Loading...
HomeMy WebLinkAbout10179685_1406 S. VILLAGE WAY - PlanPlanning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www. santa-ana.orq ELECTRICAL SIGN REQUIREMENTS Raf#yamVMBAMM*404*#IN/Ar#NmPgaahiNFS.Ve#11)&4'fwifula'#aan·Di*VIBSFARFRAAiWPA#haFmSi;.92*.2*3*:43 Code references are to the 2010 California Electrical Code (CEC)C-11: 3-21-2011 A. All signs require Planning Department approval. B. All electrical signs require electric plancheck and permit. 1. Manufacturer's instructions are required at the time of submittal. 2. Submit detailed installation instructions including diagrams to the Building Department for plan review at the time of submittal. Plans must ihclude appropriate items noted by this bulletin. 3. Cash or surety bond in the amount of $200.00 is required at time of issuance for each address. The cash or surety bond will be refunded after all required finals. C. A building permit is also required - except for open or highlight neon lighting. D. Installation Requirements: CONTACT FIELD INSPECTOR PRIOR TO SIGN INSTALLATION. (SEE SECTION G OF THIS BULLETIN) 1. Conductors and equipment shall comply with California Electric Code Article 600. 2. All metal parts of a sign shall be bonded in ttie manner specified in Article 250. Isolated metal parts are permitted to be bonded by using an external green insulated conductor. Equipment grounding & bonding conductors must be sized by 110.26 and protected from physical damage. Minimum size is 14 AWG. CEC 600.7 3. A listed disconnect switch in the power supply primary, shall be installed within sight of sign or have permanently installed means for locking in an 'OFF" position. This is also true for a transformer enclosure. CEC 600.6 4. A listed receptacle or an approved termination device shall be used for each neon electrode. To relieve stress at terminations, tubing shall be supported with listed tube supports in an approved manner within six inches.of electrode connection. CEC 600.41 & 600.42 5. Every electric sign of any type shall be listed by an approved testing laboratory and shall be installed in conformance with this listing. That includes "1 of x", "2 of x" labeling for each separate unit of a multi-unit sign. CEC 600.3 6. All "can" letters and transformers housings shall have section labels that are readily visible after installation. CEC 600.4 7. Transformers shall be located where accessible and be securely fastened in place. Page 1 of 2 When not inside the sign, they need a 3 foot high x 3 foot wide x 3 foot deep workspace. Transformers are permitted to be located in attics or canopies provided there is a passageway at least 3 feet high x 2 feet wide with a minimum 12 inch catwalk/walkway from the point of entry. Transformers must be securely fastened and independent of T- bar when above a suspended ceiling. No part of siqn may be fed with flexible cord when located above T-bar ceilings. CEC 600.21(E&F) & 400.8 8. Adequate illumination shall be provided for all working spaces about electrical equipment. This applies to attics and canopies when entry is required to service or inspect the equipment. At least one switch is required at entrance. CEC 110.34 & 600.21 9. Doorway to an attic or canopy space shall be minimum 3 feet by 2 feet wide. CEC 600.21(E) E. Open neon outline or highlight lighting. 1. To be treated as a sign by this department. However, Section D-5 & D-6 of this bulletin will not apply. 2. Neon tubing shall be located where not normally exposed to physical damage. Open neon tubing below 9 feet shall be protected from physical damage by an approved shielding method. CEC 600.30 and 110.34(E) F. Light-Emitting Diode (LED) Signs 1. Will be treated as a sign by this department. All sign rules in sections A, B, C, D, F, and G will apply as appropriate. 2. LED illumination for signage must be a listed or recognized component. Many LED manufacturers specify particular brands and models of transformers some do not. Manufacturer information to clarify this issue is required on LED sign plans. 3. Unlisted LEDs may not be used in an electrical sign or as permanently installed illumination. 110.3 4. Please have packaging or catalog cut-sheets on hand for inspector to review when LED modules do not bear listing symbols. G. Inspections 1. Contact an Electrical Inspector one (1) workday (minimum) in advance of installation to arrange a site meeting on dav of installation. 2. Call for inspection Monday through Friday, 8:00- 8:30 a.m. at (714) 647-5821. Approved prints and the job card must be on site for inspection. Page 2 of 2 LED Driver RmetdiNE*P[N®tilitg *20-60 Watts max. 11//10 elitligam 120 VAC IMImihi7%1EII!D One aZEISKEMI,[REALEE[5970*Im 2|j[1£[6 EE*inURES • Extruded aluminum enclosure • 240mm x 68mm x 44mm (LxWxH) • 120VAC input only (220Vac available) • Pigtail input and output cords • High efficiency at 85% meets Energy Star • Short circuit/Overload protection • Tight regulated constant voltage output • IP66 compliant • One year warranty .0 Operating temperature:-30 to +50 ° C (de-rate 2.5% per deg. from 50 to 70 °C) Storage temperature:-40 to +85 ° C Humidity (Non-Condensing):5% to 95% Cooling:Convection Vibration Frequency:5 to 50 Hz MTBF:>100,000 Hours at fullload and 25°C ambient conditions (MIL-217F) Picture shown above is not to scale SPECIFICATION PARAMETER Input Voltage (VAC) Input Frequency (Hz) Output Voltage (VDC) Output Current (max.) Output Power (W) Efficiency Short CiA¢uit Protection Overload Protection Thermal Protection Operational Temperature Storage Temperature Max. Temperature at Tc Safety Approval Dimension Note: "xx" = DC output voltage LP12060P-xx LP24060P-xx 100 - 120VAC 50/60 Hz 50/60 Hz , 8-12VDC 22 - 24VDC 5.0 A max.2.5 A max. 60W Max.60W Max. 85% typ. at 1 10VAC, full load Yes 130% of the rated power Shut down when internal temp. over 85 Deg. C -30 - 50 Deg. C (de-rate 2.5% per deg. from 50 to 70 °C) -40 - 85 Deg. C 90 Deg. C UL Recognized (UL879, Class 2) 240mm x 68mm x 44min (LxWxH) 0 ECH NDUSTRIES CORP.5625-A S. Arville, Las Vegas, NV 891181'el:702-364-9998 Fax: 702-364-1562 www.inaglechind.com Anz!420 1 Distributed by: Power Sources Unlimited, Inc., Wrentham, MA Tel: 508-384-1419 I E-mail: sales@psui.com I Website: www.psui.com Model No.LS0766 Sheet No. 01 t 9,1 h,- Features I Super thin design, Patent product, UL approval * Super bright tri-chip SMD 0 Long life-span and low light decay 0 Low power consumption, high energy efficiency I Environmental friendly,RoHS compliant I UL,CE,ISO certified 0 With adhesive tape on the back or screws for easy installation MAX 100PCS a ¤ --------------- 0 m 15.5mm Power - DC 12V - ID 0 ----- ' 42mm' 1 1 : • All dimension is in mm o Tolerance ist.0.25 unless otherwise noted 0 100 pcs/box 1.Please rip PE adhesive tape on the bock ot the product. then stick to the objects where you want. 2.Uselhe screws tolasten It again. 42mm ' -77_5mm ModeINo.LS0766 Sheet No. 02 LED MODULE SERIES (LS-0766) Specifications:Unit Item NO.LS0766 Voltage DC12 Power/PC 0.5 LED Qty/PC 2 PCS Max piece 100 PCS RED 620-630 Green 510-530Wavelength nm Blue 460-470 Yellow 580-592 Warm White 3200-3500 Color Temperature K Cool White 8000-12000 Beam Angle 120°0 Warm White 24-29 Lum/PC I m Cool White 30-36 Size (L)42 x (W) 15,5 x (H}5 mm IP Rating IP44 Operation Temperature -40-60 E Storage Temperature -40-60 E Confirmed by Customer: Date: C €1 C."Fliaus _EGS- Rel-(S Model No.LS0766 Sheet No. 03 CIE Chromaticity Diagram S20 /510 070 1 1580 0.60 490 580 590 0.40 · i 0 A•\ 610 eD 630 - 1 480 om \470 1 400 000 0.00 o.to 0/0 040 O-am X 0/0 1 t-. - Light Decay Testing:(Chart:TC=25t. Vot=DC 12V ) (Lurri) 100% o U -I El I O O 1 7 90% 80% 70% 60% 50% 40% 30% 20% 10% 0%(Hours) 0 168 336 504 672 840 1008 1176 1344 1512 1680 1848 2016 2184 b- Important Notes: 0 Connect red wire to the positive polarity and black wire to the negative polarity of power supply I Operate on 12 Volt DC Power Supply(constant voltage) 0 Wire length of power supply should be no more than 3 meters;if more than that,suggest increasing wire diameter 87 SIGN COMPONENTS MANUAL (SAM)June 19, 2013 SANTA CLARA, CA 95054 Class 2 LED Panel, GLB Series. 1. These products are only suitable for connection to the output of a Class 2 Power Supply rated 24VDC. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 requirements. 3. These products are rated per the Table on Page 2. When units are connected to a Class 2 circuit, their number is to be limited to draw a total wattage of no greater than the secondary current rating of each Class 2 power supply. 4. These products are suitable for use in dry and damp locations without additional enclosures. LVC CONNECTORS INC 6068 METROPOLITAIN E E339231 MONTREAL, QC Hl S 1A9 CANADA PVC Tube, Models LVC-3 and TK-24-XXX. 1. These products are only suitable for protecting listed Class 2 wiring that are supplied by power supplies that are marked as having a Class 2 output or LPS. 2. For outside wall use only. 3. Not suitable for inside walls. 4. These products may be secured in place in the end product by any means available. Class 2 Low Voltage Connectors, Model LVC2, LVC4, SNAP-KONEK 111, and STICK-KONEK. 1. These devices are not suitable for interrupting the flow of current by connecting or disconnecting. 2. These products are only suitable for connection to a Class 2 power source, Class 2 supply rated max. 15 Volts AC or max. 30 Volts DC or less. 3. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limits. 4. These products are suitable for use in dry, damp and wet locations. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. Modules can be installed to interconnect leads in the field or pre-installed. 7. These products may be secured in place in the end product by mechanical securement or double sided adhesive tape. 8. For Model LVC2 and LVC4, suitable for connecting stranded wires which are 18, 20 or 22 AWG with compatible wire guide inserts. 9. For Model SNAP-KONEK Ill, suitable for connecting single conductor per channel either AWM wires 18-24 AWG, or Power- Limited Circuit Cables type CL3P, CL3R, CL3, CL3X, CL2P, CL-2R, CL2, CL2X and PLTC. 10. The Model STICK-KONEK base and button are used to join LED strips, LED bars, or LED leads wires. AGTECH INDUSTRIES CORP E314969 5625-A S ARVILLE ST LAS VEGAS, NV 89118 Class 2 LED M od u l e, C a t. N o. L P 1 2 0 6 0 P- 08, L P 1 2 0 60 P-09, L P 1 2 060 P- 1 0, L P 1 20 60 P - 1 1, LP 1 2 0 6 0 P - 1 2, L P 2 4060 P- 22, LP24060P-23,LP24060P-24. 1. These power supplies have a maximum of one Class 2 output. The output of these power supplies has been evaluated to Class 2 output requirements for dc circuits. 2. These products with Class 2 outputs are suitable for use in dry, damp and wet locations. 3. In the end product, power supply spacing to other heat producing components shall be minimum 4 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 4. When used in wet locations, each unit shall be provided with Listed (QCRV) 1/2 inch, liquid tight conduit fittings on both primary and secondary circuits. MATRIX FRAME FLEVOWEG 27 E351057 2318 BZ LEIDEN, THE NETHERLANDS Class 2 LED Module, "Lightbox CREE XP LEDstrip". 1. These products are suitable for use in Dry and Damp Locations Only and may only be supplied with a Class 2 power source with Current limit rated max. 2.5 Amps or less. 2. These products are only suitable for connection to a Class 2 or LPS power source, rated 24 Volt DC or less. 3. These products shall be mounted in equipment, which provide a suitable overall enclosure. 4. A maximum of 4 Led strips are allowed to be mounted in a row, as detailed in the mounting instructions. 5. These products may only be installed in a metal based enclosure (frame) that is able to transfer the heat that comes from the LEDs over the metal-core Printing Wiring Board into the ambient. MATRIX FRAME FLEVOWEG 27 E358648 2318 BZ LEIDEN, THE NETHERLANDS Class 2 LED driver box, Model A120606. 1. The power supply has been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 output. 2. The Class 2 output of the power supply is suitable for use in dry and damp locations only. 3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 4. These products shall be enclosed in the end product. 5. These products are suitable for factory wiring only. 13 SIGN COMPONENTS MANUAL (SAM)June 19, 2013 5. Grounding of frame to supply ground is required. Suitability of bonding for grounding connection is to be determined in final application. 6. Suitability of LED panel mounting shall be determined in final application. 7. Suitability of LED power source shall be determined in the final application. Polymeric adhesive systems, Cat Nos. DP-810 and DP-810 Black designated "Scotch-Weld" 1. The use of these adhesive systems shall be employed in applications wherein the limitations specified in Table A are not exceeded. 2. These systems may be used for securement to any combination of surfaces Listed in Table A, provided the use of temperature is no higher than the lowest temperature rating of any element of the combination 3. The materials have been evaluated for adhesive compatibility and stability only. No electrical or flammability tests have been performed on the adhesive by itself. The Engineer must consider the need to investigate the part of other than the properties investigated, in accordance with the applicable UL-end product Standard or requirements outlined in the Standard for Polymeric Materials - Use in Electrical Equipment Evaluations, UL 746C. 4. The suitability for use when exposed to oil, chemicals, refrigerant, soaps, X-rays, ultraviolet light and the like, has not been determined. 5. These systems are suitable for application to smooth flat surfaces. The need for adhesive bond strength test when applied to another surface or configuration shall be determined in the particular end use application. 6. These systems are also suitable where exposed indoors or outdoors to high humidity or occasional exposure to water. The minimum temperature rating is -35°C (-31°F). 7. The adhesive shall be applied in accordance with the manufacturer''s instruction. All surfaces shall be clean and dry. The manufacturer's instructions regarding cure time shall be followed. 8. The adhesive bond strength specified in Table A includes a safety factor of four. 9. When considering the use of any adhesive covered by this Report, the strength of the adhesive joint used to position parts shall be capable of withstanding the maximum force that might be applied to the joint in the end application. This is called the bond strength and includes static load as well as wind loading(dynamic load). The minimum square inches of adhesive to use is determined by dividing the maximum load in pounds by the adhesive bond strength specified in Table A. TABLE A Cat. Nos.DP-810, DP-810 Black Thickness: 0.076 mm (0.003 in) Substrate Combination Max. Operating Temp.Adhesive Bond °C (°F)Strength(PSI) Stainless Steel to Stainless Steel 60 1000 Aluminum to Aluminum 60 980 Polycarbonate to Polycarbonate 60 180 Magnesium to Magnesium 60 870 Acrylonitrile Butadiene Styrene to Acrylonitrile 60 310 Butadiene Styrene Cat. Nos.DP-810, DP-810 Black Thickness: 0.254 mm (0.010 in) Substrate Combination Max. Operating Temp.Adhesive Bond Strength °C (°F)(PSI) Stainless Steel to Stainless Steel 60 940 Aluminum to Aluminum 60 900 Polycarbonate to Polycarbonate 60 190 Magnesium to Magnesium 60 690 Acrylonitrile Butadiene Styrene to Acrylonitrile 60 430 Butadiene Styrene AA LED SUPPLY CORP E325964 9441 VALLEY BLVD. ROSEMEAD, CA 91770 Class 2 LED modules, Models LS0723x, LS0766x, LS0769x, LS0776x, where that x may be R, G, B or Y indicating LED Color. 1. These products are only suitable for connection to the output of a UL Listed or FUC Class 2 Power Supply rated 12VDC. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 requirements. 3. These products are rated per the Table below. When units are connected to a Class 2 circuit, their number is to be limited to draw a total wattage of no greater than the secondary current rating of each Class 2 power supply. Part No.Operating Current per Watts per module Voltage module LS0723x 12Vdc 40mA 0.48W LS0766x 12Vdc 30mA 0.36W LS1769x 12Vdc 75mA 0.90W LS0776x 12Vdc 60mA 0.72W June 19, 2013 SIGN COMPONENTS MANUAL (SAM) 14 4. These products are suitable for use in dry, damp and wet locations without additional enclosures. Class 2 LED Modules, Model AA-0766EC-XX, where XX can be any alpha characters or blank to represent different light color 1. These products are only suitable for connection to a Class 2 power source rated 12 Volt DC or less. 2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage and energy limited circuit and which is rated greater than 12 V DC. 3. These Class 2 LED modules are each rated as noted in the electrical ratings tables. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 12 Volts DC or less. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. ABC SIGN PRODUCTS E80767 2028 SE FRONTAGE RD FT COLLINS, CO 80525 Lampholder adapter, Type LH. 1. This device is suitable for use in indoor or outdoor extruded aluminum awning frames. 2. This adapter is intended for use only with Listed, single or double contact, recessed lampholders (Cat. No. 530, Kulka) which snap-fit into, and are securely held by, the adapter. The lampholder shall be held securely with or without a lamp in place. 3. This adapter is intended to complete the enclosure housing of insulated live parts only. 4. This device shall be installed in an aluminum extrusion in accordance with the "Installation Instructions" supplied by the manufacturer in the smallest shipping container. Sign Face Tensioning System, Model ABC. 1. The suitability of these tensioning systems in combination with any R/C (UYMR2) Flexible Sign Face Material to prevent entrance of water in outdoor sign applications shall be determined in the end product. 2. This product has not be evaluated for use as an electrical enclosure. 3. Tensioning clips shall be spaced as described in the Installation Instructions. 4. When employed in a sign with any frame dimension greater than 6 feet the sign shall be provided with a means to prevent billowing. 5. The mounted assembly of sign face material in these tensioning systems shall comply with the electrical and thermal spacing requirements of UL 48. 6. These clips have been determined to be suitable with any R/C Flexible Sign Face Material of min. 0.020 inches (0.51 mm) thick, suitability for use with a material of lesser thickness shall be determined in the end product. ABLE APPLIED TECHNOLOGIES LTD E329973 BOUNDARY HOUSE BUSINESS CENTER BOSTON MANOR RD LONDON, W7 2QE UNITED KINGDOM Class 2 LED Modules, Models MS-P40XXX-XX Series, where XXX-XX may be any alphanumeric characters. 1. These LED panel of these products are powered by Class 2 power source rated at max. 15 VDC, 5 amps. 2. These products are suitable for use in dry and damp locations. 3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. 4. In the end product the LED face shall be protected from rain. ACROSENTEC CO LTD 253-9 GOCHUN-DONG E363566 UIWANG-SHI , GYEONGGI-DO 437-801 REPUBLIC OF KOREA Class 2 LED Modules, Models ASPCH-@*24-$-%-&, ASFCH-@-#-24-$-%-&, and ASMX-@-A-24-*-!, where @ can be any 2 to 4 alphanumeric code, # can be any 3 to 5 alphanumeric code, $ can be any 2 or 3 alphanumeric code, % can be any 1 to 4 alphanumeric code, & can be any 3 to 9 alphanumeric code, A can be any 3 to 5 alphanumenc code, * can be any 3 to 6 alphanumeric code, ! can be any 2 to 9 alphanumeric code. 1. These products are only suitable for connection to a Class 2 power source rated 27 V DC or less. 2. These products are intended for use only when connected to a power source that complies with Class 2 voltage and energy limited circuit limits and is rated 27 V DC or less. 3. When these units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating of the Class 2 supply. 4. These products are suitable for use in dry, damp and wet locations with supply sources rated at 27 V DC or less. 5. These products are not required to be enclosed or protected from the weather in the end product. 6. These products may be secured in place in the end product by any means available. ADHESIVE SYSTEMS INC E350958 9411 CORSAIR RD FRANKFORT, IL 60423 Polymeric adhesive system, Cat. No. MP55420. 1. The use of these adhesive systems shall be employed in applications wherein the limitations specified in Table A are not exceeded. 2. These systems may be used for securement to any combination of surfaces Listed in Table A, provided the use temperature is no higher than 71°C. sup€rior €1€ctrical adv€rtising, 1700 West Anaheim Street Long Beach, California 90813·1195 Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.com Project Australian Swim School Address: Village Way Santa Ana, CA. NiNGEViSiON 14 ou MASTER I.D._2€Lk_!11-3.11 Cynthia Uma/Gregg Grandon Account Manager. A--_zone Designer: G.P.M. Miller 3.50 hr DATE lit/1 6 EFr: 7 adrten Ave r iE 11 2.S /4 C Mead,Center d>' Scate:AS NOTED PLANNEF. Design No.: 12-08-5229-09 Date:08.15.12TRANSFERRED BY- DATE Revisions: Reg. No.: RS 03-20-13 mdm (1.5) change letterPLANNING INSPECTION -RED:rn-lkf and logo R4 04-12-13 aid (1.5) mvise & addROUGH___ FINAL -NONE- p %% !;1 specs, details & calcs. R5 04-15-13 aad (1.0) add window graphics. NAME-8.Id.Lne -40- _2*L -RS 05-10-13 aid (.5) add vinyl window U C wave band decals. R7 Jn (.25) 913/13 redosign linishing 14 vinyl-i %24 RS 05-31.13 aad (18) addl additional window graphics. RD 09.13-13 aad (.5) delete vinylRETAIN PLANE FOR FUTURE REVEONS. :02%3\ 1 window graphics. SUBJECT TO ITEMS CHECKED AND CONDITIONS 11* '4 Acct. Mgr, 4 4BELOW: 9 FOR JOB CHECK DATE O INTERIOR T? ONLY -,----i .L=£.PAM Acct. Mgr. FOR CONSTRUCTION DATEO NO EXTERION ALTERATiONS/MODIFICATIONS.O ALL MATERIALS TC MATCH EXISTING DesignO SCREENING REQUIRED Production O SUBMIT LANDSCAPE PLANS ./ Acct. Mgr. 1-FOR INSTALL ONLY DATE E EdNeL"-iCONDITIONS:-11 Page: 01 Of: 05 513 h 510 /3, 6 q 1 EPorno•:a SI 4%14044;.4-.9.T-M,/·V,/01.--3-»-A VICINITY MAPSCALE: NTS This ig an original uptished drawng created b,Superio,ElocuicalAdve,lis¥,g, Inc, Itis GESE?a;Brn fashion. The ch@noN of colors, mas.matorials or - melhoddoel not alle, the des, + Oanerhip d Ihis desi a hold ty, SL,lior Eleceical Adartilk,g, Inc Al*horizationt, use 5:Starm:23=1 © SEA 2012 Noto: The Color depicted here am a graphic represelation.Adual colon may valy. See color spocikations 1 . 55 FREEWAY Al sup€rior Electrical advertising, 1700 West Anaheim Street 1 Long Beach, California 90813-1195 :*MIMIwis 1 ---62-Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.comB142t-WA( J/1111 lillim-2- 1 Fl-1 I I M]'94 L 9&41{1111'll A Project Australian Swim School Address:-4---'Jnv 2.tt- 4- ME.2 14':e Village Way/ Santa Ana. CA. 140'.EEZiEWAY D /1 Account Manager: Cynthia Uma/Gregg Grandon Designer: M. Miller 3.50 :41:#al-r Scale:AS NOTED Design No. 12-08-5229-09 /7777777* 4 Leb\U:11)' 1/77/ &24u i 31 1 i 0 iiiiiimiiii / Date:08.15.12 Reg. No.: / Revisions:SOUTE VELAGE WAY R3 03-20-13 mdm (1.5) charge letter- and logoRA 04-12.13 aad (1.5) revise & add specs. details & calcs. RS 04-15-13 aad (1.0) add window „mt*L#w,/:a#frAV 1- graphics. Re 05-10-13 aad (.5) add vinyl window wave band decals. R7 Jn (.25) 5/13/13 Idesign (iNshing CS-31-13 aad (1.0) add additional window graphics. R9 09.13-13 aad (.51 delete vinyl window graphics. FOR JOB CHECK DATE lilill mid EltlilrILEFFEFFU-- 91 1111 JIll.PC Acct. Mgr. FOR CONSTRUCTION DATE Acct. Mgr. Design Production FOR INSTALL ONLY DATE 1.0.100 1 -Acct. Mgr. 420/ILL#.Wa ' -1.1111111119@&0 0111111111@U 1 1 .rT-1 ----1,U - |- Page: 02 Of: 05JE c2100·/PA:IUE 'i /00'll-1./. E m - .Fl*ILidilima):/ 211|114611|1111|FIll 0-401 tha des*: h ha My Superior ©SEA 2012 *2:.0/467/*..)..4.'/ See color speckatons. E. WILSHIRE AVENUE Ill Z Wall Area (12'-0" x 45'-6") = 546.0 Sq. Fl." 20% of 546.0 = 109.2 Max. Sign Sq. Fl." Sign (2'-81/4" x 27'-6") =73.91 Sq. Ft." Eq. L L. imille:I BUILDING H - WEST ELEVATION - FRONT - PROPOSED SIGN - SECONDARY SIGN SCALE: 3/16" = 1'-0" 45'-6" Fronlage sup€rior dEctrical adv€rtising¥ 1700 West Anaheim Street Long Beach, California 90813-1195 Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.com Project Australian Swim School Address: Village Way Santa Ana, CA. Account Manager. Cynthia Uma/Gregg Grandon Designer. M. Miller 3.50 Scale:AS NOTED Design No.: 1248-5229-09 Date:08.15.12 Reg. No.: Revisions: R3 03·20-13 mdm (1.5) change letter and logo R# 04-12-13 aid (1.5) revise & add specs. details & calcs. RS 04-15-13 aid (1.0) add window graphics. RS 05·10-13 aad (.5) add vhyl window wave band decals. R7 Jn (.25) 5/13/13 redesign finishing 05-31-13 aid (1.0) add additional window graphics. R9 09.13-13 aid (.5) delete vinyl window graphics. FOR JOB CHECK DATE Acct. Mgr. FOR CONSTRUCTION DATE Acct. Mgr. Design Production FOR INSTALL ONLY DATE Acct. Mgr. Page: 03 Of: 05 B an,ne '*sideot yol/orgal=l£:n, nor a it ID be repr*ced, copi«1 or exhiled in any ES'23;a 88cbical Adverti:ing, Inc. A:lhotiont, I. 11,1.ded.inany fashion must beobtained. wriling Dom Superior 80cbical Advertisig, Inc ©SEA 2012 :*15=5%*.*.44.** Soo color spedficalons 27'-6" 1 Eq. ; ,. .r 45'-6" Frontage Wall Area (12'-0" x 45'-6") = 546.0 Sq. Fl 20% of 546.0 =109.2 Max. Sign Sq. Fl Ul -4 654tf-. i A A ,# 917. i 1k .. 'U Sign (2'-894" x 27'-6") =T superior dfctrlcal advErtising] 1700 West Anaheim Street Long Beach, California 90813·1195 Phone: 562.495.3808 Facsimile: 562.435.1867 www.superiorsigns.com Project: Australian Swim School Address Village Way Santa Ana, CA. Account Manager:.. Cynthia Uma/Gregg Grandon Designer: M. Miller 3.50 Scale:AS NOTED Design No.: 12-08-5229-09 Date:08.15.12 Reg. No. Revisions: R303-20-13 mdm (1.5) change letter and kgo R40+12·13 aad (1.5)re m & add specs, delails & calcs RS 04-15-13 aad (1.0) add mndow graphics RS 05·10-13 aad (,5) add vinyt window wave band decals. R7 J n (.25) 5/13/13 redesign finishing vinyl R8 05·31·13 aad (1.0) add additional windowgiaphics R9 09·13·13 aad (.5) deletevinyl windowgraphics FOR JOB CHECK DATE Acct. Mgr, FOR CONSTRUCTION DATE Acct. Mgr. Design Production FOR INSTAU ONLY DATE Acd. Mgr. Page. 03 Of 05 BUILDING H - WEST ELEVATION - FRONT - PROPOSED SIGN - SECONDARY SIGN SCALE: 3/16" = 1'-0" staBd ic* m. 3440,/1 R 16 not lo be shown Eng:..4/.*&/lr=:11 ia6hroL Thechang,ng ofcolors slas: malerabor fiT=,f, method d- nol alle the *9 C..04, of =desgn • hekl b Super« Electric,Adie,ting Inc. ADthoruitonv" this de*,n e '35- null be obl-d nwrulg-AS,ZinrEledricA*-asm ll,c © SEA 2012 Wall Area (12'-0" x 45'-6") = 546.0 Sq. Ft." 40% of 546.0 =218.4 Max. Sign Sq. Ft." 1£71 Sign (2'-8'A" x 27'-6") =73.91 Sq. Ft.45'-6" Frontage z ddosupfrior Eq.27'-6" , 4 1700 West Anaheim Street Long Beach, California 90813-1195 Phone: 562.495.3808 i Facsimile: 562.435.1867 www.superiorsigns.com Ploject ./ ' 1----1 5 Australian Swim School 1404 Address, Village Way Santa Ana, CA. Account Manager: Cynthia Lima'Gregg Grandon Designer: M. Miller 3.50 Scale:AS NOTED Design No.: 12-08-5229-09 Date:08.15.12 Reg. No.: "Wbr'.095 =.t Revisions: R3 03-20-13 mdm t 1.5) change letter and bgo R4 04-12-13 •ad (1.5)rewse & add specs. details & Ics R504-15-13 aad (1.0) addwindow graphics, RBOS-10-13 a ad (.5) add vinylwindow wave band decals R7 J n (.25) 5/13t 13 redesign 8nishng vinyl Re 05-31·13 aid (1.0) add additional window graphics. R909-13-13 aad (,5) deletednyl noowgrapincs. FOR JOB CHECK DATE Acct. Mgr. :&91: FOR CONSTRUCnON DATE at·.,-,4-1 4/ L--R-,-i·.*Ji34€led?-flliff'.Siff)*9523#t, 6 -'1 ', - -Acct Mgr, Design 01--1 ,Prrwl i irk]Dn FOR INSTALL ONLY DATE Acct, Mgr. Page: 04 Of: 05 Via=*186 submllad fc*Your appro,&. 11 is nollo be shown * amme ouks,de of yo or,anizalon, nor i, itlote,Ip,oducedcogedereKhledinm! sh«, Thecha¥,gofcolofs /Ze/.malerb or RWninaton melhod doei not aller be de,ga O -sh,pol Ihs deggn s held Dy Superlof EIB*,ca Ad-t,ng inc U,orizton A use BUILDING H - EAST ELEVATION - REAR - PROPOSED SIGN - PRIMARY SIGNAGE hs de,glin am flhlon must be obtaned m -lng fin Supe,or Elac- Ad,le-g, Inc. ©SEA 2012 SCALE: 3/16" = 1'-0"No The Cok,s dapct0dhefe afe agidz Air©V[RaL[* ©©®©©L F.99.ter, 2'-814" 27'-6" 5 f f 7- 4-**USRALIAN SWIM SCHOOL 0 superior El«trical advertising: 1700 West Anaheim Street Long Beach, California- - I-- 4-4 91813-1195i Facsimile: 562,435.1,67 Phone: 562.495.3808 2 2 Equal 9'-47/8" SIGN ELEVATION / FACE LIT CHANNEL LETTERS AND LOGO "WAVE" PLAQUE QUANTITY: TWO (2) SETS REQUIRED SPECIFICATIONS: LETTERS:INTERIOR ILLUMINATED CHANNEL LETTERS & CHANNEL LOGO PLAQUE FACES:#7328 WHITE ACRYLIC PLASTIC WITH VINYL OVERLAYS WITH EXPOSED WHITE BORDER WAVE:#7328 WHITE ACRYLIC PLASTIC WITH VINYL OVERLAYS WITH EXPOSED WHITE BORDER TRIMCAPS:¥4" WHITE TRIMCAPS RETURNS:5" DEEP WHITE PRE-COATED ALUMINUM RETURNS ILLUMINATION:WHITE LED MODULES WITH REMOTE POWER SUPPLY ATTACHMENT:LETTERS TO BE INSTALLED FLUSH AGAINST WALL SURFACE NOTE:FIELD VERIFY ALL MEASUREMENTS AND CONDITIONS PRIOR TO ANY FABRICATION COLOR SPECIFICATIONS: 1 5--/ #7328 #230-33 PMS #3080 #230-127 #230-147 While Acrylic Red Vinyl Azure Blue Green Intense Blue Vinyl Lt. Euro Blue Vinyl Note to All Contractors Sign Voltage This sign is intended to be installed in accordance withthe requirements of Article 600 of the National Electrical Code and/or other applicable local codes. This includes proper grounding and bonding of the sign. All wall penetrations to be seated with UL Listed silicone sealant SECONDARY POWER- Equal PLEASE REFER Te THE NUMIEREI ITEMS IELOW FIR INCIRPIRATEI INSTALLINSTRUCTIONS. LISTEI INSTRUCTIONS Te BE FIUNI WITH ACTUAL SIGNAGE (NUMIEMEI ITEMS CIRRESPINI TO SECTIIN IETAIL) ITEM#PTI 1 LIGHT MITTING DIODES LED:) 2 DISCONNECT SWITCH 3 THREADED NIPPLE AND COUPLING (FLE][ CONNECTOR) 4 CLASS 2 LOW VOLTAGE WIRING (NO CONDUIT REQUIRED) 5 POWER SUPPLY 6 FLEX (FLEXIBLE CONDUm/UQuionetrr coNNECTIONS mAIN POWER' GROUNDING WIRE --RIMARY POWER 11 -EUTRALWIRE - POWERSUFFLY SIDE VIEW SCALE: 3/8" = IYPICAL WAL FRAMING - 1YPICAL WALL SURFACE -1: 040 ALUMINUM RETURNS TRIMCAP WITH #8 X 'h'SCREWS -3 i U UGHT EMITTING DIODES (LEDs) LOWVOLTAGE WIRING FROMLED TOLED ACRYL1C FACES m 1 - 1 040 ALUMINUM BACKS - DRILLED HOLE THRU WALL - '1 - FOR WIRE CONNECTIONS AND - FILLED WITH SILICONE TO PREVENT < C WATER PENETRAnON THREADED NIPPLE AND COUPLING - 20A 120-277VAC DISCONNECT SWITCH HANDY BOX »i. ¤ FLEX (FLEXIBLE CONDUIT) /LIQUID TIGHT CONNECnONS , Sq. Ft. = 73.91 SCALE: 3/8" = 1'-0" www.superiorsigns.com Project: Australian Swim School 1'-0"Address village Way Santa Ana, CA. Account Manager: Cynthia Urna/Gregg Grandon Designer: M. Miller 3.50 Scale:AS NOTED Design No.: 12-08-5229-09 Date:08.15.12 Reg. No. Revisions: R3 03-20-13 mdm (1.5 } change letter and logo R404·12·13 aad (1.5)rewse & add specs. details & /Ics. RS 04-15·13 *ad (1.0)addvAndow1 graphics. RS 05-16-13 lad (.5) add vinyl window wave band decaIs R7 Jn (.25) 91313 redesign finishing vinyl R8 0531-13 aad (1.0) add additional mndowgraphis. / CLASS 2 LOW VOIJAGE R9 09.13•13 and (.5) delete vinyl w,ndo. graphics,/WIRING (NO CONDUITJ REQUIRED) FOR JOB CHECK DATE1 1 4-WER Acct Mgr. SUPPLY FOR CONSTRUCTION DATE Acct. Mgr. DesignJ-BOXWITH 120-277VAC Production l DISCONNECT SWITCH FOR INSTALL ONLY DATE Acct Mgr. -· DISCONNECT SWITCH AT FAR LEFT OR RIGHT OF END LETTER •VERIFY PLACEMENT PRIOR TO FABRICATION LETTER LAYOUT - PLAN VIEWNOT TO SCALE #10 x 3 'h· DRZVE SCREWS MINIMUM THREE (3) PER LETTER ---r--1'OR AS REQUIRED PER FIELD CONDITIONS 1 4 ONE (1) 9.' WEEP HOLE - R LOCATED AT ALL AREAS THAT MAY COLLECT WATER \-4-_J TYPICAL SECTION DETAILSCALE: NTS Page: 05 Or 05 PWMARY POWER Nallit "be*-cd c,edle*hb»dll'ition Thedw¥,0 0! colors 918% mairih I ji.Inato m.mod does notla. the de,ga 0/i,*pdoldes,gnsheldby Supenor Elecinci Adwts,lg. 1-. AL*ho,e*on B Ke uidarmer'Dign MANNAA••dn wful, from S#er•y Eectica Ad,-ng k ©SEA 2012 Noe. 8 301 depad 1- am a Vaphic =1:2=*0*8!y V., 2'-8'A" Cily-ofianta-knaCE_*CEC_2010 , n (4) screws per letter, n 24"' on center, 2 ion, #10 sheet metal screws, & rain holes per letter Minimul ' maximuO A local disconnect for the monument sign(s) is penetralrequired or the dedicated circuit breaker(s) must (2) ¥4" dbe individually lockable in the off position. EC 600-6 .ccess to any power supply in attic or aboveorceiling shall be immediately from a ladderth a2x3 foot access door & passage with a\ill12-inch walkway. CEC 600-21 (d)(d)City of Santa Ana Planning & Building Agency ELECTRICAL 1. PLAN APPROVAL This set of plans and spec!ficaueng must be hipt on the job at all times and it Is unlawful to meke anyChanges or afterations on same without wittten per-, mission from the Department of Building Safety8 ·City of Santa Ana' The approval of this plan and specmcations SHALLNOT be held to permit nor be an approval of theviolation or any provisions of ANY City Ordlnanoeor State Law. CITY OF SANTA ANA1 DEPARTMENT OF BUILDING=SAFETY ' V- R i PERMITTYPE PLBG M®H GRADING PERMR#Rlf.]963920 152-WL-15 OCC. GROUP .-. CONSTR. TYPE CODE EDiTION 62010 FLOOD ZONF FLOOD ZONE GERTIE REQ'D YES Ne..h MICROFILM YES 4 RADIANT BARRIER @ ROOF YES NO RESIDENTIAL DEV. FEE YES NO i SCHOOL DISTRICT YES NO u --· ·· 42»ea= O. 4.