HomeMy WebLinkAbout1313 S Baker St - Plan12 9 10 (N) (19) SOLAREVER SE-166*83-455M-144(455W) MODULES WITH (10) AP SYSTEM DS3-L 2 IN 1 MICRO-INVERTERS ATTACHED TO THE BACK OF MODULES. 1 RO O F T OP GR O U N D LE V E L - HO U S E EX TE R I OR 20A 20A N 2 (N) JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH END OF THE EMT CONDUIT WITH THE WIRE THEN FREE AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL (N) 100A PV LOAD CENTER 12 PV CIRCUIT 1: 9 MODULES/PARALLEL [ (5) AP SYSTEMS DS3-L 2 IN 1] 1 PV CIRCUIT 2: 10 MODULES/PARALLEL [ (5) AP SYSTEMS DS3-L 2 IN 1] 7 8 M POINT OF DELIVERY AND INTERCONNECTION 40A 100A N 3 (E) GROUNDING ELECTRODE OR (UFER) BACKFEED BREAKER (N) VISIBLE LOCKABLE 2 POLE 60A 'KNIFE' AC DISCONNECT 3 AC DISCONNECT TO BE LOCATED WITHIN 10' OF METER EXISTING 240V/125A MAIN SERVICE PANEL SINGLE PHASE (N) MAIN BREAKER DERATED TO 100A 9 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1313 S BAKER ST, SANTA ANA, CA 92707 APN:01303204 DATE:12/14/2022 MURO RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OAC CORE ENERGY GROUP. E-1 Conduit and Conductor Schedule Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size 1 PV WIRES 10 AWG 2 N/A - Free Air N/A - Free Air 1 Bare Copper Ground (EGC/GEC) 6 AWG 1 N/A - Free Air N/A - Free Air 2 THWN-2 10 AWG 4 EMT 3/4" 2 THWN-2 - Ground 8 AWG 1 EMT 3/4" 3 THWN-2 8 AWG 3 EMT 3/4" 3 THWN-2 - Ground 8 AWG 1 EMT 3/4" METER # 222013457962 Inverter Ratings Inverter Make/Model AP SYSTEM DS3-L Max DC Volt Rating 60V Max Continuous Output Power 768W Max Nominal Voltage 240V Max AC Current 3.20A Max OCPD Rating 20A DESIGN TEMPERATURES ASHRAE EXTREME LOW -2°C ASHRAE 2% HIGH 39°C PV Module Ratings @ STC Module Make/Model SOLAREVER SE-166*83-455M-144(455W) MODULE Max Power-Point Current (Imp)10.96A Max Power-Point Voltage (Vmp)41.51 V Open-Circuit Voltage (Voc)49.35V Short-Circuit Current (Isc)11.41 A Max Series Fuse (OCPD)20A Nominal Maximum Power at STC (Pmax)455W Maximum System Voltage 1500V Voc Temperature Coefficient -0.29%/°C SYSTEM SUMMARY BRANCH #1 INVERTERS PER BRANCH 5 MAX AC CURRENT 16A MAX AC OUTPUT POWER 3840W ARRAY STC POWER 8645W ARRAY PTC POWER 8069.3W MAX AC CURRENT 32.00A MAX AC POWER DERATED (CEC) AC POWER 7786.87W BRANCH #2 5 16A 3840W 7680W MAIN SERVICE PANEL 240/120V 1Ø, 3W MAIN BUSS: 125A MAX BREAKER SIZE: (125A X 1.2) - 100A = 50.0A 1313 S Baker St 03/24/23 N 1. NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE 3. ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. 4. DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. PERMANENT SIGNAGE NOTES: WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(b) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2019: 705.12(B)(2)(3)(c), SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2019: 690.13(B) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION 5$3,' 6+87'2:1 6: ,7&+ )25 62/$5 39 6<67(0 LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2019: 690.56(C)(3), CFC 2019: 1204.5.3 32:(5727+,6%8,/',1*,6 $/626833/,(')5207+( )2//2:,1*6285&(6:,7+ ',6&211(&76$66+2:1 &$8 7,21 (N) SOLAR PANELS AND MICRO-INVERTERS ON ROOF MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 32.00 AMPS 240.0 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2019: 690.54 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1313 S BAKER ST, SANTA ANA, CA 92707 APN:01303204 DATE:12/14/2022 MURO RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OAC CORE ENERGY GROUP. E-2 1 3 1 3 S BA K E R S T WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. PV INTERCONNECTION POINT LOCATION OF METER MAIN COMBO, AC DISCONNECT & PV LOAD CENTER. 1313 S Baker St 03/24/23 3' 1'-6" 3' N 1'-6" 3' SCALE: 3/32" = 1'-0" PV SYSTEM SITE PLAN PV SYSTEM SIZE: 8.645 kW DC LEGEND M METER MAIN COMBO CONSTRUCTION NOTES NEW SOLAR PANELS DRIVEWAY 1313 S BAKER ST ROOF OBSTRUCTIONS SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1313 S BAKER ST, SANTA ANA, CA 92707 APN:01303204 DATE:12/14/2022 MURO RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OAC CORE ENERGY GROUP. PV-1 (E) SWIMMING POOL 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC WIND SPEED OF 110 MPH (3 SECOND GUST), WIND EXPOSURE C. 3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ON CENTER. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 11" OF NAILING PLATES. 4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (CRC R324.7.1, CBC 3111.2.1) 6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. 6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREES, WIRES, OR SIGNS. 7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES IN COMPLIANCE WITH 2019 CFC/2018 IFC 1204.2.1.2 TOTAL PLAN VIEW AREA = 2744.9 SQFT TOTAL PV AREA = 19(82.44 IN)(40.86 IN)/(144 IN^2) = 444.45 SQFT (444.45 SQFT/ 2744.9 SQFT)100 = 16.19% TOTAL PV AREA POPULATES 16.19% OF TOTAL PLAN VIEW AREA AND IS WITHIN THE 33% REQUIREMENT. PV LOAD CENTERLC PV INTERCONNECTION POINT. LOCATION OF METER MAIN COMBO, AC DISCONNECT & PV LOAD CENTER MOUNTED ON EXTERIOR WALL OF A SINGLE FAMILY RESIDENCE. M LC LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 CAL-FIRE ROOF LADDER ACCESS POINT CAL-FIRE ROOF LADDER ACCESS POINT (19) SOLAREVER SE-166*83-455M-144(455W) WITH (10) AP SYSTEM DS3-L MICRO-INVERTERS MOUNTED TO THE BACK OF MODULES MOUNTED ON COMP SHINGLE & ROLLED SHINGLE ROOF Roof Azimuth: 90° Roof Tilt: 5° Roof Section 1 PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E PR O P E R T Y L I N E ACD AC DISCONNECT ACD (E) SERVICE DROP Roof Azimuth: 180 ° Roof Ti lt: 21 ° Roof Section 2 Signed: 12/02/22 Bldg# 101114359 Elec# 20179109 Issued 03/24/23 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 1313 S Baker St 03/24/23 6' 6' 6' 6' 6' 6' N N SCALE: 1/8" = 1'-0" PV SYSTEM MOUNTING DETAILS EXISTING ROLLED SHINGLE ROOF QUICK MOUNT PV QMLSH FOR ROLLED SHINGLE @ 72" O.C. MAX PROPOSED EVEREST CROSSRAIL RACKING PROPOSED SOLAREVER SE-166*83-455M-144(455W) PV SOLAR MODULES EXISTING 2 "X 4" ROOF TRUSSES @ 24"O.C. SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1313 S BAKER ST, SANTA ANA, CA 92707 APN:01303204 DATE:12/14/2022 MURO RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OAC CORE ENERGY GROUP. PV-2 Roof Azimuth: 180° Roof Tilt: 21 ° Roof Section 2 Roof Azimuth: 90° Roof Tilt: 5° Roof Section 1 EVEREST SPLICE FOOT XL FOR COMP SHINGLE @ 72" O.C. MAX EXISTING COMP SHINGLE ROOF Signed: 12/02/22 1313 S Baker St 03/24/23 910 10 6 21 7 9 21 7 26 S-5 D5 20 15 18 2212 14 13 S-5 D4 26 1 2 5 4 8 3 25 24 23 ''(7$ ,/  75$169(56( 127 72 6&$/( ''(7$ ,/  /21*,78',1$/ 127 72 6&$/( '5$&. ,1* '(7$ ,/  75$169(56( 127 72 6&$/( '5$&. ,1* '(7$ ,/  723 127 72 6&$/( '5$&. ,1* '(7$ ,/  /21*,78',1$/ 127 72 6&$/( SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1313 S BAKER ST, SANTA ANA, CA 92707 APN:01303204 DATE:12/14/2022 MURO RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OAC CORE ENERGY GROUP. 1. ROOF MATERIAL: ROLLED SHINGLE 2. ROOF STRUCTURE: TRUSSES 3. ATTACHMENT TYPE: QUICK MOUNT PV QMLSH 4. MODULE MANUFACTURER: SOLAREVER 5. MODULE MODEL: SE-166*83-455M-144(455W) 6. MODULE LENGTH: 82.44'' 7. MODULE WIDTH: 40.86" 8. MODULE WEIGHT: 51.8 LBS. 9. SEE SHEET S-1 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 18" 11. TRUSSES SPACING: 24" O.C. 12. TRUSSES SIZE: 2 "X 4" NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 2.5 IN. 15. TOTAL # OF ATTACHMENTS: 16 16. TOTAL AREA: 233.92 SQ. FT. 17. TOTAL WEIGHT: 518.00 LBS. 18. WEIGHT PER ATTACHMENT: 32.37 LBS. 19. DISTRIBUTED LOAD: 2.21 PSF 20. MAX. HORIZONTAL STANDOFF: 72IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 39 IN. 22. STANDOFF STAGGERING: YES 23. RAIL MANUFACTURER AND MODEL (OR EQUIV.):EVEREST CROSSRAIL 24. RAIL WEIGHT: 0.436 PLF. 25. MAX. TRUSSES SPAN: 12 FT. 26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. PV-3 Signed: 12/02/22 1313 S Baker St 03/24/23 1313 S Baker St 03/24/23 1313 S Baker St 03/24/23 1313 S Baker St 03/24/23 1313 S Baker St 03/24/23 1313 S Baker St 03/24/23 1313 S Baker St 03/24/23 1313 S Baker St 03/24/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1053344 Solgen Construction, LLC Cole Farmer Permits@CoreEnergyGroup.com 559-462-6009 1313 S Baker St, Santa Ana, CA 92707 3/20/2023 1313 S Baker St 03/24/23 To Whom It May Concern, This letter serves to confirm I have chosen to have my system installed by Solgen Construction LLC. You have my express permission to cancel any other solar permits associated with my property and move forward with the solar permit applied for by Solgen Construction LLC for my property at 1313 S Baker St, Santa Ana, CA 92707 Thank you, Raymond Muro DocuSign Envelope ID: 48A42958-9A50-4DAB-9F73-D58702E35ECE 12/21/2022 1313 S Baker St 03/24/23 DocuSign Envelope ID: 48A42958-9A50-4DAB-9F73-D58702E35ECE 1313 S Baker St 03/24/23 220.12 1,978 ft²5,934 va ft²0 va 220.52(A) 7 x 1500va = 10,500 va 220.52(B) 1 x 1500va = 1,500 va 17,934 va 220.42 3,000 va 5,227 va va 8,227 va 220.54 Qty 0 0 kW w Qty 0 0 kW w 0 w 220.55 Qty kW Qty kW Qty kW 0 w 220.51 0 kW AC#1 / Geo 16 SEER 2 Ton 2.5 Kva 0 kW AC#2 / Geo SEER Ton Kva 0 kW AC#3 / Geo SEER Ton Kva 0 kW AC#4 / Geo SEER Ton Kva 0 kW AC#5 / Geo SEER Ton Kva 2,487 va 220.14 Qty va(watts)Qty va(watts) 1 1,200 1 1,580 2,780 va 220.53 2,085 va 220.5 Qty va(watts) Total Qty va(watts) Total 1 375 375 0 0 0 1 750 750 0 0 0 0 0 0 0 0 0 0 0 0 0 1,125 va 430.24 188 va 1,313 va 14,112 va 59 Amps 125 AMPS 50 Available solar 100 AMPS 100 Amps General Lighting Load: Customer Name: Site Address: Basement Floor Area = 3 va/ft² of floor area, including unused space adaptable for future use. Raymond Muro 1313 S Baker St, Santa Ana, CA 92707 Dwelling Unit Electrical Service Load Calculator Fixed Electric Space Heating Loads or Air Conditioning Load: Electric Clothes Dryers: Floor Area = Total General Lighting & Applicance Load = # of Small Appliance Branch Circuits = # of Laundry Branch Circuits = 1500va for each 20 amp branch circuit required per 210.1(C)(1) in EACH kitchen, pantry, breakfast room, dining room or similar areas. Small Appliance Load: Laundry Load: Lighting Load Feeder Demand Factors: Remainder over 120,000 at 25% From 3,001 to 120,000 at 35% First 3,000 or less at 100% Electric Dryer #1 Electric Dryer #2 Total Lighting Demand Load = Electric Cooking-Ranges, Stove Tops and Wall Ovens: Total Heat & Air Conditioning Load = Total Electric Cooking Demand Load = Total Electric Clothes Dryers Load = Appliance Load - Dwelling Units Dishwasher Microwave Description Description Total Connected Appliance Load = Total Appliance Demand Load =Appliance Load - Dwelling Units Motor Loads @ 120 Volts Description Description .5 HP Garbage Disposal Several Motors or a Motor(s) & Other Load(s) Service Size Requested = Fixed Electric Space Heat #1 Fixed Electric Space Heat #2 Fixed Electric Space Heat #3 Fixed Electric Space Heat #4 Fixed Electric Space Heat #5 Total Calculated Demand Load in AMPS @ 120/240V 1ph3W = Existing Service Size Minimum Service Size 25% of Largest Motor Load = Total Motor Load = Total Motor Demand Load = Total Calculated Demand Load in Volt-ampers = 1 HP Pool/Spa Pump 1313 S Baker St 03/24/23 76 North Meadowbrook Drive Scott E. Wyssling, PE Alpine, UT 84004 Cole D. Larsen, SE, PE office (201) 874-3483 Gregory T. Elvestad, PE swyssling@wysslingconsulting.com December 2, 2022 Green World Renewable Energy 4408 Ritchie Highway Baltimore, MD 21225 Re: Engineering Services Muro Residence 1313 South Baker Street, Santa Ana, CA 8.645 kW System To Whom It May Concern: We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A.Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B.Description of Structure: Roof Framing: Assumed 2x6 dimensional lumber at 24” on center. Roof Material: Rolled Shingles Roof Slopes: 5 degrees Attic Access: Inaccessible Foundation: Permanent C. Loading Criteria Used • Dead Load o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load = 20 psf (reducible) – 0 psf at locations of solar panels • Ground Snow Load = 0 psf • Wind Load based on ASCE 7-16 o Ultimate Wind Speed = 110 mph (based on Risk Category II) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2019 California Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing will support the additional panel loading without damage, if installed correctly. 1313 S Baker St 03/24/23 Page 2 of 2 D.Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent Everest Solar Systems installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The maximum allowable withdrawal force for a M5 x 60mm lag screw is 213 lbs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2”, the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using two (2) M5 x 60mm lag screw with a minimum of 2” embedment will be adequate and will include a sufficient factor of safety. 3. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 72” on center. 4. Panel supports connections shall be staggered to distribute load to adjacent framing members. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2019 CRC, current industry standards and practice, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Very truly yours, Scott E. Wyssling, PE California License No. 83664 Signed: 12/02/22 1313 S Baker St 03/24/23 Wyssling Consulting 76 N. Meadowbrook Drive Alpine, UT 84004 (201) 874-3483 swyssling@wysslingconsulting.com Existing Muro Residence Roof Dead Load 1313 South Baker Street 2 psf Rolled Asphalt Santa Ana, CA 1 psf 7/16" Plywood Sheathing 1 psf 2x6 @ 24 in. o.c. 0 psf Ceiling, Mechanical, Electrical 2 psf Miscellaneous 7 psf TOTAL Second Floor Dead Load 0 psf Floor Finishes 0 psf 1 1/8" Subfloor Sheathing 0 psf Joists @ 16' o.c. 0 psf Partitions 0 psf Ceiling, Mechanical, Electrical 0 psf Miscellaneous 0 psf TOTAL Roof Live Load Floor Live Load 20 psf 0 psf Roof Snow Load Ground SnowLoad= 0 psf (to be divided by cosine of roof angle for horizontal projection ASCE 7 Sec. 7.4) pf = 0.7 Ce Ct I pg = 0 psf Ce = 1, Ct = 1.1 Flat Roof Snow Load (ASCE 7-16 Eq. 7.3-1) Cs = 1.00 ASCE 7-16 Figure 7.4-1 Additional Roof Dead Load - New Solar Panels 3 psf Roof Live Load at Solar Panels 0 psf Roof Snow Load at Solar Panels 0 psf Sloped Roof Snow Load (ASCE 7-16 Eq. 7.4-1) Total Total Existing Roof Load = (DLROOF + Max(LLROOF or S)) AreaROOF 73235 lbs Total New Roof Load = (DLROOF + DLADD + Max(LLROOF or S)) AreaROOF 65463 lbs Change in Demand = (Total New Roof Load - Existing Roof Load) / Existing Roof Load -10.61% 2018 IEBC Section 807.4 states: "Existing structural elements supporting any additional gravity loads as a result of the alterations, including the effects of snow drift , shall comply with the International Building Code. EXCEPTION: 1. Structural elements whose stress is not increased by more than 5%." Gravity Loads Total New Gravity Loads are less than Existing Loads. OK 12/2/2022 1313 S Baker St 03/24/23 Wyssling Consulting 76 N. Meadowbrook Drive Alpine, UT 84004 (201) 874-3483 swyssling@wysslingconsulting.com V = 95 Basic Wind Speed Muro Residence Exposure C ASCE 7-16, Section 26.7 1313 South Baker Street Kz = 0.85 Velocity Pressure Coefficient, ASCE 7-16, Figure 26.10-1 Santa Ana, CA Kzt = 1 Topographic Factor, ASCE 7-16, Section 26.8.2 Kd = 0.85 Directionality Factor, ASCE 7-16, Section 26.6 Ke = 0.970 Ground Elevation Factor, ASCE 7-16, Section 26.9 qh = 16.2 psf qh = 0.00256KzKztKdKeV2 (ASCE 7-16 Eq. 26.10-1) Roof Angle = 5 deg Roof Type Gable sanchor = 72 in Horizontal spacing of roof anchors Atrib = 20.61 sf Panel Area tributary to each roof anchor GCp External Pressure Coefficient, ASCE 7-16, Figure 30.3-2 Roof Zone Zone 1 1' Zone 2 Zone 3 -1.68 -0.90 -2.28 -3.16 ga = 0.75 Pressure Equalization Factor, ASCE 7-16 Figure 29.4.-8 gE = 1.00 Edge Array Factor, ASCE 29.4.3 edges < 0.5*building height, and panel spacing < 4ft. pnet = qhGCpgEga =Design Wind Pressure, ASCE 7-16, Equation 29.4-7 Roof Zone 1 1' Zone 2 Zone 3 -21 psf -11 psf -28 psf -39 psf Min Pressure = -16 psf Use 21 psf Use 16 psf Use 28 psf Use 39 psf ULTIMATE x 0.6 = 16 psf 16 psf 17 psf 23 psf ALLOWABLE Connection to Existing Roof Framing F.S. = 1 Additional Factor of Safety applied to withdrawl force, if desired Atrib = 20.6 ft2 DLpanel = 3 psf Roof Zone 1 1' Zone 2 Zone 3 Wuplift = 21 psf 16 psf 28 psf 39 psf Plag = F.S. x Atrib x (0.6D - 0.6W) =Withdrawl force for each roof anchor Roof Zone 1 1' Zone 2 Zone 3 -222.9 lbs -166.8 lbs -312.7 lbs -445.4 lbs Connection Capacity db = 1/5 in Lag Screw diameter Dpen = 2 in Lag Screw penetration into existing framing member No. of Screws 2 Screws per Connection Species of wood framing C D = 1.6 Load Duration Factor for Wind Loading, NDS Table 2.3.2 Ct = 0.7 Temperature Factor, NDS Table 10.3.4 W = 190 lb/in Withdrawl Capacity, NDS Equation 11.2-1 W' = C D x Ct x W = 213 lb/in Adjusted withdrawl value Pallow = Dpen x W' = 853 lbs (Using (2) screws per connection) Roof Zone 1 1' Zone 2 Zone 3 DEMAND = 223 lbs 167 lbs 313 lbs 445 lbs CAPACITY = 853 lbs 853 lbs 853 lbs 853 lbs up to72in ok up to72in okup to72in ok up to72in ok Douglas Fir-Larch Wind Uplift Rooftop Solar Panels Parallel to Roof Surface ASCE 7-16, Section 29.4.4 This analysis calculates the capacity of the lag screws only. For capacity of the complete mounting system, please see manufacturer's recommendations. 12/2/2022 1313 S Baker St 03/24/23 SHEET # T-1 T-2 PV-1 PV-2 PV-3 PV-4 E-1 E-2 S-1 S-2 S-3 S-4 S-5 S-6 SHEET NAME COVER SHEET PLAN NOTES SITE PLAN LAYOUT ATTACHMENT DETAILS MOUNTING DETAILS MOUNTING DETAILS ELECTRICAL DIAGRAM WARNING LABELS SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET PROJECT INFORMATION PROPERTY OWNER NAME:RAYMOND MURO PHONE:- CONTRACTOR NAME:SOLGEN CONSTRUCTION PHONE:(559)442-9887 DESIGN SPECIFICATIONS OCCUPANCY: R-3 CONSTRUCTION TYPE: SINGLE FAMILY RESIDENCE ZONING: RESIDENTIAL GROUND SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH APPLICABLE CODES & STANDARDS 2019 CALIFORNIA RESIDENTIAL CODE (CRC) 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA MECHANICAL CODE (CMC) 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA PLUMBING CODE (CPC) 2019 CALIFORNIA ENERGY CODE (ENERGY) 2019 CALIFORNIA GREEN BUILDING CODE (CALGREEN) 2017 NATIONAL ELECTRICAL CODE (NEC) 2019 CALIFORNIA FIRE CODE (CFC) COORDINATES: 33.730245, -117.882694 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1313 S BAKER ST, SANTA ANA, CA 92707 APN:01303204 DATE:12/14/2022 MURO RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OAC CORE ENERGY GROUP. T-1 AERIAL VIEW TYPE OF INTERCONNECTION: BACKFEED BREAKER IN THE MSP SCOPE OF WORK SYSTEM SIZE: STC: 19 X 455W = 8.645kW PTC: 19 X 424.7W = 8.069kW (19)SOLAREVER SE-166*83-455M-144(455W) MODULES (10)AP SYSTEM DS3-L MICROINVERTERS (1)100A PV LOAD CENTER (1)60A KNIFE AC DISCONNECT MSP UPGRADE: NO MAIN BREAKER DERATE: YES, TO 100A RACKING & MOUNTING PV ATTACHMENT TYPE: EVEREST SPLICE FOOT XL FOR COMP SHINGLE & QUICK MOUNT PV QMLSH WITH CHEM LINK FOR ROLLED SHINGLE ROOF RACKING TYPE: EVEREST CROSSRAIL- ROOF MOUNT RACKING HARDWARE MURO RESIDENCE NEW PHOTOVOLTAIC SYSTEM PROJECT - 8.645 kW DC / 7.680 kW AC Signed: 12/02/22Signed: 12/02/22 1313 S Baker St 03/24/23 1.1. PROJECT NOTES: 1.2. THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.4. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.5(A) 1.5. ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4 & NEC 690.60: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.6. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 1.7. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. 1.8. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 1.9. SCOPE OF WORK: 1.10. PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.11. WORK INCLUDES: 1.12. PV ROOF ATTACHMENTS - EVEREST SPLICE FOOT XL FOR COMP SHINGLE & QUICK MOUNT PV QMLSH WITH CHEM LINK FOR ROLLED SHINGLE ROOF 1.13. PV RACKING SYSTEM INSTALLATION - EVEREST CROSSRAIL ROOF MOUNT RACKING HARDWARE 1.14. PV MODULE AND INVERTER INSTALLATION - SOLAREVER SE-166*83-455M-144(455W) MODULES / AP SYSTEM DS3-L MICROINVERTERS 1.15. PV EQUIPMENT GROUNDING 1.16. PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.17. PV LOAD CENTERS (IF INCLUDED) 1.18. PV METERING/MONITORING (IF INCLUDED) 1.19. PV DISCONNECTS 1.20. PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.21. PV FINAL COMMISSIONING 1.22. (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.23. SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE 1.24. SITE NOTES: 1.25. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 1.26. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 1.27. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 1.28. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 1.29. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 1.30. EQUIPMENT LOCATIONS: 1.31. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 1.32. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C) 1.33. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 1.34. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 1.35. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 1.36. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 1.37. STRUCTURAL NOTES: 1.38. RACKING SYSTEM 1.39. PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND 1.40. A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 1.41. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED SEALED PER LOCAL REQUIREMENTS. 1.42. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 1.43. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 1.44. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 1.45. WIRING & CONDUIT NOTES: 1.46. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 1.47. CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 1.48. VOLTAGE DROP LIMITED TO 1.5%. 1.49. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 1.50. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15 1.51. GROUNDING NOTES: 1.52. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 1.53. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 1.54. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136(A). 1.55. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICROINVERTER MANUFACTURERS’ INSTRUCTIONS. 1.56. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 1.57. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 1.58. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119] 1.59. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 1.60. GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.5 IN GENERAL AND NEC 690.5 (A)(1) SPECIFICALLY. 1.61. DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.62. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 1.63. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 1.64. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [NEC 690.12]. LOCATION OF LABEL ACCORDING TO AHJ 1.65. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 1.66. MICROINVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). 1.67. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. 1.68. INTERCONNECTION NOTES: 1.69. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 690.64 (B)] 1.70. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120% OF BUSBAR RATING [NEC 705.12(D)(2)(3)]. 1.71. WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, PV DEDICATED BACKFFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(D)(2)(3)]. 1.72. AT MULTIPLE PV OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (D)(2)(3)(C). 1.73. FEEDER TAP INTERCONNECTION (LOAD SIDE) ACCORDING TO NEC 705.12 (D)(2)(1) 1.74. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.12 (A) WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 1.75. BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC 705.12 (D)(5)]. SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 1313 S BAKER ST, SANTA ANA, CA 92707 APN:01303204 DATE:12/14/2022 MURO RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OAC CORE ENERGY GROUP. T-2 Signed: 12/02/22 1313 S Baker St 03/24/23