Loading...
HomeMy WebLinkAbout1024 W Sharon Rd - PlanREV: H AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: CS-01DATE: 05/09/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 AERIAL MAP VICINITY MAP HOUSE VIEW COVER SHEET MICHAEL LANGSTON & CHRISTOPHER CLEARY - 10.935kW DC, 7.830kW AC, 9.855kW CEC AC RATING, 20.16kWh ENERGY STORAGE SYSTEM APPLICABLE CODES · ELECTRIC CODE:CEC 2022 · FIRE CODE:CFC 2022 · BUILDING CODE:CBC 2022 · RESIDENTIAL CODE:CRC 2022 10935W DC, 7830W AC, 9855W CEC AC RATING, 20.16 kWh ENERGY STORAGE SYSTEM SCOPE OF WORK BATTERY: INVERTER: MODULES: SYSTEM SIZE: (2)ENPHASE ENCHARGE 10 (ENCHARGE-10-1P-NA) (1)ENPHASE IQ SYSTEM CONTROLLER 2 (EP200G101-M240US01) (27) HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) (27) ENPHASE IQ8PLUS-72-2-US (240V) [SI-1] MAIN BREAKER DERATE:REPLACE EXISTING MAIN BREAKER WITH NEW 175A MAIN BREAKER 1. MODULES ARE LISTED UNDER UL 1703 / 61730 AND CONFORM TO THE STANDARDS. 2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6. ALL CONDUCTORS SHALL BE 600V, 90°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING. GENERAL NOTES BRANCH DETAILS: 1X9, 1X9, 1X9 ENPHASE BRANCHES RISK CATEGORY- ll BASIC WIND SPEED = 95 MPH @ 3-SEC GUST GROUND SNOW LOAD = 0 PSF DESIGN CRITERIA PROJECT WINDSPEED DETERMINED USING THE ASCE 7 STANDARD UNLESS DIRECTED OTHERWISE BY LOCAL JURISDICTION AMENDMENTS ROOF AREA CALCULATION TOTAL ARRAY AREA = 570.26 sq.ft TOTAL ROOF AREA = 3329 sq.ft % ARRAY AREA IN ROOF = 17.13 % SHEET CATALOG SHEET REVISION DESCRIPTION CS-01 COVER SHEET CS-02 GENERAL NOTES E-01 SITE PLAN S-01 MOUNTING DETAILS S-02 STRUCTURAL DETAILS E-02 SINGLE LINE DIAGRAM E-03 ELECTRICAL CALCULATIONS E-04 EQUIPMENT ELEVATION VIEW-1 E-04.1 EQUIPMENT ELEVATION VIEW-2 E-04.2 LOAD CALCULATION E-04.3 PANEL SCHEDULE PL-01 PLACARDS SS SPEC SHEET(S) H H H H H H H H H H SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder H H H B The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101118486 Elec# 20182270 APPROVALS: ELEC - MSmith 1024 W Sharon Rd - 201822705/28/2024 REV: E AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: CS-02DATE: 12/06/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 GENERAL NOTES INSTALLATION NOTES: 1.STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTOR WHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. 2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. 3.LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. 4.ALL PV RACKING ATTACHMENTS SHALL BE STACKED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. 5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6.ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 8.ALL SOLAR PANEL ARRAY COMPONENTS SHALL BE INSTALLED PER THE MANUFACTURER'S APPROVED INSTALLATION SPECIFICATIONS. 9.THE EXISTING BUILDINGS STRUCTURE SHALL BE VERIFIED AS PROPERLY CONSTRUCTED AND MAINTAINED IN GOOD CONDITION. NO ALLOWANCE HAS BEEN MADE IN THESE DRAWINGS FOR ANY EXISTING DEFICIENCY IN DESIGN, MATERIAL, CONSTRUCTION, OR LACK OF MAINTENANCE FOR THE EXISTING STRUCTURE OR PROPOSED EQUIPMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS, PROPER FIT, AND CLEARANCES IN THE FIELD. 10.WATERPROOFING AROUND THE ROOF PENETRATIONS IS THE RESPONSIBILITY OF CONTRACTOR/INSTALLER. 11.MISCELLANEOUS ITEMS NOT EXPLICITLY LISTED OR IDENTIFIED IN THESE DRAWINGS HAVE NOT BEEN DESIGNED. IT IS RECOMMENDED THAT MATERIAL OF SUITABLE SIZE STRENGTH TO BE OBTAINED FROM A REPUTABLE MANUFACTURER FOR MISCELLANEOUS ITEMS. 12.IF ANY CONDITION THROUGHOUT THE ASSOCIATED REPORT OR PERMIT DRAWINGS IS NOT ALSO REPRESENTED ON-SITE, CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES AND RECEIVE WRITTEN APPROVAL FROM THE ENGINEER OF RECORD BEFORE PROCEEDING WITH INSTALLATION. 13.CONTRACTOR TO PROVIDE MINIMUM 1/4" GAP BETWEEN ALL SOLAR PANELS. ROOF ACCESS PATHWAYS AND SETBACKS: 1205.2.1 SOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3 BUILDINGS SOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS  1205.2.1.1 THROUGH 1205.2.3. EXCEPTIONS: 1. THESE REQUIREMENTS SHALL NOT APPLY TO STRUCTURES DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE CALIFORNIA RESIDENTIAL CODE. 2. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL (16.7-PERCENT SLOPE) OR LESS. 1205.2.1.1 PATHWAYS TO RIDGE NOT FEWER THAN TWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36-INCH-WIDE (914 MM) PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. 1205.2.1.2 SETBACKS AT RIDGE FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS  OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 1205.2.1.3 ALTERNATIVE SETBACKS AT RIDGE WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITHIN THE DWELLING IN ACCORDANCE WITH SECTION 903.3.1.3, SETBACKS AT THE RIDGE SHALL CONFORM TO ONE OF THE FOLLOWING: 1. FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 2. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (914 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 1205.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS: PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS SHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. A PATHWAY OF NOT LESS THAN 36 INCHES (914 MM) WIDE SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder 1024 W Sharon Rd - 201822705/28/2024 AC B A A A A A A A A A BBB C B BB BB CCC CCCCC MS P BT CT CB JB AC RS D BT SBSB REV: H AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: E-01DATE: 05/09/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 SCALE:1"=20'-0"SITE PLAN MICHAEL LANGSTON & CHRISTOPHER CLEARY - 10.935kW DC, 7.830kW AC, 9.855kW CEC AC RATING, 20.16kWh ENERGY STORAGE SYSTEM 10935W DC, 7830W AC, 9855W CEC AC RATING, 20.16 kWh ENERGY STORAGE SYSTEM SCOPE OF WORK BATTERY: INVERTER: MODULES: SYSTEM SIZE: (2)ENPHASE ENCHARGE 10 (ENCHARGE-10-1P-NA) (1)ENPHASE IQ SYSTEM CONTROLLER 2 (EP200G101-M240US01) (27) HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) (27) ENPHASE IQ8PLUS-72-2-US (240V) [SI-1] MAIN BREAKER DERATE:REPLACE EXISTING MAIN BREAKER WITH NEW 175A MAIN BREAKER ROOF AREA CALCULATION TOTAL ARRAY AREA = 570.26 sq.ft TOTAL ROOF AREA = 3329 sq.ft % ARRAY AREA IN ROOF = 17.13 % BRANCH DETAILS: 1X9, 1X9, 1X9 ENPHASE BRANCHES SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder (E) UTILITY METER WITH (E) MAIN SERVICE PANEL (EXTERIOR) (N) (1)ENPHASE ENCHARGE 10 (EXTERIOR) (N) ENPHASE RAPID SHUTDOWN SWITCH (EXTERIOR) CONDUIT RUN PERIMETER FENCE GATE 1'-6" FIRE SETBACKDR I V E W A Y SHARON RD (N) JUNCTION BOX (ROOF-MOUNTED) DETACHED STRUCTURE (N) (1)ENPHASE ENCHARGE 10 (EXTERIOR) NOTE: 1. INDICATE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE IN FRONT OF DISCONNECTING MEANS, NOT BE LESS THAN 3 FOOT DEEP BY 2.5 FEET-WIDE FROM STANDING SURFACE TO NOT LESS THAN 6.5 FEET IN HEIGHT. NOTE: 1. EXTERIOR ESS UNIT(S) WILL NOT BE INSTALLED WITHIN 3 FEET (IN ANY DIRECTION) OF ANY DOORS, WINDOWS, OPERABLE OPENINGS INTO BUILDINGS AND HVAC INLETS. (N) ENPHASE IQ COMBINER 4/4C (EXTERIOR) (E) SUB PANEL-1 (INTERIOR) RESIDENCE STRING CONFIGURATION BRANCH DETAILS A 9 MICROINVERTERS B 9 MICROINVERTERS C 9 MICROINVERTERS TOTAL NUMBER OF STORY: 1 147'-10" 140'-4" 79'-9" GATE GATE GATE POOL DETACHED PERGOLAS PERGOLA 47'-4" 36'-4" 5'-5" WALKWAY WA L K W A Y WA L K W A Y WA L K W A Y 3'-1" (N) ENPHASE IQ SYSTEM CONTROLLER 2 (EXTERIOR) (N) ESS DISCONNECT (EXTERIOR) (N) AC DISCONNECT (EXTERIOR) (E) SUB PANEL-2 (INTERIOR) B 1024 W Sharon Rd - 201822705/28/2024 AC MSP BTCTCB JB ACRSD BT SB SB REV: H AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: PL-01DATE: 05/09/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 PLACARDS 1024 SHARON RD, SANTA ANA, CA 92706 PHOTOVOLTAIC ARRAY ON THE ROOF INSTALLED ON: DC DISCONNECT, INVERTER [TO BE USED WHEN INVERTER IS UNGROUNDED] ! WARNING! ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED INSTALLED ON: AC DISCONNECT, POINT OF INTERCONNECTION APPLICABLE CODE(S): CEC 690.13 ! WARNING! ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING-ELECTRIC SHOCK HAZARD NO USER SERVICEABLE PARTS INSIDE CONTACT AUTHORIZED SERVICE PROVIDE FOR ASSISTANCE INSTALLED ON: INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT SOLAR DISCONNECT INSTALLED ON: DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC690.13(B) SYSTEM UTILIZES MICROINVERTERS LOCATED UNDER EACH SOLAR MODULE INSTALLED ON: AC DISCONNECT(S), POINT OF INTERCONNECTION. APPLICABLE CODE(S): CEC 690.54 RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 32.67 240 PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH AMPS AC VAC CAUTION:MULTIPLE SOURCES OF POWER 1.PLACARDS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS. 2.PLACARDS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS. 3.PLACARDS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD. 4.PLACARDS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL BE HANDWRITTEN. 5.PLACARDS SHALL NOT COVER EXISTING MANUFACTURER LABELS. POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN NOTES LABEL LOCATION SERVICE PANEL PER CODE: CEC 705.10 !! TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRICPV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN INSTALLED ON: WITHIN 3 FT OF SERVICE DISCONNECTING MEANS. MIN 3/8" BLACK TEXT ON YELLOW BACKGROUND & 3/16" BLACK TEXT ON WHITE BACKGROUND. APPLICABLE CODE(S): CEC 690.56(C) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM INSTALLED ON:RAPID SHUTDOWN SWITCH APPLICABLE CODE(S): CEC 690.56(C)(2) INSTALLED ON: COMBINER PANEL DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL NO LOAD SHALL BE ADDED TO THIS PANEL THE MAIN BREAKER IN THIS PANEL HAS BEEN DERATED TO 175A DO NOT INSTALL LARGER BREAKER SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder JUNCTION BOX ! THREE POWER SOURCES ! SOURCES: UTILITY GRID, BATTERY AND PV SOLAR ELECTRIC SYSTEM WARNING INSTALLED ON: POINT OF INTERCONNECTION APPLICABLE CODE(S): CEC 705.12(C) INSTALLED ON: BATTERY DISCONNECT APPLICABLE CODE(S): CEC 480.7(F) & 706.15(C) ENERGY STORAGE SYSTEM DISCONNECT NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: 240V 73.5V ESS RAPID SHUTDOWN SWITCH ESS IQ COMBINER CONTROLLER (N) ESS DISCONNECT (EXTERIOR) (E) UTILITY METER WITH (E) MAIN SERVICE PANEL(EXTERIOR) (N) AC DISCONNECT (EXTERIOR) SUB PANEL-1 SUB PANEL-2 PCS CONTROLLED CURRENT SETTING: 20 AMPS THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURERE'S INSTRUCTIONS FOR MORE INFORMATION B 1024 W Sharon Rd - 201822705/28/2024 B A A A A A A A A A BBB C B BB BBCCC CCCCC REV: E AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: S-01DATE: 12/06/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 ALUMINUM RAILS 2 X 4 RAFTERS @ 2'-0"SPACING ARRAY MP-01SCALE:1"=10'-0" MOUNTING DETAILS S.NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.) ROOF EXPOSURE FRAME SPACING MAX RAIL SPANROOF TYPE ATTACHMENT FRAME TYPE MP-01 170° 24° 27 570.26 FLAT TILE FLAT TILE HOOK X ATTIC RAFTERS 2'-0" OVER HANG FRAME SIZE 2 X 4 6'-0" 2'-0" SITE INFORMATION NOTE: PENETRATIONS ARE STACKED ROOF AREA CALCULATION TOTAL ARRAY AREA = 570.26 sq.ft TOTAL ROOF AREA = 3329 sq.ft % ARRAY AREA IN ROOF = 17.13 % SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder 23'-11"43'-4"3' 6' 1'-6" 1'-6" 3'3' 1'-6" 1'-6" 3' 3' 24'-5" 2'-7" 20'-5" 1'-5" TOTAL NUMBER OF ATTACHMENTS: 50 TOTAL NUMBER OF STORY :1 STRING CONFIGURATION BRANCH DETAILS A 9 MICROINVERTERS B 9 MICROINVERTERS C 9 MICROINVERTERS 1024 W Sharon Rd - 201822705/28/2024 REV: E AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: S-02DATE: 12/06/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 STRUCTURAL DETAILS MODULE END CLAMPMID CLAMPMODULE DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 27 48.5 1309.5 MID-CLAMP 38 0.3 11.4 END-CLAMP 32 0.31 9.92 RAIL LENGTH 207 0.47 97.29 SPLICE BAR 10 0.65 6.5 FLAT TILE HOOK X 50 1.4 70 MICROINVERTERS 27 2.38 64.26 TOTAL WEIGHT OF THE SYSTEM (LBS)1568.87 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)570.26 WEIGHT PER SQ. FT.(LBS)2.75 WEIGHT PER PENETRATION (LBS)31.38 ROOF FRAMING DETAILS MID-CLAMP AND END-CLAMP ASSEMBLY MODULE DATA HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) MODULE DIM 74"x41.1"x1.26" LAG SCREW 5/16"x3.5":2.5" MIN EMBEDMENT SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder SCALE:NTS FLAT TILE ROOF (E) ROOF DECKING 6" MAX K2 CROSSRAIL 44-X MODULE (E) FRAMING SEE SHEET S-01 STAINLESS STEEL 5/16" LAG SCREWS 2.5" EMBEDMENT PILOT HOLE REQUIRED FLAT TILE HOOK X ATTACHMENT DETAIL-K2 FLAT TILE HOOK X 2 X 4 RAFTERS @2'-0" SPACING MODULE LOAD BEARING WALL SCALE:NTS 5/16" X 3.5" LAG SCREW 2 LAG SCREWS PER ATTACHMENT FLAT TILE ROOF BRACE (E) PURLIN MID CLAMP ASSEMBLY MODULE FRAME GROUNDING MID-CLAMP SCALE: NTS K2 CROSSRAIL 44-X RAIL K2 CROSSRAIL STRUCTURAL RAIL CONNECTOR T-BOLT SCREW SCALE: NTS MODULE TO MODULE & MODULE TO RAIL T-BOLT SCALE: NTS GROUNDING LUG GROUNDING DETAILS RAIL TO RAIL K2 CROSSRAIL 44-X RAIL 1024 W Sharon Rd - 201822705/28/2024 CONTROL PCBA AC COMBINER BREAKER IQ GATEWAY ENCHARGE BREAKER 50A 40A NC 2 NC 1 NO 2 NO 1 GEN-I/O AUTO TRANSFORMER MAINS RELAY LUG PV ESS NO 4 NO 3 (N)ENPHASE IQ CONTROLLER 2 (EP200G101-M240US01) (N)50A PV (N) 40A ESS SQUARE D DU222RB AC DISCONNECT NON FUSED 60A, NEMA 3R, 120/240V, 2P (N)60A AC DISCONNECT 3 (N)(2)ENPHASE ENCHARGE 10 (ENCHARGE-10-1P-NA) (BATTERY 20.16kWh) 4 (E)200A SUB PANEL-1 RELOCATED LOADS 5 40A 14 AWG CU WIRE (PER CEC 240.4(D)) 3 UTILITY GRID EXISTING 120/240V 1PH 60HZ METER#: SCE-SOUTHERN CALIFORNIA EDISON 222013-574774 M (E ) 1 7 5 A M A I N BR E A K E R (E)200A CENTER FED MAIN PANEL (N)175A 2P FEEDER BREAKER (E)GROUND ELECTRODE G N (N ) 1 7 5 A M A I N BR E A K E R 20A 20A IQ GATEWAY ENPHASE IQ COMBINER 4/4C X-IQ-AM1-240-4/4C 120/240V NEMA 3R INSTALL (3)20A 2P PV BREAKERS (ONLY FOR SOLAR, NO LOADS TO BE ADDED) (N)ENPHASE IQ COMBINER 4/4C (N)JUNCTION BOX DC CONDUCTORS AC CONDUCTORS MICROINVERTER (1) BRANCH OF (9) MICROINVERTERS (N)(9)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) MODULES WITH (N)(9)ENPHASE IQ8PLUS-72-2-US (240V) [SI-1] DC CONDUCTORS AC CONDUCTORS MICROINVERTER (1) BRANCH OF (9) MICROINVERTERS (N)(9)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) MODULES WITH (N)(9)ENPHASE IQ8PLUS-72-2-US (240V) [SI-1] 2 1 1 20A DC CONDUCTORS AC CONDUCTORS MICROINVERTER (1) BRANCH OF (9) MICROINVERTERS (N)(9)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) MODULES WITH (N)(9)ENPHASE IQ8PLUS-72-2-US (240V) [SI-1] 1 50A 2P RANGE & OVEN BREAKER 15A SQUARE D DU222RB ESS BLADE DISCONNECT NON FUSED 60A, NEMA 3R, 120/240V, 2P (N)60A ESS DISCONNECT 4 (N)ENPHASE RAPID SHUTDOWN SWITCH RSD 6 6 40A 2P A/C BREAKER 50A 2P SUB PANEL-2 BREAKER 20A 2P CLOTHES DRYER BREAKER 30A 2P POOL EQUIPMENT BREAKER 20A 1P POOL LITES BREAKER20A 1P POOL HOUSE BREAKER20A 1P OUTDOOR LITES XFMR BREAKER20A 1P GUEST, HRU T & M.BATHROOM BREAKER 20A 1P GARAGE MOTIN LIGHT BREAKER20A 1P GARAGE OUTLET BREAKER 20A 1P KITCHEN BREAKER 30A 1P FREEZER BREAKER 20A 1P DISHWASH BREAKER 20A 1PKITCHEN CIRCUIT BREAKER 20A 1P GUEST ROOM SOCKETS BREAKER 20A 1P FAM ROOM BREAKER 20A 1P MSTR BED BREAKER MODEL NO: LC020PC MURRAY TYPE G PANEL BOARD 200A MAXIMUN RATING 32 SLOTS (E)50A SUB PANEL-2 20A 1P BREAKER20A 1P BREAKER 20A 1P GARAGE DOOR OPERATOR BREAKER 20A 1P GARAGE WORBENCH BREAKER 20A 1P LIVING ROOM 20A 1P BREAKER20A 1P BREAKER20A 1P BREAKER 20A 1P BREAKER E 5 40A 2P A/C BREAKER PV BREAKER AS FAR AWAY FROM MAIN BREAKER AS POSSIBLE SINGLE LINE DIAGRAM DC SYSTEM SIZE- 10935W, AC SYSTEM SIZE - 7830W, CEC AC RATING - 9855W, 20.16 kWh ENERGY STORAGE SYSTEM NOTE: EACH MICROINVERTER IS RAPID SHUTDOWN COMPLIANT SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder CONDUCTOR AND CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 6 AWG BARE COPPER 2 3/4" EMT (6) 10 AWG THHN/THWN-2 NONE (1) 6 AWG THHN/THWN-2 3 3/4" EMT (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 4 3/4" EMT (2) 8 AWG THHN/THWN-2 NONE (1) 6 AWG THHN/THWN-2 5 1-1/2" EMT (2) 2/0 AWG THHN/THWN-2 (1) 2/0 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 6 3/4" EMT (2) 12 AWG THHN/THWN-2 NONE NONE REV: H AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: E-02DATE: 05/09/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 B MAIN BREAKER DERATE:REPLACE EXISTING MAIN BREAKER WITH NEW 175A MAIN BREAKER NOTE: PCS CONTROLLED CURRENT SETTING: 20 AMPS THE MAXIMUM OUTPUT CURRENT FROM THIS SYSTEM TOWARDS THE MAIN PANEL IS CONTROLLED ELECTRONICALLY. REFER TO MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION 1024 W Sharon Rd - 201822705/28/2024 REV: H AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: E-03DATE: 05/09/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 ELECTRICAL NOTES ELECTRICAL CALCULATIONS DC SYSTEM SIZE- 10935W, AC SYSTEM SIZE - 7830W, CEC AC RATING - 9855W, 20.16 kWh ENERGY STORAGE SYSTEM ENPHASE IQ8PLUS-72-2-US (240V) [SI-1] MICROINVERTER SPECIFICATIONS MODEL POWER RATING 290W MAX OUTPUT CURRENT 1.21A CEC WEIGHTED EFFICIENCY 97% MAX NO OF MICROINVERTERS / BRANCH 13 MAX DC VOLTAGE 60V 10.83 AMAX POWER CURRENT:Imp 11.17 ASHORT CIRCUIT CURRENT:Isc 37.39 VMAX POWER VOLTAGE:Vmp 45.34 VOPEN CIRCUIT VOLTAGE:Voc 405 WMODULE POWER @ STC MODEL MODULE SPECIFICATION HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) WIRE SIZE CALCULATIONS = 52.8 A = 40.84 A = 30.72 A = 13.61 A = 28.8 A = 13.61 A TAG 1: (AC) REQUIRED CONDUCTOR AMPACITY (1.21 * 9 * 1.25) CORRECTED AMPACITY CALCULATION (0.96 * 1 * 30) 13.61A < 28.8A TAG 2: (AC) REQUIRED CONDUCTOR AMPACITY (1.21 * 9 * 1.25) CORRECTED AMPACITY CALCULATION (0.96 * 0.8 * 40) 13.61A < 30.72A TAG 3: (AC) REQUIRED CONDUCTOR AMPACITY (1.21 * 27 * 1.25) CORRECTED AMPACITY CALCULATION (0.96 * 1 * 55) 40.84A < 52.8A AC WIRE SIZING CALCULATIONS BASED ON FOLLOWING EQUATIONS REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT * #OF INVERTERS = MAX CURRENT PER 690.8(A)(1)(e) * 125% = MAX CURRENT PER 690.8(B)(1) CORRECTED AMPACITY CALCULATIONS: DERATED CONDUCTOR AMPACITY PER 690.8(B)(2) = AMPACITY * TEMPERATURE DERATE FACTOR * CONDUIT FILL DERATE DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(1) < DERATED CONDUCTOR AMPACITY 1. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.10(C). 2. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.10(D). 3. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5. BREAKER/FUSES SIZED ACCORDING PER CEC ARTICLE 240. 6. AC GROUNDING ELECTRODE CONDUCTOR (GEC) SIZED PER CEC 250.66. 7. EQUIPMENT GROUNDING CONDUCTOR (EGC) SIZED PER CEC 250.122. 8. AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON TABLE CEC 310.15(B)(1). 9. CURRENT CARRYING CONDUCTOR ADJUSTMENT FACTOR IS BASED ON CEC 310.15(C)(1). 10. MAX. SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. 11. CONDUCTORS ARE SIZED PER CEC 310.16 . SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder B OCPD CALCULATION ALLOWABLE BACKFEED: MAIN PANEL RATING = 200 A MAIN BREAKER RATING = 175 A 100% RULE: = ((MAIN PANEL RATING * 1) - MAIN BREAKER RATING) = ((200 A*1)-175 A) = 25 A ALLOWABLE BACKFEED = 25 A INVERTER OVERCURRENT PROTECTION: INVERTER OVERCURRENT PROTECTION = (MICROINVERTER O/P CURRENT * # OF MICROINVERTERS * CONTINUOUS LOAD(1.25)) = (1.21 * 27 *1.25) = 40.84 A PV BREAKER = 50 A ≥ 40.84 A ESS BREAKER = 40 A ALLOWABLE BACKFEED 25A ≥ 20A CURRENT (WITH PCS CONTROL) ESS CALCULATION BATTERY = (16 * 2) * 1.25 = 40.00 A 1024 W Sharon Rd - 201822705/28/2024 SOUTH INTERIOR GARAGE WALL BACKYARD BACKYARD END OF WALL DOOR (E) SUB PANEL (E) SUB PANEL ELECTRICAL CLOSET REV: F AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: E-04.1DATE: 04/10/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder EQUIPMENT ELEVATION VIEW-2 SCALE:1/2" = 1'-0" NOTE: 1. INDICATE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE IN FRONT OF DISCONNECTING MEANS, NOT BE LESS THAN 3 FOOT DEEP BY 2.5 FEET-WIDE FROM STANDING SURFACE TO NOT LESS THAN 6.5 FEET IN HEIGHT. NOTE: 1. EXTERIOR ESS UNIT(S) WILL NOT BE INSTALLED WITHIN 3 FEET (IN ANY DIRECTION) OF ANY DOORS, WINDOWS, OPERABLE OPENINGS INTO BUILDINGS AND HVAC INLETS. A 1024 W Sharon Rd - 201822705/28/2024 REV: H AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: E-04.2DATE: 05/09/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder LOAD CALCULATION B 1024 W Sharon Rd - 201822705/28/2024 (E)200A / MUARRY - SUB PANEL-1 20A 20A 20A FAM ROOM MSTR BED 20A POOL E2 DISH WASH 50A 50A 30A 20A 30A 20A RANGE FREEZER POOL LITES OUTDOOR LITES GARAGE MOTION LIGHT GUEST BEDROOM SUB PANEL-2 SUB PANEL-2 GARAGE OUTLET KITCHEN LITES OVEN 20A 20A 30A POOL E2 CLOTHES DRYER 20A 20A POOL HOMES 40A 40A AIR CONDITIONER AIR CONDITIONER 20A 20A GUEST ROOM SOCKETS KITCHEN CIRCUIT 50A 50A 20A 20A (N) 175A MAIN BREAKER175A A/C40A 40A (E)200A - / SQUARE-D MAIN SERVICE PANEL (N) 175A MAIN BREAKER175A FEEDER BREAKER175A 175A (E)50A / ZINSCO - SUB PANEL-2 GARAGE WORKBENCH 20A 20A 20A 20A 20A 20A 20A 20A 20A GARAGE DOOR OPERATOR LIVING ROOM REV: H AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: E-04.3DATE: 05/09/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder PANEL SCHEDULE B 1024 W Sharon Rd - 201822705/28/2024 EAST EXTERIOR WALL OF HOUSE STREET END OF WALL VENT WINDOWWINDOW BACKYARD (E)MAIN SERVICE PANEL ENPHASE (N) ENPHASE IQ COMBINER 4/4C (N) AC DISCONNECT (N) ESS DISCONNECT ENPHASE (N) ENPHASE IQ SYSTEM CONTROLER 2 WEST EXTERIOR WALL OF HOUSE STREET BACKYARD DOOR VENT ENPHASE (N) ENPHASE ENCHARGE 10 GATE END OF WALL GATE ENPHASE (N) ENPHASE ENCHARGE 10 Enphase Energy System Shutdown Switch (N) ENPHASE RAPID SHUTDOWN SWITCH REV: F AHJ: CA-CITY OF SANTA ANA 33.770878, -117.879538 APN: 00123127 NAME: MICHAEL LANGSTON & CHRISTOPHER CLEARY DRAFTED BY: K.NISHANTH ADDRESS: 1024 SHARON RD, SANTA ANA, CA 92706 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-87593 PAPER SIZE: 17"X11"SHEET: E-04DATE: 04/10/2024 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: J.ABINESH PHONE NUMBER: (714) 225-5477 SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder EQUIPMENT ELEVATION VIEW-1 SCALE:3/8" = 1'-0" NOTE: 1. INDICATE DEDICATED CLEAR UNOBSTRUCTED WORKING SPACE IN FRONT OF DISCONNECTING MEANS, NOT BE LESS THAN 3 FOOT DEEP BY 2.5 FEET-WIDE FROM STANDING SURFACE TO NOT LESS THAN 6.5 FEET IN HEIGHT. NOTE: 1. SCALE:3/8" = 1'-0" A EXTERIOR ESS UNIT(S) WILL NOT BE INSTALLED WITHIN 3 FEET FROM DOORS, WINDOWS LEADING INTO THE HOME. 1024 W Sharon Rd - 201822705/28/2024 1024 W Sharon Rd - 201822705/28/2024 1024 W Sharon Rd - 201822705/28/2024 Rev: 2/17/2015 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2013 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall fill in the address of the project, contractor’s licensing information and answer questions 1 -10 below. Complete and sign the certification section. **If answering NO to any of the questions, plan check shall be required.** Project Address: ________________________________________________________________ Contractor Company Name: _______________________________________________________ Contractor License Number: _______________________________________________________ YES NO Are the following applicable to the proposed project? 1.  Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 2.  Will the PV system weigh maximum 3 pounds per square feet or less? 3.  Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 4.  Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 5.  Will the PV system be installed without using any ballast system or counter-weight system? 6.  Will the PV system be installed on a roof having only one roofing layer with no overlays? 7.  Will the PV system layout provide a three-foot wide clear access pathway per the latest edition of “Guideline for Fire Safety Elements of Solar Photovoltaic Systems” by OCFA? (Guideline available on the OCFA website: http://www.ocfa.org) 8.  Do the plans show a maximum horizontal anchor spacing of 6 feet? 9.  Do the plans show a minimum of 2-1/2 inch lag screw embedment into roof rafters? 10.  Are ALL the structural pages of the plans WET stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print name: ________________________________ Signature: _________________________ Phone Number: _____________________________ Date: _____________________________ Email Address: _________________________________________________________________ Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 1024 W Sharon Rd - 201822705/28/2024 1024 W Sharon Rd - 201822705/28/2024 FLUSH MOUNTED SOLAR PANELS Type of Roof Gable Roof Slope -  = Angle of plane of roof from horizontal, in degrees  =24 deg Mean Roof Height - Eave height will be used for  <= 10deg h = 15 ft Building dimensions s1 = 30 ft s2 = 30 ft a = 10% of least horizontal dimension or 0.4h, whichever is smaller, but not less than 4% of the least horizontal direction or 3 f a = 3 ft B = Horizontal dimension of building normal to wind direction, in ft. B = 20 ft Horizontal dimension of building Attachment Spacing Effective Area A = 15 ft2 p = qh(GCp)(E)(a)29.4-7 Velocity pressure Exposure Coefficient ROOF OVERHANG Wind Exposure C (GCp)down = 0.49 0.49 Kzt =1 (GCp)upz1 = -1.5 -2 Kd =0.85 (GCp)upz2e = -1.5 -2 Kz =0.85 (GCp)upz2n = -2.31 -2.88 Ke =1 (GCp)upz2r = -2.31 -2.88 E =1 (GCp)upz3e = -2.31 -3.32 a = 0.73 (GCp)upz3r = -2.66 -3.5 V = 95 mph qh = 0.00256KzKztKdKeV2 qh = 16.7 psf p = 12.191 *(GCp) FIGURE 30.3-2C Components & Cladding h<= 60 ft: External Pressure Coefficients, (GCp), for Enclosed and Partially Enclosed Buildings - Gable roofs 20<=27deg ASCE 7-16 1 1024 W Sharon Rd - 201822705/28/2024 Wind Pressures Wind Down - All Zones 6 psf 10 psf, MIN ROOF OVERHANG Zone 1 -18.29 psf -24.38 psf Zone 2e -18.29 psf -24.38 psf Zone 2n -28.16 psf -35.11 psf Zone 2r -28.16 psf -35.11 psf Zone 3e -28.16 psf -40.47 psf Zone 3r -32.43 psf -42.67 psf All panels are in Zones 1 and 2e ROOF OVERHANG Use -18.29 psf -24.38 psf 0.6*W -11 psf -14.6 psf ASCE 7-16 2 1024 W Sharon Rd - 201822705/28/2024 Soil Site Class = D Risk Category = II SS = 1.462 Mapped Spectral Response acceleration in short periods S1 = 0.537 Mapped Spectral Response acceleration at one second periods SS< 0.25 SS= 1.0 SS>1.25 SS>1.5 0.8 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.3 1.2 1.2 1.2 1.6 1.1 1.0 1.0 2.4 - - - - - - - Fa = 1.200 (interpolated) SMS = Fa*SS = 1.754 Min. 1.2 per 11.4.3 S1< 0.1 S1= 0.4 S1>0.5 S1>0.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.5 1.5 1.5 1.4 2.4 1.6 1.5 1.7 4.2 - - - - - - - Fv = 1.574 (interpolated) SM1 = Fv*S1 = 0.845 SDS = 2/3 *SMS = 1.17 SD1 = 2/3 *SM1 = 0.563 SDS RISK CATEGORY SD1 RISK CATEGORY > I, II III IV > I, II III IV 0 A A A 0 A A A 0.167 B B C 0.067 B B C 0.33 C C D 0.133 C C D 0.5 D D D 0.2 D D D Seismic Design Category = D 1.5 1.5 B E - - F - - 2.2 2.0D C 0.8 0.8 1.3 Table 1613.2.3(2) 0.8 Values of Site Coefficient Fv S1= 0.2 S1= 0.3SITE CLASS 1.7 A 0.8 1.3 C E -F - 1.2 SITE CLASS SS= 0.5 SS= 0.75 A 0.8 0.8 B 1.2 0.9 D 1.4 0.9 ASCE 7-16 Table 1613.2.3(1) Values of Site Coefficient Fa 1024 W Sharon Rd - 201822705/28/2024 Seismic Use Group = I Seismic Design Category = D I = 1 SS = 1.462 S1 = 0.537 SMS = 1.754 SM1 = 0.845 R = 6.5 Height = 11.375 T = 0.035*hn^.75 = 0.21679 r (Reliability/Redundancy Factor) = 1 SDS = 1.17 SD1 = 0.563 (ASCE 7-16 12.8-2)Cs = SDS/(R/I) = 0.1800 W (ASCE 7-16 12.8-3)Cs <= SD1/[(R/I)T] = 0.400 W (ASCE 7-16 12.8-5)Cs >= .01 = 0.01 W If S1>0.6g (ASCE 7-16 12.8-5)Cs >= 0.5*S1/[R/I]= 0.000 W V(controls) = 0.1800 W Determine Fp for seismic loading on attachments Seismic Load on Nonstructural Components Spacing of attachments 6 ft Tributary width of attachments = 1/2 Panel length = 37 in Ap =18.5 ft PV unit weight including racking = 3 psf W p =55.5 lb Other mechanical/electrical components ap =1 Fp = 0.4apSDS*W p/(Rp/Ip)(1+2z/h)51.95 lb 13.3-1 Rp =1.5 Ip =1 Fp <= 1.6SDS*IpW p 103.90 lb 13.3-2 SDS = 1.170 Wp = 55.5 lb Fp >= 0.3SDS*IpW p 19.48 lb 13.3-3 z= 15 ft h= 15 ft ASCE 7-16 1024 W Sharon Rd - 201822705/28/2024 SHEET: 5 OF 7 DATE: DE JOB NO.: DESIGN LOADS Dead Loads Uplift Roof 0.6WL CONC. FLAT TILE 9.0 psf 0.6WL Zone 1 and 2e -11 psf, MIN 10 PSF 5/8" Ply shtg 1.9 Overhang -14.6 psf Rf Frm'g 2.8 pWLdown =6.0 psf 10 psf, MIN 10 PSF Misc. 1.5 Uplift 0.6DL+0.6WL (N) PV System 3.0 Zone 1 0.6*3 -11 -9.2 psf Zone 2 0.6*3 -14.6 -12.8 psf Total DL 18.2 psf Downward DL+0.6WL LL 20.0 psf PDL+WL =13.0 psf SNOW 0.0 psf Rafter Check Existing 2x4 RAFTERS @ 24" o.c Spacing 2.00 ft Trib panel width = 6 ft E 1500000 psi Fb =900*1.5*1.15 1552.5 psi I 5.4 in^4 MallowWind =1110 ft-lb Span1 10.00 ft MallowLL =867 ft-lb Span2 10.00 ft See below for Wind Uplift loads Span3 0.00 ft due to concentated loads at attachments Span4 0.00 ft (Distance to Att. Pts)a b R1 (lb) R2 (lb Load (psf) Trib W (ft) Wind Uplift (lb) Mmax wind(ft- lb) Wind Down (lb) P = PVDL (lb) 0.00 1 0.91 0.91 9.09 185.0 18.5 11 6.0 203.5 168 185 55.5 240.5 2 4.72 4.72 5.28 107.4 96.1 11 6.0 203.5 507 185 55.5 240.5 3 6.55 6.55 3.45 70.2 133.3 11 6.0 203.5 460 185 55.5 240.5 4 10.35 0.35 9.65 196.4 7.1 11 6.0 203.5 69 185 55.5 240.5 5 12.18 2.18 7.82 159.1 44.4 11 6.0 203.5 347 185 55.5 240.5 6 15.99 5.99 4.01 81.6 121.9 11 6.0 203.5 489 185 55.5 240.5 16.90 Span 1 Uniform DL 10.00 91.2 91.2 9.1 psf 2.0 18.2 plf 228 Span 2 Uniform DL 10.00 91.2 91.2 9.1 psf 2.0 18.2 228 Reactions at Span1 453.8 339.1 Negative values are uplift reactions Reactions at Span2 287.6 98.3 Mmaxwindup = 451 ft-lb < 1110 ft-lb OK Mmaxwinddown = 1085 ft-lb < 1110 ft-lb OK For DL+LL including the PV system weight point loads w = 70.4 plf P = 55.5 lb Mmax =847 ft-lb < 867 ft-lb OK Deflection Check DDL = 5wL4/(384EI)(5*18.2*10^4)*1728 = 1.019 in = L/ 117.8 OK 384*1.5E6*5.4 PROJECT: CLIENT: BY: PV Panels for Christopher Cleary & Mich Solar Max Renewable Energy Provider, I Doug Engineering 1/4/2024 SMX-11152 P = DL+WL (lb) 1024 W Sharon Rd - 201822705/28/2024 SHEET: 6 OF 7 DATE: DE JOB NO.: CHECK SCREW ATTACHMENTS FOR WIND UPLIFT Pwuplift =203.5 lb 5/16" Lag with min 2.5" penetration for each attachment Table 12.2A - NDS - Lag Screw Withdrawal Values For 5/16" Lag into .5G wood 266 lb Allowable wind load = 1.6*2.5*266 1064 lb > 203.5 lb OK CHECK SCREW ATTACHMENTS FOR SHEAR DUE TO SEISMIC Fp Fp = 51.95 lb Roof slope/module tilt 24 deg Shear = Fp*cos( 24 ) = 47.5 lb Fp sin(ang) Tension = Fp*sin( 24 ) = 21.1 lb Fp cos(ang) Table 11K - NDS Z = 190 lb CD = 1.6 ` Z' = Z*CD =304 lb > 47.46 lb OK Withdrawal capacity W' = 1064 lb Interaction Equation ft/Ft+fv/Fv 0.211 + 0.156 = 0.367 < 1 OK RAIL SPAN CHECK K2 Crossrail Railing Check - Gable/Hip Roof Load for half a panel = 2.7' W =57.78 plf Per the K2 Engineering for 95 mph, 0 psf snow, and 24 deg roof slope, the max span for 44X Dual Rail is 82" for Array Interior Panels and 74" for Array Array Edge panels Use K2 44X Dual PV Rails with a spacing of 7" o.c. max for attachment points, typ. PROJECT: CLIENT: BY: PV Panels for Christopher Cleary & Michael Solar Max Renewable Energy Provider, Inc. Doug Engineering 1/4/2024 SMX-11152 1024 W Sharon Rd - 201822705/28/2024 SHEET: 7 OF 7 DATE: DE JOB NO.: LATERAL ANALYSIS DETERMINE ADDITIONAL LOAD COMPARED TO EXISTING FOR LATERAL LOADING Aroofexisting== 3329 sf W panel =48.5 lb W roofexisting =15.2*3329 = 50601 lb 27 *W panel = 1309.5 lb W wallexisting =15*80*4 = 4800 lb W restofarray =399.6 lb W existing =55401 lb W array = 1709.1 lb V = 0.18 W Vroofexisting =9972 lb Existing Total Lateral Force Vroofwpanels =10280 lb New Total Later Force % increase = 10280 increase which results in less than a 10% increase in the 9972 stress of existing lateral resisting elements OK BY: Doug Engineering SMX-11152 PROJECT: PV Panels for Christopher Cleary & Michael CLIENT: Solar Max Renewable Energy Provider, Inc. 1/4/2024 *100%-100% = 3% 1024 W Sharon Rd - 201822705/28/2024 MODULE SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 INVERTER SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 ATTACHMENT SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 RACKING SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 BATTERY SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 COMBINER SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 SMART SWITCH SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 AC DISCONNECT SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 BONDING AND GROUNDING SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 ENGINEERING LETTER 1024 W Sharon Rd - 201822705/28/2024 ENGINEERING LETTER 1024 W Sharon Rd - 201822705/28/2024 Q CABLE ACCESSORIES SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 RAPID SHUTDOWN SWITCH SPEC SHEET 1024 W Sharon Rd - 201822705/28/2024 BATTERY MOUNTING REQUIREMENTS SHEET B 1024 W Sharon Rd - 201822705/28/2024