Loading...
HomeMy WebLinkAbout615 W Park Ln - PlanACD INVMSP UM 65'-11" 11 7 ' - 8 " 11 7 ' - 8 " 65'-11" 3'-10" 29 ' - 9" 5'-10" 39 ' - 7" 1 PROJECT DESCRIPTION: PLOT PLAN & VICINITY MAP SCALE: 1/16" = 1'PV-1 SCALE: NTS PV-1 PLOT PLAN & VICINITY MAP 23X370 LONGI SOLAR:LR4-60HPH 370M 370W MODULE ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 8.51KW DC STC,6.00 kW AC CEC REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ARRAY LOCATIONS VICINITY MAP SCALE: NTSPV-1 2 HOUSE PHOTO EQUIPMENT SUMMARY 23 - LONGI SOLAR:LR4-60HPH 370M 370W MODULES 01 - SOLAREDGE TECHNOLOGY:SE6000H-US (240V) INVERTER 23 - SOLAREDGE POWER OPTIMIZERS S-440 PROJECT SITE SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8 OPTIMIZER CHART PV-9 EQUIPMENT ELEVATION PV-10+ EQUIPMENT SPECIFICATIONS 3 PAGE 1 OF 19 NOTES 1. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 2. MANUFACTURERS PRODUCT INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE AT THE TIME OF INSPECTION. 3. ALL SUBMITTALS WILL COMPLY WITH 2019 CEC, CBC, AND CFC. 4. SMOKE ALARMS AND CARBON MONOXIDE DETECTOR EQUIPMENT SHALL BE IN PLACE AT RESIDENCE ACCORDING TO THE CRC, CBC R314-315 REQUIREMENT. AHJ - SANTA ANA UTILITY - SCE ACCOUNT # - CA-R-195141 GOVERNING CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA RESIDENTIAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA FIRE CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. (E) GATE (E) FENCE ROOF #03 (02) LONGI SOLAR LR4-60HPH 370M 370W MODULES ROOF ACCESS POINT PROPERTY LINE PR O P E R T Y LI N E PROPERTY LINE PR O P E R T Y L I N E 1-STORY HOUSE EXISTING DRIVEWAY (N) MAIN SERVICE PANEL, 200A RATED, 240V, (SEMI-FLUSH MOUNT) (SIEMENS MC2442B1200EFV) (E) UTILITY METER (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT ROOF #01 (19) LONGI SOLAR LR4-60HPH 370M 370W MODULES W PARK LN (E) DETACHED STRUCTURE ROOF #02 (02) LONGI SOLAR LR4-60HPH 370M 370W MODULES REVISION BLDG # 101114458 ISS. 03/30/2023 Revision to 101112554 ISS. 10/31/2022 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 615 W Park Ln 04/03/23 1 1 8 ' - 2 " ACD INVMSP UM 65'-11" 1 1 7 ' - 8 " 1 1 7 ' - 8 " 65'-11" 3'-10" 29 ' - 9" 5'-10" 38 ' - 0" 1 PROJECT DESCRIPTION: PLOT PLAN & VICINITY MAP SCALE: 1/16" = 1'PV-1 SCALE: NTS PV-1 PLOT PLAN & VICINITY MAP 20X400 SOLARIA POWERXT:400R-PM 400W MODULE ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES SYSTEM SIZE: 8.00KW DC STC,6.00 kW AC CEC REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-1 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. ARRAY LOCATIONS VICINITY MAP SCALE: NTSPV-1 2 HOUSE PHOTO EQUIPMENT SUMMARY 20 - SOLARIA POWERXT:400R-PM 400W MODULES 01 - SOLAREDGE TECHNOLOGY:SE6000H-US (240V) INVERTER 20 - SOLAREDGE POWER OPTIMIZERS S-440 PROJECT SITE SHEET INDEX PV-1 PLOT PLAN & VICINITY MAP PV-2 ROOF PLAN & MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL LINE DIAGRAM PV-6 WIRING CALCULATIONS PV-7 PLACARDS PV-8 OPTIMIZER CHART PV-9 EQUIPMENT ELEVATION PV-10+ EQUIPMENT SPECIFICATIONS 3 PAGE 1 OF 19 NOTES 1. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 2. MANUFACTURERS PRODUCT INSTALLATION INSTRUCTIONS SHALL BE AVAILABLE AT THE TIME OF INSPECTION. 3. ALL SUBMITTALS WILL COMPLY WITH 2019 CEC, CBC, AND CFC. 4. SMOKE ALARMS AND CARBON MONOXIDE DETECTOR EQUIPMENT SHALL BE IN PLACE AT RESIDENCE ACCORDING TO THE CRC, CBC R314-315 REQUIREMENT. AHJ - SANTA ANA UTILITY - SCE ACCOUNT # - CA-R-195141 GOVERNING CODES THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODE 2019 CALIFORNIA ELECTRICAL CODE 2019 CALIFORNIA RESIDENTIAL CODE 2019 CALIFORNIA BUILDING CODE 2019 CALIFORNIA FIRE CODE 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE 2019 CALIFORNIA ENERGY CODE 2019 CALIFORNIA PLUMBING CODE 2020 NATIONAL ELECTRICAL CODE ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGENCIES. (E) GATE (E) FENCE ROOF #02 (01) SOLARIA POWERXT 400R-PM 400W MODULES ROOF ACCESS POINT PROPERTY LINE PRO P E RTY L I N E PROPERTY LINE PR O P E R T Y LI N E 1-STORY HOUSE EXISTING DRIVEWAY (N) MAIN SERVICE PANEL, 200A RATED, 240V, (SEMI-FLUSH MOUNT) (ALL IN ONE) (E) UTILITY METER (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT ROOF #01 (19) SOLARIA POWERXT 400R-PM 400W MODULES W PARK LN (E) DETACHED STRUCTURE Structural Only Bldg# 101112554 Issued: 10/31/22 Elec# 20177786 Issued: 11/01/22 615 W Park Ln 11/01/22 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH ELECTRICAL LINE DIAGRAM MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 200 A (NEW) NORTH (20) SOLARIA POWERXT 400R-PM 400W MODULES (01) SOLAREDGE TECHNOLOGY:SE6000H-US (240V) (20) SOLAREDGE POWER OPTIMIZERS S-440 (2) STRINGS OF 10 MODULES CONNECTED IN SERIES. SCALE: NTSPV-5 1 ELECTRICAL LINE DIAGRAM Tag # THWN-2 - Ground Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) THWN-2 1 1 2 2 3 Bare Copper Ground (EGC/GEC) THWN-2 PV WIRE 10 AWG 8 AWG THWN-2 - Ground Description Wire Gauge # of Conductors/Color 10 AWG 6 AWG 8 AWG 8 AWG 4 (2V+, 2V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 3 (1L1, 1L2, 1N) B/R/W 1 (GRN)3 INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(a) UTILITY FEED + SOLAR BACKFEED 200A + 35A = 235A BUSS RATING x 120% 200A x 120% = 240A 200 A (NEW) PAGE 5 OF 19 Conduit Type Conduit Size EMT 3/4" 3/4" 3/4" 3/4" EMT EMT EMT INSIDE EMT-ON ROOF INSIDE EMT-ON ROOF 3/4" 3/4" 3 L1 L2 N G = ACDC 3 L1 L2 L1 L2 N G N G AC DISCONNECT EATON#DG222URB 60A, 2P,240VAC NEMA 3R (N) MAIN BREAKER TO HOUSE 240V, 200A/2P, (TOP FED) (N) 35A/2P PV BREAKER AS FAR AS POSSIBLE FROM THE MAIN BREAKER BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V UTILITY PROVIDER :- SCE UTILITY METER # :- 222012-829412 SERVICE INFO UTILITY PROVIDER: SCE OVERHEAD SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 8.00 kW DC TOTAL AC SYSTEM SIZE: 6.00 kW AC (N) MAIN SERVICE PANEL, 200A RATED, 240V, (SEMI-FLUSH MOUNT) SIEMENS MC4040B1200SECW SIEMENS MC4040B1200SECW SOLAREDGE TECHNOLOGY: SE6000H-US OUTPUT: 240 VAC, 25.00A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT & INTEGRATED RAPID SHUTDOWN G N NL2L1 M TO UTILITY GRID 200A 35A/2P GROUNDING ELECTRODE SYSTEM · APPROVED MAIN SERVICE PANEL TO BE INSTALLED AT SITE JUNCTION BOX 600 V, NEMA 3 UL LISTED - + - + + - + + + + - - - 2 - + - 1 3 = = = = = = = = = = 2 1 09 10 SolarEdge Power Optimizer S-440 Rated DC Input Power - S-440 watts Maximum Input Voltage - 60 Vdc MPPT Range - 8 to 60 Vdc Maximum Input Current - 14.50 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5700 watts STC per string maximum SOLARIA POWERXT 400R-PM 400W MODULES - + - + + - + + + +- - - 2 - + - 1 3 = = = = = = = = = = 09 10 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH PLACARDS NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2019: 705.12(D)(3), NEC 2017: 705.12(D)(3), NEC 2011: 705.12(D)(4) DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(D)(2)(3)(c), NEC 2017: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): CEC 2019: 690.5(C), NEC 2017: 690.5(C), NEC 2011: 690.5(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 25.00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2011: 690.54 THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING ! LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): CEC 2019: 690.35(F), NEC 2017: 690.35(F), NEC 2011: 690.35(F) ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.17(E), NEC 2017: 690.17(E), NEC 2011: 690.17(4) WARNING! WARNING! WARNING! PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1) LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53, NEC 2011: 690.53 INVERTER #1 SOLAREDGE MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX. RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC- CONVERTER (IF INSTALLED) 480VDC 30.0ADC 21.05ADC PAGE 7 OF 19 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b), NEC 2011: 705.12(D)(7) WARNING ! CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN UTILITY METER & MAIN SERVICE PANEL AC DISCONNECT INVERTER (N) INVERTER (N) AC DSCONNECT (E) UTILITY METER (N) MAIN SERVICE PANEL (SEMI-FLUSH MOUNT) ALL IN ONE 615 W PARK LN 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-18 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 18 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-19 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 19 OF 19 615 W Park Ln 11/01/22 9/25/1997 by: John Sokolik STEP 1 Article 220.82 (B) (1),(2) 2541 General Lighting load 7,623 VA 3 Small Appliance 4,500 VA 1 Laundry circuit 1,500 VA 13,623 VA STEP 2 Article 220.82 (C)13,623 VA A/C Condenser & Fixed Electric Space Heating QTY Total 1 5,700 VA AHU 1 5,800 VA Heating Load 4,050 VA VA AHU 2 VA CU Load 6,500 VA VA AHU 3 VA VA AHU 4 VA 6,500 VA VA AHU 5 VA STEP 3 Article 220.82 (B) (3)9,920 VA 1 4,500 VA 1 1,400 VA VA 1 900 VA 1 1,030 VA VA 1 690 VA 1 400 VA 21,917 VA 1 1,000 VA VA 91 A VA VA 68 A VA VA 100 A VA VA 4 VA 4 VA 8 VA Copper VA VA VA 9,920 VA STEP 4 Article 220.82 (B) (3) STEP 5 Article 220.82 (B) (3) 5,760 W 8000 Cooktop Cooktop Oven(s) Oven(s) Number of appliances 0 Dem. Factor Cooktop & Oven Demand Load Pool Panel Feeder Calculation (See Note)A B N Continuous Non-continuous 0 . . . . . .0 0 0 Motors Motors 0 . . . . . .0 0 0 240v 240v . . . . . .0 0 240v 240v . . . . . .0 0 240v 240v . . . . . .0 0 240v 240v Pool Light 0 . . . . . .0 0 0 240v 240v Blower 2333 0 240v 0 0 0 other load 0 240v 0 0 0 0.0 other load 0 240v 0 0 0 Min.Copper Pool Feeder AWG A A A A Neut. loadPhase Amperes Water Heater Freezer Wine Clr Dishwasher Insta Hot Min.Service Req. >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Apply Demand Welder Well Pump Spa & Garage No Demand Continuous Motors 15 W PARK LN, Min. Feeder size Motor Neutral Load Ironing Center Another No Demand Jacuzzi Tub Pool Equip. Panel Pool heater 5 ton or Number of appliances Fountain Pump JOSH MCHALFFEY 0 Range Demand Load 0 SANTA ANA, CA 92706,USA Eq. Grding Cond. Col B demand Dryer Demand Load Gen.Lgt, Sm App.& Laun. Load Version 2011 L Demand Load 9/15/2022 19:25 Service Demand Electric Space Heat @ 65% <4, 40% >3, vs. A/C @ 100% Mini Refrig Residential Optional Calculation General lighting, Sm. Appl. & Laundry Refrigerator Appliance Demand Load Microwave Disposal Microwave Sprinkler Pump Neutral Demand R / Hood Col C demand Col B demand Total Appliance Load jmp1jds@comcast.net Max.Unbalanced Neutral Load Pool heater 3.5 ton Minimum Panel Rating Min. Neutral size Electric Clothes Dryers Col B demand Spa heater 11 kVA Col B demand Non-continuous Electric Ranges Check Box for Gas Range 615 W Park Ln 11/01/22 09/15/2022 RE: Structural Certification for Installation of Residential Solar JOSH MCHALFFEY:615 W PARK LN, SANTA ANA, CA 92706 Attn: To Whom It May Concern Design Criteria Code 2019 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 95 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition shingle roofing over roof plywood supported by 2X4 Rafters at 24 inches. The slope of the roof was approximated to be 20 degrees and the allowable maximum rafter span is 6 feet between supports. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com 615 W Park Ln 11/01/22 Structural Letter for PV Installation Date: 09/15/2022 Job Address: 615 W PARK LN SANTA ANA, CA 92706 Job Name: JOSH MCHALFFEY Job Number: 220915JM Scope of Work Table of Content Sheet 1 Cover 2 Attachment Uplift checks 3 Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2019 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 95 mph Exposure C References NDS for Wood Construction Sincerely, Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. projects@evengineersnet.com http://www.evengineersnet.com 615 W Park Ln 11/01/22 Wind Load Cont. 95 mph ASCE 7-16 Figure 26.5-1B C 1.0 ASCE 7-16 Sec 26.8.2 0.85 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 0.99 ASCE 7-16 Table 26.9-1 16.61 psf 20.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1) Zone(2r) Zone(2e)Zone(3) Fig. 30-3-2 GCp=-2.1 -2.6 -2.7 -2.7 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-41.85 -51.82 -53.81 -53.81 GCp=0.3 Figure 30.3-2 P=qh(GCp)(γE)(γa)=4.48 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing= 4 ft 5/16" Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity= 760 lbs Zone Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1) 4 11.0 222.0 82.3 Zone(2r) 4 11.0 271.3 82.3 Zone(2e) 4 11.0 281.2 82.3 Zone(3) 4 11.0 281.2 82.3 Conservative Max= 281.2 < 760 CONNECTION IS OK Risk Category = KZ = Kd = Ke = 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration projects@evengineersnet.com http://www.evengineersnet.com 615 W Park Ln 11/01/22 Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg= 0 psf Ct = 1.1 Ce = 0.9 Is = 1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1) 0 plf Max Length, L = 6.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT = 24in Dr = 10 psf 20 plf PvDL = 3 psf 12 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL= 36 plf Mdown= 162 lb-ft Mallowable = Sx x Fb' (wind)= 456 lb-ft > 162 lb-ft OK Load Case: DL+S Ps+ Ppvcos(θ)+PDL= 32 plf Mdown= 144 lb-ft Mallowable = Sx x Fb' (wind)= 456 lb-ft > 144 lb-ft OK Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL= 37.4 plf Max Moment, Mu= 168 lb-ft Mallowable = Sx x Fb' (wind)= 634 lb-ft > 168 lb-ft OK Pv max Shear= 82.3 lbs Shear, Vu=wL/2+Pv Point Load = 178 lbs Max Shear, Vu=wL/2+Pv Point Load = 178 lb Member Capacity DF-L No.2 2X4 CL CF Ci Cr KF φ λ Fb = 900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin = 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 3.5 in Width, b = 1.5 in Cross-Sectonal Area, A = 5.25 in2 Moment of Inertia, Ixx = 5.35938 in4 Section Modulus, Sxx = 3.0625 in Allowable Moment, M all = Fb'Sxx = 396.2 lb-ft DCR=Mu/Mall = 0.36 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A = 630.0 lb DCR=Vu/Vall = 0.28 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 615 W Park Ln 11/01/22 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 18% Dpv and Racking 3 psf Average Total Dead Load 10.6 psf Increase in Dead Load 2.2%OK Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - JOSH MCHALFFEY. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com 615 W Park Ln 11/01/22 ACD INVMSP UM JB REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 PROJECT ID J O S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH STRING LAYOUT 1 STRING LAYOUT PV-3 SCALE: 1/8" = 1'-0" PAGE 3 OF 19 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 20 SOLARIA POWERXT 400R-PM 400W MODULES INVERTER 01 SOLAREDGE TECHNOLOGY: SE6000H-US (240V) INVERTER INTEGRATED RAPID SHUTDOWN OPTIMIZER 20 SOLAREDGE POWER OPTIMIZERS S-440 AC DISCONNECT 1 AC DISCONNECT EATON#DG222URB 60A, 2P,240VAC NEMA 3R ATTACHMENT 71 CHIKOUSA L FOOT ATTACHMENTS RAILS 20 CHIKOUSA 7 RAILS 134" RAILS 0 CHIKOUSA 7 RAILS 166" RAIL SPLICE 6 SPLICE KIT MID CLAMPS 20 MID CLAMPS END CLAMPS 40 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 10 GROUNDING LUG STRING 1 STRING 2 (E) FRONT OF RESIDENCE W PARK LN (E) BACK OF RESIDENCE Structural Only 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # SOLARIA POWERXT 400R-PM 400 (400W)MODULES VMP 42.4 IMP 9.41 VOC 51.1 ISC 9.82 MODULE DIMENSION 64.72"L x 47.4"W x 1.38"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE TECHNOLOGY SE6000H-US NOMINAL AC POWER 6.00KW NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 25.00A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2° AMBIENT TEMP (HIGH TEMP 2%)31° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 53° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.29%/°C EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 15.34A 1.25 X 1.25 X MODULE ISC DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 30.72ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (15.34A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c)+22° EXPECTED WIRE TEMP (In Celsius)31 +22 = 53 TEMP. CORRECTION PER TABLE (310.16)0.76 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.75A 1.25 X OPTIMIZER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 24.32ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO MAIN SERVICE PANEL: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)31 TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1 CIRCUIT CONDUCTOR SIZE 8AWG CIRCUIT CONDUCTOR AMPACITY 55A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 31.25A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 52.80A TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity PAGE 6 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH OPTIMIZER CHART 1-10 1 2 3 4 11-20 21-30 31-40 41-50 51-60 5 6 7 8 9 10 OPTIMIZER CHART PAGE 8 OF 19 W PARK LN 615 W Park Ln 11/01/22 1 0 ' REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT ELEVATION PAGE 9 OF 19 EQUIPMENT ELEVATION SCALE: NTS 1 PV-9 (N) MAIN SERVICE PANEL, 200A RATED, 240V, (SEMI-FLUSH MOUNT) ALL IN ONE (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (E) UTILITY METER (N) AC DISCONNECT 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 10 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 11 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 12 OF 19 615 W Park Ln 11/01/22 ACD INVMSP UM JB 1'-5"43'-9"9'-6" REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 PROJECT ID J O S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH ROOF PLAN & MODULES ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 20°2° 2"x4"24" o.c. #2 20°272° 2"x4"24" o.c. LEGEND - JUNCTION BOX MSP - MAIN SERVICE PANEL - VENTS, DISH (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT - UTILITY METER SCALE: 1/8" = 1'-0" - SOLAREDGE OPTIMIZER MODULE TYPE, DIMENSIONS & WEIGHT ACD - AC DISCONNECT - INVERTER 1 PV-2 NUMBER OF MODULES = 20 MODULES MODULE TYPE = SOLARIA POWERXT 400R-PM 400W MODULES MODULE WEIGHT = 46 LBS / 20.9 KG. COMPONENT WEIGHT: 1.5 LBS. PER MODULE TOTAL DEAD LOAD: 950.00 LBS. POINT LOAD PER STANDOFF.: 950.00 LBS / 71 STANDOFF = 13.38 LBS MODULE DIMENSIONS = 64.72"x 47.4" = 21.30 SF UNIT WEIGHT OF ARRAY = 2.23 PSF UM JB INV ARRAY AREA WITH TOTAL ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 19 404.77 818.11 49.48 #2 1 21.30 95.48 22.31 ROOF PLAN & MODULES PAGE 2 OF 19 ARRAY AREA WITH WHOLE ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1-2 20 426.07 2306.14 18.48 SOLARIA POWERXT 400R-PM 400W MODULES 47.4" 64 . 7 2 " (E) CHIMNEY (E) BACK OF RESIDENCE (E) FRONT OF RESIDENCE W PARK LN 3/4" EMT CONDUIT RUN ON ROOF (N) JUNCTION BOX ROOF #02 (01) SOLARIA POWERXT 400R-PM 400W MODULES ROOF ACCESS POINT (N) MAIN SERVICE PANEL, 200A RATED, 240V, (SEMI-FLUSH MOUNT) ALL IN ONE (E) UTILITY METER (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT ROOF #01 (19) SOLARIA POWERXT 400R-PM 400W MODULES (71 ) CHIKOUSA COMPOSITION L-FOOT ATTACHMENTS @48"O.C. (20) SOLAREDGE POWER OPTIMIZER P-S-440 (N) CHIKOUSA 7 RAILS RACKING SYSTEM ROOF #1 TILT - 20° AZIM. - 02° ROOF #2 TILT - 20° AZIM. - 272° 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 1 8" FIRE SETBACK 36" FIRE SETBACK 36" FIRE SETBACK 36" FIRE SETBACK 18 " F I R E S E T B A C K 18 " F I R E S E T B AC K Structural Only 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH ATTACHMENT DETAIL PAGE 4 OF 19 SCALE: NTS 2 PV-4 ATTACHMENT DETAIL SCALE: NTS 1 PV-4 ATTACHMENT DETAIL(enlarged view) PV MODULE SEE (2/PV-4) FOR ENLARGED VIEW (E) SINGLE LAYER OF COMP SHINGLE PV MODULES CHIKOUSA 7 RAILS FLASHING COMPOSITION L FOOT ATTACHMENT (E) SINGLE LAYER OF COMP SHINGLE GROUNDING & END/MID CLAMP CHIKO ASPHALT ROOF RACKING SYSTEM 2"x4" RAFTERS @ 24" O.C. 5/16" x 3 1/2" SS LAG BOLT INTO RAFTER(S) 2 1/2" MIN. PENETRATION SEALED W/ GEOCEL. CHIKOUSA CHANNEL NUT 2"X4" RAFTE R S @ 24"O.C. 6" Structural Only 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 13 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 14 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-15 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 15 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-16 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 16 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-17 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH EQUIPMENT SPECIFICATION PAGE 17 OF 19 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-18 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 18 OF 19 Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 615 W Park Ln 11/01/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 615 W Park Ln 11/01/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan                                                          Nerd Power LLC 2065 W Obispo Ave Suite 102 Josh Mchalffey Gilbert, AZ 85233 615 W Park Ln Santa Ana CA 92706 6.00 kW 615 W Park Ln 11/01/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram                                                                                                                                                                                                                                                   Nerd Power LLC 2065 W Obispo Ave Suite 102 Josh Mchalffey Gilbert, AZ 85233 615 W Park Ln Santa Ana CA 92706 6.00 kW 615 W Park Ln 11/01/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a)12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b)10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Nerd Power LLC 2065 W Obispo Ave Suite 102 Josh Mchalffey Gilbert, AZ 85233 615 W Park Ln Santa Ana CA 92706 6.00 kW 615 W Park Ln 11/01/22 615 W Park Ln 11/01/22 Rev: 8/29/19 SOL-01 CBC 2016 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST Zachariah V Michicoff 310-598-2412 Nerd Power LLC 1019100 caprocessing@nerdpower.energy 615 W Park Ln Santa Ana CA 92706 9/9/22 615 W Park Ln 11/01/22 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-5 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH 08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV ELECTRICAL LINE DIAGRAM MAIN SERVICE VOLTAGE: MAIN PANEL BRAND: MAIN SERVICE PANEL: MAIN BREAKER RATING: MAIN SERVICE LOCATION: SERVICE FEED SOURCE: 240V 200 A (NEW) NORTH (23)LONGI SOLAR LR4-60HPH 370M 370W MODULES (01)SOLAREDGE TECHNOLOGY:SE6000H-US (240V) (23)SOLAREDGE POWER OPTIMIZERS S-440 (1)STRING OF 12 MODULES CONNECTED IN SERIES & (1)STRING OF 11 MODULES CONNECTED IN SERIES. SCALE: NTSPV-5 1 ELECTRICAL LINE DIAGRAM Tag # THWN-2 - Ground Conduit Conductor Schedule (ALL CONDUCTORS MUST BE COPPER) THWN-2 1 1 2 2 3 Bare Copper Ground (EGC/GEC) THWN-2 PV WIRE 10 AWG 8 AWG THWN-2 - Ground Description Wire Gauge # of Conductors/Color 10 AWG 6 AWG 8 AWG 8 AWG 4 (2V+, 2V-) 1 BARE 4 (2V+, 2V-) B/R 1 (GRN) 3 (1L1, 1L2, 1N) B/R/W 1 (GRN)3 INTERCONNECTION 120% RULE - NEC 705.12(B)(2)(3)(a) UTILITY FEED + SOLAR BACKFEED 200A + 35A = 235A BUSS RATING x 120% 225A x 120% = 270A 200 A (NEW) PAGE 5 OF 19 Conduit Type Conduit Size EMT 3/4" 3/4" 3/4" 3/4" EMT EMT EMT INSIDE EMT-ON ROOF INSIDE EMT-ON ROOF 3/4" 3/4" 3 L1 L2 N G = AC DC 3 L1 L2 L1 L2 N G N G AC DISCONNECT EATON#DG222URB 60A, 2P,240VAC NEMA 3R (N)MAIN BREAKER TO HOUSE 240V, 200A/2P, (TOP FED) (N)35A/2P PV BREAKER AS FAR AS POSSIBLE FROM THE MAIN BREAKER BI-DIRECTIONAL UTILITY METER 1-PHASE, 3-W, 120V/240V UTILITY PROVIDER :- SCE UTILITY METER # :- 222012-829412 SERVICE INFO UTILITY PROVIDER:SCE OVERHEAD SYSTEM SIZE: TOTAL DC SYSTEM SIZE: 8.51 kW DC TOTAL AC SYSTEM SIZE: 6.00 kW AC (N)MAIN SERVICE PANEL, 200A WITH 225A BUS RATED, 240V, (SEMI-FLUSH MOUNT) (SIEMENS MC2442B1200EFV) SIEMENS MC2442B1200EFV SOLAREDGE TECHNOLOGY: SE6000H-US OUTPUT: 240 VAC, 25.00A 99% CEC WEIGHTED EFFICIENCY NEMA 3R, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT & INTEGRATED RAPID SHUTDOWN G N NL2L1 M TO UTILITY GRID 200A 35A/2P GROUNDING ELECTRODE SYSTEM · APPROVED MAIN SERVICE PANEL TO BE INSTALLED AT SITE JUNCTION BOX 600 V, NEMA 3 UL LISTED - + - + + - + + + + - - - 2 - + - 1 3 = = = = = = = = = = 2 1 11 12 SolarEdge Power Optimizer S-440 Rated DC Input Power - S-440 watts Maximum Input Voltage - 60 Vdc MPPT Range - 8 to 60 Vdc Maximum Input Current - 14.50 Adc Maximum Output Current - 15 Adc String Limitations - 8 to 25 Optimizers, 5700 watts STC per string maximum LONGI SOLAR LR4-60HPH 370M 370W MODULES - + - + + - + + + +- - - 2 - + - 1 3 = = = = = = = = = = 10 11 Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATEDESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022REV B11/15/2022REV C12/30/2022REV PLACARDS NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017 ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-7 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY LABEL LOCATION: UTILITY SERVICE METER AND MAIN SERVICE PANEL. PER CODE(S): CEC 2019: 705.12(D)(3), NEC 2017: 705.12(D)(3), NEC 2011: 705.12(D)(4) DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(D)(2)(3)(c), NEC 2017: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4) WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): CEC 2019: 690.31(G)(3), 690.31(G)(4), NEC 2017: 690.31(G)(3), 690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012: 605.11.1.4 ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED LABEL LOCATION: INVERTER(S), ENPHASE ENVOY ENCLOSURE (IF APPLICABLE). PER CODE(S): CEC 2019: 690.5(C), NEC 2017: 690.5(C), NEC 2011: 690.5(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 25.00 AMPS 240 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54, NEC 2017: 690.54, NEC 2011: 690.54 THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING ! LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): CEC 2019: 690.35(F), NEC 2017: 690.35(F), NEC 2011: 690.35(F) ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.17(E), NEC 2017: 690.17(E), NEC 2011: 690.17(4) WARNING! WARNING! WARNING! PHOTOVOLTAIC SYSTEM DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1) LABEL LOCATION: INVERTER(S), DC DISCONNECT(S). PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.53, NEC 2011: 690.53 INVERTER #1 SOLAREDGE MAXIMUM VOLTAGE MAXIMUM CIRCUIT CURRENT MAX. RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC- CONVERTER (IF INSTALLED) 480VDC 30.0ADC 22.39ADC PAGE 7 OF 19 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b), NEC 2017: 705.12(B)(2)(3)(b), NEC 2011: 705.12(D)(7) WARNING ! CAUTION: POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN UTILITY METER & MAIN SERVICE PANEL AC DISCONNECT INVERTER (N) INVERTER (N) AC DSCONNECT (E) UTILITY METER (N) MAIN SERVICE PANEL (SEMI-FLUSH MOUNT) (SIEMENS MC2442B1200EFV) 615 W PARK LN Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 ACD INVMSP UM JB REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-3 PROJECT ID J O S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV STRING LAYOUT 1 STRING LAYOUT PV-3 SCALE: 1/8" = 1'-0" PAGE 3 OF 19 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 23 LONGI SOLAR LR4-60HPH 370M 370W MODULES INVERTER 01 SOLAREDGE TECHNOLOGY: SE6000H-US (240V) INVERTER INTEGRATED RAPID SHUTDOWN OPTIMIZER 23 SOLAREDGE POWER OPTIMIZERS S-440 AC DISCONNECT 1 AC DISCONNECT EATON#DG222URB 60A, 2P,240VAC NEMA 3R ATTACHMENT 75 CHIKOUSA L FOOT ATTACHMENTS RAILS 0 CHIKOUSA 7 RAILS 134" RAILS 21 CHIKOUSA 7 RAILS 166" RAIL SPLICE 10 SPLICE KIT MID CLAMPS 30 MID CLAMPS END CLAMPS 32 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 8 GROUNDING LUG STRING 1 STRING 2 (E) FRONT OF RESIDENCE W PARK LN (E) BACK OF RESIDENCE Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-6 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV WIRING CALCULATIONS ELECTRICAL NOTES 1.) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2.) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3.) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4.) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. 5.) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6.) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7.) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8.) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9.) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10.) THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 4-6 7-9 10-20 PERCENT OF VALUES .80 .70 .50 DC CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL # LONGI SOLAR LR4-60HPH 370M 370 (370W)MODULES VMP 34.4 IMP 10.76 VOC 40.9 ISC 11.52 MODULE DIMENSION 69.09"L x 40.87"W x 1.38"D (In Inch) INVERTER SPECIFICATIONS MANUFACTURER / MODEL #SOLAREDGE TECHNOLOGY SE6000H-US NOMINAL AC POWER 6.00KW NOMINAL OUTPUT VOLTAGE 240 VAC NOMINAL OUTPUT CURRENT 25.00A AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2° AMBIENT TEMP (HIGH TEMP 2%)31° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 53° CONDUCTOR TEMPERATURE RATE 90° MODULE TEMPERATURE COEFFICIENT OF Voc -0.27%/°C EXPECTED WIRE TEMP (In Celsius)31° TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10 AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.00A 1.25 X 1.25 X MODULE ISC DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 30.72ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.00A) otherwise less the entry for circuit conductor size and ampacity DC CONDUCTOR AMPACITY CALCULATIONS: FROM JUNCTION BOX TO INVERTER: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c)+22° EXPECTED WIRE TEMP (In Celsius)31 +22 = 53 TEMP. CORRECTION PER TABLE (310.16)0.76 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 18.75A 1.25 X OPTIMIZER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 24.32ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (18.75A) otherwise less the entry for circuit conductor size and ampacity AC CONDUCTOR AMPACITY CALCULATIONS: FROM INVERTER TO MAIN SERVICE PANEL: No. OF INVERTER 1 EXPECTED WIRE TEMP (In Celsius)31 TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1 CIRCUIT CONDUCTOR SIZE 8AWG CIRCUIT CONDUCTOR AMPACITY 55A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 31.25A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 52.80A TEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (31.25A) otherwise less the entry for circuit conductor size and ampacity PAGE 6 OF 19 Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-8 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV OPTIMIZER CHART 1-10 1 2 3 4 11-20 21-30 31-40 41-50 51-60 5 6 7 8 9 10 OPTIMIZER CHART PAGE 8 OF 19 W PARK LN Exp. Date:09/30/24 2/3/23 615 W Park Ln 04/03/23 1 0 ' - 0 " REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-9 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT ELEVATION PAGE 9 OF 19 EQUIPMENT ELEVATION SCALE: NTS 1 PV-9 (N) MAIN SERVICE PANEL, 200A RATED, 240V, (SEMI-FLUSH MOUNT) (SIEMENS MC2442B1200EFV) (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (E) UTILITY METER (N) AC DISCONNECT Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-10 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 10 OF 19 Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-11 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 11 OF 19 Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-12 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 12 OF 19 Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23 ACD INVMSP UM JB 1 ' -8 " 1 0 ' - 5 " 2' - 7" 3'-6"44'-2"7'-0" REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-2 PROJECT ID J O S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV ROOF PLAN & MODULES ROOF DESCRIPTION ROOF TYPE COMP SHINGLE ROOF ROOF ROOF TILT AZIMUTH RAFTERS SIZE RAFTERS SPACING #1 20°2° 2"x4"24" o.c. #2 20°272° 2"x4"24" o.c. #3 20°92° 2"x4"24" o.c. LEGEND - JUNCTION BOX MSP - MAIN SERVICE PANEL - VENTS, DISH (ROOF OBSTRUCTION) - ROOF ATTACHMENT - RAFTERS - CONDUIT - UTILITY METER SCALE: 1/8" = 1'-0" - SOLAREDGE OPTIMIZER MODULE TYPE, DIMENSIONS & WEIGHT ACD - AC DISCONNECT - INVERTER 1 PV-2 NUMBER OF MODULES = 23 MODULES MODULE TYPE = LONGI SOLAR LR4-60HPH 370M 370W MODULES MODULE WEIGHT = 42.99 LBS / 19.5 KG. COMPONENT WEIGHT: 1.5 LBS. PER MODULE TOTAL DEAD LOAD: 1023.27 LBS. POINT LOAD PER STANDOFF.: 1023.27 LBS / 75 STANDOFF = 13.64 LBS MODULE DIMENSIONS = 69.09"x 40.87" = 19.61 SF UNIT WEIGHT OF ARRAY = 2.27 PSF UM JB INV ARRAY AREA WITH TOTAL ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 19 372.57 818.11 45.54 #2 2 39.22 95.48 41.07 #3 2 39.22 100.49 39.03 ROOF PLAN & MODULES PAGE 2 OF 19 ARRAY AREA WITH WHOLE ROOF AREA ROOF # OF MODULES ARRAY AREA (Sq. Ft.) TOTAL ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1-3 23 451.01 2306.14 19.56 LONGI SOLAR LR4-60HPH 370M 370W MODULES 40.87" 69 . 0 9 " (E) CHIMNEY (E) BACK OF RESIDENCE (E) FRONT OF RESIDENCE W PARK LN 3/4" EMT CONDUIT RUN ON ROOF (N) JUNCTION BOX ROOF #02 (02) LONGI SOLAR LR4-60HPH 370M 370W MODULES ROOF ACCESS POINT (N) MAIN SERVICE PANEL, 200A RATED, 240V, (SEMI-FLUSH MOUNT) (SIEMENS MC2442B1200EFV)(E) UTILITY METER (N) SOLAREDGE TECHNOLOGY : SE6000H-US INVERTER INTEGRATED RAPID SHUTDOWN (N) AC DISCONNECT ROOF #01 (19) LONGI SOLAR LR4-60HPH 370M 370W MODULES (75) CHIKOUSA COMPOSITION L-FOOT ATTACHMENTS @48"O.C. (23) SOLAREDGE POWER OPTIMIZER S-440 (N) CHIKOUSA 7 RAILS RACKING SYSTEM ROOF #1 TIL T - 20° AZIM. - 02° ROOF #2 TIL T - 20° AZIM. - 272° 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 18" FIRE SETBACK 36" FIRE SETBACK 1 8 " F I R E S E T B A CK 1 8" F I R E S E T B A C K 1 8 " F I R E S E T B A C K 1 8 " F I R E S E T BA C K 36" F I R E S E T B A C K ROOF #03 (02) LONGI SOLAR LR4-60HPH 370M 370W MODULES ROOF #3 TILT - 20° AZIM. - 92° Structural Only Signed 3/13/2023 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-4 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV ATTACHMENT DETAIL PAGE 4 OF 19 SCALE: NTS 2 PV-4 ATTACHMENT DETAIL SCALE: NTS 1 PV-4 ATTACHMENT DETAIL(enlarged view) PV MODULE SEE (2/PV-4) FOR ENLARGED VIEW (E)SINGLE LAYER OF COMP SHINGLE PV MODULES CHIKOUSA 7 RAILS FLASHING COMPOSITION L FOOT ATTACHMENT (E)SINGLE LAYER OF COMP SHINGLE GROUNDING & END/MID CLAMP CHIKO ASPHALT ROOF RACKING SYSTEM 2"x4" RAFTERS @ 24" O.C. 5/16" x 3 1/2" SS LAG BOLT INTO RAFTER(S) 2 1/2" MIN. PENETRATION SEALED W/ GEOCEL. CHIKOUSA CHANNEL NUT 2"X4" RAFTE R S @ 24"O.C. 6" Signed 2/7/2023 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-13 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 13 OF 19 Structural Only Signed 3/13/2023 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-14 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 14 OF 19 Structural Only Signed 3/13/2023 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-15 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 15 OF 19 Structural Only Signed 3/13/2023 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-16 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 16 OF 19 Structural Only Signed 3/13/2023 615 W Park Ln 04/03/23 REV SHEET NAME SHEET SIZE SHEET NUMBER ANSI B 11" X 17" DATE DESCRIPTION REVISIONS Signature with Seal PROJECT NAME & ADDRESS PV-17 PROJECT ID JO S H M C H A L F F E Y 61 5 W P A R K L N , SA N T A A N A , C A 9 2 7 0 6 , U S A FRESH08/31/2022 ORIGINAL PLAN 2065 W OBISPO AVE #102 GILBERT, AZ 85233 USA 866-572-2637 LIC # CA-1019100 ABHISHEK MAHESH A10/11/2022 REV B11/15/2022 REV C12/30/2022 REV EQUIPMENT SPECIFICATION PAGE 17 OF 19 Exp. Date: 09/30/24 2/3/23 615 W Park Ln 04/03/23