Loading...
HomeMy WebLinkAbout1401 E Joana Dr - Plan***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg#: 101119631 Elec#: 20183059 Approvals: Elec: M Smith 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 Danny Nguyen (Jun 4, 2024 17:06 PDT) Danny Nguyen 1401 E Joana Dr 11/27/2024 Danny Auth Letter Final Audit Report 2024-06-05 Created:2024-06-04 By:Empower Interconnections (interconnection@mpwrsolar.com) Status:Signed Transaction ID:CBJCHBCAABAAeOiwpBBrg1fJK_nTp7QLm4mWEGdep7Iz "Danny Auth Letter" History Document created by Empower Interconnections (interconnection@mpwrsolar.com) 2024-06-04 - 8:19:04 PM GMT Document emailed to Danny Nguyen (jasont839@gmail.com) for signature 2024-06-04 - 8:19:08 PM GMT Email viewed by Danny Nguyen (jasont839@gmail.com) 2024-06-05 - 0:06:02 AM GMT Signer Danny Nguyen (jasont839@gmail.com) entered name at signing as Danny Nguyen 2024-06-05 - 0:06:35 AM GMT Document e-signed by Danny Nguyen (jasont839@gmail.com) Signature Date: 2024-06-05 - 0:06:37 AM GMT - Time Source: server Agreement completed. 2024-06-05 - 0:06:37 AM GMT 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : UNIRAC 1411 Broadway Blvd, NE Albuquerque, NM 87102 RE: Solar Array Installation at 1401 E Joana Dr, Santa Ana, CA 92705, USA To Whom it May Concern, CODE REFERENCES: BUILDING CODE: 2022 CALIFORNIA BUILDING CODE 2021 INTERNATIONAL BUILDING CODE ASCE 7-16 SCOPE OF WORK: DESIGN PARAMETERS RISK CATEGORY : DESIGN WIND SPEED : mph WIND EXPOSURE : GROUND SNOW LOAD : psf SEISMIC DESIGN CATEGORY : EXISTING ROOF STRUCTURE ROOF : 2x6 Rafters @ 24" O.C. ROOF MATERIAL : Asphalt Shingle CONNECTION TO ROOF STRUCTURE MOUNTING CONNECTION : II Danny Nguyen PE 05-31-2024 Roof structural framing plan has been reviewed for additional loading due to installation of the roof mounted solar PV addition. The structural review that follows, including plans and calculations, only apply to the section of the roof that is directly supporting the solar PV system and its supporting elements. 31 May 2024 Per your request, we have reviewed the existing structure at the above referenced site. The purpose of our review was to determine the adequacy of the existing structure to support the proposed installation of solar panels on the roof per layout plan. 95 B 0 *null (2) #14 WOOD SCREWS w/ MIN. 1.55" EMBEDMENT INTO (E) 2x FRAMING MEMBER @ MAX. 48" o.c. ALONG RAILS (2) RAILS PER ROW OF PANELS, EVENLY SPACED. PANEL LENGTH PERPENDICULAR TO RAIL NOT TO EXCEED 74" Page 1 1401 E Joana Dr 11/27/2024 OBSERVED CONDITIONS: CONCLUSIONS: LIMITATIONS: Praneet R Erusu, P.E. Principal Engineer Erusu Consultants US Inc. Installation of the solar panels must be performed in accordance with manufacturer recommendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. Existing Roof and structural members are assumed to be in good and serviceable condition. The contractor must notify Erusu Consultants US Inc. should any damage, deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. The use of solar panel support span tables provided by others are allowed only where the building type, site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. The design of the solar panel racking (mounts, rails), etc., and electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Erusu Consultants US Inc. assumes no responsibility for improper installation of the solar array. The observed roof framing is described below. If field conditions differ, the contractor shall notify the engineer prior to starting construction. The roof framing is supported by 2x6 Rafters @ 24" O.C are spanning between load bearing walls. The maximum allowed clear span of rafter is 16ft, to be verified in field by the contractor. Based upon our review, we conclude that the existing structure is adequate to support the proposed solar panel installation. In the area of the solar array, other live loads will not be present or will be greatly reduced (2022 CBC, Section 1607.14.4). The gravity loads and the stresses of the structural elements, in the area of the solar array are either decreased or increased by no more than 5%. Therefore, the requirements of Section 503.3 of the 2022 CEBC are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 10" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case. Regarding seismic loads, we conclude that any additional forces will be small. Conservatively neglecting the weight of existing wall materials, the installation of the solar panels represents an increase in the total weight (and resulting seismic load) of 3.6%. Because the increase in lateral forces is less than 10%, this addition meets the requirements of the exception in Section 503.4 of the 2022 CEBC. Thus the existing lateral force resisting system is permitted to remain unaltered. Page 2 31 May 2024 EXP : 30 Sep 2025 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : Address : Site Plan: Danny Nguyen PE 05-31-2024 1401 E Joana Dr, Santa Ana, CA 92705, USA Page 3 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : Roof Dead Load Roof Slope = : Angle = Roof Live Load Roof Live Load = psf (Refer ASCE 7-16, Table 4.3-1) Roof Live Load with PV Array = psf 2022 CBC, Section 1607.14.4 (Ceiling load and MEP is assumed to be not supported by rafters) 20 0 PV Array 3 1.05 2.2 1.05 MEP & Misc. 1.5 Asphalt Shingles 4 1.05 4 12 18 Material Material Weight (psf) 2.32 1.50 12.88 1/2" Plywood 1.1 1.05 Framing 3 1.05 3.16 1/2" Gypsum Ceiling Danny Nguyen PE 05-31-2024 DL = Increase due to Roof Slope Plan Projected Material Weight (psf) 4.22 1.16 3.16 0.53Insulation 0.5 1.05 Page 4 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : Danny Nguyen PE 05-31-2024 Summary of Gravity Loads Dead Load, D = psf Roof Live Load, Lr = psf Gravity Load Comparison (D + Lr)/Cd = psf (Cd = 0.9 for D, 1.15 for S, 1.25 for Lr) Max Loading = psf Proposed to Current Loading Ratio =O.K. Gravity Loading with PV Array is not stressing the current framing system by more that 5% of the original configuration. Per Section 503.3 of 2022 California Existing Building Code the structure is allowed to remain unaltered for gravity loading 30.32 17.83 59%< 105% 30.32 17.83 20.00 0.00 Existing With PV Array Existing With PV Array 12.88 16.05 Page 5 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : Wind Load Calculation Wind Loads - ASCE 7-16 Chapter 26 & 29 Width of the Building, B = ft (Approximate) V = mph Exposure = Average height of building, z = ft - avg (Approximate) ft (Refer ASCE 7-16, Table 26.11-1) α =Zg =ft (Refer ASCE 7-16, Table 26.11-1) Kh & Kz =2.01(z/Zg)^(2/α) = Kzt =(Refer ASCE 7-16, Equation 26.8-1) Kd =(Refer ASCE 7-16, Table 26.6.1) Ke =(Refer ASCE 7-16, Table 26.9-1) qh ='.00256 KzKztKdKeV² =psf (Refer ASCE 7-16, Section 26.10-1) Building Classification = Solar Panel Components and Cladding p C&C = qh(GCp)(ϒe)(ϒa)ASCE 7-16 Chaper 29.4.4 Module Length =in Module Width =in Area of Module =ft2 Roof Pitch =: Slope =degrees Gable Roof = ϒe= ϒa= (Refer ASCE 7-16, Figure 29.4-8) 12 18 21.1 74 7° < θ ≤ 20° 1.5 11.29 4.0 41.1 95 B 15 0.57 Enclosed 0.8 zmin = 30 7 1 53 1 0.85 Danny Nguyen PE 05-31-2024 1200 Page 6 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : Danny Nguyen PE 05-31-2024 Zone 1 Uplift External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf Zone 2 Uplift External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf All Zone Downward External Wind pressure coefficient GCp = External Wind pressure, qGCp = psf Maximum Uplift Wind Pressure, p = psf Minimum Downward Wind Pressure ,p =psf Wood Screw Connection Check (ASD) Tributary Width =in (Max Spacing of fasteners along Rails) Tributary Length =in (Half Panel Length) Tributary Area =ft2 Wood Screw Number = Cd = (Refer NDS Table 2.3.2) Embedment = in Grade of Wood = #2 ( or better) G = Capacity = lb/in (Refer NDS Table 12.2B) Number of Screws in Tension = Prying Coefficient = Capacity of Fasteners = lb Demand Zone 1 Zone 2 0.43 Pressure ASD (0.6W)(psf) -16.3 -21.1 12.3 260.6 609 DCR 12.3 200.4 609 0.33 Capacity (lb)Tributary Area (ft2) Uplift (lb)Zone 0.5 172 2 1.4 609 48 0.5 6.8 (Measured from top of the framing member to tapered end of wood screw, embedment in sheathing and tapered tip of screw is not included) DF -35.21 -2 -27.088 -35.21 16.0 37 12.3 #14 1.6 1.55 -2.6 Page 7 1401 E Joana Dr 11/27/2024 Wood Beam LIC# : KW-06014559, Build:20.23.05.01 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2023 DESCRIPTION:2x6 Rafters @ 24" o.c. (Wind Condition_Downward) (Strength Check) Project File: 2x6 joist @ 24 o.c_copy.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.00810 ksf, Tributary Width = 2.0 ft, (Existing Roof Dead Load) Point Load : D = 0.0370, W = 0.1970 k @ 2.60 ft, (Solar Panel Load) Point Load : D = 0.0370, W = 0.1970 k @ 6.60 ft, (Solar Panel Load) Uniform Load : Lr = 0.020, W = 0.0160 ksf, Extent = 0.0 -->> 1.60 ft, Tributary Width = 2.0 ft, (Existing Wind & Roof Live Load) Uniform Load : Lr = 0.020, W = 0.0160 ksf, Extent = 13.40 -->> 16.0 ft, Tributary Width = 2.0 ft, (Existing Wind & Roof Live Load) Load for Span Number 2 Uniform Load : D = 0.00810, Lr = 0.020, W = 0.0160 ksf, Tributary Width = 2.0 ft, (Existing Roof Load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.997: 1 Load Combination +D+0.60W+H Span # where maximum occurs Span # 1 Location of maximum on span 6.615 ft 66.14 psi= = 2,152.80 psi 2x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+0.60W+H = = = 288.00 psi== Section used for this span 2x6 Maximum Shear Stress Ratio 0.230 : 1 0.000 ft= = 2,145.94 psi Maximum Deflection 104 >=104 110 Ratio =76 >=75 Max Downward Transient Deflection 1.337 in 143Ratio =>=104 Max Upward Transient Deflection -0.460 in Ratio = Max Downward Total Deflection 1.735 in Ratio =>=75 Max Upward Total Deflection -0.626 in fb: Actual F'b fv: Actual F'v Span: 1 : W Only Span: 2 : W Only Span: 1 : +D+0.60W+H Span: 2 : +D+0.60W+H .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 16.0 ft 1 0.903 0.194 0.90 1.300 1.151.00 1.00 0.69 1,093.5 1,211.0 0.17 162.01.00 31.51.00 1.00Length = 2.0 ft 2 0.042 0.194 0.90 1.300 1.151.00 1.00 0.03 51.4 1,211.0 0.02 162.01.00 31.51.00 1.00+D+L+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 Page 8 1401 E Joana Dr 11/27/2024 Wood Beam LIC# : KW-06014559, Build:20.23.05.01 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2023 DESCRIPTION:2x6 Rafters @ 24" o.c. (Wind Condition_Downward) (Strength Check) Project File: 2x6 joist @ 24 o.c_copy.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 16.0 ft 1 0.813 0.175 1.00 1.300 1.151.00 1.00 0.69 1,093.5 1,345.5 0.17 180.01.00 31.51.00 1.00Length = 2.0 ft 2 0.038 0.175 1.00 1.300 1.151.00 1.00 0.03 51.4 1,345.5 0.02 180.01.00 31.51.00 1.00+D+Lr+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.700 0.187 1.25 1.300 1.151.00 1.00 0.74 1,177.4 1,681.9 0.23 225.01.00 42.11.00 1.00Length = 2.0 ft 2 0.106 0.187 1.25 1.300 1.151.00 1.00 0.11 178.4 1,681.9 0.09 225.01.00 42.11.00 1.00+D+S+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.707 0.152 1.15 1.300 1.151.00 1.00 0.69 1,093.5 1,547.3 0.17 207.01.00 31.51.00 1.00Length = 2.0 ft 2 0.033 0.152 1.15 1.300 1.151.00 1.00 0.03 51.4 1,547.3 0.02 207.01.00 31.51.00 1.00+D+0.750Lr+0.750L+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.688 0.170 1.25 1.300 1.151.00 1.00 0.73 1,156.4 1,681.9 0.21 225.01.00 38.21.00 1.00Length = 2.0 ft 2 0.087 0.170 1.25 1.300 1.151.00 1.00 0.09 146.6 1,681.9 0.07 225.01.00 38.21.00 1.00+D+0.750L+0.750S+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.707 0.152 1.15 1.300 1.151.00 1.00 0.69 1,093.5 1,547.3 0.17 207.01.00 31.51.00 1.00Length = 2.0 ft 2 0.033 0.152 1.15 1.300 1.151.00 1.00 0.03 51.4 1,547.3 0.02 207.01.00 31.51.00 1.00+D+0.60W+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.997 0.230 1.60 1.300 1.151.00 1.00 1.35 2,145.9 2,152.8 0.36 288.01.00 66.11.00 1.00Length = 2.0 ft 2 0.052 0.230 1.60 1.300 1.151.00 1.00 0.07 112.3 2,152.8 0.05 288.01.00 66.11.00 1.00+D+0.750Lr+0.750L+0.450W+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.904 0.222 1.60 1.300 1.151.00 1.00 1.23 1,945.7 2,152.8 0.35 288.01.00 63.81.00 1.00Length = 2.0 ft 2 0.089 0.222 1.60 1.300 1.151.00 1.00 0.12 192.3 2,152.8 0.09 288.01.00 63.81.00 1.00+D+0.750L+0.750S+0.450W+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.875 0.200 1.60 1.300 1.151.00 1.00 1.19 1,882.8 2,152.8 0.32 288.01.00 57.51.00 1.00Length = 2.0 ft 2 0.045 0.200 1.60 1.300 1.151.00 1.00 0.06 97.1 2,152.8 0.05 288.01.00 57.51.00 1.00+0.60D+0.60W+0.60H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.794 0.186 1.60 1.300 1.151.00 1.00 1.08 1,708.5 2,152.8 0.29 288.01.00 53.61.00 1.00Length = 2.0 ft 2 0.043 0.186 1.60 1.300 1.151.00 1.00 0.06 91.8 2,152.8 0.04 288.01.00 53.61.00 1.00+D+0.70E+0.60H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.508 0.109 1.60 1.300 1.151.00 1.00 0.69 1,093.5 2,152.8 0.17 288.01.00 31.51.00 1.00Length = 2.0 ft 2 0.024 0.109 1.60 1.300 1.151.00 1.00 0.03 51.4 2,152.8 0.02 288.01.00 31.51.00 1.00+D+0.750L+0.750S+0.5250E+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.508 0.109 1.60 1.300 1.151.00 1.00 0.69 1,093.5 2,152.8 0.17 288.01.00 31.51.00 1.00Length = 2.0 ft 2 0.024 0.109 1.60 1.300 1.151.00 1.00 0.03 51.4 2,152.8 0.02 288.01.00 31.51.00 1.00+0.60D+0.70E+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.305 0.066 1.60 1.300 1.151.00 1.00 0.41 656.1 2,152.8 0.10 288.01.00 18.91.00 1.00Length = 2.0 ft 2 0.014 0.066 1.60 1.300 1.151.00 1.00 0.02 30.8 2,152.8 0.01 288.01.00 18.91.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+0.60W+H 1 1.7350 7.687 0.0000 0.000 +D+0.60W+H20.0000 7.687 -0.6256 2.000 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.380 0.440 Max Upward from Load Combinations 0.380 0.440 Max Upward from Load Cases 0.332 0.260 +D+H 0.180 0.185 +D+L+H 0.180 0.185 +D+Lr+H 0.245 0.369 +D+S+H 0.180 0.185 +D+0.750Lr+0.750L+H 0.228 0.323 Page 9 1401 E Joana Dr 11/27/2024 Wood Beam LIC# : KW-06014559, Build:20.23.05.01 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2023 DESCRIPTION:2x6 Rafters @ 24" o.c. (Wind Condition_Downward) (Strength Check) Project File: 2x6 joist @ 24 o.c_copy.ec6 Project Title: Engineer: Project ID: Project Descr: Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +D+0.750L+0.750S+H 0.180 0.185 +D+0.60W+H 0.380 0.341 +D+0.750Lr+0.750L+0.450W+H 0.378 0.440 +D+0.750L+0.750S+0.450W+H 0.330 0.302 +0.60D+0.60W+0.60H 0.307 0.267 +D+0.70E+0.60H 0.180 0.185 +D+0.750L+0.750S+0.5250E+H 0.180 0.185 +0.60D+0.70E+H 0.108 0.111 D Only 0.180 0.185 Lr Only 0.064 0.184 W Only 0.332 0.260 H Only Page 10 1401 E Joana Dr 11/27/2024 Wood Beam LIC# : KW-06014559, Build:20.23.05.01 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2023 DESCRIPTION:2x6 Rafters @ 24" o.c. (Wind Condition_Uplift) (Strength Check) Project File: 2x6 joist @ 24 o.c_copy.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Repetitive Member Stress Increase Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight NOT internally calculated and added Load for Span Number 1 Uniform Load : D = 0.00810 ksf, Tributary Width = 2.0 ft, (Existing Roof Dead Load) Point Load : D = 0.0370, W = -0.4340 k @ 2.60 ft, (Solar Panel Load) Point Load : D = 0.0370, W = -0.4340 k @ 6.60 ft, (Solar Panel Load) Uniform Load : Lr = 0.020, W = -0.0350 ksf, Extent = 0.0 -->> 1.60 ft, Tributary Width = 2.0 ft, (Existing Wind & Roof Live Load) Uniform Load : Lr = 0.020, W = -0.0350 ksf, Extent = 13.40 -->> 16.0 ft, Tributary Width = 2.0 ft, (Existing Wind & Roof Live Load) Load for Span Number 2 Uniform Load : D = 0.00810, Lr = 0.020, W = -0.0350 ksf, Tributary Width = 2.0 ft, (Existing Roof Load) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.903: 1 Load Combination +D+H Span # where maximum occurs Span # 1 Location of maximum on span 6.615 ft 57.44 psi= = 1,210.95 psi 2x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +0.60D+0.60W+0.60H = = = 288.00 psi== Section used for this span 2x6 Maximum Shear Stress Ratio 0.199 : 1 0.000 ft= = 1,093.50 psi Maximum Deflection 65 >=46 120 Ratio =126 >=120 Max Downward Transient Deflection 1.013 in 46Ratio =>=46 Max Upward Transient Deflection -2.944 in Ratio = Max Downward Total Deflection 0.398 in Ratio =>=120 Max Upward Total Deflection -0.378 in fb: Actual F'b fv: Actual F'v Span: 2 : W Only Span: 2 : Lr Only Span: 2 : +0.60D+0.60W+0.60H Span: 2 : +D+Lr+H .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu +D+H 0.0 0.00 0.00.0 1.00Length = 16.0 ft 1 0.903 0.194 0.90 1.300 1.151.00 1.00 0.69 1,093.5 1,211.0 0.17 162.01.00 31.51.00 1.00Length = 2.0 ft 2 0.042 0.194 0.90 1.300 1.151.00 1.00 0.03 51.4 1,211.0 0.02 162.01.00 31.51.00 1.00+D+L+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 Page 11 1401 E Joana Dr 11/27/2024 Wood Beam LIC# : KW-06014559, Build:20.23.05.01 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2023 DESCRIPTION:2x6 Rafters @ 24" o.c. (Wind Condition_Uplift) (Strength Check) Project File: 2x6 joist @ 24 o.c_copy.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00Length = 16.0 ft 1 0.813 0.175 1.00 1.300 1.151.00 1.00 0.69 1,093.5 1,345.5 0.17 180.01.00 31.51.00 1.00Length = 2.0 ft 2 0.038 0.175 1.00 1.300 1.151.00 1.00 0.03 51.4 1,345.5 0.02 180.01.00 31.51.00 1.00+D+Lr+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.700 0.187 1.25 1.300 1.151.00 1.00 0.74 1,177.4 1,681.9 0.23 225.01.00 42.11.00 1.00Length = 2.0 ft 2 0.106 0.187 1.25 1.300 1.151.00 1.00 0.11 178.4 1,681.9 0.09 225.01.00 42.11.00 1.00+D+S+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.707 0.152 1.15 1.300 1.151.00 1.00 0.69 1,093.5 1,547.3 0.17 207.01.00 31.51.00 1.00Length = 2.0 ft 2 0.033 0.152 1.15 1.300 1.151.00 1.00 0.03 51.4 1,547.3 0.02 207.01.00 31.51.00 1.00+D+0.750Lr+0.750L+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.688 0.170 1.25 1.300 1.151.00 1.00 0.73 1,156.4 1,681.9 0.21 225.01.00 38.21.00 1.00Length = 2.0 ft 2 0.087 0.170 1.25 1.300 1.151.00 1.00 0.09 146.6 1,681.9 0.07 225.01.00 38.21.00 1.00+D+0.750L+0.750S+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.707 0.152 1.15 1.300 1.151.00 1.00 0.69 1,093.5 1,547.3 0.17 207.01.00 31.51.00 1.00Length = 2.0 ft 2 0.033 0.152 1.15 1.300 1.151.00 1.00 0.03 51.4 1,547.3 0.02 207.01.00 31.51.00 1.00+D+0.60W+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.569 0.156 1.60 1.300 1.151.00 1.00 0.77 1,224.4 2,152.8 0.25 288.01.00 44.91.00 1.00Length = 2.0 ft 2 0.038 0.156 1.60 1.300 1.151.00 1.00 0.05 81.9 2,152.8 0.04 288.01.00 44.91.00 1.00+D+0.750Lr+0.750L+0.450W+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.270 0.088 1.60 1.300 1.151.00 1.00 0.37 582.1 2,152.8 0.14 288.01.00 25.51.00 1.00Length = 2.0 ft 2 0.022 0.088 1.60 1.300 1.151.00 1.00 0.03 46.7 2,152.8 0.02 288.01.00 25.51.00 1.00+D+0.750L+0.750S+0.450W+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.300 0.089 1.60 1.300 1.151.00 1.00 0.41 645.0 2,152.8 0.14 288.01.00 25.81.00 1.00Length = 2.0 ft 2 0.023 0.089 1.60 1.300 1.151.00 1.00 0.03 48.6 2,152.8 0.02 288.01.00 25.81.00 1.00+0.60D+0.60W+0.60H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.772 0.199 1.60 1.300 1.151.00 1.00 1.05 1,661.8 2,152.8 0.32 288.01.00 57.41.00 1.00Length = 2.0 ft 2 0.048 0.199 1.60 1.300 1.151.00 1.00 0.06 102.4 2,152.8 0.05 288.01.00 57.41.00 1.00+D+0.70E+0.60H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.508 0.109 1.60 1.300 1.151.00 1.00 0.69 1,093.5 2,152.8 0.17 288.01.00 31.51.00 1.00Length = 2.0 ft 2 0.024 0.109 1.60 1.300 1.151.00 1.00 0.03 51.4 2,152.8 0.02 288.01.00 31.51.00 1.00+D+0.750L+0.750S+0.5250E+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.508 0.109 1.60 1.300 1.151.00 1.00 0.69 1,093.5 2,152.8 0.17 288.01.00 31.51.00 1.00Length = 2.0 ft 2 0.024 0.109 1.60 1.300 1.151.00 1.00 0.03 51.4 2,152.8 0.02 288.01.00 31.51.00 1.00+0.60D+0.70E+H 1.300 1.151.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 16.0 ft 1 0.305 0.066 1.60 1.300 1.151.00 1.00 0.41 656.1 2,152.8 0.10 288.01.00 18.91.00 1.00Length = 2.0 ft 2 0.014 0.066 1.60 1.300 1.151.00 1.00 0.02 30.8 2,152.8 0.01 288.01.00 18.91.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections W Only10.0000 0.000 -2.9443 7.419 W Only 2 1.0131 2.000 0.0000 7.419 . Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.245 0.369 Max Upward from Load Combinations 0.245 0.369 Max Upward from Load Cases 0.180 0.185 Max Downward from all Load Conditio -0.731 -0.571 Max Downward from Load Combinations -0.330 -0.231 Max Downward from Load Cases (Resis -0.731 -0.571 +D+H 0.180 0.185 +D+L+H 0.180 0.185 Page 12 1401 E Joana Dr 11/27/2024 Wood Beam LIC# : KW-06014559, Build:20.23.05.01 ERUSU CONSULTANTS US (c) ENERCALC INC 1983-2023 DESCRIPTION:2x6 Rafters @ 24" o.c. (Wind Condition_Uplift) (Strength Check) Project File: 2x6 joist @ 24 o.c_copy.ec6 Project Title: Engineer: Project ID: Project Descr: Load Combination Support 1 Support 2 Support 3 Vertical Reactions Support notation : Far left is #1 Values in KIPS +D+Lr+H 0.245 0.369 +D+S+H 0.180 0.185 +D+0.750Lr+0.750L+H 0.228 0.323 +D+0.750L+0.750S+H 0.180 0.185 +D+0.60W+H -0.258 -0.157 +D+0.750Lr+0.750L+0.450W+H -0.100 0.066 +D+0.750L+0.750S+0.450W+H -0.149 -0.072 +0.60D+0.60W+0.60H -0.330 -0.231 +D+0.70E+0.60H 0.180 0.185 +D+0.750L+0.750S+0.5250E+H 0.180 0.185 +0.60D+0.70E+H 0.108 0.111 D Only 0.180 0.185 Lr Only 0.064 0.184 W Only -0.731 -0.571 H Only Page 13 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : Seismic Ground Motion Values Danny Nguyen PE 05-31-2024 Page 14 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : Seismic Design Force Seismic Loads - ASCE 7-16 Chapter 13 Seismic Force Component Amplification Factor, ap= (Refer ASCE 7-16, Table 13.6 -1) Overstrength Factor, Ωo = (Refer ASCE 7-16, Table 13.6 -1) Component Importance Factor, Ip= SDS = Average roof height of structure,h =ft z/h =z/h should not exceed 1 Frame Weight Wp = psf Seismic Design Force on Solar framing structure Max Fp =1.6 x SDS x Ip X Wp =psf Min Fp =0.3 x SDS x Ip X Wp =psf Horizontal Seismic Design Load Fp =psf Vertical Seismic Design Load Fv =psf0.67 2.68 5.37 1.01 3.16 FP = ((0.4 x ap x SDS x Wp)/ (Rp / Ip)) x ((1+2(z/h)) =2.68 psf 15 1 Height in structure at point of attachment, z = 15 ft 1.00 1.50 1.06 1.00 Seismic Coefficients for Mechanical and Electrical components = Component Response Modification Factor, Rp= 1.50 Danny Nguyen PE 05-31-2024 12 Other mechanical or electrical components. (Refer ASCE 7-16, Table 13.6 -1) Page 15 1401 E Joana Dr 11/27/2024 Project : Project Number: By : Date : Danny Nguyen PE 05-31-2024 Check for Increase in overall seismic loads Module Area =ft2 Number of Modules = Total Array Area =ft2 Array Load = psf Number of Existing Modules = Exisitng Array Area =ft2 Total Array Wt. = lb Total Roof Area =ft2 DL of Roof = psf Total Wt of Roof = lb Increase in Seismic Wt = < 12.88 31955 3.6% 10% Conservatively the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less than 10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2022 CEBC. 21.1 18 380.18 2480.2 3.00 1140.5 0 0.00 Page 16 1401 E Joana Dr 11/27/2024 Empower Solar 1300 E. Shaw Ave #173 Fresno, CA, 93710800-306-6953 CSLB#1057693 - C10 To Whom It May Concern: I, Scott Forster, am the license holder for Empower Solar, contractor license C-10 #1057693 and certify to the accuracy of this authorization form. I authorize the following Empower employee(s) to apply for, sign, and file all documents necessary to obtain any business license and/or permit for Empower Solar.  Erica Heron Name: Scott Forster Signature: Date: 01/04/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024 1401 E Joana Dr 11/27/2024