Loading...
HomeMy WebLinkAbout550 S Harbor Blvd - Misc. Permit/o/ for/ 0 E Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box'1988 (M-19) Santa Ana, CA927O2 (714) 647.5800 w\,vu/.santa-ana.org RESIDENTIAL PHOTOVOLTAIC CHECKLIST sol-o1 cBc 2013 Project Address: Contractor Company Name: Gontractor License Number: SOUTHWEST SUN SOLAR, INC 1004667 Are the following applicable to the ProPosed project? Will the PV system layout provide the required three-fool wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? Will the PV system be installed on a roof having only one rooling layer with no overlays? Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? Will the PV system weigh maximum 4 pounds per square feet or less? Wll the PV system be inslatled where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? Will the PV system be inslalled with a space of 2" minimum to 10" maximum betlveen the underside of modules and the surface of the roof? Will the PV system be installed without uslng any ballast system or counter-weight system? Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch embedment into roof rafters (wilh pre-drilled holes) and is this minimum embedment shown on the plans? Are ALL the slructural pages of the plans WET stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer's PV support ion.) I certify under penalty of perjury under the laws of the State of California above is true TRANG CONG PHAIV1 Phone Nurnber 714 582 3909 Date Email Address 1 YES NO B tr 3 Ettr 8tr Etr Etr atr 4 6 7 8 I trtr Etr AD 10 Etr I *-SNTA NA,"ffi Rev An712015 PERrV rT@SOUTHWESTSUNSOLAR.COTM Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only lnstructions: The llcensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of Plans, of minimum 1 1" x 17" size. lf answerinq NO to anv of lhe questions. plan check shall be required. 550 S. HARBOR BLVD, SANTA ANA, CA 92704 Print Name:Signature: