6 1 x 10 1 EMT 3/4 Leticia Cisneros 613 GOLDEN WEST AVENUE SANTA ANA, CA 92703 10/26/2021 Cole Thacker COMPLETE SOLAR 3000 EXECUTIVE PKWY,STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 3.8kw 613 S Golden West Ave01/10/22 Longi LR4-60HPB-350m 40.4 8.99 20 350 DC1000 10.18 34.4 SolarEdge SOLAREDGE SE3800H-US RGM(240V) 380V-480V 3800 208 16 20 COMPLETE SOLAR 3000 EXECUTIVE PKWY,STE 504 SAN RAMON, CA 94583 LICENSE TYPE C10 LICENSE # 961988 PHONE # (877) 299-4943 Cole Thacker 3.8kw 613 GOLDEN WEST AVENUE SANTA ANA, CA 92703 Leticia Cisneros 613 S Golden West Ave01/10/22