RESIDENTIAL
PHOTOVOLTAIC
CHECKLIST
sol-o1 cBc 2013
Project Address:
Contractor Company Name:
Gontractor License Number:
SOUTHWEST SUN SOLAR, INC
1004667
Are the following applicable to the ProPosed project?
Will the PV system layout provide the required three-fool wide clear access pathways
per Section 605.11 of the California Fire Code, and is this shown on the roof plan?
Will the PV system be installed on a roof having only one rooling layer with no
overlays?
Will the PV array be flush mounted to the existing roof so that the plane of the
modules (panels) are parallel to the plane of the roof?
Will the PV system weigh maximum 4 pounds per square feet or less?
Wll the PV system be inslatled where the modules do not overhang any roof edges
(such as eaves, gabled ends, ridges and hips)?
Will the PV system be inslalled with a space of 2" minimum to 10" maximum betlveen
the underside of modules and the surface of the roof?
Will the PV system be installed without uslng any ballast system or counter-weight
system?
Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet
and is this maximum horizontal spacing shown on the plans?
Will the minimum 5/16" lag screws be installed with a minimum of 2-112 inch
embedment into roof rafters (wilh pre-drilled holes) and is this minimum embedment
shown on the plans?
Are ALL the slructural pages of the plans WET stamped and signed by a California
licensed professional engineer? (including project specific site plan, PV layout,
anchorage spacing, anchorage details and manufacturer's PV support ion.)
I certify under penalty of perjury under the laws of the State of California above is true
TRANG CONG PHAIV1
Phone Nurnber 714 582 3909 Date
Email Address
1
YES NO
B tr
3
Ettr
8tr
Etr
Etr
atr
4
6
7
8
I
trtr
Etr
AD
10 Etr
I
*-SNTA
NA,"ffi
Rev An712015
PERrV rT@SOUTHWESTSUNSOLAR.COTM
Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only
lnstructions: The llcensed contractor of record shall complete all sections, answer the ten questions and
sign the certification section below. A copy of this form shall be attached to each of TWO sets of Plans, of
minimum 1 1" x 17" size. lf answerinq NO to anv of lhe questions. plan check shall be required.
550 S. HARBOR BLVD, SANTA ANA, CA 92704
Print Name:Signature: