HomeMy WebLinkAbout901 N Westwood Ave - PlanBLDG# 101111905 ISS. 3/29/23 ELEC# 20177306 ISS. 3/29/23 BLDG P/C J.Lo, ELEC P/C M. Smith The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 901 N Westwood Ave - 101111905-2017730 6 03/29/23 901 N Westwood Ave - 101111905-201773 06 03/29/23 901 N Westwood Ave - 101111905-201773 06 03/29/23 901 N Westwood Ave - 101111905-201773 06 03/29/23 901 N Westwood Ave - 101111905-201773 06 03/29/23 901 N Westwood Ave - 101111905-201773 06 03/29/23 901 N Westwood Ave - 101111905-201773 06 03/29/23 U-BUILDER PROJECT REPORT VERSION: 3.1.6 PROJECT TITLE SOLARMOUNT FLUSH PROJECT ID A2B79A24 CREATED June 3, 2022, 3:18 p.m. NAME ADDRESS 901 N Westwood Ave, Santa Ana, CA 92703, USA CITY, STATE Santa Ana, CA MODULE Trina Solar TSM-DD06M.05(II) 330 Designed by mason.mpwrsolar@gmail.com SOLARMOUNT FLUSH Trina Solar 9 - TSM-DD06M.05(II) 330 165.16 ft 2.97 KW 2 901 N Westwood Ave - 101111905-201773 06 03/29/23 ENGINEERING REPORT * Distributed Dead Load 2.77 psf * Average Roof Point Dead Load 16.33 lbs 92703 Plan review TOTAL NUMBER OF MODULES 9 TOTAL KW 2.97 KW TOTAL MODULE AREA ~165 ft Loads Used for Design BUILDING CODE ASCE 7-16 BASIC WIND SPEED 100.00 mph GROUND SNOW LOAD 0.00 psf SEISMIC (SS)1.462 ELEVATION 81.00 ft WIND EXPOSURE B TOPOGRAPHICAL FACTOR KZT 1.00 VELOCITY PRESSURE, QZ 15.20 psf Loads Determined by Zip CITY, STATE Santa Ana, CA BASIC WIND SPEED 89.00 mph GROUND SNOW LOAD 0.00 psf 2 Inspection PRODUCT SOLARMOUNT FLUSH MODULE MANUFACTURER Trina Solar MODEL 9 - TSM-DD06M.05(II) 330 MODULE WATTS 330 watts MODULE LENGTH 66.85" MODULE WIDTH 39.53" MODULE THICKNESS 1.38" MODULE WEIGHT 41.20 lbs EXPANSION JOINTS Every 40' RAILS DIRECTION CROSS-SLOPE BUILDING HEIGHT 30.00 ft ROOF TYPE Other RAFTER SPACING 24.00" * TOTAL WEIGHT 457.32 lbs MID CLAMP Universal AF Clamp END CLAMP Universal AF Clamp * Calculated based on suggested quantity given on part list. 901 N Westwood Ave - 101111905-201773 06 03/29/23 Roof Area 1: Array 1 Landscape Modules - Rails Running Across Slope (for rails with attachments > 3) SOLARMOUNT LIGHT RAIL SPANS [IN] 1, 2E 2N, 2R, 3E 3R DESIGN SPAN (NON-EXPOSED)48 48 48 DESIGN SPAN (EXPOSED)48 48 48 Max Cantilever (Non-Exposed) 16 16 16 Max Cantilever (Exposed)16 16 16 Max Span (Non-Exposed)99 91 85 Max Span (Exposed)91 78 73 ZONES 1, 2E 2N, 2R, 3E 3R NO OF RAILS(EXPOSED)2 2 2 NO OF RAILS(NON-EXPOSED)2 2 2 DESIGN PRESSURES [PSF]1, 2E 2N, 2R, 3E 3R Up (Non-Exposed)-10.2 -16.1 -19.7 Up (Exposed)-16.1 -25.0 -30.4 Down (Non-Exposed)12.4 12.4 12.4 Down (Exposed)12.4 12.4 12.4 Downslope 2.1 2.1 2.1 Lateral 1.6 1.6 1.6 MAXIMUM POINT LOADS [LBS]1, 2E 2N, 2R, 3E 3R Up (Non-Exposed)-67.1 -106.2 -129.7 Up (Exposed)-106.2 -164.9 -200.2 Down (Non-Exposed)81.9 81.9 81.9 Down (Exposed)81.9 81.9 81.9 Downslope (Non-Exposed)13.5 13.5 13.5 Downslope (Exposed)13.5 13.5 13.5 Lateral (Non-Exposed)10.3 10.3 10.3 Lateral (Exposed)10.3 10.3 10.3 Tributary Area (Non-Exposed) [ft ] 6.6 6.6 6.6 Tributary Area (Exposed) [ft ] 6.6 6.6 6.6 ROOF PITCH:9° 2 2 901 N Westwood Ave - 101111905-201773 06 03/29/23 Landscape Modules - Rails Running Across Slope (for rails with attachments <= 3) SOLARMOUNT LIGHT RAIL SPANS [IN] 1, 2E 2N, 2R, 3E 3R DESIGN SPAN (NON-EXPOSED)48 48 48 DESIGN SPAN (EXPOSED)48 48 48 Max Cantilever (Non-Exposed) 16 16 16 Max Cantilever (Exposed)16 16 16 Max Span (Non-Exposed)99 91 85 Max Span (Exposed)91 78 73 ZONES 1, 2E 2N, 2R, 3E 3R NO OF RAILS(EXPOSED)2 2 2 NO OF RAILS(NON-EXPOSED)2 2 2 DESIGN PRESSURES [PSF]1, 2E 2N, 2R, 3E 3R Up (Non-Exposed)-10.2 -16.1 -19.7 Up (Exposed)-16.1 -25.0 -30.4 Down (Non-Exposed)12.4 12.4 12.4 Down (Exposed)12.4 12.4 12.4 Downslope 2.1 2.1 2.1 Lateral 1.6 1.6 1.6 MAXIMUM POINT LOADS [LBS]1, 2E 2N, 2R, 3E 3R Up (Non-Exposed)-67.1 -106.2 -129.7 Up (Exposed)-106.2 -164.9 -200.2 Down (Non-Exposed)81.9 81.9 81.9 Down (Exposed)81.9 81.9 81.9 Downslope (Non-Exposed)13.5 13.5 13.5 Downslope (Exposed)13.5 13.5 13.5 Lateral (Non-Exposed)10.3 10.3 10.3 Lateral (Exposed)10.3 10.3 10.3 Tributary Area (Non-Exposed) [ft ] 6.6 6.6 6.6 Tributary Area (Exposed) [ft ] 6.6 6.6 6.6 ROOF PITCH:9° 2 2 901 N Westwood Ave - 101111905-201773 06 03/29/23 Clamp Checks - Exposed zones ZONES 1, 2E 2N, 2R, 3E 3R CONNECTION-TYPE End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid Up Load N/A N/A N/A N/A N/A N/A N/A N/A N/A Check N/A N/A N/A N/A N/A N/A N/A N/A N/A Side Load N/A N/A N/A N/A N/A N/A N/A N/A N/A Check N/A N/A N/A N/A N/A N/A N/A N/A N/A Lateral Load N/A N/A N/A N/A N/A N/A N/A N/A N/A Check N/A N/A N/A N/A N/A N/A N/A N/A N/A Clamp Checks - Non-Exposed zones ZONES 1, 2E 2N, 2R, 3E 3R CONNECTION-TYPE End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid Up Load N/A 187 N/A N/A 296 N/A N/A 361 N/A Check N/A OK N/A N/A OK N/A N/A OK N/A Side Load N/A 38 N/A N/A 38 N/A N/A 38 N/A Check N/A OK N/A N/A OK N/A N/A OK N/A Lateral Load N/A 29 N/A N/A 29 N/A N/A 29 N/A Check N/A OK N/A N/A OK N/A N/A OK N/A N/A stands for not applicable 901 N Westwood Ave - 101111905-201773 06 03/29/23 Roof Area 1: Array 2 Portrait Modules - Rails Running Across Slope (for rails with attachments > 3) SOLARMOUNT LIGHT RAIL SPANS [IN] 1, 2E 2N, 2R, 3E 3R DESIGN SPAN (NON-EXPOSED)48 48 48 DESIGN SPAN (EXPOSED)48 48 48 Max Cantilever (Non-Exposed) 16 16 16 Max Cantilever (Exposed)16 16 16 Max Span (Non-Exposed)83 77 71 Max Span (Exposed)77 63 57 ZONES 1, 2E 2N, 2R, 3E 3R NO OF RAILS(EXPOSED)2 2 2 NO OF RAILS(NON-EXPOSED)2 2 2 DESIGN PRESSURES [PSF]1, 2E 2N, 2R, 3E 3R Up (Non-Exposed)-10.0 -15.4 -18.8 Up (Exposed)-15.8 -24.0 -29.1 Down (Non-Exposed)12.4 12.4 12.4 Down (Exposed)12.4 12.4 12.4 Downslope 2.1 2.1 2.1 Lateral 1.6 1.6 1.6 MAXIMUM POINT LOADS [LBS]1, 2E 2N, 2R, 3E 3R Up (Non-Exposed)-111.1 -171.7 -209.6 Up (Exposed)-176.1 -267.0 -323.8 Down (Non-Exposed)138.4 138.4 138.4 Down (Exposed)138.4 138.4 138.4 Downslope (Non-Exposed)22.9 22.9 22.9 Downslope (Exposed)22.9 22.9 22.9 Lateral (Non-Exposed)17.4 17.4 17.4 Lateral (Exposed)17.4 17.4 17.4 Tributary Area (Non-Exposed) [ft ] 11.1 11.1 11.1 Tributary Area (Exposed) [ft ] 11.1 11.1 11.1 ROOF PITCH:9° 2 2 901 N Westwood Ave - 101111905-201773 06 03/29/23 Portrait Modules - Rails Running Across Slope (for rails with attachments <= 3) SOLARMOUNT LIGHT RAIL SPANS [IN] 1, 2E 2N, 2R, 3E 3R DESIGN SPAN (NON-EXPOSED)48 48 48 DESIGN SPAN (EXPOSED)48 48 48 Max Cantilever (Non-Exposed) 16 16 16 Max Cantilever (Exposed)16 16 16 Max Span (Non-Exposed)83 77 71 Max Span (Exposed)77 63 57 ZONES 1, 2E 2N, 2R, 3E 3R NO OF RAILS(EXPOSED)2 2 2 NO OF RAILS(NON-EXPOSED)2 2 2 DESIGN PRESSURES [PSF]1, 2E 2N, 2R, 3E 3R Up (Non-Exposed)-10.0 -15.4 -18.8 Up (Exposed)-15.8 -24.0 -29.1 Down (Non-Exposed)12.4 12.4 12.4 Down (Exposed)12.4 12.4 12.4 Downslope 2.1 2.1 2.1 Lateral 1.6 1.6 1.6 MAXIMUM POINT LOADS [LBS]1, 2E 2N, 2R, 3E 3R Up (Non-Exposed)-111.1 -171.7 -209.6 Up (Exposed)-176.1 -267.0 -323.8 Down (Non-Exposed)138.4 138.4 138.4 Down (Exposed)138.4 138.4 138.4 Downslope (Non-Exposed)22.9 22.9 22.9 Downslope (Exposed)22.9 22.9 22.9 Lateral (Non-Exposed)17.4 17.4 17.4 Lateral (Exposed)17.4 17.4 17.4 Tributary Area (Non-Exposed) [ft ] 11.1 11.1 11.1 Tributary Area (Exposed) [ft ] 11.1 11.1 11.1 ROOF PITCH:9° 2 2 901 N Westwood Ave - 101111905-201773 06 03/29/23 Clamp Checks - Exposed zones ZONES 1, 2E 2N, 2R, 3E 3R CONNECTION-TYPE End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid Up Load N/A N/A N/A N/A N/A N/A N/A N/A N/A Check N/A N/A N/A N/A N/A N/A N/A N/A N/A Side Load N/A N/A N/A N/A N/A N/A N/A N/A N/A Check N/A N/A N/A N/A N/A N/A N/A N/A N/A Lateral Load N/A N/A N/A N/A N/A N/A N/A N/A N/A Check N/A N/A N/A N/A N/A N/A N/A N/A N/A Clamp Checks - Non-Exposed zones ZONES 1, 2E 2N, 2R, 3E 3R CONNECTION-TYPE End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid End-End End-Mid Mid-Mid Up Load N/A N/A N/A 296 N/A N/A N/A N/A N/A Check N/A N/A N/A OK N/A N/A N/A N/A N/A Side Load N/A N/A N/A 38 N/A N/A N/A N/A N/A Check N/A N/A N/A OK N/A N/A N/A N/A N/A Lateral Load N/A N/A N/A 29 N/A N/A N/A N/A N/A Check N/A N/A N/A OK N/A N/A N/A N/A N/A N/A stands for not applicable 901 N Westwood Ave - 101111905-201773 06 03/29/23 SOLARMOUNT Flush Product Assumptions Limitations of Responsibility: It is the user’s responsibility to ensure that inputs are correct for your specific project. Unirac is not the solar, electrical, or building engineer of record and is not responsible for the solar, electrical, or building design for this project. Allowable spans and resulting point loads are subject to the following conditions: 1. Building Height ≤ 60 ft unless otherwise specified. 2. Roof Slope ≥ 1.2° 3. Maximum rail cantilever ≤ 1/3 of selected span. 4. Occupancy/Risk Category = II unless otherwise specifi ed. 5. ASCE 7-05: Basic Wind Speed: 85-170 mph (IBC 2006/ASCE 7-05). Wind Exposure: B, C or D. 6. ASCE 7-10: Basic Wind Speed: 95-190 mph (IBC 2012/ASCE 7-10). Wind Exposure: B, C or D. 7. ASCE 7-16: Basic Wind Speed: 85-190 mph (IBC 2018/ASCE 7-16). Wind Exposure: B, C or D. 8. Ground Snow Load: 0-100 psf. (Reduction can be input if this is acceptable with your local building authority). Results are based on uniform snow loading and do not consider unbalanced, drifting, and sliding conditions. 9. Dead Load ≤ 5 psf (includes PV Modules and Racking). 10. Maximum PV Module Length: 85 in. 11. Seismic: Installations must be in seismic site class A, B, C, or D as defined in IBC 2006/ASCE 7-05. 12. Intermediary Span Distances: Roof attachment point loads be reduced linearly if the installed distance between the attachments is less than the selected span. For example, if the spacing is half the amount shown in the results, then the point loads may also be reduced by half. 13. Spans greater than 96 in.: While our products are valid for greater spans in many instances, we do not recommend this mounting configuration. Typical residential roofs are not designed for the larger point loads that might result from such excessive spans and we recommend final design by a licensed professional engineer of responsible charge. Pitched Roof Solutions (Flush Mounted Solutions): Modules are parallel to the roof surface and within 10 in. of it. Allowable roof pitch: 1.2°-45°. (SM is not fire tested for sloped of < 2:12, please check with your AHJ if this is acceptable.) Building has a monoslope roof with a slope ≤ 3°, a gable roof ≤ 45°, or a hip roof ≤ 27°. 901 N Westwood Ave - 101111905-201773 06 03/29/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 901 NORTH WESTWOOD AVE SANTA ANA, CA 92703 Empower Solar Inc. 1057693 Genevieve Silva 9519909049 6/15/22 socalpermits@mpwrsolar.com 901 N Westwood Ave - 101111905-201773 06 03/29/23 1300 E. Shaw Ave, #173 Fresno, CA 93710 Empower Solar Inc 800-306-6953 CSLB: 1057693 Customer Acknowledgement I, ________________________________, have agreed to have solar installed by Empower Solar Inc. (CLSB# 1057693) I authorize them to submit and receive permit for my solar install on my behalf. I hereby revoke any other solar permits for the address listed below. Address: _____________________________________________________________ Phone #: _____________________________________________________________ Email Address: ________________________________________________________ Customer Installer Name: ___________________ Name: _____________________ Signature: ________________ Signature: __________________ Date: ____________________ Date: ______________________ 901 North Westwood Avenue Santa Ana, California - 92703 (657) 720-8175 ernigarcia05051973@icloud.com GUMERSINDO GUERRERO GARCIA Empower Solar Inc - Genevieve Silva (applicant) 6/22/2022 Tracking Numbers: 101109893 / 20175779 Gumersindo Guerrero Garcia Gumersindo Guerrero (Aug 2, 2022 09:35 PDT) 08/02/22 901 N Westwood Ave - 101111905-201773 06 03/29/23 GGgarciaAuthLetter (1) (2) Final Audit Report 2022-08-02 Created:2022-08-02 By:Empower Solar (mandy@mpwrsolar.com) Status:Signed Transaction ID: CBJCHBCAABAAlOR95jSvGLtH1WDL_0fidxmz36VAdWIp "GGgarciaAuthLetter (1) (2)" History Document created by Empower Solar (mandy@mpwrsolar.com) 2022-08-02 - 4:00:36 PM GMT- IP address: 108.64.108.13 Document emailed to Gumersindo Guerrero (ernigarcia05051973@icloud.com) for signature 2022-08-02 - 4:05:12 PM GMT Email viewed by Gumersindo Guerrero (ernigarcia05051973@icloud.com) 2022-08-02 - 4:31:13 PM GMT- IP address: 104.28.85.126 Document e-signed by Gumersindo Guerrero (ernigarcia05051973@icloud.com) Signature Date: 2022-08-02 - 4:35:18 PM GMT - Time Source: server- IP address: 172.58.23.243 Agreement completed. 2022-08-02 - 4:35:18 PM GMT 901 N Westwood Ave - 101111905-201773 06 03/29/23 901 N Westwood Ave - 101111905-201773 06 03/29/23 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-9 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-10 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-11 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-12 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-13 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-14 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-15 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-16 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-17 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-18 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-19 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 REV SHEET NAME SHEET NUMBER DATE DESCRIPTION VERSION PV-20 PROJECT NAME UR06/03/2022 INITIAL RELEASE GU M E R S I N D O G U E R R E R O G A R C I A 90 1 N O R T H W E S T W O O D A V E , SA N T A A N A , C A 9 2 7 0 3 U S A AP N # 4 0 5 2 3 1 2 2 UT I L I T Y : S C E AH J : C I T Y O F S A N T A A N A SHEET SIZE ANSI B 11" X 17" EMPOWER ELECTRIC SOLAR 1300 E SHAW AVE, 173 FRESNO, CA 93710 TEL: (559) 360-9292 CSLB: 1057693 Email: permits@mpwrsolar.com SPEC SHEETS 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : UNIRAC 1411 Broadway Blvd, NE Albuquerque, NM 87102 RE: Solar Array Installation at 901 North Westwood Ave, Santa Ana, CA, 92703, USA To Whom it May Concern, CODE REFERENCES: BUILDING CODE: 2019 CALIFORNIA BUILDING CODE 2018 INTERNATIONAL BUILDING CODE ASCE 7-16 SCOPE OF WORK: DESIGN PARAMETERS RISK CATEGORY : DESIGN WIND SPEED :mph WIND EXPOSURE : GROUND SNOW LOAD :psf SEISMIC DESIGN CATEGORY : EXISTING ROOF STRUCTURE ROOF : 2x4 Rafters @ 24" O.C. ROOF MATERIAL : Rolled Comp CONNECTION TO ROOF STRUCTURE MOUNTING CONNECTION : Gumersindo Guerrero Garcia PE 07-02-2023 Roof structural framing plan has been reviewed for additional loading due to installation of the roof mounted solar PV addition. The structural review that follows, including plans and calculations, only apply to the section of the roof that is directly supporting the solar PV system and its supporting elements. Tuesday, February 7, 2023 Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof per layout plan. (2) #12 WOOD SCREW w/ MIN. 2.5" EMBEDMENT INTO (E) 2x FRAMING MEMBER @ MAX. 48" O.C. ALONG RAILS (2) RAILS PER ROW OF PANELS, EVENLY SPACED. PANEL LENGTH PERPENDICULAR TO RAIL NOT TO EXCEED 67.79" II 95 B 0 *null 901 N Westwood Ave - 101111905-201773 06 03/29/23 OBSERVED CONDITIONS: CONCLUSIONS: LIMITATIONS: Praneet R Erusu, P.E. Principal Engineer Erusu Consultants US Inc. The observed roof framing is described below. If field conditions differ, the contractor shall notify the engineer prior to starting construction. The roof framing is supported by 2x4 Rafters @ 24" O.C are spanning between load bearing walls. The maximum allowed clear span of rafter is 9.5ft, to be verified in field by the contractor. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array, other live loads will not be present or will be greatly reduced (2019 CBC, Section 1607.13.5). The gravity loads and the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2019 CEBC are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Regarding seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 6.5%. Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2019 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered. Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Existing Roof and structural members are assumed to be in good and serviceable condition. The contractor must notify Erusu Consultants US Inc. should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. The use of solar panel support span tables provided by others are allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. The design of the solar panel racking (mounts, rails, etc.) and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Erusu Consultants US Inc. assumes no responsibility for improper installation of the solar array. 07 Feb 2023 EXP : 30 Sep 2023 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : Address : Site Plan: Gumersindo Guerrero Garcia PE 07-02-2023 901 North Westwood Ave, Santa Ana, CA, 92703, USA 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : Roof Dead Load Roof Slope =: Angle = Roof Live Load Roof Live Load = psf (Refer ASCE 7-16, Table 4.3-1) Roof Live Load with PV Array = psf 2019 CBC, Section 1607.13.5 (Ceiling load and MEP is assumed to be not supported by rafter) 3.01 1/2" Gypsum Ceiling Gumersindo Guerrero Garcia PE 07-02-2023 DL = Increase due to Roof Slope Plan Projected Material Weight (psf) 4.01 1.10 3.01 0.50Insulation0.5 1.00 2.21 1.50 12.34 1/2" Plywood 1.1 1.00 Framing 3 1.00 Rolled Comp 4 1.00 1 12 5 Material Material Weight (psf) PV Array 3 1.00 2.2 1.00 MEP & Misc.1.5 20 0 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : Gumersindo Guerrero Garcia PE 07-02-2023 Summary of Gravity Loads Dead Load, D =psf Roof Live Load, Lr =psf Gravity Load Comparison (D + Lr)/Cd =psf (Cd = 0.9 for D, 1.15 for S, 1.25 for Lr) Max Loading =psf Proposed to Current Loading Ratio = Existing With PV Array 12.34 15.35 29.71 17.05 20.00 0.00 Existing With PV Array O.K. Gravity Loading with PV Array is not stressing the current framing system by more that 5% of the original configuration. Per Section 503.3 of 2019 California Existing Building Code the structure is allowed to remain unaltered for gravity loading 29.71 17.05 57% < 105% 901 N Westwood Ave - 101111905-201773 06 03/29/23 Wood Beam LIC# : KW-06014559, Build:20.22.12.28 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2022 DESCRIPTION: 2x4 Rafters @ 24" o.c. (Wind Condition_Downward) (Strength Check) Project File: 2x4 Joist @ 24 O.C..ec6 Project Title: Engineer: Project ID: Printed: 7 FEB 2023, 5:17PM Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination : ASCE 7-16 . Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.00810, Lr = 0.020, W = 0.0160 ksf, Tributary Width = 2.0 ft, (Existing Roof load) Load for Span Number 2 Uniform Load : D = 0.00810 ksf, Tributary Width = 2.0 ft, (Existing Roof Dead load) Point Load : D = 0.0340, W = 0.1810 k @ 5.60 ft, (Solar panel load) Point Load : D = 0.0340, W = 0.1810 k @ 9.250 ft, (Solar panel load) Uniform Load : Lr = 0.020, W = 0.0160 ksf, Extent = 0.0 -->> 4.60 ft, Tributary Width = 2.0 ft, (Existing Roof live & wind load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.950: 1 Load Combination +D+0.750Lr+0.750L+0.450W+H Span # where maximum occurs Span # 2 Location of maximum on span 5.573 ft 65.19 psi= = 2,484.00 psi 2x4 Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr+H = = = 225.00 psi== Section used for this span 2x4 Maximum Shear Stress Ratio 0.290 : 1 2.000 ft= = 2,360.49 psi Maximum Deflection 86 >=86 103 Ratio =72 >=71 Max Downward Transient Deflection 0.934 in 122 Ratio =>=86 Max Upward Transient Deflection -0.557 in Ratio = Max Downward Total Deflection 1.098 in Ratio =>=71 Max Upward Total Deflection -0.656 in fb: Actual F'b fv: Actual F'v Span: 2 : W Only Span: 1 : W Only Span: 2 : +D+0.750Lr+0.750L+0.450W+H Span: 1 : +D+0.750Lr+0.750L+0.450W+H .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C i CLx CCCM C F r t Shear ValuesMax Stress Ratios M CD V fb M fv F'b V F'v Segment Length Cfu +D+H 0.0 0.00 0.00.0 1.00 Length = 2.0 ft 1 0.091 0.160 0.90 1.500 1.15 1.00 1.00 0.03 127.0 1,397.3 0.09 162.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.692 0.160 0.90 1.500 1.15 1.00 1.00 0.25 966.5 1,397.3 0.09 162.01.00 26.0 1.00 1.00 +D+L+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.082 0.144 1.00 1.500 1.15 1.00 1.00 0.03 127.0 1,552.5 0.09 180.01.00 26.0 1.00 901 N Westwood Ave - 101111905-201773 06 03/29/23 Wood Beam LIC# : KW-06014559, Build:20.22.12.28 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2022 DESCRIPTION: 2x4 Rafters @ 24" o.c. (Wind Condition_Downward) (Strength Check) Project File: 2x4 Joist @ 24 O.C..ec6 Project Title: Engineer: Project ID: Printed: 7 FEB 2023, 5:17PM Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCM C F r t Shear ValuesMax Stress Ratios M CD V fb M fv F'b V F'vSegment Length Cfu 1.00 Length = 9.50 ft 2 0.623 0.144 1.00 1.500 1.15 1.00 1.00 0.25 966.5 1,552.5 0.09 180.01.00 26.0 1.00 1.00 +D+Lr+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.227 0.290 1.25 1.500 1.15 1.00 1.00 0.11 440.4 1,940.6 0.23 225.01.00 65.2 1.00 1.00 Length = 9.50 ft 2 0.835 0.290 1.25 1.500 1.15 1.00 1.00 0.41 1,619.5 1,940.6 0.23 225.01.00 65.2 1.00 1.00 +D+S+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.071 0.125 1.15 1.500 1.15 1.00 1.00 0.03 127.0 1,785.4 0.09 207.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.541 0.125 1.15 1.500 1.15 1.00 1.00 0.25 966.5 1,785.4 0.09 207.01.00 26.0 1.00 1.00 +D+0.750Lr+0.750L+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.187 0.246 1.25 1.500 1.15 1.00 1.00 0.09 362.1 1,940.6 0.19 225.01.00 55.4 1.00 1.00 Length = 9.50 ft 2 0.742 0.246 1.25 1.500 1.15 1.00 1.00 0.37 1,439.6 1,940.6 0.19 225.01.00 55.4 1.00 1.00 +D+0.750L+0.750S+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.071 0.125 1.15 1.500 1.15 1.00 1.00 0.03 127.0 1,785.4 0.09 207.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.541 0.125 1.15 1.500 1.15 1.00 1.00 0.25 966.5 1,785.4 0.09 207.01.00 26.0 1.00 1.00 +D+0.60W+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.112 0.203 1.60 1.500 1.15 1.00 1.00 0.07 277.4 2,484.0 0.20 288.01.00 58.4 1.00 1.00 Length = 9.50 ft 2 0.914 0.203 1.60 1.500 1.15 1.00 1.00 0.58 2,269.2 2,484.0 0.20 288.01.00 58.4 1.00 1.00 +D+0.750Lr+0.750L+0.450W+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.191 0.277 1.60 1.500 1.15 1.00 1.00 0.12 474.9 2,484.0 0.28 288.01.00 79.7 1.00 1.00 Length = 9.50 ft 2 0.950 0.277 1.60 1.500 1.15 1.00 1.00 0.60 2,360.5 2,484.0 0.28 288.01.00 79.7 1.00 1.00 +D+0.750L+0.750S+0.450W+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.097 0.175 1.60 1.500 1.15 1.00 1.00 0.06 239.8 2,484.0 0.18 288.01.00 50.3 1.00 1.00 Length = 9.50 ft 2 0.782 0.175 1.60 1.500 1.15 1.00 1.00 0.50 1,943.5 2,484.0 0.18 288.01.00 50.3 1.00 1.00 +0.60D+0.60W+0.60H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.091 0.167 1.60 1.500 1.15 1.00 1.00 0.06 226.6 2,484.0 0.17 288.01.00 48.0 1.00 1.00 Length = 9.50 ft 2 0.758 0.167 1.60 1.500 1.15 1.00 1.00 0.48 1,882.6 2,484.0 0.17 288.01.00 48.0 1.00 1.00 +D+0.70E+0.60H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.051 0.090 1.60 1.500 1.15 1.00 1.00 0.03 127.0 2,484.0 0.09 288.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.389 0.090 1.60 1.500 1.15 1.00 1.00 0.25 966.5 2,484.0 0.09 288.01.00 26.0 1.00 1.00 +D+0.750L+0.750S+0.5250E+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.051 0.090 1.60 1.500 1.15 1.00 1.00 0.03 127.0 2,484.0 0.09 288.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.389 0.090 1.60 1.500 1.15 1.00 1.00 0.25 966.5 2,484.0 0.09 288.01.00 26.0 1.00 1.00 +0.60D+0.70E+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.031 0.054 1.60 1.500 1.15 1.00 1.00 0.02 76.2 2,484.0 0.05 288.01.00 15.6 1.00 1.00 Length = 9.50 ft 2 0.233 0.054 1.60 1.500 1.15 1.00 1.00 0.15 579.9 2,484.0 0.05 288.01.00 15.6 1.00 . Location in SpanLoad CombinationMax. "-" Defl Location in Span Load Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.750Lr+0.750L+0.450W+H 1 0.0000 0.000 -0.6558 0.000 +D+0.750Lr+0.750L+0.450W+H 2 1.0977 4.830 0.0000 0.000 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.416 0.314 Max Upward from Load Combinations 0.416 0.314 Max Upward from Load Cases 0.261 0.312 +D+H 0.128 0.127 +D+L+H 0.128 0.127 +D+Lr+H 0.355 0.163 +D+S+H 0.128 0.127 +D+0.750Lr+0.750L+H 0.299 0.154 +D+0.750L+0.750S+H 0.128 0.127 901 N Westwood Ave - 101111905-201773 06 03/29/23 Wood Beam LIC# : KW-06014559, Build:20.22.12.28 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2022 DESCRIPTION: 2x4 Rafters @ 24" o.c. (Wind Condition_Downward) (Strength Check) Project File: 2x4 Joist @ 24 O.C..ec6 Project Title: Engineer: Project ID: Printed: 7 FEB 2023, 5:17PM Project Descr: Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +D+0.60W+H 0.284 0.314 +D+0.750Lr+0.750L+0.450W+H 0.416 0.294 +D+0.750L+0.750S+0.450W+H 0.245 0.267 +0.60D+0.60W+0.60H 0.233 0.263 +D+0.70E+0.60H 0.128 0.127 +D+0.750L+0.750S+0.5250E+H 0.128 0.127 +0.60D+0.70E+H 0.077 0.076 D Only 0.128 0.127 Lr Only 0.228 0.036 W Only 0.261 0.312 H Only 901 N Westwood Ave - 101111905-201773 06 03/29/23 Wood Beam LIC# : KW-06014559, Build:20.22.12.28 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2022 DESCRIPTION: 2x4 Rafters @ 24" o.c. (Wind Condition_Uplift) (Strength Check) Project File: 2x4 Joist @ 24 O.C..ec6 Project Title: Engineer: Project ID: Printed: 7 FEB 2023, 5:17PM Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2018, CBC 2019, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing : Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination : ASCE 7-16 . Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.00810, Lr = 0.020, W = -0.030 ksf, Tributary Width = 2.0 ft, (Existing Roof load) Load for Span Number 2 Uniform Load : D = 0.00810 ksf, Tributary Width = 2.0 ft, (Existing Roof Dead load) Point Load : D = 0.0340, W = -0.3370 k @ 5.60 ft, (Solar panel load) Point Load : D = 0.0340, W = -0.3370 k @ 9.250 ft, (Solar panel load) Uniform Load : Lr = 0.020, W = -0.030 ksf, Extent = 0.0 -->> 4.60 ft, Tributary Width = 2.0 ft, (Existing Roof live & wind load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.835: 1 Load Combination +D+Lr+H Span # where maximum occurs Span # 2 Location of maximum on span 4.299 ft 65.19 psi= = 1,940.63 psi 2x4 Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr+H = = = 225.00 psi== Section used for this span 2x4 Maximum Shear Stress Ratio 0.290 : 1 2.000 ft= = 1,619.47 psi Maximum Deflection 65 >=46 102 Ratio =104 >=101 Max Downward Transient Deflection 1.039 in 46 Ratio =>=46 Max Upward Transient Deflection -1.742 in Ratio = Max Downward Total Deflection 0.467 in Ratio =>=101 Max Upward Total Deflection -0.453 in fb: Actual F'b fv: Actual F'v Span: 2 : Lr Only Span: 2 : W Only Span: 2 : +D+Lr+H Span: 2 : +0.60D+0.60W+0.60H .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C i CLx CCCM C F r t Shear ValuesMax Stress Ratios M CD V fb M fv F'b V F'v Segment Length Cfu +D+H 0.0 0.00 0.00.0 1.00 Length = 2.0 ft 1 0.091 0.160 0.90 1.500 1.15 1.00 1.00 0.03 127.0 1,397.3 0.09 162.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.692 0.160 0.90 1.500 1.15 1.00 1.00 0.25 966.5 1,397.3 0.09 162.01.00 26.0 1.00 1.00 +D+L+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.082 0.144 1.00 1.500 1.15 1.00 1.00 0.03 127.0 1,552.5 0.09 180.01.00 26.0 1.00 901 N Westwood Ave - 101111905-201773 06 03/29/23 Wood Beam LIC# : KW-06014559, Build:20.22.12.28 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2022 DESCRIPTION: 2x4 Rafters @ 24" o.c. (Wind Condition_Uplift) (Strength Check) Project File: 2x4 Joist @ 24 O.C..ec6 Project Title: Engineer: Project ID: Printed: 7 FEB 2023, 5:17PM Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCM C F r t Shear ValuesMax Stress Ratios M CD V fb M fv F'b V F'vSegment Length Cfu 1.00 Length = 9.50 ft 2 0.623 0.144 1.00 1.500 1.15 1.00 1.00 0.25 966.5 1,552.5 0.09 180.01.00 26.0 1.00 1.00 +D+Lr+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.227 0.290 1.25 1.500 1.15 1.00 1.00 0.11 440.4 1,940.6 0.23 225.01.00 65.2 1.00 1.00 Length = 9.50 ft 2 0.835 0.290 1.25 1.500 1.15 1.00 1.00 0.41 1,619.5 1,940.6 0.23 225.01.00 65.2 1.00 1.00 +D+S+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.071 0.125 1.15 1.500 1.15 1.00 1.00 0.03 127.0 1,785.4 0.09 207.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.541 0.125 1.15 1.500 1.15 1.00 1.00 0.25 966.5 1,785.4 0.09 207.01.00 26.0 1.00 1.00 +D+0.750Lr+0.750L+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.187 0.246 1.25 1.500 1.15 1.00 1.00 0.09 362.1 1,940.6 0.19 225.01.00 55.4 1.00 1.00 Length = 9.50 ft 2 0.742 0.246 1.25 1.500 1.15 1.00 1.00 0.37 1,439.6 1,940.6 0.19 225.01.00 55.4 1.00 1.00 +D+0.750L+0.750S+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.071 0.125 1.15 1.500 1.15 1.00 1.00 0.03 127.0 1,785.4 0.09 207.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.541 0.125 1.15 1.500 1.15 1.00 1.00 0.25 966.5 1,785.4 0.09 207.01.00 26.0 1.00 1.00 +D+0.60W+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.062 0.120 1.60 1.500 1.15 1.00 1.00 0.04 155.2 2,484.0 0.12 288.01.00 34.6 1.00 1.00 Length = 9.50 ft 2 0.589 0.120 1.60 1.500 1.15 1.00 1.00 0.37 1,462.6 2,484.0 0.12 288.01.00 34.6 1.00 1.00 +D+0.750Lr+0.750L+0.450W+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.061 0.035 1.60 1.500 1.15 1.00 1.00 0.04 150.5 2,484.0 0.03 288.01.00 10.0 1.00 1.00 Length = 9.50 ft 2 0.177 0.064 1.60 1.500 1.15 1.00 1.00 0.11 439.9 2,484.0 0.06 288.01.00 18.3 1.00 1.00 +D+0.750L+0.750S+0.450W+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.034 0.067 1.60 1.500 1.15 1.00 1.00 0.02 84.6 2,484.0 0.07 288.01.00 19.4 1.00 1.00 Length = 9.50 ft 2 0.344 0.079 1.60 1.500 1.15 1.00 1.00 0.22 855.3 2,484.0 0.08 288.01.00 22.8 1.00 1.00 +0.60D+0.60W+0.60H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.083 0.156 1.60 1.500 1.15 1.00 1.00 0.05 205.9 2,484.0 0.16 288.01.00 44.9 1.00 1.00 Length = 9.50 ft 2 0.744 0.156 1.60 1.500 1.15 1.00 1.00 0.47 1,849.2 2,484.0 0.16 288.01.00 44.9 1.00 1.00 +D+0.70E+0.60H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.051 0.090 1.60 1.500 1.15 1.00 1.00 0.03 127.0 2,484.0 0.09 288.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.389 0.090 1.60 1.500 1.15 1.00 1.00 0.25 966.5 2,484.0 0.09 288.01.00 26.0 1.00 1.00 +D+0.750L+0.750S+0.5250E+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.051 0.090 1.60 1.500 1.15 1.00 1.00 0.03 127.0 2,484.0 0.09 288.01.00 26.0 1.00 1.00 Length = 9.50 ft 2 0.389 0.090 1.60 1.500 1.15 1.00 1.00 0.25 966.5 2,484.0 0.09 288.01.00 26.0 1.00 1.00 +0.60D+0.70E+H 1.500 1.15 1.00 1.00 0.0 0.00 0.01.00 0.0 1.00 1.00 Length = 2.0 ft 1 0.031 0.054 1.60 1.500 1.15 1.00 1.00 0.02 76.2 2,484.0 0.05 288.01.00 15.6 1.00 1.00 Length = 9.50 ft 2 0.233 0.054 1.60 1.500 1.15 1.00 1.00 0.15 579.9 2,484.0 0.05 288.01.00 15.6 1.00 . Location in SpanLoad CombinationMax. "-" Defl Location in Span Load Combination Span Max. "+" Defl Overall Maximum Deflections W Only 1 1.0391 0.000 0.0000 0.000 W Only20.0000 0.000 -1.7420 4.883 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.355 0.163 Max Upward from Load Combinations 0.355 0.163 Max Upward from Load Cases 0.228 0.127 Max Downward from all Load Conditio -0.489 -0.581 Max Downward from Load Combinations -0.217 -0.273 Max Downward from Load Cases (Resis -0.489 -0.581 +D+H 0.128 0.127 +D+L+H 0.128 0.127 +D+Lr+H 0.355 0.163 901 N Westwood Ave - 101111905-201773 06 03/29/23 Wood Beam LIC# : KW-06014559, Build:20.22.12.28 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2022 DESCRIPTION: 2x4 Rafters @ 24" o.c. (Wind Condition_Uplift) (Strength Check) Project File: 2x4 Joist @ 24 O.C..ec6 Project Title: Engineer: Project ID: Printed: 7 FEB 2023, 5:17PM Project Descr: Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +D+S+H 0.128 0.127 +D+0.750Lr+0.750L+H 0.299 0.154 +D+0.750L+0.750S+H 0.128 0.127 +D+0.60W+H -0.166 -0.222 +D+0.750Lr+0.750L+0.450W+H 0.078 -0.108 +D+0.750L+0.750S+0.450W+H -0.092 -0.135 +0.60D+0.60W+0.60H -0.217 -0.273 +D+0.70E+0.60H 0.128 0.127 +D+0.750L+0.750S+0.5250E+H 0.128 0.127 +0.60D+0.70E+H 0.077 0.076 D Only 0.128 0.127 Lr Only 0.228 0.036 W Only -0.489 -0.581 H Only 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : Wind Load Calculation Wind Loads - ASCE 7-16 Chapter 26 & 29 Width of the Building, B = ft (Approximate) V = mph Exposure = Average height of building, z = ft - avg (Approximate) ft (Refer ASCE 7-16, Table 26.10-1) α = Zg = ft (Refer ASCE 7-16, Table 26.11-1) Kh & Kz = 2.01(z/Zg)^(2/α) = Kzt =(Refer ASCE 7-16, Equation 26.8-1) Kd =(Refer ASCE 7-16, Table 26.6.1) Ke =(Refer ASCE 7-16, Table 26.9-1) qh ='.00256 KzKztKdKeV² =psf (Refer ASCE 7-16, Section 26.10-1) Building Classification = Solar Panel Components and Cladding p C&C = qh(GCp)(ϒe)(ϒa) ASCE 7-16 Chapter 29.4.4 Module Length = in Module Width = in Area of Module = ft2 Roof Pitch =: Slope = degrees Gable Roof = ϒe= ϒa=(Refer ASCE 7-16, Figure 29.4-8) Gumersindo Guerrero Garcia PE 07-02-2023 1200 zmin = 30 7 1 49.1 1 0.85 11.29 1.0 44.64 95 B 15 0.57 Enclosed 0.8 21.0 67.79 θ ≤ 7° 1.5 12 5 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : Gumersindo Guerrero Garcia PE 07-02-2023 Zone 1 Uplift External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf Zone 2 Uplift External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf All Zone Downward External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf Maximum Uplift Wind Pressure, p = psf Minimum Downward Wind Pressure ,p = psf Wood Screw Connection Check (ASD) Tributary Width = in (Max Spacing of fasteners along Rails) Tributary Length = in (Half Panel Length) Tributary Area = ft2 Wood Screw Number = Cd =(Refer NDS Table 2.3.2) Embedment = in Grade of Wood = #2 ( or better) G = Capacity = lb/in (Refer NDS Table 12.2B) Number of Screws in Tension = Prying Coefficient = Capacity of Fasteners = lb Demand -2.2 (Measured from top of the framing member to tapered tip of wood screw, embedment in sheathing and tapered tip of screw is not included ) DF -29.80 -1.6 -21.67 -29.80 16.0 33.895 11.3 #12 1.6 2.5 48 0.3 4.1 Uplift (lb) Zone 0.5 154 2 1.4 880 Zone 1 Zone 2 0.23 Pressure ASD (0.6W)(psf) -13.0 -17.9 11.3 202.0 880 DCR 11.3 146.9 880 0.17 Capacity (lb)Tributary Area (ft2) 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : Seismic Ground Motion Values Gumersindo Guerrero Garcia PE 07-02-2023 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : Seismic Design Force Seismic Loads - ASCE 7-16 Chapter 13 Seismic Force Component Amplification Factor, ap= (Refer ASCE 7-16, Table 13.6 -1) Overstrength Factor, Ωo =(Refer ASCE 7-16, Table 13.6 -1) Component Importance Factor, Ip= SDS = Average roof height of structure,h = ft z/h = z/h should not exceed 1 Frame Weight Wp = psf Seismic Design Force on Solar framing structure Max Fp =1.6 x SDS x Ip X Wp = psf Min Fp =0.3 x SDS x Ip X Wp = psf Seismic Design Load Fp = psf Vertical Seismic Design Load Fp = psf Seismic Coefficients for Mechanical and Electrical components = Component Response Modification Factor, Rp= 1.50 Gumersindo Guerrero Garcia PE 07-02-2023 12 Other mechanical or electrical components. (Refer ASCE 7-16, Table 13.6 -1) Height in structure at point of attachment, z = 15 ft 1.00 1.50 1.04 1.00 F P = ((0.4 x ap x SDS x Wp)/ (Rp / Ip)) x ((1+2(z/h)) =2.51 psf 15 1 2.51 5.02 0.94 3.01 0.63 901 N Westwood Ave - 101111905-201773 06 03/29/23 Project : Project Number: By : Date : Gumersindo Guerrero Garcia PE 07-02-2023 Check for Increase in overall seismic loads Array Area = ft2 Number of Arrays = Total Array Area = ft2 Array Load = psf Number of Existing Arrays = Existing Area = ft2 Total Array Wt. = lb Total Roof Area = ft2 DL of Roof = psf Total Wt. of Roof = lb Increase in Seismic Wt. = < 10% Conservatively the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less than 10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2019 CEBC. 21.0 9 189.13 2211.7 3.00 1766.2 22 399.60 12.34 27287 6.5% 901 N Westwood Ave - 101111905-201773 06 03/29/23