Loading...
HomeMy WebLinkAbout1402 E 18th St - PlanBE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 OWNER Martin Angel PHONE: 1714-585-0226 EMAIL: martin.angel@ocpw.ocgov.com CONTRACTOR: BETTER EARTH ELECTRIC INC. PHONE: (888)373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: Santa Ana (CA) UTILITY: Southern California Edison DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH ROOF SURFACE: 2696 SQ.FT. PV SQ FOOTAGE: 320.13 SQ.FT. PV COVERAGE: 11.3 % WEIGHT OF EQUIPMENT: 715.35 NO. OF STORIES: FIRE SPRINKLERS: NO LOT INFORMATION APN: 39622131 LOT AREA: 7482 LIVING AREA: 1964 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 9/27/2022 9/27/2022 DATE: TIME: 01:40 pm 01:40 pm PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. PROPERTY INFORMATION Martin Angel 1402 E 18th St, Santa Ana, CA 92705 APN: 39622131 N SYSTEM SIZE: 5925 DC N SYSTEM SIZE: 5000 AC N CEC POWER OUTPUT: 5535 CEC MODULE INFORMATION MODULE QTY: 15 MODULE MFG: Canadian MODULE TYPE: Canadian CS3N-395 INVERTER INFORMATION INVERTER QTY:1 INVERTER MFG:SOLAREDGE INVERTER TYPE:5000H-US Non-RGM POWER OPTIMIZER INFORMATION OPTIMIZER QTY: 15 OPTIMIZER MFG: SOLAREDGE OPTIMIZER TYPE: S440 PROJECT DETAILS COVER SHEET P1 TABLE OF CONTENTS PAGE NUMBER: PAGE TITLE: P1 COVER SHEET P2 SITE PLAN P3 ROOF PLAN P4 RACKING & FRAMING P5 LINE DIAGRAM & DESIGN TABLES P6 PLACARDS & PLACARD MAP P7 OPTIMIZER MAP P8 JOB HAZARD ANALYSIS P9 ELEC. LOAD CALCS SS00 SPECIFICATION PAGES RAILING INFORMATION RAILING MFG:UNIRAC RAILING TYPE:Unirac SM Light MOUNTING INFORMATION MOUNT FLASHING QTY:30 MOUNT FLASHING MFG:UNIRAC MOUNT FLASHING TYPE:Unirac FlashLoc - Mill EXISTING SOLAR INFORMATION INVERTER QTY: 1 INVERTER MFG & TYPE : ABB PVI-3.6-OUTD-S-US-Z-A MODULE QTY: 18 MODULE MFG & TYPE: EXISTING PV MODULES BATTERY INFORMATION BATTERY QTY:N/A BATTERY MFG:N/A BATTERY TYPE:N/A 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2019 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2019 CALIFORNIA ELECTRICAL CODE AND 2019 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). GENERAL NOTES · 2019 CALIFORNIA BUILDING CODE · 2019 CALIFORNIA RESIDENTIAL CODE · 2019 CALIFORNIA ELECTRICAL CODE · 2019 CALIFORNIA FIRE CODE · 2019 CALIFORNIA MECHANICAL CODE · 2019 CALIFORNIA GREEN CODE · 2019 CALIFORNIA PLUMBING CODE · 2019 CALIFORNIA ENERGY CODE · ANY OTHER LOCAL AND MUNICIPAL CODES CODE REFERENCES ADDITIONAL SCOPE OF WORK -ADDING AC COMBINER BOX & DERATED (E) 200A MAIN BREAKER TO 175A TO ACCOMODATE FOR BOTH SOLAR SYSTEMS 1 REVISION Updated module layout, module type & module quantity based on As-built Reflected Existing system details Updated roof plan on P3 Updated Placard on P6 Bldg permit #101111217 Elect permit #20176787 - Approved by MS Permits issued on 10/3/22 1402 E 18th St - 2017678710/03/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 OWNER Martin Angel PHONE: 1714-585-0226 EMAIL: martin.angel@ocpw.ocgov.com CONTRACTOR: BETTER EARTH ELECTRIC INC. PHONE: (888)373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: Santa Ana (CA) UTILITY: Southern California Edison DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH ROOF SURFACE: 2696 SQ.FT. PV SQ FOOTAGE: 320.13 SQ.FT. PV COVERAGE: 11.3 % WEIGHT OF EQUIPMENT: 715.35 NO. OF STORIES: FIRE SPRINKLERS: NO LOT INFORMATION APN: 39622131 LOT AREA: 7482 LIVING AREA: 1964 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 12/7/2022 12/7/2022 DATE: TIME: 12:06 PM 12:06 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. PROPERTY INFORMATION Martin Angel 1402 E 18th St, Santa Ana, CA 92705 APN: 39622131 E SYSTEM SIZE: 5925 DC E SYSTEM SIZE: 5000 AC E CEC POWER OUTPUT: 5535 CEC MODULE INFORMATION MODULE QTY: 15 MODULE MFG: Canadian MODULE TYPE: Canadian CS3N-395 INVERTER INFORMATION INVERTER QTY:1 INVERTER MFG:SOLAREDGE INVERTER TYPE:5000H-US Non-RGM POWER OPTIMIZER INFORMATION OPTIMIZER QTY: 15 OPTIMIZER MFG: SOLAREDGE OPTIMIZER TYPE: S440 PROJECT DETAILS COVER SHEET P1 TABLE OF CONTENTS PAGE NUMBER: PAGE TITLE: P1 COVER SHEET P2 SITE PLAN P3 ROOF PLAN P4 RACKING & FRAMING P5 LINE DIAGRAM & DESIGN TABLES P6 PLACARDS & PLACARD MAP P7 OPTIMIZER MAP P8 JOB HAZARD ANALYSIS P9 ELEC. LOAD CALCS SS00 SPECIFICATION PAGES RAILING INFORMATION RAILING MFG:UNIRAC RAILING TYPE:Unirac SM Light MOUNTING INFORMATION MOUNT FLASHING QTY:30 MOUNT FLASHING MFG:UNIRAC MOUNT FLASHING TYPE:Unirac FlashLoc - Mill EXISTING SOLAR INFORMATION INVERTER QTY: 1 INVERTER MFG & TYPE : ABB PVI-3.6-OUTD-S-US-Z-A MODULE QTY: 18 MODULE MFG & TYPE: EXISTING PV MODULES BATTERY INFORMATION BATTERY QTY:N/A BATTERY MFG:N/A BATTERY TYPE:N/A 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2019 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2019 CALIFORNIA ELECTRICAL CODE AND 2019 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). GENERAL NOTES · 2019 CALIFORNIA BUILDING CODE · 2019 CALIFORNIA RESIDENTIAL CODE · 2019 CALIFORNIA ELECTRICAL CODE · 2019 CALIFORNIA FIRE CODE · 2019 CALIFORNIA MECHANICAL CODE · 2019 CALIFORNIA GREEN CODE · 2019 CALIFORNIA PLUMBING CODE · 2019 CALIFORNIA ENERGY CODE · ANY OTHER LOCAL AND MUNICIPAL CODES CODE REFERENCES ADDITIONAL SCOPE OF WORK ADDING AC COMBINER BOX REVISIONS 12.07.22 AS-BUILT. 1 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. REVISED Bldg# 101111217 Elec# 20176787 Issued 10/03/22 Bldg# 101113502 Elec# 20178452 Issued 02/14/23 1402 E 18th St - Revision #2017845202/15/23 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 MM INV INV ACB SCALE: 1/16" = 1' SITE PLAN N (E)200A MAIN SERVICE PANEL (N)SOLAREDGE 5000H-US Non-RGM INVERTER ROOF ACCESS POINT PER CRC 2019 (R324.7.1) ARRAY 3 - (N)6 Canadian MODULES TILT:18° AZIMUTH: 1° EXISTING PV SYSTEM (E) 18 SOLAR PV MODULES 1) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4) THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5) A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA REGULATIONS. 6) MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7) ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8) CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. SITE PLAN ARRAY 2 - (N)7 Canadian MODULES TILT:18° AZIMUTH: 271° ARRAY 1 - (N)2 Canadian MODULES TILT: 18° AZIMUTH: 271° P2 (E) DRIVEWAY (E)PROPERTY LINE Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 9/27/2022 9/27/2022 DATE: TIME: 01:40 pm 01:40 pm PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. CONSTRUCTION NOTES FIRE CODE PATHWAY COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PRODUCTION METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC LOAD CENTER INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4 " EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX LEGEND CALLOUTS PROPERTY LINE INSTALLER NOTES (E) ABB PVI-3.6- OUTD-S-US-Z-A (N) AC COMBINER BOX 1402 E 18th St - 2017678710/03/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 AC MM INV INV SCALE: 1/16" = 1' SITE PLAN N (E) 200A MAIN SERVICE PANEL (N) SOLAREDGE 5000H-US Non-RGM INVERTER ROOF ACCESS POINT PER CRC 2019 (R324.7.1) ARRAY 3 - (N) 6 Canadian MODULES TILT: 18° AZIMUTH: 1° EXISTING PV SYSTEM (E) 18 SOLAR PV MODULES 1) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4) THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5) A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA REGULATIONS. 6) MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7) ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8) CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. SITE PLAN ARRAY 2 - (N) 7 Canadian MODULES TILT: 18° AZIMUTH: 271° ARRAY 1 - (N) 2 Canadian MODULES TILT: 18° AZIMUTH: 271° P2 (E) DRIVEWAY (E) PROPERTY LINE Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 01.27/2023 01.27/2023 DATE: TIME: 07:31 AM 07:31 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. CONSTRUCTION NOTES FIRE CODE PATHWAY COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PRODUCTION METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC LOAD CENTER INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4" EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX LEGEND CALLOUTS PROPERTY LINE INSTALLER NOTES (E) ABB PVI-3.6- OUTD-S-US-Z-A (N) AC COMBINER BOX 2 1402 E 18th St - Revision #2017845202/15/23 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 MM INV IN V AC B Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 9/27/2022 9/27/2022 DATE: TIME: 01:40 pm 01:40 pm PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. SCALE: 3/32" = 1' FIRE CODE PATHWAY N ARRAY 1: MODULE QTY: 2 TILT:18° AZIMUTH:271° MATERIAL:Comp Asphalt Shingles ARRAY 2: MODULE QTY: 7 TILT:18° AZIMUTH:271° MATERIAL:Comp Asphalt Shingles ARRAY 3: MODULE QTY: 6 TILT:18° AZIMUTH:1° MATERIAL:Comp Asphalt Shingles REQUIRED ROOF ACCESS POINT PER CRC 2019 SECTION R324. LADDER ACCESS SHALL BE AT STRONG POINT OF ROOF AND NOT OVER REQUIRED WINDOW OPENINGS. COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PV METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC COMBINER PANEL INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4" EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX ROOF PLAN ROOF PLAN P3 ROOF DETAILS:LEGEND CALLOUTS: INSTALLER NOTES JB 1 6 ' -0 " 6' -0 " 12'-1 0" 6' -0 " 6' -5" 9' -3" DOES NOT HAVE A RAPID SHUTDOWN DEVICE DOES NOT HAVE A RAPID SHUTDOWN DEVICE 1402 E 18th St - 2017678710/03/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 (E) GROUNDING ELECTRODE GROUND ROD STRING 1: (15x) Canadian Canadian CS3N-395 PV MODULES WITH 15 S440 SE POWER OPTIMIZERS 01 JUNCTION BOX - NEMA 3R AS REQUIRED 2 INVERTER SOLAREDGE 5000H-US NON-RGM WITH DC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 3+ - + - + - + - + - + - 1521 DC AC TO UTILITY GRID (Underground) MAX. BREAKER CALC.: 200A X 1.2 - POINT OF INTERCONNECTION LOAD SIDE 705.12(D)(2)(3)(B) MAIN (N) 175A (N) 30A 175A = 65A M BI-DIRECTIONAL UTILITY METER 1PH/240V SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUS BAR FROM THE MAIN BREAKER (E) 200A/175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W 03 NEW AC COMBINER BOX FOR EXISTING AND NEW SOLAR BREAKER(S) JUNCTION BOX NEMA 4 EXISTING PV SYSTEM 18 EXISTING SOLAR PV MODULES WITH ABB PVI-3.6-OUTD-S-US-Z-A INVERTER 1 184 3 2 EXISTING AC DISCONNECT EXISTING INVERTER EXISTING PV SYSTEM TO EXISTING SOLAR PV BREAKER TO EXISTING SOLAR PV SYSTEM (E) 30A (N) 60A CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 1 #10 PV Wire, in open air FREE AIR N/A N/A #6 51 1 15 18.75 40 38.4 90 50 2 #10 THWN-2, in conduit 3/4" EMT 4 N/A #8 51 1 15 18.75 40 38.4 75 35 3 #10 THWN-2, in conduit 3/4" EMT 3 30 #8 32 1 21 26 40 38.4 75 35 4 1 5 6 7 ASHRAE EXTREME LOW DESIGN TEMPERATURES ASHRAE 2% HIGH 32 32 POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS STRING 1 15A 15 380V 21A SYSTEM SUMMARY ARRAY STC POWER 5925W ARRAY PTC POWER 5535W MAX AC CURRENT 30A MAX AC POWER 5000W INVERTER 1 POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY SOLAREDGE S440 Optimizer MAX OUTPUT(A) MAX DC (V) INVERTER 1 SPECS SOLAREDGE 5000H-US_Non-RGM AC VOLTAGE (V) 240 GROUND 0.99 MAX OCPD (A) 30 RATED POWER (W) 5000 MAX OUTPUT (A) 21 MAX INPUT (A) 14 MAX INPUT (V) 480 EFFICIENCY (CEC) 0.99 MODULE SPECS Canadian Canadian CS3N-395MS PMAX (W) 395 PTC (W) 369 ISC (A) 11 IMP (A) 11 VOC (V) 44 VMP (V) 37 TEMP. COEFF. OF VOC -0.122 440 15 98.6 15 60 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 14 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 9/27/2022 9/27/2022 DATE: TIME: 01:40 pm 01:40 pm PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELECTRICAL NOTES 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ALL WORK SHALL COMPLY WITH THE 2019 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. ELECTRICAL LINE DIAGRAM LINE DIAGRAM & DESIGN TABLES P5 DESIGN TABLES #6 THWN-2, in conduit 3/4" EMT 3 #8 4760 75 65 75 65-- 1402 E 18th St - 2017678710/03/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 (E) GROUNDING ELECTRODE GROUND ROD (N) SUB PANEL 240/120 V 1Ø, 3W MAX MAIN BUS: 125A (N) 30 04 STRING 1: (15x) Canadian Canadian CS3N-395 PV MODULES WITH 15 S440 SE POWER OPTIMIZERS 01 JUNCTION BOX - NEMA 3R AS REQUIRED 2A INVERTER SOLAREDGE 5000H-US NON-RGM WITH DC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 3B+ - + - + - + - + - + - 1521 DC AC TO UTILITY GRID (Underground) MAX. BREAKER CALC.: 200A X 1.2 - POINT OF INTERCONNECTION LOAD SIDE 705.12(D)(2)(3)(B) MAIN (E) 175A 175A = 65A M BI-DIRECTIONAL UTILITY METER 1PH/240V (E) 200A/175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W JUNCTION BOX NEMA 4 EXISTING PV SYSTEM 18 EXISTING SOLAR PV MODULES WITH ABB PVI-3.6-OUTD-S-US-Z-A INVERTER 1 184 3 2 EXISTING AC DISCONNECT EXISTING INVERTER EXISTING PV SYSTEM TO EXISTING SOLAR PV BREAKER TO EXISTING SOLAR PV SYSTEM (E) 30A (N) 60A ASHRAE EXTREME LOW DESIGN TEMPERATURES ASHRAE 2% HIGH 32 32 POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS STRING 1 15A 15 380V 21A SYSTEM SUMMARY ARRAY STC POWER 5925W ARRAY PTC POWER 5535W MAX AC CURRENT 30A MAX AC POWER 5000W INVERTER 1 POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY SOLAREDGE S440 Optimizer MAX OUTPUT(A) MAX DC (V) INVERTER 1 SPECS SOLAREDGE 5000H-US_Non-RGM AC VOLTAGE (V) 240 GROUND 0.99 MAX OCPD (A) 30 RATED POWER (W) 5000 MAX OUTPUT (A) 21 MAX INPUT (A) 14 MAX INPUT (V) 480 EFFICIENCY (CEC) 0.99 MODULE SPECS Canadian Canadian CS3N-395MS PMAX (W) 395 PTC (W) 369 ISC (A) 11 IMP (A) 11 VOC (V) 44 VMP (V) 37 TEMP. COEFF. OF VOC -0.122 440 15 98.6 15 60 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 14 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 01.27/2023 01.27/2023 DATE: TIME: 07:31 AM 07:31 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELECTRICAL NOTES 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ALL WORK SHALL COMPLY WITH THE 2019 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. ELECTRICAL LINE DIAGRAM LINE DIAGRAM & DESIGN TABLES P5 DESIGN TABLES 2 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 1 #10 PV Wire, in open air FREE AIR N/A N/A #6 51 1 15 18.75 40 38.4 90 50 2 #10 THWN-2, in conduit 3/4" EMT 2 N/A #8 51 1 15 18.75 40 38.4 75 35 3 #10 THWN-2, in conduit 3/4" EMT 3 30 #8 32 1 21 26 40 38.4 75 35 4 # 6 THWN-2, in conduit 3/4" EMT 3 60 #8 32 1 75 65 75 65 1402 E 18th St - Revision #2017845202/15/23 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 (E) GROUNDING ELECTRODE GROUND ROD STRING 1: (15x) Canadian Canadian CS3N-395 PV MODULES WITH 15 S440 SE POWER OPTIMIZERS 01 JUNCTION BOX - NEMA 3R AS REQUIRED 2A INVERTER SOLAREDGE 5000H-US NON-RGM WITH DC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 3B+ - + - + - + - + - + - 1521 DC AC TO UTILITY GRID (Underground) MAX. BREAKER CALC.: 200A X 1.2 - POINT OF INTERCONNECTION LOAD SIDE 705.12(D)(2)(3)(B) MAIN (E) 175A 175A = 65A M BI-DIRECTIONAL UTILITY METER 1PH/240V SOLAR BREAKER LOCATED AT THE FURTHEST END OF BUS BAR FROM THE MAIN BREAKER (E) 200A/175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W JUNCTION BOX NEMA 4 EXISTING PV SYSTEM 18 EXISTING SOLAR PV MODULES WITH ABB PVI-3.6-OUTD-S-US-Z-A INVERTER 1 184 3 2 EXISTING AC DISCONNECT EXISTING INVERTER EXISTING PV SYSTEM TO EXISTING SOLAR PV BREAKER TO EXISTING SOLAR PV SYSTEM (E) 30A (N) 30A CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 1 #10 PV Wire, in open air FREE AIR N/A N/A #6 51 1 15 18.75 40 38.4 90 50 2 #10 THWN-2, in conduit 3/4" EMT 2 N/A #8 51 1 15 18.75 40 38.4 75 35 3 #10 THWN-2, in conduit 3/4" EMT 3 30 #8 32 1 21 26 40 38.4 75 35 ASHRAE EXTREME LOW DESIGN TEMPERATURES ASHRAE 2% HIGH 32 32 POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS STRING 1 15A 15 380V 21A SYSTEM SUMMARY ARRAY STC POWER 5925W ARRAY PTC POWER 5535W MAX AC CURRENT 30A MAX AC POWER 5000W INVERTER 1 POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY SOLAREDGE S440 Optimizer MAX OUTPUT(A) MAX DC (V) INVERTER 1 SPECS SOLAREDGE 5000H-US_Non-RGM AC VOLTAGE (V) 240 GROUND 0.99 MAX OCPD (A) 30 RATED POWER (W) 5000 MAX OUTPUT (A) 21 MAX INPUT (A) 14 MAX INPUT (V) 480 EFFICIENCY (CEC) 0.99 MODULE SPECS Canadian Canadian CS3N-395MS PMAX (W) 395 PTC (W) 369 ISC (A) 11 IMP (A) 11 VOC (V) 44 VMP (V) 37 TEMP. COEFF. OF VOC -0.122 440 15 98.6 15 60 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 14 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 12/7/2022 12/7/2022 DATE: TIME: 12:06 PM 12:06 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELECTRICAL NOTES 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ALL WORK SHALL COMPLY WITH THE 2019 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. ELECTRICAL LINE DIAGRAM LINE DIAGRAM & DESIGN TABLES P5 DESIGN TABLES 1402 E 18th St - Revision #2017845202/15/23 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION SERVICE BY QUALIFIED PERSONNEL ONLY N Nathan Draeger REV: DESCRIPTION: BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 9/27/2022 9/27/2022 DATE: TIME: 01:40 pm 01:40 pm PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ROOFTOP PV ARRAY UTILITY METER AND MAIN SERVICE PANEL INVERTER YOU ARE HERE PLACARD & PLACARD MAP P6 LABELING PLAN LABEL DIRECTORY 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2.MINIMUM 3/8 INCHES LETTER HEIGHT 3.ALL LETTERS SHALL BE CAPITALIZED 4.ARIAL OR SIMILAR FONT (NON-BOLD) MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS PROPERTY MAP PROPERTY MAP NOTES: INVERTER AC DISCONNECT EXISTING PV PANELS (DOES NOT HAVE A RAPID SHUTDOWN DEVICE) NEW PV PANELS NEW PV PANELS EXISTING PV PANELS (DOES NOT HAVE A RAPID SHUTDOWN DEVICE) BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 STICKER LOCATED INSIDE PANEL NEXT TO PV BREAKER 11 [CEC 690.14(C)(2)] PLACE ON AC DISCONNECT 8 9 [CEC 705.12(B)(2)(3)(C)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. PHOTOVOLTAIC SOLAR BREAKER PHOTOVOLTAIC AC DISCONNECT ! WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 2 3 [CEC 690.53] AT EACH DC DISCONNECT MEANS [CEC 690.5(C)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 [CEC 690.31(G)3 & 4] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' WARNING: PHOTOVOLTAIC POWER SOURCE ! MAXIMUM VOLTAGE PHOTOVOLTAIC SYSTEM DC DISCONNECT ! MAX CIRCUIT CURRENT 15 AMPS ! TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD WARNING MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-DC CONVERTER 4 [CEC 690.12(5)] PLACE ON INVERTER PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 7 6 5 [CEC 690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) [CEC 690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES CEC 705.12(B)(2)(3)(B) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) ! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY WARNING ! RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT ! ! DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONNECTION WARNING 21A 480 VDC 14 AMPS SUB PANEL 5 6 JUNCTION BOX METER MAIN SERVICE PANEL 1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 7 3 5 8 3 5 8 3 5 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WARNING DO NOT UPSIZE MAIN BREAKER BREAKER WAS DOWNSIZED FOR PV SYSTEM D STICKER LOCATED ON MAIN ELECTRICAL PANEL 1402 E 18th St - 2017678710/03/22 Low NMOT: 42 ± 3 °C Low temperature coefficient (Pmax): -0.36 % / °C * As there are different certification requirements in different markets, please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region in which the products are to be used. linear power output warranty* PRODUCT CERTIFICATES* ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety MANAGEMENT SYSTEM CERTIFICATES CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. No. 1 module supplier for quality and performance / price ratio in IHS Module Customer Insight Survey. As a leading PV project developer and manufacturer of solar modules with over 40 GW deployed around the world since 2001. (1000 V / 1500 V) KuMax CS3U-380|385|390|395|400MS HIGH EFFICIENCY MONO PERC MODULE High High PTC rating of up to: 93.24 % CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com Lower hot spot temperature Low power loss in cell connection Minimizes micro-crack impacts MORE POWER Better shading tolerance MORE RELIABLE IEC 61215 / IEC 61730: VDE / CE / CQC / MCS / KS / INMETRO UL 1703 / IEC 61215 performance: CEC listed (US) / FSEC (US Florida) UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE / IEC 60068-2-68: SGS Take-e-way Heavy snow load up to 5400 Pa, wind load up to 3600 Pa* * For detailed information, please refer to the Installation Manual. 5BBMBB *According to the applicable Canadian Solar Limited Warranty Statement. enhanced product warranty on materials and workmanship* 1402 E 18th St - 2017678710/03/22 PARTNER SECTION ELECTRICAL DATA | STC* CS3U 380MS 385MS 390MS 395MS 400MS Nominal Max. Power (Pmax) 380 W 385 W 390 W 395 W 400 W Opt. Operating Voltage (Vmp) 40.0 V 40.2 V 40.4 V 40.6 V 40.8 V Opt. Operating Current (Imp) 9.50 A 9.58 V 9.66 A 9.73 A 9.81 A Open Circuit Voltage (Voc) 47.8 V 48.0 V 48.2 V 48.4 V 48.6 V Short Circuit Current (Isc) 10.01 A 10.09 A10.17 A10.25 A 10.33 A Module Efficiency 19.2% 19.4% 19.7% 19.9% 20.2% Operating Temperature -40°C ~ +85°C Max. System Voltage 1500V (IEC/UL) or 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 1703) or Class C (IEC 61730) Max. Series Fuse Rating 30 A Application Classification Class A Power Tolerance 0 ~ + 10 W * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS3U 380MS 385MS 390MS 395MS 400MS Nominal Max. Power (Pmax) 283 W 287 W 290 W 294 W 298 W Opt. Operating Voltage (Vmp) 37.2 V 37.4 V 37.6 V 37.8 V 38.0 V Opt. Operating Current (Imp) 7.60 A 7.66 A 7.72 A 7.78 A 7.84 A Open Circuit Voltage (Voc) 44.8 V 45.0 V 45.2 V 45.4 V 45.6 V Short Circuit Current (Isc) 8.08 A 8.14 A 8.20 A 8.27 A 8.33 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. MECHANICAL DATA Specification Data Cell Type Mono-crystalline Cell Arrangement 144 [2 X (12 X 6) ] Dimensions 2000 X 992 X 35 mm (78.7 X 39.1 X 1.38 in) Weight 22.5 kg (49.6 lbs) Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy, crossbar enhanced J-Box IP68, 3 bypass diodes Cable 4 mm2 (IEC), 12 AWG (UL) Cable Length (Including Connector) Portrait: 400 mm (15.7 in) (+) / 280 mm (11.0 in) (-); landscape: 1250 mm (49.2 in); leap-frog connection: 1670 mm (65.7 in)* Connector T4 series or H4 UTX or MC4-EVO2 Per Pallet 30 pieces Per Container (40' HQ) 660 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. CS3U-400MS / I-V CURVES CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com ENGINEERING DRAWING (mm) Rear View Frame Cross Section A-A Mounting Hole 950 8-14x9 Mounting hole A A 4-10x7 Mounding hole Grounding hole 6-Ф5 35 40 0 11 5 5 13 0 0 20 0 0 18 0 180 944 992 50 35 35 7 10 R 9 14 R TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient (Pmax)-0.36 % / °C Temperature Coefficient (Voc)-0.29 % / °C Temperature Coefficient (Isc)0.05 % / °C Nominal Module Operating Temperature 42 ± 3°C * The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement. Canadian Solar Inc. reserves the right to make necessary adjustments to the information described he- rein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. May, 2020. All rights reserved, PV Module Product Datasheet V5.61_EN 10 9 8 7 6 5 4 3 2 1 0 V A 10 9 8 7 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 50 V A 5 10 15 20 25 30 35 40 45 50 5°C 25°C 45°C 65°C 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 1111 1402 E 18th St - 2017678710/03/22 INVERTERS so l a r e d g e . c o m Op t i m i z e d i n s t a l l a t i o n w i t h H D - W a v e t e c h n o l o g y Sp e c i fi c a l l y d e s i g n e d t o w o r k w i t h p o w e r o p t i m i z e r s Bu i l t - i n m o d u l e - l e v e l m o n i t o r i n g Op t i o n a l : F a s t e r i n s t a l l a t i o n s w i t h b u i l t - i n co n s u m p t i o n m e t e r i n g ( 1 % a c c u r a c y ) a n d pr o d u c t i o n r e v e n u e g r a d e m e t e r i n g ( 0 . 5 % a c c u r a c y , AN S I C 1 2 . 2 0 ) Re c o r d - b r e a k i n g 9 9 % w e i g h t e d e f fi c i e n c y Qu i c k a n d e a s y i n v e r t e r c o m m i s s i o n i n g d i r e c t l y f r o m a s m a r t p h o n e u s i n g t h e S o l a r E d g e S e t A p p Fi x e d v o l t a g e i n v e r t e r f o r l o n g e r s t r i n g s UL 1 7 4 1 S A c e r t i fi e d , f o r C P U C R u l e 2 1 g r i d c o m p l i a n c e In t e g r a t e d a r c f a u l t p r o t e c t i o n a n d r a p i d s h u t d o w n fo r N E C 2 0 1 4 , N E C 2 0 1 7 a n d N E C 2 0 2 0 p e r a r t i c l e 69 0 . 1 1 a n d 6 9 0 . 1 2 Sm a l l , l i g h t w e i g h t , a n d e a s y t o i n s t a l l b o t h ou t d o o r s o r i n d o o r s Si n g l e P h a s e I n v e r t e r wi t h H D - W a v e T e c h n o l o g y fo r N o r t h A m e r i c a SE 3 0 0 0 H - U S / S E 3 8 0 0 H - U S / S E 5 0 0 0 H - U S / S E 6 0 0 0 H - U S / SE 7 6 0 0 H - U S / S E 1 0 0 0 0 H - U S / S E 1 1 4 0 0 H - U S 1 2 - 2 5 YE A R WA R R A N T Y 1402 E 18th St - 2017678710/03/22 PARTNER SECTION ELECTRICAL DATA | STC* CS3U 380MS 385MS 390MS 395MS 400MS Nominal Max. Power (Pmax) 380 W 385 W 390 W 395 W 400 W Opt. Operating Voltage (Vmp) 40.0 V 40.2 V 40.4 V 40.6 V 40.8 V Opt. Operating Current (Imp) 9.50 A 9.58 V 9.66 A 9.73 A 9.81 A Open Circuit Voltage (Voc) 47.8 V 48.0 V 48.2 V 48.4 V 48.6 V Short Circuit Current (Isc) 10.01 A 10.09 A10.17 A10.25 A 10.33 A Module Efficiency 19.2% 19.4% 19.7% 19.9% 20.2% Operating Temperature -40°C ~ +85°C Max. System Voltage 1500V (IEC/UL) or 1000V (IEC/UL) Module Fire Performance TYPE 1 (UL 1703) or Class C (IEC 61730) Max. Series Fuse Rating 30 A Application Classification Class A Power Tolerance 0 ~ + 10 W * Under Standard Test Conditions (STC) of irradiance of 1000 W/m2, spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA | NMOT* CS3U 380MS 385MS 390MS 395MS 400MS Nominal Max. Power (Pmax) 283 W 287 W 290 W 294 W 298 W Opt. Operating Voltage (Vmp) 37.2 V 37.4 V 37.6 V 37.8 V 38.0 V Opt. Operating Current (Imp) 7.60 A 7.66 A 7.72 A 7.78 A 7.84 A Open Circuit Voltage (Voc) 44.8 V 45.0 V 45.2 V 45.4 V 45.6 V Short Circuit Current (Isc) 8.08 A 8.14 A 8.20 A 8.27 A 8.33 A * Under Nominal Module Operating Temperature (NMOT), irradiance of 800 W/m2, spectrum AM 1.5, ambient temperature 20°C, wind speed 1 m/s. MECHANICAL DATA Specification Data Cell Type Mono-crystalline Cell Arrangement 144 [2 X (12 X 6) ] Dimensions 2000 X 992 X 35 mm (78.7 X 39.1 X 1.38 in) Weight 22.5 kg (49.6 lbs) Front Cover 3.2 mm tempered glass Frame Anodized aluminium alloy, crossbar enhanced J-Box IP68, 3 bypass diodes Cable 4 mm2 (IEC), 12 AWG (UL) Cable Length (Including Connector) Portrait: 400 mm (15.7 in) (+) / 280 mm (11.0 in) (-); landscape: 1250 mm (49.2 in); leap-frog connection: 1670 mm (65.7 in)* Connector T4 series or H4 UTX or MC4-EVO2 Per Pallet 30 pieces Per Container (40' HQ) 660 pieces * For detailed information, please contact your local Canadian Solar sales and technical representatives. CS3U-400MS / I-V CURVES CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com ENGINEERING DRAWING (mm) Rear View Frame Cross Section A-A Mounting Hole 950 8-14x9 Mounting hole A A 4-10x7 Mounding hole Grounding hole 6-Ф5 35 40 0 11 5 5 13 0 0 20 0 0 18 0 180 944 992 50 35 35 7 10 R 9 14 R TEMPERATURE CHARACTERISTICS Specification Data Temperature Coefficient (Pmax)-0.36 % / °C Temperature Coefficient (Voc)-0.29 % / °C Temperature Coefficient (Isc)0.05 % / °C Nominal Module Operating Temperature 42 ± 3°C * The specifications and key features contained in this datasheet may deviate slightly from our actual products due to the on-going innovation and product enhancement. Canadian Solar Inc. reserves the right to make necessary adjustments to the information described he- rein at any time without further notice. Please be kindly advised that PV modules should be handled and installed by qualified people who have professional skills and please carefully read the safety and installation instructions before using our PV modules. May, 2020. All rights reserved, PV Module Product Datasheet V5.61_EN 10 9 8 7 6 5 4 3 2 1 0 V A 10 9 8 7 6 5 4 3 2 1 0 5 10 15 20 25 30 35 40 45 50 V A 5 10 15 20 25 30 35 40 45 50 5°C 25°C 45°C 65°C 1000 W/m2 800 W/m2 600 W/m2 400 W/m2 200 W/m2 1111 1402 E 18th St - Rev #2017926704/18/23 M O D E L N U M B E R SE 3 0 0 0 H - U S SE 3 8 0 0 H - U S SE 5 0 0 0 H - U S SE 6 0 0 0 H - U S SE 7 6 0 0 H - U S SE 1 0 0 0 0 H - U S SE 1 1 4 0 0 H - U S AP P L I C A B L E T O I N V E R T E R S WI T H P A R T N U M B E R SE X X X X H - X X X X X B X X 4 OU T P U T Ra t e d A C P o w e r O u t p u t 30 0 0 38 0 0 @ 2 4 0 V 33 0 0 @ 2 0 8 V 50 0 0 60 0 0 @ 2 4 0 V 50 0 0 @ 2 0 8 V 76 0 0 10 0 0 0 11 4 0 0 @ 2 4 0 V 10 0 0 0 @ 2 0 8 V VA Ma x i m u m A C P o w e r O u t p u t 30 0 0 38 0 0 @ 2 4 0 V 33 0 0 @ 2 0 8 V 50 0 0 60 0 0 @ 2 4 0 V 50 0 0 @ 2 0 8 V 76 0 0 10 0 0 0 11 4 0 0 @ 2 4 0 V 10 0 0 0 @ 2 0 8 V VA AC O u t p u t V o l t a g e M i n . - N o m . - M a x . (2 1 1 - 2 4 0 - 2 6 4 )        Va c AC O u t p u t V o l t a g e M i n . - N o m . - M a x . (1 8 3 - 2 0 8 - 2 2 9 ) -  -  - -  Va c AC F r e q u e n c y ( N o m i n a l ) 59 . 3 - 6 0 - 6 0 . 5 (1 ) Hz Ma x i m u m C o n t i n u o u s O u t p u t Cu r r e n t @ 2 4 0 V 1 2 . 5 1 6 21 25 32 42 47 . 5 A Ma x i m u m C o n t i n u o u s O u t p u t Cu r r e n t @ 2 0 8 V - 1 6 - 24 - - 48 . 5 A Po w e r F a c t o r 1 , A d j u st a b l e - 0 . 8 5 t o 0 . 8 5 GF D I T h r e s h o l d 1 A Ut i l i t y M o n i t o r i n g , I s l a n d i n g P r o t e c t i o n , Co u n t r y C o n fi g u r a b l e T h r e s h o l d s Ye s IN P U T Ma x i m u m D C P o w e r @ 2 4 0 V 46 5 0 59 0 0 77 5 0 93 0 0 11 8 0 0 15 5 0 0 1 7 6 5 0 W Ma x i m u m D C P o w e r @ 2 0 8 V - 51 0 0 - 77 5 0 - - 15 5 0 0 W Tr a n s f o r m e r - l e s s , U n g r o u n d e d Ye s Ma x i m u m I n p u t V o l t a g e 48 0 Vd c No m i n a l D C I n p u t V o l t a g e 38 0 40 0 Vd c Ma x i m u m I n p u t C u r r e n t @ 2 4 0 V (2 ) 8. 5 10 . 5 13 . 5 16 . 5 20 27 30 . 5 Ad c Ma x i m u m I n p u t C u r r e n t @ 2 0 8 V (2 ) - 9 - 13 . 5 - - 27 Ad c Ma x . I n p u t S h o r t C i r c u i t C u r r e n t 45 Ad c Re v e r s e - P o l a r i t y P r o t e c t i o n Ye s Gr o u n d - F a u l t I s o l a t i o n D e t e c t i o n 60 0 k S e n s i t i v i t y Ma x i m u m I n v e r t e r E fficiency 99 99 . 2 % CE C W e i g h t e d E fficiency 99 99 @ 2 4 0 V 98 . 5 @ 2 0 8 V % Ni g h t t i m e P o w e r C o n s u m p t i o n < 2 . 5 W (1 ) F o r o t h e r r e g i o n a l s e t t i n g s p l e a s e c o n t a c t S o l a r E d g e s u p p o r t (2 ) A h i g h e r c u r r e n t s o u r c e m a y b e u s e d ; t h e i n v e r t e r w i l l l i m i t i t s i n p u t c u r r e n t t o t h e v a l u e s st a t e d SE 3 0 0 0 H - U S / S E 3 8 0 0 H - U S / S E 5 0 0 0 H - U S / S E 6 0 0 0 H - U S / SE 7 6 0 0 H - U S / S E 1 0 0 0 0 H - U S / S E 1 1 4 0 0 H - U S Si n g l e P h a s e I n v e r t e r w i t h H D - W a v e T e c h n o l o g y fo r N o r t h A m e r i c a 1402 E 18th St - 2017678710/03/22 IN V E R T E R S solaredge.com Optimized installation with HD-Wave technology Specifically designed to work with power optimizers Built-in module-level monitoring Optional: Faster installations with built-in consumption metering (1% accuracy) and production revenue grade metering (0.5% accuracy, ANSI C12.20) Record-breaking 99% weighted efficiency Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp Fixed voltage inverter for longer strings UL1741 SA certified, for CPUC Rule 21 grid compliance Integrated arc fault protection and rapid shutdown for NEC 2014, NEC 2017 and NEC 2020 per article 690.11 and 690.12 Small, lightweight, and easy to install both outdoors or indoors Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US / SE11400H-US 12-25 YEAR WARRANTY 1402 E 18th St - Rev #2017926704/18/23 MO D E L N U M B E R SE 3 0 0 0 H - U S SE 3 8 0 0 H - U S SE 5 0 0 0 H - U S SE 6 0 0 0 H - U S SE 7 6 0 0 H - U S SE 1 0 0 0 0 H - U S SE 1 1 4 0 0 H - U S AD D I T I O N A L F E A T U R E S Su p p o r t e d C o m m u n i c a t i o n I n t e r f a c e s RS 4 8 5 , E t h e r n e t , Z i g B e e ( o p t i o n a l ) , C e l l u l a r ( o p t i o n a l ) Re v e n u e G r a d e M e t e r i n g , A N S I C 1 2 . 2 0 Op t i o n a l (3 ) Co n s u m p t i o n m e t e r i n g In v e r t e r C o m m i s s i o n i n g Wi t h t h e S e t A p p m o b i l e a p p l i c a t i o n u s i n g B u i l t - i n W i - F i A c c e s s P o i n t f o r L o c a l C o n n e c t i o n Ra p i d S h u t d o w n - N E C 2 0 1 4 , N E C 20 1 7 a n d N E C 2 0 2 0 , 6 9 0 . 1 2 Au t o m a t i c R a p i d S h u t d o w n u p o n A C G r i d D i s c o n n e c t ST A N D A R D C O M P L I A N C E Sa f e t y UL 1 7 4 1 , U L 1 7 4 1 S A , U L 1 6 9 9 B , C S A C 2 2 . 2 , C a n a d i a n A F C I a c c o r d i n g t o T . I . L . M - 0 7 Gr i d C o n n e c t i o n S t a n d a r d s IE E E 1 5 4 7 , R u l e 2 1 , R u l e 1 4 ( H I ) Em i s s i o n s FC C P a r t 1 5 C l a s s B IN S T A L L A T I O N S P E C I F I C A T I O N S AC O u t p u t C o n d u i t S i z e / A W G R a n g e 1' ' M a x i m u m / 1 4 - 6 A W G 1' ' M a x i m u m / 1 4 - 4 A W G DC I n p u t C o n d u i t S i z e / # o f S t r i n g s / AW G R a n g e 1' ' M a x i m u m / 1 - 2 st r i n g s / 1 4 - 6 A W G 1' ' M a x i m u m / 1 - 3 st r i n g s / 1 4 - 6 A W G Di m e n s i o n s w i t h S a f e t y S w i t c h ( H x W x D ) 17 . 7 x 1 4 . 6 x 6 . 8 / 4 5 0 x 3 7 0 x 1 7 4 21 . 3 x 1 4 . 6 x 7 . 3 / 5 4 0 x 3 7 0 x 1 8 5 in / m m We i g h t w i t h S a f e t y S w i t c h 22 / 1 0 25 . 1 / 1 1 . 4 26 . 2 / 1 1 . 9 38 . 8 / 1 7 . 6 lb / k g No i s e < 2 5 <5 0 dB A Co o l i n g Na t u r a l C o n v e c t i o n Op e r a t i n g T e m p e r a t u r e R a n g e -4 0 t o + 1 4 0 / - 4 0 t o + 6 0 (4 ) ˚F / ˚ C Pr o t e c t i o n R a t i n g NE M A 4 X ( I n v e r t e r w i t h S a f e t y S w i t c h ) (3 ) I n v e r t e r w i t h R e v e n u e G r a d e M e t e r P / N : S E x x x x H - U S 0 0 0 B N C 4 ; I n v e r t e r w i t h R e v e n u e G r a d e P r o d u c t i o n a n d C o n s u m p t i o n M e t e r P / N : S E x x x x H - U S 0 0 0 B N I 4 . F o r c o n s u m p t i o n m e t e r i n g , c u r r e n t t r a n s f o r m e r s sh o u l d b e o r d e r e d s e p a r a t e l y : S E A C T 0 7 5 0 - 2 0 0 N A - 2 0 o r S E A C T 0 7 5 0 - 4 0 0 N A - 2 0 . 2 0 u n i t s p e r b o x (4 ) F u l l p o w e r u p t o a t l e a st 5 0 ˚ C / 1 2 2 ˚ F ; f o r p o w e r d e - r a t i n g i n f o r m a t i o n r e f e r t o : h t t p s : / / w w w . s o l a r e d g e . c o m / s i t e s / d e f a u l t / fi l e s / s e - t e m p e r a t u r e - d e r a t i n g - n o t e - n a . p d f Si n g l e P h a s e I n v e r t e r w i t h H D - W a v e T e c h n o l o g y fo r N o r t h A m e r i c a SE 3 0 0 0 H - U S / S E 3 8 0 0 H - U S / S E 5 0 0 0 H - U S / S E 6 0 0 0 H - U S / SE 7 6 0 0 H - U S / S E 1 0 0 0 0 H - U S / S E 1 1 4 0 0 H - U S Ho w t o E n a b l e C o n s u m p t i o n M o n i t o r i n g By s i m p l y w i r i n g c u r r e n t t r a n s f o r m e r s t h r o u g h t h e i n v e r t e r ' s e x i s t i n g A C c o n d u i t s a n d c o n n e c t i n g t h e m t o t h e s e r v i c e pa n e l , h o m e o w n e r s w i l l g a i n f u l l i n s i g h t i n t o t h e i r h o u s e h o l d e n e r g y u s a g e h e l p i n g t h e m t o a v o i d h i g h e l e c t r i c i t y b i l l s © S o l a r E d g e T e c h n o l o g i e s , I n c . A l l r i g h t s r e s e r v e d . S O L A R E D G E , t h e S o l a r E d g e l o g o , O P T I M I Z E D B Y S O L A R E D G E a r e t r a d e m a r k s o r r e g i s t e r e d t r a d e m a r k s o f S o l a r E d g e T e c h n o l o g i e s , I n c . A l l ot h e r t r a d e m a r k s m e n t i o n e d h e r e i n a r e t r a d e m a r k s o f t h e i r r e s p e c t i v e o w n e r s . D a t e : 1 2 / 2 0 2 0 / V 0 1 / E N G N A M . S u b j e c t t o c h a n g e w i t h o u t n o t i c e . 1402 E 18th St - 2017678710/03/22 MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US APPLICABLE TO INVERTERS WITH PART NUMBER SEXXXXH-XXXXXBXX4 OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA Maximum AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 11400 @ 240V 10000 @ 208V VA AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264)Vac AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229)- - - -Vac AC Frequency (Nominal)59.3 - 60 - 60.5(1)Hz Maximum Continuous Output Current @240V 12.5 16 21 25 32 42 47.5 A Maximum Continuous Output Current @208V -16 -24 --48.5 A Power Factor 1, Adjustable - 0.85 to 0.85 GFDI Threshold 1 A Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes INPUT Maximum DC Power @240V 4650 5900 7750 9300 11800 15500 17650 W Maximum DC Power @208V -5100 -7750 --15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current @240V(2)8.5 10.5 13.5 16.5 20 27 30.5 Adc Maximum Input Current @208V(2)-9 -13.5 --27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600k Sensitivity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 99 @ 240V 98.5 @ 208V % Nighttime Power Consumption < 2.5 W (1) For other regional settings please contact SolarEdge support (2) A higher current source may be used; the inverter will limit its input current to the values stated SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US Single Phase Inverter with HD-Wave Technology for North America 1402 E 18th St - Rev #2017926704/18/23 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents ƒ Rapid shutdown cables ƒ Micro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals. Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. DC connection terminals Disconnect here Disconnect here Switch terminal block Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): ƒ If the cables at the top are red and black from left to right, connect as shown below. Figure 2: Rapid shutdown cable connected – option 1 ƒ If the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected – option 2 6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. Red (+) Black (-) Black (-) DC+ DC- Red (+) with rapid shutdown resistor Black (-) Red (+) Black (-) BlaRed (+) with rapid shutdown resistor DC+ DC- 1402 E 18th St - 2017678710/03/22 MODEL NUMBER SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US SE11400H-US ADDITIONAL FEATURES Supported Communication Interfaces RS485, Ethernet, ZigBee (optional), Cellular (optional) Revenue Grade Metering, ANSI C12.20 Optional(3) Consumption metering Inverter Commissioning With the SetApp mobile application using Built-in Wi-Fi Access Point for Local Connection Rapid Shutdown - NEC 2014, NEC 2017 and NEC 2020, 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connection Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 1'' Maximum / 14-6 AWG 1'' Maximum /14-4 AWG DC Input Conduit Size / # of Strings / AWG Range 1'' Maximum / 1-2 strings / 14-6 AWG 1'' Maximum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD)17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convection Operating Temperature Range -40 to +140 / -40 to +60(4)˚F / ˚C Protection Rating NEMA 4X (Inverter with Safety Switch) (3) Inverter with Revenue Grade Meter P/N: SExxxxH-US000BNC4; Inverter with Revenue Grade Production and Consumption Meter P/N: SExxxxH-US000BNI4 . For consumption metering, current transformers should be ordered separately: SEACT0750-200NA-20 or SEACT0750-400NA-20. 20 units per box (4) Full power up to at least 50˚C / 122˚F; for power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note-na.pdf Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US / SE11400H-US How to Enable Consumption Monitoring By simply wiring current transformers through the inverter's existing AC conduits and connecting them to the service panel, homeowners will gain full insight into their household energy usage helping them to avoid high electricity bills © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 12/2020/V01/ENG NAM. Subject to change without notice. 1402 E 18th St - Rev #2017926704/18/23 Po w e r O p t i m i z e r Fo r R e s i d e n t i a l I n s t a l l a t i o n s S4 40, S 5 0 0 25 YE A R WA R R A N T Y En a b l i n g PV p o w e r o p t i m i z a t i o n a t t h e m o d u l e l e v e l Sp e c i f i c a l l y d e s i g n e d t o w o r k w i t h S o l a r E d g e re s i d e n t i a l i n v e r t e r s De t e c t s a b n o r m a l P V c o n n e c t o r b e h a v i o r , pr e v e n t i n g p o t e n t i a l s a f e t y i s s u e s * Mo d u l e - l e v e l v o l t a g e s h u t d o w n f o r i n s t a l l e r a n d fi r e f i g h t e r s a f e t y Su p e r i o r e f f i c i e n c y ( 9 9 . 5 % ) Mi t i g a t e s a l l t y p e s o f m o d u l e m i s m a t c h l o s s , f r o m ma n u f a c t u r i n g t o l e r a n c e t o p a r t i a l s h a d i n g Fa s t e r i n s t a l l a t i o n s w i t h s i m p l i f i e d c a b l e ma n a g e m e n t a n d e a s y a s s e m b l y u s i n g a s i n g l e b o l t Fl e x i b l e s y s t e m d e s i g n f o r m a x i m u m s p a c e u t i l i z a t i o n Co m p a t i b l e w i t h b i f a c i a l P V m o d u l e s * Fu n c t i o n a l i t y s u b j e c t t o i n v e r t e r m o d e l a n d f i r m w a r e v e r s i o n so l a r e d g e . c o m POWER OPTIMIZER 1402 E 18th St - 2017678710/03/22 Rapid Shutdown Kit Installation - MAN-01-00186-1.6 1 Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) This document describes how to install the rapid shutdown kit in the SolarEdge Safety Switch, and how to enable the rapid shutdown feature in the inverter in order to provide the functionality described in the Rapid Shutdown clause of NEC2014 690.12 (1) through (4). Kit Contents ƒ Rapid shutdown cables ƒMicro-SD card and SD card adapter with firmware files (Note: DO NOT THROW AWAY THE CARD AND THE ADAPTER; keep them for installation of other rapid shutdown kits) Cable Installation Perform this procedure before connecting the strings to the Safety Switch [Chapter 4: Connecting the AC and the Strings to the Safety Switch in the SolarEdge Installation Guide]. 1 Turn the inverter ON/OFF switch to OFF. If installing the kit in an inverter that is already operating, wait until the LCD indicates that the DC voltage is safe (<50V), or wait five minutes before continuing to the next step. 2 Turn the Safety Switch and the AC switch on the main circuit board to OFF. WARNING! If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five minutes for the input capacitors of the inverter to discharge. 3 Loosen the four Allen screws on the front cover of the Safety Switch, and open the cover. 4 Carefully disconnect the two DC cables from the left side of the switch and from the DC connection spring clamp terminals, as illustrated below1. Use a standard straight-bladed screwdriver to disconnect the cables from the terminals. Figure 1: Inside the AC/DC Safety Switch 1 The internal components may vary depending on the Safety Switch model; the figures in this documents show the AC/DC Safety Switch for single phase 7.6-11.4 kW inverters. DC connection terminals Disconnect here Disconnect here Switch terminal block Rapid Shutdown Kit - Installation and Configuration (Single Phase Inverters) Rapid Shutdown Kit Installation - MAN-01-00186-1.6 2 5 The rapid shutdown cables have a resistor connected to one end (on the red cable). Connect these ends to the switch, making sure that the red and black cables are reversed relative to the cables connected at the top of the switch (going into the DC side conduit between the inverter and the Safety Switch), as detailed below. Apply a torque of 2 N*m (18 lb*in): ƒ If the cables at the top are red and black from left to right, connect as shown below. Figure 2: Rapid shutdown cable connected – option 1 ƒIf the cables at the top are black and red from left to right, connect as shown below. Figure 3: Rapid shutdown cable connected – option 2 6 Use a standard straight-bladed screwdriver to connect the other end of the rapid shutdown cables to the DC connection spring-clamp terminals: Connect the black cable from the switch to the DC- terminal block, and connect the red cable from the switch to the DC+ terminal block. 7 Check that the cables are located and connected in the correct positions to ensure the rapid shutdown functionality. 8 Close the cover: Attach the switch cover and secure it by tightening the four screws with a torque of 0.9 ft.*lb / 1.2 N*m. Red (+) Black (-) Black (-) DC+ DC- Red (+) with rapid shutdown resistor Black (-) Red (+) Black (-)BlaRed (+) with rapid shutdown resistor DC+ DC- 1402 E 18th St - Rev #2017926704/18/23 Po w e r O p t i m i z e r For R e s i d e n t i a l I n s t a l l a t i o n s S4 40, S 5 0 0 S4 40 S5 0 0 UN I T Ra t e d I n p u t D C P o w e r (1 ) 440 50 0 W Ab s o l u t e M a x i m u m I n p u t V o l t a g e ( V o c ) 60 Vd c MP P T O p e r a t i n g R a n g e 8 - 6 0 Vd c Ma x i m u m S h o r t C i r c u i t C u r r e n t ( I s c ) o f C o n n e c t e d P V M o d u l e 14 . 5 Ad c Ma x i m u m E f f i c i e n c y 99 . 5 % We i g h t e d E f f i c i e n c y 98 . 6 % Ov e r v o l t a g e C a t e g o r y II OU T P U T D U R I N G O P E R A T I O N Ma x i m u m O u t p u t C u r r e n t 15 Ad c Ma x i m u m O u t p u t V o l t a g e 60 Vd c OU T P U T D U R I N G S T A N D B Y (PO W E R O P T I M I Z E R D I S C O N N E C T E D F R O M I N V E R T E R O R I N V E R T E R O F F ) Sa f e t y O u t p u t V o l t a g e p e r P o w e r O p t i m i z e r 1 Vd c ST A N D A R D C O M P L I A N C E EM C FC C P a r t 1 5 C l a s s B , I E C 6 1 0 0 0 - 6 - 2 , I E C 6 1 0 0 0 - 6 - 3 , CI S P R 1 1 , E N - 5 5 0 1 1 Sa f e t y IE C 6 2 1 0 9 - 1 ( c l a s s I I s a f e t y ) , U L 1 7 4 1 Ma t e r i a l UL 9 4 V - 0 , U V R e s i s t a n t Ro H S Ye s Fi r e S a f e t y VD E - A R - E 2 1 0 0 - 7 1 2 : 2 0 1 3 - 0 5 IN S T A L L A T I O N S P E C I F I C A T I O N S Ma x i m u m A l l o w e d S y s t e m V o l t a g e 10 0 0 Vd c Di m e n s i o n s ( W x L x H ) 12 9 x 1 5 5 x 3 0 mm We i g h t ( i n c l u d i n g c a b l e s ) 65 5 / 1 . 5 gr / l b In p u t C o n n e c t o r MC 4 (2 ) In p u t W i r e L e n g t h 0. 1 m Ou t p u t C o n n e c t o r MC 4 Ou t p u t W i r e L e n g t h (+ ) 2 . 3 , ( - ) 0 . 1 0 m Op e r a t i n g T e m p e r a t u r e R a n g e (3 ) -4 0 t o + 8 5 ˚C Pr o t e c t i o n R a t i n g IP 6 8 / N E M A 6 P Re l a t i v e H u m i d i t y 0 - 1 0 0 % (1 ) Ra t e d p o w e r o f t h e m o d u l e a t S T C w i l l n o t e x c e e d t h e Pow e r Opt i m i z e r R a t e d I n p u t D C P o w e r . M o d u l e s w i t h u p t o + 5 % p o w e r t o l e r a n c e a r e a l l o w e d (2 ) Fo r o t h e r c o n n e c t o r t y p e s p l e a s e c o n t a c t S o l a r E d g e (3 ) Fo r a m b i e n t t e m p e r a t u r e a b o v e + 7 0 ° C / + 1 5 8 ° F p o w e r d e - r a t i n g i s a p p l i e d . R e f e r t o P o w e r O p t i m i z e r s T e m p e r a t u r e D e - R a t i n g T e c h n i c a l N o t e f o r m o r e d e t a i l s (4 ) If t h e i n v e r t e r s r a t e d A C p o w e r ≤ m a x i m u m n o m i n a l p o w e r p e r s t r i n g , t h e n t h e m a x i m u m p o w e r p e r s t r i n g w i l l b e a b l e t o r e a c h u p t o t h e i n v e r t e r s m a x i m u m i n p u t D C po w e r Re f e r t o : h t t p s : / / w w w . s o l a r e d g e . c o m / s i t e s / d e f a u l t / f i l e s / s e - p o w e r - o p t i m i z e r - s i n g l e - s t r i n g - d e s i g n - a p p l i c a t i o n - n o t e . p d f (5 ) Fo r t h e 2 3 0 / 4 0 0 V g r i d : i t i s a l l o w e d t o i n s t a l l u p t o 1 3 , 5 0 0 W p e r s t r i n g w h e n t h e m a x i m u m p o w e r d i f f e r e n c e b e t w e e n e a c h s t r i n g i s 2 , 0 0 0 W (6 ) Fo r t h e 2 7 7 / 4 8 0 V g r i d : i t i s a l l o w e d t o i n s t a l l u p t o 1 5 , 0 0 0 W p e r s t r i n g w h e n t h e m a x i m u m p o w e r d i f f e r e n c e b e t w e e n e a c h s t r i n g i s 2 , 0 0 0 W (7 ) It i s n o t a l l o w e d t o m i x S - s e r i e s a n d P - s e r i e s Pow e r Opt i m i z e r s i n n e w i n s t a l l a t i o n s © S o l a r E d g e T e c h n o l o g i e s , I n c . A l l r i g h t s r e s e r v e d . S O L A R E D G E , t h e S o l a r E d g e l o g o , O P T I M I Z E D B Y S O L A R E D G E a r e t r a d e m a r k s o r r e g i s t e r e d t r a d e m a r k s o f S o l a r E d g e T e c h n o l o g i e s , I n c . Al l ot h e r tr a d e m a r k s m e n t i o n e d he r e i n ar e t r a d e m a r k s of th e i r r e s p e c t i v e ow n e r s . Da t e : 1 2 /2 0 2 1 DS - 0 0 0 0 91 -1 . 2-EN G . S u b j e c t to ch a n g e w i t h o u t no t i c e . PV S y s t e m D e s i g n U s i n g a S o l a r E d g e In v e r t e r Si n g l e P h a s e HD - W a v e Th r e e P h a s e Th r e e P h a s e f o r 27 7 / 4 8 0 V G r i d Mi n i m u m S t r i n g L e n g t h (P o w e r O p t i m i z e r s ) S4 4 0 , S 5 0 0 8 16 1 8 Ma x i m u m S t r i n g L e n g t h ( P o w e r O p t i m i z e r s ) 25 50 Ma x i m u m N o m i n a l P o w e r p e r S t r i n g (4 ) 57 0 0 11 2 5 0 (5 ) 12 7 5 0 (6 ) W Pa r a l l e l S t r i n g s o f D i f f e r e n t L e n g t h s o r O r i e n t a t i o n s Ye s 15 1402 E 18th St - 2017678710/03/22 solaredge.com Power Optimizer For Residential Installations S440 / S500 / S500B Enabling PV power optimization at the module level Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module-level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt Flexible system design for maximum space utilization Compatible with bifacial PV modules PO W E R O P T I M I Z E R 2 5 YEAR WARRANTY * Functionality subject to inverter model and firmware version 1402 E 18th St - Rev #2017926704/18/23 FL A S H LO C i s t h e u l t i m a t e a t t a c h m e n t f o r c o m p o s i t i o n s h i n g l e a n d r o l l e d c o m p r o o f s . T h e a l l - i n - o n e m o u n t i n s t a l l s fa s t — n o k n e e l i n g o n h o t r o o f s t o i n s t a l l fl a s h i n g , n o p r y i n g o r c u t t i n g s h i n g l e s , n o p u l l i n g n a i l s . S i m p l y d r i v e t h e la g b o l t a n d i n j e c t s e a l a n t i n t o t h e b a s e . FL A S H LO C ’ s p a t e n t e d T R I P L E S E A L t e c h n o l o g y p r e s e r v e s t h e r o o f a n d pr o t e c t s t h e p e n e t r a t i o n w i t h a p e r m a n e n t p r e s s u r e s e a l . K i t t e d w i t h l a g b o l t s , s e a l a n t , a n d h a r d w a r e f o r m a x i m u m co n v e n i e n c e . D o n ’ t j u s t d i v e r t w a t e r , L O C i t o u t ! PR O T E C T T H E R O O F In s t a l l a h i g h - s t r e n g t h w a t e r p r o o f a t t a c h m e n t wi t h o u t l i f t i n g , p r y i n g o r d a m a g i n g s h i n g l e s . FL A S H LO C LO C O U T W A T E R Wi t h a n o u t e r s h i e l d 1 co n t o u r - c o n f o r m i n g g a s k e t 2 a n d p r e s s u r i z e d s e a l a n t c h a m b e r 3 t h e T r i p l e S e a l te c h n o l o g y d e l i v e r s a 1 0 0 % w a t e r p r o o f c o n n e c t i o n . Cu t A w a y V i e w HI G H - S P E E D I N S T A L L Si m p l y d r i v e l a g b o l t a n d i n j e c t s e a l a n t i n t o t h e p o r t 4 to c r e a t e a p e r m a n e n t p r e s s u r e s e a l . Cu t A w a y V i e w FA S T E R I N S T A L L A T I O N . 2 5 - Y E A R W A R R A N T Y . F O R Q U E S T I O N S O R C U S T O M E R S E R V I C E V I S I T U N I R A C . C O M O R C A L L ( 5 0 5 ) 2 4 8 - 2 7 0 2 3 2 4 1 TE S T E D T O T A S - 1 0 0 WI N D D R I V E N R A I N T E S T AN D U L 4 4 1 R A I N T E S T 1402 E 18th St - 2017678710/03/22 © SolarEdge Technologies, Ltd. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: September 22, 2022 DS-000091-ENG. Subject to change without notice. Power Optimizer For Residential Installations S440 / S500 / S500B S440 S500 S500B UNIT INPUT Rated Input DC Power(1)440 500 W Absolute Maximum Input Voltage (Voc)60 125 Vdc MPPT Operating Range 8 – 60 12.5 – 105 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14.5 15 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc STANDARD COMPLIANCE(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPR11, EN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 155 x 45 mm Weight (including cables) 655 gr Input Connector MC4(3) Input Wire Length 0.1 m Output Connector MC4 Output Wire Length (+) 2.3, (-) 0.10 m Operating Temperature Range(4) -40 to +85 ˚C Protection Rating IP68 Relative Humidity 0 – 100 % (1) Rated power of the module at STC will not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity – CE. (3) For other connector types please contact SolarEdge. (4) For ambient temperature above +70°C power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Technical Note for details. PV System Design Using a SolarEdge Inverter(5) SolarEdge Home Wave Single Phase Three Phase SExxK-RWB Three Phase for 230/400V Grid Three Phase for 277/480V Grid Minimum String Length (Power Optimizers) S440, S500 8 9 16 18 S500B 6 8 14 Maximum String Length (Power Optimizers )25 20 50 Maximum Continuous Power per String 5700 5625 11250 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings is less than 2,000W) See(6)See(6)13500 15000 W Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimizers in new installations. (6) If the inverter’s rated AC power ≤ maximum nominal power per string, then the maximum power per string will be able to reach up to the inverters maximum input DC power. Refer to Application Note: Single String Design Guidelines. * 45mm for S500B 1402 E 18th St - Rev #2017926704/18/23 FA S T E R I N S T A L L A T I O N . 2 5 - Y E A R W A R R A N T Y . F O R Q U E S T I O N S O R C U S T O M E R S E R V I C E V I S I T U N I R A C . C O M O R C A L L ( 5 0 5 ) 2 4 8 - 2 7 0 2 FL A S H LO C IN S T A L L A T I O N G U I D E ST E P 1 : S E C U R E Pl a c e FL A S H LO C o v e r p i l o t h o l e w i t h l a g o n d o w n - s l o p e s i d e . A l i g n i n d i c a t o r m a r k s o n s i d e s o f mo u n t w i t h c h a l k l i n e . P a s s i n c l u d e d l a g b o l t a n d s e a l i n g w a s h e r t h r o u g h FL A S H LO C i n t o p i l o t ho l e . D r i v e l a g b o l t u n t i l m o u n t i s h e l d fi r m l y i n p l a c e . NO T E : Th e E P D M i n t h e s e a l i n g w a s h e r w i l l e x p a n d b e y o n d t h e e d g e o f t h e m e t a l w a s h e r w h e n pr o p e r t o r q u e i s a p p l i e d . PR E - I N S T A L L Sn a p c h a l k l i n e s f o r a t t a c h m e n t r o w s . O n s h i n g l e r o o f s , s n a p l i n e s 1 - 3 / 4 ” b e l o w u p s l o p e e d g e of s h i n g l e c o u r s e . L o c a t e r a f t e r s a n d m a r k a t t a c h m e n t l o c a t i o n s . At e a c h l o c a t i o n , d r i l l a 7 / 3 2 ” p i l o t h o l e . C l e a n r o o f s u r f a c e o f d i r t , d e b r i s , s n o w , a n d i c e . Ne x t , B A C K F I L L A L L P I L O T H O L E S W I T H S E A L A N T . NO T E : Sp a c e m o u n t s p e r r a c k i n g s y s t e m i n s t a l l s p e c i fi c a t i o n s . ST E P 2 : S E A L In s e r t t i p o f U N I R A C p r o v i d e d s e a l a n t i n t o p o r t . I n j e c t u n t i l s e a l a n t e x i t s b o t h v e n t s . Co n t i n u e a r r a y i n s t a l l a t i o n , a t t a c h i n g r a i l s t o m o u n t s w i t h p r o v i d e d T - b o l t s . NO T E : Wh e n FL A S H LO C i s i n s t a l l e d o v e r g a p b e t w e e n s h i n g l e t a b s o r v e r t i c a l j o i n t s , fil l g a p / j o i n t w i t h s e a l a n t b e t w e e n m o u n t a n d u p s l o p e e d g e o f s h i n g l e c o u r s e . NO T E : Wh e n i n s t a l l i n g i n c l u d e d r a i l a t t a c h m e n t h a r d w a r e , t o r q u e n u t t o 3 0 f t / l b s . US E O N L Y U N I R A C A P P R O V E D S E A L A N T S : Ch e m l i n k D u r a l i n k 5 0 ( i n c l u d e d i n k i t ) o r C h e m l i n k M - 1 SE A L A N T GA P 1. 7 5 " 1402 E 18th St - 2017678710/03/22 FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with lag bolts, sealant, and hardware for maximum convenience. Don’t just divert water, LOC it out! PROTECT THE ROOF Install a high-strength waterproof attachment without lifting, prying or damaging shingles. FLASH LOC LOC OUT WATER With an outer shield 1 contour-conforming gasket 2 and pressurized sealant chamber 3 the Triple Seal technology delivers a 100% waterproof connection. Cut Away View HIGH-SPEED INSTALL Simply drive lag bolt and inject sealant into the port 4 to create a permanent pressure seal. Cut Away View FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 3 2 4 1 TESTED TO TAS-100 WIND DRIVEN RAIN TEST AND UL441 RAIN TEST 1402 E 18th St - Rev #2017926704/18/23 LE G A L N O T I C E DR A W I N G N O T T O S C A L E AL L D I M E N S I O N S A R E NO M I N A L PR O D U C T P R O T E C T E D B Y ON E O R M O R E U S P A T E N T S SO L A R M O U N T PA R T D R A W I N G 4/ 2 8 / 2 0 2 0 FL A S H L O C C O M P K I T RE V I S I O N D A T E : DR A W I N G T Y P E : DE S C R I P T I O N : FL-A01 PR O D U C T L I N E : 14 1 1 B R O A D W A Y B L V D . N E AL B U Q U E R Q U E , N M 8 7 1 0 2 U S A PH O N E : 5 0 5 . 2 4 2 . 6 4 1 1 WW W . U N I R A C . C O M SH E E T PA R T T A B L E P/ N DE S C R I P T I O N 00 4 0 8 5 M FL A S H L O C C O M P K I T M I L L , 2 0 P A C K 00 4 0 8 5 D FL A S H L O C C O M P K I T D A R K , 2 0 P A C K 67 8" 312 " 33 4" 214 " 5/ 1 6 " x 4 " S S L A G B O L T W/ S S E P D M B O N D E D W A S H E R SS S E R R A T E D T - B O L T FL A S H L O C B A S E MI L L O R D A R K SS S E R R A T E D F L A N G E N U T 1402 E 18th St - 2017678710/03/22 FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 FLASH LOC INSTALLATION GUIDE STEP 1: SECURE Place FLASHLOC over pilot hole with lag on down-slope side. Align indicator marks on sides of mount with chalk line. Pass included lag bolt and sealing washer through FLASHLOC into pilot hole. Drive lag bolt until mount is held firmly in place. NOTE: The EPDM in the sealing washer will expand beyond the edge of the metal washer when proper torque is applied. PRE-INSTALL Snap chalk lines for attachment rows. On shingle roofs, snap lines 1-3/4” below upslope edge of shingle course. Locate rafters and mark attachment locations. At each location, drill a 7/32” pilot hole. Clean roof surface of dirt, debris, snow, and ice. Next, BACKFILL ALL PILOT HOLES WITH SEALANT. NOTE: Space mounts per racking system install specifications. STEP 2: SEAL Insert tip of UNIRAC provided sealant into port. Inject until sealant exits both vents. Continue array installation, attaching rails to mounts with provided T-bolts. NOTE: When FLASHLOC is installed over gap between shingle tabs or vertical joints, fill gap/joint with sealant between mount and upslope edge of shingle course. NOTE: When installing included rail attachment hardware, torque nut to 30 ft/lbs. USE ONLY UNIRAC APPROVED SEALANTS: Chemlink Duralink 50 (included in kit) or Chemlink M-1 SEALANT GAP 1.75" 1402 E 18th St - Rev #2017926704/18/23 SO L A R MO U N T i s t h e p r o f e s s i o n a l s ’ c h o i c e f o r r e s i d e n t i a l P V m o u n t i n g a p p l i c a t i o n s . E v e r y a s p e c t o f t h e sy s t e m i s d e s i g n e d f o r a n e a s i e r , f a s t e r i n s t a l l a t i o n e x p e r i e n c e . SO L A R MO U N T i s a c o m p l e t e s o l u t i o n w i t h re v o l u t i o n a r y u n i v e r s a l c l a m p s , FL A S H K I T P R O , f u l l s y s t e m U L 2 7 0 3 c e r t i f i c a t i o n a n d 2 5 - y e a r w a r r a n t y . N o t on l y i s SO L A R MO U N T e a s y t o i n s t a l l , b u t b e s t - i n - c l a s s a e s t h e t i c s m a k e i t t h e m o s t a t t r a c t i v e o n a n y b l o c k ! NO W F E A T U R I N G F L A S H K I T P R O Th e C o m p l e t e R o o f A t t a c h m e n t S o l u t i o n NO W W I T H U N I V E R S A L M I D C L A M P S Ac c o m m o d a t e s 3 0 m m - 5 1 m m m o d u l e f r a m e s On e t o o l , o n e - p e r s o n i n s t a l l s a r e h e r e ! RE V O L U T I O N A R Y N E W E N D C L A M P S Co n c e a l e d d e s i g n a n d i n c l u d e d E n d C a p s TH E P R O F E S S I O N A L S ’ C H O I C E F O R R E S I D E N T I A L R A C K I N G B E S T I N S T A L L A T I O N E X P E R I E N C E • C U R B A P P E A L • C O M P L E T E S O L U T I O N • U N I R A C S U P P O R T SO L A R M O U N T OP T I O N A L FR O N T T R I M Ne w & I m p r o v e d : TH E P R O F E S S I O N A L S ’ C H O I C E Wi t h S u p e r i o r A e s t h e t i c s CO N C E A L E D UN I V E R S A L CL A M P S 25 YE A R FU L L - S Y S T E M WA R R A N T Y F O R Q U E S T I O N S O R C U S T O M E R S E R V I C E V I S I T U N I R A C . C O M O R C A L L ( 5 0 5 ) 2 4 8 - 2 7 0 2 1402 E 18th St - 2017678710/03/22 LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DRAWING 4/28/2020 FLASHLOC COMP KIT REVISION DATE: DRAWING TYPE: DESCRIPTION: FL - A 0 1 PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART TABLE P/N DESCRIPTION 004085M FLASHLOC COMP KIT MILL, 20 PACK 004085D FLASHLOC COMP KIT DARK, 20 PACK 67 8" 31 2 " 33 4" 21 4 " 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHER SS SERRATED T-BOLT FLASHLOC BASE MILL OR DARK SS SERRATED FLANGE NUT 1402 E 18th St - Rev #2017926704/18/23 UN I R A C C U S T O M E R S E R V I C E M E A N S T H E H I G H E S T L E V E L O F P R O D U C T S U P P O R T EN G I N E E R I N G EX C E L L E N C E UN M A T C H E D EX P E R I E N C E PE R M I T DO C U M E N T A T I O N DE S I G N TO O L S CE R T I F I E D QU A L I T Y BA N K A B L E WA R R A N T Y BE T T E R D E S I G N S TR U S T T H E I N D U S T R Y ’ S B E S T D E S I G N T O O L St a r t t h e d e s i g n p r o c e s s f o r e v e r y p r o j e c t i n o u r U - B u i l d e r o n - l i n e d e s i g n t o o l . I t ’ s a g r e a t w a y t o s a v e t i m e a n d m o n e y . BE T T E R S Y S T E M S ON E S Y S T E M - M A N Y A P P L I C A T I O N S Q u i c k l y s e t m o d u l e s f l u s h t o t h e r o o f o n s t e e p p i t c h e d r o o f s . O r i e n t a l a r g e v a r i e t y of m o d u l e s i n P o r t r a i t o r L a n d s c a p e . T i l t t h e s y s t e m u p o n f l a t o r l o w s l o w r o o f s . Co m p o n e n t s a v a i l a b l e i n m i l l , c l e a r , a n d d a r k f i n i s h e s t o o p t i m i z e y o u r d e s i g n f i n a n c i a l s an d a e s t h e t i c s . BE T T E R R E S U L T S MA X I M I Z E P R O F I T A B I L I T Y O N E V E R Y J O B Tr u s t U n i r a c t o h e l p y o u m i n i m i z e b o t h s y s t e m a n d l a b o r c o s t s f r o m t h e t i m e t h e j o b i s q u o t e d t o t h e t i m e y o u r t e a m s g e t o f f t h e r o o f . F a s t e r i n s t a l l s . L e s s W a s t e . M o r e P r o f i t s . BE T T E R S U P P O R T WO R K W I T H T H E I N D U S T R I E S M O S T E X P E R I E N C E D T E A M Pr o f e s s i o n a l s u p p o r t f o r p r o f e s s i o n a l i n s t a l l e r s a n d d e s i g n e r s . Y o u h a v e a c c e s s t o ou r t e c h n i c a l s u p p o r t a n d t r a i n i n g g r o u p s . W h a t e v e r y o u r s u p p o r t n e e d s , w e ’ v e g o t yo u c o v e r e d . V i s i t U n i r a c . c o m / s o l a r m o u n t f o r m o r e i n f o r m a t i o n . UN I V E R S A L S E L F ST A N D I N G M I D C L A M P S U- B U I L D E R O N L I N E D E S I G N TO O L S A V E S T I M E & M O N E Y Vi s i t d e s i g n . u n i r a c . c o m BA N K A B L E W A R R A N T Y Do n ’ t l e a v e y o u r p r o j e c t t o c h a n c e , U n i r a c h a s t h e fin a n c i a l s t r e n g t h t o b a c k o u r p r o d u c t s a n d r e d u c e y o u r r i s k . Ha v e p e a c e o f m i n d k n o w i n g y o u a r e p r o v i d i n g p r o d u c t s o f ex c e p t i o n a l q u a l i t y . S O L A R M O U N T i s c o v e r e d b y a 2 5 y e a r li m i t e d p r o d u c t w a r r a n t y a n d a 5 y e a r l i m i t e d fi n i s h w a r r a n t y . TE C H N I C A L S U P P O R T Un i r a c ’ s t e c h n i c a l s u p p o r t t e a m i s d e d i c a t e d t o a n s w e r i n g q u e s t i o n s & a d d r e s s i n g i s s u e s i n r e a l t i m e . A n o n l i n e li b r a r y o f d o c u m e n t s i n c l u d i n g e n g i n e e r i n g r e p o r t s , st a m p e d l e t t e r s a n d t e c h n i c a l d a t a s h e e t s g r e a t l y si m p l i fi e s y o u r p e r m i t t i n g a n d p r o j e c t p l a n n i n g p r o c e s s . CE R T I F I E D Q U A L I T Y P R O V I D E R Un i r a c i s t h e o n l y P V m o u n t i n g v e n d o r w i t h I S O ce r t i fi c a t i o n s f o r 9 0 0 1 : 2 0 0 8 , 1 4 0 0 1 : 2 0 0 4 a n d O H S A S 18 0 0 1 : 2 0 0 7 , w h i c h m e a n s w e d e l i v e r t h e h i g h e s t s t a n d a r d s fo r fi t , f o r m , a n d f u n c t i o n . T h e s e c e r t i fi c a t i o n s d e m o n s t r a t e ou r e x c e l l e n c e a n d c o m m i t m e n t t o fi r s t c l a s s b u s i n e s s p r a c t i c e s . UL 2 7 0 3 BO N D I N G & G R O U N D I N G ME C H A N I C A L L O A D I N G SY S T E M F I R E C L A S S I F I C A T I O N LISTED S O L A R MO U N T CO N C E A L E D U N I V E R S A L EN D C L A M P S EN D C A P S I N C L U D E D WI T H E V E R Y E N D C L A M P EN H A N C E Y O U R R E P U T A T I O N W I T H Q U A L I T Y R A C K I N G S O L U T I O N S B A C K E D B Y E N G I N E E R I N G E X C E L L E N C E A N D A S U P E R I O R S U P P L Y C H A I N F O R Q U E S T I O N S O R C U S T O M E R S E R V I C E V I S I T U N I R A C . C O M O R C A L L ( 5 0 5 ) 2 4 8 - 2 7 0 2 PU B 2 0 1 8 A U G 3 1 – P R I N T E D U P D A T E 1402 E 18th St - 2017678710/03/22 SOLARMOUNT is the professionals’ choice for residential PV mounting applications. Every aspect of the system is designed for an easier, faster installation experience. SOLARMOUNT is a complete solution with revolutionary universal clamps, FLASHKIT PRO, full system UL 2703 certification and 25-year warranty. Not only is SOLARMOUNT easy to install, but best-in-class aesthetics make it the most attractive on any block! NOW FEATURING FLASHKIT PRO The Complete Roof Attachment Solution NOW WITH UNIVERSAL MIDCLAMPS Accommodates 30mm-51mm module frames One tool, one-person installs are here! REVOLUTIONARY NEW ENDCLAMPS Concealed design and included End Caps THE PROFESSIONALS’ CHOICE FOR RESIDENTIAL RACKING BEST INSTALLATION EXPERIENCE • CURB APPEAL • COMPLETE SOLUTION • UNIRAC SUPPORT SOLARMOUNT OPTIONAL FRONT TRIM New & Improved: THE PROFESSIONALS’ CHOICE With Superior Aesthetics CONCEALED UNIVERSAL CLAMPS 25 YEAR FULL-SYSTEM WARRANTY FOR QUESTIONS OR CUSTOMER SERVICE VISI T UNIRAC.COM OR CALL (505) 248-2702 1402 E 18th St - Rev #2017926704/18/23 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 MM INV INV SCALE: 1/16" = 1' SITE PLAN N (E)200A MAIN SERVICE PANEL (N)SOLAREDGE 5000H-US Non-RGM INVERTER ROOF ACCESS POINT PER CRC 2019 (R324.7.1) ARRAY 3 - (N)6 Canadian MODULES TILT: 18° AZIMUTH: 1° EXISTING PV SYSTEM (E) 18 SOLAR CITY 265 PV MODULES 1) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. 2) ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING. 3) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION. 4) THE SOLAR INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING OR MECHANICAL VENTS. 5) A LADDER WILL BE IN PLACE FOR INSPECTIONS IN COMPLIANCE WITH CAL OSHA REGULATIONS. 6) MODULE MOUNTING STRUCTURE WILL BE TIED DIRECTLY INTO STRUCTURAL ELEMENTS OF SINGLE FAMILY DWELLING ROOF TRUSSES / RAFTERS OR BEAMS ACCORDING TO MOUNTING STRUCTURE DIRECTIONS. 7) ROOF COVERING PENETRATIONS SHALL BE DESIGNED, INSTALLED AND MAINTAINED IN ACCORDANCE WITH BUILDING CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERINGS SHALL SERVE TO PROTECT THE BUILDING STRUCTURE. 8) CONDUIT, WIRING SYSTEMS AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP, OR VALLEY AS DIRECTLY AS POSSIBLE TO POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES. SITE PLAN ARRAY 2 - (N)7 Canadian MODULES TILT: 18° AZIMUTH: 271° ARRAY 1 - (N)2 Canadian MODULES TILT: 18° AZIMUTH: 271° P2 (E)DRIVEWAY (E)PROPERTY LINE Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 3/1/2023 3/1/2023 DATE: TIME: 12:06 PM 12:06 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. CONSTRUCTION NOTES FIRE CODE PATHWAY COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PRODUCTION METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC LOAD CENTER INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4" EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX LEGEND CALLOUTS PROPERTY LINE INSTALLER NOTES (E)ABB PVI-3.6- OUTD-S-US-Z-A 2 1402 E 18th St - Rev #2017926704/18/23 UNIRAC CUSTOMER SERVICE MEANS THE HIGHEST LEVEL OF PRODUCT SUPPORT ENGINEERING EXCELLENCE UNMATCHED EXPERIENCE PERMIT DOCUMENTATION DESIGN TOOLS CERTIFIED QUALITY BANKABLE WARRANTY BETTER DESIGNS TRUST THE INDUSTRY’S BEST DESIGN TOOL Start the design process for every project in our U-Builder on-line design tool. It’s a great way to save time and money. BETTER SYSTEMS ONE SYSTEM - MANY APPLICATIONS Quickly set modules flush to the roof on steep pitched roofs. Orient a large variety of modules in Portrait or Landscape. Tilt the system up on flat or low slow roofs. Components available in mill, clear, and dark finishes to optimize your design financials and aesthetics. BETTER RESULTS MAXIMIZE PROFITABILITY ON EVERY JOB Trust Unirac to help you minimize both system and labor costs from the time the job is quoted to the time your teams get off the roof. Faster installs. Less Waste. More Profits. BETTER SUPPORT WORK WITH THE INDUSTRIES MOST EXPERIENCED TEAM Professional support for professional installers and designers. You have access to our technical support and training groups. Whatever your support needs, we’ve got you covered. Visit Unirac.com/solarmount for more information. UNIVERSAL SELF STANDING MIDCLAMPS U-BUILDER ONLINE DESIGN TOOL SAVES TIME & MONEY Visit design.unirac.com BANKABLE WARRANTY Don’t leave your project to chance, Unirac has the financial strength to back our products and reduce your risk. Have peace of mind knowing you are providing products of exceptional quality. SOLARMOUNT is covered by a 25 year limited product warranty and a 5 year limited finish warranty. TECHNICAL SUPPORT Unirac’s technical support team is dedicated to answering questions & addressing issues in real time. An online library of documents including engineering reports, stamped letters and technical data sheets greatly simplifies your permitting and project planning process. CERTIFIED QUALITY PROVIDER Unirac is the only PV mounting vendor with ISO certifications for 9001:2008, 14001:2004 and OHSAS 18001:2007, which means we deliver the highest standards for fit, form, and function. These certifications demonstrate our excellence and commitment to first class business practices. UL2703BONDING & GROUNDING MECHANICAL LOADING SYSTEM FIRE CLASSIFICATIONL I S T E D SOLARMOUNT CONCEALED UNIVERSAL ENDCLAMPS END CAPS INCLUDED WITH EVERY ENDCLAMP ENHANCE YOUR REPUTATION WITH QUALITY RACKING SOLUTIONS BACKED BY ENGINEERING EXCELLENCE AND A SUPERIOR SUPPLY CHAIN FOR Q UE S TI ON S OR C US TOME R S E R VI C E VI S I T UN I R A C . C OM OR C A LL (5 0 5 ) 2 48 -2 7 0 2PUB2018AUG31 – PRINTED UPDATE 1402 E 18th St - Rev #2017926704/18/23 Digitally sealed by RJM on Date: Job #: Jurupa Valley, CA 92509 Email: SE@mcpe.group 7/8/22 7/8/22 22-8693 Mobile: (909) 566-0066 Structural Analysis Report For Photovoltaic System Addition to Existing Structure At The Angel Residence 1402 E 18th St. Santa Ana, CA 92705 Designed in Accordance with CBC 2019, ASCE 7-16, NDS 2018 E.O.R.: Ryan McPherson, P.E. 9240 Limonite Ave 7/8/2022 11:14 AM 1 of 7 ©McPherson Engineering 1402 E 18th St - 2017678710/03/22 McPherson Engineering By: M.M. Date: 7/8/22 Project Info 3 Gravity Loads 4 Lateral Loads 5 Wind Uplift Design 6 Summary 7 Table Of Contents 7/8/2022 11:14 AM 2 of 7 ©McPherson Engineering 1402 E 18th St - 2017678710/03/22 McPherson Engineering By: M.M. Date: 7/8/22 Location: 1402 E 18th St. Santa Ana, CA 92705 Existing Structure Info: Number of Stories = 1 Aroof = 2600 sq. ft. Roof Square Footage A3rd_flr = 0 sq. ft. Third Floor Square Footage (if applicable) A2nd_flr = 0 sq. ft.Second Floor Square Footage (if applicable) Site Properties: Lattitude = Longitude = Ss = 1.307 S1 = 0.466 Exposure Category = C Ult. Wind Speed = 110 m.p.h. P.V. Array Info: Model = Q.PEAK DUO BLK ML-G9+ 370 Height of Panel = 72.40 in. Width of Panel = 40.60 in. Area of Panel = 20.4 ft.2 Number of New Panels = 15 Number of Exis. Panels = 18 Total Area of Array = 673.6 ft.2 Spacing of Anchors = 4.0 ft. max. on center rows of racks per panel = 2 Panel Tilt = 7-27 deg Project Info 33.760930 -117.848291 7/8/2022 11:14 AM 3 of 7 ©McPherson Engineering 1402 E 18th St - 2017678710/03/22 McPherson Engineering By: M.M. Date: 7/8/22 Existing Loads: Roof Design Loads: Roofing = 4.0 p.s.f.Composition roofing Sheathing = 1.5 p.s.f.1/2" Plywood Framing = 1.5 p.s.f.2x Rafter/Truss Framing Misc = 1.0 p.s.f. DLr1 = 8.0 p.s.f.Roofing Dead Load (applied to top of rafters/trusses only) Ceiling = 2.0 p.s.f. Drywall and 2x framing DLr2 = 10.0 p.s.f. Total Existing Roof Dead Load LLr = 20.0 p.s.f. Roof Live Load (Per C.B.C, Table 1607.1) SL = 0.0 p.s.f.Snow Load Floor Design Loads: (if applicable) Flooring = 10.0 p.s.f.Weight of floor finish Sheathing = 2.2 p.s.f.3/4" plywood Framing = 2.0 p.s.f.2x framing or manufactured floor truss Interior Partitions = 15.0 p.s.f.2x framed walls with drywall finish each side Ceiling = 5.0 p.s.f.Drywall ceiling finish below Misc. = 0.8 p.s.f. DLf = 35.0 p.s.f.Total Existing Floor Dead Load Proposed Loads: Panels = 2.6 p.s.f. weight of panels including rack system DLr1_proposed = 10.6 p.s.f. Proposed Roof Dead Load (applied to top only) DLr2_proposed = 12.6 p.s.f.Total Proposed Roof Dead Load LLr_proposed = 0.0 p.s.f. Check Proposed Gravity Loads: Total Existing Roof Load Wex = (DLr1 + LLr) (Aroof) = 72.8 kips Total Proposed Roof Load Wprop = (DLr1 + LLr) (Aroof - Aarray) + (DLr1_proposed + LLr_proposed) (Aarray) = 61.1 kips Proposed Load Demand Wprop - Wex = -16.09% Wex TOTAL DECREASE IN GRAVITY LOADS, PANELS OK! Roof Live Load with panels no more than 24in above roof surface (panels cannot support live loads, including the weight of stacked materials or workers) Gravity Loads 7/8/2022 11:14 AM 4 of 7 ©McPherson Engineering 1402 E 18th St - 2017678710/03/22 McPherson Engineering By: M.M. Date: 7/8/22 Seismic Design Parameters Risk Category = 2 Per Table 1-5-1 R = 6.5 Response Modification Factor (Table 12-2.1) Site Class = D Per 11.4.2 Ie = 1 Seismic Importance Factor (Table 1.5-2) Ss = 1.31 Short Period P.G.A. S1 = 0.47 1-Sec Period P.G.A. S.D.C. = D Seismic Design Category Per 11.6 Fa = 1.20 Site Coefficient per Table 11.4-1 ASCE 7-16 Supplement #1 Tables used for Fa and Fv Fv = 1.70 Site Coefficient per Table 11.4-2 (note: section 11.4.8 Exception #2 calc used) SMS = SDS Fa = 1.57 Short Period M.C.E. Per Eq. 11.4-1 SM1 = SD1 Fv = 0.79 1-Sec Period M.C.E. Per Eq. 11.4-2 SDS = 2/3 (SMS) = 1.05 Short Period Design Parameter Per Eq 11.4-3 SD1 = 2/3 (SM1) = 0.53 1-Sec Period Design Parameter Per Eq 11.4-4 Approximate Fundamental Period (Per 12.8.2.1) per Eq. 12.8-7 hn = 15 ft Ct = 0.02 (per table 12.8-2) x = 0.75 (per table 12.8-2) T = 0.15 sec Approximate Fundamental Period TL = 8 sec Long-Period Transition Period per Figure 22-12 Seismic Response Coefficient (Per 12.8.1.1) CS = (SDS Ie)/R = 0.16 Seismic Response Coefficient Per Eq. 12.8-2 Cs1 = 1.5*(SD1 Ie)/R T = 0.80 Max. Seismic Response Coefficient Per Eq. 12.8-3 if T ≤ TL Cs2 = 0.01 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs2 = 0.044 SDS Ie = 0.05 Min. Seismic Response Coefficient Per Eq. 12.8-5 Cs3 = 0.5 S1 Ie/R = 0.04 Min. Seismic Response Coefficient Per Eq. 12.8-6 if S 1 ≥ 0.6g CS = 0.16 Design Seismic Coefficient Check Additional Base Shear Wexisting = 26.0 kips Weight of Existing Structure Wpanels = 1.8 kips Weight of Proposed Panels Vexisting = Cs Wexisting = 4.2 kips Roof Level Shear of Existing Structure Vpanels = Cs Wpanels = 0.3 kips Additional Roof Level Shear of Proposed Panels Vpanels Vexisting Lateral Loads T = Ct (hn) x = 6.75% < 10%PER C.E.B.C. 502.5 EXCEPTION, STRUCTURE DOES NOT REQUIRE SEISMIC RETROFIT, PANELS OK! 7/8/2022 11:14 AM 5 of 7 ©McPherson Engineering 1402 E 18th St - 2017678710/03/22 McPherson Engineering By: M.M. Date: 7/8/22 Rooftop Solar Panels Wind Pressures (Section 29.4, ASCE 7-16) Vult = 110 mph Kzt = 1.00 (sec 26.8.2) h = 15 ft Exposure Category = C Kz = 0.85 (sec 26.10.1) Roof Zone = 2 Kd = 0.85 (sec 26.6) Roof θ = 7-27 deg Ke = 1.00 (sec 26.9) qh = 0.00256 Kz Kzt Kd Ke V 2 qh = 22.38 (eq. 26.10-1) GPp = -2 uplift γE = 1.5 (sec 29.4.4) γa = 0.77 (fig 29.4-8) γE = 1.5 FIG 29.4-7)γc = 0.96 (fig 29.4-7) hpt = 0 γa = 0.77 (fig 29.4-8)γ p = 0.9 (fig 29.4-7)ω = 0.00 deg (panel tilt) GPp = -2 uplift GCrm = 1.4 uplift p = qh (GPp) γ E γa (eq 29.4-7) p = qh (GCrn) γ E γC γp (eq 29.4-6) p = -51.5 p.s.f.p = 40.7 p.s.f. Check Anchorage to Existing Structure 0.6DL - 0.6W controlling load combination (eq. 16-15 for ASD) DL = 2.6 p.s.f.dead load of panel (inlcuding rack system) W = 51.5 p.s.f.wind load normal to face of panel Arealag = 12.1 sq. ft.area tributary to each anchor SPanc = 4.0 ft.spacing of anchors Puplift = Arealag (0.6DL - 0.6W) = 354.1 lbs total uplift on anchor Material = DFL lumber anchor material Dialag = 5/16 in. diameter of screw Penlag = 2.5 in. min. penetration to existing framing Wlag = 266 lb/in. withdrawal load per in. of penetration per NDS Table 11.2A CD = 1.6 load duration factor for wind per NDS Table 2.3.2 Ct = 0.8 temperature factor per NDS Table 2.3.3 Noscrews = 1 number of screws in withdrawal Pallow = Penlag (Wlag CD Ct) * Noscrews = 851.2 lbs total allowable withrawal on anchor Puplift Pallow Anchorage = USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION 0.42 < 1.00 Anchor is OK! Wind Uplift Anchorage = Flush Mounted Panels - ASCE Section 29.4.4 (where applicable) Flat Roof Panels - ASCE Section 29.4.3 (where applicable) 7/8/2022 11:14 AM 6 of 7 ©McPherson Engineering 1402 E 18th St - 2017678710/03/22 McPherson Engineering By: M.M. Date: 7/8/22 Gravity Loads: DEMAND DECREASED BY 16.09% = OK! Lateral Loads: DEMAND INCREASED BY 6.75% < 10% = OK! Anchorage: DEMAND OF 354.1LB. < CAPACITY OF 851.2LB. = OK! USE (1) 5/16IN. DIA. LAG SCREW(S) AT 4FT. MAX. O.C. W/ 2.5IN. MIN. PENETRATION Summary: STRUCTURE IS ADEQUATE FOR THE PROPOSED PV ARRAY ANCHORS ON EAVES/OVERHANGS ARE OK! Summary 7/8/2022 11:14 AM 7 of 7 ©McPherson Engineering 1402 E 18th St - 2017678710/03/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 .\BRYSON Capture.PNG .\ b e t t e r - e a r t h - l o g o - f d 1 7 b d e 4 . p n g 48" FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE Comp Asphalt Shingles 2x6 RAFTERS @24"" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT AND FLASHING E 2x6 RAFTER TYPICAL SOL A R MOD U L E S Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Sunshine Bondal NE W P V S Y S T E M : 7 . 6 0 0 D C / 7 . 0 0 0 A C Ma r t i n A n g e l 14 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 7/4/2022 7/4/2022 DATE: TIME: 06:01 pm 06:01 pm PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. RACKING & FRAMING DETAILS P4 TYPICAL ROOF ATTACHMENT PLAN ATTACHMENT DETAIL FRONT VIEW TYP FRAMING DETAIL This item has been digitally signed and sealed on Jul 08, 2022 1402 E 18th St - 2017678710/03/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 MM INV INV Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 3/1/2023 3/1/2023 DATE: TIME: 12:06 PM 12:06 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. SCALE: 3/32" = 1' FIRE CODE PATHWAY N ARRAY 1: MODULE QTY: 2 TILT: 18° AZIMUTH: 271° MATERIAL: Comp Asphalt Shingles ARRAY 2: MODULE QTY: 7 TILT: 18° AZIMUTH: 271° MATERIAL: Comp Asphalt Shingles ARRAY 3: MODULE QTY: 6 TILT: 18° AZIMUTH: 1° MATERIAL: Comp Asphalt Shingles REQUIRED ROOF ACCESS POINT PER CRC 2019 SECTION R324. LADDER ACCESS SHALL BE AT STRONG POINT OF ROOF AND NOT OVER REQUIRED WINDOW OPENINGS. COMBO METER/MAIN UTILITY METER MAIN SERVICE PANEL PV METER UM MM MSP PV INVERTER SUB PANEL AC DISCONNECT AC COMBINER PANEL INV SUB ACL AC EV CHARGER BATTERY BACKUP BACKUP INTERFACE BACKUP GATEWAY EV BB BG BI MODULE STRINGING 3 4" EMT CONDUIT P401 OPTIMIZER JB JUNCTION BOX ROOF PLAN ROOF PLAN P3 ROOF DETAILS:LEGEND CALLOUTS: INSTALLER NOTES JB 1 6 ' -0 " 6' -0 " 12'-10" 6 '-0 " 6' -5 " 9' -3 " DOES NOT HAVE A RAPID SHUTDOWN DEVICE DOES NOT HAVE A RAPID SHUTDOWN DEVICE 1402 E 18th St - Rev #2017926704/18/23 (E) GROUNDING ELECTRODE GROUND ROD (N) AC COMBINER BOX 240/120 V 1Ø, 3W MAX MAIN BUS: 125A (N) 30 04 STRING 1: (15x) Canadian Canadian CS3N-395 PV MODULES WITH 15 S440 SE POWER OPTIMIZERS 01 JUNCTION BOX - NEMA 3R AS REQUIRED 2A INVERTER SOLAREDGE 5000H-US NON-RGM WITH DC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 3B+ - + - + - + - + - + - 1521 DC AC TO UTILITY GRID (Underground) MAX. BREAKER CALC.: 200A X 1.2 - POINT OF INTERCONNECTION LOAD SIDE 705.12(D)(2)(3)(B) MAIN (E) 175A 175A = 65A M BI-DIRECTIONAL UTILITY METER 1PH/240V (E) 200A/175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W JUNCTION BOX NEMA 4 EXISTING PV SYSTEM 18 EXISTING SOLAR PV MODULES WITH ABB PVI-3.6-OUTD-S-US-Z-A INVERTER 1 184 3 2 EXISTING AC DISCONNECT EXISTING INVERTER EXISTING PV SYSTEM TO EXISTING SOLAR PV BREAKER TO EXISTING SOLAR PV SYSTEM (E) 30A (N) 60A CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 1 #10 PV Wire, in open air FREE AIR N/A N/A #6 51 1 15 18.75 40 38.4 90 50 2 #10 THWN-2, in conduit 3/4" EMT 4 N/A #8 51 1 15 18.75 40 38.4 75 35 3 #10 THWN-2, in conduit 3/4" EMT 3 30 #8 32 1 21 26 40 38.4 75 35 4 #6 THWN-2, in conduit 3/4" EMT 3 60 #8 32 1 21 26 40 38.4 75 35 ASHRAE EXTREME LOW DESIGN TEMPERATURES ASHRAE 2% HIGH 32 32 POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS STRING 1 15A 15 380V 21A SYSTEM SUMMARY ARRAY STC POWER 5925W ARRAY PTC POWER 5535W MAX AC CURRENT 30A MAX AC POWER 5000W INVERTER 1 POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY SOLAREDGE S440 Optimizer MAX OUTPUT(A) MAX DC (V) INVERTER 1 SPECS SOLAREDGE 5000H-US_Non-RGM AC VOLTAGE (V) 240 GROUND 0.99 MAX OCPD (A) 30 RATED POWER (W) 5000 MAX OUTPUT (A) 21 MAX INPUT (A) 14 MAX INPUT (V) 480 EFFICIENCY (CEC) 0.99 MODULE SPECS Canadian Canadian CS3N-395MS PMAX (W) 395 PTC (W) 369 ISC (A) 11 IMP (A) 11 VOC (V) 44 VMP (V) 37 TEMP. COEFF. OF VOC -0.122 440 15 98.6 15 60 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 14 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 4/11/2023 4/11/2023 DATE: TIME: 07:31 AM 07:31 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELECTRICAL NOTES 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ALL WORK SHALL COMPLY WITH THE 2019 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. ELECTRICAL LINE DIAGRAM LINE DIAGRAM & DESIGN TABLES P5 DESIGN TABLES BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 1402 E 18th St - Rev #2017926704/18/23 OWNER Martin Angel PHONE: 1714-585-0226 EMAIL:martin.angel@ocpw.ocgov.com CONTRACTOR: BETTER EARTH ELECTRIC INC. PHONE: (888)373-9379 AUTHORITIES HAVING JURISDICTION BUILDING: Santa Ana (CA) UTILITY: Southern California Edison DESIGN SPECIFICATIONS OCCUPANCY: R-3/U CONSTRUCTION: V-B NAME: RESIDENTIAL SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH ROOF SURFACE: 2696 SQ.FT. PV SQ FOOTAGE: 320.13 SQ.FT. PV COVERAGE: 11.3 % WEIGHT OF EQUIPMENT: 715.35 NO. OF STORIES: 1 FIRE SPRINKLERS: NO LOT INFORMATION APN: 39622131 LOT AREA: 7482 LIVING AREA: 1964 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 4/11/2023 4/11/2023 DATE: TIME: 07:31 AM 07:31 AM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. PROPERTY INFORMATION Martin Angel 1402 E 18th St, Santa Ana, CA 92705 APN: 39622131 E SYSTEM SIZE: 5925 DC E SYSTEM SIZE: 5000 AC E CEC POWER OUTPUT: 5535 CEC MODULE INFORMATION MODULE QTY: 15 MODULE MFG: Canadian MODULE TYPE: Canadian CS3N-395 INVERTER INFORMATION INVERTER QTY:1 INVERTER MFG:SOLAREDGE INVERTER TYPE:5000H-US Non-RGM POWER OPTIMIZER INFORMATION OPTIMIZER QTY: 15 OPTIMIZER MFG: SOLAREDGE OPTIMIZER TYPE: S440 PROJECT DETAILS COVER SHEET P1 TABLE OF CONTENTS PAGE NUMBER: PAGE TITLE: P1 COVER SHEET P2 SITE PLAN P3 ROOF PLAN P4 RACKING & FRAMING P5 LINE DIAGRAM & DESIGN TABLES P6 PLACARDS & PLACARD MAP P7 OPTIMIZER MAP P8 JOB HAZARD ANALYSIS P9 ELEC. LOAD CALCS SS00 SPECIFICATION PAGES RAILING INFORMATION RAILING MFG:UNIRAC RAILING TYPE:Unirac SM Light MOUNTING INFORMATION MOUNT FLASHING QTY:30 MOUNT FLASHING MFG:UNIRAC MOUNT FLASHING TYPE:Unirac FlashLoc - Mill EXISTING SOLAR INFORMATION INVERTER QTY: 1 INVERTER MFG & TYPE : ABB PVI-3.6-OUTD-S-US-Z-A MODULE QTY: 18 MODULE MFG & TYPE: EXISTING PV MODULES BATTERY INFORMATION BATTERY QTY:N/A BATTERY MFG:N/A BATTERY TYPE:N/A 1. RESIDENTIAL ROOF MOUNTED PHOTOVOLTAIC SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURES SPECIFICATIONS AND THE 2019 CALIFORNIA RESIDENTIAL CODE, SECTIONS R314, R909 AND R918, 2019 CALIFORNIA ELECTRICAL CODE AND 2019 CALIFORNIA FIRE CODE. 2. CONTRACTORS SHALL BE PRESENT DURING ALL INSPECTIONS. 3. THE ROOF ACCESS POINT REQUIRING A LADDER SHALL NOT BE LOCATED OVER A WINDOW, DOOR OR LOCATED WHERE IT CONFLICTS WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS [CRC 324.7.1]. 4. A LADDER SHALL BE PROVIDED AND SECURED TO THE STRUCTURE AT THE APPROVED ROOF ACCESS POINT PER NOT "C" ABOVE WITH A CAL OSHA APPROVED DEVICE DURING ALL INSPECTIONS. 5. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATION'S INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 6. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS. [NEC 690.4(D)] 7. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 8. CONTACT THE SERVICING UTILITY BEFORE POWERING ON THE PHOTOVOLTAIC SYSTEM 9. ALL WORK SHALL COMPLY WITH APPLICABLE, LOCAL, MUNICIPAL CODES, AND TO MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. THE PV SOLAR SYSTEM WILL BE INTERCONNECTED AND OPERATED IN PARALLEL WITH THE UTILITY ELECTRICAL GRID PER THE REQUIREMENTS OF THE UTILITY AND APPLICABLE CODES. THE PV SOLAR SYSTEM IS DESIGNED IN COMPLIANCE WITH CEC 690.12 (RAPID SHUTDOWN). GENERAL NOTES · 2019 CALIFORNIA BUILDING CODE · 2019 CALIFORNIA RESIDENTIAL CODE · 2019 CALIFORNIA ELECTRICAL CODE · 2019 CALIFORNIA FIRE CODE · 2019 CALIFORNIA MECHANICAL CODE · 2019 CALIFORNIA GREEN CODE · 2019 CALIFORNIA PLUMBING CODE · 2019 CALIFORNIA ENERGY CODE · ANY OTHER LOCAL AND MUNICIPAL CODES CODE REFERENCES ADDITIONAL SCOPE OF WORK ADDING AC COMBINER BOX REVISIONS 04.11.23_ AHJ CORRECTION. 1 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 Revision to 101111217/101113502 BLDG# 101114580 ISS. 4/18/2023 Revision to 20176787/20178452 ELEC# 20179267 ISS 4/17/2023 1402 E 18th St - Rev #2017926704/18/23 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 FLUSH MOUNT SOLAR MODULES ATTACHED TO ROOF SURFACE Comp Asphalt Shingles 48" 2x6 RAFTERS @24"" O.C. SOLAR MODULES 7/16 X 3/4" NUT, FLANGE UNIRAC STANDARD RAIL 3/8" BOLT(E) COMPOSITION SHINGLE (E) ROOF SHEATHING TYP. PLACE SEALANT AROUND LAG BOLT AND UNDER STANDOFF BASE PREDRILLED 3/16" HOLE (1) 5/16" STAINLESS STEEL LAG BOLT W/ 2-1/2" MIN. EMBEDMENT (E) ROOF FRAMING TYP. 6" M A X UNIRAC COMP SHINGLE ATTACHMENT AND FLASHING E 2x6 RAFTER TYPICAL SOL A R MOD U L E S Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 3/1/2023 3/1/2023 DATE: TIME: 12:06 PM 12:06 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. RACKING & FRAMING DETAILS P4 TYPICAL ROOF ATTACHMENT PLAN ATTACHMENT DETAIL FRONT VIEW TYP FRAMING DETAIL 1402 E 18th St - Rev #2017926704/18/23 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 .\BRYSON Capture.PNG .\ b e t t e r - e a r t h - l o g o - f d 1 7 b d e 4 . p n g Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Sunshine Bondal NE W P V S Y S T E M : 7 . 6 0 0 D C / 7 . 0 0 0 A C Ma r t i n A n g e l 14 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 7/4/2022 7/4/2022 DATE: TIME: 06:01 pm 06:01 pm PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 42 34 43 35 44 36 45 37 46 38 47 39 48 40 49 41 50 OPTIMIZER MAP P7 SYSTEM SIZE 5550 W DC MODULE TYPE Hanwha Q CELLS Q.PEAK DUO BLK ML-G9+ 370 MODULE QTY 15 INVERTER TYPE SOLAREDGE 5000H-US Non-RGM INVERTER INVERTER QTY 1 POWER OPTIMIZER TYPE SOLAREDGE S440 POWER OPTIMIZER POWER OPTIMIZER QTY 15 SYSTEM DETAILS 52 53 54 56 57 58 60 61 62 64 65 66 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 51 55 59 63 67 1402 E 18th St - 2017678710/03/22 POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN CAUTION SERVICE BY QUALIFIED PERSONNEL ONLY N Nathan Draeger REV: DESCRIPTION: BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 3/1/2023 3/1/2023 DATE: TIME: 12:06 PM 12:06 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ROOFTOP PV ARRAY UTILITY METER AND MAIN SERVICE PANEL INVERTER YOU ARE HERE PLACARD & PLACARD MAP P6 LABELING PLAN LABEL DIRECTORY 6"X6" DISCONNECT DIRECTORY PLAQUE INSTALL AT MAIN SERVICE PANEL FORMAT 1. WHITE LETTERING ON A RED BACKGROUND 2. MINIMUM 3/8 INCHES LETTER HEIGHT 3. ALL LETTERS SHALL BE CAPITALIZED 4. ARIAL OR SIMILAR FONT (NON-BOLD) MATERIAL REFLECTIVE, WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (USE UL-969 AS STANDARD FOR WEATHER RATING). DURABLE ADHESIVE MATERIALS PROPERTY MAP PROPERTY MAP NOTES: INVERTER AC DISCONNECT EXISTING PV PANELS (DOES NOT HAVE A RAPID SHUTDOWN DEVICE) NEW PV PANELS NEW PV PANELS EXISTING PV PANELS (DOES NOT HAVE A RAPID SHUTDOWN DEVICE) BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 STICKER LOCATED INSIDE PANEL NEXT TO PV BREAKER 11 [CEC 690.14(C)(2)] PLACE ON AC DISCONNECT 8 9 [CEC 705.12(B)(2)(3)(C)] PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT LABELING NOTES: 1.1 LABELING REQUIREMENTS BASED ON THE NATIONAL ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 1910.145, ANSI Z535. 1.2 MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 1.3 LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 1.4 LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8” AND PERMANENTLY AFFIXED. PHOTOVOLTAIC SOLAR BREAKER PHOTOVOLTAIC AC DISCONNECT WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS 10 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY: SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED AND SHALL INDICATE THE LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN SWITCHES IF NOT AT THE SAME LOCATION. [CEC 690.56(C)(1)(A)] 2 3 [CEC 690.53] AT EACH DC DISCONNECT MEANS [CEC 690.5(C)] PLACE THIS LABEL ON ALL DISCONNECTING MEANS WHERE ENERGIZED IN AN OPEN POSITION 1 [CEC 690.31(G)3 & 4] PLACE ON JUNCTION BOXES AND CONDUIT EVERY 10' WARNING: PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE PHOTOVOLTAIC SYSTEM DC DISCONNECT MAX CIRCUIT CURRENT 15 AMPS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD WARNING MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-DC CONVERTER 4 [CEC 690.12(5)] PLACE ON INVERTER PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN 7 6 5 [CEC 690.54] PLACE LABEL AT "INTERACTIVE POINT OF INTERCONNECTION" (AT MAIN SERVICE PANEL AND SUBPANEL IF APPLICABLE) [CEC 690.64(B)(4)] PLACE LABEL ON ALL EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTORS SUPPLIED FROM MULTIPLE SOURCES CEC 705.12(B)(2)(3)(B) PLACE THIS LABEL AT P.O.C. TO SERVICE DISTRIBUTION EQUIPMENT (I.E. MAIN PANEL AND SUBPANEL IF APPLICABLE) SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY WARNING RATED AC OUTPUT CURRENT NOMINAL OPERATING AC VOLTAGE 240 V PHOTOVOLTAIC SYSTEM AC DISCONNECT DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONNECTION WARNING 21A 480 VDC 14 AMPS D STICKER LOCATED ON MAIN ELECTRICAL PANEL DO NOT UPSIZE MAIN BREAKER BREAKER WAS DOWNSIZED FOR PV SYSTEM WARNING SUB PANEL 5 6 JUNCTION BOX METER MAIN SERVICE PANEL 1 7 6 8 10 9 INVERTER INTEGRATED DC DISCONNECT 4 2 3 1 WHEN APPLICABLE AC DISCONNECT PRODUCTION METER AC DISCONNECT ROOFTOP ARRAY AC LOAD CENTER 7 3 5 8 3 5 8 3 5 5 11 WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE WHEN APPLICABLE 1402 E 18th St - Rev #2017926704/18/23 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 .\BRYSON Capture.PNG .\ b e t t e r - e a r t h - l o g o - f d 1 7 b d e 4 . p n g H HAZARD A ANCHOR POINT LEGEND L LADDER E ENTRY / EXIT WORK ANGLE ELECTRICAL ZONE WORK ZONE JOB HAZARD ANALYSIS Use the space below to draft a JHA. Be sure to include all indicators found in the Legend. (E) D R I V E W A Y (E) ENTRANCE NEAREST MEDICAL FACILITY: JOB HAZARD ANALYSIS P8 Nathan Draeger DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: Sunshine Bondal NE W P V S Y S T E M : 7 . 6 0 0 D C / 7 . 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , Sa n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 7/4/2022 7/4/2022 DATE: TIME: 06:01 pm 06:01 pm CREW LEAD: CREW: NAME: PHONE: ADDRESS: 1402 E 18th St - 2017678710/03/22 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 3/1/2023 3/1/2023 DATE: TIME: 12:06 PM 12:06 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 42 34 43 35 44 36 45 37 46 38 47 39 48 40 49 41 50 OPTIMIZER MAP P7 SYSTEM SIZE 5925 W DC MODULE TYPE Canadian Canadian CS3N-395 MODULE QTY 15 INVERTER TYPE SOLAREDGE 5000H-US Non-RGM INVERTER INVERTER QTY 1 POWER OPTIMIZER TYPE SOLAREDGE S440 POWER OPTIMIZER POWER OPTIMIZER QTY 15 SYSTEM DETAILS 52 53 54 56 57 58 60 61 62 64 65 66 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 51 55 59 63 67 1402 E 18th St - Rev #2017926704/18/23 BE T T E R E A R T H E L E C T R I C I N C . 18 1 5 W I L S H I R E A V E N U E , S T E . 9 0 8 / 9 0 9 SA N T A A N A , C A 9 2 7 0 5 PH O N E # : ( 8 8 8 ) 3 7 3 - 9 3 7 9 LI C # : C 1 0 - 1 0 2 4 4 6 0 H HAZARD A ANCHOR POINT LEGEND L LADDER E ENTRY / EXIT WORK ANGLE ELECTRICAL ZONE WORK ZONE JOB HAZARD ANALYSIS Use the space below to draft a JHA. Be sure to include all indicators found in the Legend. (E) DRIVEWAY (E) ENTRANCE NEAREST MEDICAL FACILITY: JOB HAZARD ANALYSIS P8 Nathan Draeger DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: Alexis Arellano NE W P V S Y S T E M : 5 5 5 0 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , Sa n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 3/1/2023 3/1/2023 DATE: TIME: 12:06 PM 12:06 PM CREW LEAD: CREW: NAME: PHONE: ADDRESS: 1402 E 18th St - Rev #2017926704/18/23 9/28/2022 City of Santa Ana Engineering building plan review Re: Plan Review Comments Project Address: 1402 E 18th St, Santa Ana, CA 92705 Dear Plan Reviewer, This letter is intended to address the request for the changes that occurred on our planset.  Updated module layout, module type & module quantity based on As-built  Reflected Existing system details  Updated roof plan on P3  Updated Placard on P6 If you have any additional questions or concerns, please do not hesitate to contact me directly. Sincerely, Nathan J. Draeger Design & Engineering Manager nathan.d@betterearth.solar 1402 E 18th St - Revision #2017845202/15/23 Low NMOT: 42 ± 3 °C Low temperature coefficient (Pmax): -0.36 % / °C * As there are different certification requirements in different markets, please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region in which the products are to be used. linear power output warranty* PRODUCT CERTIFICATES* ISO 9001:2015 / Quality management system ISO 14001:2015 / Standards for environmental management system OHSAS 18001:2007 / International standards for occupational health & safety MANAGEMENT SYSTEM CERTIFICATES CANADIAN SOLAR INC. is committed to providing high quality solar products, solar system solutions and services to customers around the world. No. 1 module supplier for quality and performance / price ratio in IHS Module Customer Insight Survey. As a leading PV project developer and manufacturer of solar modules with over 40 GW deployed around the world since 2001. (1000 V / 1500 V) KuMax CS3U-380|385|390|395|400MS HIGH EFFICIENCY MONO PERC MODULE High High PTC rating of up to: 93.24 % CANADIAN SOLAR INC. 545 Speedvale Avenue West, Guelph, Ontario N1K 1E6, Canada, www.canadiansolar.com, support@canadiansolar.com Lower hot spot temperature Low power loss in cell connection Minimizes micro-crack impacts MORE POWER Better shading tolerance MORE RELIABLE IEC 61215 / IEC 61730: VDE / CE / CQC / MCS / KS / INMETRO UL 1703 / IEC 61215 performance: CEC listed (US) / FSEC (US Florida) UL 1703: CSA / IEC 61701 ED2: VDE / IEC 62716: VDE / IEC 60068-2-68: SGS Take-e-way Heavy snow load up to 5400 Pa, wind load up to 3600 Pa* * For detailed information, please refer to the Installation Manual. 5BBMBB *According to the applicable Canadian Solar Limited Warranty Statement. enhanced product warranty on materials and workmanship* 1402 E 18th St - Rev #2017926704/18/23 (E) GROUNDING ELECTRODE GROUND ROD STRING 1: (15x) Canadian Solar CS3N-395MS [Blk] PV MODULES WITH 15 S440 SE POWER OPTIMIZERS 1 JUNCTION BOX - NEMA 3R AS REQUIRED 2 INVERTER SOLAREDGE 5000H-US NON-RGM WITH DC DISCONNECT PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN PER NEC 690.12 3+ - + - + - + - + - + - 1521 DC AC VISIBLE/LOCKABLE AC DISCONNECT 30A AC NON-FUSED 240V, NEMA 3R 4 TO UTILITY GRID (Underground) MAX. BREAKER CALC.: 200A X 1.2 - POINT OF INTERCONNECTION LOAD SIDE 705.12(B)(3)(2) MAIN (N) 175A 175A = 65A M BI-DIRECTIONAL UTILITY METER 1PH/240V (E) 200A/175A MAIN SERVICE PANEL 240/120v 1-PH, 3-W JUNCTION BOX NEMA 4 EXISTING PV SYSTEM 18 EXISTING SOLAR PV MODULES WITH ABB PVI-3.6-OUTD-S-US-Z-A INVERTER 1 184 3 2 EXISTING AC DISCONNECT EXISTING INVERTER EXISTING PV SYSTEM TO EXISTING SOLAR PV BREAKER (N) 60A E 125A SUB PANEL 120/240V NEMA 3R UL LISTED (E) 30A 5 EXISTING PV (N) 30A CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR. FACTOR CONDUIT FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP. DERATED AMP. TERM. TEMP. RATING AMP. @ TERMINAL 1 #10 PV Wire, in open air FREE AIR N/A N/A #6 51 1 15 18.75 40 38.4 90 50 2 #10 THWN-2, in conduit 3/4" EMT 4 N/A #8 51 1 15 18.75 40 38.4 75 35 3 #10 THWN-2, in conduit 3/4" EMT 3 30 #8 32 1 21 26 40 38.4 75 35 4 #10 THWN-2, in conduit 3/4" EMT 3 30 #8 32 1 21 26 40 38.4 75 35 5 #6 THWN-2, in conduit 3/4" EMT 3 60 #8 32 1 21 26 75 72 75 35 ASHRAE EXTREME LOW DESIGN TEMPERATURES ASHRAE 2% HIGH 32 32 POWERBOX MAX OUTPUT CURRENT OPTIMIZERS IN SERIES NOMINAL STRING VOLTAGE ARRAY OPERATING CURRENT STRING DETAILS INVERTER 1 STRING CALCULATIONS STRING 1 15A 15 380V 21A SYSTEM SUMMARY ARRAY STC POWER 5925W ARRAY PTC POWER 5535W MAX AC CURRENT 30A MAX AC POWER 5000W INVERTER 1 POWER OPTIMIZERS RATED INPUT (W) MAX INPUT ISC (A) WEIGHTED EFFICIENCY SOLAREDGE S440 Optimizer MAX OUTPUT(A) MAX DC (V) INVERTER 1 SPECS SOLAREDGE 5000H-US_Non-RGM AC VOLTAGE (V) 240 GROUND 0.99 MAX OCPD (A) 30 RATED POWER (W) 5000 MAX OUTPUT (A) 21 MAX INPUT (A) 14 MAX INPUT (V) 480 EFFICIENCY (CEC) 0.99 MODULE SPECS Canadian Solar CS3N-395MS [Blk] PMAX (W) 395 PTC (W) 369.1 ISC (A) 11.44 IMP (A) 10.68 VOC (V) 44.3 VMP (V) 37 TEMP. COEFF. OF VOC -0.122 440 15 98.6 15 60 Nathan Draeger REV: DESCRIPTION:BY: DATE: DRAWING TITLE: DESIGNER: DESIGN MGR: DWG PAGE: ENGINEER OF RECORD Paul Kelvin Macavinta NE W P V S Y S T E M : 5 9 2 5 D C / 5 0 0 0 A C Ma r t i n A n g e l 1 4 0 2 E 1 8 t h S t , S a n t a A n a , C A 9 2 7 0 5 AP N : 3 9 6 2 2 1 3 1 5/5/2023 5/5/2023 DATE: TIME: 05:02 PM 05:02 PM PROPRIETARY & CONFIDENTIAL BETTER EARTH INC. ALL RIGHTS RESERVED. DO NOT DISSEMINATE WITHOUT EXPRESS WRITTEN CONSENT. ELECTRICAL NOTES 1. PV SOURCE CIRCUIT(S) ARE TO BE SUNLIGHT-RESISTANT PV-WIRE AS PERMITTED BY CEC 690.31(B). 2. ALL DIRECT CURRENT CIRCUITS ARE TO BE INSTALLED IN METAL RACEWAY FROM THE POINT OF PENETRATION OF THE SURFACE OF THE BUILDING OR STRUCTURE TO THE MAIN SERVICE PANEL AS MANDATED BY CEC 690.31(E). 3. WEATHERPROOF J-BOX – NEMA 3R. 4. ALL WORK SHALL COMPLY WITH THE 2022 CALIFORNIA ELECTRICAL CODE (C.E.C.) AND ALL OTHER LOCAL CODES AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. ELECTRICAL LINE DIAGRAM LINE DIAGRAM & DESIGN TABLES P5 DESIGN TABLES The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. REVISION TO Elec# 20179267 Issued 04/17/23 Elec# 20179666 Issued 07/11/23 1402 E 18th St - Rev #2017966607/12/23 Date_____________ To Whom it May Concern, I ______________________________ , the owner of the property located at, Property Owner Name ADDRESS:_________________________________________ I Have hired, Better Earth Electric Inc, State Lic #1024460, to install a PV Solar System: __________________________________________________________________ __________________________________________________________________ __________________________________________________________________ Kind Regards , ________________________________ Signature ________________________________ Print Name 07/08/2022 Martin Angel 1402 E 18th St Solar panels with 15 panels, 5.55 KW 1402 E 18th St - 2017678710/03/22 PCC-13 Rev. 06-17-2019 White-Plan Check Yellow-Applicant REVISION /SUPPLEMENTAL PLAN CHECK REQUEST PCC-13 CBC 2019 Rev 4/2022 Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Project Address: _________________________________________ Suite #_______________________________ New Plan Check No.____________________________________________________________________________ Original Plan Check No.:__________________________________ Permit Issuance Date:____________________ Original Plan Checker: __________________________________________________________________________ Amount Paid: $__________________________________________ Misc. Receipt #: ________________________ Processed by: ___________________________________________ Date: ________________________________ Plan Checker Approval: ___________________________________ Date: ________________________________ Additional Hours:________________________________________ @ $247.72 = $ _________________________ Print Name:_____________________________________________ Signature: ____________________________ Representing: ________________________________________________________________________________ Telephone: ( ) ____________________________________ Fax: ( ) __________________________________ Contact Person: ________________________________________ Telephone: ( ) ________________________ E-mail (Strongly Recommended): _________________________________________________________________ PLANS PREPARED BY AN ARCHITECT OR ENGINEER MUST BE SIGNED BY THE PROFESSIONAL WHO PREPARES THEM. PLEASE WRITE A BRIEF DESCRIPTION OF THE REVISION/SUPPLEMENT AND IF POSSIBLE AREA OF WORK. ALL REVI- SIONS ARE TO BE CLOUDED AND PROPERLY IDENTIFIED: (i.e. Deltas, Sheet Numbers, etc.). Electrical, Plumbing and/or Mechanical plans – stamped job set shall accompany revised plans. ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ 1402 E 18th St 20176787 10/3/22 455.19 Mark Hellsund Better Earth 661 470-2108 Mark Hellsund 661 470-2108 Mark.H@betterearth.solar Revised plans to reflect system being tied in to msp vs. subpanel 1402 E 18th St - Revision #2017845202/15/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1402 E 18th St - 2017678710/03/22