HomeMy WebLinkAbout1402 W 10th St & Unit #2 - 101117923-24 - Plan2% G G 2% 2% 2% 2% 2% 5% 5% 2% 2% 2% 2% 2%2% 5% 2%2% 2%2%2% 2% 2% G 2% 2% 2% 2% 2% 5% 5% 2% 2% 2% 2%2% 5% 5% 2% JURISDICTION HAVING AUTHORITY: CITY OF SANTA ANA, CA 92703 LEGAL DESCRIPTION: TRACK 1262, LOT 18 ASSESSORS PARCEL NO. APN: 004-122-25 IN FLOOD ZONE FEMA SHFA'S: FLOOD ZONE X CONSTRUCTION TYPE: V-B ZONING: R1 RESIDENTIAL OCCUPANCY GROUP: R3/U SPRINKLERS: MAIN UNIT = NO; ADU = NO NUMBER OF STORIES: MAIN UNIT = 1; ADU = 1 BUILDING MAX HEIGHT: 15'-9 1/2" (ALLOWABLE: 20 FT) REQUIRED SETBACKS: TO (E) MAIN HOUSE: 15 FT (BE REDUCED FOR ADU 800SF) TO (E) GARAGE 5 FT REAR & SIDE: 4 FT SETBACKS INDICATE REQUIRED MINIMUM DISTANCE FROM PROPERTY LINES. CONTRACTOR TO VERIFY ON SITE. LOT SIZE : 6,219 SF (0.15 ACRES) EXISTING: (E) MAIN HOUSE LIVING AREA 1,290 SF (E) ENTRY PORCH 143 SF (E) STORAGE TO BE LEGALIZED 74 SF (E) GARAGE AREA 360 SF EXISTING TOTAL: 1,867 SF NEW CONSTRUCTION: (N) DETACHED ADU AREA 800 SF (N) ENTRY PORCH 60 SF NEW TOTAL:860 SF MAXIMUM LOT COVERAGE: 35% OVERALL LOT COVERAGE: 1,867 SF + 860 SF = 2,727 SF 2,727 SF / 6,219 SF = 43,8% LOT COVERAGE AND USE INTENSITY MAXIMUM ESTABLISHED IN ZONING DISTRICT MAY BE EXCEEDED TO PERMIT AN ADU UP TO 800SF IN SIZE. OPEN SPACE REQUIREMENTS:1,200 SF PROVIDED:1,807 SF (BE REDUCED FOR ADU 800SF) ADU/SFR SQUARE FOOTAGE RATIO: 800 SF/ 1290 SF = 0.62 DRAINAGE DIRECTION AND SLOPE PROPERTY LINE CORNER POINTS AND ELEVATION DATUM #KEYNOTE CALLOUTS EXISTING TO BE REMAINED AND NEW CONSTRUCTION EXISTING TO BE DEMOLISHED FIRE SEPARATION DISTANCEF.S.D FIRE SEPARATION LINE (IMAGINARY PROPERTY LINE)F.S.L 1. DEMOLITION CONTRACTOR SHALL RELOCATE REUSABLE MATERIALS TO DESIGNATED SALVAGE AREA, NON-USABLE MATERIALS SHALL BE PLACED APPROPRIATELY IN REFUSE BIN AND SHALL BE COVERED AT NIGHT AND DURING RELATIVE HIGH WINDS, RAIN, ETC...REFUSE BIN SHALL BE COVERED DURING TRANSFER TO AND FROM DUMP SITE. CONTRACTOR TO BE LIABLE FOR REFUSE SPILLING. ALL DEBRIS TO BE HAULED AWAY AND CLEAN-UP SHALL BE COMPLETED TO BROOM FINISH. EXISTING MATERIALS AND/OR STRUCTURE TO REMAIN SHALL BE PROTECTED FROM DUST, PAINT CHIPPING, ETC..., BY USE OF PLASTIC OR WHATEVER IS REQUIRED FOR PROPER PROTECTION. EXISTING STRUCTURES SHALL HAVE BRACING AND SHORING AS REQUIRED TO PROTECT THE EXISTING STRUCTURE. PROVIDE DE- WATERING FACILITIES FOR CONSTRUCTION AS REQUIRED. COORDINATE AS- BUILT INFORMATION, STRUCTURAL, ETC. TO DESIGNER/ENGINEER AS REQUIRED. 2. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOID WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. 3. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOTCLEAR AND UNOBSTRUCTED ACCESS TO ANY WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULLBOXES,TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, PPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET OF ANY POWER LINES WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES. 4. WHEN UTILITIES METER ALTERATION / RELOCATION OCCUR, INSTALLATION PROCEDURES SHALL BE VERIFIED AND APPROVED BY THE BUILDING INSPECTOR PRIOR TO INSTALLATION. 5. THE APPLICANT/PROPERTY OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING UTILITY EASEMENTS AND/OR CLEARANCES ON- SITE THAT MAY AFFECT THE PROJECT. 6. THE ADU SF / SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN ----- OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVE ---- 7.ALL CONCEALED WORK INSTALLED WITHOUT PERMITS MUST BE EXPOSED FOR INSPECTION TO THE SATISFACTION OF THE BUILDING INSPECTOR. THIS INCLUDES METHODS OF ATTACHMENT AND ALL FOOTINGS, STRUCTURAL MEMBERS, MECHANICAL, ELECTRICAL, PLUMBING AND INSULATION. 8. MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT PART OF THIS PLAN REVIEW AND APPROVAL. MEP ARE SUBJECT TO BUILDING FIELD INSPECTION. PARKING REQUIREMENT NOTWITHSTANDING ANY OTHER LAW, A LOCAL AGENCY, WHETHER OR NOT IT HAS ADOPTED AN ORDINANCE GOVERNING ACCESSORY DWELLING UNITS IN ACCORDANCE WITH SUBDIVISION, SHALL NOT IMPOSE PARKING STANDARDS FOR AN ACCESSORY DWELLING UNIT IN ANY OF THE FOLLOWING INSTANCES: THE ACCESSORY DWELLING UNIT IS LOCATED WITHIN ONE-HALF MILE WALKING DISTANCE OF PUBLIC TRANSIT. TOTAL PARKING REQUIRED (E) MAIN HOUSE: 2 STALLS (N) ADU 0 STALL (SEE EXCEPTION ABV.) TOTAL: 2 STALLS PROJECT LOCATION 0.2 MILES TO PUBLIC TRANSITION 1. PROVIDE LOW CONSUMPTION WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. 2. PROVIDE 72" HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE. 3. FINAL APPROVAL REQUIRED BY THE PUBLIC WORKS DEPARTMENT FOR STREET IMPROVEMENTS, CURB CORES, CURB/GUTTERS, ETC. SEPARATE PUBLIC WORKS PERMIT REQUIRED FOR DRIVEWAYS, APPROACH TO DRIVEWAY, SEWER LATERALS AND ANY WORK IN RIGHT OF WAY. 4. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND AMENDMENTS. 5. A SURVEY SHALL BE PROVIDED BY A LICENSED SURVEYOR ON STRUCTURES WHICH DEFINE PROPERTY LINES, SET BACKS, DESIGNATED PARKLAND OR STREET RIGHT-OF-WAY. 6. WATER HEATER MUST BE STRAPPED TO WALL. 7. PROVIDE RAIN GUTTERS AND CONVEY RAIN WATER TO THE STREET. 8. CONTRACTOR AND/OR OWNER SHALL VERIFY CONSTRUCTION SITE TO CONFIRM THAT THERE IS NO TRACEOF DEMOLISHED SWIMMING POOL WITHIN 5 FT FROM PROPOSED PERIMETER OF THE CONSTRUCTION SITE. OTHERWISE, THEY NEED TO SUBMIT SOIL COMPACTION REPORT FROM LICENSED SOIL ENGINEER TO BUILDING INSPECTOR PRIOR TO FOUNDATION INSPECTION. 9. SHEARWALLS, LATHING & PLASTER IN MATERIALS SHALL CONFORM TO THE STANDARD LISTED IN CH.6 & CH.7 CRC 10. UFER GROUND IS REQUIRED AT NEW ELECTRICAL SERVICE. 11. UNDERGROUND UTILITIES REQUIRED ON SITE PLAN AND SHOW FOR ELECTRICAL, CABLE TV. AND TELEPHONE. 12. ARC FAULT CIRCUIT INTERRUPTION PROTECTION IS REQUIRED FOR ALL BRANCH CIRCUITS PER 2022 CRC210.12 SHALL BE AFCI PROTECTED. 13. BATHROOMS, KITCHEN, GARAGE & OUTSIDE OUTLETS WILL BE GFCI PROTECTED RECEPTACLE OUTLETS. 14. PROVIDE MECHANICAL VENTILATION FOR BATHROOMS AND LAUNDRY ROOMS WITHOUT OPENABLE WINDOW. 15. GLAZING WHICH IS LESS THAN 60 INCHES FROM A FLOOR AND WITHIN A 24" ARC OF A DOORWAY'S VERTICAL EDGE MUST COMPLY WITH CH.3 CRC 16. LANDINGS AT DOOR. LANDINGS SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE STAIRWAY OR THE DOOR, WHICHEVER IS GREATER. 17. EVERY SPACE INTENDED FOR HUMAN OCCUPANCY SHALL BE PROVIDED WITH A NATURAL LIGHT IN ACCORDANCE WITH SECTION R303.1 OR SHALL BE PROVIDE AN AVERAGE ILLUMINATION OF 6 FEET-CANDLES OVER THE AREA OF THE ROOM AT A HEIGHT OF 30" ABOVE THE FLOOR LEVEL. 18. THE CONTRACTOR SHALL EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS, SURVEY THE PROPERTY AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND SCOPE OF WORK. ALL COST SUBMITTED SHALL BE BASED ON A THROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. ANY DISCREPANCY AND/OR UNCERTAINTY AS TO WHAT MATERIALS OR PRODUCT IS TO BE USED SHOULD BE VERIFIED WITH THE OWNER OR ENGINEER OF RECORD. 19. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALE. 20. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND THE DESIGNER/ENGINEERS SHALL BE NOTIFIED, IN WRITING, IMMEDIATELY. 21. VERIFY WITH AQMD FOR ASBESTOS REMOVAL PROCEDURE AND SUBMIT ASBESTOS REPORT TO BUILDING DIVISION PRIOR TO DEMOLITION PERMIT ISSUANCE. 22. WHEN SOLAR PANEL IS REQUIRED, SOLAR PLANS SHALL BE REVIEWED AND APPROVED BY BUILDING DIVISION PRIOR TO ROOF SHEATHING INSPECTION. 23. THE APPLICANT/OWNER SHALL BE RESPONSIBLE FOR CONFIRMING ALL EXISTING EASEMENTS AND/OR CLEARANCES ON -SITE THAT MAY AFFECT THE PROJECT. 2 THE PROPOSED PROJECT IS A NEW 800 SF DETACHED ADU AND CONSIST OF: - 2 BEDROOMS, 2 BATHROOMS. - KITCHEN, DINING, LIVING ROOM. - FRONT PORCH: 60 SF - NEW CENTRAL AC, NEW HEATPUMP WATER HEATER, NEW AIR HANDLERS. - DUAL-GANG METER, 225 APM SUB-PANEL. EXISTING PERMIT REQUIRED: STORAGE AND A/C CONDENSER THE CURRENT PREVAILING BUILDING AND CONSTRUCTION CODES ARE AS FOLLOWS: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE REGULATION OF THE STATE AND LOCAL FIRE MARSHALS & CITY ORDINANCE .CITY OF SANTA ANA AMENDMENTS AND MUNICIPAL CODE. LEGAL JURISDICTION : CITY OF SANTA ANA, CA 92703 THE DESIGN OF THE ACCESSORY DWELLING UNIT SHALL BE ARCHITECTURALLY COMPATIBLE WITH THE MAIN DWELLING UNIT, WITH ALL DESIGN. THE DESIGN, COLOR, MATERIAL AND TEXTURE OF THE ROOF SHALL BE SUBSTANTIALLY THE SAME AS THE MAIN DWELLING UNIT. 2.07 kWdc PV SYSTEM WILL BE UNDER A SEPARATE PERMIT THE MAIN ELECTRICAL SERVICE PANEL RATING OF 225AMPS. THE MAIN SERVICE PANEL SHALL HAVE A MINIMUM BURSAR A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE SOLAR ELECTRIC INSTALLATION. THE RESERVED SPACE SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION AND SHALL BE PERMANENTLY MARKED AS "FOR FUTURE SOLAR ELECTRIC". SOLAR PV SYSTEM MUST BE APPROVED REQ BUILDING DIVISION PRIOR ROOF SHEATHING INSPECTION. PL 60.00' PL 1 1 1 . 9 8 ' PL 1 1 1 . 9 8 ' PL 60.00' RE A R S E T B A C K 7' - 0 " 27 ' - 7 " SE P A R A R T I O N 10 ' - 0 " (E ) 37 ' - 4 1 / 2 " (E ) 30 ' - 0 " 30 ' - 0 " T O C E N T E R L I N E (E) SETBACK 4'-1" (E) 46'-6" (E) SETBACK 9'-5" (E ) 37 ' - 0 " (E ) 30 ' - 4 1 / 2 " (E ) S E P A R A T I O N 13 ' - 7 " (E ) 20 ' - 0 " (E ) 11 ' - 0 1 / 2 " FR O N T R E Q . S E T B A C K 20 ' - 0 " SETBACK 5'-0"29'-4" SEPARATION 6'-0" (E) 18'-0" (E) 1'-6" (E) GARAGE 360 SF (E) MAIN HOUSE 1402 W 10TH ST, SANTA ANA, CA 92703 1,290 SF (E) ENTRY PORCH 143 SF 10TH ST STREET CENTERLINE (E ) 5' - 0 " (E ) 7' - 0 " (E ) 18 ' - 0 " (E) STORAGE TO BE LEGALIZED - 74 SFF. S . D 5' - 0 " F. S . D 5' - 0 " F.S.D 3'-0" F.S.D 3'-0" (N) DETACHED ADU 1402 W 10TH ST, UNIT 2, SANTA ANA, CA 92703 800 SF (E) 24'-8" (E) 21'-10" ENTRY PORCH 60 SF 4'-0" 1'-0" 6' - 0 " 1' - 0 " 4' - 0 " 4' - 0 " 1' - 0 " (E ) 1' - 0 " 1'-0" 2'-0" 2'-0" (E) 1'-0" (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " 7' - 0 " 2' - 6 " 2' - 6 " (E) 16'-0" 16 17 15 18 18 14 13 10 3 6 6 3 2 2 2 18 1 1.1 9 5 12 11 8 (E ) C L E A N -OU T ( V . I . F ) (N ) C L E A N -OU T (E) WA L K W A Y (E) 3'-1" (E) 1'-0" (E) 1'-0" (E) 8'-5" UPGRADE TO 1HR FIRE RATED WALL (E) 8'-0" 5FT PUBLIC UTILITY EASEMENT EX C E S S DR I V E W A Y T O B E AD D R E S S E D A T A LA T E R T I M E 3 18 9 bl o c k w a l l 3 f t h e i g h t 16 AD.10 9 AD.10 EXCESSIVE CONCRETE (E) POWER POLE 17 AD.10 17 AD.10 1 2 (E) BLOCK WALL 6FT HEIGHT 3 4 5 6 7 8 9 10 11 12 13 DRIVEWAY, ON DRIVEWAY PARKING 10'X20' PER SPACE (E) LANDSCAPE (E) TREE TO BE REMOVED (E) A/C UNIT TO BE LEGALIZED (E) GATE (E) MAIN HOUSE 200AMP ELECTRICAL PANEL (E) WATER METER 1.1 (E) GAS METER (E) MAIN HOUSE ELECTRICAL METER (E) WALKWAY ROOF LINE ABOVE (N) WATER METER (1" MINIMUM PER CITY REQUIREMENT) (N) GAS METER 14 (N) CONSUMER TANK W/ HEATPUMP 15 (N) HEATPUMP UNIT ON 3" THICK CONCRETE PAD 16 (N) ELECTRICAL SUB-PANEL 225AMPS FOR ADU 17 (N) DUAL-GANG ELEC. METER FOR ADU 18 (N) 1HR FIRE RESISTANCE EAVE, SEE DTL 17/AD.10 19 1HR FIRE RATED WALL, SEE DETAIL 16/ AD.10 UNPROTECTED OPENING MAX 25% WALL AREA, SEE NORTH ELEVATION/ A.06 LANDSCAPE/ PLANTS (65% MINIMUM) 793/1200 = 66% PERMEABLE HARDSCAPE (35% MAXIMUM) 407/1200= 34% FRONT YARD 20FT AREA = 60 X 20= 1200 SF (*) (*) TURF A. TURF SHALL BE DROUGHT TOLERANT VARIETY AND PLANTED AS SOD OR HYDROSEED. B. GROUND COVER SHALL BE WELL-ROOTED CUTTINGS FROM FLATS AND PLANTED AT APPROPRIATE SPACING FOR THAT PARTICULAR PLANT MATERIAL. P. U . E 5' - 0 " PL 60.00' PL 1 1 1 . 9 8 ' PL 1 1 1 . 9 8 ' PL 60.00' (E ) 44 ' - 7 1 / 2 " (E ) 37 ' - 4 1 / 2 " (E ) 30 ' - 0 " 30 ' - 0 " T O C E N T E R L I N E (E) SETBACK 4'-1" (E) 46'-6" (E) SETBACK 9'-5" (E ) 37 ' - 0 " (E ) 30 ' - 4 1 / 2 " (E ) S E P A R A T I O N 13 ' - 7 " (E ) 20 ' - 0 " (E ) 11 ' - 0 1 / 2 " FR O N T R E Q . S E T B A C K 20 ' - 0 " (E) 18'-0" (E) 1'-6" (E) GARAGE 360 SF (E) MAIN HOUSE 1402 W 10TH ST, SANTA ANA, CA 92703 1,290 SF (E) ENTRY PORCH 143 SF 10TH ST STREET CENTERLINE (E ) 5' - 0 " (E ) 7' - 0 " (E ) 18 ' - 0 " (E) STORAGE 74 SF(E) 24'-8" (E) 21'-10" (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " (E) 16'-0" 10 3 6 3 2 2 2 1 1.1 9 5 11 8 (E ) C L E A N -OU T ( V . I . F ) (E) WA LK W A Y (E) 3'-1" (E) 1'-0" (E) 1'-0" (E) 8'-5" (E) OPEN SPACE 1,807 SF 6 7 (E) 8'-0" 5FT PUBLIC UTILITY EASEMENT 9 (E) POWER POLE CURB (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " EXISTING (1) 24" BOX CANOPY TREE NEW (6) 5-GAL SHRUBS (10) 1-GALLON SIZE HERBACEOUS PERENNIALS/ SHRUBS NOTE: ALL TREE SHALL BE DOUBLE-STACKED IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATE DELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/01/2024 1ST PLAN CORRECTION 2 02/22/2024 2ND PLAN CORRECTION A.00 SITE PLAN (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 SHEET INDEX SITE PLAN KEYNOTES SYMBOL CONSTRUCTION NOTES VICINITY MAPGENERAL NOTES PROJECT DATA ARCHITECTURAL A.00 SITE PLAN A.01 CAL GREEN CODE A.02 CAL GREEN CODE A.03 GENERAL DETAILS A.04 EXISTING PLANS & ELEVATIONS A.05 PROPOSED FLOOR PLAN & ROOF PLAN A.06 ELEVATIONS & SECTIONS A.07 ELECTRICAL/ LIGHTING PLAN AD.10 ARCHITECTURAL DETAILS D.01 DRAINAGE PLAN T24.1 TITLE 24 T24.2 TITLE 24 (CONT.) T-24.3 TITLE 24 (CONT.) STRUCTURAL S-0.10 GENERAL NOTES & REQUIREMENTS S-0.11 GENERAL NOTES & REQUIREMENTS S-0.12 SOIL REPORT S-0.13 SOIL REPORT S-0.14 SOIL REPORT S-0.20 TYPICAL DETAILS S-1.0 FOUNDATION & ROOF FRAMING (ADU) S-2.0 PARTIAL FOUNDATION & ROOF FRAMING PLAN (MAIN HOUSE) SD1.0 FOUNDATION DETAILS SD2.0 STRUCTURAL DETAILS SCOPE OF WORK APPLICABLE CODE ADU NOTES DEFERRED 1" = 10'-0" 2PROPOSED SITE PLAN LANDSCAPE LEGEND 1" = 10'-0" 1EXISTING SITE PLAN DIG ALERT 811 DIG ALERT (811) IS TO BE CONTACTED AND THAT COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDANCE WITH GOVERNMENT CODE 4216 WILL BE FOLLOWED PRIOR TO ANY EXCAVATION TAKING PLACE OWNER/ CONSTRACTOR ACKNOWLEDGEMENT SIGNATURE THE ADU SF/SFD SF RATIO IS FOR PARK & REC FEE PURPOSE ONLY. THE APPLICANT IS RESPNSIBLE FOR THE GIVEN "SFR SF" OF THE EXISTING PRIMARY RESIDENCE; BUILDING SAFETY STAFF ARE NOT RESPONSIBLE FOR THE ACCURACY OF THE GIVEN "SFR SF" BLDG # 101117923-24 APPROVALS PLNG - PRaj BLDG - GHuang PD- BMartin 1402 W 10th St & Unit #2 - 101117923-245/8/2024 ELECTRIC OUTLET AND LIGHT FIXTURE 20' MAX. 30" MIN. MIN. 30X30" WORKING PLATFORM SECURED IN PLACE 22x30" MIN. ATTIC ACCESS MIN. 24" WIDE SOLID FLOORING FROM ACCESS OPENING TO FURNACE WORKING PLATFORM LIGHT SWITCH 30 " M I N . 30 " M I N . ATTIC AIR HANDLER AIR HANDLER DISCONNECT AND ELECTRICAL OUTLET 1. WINDOW MANUFACTURER AND INSTALLER SHALL INSURE THAT ALL WINDOWS MEET OR EXCEED ALL EGRESS REQUIREMENTS OF CRC R310 & R312 2. ALL WINDOWS AND SLIDING GLASS DOORS SHALL BE INSTALLED PER AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION AAMA 2400=02 RECOMMENDATIONS "STANDARD PRACTICE FOR INSTALLATION OF WINDOWS WITH INTEGRAL MOUNTING FLANGES IN STUD FRAME CONSTRUCTION". 3. INSTALL AN ISOLATION MEMBRANE BELOW THE THRESHOLD OF ALL SLIDING GLASS DOORS THAT REST ON A CONCRETE SLAB. 4. ALL SEALANT SHALL BE OF HIGH QUALITY AND REVIEWED OFR COMPATIBILITY WITH ASPHALTIC MEMBRANES AND FLASHING MATERIAL. 44" MAXIMUM 24" MIN. 20" MINNIMUM F.F. > 72" ABV. FINISH GRADE. 24" MINIMUM @ 44" MAXIMUM 20" MINNIMUM F.F. > 72" ABV. FINISH GRADE. 24" MINIMUM @ 5.7 S.F MINIMUM 24" MIN. 5. 7 S . F M I N I M U M 1. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. 2. MIN. SET CLEAR HEIGHT OF 24 INCHES. 3. WINDOW SILL CLEAR OPENING EMERGENCY EGRESS NO MORE THAN 44 INCHES ABOVE THE FLOOR. EMERGENCY EGRESS WINDOW AND DOOR NOTE GENERAL NOTES 1. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, LICENSES, CONSTRUCTION TAXES AND FEES REQUIRED BY CITY, COUNTY AND STATE LAWS EXCEPT THE GENERAL BUILDING PLAN CHECK FEE AND REQUIRED REFUNDABLE DEPOSITS WHICH WILL BE PAID BY THE OWNER. CONTRACTOR SHALL ARRANGE FOR ALL METER INSTALLATIONS AND PAY ALL FEES FOR SAID METERS. CONTRACTOR SHALL PROVIDE TEMPORARY TOILET FACILITIES AND EROSION CONTROL MEASURES AS REQUIRED BY STATE AND LOCAL BUILDING CODE. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR HAVING COMPLETE KNOWLEDGE OF EXISTING CONDITIONS. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS WITH THOSE SHOWN ON THE DRAWINGS AND SHALL VERIFY GRADES, CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING DEMOLITION AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF DISCREPANCIES BETWEEN ACTUAL CONDITIONS AND THOSE DEPICTED IN THE CONTRACT DOCUMENTS. CONTRACTOR SHALL NOTIFY ARCHITECT IMMEDIATELY VERBALLY AND IN WRITING OF ANY DISCREPANCIES FOUND WITHIN THE DRAWINGS AND SPECIFICATIONS. 3. CONTRACTOR IS SOLELY RESPONSIBLE FOR THE ACCURACY OF DETAILS; FOR CONFIRMING AND COORDINATING ALL QUANTITIES AND DIMENSIONS; FOR SELECTING FABRICATION PROCESSES; FOR TECHNIQUES OF ASSEMBLY AND PERFORMANCE OF ALL WORK IN A SAFE AND SATISFACTORY MANNER. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL WORK INCLUDING THAT OF THE SUB-CONTRACTORS. CONTRACTOR SHALL PROVIDE SUPERVISION OF THE JOB DURING ALL PHASES OF CONSTRUCTION ACTIVITIES. A COMPETENT SUPERINTENDENT SHALL BE SELECTED BY THE CONTRACTOR AND SHALL BE IN CHARGE OF THE JOB UNTIL ITS COMPLETION. CONTRACTOR AGREES TO BIND EVERY SUB-CONTRACTOR BY THE TERMS OF THE CONTRACT AS FAR AS SUCH TERMS ARE APPLICABLE TO THE SUB-CONTRACTOR'S WORK. 4. CONTRACTORS SHALL BE RESPONSIBLE FOR THE DAILY REMOVAL OF ALL DEBRIS ACCUMULATED AS A RESULT OF THEIR OPERATIONS. ALL SCRAP DEBRIS AND OTHER EXCESS MATERIAL SHALL BE LAWFULLY REMOVED FROM THE SITE, UNLESS OTHERWISE DIRECTED BY THE CONTRACTOR. 5. CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS AND PRODUCTS FOR ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE WORK AND CONTRACTOR SHALL REPAIR OR REPLACE, OR CAUSE TO BE REPAIRED OR REPLACED ANY OR ALL SUCH WORK TOGETHER WITH ANY OTHER WORK WHICH MAY BE DISPLACED IN DOING SO, THAT MAY PROVE DEFECTIVE WITHIN ONE YEAR, WITHOUT ADDITIONAL EXPENSE; ORDINARY WEAR AND TEAR, UNUSUAL ABUSE OR NEGLECT IS EXCEPTED. EXCEPTIONS TO ONE YEAR GUARANTEE ARE SPECIFIED IN OTHER SECTIONS OF THE PROJECT MANUAL OR DRAWINGS. STATE LAW, OR MANUFACTURER'S GUARANTEE SHALL GOVERN IF LENGTH AND TYPES OF GUARANTEES ARE MORE STRICT OR FOR LONGER PERIODS. 6. THAT IS RESPONSIBILITY OF CONTRACTOR TO PROVIDE MATERIALS AND CONSTRUCTION WHICH WILL YIELD A REASONABLE VALUE OVER A PERIOD OF TIME WHICH MAY EXCEED THE SPECIFIED GUARANTEE AND WARRANTY PERIODS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR A WEATHER TIGHT BUILDING, FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP. EACH SUB- CONTRACTOR SHALL PROVIDE A WRITTEN GUARANTEE STATING THAT WORK EXECUTED BY HIM IS FREE AND WILL REMAIN FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR ONE YEAR FROM DATE OF ACCEPTANCE OF HIS WORK BY OWNER, AND THAT REPAIR AND REPLACEMENT OF SUCH DEFECTIVE WORK AND ALL OTHER WORK DAMAGED AS A RESULT THEREBY WILL BE EXECUTED IN A TIMELY MANNER AT THE CONVENIENCE OF THE OWNER AND WITHOUT COST TO OWNER. 8. THE ARCHITECT WILL NOT ACT AS THE OWNER'S REPRESENTATIVE DURING CONSTRUCTION. ARCHITECT WILL ADVISE AND CONSULT WITH OWNER. ARCHITECT WILL OBSERVE CONSTRUCTION PER HIS AGREEMENT WITH OWNER AND RENDER INTERPRETATIONS NECESSARY FOR THE PROPER EXECUTION OR PROGRESS OF THE WORK IN ACCORDANCE WITH THE INTENT OF THE PLANS AND SPECIFICATIONS. ARCHITECT WILL NOT BE RESPONSIBLE OR HAVE CONTROL OR CHARGE OVER THE ACTS OR OMISSIONS, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES, OR FOR SAFETY PRECAUTIONS AND PROGRAMS, OF THE CONTRACTOR, SUB-CONTRACTORS, OR ANY OF THEIR AGENTS OR EMPLOYEES, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK. ANY VERBAL INSTRUCTION OR AUTHORIZATION THAT IS CONFIRMED BY LETTER, MEETING NOTE, MEMORANDA, OR THE LIKE, (WITH A COPY SENT TO THE OWNER, OR THE OWNER'S REPRESENTATIVE) & THERE IS NO EXCEPTION TAKEN WITHIN (10) CALENDAR DAYS, SHALL BE DEEMED EQUIVALENT TO RECEIPT OF WRITTEN INSTRUCTION, APPROVAL AND AUTHORIZATION FROM THE OWNER. 9. OWNER MAY ORDER EXTRA WORK OR MAKE CHANGES BY ALTERING, ADDING TO OR DEDUCTING FROM THE WORK, THE CONTRACT SUM BEING ADJUSTED TO THE MUTUAL SATISFACTION OF THE OWNER, ARCHITECT AND CONTRACTOR. BEFORE ANY CHANGES ARE BEGUN, THE ADDED OR DEDUCTED SUM SHALL BE PRESENTED TO OWNER IN WRITING FOR APPROVAL. 10. SUBSTITUTIONS OF MATERIALS OR METHODS PROPOSED BY THE CONTRACTOR OR HIS SUB-CONTRACTORS CONTRARY TO DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO ARCHITECT IN W RITING FOR APPROVAL OR DENIAL. IF MORE THAN ONE MANUFACTURER IS SPECIFIED IN THE PLANS OR SPECIFICATIONS, IT SHALL BE THE CONTRACTOR'S OPTION TO SELECT THE ONE WHICH HE MAY DESIRE. IF MORE THAN ONE FINISH OR STYLE IS AVAILABLE IN THE ITEM SPECIFIED, CONTRACTOR SHALL BE OBLIGATED TO NOTIFY ARCHITECT VERBALLY AND IN WRITING OF THIS FACT FOR ARCHITECT'S AND OWNER'S DECISION. 11. THESE DRAWINGS AND SPECIFICATIONS SHALL BE INTENDED TO SHOW AND DESCRIBE DETAILS FOR A CONSTRUCTIBLE BUILDING. PARTS AND DETAILS NOT FULLY SHOWN OR DESCRIBED SHALL BE DETAILED AND EXECUTED ACCORDING TO STANDARD FIRST CLASS PRACTICE AND IN SIMILAR MANNER AND SPIRIT OF THE DETAILS WHICH ARE SHOWN ON THE DRAWINGS AND/OR DESCRIBED IN THE PROJECT MANUAL. IF CONTRACTOR OR SUB-CONTRACTOR FINDS ANY DETAILS WHICH, IN HIS OPINION, ARE UNSOUND, UNSAFE, OR NOT WATERPROOF, IT IS HIS DUTY TO NOTIFY ARCHITECT IN WRITING OF THIS FACT. IF WORK IS PERFORMED AS DETAILED, IT WILL BE ASSUMED THAT THERE ARE NO OBJECTIONS TO THE DETAIL. ACCURACY OF ALL DIMENSIONS SHALL BE CHECKED. NO EXTRA COMPENSATION WILL BE ALLOWED FOR DIFFERENCE BETWEEN ACTUAL DIMENSIONS AND THOSE INDICATED ON THE DRAWINGS. 12. IN USING THESE PLAN FOR BIDDING OR CONSTRUCTION PURPOSES, ALL CONTRACTORS ARE REQUIRED TO REVIEW AND TREAT THEM AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT THEIR PORTION OF THE WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE AFFECTED CONTRACTOR IS REQUIRED TO EITHER OBTAIN DIRECTION FROM AN APPROPRIATE REPRESENTATIVE OF THE OWNER, OR OTHERWISE TO APPLY THE MORE STRINGENT STANDARD. 13. THESE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION. ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED, AND ALL CONTRACTORS ARE REQUIRED TO CAREFULLY REVIEW THESE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS TO THE ATTENTION OF A APPROPRIATE OWNER & ARCHITECT IN WRITING IN A TIMELY MANNER; AND ANY CONTRACTOR WHO FAILS TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING ASSUMES THE RISK OF ANY CONSEQUENCES. SCALED DIMENSIONS SHOULD BE CONSIDERED ONLY APPROXIMATE; AND IN ANY DIMENSIONS BEFORE PROCEEDING WITH ANY AFFECTED PROCUREMENT, FABRICATION OR CONSTRUCTION. 14. FIGURED DIMENSIONS SHALL BE FOLLOWED IN PREFERENCE TO SCALE, AND DETAIL DRAWINGS IN PREFERENCE TO SMALL SCALE DRAWINGS. SUB- CONTRACTOR AND CONTRACTOR SHALL CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD PRIOR TO ANY WORK BEING CONSTRUCTED OR MATERIALS OR PRODUCTS FABRICATED OR ORDERED. SPECIFICATIONS AND WRITTEN NOTES AND SCHEDULES ON DRAWINGS SHALL BE FOLLOWED IN PREFERENCE TO INFORMATION FURNISHED IN THE FORM OF LINE DRAWINGS. DETAILED DRAWINGS FURNISHED DURING CONSTRUCTION OR APPROVED BY CONTRACTOR OR ARCHITECT ARE TO BE CONSIDERED EXPLANATORY AND NOT AS CHANGES TO DRAWINGS AND SPECIFICATIONS. NOTES, FIGURES AND DETAILS ON SAID DRAWINGS SHALL BE FOLLOWED AND EXECUTED AS IF PART OF THESE DOCUMENTS. 15. ERRORS OR OMISSIONS WHICH APPEAR ON THE DRAWINGS, IN SPECIFICATIONS OR OTHER CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR AND TO THE CONTRACTOR BY THE SUB-CONTRACTOR IN WRITING. IN EVENT OF FAILURE OF SUB-CONTRACTOR TO GIVE SUCH WRITTEN NOTIFICATION BEFORE CONSTRUCTION OR FABRICATIONS OF THE WORK, HE WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COSTS OF RECTIFYING SAME. HOWEVER, DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WORK CALLED FOR ON ONE AND NOT THE OTHER SHALL BE PROVIDED AS THOUGH FULLY SET FORTH IN BOTH. 16. AT ALL TIMES DURING CONSTRUCTION ACTIVITIES OR ERECTION OF PROJECT OR ITS COMPONENT PARTS, PRIOR TO COMPLETION OF THE STRUCTURAL FRAME OR REPLACEMENT AND PERMANENT CONNECTION OF COMPONENT MEMBERS TO THE STRUCTURAL FRAME, SUB- CONTRACTORS SHALL PROVIDE, INSTALL AND MAINTAIN PROPERLY DESIGNED AND CONSTRUCTED TEMPORARY BRACING OF ADEQUATE STRENGTH TO PREVENT DISLOCATION, DISTORTION, CRACKING, FALLING OFF, OR ANY OTHER DAMAGE TO WORK OR ANY OF ITS COMPONENT PARTS DUE TO FORESEEABLE NORMAL AS WELL AS NOT FORESEEABLE EXCESSIVE WIND AND EARTHQUAKE FORCES WITHOUT ADDITIONAL COST TO OWNER. CONTRACTOR AND HIS SUB-CONTRACTORS SHALL, AT THEIR EXPENSE, REPLACE OR REPAIR, AS DIRECTED, DAMAGED PORTIONS OF THEIR WORK OR COMPONENT PARTS. 17. NO CHANGES ARE TO BE MADE ON THESE PLANS WITHOUT THE KNOWLEDGE OR CONSENT OF THE ARCHITECT/ ENGINEER WHOSE SIGNATURE APPEARS HERON. 18. NO FRAMING OF ANY TYPE TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AGENCIES. 19. REFERENCES TO ANY DETAIL OR DRAWINGS IS FOR CONVENIENCE ONLY AND DOES NOT LIMIT THE APPLICATION OF SUCH DETAIL OR DRAWINGS. 20. THE BUILDER SHALL PROVIDE TO THE BUILDING OWNER AT OCCUPANCY MAINTENANCE INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS, AND MANUFACTURED INFORMATION FOR ALL FEATURES, MATERIALS, COMPONENTS AND MANUFACTURED DEVICES THAT REQUIRE ROUTINE MAINTENANCE FOR EFFICIENT OPERATION. REQUIRED ROUTINE MAINTENANCE ACTIONS SHALL BE CLEARLY STATED AND INCORPORATED ON A READILY ACCESSIBLE LABEL. THE LABEL MAY BE LIMITED TO IDENTIFYING, BY TITLE AND/OR PUBLICATION NUMBER, THE OPERATION AND MAINTENANCE MANUAL FOR THAT PARTICULAR MODEL AND TYPE OF FEATURE, MATERIAL, COMPONENT, OR MANUFACTURED DEVICE. 21. AFTER INSTALLING WALL, CEILING, OR FLOOR INSULATION, THE INSTALLER SHALL MAKE AVAILABLE TO THE ENFORCEMENT AGENCY OR POST IN A CONSPICUOUS LOCATION IN THE BUILDING A CERTIFICATE SIGNED BY THE INSTALLER STATING THAT THE INSTALLATION IS CONSISTENT WITH THE PLANS AND SPECIFICATIONS FOR WHICH THE BUILDING PERMIT WAS ISSUED. THE CERTIFICATE SHALL ALSO STATE THE MANUFACTURER'S NAME AND MATERIAL IDENTIFICATION, THE INSTALLED R-VALUE, AND (IN APPLICATIONS OF LOOSE FILL INSULATION) THE MINIMUM INSTALLED WEIGHT PER SQUARE FOOT CONSISTENT WITH THE MANUFACTURER'S LABELED INSTALLED DESIGN DENSITY FOR THE DESIRED R-VALUE. 22. INSPECTOR TO REVIEW AND APPROVE UNDERGROUND ELEC. SERVICE PRIOR TO CONCRETE PLACEMENT. 23. ISSUANCE OF A BUILDING PERMIT DOES NOT RELIEVE APPLICANTS OF THE LEGAL REQUIREMENTS TO OBSERVE COVENANTS, CONDITIONS AND RESTRICTIONS WHICH MAY BE RECORDED AGAINST THE PROPERTY OR TO OBTAIN PLANS. YOU SHOULD CONTACT YOUR COMMUNITY ASSOCIATIONS PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION AUTHORIZED BY THIS PERMIT. 24. GENERAL CONTRACTOR, CONTRACTORS, SUB-CONTRACTORS AND BUILDERS TO COORDINATE ALL ENGINEERING AND MECHANICAL DRAWINGS WITH ARCHITECTURAL DRAWINGS BEFORE PROCEEDING WITH WORK. IF DISCREPANCIES ARE APPARENTLY OBSERVED OR INFORMATION APPARENTLY IS THOUGHT TO BE MISSING, NOTIFY ARCHITECT WITHIN 24 HOURS WITH SKETCH, DRAWING, PDF, PHOTOCOPIES WITH LEGIBLE HAND WRITTEN NOTES AND/OR WRITING (FAX, EMAIL OR CORRESPONDENCE). IF CONFLICT WITH EXISTING CONDITIONS, PROVIDE DOCUMENTATION (PHOTOS, SKETCHES, DWGS) OF EXISTING CONDITIONS AND SUGGEST PROPOSAL(S) FOR SOLUTION (SKETCH, DRAWING, AND/OR WRITING). U UNDER U.B.C.UNIFORM BUILDING CODE U.G.UNDERGROUND U.L.UNDERWRITER'S LABORATORY UNF.UNFINISHED U.N.O.UNLESS NOTED OTHERWISE UR.URINAL V.VERTICAL VENT.VENTILATING VERT.VERTICAL VER.VERIFY V.T.R.VENT THROUGH ROOF W.WEST, WIDE, WIDTH W/.WITH WD.WOOD W.H.WATER HEATER W.C.WATER CLOSET W.I.WROUGHT IRON WP.WATERPROOF W.W.M.WELDED WIRE MESH &AND <ANGLE @ AT C CENTERLINE ∅DIAMETER OR ROUND PL PROPERTY LINE, PLATE A.B.ANCHOR BOLT ABV.ABOVE A/C AIR CONDITIONING A.C.ASPHALT CONCRETE ACOUS.ACOUSTICAL A.D.AREA DRAIN ADH.ADHESIVE ADJ.ADJUSTABLE AL.ALUMINUM ALT.ALTERNATE ANOD.ANODIZED A.P.ACCESS PANEL APPX.APPROXIMATELY APPV'D APPROVED ARCH.ARCHITECTURAL ASB.ASBESTOS ASSY.ASSEMBLY AUTO.AUTOMATIC B.BATH BD.BOADRD BEL.BELOW BET.BETWEEN BITUM.BITUMINOUS BLDG.BUILDING BLK.BLOCK BLK'G BLOCKING BM.BEAM B.O.BY OWNER/BY OTHERS BOT.BOTTOM BR.BEDROOM B.W.BACK OF WALK/ BOT. OF WALL CAB.CABINET C.B.CATCH BASIN CEM.CEMENT C.G.CORNER GUARD CHAN.CHANNEL CHG.CHANGE C.I.CAST IRON C.J.CONTROL JOINT/ CONST. JOINT CLG.CEILING/ CEILING JOIST CLKG.CAULKING CLR.CLEAR CNTR.COUNTER CONC.CONCRETE COND.CONDITION CONST.CONSTRUCTION CONT.CONTRACTOR/ CONTINOUS CORR.CORRIDOR, CORROSIVE CTSK.COUNTERSUNK CTR.CENTER DBL.DOUBLE DECO.DECORATIVE DEPT.DEPARTMENT DET.DETAIL D.F.DRINKING FOUNTAIN/ DOUGLASS FIR DIA.DIAMETER DIAG.DIAGONAL DIM.DIMENSION DN.DOWN DR.DOOR D.S.DOWN SPOUT D.S.P.DRY STAND PIPE DWG.DRAWING (E.)EXISTING/ EAST/ ENTRY/ EACH E.J.EXPANSION JOINT EL.ELEVATION ELEC.ELECTRIC ELEV.ELEVATOR EMER.EMERGENCY ENCL.ENCLOSURE E.P.ELECTRIC PANEL E.Q.EQUAL/ EQUIVALENT EQPT/ EQPM EQUIPMENT E.W.EACH WAY EXST.EXISTING EXH.EXHAUST EXPO.EXPOSED EXT.EXTERIOR E.G.EXISTING GRADE F.FIXED F.A.FIRE ALARM FAC.FACTORY F.C.O.FLOOR CLEAN OUT F.D.FLOOR DRAIN FDN.FOUNDATION F.E.FIRE EXTINGUISHER F.E.C.FIRE EXTINGUISHER CABINET F.G.FINISH GRADE F.H.FLAT HEAD FIN.FINISH FIX/FIXT FIXTURE F.J.FLOOR JOIST F.L.FLOW LINE FLASH.FLASHING FLR.FLOOR FLUOR.FLUORESCENT F.O.C.FACE OF CONCRETE/ FACE OF CURB F.O.F.FACE OF FINISH F.O.S.FACE OF STUD/ FACE OF STRUCUTRE F.O.M.FACE OF MASONRY FP.FIREPLACE F.S.FLOOR SINK FT.FOOT OR FEET FTG.FOOTING FURR.FURRING FUT.FUTURE F.V.FIELD VERIFY GA.GAUGE GALV.GALVANIZED G.B.GRAB BAR/GRADE BEAM G.C.GENERAL CONTRACTOR GEN.GENERAL G.F.I.GROUND FAULT INTERRUPT G.I.GALVANIZED IRON G.L.GLASS G.L.B.GLU-LAM BEAM GND.GROUND GR.GRADE GYP.GYPSUM G.P. GRADE PLANE H.HIGH H.B.HOSE BIB H.C.HOLLOW CORE HD.HARD HDR.HEADER HDWD.HARDWOOD HDWR.HARDWARE H.M.HOLLOW METAL HORIZ.HORIZONTAL HR.HOUR HT./HGT.HEIGHT HVAC HEATING VENTILATING/ AIR COND. I.D.INSIDE DIAMETER/ INTERIOR DESIGNER IN.INCH INSUL.INSULATION INT.INTERIOR INV.INVERT/ INVERTED JAN.JANITOR JT.JOINT JST.JOIST KIT.KITCHEN L.LOW/LINEN L.A.LANDSCAPED AREA LAB.LABORATORY LAM.LAMINATE LAV.LAVATORY LBS.POUNDS LFA.LOAD FROM ABOVE L.H.LEFT HAND LKR.LOCKER LT.LIGHT LUM.LUMINOUS MAINT.MAINTENANCE MAS.MASONRY MAT.MATERIAL MAX.MAXIMUM M.B.METAL BOLT M.C.MEDICINE CABINET MECH.MECHANICAL MEMB.MEMBRANE MET/MTL.METAL MFR/MFGR MANUFACTURER M.H.MAN HOLE MIN.MINIMUM MIR.MIRROR MISC.MISCELLANEOUS M.O.MASONRY OPENING MOS.MOSAIC MTD.MOUNTED MUL.MULLION (N.)NEW N.NORTH NAT.NATURAL N.I.C.NOT IN CONTRACT N.G.NATURAL GRADE NO.NUMBER NOM.NOMINAL N.T.S.NOT TO SCALE O/.OVER O.A.OVERALL OBS.OBSCURE O.C.ON CENTER O.D.OUTSIDE DIAMETER/ DIMENSION O.F.D.OVERFLOW DRAIN OFF.OFFICE OPNC.OPENING OPP.OPPOSITE PERIM.PERIMETER PL.PLATE/PROPERTY LINE P.LAM.PLASTIC LAMINTE PLAS.PLASTER PLUMB.PLUMBING PLYWD PLYWOOD PNT.PAINT P.O.C.POINT OF CONNECTION PR.PAIR PROJ.PROJECTION PSL.PARALLEL STRAND LAMINATE PT.POINT R.A.RETURN AIR RAD.RADIUS R.D.ROOF DRAIN R.D.L.ROOF DRAIN LEADER RECPT.RECEPTACLE RECT.RECTANGULAR REF.REFERENCE REFR/ R/F REFRIGERATOR REG.REGISTER REINF.REINFORCEMENT REQ'D.REQUIRED RESIL.RESILIENT' RET.RETAIN(ING), RETURN RM.ROOM R.O.ROUGH OPENING R.R.ROOF RAFTER RWD.REDWOOD S.SOUTH S.A.SUPPLY AIR S.C.SOLID CORE S.C.D.SEAT COVER DISPENSER SCHED.SCHEDULE S.D.SUB DRAIN/ SOAP DISPENSER SEC.SECTION SEL.SELECTED SH.SHELF SHT.SHEET SHT'G.SHEATHING SIM.SIMILAR SIMP.SIMPSON S.J.SOFFIT JOIST S.S.STAINLESS STEEL S.SK.SERVICE SINK STA.STATION STD.STANDARD STL.STEEL STOR.STORAGE STRUCT.STRUCTURAL SUSP.SUSPENDED SYM.SYMMETRICAL T.TREAD T.C.TOP OF CURB T.CL.TIME CLOCK TEL.TELEPHONE TEMP.TEMPERED TER.TERRAZZO T.D.TOP OF FENCE T.&G.TONGUE AND GROOVE THK. THICK T.P.TOP OF PAVING T.PL.TOP OF PLATE T.O.S.TOP OF STRUCTURE/SLAB TRANS.TRANSFORMER T.S.TOP OF STEP T.W.TOP OF WALL TYP.TYPICAL ABREVIATION NORTH ARROW BUILDING SECTIONSHEET NUMBER SECTION NUMBER1 A1.01 BUILDING ELEVATION SHEET NUMBER ELEVATION NUMBER A1.01 1 1 A1.01 DETAIL NUMBER SHEET NUMBER XX DOOR TYPE WINDOW TYPE XX KEY NOTE REFERENCE STEP AS SLAB DOOR ID XX WINDOW ID 2" SYMBOLS LEGEND DETAIL REFFERENCE REVISION REFERENCE1REVISION NUMBER KEYNOTE NUMBER IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK 2 12/21/2023 2ND PLANCHECK A.03 GENERAL DETAILS (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 ATTIC AIR HANDLER REQUIREMENTS #GENERAL WINDOW NOTES WATER HEATER 1402 W 10th St & Unit #2 - 101117923-245/8/2024 (GAS) REF DW EXISTING CONSTRUCTION TO BE DEMOLISHED LEGEND EXISTING CONSTRUCTION TO BE REMAINED (E) BEDROOM (E) BEDROOM (E) BEDROOM (E) LIVING + DINING (E) KITCHEN (E) BATH 2 (E) BATH 1 (E) W.I.C (E) STORAGE (E) ENTRY PORCH A.04 3 A. 0 4 6 A.04 5 A. 0 4 4 DR Y E R WA S H E R 24'-8"6'-7"9'-10"5'-5" 7'-5" 19'-11 1/2" 3'-0" 11'-6 1/2" 13'-3 1/2" 11'-10" 12'-1" 37'-4 1/2" 12'-9"23'-10" 9'-11" 30'-4 1/2" 46'-6" 36'-7" 10'-6" 9'-5 1/2" 13'-3" 19'-1" 9'-6 1/2" 10'-3" 8'-0" 8'-5" 5'-10 1/ (E) AC CONDENSER UNIT TO BE LEGALIZEDTO BE LEGALIZED PORCH BELOW 4:12 4:12 2:12 1'-0" 1'-0" 1'-0"1'-0" 1'-0" 1'-0" 1'-0" 1'-0" A.04 3 A. 0 4 6 A.04 5 A. 0 4 4 (E) WALL LINE BELOW (E) WALL LINE BELOW (E) WALL LINE BELOW (E ) W A L L L I N E B E L O W (E ) W A L L L I N E B E L O W 4:12 4:12 4:12 4:12 4:12 4:12 4:12 (E) 1ST F.F 1' -0" 1ST TOP PL. 9' -0" GRADE 0' -0" (E) MAIN HOUSE APPX. HEIGHT 14' -4" (E) BUILDING HEIGHT 14'-4" 4:12 4:124:12 4:12 (E) STUCCO WALL & PAINT (E) STUCCO WALL & PAINT (E) 1ST F.F 1' -0" 1ST TOP PL. 9' -0" GRADE 0' -0" (E) MAIN HOUSE APPX. HEIGHT 14' -4" (E) BUILDING HEIGHT 14'-4" 4:124:12 4:12 (E) STUCCO WALL & PAINT (E) 1ST F.F 1' -0" 1ST TOP PL. 9' -0" GRADE 0' -0" (E) MAIN HOUSE APPX. HEIGHT 14' -4" 4:124:12 4:12 4:12 2:12 (E) BUILDING HEIGHT 14'-4" (E) STUCCO WALL & PAINT (E) STUCCO WALL & PAINT (E) 1ST F.F 1' -0" 1ST TOP PL. 9' -0" GRADE 0' -0" (E) MAIN HOUSE APPX. HEIGHT 14' -4" (E) BUILDING HEIGHT 14'-4" 4:12 4:12 4:12 (E) STUCCO WALL & PAINT IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM A.04 EXISTING PLANS & ELEVATIONS (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 1/4" = 1'-0"1EXISTING FLOOR PLAN 3/16" = 1'-0"2EXISTING ROOF PLAN 3/16" = 1'-0"3(E) NORTH ELEVATION 3/16" = 1'-0"4(E) EAST ELEVATION 3/16" = 1'-0"5(E) SOUTH ELEVATION 3/16" = 1'-0"6(E) WEST ELEVATION 1402 W 10th St & Unit #2 - 101117923-245/8/2024 AT T I C HP W/H RE F GAS DW W D HP ATTIC RE F GAS DW W D 1. VERIFY ALL APPLIANCE EQUIPMENT AND FIXTURE DIMENSIONS AND INSTALLATION REQUIREMENTS PRIOR TO CASEWORK FABRICATION INSTALLATION. 2. FINISH END WALLS OF CABINETS FLANKING OPENING TO MATCH CABINET FACE. PRIME & PAINT EXPOSED GYP. BD. WALL TO MATCH WALLS. INSTALL MATCHING BASE BD. 3. EXTEND FLOORING UNDER APPLIANCES RESTING ON FLOOR. 4. SHOWER COMPARTMENTS AND WALLS ABOVE BATH TUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NON-ABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES ABOVE THE DRAIN INLET. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL, UNO. 6. CEILING HEIGHTS INDICATED ARE MEASURED FROM FINISH FLOOR TO BOTTOM OF CEILING FINISH. 7. SMOKE DETECTORS WILL BE PROVIDED PER CHAPTER 3 CRC. THE SMOKE DETECTOR WILL BE HARD WIRED WITH BATTERY BACK-UP AND LOCATED (1) IN EACH BEDROOM, HALLWAYS OUTSIDE BEDROOMS, AND ON EACH STORY. SMOKE DETECTOR ALARM SOUND MUST BE AUDIBLE IN SLEEPING AREAS WHICH MAY REQUIRE INTERCONNECTED SMOKE DETECTORS WITHIN THE UNIT. SEE UTILITY PLANS FOR LOCATIONS. INSTALL AND LOCATE PER MFGR. LISTED REQUIREMENTS. 8. PROVIDE CARBON MONOXIDE DETECTOR ALARMS ON CEILINGS OR WALLS OUTSIDE SLEEPING ROOMS PER CHAPTER 3 CRC. 9. BATHROOM FANS MUST BE ENERGY STAR W/ HUMIDISTAT CONTROLLER AND MUST BE DUCTED TO THE EXTERIOR OF THE BUILDING 10. ALL NEW WINDOWS TO BE DUAL PANES TO MEET CURRENT ENERGY STANDARD REQUIREMENTS. 11. PROVIDE BACKING FOR ALL ACCESSORIES, FIXTURES AND WINDOW COVERINGS. 12. PROVIDE TWO LAYERS OF GRADE D OR 60-MINUTE GRADE D PAPER OVER ALL WOOD BASE SHEATHING AT EXTERIOR WALLS. 13. A MINIMUM 26 GAUGE, CORROSION RESISTANT OR PLASTIC WEEP SCREED WITH A MINIMUM VERTICAL FLANGE OF 3½ INCHES SHALL BE PROVIDED AT OR BELOW FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS. SCREED SHALL BE A MINIMUM OF 4 INCHES ABOVE EARTH OR 2 INCHES ABOVE PAVED AREAS. (CRC R703.7.2.1) 14. ACCESS TO ATTIC FURNACE MUST BE WITHIN 20' OF UNIT AND SHALL HAVE A CONTINUOUS SOLID WALKWAY AT LEAST 24" WIDE. A SWITCH CONTROL IS ALSO REQUIRED (CMC 304.4.1) 15. DOMESTIC DRYER MOISTURE EXHAUST DUCTS SHALL NOT EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 FEET (4267 MM), INCLUDING TWO 90 DEGREE (1.57 RAD) ELBOWS.A LENGTH OF 2 FEET (610 MM) SHALL BE DEDUCTED FOR EACH 90 DEGREE (1.57 RAD) ELBOW IN EXCESS OF TWO. 16. ALL WATER HEATER INSTALLATION LOCATIONS, REGARDLESS OF PROPOSED WATER HEATING SYSTEM, SHALL HAVE: (BEES 150.0(N)1A-D) A. A 120V ELECTRICAL RECEPTACLE THAT IS WITHIN 3 FEET FROM THE WATER HEATER. B. A CATEGORY III OR IV VENT, OR A TYPE B VENT WITH STRAIGHT PIPE. C. CONDENSATE DRAIN THAT IS NO MORE THAN 2 INCHES HIGHER THAN THE FINISH SURFACE BELOW. 17. SMOKE DETECTOR SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVE ALL ALARMS. 18. CARBON MONOXIDE DETECTOR SHALL BE INTERCONNECTED SUCH THAT THE ACTIVATION OF ONE ALARM WILL ACTIVE ALL ALARMS. KITCHEN EXHAUST FAN 85% CE OR 280 CFM SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL (N) 2X4 WALL EXHAUST FAN SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT w/ VENT 50 CFM MIN. INTERMITTENT W/ HUMIDITY CONTROL PER CMC 402.5, BETWEEN 50%-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/EXTERIOR WALL IAQ FAN MIN 46 CFM PER T-24 PANASONIC, WHISPERGREE, SELECT FAN, 50-80-110 SFM, MULTI SPEED. MODEL FV-0511VKS2, 0.5 SONE HB 3/4" HOSE BIBB WITH BACK-FLOW PREVENTOR SMOKE DETECTOR HARDWIRED w/ BATTERY BACK UP SD CARBON MONOXIDE DETECTOR ALARM HARDWIRED w/ BATTERY BACK UPCD 24X30 ATTIC ACCESS HEATPUMP + AIR HANDLER HEATPUMP UNIT ON PAD 3" MIN. ELECTRIC WATER HEATER W/ HEATPUMP 1-HOUR FIRE RATED WALL LAUNDRY DRYER EXHAUST CEILING AIR DIFFUSER ELECTRICAL PANEL/METER PER KEYNOTE WHOLE HOUSE FAN: 1200 CFM PER T-24 1 DUAL-GANG ELECTRICAL METER BOX1.1 ELECTRICAL SUB-PANEL 225 AMP 2 CONSUMER TANK W/ HEATPUMP 3 24X30 ATTIC ACCESS 4 LANDING. 1 1/2" BELOW THRESHOLD.MINIMUM 36" IN DEPTH.MIN. 2% SLOPE AWAY FROM BUILDING. 5 EXHAUST FAN FOR BATHROOM SHALL BE ENERGY STAR RATED. CEILING MOUNTED LIGHT W/VENT 50CFM MIN. INTERMITTENT W/HUMIDITY CONTROL PER CMC402.5, BETWEEN 50-80% SHALL BE DUCTED TO OUTSIDE THROUGH ROOF/ EXTERIOR WALL. 6 HEATPUMP UNIT ON 3" THICK CONCRETE PAD 8 OBSCURED,TEMPERED GLASS 9 10 7 LOUVER DOOR TO PROVIDE 100SQ.IN MAKE-UP AIR TEMPERED GLASS FUTURE INSTALLED FLOOR MOUNTED FOLDABLE GRAB BAR APPROVED PRE-FABRICATED SHOWER ENCLOSURES WALL PANELS WITH FACTORY- INSTALLED REINFORCEMENT FOR GRAB BARS. 11 12 1HR FIRE RATED WALL, SEE DETAIL #18/ AD.10 UNPROTECTED OPENING MAX 25% WALL AREA 2X8 BACKING FOR FUTURE GRAB BAR INSTALLATION 2'' SHOWER CURB. EXHAUST FAN ABOVE GAS RANGE SHALL BE 85% CE OR 280 CFM (EXHAUST THROUGH WALL)13 14 15 16 MIN. 4" DIA. TO THE OUTSIDE, EQUIPPED WITH A BACK DRAFT DAMPER. EXHAUST DUCT LENGTH IS LIMITED TO 14 FT. WITH 2 ELBOWS. [CMC 504.4.2] (EXHAUST THROUGH EXTERIOR WALL) XX DOOR TYPE, SEE SCHEDULE WINDOW TYPE, SEE SCHEDULE XX KEY NOTE FLOOR DEPRESSION XX 6" 15 " 15 " 8'-1"8'-0 1/2"2'-4 1/2"5'-4"5'-3 1/2" 29 1/2" 29'-1" 11'-0" 9'-11" 11'-1" 10'-0" 3'-0"3'-0" 4'-0" 2'-6" 2'-6" 10'-3" 5'-0 1/2" 6'-2 1/2" 5'-10" A.06 3 13'-0 1/2"5'-0"11'-0 1/2" ENTRY PORCH 60 SF 4'-9" 5'-3" 4'-11 1/2" 8'-11" 2'-6 1/2" 5'-8" 27'-4" 3 2 3 3 B B A B 4 4 6A A 1 C 5 CL O S E T CL O S E T BED 1 10FT CL'G BED 2 10FT CL'G BATH 1 10FT CL'G BATH 2 10FT CL'G HALLWAY LIVING 10FT CL'G KITCHEN 10FT CL'G A.06 1 A A.06 A A.06 16'-7 1/2" 3'-0" 16"16" 28 " 6x6 POST 6x6 POST B A.06 B A.06 A. 0 6 2 A. 0 6 4 1 1.1 SD SD SD CD HB HB 1. 5 " EE & R O EE&RO 8 12 1616 8 7 11 7 11 14 15 13 5 4 7 10 9 6 10 2 3 RANGEHOOD TO OUTSIDE DRYER EXHAUST TO OUTSIDE 2'-0" 3'-7" 1' - 0 " A 12 5'-1" 2'-6" 16 AD.10 A.06 3 4:12 4:12 4:12 4:12 4:12 PORCH BELOW 1' - 0 " 1'-0" 1' - 0 " 1'-0" WALL LINE BELOW WALL LINE BELOW WA L L L I N E B E L O W WA L L L I N E B E L O W (N) ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR #3537.OVER 30# BUILDING PAPER OVER PLYWOOD SHEATHING OVER RADIANT BARRIER OVER RAFTERS PER STRUCTURAL DWGS. ROOF COLOR AND MATERIAL TO MATCH WITH EXISTING BUILDING. SO L A R P A N E L S O'HAGIN 72 SQ.IN, TYP. A.06 1 A A.06 A A.06 B A.06 B A.06 A. 0 6 2 A. 0 6 4 ROOF ATTIC 800 SF 17 AD.10 3'-0" 3'-6 " 3'-6 1/2" 9 AD.10 17 AD.10 R327.1.1 REINFORCEMENT FOR GRAB BARS AT LEAST ONE BATHROOM ON THE ENTRY LEVEL SHALL BE PROVIDED WITH REINFORCEMENT INSTALLED IN ACCORDANCE WITH THIS SECTION. WHERE THERE IS NO BATHROOM ON THE ENTRY LEVEL, AT LEAST ONE BATHROOM ON THE SECOND OR THIRD FLOOR OF THE DWELLING SHALL COMPLY WITH THIS SECTION. 1. REINFORCEMENT SHALL BE SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2 BY 8 INCH (51 MM BY 203 MM) NOMINAL LUMBER. [11/2 INCH BY 71/4 INCH (38 MM BY 184 MM) ACTUAL DIMENSION] OR OTHER CONSTRUCTION MATERIAL PROVIDING EQUAL HEIGHT AND LOAD CAPACITY. REINFORCEMENT SHALL BE LOCATED BETWEEN 32 INCHES (812.8 MM) AND 39 1/4 INCHES (997 MM) ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWER REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES (152.4 MM) ABOVE THE BATHTUB RIM. EXCEPTIONS 1. WHERE THE WATER CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR-MOUNTED, FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE REQUIRED IN WALL FRAMING FOR PREFABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH INTEGRAL FACTORYINSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT FOR GRAB BARS IS PROVIDED. 3. SHOWER ENCLOSURES THAT DO NOT PERMIT INSTALLATION OF REINFORCEMENT AND/OR GRAB BARS SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. 4. BATHTUBS WITH NO SURROUNDING WALLS, OR WHERE WALL PANELS DO NOT PERMIT THE INSTALLATION OF REINFORCEMENT SHALL BE PERMITTED, PROVIDED REINFORCEMENT FOR INSTALLATION OF FLOOR- MOUNTED GRAB BARS ADJACENT TO THE BATHTUB OR AN ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. 5. REINFORCEMENT OF FLOORS SHALL NOT BE REQUIRED FOR BATHTUBS AND WATER CLOSETS INSTALLED ON CONCRETE SLAB FLOORS. R327.1.2 ELECTRICAL RECEPTACLE OUTLET, SWITCH AND CONTROL HEIGHTS ELECTRICAL RECEPTACLE OUTLETS, SWITCHES AND CONTROLS (INCLUDING CONTROLS FOR HEATING, VENTILATION AND AIR CONDITIONING) INTENDEDTO BE USED BY OCCUPANTS SHALL BE LOCATED NO MORE THAN 48 INCHES (1219.2 MM) MEASURED FROM THE TOP OF THE OUTLET BOX AND NOT LESS THAN 15 INCHES (381 MM) MEASURED FROM THE BOTTOM OF THE OUTLET BOX ABOVE THE FINISH FLOOR. EXCEPTIONS 1. DEDICATED RECEPTACLE OUTLETS; FLOOR RECEPTACLE OUTLETS; CONTROLS MOUNTED ON CEILING FANS AND CEILING LIGHTS; AND CONTROLS LOCATED ON APPLIANCES. 2. RECEPTACLE OUTLETS REQUIRED BY THE CALIFORNIA ELECTRICAL CODE ON A WALL SPACE WHERE THE DISTANCE BETWEEN THE FINISHED FLOOR AND A BUILT-IN FEATURE ABOVE THE FINISH FLOOR, SUCH AS A WINDOW, IS LESS THAN 15 INCHES (381 MM) R327.1.3 INTERIOR DOORS EFFECTIVE JULY 1, 2024, AT LEAST ONE BATHROOM AND ONE BEDROOM ON THE ENTRY LEVEL SHALL PROVIDE A DOORWAY WITH A NET CLEAR OPENING OF OR LESS THAN 32 INCHES (812.8 MM), MEASURED WITH THE DOOR POSITIONED AT AN ANGLE OF 90 DEGREES FROM THE CLOSED POSITION; OR, IN THE CASE OF A TWO OR THREE-STORY SINGLE FAMILY DWELLING, ON THE SECOND OR THIRD FLOOR OF THE DWELLING IF A BATHROOM OR BEDROOM IS NOT LOCATED ON THE ENTRY LEVEL. R327.1.4 DOORBELL BUTTONS DOORBELL BUTTONS OR CONTROLS, WHEN INSTALLED, SHALL NOT EXCEED 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON ASSEMBLY. WHERE DOORBELL BUTTONS INTEGRATED WITH OTHER FEATURES ARE REQUIRED TO BE INSTALLED ABOVE 48 INCHES (1219.2 MM) MEASURED FROM THE EXTERIOR FLOOR OR LANDING, A STANDARD DOORBELL BUTTON OR CONTROL SHALL ALSO BE PROVIDED AT A HEIGHT NOT EXCEEDING 48 INCHES (1219.2 MM) ABOVE EXTERIOR FLOOR OR LANDING, MEASURED FROM THE TOP OF THE DOORBELL BUTTON OR CONTROL. AGING-IN PLACE NOTES 1. ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC-ESR# 3537. COLOR & PER THE INSTALLATION OF ROOF COVERING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 2. PROJECTIONS LESS THAN 5'-0" (HOUSE WITH NO SPRINKLER) TO PROPERTY LINE TO BE 1-HOUR CONSTRUCTION, TYP. 3. ROOF VENT : SEE ROOF VENTILATION CALCULATION. ATTIC AREA: 800 SF USE BALANCE METHOD : NET VENT AREA REQUIRE : 800/300 x 144 SQ.IN. = 384 SQ.IN WHOLE HOUSE FAN: 1200 CFM -230 SQ.IN VENT NFA IS REQUIRED (144 SQ.IN PER 750 CFM) TOTAL VENT AREA REQUIRED: 384 + 230 = 614 SQ.IN NOTE: MAX. 50% ON UPPER ROOF AREA LOW: USE 5 UNITS O'HAGIN VENT (72 SQ.IN/UNIT) (1/3 LOW AREA OF ROOF) HIGHT: USE 4 UNITS O'HAGIN VENT (72 SQ.IN/UNIT) (1/3 HIGH AREA OF ROOF) DOOR/WINDOW REMARKS: (1) DOOR SHALL HAVE A MINIMUM CLEAR WIDTH OF 32" WHEN MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP,WITH THE DOOR OPEN AT 90 DEGREE. (2) DOOR SHALL HAVE A MINIMUM CLEAR HEIGHT OF 78", MEASURED FROM THE TOP OF THE THRESHOLD TO THE BOTTOM OF THE STOP (3) DOOR SHALL BE READILY OPENABLE FROM THE INSIDE THE DWELLING WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. (4) SELF-CLOSING, TIGHT FITTING, SOLID WOOD, 1-3/8'' THICK DOOR, NOT LESS THAN 20-MIN FIRERATED DOOR AT OPENING TO DWELLING (CBC 715.4.3). (5) MIN. 72'' ABOVE FINISH FLOOR IN BATHROOMS. (6) THE MANUFACTURED WINDOWS AND SLIDING DOOR SHALL HAVE A LABEL ATTACHED CERTIFIED BY THE NATIONALS FENESTRATION RATING COUNCIL (NFRC) AND COMPLIANCE WITH THE ENERGY CALCULATIONS. (7) THE LOAD RESISTANCE OF GLASS UNDER UNIFORM LOAD SHALL BE DETERMINED IN ACCORDANCE WITH ASTM E1300. (8) ALL TEMPERED GLASS (T.G.) SHALL BE ACID-ETCHED, SAND-BLASTED, CERAMIC-FIRED, ASER- ETCHED, OR EMBOSSED PER CRC 2406.3. (9) DEAD BOLT LOCKS ARE REQUIRED ON ALL EXTERIOR DOORS (INCLUDING HOUSE TO GARAGE (10) GLAZING SHALL BE SAFETY GLAZING IF LESS THAN 72" ABOVE BATHROOM FINISH FLOOR PRIVATE AREA 435 SF 45:55 RATIO OF COMMON TO PRIVATE AREAS COMMON AREA 355 SF IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK 2 12/21/2023 2ND PLANCHECK A.05 PROPOSED FLOOR PLAN & ROOF PLAN (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 FLOOR PLAN KEYNOTES FLOOR PLAN LEGEND FLOOR PLAN NOTES 1/4" = 1'-0"1ADU FLOOR PLAN 1/4" = 1'-0"2ADU ROOF PLAN DOOR SCHEDULE NUMBER DOOR SIZE QTY DESCRIPTION U-FACTOR SHGC REMARKS 1 3' - 0" x 6' - 8" 1 EXTERIOR DOOR 1 PANEL/TEMPERED GLASS, VINYL FRAME, PAINTED FINISH 0.5 ENTRY DOOR (1), (2), (3), (9) 2 3' - 0" x 6' - 8" 1 HOLLOW CORE 1 PANEL, WOOD FRAME, PAINTED FINISH INTERIOR 3 2' - 8" x 6' - 8" 3 HOLLOW CORE 1 PANEL, WOOD FRAME, PAINTED FINISH INTERIOR 4 5' - 0" x 6' - 8" 2 INTERIOR SLIDING CLOSET INTERIOR 5 4' - 8" x 6' - 8" 1 HOLLOW CORE 2 PANELS, WOOD FRAME, PAINTED FINISH PROVIDE 100SQ.IN AIR GRILL TO MAKE UP AIR 6 2' - 4" x 6' - 8" 1 STEEL DOOR LOUVER, PAINTED FINISH INTERIOR Grand total: 9 WINDOW SCHEDULE ID QTY WINDOW SIZE DESCRIPTION U-FACTOR SHGC REMARKS A 4 3' - 0" x 5' - 0" SINGLE HUNG, DUAL GLASS/ VINYL FRAME, FINISH PER MFGR. 0.3 0.23 <varies> B 3 3' - 0" x 4' - 0" SINGLE HUNG, DUAL GLASS/ VINYL FRAME, FINISH PER MFGR. 0.3 0.23 <varies> C 1 3' - 0" x 3' - 0" SINGLE HUNG, DUAL GLASS/ VINYL FRAME, FINISH PER MFGR. 0.3 0.23 Grand total: 8 ROOF PLAN GENERAL NOTES ROOF VENTILATION CALCULATION AREA PLAN RATIO 1402 W 10th St & Unit #2 - 101117923-245/8/2024 HP HP GRADE 0' -0" ADU TOP PL. 10' -8" ADU F.F 0' -8" ADU HEIGHT 15' -9 1/2" SETBACK 5'-0" F.S.D 3'-1" F.S.D 3'-1" SEPARATION 6'-2"1 A 4:124:12 4:12 10'-0" 8" ADU HEIGHT 15'-9 1/2" 5'-0" 1'-8" 3'-0" 3'-0" 6'-8" (E ) G A R A G E 1 2 3 6 TYP. 7 8 8 5 9 1'-0"4'-0" PR O P E R T Y L I N E F. S . L ADU TOP PL. 10' -8" ADU F.F 0' -8" ADU HEIGHT 15' -9 1/2" 1'-0"4'-0" SETBACK 5'-0" F.S.D 3'-1" F.S.D 3'-1" SEPARATION 6'-2" 1'-0"2'-1"2'-1"1'-0" (E) GARAGE BED 1 10FT CL'G KITCHEN 10FT CL'G LA U N D R Y CLASS I OR II VAPOR RETARDER INSTALLED ON THE WARM IN WINTER SIDE OF CEILING R-19 INSULATION R-38 INSULATION R-15 INSULATION R-15 INSULATION F. S . L 16 AD.10 17 AD.10 PR O P E R T Y L I N E 5 AD.10 5 AD.10 G C B F H F L K H D E E I J J GRADE 0' -0" ADU TOP PL. 10' -8" ADU F.F 0' -8" ADU HEIGHT 15' -9 1/2" 9'-0" CEILING HEIGHT 10'-0" 8" ADU HEIGHT 15'-9 1/2" 1'-0" PORCH KITCHEN 10FT CL'GBATH 2 10FT CL'G R-15 INSULATION R-38 INSULATION R-19 INSULATION CLASS I OR II VAPOR RETARDER INSTALLED ON THE WARM IN WINTER SIDE OF CEILING R-15 INSULATION 5 AD.10 D E E E A B G C F H F H I J 17 AD.10 1'-0" F.S.D 2'-6" F.S.D 2'-6"1'-0" F.S.L (E ) M A I N H O U S E GRADE 0' -0" ADU TOP PL. 10' -8" ADU F.F 0' -8" ADU HEIGHT 15' -9 1/2" 8" ADU HEIGHT 15'-9 1/2" 3'-0" 1'-8" 5'-0" 3'-0" A A F.S.D 5'-0" F.S.D 5'-0" (E ) M A I N H O U S E 5'-0" 1'-8" EE&RO 6.85 SF 4:12 4:124:12 1'-0" 1 4 TYP. 8 5 2 6 3 F. S . L 1'-0"4'-0"4'-0"1'-0" TYP. GRADE 0' -0" ADU TOP PL. 10' -8" 8" 10'-0" ADU F.F 0' -8" ADU HEIGHT 15' -9 1/2" ADU HEIGHT 15'-9 1/2" F.S.D 3'-1" F.S.D 3'-1" SEPARATION 6'-2" SETBACK 5'-0" 2'-8" 4'-0" 3'-0" B (E ) G A R A G E B 2'-8" 4'-0"A 6.85 SF EE&RO 1'-8" 5'-0" 3'-0" 4:12 4:12 4:12 9 9 6 TYP. 1 2 3 7 4 TYP. 2'-1"1'-0"4'-0"1'-0" 2'-1"1'-0" PR O P E R T Y L I N E F. S . L GRADE 0' -0" ADU TOP PL. 10' -8" ADU F.F 0' -8" ADU HEIGHT 15' -9 1/2" C B 6 3'-0" 3'-8" 3'-0" 2'-8" 4'-0" 3'-0" 2'-4" 6'-8" (E ) M A I N H O U S E F.S.D = 3'-1" (3'<F.S.D<5') UNPROTECTED OPENING MAX. 25% WALL AREA WALL AREA: 199 SF; OPENING AREA: 21 SF 21 / 199 = 10.5 % OK 4:12 4:12 1 7 6 8 5 4 TYP. 3 9 SF 12 SF (N) ROOF MATERIAL COVERING CLASS "A" ASPHALT SHINGLES BY CERTAINTEED ICC- ESR# 3537. COLOR & TEXTURE TO MATCH EXISTING HOUSE. (N) STUCCO, PAINT AND MATERIAL TO MATCH EXISTING (N) FASCIA & TRIMMING -PAINT TO MATCH EXISTING HOUSE (N) 2 1/2" VINYL MOLDING TRIM FOR ALL WINDOWS TO MATCH EXISTING HOUSE (N) CONCRETE LANDING (N) ROOF VENTS (N) SOLAR PANELS (N) WOOD POST TEMP. GLASS 1 2 3 4 5 6 7 8 9 A 6X8 RIDGE BOARD PER STRUCT. B 2X8 ROOF RAFTER PER STRUCT. C 2x8 CEILING JOISTS PER STRUCT D CONCRETE SLAB PER STRUCT. E FOOTING PER STRUCT. F 2x4 STUD WALL PER STRUCT. G (N) ATTIC INSULATION PER T-24 H (N) WALL INSULATION PER T-24 I WEEP SCREED FOR STUCCO, 2" ABOVE PAVED AREAS, 8" ABOVE NATURAL GRADE J K L DEPTH OF EAVE TO MATCH MAIN DWELLING, TYP. SEE DETAIL 17/AD.10 FOR 1-HR FIRE RESISTANT EAVE PROJECTION SEE DETAIL 16/AD.10 FOR 1-HR FIRE RATED WALL IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK 2 12/21/2023 2ND PLANCHECK A.06 ELEVATIONS & SECTIONS (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 1/4" = 1'-0"1ADU - NORTH ELEVATION 1/4" = 1'-0"ASECTION A-A 1/4" = 1'-0"BSECTION B-B 1/4" = 1'-0"2ADU - EAST ELEVATION 1/4" = 1'-0"3ADU - SOUTH ELEVATION 1/4" = 1'-0"4ADU - WEST ELEVATION ELEVATION KEYNOTES*NOTE: ALL EXTERIOR FINISHES MATCH AMONG THE EXISTING PRIMARY DWELLING, THE NEW ADU, AND NEW ADDITION, WHICH INCLUDES: 1. THE DESIGN, PITCH, COLOR, MATERIAL, AND TEXTURE OF THE ROOF EAVE DETAILS OF THE ADU AND ADDITION SHALL BE SUBSTANTIALLY THE SAME AS THE PRIMARY UNIT; 2. THE COLOR, MATERIAL, TEXTURE, OF ALL BUILDINGS WALLS, WINDOWS, AND DOORS OF THE ADU AND ADDITION SHALL BE SIMILAR TO AND COMPATIBLE WITH THE PRIMARY UNIT; 3. THE ARCHITECTURAL STYLE AND SCALE OF AN ADU AND ADDITION SHALL MATCH THE PRIMARY UNIT. SECTION KEYNOTES 1402 W 10th St & Unit #2 - 101117923-245/8/2024 GRAVEL BASE 10 MIL POLY VAPOR DIFFUSION RETARDER IS EXTENTED UNDER FOOTING MORTAR BED 3/4" TO 1 1/4" CONCRETE SLAB BOND COAT CERAMIC TILE 7/8" 3-COATS STUCCO/ OVER METAL LATH 2 LAYERS OF GRADE "D" BUILDING PAPER (VAPOR BARRIER) PLYWOOD SHEATHING (PER STRUCTURAL DESIGN) MIN. MIN. 3/8" CDX PLYWOOD 2X FRAMING INSULATION PER T-24 1/2" GYPSUM BOARD INTERIOR FINISH PER SCHEDULE EXTERIOR INTERIOR 1/2" GYPSUM BOARD INTERIOR FINISH PER SCHEDULE INTERIOR INTERIOR FIN. SLAB PER PLAN POLYVINYL-CHLORIDE COATED STEEL SPIRAL DUCT SIZE PER MECHANICAL ENGINEER W/ ALL JOISTS TAPED AND SEALED ANY AND ALL DUCK PENETRATIONS TO BE ABOVE 9.00 NAVD88 0' - 4" 0' - 4" VAPOR BARRIER 4" MIN. CONCRETE SURROUND ALL DUCTS GRAVEL FILL WHEN WALL IS SHEATHED ON THE EXTERIOR, LAP BOTH LAYERS OF BUILDING PAPER OVER THE WEEP SCREED FLANGE EXPOSED EARTH MIN. 26 GA. G.S. PLASTER WEEP SCREED W/ 3-1/2" VERTICAL NAILING FLANGE STUCCO OVER 1 LAYER GRADE 'D' PAPER PRESSURE TREATED WOOD PLATE SEAL TO CONCRETE W/ CONT. BEAD OF SEALANT WHEN WALL IS SHEATHED ON THE EXTERIOR, LAP BOTH LAYERS OF BUILDING PAPER OVER THE WEEP SCREED FLANGE CONC. SLAB FOOTING OR CURB CONCRETE OR IMPERVIOUS SURFACE MIN. 26 GA. G.S. PLASTER WEEP SCREED W/ 3-1/2" VERTICAL NAILING FLANGE STUCCO OVER 1 LAYER GRADE 'D' PAPER PRESSURE TREATED WOOD PLATE SEAL TO CONCRETE W/ CONT. BEAD OF SEALANT CONC. SLAB FOOTING OR CURB 5% 4'' MIN. TO FIN. NATURAL GRADE 8 '' MIN. 2'' MIN. 2% TO FIN. NATURAL GRADE 8" MIN. FLOOR FINISH, SEE SCHEDULE SEE STRUCT. DWGS FOR SLAB UNDER LAYER FACE OF STUD PORCH SLAB2" ISOLATED SLAB FROM CONC. SEE STRUCT. SLAB AND UNDER LAYER SEE STRUCT. DWGS INTERIOR FINISH, SEE SCHEDULE INTERIOR FINISH, SEE SCHEDULE 2x STUD WALL FLOOR FINISH, SEE SCHEDULE PORCH BEAM, SEE STRUCT. DWGS SOFFIT BOARD (EXTERIOR GRADE) ROOF FRAMING ROOF SHEATHING CLASS ''A'' ROOFING OVER 30# FELT BOXED OUT SOFFIT SOFFIT FRAMING 2" X 4" WOOD STUDS AT 16" WITH DOUBLE TOP PLATES, SINGLE BOTTOM PLATE; INTERIOR AND EXTERIOR SIDES COVERED WITH TYPE X GYPSUM WALLBOARD AND SHEATHING, RESPECTIVELY, 4' WIDE, APPLIED HORIZONTALLY OR VERTICALLY WITH VERTICAL JOINTS OVER STUDS, AND FASTENED WITH 2 1/4" TYPE S DRYWALL SCREWS, SPACED 12" ON CENTER. CAVITY TO BE FILLED WITH 3 1/2" " MINERAL WOOL INSULATION. PER CBC TABLE 721.1(2) ITEM 15-1.15 7/8" 3-COATS STUCCO OVER METAL LATH/WALL SIDING WHERE OCCUR. 1 LAYER OF GRADE "D" BUILDING PAPER (VAPOR BARRIER) PLYWOOD SHEATHING (PER STRUCTURAL DESIGN) MIN. MIN. 3/8" CDX PLYWOOD 2X FRAMING INSULATION PER T-24 CAUKLING ROOF RAFTER 2x FULL HEIGH FIRE BLOCK NO VENT HOLE ALLOWED SOLID FASCIA MIN. 3 1/2" MIN. 1". @ paved 2" min. @ N.G 6" min. SLOPE 5% MIN. AT N.G SLOPE 2% MIN. AT PAVED PER. PLAN CBC TABLE 721.1(2) ITEM 15-1.15 CLASS I OR II VAPOR RETARDER INSTALLED ON THE WARM IN WINTER SIDE OF CEILING VAULTED CEILING WHERE OCCUR 5/8" TYPE "X" GYP. SHEATHING FOR OVERHANGE SEE DETAIL 17 ROOFING (SEE PLAN) OVER 2 LAYERS 30# BUILDING PAPER OVER ROOF SHEATHING OVER RADIANT BARRIER OVER ROOF FRAMING 1 LAYER OF 5/8" TYPE "X" GYPSUM BOARD 10 AD.10 1-HOUR RATED CEILING 1 SEE PLAN ROOFING (SEE PLAN) OVER 2 LAYERS 30# BUILDING PAPER OVER ROOF SHEATHING OVER RADIANT BARRIER OVER ROOF FRAMING 2X BLK'G GUTTER WHERE OCCURS 1x4 OVER 2x6 FASCIA 1X4 ''V'' GROOVE T+G SOFFIT OVER 5/8'' TYPE 'X' GYP. BD WHEN LESS THAN 5'-0" TO PROPERTY LINE 2X6 FRIEZE OVER HOUSEWRAP CAULK EXT . MATERIAL OVER HOUSEWRAP COPPER FLASHING 5/8" GYP. SEE FINISH SCHEDULE 1/2" GYP. WHERE SLOPE CEILING OCCURS. ATTIC SPACE IN ROOM WOOD JOIST, GYPSUM WALLBOARD ONE LAYER OF 5/8" TYPE X GYPSUM WALLBOARD OR GYPSUM VENEER BASE SHALL BE INSTALLED PERPENDICULAR TO THE CEILING FRAMING AND SHALL BE FASTENED AT MAXIMUM 6 INCHES O.C. BY MIN. I 7/8 INCHES 6D COATED NAILS OR EQUIVALENT DRYWALL SCREWS REQ'D FIRE BARRIER CRC SEC. R302.6 OCCUPANCY SEPARATION IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 02/01/2024 1ST PLAN CORRECTION AD.10 ARCHITECTURAL DETAILS (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 N/A 6VENT THROUGH ROOF N/A 8CERAMIC TILE / CONCRETE N/A 11DOOR HEAD/JAM N/A 12DOOR JAM AT EXT. WALL N/A 13WINDOW HEAD-STUCCO N/A 14WINDOW JAM-STUCCO N/A 15WINDOW SILL N/A 1EXTERIOR WALL 1" = 1'-0"3INTERIOR WALL N/A 4UNDER SLAB DUCT SYSTEM N/A 5WEEP SCREET N/A 2HOUSE TO PORCH N/A 7NON-BEARING WALL N/A 9PORCH CEILING SOFFIT N/A 161HR EXT. WALL AND ROOF OVERHANG N/A 17EAVE DETAIL N/A 101-HOUR RATED CEILING 1 1402 W 10th St & Unit #2 - 101117923-245/8/2024 THE CONTRACTOR SHALL CONFORM TO ALL STATE AND LOCAL LAWS GOVERNING THE WORK AND OBTAIN ALL NECESSARY LICENSES AND PERMITS. CONCRETE SHALL BE SUPPLIED AND PLACED IN ACCORDANCE WITH THE LATEST EDITION OF ACI 318 AND ACI 301 EXCEPT AS MODIFIED BY THE CONSTRUCTION DOCUMENTS. PORLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE V, U.N.O. REINFORCING STEEL SHALL CONFORM TO ASTM A615OR ASTM 716(WELDABLE STEEL) AND SHALL BE GRADE 60 DEFORMED BARS, TYP., U.N.O. REINFORCING IN SLAB ON GRADE MAYBE GRADE 40 STEEL FOR BARS #4 AND SMALLER U.N.O ON THE PLANS. THE CONCRETE COMPRESSIVE STRENGTH (28 DAYS), f'c: a. ALL LOCATIONS, U.N.O: MIN 4000 PSI, (W/C = 0.45) SPECIAL INSPECTION IS REQUIRED WHEN f'c > 4000 PSI. b. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.1% BY WEIGHT: 4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. c. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.2% BY WEIGHT: 4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. THE CONTRACTOR SHALL CONFORM TO ALL RECOMMENDATIONS AND CONDITIONS INDICATED IN THE GEOTECHNICAL REPORT. THE GEOTECHNICAL ENGINEER SHALL OBSERVE ALL FOOTING EXCAVATIONS PRIOR TO PLACING CONCRETE OR STEEL. WAITING PERIOD FOR CONCRETE SLABS-ON-GRADE PRIOR TO START OF CONSTRUCTION IS AS FOLLOWS: a. DO NOT WALK ON SLAB UNTIL 24 HOURS AFTER CONCRETE HAS BEEN POURED. b. BEGIN WALL FRAMING 4-5 DAYS AFTER CONCRETE POURED. c. BEGIN ROOF/FLOOR FRAMING 7-10 DAYS AFTER CONCRETE POURED. d. DO NOT LOAD ROOF PRIOR TO 14 DAYS AFTER CONCRETE POURED. 1 1. 2. 1. AGGREGATE FOR STONE CONCRETE SHALL CONFORM TO ASTM C-33. FOR LOW SHRINKAGE AGGREGATE, USE LIMESTONE OR GRANITE. AGGREGATE FOR LIGHTWEIGHT CONCRETE SHALL CONFORM TO ASTM C-330. REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH ACI 315 AND ACI 318, AND CRSI'S MANUAL OF STANDARD PRACTICE. WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. LAPS IN WWF SHALL BE SUCH THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRE OF EACH FABRICH SEET IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 INCHES. 1. PRIOR TO THE CONTRACTOR REQUESTING A BUILDING DEPARTMENT FOUNDATION INSPECTION, THE GEOTECHNICAL ENGINEER SHALL ADVISE THE BUILDING OFFICIAL IN WRITING THAT: a. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE REPORT. b. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACKFILLED AND COMPACTED c. THE FOUNDATION EXCAVATIONS COMPLY WITH THE INTENT OF THE REPORT. ALL GRADE BEAMS SHALL BE POURED MONOLITHICALLY FOR THEIR ENTIRE LENGTH. PROJECT DESIGN CRITERIA BUILDING CODE 2022 CBC OCCUPANCY CATEGORY II GEOTECHNICAL ENGINIEER GEOTECHNICAL INVESTIGATION REPORT NUMBER 23-310 DATE DECEMBER 21, 2023 ALLOWABLE SOIL BEARING PRESSURE 2100 PSF SITE CLASS D SHORT PERIOD SPECTRAL ACCELERATION, S 1 1ST PERIOD SPECTRAL ACCELERATION, S D-Default SHORT PERIOD ACCELERATION PARAMETER, S 1.305 1 SECOND ACCELERATION PARAMETER, S 0.465 SEISMIC RESPONSE COEFFIECIENT, C 1.044 0.569 RESPONSE MODIFICATION FACTOR, R 6.5 0.161 SEISMIC DESIGN CATEGORY PLYWOOD SHEAR WALL SEISMIC IMPORTANCE FACTOR, I LATERAL FORCE RESISTING SYSTEM GEOTECHNICAL PARAMETERS SEISMIC DESIGN PARAMETERS S DS D1 S WIND DESIGN PARAMETERS BASIC DESIGN WIND SPEED EXPOSURE E 95 MPH C VERTICAL (GRAVITY) DESIGN PARAMETERS: (PSF) (LIVE LOADS ARE REDUCIBLE, U.N.O.) Dead Roof live Snow Live 20 20 -Roof A.B. ANCHOR BOLT ABV. ABOVE BAR. REINF. BAR BD. BOARD BLK'G. BLOCKING BLW. BELOW BM. BEAM B.N. BOUNDARY NAIL B.O.B BOTTOM OF BEAM B.W. BOTH WAYS CANT.CANTILEVER CJ. CEILING JOIST COL. COLUMN CONC. CONCRETE CONT. CONTINUOUS DBL. DOUBLE D.F. DOUGLAS FIR DIA. DIAMETER (E) EXISTING E.W. EACH WAY E.J. EXPANSION JOINT E.N. EDGE NAIL E.Q. EQUAL F.G. FINISH GRADE F.J. FLOOR JOIST FL. FLUSH F.N. FIELD NAIL F.O.C. FACE OF CONCRETE F.O.M. FACE OF MASONRY F.O.S. FACE OF STUDS GA. GAUGE GALV. GALVANIZED ALL DIMENSIONS ON STRUCTURAL DRAWINGS SHALL BE CHECKED AGAINST ARCHITECTURAL DIMENSIONS. DO NOT SCALE DRAWINGS. IF DIMENSIONS ARE OMITTED OR NOT CLEAR, CONTACT THE ARCHITECT OR STRUCTURAL ENGINEER OF RECORD FOR CLARIFICATIONS. THE CONTRACTOR SHALL COMPARE THE STRUCTURAL DRAWINGS WITH ARCHITECTURAL, PLUMPING, MECHANICAL, CIVIL AND ELECTRICAL DRAWINGS AS TO ALL LAYOUTS, DIMENSIONS AND ELEVATIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT FOR PROPER ADJUSTMENT BEFORE PROCEEDING WITH THE WORK. 3. SUBSTITUTION REQUESTS FOR MATERIALS SPECIFIED ON THE STRUCTURAL DRAWINGS MAY BE CONSIDERED WITH MATERIALS HAVING EQUIVALENT OR GREATER CAPACITY AND PERFORMANCE. CURRENT EVALUATION REPORTS AND PRODUCT INFORMATION SHALL BE PROVIDED TO THE STRUCTURAL ENGINEER DEMONSTRATING THE REQUIRED CAPACITY AND PERFORMANCE OF THE MATERIAL TO BE SUBSTITUTED. WRITTEN APPROVAL FROM THE E.O.R SHALL BE OBTAINED PRIOR TO THE SUBSTITUTION OF ANY MATERIAL SPECIFIED ON THE STRUCTURAL CONSTRUCTION DOCUMENTS. 4. ANY DEVIATION, MODIFICATION & SUBSTITUTION FROM THE APPROVED SET OF STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE OWNER'S REPRESENTATIVE FOR REVIEW/APPROVAL PRIOR TO ITS USE OR INCLUSION ON THE SHOP DRAWINGS & PRIOR TO PROCEEDING WITH THE WORK. 5. EXISTING CONDITIONS AS SHOWN ON THESE PLANS ARE FOR REFERENCE ONLY. CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL REPORT CONDITIONS THAT CONFLICT WITH THE CONTRACT DOCUMENTS TO THE OWNER'S REPRESENTATIVE. DO NOT DEVIATE FROM THE CONTRACT DOCUMENTS WITHOUT WRITTEN DIRECTION FROM THE OWNER'S REPRESENTATIVE. 6. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD IMPOSED UPON THE STRUCTURE. CONSTRUCTION LOADS SHALL NOT EXCEED THE DESIGN CAPACITY OF THE STRUCTURE AT THE TIME THE LOADS ARE IMPOSED. 7. SPECIFICATIONS RELATED TO WATERPROOFING, INCLUDING BUT NOT LIMITED TO MEMBRANES, WATERSTOPS, SEALANTS, FLASHING, VAPOR BARRIER, ARE AS SPECIFIED BY ARCHITECT/WATER PROOFING CONSULTANT. 8. FEATURES OF CONSTRUCTION SHOWN ARE TYPICAL AND SHALL APPLY GENERALLY THROUGHOUT SIMILAR CONDITIONS. ALL DETAILS REFERENCED, AND DETAILS NOT REFERENCED ON PLANS, SHALL BE CONSIDERED TYPICAL AND APPLY TO ALL SIMILAR CONDITIONS OF THE CONSTRUCTION. 9. UNLESS SHOWN OTHERWISE, DETAILS SHOWN ON "TYPICAL DETAIL" SHEETS SHALL BE USED WHEREVER APPLICABLE. SPECIFIC DETAILS ON THE STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER "TYPICAL DETAILS". SPECIFIC NOTES ON STRUCTURAL DRAWINGS TAKE PRECEDENCE OVER NOTES SHOWN IN "GENERAL NOTES". 10. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, UNLESS OTHERWISE SHOWN THEY DO NOT INDICATE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE CONSTRUCTION AND ALL ADJACENT PROPERTIES DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT ARE NOT LIMITED TO BRACING, SHORING OF LOADS DUE TO CONSTRUCTION EQUIPMENT, ETC. OBSERVATION VISITS TO THE SITE BY THE ARCHITECT OR E.O.R SHALL NOT INCLUDE OBSERVATION OF THE ABOVE ITEMS. 11. DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN MIXING CONCRETE SHALL CONFORM WITH ASTM C1602. CONCRETE MIX DESIGNS CONTAINING FLY ASH MAY BE USED WHERE CONCRETE IS NOT VISUALLY EXPOSED. FLY ASH SHALL CONFORM WITH ASTM C618 AND MAY REPLACE UP TO 20% PORTLAND CEMENT BY VOLUME. CONCRETE STRENGTH TEST REPORTS SHALL BE IN COMPLIANCE WITH ACI 318 AND SHALL BE SUBMITTED TO E.O.R. FOR REVIEW. ALL REINFORCING BARS, ANCHOR BOLTS AND ALL OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. 2. 3. 4. 5. 6. 7. 8. CONDITION COVER A.CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH 3" B.EXPOSED TO EARTH OR WEATHER (INCLUDING SLABS ON GRADE) #6 AND LARGER 2" #5 AND SMALLER 1 1/2" C.NOT EXPOSED TO WEATHER OR IN CONTACT WITH SOIL: 1.STRUCTURAL SLABS, WALLS w/ #11 BARS AND SMALLER 3/4" #14 BARS AND LARGER 1 1/2" 2. BEAMS, COLULMNS 1 1/2" DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, SIZE AND SPACING AS THE MAIN REINFORCING, UNO. CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC COATED WHEN RESTING ON EXPOSED SURFACES. 1. 2. 3. 4. 11. 12. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF SLAB SLOPES, DEPRESSIONS, CURBS, DRAINS, NON-STRUCTURAL PARTITIONS AND OTHER EMBEDDED ITEMS NOT SHOWN ON THE STRUCTURAL PLANS. ALL EXCAVATIONS SHALL BE PROPERLY BACKFILLED WITH NON-EXPANSIVE SOIL BUT NOT BEHIND RETAINING WALLS BEFORE CONCRETE OR MASONRY ATTAINS ITS FULL DESIGN STRENGTH. FOOTINGS SHALL BEAR ON NATIVE SOIL OR ENGINEERED FILL AS DIRECTED BY THE GEOTECHNICAL REPORT. THE GEOTECHNICAL INVESTIGATION REPORT AND ITS RECOMMENDATIONS SHALL BE FOLLOWED AND SHALL BE CONSIDERED MINIMUM REQUIREMENTS UNLESS MORE STRINGENT REQUIREMENTS ARE PRESENTED IN THE SPECIFICATIONS OR ON THE DRAWINGS. REMOVE LOOSE SOIL AND STANDING WATER FROM FOUNDATION EXCAVATIONS PRIOR TO PLACING CONCRETE. WHERE NEW CONCRETE IS PLACED AGAINST EXISTING CONCRETE, THE EXISTING CONCRETE SHALL BE ROUGHENED TO A MINIMUM 1/4" AMPLITUDE. ALUMINUM CONDUIT, ALUMINUM SLEEVES AND ALUMINUM EMBEDS ARE NOT PERMITTED IN CONCRETE. ALL CONDUITS SHALL BE PLACED WITHIN THE MIDDLE ONE-THIRD OF THE SLAB THICKNESS. THE MAXIMUM SIZE OF CONDUITS SHALL BE 1 1/4" DIAMETER AND SHALL BE SPACED NO CLOSER (TO EACH OTHER OR REINFORCING STEEL) THAN 4 INCHES UNLESS PRIOR APPROVAL IS OBTAINED FROM THE STRUCTURAL ENGINEER. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. ALL HOLDOWNS AND POST ANCHORS SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. 12. 13. 9. 106Ceiling DESIGN CRITERIA COEFFICIENT OF FRICTION - EQUIVALENT LATERAL FORCE PROCEDUREANALYSIS PROCEDURE 0.112WDESIGN BASE SHEAR, V WIND IMPORTANCE FACTOR, I 1.0 ANALYSIS PROCEDURE W ENCLOSED SYSTEM/ANALYTICAL ALL HEIGHT DESIGN METHODOLOGY GENERAL NOTES CONCRETE TYPICAL ABBREVIATIONS FOUNDATION TIME BETWEEN CONCRETE BATCHING AND PLACEMENT SHALL BE IN ACCORDANCE WITH ASTM C94. 10.CONCRETE PLACEMENT/CURING/REDUCTION IN STRENGTH SHALL CONFORM TO ACI 305R AND 3065R REQUIREMENTS FOR HOT AND COLD WEATHER CONCRETING. 11.CONCRETE SHALL BE CURED PER ACI 308R, UNLESS ALTERNATE METHODS OF CURING HAVE BEEN APPROVED BY THE ARCHITECT OR ENGINEER. FOR SLAB CURING, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING COMPATIBILITY OF CURING COMPOUNDS WITH PROPOSED FINISHES PRIOR TO COMMENCING ANY WORK. MAX. SLUMP SHALL BE 5 INCHES EXCEPT WHERE ADMIXTURES/PLACITIZERS HAVE BEEN ADDED IN THE MIX DESIGN TO IMPROVE FLOWABILITY/WORKABILITY. THE SLUMP LIMIT SHALL BE BASED ON ADMIXTURE MANUFACTURER'S RECOMMENDATIONS. REINFORCING STEEL LAP SPLICES OF BARS SHALL CONFORM TO THE TYPICAL THE LAP SCHEDULE ON THE PLANS, U.N.O. NO TACK WELDING OF BARS ALLOWED. 5. MECHANICAL SPLICE COUPLERS MAY BE USED AND SHALL HAVE CURRENT ICC APPROVAL AND BE CAPABLE OF DEVELOPING 125% OF THE BAR'S YIELD STRENGTH. 6. ALL REINFORCING BARS SHALL BE BENT COLD. DO NOT FIELD BEND OR UNBEND ANY BARS IN A MANNER THAT MAY DAMAGE REINFORCING. 7. REINFORCING SPACING SHOWN ON THE PLANS ARE THE MAXIMUM SPACING "ON CENTER SPACING". DO NOT EXCEED THIS. ANY DISCREPANCIES DURING CONSTRUCTION SHALL BE FORWARDED TO THE ENGINEER FOR REVIEW AND APPROVAL. 8. TYPICAL REINFORCING FOR CONCRETE SLAB ON METAL DECK SHALL BE 6x6-W1.4xW1.4 WELDED WIRE FABRIC, U.N.O. PLACE WWF MID-DEPTH OF THE SLAB OVER THE TOP OF THE FLUTE OF THE METAL DECK. 9. ALL DOWELS TO BE SET IN CONCRETE SHALL BE TIED IN PLACE PRIOR TO PLACEMENT OF CONCRETE. NO WET SETTING, STABBING, RODDING OR OTHER MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED DURING THE PLACEMENT OF CONCRETE. 10. 12. NAILING SCHEDULE, CONT. SHEET INDEX SHEET NO.SHEET TITLE S-0.10 GENERAL NOTES & REQUIREMENTS S-0.11 S-1.0 FOUNDATION & ROOF FRAMING PLAN SD1.0 FOUNDATION DETAILS SD2.0 STRUCTURAL DETAILS S-0.20 TYPICAL DETAILS GLB. GLUE-LAMINATED BEAM GR.BM.GRADE BEAM GWB. GYPSUM WALLBOARD HI. HIGH HDR. HEADER HFX HARDY FRAME HORIZ.HORIZONTAL K.P. KING POST LT.WT.LIGHT WEIGHT L.V.L. LAMINATED VENEER LUMBER MAS. MASONRY M.B. MACHINE BOLT (N) NEW N.G. NATURAL GRADE O/C ON CENTER P.J. POUR JOINT PSL. PARALLAM BEAM PLWD.PLYWOOD P.T. PRESSURE TREATED REINF.REINFORCING REQ'D REQUIRED RR. ROOF RAFTER T.O.B TOP OF BEAM UNO.UNLESS NOTED OTHERWISE V.I.F. VERIFY IN FIELD FLOOR 21. JOIST TO SILL, TOP PLATE OR GIRDER. 3-8d COMMON TOE NAIL 22. RIM JOIST, BAND JOIST OR BLOCKING TO SILL OR TOP PLATE 8d COMMON 6" o.c. TOE NAIL 23. 1"x6" SUBFLOOR OR LESS TO EACH JOIST. 3-8d COMMON FACE NAIL 24. 2" SUBFLOOR TO JOIST OR GIRDER.2-16d COMMON FACE NAIL 25. 2" PLANKS (PLANK & BEAM-FLOOR & ROOF). AT EACH BEARING, FACE NAIL. 26. BAND OR RIM JOIST TO JOIST.3-16d COMMON END NAIL 27. BUILT-UP GIRDERS AND BEAMS, 2-INCH LUMBER LAYERS. 10d COMMON 24" O.C. FACE NAIL AT TOP AND BOTTOM STAGGERED ON OPPSITE SIDES. AND: 3-10d COMMON FACE NAIL AT ENDS AND AT EACH SPLICE. 28. LEDGER STRIP SUPPORTING JOISTS OR RAFTERS. 3-16d COMMON END NAIL 29. BRIDGING OR BLOCKING TO JOIST. 2-8d COMMON EACH END, TOE NAIL A. NAILS ARE SMOOTH-COMMON, BOX OR DEFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. NAILS FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE MINIMUM AVERAGE BENDING YIELD STRENGTHS AS SHOWN: 90 ksi FOR SHANK DIAMETERS LARGER THAN 0.142 INCH BUT NOT LARGER THAN 0.177 INCH, AND 100 ksi FOR SHANK DIAMETERS OF 0.142 INCH OR LESS. B. NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS ARE 48 INCHES OR GREATER. C. FOUR-FOOT BY 8-FOOT OR 4-FOOT BY 9 FOOT PANELS SHALL BE APPLIED VERTICALLY. D. SPACING OF FASTENERS NOT INCLUDED IN THIS TABLE SHALL BE BASED ON CHAPTER 23. E. FOR WOOD STRUCTURAL PANEL ROOF SHEATHING ATTACHED TO GABLE END ROOF FRAMING AND TO INTERMEDIATE SUPPORTS WITHIN 48 INCHES OF ROOF EDGES AND RIDGES, NAILS SHALL BE SPACED AT 6 INCHES ON CENTER WHERE THE ULTIMATE DESIGN WIND SPEED IS LESS THAN 130 MPH AND SHALL BE SPACED 4 INCHES ON CENTER WHERE THE ULTIMATE DESIGN WIND SPEED IS 130 MPH OR GREATER BUT LESS THAN 140 MPH. F. GYPSUM SHEATHING SHALL CONFORM TO ASTM C1396 AND SHALL BE INSTALLED IN ACCORDANCE WITH GA 253. FIBERBOARD SHEATHING SHALL CONFORM TO ASTM C208. G. SPACING OF FASTENERS ON FLOOR SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND REQUIRED BLOCKING AND AT FLOOR PERIMETERS ONLY. SPACING OF FASTENERS ON ROOF SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING MEMBERS AND REQUIRED BLOCKING. BLOCKING OF ROOF OR FLOOR SHEATHING PANEL EDGES PERPENDICULAR TO THE FRAMING MEMBERS NEED NOT BE PROVIDED EXCEPT AS REQUIRED BY OTHER PROVISIONS OF THIS CODE. FLOOR PERIMETER SHALL BE SUPPORTED BY FRAMING MEMBERS OR SOLID BLOCKING. H.WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH THIS SCHEDULE, PROVIDE TWO TOE NAILS ON ONE SIDE OF THE RAFTER AND TOE NAILS FROM THE CEILING JOIST TO TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE. THE TOE NAIL ON THE OPPOSITE SIDE OF THE RAFTER SHALL NOT BE REQUIRED. I. RSRS-01 IS A ROOF SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667. 2-16d COMMON FOR NON-SHEAR WALL APPLICATIONS, ANCHOR BOLT SHALL BE INSTALL WITH ROUND WASHERS AND SHOULD CONFORM WITH ANSI/ASME B 18.22.1. USE MIN. 1 3/8" Ø X 7/64" THICK WASHER FOR 1/2" Ø BOLT, 1 3/4" Ø X 9/64" THICK WASHER FOR 5/8" Ø BOLT AND 2 1/2" Ø X 11/64" THICK WASHER FOR 1" Ø BOLT. U.N.O. NAIL SPACING TO BE NOT LESS THAN REQUIRED PENETRATION. EDGE AND END DISTANCES SHALL BE NOT LESS THAN HALF THIS SPACING. ALL SPACING AND EDGE AND END DISTANCES SHALL BE SUCH AS TO AVOID SPLITTING OF THE WOOD. HOLES FOR NAILS, WHERE NECESSARY TO PREVENT SPLITTING, SHALL BE BORED OF A DIAMETER SMALLER THAN THAT OF THE NAILS. ALL NAILS SHALL BE SINKER NAILS AND STAGGERED U.N.O., EXCEPT AS SHOWN IN NAILING SCHEDULE. STRUCTURAL GLUED-LAMINATED (GLULAM) TIMBER OF SOFTWOOD SPECIES SHALL BE IN CONFORMANCE WITH ANSI/AITC STANDARD A190.1 AND ASTM D3737, OR OTHER CODE APPROVED DESIGN, MANUFACTURING AND/OR QUALITY ASSURANCE PROCEDURES. MEMBERS SHALL BE MARKED WITH THE ENGINEERED WOOD SYSTEM APA EWS TRADEMARK INDICATING CONFORMANCE WITH THE MANUFACTURING, QUALITY ASSURANCE AND MARKING PROVISIONS OF ANSI/AITC STANDARD A190.1. THE MANUFACTURER OR SELLER SHALL SUBMIT CERTIFICATES OF CONFORMANCE TO THE FIELD INSPECTOR PRIOR TO INSTALLATION. ALL NON-STRUCTURAL ELEMENTS SHALL BE CONSTRUCTED PER APPROVED CODE REQUIREMENTS. FRAMING PLAN IS ONLY SHOWING FOR THE MAIN STRUCTURAL ELEMENTS IN ACCORDANCE WITH BUILDING CODE OR REQUIREMENTS ARE SPECIFIED OR REQUIRED BY THE LOCAL JURISDICTION. ALL CEILING JOISTS ARE TO BE 2x JOISTS. REFER TO FRAMING FOR ACTUAL SIZE AND SPACING. USE 5/8" DIA. X MIN. 12" ANCHOR BOLTS W/ MIN. 7" EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C. MAX. FOR SILL PLATE TO FOUNDATION UNLESS NOTED OTHERWISE ON SHEARWALL SCHEDULE. A BOLT BETWEEN 6" TO 12" FROM THE END OF EACH PIECE OF SILL (2 BOLTS MIN EACH PIECE). PIECE OF SILL SHALL BE CONSIDERED ENDED WHERE PLATE IS CUT OUT OVER ONE-THIRD OF CROSS SECTION. THE FOLLOWING BEAMS/HEADERS/RIMS CAN BE FROM ANY MANUFACTURER WITH CURRENT APPROVED ICC-ES EVALUATION REPORT WITH THE FOLLOWING MECHANICAL PROPERTIES: ALL WALLS SHALL BE CONSTRUCTED USING 2x STUDS @ 16" O.C. REFER TO FRAMING PLANS FOR ACTUAL STUD SIZE AND SPACING. TYPICAL UNBLOCKED DIAPHRAGM, UNO ON PLANS4. 5. HOT DIP GALVANIZED FASTENERS SUCH AS (BUT NOT LIMITED TO) NAILS, SCREWS, BOLTS, THREADED ROD, ETC., SHALL BE USED WHEN IN CONTACT WITH PRESERVATIVE OR FIRE RETARDANT TREATED LUMBER. EXCEPTION: PLAIN CARBON STEEL FASTENERS IN SBX/DOT AND ZINC BORATE PRESERVATIVE TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED. STUD WALLS PERPENDICULAR TO A CONCRETE OR MASONRY WALL SHALL BE BOLTED TO THE CONCRETE OR MASONRY WALL WITH 5/8" DIAMETER X 8" A307 BOLTS AT TOP, MID-HEIGHT AND BOTTOM. FRAMING MEMBER BEAMS/ POST/ RAFTERS & ALL OTHER STRUCTURAL FRAMING 2x FRAMING: #2 DF 4x FRAMING: #2 DF 6x FRAMING: #1 DF 8x FRAMING: #1 DF STUDS DFL STUD GRADE (UP TO 9'-0") DFL #2 (TALLER THAN 9'-0") TOP PLATES & MUD SILLS DFL CONSTRUCTION GRADE OR BETTER ALL STRUCTURAL WOOD SHALL BE OF DOUGLAS FIR LARCH SPECIES, (19% MAXIMUM MOISTURE CONTENT AT THE TIME OF CONSTRUCTION U.N.O.). FRAMING MEMBER BEAM/ HEADERS SIZE (WIDTH)Fb Fc perp F Fv Ft Ec parallel TYPE MATERIAL RIM BOARD 3 1/2" & WIDER 1 3/4" & 2 5/8" WIDE 1 1/4" THICK (MIN) 3100 PSI 2800 PSI 1750 PSI 750 PSI 525 PSI 285 PSI 285 PSI 225 PSI 2150 PSI 2150 PSI 1100 PSI 2.0E6 PSI 3000 PSI 2500 PSI (MIN) SPEC CAMBER CONDITION LVL LVL LVL 24F-V4 24F-V8 2400 PSI 1850 PSI Fb @ BOT @ TOP Fb Fv (MIN) E (MIN) 265 PSI 2.0E6 PSI 1.3E6 PSI 1.8E6 PSI1600' RADIUS, UNO SINGLE SPAN 2400 PSI 2400 PSI 265 PSI 1.8E6 PSI1600' RADIUS, UNO ALL OTHERS NAIL SIZE 8d COMMON 10d COMMON 16d COMMON 0.131"2 1/2" 0.148" 0.162" 3" 3 1/2" SPECIFICATION SAWN LUMBER1. STRUCTURAL COMPOSITE LUMBER2. GLUED LAMINATED LUMBER3. 750 PSI 3000 PSI SHANK DIAMETER LENGTH ROOF FLOOR SHEATHING APA RATED SHEATHING 15/32 PERFORMANCE CATEGORY 32/16 EXPOSURE 1 NAILING 8d's @ 6" B.N. 8d's @ 6" E.N. 8d's @ 12" F.N. APA RATED STURD-I-FLOOR 19/32 PERFORMANCE CATEGORY 20" OC EXPOSURE 1 10d's @ 6" B.N. 10d's @ 6" E.N. 10d's @ 12" F.N. USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE USED: GRABBER PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE QUICK DRIVE SCREWS (ICC-ER-1472) FOR SHEAR WALL APPLICATIONS, ANCHOR BOLT SHALL BE INSTALLED WITH PLATE WASHERS OF MIN. 3" SQ. X 0.229" THICK BETWEEN SILL PLATE AND NUT. EDGE(S) OF PLATE WASHERS SHALL BE 1/2" MAX. FROM INSIDE FACE OF SHEAR PANEL. ALL METAL FRAMING CONNECTORS SHALL BE MANUFACTURED BY SIMPSON STRONG TIE COMPANY (CURRENT CATALOG), OR "USP" WITH EQUIVALENT ICC PUBLISHED VALUES AND SHALL BE INSTALLED PER SPECIFICATIONS, NO EXCEPTIONS. 1. 2. 3. 4. SILL PLATE SHALL BE PRESSURE-TREATED AND UNDER SHEAR WALLS OF UP TO 4'-0" IN LENGTH MUST BE CONTINUOUS. 6. 7. 8. 10. STUD BEARING WALLS AND PARTITIONS SHALL HAVE HAVE DOUBLE TOP PLATES LAPPED AT WALL AND PARTITION INTERSECTIONS. JOINTS IN UPPER AND LOWER MEMBERS OF DOUBLE TOP PLATES SHALL BE STAGGERED AT LEAST 4'-0". HOLES IN WOOD MEMBERS FOR BOLTS SHALL BE THE NOMIAL BOLT DIAMETER PLUS 1/16". LAG SCREWS SHALL BE TURNED, NOT DRIVEN, INTO PRE DRILLED HOLES. HOLES IN WOOD FOR LAG SCREW SHANK SHALL BE BORED TO THE SAME DIAMETER AND DEPTH AS THE SHANK, AND FOR THE THREADED PORTION BORED WITH A BIT NOT LARGER THAN 40% TO 70% OF THE SHANK DIAMETER. I-JOISTS SHALL BE MANUFACTURED BY WEYERHAEUSER OR EQUIVALENT APPROVED ICC MANUFACTURED PRODUCT. 9. WOOD COLUMNS SHALL HAVE SOLID VERTICAL BLOCKING THROUGH THE FLOORS TO THE SUPPORT BELOW. FOR WALLS 10'-0" AND GREATER PROVIDE BLOCKING AT MID-HEIGHT FOR CONSTRUCTION STABILITY. ALL WALLS SHALL HAVE SINGLE BOTTOM PLATE AND DOUBLE TOP PLATE, UNO. ALL EXTERIOR LUMBER AND ALL LUMBER IN CONTACT WITH CONRETE OR MASONRY, OR EXPOSED TO THE EXTERIOR SHALL BE TREATED LUMBER. DO NOT CUT, BORE, COUNTERSINK OR NOTCH WOOD MEMBERS EXCEPT WHERE SHOWN IN THE DETAILS. PROVIDE DOUBLE JOISTS BENEATH ALL PARALLEL WALLS AND SOLID BLOCKING BENEATH ALL WALLS PERPENDICULAR TO JOISTS. WOOD NAILERS: UNO. ON PLANS AND DETAILS, WHERE WOOD MEMBERS ARE TO BE CONNECTED TO STEEL ELEMENTS, OR WHERE WOOD NAILERS CONNECTED TO STEEL MEMBERS ARE NEEDED FOR PROPER INSTALLATION OF FINISH MATERIALS, AS A MINIMUM PROVIDE WOOD NAILERS AS SPECIFIED BELOW WITH 5/8"Ø WELDED THREADED STUDS @ 24" O.C.: A. WOOD NAILERS NEEDED ONLY FOR INSTALLATION OF FINISH MATERIAL: 2X WOOD NAILERS, COUNTERSINKING OF THREADED STUDS BOLT IS ACCEPTABLE IF NEEDED FOR FLUSH INSTALLATION OF FINISH MATERIAL. B. WOOD NAILERS NEEDED TO SUPPORT OTHER WOOD ELEMENTS: 2X OR 3X WOOD NAILERS WITH OR WITHOUT COUNTERSINKING OF THREADED STUDS BOLT RESPECTIVELY. 1. 2. 3. 4. 5. 6. 7. 8. 9. 12. 10. 13. 14. WOOD SCREWS SHALL BE TURNED, NOT DRIVEN, INTO LEAD HOLES. SOAP OR OTHER LUBRICANTS SHALL BE PERMITTED AS NEEDED TO FACILITATE THE INSERTION AND PREVENT DAMAGE OF THE WOOD SCREW. LEAD SCREWS SHALL BE ABOUT 7/8 THE DIAMETER OF THE SCREW. THE MINIMUM PENETRATION OF WOOD SCREWS SHALL BE 10 TIMES THE SCREW DIAMETER OR 1.5", WHICHEVER IS GREATER. PENETRACTION IS MEASURED INTO THE PIECE RECEIVING THE NAIL POINT. 15. 11. 16. 17. NAILING & HARDWARE WOOD FRAMING WOOD (MIN)(MIN)(MIN)(MIN)(MIN) WOOD FRAMING, CONT. ALL WOOD CONSTRUCTION CONNECTORS SHOWN ON THE PLANS OR DETAILS SHALL BE SIMPSON STRONG-TIE OR EQUIVALENT, U.N.O. ALL CONNECTORS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS IN CONJUNCTION WITH APPROVED ICC REPORTS. NOTIFY EOR FOR ANY POTENTIAL SUBSTITUTION PRIOR TO COMMENCING WORK. 18. - ALL SHEATHING SHALL BE LAID WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, SHALL BE C-D OR C-C SHEATHING CONFORMING TO CBC 2303.1.5. SDS SCREWS SPECIFIED ON PLANS SHALL BE MANUFACTURED BY SIMPSON STRONG-TIE WITH ICC ESR-2236. ALTERNATES MAYBE USED ONLY WITH PRIOR APPROVAL BY EOR. 19. 1. BLOCKING BETWEEN CEILING JOISTS OR RAFTERS TO TOP PLATE 2. CEILING JOISTS TO PLATE 3. CEILING JOIST NOT ATTACHED TO PARALLEL RAFTER, LAPS OVER PARTITION 4. CEILING JOIST ATTACHED TO PARALLEL RAFTER 5. COLLAR TIE TO RAFTER, FACE NAIL OR 1 1/4"X20 GA.RIDGE STRAP TO RAFTER 6. RAFTER OR ROOF TRUSS PLATE 7. ROOF RAFTER TO RIDGE, VALLEY OR HIP RAFTERS OR ROOF RAFTER TO MINIMUM 2" RIDGE BEAM 3-8d COMMON 3-16d COMMON PER TABLE 2308.7.3.1 DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF FASTENER TOE NAIL FACE NAIL FACE NAIL EACH RAFTER (2) TOE NAILS ON ONE SIDE AND (1) TOE NAIL ON OPP. SIDE OF EACH RAFTER OR TRUSS 3-8d COMMON PER JOIST, TOE NAIL 3-10d COMMON FACE NAIL 3-10d COMMON 3-10d COMMON TOE NAIL SPACING AND LOCATION ROOF WALL 8. STUD TO STUD(NOT AT BRACED WALL PANELS)16d COMMON 24" o.c. FACE NAIL 9. STUD TO STUD AND ABUTTING STUDS AT INTERSECTING WALL CORNERS ( AT BRACED WALL PANELS) 16" o.c. FACE NAIL16d COMMON 10. BUILT-UP HEADER( 2" TO 2" HEADER WITH 1/2" SPACER)16d COMMON 16" o.c. FACE NAIL 11. CONTINUOUS HEADER TO STUD 4-8d COMMON TOE NAIL 12. TOP PLATE TO TOP PLATE 16d COMMON 16" o.c. FACE NAIL 13. DOUBLE TOP PLATE SPLICE 8-16d COMMON FACE NAIL ON EA. SIDE OF END JOINT (MINIMUM 24" LAP SPLICE LENGTH EA. SIDE OF END JOINT) 14. BOTTOM PLATE TO JOIST, RIM JOIST,BAND JOIST OR BLOCKING(NOT AT BRACED WALL PANELS) 16d COMMON 15. BOTTOM PLATE TO JOIST, RIM JOIST,BAND JOIST OR BLOCKING(AT BRACED WALL PANELS) 2-16d COMMON 20. 1"x8" AND WIDER SHEATHING TO EACH BEARING.FACE NAIL 19. 1"x 6" SHEATHING TO EACH BEARING.2-8d COMMON FACE NAIL 18. 1" BRACE TO EACH STUD AND PLATE.2-8d COMMON FACE NAIL 17. TOP PLATES, LAPS AT CORNERS AND INTERSECTIONS.2-16d COMMON FACE NAIL 16. TOP OR BOTTOM PLATE TO STUD.4-8d COMMON NAILING SCHEDULE END NAIL 2-8d COMMON 16" o.c. FACE NAIL 16" o.c. FACE NAIL REDUNDANCY FACTOR, 1.3 GENERAL NOTES & REQUIREMENTS MAX. STUD HEIGHT SPACING (FEET)(INCHES) USE THIS SPAN TABLE FOR STUD SPACING (U.N.O. ON PLANS):20. ONE FLOOF ONLY (INCHES) TWO FLOOF ROOF & CLN'G (INCHES) ONE FLOOF ROOF & CLN'G ROOF & CLN'G ONLY (INCHES)(INCHES) STUD HEIGHT STUD SIZE 24 MAXIMUM SPACING WHEN SUPPORTING NON-BEARING WALLSBEARING WALLS SIZE, HEIGHT AND SPACING OF WOOD STUDS 24 24 - - 14 14 20 - - 24 24 24 - - NOT ALLOWED 16 16 16 24 16 24 24 - - 24 24 24 - - 10 10 2x4 10 10 10 3x4 2x6 2-2x4 2-2x6 - NO MULTIPLES OF 2X4"S ARE ALLOWED TO SPAN MORE THAN 14'-0". BEARING WALLS EXCEEDING 10'-0" MUST BE DESIGNED CASE BY CASE. * SHALL NOT BE USED IN EXTERIOR WALLS. * REFER TO PLANS FOR STUD HEIGHTS EXEEDING THIS TABLE. FOR INTERIOR NON-SHEAR WALLS USE SIMPSON 0.157"Ø SERIES PDPAWL SHOT PINS WITH A PENETRATION OF 3/4" INTO SLAB AT 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138. ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING BARS/STEEL ARE TO THE CENTER OF STEEL U.N.O. ON THE PLANS OR DETAILS: S-0.12 SOIL REPORT S-0.13 SOIL REPORT S-0.14 SOIL REPORT 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/27/2023 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/27/2023 GE N E R A L N O T E S & RE Q U I R E M E N T S S-0.10 1402 W 10th St & Unit #2 - 101117923-245/8/2024 PREFABRICATED OR SPECIALTY ITEMS AND THEIR COMPONENTS, WHICH ARE INDICATED BY THE STRUCTURAL DRAWINGS TO BE DESIGNED BY OTHERS, MAY BE SUBMITTED TO THE ARCHITECT AND/OR ENGINEER OF RECORD FOR REVIEW AS A DEFERRED SUBMITTAL PROVIDED THAT SUCH SUBMITTAL IS AUTHORIZED BY THE BUILDING DEPARTMENT. DEFERRED SUBMITTALS REQUIRED TO BE SUBMITTED TO THE STRUCTRURAL ENGINEER OF RECORD SHALL INCLUDE BUT NOT BE LIMITED TO: A. MECHANICAL, ELECTRICAL AND PLUMPING EQUIPMENT B. SELF SUPPORTING, PRE-MANUFACTURED STAIR ASSEMBLY C. PREFABRICATED ROOF & FLOOR TRUSSES D. HVAC STRUCTURAL SUPPORT REQUIREMENTS E. AWNINGS, SIGNAGE, FASCIAS, ETC. F. FIRE SPRINKLERS G. CONTINUOUS TIE DOWN SYSTEM H. CONCRETE MIX DESIGN CONTINUOUS AND PERIODIC SPECIAL INSPECTION IS REQUIRED FOR THE WORK AS DESCRIBED IN IBC/CBC CHAPTER 17, SEE INSPECTION SCHEDULE BELOW, ONLY CHECKED ITEMS ARE REQUIRED. APPROVAL BY THE INSPECTOR DOES NOT MEAN APPROVAL OF FAILURE TO COMPLY WITH THE PLANS OR SPECIFICATIONS, ANY DETAIL THAT FAILS TO BE CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO THE STRUCTURAL ENGINEER FOR INTERPRETATION OR CLARIFICATION. CONTINUOUS SPECIAL INSPECTION PER AWS D1.1 IS REQUIRED FOR ALL STRUCTURAL STEEL WELDING, EXCEPT FOR SINGLE PASS FILLET WELDS NOT EXCEEDING 5/16" IN SIZE. STRUCTURAL WOOD, PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEARWALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING OF COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM, INCLUDING WOOD SHEARWALLS, WOOD DIAPHRAGMS, DRAG STRUTS, BRACES, SHEAR PANELS, AND HOLD-DOWNS, EXCEPTION: SPECIAL INSPECTION IS NOT REQUIRED FOR WOOD SHEARWALLS, SHEAR PANELS AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING AND OTHER FASTENING TO OTHER COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM, WHERE THE FASTENER SPACING OF THE SHEATHING IS MORE THAN 4 INCHES ON CENTER. INSPECTIONS SHALL BE PERFORMED BEFORE COVERING. 1. 1. SHOP DRAWINGS SHALL BE SUBMITTED FOR ALL STRUCTURAL ITEMS. SHOP DRAWINGS ARE REVIEWED ONLY FOR GENERAL COMPLIANCE WITH THE STRUCTURAL DRAWINGS. DESIGN ACCURACY OF SUCH PRODUCT, DIMENSIONS AND QUANTITY OF THE PRODUCT IS NOT REVIEWED BY EOR. RESPONSIBILITY FOR CORRECTNESS SHALL REST WITH THE CONTRACTOR. ANY CHANGES, SUBSTITUTIONS, OR DEVIATIONS FROM CONTRACT DRAWINGS SHALL BE CLOUDED ANY OF THE AFOREMENTIONED SHALL NOT BE CONSIDERED APPROVED AFTER ENGINEER'S REVIEW UNLESS SPECIFICALLY NOTED ACCORDINGLY. 3. THE SHOP DRAWINGS DO NOT SUPERSEDE OR REPLACE THE ORIGINAL CONTRACT DRAWINGS. ANY ENGINEERING PROVIDED BY OTHERS AND SUBMITTED FOR REVIEW SHALL BEAR THE SEAL OF AN APPROPRIATELY REGISTERED ENGINEER. ENGINEERING SYSTEM SOLUTIONS SHALL NOT BE RESPONSIBLE FOR THE ADEQUACY OF ENGINEERING DESIGNS PERFORMED BY OTHERS. 4. SHOP DRAWINGS SHALL REFERENCE DATE AND DELTA (IF ANY) OF CONTRACT DRAWINGS.5. ALL DEFERRED SUBMITTALS SHALL INCLUDE CALCULATIONS AND DRAWINGS PREPARED IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES AND STAMPED BY AN APPROPRIATELY LICENSED PROFESSIONAL ENGINEER. SUBMITTALS SHALL SHOW LOCATION AND MAGNITUDE OF LOADS, SIZE AND CONFIGURATIONS OF MEMBERS, AND COMPATIBILITY WITH THE PRIMARY STRUCTURAL SYSTEM. 2. CONTRACTOR RESPONSIBLE FOR CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/COMPONENT LISTED IN THIS STATEMENT OF SPECIAL INSPECTION SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH A SYSTEM OR COMPONENT PER SEC 1704.4. WHERE FABRICATION OF MEMBERS AND ASSEMBLIES IS PERFORMED ON THE PREMISES OF A FABRICATOR'S SHOP, SPECIAL INSPECTION OF THE FABRICATED ITEMS SHALL BE REQUIRED BY THIS SECTION, UNLESS THE FABRICATOR IS REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION, APPROVAL SHALL BE BASED UPON REVIEW OF THE FABRICATOR'S WRITTEN PROCEDURAL AND QUALITY CONTROL MANUALS AND PERIODIC AUDITING OF FABRICATION PRACTICES BY AN APPROVED SPECIAL INSPECTION AGENCY, AT COMPLETION OF FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE BUILDING OFFICIAL STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. CONTRACTOR SHALL BE RESPONSIBLE OF VERIFYING APPROVAL OF FABRICATOR. 2. 3. 4. 5. 6. SUBMITTALS AND SHOP DRAWINGS STATEMENT OF SPECIAL INSPECTION: THE SPECIAL INSPECTOR SHALL BE A QUALIFIED INDIVIDUAL WHO WILL DEMONSTRATE COMPETENCE, AND KNOWLEDGE TO THE BUILDING OFFICIAL, FOR THE SPECIFIC TYPE OF SPECIAL INSPECTION REQUIREMENT REQUIRED PER SCHEDULE BELOW. 7. WOOD SPECIAL INSPECTIONS SHALL BE PER CBC SECTION 1705.5.8. SPECIAL INSPECTIONS FOR WIND AND SEISMIC RESISTANCE SHALL BE PER SECTION 1705.11 AND 1705.12 RESPECTIVELY. 9. REQ'D(?) STATEMENT OF SPECIAL INSPECTIONS (ONLY INDICATED ITEMS ARE REQUIRED) INSPECTION ITEMS SPECIAL INSPECTIORS (NAME, PHONE#, REGISTRATION#) STRUCTURAL STEEL (1705.2.1) STEEL FRAME JOINT DETAILS COLD-FORMED STEEL DECK (1705.2.2) OPEN-WEB STEEL JOISTS AND JOISTS GIRDERS (1705.2.3) REINFORCING STEEL AND PRE-STRESSING STEEL TENDONS SHOTCRETE (CURING TEMPERATURE, DESIGN MIX, PLACEMENT, STRENGTH ETC. PER TABLE 1705.3) COLD-FORMED STEEL TRUSSES SPANNING >= 60 FT CONCRETE CONSTRUCTION (DESIGN MIX, FORMWORK, PLACEMENT, ETC. PER TABLE 1705.3) (SEE 1705.3 EXCEPTIONS) STRUCTURAL WELDING/REBAR WELDING ALL MASONRY CONSTRUCTION (1705.4) WOOD FOR HIGH LOAD DIAPHRAGMS (1705.5.1) METAL-PLATE-CONNECTED WOOD TRUSSES SPANNING >=60 FT SOILS (EXCAVATION, FILL, ETC. PER 1705.6) (SEE 1705.6 EXCEPTIONS) DRIVEN PILES PER 1705.7 CAST IN PLACE PILES PER 1705.8 HELICAL PILE FOUNDATIONS PER 1705.9 ERECTION OF PRE- CAST CONCRETE MEMBERS BOLTS INSTALLED IN CONCRETE HIGH STRENGTH BOLTING/MATERIAL VERIFICATION WOOD DIAPHRAGM AND SHEAR WALLS* *: FOR SPECIAL INSPECTION OF WOOD DIAPHRAGMS AND SHEAR WALLS, CONTACT EOR FOR SCHEDULE. EPOXY/ POST INSTALLED ANCHORS YES YES YES 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/27/2023 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/27/2023 GE N E R A L N O T E S & RE Q U I R E M E N T S S-0.11 1402 W 10th St & Unit #2 - 101117923-245/8/2024 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/27/2023 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 6 S-0.20 TY P I C A L D E T A I L S EXTERIOR SHEATHING SEE ARCH. FOR INSULATION AND MEMBRANE STEEL ANGLE SCHEDULE SIZE SPAN MAX. L4x3 1/2x3/8 L6x3 1/2x1/2 L7x4x5/8 8'-0" 14'-0" 16'-0" ADD 9 GAUGE WIRE JOINT REINF. @24" O.C. VERTICAL FOR BUILDING IN SEISMIC DESIGN CATEGORIES C, D, E, F. FERO PAC-TIE WITH 2-#6 x 2" DECK SCREW AND WASHERS AS FOLLOWS: - TYPICAL AT 16" HORIZONTAL AND AT 24" VERTICAL - AROUND OPENINGS AT 12" HORIZONTAL AND AT 16" VERTICAL - NOT MORE THAN 12" FROM EDGE OF OPENINGS. - LOCATE ROW OF TIES MAX 12" ABOVE BEARING LEVEL AND 8" FROM TOP OF WALL. LLV STEEL ANGLE SUPPORT 3'-6" VENEER HEIGHT MAX AND NEED TO EXTENT AND BEAR ON EACH SIDE OF OPENING 4" MIN. SEE SCHEDULE FOR SIZE STUD WALL PER PLAN BEAM OR HEADER PER PLAN 1/2" DIA. LAG SCREW @12" O.C. WITH 2.5" MIN. EMBED TO BEAM OR HEADER OPENING VENEER TO WOOD WALL 4 2 3 5 6 TY P I C A L D E T A I L S 1 810 11 7 8 9 12 CONCRETE FLOOR CONDITION WOOD FLOOR CONDITION 1' MIN.PARTIAL SHEET AT WALL END ONLY 1' MI N . WH E R E RE Q ' D 7" MI N . STAGGER HORIZ. PANEL JOINTS, TYP OR USE FULL HEIGHT SHEETS WHERE POSSIBLE FULL SIZE PLYWOOD SHEET TYP. U.O.N. END POST AT HD EDGE NAIL TO HOLD DOWN END POST ANCHOR BOLTS PER SHEAR WALL SCHEDULE EDGE NAIL TO SILL BLK'G AT PANEL EDGES SAME SIZE AS PANEL EDGE STUD WITH STAGG. E.N. FIELD NAILING @12" O.C. EDGE NAIL AT PANEL EDGES TYP. STUDS PLYWOOD FACE GRAIN PARALLEL TO STUD EDGE NAIL TO SOLE PLATE SOLE PLATE NAILING A35 PER SHEAR WALL SCHEDULENOTES: 1.PROVIDE STAGGERED NAILING AT ALL PANEL EDGES. 2. STUDS ARE SPACED @ 16" O.C. MAX. U.O.N. 3. PROVIDE 1/8" GAP BETWEEN ADJACENT PANELS. EDGE NAIL TO TOP PLATES STAGGER NAILS EDGE NAIL AT ALL VERTICAL PANEL SPLICES (STAGG.). POST SIZE AT SPLICE PER SHEAR WALL SCHEDULE NOTES. SHEAR WALL FRAMING ELEVATION 1/ 2 " GA P FLOOR LINE H TOP OF PARTITION PARALLEL TO JOISTS 1/ 2 " GA P FLOOR LINE H TOP OF PARTITION PERPENDICULAR TO JOISTS 1/2 "GAP TOP OF PARTITION TO CONC. SLAB 1/ 2 " GA P 4x W/ 1/2" Ø HILTI KH-EZ @48" O.C. W/ 5" EMBED EA SIDE DBL. TOP PLATES CEILING WHERE OCCURS SLAB PER PLAN 2-16d TOE NAIL 2x4 FLAT @ 48" O.C. DBL. TOP PLATES 2x6 BRACING W/ (3)16d EA END @ 8'-0" WHERE WALL IS: 2x4 AND H> 14'-0" 2X6 AND H> 22'-0" PROVIDE 2x6 CONT. @ MIDSPAN WHERE BRACE EXCEEDS 6'-0" W/(2) 16dCEILING WHERE OCCURS SIMPSON DTC (SLOT VERTICAL) AT EA JOIST OR RAFTER DBL. TOP PLATES CEILING WHERE OCCURS SIMPSON DTC (SLOT VERTICAL) CLIP @ EA RAFTER CEILING WHERE OCCURS SIMPSON STCT CLIP (SLOTS VERTICAL) WHERE REQUIRED @ EA RAFTER PARTITION WALL (NON-BEARING/ NON-SHEARWALL) FRAMING AT NON BEARING WALLS NON BEARING WALLS FLOOR JOIST PER PLAN SIMPSON Z CLIP EA. END 2X BLOCKING @16" O.C. SIMPSON Z CLIP EA. END 2X BLOCKING @16" O.C. WALL PARALLEL TO JOIST WALL PERPENDICULAR TO JOIST NON BEARING WALLS PROVIDE DOUBLE JOISTS UNDER NON BEARING WALLS NON BEARING WALLS PROVIDE FULL HEIGHT BLK'G UNDER NON BEARING WALLS 2x SAWN LUMBER 1 3/4" ENGINEERED LUMBER WEB STIFFENER WALL PARALLEL TO JOIST OPTION NOTES: 1. NAILS SHALL BE DRIVEN TIGHT BUT SHALL NOT FRACTURE SURFACE OF SHEATHING. 2. PLYWOOD OSB PIECES SHALL CONTAIN NOT LESS THAN 8 SQ. FT. NOR BE LESS THAN 2-0" WIDE. 3. MAXIMUM UNSUPPORTED SHEATHING TO BE 24". 4. FRAMING AT ADJOINING PANEL EDGE SHALL BE 3" NOMINAL OR WIDER AND NAILS AT ALL PANEL EDGES SHALL BE STAGG. WHERE PANEL EDGE NAILING IS SPECIFIED AT 2 1/2" 0.C. OR LESS. 5. ALL PANEL EDGES OF THE FLOOR SHEATHING SHALL HAVE APPROVED T AND G JOINTS OR SHALL BE SUPPORTED BY BLK'G. PER IBC/CBC TABLE 2304.8 (3) FOOTNOTE D. 6. DIAPHRAGM BOUNDARY SHALL BE SUPPORTED BY FRAMING MEMBERS WITH BOUNDARY NAILING. SECTION A-A PLAN 1/8" GAP 4'-0"x8-0" SHEETS, STAGG. AS SHOWN FIELD NAINILG SHEATHING EDGE NAILS 2x MIN. FRAMING DIRECTION OF FACE GRAIN PERPENDICULAR TO SUPPORT DISCONTINUOUS EDGE W/2x MIN. FRAMING BLK'G. CONT. EDGE W/2x MIN. BLK'G. AT BLOCKED DIAPHRAGM JOIST PER PLAN CONT. EDGE W/O BLK'G. @ UNBLK'G. DIAPHRAGMEDGE NAILING STAGG. AA PANEL JOINT ROOF OR FLOOR SHEATHING LAYOUT 4' - 0 " M A X 1" MIN PENETRATION SECTION OF DOUBLE JOISTS PLAN VIEW NOTES: SEE ARCHITECTURAL, PLUMBING, MECHANICAL AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF OPENING WOOD JOISTS PER PLAN SHEATHING PER PLAN MSTA30 W/2x BLOCK TYP. @ CORNER DOUBLE JOISTS TAIL JOIST HANGER PER PLAN EDGE NAILING COMMON NAILS @ 6" O.C. EACH FACE TOP AND BOTTOM WEB STIFFENER AT HANGER (I-JOIST ONLY) TYP. FLOOR AND ROOF OPENING 1. 1/2" 3D MAX. L/3 MIN. D MIN. D/ 4 MA X . 2" M I N 2" M I N D/ 5 MA X . D ℄ JOIST AND HOLE NOTE: 1. D = DEPTH OF JOIST OR BEAM D1= STUD WIDTH L = CLEAR SPAN 2. PERDRILL CORNERS OF NOTCHES 3. NOTCH MAY OCCUR TOP OR BOTTOM, NOT BOTH. 4. NOTCHES AND HOLES ARE NOT ALLOWED IN CANTILEVER PORTION OF JOISTS. 5. MAX. ALLOWED IS A COMBINATION OF TWO NOTCHES AND/OR HOLES IN L/3 SPAN. D/ 6 MA X . RAFTER, JOIST OR BEAM DRILLING HOLES AND NOTCHING OF THE JOIST ROOF TRUSSES OR RAFTER PER PLAN NOTE: - USE PRE-FAB. STEP-DOWN TRUSSES PERPENDICULAR TO ROOF TRUSSES IN-LIEU OF 2x JACK RAFTERS 2x4 OR 2X6 RAFTERS @ 24" O.C. MAX. MAX. SPAN: 2x4 = 4'-0" 2x6 = 8'-0" 2x VALLEY PLATE W/(3) 16d INTO EACH RAFTER OR TRUSS ADD 2x4 STRUT FROM JACK RAFTER TO RAFTER OR TRUSS BELOW TO LIMIT OVER FRAMING RAFTER SPAN 2x RIDGE BOARD W/ DEPTH GREATER THAN JACK RAFTER OVER FRAMING INTERSECTION w/ POST INTERSECTION w/o POST OUTSIDE CORNER w/ POST OUTSIDE CORNER w/o POST NOTE: SEE FRAMING PLAN FOR SHEAR WALL LOCATIONS, ORIENTATIONS AND SCHEDULE REFERENCES 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD PLYWOOD AT DOUBLE-SIDED WALL POST AT PER PLAN 16d @ 12" O.C. POST AT PER PLAN 2x OR 3x STUD AS REQ'D., TYP. PER S.W. SCHED. PLY. CONT. THRU WALL INTERSECTION ATDOUBLE-SIDED WALL 16d @ 12" O.C. FOR 2x STUD 20d @ 6" O.C. FOR 3x STUD DOUBLE 2x, MIN. 16d @ 12" O.C. SHEAR WALL/ INTERSECTION DOUBLE STUDS 16d @24" O.C. TYP. WALL INTERSECTION DOUBLE TOP PLATES SILL PLATE NOTE : WHERE NOTCH IS GREATER THAN 1" PROVIDE 10 GA STRAP W/ WIDTH SAME AS DBL TOP PL.TOP PL OF SHEAR WALLS SHALL NOT BE NOTCHED UNLESS SPECIFICALLY DETAILED. NOTE : WHERE DEPTH OF NOTCH "B" OS GREATER THAN D/5 PROVIDE ANCHOR BOLT EA SIDE OF NOTCH PER END REQUIREMENT. NO MORE THAN ONE NOTCH IS PERMITTED IN EVERY 12'-0" @ SHEAR WALL 5" MIN. 9" MAX. 5" MIN. 9" MAX. 5" MIN. 9" MAX. 2D MIN. D D/ 2 D/ 2 "B" 8" MAX @ SHEAR WALL "B " D/ 3 8) 16D SIDE OF NOTCH (4PL) 5" 3" MAX.5"NOTCH D/ 2 MA X . 2D MIN. D/ 3 D/ 2 D/ 2 D DRILLED HOLE END OF SILL PL END OF SILL PL PLATE NOTCH AT NON SHEAR WALL NON BEARING STUDS BEARING STUDS NOTES: 1. NOTCHING AND BORING SHOULD NOT OCCUR IN SAME STUD SECTION 2. NO MORE THAN TWO SUCCESSIVE DOUBLE STUDS MAY HAVE 60% MAX BORING HOLES 5/8" MIN. DISTANCE TYP. ALL STUD 5/8" MIN. DISTANCE TYP. ALL STUD 1-1/2" 1-1/2" 40% MAX. STUD WIDTH NOTCH 60% MAX. STUD WITH BORE NOTCH SCHEDULE 25% 40% 60% 7/8" 1-3/8" 2" 2 x 4 % OF STUDS NOTCH/BORE 1-3/4" 2-1/8" 4-1/4" 2 x 8 60% MAX. STUD WITH BORE STUD NOTCHING/BORING LIMITS 1-3/8" 2-1/8" 3-1/4" 2 x 6 POST SEE PLAN OR SOLID BLK'G. SEAT ON HEADER (2)2x TOP PL'S PROVIDE FULL WIDTH BLK'G. UNDER POST ABOVE JOIST SEE PLAN FOR DIRECTION POST SEE PLAN SIMP. A34 EACH SIDE 2x SOLE PL. PLYWOOD SHEATHING SEE PLAN BLOCKING AT POSTS/TRIMMERS13 NOTES: 1. INSTALL SOLE PLATE ANCHORAGE AS SHOWN AND AT SPACING INDICATED IN WOOD SHEARWALL BASE CONNECTION SCHEDULE. 2. STAGGER ANCHORS AT DOUBLE SIDE OF SHEARWALL SHEARWALL WHERE OCCURS SOLE PLATE ANCHORAGE PER SHEARWALL SCHEDULE 1/2" MAX. SHEARWALL WHERE OCCURS CONCRETE SLAB PLATE WASHER 0.229"x3"x3"- MIN. @SHEARWALL APPLICABLE NOTE 2@SHEARWALL APPLICABLE NOTE 2 WOOD SHEARWALL SILL PLATE ANCHORAGE 1/2" MAX. 14 SPLICE LENGTH OF REINFORCEMENT REBAR TENSION SPLICE LENGTH (PROVIDED MASONRY COVER, CLEAR BAR SPACING AND TRANSVERSE REINFORCEMENT ARE IN COMPLIANCE WITH ACI 530-13, SECTION 9.3.3.3 ) fy f'm 1500 3 4 5 6 7 8 9 SPLICE LENGTH IN INCHES 19 34 45 54 63 72 81 18 30 45 54 63 72 81 18 26 41 54 63 72 81 18 24 38 54 63 72 81 BAR SIZE (psl)(psl) 2000 2500 3000 60000 CLASS B REBAR TENSION SPLICE LENGTH (PROVIDED CONCRETE COVER, CLEAR BAR SPACING AND TRANSVERSE REINFORCEMENT ARE IN COMPLIANCE WITH ACI 318-19, CHAPTER 25) f'c 25 0 0 P S I NO R M A L WE I G H T CO N C R E T E 30 0 0 P S I NO R M A L WE I G H T CO N C R E T E LOCATION *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS Fy 40 60 40 60 40 60 40 60 3 4 5 6 7 8 9 10 11 SPLICE LENGTH IN INCHES 20 27 34 41 59 68 76 86 95 30 41 51 61 89 101 114 129 143 16 21 26 31 46 52 59 66 73 23 31 39 47 68 78 88 99 110 19 25 31 37 54 62 70 78 87 28 37 46 56 81 93 104 118 131 14 19 24 28 42 47 54 60 67 21 28 36 43 62 71 80 90 100 45 0 0 P S I NO R M A L WE I G H T CO N C R E T E *TOP BARS AND HORIZONTAL WALL STEEL OTHER BARS 40 60 40 60 17 22 28 33 49 55 63 70 78 25 33 42 50 73 83 94 105 117 13 17 22 26 37 43 48 54 60 19 26 32 38 56 64 72 81 90 15 12/27/2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 2022 CALIFORNIA BUILDING CODE (1), (3) (4) (2) (1) 870 (PLF) SHEAR ALLOWABLE 220 PANEL TYPE SHEAR 8 d's 10 d's @ 2" O.C. 8 d's @ 2" O.C. @ 3" O.C. 15/32" APA Structural I rated 3/8" APA rated 10 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 4" O.C. NAILING (COMMON) EDGE 8 d's@ 6" O.C. 3/8" APA rated rated3/8" APA SHEATHING 8 d's @ 12" O.C. @ 12" O.C.8 d's FIELD (COMMON) NAILING PERIODIC SPECIAL INSPECTION IS REQUIRED. (4) (2) (5) (6) USE CLIPS @ 6" O.C. ON SIMPSON STRONG WALL & HARDY FRAME (U.N.O.). SINKER 16d's CONNECTION SILL PLATE @ 4" O.C. @ 6" O.C. @ 3" O.C. @ 2" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. @ 6" O.C. @ 5" O.C. SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. PROVIDE 3" NOMINAL OR WIDER FRAMING AT ADJOINING PANEL EDGES WITH NAILS STAGGERED. USE SPACING PER SCHEDULE IF NUMBER OF FRAMING CLIPS ARE NOT SPECIFIED ON FRAMING PLANS. FRAMING CLIPS A35's, LS50's OR LTP4's (5), (6) 2 ROWS STAGG. @ 3" O.C. 1/4"Øx6" SCREWS SDS (8) 260 320 380 410 490 (7)ALLOWABLE SHEAR ARE FOR STUDS SPACED @ 24" O.C. MAX. (8)SHEATHING CONFORMS TO EITHER DOC PS 1 OR PS 2 STANDARDS. (9)NAILING @ 6" O.C. WHEN STUDS ARE SPACED @ 24" O.C. (9) (7) (7) (7) 3/8" APA rated 530 640 (7) (10)FOR DOUBLE SIDED SHEAR PANELS: (10)(10)(10) (10)(10)(10) (10)(10)(10) a. USE HALF THE SPACING OF SILL PLATE ANCHOR BOLTS FOR TYPES SW3, SW4 & SW5. c. SEE SHEAR TRANSFER DETAIL ON PLAN FOR FRAMING CLIP TYPES AND HALF THE SPACING, FOR TYPES SW3, SW4 & SW5. 5/8" Ø 2X A.B. SPC'G @ 24" O.C. @ 16" O.C. @ 8" O.C. @ 8" O.C. @ 6" O.C. 48" 42" 36" 24" 18" SHEAR WALL SCHEDULE (4) (2) (4) (2) (4) (2) (3)STUDS ARE SPACED @ 16" O.C. MAX. UNLESS NOTED OTHERWISE ON PLAN. b. USE ONLY 1/4"Øx6" SDS SCREWS IN SCHEDULE AND WITH HALF THE SPACING, FOR TYPES SW4 & SW5. SW1 SW2 SW3 SW4 SW5 ENTRY PORCH 60 SF CL O S E T CL O S E T BED 1 10FT CL'G BED 2 10FT CL'G BATH 1 10FT CL'G BATH 2 10FT CL'G HALLWAY LIVING 10FT CL'G KITCHEN 10FT CL'G 1 2 A B SW 2 8' - 0 " SW 2 8' - 0 " SW2 8'-0" SW1 8'-0" HD1 HD1 HD1 HD1 HD1 HD1 HD1HD1 P1 P1 P1 #2 P1 #3 P1 #1 1'-0" CF1,TYP. 1' - 0 " CF1,TYP. CB 6 6 CB 6 6 1 SD1.0 1 SD1.0 1 SD1.0 1 SD1.0 ST E P 8 SD1.0 8 SD1.0 5 SD1.0 5 SD1.0 2 SD1.0 TYP. 5" THICK CONVENTIONAL SLAB w/#4 @ 18" O.C. E.W. AND UNDERLAYMENT PER DETAIL 1/SD1.0 ST E P 8 SD1.0 3 SD1.0 3 SD1.0 4 SD1.0 4 SD1.0 4 SD1.0 4 SD1.0 1'-0" CF1,TYP. 1' - 0 " CF1,TYP. P1 #1 ENTRY PORCH 60 SF CL O S E T CL O S E T BED 1 10FT CL'G BED 2 10FT CL'G BATH 1 10FT CL'G BATH 2 10FT CL'G HALLWAY LIVING 10FT CL'G KITCHEN 10FT CL'G 4x6 HDR 4x6 HDR 4x6 HDR 4x 6 H D R 4x 6 H D R 4x 6 H D R 4x6 HDR 4x6 HDR 4x 6 H D R 4x 6 H D R 1 2 A B 1 4x10 RIDGE BM 4x 4 6x 6 6x 6 6x 8 DR B M 6 6x8 DR BM 6x 8 DR B M 4x 4 RR1 RR1 RR 1 RR 1 RR 1 4x4 K.P .4x 4 2 CAN T . 3 1 / 2 " x 9 1 / 2 " LVL H I P B M 3CAN T . 3 1 / 2 " x 9 1 / 2 " LVL H I P B M 4 CAN T . 3 1 / 2 " x 9 1 / 2 " LVL H I P B M SW 2 8' - 0 " SW 2 8' - 0 " SW2 8'-0" SW1 8'-0"4x 4 4x 4 4x4 4x4 4x4 4x4 4x 4 4x 4 CJ 1 4x6 CL'G BM CJ 1 CJ 1 CJ 1 CJ 1 CJ 1 CJ 1 K.P. 4x4 K.P . 4x 4 5 2x6 HIP B M 4 SD2.0 4 SD2.0 4 SD2.0 4 SD2.0 8 SD2.0 8 S-0.20 TYP. 9 SD2.0 9 SD2.0 9 SD2.0 K.P . 4x 4 9 SD2.0 9 SD2.0 5 SD2.0 9 SD2.0 5 SD2.0 4 SD2.0 6 SD2.0 HHRC44 HHRC44 9 SD2.0 9 SD2.0 9 SD2.0 9 SD2.0 2B SD2.0 2B SD2.0 5 2x6HIP B M 7 4x6 CL'G BM 2 CAN T . 3 1 / 2 " x 9 1 / 2 " LVL H I P B M 4x 4 4x 4 CJ1 4 SD2.0 4 SD2.0 8 SD2.0 8 SD2.08 SD2.0 4x 4K.P . 9 SD2.0 1B SD2.0 10B SD2.0 1B SD2.0 2B SD2.0 R. R . W / E . N . FRAMING NOTES 1.REFER TO SHEET S-0.10 FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.USP CONNECTORS CAN BE USED IN LIEU OF SIMPSON STRONG TIE IN THIS PROJECT. CONTACT E.O.R. FOR CONVERSION TABLE OR SUBMIT SHOP DRAWINGS TO E.O.R. FOR REVIEW AND APPROVAL. 4.ALL BEAM HANGERS SHALL BE SIMPSON HU HANGERS, UNO. ON PLAN OR DETAIL. 5.USE ST6224 STRAP FOR THE TOP PLATES SPLICE AT ALL FRAMING LEVELS (3B/SD2.0), UNO ON PLANS. 6.USE ST22 STRAP FOR LEDGER SPLICES, UNO. 7.USE (1)CS16 x 3'-0" STRAP AT RIM JOISTS SPLICE, U.N.O ON PLANS. 1¼” MIN. LVL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES. 8.HEADER AT NON-BEARING WALLS, USE 2x4 FOR OPENINGS UP TO 3'-0" MAX., (2)2x4 FOR OPENINGS UP TO 6'-0" MAX., 4x6 FOR OPENINGS UP TO 12'-0" MAX., (UNO). USE 4x4 FOR OPENINGS LESS THAN 16" AT BEARING WALLS WITHOUT POINT LOADS. 9.WOOD HEADER OR POSTS MADE UP OF 2 OR MORE 2X'S SHALL BE SPIKED TOGETHER PER THE NAILING SCHEDULE. 10.SHEARWALL PANEL TO BE NAILED TO ALL MULTIPLE STUDS RECEIVING HOLDOWNS AND DO NOT BREAK AT PERPENDICULAR WALL LOCATIONS, UNO. FRAMING SCHEDULE DENOTES POST OR TRIMMER AS NOTED LEGEND DENOTES SHEAR PANEL LENGTH DENOTES PANEL TYPE, REFER TO SHEARWALL SCHEDULE DENOTES BEAM NUMBER, REFER TO E.O.R. CALCULATIONS DENOTES DIRECTION OF FRAMING MEMBER PER FRAMING SCHEDULE DENOTES DETAIL SHEET NUMBER DENOTES KEY NOTE NUMBER DENOTES OVER FRAMING DENOTES POST OR TRIMMER FROM FLOOR ABOVE DENOTES DETAIL NUMBER DENOTES DROP BEAM OR HEADER PER PLAN DENOTES FLUSH BEAM PER PLAN FOOTING SCHEDULE FOUNDATION NOTES 1.REFER TO SHEET S-0.10 FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.TOP OF ALL EXTERIOR FOOTING, GRADE BEAM FOOTING, PAD FOOTING, OR FLAG POLE FOOTING TO BE MIN. 6" BELOW FINISH GRADE. 4.FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555. 5.FOR DOUBLE SHEAR PANEL TYPES SW3, SW4, SW5 USE MIN. 3X6 SILL PLATES U.N.O. DENOTES HOLDOWN PER SCHEDULE DENOTES PAD NUMBER PER SCHEDULE DENOTES SLAB STEP PER ARCH. (VERIFY PRIOR TO CONSTRUCTION) DENOTES FOOTING HOLDOWN SCHEDULE DENOTES PAD MARK MEMBER TYPE RR1 2 X 8 ROOF RAFTERS @ 16" O.C. PAD SIZESYMBOL 2'-0" SQ. x 24" THICK SYMBOL SIMPSON HOLDOWN USP HOLDOWN NOTES -HDU2 X X X X SDX DENOTES DRAG DIRECTION STEP REINFORCEMENT (3) #4 E.W. X X X X'-X" P1 HD1 X #X DENOTES PAD NUMBER IN CALCULATIONS X CJ1 2 X 6 CEILING JOISTS @ 16" O.C. DENOTES FRAMING ZONE DIVISION CF1 CONT. W=12", D=16"CONT. (2) #4 TOP & BOTTOM REFER TO DETAIL 9/SD1.0 X DENOTES SHEARWALL LINE IN CALCULATIONS FOUNDATION PLAN SCALE : 1/4" = 1'-0" 1 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 03/15/2024 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 03/15/2024 02 / 0 1 / 2 0 2 4 1S T P L A N C O R R E C T I O N 2 02 / 2 2 / 2 0 2 4 2N D P L A N C O R R E C T I O N S-1.0 FO U N D A T I O N & RO O F F R A M I N G P L A N SCALE : 1/4" = 1'-0" ROOF FRAMING PLAN ADU ADU (A D U ) 1402 W 10th St & Unit #2 - 101117923-245/8/2024 2022 CALIFORNIA BUILDING CODE (1), (3) (4) (2) (1) 870 (PLF) SHEAR ALLOWABLE 220 PANEL TYPE SHEAR 8 d's 10 d's @ 2" O.C. 8 d's @ 2" O.C. @ 3" O.C. 15/32" APA Structural I rated 3/8" APA rated 10 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 12" O.C. 8 d's @ 4" O.C. NAILING (COMMON) EDGE 8 d's@ 6" O.C. 3/8" APA rated rated3/8" APA SHEATHING 8 d's @ 12" O.C. @ 12" O.C.8 d's FIELD (COMMON) NAILING PERIODIC SPECIAL INSPECTION IS REQUIRED. (4) (2) (5) (6) USE CLIPS @ 6" O.C. ON SIMPSON STRONG WALL & HARDY FRAME (U.N.O.). SINKER 16d's CONNECTION SILL PLATE @ 4" O.C. @ 6" O.C. @ 3" O.C. @ 2" O.C. @ 16" O.C. @ 12" O.C. @ 8" O.C. @ 6" O.C. @ 5" O.C. SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. PROVIDE 3" NOMINAL OR WIDER FRAMING AT ADJOINING PANEL EDGES WITH NAILS STAGGERED. USE SPACING PER SCHEDULE IF NUMBER OF FRAMING CLIPS ARE NOT SPECIFIED ON FRAMING PLANS. FRAMING CLIPS A35's, LS50's OR LTP4's (5), (6) 2 ROWS STAGG. @ 3" O.C. 1/4"Øx6" SCREWS SDS (8) 260 320 380 410 490 (7)ALLOWABLE SHEAR ARE FOR STUDS SPACED @ 24" O.C. MAX. (8)SHEATHING CONFORMS TO EITHER DOC PS 1 OR PS 2 STANDARDS. (9)NAILING @ 6" O.C. WHEN STUDS ARE SPACED @ 24" O.C. (9) (7) (7) (7) 3/8" APA rated 530 640 (7) (10)FOR DOUBLE SIDED SHEAR PANELS: (10)(10)(10) (10)(10)(10) (10)(10)(10) a. USE HALF THE SPACING OF SILL PLATE ANCHOR BOLTS FOR TYPES SW3, SW4 & SW5. c. SEE SHEAR TRANSFER DETAIL ON PLAN FOR FRAMING CLIP TYPES AND HALF THE SPACING, FOR TYPES SW3, SW4 & SW5. 5/8" Ø 2X A.B. SPC'G @ 24" O.C. @ 16" O.C. @ 8" O.C. @ 8" O.C. @ 6" O.C. 48" 42" 36" 24" 18" SHEAR WALL SCHEDULE (4) (2) (4) (2) (4) (2) (3)STUDS ARE SPACED @ 16" O.C. MAX. UNLESS NOTED OTHERWISE ON PLAN. b. USE ONLY 1/4"Øx6" SDS SCREWS IN SCHEDULE AND WITH HALF THE SPACING, FOR TYPES SW4 & SW5. SW1 SW2 SW3 SW4 SW5 (E) BEDROOM (E) BEDROOM (E) BEDROOM (E) LIVING + DINING (E) KITCHEN (E) BATH 2 (E) BATH 1 (E) W.I.C (E) STORAGE (E) ENTRY PORCH DR Y E R WA S H E R (E) HEATPUMP UNIT TO BE LEGALIZEDTO BE LEGALIZED 1 SD1.0 1 SD1.0 1 SD1.0 11 SD1.0 11 SD1.0 11 SD1.0 5" THICK CONVENTIONAL SLAB W/#4 @ 18" O.C. E.W. AND UNDERLAYMENT PER DETAIL 1/SD1.0 EXISTING CONCRETE SLAB 1' - 0 " CF1, TYP. 2 2 2 (E) BEDROOM (E) BEDROOM (E) BEDROOM (E) LIVING + DINING (E) KITCHEN (E) BATH 2 (E) BATH 1 (E) W.I.C (E) STORAGE (E) ENTRY PORCH DR Y E R WA S H E R (E) HEATPUMP UNIT TO BE LEGALIZEDTO BE LEGALIZED (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E) HDR (E ) H D R (E ) H D R (N ) 4 x 6 H D R (E) HDR (E ) H D R (E) HDR(E) HDR(E) HDR (E ) H D R (E ) H D R (E ) H D R (E ) H D R SW1 ARND (E) DR BM (E) DR BM (E) DR BM (E ) D R B M 11 SD2.0 4 SD2.0 12 SD2.0 13 SD2.0 1 2 8 (N) 4x6 FL BM RR 2 2- 2 x 4 1A SD2.0 14 SD2.0 2 2- 2 x 4 1A SD2.0 FRAMING NOTES 1.REFER TO SHEET S-0.10 FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.USP CONNECTORS CAN BE USED IN LIEU OF SIMPSON STRONG TIE IN THIS PROJECT. CONTACT E.O.R. FOR CONVERSION TABLE OR SUBMIT SHOP DRAWINGS TO E.O.R. FOR REVIEW AND APPROVAL. 4.ALL BEAM HANGERS SHALL BE SIMPSON HU HANGERS, UNO. ON PLAN OR DETAIL. 5.USE ST6224 STRAP FOR THE TOP PLATES SPLICE AT ALL FRAMING LEVELS (3B/SD2.0), UNO ON PLANS. 6.USE ST22 STRAP FOR LEDGER SPLICES, UNO. 7.USE (1)CS16 x 3'-0" STRAP AT RIM JOISTS SPLICE, U.N.O ON PLANS. 1¼” MIN. LVL RIM JOISTS SHOULD BE USED AT ALL FLOOR FRAMING EDGES. 8.HEADER AT NON-BEARING WALLS, USE 2x4 FOR OPENINGS UP TO 3'-0" MAX., (2)2x4 FOR OPENINGS UP TO 6'-0" MAX., 4x6 FOR OPENINGS UP TO 12'-0" MAX., (UNO). USE 4x4 FOR OPENINGS LESS THAN 16" AT BEARING WALLS WITHOUT POINT LOADS. 9.WOOD HEADER OR POSTS MADE UP OF 2 OR MORE 2X'S SHALL BE SPIKED TOGETHER PER THE NAILING SCHEDULE. 10.SHEARWALL PANEL TO BE NAILED TO ALL MULTIPLE STUDS RECEIVING HOLDOWNS AND DO NOT BREAK AT PERPENDICULAR WALL LOCATIONS, UNO. FRAMING SCHEDULE LEGEND DENOTES SHEAR PANEL LENGTH DENOTES PANEL TYPE, REFER TO SHEARWALL SCHEDULE DENOTES DIRECTION OF FRAMING MEMBER PER FRAMING SCHEDULE DENOTES DETAIL SHEET NUMBER DENOTES DETAIL NUMBER DENOTES DROP BEAM OR HEADER PER PLAN FOOTING SCHEDULE FOUNDATION NOTES 1.REFER TO SHEET S-0.10 FOR MORE INFORMATION. 2.CONTRACTOR IS RESPONSIBLE FOR VERIFYING PREFABRICATED SHEAR WALLS AND MATCH TOP PLATE HEIGHT AND WALL WIDTH AND NOTIFY ENGINEER OF RECORD IF DIFFERENT THAN PLANS. 3.TOP OF ALL EXTERIOR FOOTING, GRADE BEAM FOOTING, PAD FOOTING, OR FLAG POLE FOOTING TO BE MIN. 6" BELOW FINISH GRADE. 4.FOR NON-SHEAR WALLS, MASA/MASAP MUDSILL ANCHORS CAN BE USED IN LIEU OF ANCHOR BOLTS WITH END DISTANCE OF 4" MIN. PER ESR #2555. 5.FOR DOUBLE SHEAR PANEL TYPES SW3, SW4, SW5 USE MIN. 3X6 SILL PLATES U.N.O. MARK MEMBER TYPE RR2 2 X 6 ROOF RAFTERS @ 16" O.C. PAD SIZESYMBOL X X SDX REINFORCEMENT X X'-X" X CF1 CONT. W=12", D=16"CONT. (2) #4 TOP & BOTTOM DENOTES NEW FOOTING DENOTES EXISTING FOOTING PARTIAL FOUNDATION PLAN SCALE : 1/4" = 1'-0" 1 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 03/15/2024 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 03/15/2024 02 / 0 1 / 2 0 2 4 1S T P L A N C O R R E C T I O N 2 02 / 2 2 / 2 0 2 4 2N D P L A N C O R R E C T I O N S-2.0 & R O O F F R A M I N G P L A N (M A I N H O U S E ) SCALE : 1/4" = 1'-0" PARTIAL ROOF FRAMING PLAN MAIN HOUSE PA R T I A L F O U N D A T I O N MAIN HOUSE 1 1402 W 10th St & Unit #2 - 101117923-245/8/2024 3 CONT. REBAR PER PLAN MIN. 15 MIL VAPOR BARRIER 2" SAND TOP OF NATURAL GRADE OR COMPACT FILL MIN. 6" OVERLAP (U.N.O.) "D " M I N . E M B E D M E N T PE R S C H E D U L E MI N . 7" PLYWOOD OR OSB PER PLAN EXTERIOR FINISH (SEE ARCHITECTURAL DETAILS FOR WATER RESISTANT BARRIER/WEEP SCREED) MI N . 8" INTERIOR FINISH 2x STUDS PER PLAN 2x PTDF SILL (USE 3x WHERE REQUIRED PER PLANS) w/ 5/8" DIA. ANCHOR BOLTS CONC. SLAB PER PLAN SLAB REINF. PER PLAN PER PLAN ALT.1 ALT.2 TOP OF NATURAL GRADE 3" CLR. COVERPOSSIBLE COLD JOINT SEE NOTE NOTES: 1.FOR TWO POUR CONSTRUCTION, SEE FOOTING COLD JOINT DE TAIL. 2.MAXIMUM WATER CEMENT RATIO FOR SLAB CONCRETE SHALL BE W/C=0.45. 3.EMBEDMENT DEPTH, "D" SHALL BE MEASURED FROM THE LOWEST ADJACENT GRADE. TYPICAL EXTERIOR FOOTING FOR DUAL POUR, 7" EMBED. INTO THE 1st POUR START FROM THE COLD JOINT 4" GRAVEL OR AS RECOMMENDED BY GEOTECHNICAL REPORT REBAR CONT. T&B (U.N.O.) PER PLAN CONC. SLAB PER PLAN TOP OF NATURAL GRADE OR COMPACT FILL D PE R P L A N 4" 2" M I N . (P E R A R C H . ) ISOLATE SLAB FROM STEM WALL (USE 1/2" FIBERBOARD MATERIAL) PORCH SLAB SLOPE TO DRAIN PER ARCH PLANS STUD BEYOND 3" CLR. COVER, TYP. W PER PLAN NOTE: SEE DETAIL 1/SD1.0 FOR ADDITIONAL INFORMATION NOT SHOWN. 8" M I N . HOUSE TO PORCH TIE BEAM PER PLAN (WHERE OCCUR) 6" MIN. 6" M I N . TOP OF NATURAL GRADE OR COMPACT FILL CENTERLINE OF POST AND PAD FOOTING POST IN WALL (USE COLUMN BASE IF INDICATED PER PLAN) PER PLAN CONC. SLAB PER PLANSLAB REINF. PER PLAN AT INTERIOR FOOTING AT EXTERIOR FOOTING CL DE P T H P E R P L A N CONT. BAR OF INTERIOR BEARING FTG. PAD REINF. PER PLAN 3" CLR. COVER, TYP. TOP OF NATURAL GRADE OR COMPACT FILL CENTERLINE OF POST AND PAD FOOTING SHALL BE ALIGNED POST IN WALL OR USE COLUMN BASE AT ISOLATED POST PER PLAN CONC. SLAB PER PLANSLAB REINF. PER PLAN AT SLAB-ON-GRADE CL DE P T H PE R P L A N PAD REINF. PER PLAN 3" CLR. COVER, TYP. TOP OF NATURAL GRADE OR COMPACT FILL 6" M I N . EXTERIOR FINISH MI N . 8" INTERIOR FINISH CONC. SLAB PER PLAN FINISH GRADE CENTERLINE OF POST AND PAD FOOTING SHALL BE ALIGNED CL PAD REINF. PER PLAN 3" CLR. COVER, TYP. CONT. BAR OF EXTERIOR BEARING FTG. DE P T H P E R P L A N SLAB REINF. PER PLAN POST IN WALL (USE COLUMN BASE IF INDICATED PER PLAN) PAD FOOTING WITHIN BUILDING PERIMETER PER PLAN 2 1 / 4 " 1-3/4" MIN. STANDOFF (SO) PER MANUF. de F F TO T A L R O D L E N G T H 2F MIN. SQUARE PAD SIZE PER SCHEDULE EXTERIOR CONDITION FINISH GRADE EXT. FTNG. REBAR PER PLAN CONC. SLAB & REINF. PER PLAN CENTERLINE OF A.B., POST & PAD FOOTING CL HOLDOWN PER PLAN TOP OF NATURAL GRADE OR COMPACT FILL 2 1 / 4 " 1-3/4" MIN. STANDOFF (SO) PER MANUF. de F F TO T A L R O D L E N G T H 2F MIN. SQUARE PAD SIZE PER SCHEDULE CONC. SLAB & REINF. PER PLAN CENTERLINE OF A.B., POST & PAD FOOTING CL HOLDOWN PER PLAN FTNG. REBAR PER PLAN ALT. EXTERIOR CURB CONDITION CL TO T A L R O D L E N G T H ALT. INTERIOR CURB CONDITION CL TO T A L R O D L E N G T H 1-3/4" MIN. SEE HOLDOWN MANUF. SPECS. FOR REQUIRED BOLT STANDOFF le SS T B E M B E D M E N T L E N G T H 3" CLR. COVER, TYP. PER PLAN FINISH GRADE FTG. REBAR PER PLAN CONC. SLAB & REINF. PER PLAN CENTERLINE OF A.B. & POST CL HOLDOWN PER PLAN 3" - 5 " (1)#4 BAR L=100" CENTERED AT SSTB PAB ANCHOR AT EXTERIOR FTG.PAB ANCHOR AT INTERIOR FTG.SB/SSTB ANCHOR BOLT HOLDOWN ANCHOR BOLT FOR MONOLITHIC CAST-IN-PLACE CONCRETE FOOTING PAB ANCHOR BOLT CURB CONDITION PAB ANCHOR BOLT HDU2 SLAB ON GRADE SSTB24 SB5/8x24 EMBEDMENT (de) TYPESLAB ON GRADE CURB/ STEMWALL SQUARE 45° 24 ANCHORBOLT (TYP.) OUTEREDGEOFCONCRETE(TYP.) 0° 135°/90°/45° 0° 45°45° 0° 135° 1.BOLTS SHALL BE SECURED IN PLACE PRIOR TO FOUNDATION POUR, U.O.N. 2.REFER TO MANUF. REQUIREMENTS, SPECIFICATIONS, AND APPLICABLE ICC-ESR REPORT. 3.POST TENSION CABLE MAY NOT BE COUNTED AS REQ'D HOLDOWN REBAR. 4.FOOTING TOP REBAR(S) MAY BE COUNTED AS REQ'D HOLDOWN REBAR(S). 5.HOLDOWNS MAY BE RAISED OFF MUD-SILL TO ACCOMMODATE MIS-LOCATED ANCHOR BY1-1/2" MAX. REFER TO MANUF. SPECS. 6.FOR ALL INFORMATION NOT SHOWN, REFER TO DETAIL1. 7.USE OF MULTIPLE WASHERS TO ACCOMPLISH TOTAL REQ'D THICKNESSIS NOT PER MITTED. 8.REBAR IS REQUIRED AT TOP OF STEM WALL FOUNDATION, BUT IS NOT REQUIRED FOR SLAB ON GRADE EDGE AND GARAGE CURB IF FOOTING WIDTH IS 12" OR GREATER. REFER TO MANUFACTURER FOR MIN. END DISTANCES. HOLDOWN SIMPSON TYPE CURB/ STEMWALL -SB5/8x24 -- 24 PLAN VIEW OF SB/SSTB PLACEMENT INCONCRETE ANCHOR ORIENTATION 24 NOTES: 9.CURB SHALL BE 6" WIDE AT HTT5 AND HDU5 AND 8" WIDE AT HDU8 AND BEYOND SIMPSON "SSTB" ANCHOR BOLT SIMPSON "SB" ANCHOR BOLT SIMPSON "PAB" PRE-ASSEMBLED ANCHOR BOLT CORNER INSTALLATION (INSTALL WITH ARROW ON TOP OF THE BOLT ORIENTED AS SHOWN) NON-CORNER INSTALLATION (BOLT MAY BE INSTALLED @ 45° TO 135° AS SHOWN) CORNER INSTALLATION (INSTALL WITH ARROW ON TOP OF THE BOLT ORIENTED AS SHOWN) PAD SIZE (2F) 3" #4 CONT. 3" #4 CONT. 3" CLR. COVER, TYP. 3" CLR. COVER, TYP. HDU4 SSTB24 SB5/8x24-SB5/8x24 -- 12" MIN. 12 " M I N . ±6 " DE P T H T O M A T C H BO T T O M O F F T G . 8" M I N . PE R A R C H . 2" 6" MIN. PER ARCH. (1) 4# CONT. #4 VERT. @18" O.C. AT CENTER WHERE H >18" ±6 " DE P T H T O M A T C H BO T T O M O F F T G . FINISH GRADE (2)#5-TOP &BOTT. CONT. EXTEND MIN. 24" TO THE CONNECTING FOOTING OR TERMINATE W/ STANDARD HOOK AT FAR SIDE. 12" MIN. 12 " M I N . 3" CLR. COVER, TYP.3" CLR. COVER, TYP.(2)#5-TOP &BOTT. CONT. EXTEND MIN. 24" TO THE CONNECTING FOOTING OR TERMINATE W/ STANDARD HOOK AT FAR SIDE. WITH CURB BELOW GRADE H TIE BEAM NON-BEARING INTERIOR WALL CONC. SLAB PER PLAN USE SIMPSON 0.157"Ø PDPAWL SHOT PINS @ 16" O.C. OR APPROVED EQUIVALENT FOR NON-SHEAR WALLS, ICC-ES ESR-2138 2x STUDS PER PLAN INTERIOR FINISH NOTE: SEE DETAIL 1/SD1.0 AND NAILING & HARDWARE NOTE 10/S0.10 FOR ADDITIONAL INFORMATION NOT SHOWN. COLUMN & SPANDREL TIE BEAM & JOIST STIRRUP 6d bNOT E 1 135° SPANDREL & BEAM SUPPLEMENTARY TIE CROSS TIE db dbdb db db D D D 6db 3" MIN . 6db FOR #3 THRU #5 CROSS TIE 6d b F O R # 3 ~ # 5 12 d b F O R # 6 ~ # 8 12 d b DETAILING DIMENSION DETAILING DIMENSION D = 6db FOR #3 THRU. #8 BARS D = 8db FOR #9 THRU #11 BARS D = 10DB FOR #14 AND #18 BARS BEND BAR DIAMETER, D ALT. CROSS TIE END IN ALL CASES 6d b NOTE 1: BUT NOT LESS THAN 3" (SEISMIC HOOK) 90° STANDARD HOOK 180° STANDARD HOOK 6db 3" MIN . D D 2 1/2" MIN. BAR BENDING & STANDARD HOOKS STD. HOOK MI N . L A P 48 d b TYP. CONT. FTG. REBAR 0" 0" STD. HOOK TYP. CONT. FTG. REBAR 0" 0" 0" 0" MI N . L A P 4 8 d b MIN. LAP 48db T CONDITION CORNER CONDITION REINF. DETAILS AT FOOTING JUNCTIONS 8" M I N . SIMPSON COLUMN BASE CB/CBS/CBSQ PER PLAN MULTI-STUD OR POST PER PLAN DE P T H P E R P L A N ±6 " 3" BATTER 3" CLR. COVER, TYP. BATTER PEDESTAL PER PLAN 8" M I N . SIMPSON COLUMN BASE CB/CBS/CBSQ PER PLAN MULTI-STUD OR POST PER PLAN DE P T H P E R P L A N ±6 " PAD REINF. PER PLAN 3" CLR. COVER, TYP. FLAT PEDESTAL PER PLAN 1" SE E N O T E TOP OF NATURAL GRADE OR COMPACT FILL TOP OF NATURAL GRADE OR COMPACT FILL PAD REINF. PER PLAN NOTE: 1" STANDOFF REQUIRED AT SIMPSON CB, OTHERWISE USE PRESSURE TREATED WOOD. ISOLATED PAD FOOTING (1)#3 "V" BAR BENT 12"Λ12" THRU STIRRUP OF COLUMN BASE (1)#3 "V" BAR BENT 12"Λ12" THRU STIRRUP OF COLUMN BASE 3" CLR. COVER MIN. 3" CLR. COVER MIN. 6 9 8 FTG. REINF. PER TYP. EXTERIOR FTG. DETAIL 12 " M I N . 7" M I N . 3" C L R . C O V E R TOP OF CONC. SLAB PER PLAN SLAB REINF. PER PLAN 0" 18" MIN. ADD #4@18" DOWELS (NOTE 1) 18" MIN. CONC. SLAB PER PLAN SLAB REINF. 7" M I N . 12 " M I N . 3" C L R . C O V E R 0" FTG. REINF PER PLAN FOR PAD FTG./ TYP. EXTERIOR FTG. DETAIL FOR CONT. FTG. COLD JOINT (ROUGHENED TO 1/4" AMPLITUDE) ANCHOR BOLT ANCHOR BOLT ADD #4@18" EXTERIOR FOOTING INTERIOR / PAD FOOTING NOTES: 1.DOWELS ARE REQUIRED WHERE ANCHOR BOLTS EMBEDMENT IS LESS THAN 7" IN FIRST POUR. 2.SLAB REBAR CAN BE BENT INTO THE FIRST POUR AND COUNTED TOWARDS REQUIRED DOWELS CROSSING COLD JOINT. 3.FOR BALANCE OF INFORMATION SEE TYPICAL FOOTING DETAILS. TYPICAL COLD JOINT IN FOOTING COLD JOINT (ROUGHENED TO 1/4" AMPLITUDE) 145710 2 24" MIN. MIN. 6" EMBEDMENT W/ SIMPSON SET-3G EXISTING SLAB NEW SLAB REBAR PER PLANS NEW TO EXISTING FOUNDATION DETAIL #4 OVERLAPPED W/ NEW REBAR TO MATCH SPACING OF TYPICAL FOOTING REBAR TOP & BOTTOM NEW SLAB PER PLANS 6" MIN. 24" EXISTING SLAB NEW SLAB PER PLANS NEW FOOTING MIN. AS DEEP AS EXISTING NEW REBAR MATCH SIZE & SPACING OF TYP. FOOTING REBAR @ TOP & BOTT. - SET-3G ESR #4057 - SPECIAL INSPECTION REQUIRED 11 1 1 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 03/15/2024 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 03/15/2024 02 / 0 1 / 2 0 2 4 1S T P L A N C O R R E C T I O N 2 02 / 2 2 / 2 0 2 4 2N D P L A N C O R R E C T I O N SD1.0 FO U N D A T I O N DE T A I L S 2 1 1402 W 10th St & Unit #2 - 101117923-245/8/2024 SIMPSON STRAP PER SCHEDULE BEAM PER PLAN POST PER PLAN STRAP SCHEDULE STRAP END LENGTH A ST12 6" B ST18 9" C ST6215 8" - 2900# 5600# CAPACITYMARK EA. SIDE END VIEWISOMETRIC VIEW EN D LE N G T H EN D LE N G T H EN D LE N G T H NOTES: 1.ADD SHIMS EA. SIDE WHERE BEAM & POST WIDTH ARE DIFFERENT (MIN. 10D PENETRATION INTO MAIN MEMBER IS REQ'D, WHERE "D" IS THE SHANK DIAMETER OF NAIL) 2.PROVIDE FULL NAILING PER MANUF. REQUIREMENTS. 3.INCREASE STRAP LENGTH ON POST SIDE WHERE THERE IS DBL. TOP PLATE BETWEEN POST AND BEAM. SIMPSON STRAP PER SCHEDULE EN D LE N G T H BEAM/POST CONNECTION NOTE: APPLICATION OF STRAP OVER PLYWOOD SHEATHING IS ACCEPTABLE. E.N. NOT REQUIRED OVER THE STRAP LENGTH WHERE STRAP APPLIED OVER PLYWOOD. DBL. ROOF RAFTERS OR BM. W/ EDGE NAILING TO ROOF SHEATHING RIDGE PER PLAN HANGER PER PLAN DBL. ROOF RAFTERS W/ EDGE NAILING TO ROOF SHEATHING. SIMPSON CS14x30"LONG STRAP FULLY NAILED PER MANUF. ROOF SHEATHING w/ EDGE NAILING TO DBL. ROOF RAFTERS DRAG DETAIL AT FLUSH RIDGE CONNECTION E.Q.E.Q. STRAP SCHEDULE SIMPSON STRAP MIN BEAM/JOIST WIDTH END LENGTH A (1) CS16 2x 18" (2) CS16 2-2x OR 3x 18" C 24" CMST14 4x 36" 1700# 3400# 4585# 6490# CAPACITY TO RECEIVE STRAP MARK D B FLUSH BEAM CONDITION FLUSH BEAM/JOIST(S) W/ LINE OF E.N. PER PLAN POST OR MULTISTUD PER PLAN DBL. TOP PL. CONT. BEAM/BLK'G PER FRAMING PLAN EQ.EQ. STUD SIMPSON STRAP PER SCHEDULE NOTE: PROVIDE FULL NAILING PER MANUF. TO DEVELOP FULL CAPACITY OF THE STRAP. DRAG STRAP AT WALL END DROP BEAM CONDITION DROP BEAM PER PLAN POST OR MULTISTUDS PER PLAN SIMPSON STRAP PER SCHEDULE EQ.EQ. DBL. TOP PL. STUD ALT. STRAP LOCATION 2-2x OR 3x(2) CS14 POST/STUD PER PLAN DBL. TOP PLATES HIP OR VALLEY BEAM (2) SIMP. LTS20 EACH SIDE OF BEAM TO POST TYP. OF (4) HIP OR VALLEY BEAM POST CONDITION WALL CONDITION NOTES: 1.PROVIDE EQUAL NUMBER OF NAILS TO BM. FOR NAIL SIZE AND SPACING OUTSIDE THE LAP LENGTH AND STUDS. PROVIDE TOTAL NUMBER OF NAILS PER MANUF. 2.NAILING OF STRAP TO DBL. TOP PLATE IS NOT REQ'D AND SHALL NOT BE COUNTED TOWARDS TOTAL NUMBER OF NAILS REQ'D BY MANUF. HIP/VALLEY BEAMS UPLIFT TIE ROOF RAFTER TO HIP/ VALLEY BEAM A A HIP BEAM PER PLAN USE SIMP. HANGER WHERE RAFTER SPAN EXCEED 8'-0" ROOF SHEATHING B.N.B.N. A-A @ HIP BEAM VALLEY BEAM PER PLAN ROOF SHEATHING B.N. A-A @ VALLEY BEAM B.N. USE SIMP. HANGER WHERE RAFTER SPAN EXCEED 8'-0" (5) -16d TOE NAIL E.A. END TO BEAM HIP/ VALLEY BEAM PER PLAN (5) -16d TOE NAIL E.A. END TO BEAM TYP. 2x ROOF RAFTER WHERE OCCUR TYP. 2x ROOF RAFTER WHERE OCCUR (5) -16d TOE NAIL E.A. END TO BEAM RIDGE BEAM PER PLAN TYPICAL ROOF RAFTER PER PLAN PLYWOOD SHEATHING USE SIMPSON LRUZ HANGERS WHEN SPAN OF RAFTERS EXCEED 10'-0" OTHERWISE USE MIN. (5) 16d TOE NAILS @ EACH RAFTER TO RIDGE ST22 @ 48" O.C. B.N. ROOF RAFTER TO FLUSH RIDGE CONNECTION SHEAR PANEL PER PLAN FULL HEIGHT BLK'G. ROOF SHEATHING SIMPSON A35 PER SHEAR WALL SCHEDULE MAX.48" O.C. SIMPSON H2.5A @ 48" O.C. U.N.O. DBL. TOP PLATE OR BM. PER PLAN ROOF RAFTERS PER PLAN POST/STUD VAULTED CEILING CONDITION B.N. E.N. 2x CONT. FASCIA w/ 2-16d FACE NAILS TO EACH RAFTER SHEAR TRANSFER AT R/R PER. TO EXTERIOR WALL SIMPSON H2.5A @ 48" O.C. U.N.O. DBL. TOP PLATE OR BM. PER PLAN ROOF RAFTERS PER PLAN POST/STUD SIMPSON A35 PER SHEAR WALL SCHEDULE MAX. 48" O.C. CJ w/ 8-16d FACE NAILS TO R/R PER PLAN. SHEAR PANEL PER PLAN w/ CEILING JOISTS CONDITION FULL HEIGHT BLK'G. ROOF SHEATHING B.N. E.N. 2x CONT. FASCIA w/ 2-16d FACE NAILS TO EACH RAFTER ALT 1: STRAP SPLICE SIMPSON STRAP PER SCHEDULE EQ.EQ. ALT 2: LAP SPLICE LAP SPLICE LENGTH PER SCHEDULE 2x STUDS (PLACE AT JOINT TYP.) 16d SEE SCHEDULE FOR REQ'D # 2x STUDS (PLACE AT JOINT TYP.) 2 1/2" (MIN.) 16d NAIL PATTERN TOP PLATE (PLAN VIEW @ LAP ZONE) NOTES: 1.NAILING SHOULD BE PER MANUFACTURER TO DEVELOP 100% CAPACITY OF THE STRAP. 2.FOR NAIL SIZE AND SPACING OUTSIDE THE LAP LENGTH REFER TO NAILING SCHEDULE OF GENERAL NOTES. 3.STAGGER NAILS AND SPACE EVENLY TO AVOID SPLITTING. TOTAL STRAP LENGTH TOP PLATE SPLICE 2x STUDS (PLACE AT JOINT TYP.)2x STUD (PLACE AT JOINT TYP.) SIMPSON STRAP PER SCHEDULE EQ.EQ. EQ.EQ. HIP CONDITION VALLEY CONDITION SIMPSON STRAP PER SCHEDULE NO. OF 16d LAP SPLICE LENGTH SIMPSON STRAP A 18 4'-0"ST22 B 28 4'-0"ST6224 C 40 6'-0" 42 ST6236 MARK E 8'-0"MSTC52 D 62 8'-0"MSTC37 (NOTE 1) SPLICE SCHEDULE @ EACH LAP (NOTE 2) LAP SPLICE STRAP SPLICE 1 2 3 4 5 6 7 8 9 CONNECTION DETAIL BEAM PER PLAN MULTISTUDS OR POST PER PLAN SIMPSON LCE4 STRAP SCHEDULE END LENGTH A CS16 18" B (2) CS16 18" 1700# 3400# CAPACITYMARK END LEN G T H END L E N G T H 2ND STRAP (WHERE OCCURS) SIMPSON CS16 PER SCHEDULE AT CONDITION B, ADD 2x4x48" LONG MEMBER TO RECEIVE 2ND CS16 & NAIL. SISTER w/ 16d @ 4" O.C. STAGG. TO ROOF RAFTER ROOF RAFTER w/ E.N. PER PLAN DBL. TOP PLATE TYP. R/R STUD/POST SIMPSON STRAP FULL DEPTH BLK'G NOTES: 1.PROVIDE FULL NAILING PER MANUFACTURER TO PROVIDE STRAP FULL CAPACITY. 2.ROOF SHEATHING NOT SHOWN FOR CLARITY. DBL. T O P P L A T E TYP. R / R BLK'G DRAG AT REENTRANT CORNER10 B.N.ROOF SHEATHING 2x R.R. OR L.V.L. RIM PER PLAN SIMPSON CLIP PER SHEAR WALL SCHEDULE (@48" O.C. MAX.) E.N. SHEAR PANEL PER PLAN ALT. LOCATION OF SIMPSON A35/LTP4 ROOF SHEATHING 2x R.R. OR L.V.L. RIM PER PLAN 2x STUD WALL2x STUD WALL ALIGNED CONDITION OFFSET CONDITION INTERIOR SHEAR TRANSFER AT ROOF RAFTER SHEAR TRANSFER R/R PARALLEL TO EXTERIOR WALL TYPICAL ROOF RAFTER PER PLAN (2) 16d's PER CONNECTION 2x4 FLAT OUTRIGGER @ 24" O.C. ROOF SHEATHING 24" MIN. SHEAR WALL PER PLAN BALLOON FRAMED STUDS 2x FLAT BLK'G CONDITION II - TRANSFER THROUGH R.R. 16d's @ 4" O.C. 2x R.R. ADJACENT TO WALL NOTCHED AT OUTRIGGERS (DO NOT OVER-CUT) E.N. B.N. 24" MIN. SHEAR WALL PER PLAN BALLOON FRAMED STUDS TYPICAL ROOF RAFTER PER PLAN (2) 16d's PER CONNECTION 2x4 FLAT OUTRIGGER @ 24" O.C. ROOF SHEATHING2x FLAT BLOCKS W/ 16d's @ 4" O.C. TO PLATE BELOW. CONDITION I - TRANSFER THROUGH BLOCKING E.N. B.N. B.N. 11 12 13 SHEAR TRANSFER (E) ROOF RAFTERS PER PLAN SIMPSON A35 PER SHEAR WALL SCHEDULE MAX. 48" O.C. (E) CEILING JOIST PER PLAN B.N. POST/STUD 2X ROOF RAFTERS ROOF SHEATHING 2x BLK'G E.N. SIMPSON H2.5A @ 48" O.C. U.N.O. CONNECTION DETAIL E.N. CL'G / FLUSH BM PER PLAN R.R. PER PLAN W/ APPROVED HANGER ROOF SHEATHING 14 1 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 03/15/2024 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 03/15/2024 02 / 0 1 / 2 0 2 4 1S T P L A N C O R R E C T I O N 2 02 / 2 2 / 2 0 2 4 2N D P L A N C O R R E C T I O N SD2.0 ST R U C T U R A L DE T A I L S 2 1 1 2 1402 W 10th St & Unit #2 - 101117923-245/8/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK 2 12/21/2023 2ND PLANCHECK A.01 CAL GREEN CODE (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 CONTRACTOR CONTRACTOR CONTRACTOR ARCHITECT ENGINEER ARCHITECT ARCHITECT ARCHITECT ARCHITECT ARCHITECT CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR ARCHITECT OWNER 1402 W 10th St & Unit #2 - 101117923-245/8/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK 2 12/21/2023 2ND PLANCHECK A.02 CAL GREEN CODE (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR CONTRACTOR OWNER OWNER CONSTRACTOR 1402 W 10th St & Unit #2 - 101117923-245/8/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK T24.1 TITLE 24 (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 2 12/21/2023 2ND PLANCHECK 1402 W 10th St & Unit #2 - 101117923-245/8/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK T24.2 TITLE 24 (CONT.) (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 2 12/21/2023 2ND PLANCHECK 1402 W 10th St & Unit #2 - 101117923-245/8/2024 IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK T24.3 TITLE 24 (CONT.) (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 2 12/21/2023 2ND PLANCHECK 1402 W 10th St & Unit #2 - 101117923-245/8/2024 2% WIDTH PER PLAN 8" MI N PAD FF WEEPSCREED  5% MIN 5% MIN BUILDING DRAINAGE DETAIL NOT TO SCALE A DRAINAGE DIRECTION AND SLOPE PROPERTY LINE CORNER POINTS AND ELEVATION DATUM FLOW LINE HARDSCAPE AREA LANDSCAPE AREA EXISTING SLOPE LEGEND: SCALE: 1"=10'-0" 010'20'20' 1 (E) MAIN HOUSE 200AMP ELECTRICAL PANEL 1.1 (E) MAIN HOUSE ELECTRICAL METER 2 PERIMETER FENCE / BLOCK WALL 3 4 5 6 7 8 9 10 11 12 13 DRIVEWAY, ON DRIVEWAY PARKING 10'X20' PER SPACE (E) LANDSCAPE (E) TREE TO BE REMOVED (E) GATE (E) WATER METER (E) GAS METER (E) WALKWAY ROOF LINE ABOVE (N) WATER METER (1" MINIMUM PER CITY REQUIREMENT) PROPOSED LOCATION OF THE NATURAL GAS METER TYPICALLY WITHIN FIVE FEET OF THE STRUCTURE’S FRONT WALL BUT NOT CLOSER THAN ONE FOOT FROM THE FRONT EDGE 14 (N) CONSUMER TANK W/ HEATPUMP 15 (N) ELECTRICAL HEATPUMP UNIT ON 3" THICK CONCRETE PAD 16 (N) ELECTRICAL SUB-PANEL 225AMPS FOR ADU 17 (N) DUAL-GANG ELEC. METER FOR ADU 18 INVERTER / METERING EQUIPMENT & PATHWAY FOR ROUTING FROM THE SOLAR ZONE TO THE MAIN SERVICE PANEL. (E) CONSUMER TANK W/ HEATPUMP 6.1 (N) LANDSCAPE 4.1 (N) WALKWAY 1.2 (E) MAIN ELEC. PANEL 200AMP BECOME SUB-PANEL UPGRADE TO 225AMP 19 SEE DETAIL ON 2/AD.10 FOR 1-HR FIRE RESISTANT EAVE PROJECTION D.01 DRAINAGE PLAN SITE PLAN KEY NOTE IT IS THE SUBCONTRACTORS RESPONSIBILITY PRIOR TO OR DURING CONSTRUCTION TO NOTIFY THE DESIGNERS OR JOB FOREMAN IN WRITING OR IN VERBAL OF ANY PERCEIVED ERRORS OR OMISSIONS IN THE PLANS AND SPECIFICATIONS OF WHICH A SUBCONTRACTOR THOROUGHLY KNOWLEDGEABLE WITH THE BUILDING CODES AND METHODS OF CONSTRUCTION SHOULD REASONABLY BE AWARE. WRITTEN OR VERBAL INSTRUCTIONS ADDRESSING SUCH PERCEIVED ERRORS OR OMISSIONS SHALL BE RECEIVED FROM THE DESIGNERS OR JOB FOREMAN PRIOR TO THE SUBCONTRACTORS BEFORE PROCEEDING WITH THE WORK. THE OWNERS WILL NOT BE RESPONSIBLE FOR ANY DEFECTS IN CONSTRUCTION IF THESE PROCEDURES ARE NOT BEING FOLLOWED. DESCRIPTIONDATEDELTA NEW DETACHED ADU 2 BEDS, 2 BATHS, LIVING, KITCHEN, DINING, LAUNDRY PROJECT CONTACT OWNERSHIP KHANH DAO 10448 SALINAS RIVER CIR FOUNTAIN VALLEY, CA 92708 PHONE: (714) 390-5154 LOAN PHAM 17021 BOLERO LN HUNTINGTON BEACH, CA 92649 PHONE: 714-614-6344 EMAIL: LOANPHAM8888@YAHOO.COM 1 11/25/2023 1ST PLANCHECK 2 12/21/2023 2ND PLANCHECK (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 SI N G L E F A M I L Y R E S I D E N C E 14 0 2 W 1 0 T H S T , SA N T A A N A , C A 9 2 7 0 3 GG 2% 2%2%2% 2% 5% 5% 2%2%2% 2% 2% 2% 5% 2% 2%2% 2% 2% 2% 2% PL 6 0 . 0 0 ' PL 111.98' PL 111.98' PL 6 0 . 0 0 ' REAR SETBACK 7'-0 1/2"27'-7" SEPARARTION 10'-0" (E) 37'-4 1/2" (E) 30'-0"30'-0" TO CENTERLINE (E ) S E T B A C K 4' - 1 " (E ) 46 ' - 6 " (E ) S E T B A C K 9' - 5 " (E) 37'-0" (E) 30'-4 1/2" (E) SEPARATION 13'-7" (E) 20'-0" (E) 11'-0 1/2" FRONT REQ. SETBACK 20'-0" SE T B A C K 5' - 0 " 29 ' - 4 " SE P A R A T I O N 6' - 2 " (E ) 18 ' - 0 " (E ) 1' - 6 " (E ) G A R A G E 36 0 S F (E ) M A I N H O U S E 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 1, 2 9 0 S F (E ) E N T R Y P O R C H 1 4 3 S F 10 T H S T ST R E E T C E N T E R L I N E (E) 5'-0" (E) 7'-0" (E) 18'-0" (E ) S T O R A G E 74 S F F.S.D 5'-0" F.S.D 5'-0" F. S . D 3' - 1 " F. S . D 3' - 1 " (N ) D E T A C H E D A D U 14 0 2 W 1 0 T H S T , U N I T 2 , SA N T A A N A , C A 9 2 7 0 3 80 0 S F (E ) 24 ' - 8 " (E ) 21 ' - 1 0 " EN T R Y P O R C H 6 0 S F 4' - 0 " 1' - 0 " 6'-0 1/2"1'-0" 4'-0"4'-0"1'-0" (E) 1'-0" 1' - 0 " 2' - 1 " 2' - 1 " (E ) 1' - 0 " (E) 1'-0" (E ) 1' - 0 " (E) 1'-0" 7'-0" 2'-6"2'-6" (E ) 16 ' - 0 " 16 17 15 18 18 KEYNOTE #19 20'-0" 14 13 10 3 6 6 3 2 2 2 18 1 1. 1 95 12 11 8 (E) CLEAN-OUT (V.I.F) (N) CLEAN-OUT (E) WALKWAY (E ) 3' - 1 " (E ) 1' - 0 " (E ) 1' - 0 " (E ) 8' - 5 " UP G R A D E T O 1 H R FI R E R A T E D W A L L (E ) 8' - 0 " 5F T P U B L I C U T I L I T Y E A S E M E N T EXCESS DRIVEWAY TO BE ADDRESSED AT A LATER TIME 3 18 9 block wall 3ft height 16 AD . 1 0 9 AD . 1 0 EX C E S S I V E CO N C R E T E 2 (E ) P O W E R P O L E 17 AD . 1 0 17 AD . 1 0 N 1402 W 10th St & Unit #2 - 101117923-245/8/2024 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/27/2023 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/27/2023 SO I L R E P O R T S-0.12 1402 W 10th St & Unit #2 - 101117923-245/8/2024 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/27/2023 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/27/2023 SO I L R E P O R T S-0.13 1402 W 10th St & Unit #2 - 101117923-245/8/2024 54312 R E V I S I O N DA T E SHEET NO.: PROJECT MANAGER: P.P. DATE: JOB NO.: 231014 12/27/2023 Pr o j e c t A d d r e s s : 14 0 2 W 1 0 T H 14 0 2 W 1 0 T H S T , S A N T A A N A , C A 9 2 7 0 3 Pr o j e c t N a m e : DE S C R I P T I O N 6 12/27/2023 SO I L R E P O R T S-0.14 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Planning & Building Agency Building Safety Division 20 Civic Center Plaza P .0. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org NOTICE TO PROPERTY OWNER Dear Property Owner: APP-13 CBC 2016 An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at \ 4 0 2. W . I O-¾i Yt , U Vl,d:: l . f Gt vt ¼. fu3,-. yft q l O '1 . , f / We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your names as the Owner-Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you, the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEGMENT AND VERIFICATION OF INFORMATON DIRECTIONS: Read and initial each statement below to signify you understand or verify this information. IN 1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner-Builder" build- ing permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my prop- erty. W __ 2. I understand building permits are not required to be signed by property owners unless they are responsible for the ccJnsiruction and are not hiring a licensed Contractor to assume this responsibility. _\£__3. I understand as an "Owner-Builder" I am the responsible party of record on the permit. I understand that I may protect m~self from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. 4. I understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts . .. lit 5. I understand if I employ or otheiwise engage any persons, other than California licensed Contractors, and the total vafueot my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer" under state and federal law. _ 4> 6. I understand if I am considered an "employer" under state and Federal law, I must register with the state and federal gov'ernment, withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment com- pensation of each "employee." I also understand my failure to abide by these laws may subject me to serious financial risk. ~7. I understand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless a// work is performed by licensed subcontrac- tors and the number of structures does not exceed four within any calendar years, or all of the work is performed under contract with a licensed general building Contractor. ,4.s. I understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any finan- cial or personal injuries sustained by any subsequent owner(s) that result from any latent construction defects in the workman- ship or materials. 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Ji-9. I understand I may obtain more information regarding my obligations as an "employer'' from the Internal R:eve~ue ~?r- vice, the United States Small Business Administration, the California Department of Benefit Payments, and the Cahfom1a D1v1- sion of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800- 321-CSLB (2752) or www.cslb.ca.gov for more information about licensed contractors. 'f 10. I am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for propord construction activity at the following ad-Cft S dress: \\.f OJ. W • \ 0~ S . U11A:t: 2. , .fct\f\h fr}A., 9 2. 7 O • 1 llf 11. I agree that, as the party legally and financially responsible for this proposed construction activity, I will abide by all applicable laws and requirements that govern Owner-Builders as well as employers. 12. I agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contactors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. Before a building permit can be issued, this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note: A copy of the property owners drivers license. form notariza- tion, or other verification acceptable to the agency is required to be presented when the permit is Issued to verify the property owners signature. Signature of Property Owner ____ ....:L:::::..~-a..;._"1__.Q_l_'(._\tv, _________ Date: ___ 0 _1<...!..f _2 _:t...1..{_v0_1._'{...L...-_ Print name of Owner LO ~N P H A \V\ ___________ _.;_ ________ _ AUTHORIZATION OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Exduding the Notice to Property Owner, the execution of which I understand is my personal responsibility, I hereby authorize the following person(s) to act as my agent(s) to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project Scope of Construction Project (or Description of Work): _______________________ _ Project Location or Address:-------------------------------- Name of Authorized Agent:--------------------------------- Address of Authorized Agent:. ______________________________ _ Phone Number of Authorized Agent: _____________________________ _ declare under penalty of perjury that I am the property owner for the address listed above and I personally filled out the above information and certify its accuracy. Property Owner's Signature: _____________________ Date:. ________ _ Print Name of Owner: __________________________ _ Note: A copy of the owners driver's license, form notarization, or other verification acceptable to the agency is re- quired to be presented when the permit Is Issued to verify the property owner's signature. 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Structural Calculations Project No.: 1 1402 W 10th St & Unit #2 - 101117923-245/8/2024 January, 18, 2023 Project: 23011 Location: 5463 Wadean PI Oakland, CA 94601, USA Client: N/A TABLE OF CONTENTS 2 1402 W 10th St & Unit #2 - 101117923-245/8/2024 ASCE 7 Hazards Report Address: 1402 W 10th St Santa Ana, California 92703 Standard:ASCE/SEI 7-16 Latitude:33.753214 Risk Category:II Longitude:-117.886871 Soil Class:D - Default (see Section 11.4.3) Elevation:104.74078946719072 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Tue Dec 26 2023 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 2https://asce7hazardtool.online/Tue Dec 26 2023 3 1402 W 10th St & Unit #2 - 101117923-245/8/2024 The ASCE 7 Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE 7 standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE 7 standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE 7 Hazard Tool. Page 2 of 2https://asce7hazardtool.online/Tue Dec 26 2023 4 1402 W 10th St & Unit #2 - 101117923-245/8/2024 5 1402 W 10th St & Unit #2 - 101117923-245/8/2024 BUILDING INFORMATION A.General: Number of stories 1 Building risk category II Design Code 2022 CBC Load standard ASCE 7-16 Design Load Combination ASD B.Lateral Loads Data: WIND STANDARD ASCE 7-16(Directional Procedure) Exposure C Wind Speed V 95 Enclosure Enclosed Building Velocity pressure qz 0.00256KzKztKdKeV2 (26.10-1) Velocity pressure exposure coefficient Kz from (Table 26.10-1) Directionality Factor Kd 0.85 (Table 26.6-1) Topographic factor defined Kzt 1 (26.8.2) Gust Effect Factor G 0.85 (26.11) Pressures for MWFRS p qGCp – qi(GCpi)(27.3-1) External pressure coefficient Cp from (Fig. 27.3-1) Internal pressure coefficient (GCpi)0.18 (Table 26.13-1)} SEISMIC STANDARD ASCE 7-16(Equivalent Lateral Force Procedure) Seismic Design Category D (Table 11.6-1) Importance factor Ie 1 (Table 1.5-2) Soil Site Class D-Default (Table 20-3-1) Response Spectral Acc. (0.2 sec) Ss 1.305 Response Spectral Acc. (1.0 sec) S1 0.465 TL (sec)8 Fa 1.2 (Table 11.4-1) Fv 1.835 (Table 11.4-2) Max. Considered earthquake acc. SMS 1.566 (11.4-1) Max. Considered earthquake acc. SM1 .853 (11.4-2) Design spectral acc. At short period SDS 1.044 (11.4-3) Design spectral acc. at 1s period SD1 0.569 (11.4-4) Response modification coefficient R 6.5 (Table 12.2-1) System overstrength coefficient Ω2.5 (Table 12.2-1) Approximate fundamental period parameters Ct = 0.02 x = 0.75 (Table 12.8-2) Building Height (ft)12.5 Building period T=Ta (sec)0.133 (12.8-7) Base Shear Adjustment Factor 1 Minimum Cs 0.046 (12.8-5 & 12.8-6) Maximum Cs 0.658 (12.8-3 & 12.8-4) Seismic response coefficient Cs 0.161 (12.8-2) Adjusted Cs 0.161 For allowable stress design V = 0.7CsW 0.112W vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Roof Loads (Load_Roof) Clay Tile 10 psf Framing 2.5 psf Sheathing (1/2" CDX)1.5 psf Ceiling 2.5 psf Insulation 1.5 psf Misc.2 psf Total De ad Load 20 psf Liv e Load 20 psf Total Load 40 psf Interior Wall (Wall_In) Insulation 1 psf Drywall 5 psf Studs 1 psf Misc.3 psf Total De ad Load 10 psf Exterior Wall (Wall_Ex) 7/8" Stucco 10 psf Insulation 1 psf Drywall 2.5 psf Studs 1 psf Misc.2.5 psf Total De ad Load 17 psf Ceiling Loads (Load_Ceiling) Ceiling 6 psf Total De ad Load 6 psf Liv e Load 10 psf Total Load 16 psf DESIGN LOADS vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 ENTRY PORCH 60 SF CL O S E T CL O S E T BED 1 10FT CL'G BED 2 10FT CL'G BATH 1 10FT CL'G BATH 2 10FT CL'G HALLWAY LIVING 10FT CL'G KITCHEN 10FT CL'G 1 2 A B D1 ROOF SHEARWALL LAYOUT Company : Project : 1402 W 10th St Job No.: 231014 Plan : N/A Designed : D.B. Checked : P.P. Date : 12/27/2023 Client : N/A 8 1402 W 10th St & Unit #2 - 101117923-245/8/2024 SECTION D1 – DIRECTION X Bui l di ng Di m ensi on (ft):B = 30.5 L = 29 M ean Hei ght = 12.5 Base Hei ght = 0.5 Sec ti on Di m ensi on (ft):Wi dth = 30.5 Depth = 29 Wi nd Hei ght = 15.5 Base Hei ght = 0.5 Pl ate Hei ght:ROOF = 10' WIND LOAD: L/B =29/30.5=0.95, Wi ndward Wal l Cpw = 0.8, Leeward Wal l Cpl = -0.5, qh = 16.3 PSF Wal l (LW) P = GCplqh = 6.93 PLF WIND HEIGHT (FT ):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wal l (WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wal l P = GCpwqz+GCplqh 18.28 18.95 19.48 20.01 20.82 21.48 ROOF ELEM ENT WDi r+WDi r-OWDi r+OWDi r- Hi p W=32.5', L=31.25', Sl ope = 18.43° WW Hi p W=32.5', L=31.25', Sl ope = 18.43° LW -2.58 63.37 31.81 28.98 63.37 -2.58 28.98 31.81 D1X_ROOF = 89.51 = 0.6 x 149.18 PLF M AX T OT AL = 89.51 PLF SEISMIC LOAD:V = 0.1124W W_ROOF: Load_Roof (DL)= 20 x 983 / 30.5 = 644.59 Wal l _Ex (DL)= 17 x 54.6 x (10/2) / 30.5 = 152.16 Wal l _In (DL)= 10 x 30 x (10/2) / 30.5 = 49.18 Cs*W = 0.1124 x (644.59 + 152.16 + 49.18)= 95.08 T OT AL SEISM IC LOAD 95.08 = 95.08 PLF Story Wx (PLF)Hx (ft) Wxxhx /su m (Wixh i) Fx (PLF) Sum (Fi)Sum (Wi)Fpx(PL F) Fpx M i n Fpx M ax Fpx Desi g n D1X_ROOF 845.93 10 1 95.08 95.08 845.93 95.08 126.16 252.33 126.16 DIAPHRAGM DESIGN: Story Wi dth (ft) Depth (ft) Sei sm i c Wi nd Di aphra g m ChordShear (p l f)Ch o rd (l b )Sh e a r (pl f)Chord (l b) D1X_ROOF 27.5 29 5 9 .8 411.2 42.4 291.8 15/32 Sheathi ng and Si ngl e-Fl oor Unbl oc ked w/8d COM M ON NAILS at 6”, 6 ”, 12” O.C. (Shear Ca p a c i ty: E=1 8 0 /W=2 5 2 ) (10 ) 16d si nker per top pl ate spl i c e SECTION D1 – DIRECTION Y Bui l di ng Di m ensi on (ft):B = 29 L = 30.5 M ean Hei ght = 12.5 Base Hei ght = 0.5 Sec ti on Di m ensi on (ft):Wi dth = 29 Depth = 30.5 Wi nd Hei ght = 15.5 Base Hei ght = 0.5 Pl ate Hei ght:ROOF = 10' WIND LOAD: L/B =30.5/29=1.05, Wi ndward Wal l Cpw = 0.8, Leeward Wal l Cpl = -0.49, qh = 16.3 PSF Wal l (LW) P = GCplqh = 6.78 PLF WIND HEIGHT (FT ):15 20 25 30 40 50 qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 Wal l (WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 Wal l P = GCpwqz+GCplqh 18.14 18.8 19.34 19.87 20.67 21.34 ROOF ELEM ENT WDi r+WDi r-OWDi r+OWDi r- Hi p W=31.25', L=32.5', Sl ope = 18.43° LW Hi p W=31.25', L=32.5', Sl ope = 18.43° WW 64.09 -2.61 29.31 32.17 -2.61 64.09 32.17 29.31 D1Y_ROOF = 89.49 = 0.6 x 149.15 PLF M AX T OT AL = 89.49 PLF SEISMIC LOAD:V = 0.1124W W_ROOF: Load_Roof (DL)= 20 x 983 / 29 = 677.93 Wal l _Ex (DL)= 17 x 58 x (10/2) / 29 = 170.00 Wal l _In (DL)= 10 x 48 x (10/2) / 29 = 82.76 Cs*W = 0.1124 x (677.93 + 170.00 + 82.76)= 104.61 T OT AL SEISM IC LOAD = 104.61 = 104.61 PLF Story Wx (PLF)Hx (ft) Wxxhx /su m (Wixh i) Fx (PLF) Sum (Fi)Sum (Wi)Fpx(PL F) Fpx M i n Fpx M ax Fpx Desi g n D1Y_ROOF 930.69 10 1 104.61 104.61 930.69 104.61 138.81 277.61 138.81 DIAPHRAGM DESIGN: Story Wi dth (ft) Depth (ft) Sei sm i c Wi nd Di aphra g m ChordShear (p l f)Ch o rd (l b )Sh e a r (pl f)Chord (l b) D1Y_ROOF 2 9 3 0 .5 66 478.4 42.5 308.4 15/32 Sheathi ng and Si ngl e-Fl oor Unbl oc ked w/8d COM M ON NAILS at 6”, 6 ”, 12” O.C. (Shear Ca p a c i ty: E=1 8 0 /W=2 5 2 ) (10 ) 16d si nker per top pl ate spl i c e vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 SHEARWALL AND HARDWARE SCHEDULES (De sign Code : 2022 CBC) A. SHEARWALL SCHEDULE Pane l Type She athing Edge Nail Fie ld Nail Se ismic Allowable (plf) Wind Allowable (plf)Sole Plate Nailing She ar Clip M udsill Anchors Ga (k/in)2x Mudsill 3x Mudsill SW1 3/8" Sheathing 8d @ 6 8d @ 12 260 364 16d Nails @ 6 A35 @ 24 5/8 x 10 @ 48 -13 SW2 3/8" Sheathing 8d @ 4 8d @ 12 380 532 16d Nails @ 4 A35 @ 16 5/8 x 10 @ 42 -19 SW3 3/8" Sheathing 8d @ 3 8d @ 12 490 686 16d Nails @ 3 A35 @ 8 5/8 x 10 @ 36 -25 SW4 3/8" Sheathing 8d @ 2 8d @ 12 640 896 16d Nails @ 2 A35 @ 8 5/8 x 10 @ 24 -39 SW5 15/32" Structural I 10d @ 2 10d @ 12 870 1218 (2) Rows Stagg, 16d Nails @ 3 A35 @ 6 5/8 x 10 @ 18 -51 SW3D 3/8" Sheathing 8d @ 3 8d @ 12 980 1372 SDS1/4x6 @ 4 (Both Sides)A35 @ 8 -5/8 x 12 @ 22 50 SW4D 3/8" Sheathing 8d @ 2 8d @ 12 1280 1792 SDS1/4x6 @ 3 (Both Sides)A35 @ 8 -5/8 x 12 @ 16 78 SW5D 15/32" Structural I 10d @ 2 10d @ 12 1740 2436 SDS1/4x6 @ 2 (Both Sides)A35 @ 6 -5/8 x 12 @ 8 102 B. HOLDOWN SCHEDULE Holdown M in. Post Conne ctors Anchor Bolt Allowable (lbs)Displace me nt all da (in)Re marks HDU2 4X4 6-SDS1/4x2 1/2 5/8"3075 0.088 HD1 HDU4 4X4 10-SDS1/4x2 1/2 5/8"4565 0.114 HD2 HDU5 4X4 14-SDS1/4x2 1/2 5/8"5645 0.115 HD3 HDU8 4X6 20-SDS1/4x2 1/2 7/8"7870 0.113 HD4 C. HOLDOWN STRAP SCHEDULE Strap M in. Post Conne ctors Allowable (lbs)Displace me nt all da (in)Re marks CS16 2X4 22-10d 1705 0.026 A (2)CS16 2-2X4 22-10d 3410 0.026 B (2)CS14 2-2X4 30-10d 4980 0.031 C CMST14 4X4 80-16d 6490 0.052 D (3)CS14 3-2X4 30-10d 7470 0.031 C* CMST12 4X6 104-16d 9200 0.069 E (2)CMST14 4X8 80-16d 12980 0.052 F (2)CMST12 6X8 104-16d 18400 0.069 G D. PLATE SPLICE STRAP SCHEDULE Straps Alt. Nails pe r top plate splice Allowable Te nsion Loads Re marksTypeGaFasteners Simpson ST22 16 18-16d 10-16d sinker 1420 A Simpson ST6224 16 28-16d 16-16d sinker 2540 B Simpson ST6236 14 40-16d 22-16d sinker 3845 C Simpson MST37 12 42-16d 24-16d sinker 5080 D Simpson MSTC52 16 62-16d 32-16d sinker 5649 E Simpson MST60 10 68-16d 36-16d sinker 6730 F Simpson CMST12x72"12 74-16d 42-16d sinker 9215 G vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 OVERTURNING LOAD COMBINATIONS (De sign Code : 2022 CBC) ULIFT DOWN 1. 0.6D - 0.6W 1. D + 0.6W 2. (0.6 - 0.14Sds)D - 0.7ρE 2. D + 0.75(L + Lr + 0.6W) 3. D + 0.75(L + S + 0.6W) 4. (1+0.105Sds)D + 0.75(L + S + 0.7ρE) 5. (1+0.14Sds)D + 0.7ρE vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 SW_LINE A 1st Floor Passe d Exterior Wall Drection X Location:(16.18, -27.33) Loads SECTION D1X_ROOF: W=1499 LB, E=1593 LB (33.5ft) Wall Self-Weight Seismic = 316 LB Strap She arwall De sign USE TYPE: SW2 Total Length (ft): 29.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 187 298 380 532 380 SW2 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1945 2382 680 226 0 0 0 1945 2382 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 2788 3355 HDU2/4X4 0.91/0.44 2788 3355 HDU2/4X4 0.91/0.44 1.523 2.400 vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 SW_LINE B 1st Floor Passe d Exterior Wall Drection X Location:(16.18, 0.00) Loads SECTION D1X_ROOF: W=1220 LB, E=1295 LB (27.25ft) Wall Self-Weight Seismic = 313 LB Strap She arwall De sign USE TYPE: SW1 Total Length (ft): 29.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 152 250 260 364 260 SW1 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1582 1993 680 226 0 0 0 1582 1993 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 2282 2850 HDU2/4X4 0.74/0.37 2282 2850 HDU2/4X4 0.74/0.37 1.604 2.400 vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 SW_LINE 1 1st Floor Passe d Exterior Wall Drection Y Location:(16.18, -27.33) Loads SECTION D1Y_ROOF: W=1298 LB, E=1517 LB (29ft) Wall Self-Weight Seismic = 310 LB Strap She arwall De sign USE TYPE: SW2 Total Length (ft): 27.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 162 285 380 532 380 SW2 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1683 2277 680 226 0 0 0 1683 2277 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 2651 3219 HDU2/4X4 0.86/0.42 2651 3219 HDU2/4X4 0.86/0.42 1.453 2.400 vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 SW_LINE 2 1st Floor Passe d Exterior Wall Drection Y Location:(45.26, -27.33) Loads SECTION D1Y_ROOF: W=1298 LB, E=1517 LB (29ft) Wall Self-Weight Seismic = 294 LB Strap She arwall De sign USE TYPE: SW2 Total Length (ft): 27.00 Total panel Length (ft): 8.00 ρ = 1.3 Pane l Width (ft)Ne t He ight (ft)H/W Actual (plf)Allowable (plf) Adjuste d Allowable (plf)SW Type Re marksWindSeismicWindSeismic A 8.00 10.00 1.25 162 283 380 532 380 SW2 Ov e rturning Force s Pane l Le ft Force s (lb)Right Force s (lb) Dup Ddown L Lr S W E Dup Ddown L Lr S W E A 680 226 0 0 0 1683 2261 680 226 0 0 0 1683 2261 Holdown & De fle ction Che ck Pane l Width (ft) Ne t He ight (ft) Le ft Ratio Right Ratio Pane l De fle ction (in) Uplift (LB) Down (LB)Holdown/Post Uplift (LB) Down (LB)Holddown/Post Actual Allowable A 8.00 10.00 2631 3199 HDU2/4X4 0.86/0.42 2631 3199 HDU2/4X4 0.86/0.42 1.443 2.400 vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 LOAD COMBINATIONS (Load Standard: ASCE 7-16) id Load case De ad Sds*De ad Liv e Roof Liv e Snow Wind Se ismic Dire ction Load Dur ation Factor CD 1 D 1 0.9 2 D + L 1 1 1 3 D + Lr 1 1 1.25 4 D + S 1 1 1.15 5 D + 0.75L + 0.75Lr 1 0.75 0.75 1.25 6 D + 0.75L + 0.75S 1 0.75 0.75 1.15 7 D + 0.6W (N)1 0.6 N_S 1.6 8 D + 0.6W (S)1 0.6 S_N 1.6 9 D + 0.6W (E)1 0.6 E_W 1.6 10 D + 0.6W (W)1 0.6 W_E 1.6 11 D + 0.75(0.6W) (N) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 N_S 1.6 12 D + 0.75(0.6W) (S) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 S_N 1.6 13 D + 0.75(0.6W) (E) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 E_W 1.6 14 D + 0.75(0.6W) (W) + 0.75L + 0.75Lr 1 0.75 0.75 0.45 W_E 1.6 15 D + 0.75(0.6W) (N) + 0.75L + 0.75S 1 0.75 0.75 0.45 N_S 1.6 16 D + 0.75(0.6W) (S) + 0.75L + 0.75S 1 0.75 0.75 0.45 S_N 1.6 17 D + 0.75(0.6W) (E) + 0.75L + 0.75S 1 0.75 0.75 0.45 E_W 1.6 18 D + 0.75(0.6W) (W) + 0.75L + 0.75S 1 0.75 0.75 0.45 W_E 1.6 19 0.6D + 0.6W (N)0.6 0.6 N_S 1.6 20 0.6D + 0.6W (S)0.6 0.6 S_N 1.6 21 0.6D + 0.6W (E)0.6 0.6 E_W 1.6 22 0.6D + 0.6W (W)0.6 0.6 W_E 1.6 23 (1.0 + 0.14Sds)D + 0.7ΩE (N)1 0.14 0.7 N_S 1.6 24 (1.0 + 0.14Sds)D + 0.7ΩE (S)1 0.14 0.7 S_N 1.6 25 (1.0 + 0.14Sds)D + 0.7ΩE (E)1 0.14 0.7 E_W 1.6 26 (1.0 + 0.14Sds)D + 0.7ΩE (W)1 0.14 0.7 W_E 1.6 27 (1.0 + 0.105Sds)D + 0.525ΩE (N) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 N_S 1.6 28 (1.0 + 0.105Sds)D + 0.525ΩE (S) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 S_N 1.6 29 (1.0 + 0.105Sds)D + 0.525ΩE (E) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 E_W 1.6 30 (1.0 + 0.105Sds)D + 0.525ΩE (W) + 0.75L + 0.75S 1 0.105 0.75 0.75 0.525 W_E 1.6 31 (0.6 - 0.14Sds)D + 0.7ΩE (N)0.6 -0.14 0.7 N_S 1.6 32 (0.6 - 0.14Sds)D + 0.7ΩE (S)0.6 -0.14 0.7 S_N 1.6 33 (0.6 - 0.14Sds)D + 0.7ΩE (E)0.6 -0.14 0.7 E_W 1.6 34 (0.6 - 0.14Sds)D + 0.7ΩE (W)0.6 -0.14 0.7 W_E 1.6 vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 02/05/2024 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Be am ID: RR1 Section type:Douglas Fir-Larch No.2 Section name:2x8 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : True Applie d Loads: Load_Roof 53.4PLF =2.67 x (20+20)/2 @ 0' to 13.75' SELF WEIGHT 2.55PLF From 0' to 13.75' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.2 Cfu = 1 Ci = 1 Cr = 1.15 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 201 0 184 0 0 0 0 0 385/0 2 201 0 184 0 0 0 0 0 385/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)1322 6.88 1700 78 1.25 Shear (lbs)349 0 1631 21 1.25 Live Deflection 0.282 6.88 0.458 62 - Total Deflection 0.590 6.88 0.688 86 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr Be am ID: RR2 Section type:Douglas Fir-Larch No.2 Section name:2x6 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : True Applie d Loads: Load_Roof 53.4PLF =2.67 x (20+20)/2 @ 0' to 7.5' SELF WEIGHT 1.93PLF From 0' to 7.5' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1.15 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 107 0 100 0 0 0 0 0 208/0 2 107 0 100 0 0 0 0 0 208/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)389 3.75 1060 37 1.25 Shear (lbs)181 7.5 1238 15 1.25 Live Deflection 0.057 3.75 0.25 23 - Total Deflection 0.118 3.75 0.375 31 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 02/05/2024 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Be am ID: 1 Section type:Douglas Fir-Larch No.2 Section name:4x10 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 545PLF =27.25 x (20+20)/2 @ 0' to 1.75' SELF WEIGHT 7.59PLF From 0' to 1.75' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.2 Cfu = 1 Ci = 1 Cr = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 245 0 238 0 0 0 0 0 484/0 2 245 0 238 0 0 0 0 0 484/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)212 0.88 5615 4 1.25 Shear (lbs)29 0 4856 1 1.25 Live Deflection 0.000 0.88 0.058 0 - Total Deflection 0.000 0.88 0.088 0 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: Lr Be am ID: 2 Section type:Ve rsa Lam 3100 Section name:3 1/2x9 1/2 Fb(+)/Fb(-) (psi): 3100/3100 Fv (psi): 285 E (psi): 2000000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 0~265PLF =0~13.25 x (20+20)/2 @ 0' to 19.25' Load_Roof 0~265PLF =0~13.25 x (20+20)/2 @ 0' to 19.25' POINT @ 19.25ft (D=125 Lr=125) SELF WEIGHT 7.8PLF From 0' to 19.25' Point Load Location Factors: Ct = 1 Cm = 1 CL = 1.00 Cr = 1 Cv = 1.03 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 258 0 210 0 0 0 0 0 468/0 2 2567 0 2466 0 0 0 0 0 5033/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)7399 14.25 17000 44 1.25 Shear (lbs)2595 14.25 7897 33 1.25 Live Deflection 0.166 19.25 0.333 50 - Total Deflection 0.326 19.25 0.5 65 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 02/05/2024 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Be am ID: 3 Section type:Ve rsa Lam 3100 Section name:3 1/2x9 1/2 Fb(+)/Fb(-) (psi): 3100/3100 Fv (psi): 285 E (psi): 2000000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 265~0PLF =13.25~0 x (20+20)/2 @ 0' to 19.25' Load_Roof 265~0PLF =13.25~0 x (20+20)/2 @ 0' to 19.25' POINT @ 0ft (D=125 Lr=125) SELF WEIGHT 7.8PLF From 0' to 19.25' Point Load Location Factors: Ct = 1 Cm = 1 CL = 1.00 Cr = 1 Cv = 1.03 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 2251 0 2162 0 0 0 0 0 4414/0 2 574 0 513 0 0 0 0 0 1088/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)6146 10.64 17000 36 1.25 Shear (lbs)2674 3 7897 34 1.25 Live Deflection 0.124 0 0.2 62 - Total Deflection 0.260 0 0.3 87 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr Be am ID: 4 Section type:Ve rsa Lam 3100 Section name:3 1/2x9 1/2 Fb(+)/Fb(-) (psi): 3100/3100 Fv (psi): 285 E (psi): 2000000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 265~0PLF =13.25~0 x (20+20)/2 @ 0' to 19.25' Load_Roof 265~0PLF =13.25~0 x (20+20)/2 @ 0' to 19.25' POINT @ 0ft (D=125 Lr=125) SELF WEIGHT 7.8PLF From 0' to 19.25' Point Load Location Factors: Ct = 1 Cm = 1 CL = 1.00 Cr = 1 Cv = 1.03 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 2523 0 2423 0 0 0 0 0 4946/0 2 303 0 252 0 0 0 0 0 555/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)6763 4.75 17000 40 1.25 Shear (lbs)2494 4.75 7897 32 1.25 Live Deflection 0.113 0 0.317 36 - Total Deflection 0.218 0 0.475 46 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 02/05/2024 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Be am ID: 5 Section type:Douglas Fir-Larch No.2 Section name:2x6 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 0~65PLF =0~3.25 x (20+20)/2 @ 0' to 4' Load_Roof 0~65PLF =0~3.25 x (20+20)/2 @ 0' to 4' SELF WEIGHT 1.93PLF From 0' to 4' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 47 0 43 0 0 0 0 0 91/0 2 91 0 87 0 0 0 0 0 177/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)137 2.32 922 15 1.25 Shear (lbs)120 4 1238 10 1.25 Live Deflection 0.006 2.08 0.133 5 - Total Deflection 0.012 2.08 0.2 6 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr Be am ID: 6 Section type:Douglas Fir-Larch No.1 Section name:6x8 Fb(+)/Fb(-) (psi): 1350/1350 Fv (psi): 170 E (psi): 1600000 Lu (ft): 16 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 100PLF =5 x (20+20)/2 @ 0' to 16' SELF WEIGHT 9.67PLF From 0' to 16' Factors: Ct = 1 Cm = 1 CL = 0.99 CF = 1 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 477 0 400 0 0 0 0 0 877/0 2 477 0 400 0 0 0 0 0 877/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)3509 8 7156 49 1.25 Shear (lbs)811 0 5844 14 1.25 Live Deflection 0.238 8 0.533 45 - Total Deflection 0.523 8 0.8 65 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 02/05/2024 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Be am ID: 7 Section type:Douglas Fir-Larch No.2 Section name:4x6 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 65PLF =3.25 x (20+20)/2 @ 0' to 5.25' Load_Roof 275PLF =13.75 x (20+20)/2 @ 0' to 5.25' POINT supp#2 of Beam 5 @ 2.75ft, (D=91 Lr=87) SELF WEIGHT 4.51PLF From 0' to 5.25' Point Load Location Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1 CT = 1 Re actions: Support D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 501 0 488 0 0 0 0 0 989/0 2 506 0 492 0 0 0 0 0 997/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)1416 2.75 2151 66 1.25 Shear (lbs)827 5.25 2888 29 1.25 Live Deflection 0.043 2.62 0.175 25 - Total Deflection 0.088 2.62 0.262 34 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 02/05/2024 Client N/A TIC Structure Design 2023 Be am ID: 8 Section type:Douglas Fir-Larch No.2 Section name:4x6 Fb(+)/Fb(-) (psi): 900/900 Fv (psi): 180 E (psi): 1600000 Lu (ft): 0 Ignore shear within (d): True Repetitive member : False Applie d Loads: Load_Roof 145PLF =7.25 x (20+20)/2 @ 0' to 7' SELF WEIGHT 4.51PLF From 0' to 7' Factors: Ct = 1 Cm = 1 CL = 1.00 CF = 1.3 Cfu = 1 Ci = 1 Cr = 1 Re actions: Suppor t D L Lr S WSN WWE ESN EWE M ax. LC (Down/Up) 1 270 0 254 0 0 0 0 0 523/0 2 270 0 254 0 0 0 0 0 523/0 Code che ck: Actual Loc.(ft)Allowe d Ratio (%)CD Moment (lbs-ft)916 3.5 2151 43 1.25 Shear (lbs)451 7 2888 16 1.25 Live Deflection 0.050 3.5 0.233 21 - Total Deflection 0.104 3.5 0.35 30 - Passe d Max Moment: D + Lr Max Shear: D + Lr Max Deflection: D + Lr 1402 W 10th St & Unit #2 - 101117923-245/8/2024 Weight of Pad POINT Weight of Pad POINT Weight of Pad POINT Footing/Pad ID: 1 Soil Bearing: SB = 2100 PSF Post with parallel to footing: Bp = 3.5 in Loads: 1200.00 LB = 150 x 2.00' x 2.00' x 2.00' From Support 2 of Beam 2 (5033LB) Design Pad: Total Point Load (Ptotal) = 6233 LB S = 3.5 + 2 x (12 + 6 ) = 39.50 in Width = 12 in Capacity of Point Load on Footing: Pcap = (SB x S x Width)/144 = 6912.50 LB Allowable Point Load on Footing: Pallow= Pcap - (Wtotalx S) / 12 =6912.50 LB Required Pad Area = Ptotal/SB = 6233.18677616608/2100 = 2.97 Ft2 USE 2'-0" SQ x 24" DEEP PAD with (3) #4 @ Bottom, E.W. Footing/Pad ID: 2 Soil Bearing: SB = 2100 PSF Post with parallel to footing: Bp = 3.5 in Loads: 1200.00 LB = 150 x 2.00' x 2.00' x 2.00' From Support 1 of Beam 3 (4414LB) Design Pad: Total Point Load (Ptotal) = 5614 LB S = 3.5 + 2 x (12 + 6 ) = 39.50 in Width = 12 in Capacity of Point Load on Footing: Pcap = (SB x S x Width)/144 = 6912.50 LB Allowable Point Load on Footing: Pallow= Pcap - (Wtotalx S) / 12 =6912.50 LB Required Pad Area = Ptotal/SB = 5613.71763448409/2100 = 2.67 Ft2 USE 2'-0" SQ x 24" DEEP PAD with (3) #4 @ Bottom, E.W. Footing/Pad ID: 3 Soil Bearing: SB = 2100 PSF Post with parallel to footing: Bp = 3.5 in Loads: 1200.00 LB = 150 x 2.00' x 2.00' x 2.00' From Support 1 of Beam 4 (4946LB) Design Pad: Total Point Load (Ptotal) = 6146 LB S = 3.5 + 2 x (12 + 6 ) = 39.50 in Width = 12 in Capacity of Point Load on Footing: Pcap = (SB x S x Width)/144 = 6912.50 LB Allowable Point Load on Footing: Pallow= Pcap - (Wtotalx S) / 12 =6912.50 LB Required Pad Area = Ptotal/SB = 6146.40769381839/2100 = 2.93 Ft2 USE 2'-0" SQ x 24" DEEP PAD with (3) #4 @ Bottom, E.W. vG23.06.30 : : : : Com pany Project 1402 W 10th Job No.231014 Plan N/A : : : : Designed D.B. Checked P.P. Date 12/28/2023 Client N/A TIC Structure Design 2023 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 1 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 GENERAL INFORMATION 01 Project Name 1402 W 10th St - Unit 2 ADU 02 Run Title Title 24 Analysis 03 Project Location 1402 W 10th St 04 City Santa Ana 05 Standards Version 2022 06 Zip code 92703 07 Software Version EnergyPro 9.2 08 Climate Zone 8 09 Front Orientation (deg/ Cardinal)0 10 Building Type Single family 11 Number of Dwelling Units 1 12 Project Scope Newly Constructed 13 Number of Bedrooms 2 14 Addition Cond. Floor Area (ft2)0 15 Number of Stories 1 16 Existing Cond. Floor Area (ft2)n/a 17 Fenestration Average U-factor 0.3 18 Total Cond. Floor Area (ft2)800 19 Glazing Percentage (%)13.13% 20 ADU Bedroom Count n/a 21 ADU Conditioned Floor Area n/a 22 Fuel Type Natural gas 23 No Dwelling Unit:No COMPLIANCE RESULTS 01 Building Complies with Computer Performance 02 This building incorporates features that require field testing and/or verification by a certified HERS rater under the supervision of a CEC-approved HERS provider. 03 This building incorporates one or more Special Features shown below 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 2 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 ENERGY DESIGN RATINGS Energy Design Ratings Compliance Margins Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Source Energy (EDR1) Efficiency1 EDR (EDR2efficiency) Total2 EDR (EDR2total) Standard Design 37.1 38.5 27.7 Proposed Design 36.9 37.9 27.4 0.2 0.6 0.3 RESULT3: PASS 1Efficiency EDR includes improvements like a better building envelope and more efficient equipment 2Total EDR includes efficiency and demand response measures such as photovoltaic (PV) system and batteries 3Building complies when source energy, efficiency and total compliance margins are greater than or equal to zero and unmet load hour limits are not exceeded •Standard Design PV Capacity: 2.07 kWdc •PV System resized to 2.07 kWdc (a factor of 2.070) to achieve 'Standard Design PV' PV scaling 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 3 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 ENERGY USE SUMMARY Energy Use Standard Design Source Energy (EDR1) (kBtu/ft2 -yr) Standard Design TDV Energy (EDR2) (kTDV/ft2 -yr) Proposed Design Source Energy (EDR1) (kBtu/ft2 -yr) Proposed Design TDV Energy (EDR2) (kTDV/ft2 -yr) Compliance Margin (EDR1) Compliance Margin (EDR2) Space Heating 0.09 0.5 0.88 6.5 -0.79 -6 Space Cooling 1.32 29.85 1.01 27.8 0.31 2.05 IAQ Ventilation 0.45 4.71 0.45 4.71 0 0 Water Heating 2.23 23.48 1.7 18.66 0.53 4.82 Self Utilization/Flexibility Credit 0 0 Efficiency Compliance Total 4.09 58.54 4.04 57.67 0.05 0.87 Photovoltaics -2.83 -85.4 -2.83 -84.84 Battery 0 0 Flexibility Indoor Lighting 0.94 8.78 0.94 8.78 Appl. & Cooking 6.52 42.16 6.47 41.68 Plug Loads 5.68 57.83 5.68 57.83 Outdoor Lighting 0.21 1.8 0.21 1.8 TOTAL COMPLIANCE 14.61 83.71 14.51 82.92 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 4 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 ENERGY USE INTENSITY Standard Design (kBtu/ft2 - yr )Proposed Design (kBtu/ft2 - yr )Compliance Margin (kBtu/ft2 - yr )Margin Percentage Gross EUI1 22.55 21.8 0.75 3.33 Net EUI2 8.13 7.38 0.75 9.23 Notes     1. Gross EUI is Energy Use Total (not including PV) / Total Building Area.     2. Net EUI is Energy Use Total (including PV) / Total Building Area. REQUIRED PV SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 DC System Size (kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth (deg) Tilt Input Array Angle (deg) Tilt: (x in 12) Inverter Eff. (%) Annual Solar Access (%) 2.07 NA Standard (14-17%)Fixed none true 150-270 n/a n/a <=7:12 96 98 REQUIRED SPECIAL FEATURES The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis. •Whole house fan •Insulation below roof deck •Northwest Energy Efficiency Alliance (NEEA) rated heat pump water heater; specific brand/model, or equivalent, must be installed 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 5 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 HERS FEATURE SUMMARY The following is a summary of the features that must be field-verified by a certified HERS Rater as a condition for meeting the modeled energy performance for this computer analysis. Additional detail is provided in the building tables below. Registered CF2Rs and CF3Rs are required to be completed in the HERS Registry •Quality insulation installation (QII) •Indoor air quality ventilation •Kitchen range hood •Minimum Airflow •Verified EER/EER2 •Fan Efficacy Watts/CFM •Verified HSPF •Verified heat pump rated heating capacity •Duct leakage testing BUILDING - FEATURES INFORMATION 01 02 03 04 05 06 07 Project Name Conditioned Floor Area (ft2)Number of Dwelling Units Number of Bedrooms Number of Zones Number of Ventilation Cooling Systems Number of Water Heating Systems 1402 W 10th St - Unit 2 ADU 800 1 2 1 1 1 ZONE INFORMATION 01 02 03 04 05 06 07 Zone Name Zone Type HVAC System Name Zone Floor Area (ft2)Avg. Ceiling Height Water Heating System 1 Status Living Area Conditioned HVAC System1 800 8 DHW Sys 1 New OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) North Wall Living Area R-15 Wall 0 Front 291 35 90 South Wall Living Area R-15 Wall 180 Back 291 39 90 West Wall Living Area R-15 Wall 270 Right 274 21 90 East Wall Living Area R-15 Wall 90 Left 274 30 90 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 6 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 OPAQUE SURFACES 01 02 03 04 05 06 07 08 Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door Area (ft2)Tilt (deg) Roof Living Area R-38 + R-19 Roof Attic n/a n/a 800 n/a n/a ATTIC 01 02 03 04 05 06 07 08 Name Construction Type Roof Rise (x in 12)Roof Reflectance Roof Emittance Radiant Barrier Cool Roof Attic Living Area Attic RoofLiving Area Ventilated 4 0.1 0.85 No No FENESTRATION / GLAZING 01 02 03 04 05 06 07 08 09 10 11 12 13 14 Name Type Surface Orientation Azimuth Width (ft) Height (ft)Mult.Area (ft2)U-factor U-factor Source SHGC SHGC Source Exterior Shading WA-3050 Window North Wall Front 0 1 15 0.3 NFRC 0.23 NFRC Bug Screen WA-3050 2 Window South Wall Back 180 1 15 0.3 NFRC 0.23 NFRC Bug Screen WB-3040 Window South Wall Back 180 1 12 0.3 NFRC 0.23 NFRC Bug Screen WB-3040 2 Window South Wall Back 180 1 12 0.3 NFRC 0.23 NFRC Bug Screen WB-3040 3 Window West Wall Right 270 1 12 0.3 NFRC 0.23 NFRC Bug Screen WC-3030 Window West Wall Right 270 1 9 0.3 NFRC 0.23 NFRC Bug Screen WA-3050 3 Window East Wall Left 90 1 15 0.3 NFRC 0.23 NFRC Bug Screen WA-3050 4 Window East Wall Left 90 1 15 0.3 NFRC 0.23 NFRC Bug Screen 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 7 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 OPAQUE DOORS 01 02 03 04 Name Side of Building Area (ft2)U-factor D1-3068 North Wall 20 0.5 SLAB FLOORS 01 02 03 04 05 06 07 08 Name Zone Area (ft2)Perimeter (ft)Edge Insul. R-value and Depth Edge Insul. R-value and Depth Carpeted Fraction Heated Slab-on-Grade Living Area 800 114 none 0 80%No OPAQUE SURFACE CONSTRUCTIONS 01 02 03 04 05 06 07 08 Construction Name Surface Type Construction Type Framing Total Cavity R-value Interior / Exterior Continuous R-value U-factor Assembly Layers R-15 Wall Exterior Walls Wood Framed Wall 2x4 @ 16 in. O. C.R-15 None / None 0.095 Inside Finish: Gypsum Board Cavity / Frame: R-15 / 2x4 Exterior Finish: 3 Coat Stucco Attic RoofLiving Area Attic Roofs Wood Framed Ceiling 2x4 @ 24 in. O. C.R-19 None / 0 0.059 Roofing: Light Roof (Asphalt Shingle) Roof Deck: Wood Siding/sheathing/decking Cavity / Frame: R-13.0 / 2x4 Around Roof Joists: R-6.0 insul. R-38 + R-19 Roof Attic Ceilings (below attic) Wood Framed Ceiling 2x4 @ 24 in. O. C.R-38 None / None 0.025 Over Ceiling Joists: R-28.9 insul. Cavity / Frame: R-9.1 / 2x4 Inside Finish: Gypsum Board 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 8 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 BUILDING ENVELOPE - HERS VERIFICATION 01 02 03 04 05 Quality Insulation Installation (QII)High R-value Spray Foam Insulation Building Envelope Air Leakage CFM50 CFM50 Required Not Required N/A n/a n/a WATER HEATING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Distribution Type Water Heater Name Number of Units Solar Heating System Compact Distribution HERS Verification Water Heater Name (#) DHW Sys 1 Domestic Hot Water (DHW)Standard DHW Heater 1 1 n/a None n/a DHW Heater 1 (1) WATER HEATERS - NEEA HEAT PUMP 01 02 03 04 05 06 07 08 Name # of Units Tank Vol. (gal)NEEA Heat Pump Brand NEEA Heat Pump Model Tank Location Duct Inlet Air Source Duct Outlet Air Source DHW Heater 1 1 40 Rheem PROPH40 T2 RH37530 (40 gal, JA13) Outside Living Area Living Area WATER HEATING - HERS VERIFICATION 01 02 03 04 05 06 07 Name Pipe Insulation Parallel Piping Compact Distribution Compact Distribution Type Recirculation Control Shower Drain Water Heat Recovery DHW Sys 1 - 1/1 Not Required Not Required Not Required None Not Required Not Required 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 9 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 SPACE CONDITIONING SYSTEMS 01 02 03 04 05 06 07 08 09 Name System Type Heating Unit Name Heating Equipment Count Cooling Unit Name Cooling Equipment Count Fan Name Distribution Name Required Thermostat Type HVAC System1 Heat pump heating cooling Heat Pump System 1 1 Heat Pump System 1 1 HVAC Fan 1 Air Distribution System 1 Setback HVAC - HEAT PUMPS 01 02 03 04 05 06 07 08 09 10 11 12 13 Name System Type Number of Units Heating Cooling Zonally Controlled Compressor Type HERS VerificationHeating Efficiency Type HSPF/HS PF2/COP Cap 47 Cap 17 Cooling Efficiency Type SEER/SE ER2 EER/EER 2/CEER Heat Pump System 1 Central split HP 1 HSPF 9.5 24000 18000 EERSEER 15 12.5 Not Zonal Single Speed Heat Pump System 1-hers-htpump HVAC HEAT PUMPS - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Verified Airflow Airflow Target Verified EER/EER2 Verified SEER/SEER2 Verified Refrigerant Charge Verified HSPF/HSPF2 Verified Heating Cap 47 Verified Heating Cap 17 Heat Pump System 1-hers-htpump Required 450 Required Not Required No Yes Yes Yes HVAC - DISTRIBUTION SYSTEMS 01 02 03 04 05 06 07 08 09 10 11 12 Name Type Design Type Duct Ins. R-value Duct Location Surface Area Bypass Duct Duct Leakage HERS Verification Supply Return Supply Return Supply Return Air Distribution System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a No Bypass Duct Sealed and Tested Air Distribution System 1-hers-dist 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 10 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 HVAC DISTRIBUTION - HERS VERIFICATION 01 02 03 04 05 06 07 08 09 Name Duct Leakage Verification Duct Leakage Target (%) Verified Duct Location Verified Duct Design Buried Ducts Deeply Buried Ducts Low-leakage Air Handler Low Leakage Ducts Entirely in Conditioned Space Air Distribution System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No HVAC - FAN SYSTEMS 01 02 03 04 Name Type Fan Power (Watts/CFM)Name HVAC Fan 1 HVAC Fan 0.35 HVAC Fan 1-hers-fan HVAC FAN SYSTEMS - HERS VERIFICATION 01 02 03 Name Verified Fan Watt Draw Required Fan Efficacy (Watts/CFM) HVAC Fan 1-hers-fan Required 0.35 INDOOR AIR QUALITY (IAQ) FANS 01 02 03 04 05 06 07 08 09 Dwelling Unit Airflow (CFM)Fan Efficacy (W/CFM)IAQ Fan Type Includes Heat/Energy Recovery? IAQ Recovery Effectiveness - SRE/ASRE Includes Fault Indicator Display?HERS Verification Status SFam IAQVentRpt 46 0.35 Exhaust No n/a / n/a No Yes 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 11 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 COOLING VENTILATION 01 02 03 04 05 06 07 08 09 Name Airflow Rate (CFM/ft2)Cooling Vent CFM Cooling Vent Watts/CFM Total Watts Number of Fans CFVCS Type Exhausts to HERS Verification Whole House Fan 1.5 1200 0.14 168 1 Not a CFVCS Attic 1402 W 10th St & Unit #2 - 101117923-245/8/2024 CERTIFICATE OF COMPLIANCE - RESIDENTIAL PERFORMANCE COMPLIANCE METHOD CF1R-PRF-01E Project Name:1402 W 10th St - Unit 2 ADU Calculation Date/Time:2023-12-21T16:52:06+07:00 (Page 12 of 12) Calculation Description:Title 24 Analysis Input File Name:1402 W 10th St, Unit 2 - ADU.ribd22x Registration Number:Registration Date/Time:    HERS Provider: CA Building Energy Efficiency Standards - 2022 Residential Compliance Report Version: 2022.0.000 Schema Version: rev 20220901 Report Generated: 2023-12-21   01:53:16 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT 1. I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (If applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1.I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance. 2.I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 3.The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. Responsible Designer Name:Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone:   1402 W 10th St & Unit #2 - 101117923-245/8/2024 1402 W 10th St & Unit #2 - 101117923-245/8/2024