625 W Columbine Ave - Plan
Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Better Earth 1024460 x x x x x x x x x x Mark Hellsund Mark Hellsund 661-470-2108 08/30/2022 Mark.H@Betterearth.solar 625 W Columbine Ave 625 W Columbine Ave09/19/22 240 volts 125 Main Breaker: 100 625 W Columbine Ave - Rev #2017748409/28/22 1 APT test conditions according to IEC / TS 62804-1:2015, method A (−1500 V, 96 h) 2 See data sheet on rear for further information. THE IDEAL SOLUTION FOR: Rooftop arrays on residential buildings BREAKING THE 20 % EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 20.9 %. THE MOST THOROUGH TESTING PROGRAMME IN THE INDUSTRY Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new “Quality Controlled PV” of the independent certification institute TÜV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low-light and temperature behaviour. ENDURING HIGH PERFORMANCE Long-term yield security with Anti LID Technology, Anti PID Technology1, Hot-Spot Protect and Traceable Quality Tra.Q™. EXTREME WEATHER RATING High-tech aluminium alloy frame, certified for high snow (5400 Pa) and wind loads (4000 Pa). A RELIABLE INVESTMENT Inclusive 25-year product warranty and 25-year linear performance warranty2. Q.PEAK DUO BLK-G10+ 350-370 ENDURING HIGH PERFORMANCE PR E L I M I N A R Y 625 W Columbine Ave09/19/22 625 W Columbine Ave - Rev #2017748409/28/22 DETAIL A 16 mm 8.5 mm21.25 mm 980 mm 1717 mm 4 × Mounting slots (DETAIL A) Frame 1045 mm 32 mm 8 × Drainage holes 368.5 mm 4 × Grounding points ø 4.5 mm Label ≥ 1150 mm ≥ 1150 mm 1002.5 mm RE L A T I V E E F F I C I E N C Y CO M P A R E D T O N O M I N A L P O W E R [ % ] YEARS Q CELLS Industry standard for linear warranties* *Standard terms of guarantee for the 10 PV companies with the highest production capacity in 2014 (as at: September 2014) 100 95 90 85 80 15 5 25200 10 98 86 200 400 600 800 1000 110 100 90 80 RE L A T I V E E F F I C I E N C Y [ % ] IRRADIANCE [W/m²] α [% / K]+0.04 β [% / K] −0.27 γ [% / K]−0.34 NMOT [°C] 43 ± 3 [V]1000 [A]20 C / TYPE 2 [Pa] 3600 / 2660 −40 °C - +85 °C [Pa] 5400 / 4000 350 355 360 365 370 [W]350 355 360 365 370 [A]10.97 11.00 11.04 11.07 11.10 [V]41.11 41.14 41.18 41.21 41.24 [A]10.37 10.43 10.49 10.56 10.62 [V]33.76 34.03 34.31 34.58 34.84 [%]≥ 19.5 ≥ 19.8 ≥ 20.1 ≥ 20.3 ≥ 20.6 [W]262.6 266.3 270.1 273.8 277.6 [A]8.84 8.87 8.89 8.92 8.95 [V]38.77 38.80 38.83 38.86 38.90 [A]8.14 8.20 8.26 8.31 8.37 [V]32.24 32.48 32.71 32.94 33.17 Hanwha Q CELLS GmbH Sonnenallee 17-21, 06766 Bitterfeld-Wolfen, Germany | TEL +49 (0)3494 66 99-23444 | FAX +49 (0)3494 66 99-23000 | EMAIL sales@q-cells.com | WEB www.q-cells.com Note: Installation instructions must be followed. See the installation and operating manual or contact our technical service department for further information on approved installation and use of this product. Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE At least 98 % of nominal power dur- ing first year. Thereafter max. 0.5 % degradation per year. At least 93.5 % of nominal power up to 10 years. At least 86 % of nominal power up to 25 years. All data within measurement toler- ances. Full warranties in accordance with the warranty terms of the Q CELLS sales organisation of your respective country. Typical module performance under low irradiance conditions in comparison to STC conditions (25 °C, 1000 W/m2). Sp e c i f i c a t i o n s s u b j e c t t o t e c h n i c a l c h a n g e s © Q C E L L S Q. P E A K D U O B L K - G 1 0 + _ 3 5 0 - 3 7 0 _ 2 0 2 1 - 0 8 _ R e v 0 1 _ E N PROPERTIES FOR SYSTEM DESIGN Maximum System Voltage VSYS PV module classification Class II Maximum Reverse Current IR Fire Rating based on ANSI / UL 61730 Max. Design Load, Push / Pull Permitted Module Temperature on Continuous DutyMax. Test Load, Push / Pull ELECTRICAL CHARACTERISTICS POWER CLASS MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC1 (POWER TOLERANCE +5 W / −0 W) Mi n i m u m Power at MPP1 PMPP Short Circuit Current1 ISC Open Circuit Voltage1 VOC Current at MPP IMPP Voltage at MPP VMPP Efficiency1 η MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Mi n i m u m Power at MPP PMPP Short Circuit Current ISC Open Circuit Voltage VOC Current at MPP IMPP Voltage at MPP VMPP 1Measurement tolerances P MPP ± 3 %; ISC; VOC ± 5 % at STC: 1000 W/m2, 25 ± 2 °C, AM 1.5 according to IEC 60904-3 • 2 800 W/m², NMOT, spectrum AM 1.5 MECHANICAL SPECIFICATION Format 1717 mm × 1045 mm × 32 mm (including frame) Weight 19.9 kg Front Cover 3.2 mm thermally pre-stressed glass with anti-reflection technology Back Cover Composite film Frame Black anodised aluminium Cell 6 × 20 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm × 32-60 mm × 15-18 mm Protection class IP67, with bypass diodes Cable 4 mm² Solar cable; (+) ≥ 1150 mm, (−) ≥ 1150 mm Connector Stäubli MC4; IP68 TEMPERATURE COEFFICIENTS Temperature Coefficient of ISC Temperature Coefficient of VOC Temperature Coefficient of PMPP Nominal Module Operating Temperature QUALIFICATIONS AND CERTIFICATES Quality Controlled PV - TÜV Rheinland; IEC 61215:2016; IEC 61730:2016. This data sheet complies with DIN EN 50380. QCPV Certification ongoing. 625 W Columbine Ave09/19/22 625 W Columbine Ave - Rev #2017748409/28/22 IN V E R T E R S solaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR WARRANTY 625 W Columbine Ave09/19/22 CS3N-380|385|390|395|400MS 380 W ~ 400 W BLACK FRAME ON BLACK BACKSHEET MONO PERC MODULE MORE RELIABLE Comprehensive LID / LeTID mitigation technology, up to 50% lower degradation Module power up to 400 W Module efficiency up to 19.7%400 W Better shading tolerance Minimizes micro-crack impacts MORE POWER Lower LCOE & BOS cost HiKuBlack Heavy snow load up to 5400 Pa, enhanced wind load up to 2400 Pa* products you order or use. Please contact your local Canadian Solar sales representative in which the products will be used. PRODUCT CERTIFIC ATES* MANAGEMENT SYSTEM CERTIFICATES* IEC 61215 / IEC 61730 / CE FSEC (US Florida) UL 61730 / IEC 61701 / IEC 62716 CANADIAN SOLAR (USA), INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. Canadian Solar was recognized as the No. 1 module supplier for quality and performance/price ratio in the IHS Module Customer Insight Survey, and is a leading PV project developer and manufacturer of solar modules, with over 55 GW deployed around the world since 2001. * For detailed information, please refer to the Installation Manual. CANADIAN SOLAR (USA), INC. 3000 Oak Road, Suite 400, Walnut Creek, CA 94597, USA | www.csisolar.com/na | service.ca @csisolar.com 1 st year power degradation no more than 2% Subsequent annual power degradation no more than 0.55% 25 Years Years Linear Power Performance Warranty* Industry Leading Product Warranty on Materials and Workmanship* 625 W Columbine Ave - Rev #2017748409/28/22 MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Single Phase Inverter with HD-Wave Technology for North America 625 W Columbine Ave09/19/22 PARTNER SECTION ENGINEERING DRAWING (mm)CS3N-400MS / I-V CURVES products due to the on-going innovation and product enhancement. CSI Solar Co., Ltd. reserves the right to make necessary adjustment to the information described herein at any time without further notice. professional skills and please carefully read the safety and installation instructions before using our PV modules. MECHANICAL DATA Data Cell Type Mono-crystalline Cell Arrangement 132 [2 X (11 X 6) ] Dimensions Weight Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy Cable 4 mm2 (IEC), 12 AWG (UL) Cable Length (Including Connector) 1650 mm (65.0 in) (-) / 1000 mm (39.4 in) (+)* Connector T4 series or MC4 Per Pallet 30 pieces 720 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. TEMPERATURE CHARACTERISTICS Data -0.34 % / °C -0.26 % / °C 0.05 % / °C Nominal Module Operating Temperature 41 ± 3°C V A 12 11 10 7 6 5 4 3 2 1 0 V A 1000 W/m 2 2 600 W/m2 400 W/m2 200 W/m2 5°C 25°C 45°C 65°C 12 11 10 7 6 5 4 3 2 1 0 06 5 5 0 5 5 4 0 4 5 3 0 3 5 2 0 2 5 1 0 1 5 06 5 5 0 5 5 4 0 4 5 3 0 3 5 2 0 2 5 1 0 1 5 Rear View Mounting Hole 1 1 5 5 1 3 0 0 1 000 6- 5 Grounding Hole Mounting Hole A A B B 1 4 Frame Cross Section A - A B - B 25 35 35 35 ELECTRICAL DATA | STC* CS3N 380MS 385MS 390MS 395MS 400MS 380 W 385 W 390 W 395 W 400 W Opt. Operating Voltage (Vmp)36.4 V 36.6 V 36.8 V 37.0 V 37.2 V Opt. Operating Current (Imp) 10.44 A 10.52 A 10.60 A 10.68 A 10.76 A Open Circuit Voltage (Voc) 43.7 V 43.9 V 44.1 V 44.3 V 44.5 V Short Circuit Current (Isc) 11.26 A 11.32 A 11.38 A 11.44 A 11.50 A 19.2% 19.4% 19.7%18.7% 18.9% Operating Temperature 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 61730 1500V) or TYPE 2 (UL 61730 1000V) or CLASS C (IEC 61730) 20 A Class A Power Tolerance * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS3N 380MS 385MS 390MS 395MS 400MS 285 W 34.1 V 8.35 A 41.3 V 9.08 A 289 W 34.3 V 8.42 A 41.5 V 9.13 A 293 W 34.5 V 8.48 A 41.7 V 9.18 A 296 W 34.7 V 8.54 A 41.9 V 9.22 A 300 W 34.9 V 8.60 A 42.1 V 9.27 A Opt. Operating Voltage (Vmp) Opt. Operating Current (Imp) Open Circuit Voltage (Voc) Short Circuit Current (Isc) 2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. CANADIAN SOLAR (USA), INC. July 2021 | All rights reserved | PV Module Datasheet v2.7J25_F30_J3_NA 625 W Columbine Ave - Rev #2017748409/28/22 MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3) Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box (4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice. 625 W Columbine Ave09/19/22 IN V E R T E R S solaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR WARRANTY 625 W Columbine Ave - Rev #2017748409/28/22 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents Rapid shutdown cables Micro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals. Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. DC connection terminals Disconnect here Disconnect here Switch terminal block Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): If the cables at the top are red and black from left to right, connect as shown below. Figure 2: Rapid shutdown cable connected option 1 If the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected option 2 6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. Red (+) Black (-) Black (-) DC+ DC- Red (+) with rapid shutdown resistor Black (-) Red (+) Black (-) BlaRed (+) with rapid shutdown resistor DC+ DC- 625 W Columbine Ave09/19/22 MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)----Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Single Phase Inverter with HD-Wave Technology for North America 625 W Columbine Ave - Rev #2017748409/28/22 SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICE With Superior Aesthetics CONCEALED UNIVERSAL CLAMPS 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISI T UNIRAC.COM OR CALL (505) 248-2702 625 W Columbine Ave09/19/22 MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3) Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box (4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice. 625 W Columbine Ave - Rev #2017748409/28/22 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year limited product warranty and a 5 year limited finish warranty. TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2008, 14001:2004 and OHSAS 18001:2007, which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices. UL2703BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONL I S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR Q UE S TI ON S OR C US TOME R S E R VI C E VI S I T UN I R A C . C OM OR C A LL (5 0 5 ) 2 48 -2 7 0 2PUB2018AUG31 – PRINTED UPDATE 625 W Columbine Ave09/19/22 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents Rapid shutdown cables Micro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals. Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. DC connection terminals Disconnect here Disconnect here Switch terminal block Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): If the cables at the top are red and black from left to right, connect as shown below. Figure 2: Rapid shutdown cable connected option 1 If the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected option 2 6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. Red (+) Black (-) Black (-) DC+ DC- Red (+) with rapid shutdown resistor Black (-) Red (+) Black (-) BlaRed (+) with rapid shutdown resistor DC+ DC- 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 OWNER James Wessinger PHONE: 1714-308-6363 EMAIL: jweissinger072@gmail.com CONTRACTOR: BETTER EARTH ELECTRIC INC. PHONE: (888) 373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: Santa Ana (CA) UTILITY: Southern California Edison DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH ROOF SURFACE: 1822 SQ.FT. PV SQ FOOTAGE: 676 SQ.FT. PV COVERAGE: 37.10 % WEIGHT OF EQUIPMENT: 15268 NO. OF STORIES: 1 FIRE SPRINKLERS: NO LOT INFORMATION APN: 41019306 LOT AREA: 8330 LIVING AREA: 1822 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Meris Smajiic NE W P V S Y S T E M : 1 2 4 8 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 9. 19. 2022 9. 19. 2022 DATE: TIME: 05:09 AM 05:09 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. PROPERTY INFORMATION James Wessinger 625 W Columbine Ave, Santa Ana, CA 92707 APN: 41019306 SYSTEM SIZE: 12,480 DC SYSTEM SIZE 10,000 AC CEC POWER OUTPUT: 11648 CEC MODULE INFORMATION MODULE QTY: 32 MODULE MFG: Canadian MODULE TYPE: Canadian CS3N-390MS INVERTER INFORMATION INVERTER QTY: 1 INVERTER MFG: SOLAREDGE INVERTER TYPE: 10000H-US Non-RGM POWER OPTIMIZER INFORMATION OPTIMIZER QTY: 32 OPTIMIZER MFG: SOLAREDGE OPTIMIZER TYPE: S440 PROJECT DETAILS COVER SHEET P1 TABLE OF CONTENTS PAGE NUMBER: PAGE TITLE: P1 COVER SHEET P2 SITE PLAN P3 ROOF PLAN P4 RACKING & FRAMING P5 LINE DIAGRAM & DESIGN TABLES P6 PLACARDS & PLACARD MAP P7 OPTIMIZER MAP P8 JOB HAZARD ANALYSIS P9 ELEC. LOAD CALCS SS00 SPECIFICATION PAGES RAILING INFORMATION RAILING MFG: UNIRAC RAILING TYPE: Unirac SM Light MOUNTING INFORMATION MOUNT FLASHING QTY: 68 MOUNT FLASHING MFG: UNIRAC MOUNT FLASHING TYPE: Unirac Flashloc-RM EXISTING SOLAR INFORMATION INVERTER QTY: N/A INVERTER MFG & TYPE : N/A MODULE QTY: N/A MODULE MFG & TYPE: N/A BATTERY INFORMATION BATTERY QTY: N/A BATTERY MFG: N/A BATTERY TYPE: N/A 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2019 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2019 CALIFORNIA ELECTRICAL CODE AND 2019 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). GENERAL NOTES · 2019 CALIFORNIA BUILDING CODE · 2019 CALIFORNIA RESIDENTIAL CODE · 2019 CALIFORNIA ELECTRICAL CODE · 2019 CALIFORNIA FIRE CODE · 2019 CALIFORNIA MECHANICAL CODE · 2019 CALIFORNIA GREEN CODE · 2019 CALIFORNIA PLUMBING CODE · 2019 CALIFORNIA ENERGY CODE · ANY OTHER LOCAL AND MUNICIPAL CODES CODE REFERENCES ADDITIONAL SCOPE OF WORK Bldg permit #101112153 Elect permit #20177484 Revision permits issued 9/28/22 625 W Columbine Ave - Rev #2017748409/28/22 Power Optimizer For Residential Installations S440, S500, S500B 25 YEAR WARRANTY Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules * Functionality subject to inverter model and firmware version solaredge.com PO W E R OP T I M I Z E R 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 OWNER James Wessinger PHONE: 1714-308-6363 EMAIL: jweissinger072@gmail.com CONTRACTOR: BETTER EARTH ELECTRIC INC. PHONE: (888) 373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: Santa Ana (CA) UTILITY: Southern California Edison DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH ROOF SURFACE: 1822 SQ.FT. PV SQ FOOTAGE: 656 SQ.FT. PV COVERAGE: 36 % WEIGHT OF EQUIPMENT: 1621.46 NO. OF STORIES: 1 FIRE SPRINKLERS: NO LOT INFORMATION APN: 41019306 LOT AREA: 8330 LIVING AREA: 1822 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 08:38 PM 08:38 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. PROPERTY INFORMATION James Wessinger 625 W Columbine Ave, Santa Ana, CA 92707 APN: 41019306 SYSTEM SIZE: 12,240 DC SYSTEM SIZE 10,000 AC CEC POWER OUTPUT: 11288 CEC MODULE INFORMATION MODULE QTY: 34 MODULE MFG: Hanwha Q CELLS MODULE TYPE: Q.Peak Duo BLK-G10+ 360 INVERTER INFORMATION INVERTER QTY: 1 INVERTER MFG: SOLAREDGE INVERTER TYPE: 10000H-US Non-RGM POWER OPTIMIZER INFORMATION OPTIMIZER QTY: 34 OPTIMIZER MFG: SOLAREDGE OPTIMIZER TYPE: S440 PROJECT DETAILS COVER SHEET P1 TABLE OF CONTENTS PAGE NUMBER: PAGE TITLE: P1 COVER SHEET P2 SITE PLAN P3 ROOF PLAN P4 RACKING & FRAMING P5 LINE DIAGRAM & DESIGN TABLES P6 PLACARDS & PLACARD MAP P7 OPTIMIZER MAP P8 JOB HAZARD ANALYSIS P9 ELEC. LOAD CALCS SS00 SPECIFICATION PAGES RAILING INFORMATION RAILING MFG: UNIRAC RAILING TYPE: Unirac SM Light MOUNTING INFORMATION MOUNT FLASHING QTY: 60 MOUNT FLASHING MFG: UNIRAC MOUNT FLASHING TYPE: Unirac Flashloc-RM EXISTING SOLAR INFORMATION INVERTER QTY: N/A INVERTER MFG & TYPE : N/A MODULE QTY: N/A MODULE MFG & TYPE: N/A BATTERY INFORMATION BATTERY QTY: N/A BATTERY MFG: N/A BATTERY TYPE: N/A 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2019 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2019 CALIFORNIA ELECTRICAL CODE AND 2019 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). GENERAL NOTES · 2019 CALIFORNIA BUILDING CODE · 2019 CALIFORNIA RESIDENTIAL CODE · 2019 CALIFORNIA ELECTRICAL CODE · 2019 CALIFORNIA FIRE CODE · 2019 CALIFORNIA MECHANICAL CODE · 2019 CALIFORNIA GREEN CODE · 2019 CALIFORNIA PLUMBING CODE · 2019 CALIFORNIA ENERGY CODE · ANY OTHER LOCAL AND MUNICIPAL CODES CODE REFERENCES ADDITIONAL SCOPE OF WORK BLDG # 101111889 ELEC # 20177290 ISSUED: 9/17/2022 625 W Columbine Ave09/19/22 Power Optimizer For Residential Installations S440, S500, S500B S440 S500 S500B UNIT Rated Input DC Power(1)440 500 W Absolute Maximum Input Voltage (Voc)60 125 Vdc MPPT Operating Range 8 - 60 12.5 - 105 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 +/- 0.1 Vdc STANDARD COMPLIANCE EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H)129 x 155 x 30 129 x 155 x 45 mm Weight (including cables)655 gr Input Connector MC4(2) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(3)-40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 - 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For other connector types please contact SolarEdge. (3) For ambient temperature above +70°C power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(4) Single Phase HD-Wave Three Phase SExxK-RWB Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B 6 8 14 Maximum String Length (Power Optimizers 25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(5)See(5)13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (4) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (5) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the invert ers maximum input DC power. Refer to https://www.solaredge.com/sites/default/files/se-power-optimizer-single-string-design-application-note.pdf. *45mm for S500B © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: June 15, 2022 DS-000091-ENG. Subject to change without notice. 625 W Columbine Ave - Rev #2017748409/28/22 SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICE With Superior Aesthetics CONCEALED UNIVERSAL CLAMPS 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISI T UNIRAC.COM OR CALL (505) 248-2702 625 W Columbine Ave - Rev #2017748409/28/22 Digitally sealed by RJM on Date: Job #: Jurupa Valley, CA 92509 Email: SE@mcpe.group 8/18/22 8/18/22 22-11941 Mobile: (909) 566-0066 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Wessinger Residence 625 W Columbine Ave. Santa Ana, CA 92707 Designed in Accordance with CBC 2019, ASCE 7-16, NDS 2018 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave 8/18/2022 10:58 AM 1 of 7 ©McPherson Engineering 625 W Columbine Ave09/19/22 McPherson Engineering By: M.M. Date: 8/18/22 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents 8/18/2022 10:58 AM 2 of 7 ©McPherson Engineering 625 W Columbine Ave09/19/22 McPherson Engineering By: M.M. Date: 8/18/22 Location: 625 W Columbine Ave. Santa Ana, CA 92707 Existing Structure Info: Number of Stories = 1 Aroof = 1800 sq. ft. Roof Square Footage A3rd_flr = 0 sq. ft. Third Floor Square Footage (if applicable) A2nd_flr = 0 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Lattitude = Longitude = Ss = 1.279 S1 = 0.459 Exposure Category = C Ult. Wind Speed = 110 m.p.h. P.V. Array Info: Model = HANWHA Q.PEAK DUO BLK-G10+/AC 360W Height of Panel = 67.60 in. Width of Panel = 41.10 in. Area of Panel = 19.3 ft.2 Number of New Panels = 34 Number of Exis. Panels = 0 Total Area of Array = 656.0 ft.2 Spacing of Anchors = 4.0 ft. max. on center rows of racks per panel = 2 Panel Tilt = 7-27 deg Project Info 33.703134 -117.876128 8/18/2022 10:58 AM 3 of 7 ©McPherson Engineering 625 W Columbine Ave09/19/22 McPherson Engineering By: M.M. Date: 8/18/22 Existing Loads: Roof Design Loads: Roofing = 4.0 p.s.f.Composition roofing Sheathing = 1.5 p.s.f.1/2" Plywood Framing = 1.5 p.s.f.2x Rafter/Truss Framing Misc = 1.0 p.s.f. DLr1 = 8.0 p.s.f.Roofing Dead Load (applied to top of rafters/trusses only) Ceiling = 2.0 p.s.f. Drywall and 2x framing DLr2 = 10.0 p.s.f. Total Existing Roof Dead Load LLr = 20.0 p.s.f. Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing = 2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions = 15.0 p.s.f.2x framed walls with drywall finish each side Ceiling = 5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load L = 182.0 Total length of walls Proposed Loads: Panels = 2.9 p.s.f. weight of panels including rack system DLr1_proposed = 10.9 p.s.f. Proposed Roof Dead Load (applied to top only) DLr2_proposed = 12.9 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) = 50.4 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) = 39.2 kips Proposed Load Demand Wprop - Wex = -22.26% Wex TOTAL DECREASE IN GRAVITY LOADS, PANELS OK! Roof Live Loads need not be applied to the area covered with by PV panel where the clear space between the panels and the roof sureface is 24in or less, 1607.13.5.1 item 1 Exception Gravity Loads 8/18/2022 10:58 AM 4 of 7 ©McPherson Engineering 625 W Columbine Ave09/19/22 McPherson Engineering By: M.M. Date: 8/18/22 Seismic Design Parameters Risk Category = 2 Per Table 1-5-1 R = 6.5 Response Modification Factor (Table 12-2.1) Site Class = D Per 11.4.2 Ie = 1 Seismic Importance Factor (Table 1.5-2) Ss = 1.28 Short Period P.G.A. S1 = 0.46 1-Sec Period P.G.A. S.D.C. = D Seismic Design Category Per 11.6 Fa = 1.20 Site Coefficient per Table 11.4-1 ASCE 7-16 Supplement #1 Tables used for Fa and Fv Fv = 1.70 Site Coefficient per Table 11.4-2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa = 1.53 Short Period M.C.E. Per Eq. 11.4-1 SM1 = SD1 Fv = 0.78 1-Sec Period M.C.E. Per Eq. 11.4-2 SDS = 2/3 (SMS) = 1.02 Short Period Design Parameter Per Eq 11.4-3 SD1 = 2/3 (SM1) = 0.52 1-Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) per Eq. 12.8-7 hn = 15 ft Ct = 0.02 (per table 12.8-2) x = 0.75 (per table 12.8-2) T = 0.15 sec Approximate Fundamental Period TL = 8 sec Long-Period Transition Period per Figure 22-12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.16 Seismic Response Coefficient Per Eq. 12.8-2 Cs1 = 1.5*(SD1 Ie)/R T = 0.79 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T ≤ TL Cs2 = 0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs2 = 0.044 SDS Ie = 0.05 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs3 = 0.5 S1 Ie/R = 0.04 Min. Seismic Response Coefficient Per Eq. 12.8-6 if S 1 ≥ 0.6g CS = 0.16 Design Seismic Coefficient Check Additional Base Shear Wexisting = 28.9 kips Weight of Existing Structure Wpanels = 1.9 kips Weight of Proposed Panels Vexisting = Cs Wexisting = 4.6 kips Roof Level Shear of Existing Structure Vpanels = Cs Wpanels = 0.3 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn) x = 6.58% < 10%PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 8/18/2022 10:58 AM 5 of 7 ©McPherson Engineering 625 W Columbine Ave09/19/22 McPherson Engineering By: M.M. Date: 8/18/22 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7-16) Vult = 110 mph Kzt = 1.00 (sec 26.8.2) h = 15 ft Exposure Category = C Kz = 0.85 (sec 26.10.1) Roof Zone = 2 Kd = 0.85 (sec 26.6) Roof θ = 7-27 deg Ke = 1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V 2 qh = 22.38 (eq. 26.10-1) GPp = -2 uplift γE = 1.5 (sec 29.4.4) γa = 0.78 (fig 29.4-8) γE = 1.5 FIG 29.4-7)γc = 0.94 (fig 29.4-7) hpt = 0 γa = 0.78 (fig 29.4-8)γ p = 0.9 (fig 29.4-7)ω = 0.00 deg (panel tilt) GPp = -2 uplift GCrm = 1.4 uplift p = qh (GPp) γ E γa (eq 29.4-7) p = qh (GCrn) γ E γC γp (eq 29.4-6) p = -52.3 p.s.f.p = 39.7 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W controlling load combination (eq. 16-15 for ASD) DL = 2.9 p.s.f.dead load of panel (inlcuding rack system) W = 52.3 p.s.f.wind load normal to face of panel Arealag = 11.3 sq. ft.area tributary to each anchor SPanc = 4.0 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) = 334.1 lbs total uplift on anchor Material = DFL lumber anchor material Dialag = 5/16 in. diameter of screw Penlag = 2.5 in. min. penetration to existing framing Wlag = 266 lb/in. withdrawal load per in. of penetration per NDS Table 11.2A CD = 1.6 load duration factor for wind per NDS Table 2.3.2 Ct = 0.8 temperature factor per NDS Table 2.3.3 Noscrews = 1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews = 851.2 lbs total allowable withrawal on anchor Puplift Pallow Anchorage = USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION 0.39 < 1.00 Anchor is OK! Wind Uplift Anchorage = Flush Mounted Panels - ASCE Section 29.4.4 (where applicable) Flat Roof Panels - ASCE Section 29.4.3 (where applicable) 8/18/2022 10:58 AM 6 of 7 ©McPherson Engineering 625 W Columbine Ave09/19/22 McPherson Engineering By: M.M. Date: 8/18/22 Gravity Loads: DEMAND DECREASED BY 22.26% = OK! Lateral Loads: DEMAND INCREASED BY 6.58% < 10% = OK! Anchorage: DEMAND OF 334.1LB. < CAPACITY OF 851.2LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRAY ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 8/18/2022 10:58 AM 7 of 7 ©McPherson Engineering 625 W Columbine Ave09/19/22 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year limited product warranty and a 5 year limited finish warranty. TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2008, 14001:2004 and OHSAS 18001:2007, which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices. UL2703BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONL I S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR Q UE S TI ON S OR C US TOME R S E R VI C E VI S I T UN I R A C . C OM OR C A LL (5 0 5 ) 2 48 -2 7 0 2PUB2018AUG31 – PRINTED UPDATE 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 MM INV MM INV SCALE: Custom SITE PLAN N (E) 200A MAIN SERVICE PANEL (N) SOLAREDGE 10000H-US Non-RGM INVERTER ROOF ACCESS POINT PER CRC 2019 (R324.7.1) 1) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4) THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5) A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA REGULATIONS. 6) MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7) ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8) CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. SITE PLAN P2 (E) DRIVEWAY (E) PROPERTY LINE Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Meris Smajiic NE W P V S Y S T E M : 1 2 4 8 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 9. 19. 2022 9. 19. 2022 DATE: TIME: 05:09 AM 05:09 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. CONSTRUCTION NOTES FIRE CODE PATHWAY COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PRODUCTION METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC LOAD CENTER INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4 " EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX LEGEND CALLOUTS PROPERTY LINE INSTALLER NOTES ARRAY 1 - (N) 32 Canadian MODULES TILT: 23° AZIMUTH: 341° 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 MM INV JB MM INV JB SCALE: Custom SITE PLAN N (E) 200A MAIN SERVICE PANEL (N) SOLAREDGE 10000H-US Non-RGM INVERTER 1) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4) THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5) A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA REGULATIONS. 6) MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7) ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8) CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. SITE PLAN P2 (E) DRIVEWAY (E) PROPERTY LINE Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 08:38 PM 08:38 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. CONSTRUCTION NOTES FIRE CODE PATHWAY COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PRODUCTION METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC LOAD CENTER INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4 " EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX LEGEND CALLOUTS PROPERTY LINE INSTALLER NOTESARRAY 1 - (N) 34 Hanwha Q CELLS MODULES TILT: 23° AZIMUTH: 341° 625 W Columbine Ave09/19/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 MM INV Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Meris Smajiic NE W P V S Y S T E M : 1 2 4 8 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 9. 19. 2022 9. 19. 2022 DATE: TIME: 05:09 AM 05:09 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. SCALE: 3/32" = 1' FIRE CODE PATHWAY N ARRAY 1: MODULE QTY: 32 TILT: 23° AZIMUTH: 341° MATERIAL: Comp Asphalt Shingles COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PV METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC COMBINER PANEL INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4" EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX ROOF PLAN ROOF PLAN P3 ROOF DETAILS:LEGEND CALLOUTS: INSTALLER NOTES 48'-2" 14 ' -7" 20'-6" 13'-8" REQUIRED ROOF ACCESS POINT PER CRC 2019 SECTION R324. LADDER ACCESS SHALL BE AT STRONG POINT OF ROOF AND NOT OVER REQUIRED WINDOW OPENINGS. JB 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 MM INV JB Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 08:38 PM 08:38 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. SCALE: 3/32" = 1' FIRE CODE PATHWAY N ARRAY 1: MODULE QTY: 34 TILT: 23° AZIMUTH: 341° MATERIAL: Comp Asphalt Shingles COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PV METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC COMBINER PANEL INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4" EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX ROOF PLAN ROOF PLAN P3 ROOF DETAILS:LEGEND CALLOUTS: INSTALLER NOTES 51'-7" 10'-3" 23'-11" 11 ' -3 " 11 ' -2 " 20'-6" 10'-3" REQUIRED ROOF ACCESS POINT PER CRC 2019 SECTION R324. LADDER ACCESS SHALL BE AT STRONG POINT OF ROOF AND NOT OVER REQUIRED WINDOW OPENINGS. 625 W Columbine Ave09/19/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE Comp Asphalt Shingles 48" 2x6 RAFTERS @24"" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT AND FLASHING E 2x6 RAFTER TYPICAL SOL A R MOD U L E S Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Meris Smajiic NE W P V S Y S T E M : 1 2 4 8 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 9. 19. 2022 9. 19. 2022 DATE: TIME: 05:09 AM 05:09 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. RACKING & FRAMING DETAILS P4 TYPICAL ROOF ATTACHMENT PLAN ATTACHMENT DETAIL FRONT VIEW TYP FRAMING DETAIL 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE Comp Asphalt Shingles 48" 2x6 RAFTERS @24"" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT AND FLASHING E 2x6 RAFTER TYPICAL SOL A R MOD U L E S Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 08:38 PM 08:38 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. RACKING & FRAMING DETAILS P4 TYPICAL ROOF ATTACHMENT PLAN ATTACHMENT DETAIL FRONT VIEW TYP FRAMING DETAIL 625 W Columbine Ave09/19/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 (E) GROUNDING ELECTRODE GROUND ROD STRING 1: (16x) Canadian Canadian CS3N-390MS PV MODULES WITH 16 S440 SE POWER OPTIMIZERS 01 01 JUNCTION BOX - NEMA 3R AS REQUIRED 2A INVERTER SOLAREDGE 10000H-US NON-RGM WITH DC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 3A+ - + - + - + - + - + - + - + - + - + - + - + - STRING 2: (16x) Canadian Canadian CS3N-390MS PV MODULES WITH 16 S440 SE POWER OPTIMIZERS 1621 1621 DC AC TO UTILITY GRID (Underground) MAX. BREAKER CALC.: 200A X 1.2 - (N) 60A MA I N ( N ) 17 5 A POINT OF INTERCONNECTION LOAD SIDE 705.12(D)(2)(3)(B) 175A = 65A M BI-DIRECTIONAL UTILITY METER 1PH/240V (E) 200A/175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUS BAR FROM THE MAIN BREAKER (N)DERATED MAIN BREAKER CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 1 #10 PV Wire, in open air FREE AIR N/A N/A #6 51 1 15 18.75 40 38.4 90 50 2 #10 THWN-2, in conduit 3/4" EMT 2 N/A #8 51 1 15 18.75 40 38.4 75 35 3 #6 THWN-2, in conduit 3/4" EMT 3 60 #8 32 1 42 53 75 72 75 50 4 5 6 7 ASHRAE EXTREME LOW DESIGN TEMPERATURES ASHRAE 2% HIGH 32 32 POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS SYSTEM SUMMARY ARRAY STC POWER 12480W ARRAY PTC POWER 11648W MAX AC CURRENT 60A MAX AC POWER 10000W INVERTER 1 STRING 1 STRING 2 15A 16 380V 42A 15A 16 380V 42A POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY SOLAREDGE S440 Optimizer MAX OUTPUT(A) MAX DC (V) INVERTER 1 SPECS SOLAREDGE 10000H-US_Non-RGM AC VOLTAGE (V) 240 GROUND 0.99 MAX OCPD (A) 60 RATED POWER (W) 10000 MAX OUTPUT (A) 42 MAX INPUT (A) 27 MAX INPUT (V) 480 EFFICIENCY (CEC) 0.99 MODULE SPECS Canadian Canadian CS3N-390MS PMAX (W) 390 PTC (W) 364.3 ISC (A) 11.38 IMP (A) 10.6 VOC (V) 44.1 VMP (V) 36.8 TEMP. COEFF. OF VOC -0.122 440 15 98.6 15 60 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Meris Smajiic NE W P V S Y S T E M : 1 2 4 8 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 9. 19. 2022 9. 19. 2022 DATE: TIME: 05:09 AM 05:09 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELECTRICAL NOTES 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ALL WORK SHALL COMPLY WITH THE 2019 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. ELECTRICAL LINE DIAGRAM LINE DIAGRAM & DESIGN TABLES P5 DESIGN TABLES 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 (E) GROUNDING ELECTRODE GROUND ROD STRING 1: (11x) Hanwha Q CELLS Q.Peak Duo BLK-G10+ 360 PV MODULES WITH 11 S440 SE POWER OPTIMIZERS 01 01 01 JUNCTION BOX - NEMA 3R AS REQUIRED 2A INVERTER SOLAREDGE 10000H-US NON-RGM WITH DC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 3A+ - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - + - STRING 2: (11x) Hanwha Q CELLS Q.Peak Duo BLK-G10+ 360 PV MODULES WITH 11 S440 SE POWER OPTIMIZERS STRING 3: (12x) Hanwha Q CELLS Q.Peak Duo BLK-G10+ 360 PV MODULES WITH 12 S440 SE POWER OPTIMIZERS 1221 1121 1121 DC AC TO UTILITY GRID (Underground) MAX. BREAKER CALC.: 200A X 1.2 - (N) 60A MA I N ( N ) 17 5 A POINT OF INTERCONNECTION LOAD SIDE 705.12(D)(2)(3)(B) 175A = 65A M BI-DIRECTIONAL UTILITY METER 1PH/240V (E) 200A/175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUS BAR FROM THE MAIN BREAKER (N)DERATED MAIN BREAKER CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 1 #10 PV Wire, in open air FREE AIR N/A N/A #6 51 1 15 18.75 40 38.4 90 50 2 #10 THWN-2, in conduit 3/4" EMT 2 N/A #8 51 1 15 18.75 40 38.4 75 35 3 #6 THWN-2, in conduit 3/4" EMT 3 60 #8 32 1 42 53 75 72 75 50 4 5 6 7 ASHRAE EXTREME LOW DESIGN TEMPERATURES ASHRAE 2% HIGH 32 32 POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS SYSTEM SUMMARY ARRAY STC POWER 12240W ARRAY PTC POWER 11288W MAX AC CURRENT 60A MAX AC POWER 10000W INVERTER 1 STRING 1 STRING 2 STRING 3 15A 12 380V 42A 15A 11 380V 42A 15A 11 380V 42A POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY SOLAREDGE S440 Optimizer MAX OUTPUT(A) MAX DC (V) INVERTER 1 SPECS SOLAREDGE 10000H-US_Non-RGM AC VOLTAGE (V) 240 GROUND 0.99 MAX OCPD (A) 60 RATED POWER (W) 10000 MAX OUTPUT (A) 42 MAX INPUT (A) 27 MAX INPUT (V) 480 EFFICIENCY (CEC) 0.99 MODULE SPECS Hanwha Q CELLS Q.Peak Duo BLK-G10+ 360 PMAX (W) 360 PTC (W) 332 ISC (A) 11 IMP (A) 10 VOC (V) 41 VMP (V) 34 TEMP. COEFF. OF VOC -0.122 440 15 98.6 15 60 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 08:38 PM 08:38 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELECTRICAL NOTES 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ALL WORK SHALL COMPLY WITH THE 2019 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. ELECTRICAL LINE DIAGRAM LINE DIAGRAM & DESIGN TABLES P5 DESIGN TABLES 625 W Columbine Ave09/19/22 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION SERVICE BY QUALIFIED PERSONNEL ONLY N Nathan Draeger REV: DESCRIPTION: BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Meris Smajiic NE W P V S Y S T E M : 1 2 4 8 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 9. 19. 2022 9. 19. 2022 DATE: TIME: 05:09 AM 05:09 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ROOFTOP PV ARRAY UTILITY METER AND MAIN SERVICE PANEL INVERTER YOU ARE HERE PLACARD & PLACARD MAP P6 LABELING PLAN LABEL DIRECTORY 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2. MINIMUM 3/8 INCHES LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT (NON-BOLD) MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS PROPERTY MAP PROPERTY MAP NOTES: BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 STICKER LOCATED INSIDE PANEL NEXT TO PV BREAKER 11 [CEC 690.14(C)(2)] PLACE ON AC DISCONNECT 8 9 [CEC 705.12(B)(2)(3)(C)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. PHOTOVOLTAIC SOLAR BREAKER PHOTOVOLTAIC AC DISCONNECT ! WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 2 3 [CEC 690.53] AT EACH DC DISCONNECT MEANS [CEC 690.5(C)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 [CEC 690.31(G)3 & 4] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' WARNING: PHOTOVOLTAIC POWER SOURCE ! MAXIMUM VOLTAGE PHOTOVOLTAIC SYSTEM DC DISCONNECT ! MAX CIRCUIT CURRENT 15 AMPS ! TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD WARNING MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-DC CONVERTER 4 [CEC 690.12(5)] PLACE ON INVERTER PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 7 6 5 [CEC 690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) [CEC 690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES CEC 705.12(B)(2)(3)(B) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) ! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY WARNING ! RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT ! ! DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONNECTION WARNING 42A 480 VDC 27 AMPS SUB PANEL 5 6 JUNCTION BOX METER MAIN SERVICE PANEL 1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 7 3 5 8 3 5 8 3 5 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE 625 W Columbine Ave - Rev #2017748409/28/22 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION SERVICE BY QUALIFIED PERSONNEL ONLY N Nathan Draeger REV: DESCRIPTION: BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 08:38 PM 08:38 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ROOFTOP PV ARRAY UTILITY METER AND MAIN SERVICE PANEL INVERTER YOU ARE HERE PLACARD & PLACARD MAP P6 LABELING PLAN LABEL DIRECTORY 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2. MINIMUM 3/8 INCHES LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT (NON-BOLD) MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS PROPERTY MAP PROPERTY MAP NOTES: BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 STICKER LOCATED INSIDE PANEL NEXT TO PV BREAKER 11 [CEC 690.14(C)(2)] PLACE ON AC DISCONNECT 8 9 [CEC 705.12(B)(2)(3)(C)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. PHOTOVOLTAIC SOLAR BREAKER PHOTOVOLTAIC AC DISCONNECT ! WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 2 3 [CEC 690.53] AT EACH DC DISCONNECT MEANS [CEC 690.5(C)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 [CEC 690.31(G)3 & 4] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' WARNING: PHOTOVOLTAIC POWER SOURCE ! MAXIMUM VOLTAGE PHOTOVOLTAIC SYSTEM DC DISCONNECT ! MAX CIRCUIT CURRENT 15 AMPS ! TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD WARNING MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-DC CONVERTER 4 [CEC 690.12(5)] PLACE ON INVERTER PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 7 6 5 [CEC 690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) [CEC 690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES CEC 705.12(B)(2)(3)(B) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) ! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY WARNING ! RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT ! ! DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONNECTION WARNING 42A 480 VDC 27 AMPS SUB PANEL 5 6 JUNCTION BOX METER MAIN SERVICE PANEL 1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 7 3 5 8 3 5 8 3 5 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE 625 W Columbine Ave09/19/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Meris Smajiic NE W P V S Y S T E M : 1 2 4 8 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 9. 19. 2022 9. 19. 2022 DATE: TIME: 05:09 AM 05:09 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 42 34 43 35 44 36 45 37 46 38 47 39 48 40 49 41 50 OPTIMIZER MAP P7 SYSTEM SIZE 12480 W DC MODULE TYPE Canadian Canadian CS3N-390MS MODULE QTY 32 INVERTER TYPE SOLAREDGE 10000H-US Non-RGM INVERTER INVERTER QTY 1 POWER OPTIMIZER TYPE SOLAREDGE S440 POWER OPTIMIZER POWER OPTIMIZER QTY 32 SYSTEM DETAILS 52 53 54 56 57 58 60 61 62 64 65 66 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 51 55 59 63 67 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 08:38 PM 08:38 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 42 34 43 35 44 36 45 37 46 38 47 39 48 40 49 41 50 OPTIMIZER MAP P7 SYSTEM SIZE 12240 W DC MODULE TYPE Hanwha Q CELLS Q.Peak Duo BLK-G10+ 360 MODULE QTY 34 INVERTER TYPE SOLAREDGE 10000H-US Non-RGM INVERTER INVERTER QTY 1 POWER OPTIMIZER TYPE SOLAREDGE S440 POWER OPTIMIZER POWER OPTIMIZER QTY 34 SYSTEM DETAILS 52 53 54 56 57 58 60 61 62 64 65 66 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 51 55 59 63 67 625 W Columbine Ave09/19/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 H HAZARD A ANCHOR POINT LEGEND L LADDER E ENTRY / EXIT WORK ANGLE ELECTRICAL ZONE WORK ZONE JOB HAZARD ANALYSIS Use the space below to draft a JHA. Be sure to include all indicators found in the Legend. (E) DRI VEWA Y NEAREST MEDICAL FACILITY: JOB HAZARD ANALYSIS P8 Nathan Draeger DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: Meris Smajiic NE W P V S Y S T E M : 1 2 4 8 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 6 2 5 W C o l u m b i n e Av e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 9. 19. 2022 9. 19. 2022 DATE: TIME: 05:09 AM 05:09 AM CREW LEAD: CREW: NAME: PHONE: ADDRESS: (E) ENTRANCE 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 H HAZARD A ANCHOR POINT LEGEND L LADDER E ENTRY / EXIT WORK ANGLE ELECTRICAL ZONE WORK ZONE JOB HAZARD ANALYSIS Use the space below to draft a JHA. Be sure to include all indicators found in the Legend. NEAREST MEDICAL FACILITY: JOB HAZARD ANALYSIS P8 Nathan Draeger DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 6 2 5 W C o l u m b i n e Av e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 08:38 PM 08:38 PM CREW LEAD: CREW: NAME: PHONE: ADDRESS: (E) ENTRANCE 625 W Columbine Ave09/19/22 Date: 8/17/2022 Single Family Dwelling Electrical Service Load Calculation 1. General Lighting Loads Dwelling 1822 sq. ft X 3 VA =5466 VA Small appliance loads -220-16(a) 1500 VA X 2 Circuits = 3000 VA Laundry load - 220-16 (b) 1500 VA X 1 Circuits = 1500 VA General Lighting Total 9,966 VA 2. Cooking Equipment Loads - Nameplate Value Range 0 Amps =0 VA Cooktop Amps =0 VA Oven Amps =0 VA Cooking Equipment Total 0 VA 3. Electric Dryer 220-18 (Nameplate, 5000 VA minimum) Dryer qty: 0 VA Dryer Total 0 VA 4. Other Loads Subpanel @ Amps X 240 Volts =0 VA Garbage @ 20 Amps X 120 Volts =2400 VA Dishwasher @ 20 Amps X 120 Volts =2400 VA Microwave @ 20 Amps X 120 Volts =2400 VA AC @ 30 Amps X 240 Volts =7200 VA pool @ 20 Amps X 120 Volts =2400 VA Washer @ 20 Amps X 120 Volts =2400 VA Fridge @ 20 Amps X 120 Volts =2400 VA Freezer @ 30 Amps X 120 Volts =3600 VA lights @ 75 Amps X 120 Volts =9000 VA @ Amps X 120 Volts =0 VA Fixed Appliance Total 34,200 VA 5. Subtotal (add all above lines) 44,166 VA 6. First 10,000 VA X 100%10,000 VA Remaining 34,166 VA X 40% =13,666 VA 7. Total Load 23,666 VA 10. Existing Minimum Service Size = Total Load in VA =98.61 Amps 625 W Columbine Ave - Rev #2017748409/28/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 .\BRYSON Capture.PNG .\ b e t t e r - e a r t h - l o g o - f d 1 7 b d e 4 . p n g Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 05:41 PM 05:41 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELEC LOAD CALCS P9 ELECTRICAL LOAD CALCULATIONS 625 W Columbine Ave09/19/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 .\BRYSON Capture.PNG .\ b e t t e r - e a r t h - l o g o - f d 1 7 b d e 4 . p n g Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Candace Colletta NE W P V S Y S T E M : 1 2 2 4 0 D C / 1 0 . 0 0 0 A C J a m e s W e s s i n g e r 62 5 W C o l u m b i n e A v e , S a n t a A n a , C A 92 7 0 7 AP N : 4 1 0 1 9 3 0 6 8/17/2022 8/17/2022 DATE: TIME: 05:41 PM 05:41 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELEC LOAD CALCS P9 ELECTRICAL LOAD CALCULATIONS 625 W Columbine Ave09/19/22