Loading...
HomeMy WebLinkAbout1118 S Hickory St - PlanMSPUM ACD ACB JB SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-9 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° APS CHART 1-10 1 2 3 4 11-20 21-30 31-40 41-50 51-60 5 6 7 8 9 10 APS CHART S H I C K O R Y S T . Structural Only R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TRUONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-10 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 11 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° MODULE SPEC SHEETS Structural Only R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TRU ONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-11 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 11 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° INVERTER SPEC SHEETS Structural Only R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PH ONG TRU ONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-12 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 11 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° RACKING SPEC SHEETS Structural Only R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TRUONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-13 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 11 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° RACKING SPEC SHEETS Structural Only R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TRUONG 1118 S Hickory St 06/05/23 9'-4" 24'-6" 7'-0"2" 1 2 ' - 7 " 4' - 5 " 1 0 ' - 9 " 3' - 5 " 1 5 ' - 7 " 8'-9" 6'-2" 7" MSPUM ACD ACB JB ROOF PLAN WITH MODULES SCALE: 3/32" = 1'-0"1 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-2 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° ROOF PLAN WITH MODULES · ALL EQUIPMENT AND CONDUITS SHALL BE PAINTED TO MATCH THE BACKGROUND COLOR OF THAT LOCATION. · PLUMBING VENTS, SKYLIGHTS AND MECHANICAL VENTS SHALL NOT BE COVERED, MOVED, RE-ROUTED OR RE-LOCATED. 74.0" 4 1 . 1 " 36 " FIRE CODE SETBACKS NOTE: THIS PLAN CHECK IS FOR SOLAR PHOTOVOLTAIC ONLY. OTHER STRUCTURES ON SITE ARE NOT A PART OF REVIEW. 1 8 " FIRE CODE SETBACKS M ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 8 168.96 354.01 47.73 #2 1 21.12 275.80 7.66 ROOF DESCRIPTION ROOF TYPE ASPHALT SHINGLE ROOF ROOF TILT AZIMUTH TRUSSES SIZE TRUSSES SPACING #1 18° 180° 2"x6" 24" O.C. #2 18° 270° 2"x6" 24" O.C. 2"X6" TRUSSES @ 24" O.C. (TYP.) MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF PANELS IN ARRAY = 9 MODULES MODULE TYPE = HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES NUMBER OF CONNECTIONS TO ROOF = 23 WEIGHT OF INDIVIDUAL PANEL = 48.5 LBS / 22.0 KG. MOUNTING SYSTEM WEIGHT : 1.5 LBS. PER MODULE TOTAL WEIGHT OF ARRAY: 450.00 LBS. WEIGHT AT EACH CONCECTION : 450.00 LBS / 23 = 19.57 LBS SOLAR PANEL AREA = 74.0"X 41.1 " = 21.12 SF TOTAL ARRAY AREA = 9 X 21.12 = 190.08 DISTRIBUTED LOAD = 450.00/190.08= 2.37 PSF 3/4" OR GREATER EMT CONDUITRUN (1/2 INCHES ABOVE ROOF) (N) JUNCTION BOX (E ) B A C K Y A R D (N) IRONRIDGE XR10 RAILS 168" (23) IRONRIDGE FLASH FOOT2 ATTACHMENTS @ 48" O.C. PHOTOVOLTAIC MODULES HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) (5) AP SYSTEM DS3-S MICROINVERTERS(240V) (E) UTILITY METER (N) AC COMBINER BOX (E) MAIN SERVICE PANEL, 200 (N) AC DISCONNECTROOF #2 (01) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES (E ) F R O N T Y A R D S H I C K O R Y S T . ROOF #1 (08) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES Structural Only R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TRUONG 1118 S Hickory St 06/05/23 STRING LAYOUT STRING LAYOUT SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-3 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° SCALE: 1/8" = 1'-0"1 74.0" 4 1 . 1 " 36 " FIRE CODE SETBACKS 1 8 " FIRE CODE SETBACKS BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 9 HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES INVERTER 5 AP SYSTEM DS3-S MICROINVERTERS(240V) AC DISCONNECT 1 30A NON FUSED ,240V NEMA 3R,UL LISTED ATTACHMENT 23 IRONRIDGE FLASH FOOT2 ATTACHMENTS RAILS 5 IRONRIDGE XR10 RAILS 168" RAIL SPLICE 2 SPLICE KIT MID CLAMPS 12 MID CLAMPS END CLAMPS 12 END CLAMPS GROUNDING LUG 3 WEEBLUG (5) AP SYSTEM DS3-S MICROINVERTERS(240V) PHOTOVOLTAIC MODULES HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) CIRCUIT #1 (E ) B A C K Y A R D (E ) F R O N T Y A R D S H I C K O R Y S T . Structural Only R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TR UONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-4 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° ATTACHMENT DETAIL SCALE: NTS 1 ATTACHMENT DETAIL (SIDE VIEW) PV-4 SCALE: NTS 1 ATTACHMENT DETAIL (SIDE VIEW) PV-4 SCALE: NTS 2 ATTACHMENT DETAIL ENLARGED VIEW PV-4 SCALE: NTS 2 ATTACHMENT DETAIL ENLARGED VIEW PV-4 ~6 " (E) ASPHALT SHINGLE SEE ENLARGED VIEW PV MODULE 2"X6" TRUSSES @24" O.C. 5/16"x3.5" SS LAG BOLT WITH MIN 21 2" THREAD EMBEDMENT, SEALED PENETRATION PV MODULES (E) ASPHALT SHINGLE IRONRIDGE XR10 RAIL IRONRIDGE INTEGRATED GROUNDING & END/MID CLAMP ALUMN. "L" BRACKET W/3/8" SS BOLT & NUT IRONRIDGE FLASH FOOT2 ATTACHMENTS FLASHING 2"X6" TRUSSES @24" O.C. Structural Only R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA P H ONG TRUONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-5 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° THREE LINE DIAGRAM ELECTRICAL SCHEMATIC SCALE: NTS1 UTILITY FEED + TOTAL BACKFEED 200A + 20A = 220A LESS OR EQUAL TO BUS RATING x 120% 200A x 120% = 240A INTERCONNECTION 120% RULE (MAIN PANEL) G N 1 2 1 2 ON OFF PV VISIBLE LOCKABLE LABELED DISCONNECT (30A UNFUSED 1PH 240VAC) MCB-01 LC-01 MS-01 LC-01 AC wire details WireID #Inverter Nominal Voltage Backfeed *1.25 /cond. set Min OCPD Total Power Conductor sets ccConductors /conduit Expected max temp Adjusted ampacity (ampacity x temp derate x conduit fill derate) Conductor & neutral size EGC size (Cu) Conductor metal Min EMT size MS-01 05 240 V 16.62 A 20 A 3.20 kW 1 2 31 30 x 0.96x 1.00 = 28.8 A 12 AWG PV 06 AWG BARE (NOT IN CONDUIT)Cu - MCB-01 05 240 V 16.62 A 20 A 3.20 kW 1 2 31 40 x 0.96x 1.00 = 38.4 A 10 AWG THWN-2 10 AWG THWN-2 Cu 3/4" LC-01 05 240 V 16.62 A 20 A 3.20 kW 1 2 31 35 x 0.94 x 1.00 = 32.9 A 10 AWG THWN-2 08 AWG THWN-2 Cu 3/4" SYSTEM SUMMARY STC DC/AC (3.60 KW DC / 3.20 KW AC) STC DC: (9) 400 = 3.60 KW STC AC: (05) 640 = 3.20 KW - (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES - (05) AP SYSTEM DS3-S (240V) MICROINVERTERS · 1X CIRCUIT OF 9 MODULES CONNECTED IN SERIES ELECTRICAL NOTES 1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. 5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL CECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CEC 690. 11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. 12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER CEC 310.15(B)(16). 1 1 2 G N 2 1 1 2 G 1 2 G N G N JUNCTION BOX 600V, NEMA 3R UL LISTED AC COMBINER PANEL 20(N) G N TO UTILITY GRIDM 200A(E) 20A(N) MAIN SERVICE PANEL (EXISTING, BOTTOM-FED) BUS RATING: 200A MAIN BREAKER: 200A (E) UTILITY METER UTILITY: SOUTHERN CALIFORNIA EDISON CO SERVICE: 240V 60HZ 1P MOD: HANWHA Q.PEAK DUO BLK ML-G10+ 400 INV: AP SYSTEM DS3-S-MICRO (240V) (1 CIRCUIT X 4 MICRO-INV(1:2)X1 MICRO-INV(1:1)) 09 Structural Only R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TRUONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-6 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° ELECTRICAL NOTES PV MODULE RATING @ STC MANUFACTURER MAX. POWER-POINT CURRENT (IMP) MAX. POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) 10.77 AMPS 37.13 VOLTS 45.30 VOLTS 11.14 AMPS NOM. MAX. POWER AT STC (PMAX) VOC TEMPERATURE COEFFICIENT 400 WATT -0.27° %/°K Q.PEAK DUO BLK ML-G10+ 400 16.APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTOR OR A COUNY OF SAN BERNARDINO SELF - CERTIFICATION FORM. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL BEDROOMS,OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE [R314.1,R315.1] 17.NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. ELECTRICAL NOTE: 1. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE 2022 CEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING ELECTRICAL UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. 2. BI-DIRECTIONAL UTILITY METER TO BE INSTALLED BY UTILITY COMPANY (WHEN REQUIRED). 3. BI-DIRECTIONAL UTILITY METER TO BE INSTALLED BY UTILITY COMPANY (WHEN REQUIRED). 4. LABEL BREAKER "PHOTOVOLTAIC ELECTRIC POWER SOURCE". PER CEC 705.10 AND "BREAKERS ARE BACKFED" PER CEC 690.64(B)(5). LABEL WITH THE MAXIMUM AC OUTPUT OPERATING CURRENT AND THE OPERATING VOLTAGE PER CEC 690.54. 5. LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT SWITCH" PER CEC 690.14(C)(2). LABEL WITH OPERATING CURRENT, OPERATING VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER CEC 690.53. SWITCH TO BE LOCKED PER CEC 690.7(d). 6. LABEL "PHOTOVOLTAIC POWER SYSTEM DEDICATED kWH METER". 7. PROVIDE WARNING SIGN PER CEC 690.17 READING "WARNING-ELECTRICAL SHOCK HAZARD- DO NOT TOUCH TERMINALS- TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION". 8. LISTING AGENCY NAMES AND NUMBERS TO BE INDICATED ON POWER INVERTER AND SOLAR MODULES PER CEC 110.3(b). 9. METALLIC CONDUIT SHALL BE USED WITHIN BUILDING PER CEC 690.31(E). 10. LABEL "DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL" AND " LOADS NOT TO BE ADDED TO THIS PANEL. 11. GEC TO BE INSTALL AS REQUIRED BY MANUFACTURER INSTRUCTIONS AND CEC 690.47 12. PER CEC 690.64 B.2: THE SUM OF THE AMPERE RATINGS OF OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUS BAR SHALL NOT EXCEED 120% THE RATING OF THE BUS BAR OR CONDUCTOR FOR A DWELLING UNIT. 13. THE PV PANELS AND THE INVERTERS REQUIRE NEGATIVE GROUNDING PER MANUFACTURE'S INSTRUCTIONS. 14. ANTI-ISLANDING PROTECTION ENSURES THE SYSTEM WILL NOT EXPORT POWER INTO A BALANCED 60 Hz RESONANT LOAD WHILE THE UTILITY IS DISCONNECTED. 15. PER CEC 690.64(B)(7): UNLESS THE PANELBOARD IS RATED NOT LESS THAN THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT DEVICES SUPPLYING IT, A CONCECTION IN A PANELBOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION. THE BUS OR CONDUCTOR RATING SHALL BE SIZED FOR THE LOADS CONCECTED IN ACCORDANCE WITH ARTICLE 220. A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT WITH THE FOLLOWING OR EQUIVALENT MARKING: "WARNING INVERTER OUTPUT CONCECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE" ELECTRICAL NOTES 1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. 2) ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C WET ENVIRONMENT. 3) WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. 4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. 5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL CECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. 6) WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. 7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. 8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. 9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. 10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH CEC 690. 11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. 12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER CEC 310.15(B)(16). THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) AC OUTPUT CURRENT NOMINAL AC VOLTAGE 240V 13.3A Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9. Location specific temperature obtained from ASHRAE 2017 data tables AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP 2° 31° CONDUIT HEIGHT 0.5" ROOF TOP TEMP 53° CONDUCTOR TEMPERATURE RATE 90° INVERTER SPECIFICATIONS MODEL NOMINAL OUTPUT CURRENT 640VA NOMINAL AC VOLTAGE 2.66A NOMINAL VOLTAGE RANGE 240 VOLTS NOMINAL FREQUENCY POWER FACTOR MAX AC OUTPUT CURRENT 211V/264V 59.3-60.5 HZ MAXIMUM CONTINOUS OUTPUT POWER < 0.99 15.96A DS3-S MICROINVERTER MANUFACTURER AP SYSTEM MODEL HANWHA Structural Only R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TR UONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-7 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° WARNING LABELS A SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS ELECTRICAL SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! LABEL LOCATION: INVERTERS, AC DISCONNECTS, AC COMBINER BOXES, AC JUNCTION BOXES CODE REF: CEC 2022 - 690.13(B) ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED ALL NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED WARNING! ! LABEL LOCATION: AC DISCONNECTS, AC COMBINER BOXES, SERVICE PANELS CODE REF: CEC 2022 - 690.5(C) MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: AMPS VAC PV SYSTEM DISCONNECT 240.0 13.3 LABEL LOCATION: INTERCONNECTION Placard (MSP BACKFEED BREAKER OR TAP BOX IF LINE SIDE TAP), AC DISCONNECTS CODE REF: CEC 2022 - 690.54 PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH LABEL LOCATION: AC DISCONNECTS FOR UTILITY ACCESS CODE REF: UTILITY PHOTOVOLTAIC SYSTEM COMBINER PANEL DO NOT ADD LOADS WARNING! LABEL LOCATION: AC COMBINER BOX CODE REF: CEC 2022 - 690.12(B) WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONCECTION LABEL LOCATION: FIRST BACKFEED BREAKER (MSP/SUBPANEL) IF NO LINE SIDE TAP CODE REF: CEC 2022 - 705.12(B)(2)(3)(b), CEC 2022 - 705.12(B)(3), CEC 2022- 705.12(B)(2)(3)(b), CEC 2022 - 705.12(B)(3) PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED CAUTION! LABEL LOCATION: INTERCONNECTION Placard (MSP BACKFEED BREAKER OR TAP BOX IF LINE SIDE TAP) CODE REF: CEC 2022 - 705.2(4) DO NOT RELOCATE THIS OVERCURRENT DEVICE PV SOLAR BREAKER LABEL LOCATION: FIRST BACKFEED BREAKER (MSP/SUBPANEL) IF NO LINE SIDE TAP CODE REF: CEC 2022 - 705.12(B)(2)(3)(b) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: MSP CODE REF: CEC 2022 - 690.56(C)(3) DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTIC CAUTION! LABEL LOCATION: MSP, UTILITY METER (IF SEPARATE) CODE REF: UTILITY NOTES AND SPECIFICATIONS 1) SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF CEC 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. 2) SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. 3) LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. 4) LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 5) SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4 - 2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. 6) DO NOT COVER EXISTING MANUFACTURER LABELS. Structural Only R E G I S T E RE D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TRUON G 1118 S Hickory St 06/05/23 MSPUMACDACB JB SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-7.1 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 11 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° PV SYSTEM SITE PLACARD PHOTOVOLTAIC SYSTEM SITE PLACARD CAUTION THIS SERVICE SUPPLIED BY ALTERNATIVE POWER SOURCES WITH DISCONNECTS LOCATED AS SHOWN PHOTOVOLTAIC SYSTEM SITE PLACARD CAUTION THIS SERVICE SUPPLIED BY ALTERNATIVE POWER SOURCES WITH DISCONNECTS LOCATED AS SHOWN S H I C K O R Y S T . MAIN SERVICE PANEL UTILITY METER AC DISCONNECT COMBINER PANEL Structural Only R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PH ONG TRU ONG 1118 S Hickory St 06/05/23 SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-8 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° ADDITIONAL NOTES · ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: - 2022 CBC - 2022 CRC - 2022 CEC - 2022 CMC - 2022 CPC - 2022 CFC - 2022 CEC · ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER' S INSTRUCTIONS, CEC 110.2, 110.3, 690.4(B) AND 690.12(5). · ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. · ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. · ALL PV CIRCUITS CONCECTED TO MORE THAN ONE SOURCE SHALL HAVE OVERCURRENT DEVICE LOCATED SO AS TO PROVIDE OVERCURRENT PROTECTION FROM ALL SOURCES, CEC 690.9(A). · ALL EQUIPMENT OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED NEAR THE MAIN ELECTRICAL SERVICE EQUIPMENT, CEC 690.13, 690.15. · RAPID SHUTDOWN EQUIPMENT TO PROVIDE CONTROLLED CONDUCTORS THAT ARE MORE THAN 5 FEET IN LENGTH INSIDE A BUILDING OR MORE THAN 10 FEET FROM A PV ARRAY LIMITATION TO NOT MORE THAN 30 VOLTS AND 240 VOLT-AMPERES WITHIN 30 SECONDS OF RAPID SHUTDOWN INITIATION, CEC 690.12. · THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONCECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, CEC 690.61 & 705.40. · DUE TO THE FACT THAT PV MODULES ARE ENERGIZED WHENEVER EXPOSED TO LIGHT, PV CONTRACTOR SHALL DISABLE THE ARRAY DURING INSTALLATION AND SERVICE BY SHORT CIRCUITING, OPEN CIRCUITING, OR COVERING THE ARRAY WITH OPAQUE COVERING, CEC 690.18. · ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT, CEC310.0(D) AND 690.31(C) THROUGH (G). · ALL CONDUCTORS TO BE MATERIAL APPROVED BY THE CODE AND THEIR INSULATIONS TO BE RATED TO NOT LESS THAN 90°C 600-VOLTS MINIMUM. · INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR GROUNDED DC SYSTEMS, CEC 690.31(B), AND PV-WIRE TYPE FOR UNGROUNDED DC SYSTEM, (AS IN TRANSFORMER LESS INVERTERS OR MICROINVERTERS WITH ISOLATED GROUNDS), CEC 690.35(D). · FINE-STRANDED CABLE CONCECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC 110.14 & 690.74(A). · ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION, CEC 690.31(B). · ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY OR WITH 3-WHITE STRIPES, CEC 200.6, 200.7, & 400.22, AND ALL GROUNDED CONDUCTORS SHALL BE OF BARE WITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C). SOLAR PHOTOVOLTAIC SYSTEM NOTES Structural Only R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TRU ONG 1118 S Hickory St 06/05/23 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 1118 S Hickory St 06/05/23 Expedited Permit Process for PV Systems — Micro-Inverter2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 1118 S Hickory St 06/05/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan 1118 S Hickory St 06/05/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT 1118 S Hickory St 06/05/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram 1118 S Hickory St 06/05/23 1118 S. HICKORY ST. SANTA ANA, CA 92701 MANRIQUEZ, MARIELA Design Criteria 1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16 2 - Wind: 95 MPH, Exposure: C 3 - Wood Species: DF-L No. 1 (SG = 0.5 ) Notice: Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction & solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. 4/24/2023 Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: Job: 1-844-PV ELITE | info@yoursolarplans.com 3000 E. Birch Street Suite 201 | Brea CA 92821 1118 S Hickory St 06/05/23 01201234067389  611 !1"1#$ %33&30''33( !%)''&*+7&+2,(-%'''*./.02 . 02  ,2&7'02 1. '1' 2 -- --3--# #--8 --#3--/ 4 - #--# -- . 5&)226#  789:;<=>?@:A9BC@> DEE:8FFG '''*./.4. 4 ,2&7'41. H@@:EC>9B8FG 33&30''334)''&*+7&+2, IJ8K9BC@>G ,L3 MCA8FB9ANG 2723)70)20 236736'72,7O P9Q9:EMRN8G S D7HITUV W 9XY'7)Z-++[ 9XY2L)Z-&'[ 9XYL7)Z-&&[ 9XY'77)Z-*'[ X/ -!Y *,[ X/ -!YY ,L [ X/ -!YYY '72 [ X/ -!Y\'7+[ D7HITUV ] 9XY'7)Z-&2 [ 9XY2L)Z-&,[ 9XYL7)Z-*L [ 9XY'77)Z-,'[ X/ -!Y '77 [ X/ -!YY ''7 [ X/ -!YYY)Y\''L [ D7HITU]^ . 5&)7LS.--*L [ _`abacdefcghigjkfai`abalmnm_baoeajfkhpcfkfaqbeqjkekrahirahfcfqf`askedacqbkhpiaeghakfgqheghacrkiaidbghtf`audgeightjqiakiqvfgqhvbqjaccw xcabcc`qdeijqhogbrkhp qdfvdfqufkghaiobqrf`gcfqqeygf`f`aeqjkezdf`qbgfp{ksght|dbgcigjfgqhuaoqbavbqjaaightygf`iacgthw }eakcahqfaf`kff`az_~{kkbicup€qjkfgqhyaucgfaygeehqfuadvikfaifqcdvvqbfz~‚ƒ„……w†ghiqdfy`pw ‡CF;J9CA8:  -- -3[ˆ- . 5&----# --!-8- . 5&4  ---  -- #--3- -‰[--4#--# -Š -- #----3-4ˆ-#-- ! !-‹Œ 56 6---#)---!-4-- !--[-ˆ-!#[33-#-----##)-- -! 9-4!!-4-[-4- #-! --Š[-3 # S --3[---#--- -ˆ---4 [--   3 -[- --- -- --- -3-3 #[---Š[ˆ-334   -!--- --3-  ----33[- --Ž![-3[--3- 4ˆ!-Š---/# -!--3- 3 -4-3-3---33- --! !-- 3--ˆ-#--1-3-3[3[ #--[-   !3[-1-3-3#---[ ˆ -!ˆ-! !--- -3 !-ˆ --3- !--- -1 !- -- ‘’ “”•–”—”˜™š™›œžŸ ¡¢£¤œ¢¥ •¦—”§”• ¦¦¦ 1118 S Hickory St 06/05/23 ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes. Roof Slope = 18 ° Roof Shape Hip Tributary Width s = 4.00 ft Tributary Length l = 3.08 ft Effective Area A e = 12.33 ft2 Height of Structure h = 15 ft Wind Speed V = 95 mph Exposure Category C Building Width B = 30 ft Building Length L = 40 ft Zone Width a = 3 ft Elevation Height zg = 95 ft Wind Directionality Kd = 0.85 Topography Factor Kt = 1.00 Ground Elevation Factor Ke = 1.00 Velocity Pressure Exposure Coefficient Kz = 0.85 Velocity Pressure q z = 0.00256KzKztKdKeV2 = 16.61 psf Solar Array Pressure Equalization a = 0.79 Array Edge Factor E = 1.50 Zone GCp p = qz(GCp)( E)( a ) 3 2.59 -50.87 3r - - 3e - - 2 - - 2r 2.37 -46.67 2e 2.59 -50.87 2n - - 1 1.80 -35.42 1'- - 1118 S Hickory St 06/05/23 LAG SCREW ANALYSIS Loads Wind Pressures qz = -50.87 psf Solar Panel Load QD = 3 psf Panel Length l = 6.167 ft Panel Width b 3.425 ft Attachment Spacing s = 4 ft Portrait Tributary Area At = 12.33 ft2 Wind Load PW = qz * At = -627 lbs Dead Load PD = QD * At = 37 lbs Uplift Pa = 0.6 PD + 0.6 Pw = -354 lbs Landscape Tributary Area At = b * s = 6.85 ft2 Wind Load PW = qz * At = -348 lbs Dead Load PD = QD * At = 20.55 lbs Uplift Pa = 0.6 PD + 0.6 Pw = -197 lbs Lag Screw Specific Gravity of Lumber SG = 0.50 (Douglas Fir-Larch) Diameter of Lag Screw D = 5/16 in Withdraw Design /in 1800*SG 3/2 *D 3/4 = 266 lbs/in Depth of Embedment lp = 2.50 in Total Nominal Withdrawal Value W = W * l p = 665 lbs Load Duration Factor CD = 1.6 Withdrawal Design Value W' = W * C D = 1064 lbs Demand Capacity Ratio DCR = Pa / W' = 0.33 < 1 OK 1118 S Hickory St 06/05/23 ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check Roof Slope = 18 ° Roof Shape Hip Tributary Width s = 2.00 ft Tributary Length L = 16.93 ft Effective Area A = L ( MAX [ s , L/3] ) = 96 ft2 Height of Structure h = 15 ft Wind Speed V = 95 mph Exposure Category C Building Width B = 30 ft Building Length L = 40 ft Zone Width a = 3 ft Elevation Height zg = 95 ft Wind Directionality Kd = 0.85 Topography Factor Kt = 1.00 Ground Elevation Factor Ke = 1.00 Velocity Pressure Exposure Coefficient Kz = 0.85 Velocity Pressure q z = 0.00256KzKztKdKeV2 = 16.61 psf Internal Pressure Coefficient (GCpi) = -0.18 Zone GCp p = q z [(GCp) - (Gcpi)] 3 2.06 -37.21 3r - - 3e - - 2 - - 2r 1.35 -25.49 2e 2.06 -37.21 2n - - 1 1.04 -20.34 1' - - 1118 S Hickory St 06/05/23 Beam/ Top Chord Check Lumber: Moment Demand # of Attachment per Rafter NA = Span : Orientation Lenght (ft) : Dead Load Roof Material: QD = psf Live Load QLr = psf Wind Load p = psf Snow Load QS = psf Rafter Spacing s = in Wind Load, Portrait Portrait UL = Wind Load, Landscape Landscape UW = Linear Dead Load wd = plf Live Load wLr = plf Start ft Start ft End ft End ft Snow Load ws = plf Start ft Start ft End ft End ft Ma, Moment D lb-ft D+Lr lb-ft D+S lb-ft 0.6D+0.6W lb-ft D+0.45W+0.75Lr lb-ft D+0.45W+0.75S lb-ft Moment Capacity Framing Member Size Lumber Grade : DF-L No. 1 CM = 1 Ct = 1 Cr= CF = fb = psi C fu =C i = Breadth b = in Depth d = in Section Modulus Sx = bd 2 / 6 = in3 Bending Stress Capacity Fb = CM * C t * Cr * C F * fb = psi Table 4.3.1 NDS 2018 Deflection Limit E = ksi I = in4 Transient Deflection in Transient Deflection Allowed > [OKAY] Total Deflection in Total Deflection Allowed > [OKAY] 1.0 1 20 0.00 24 Comp 0.397 356 180 1.6 2392 psi D+0.45W+0.75S 700 psi 0.29 OKAY 1.6 2392 psi D+0.45W+0.75Lr 700 psi 0.29 OKAY 1.6 2392 psi 0.443 318 120 1700 20.80 0.6D+0.6W 1357 psi 0.57 OKAY 1.15 1719 psi D+S 634 psi 0.37 OKAY OKAY 1.25 1869 psi D+Lr 650 psi 0.35 OKAY DCR 0.9 1346 psi D 634 psi 0.47 7.56 1495 CD Fb' = C D * F b ASD Load Ma / S x 2x6 1.15 1.3 16.93 16.75 16.93 1000 1.50 5.50 399 410 399 855 441 441 0 0.0 0 4.42 0 0 0.0 Portrait 4.42 0.0 Portrait 0 0.0 0.0 AT (ft 2) 12.333 6.85 pd (lbs) 37 -459 pw (lbs) ps (lbs) 0 16.75 40 0.0 0.0 0.0 0.0 0 0.0 Portrait 0 0.0 20.55 -255 0 0 0.0 Portrait 0 0.0 0.0 0 0.0 20 1 2 3 4 Eave 2 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 4.18 11.75 0.00 0.00 1.00 Portrait 3 11.4 37.0 10.00 -37.21 DF-L No. 1 4 j lj (ft) pd,j (lbs) pw,j (lbs) ps,j (lbs) Portrait 1 5.2 37.0 -459 0.0 9.8 37.0 -459 -459 0.0 4 16.0 37.0 -459 0.0 ൌ ሺ െ ሻ െ െ െ ‐1000.0 ‐500.0 0.0 500.0 1000.0 0.000 5.000 10.000 15.000 20.000 1118 S Hickory St 06/05/23 EISMIC WEIGHT COMPARISON / ANALYSIS - (PER CEBC 2022 Part 10 Chapter 5 Section 502.5) PV System Weight Module Model Hanwha Panel Weight Wpanel = 48.5 lbs Number of Panels NPV = 9 Total PV System Weight W PV = Wpanel * NPV = 436.5 lbs Existing Roof Weight Roof Weight QD =10.0 psf Building Length Lbuild =40 ft Building Width W build =30 ft Roof Area Abuild =1200 ft2 Building Perimeter Pbuild = 140 ft Wall Height ht = 8 ft Wall weight Qwall = 15 psf Interior wall weight Qint = 10 psf Roof Load Wfloor = Abuild * QD = 12000 lbs Wall LoadWwall = ht /2 * Qwall * Pbuild + Abuild * Qint /2 = 14400 lbs Total Story Weight Wbuild = Wfloor + Wwall = 26400 lbs Percentage Weight Increase WPV / Wbuild = 1.65%< 10% OKAY 1118 S Hickory St 06/05/23 107.98' 51 . 0 1 ' 51 . 0 1 ' 107.98' 36'-2"9' - 2 " 37'-0" 3' - 6 " MSPUM ACD ACB JB SITE PLAN WITH ROOF PLAN SHEET NAME SHEET SIZE SHEET NUMBER ANSI B PV-1 11" X 17" MYNT SOLAR, INC. (801) 349-6475 Email - Service@myntsolar.com www.myntsolar.com MA R I E L A M A N R I Q U E Z R E S I D E N C E 1 1 1 8 S H I C K O R Y S T . , SA N T A A N A , C A 9 2 7 0 1 , U S A AP N # 0 1 1 0 7 5 2 8 PHOTOVOLTAIC PROJECT INFO UT I L I T Y : S C E PV MODULE: INVERTER: (9) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (5) AP SYSTEM DS3-S MICROINVERTERS(240V) 3.60 kW (DC) / 3.20 kW (AC) ARRAY1 AZIMUTH: 180° CEC 2022 / CRC 2022 / CBC 2022 PROJECT NAME 04-19-2023 REV. BYDATE ARRAY TILT: 18° ARRAY2 AZIMUTH: 270° PHOTOVOLTAIC ROOF MOUNT SYSTEM SITE PLAN & VICINITY MAP 9 MODULES-ROOF MOUNTED - 3.60 kWDC, 3.20 kWAC 1118 S HICKORY ST., SANTA ANA, CA 92701 SYSTEM SUMMARY: ROOF TYPE: - ASPHALT SHINGLE NUMBER OF LAYERS: - 1 ROOF TRUSSES: - 2"X6" @ 24" O.C. STORY: - ONE PROJECT SITE DESIGN CRITERIA: AERIAL VIEW SCALE: NTS VICINITY MAP SCALE: NTS1 SCALE: 1/16" = 1' PV-1 SITE PLAN & VICINITY MAP PV-2 ROOF PLAN WITH MODULES PV-3 STRING LAYOUT PV-4 ATTACHMENT DETAIL PV-5 ELECTRICAL SCHEMATIC PV-6 ELECTRICAL NOTES PV-7 WARNING LABELS PV-7.1 PV SYSTEM SITE PLACARD PV-8 ADDITIONAL NOTES PV-9 APS CHART PV-10+ EQUIPMENT SPEC SHEETS SHEET INDEX (N) 9- HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES (N) 5 - AP SYSTEM DS3-S MICROINVERTERS(240V) (N) JUNCTION BOX 600 V (E) MAIN SERVICE PANEL, 200 FRONT VIEW SCALE: NTS FENCE GOVERNING CODES ● 2022 CALIFORNIA FIRE CODE ● 2022 CALIFORNIA BUILDING CODE ● 2022 CALIFORNIA RESIDENTIAL CODE ● 2022 CALIFORNIA ELECTRICAL CODE ● 2022 CALIFORNIA ADMINISTRATIVE CODE ● 2022 CALIFORNIA ENERGY CODE ● 2022 CALIFORNIA EXISTING BUILDING CODE ● 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE ● 2022 CALIFORNIA HISTORICAL BUILDING CODE ● 2022 CALIFORNIA MECHANICAL CODE ● 2022 CALIFORNIA PLUMBING CODE ● 2022 CALIFORNIA REFERENCED STANDARDS CODE NOTE: (A) PV SYSTEM'S FIRE CLASSIFICATION MUST BE CLASS A ROOFING MATERIAL PER SECTIONS R02.3 OR R904.4 ROOF #1 (08) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES (E ) F R O N T Y A R D AHJ : SANTA ANA (CITY OF), CALIFORNIA UTILITY: SOUTHERN CALIFORNIA EDISON CO GATE PROPERTY LINE PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E S H I C K O R Y S T . ROOF #2 (01) HANWHA Q.PEAK DUO BLK ML-G10+ 400 (400W) MODULES (E) UTILITY METER (N) AC COMBINER BOX (E) MAIN SERVICE PANEL, 200 (N) AC DISCONNECT (E ) B A C K Y A R D (E) DRIVEWAY Structural Only R E G I S T E R E D P R O F E S S I O N A L E N G I N E E R C I V I L No. C70784 Exp. 06/30/2025 S T A T E O F C A L I F O R N IA PHONG TR UONG DocuSign Envelope ID: 59B0FE76-0142-475F-9262-8F68ED9F1D27 awning detached garage The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101114928 Issued 06/14/23 Elec# 20179517 Issued 05/31/23 1118 S Hickory St 06/14/23 1118 S Hickory St 06/05/23