Loading...
HomeMy WebLinkAbout1506 E Clemensen Ave & #2 - PlanPROPERTY LINE 72' PROPERTY LINE 72' PR O P E R T Y L I N E 1 0 0 ' PR O P E R T Y L I N E 1 0 0 ' (E) SFD 2- STORY 2,680 SQ.FT. (E)DRIVEWAY (E)BACK YARD (E)FRONT YARD (E ) D R A I N 2% S L O P E (E ) D R A I N 2% S L O P E (E ) D R A I N 2% S L O P E (E ) D R A I N 2% S L O PE (E)PAVEMENT (E)EASEMENT (E ) D R I V E W A Y (E ) W A T E R HE A T E R (E)GAS METER (E)GARAGE 440 SQ.FT. (E) SIDEWALK (E) PARKWAY CLEMENSEN AVE 25 ' - 2 " 22 ' - 2 " 1 7 ' - 7 " 35 ' - 1 " 32 ' - 9 " 32 ' - 2 " 35 ' - 1 " 5' - 4" 19' - 1" 8' - 4" 6' - 4" 27' - 5" 5' - 7" 41' - 8"19' - 6" 5' - 7" 36' - 4"4' - 0" 6' - 0 " 11' - 10"9' - 2" 1 2 ' - 9 " (N)ADU 749 SQ.FT. 8' - 0 " 25 ' - 0 " 6' - 0 " 13' - 7"11' - 0" (E)PORCH 50 SQ.FT. NON-SPRINKLERED 1 6 ' - 5 " (N)HEAT PUMP SYSTEM 28" H X 36" W X 15" D Heating 9.5 min HSPF Cooling 18 min SEER (N) LANDSCAPE (N)NEEA HEAT PUMP WATER HEATER 50 min TANK GALLON (N)GAS LINE 1" DIAM CONNECT TO EXISTING (N)SUB-PANEL 100 AMPS (N ) S E W E R L I N E 4 " D I A M CO N N E C T T O E X I S T I N G (E)WATER METER (N ) W A T E R L I N E 1 " D I A M CO N N E C T T O E X I S T I N G (N) PORCH3' - 0 " 5' - 0" 5' - 0 " IMAGINARY PROPERTY LINE 3' - 0 " (E)ELECTRIC METER NOTE: Type 1 surge-protective device (SPD) shall be installed PROPERTY LINE 72' PROPERTY LINE 72' PR O P E R T Y L I N E 1 0 0 ' PR O P E R T Y L I N E 1 0 0 ' (E) SFD 2- STORY 2,680 SQ.FT. (E)DRIVEWAY (E)BACK YARD (E)FRONT YARD (E)PAVEMENT (E ) S I D E Y A R D (E)BACK YARD (E ) D R I V E W A Y (E)ELECTRIC METER (E ) W A T E R HE A T E R (E)GAS METER (E)GARAGE 440 SQ.FT. (E) SIDEWALK (E) PARKWAY CLEMENSEN AVE 25 ' - 2 " 22 ' - 2 " 1 7 ' - 7 " 32 ' - 9 " 32 ' - 2 " 35 ' - 1 " 5' - 4" 19' - 1" 8' - 4" 6' - 4" 27' - 5" 5' - 7" 41' - 8"19' - 6" 5' - 7" (E)PORCH 50 SQ.FT. NON-SPRINKLERED (E ) D R A I N 2% S L O P E (E ) D R A IN 2% S L O P E (E ) D R A I N 2% S L O P E (E ) D R A I N 2% S L O PE (E)UNPERMITTED STRUCTURE TO BE DEMOLISHED 175 SQ.FT. 7' - 0 " 25' - 0" Scale Project number Date Drawn by Owner Project Address Phone 1/8" = 1'-0" A-0 PLOT PLAN 37-23 NANCY CALTAGIRONE 08/2024 J.P. Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 613 S EASTBURY AVE, COVINA CA 91723 PROJECT INFORMATION Assessor's ID No.: 390-184-02 Site Address: Main House: 1506 CLEMENSEN AVE SANTA ANA CA 92705 ADU: 1506 CLEMENSEN AVE # 2 SANTA ANA CA 92705 Tract: N-TRACT: 4977 BLOCK: LOT: 2 Zone: R1 Lot Size: 7,199 SQ.FT. Type of Construction V-B Occupancy Group: R-3 Number of stories (E)SFD:2-Story Number of stories (N)ADU:1-Story Height (E)SFD: <25' Height (N)ADU: 12'-9" Fire Sprinklers: NO Flood Zone: "X" SCOPE OF WORK - NEW DETACHED 1-STORY ACCESSORY DWELLING UNIT WITH PORCH. - EXISTING UNPERMITTED STRUCTURE TO BE DEMOLISHED PROJECT SUMMARY -(E)First Floor 1,290 SQ.FT. -(E)Second Floor 874 SQ.FT. -(E)GARAGE 440 SQ.FT. -(E)PORCH 50 SQ.FT. -(N)DETACHED ADU 749 SQ.FT. -(N)OVERHANG PORCH 15 SQ.FT. TOTAL 3,418 SQ.FT. LOT COVERAGE: 1,290 (First Floor)+440 (Garage)+50(Porch)+749 (ADU)+15(Porch)= 2,544 SQ.FT. 2,544/7,199= 35.3 % Park & Rec Development fee calculation (N)ADU 749 SQ.FT. (E)SFD 2,680 SQ.FT. Calculation: 749/2,680=27.9 VICINITY MAP INDEX A-0 EXISTING AND PROPOSED SITE PLAN A-0.1 GENERAL NOTES A-1.1 GREEN BUILDING FORMS A-1.2 GREEN BUILDING FORMS A-1.3 BEST MANAGMENT PRACTICES A-2 EXISTING FLOOR PLAN AND ROOF PLAN - Main House A-3 EXISTING EXTERIOR ELEVATIONS - Main House A-4 EXISTING EXTERIOR ELEVATIONS - Main House A-5 PROPOSED FLOOR PLAN - ADU A-6 EXTERIOR ELEVATIONS - ADU A-7 PROPOSED ROOF PLAN, SECTION & ARCHITECTURAL DETAILS -ADU S1 STRUCTURAL NOTES S2 FOUNDATION AND ROOF FRAMING PLAN S3 STRUCTURAL DETAILS S4 STRUCTURAL DETAILS S5 STRUCTURAL DETAILS 1 TITLE 24 2 TITLE 24 3 TITLE 24 TS1 BOUNDARY & TOPOGRAPHIC SURVEY G1 DRAINAGE PLAN PROPOSED SITE PLAN ESC 1/8"=1'-0" 1. THIS PROJECT SHALL COMPLY WITH TITLE 24 AND 2022 CALIFORNIA RESIDENTIAL CODE (CRC) CALIFORNIA BUILDING CODE (CBC) CALIFORNIA MECHANICAL CODE (CMC) CALIFORNIA PLUMBING CODE (CPC) CALIFORNIA ELECTRICAL CODE (CEC) CALIFORNIA ENERGY CODE CALIFORNIA GREEN BUILDING CODE SANTA ANA MUNICIPAL CODE 714-997-0313 PROJECT LOCATION TRANSIT AVAILABLE @ 0.3 MILES NO PARKING REQUIRED PROJECT LOCATION EXISTING SITE PLAN ESC 1/8"=1'-0" No. Description Date 1 Revision 1 Date 1 CITY REQUIRED NOTE: The ADU sf / SFD sf ratio is for Park & Rec fee purpose only. The applicant is responsible for the given “SFR sf”of the existing primary residence; Building Safety staff are not responsible for the accuracy of the given “SFR sf”of the existing residence. NOTE: “DEFERRED SUBMITTALS TO BE REVIEWED BY PROJECT ARCHITECT OR ENGINEER OF RECORD AND CERTIFIED PRIOR TO SUBMITTAL FOR PLAN REVIEW.” PROJECT TEAM OWNER: NANCY CALTAGIRONE nancycmft@gmail.com 714-997-1313 ARCHITECT: GLEN SALCEDO charles@gcharlesdesign.com 818.578.5895 ENGINEER: STEN ENGINEERING EVGENY NAGOVITSYN info@stenengineering.com 323.486.4151 DRAFTING: MILA DRAFTING INC JENNY PARADA miladraftinginc@gmail.com 626-347-9230 ENERGY CALCULATIONS: PERFECT DESIGN RAYMOND ZHONG perfectaaa2@gmail.com 626.289.8808 CODES: BLDG# 101119244 APPROVALS BLDG- CSG Consultants PLNG- ASevilla POLICE- BMartin 1506 E Clemensen Ave & #212/12/2024 1. WHERE CONCEALED DUCT RUNS IN SOFFITS, JOIST BAYS, VERTICAL CHASES, OR SHAFTS ARE OBSTRUCTED TO LESS THAN THE MINIMUM REQUIRED TO ALLOW THE PASSAGE OF INDICATED ROUND DUCT, PROVIDE RECTANGULAR DUCTWORK OF EQUIVALENT SIZE TO ALLOW PASSAGE OF THE DUCT RUN PAST THE OBSTRUCTION. 2. AN APPROVED SEISMIC GAS SHUTOFF VALVE SHALL BE INSTALLED ON THE FUEL GAS LINE ON THE DOWN STREAM SIDE OF THE UTILITY METER AND BE RIGIDLY CONNECTED TO THE EXTERIOR OF THE BUILDING OR STRUCTURE CONTAINING THE FUEL GAS PIPING. 3. DRAWING SYMBOL REFERENCES ARE TYPICAL AND APPLY EQUALLY TO ALL SIMILAR CONDITIONS UNLESS OTHERWISE NOTED OR OTHERWISE REFERENCED IN THE DESIGN DRAWINGS. SEE THE SYMBOLS' LEGEND ON EACH SHEET FOR DEFINITION OF ALL SYMBOLS USED IN THE DRAWINGS. 4. DETAIL REFERENCES ARE TYPICAL AND APPLY EQUALLY TO OTHER SIMILAR CONDITIONS UNLESS OTHERWISE NOTED OR OTHERWISE REFERENCED IN THE DESIGN DRAWINGS. DO NOT DISREGARD UNREFERENCED OR MISREFERENCED DETAILS. SUCH DETAILS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND/OR OWNER FOR INTERPRETATION OF APPLICABILITY & USAGE. 5. DO NOT SCALE DRAWINGS. 6.ALL DIMENSIONS SHALL BE VERIFIED IN FIELD. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND/OR OWNER PRIOR TO PUTTING ANY AFFECTED WORK IN PLACE. 7. WOOD FRAMED BUILDINGS: ALL EXTERIOR WALL DIMENSIONS ARE TO FACE OF WOOD (FRAMING OR PLYWOOD SHEATHING WHERE OCCURS) UNLESS NOTED OTHERWISE. ALL INTERIOR WALL DIMENSIONS ARE TO FACE OF FRAMING UNLESS NOTED OTHERWISE. DIMENSIONS NOTED OTHERWISE MAY BE NOTED AS ONE OF THE FOLLOWING: C.L. CENTERLINE F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.M. FACE OF MASONRY CLR. FACE OF FINISH AND/OR OBSTRUCTION 8. ALL FINISHED GRADE AREAS AROUND BUILDINGS SHALL SLOPE AWAY FROM BUILDINGS AT 2% MINIMUM. 9. PLUMBING FIXTURES ARE REQUIRED TO BE CONNECTED TO A SANITARY SEWER OR AN APPROVED SEWAGE DISPOSAL SYSTEM. 10. KITCHEN SINKS, LAVATORIES, BATHTUBS, SHOWERS, BIDETS, LAUNDRY TUBS & WASHING MACHINE OUTLETS SHALL BE PROVIDED WITH HOT & COLD WATER & CONNECTED TO AN APPROVED WATER SUPPLY. 11. BATHTUB & SHOWER FLOORS, WALLS ABOVE THE BATHTUBS WITH A SHOWERHEAD & SHOWERS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACE SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 72" ABOVE THE FLOOR. 12. PROVIDE A MINIMUM 70" HIGH APPROVED NON-ABSORBANT, SHATTER-RESISTANT MATERIAL FOR SHOWER ENCLOSURES. 19B. VERTICAL DIMENSIONS ARE FROM TOP OF CONCRETE SLAB TO TOP OF PLATE AND FROM TOP OF PLYWOOD FLOOR SHEATHING TO TOP OF PLATE UNLESS OTHERWISE NOTED OR CALLED OUT IN THE DRAWINGS. THE TERM "FINISH FLOOR" EXCLUDES ANY FLOORING MATERIALS THAT MAY BE SCHEDULED AND MEANS THE TOP OF THE FINISHED CONSTRUCTION THAT IS TO RECEIVE THE FLOORING MATERIALS SUCH AS TOP OF LEVEL CONCRETE SLAB OR TOP OF LEVEL LIGHT WEIGHT FLOOR TOPPING. 20. VERIFY ALL BUILT-IN EQUIPMENT SIZES AND REQUIREMENTS PRIOR TO LAYOUT AND CONSTRUCTION. BUILT-IN EQUIPMENT SHALL FIT TIGHTLY AS POSSIBLE WITHIN MANUFACTURER'S REQUIRED TOLERANCES TO FINISHED OPENING. 21. HANDRAIL ASSEMBLIES AND GUARDS SHALL BE ABLE TO RESIST A SINGLE CONCENTRATED LOAD OF 200 LBS. APPLIED IN ANY DIRECTION AT ANY POINT ALONG THE TOP, AND HAVE ATTACHMENT DEVICES AND SUPPORTING STRUCTURE TO TRANSFER THIS LOADING TO APPROPRIATE STRUCTURAL ELEMENTS OF THE BUILDING PER 1607.7.1 AND 1607.7.1.1. 22. ALL CONCRETE SURFACES SHALL HAVE A LIGHT BROOM FINISHED, NON-SLIP SURFACE UNLESS NOTED OTHERWISE. 23. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS. 24.ALL PIPING IN CONNECTION WITH A PLUMBING SYSTEM SHALL BE SO INSTALLED THAT PIPING OR CONNECTIONS WILL NOT BE SUBJECT TO UNDUE STRAINS OR STRESSES, AND PROVISIONS SHALL BE MADE FOR EXPANSION, CONTRACTION, AND STRUCTURAL SETTLEMENT. NO PIPING SHALL BE DIRECTLY EMBEDDED IN CONCRETE OR MASONRY. NO STRUCTURAL MEMBER SHALL BE SERIOUSLY WEAKENED OR IMPAIRED BY CUTTING, NOTCHING OR OTHERWISE. 25. AT LOCATIONS TO RECEIVE BUILT-IN CASEWORK, FIELD VERIFY ALL CLEAR OPENINGS OF CONSTRUCTION AND ADDRESS IN SHOP DRAWINGS BEFORE FABRICATION OF CASEWORK. 26. VERIFY ALL EQUIPMENT SIZES BEFORE FABRICATION OF CASEWORK. RESIDENTIAL-TYPE AND BUILT-IN KITCHEN EQUIPMENT/APPLIANCES (REFRIGERATOR, RANGE, MICROWAVE, ETC.) AND ALL OTHER BUILT-IN TYPE EQUIPMENT SHALL FIT TIGHTLY AS POSSIBLE WITHIN EQUIPMENT/ APPLIANCE MANUFACTURER'S REQUIREMENTS TO CASEWORK OPENINGS. 27. CASEWORK SHALL BE PROVIDED WITH REQUIRED HOLES, AND ACCESS PANELS FOR ELECTRICAL CABLES, PIPES, AND LIKE PENETRATING ITEMS. 28. IN NEW CONSTRUCTION CARBON MONOXIDE/SMOKE DETECTORS SHALL RECEIVE THEIR PRIMARY POWER SOURCE FROM THE BUILDING WIRING & SHALL BE EQUIPPED WITH BATTERY BACK UP & LOW BATTERY SIGNAL. SMOKE ALARMS SHALL BE LOCATED IN EACH SLEEPING ROOM, HALLWAY OR AREA GIVING ACCESS TO A SLEEPING ROOM, AND ON EACH STORY AND BASEMENT FOR DWELLINGS WITH MORE THAN ONE STORY. DETECTORS SHALL BE INTERCONNECTED SO THAT ACTUATION OF ONE ALARM WILL ACTIVATE ALL THE ALARMS WITHIN THE INDIVIDUAL DWELLING UNIT. 29. STORAGE TYPE WATER HEATERS SHALL BE STRAPPED TO THE WALL (INTO 2x BLOCKING), PER CODE. 30. BUILDING SHALL HAVE APPROVED ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVED BUILDING IDENTIFICATION PLACED IN A POSITION THAT IS PLAINLY LEGIBLE & VISIBLE FROM THE STREET OR ROAD FRONTING THE PROPERTY. 31. DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM No.26 GAUGE SHEET STEEL OR OTHER APPROVED MATERIAL & THERE SHALL BE NO OPENINGS FROM THE DUCT INTO THE GARAGE. 32. OTHER PENETRATIONS OF GARAGE/DWELLING CEILINGS & WALLS ARE TO BE PROTECTED AS REQUIRED FOR ONE HOUR ASSEMBLY 33. HEATER SHALL BE CAPABLE OF MAINTAINING A MINIMUM ROOM TEMPERATURE OF 68°F AT A POINT 3' ABOVE THE FLOOR 7 2' FROM EXTERIOR WALLS IN ALL HABITABLE ROOMS AT THE DESIGN TEMPERATURE. ENERGY AND WATER CONSERVATION 1. CAULK AND SEAL AROUND ALL PLUMBING AND ELECTRICAL PENETRATIONS INTO THE BUILDING ENVELOPE. 2. CAULK AND SEAL AROUND ALL WINDOW AND DOOR FRAMES, BETWEEN WALL SOLE PLATES AND FLOORS, AND BETWEEN EXTERIOR WALL PANELS. SEE TYPICAL EXTERIOR WALL MEASURES. 3. ALL INSULATION MATERIALS SHALL BE CERTIFIED BY THE MANUFACTURER AS COMPLYING WITH THE CALIFORNIA QUALITY STANDARDS FOR INSULATING MATERIAL. 4. DOORS AND WINDOWS BETWEEN CONDITIONED SPACE AND OUTSIDE SPACE OR BETWEEN CONDITIONED SPACE & UNCONDITIONED SPACE SHALL BE FULLY WEATHER-STRIPPED. 5. MANUFACTURED DOORS AND WINDOWS SHALL BE CERTIFIED AND LABELED IN COMPLIANCE WITH THE APPROPRIATE INFILTRATION STANDARDS. ALL EXTERIOR OPENINGS SHALL BE PROPERLY WEATHERSTRIPPED, CERTIFIED, AND LABELED. 6. DUCTS SHALL BE CONSTRUCTED, INSTALLED, AND INSULATED PER THE REQUIREMENTS OF THE U.M.C. ALL JOINTS OF THE DUCT SYSTEM SHALL BE TIGHTLY SEALED WITH MASTIC OR TAPE SUITABLE FOR THE PURPOSE. 7. ALL SPACE CONDITIONING EQUIPMENT SHALL BE C.E.C. CERTIFIED. 8.ALL WATER HEATING EQUIPMENT, SHOWER HEADS, FAUCETS, AND PLUMBING FIXTURES SHALL BE C.E.C. CERTIFIED UNLESS OTHERWISE NOTED OR APPROVED. SHOWER HEADS SHALL BE LOW FLOW TYPE. 9. GENERAL LIGHTING IN KITCHENS AND BATHROOMS SHALL HAVE A MINIMUM OF 40 LUMENS/WATT EFFICIENCY (FLUORESCENT LIGHTS OR LED WITH 3000 KELVIN MAX). 10. PROVIDE ULTRA FLUSH WATER CLOSETS FOR ALL NEW CONSTRUCTION. EXISTING SHOWER HEADS AND TOILETS MUST BE ADAPTED FOR LOW WATER CONSUMPTION. SCHEDULE IS IMPACTED BY OWNER RELATED CHANGES OR REQUESTS. AT THE TIME OF PRICING & PROIR TO CONSTRUCTION PROCEEDING. THAT ALL REQUIRED CLEARANCE FOR INSTALLATION AND TO INCLUDE ALL PIPING, DUCT WORK AND CONDUITS) LIGHTING, PLUMBING AND SPRINKLER EQUIPMENT OF ANY AND ALL MECHANICAL, TELEPHONE, ELECTRICAL, ANY CONFLICTS PRIOR TO CONSTRUCTION THAT EXIST IN LOCATIONS 3. GENERAL CONTRACTOR SHALL INFORM ARCHITECT OF PROCEEDING WITH WORK OR RELATED WORK IN QUESTION. OBTAINING A CLARIFICATION FROM ARCHITECT BEFORE QUESTIONS, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR QUESTIONS REGARDING THESE OR OTHER COORDINATION BEFORE PROCEEDING WITH CONSTRUCTION. IF THERE ARE ANY ACCURACY AND CONFIRMING WORK IS BUILDABLE AS SHOWN CONTRACT DOCUMENTS, FIELD CONDITIONS AND DIMENSIONS FOR 1. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR CHECKING MAINTENANCE OF ABOVE EQUIPMENT ARE PROVIDED. AND DETAILS. CONNECTION WITH THE WORK. REQUIREMENTS. CONTRACTORS WORK. DISCIPLINE OF ALL WORKERS ON THE PROJECT. ALL OVERTIME COSTS EXCEPT WHEN THE APPROVED CONSTRUCTION 4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING DOCUMENTS SHALL BE FURNISHED AND INSTALLED IN 6. ALL WORK NOT SPECIFICALLY COVERED IN THE CONSTRUCTION MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS IN GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR INITIATING, PROPERTY DAMAGE FOR THE LIMITS AS REQUIRED BY LAW. THE RESPECT TO WORKMAN'S COMPENSATION, PUBLIC LIABILITY AND PURCHASE AND MAINTAIN CERTIFICATIONS OF INSURANCE WITH 5. THE GENERAL CONTRACTOR AND SUBCONTRACTORS SHALL REGULATORY AGENCIES, APPLICABLE BUILDING CODES AND ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL LOCAL 13. GENERAL CONTRACTOR SHALL HAVE ON-SITE, THE APPROVED AND THE OBTAINING OF A FINAL CERTIFICATE OF OCCUPANCY. DEPARTMENT INSPECTIONS AND APPROVALS IN ALL FIELDS OF HIS WORK, OF WORK, THE REQUESTING AND COORDINATION OF BUILDING REQUIRED PERMITS PRIOR TO COMMENCEMENT 12. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL SECURITY OF PROJECT AND SHALL BE RESPONSIBLE FOR 11. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR 8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ANY AND CONSTRUCTION TIME FOR ALL SUBCONTRACTORS AND GENERAL SPECIFIC CONSTRUCTION SCHEDULE INDICATING THE REQUIRED CONTRACTOR SHALL ALSO SUBMIT A SCHEDULE OF VALUES AND A 7. UPON SUBMITTAL OF CONSTRUCTION COSTS, THE GENERAL ACCORDANCE WITH BUILDING STANDARD MATERIALS PERSONNEL.) CONSTRUCTION DRAWINGS AND BUILDING PERMIT. ASSISTANCE AND COORDINATION OF VARIOUS TRADES. COMPLETION. SUCH INSTALLATION. JOB INCLUDING REVISIONS. CONTRACTOR SHALL COORDINATE AND COOPERATE TO EFFECT AND/OR EQUIPMENT SHALL BE PROVIDED BY OTHERS. 15. WHERE WORK OR EQUIPMENT IS INDICATED N.I.C., SUCH WORK SHALL SUBMIT CERTIFICATES OF INSPECTION OF SATISFACTORY 20. UPON COMPLETION OF THE JOB, THE GENERAL CONTRACTOR RESPONSIBILITY AT ALL TIMES DURING THE PROGRESS OF THE DRAWINGS TO ALL TRADES FALLING UNDER THEIR CONTRACTOR TO DISTRIBUTE ADEQUATE COPIES OF ALL 19. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL AND NOTIFICATION SHALL BE MADE PRIOR TO INSTALLATION. USED, IT SHALL BE BY JUDGEMENT AND APPROVAL OF THE ARCHITECT MANUFACTURERS ARE SPECIFIED. WHERE APPROVED EQUAL IS SUBSTITUTIONS FOR ANY MATERIAL WHERE SPECIFIC 18. THE CONTRACTOR SHALL NOTE THAT THERE SHALL NOT BE CUTTING AND RUBBISH REMOVAL WITH BUILDING MANAGEMENT BUILDING MANAGEMENT PERSONNEL. (I.E.: DEMOLITION, 17. GENERAL CONTRACTOR SHALL COORDINATE ANY OVERTIME WITH 14. THE GENERAL CONTRACTOR SHALL PROVIDE ALL SUPERVISION, BROUGHT TO THE ATTENTION OF THE ARCHITECT & THE OWNER 16. DISCREPANCIES FOUND BETWEEN NOTES AND DRAWINGS SHALL BE GENERAL NOTES - PART B FURTHERMORE, FOR EXISTING CONDITIONS ON REMODEL/ADDITIONS, THE ARCHITECT CANNOT REALISTICALLY VERIFY ALL EXISTING CONDITIONS ACCURATELY. AS SUCH THE PREPARATION OF CONSTRUCTION DOCUMENTS ARE BASED ON TYPE V WOOD FRAME CONSTRUCTION FOR CONVENTIONAL FRAMING AND WHERE THE GENERAL CONTRACTOR MAY DISCOVER SOME DISCREPANCIES IN THE ARCHTIECT AND ENGINEERS DESIGN WITH RESPECT TO THE NEW FOUND EXISTING CONDITIONS ON SITE. THESE DISCPREPANCIES ARE EXPECTED AND A NATURAL PROCESS BECAUSE ARCHITECTURE SERVICES PRECEDES DEMOLITION OF THE PROJECT. GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER IF ANY OF THE DESIGN IS IN CONFLICT WITH THE EXISTING CONDITIONS. 10.NOT USED THESE ARE GENERAL NOTES AND SOME ITEMS MAY NOT APPLY TO THE SPECIFIC SCOPE. G.C. SHALL IN THE BEST OF JUDGEMENT, APPLY ITEMS THAT ARE RELEVANT TO THE SCOPE DISPLAYED IN THE DRAWINGS. FOR REMODELS/ADDITIONS, IN CASES WHERE A LAND SURVEY WAS NOT PERFORMED EITHER BECAUSE IT WAS NOT REQUIRED AND/OR CLIENT HAS NOT ELECTED TO FURNISH A SURVEY, ARCHITECT SHALL BASE SITE PROPERTY MEASUREMENTS FROM PERCEIVED PROPERTY LINES REPRESENTED BY FENCES, WALLS AND PLANTINGS. EVERY EFFORT WILL BE MADE TO PROVIDE AN ACCURATE MEASUREMENT HOWEVER SUCH MEASUREMENT CANNOT GUARANTEE ACCURACY DURING CONSTRUCTION. AS SUCH, IT IS UNDERSTOOD BY ALL PARTIES, OWNER, ARCHITECT, AND GENERAL CONTRACTOR, THAT DISCREPANCIES ARE POSSIBLE AND AT NO FAULT TO ANY PARTY. CLIENT MAY INCUR A MINOR CHANGE ORDER DUE TO THIS EVENT DUE TO ADJUSTMENTS IN THE DESIGN AFTER PERMIT. MATERIAL SPECIFICATIONS G.CHARLES DESIGN OFFERS ARCHITECTURE SERVICES WHERE A MAJORITY OF THE PACKAGES ARE BASED ON 'MINIMALLY TO PROCURE A BUILDING PERMIT'. THE PACKAGES ARE BASED ON THE MINIMUM REQUIREMENTS OF THE BUILDING CODES IN PLACE AT EACH JURISDICTION AND WHICH ARE LARGELY BASED ON MAINTAINING PUBLIC SAFETY. BECAUSE OUR CONSTRUCTION DRAWING PACKAGES ARE BASED ON MINIMUM REQUIREMENTS ESTABLISHED BY EACH BUILDING DEPARTMENT, OUR DETAILS ARE GENERAL AND MAY BE ADAPTED AND/OR APPLIED TO A VARIETY OF FIELD CONDITIONS. IN SOME CASES, OUR DRAWINGS WILL INDICATE MATERIAL SPECIFICATIONS FOR ITEMS SUCH AS WATER PROOF MEMBRANES THAT HELP PROTECT FROM WATER PENETRATION. IF SUCH ITEMS ARE NOT FOUND IN OUR SHEET SET, OR ARE UNCLEAR, THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT TO REQUEST A DETAIL AND/OR A SPECIFICATION. IN ALL CIRCUMSTANCES, THE GENERAL CONTRACTOR SHALL UTILIZE GOOD JUDGEMENT OF THE INSTALLATION OF VARIOUS MATERIALS. AS SUCH, ALL INSTALLATIONS SHALL BE COMPLETED WITH STRICT CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS, WRITTEN INSTRUCTIONS, INDUSTRY STANDARDS, AND BUILDING CODES. GCD 2018 GENERAL NOTES - PART A / MEANS METHODS SEQUENCES, AND TECHNIQUE 21. WORK SHALL COMPLY WITH ALL LAWS, RULES AND REGULATIONS AS REQUIRED BY THE STATE OF CALIFORNIA, THE COUNTY OF LOS ANGELES, THE CITY OF LOS ANGELES, AND ANY AND ALL OTHER GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER THE WORK. THIS WILL APPLY TO ANY OTHER JURISDICTIONS SPECIFIC TO THE PROJECT SITE LOCATION OUTSIDE OF THE GREATER COUNTY OF LOS ANGELES. 22. WORK SHALL COMPLY WITH THE MODEL CODES AS ADOPTED BY LOCAL JURISDICTION, TO INCLUDE, BUT NOT LIMITED TO, (CITY OF LOS ANGELES BUILDING CODE, CALIFORNIA BUILDING CODE, INTERNATIONAL BUILDING CODE, CALIFORNIA RESIDENTIAL CODE, CALIFORNIA GREEN BUILDING STANDARDS, UNIFORM MECHANICAL CODE, UNIFORM PLUMBING CODE, NATIONAL ELECTRICAL CODE, ETC.) LOCALLY IN FORCE AT THE TIME OF BUILDING PERMIT ISSUANCE, INCLUDING ALL REVISIONS AND AMENDMENTS ADOPTED BY THE GOVERNING JURISDICTION(S). WHERE REFERENCE IS MADE TO MODEL CODE SECTIONS AND PARTS, THE CONTRACTOR SHALL BECOME FAMILIAR WITH THE MODEL CODE SECTIONS AND PARTS CITED PRIOR TO INSTALLATION OF ANY AFFECTED WORK. 23. FULLY REVIEW THE ENTIRE SET OF CONSTRUCTION DOCUMENTS PRIOR TO CONSTRUCTION. THE CONSTRUCTION DOCUMENTS MAY INCLUDE THE FOLLOWING: CIVIL DRAWINGS, DESIGN DRAWINGS, STRUCTURAL DRAWINGS, MECHANICAL DRAWINGS PLUMBING DRAWINGS, ELECTRICAL DRAWINGS, SECURITY SYSTEM DRAWINGS AND SPECIFICATIONS (DEFERRED SUBMITTAL), FIRE PROTECTION SHOP DRAWINGS AND SPECIFICATIONS (DEFERRED SUBMITTAL) 24. WHERE CONFLICT OCCURS BETWEEN THE DRAWINGS OF ANY OF THE DESIGN DISCIPLINES INVOLVED, THE MOST RESTRICTIVE INTERPRETATION WILL GOVERN THE WORK. ARCHITECT AND/OR OWNER WILL RESOLVE DESIGN CONFLICTS BASED ON THE DESIGN INTENT. 25. COORDINATE ALL CHANGES AND ADJUSTMENTS TO THE WORK WHICH VARY FROM THE CONSTRUCTION DOCUMENTS WITH ARCHITECT AND/OR PRIOR TO PUTTING WORK IN PLACE. 26. ALL PRODUCT AND COMPONENT BRANDS AND TRADEMARKS NAMED ARE USED TO SET THE LEVEL OF QUALITY REQUIRED FOR THE WORK AND ARE UNDERSTOOD TO BE "OR EQUAL" REFERENCES SUBJECT TO THE FORMAL APPROVAL PROCESS AS DESCRIBED AND SET FORTH IN THE SPECIFICATIONS UNLESS NOTED OTHERWISE. 27.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK, USING CONTRACTOR'S BEST SKILL AND ATTENTION. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR, AND HAVE CONTROL OVER, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT, UNLESS THE CONTRACT DOCUMENTS GIVE OTHER SPECIFIC INSTRUCTIONS CONCERNING THESE MATTERS. 13. MATERIAL SHALL BE JOINED TO UNIFORM, ACCURATE FITS SO THEY MEET WITH NEAT, STRAIGHT LINES, FREE OF SMEARS, OVERLAPS AND IMPERFECTIONS. INSTALL EXPOSED MATERIALS . APPROPRIATELY LEVEL, PLUM AND AT RIGHT ANGLES OR FLUSH WITH ADJOINING MATERIALS. WORK OF EACH TRADE SHALL MEET OR EXCEED ALL NATIONAL STANDARDS PUBLISHED BY THAT TRADE EXCEPT WHERE THE CONTRACT DOCUMENTS ARE MORE STRINGENT. IN SUCH CASES, WORK SHALL MEET OR EXCEED THE STANDARDS ESTABLISHED BY THE CONTRACT DOCUMENTS. 14.THE CONTRACTOR SHALL , AT ALL TIMES, KEEP PREMISES FREE FROM ACCUMULATION OF DEBRIS CAUSED BY HIS OPERATIONS/WORK. 15.THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING ANY DEFECTS FOUND IN EXISTING BASE BUILDING CONSTRUCTION WHICH INTERFACES WITH NEW CONSTRUCTION. THIS INCLUDES BUT IS NOT LIMITED TO, UNEVEN SURFACES AND FINISHES AT PLASTER OR GYPSUM BOARD. THE GENERAL CONTRACTOR SHALL PATCH AND REPAIR SURFACES TO MATCH ADJACENT ADJOINING SURFACES. 28.CONTRACTOR MAY MAKE MINOR CHANGES IN THE WORK AUTHORIZED BY THE ARCHITECT IN ACCORDANCE THE SPECIFICATIONS AND SUBMITTALS. THE CONTRACTOR MAY MAKE SUBSTITUTIONS ONLY WITH THE CONSENT OF THE OWNER, AFTER EVALUATION BY THE ARCHITECT AND IN ACCORDANCE WITH A CHANGE ORDER OR CHANGE DIRECTIVE. 16. GENERAL CONTRACTOR TO VERIFY SIZES OF BUILDING ACCESS OPENINGS BEFORE PROCEEDING WITH WORK. 17.UPON COMPLETION OF THE JOB, GENERAL CONTRACTOR SHALL CLEAN ENTIRE AREA , INCLUDING GLASS, CARPET, AND ALL OTHER FINISHED SURFACES IN A MANNER ACCEPTABLE TO OWNER. 18.GENERAL CONTRACTOR IS RESPONSIBLE FOR DISPOSING OF OFF SITE PACKAGING CARTONS OR CONTAINERS, TRASH AND DEBRIS IN A SAFE, ACCEPTABLE MANNER, AND TO NO COST OR INCONVENIENCE TO OTHER PARTIES. 19.GENERAL CONTRACTOR SHALL PROVIDE PROTECTIVE COVERINGS FOR CARPET, FURNISHINGS AND EXISTING FINISHES IN AREAS OF DEMOLITION AND CONSTRUCTION AND SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY THE WORK OF THE GENERAL CONTRACTOR AND ANY SUBCONTRACTOR. CONSTRUCTION SITE PROTOCOL FOR GENERAL CONTRACTOR CONTRACTOR IS RESPONSIBLE FOR HAVING THE ORIGINAL APPROVED SET ON SITE AT ALL TIMES, AND ANY COPIES ARE REQUIRED TO BE FROM THE ORIGINAL FINAL SET OF PLANS. CONTRACTOR SHOULD NOT UN-STAPLE ANY BINDED SETS. 9.NOT USED Scale Project number Date Drawn by A-0.1 GENERAL NOTES 37-23 08/2024 JENNY PARADA 613 S EASTBURY AVE, COVINA CA 91723 No.Description Date jenny_parada@verizon.net Owner Address NANCY CALTAGIRONE Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 PHONE: 714-997-0313 1506 E Clemensen Ave & #212/12/2024 UP (E)BEDROOM (E)LIVING ROOM (E)DINING ROOM (E)KITCHEN (E)GARAGE (E)BATHROOM (E)CLOSET (E)CL (E)CL (E)CL (E)CL (E)FAMILY ROOM (E)HALLWAY (E)FOYER REF 32 ' - 2 " 61' - 2" 41' - 8"19' - 6" 22 ' - 2 " 17 ' - 7 " 39 ' - 9 " (E)BEDROOM (E)BEDROOM (E)BEDROOM (E)BATHROOM (E)BATHROOM (E)CL (E)CL (E)CL (E)CL (E ) H A L L W A Y (E)FIRST FLOOR LINE DOWN EXISTING ASPHALT SHINGLE ROOF CLASS A 3:12 ROOF PITCH N1 N1 N1 N1 N1 N1N1 N1 N1 N1 N1 N1 Scale Project number Date Drawn by Owner Project Address Phone As indicated A-2 EXISTING FLOOR PLAN 37-23 NANCY CALTAGIRONE 04/2024 JENNY PARADA Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 613 S EASTBURY AVE, COVINA CA 91723 LEGEND (E)STUD TO REMAIN EXISTING FLOOR PLAN - First Level ESC 1/4"=1'-0" EXISTING FLOOR PLAN - Second Level ESC 1/4"=1'-0" MAIN HOUSE EXISTING ROOF PLAN ESC 3/16"=1'-0" No. Description Date 714-997-0313 1506 E Clemensen Ave & #212/12/2024 (E)STUC C O 8' - 0 " 1' - 0 " 8' - 0 " (E)STUC C O (E)ASPHALT SHIN G L E ROOF (E)ASPHALT SHIN G L E ROOF (E)ASPHALT SHIN G L E ROOF (E)BRIC K VENEER (E)ASPHALT SHIN G L E ROOF (E)STUC C O (E)STUC C O (E)STUC C O (E)ASPHALT SHIN G L E ROOF (E)ASPHALT SHIN G L E ROOF Scale Project number Date Drawn by Owner Project Address Phone 1/4" = 1'-0" A-3 EXISTING ELEVATIONS 37-23 NANCY CALTAGIRONE 04/2024 JP Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 613 S EASTBURY AVE, COVINA CA 91723 ESC 1/4"=1'-0" ESC 1/4"=1'-0" EXISTING SOUTH ELEVATION EXISTING NORTH ELEVATION MAIN HOUSE No. Description Date 714-997-0313 1506 E Clemensen Ave & #212/12/2024 (E)ASPHALT SHIN G L E ROOF (E)STUC C O (E)ASPHALT SHIN G L E ROOF 8' - 0 " (E)ASPHALT SHIN G L E ROOF (E)ASPHALT SHIN G L E ROOF (E)STUC C O (E)STUC C O 8' - 0 " Scale Project number Date Drawn by Owner Project Address Phone 1/4" = 1'-0" A-4 EXISTING ELEVATIONS 37-23 NANCY CALTAGIRONE 04/2024 JP Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 613 S EASTBURY AVE, COVINA CA 91723 ESC 1/4"=1'-0" ESC 1/4"=1'-0" EXISTING EAST ELEVATION EXISTING WEST ELEVATION MAIN HOUSE No. Description Date 714-997-0313 1506 E Clemensen Ave & #212/12/2024 4 C SA 3S D SA CO N5 (N ) 5 / 8 " G Y P S U M B O A R D T Y P E " X " A-7 1 GFCI 160 CFM MIN NON-RECIRCULING EXHAUST FAN TO OUTSIDE 12' - 3" 10 ' - 0 " 5' - 0 " 16 ' - 5 " 12' - 0" 10 ' - 0 " REF GREAT ROOM 300 SQ.FT. CL BATHROOM BEDROOM 120 SQ.FT. MASTER BEDROOM 122.5 SQ.FT. BATHROOM CL 2' - 0" 5' - 0 " 13' - 7"11' - 0"11' - 10" 25 ' - 0 " 36' - 4" 9' - 9 " 3' - 1 1 " 4' - 9 " 8' - 3" 2' - 0"8' - 0" 2' - 0 " 8' - 0" 3' - 0" 15"min B 1 2 22 2 2 3 5' - 7"5 3 3 A C D W D 3' - 0"5' - 0"3' - 0" 16 ' - 3 " 10' - 10" 26' - 9" A-7 3 1.5" MAXø 2' - 6" MIN15"MIN 15"MIN 24 " M I N 1.5" MAX CONCRETE LANDING SA SA CO A-7 2 15"min 24 " m i n GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI WP/GFCI 7.75" MAX S D D S 3 D3D S D F F S S D S N1 N2 EGRESS N3 N4 N6 N9 N10 N8 N11 - --- A-A A-7 INDOOR AIR QUALITY (IAQ) FAN-45 CFM MIN 3' - 0 " 3'-0" MIN 4' - 0" 3' OVERHANG 5' - 0" PORCH (N)5/8" GYPSUM BOARD TYPE "X" A-7 4,5 A-7 4 36" MIN TE M P E R E D ELECTRIC RANGE: NO GAS HOOK UP AT STOVE. VS A-7 7 A-7 7 N7 Scale Project number Date Drawn by Owner Project Address Phone 1/4" = 1'-0" A-5 FLOOR PLAN 37-23 NANCY CALTAGIRONE 08/2024 JENNY PARADA Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 613 S EASTBURY AVE, COVINA CA 91723 DOOR SCHEDULE # HEIGHT THICKNESSWIDTH SIZE NOTES QUANTITY WINDOW SCHEDULE WIDTH#TYPEHEIGHT NOTES 4'-0" 5'-0" A B 4'-0" 4'-0" SLIDING 5'-0" 1 3/8" 1 3/8"3'-0"6'-8"1 2 3 ENTRY DOOR DOUBLE FRENCH DOOR - TEMPERED DOUBLE GLAZING DOUBLE GLAZING-EGRESS 1 1 1 3/8" C N1 N2 N3 N4 SLEEPING ROOMS MUST HAVE A WINDOW OR EXTERIOR DOOR FOR AN EMERGENCY EXIT, SILL HEIGHT NOT MORE THAN 44 INCHES ABOVE THE FLOOR, 5.7 SQ. FT. OF OPENABLE AREA, 24 INCHES CLEAR OPENING HEIGHT, 20 INCHES CLEAR OPENING WIDTH AND SHALL OPEN DIRECTLY INTO A PUBLIC STREET, ALLEY, YARD, OR EXIT COURT. PROVIDE 15" MINIMUM BETWEEN THE CENTER OF WATER CLOSET TO ANY SIDE WALL. PROVIDE 24" CLEAR SPACE IN FRONT OF ANY WATER CLOSET. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH MECHANICAL VENTILATION CAPABLE OF 50 CFM MIN EXHAUSTED DIRECTLY TO THE OUTSIDE WITH HUMIDITY CONTROL. KEY NOTES S DIMMER (PROVIDE VACANCY SENSOR AT BATHROOMS) GFIT PROVIDE EXHAUST FAN OF 4 AIR CHANGES PER HOUR MINIMUM, WITH HUMIDITY CONTROL SENSOR. 50 CFM MIN "FANS SHALL BE ENERGY STAR COMPLIANT CONTROLLED BY HUMIDISTAT AND DUCTED TO TERMINATE TO THE OUTSIDE OF THE BUILDING" LEGEND SMOKE ALARM TO BE HARD WIRED WITH BATTERY BACK UP AND INTERCONNECTED TO SOUND AT THE SAME TIME COMBO SMOKE AND CARBON MONOXIDE ALARM TO BE HARD WIRED WITH BATTERY BACK UP AND INTERCONNECTED TO SOUND AT THE SAME TIME SA SA CO GAS SWITCH LIGHT FIXTURE WITH PHOTOCONTROL & MOTION SENSOR MS EFF LIGHT HIGH EFFICACY D NEW WOOD STUD FRAMING 2X4 OR 2X6 AT 16"O.C. NEW 1-HR FIRE RATED WALL OUTLET GROUND FAULT INTERRUPTER TAMPER PROOF, WATER RESISTANT WITH BUBLE COVER OUTLET AFCI N5 ATTIC ACCESS WITH A MINIMUM SIZE OF 22 X 30 INCHES UNLESS THE MAXIMUM VERTICAL HEADROOM HEIGHT IN THE ATTIC IS LESS THAN 30 INCHES. WHERE MECHANICAL EQUIPMENT IS INSTALLED IN THE ATTIC THE MINIMUM DIMENSIONS ARE 30 INCHES X 30 INCHES AND AT LEAST AS LARGE AS THE LARGEST COMPONENT OF THE APPLIANCE. U-FACTOR 2'-0" 2'-0"SLIDING 2 INTERIOR COLONISH,PRE-HUNG DOOR2'-8"6'-8" PROPOSED FLOOR PLAN ESC 1/4"=1'-0" 4 PATIO DOOR 1 3/8" OBSCURE TEMPERED GLASS N6 SHOWERS AND SHOWER-TUBS SHALL BE PROVIDED WITH INDIVIDUAL CONTROL VALVES OF THE PRESSURE BALANCE, THERMOSTATIC, OR COMBINATION PRESSURE BALANCE/THEROSTATIC MIXING VALVE TYPE THAT PROVIDE SCALD AND THERMAL SHOCK PROTECTION. PROVIDE SMOKE ALARMS IN EACH NEW AND EXISTING SLEEPING ROOM AND AT A POINT ON THE CEILING OR WALL OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF BEDROOMS. IN NEW CONSTRUCTION, THE REQUIRED SMOKE ALARMS SHALL RCEIVE THEIR PRIMARY POWER FROM THE BUILDING WIRING AND SHALL BE EQUIPPEED WITH A BATTERY BACKUP. SMOKE ALARMS MAY BE SOLELY BATTERY OPERATED WHEN INSTALLED IN EXISTITNG SLEEPING ROOMS AND HALLWAYS. N7 NEEA HEAT PUMP WATER HEATER 50 GAL MIN N8 CLOTHER DRYER MOISTURE EXHAUST DUCTS SHALL TERMINATE OUTSIDE OF THE BUILDING AND HAVE A BACK-DRAFT DAMPER. EXHAUST DUCT IS LIMITED TO 14 FEET WITH 2 ELBOWS. THIS SHALL BE REDUCED 2 FEET FOR EVERY ELBOW IN EXCESS OF 2. MINIMUM 4 INCH DIAMETER, SMOOTH, METAL DUCT. SEE DETAIL 6, SHEET A-7 N9 SAFETY GLAZING SHALL BE PROVIDED IN SHOWER AND TUB ENCLOSURES (LESS THAN 60" ABOVE STANDING SURFACE & 60" HORIZONTALLY FROM EDGE OF BATHTUB AND SHOWER) N10 SHOWERS AND WALLS ABOVE BATHTUBS WITH SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCH ABOVE THE DRAIN INLET. 6'-0" MIRROR WARDROBE DOOR6'-8" 6'-8" 6'-8"5 2'-0"1 3/8" BI-FOLD DOOR6'-8"6 6'-0"1 3/8" 3'-0"D 3'-0"DOUBLE GLAZING1 SLIDING SLIDING ADU PROVIDE 100 CFM NON-RECIRCULING EXHAUST FAN N11 No. Description Date 1 Revision 1 Date 1 714-997-0313 1) At least one bathroom on the entry level shall be provided with reinforcement for grab bars, where there is no bathroom on the entry level, at least one bathroom on the second or third floor of the dwelling shall comply with CRC R327.1.1. (SEE DETAIL AND NOTES ON THIS SHEET) 2) Electrical receptacle outlets, switches and controls shall be located no more than 48” measured from the top of the outlet box and not less than 15” measured from the bottom of the outlet box above the finish floor. CRC R327.1.2. 3) Doorbell buttons shall not be installed more than 48” above exterior floor or landing. CRC R327.1.4. AGING -IN-PLACE AND FALL PREVENTION NOTES (CRC R327): GRAB BARS DETAILS At least one bathroom on the entry level shall be provided with reinforcement installed in accordance with this section. (CRC R327.1.1) a. Reinforcement shall be solid lumber or other construction materials approved by the enforcing agency. b. Reinforcement shall not be less than 2 by 8 inch nominal lumber. (1-1/2 inch by 7-1/4 inch actual dimension) or other construction material providing equal height and load capacity. Reinforcement shall be located between 32 inches (812.8 mm) and 39-1/4 inches (997 mm) above the finished floor) flush with the wall framing. c. Water closet reinforcement shall be installed on both side walls of the fixture, or one side wall and the back wall. d. Shower reinforcement shall be continuous where wall framing is provided. e. Bathtub and combination bathtub/shower reinforcement shall be continuous on each end of the bathtub and the back wall. Additionally, back wall reinforcement for a lower grab bar shall be provided with the bottom edge located no more than 6 inches (152.4 mm) above the bathtub rim. SEE NOTE # 2 ON AGING-IN-PLACE NOTES SHGC 0.3 0.23 0.3 0.23 0.3 0.23 0.3 0.23 VS U-FACTOR SHGC 0.3 0.23 0.3 0.23 - - - - - - - - 1506 E Clemensen Ave & #212/12/2024 8' - 0 " 0' - 8 " M I N (N)A S P HALT SHIN G L E ROOF CL A SS "A" ESR-326 7(N)7 / 8 " STUC C O 12 ' - 9 " 8' - 0 " 0' - 8 " M I N 11 ' - 2 " (N)WEEP SCREED SEE DETAIL 7, SHEET A-7 (N)A S P HALT SHIN G L E ROOF CL A SS "A" ESR-326 7(N)7 / 8 " STUC C O 0' - 8 " M I N 8' - 0 " 12 ' - 0 " 0' - 8 " M I N 8' - 0 " 11 ' - 2 " 12 ' - 9 " (N)3 ' MIN OVER HANG OVER ENTRANCE 4' - 0 " (N)D O O R BELL BUTTON INST ALLE D M A X 4 ' ABOVE E X T ERIO R FLOOR (N)WEEP SCREED SEE DETAIL 7, SHEET A-7 (N)A S P HALT SHIN G L E ROOF CL A SS "A" ESR-326 7(N)7 / 8 " STUC C O 8' - 0 " 0' - 8 " M I N 12 ' - 0 " 8' - 0 " 0' - 8 " M I N 12 ' - 9 " 44 " M A X (N)WEEP SCREED SEE DETAIL 7, SHEET A-7 8' - 0 " 0' - 8 " M I N 12 ' - 0 " 8' - 0 " 0' - 8 " 11 ' - 2 " (N)A S P HALT SHIN G L E ROOF CL A SS "A" ESR-326 7(N)7 / 8 " STUC C O 12 ' - 9 " 3' - 0" (N)3 ' MIN OVER HANG OVER ENTRANCE (N)WEEP SCREED SEE DETAIL 7, SHEET A-7 Scale Project number Date Drawn by Owner Project Address Phone 1/4" = 1'-0" A-6 EXTERIOR ELEVATIONS 37-23 NANCY CALTAGIRONE 08/2024 JP Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 613 S EASTBURY AVE, COVINA CA 91723 ESC 1/4"=1'-0" ESC 1/4"=1'-0"ESC 1/4"=1'-0" SOUTH ELEVATION WEST ELEVATION NORTH ELEVATION ESC 1/4"=1'-0" EAST ELEVATION ADU No. Description Date 1 Revision 1 Date 1 714-997-0313 1506 E Clemensen Ave & #212/12/2024 N1 N1 N1 N1 N1 N1 (N ) 4 : 1 2 (N ) 4 : 1 2 (N)4:12 (N ) 4 : 1 2 (N)4:12 (N ) 4 : 1 2 (N)4:12 (N)4:12 1 (N)DORMER VENT DM-36 LEGEND ATTIC VENT CALCULATION TOTAL ATTIC AREA 1150 (SQ.FT.) SQ.FT. REQUIRED SQ.IN. REQUIRED 749 5.0 719.0 VENT TYPE NET FREE AREA SQ.IN QTY TOTAL SQ.IN. 1 DORMER 100 8 800 0 2 0 TOTAL 800 800 > 719.0 NOTE: 1. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1150 OR 1300 WHEN A MIN OF 3 FEET SEPARATION FROM EAVE VENTS TO GABLE/DORMER VENTS ARE SHOWN. CLASS I OR II VAPOR BARRIER IS INSTALLED ON THE WARM-IN-WINTER SIDE OF THE CEILING. NOTE: PROVIDE 8 DORMERS MANUFACTURER: LG OR SIMILAR MODEL: LG400N2W-V5 SOLAR PANEL SIZE: (L x W x H) 2,024mm x 1,024mm x 40mm 6.64' x 3.35' x 0.13' MAX POWER: 400 W REQ PV SYSTEM: 2,040 W 2,040 / 400= 5.1 = 6 SOLAR PANELS (N) PV SYSTEM REQUIRED 2.04 kWdc MIN SIZE 4:12 PITCH (N)ASPHALT SHINGLE ROOF CLASS "A" TIMBERLINE COOL SERIES-COOL BARKWOOD/BROWN COLOR ESR-3267 CRRC # 0676-0041a SOLAR REFLECTANCE 0.27 THERMAL EMITTANCE 0.90 SRI 28 (N)BEDROOM (N)GREAT ROOM 2 31 THRESHOLD SILL FLASHING, CONTINUE 2" UP EACH JAMB CONCRETE SLAB *TYPICAL TO SLABS AND DECKS BITUMINOUS PROTECTION BARRIER BETWEEN THRESHOLD AND UNITIZED FLASHING TO PREVENT GALVANIC REACTION DOOR FLASHING DETAILS @ DOORS PLYWOOD INSULATION # 2 - LAYERS TYPE "D" PAPER AND STUCCO WIRE STUCCO OVER 1/2" X 2" BACK DAM OR BEVELED WOOD SIDING SLOPED TO EXTERIOR PEEL-AND-STICK FLASHING DRYWALL WINDOW FLANGE WINDOW FLASHING DETAIL @ WINDOWSEMERGENCY EXIT SLEEPING ROOMS MUST HAVE A WINDOW OR EXTERIOR DOOR FOR AN EMERGENCY EXIT: - SILL HEIGHT NOT MORE THAN 44 INCHES ABOVE THE FLOOR - 5.0 SQ.FT. MIN CLEAR NET OPENABLE AREA OF GRADE FLOOR - 5.7 SQ. FT. MIN CLEAR NET OPENABLE AREA FROM THE FOURTH FLOOR TO THE SECOND FLOOR ABOVE GRADE - 24 INCHES MIN CLEAR OPENING HEIGHT - 20 INCHES MIN CLEAR OPENING WIDTH AND SHALL OPEN DIRECTLY INTO A PUBLIC STREET, ALLEY, YARD, OR EXIT COURT. F.F. 5.0 SQ.FT.MIN CLEAR OPENABLE AREA 5.0 SQ.FT.MIN CLEAR OPENABLE AREA MINIMUM SIZE WINDOW FOR 24" CLEAR WIDTH MINIMUM SIZE WINDOW FOR 20" CLEAR WIDTH 1-HR FIRE RATED WALL AND OVERHANG 4 1-HR FIRE RATED WALL ASSEMBLY 5 8" m i n PLYWOOD SHEARWALL PER STRUCTURAL 2 LAYERS BUILDING TYPE "D"PAPER 7 8"STUCCO PLASTER FINISH R-15 INSULATION 26 GAGI GALV. WEEP SCREED The weep screed at least 4-inches above exposed earth or 2-inches above hardscape. see notes 1'-3" MIN 24 " M I N 7SLAB ON GRADE FOOTING NOTES: - Requirements for a 19-mil (No. 26 galvanized sheet steel gage) or 50 mil PVC weep screed with a minimum 3-1/2 inch attachment flange that is capable of allowing trapped water to escape from behind the stucco. -The attachment flange at or below the sill/concrete interface. - The weep screed at least 4-inches above exposed earth or 2-inches above hardscape. 4 3 12"m i n VERTICAL DRYER VENT PRODUCT DATA product to vent or exhaust grease or liquid. Recommended use of this product is for exhaust of warm dry or slightly moist air only. Do not use thisNOTE: nailing flange. Apply moisture retardant over nailing flange in accordance with standard lathing practice. Affix dryer vent directly to structural members using galvanized fasteners one half inch in at each corner of the Waterproofing Manual. basis for detail whenever applicable as well as NRCA (National Roofing Contractors Association) Roofing and Conditioning Contractors National Association) Architectural Manual, current edition, shall be used as a guide and Installation shall be made in accordance with recognized sheet metal practices. SMACNA (Sheet Metal and Air uneven substrate. Before installing, ensure that the substrate is uniform and even. Do not install C & J Sheet Metal Products on TIONINSTALLA ASTM A653/A653M -G90 hot dipped galvanized steel, 26GA standard. TERIALSSTANDARD MA ATPRODUCT DA C & J METAL PRODUCTS INC 6925 DOWNEY AVENUE LONG BEACH CA 90805 VERTICAL DRYER VENT Designed for roof top venting where standard thru-wall discharge is not available. Built in concealed damper stays closed when not in use. NEW OR EXISTING ROOF (N)C.J. PER PLANS NEW OR EXISTING 2X STUDS 5 8" GYPSUM BOARD TYPE X (EACH SIDE) FROM FLOOR TO UNDERSIDE OF THE ROOF SHEATHING OR 1-HR RATED LATH AND PLASTER R-15 INSULATION R-30 INSULATION (N)PLYWOOD (WHERE OCCURS) 2X FIRE BLOCKING PERMITTED PROJECTIONS WITH A FIRE SEPARATION DISTANCE OF LESS THAN 5 FEET SHALL HAVE NOT LESS THAN ONE-HOUR FIRE-RESISTIVE CONSTRUCTION ON THE UNDERSIDE PL 24" MIN PER PLANS 12" A-7 ROOF PLAN & SECTION 37-23 08/2024 J.L.P. No. Description Date Scale Project number Date Drawn by SCALE 1/4"=1'-0" PROPOSED ROOF PLAN 613 S EASTBURY AVE, COVINA CA 91723 Owner Property Address Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 PHONE: NANCY CALTAGIRONE DRYER VENT 6 SCALE 1/4"=1'-0" SECTION A-A 714-997-0313 1506 E Clemensen Ave & #212/12/2024 DATE REVISIONS BY SEAL GE N E R A L N O T E S No 501 S. BRAND BLVD., SUITE 3 SAN FERNANDO, CA 91340 (323)486-4151 STENENGINEERING.COM SHEET: S1 DRAWN: CHECKED: DATE: SCALE: JOB #: B.O. E.N. N.T.S. EVGENY NA GOVITSY N 07/26/24 24-24-456 AD D R E S S : 1 5 0 6 C L E M E N S E N A V E , S A N T A A N A , C A 9 2 7 0 5 OW N E R : N A N C Y C A L T A G I R O N E NOTICE TO OWNER 1.THE ENGINEER DOES NOT WARRANT OR GUARANTEE THE ACCURACY AND COMPLETENESS OF THE WORK HEREIN BEYOND A REASONABLE DILIGENCE. IF ANY OMISSIONS, MISTAKES OR DISCREPANCIES ARE FOUND TO EXIST WITHIN THE WORK PRODUCT, THE ENGINEER SHALL BE PROMPTLY NOTIFIED SO THAT HE MAY HAVE THE OPPORTUNITY TO TAKE WHATEVER STEPS NECESSARY TO RESOLVE THEM. FAILURE TO PROMPTLY NOTIFY THE ENGINEER OF SUCH CONDITIONS SHALL ABSOLVE HIM FROM ANY RESPONSIBILITY FOR THE CONSEQUENCES OF SUCH FAILURE. 2.THE CONTRACTOR SHALL BE REQUIRED TO PERFORM AND INSTALL ANY AND ALL WORK, LABOR AND MATERIALS WHICH ARE NECESSARY. ALL CONTRACTORS SHALL BE LICENSED AND INSURED, OTHERWISE THE ENGINEER DOES NOT ASSUME ANY RESPONSIBILITY FOR HIS WORK. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND EXISTING CONDITIONS PRIOR TO STARTING ANY WORK. 3. ALL WORK SHALL CONFORM TO LOCAL AND NATIONAL CODES AND THE WORK HEREIN IS DEEMED TO BE AN ADDITION TO THE CALIFORNIA BUILDING CODE (CBC) NOTICE TO CONTRACTOR 1.ALL WORK SHALL COMPLY WITH THE CRC/CBC 2022 AND LATEST EDITION OF ALL LOCAL LAWS AND ORDINANCES, INCLUDING ENERGY CONSERVATION REQUIREMENTS BY THE STATE OF CALIFORNIA. 2.ALL WORK SHALL BE DONE IN AN APPROVED WORKMANLIKE MANNER. 3.CONTRACTOR SHALL VERIFY AND CHECK ALL DIMENSIONS AND ELEVATIONS AT THE PROJECT SITE AND THE OVERALL CORRECTNESS OF THESE DOCUMENTS BY STUDYING THEM THOROUGHLY AND IF THERE ARE ANY QUESTIONS TO CONTACT THE OWNER OR ENGINEER IMMEDIATELY FOR CLARIFICATION PRIOR TO THE BIDDING AND BEFORE THE START CONSTRUCTION. 4.DIMENSIONS HAVE PREFERENCE OVER SCALE. 5.APPROVALS BY BUILDING INSPECTOR SHALL NOT CONSTITUTE AUTHORITY TO DEVIATE FROM THESE PLANS AND SPECIFICATIONS. 6.ALL CONTRACTOR SHALL BE REQUIRED TO MAINTAIN WORKMAN'S COMPENSATION INSURANCE AS PROVIDED BY CALIFORNIA LAW, ALSO PUBLIC LIABILITY AND PROPERTY DAMAGE INSURANCE OF ADEQUATE COVERAGE, FIRE INSURANCE DURING CONSTRUCTION UP TO THE OCCUPANCY PERMIT, LIKEWISE FOR THEFT AND VANDALISM. 7.FOR GENERAL AND PLAN LAYOUT, CONSTRUCTION DETAILS, ETC. REFER ONLY TO THE ARCHITECTURAL SHEETS WHICH SHALL TAKE PRECEDENCE OVER ANY OTHER DRAWINGS. UNLESS OTHERWISE NOTED, ALL DIMENSIONS ARE SHOWN AS FOLLOWS: FACE OF WALL AT MASONRY, INDICATED FACE OF STUD, CENTER LINE,GRID LINE, TOP OF CONCRETE SLAB OR FOUNDATION, TOP OF PLYWOOD,ETC. DRAWINGS SHALL NOT BE SCALED TO DETERMINE ANY DIMENSIONS, REFER ONLY TO WRITTEN INFORMATION AND DETAIL DRAWINGS. GENERAL NOTES 1.ALL DETAILS, SECTIONS AND NOTES SHOWN ON THE DRAWING ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR SITUATIONS ELSEWHERE UNLESS OTHERWISE NOTED. NOTES AND DETAILS ON DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. 2.IN NO CASE SHALL WORKING DIMENSIONS BE SCALED FROM PLANS, SECTIONS OR DETAILS ON THE STRUCTURAL DRAWINGS. 3.SEE ARCHITECTURAL DRAWINGS FOR DOORS, WINDOWS, NON-BEARING INTERIOR AND EXTERIOR WALLS, ELEVATIONS, SLOPES, STAIRS, CURBS, DRAINS, DEPRESSIONS, RAILINGS, WATERPROOFING, FINISHING, ETC. 4.ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND/OR THE STRUCTURAL ENGINEER BEFORE PROCEEDING WITH ANY OF THE WORK INVOLVED. 5.ALL WORKMANSHIP AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE GOVERNING BUILDING CODE. 6.ALL ASST. DESIGNATIONS SHALL BE AS AMENDED TO DATE UNLESS OTHERWISE NOTED. 7.REFER TO THE SPECIFICATIONS FOR INFORMATION NOT COVERED BY THESE GENERAL MOTES OR THE STRUCTURAL ENGINEER WHERE APPLICABLE. 8.CONTINUOUS (OR SPECIAL) INSPECTION SHALL MEAN INSPECTION DONE CONTINUOUSLY BY A REGISTERED DEPUTY INSPECTOR CURRENTLY LICENSED BY THE CITY OR GOVERNING AGENCY. 9.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN AND AROUND THE JOB SITE AND/OR ADJACENT PROPERTIES. 10.SHOP DRAWINGS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT, ARCHITECT, AND STRUCTURAL ENGINEER PRIOR TO FABRICATION WITH SUFFICIENT TIME FOR REVIEW OF DESIGN INTENT (MIN. OF 10 WORKING DAYS). 11.DURING AND AFTER CONSTRUCTION, BUILDER AND/OR OWNER SHALL KEEP LOADS ON STRUCTURE WITHIN THE LIMITS OF DESIGN LOADS. 12.THE CONTRACTOR SHALL BE RESPONSIBLE FOR BRACING AND SHORING ALL EXCAVATIONS, TEMPORARY AND EXISTING STRUCTURES, AND PARTIALLY COMPLETED PORTIONS OF THE WORK TO ASSURE THE SAFETY OF ANY PERSON COMING IN CONTACT WITH THE WORK. 13.THE CONTRACTOR SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE PROPER ALIGNMENT OF THE STRUCTURE AFTER THE INSTALLATION OF ALL STRUCTURAL AND FINISH MATERIALS. 14.CONTRACTOR SHALL NOTIFY ADJACENT PROPERTY OWNERS, IN WRITING, OF HIS INTENSION THE START OF WORK SO THAT PROPERTY OWNERS MAY PROTECT THEIR PROPERTY. BASIS OF DESIGN 1.SOILS A. SOIL BEARING PRESSURE: 1500 PSF 2. LATERAL LOADS A. OCCUPANCY CATEGORY: II B. SEISMIC DESIGN CATEGORY: D C. SEISMIC IMPORTANCE FACTOR: 1.0 D. WIND DESIGN DATA: SPEED - 94 MPH, EXPOSURE - B E. SITE CLASS: D F. MAPPED SPECTRAL RESPONSE ACCELERATIONS SS AND S1: 1.332 AND 0.474 RESPECTIVELY G. SPECTRAL RESPONSE COEFFICIENTS SDS: 1.066 H. SEISMIC RESPONSE COEFFICIENT CS: 0.1640 I. DESIGN BASE SHEAR: 4.98 PSF J. REDUNDANCY FACTOR P: 1.3 K. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE L. BASIC SEISMIC FORCE RESISTING SYSTEM: PLYWOOD SHEAR WALLS M RESPONSE MODIFICATION FACTOR: 6.5 3.DESIGN LOADS A. ROOF LOAD: DL=15 PSF, LL=20 PSF B. CEILING LOAD: DL=5 PSF, LL=10 PSF C. FLOOR LOAD: DL=15 PSF, LL=40 PSF FOUNDATION 1.FOOTING EXCAVATION SHALL BE CLEAN AND FREE FROM LOOSE DEBRIS, STANDING WATER, OR UNCOMPACTED MATERIAL AT THE TIME OF CONCRETE PLACEMENT. 2.IF PROBLEMS ARE ENCOUNTERED IN THE FIELD AND NO SOIL REPORT EXIST, OWNER SHALL BE RESPONSIBLE FOR OBTAINING SOIL REPORT. 3.WATER PROOFING AS MAY BE REQUIRED AT SOIL FACE OF WALL BELOW GRADE SHALL BE BY OTHERS. 4.TRENCHES AND EXCAVATIONS UNDER OR ADJACENT TO FOUNDATIONS SHALL BE PROPERLY BACKFILLED AND COMPACTED. 5.PROVIDE A WEEP SCREED FOR STUCCO AT THE FOUNDATION PLATE LINE A MINIMUM 8" ABOVE THE EARTH OR 2" ABOVE PAVED AREAS. 6.ALL CONTINUOUS FOOTINGS TO HAVE 5/8"DIA. x MIN. 12" ANCHOR BOLTS, MIN. 7" EMBEDMENT INTO CONCRETE FOOTING AT 72" O.C. UNLESS NOTED OTHERWISE ON PLANS. ONE ANCHOR BOLT SHOULD BE LOCATED MAX. 12"AWAY AND MIN. 9 1/2" FROM THE END OF THE SILL PLATES. MIN. (2) A.B. PER SILL PLATE/SHEAR PANEL. SILL PLATE UNDER SHEAR WALLS OF UP TO 4'-0" IN LENGTH MUST BE CONTINUOUS. 7.ANCHOR BOLTS AT SHEAR WALLS SHALL BE INSTALLED WITH PLATE WASHERS OF MIN. 3" SQ. x 0.229" THICK BETWEEN SILL PLATE AND NUT. EDGE(S) OF PLATE WASHERS SHALL BE 1/2" MAX. FROM INSIDE FACE OF SHEAR PANEL(S). 8.FOUNDATION SILLS SHALL BE NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. 9.THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SLOTTED WITH A WIDTH OF UP TO 3/16 INCH LARGER THAN THE BOLT DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1 3/4 INCHES, PROVIDED A STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 10.FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 11.FOR INTERIOR NON-SHEAR WALLS USE SIMPSON PHNW SERIES 0. 145Ø PINS WITH A PENETRATION OF 1 1/4" INTO SLAB AT 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138. ACTUAL SLAB THICKNESS TO BE MINIMUM 4". ALL INTERIOR SHEAR WALLS TO HAVE A.B. PER FOUNDATION PLAN. 12.ALL HOLDOWNS AND POST ANCHORS TO BE INSTALLED ACCORDING TO MOST CURRENT SIMPSON STRONG TIE SPECIFICATIONS AND REQUIREMENTS OF ICC-ER REPORTS & SHALL BE TIED IN PLACE PRIOR TO FOUNDATION INSPECTION. DIMENSIONS ARE NOT FURNISHED TO SIMPSON HOLDOWNS. IT IS THE RESPONSIBILITY OF THE CONTRACTOR'S SUPERINTENDENT, THE FRAMING CONTRACTOR AND THE CONCRETE CONTRACTOR TO LOCATE THESE ANCHORS IN THE EXACT LOCATION. REFER TO DETAILS FOR PROPER INSTALLATION. 13.PLACEMENT SHALL BE IN ONE CONTINUOUS OPERATION UNLESS OTHERWISE SPECIFIED. SLAB SURFACE SHALL BE CURED WITH 'HUNTS' COMPOUND OR EQUAL OR CURED WITH OTHER METHODS IN ACCORDANCE WITH GOOD CONSTRUCTION PRACTICE AT CONTRACTOR'S OPTION. 14.CONTRACTOR SHALL DAMPEN SLAB UNDERLAYMENT OF SAND/MEMBRANE JUST PRIOR TO CONCRETE PLACEMENT TO ASSIST UNIFORM CONCRETE CURING. SLABS MUST NOT BE POURED DURING OR IMMEDIATELY AFTER RAINSTORMS. THE SPECIFIED SAND OVER VISQUEEN SHOULD NOT BE SATURATED AT THE TIME OF THE CONCRETE POUR.ANY FREE WATER TRAPPED IN THE SAND LAYER MUST BE REMOVED PRIOR TO THE CONCRETE POUR. 15.THE BOTTOMS OF FOOTING EXCAVATIONS SHALL BE LEVEL, CLEAN AND FREE OF LOOSE MATERIAL OR WATER WHEN CONCRETE IS PLACED. OVER EXCAVATION SHALL BE FILLED WITH CONCRETE OR PROPERLY COMPACTED FILL THAT HAS BEEN TESTED AND APPROVED BY THE SOILS ENGINEER. BACKFILL SHALL NOT BE PLACED UNTIL SUPPORTING FOUNDATIONS, WALLS AND SLAB HAVE ATTAINED SUFFICIENT STRENGTH TO SUPPORT LATERAL SOIL PRESSURE. 16.FLOOR SLAB SHALL BE POURED LEVEL TO 1/8" IN 10'. 17.FINISH GRADE AROUND THE PERIMETER OF SLAB SHALL BE CONSTRUCTED SUCH THAT RAIN AND IRRIGATION WATER IS DRAINED AWAY FROM THE SLAB. 18.FOUNDATION DRAWINGS PREPARED BY E.O.R. REFLECT THE STRUCTURAL REQUIREMENTS. REFER TO ARCHITECTURAL PLANS FOR DIMENSIONS, DEPRESSIONS, SLOPE, SHELVES, PATIOS, STOOPS AND PORCHES NOT SHOWN IN FOUNDATION DRAWINGS. ACCURACY OF THE DIMENSIONS AND FINAL FIT OF THE BUILDING SHALL BE REVIEWED BY THE ARCHITECT AND THE CONTRACTOR PRIOR TO CONSTRUCTION. 19.WAITING PERIOD FOR CONCRETE SLABS-ON-GRADE PRIOR TO START OF CONSTRUCTION IS AS FOLLOWS: a. DO NOT WALK ON SLAB UNTIL 24 HOURS AFTER CONCRETE HAS BEEN POURED. b. BEGIN WALL FRAMING 4-5 DAYS AFTER CONCRETE POURED. c. BEGIN ROOF/FLOOR FRAMING 7-10 DAYS AFTER CONCRETE POURED. d. DO NOT LOAD ROOF PRIOR TO 14 DAYS AFTER CONCRETE POURED. 20.NO PIPES OR CONDUITS SHALL EXTEND UNDER ISOLATED COLUMN FOOTING OR UNDER CONTINUOUS WALL FOOTINGS UNLESS SPECIFICALLY DETAILED OR APPROVED BY THE ARCHITECT, STRUCTURAL ENGINEER AND THE BUILDING OFFICIAL. 21.DEPUTY INSPECTION IS REQUIRED FOR SIMPSON SET-XP EPOXY. CONCRETE 1.CEMENT SHALL CONFORM TO A.S.T.M. C150, TYPE II. (U.N.O.) 2.HARD ROCK AGGREGATE SHALL CONFORM TO A.S.T.M. C33. THEIR MAX. SIZE SHALL BE 1 INCH FOR FOOTINGS, CAISSONS AND GRADE BEAMS AND I INCH FOR ALL OTHER WORK. PEA GRAVEL SHALL NOT BE USED WITHOUT WRITTEN PERMISSION OF ENGINEER. 3.LIGHTWEIGHT AGGREGATES (CONFORM TO A.S.T.M. C330) SHALL BE APPROVED AND THEIR MAX. SIZE SHALL BE 1/2 INCH. 4.CONCRETE COVER OVER REINFORCING SHALL BE AS FOLLOWS: (U.N.O.) 5.ALL REINFORCING SHOWN CONTINUOUS SHALL BE LAPPED PER DETAIL HEREON AT SPLICES AND SHALL BE MADE AWAY FROM POINTS OF MAXIMUM STRESS. MIN. LAP SHALL BE 24"LONG. 6.ALL REINFORCING STEEL, DOWELS AND ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN POSITION PRIOR TO POURING CONCRETE. 7.CONTINUOUS INSPECTION IS REQUIRED FOR ALL CONCRETE IN EXCESS OF 2,500 PSI.(U.N.O.) 8.BEFORE CONCRETE IS POURED, CHECK WITH ALL TRADES TO INSURE PROPER PLACEMENT OF ALL OPENINGS, SLEEVES, CURBS, CONDUITS, BOLTS, INSERTS, ETC. RELATING TO WORK. 9.ONLY ONE KIND OF CONCRETE SHALL BE POURED ON THE JOB AT ONE TIME. 10.ALL SLEEVES NOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL BE LOCATED BY THE TRADES INVOLVED AND SHALL BE APPROVED BY THE ENGINEER. 11. DRYPACK CONCRETE SHALL BE ONE PART PORTLAND CEMENT AND ONE PART SAND WITH SUFFICIENT WATER TO ALLOW A SMALL AMOUNT OF PASTE TO COME TO THE SURFACE. 12.CONCRETE GROUT SHALL BE NON-SHRINKING WITH SUFFICIENT WATER TO ALLOW POURING ULTIMATE COMPRESSIVE STRENGTH (F'c) AT 28 DAYS SHALL EQUAL 2,000 PSI. 13.MIX THAT PRODUCES LOWEST SLUMP COMPATIBLE WITH PROPER PLACEMENT SHALL BE USED. THE MAX. CONCRETE SLUMP SHALL BE 3 INCHES PLUS OR MINUS 1 INCH FOR SLABS ON GRADE AND 4 INCHES PLUS OR MINUS 1 INCH FOR ALL OTHER WORK. 14.LOCATION OF CONSTRUCTION OR POUR JOINTS MUST BE APPROVED BY THE STRUCTURAL ENGINEER IF OTHER THAN SHOWN ON THE PLANS. 15.NO PIPES OR DUCTS EXCEEDING ONE THIRD THE SLAB OR WALL - THICKNESS SHALL BE PLACED IN STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED. SEE THE MECHANICAL AND/OR ELECTRICAL DRAWINGS FOR LOCATION OF SLEEVES THROUGH WALLS AND FLOORS. 16.REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, ORNAMENTS, CLIPS, OR GROUND REQUIRED TO BE CAST IN CONCRETE, AND SLAB DEPRESSIONS. 17.REMOVAL OF FORMS: SUPPORTING VERTICAL SURFACES-MINIMUM 2 DAYS; SUPPORTING HORIZONTAL SURFACES-MINIMUM 14 DAYS (U.N.O.). 18. MAXIMUM WEIGHT OF LIGHTWEIGHT CONCRETE SHALL NOT EXCEED 110 PCF. CONDITION CONCRETE F'c @ 28 DAYS, PSI STEEL REINFORCEMENT Fy (YIELD), PSI CONTINUOUS INSPECTION REQUIRED CONTINUOUS FOOTING 2,500 40,000 NO ISOLATED PADS 2,500 40,000 NO GRADE BEAM 3,000 60,000 YES PILES 3,000 60,000 YES NOTE: A HIGHER GRADE OF CONCRETE MAY BE SUBSTITUTED FOR THOSE SHOWN ABOVE, BUT WILL BE SUBJECT TO THE CODE REQUIREMENTS OF HIGHER GRADE. POURED AGAINST EARTH - - - - - - - - - - - - - - - - -3 INCH CLEAR EXPOSED TO EARTH, BUT POURED AGAINST FORMS- - - - -2 INCH CLEAR MAIN BARS IN COLUMNS AND BEAMS - - - - - - - - - - -2 INCH CLEAR STRUCTURAL SLAB - - - - - - - - - - - - - - - - - - - 1 INCH CLEAR WALLS - - - - - - - - - - - - - - - - - - - - - - - - - 1 1/2 INCH CLEAR SLABS ON GRADE - - - - - - - - - - - - - - - - - - - - AT CENTER STRUCTURAL WOOD 1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR UNLESS NOTED OTHERWISE AND CONFORM TO GRADING RULES OF THE WESTERN WOOD PRODUCTS ASSOCIATION (U.N.O.). 2.ALL PLYWOOD SHALL CONFORM TO P,S.1-95 AND SHALL BE GRADED,INDEX NUMBER AND THICKNESS CALLED ON PLANS. ALL PLYWOOD DIRECTLY EXPOSED TO THE WEATHER SHALL BE EXTERIOR TYPE. 3.STRUCTURAL PLYWOOD SHALL BE GRADED PER A.P.A. AND SHALL BE INTERIOR TYPE SHEATHING C-D GRADE WITH EXTERIOR GLUE. ALL HORIZONTAL PLYWOOD SHALL BE LAID WITH FACE GRAIN PERPENDICULAR TO JOISTS AND WITH STAGGERED JOINTS. NO STRUCTURAL PLYWOOD SHALL BE COVERED OVER UNTIL AN INSPECTION HAS BEEN MADE AND NAILING APPROVED. 4.MINIMUM DIMENSIONS OF ANY PLYWOOD SHALL BE 18" AND A MINIMUM AREA 6 SF. 5.CUTTING AND BORING OF WOOD STUDS: EXTERIOR WALL AND BEARING WALL STUDS MAY BE NOTCHED TO MAX. OF 25% OF STUD DEPTH. NON-BEARING STUDS MAY BE NOTCHED TO MAX. 40% OF STUD DEPTH. A HOLE NOT GREATER THAN 40% OF THE STUD DEPTH MAY BE BORED IN ANY STUD AND 60% - IN NON-BEARING STUD. IN NO CASE SHALL THE EDGE OF BORED HOLE BE NEARER THAN 5/8"TO THE EDGE OF STUD. BORED HOLE SHALL NOT BE LOCATED AT THE SAME SECTION OF THE STUD AS CUT OR NOTCH. 6.ALL LUMBER IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURED TREATED PER IBC STD 7.WHERE PLUMBING, HEATING OR OTHER PIPES NECESSITATE THE CUTTING OF SOLES OR PLATES. THE CUT HOLES OR PLATES SHALL BE TIED BACK BY SIMPSON STRONG TIE ST22. 8.ALL NAILS SHALL BE COMMON AND NAILING SHALL CONFORM TO THE APPLICABLE BUILDING CODE 9.ALL STUD WALLS SHALL HAVE FIRE BLOCKING AT 8-0" O.C. MAX. 10.FASTENERS IN CONTACT WITH PRESERVATIVE TREATED LUMBER AND FIRE RETARDANT TREATED WOOD SHALL BE OF HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER 11.TOP PLATES OF ALL WOOD STUD WALLS TO CONSIST OF (2) 2x THE SAME WIDTH AS THE STUD U.N.O. TOP PLATE SHALL LAP A MIN. 48" AND BE SPLICED WITH NOT LESS THEN (6) 16d NAILS SPACED NOT MORE THAN 12" O.C. 12.PROVIDE POST/ MULTIPLE STUDS AT LOWER FLOOR UNDER POST/ MULTIPLE STUDS ABOVE 13.ALL JOIST HANGERS SHALL BE SIMPSON LUS-TYPE HANGER, ALL BEAM HANGERS SHALL BE SIMPSON HUS-TYPE HANGER U.N.O. ON PLAN OR DETAIL. FOLLOW MANUFACTURER RECOMMENDATION FOR INSTALLATION. 14.USE THIS SPAN TABLE FOR STUD SPACING, U.N.O.: 15.USE THIS SPAN TABLE FOR ROOF RAFTERS, U.N.O.: 16.USE THIS SPAN TABLE FOR CEILING JOISTS, U.N.O.: 17.USE THIS TABLE FOR FLOOR JOISTS, U.N.O.: 2x ROOF RAFTERS - - - - - - - - - - - - - - - - - - - - GRADE #2 2x FLOOR JOISTS - - - - - - - - - - - - - - - - - - - - GRADE #2 4x BEAMS, POSTS AND HEADERS - - - - - - - - - - - - -GRADE #1 6x BEAMS, LEDGERS AND POSTS - - - - - - - - - - - - -GRADE #1 STUDS AND PLATES STANDARD GRADING MIN. BEARING TO 8 FT. - - - - - - - - - - - - - - - - - - -2x4 GRADE STUD FROM 8 FT. TO 14 FT. - - - - - - - - - - - - - - - - -2x6 GRADE #1 FROM 14 FT. TO 20 FT. - - - - - - - - - - - - - - - - 2x8 GRADE #1 NON-BEARING TO 10 FT. - - - - - - - - - - - - - - - -2x4 GRADE STUD FROM 10 FT. TO 20 FT. - - - - - - - - - - - - - - - - SAME AS BEARING SILL PLATES (P.T.D.F.) - - - - - - - - - - - - - - - - - - GRADE STUD OR CONST BLOCKING, TOP AND BOTTOM PLATES - - - - - - - - - - -GRADE STUD OR CONST SIZE, HEIGHT AND SPACING OF WOOD STUDS, CRC TABLE R602.3(5) BEARING WALLS NON-BEARING WALLS STUD SIZE STUD HEIGHT MAXIMUM SPACING WHEN SUPPORTING STUD HEIGHT MAXIMUM SPACINGROOF & CLN'G ONLY ONE FLOOR, ROOF & CLN'G TWO FLOORS, ROOF & CLN'G ONE FLOOR ONLY 2x4 10 24" 16" --- 24" 14' 24" 3x4 10 24" 24" 16" 24" 14' 24" 2x6 10 24" 24" 16" 24" 20' 24" *NO MULTIPLES OF 2x4 ARE ALLOWED TO SPAN MORE THAN 14'. BEARING WALLS EXCEEDING 10' MUST BE DESIGNED CASE BY CASE RAFTER SPANS, CRC TABLE R802.4.1.(2) SIZE SPACING ALLOWABLE SPAN SIZE SPACING ALLOWABLE SPAN A. DEAD LOAD=20 PSF B. LIVE LOAD=20 PSF C. TOTAL DEFLECTION=L/240 D. USE DOUGLAS FIR LARCH #2 2x6 24"10'-4" 2x10 24" 15'-11" 16" 12'-7"16" 19'-6" 12" 14'-7"12" 22'-6" 2x8 24" 13'-0" 2x12 24" 18'-6" 16" 16'-0"16" 22'-7" 12" 18'-5"12" 26'-0" CEILING JOIST SPANS, CRC TABLE R802.5.1.(1) SIZE SPACING ALLOWABLE SPAN SIZE SPACING ALLOWABLE SPAN A. DEAD LOAD=5 PSF B. LIVE LOAD=10 PSF C. TOTAL DEFLECTION=L/240 D. USE DOUGLAS FIR LARCH #2 2x6 24"15'-0" 2x10 24" 23'-3" 16" 17'-8"16" EXCEEDS 26' 12" 19'-6"12" EXCEEDS 26' 2x8 24" 19'-1" 2x12 24" EXCEEDS 26' 16" 23'-4"16" EXCEEDS 26' 12" 25'-8"12" EXCEEDS 26' FLOOR JOIST SPANS, CRC TABLE R502.3.1.(2) SIZE SPACING ALLOWABLE SPAN SIZE SPACING ALLOWABLE SPAN A. DEAD LOAD=20 PSF B. LIVE LOAD=40 PSF C. TOTAL DEFLECTION=L/360 D. USE DOUGLAS FIR LARCH #2 2x6 24"7'-6" 2x10 24" 11'-8" 16" 9'-3"16" 14'-3" 12" 10'-8"12" 16'-5" 2x8 24" 9'6" 2x12 24" 13'-6" 16" 11'-8"16" 16'-6" 12" 13'-6"12" 19'-1" SHEAR WALL 1.ALL GYPSUM WALL BOARD AND STUCCO SHEAR WALLS SHALL HAVE NAILING PROVIDED AT TOP AND BOTTOM PLATES, ALL STUDS AND BLOCKING. 2.BLOCK ALL EDGES OF WOOD SHEATHED SHEAR WALLS. 3.SHEAR WALL PLATES AND STUDS SHALL NOT HAVE HOLES LARGER THAN 1" DIAMETER WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. SHEAR WALL PLATES AND STUDS SHALL NOT HAVE ANY NOTCHES WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. 4.PROVIDE MULTIPLE STUDS FOR SOLID BEARING AT ENDS OF MISCELLANEOUS BEAMS WHERE POSTS ARE NOT SHOWN. CARRY STUDS DOWN TO FOUNDATION OR SLAB. 5.MIN. SPLICE NAILING OF DOUBLE PLATES SHALL BE (12) 16d NAILS U.N.O 6.AT PLYWOOD SHEAR WALLS, PLYWOOD TO EXTEND ABOVE AND BELOW AND SIDES OF ALL OPENINGS. 7.PLYWOOD AT SHEAR WALLS TO BE CONTINUOUS AT WALL AND DOOR JAMB INTERSECTION. 8.MINIMUM DIMENSIONS OF ANY PLYWOOD SHALL BE 18" AND A MINIMUM AREA 6 SF. 9.SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. 10.NAILING AT 6" O.C. WHEN STUDS ARE SPACES AT 24" O.C. 11. SPACING OF A35/ LTP4, 16d NAILS, SDS SCREWS, AND ANCHOR BOLTS IS TO BE REDUCED BY 1/2, IF PLYWOOD SHEATHING OCCURS ON BOTH SIDES OF WALL. 12.NAIL SPACING W/ LESS THAN 4" O.C. SHALL HOVE A PRE-DRILLED HOLE, WHEN USED, WHICH CAN NOT EXCEED 75% OF THE NAIL DIAMETER (BUT SHOULD BE AS CLOSE TO 75% AS POSSIBLE). UNSEASONED LUMBER IS ASSUMED TO BE USED. 13.ONLY COMMON NAILS WILL BE USED FOR ALL PLYWOOD SHEAR WALLS AND NAIL GUNS USING "CLIPPED HEAD” OR "SINKER" NAILS ARE NOT ACCEPTABLE. 14.ALL BOLT HOLES TO BE DRILLED 1/32" MIN. TO 1/16" MAX. OVERSIZED. INSPECTOR MUST VERIFY. 15.ALL SHEAR WALLS WITH A SHEAR VALUE GREATER THAN 300 LB/FT SHOULD BE PROVIDED: a) 3x FOUNDATION SILL PLATES b) 3x STUDS AND BLOCKS BETWEEN ADJACENT PANELS c) 1/2" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING d) ALL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED. e) STAGGER NAILS IF NAIL SPACING IS LESS THAN 2" O.C. f) SQUARE PLATE WASHERS SHALL BE USED WITH ANCHOR BOLTS 5/8" ∅ BOLT - 3"x3"x1/4" 3/4" ∅ BOLT - 3"x3"x5/16" 7/8" ∅ BOLT - 3"x3"x5/16" 1" ∅ BOLT - 3.5"x3.5"x3/8" SHEAR WALL SCHEDULE TYPE SHEATHING MATERIAL PANEL NAILING PERIMETER FIELD BLKG. TO PLATE CONNECTION PLATE TO BLKG. CONNECTION ANCHOR BOLTS (U.N.O.) EMBED. DEPTH SHEAR, PLF (LRFD) SHEAR, PLF (ASD) SILL PLATE 1 15/32" PLYWOOD STRUCTURAL 1 10d @ 6" O.C. 10d @ 12" O.C. A35/ LTP4 @ 20" O.C. 20d NAILS @ 6" O.C. 5/8"∅ @ 48" O.C.9" 392 245 2x 2 15/32" PLYWOOD STRUCTURAL 1 10d @ 6" O.C. 10d @ 12" O.C. A35/ LTP4 @ 16" O.C. 20d NAILS @ 4" O.C. 5/8"∅ @ 32" O.C.9" 544 340 3x 3 15/32" PLYWOOD STRUCTURAL 1 10d @ 4" O.C. 10d @ 12" O.C. A35/ LTP4 @ 10" O.C. SDS 1/4"x6" @ 8" O.C. 5/8"∅ @24" O.C.9" 816 510 3x 4 15/32" PLYWOOD STRUCTURAL 1 10d @ 3" O.C. 10d @ 12" O.C. A35/ LTP4 @ 8" O.C. SDS 1/4"x6" @ 5" O.C. 5/8"∅ @ 24" O.C.9" 1064 665 3x 5 15/32" PLYWOOD STRUCTURAL 1 10d @ 2" O.C. 10d @ 12" O.C. A35/ LTP4 @ 6" O.C. SDS 1/4"x6" @ 4" O.C. 5/8"∅ @ 16" O.C.9" 1392 870 3x GENERAL NOTES FOR STRUCTURAL OBSERVATION 1. (1) STRUCTURAL OBSERVATION IS REQUIRED FOR THE STRUCTURAL SYSTEM IN ACCORDANCE WITH THE INFORMATION BULLETIN NO. P/BC 2017-024. STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION AT THE CONSTRUCTION SITE OF THE ELEMENTS AND CONNECTIONS OF THE STRUCTURAL SYSTEM AT SIGNIFICANT CONSTRUCTION STAGES, AND THE COMPLETE STRUCTURE FOR GENERAL CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS. STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR THE INSPECTIONS REQUIRED OF THE BUILDING INSPECTOR OR THE DEPUTY INSPECTOR. 2. THE OWNER SHALL EMPLOY A STATE OF CALIFORNIA REGISTERED CIVIL OR STRUCTURAL ENGINEER OR LICENSED ARCHITECT TO PERFORM THE STRUCTURAL OBSERVATION. THE LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY (LADBS) REQUIRES THE USE OF THE ENGINEER OR ARCHITECT, OR HIS/HER DESIGNEE RESPONSIBLE FOR THE STRUCTURAL DESIGN WHO ARE INDEPENDENT OF THE CONTRACTOR. 3. THE STRUCTURAL OBSERVER SHALL PROVIDE EVIDENCE OF EMPLOYMENT BY THE OWNER OR THE OWNER’S REPRESENTATIVE. A LETTER FROM THE OWNER, THE OWNER’S REPRESENTATIVE, OR A COPY OF THE AGREEMENT FOR SERVICES SHALL BE SENT TO THE BUILDING INSPECTOR BEFORE THE FIRST SITE VISIT. 4. THE OWNER OR OWNER'S REPRESENTATIVE SHALL COORDINATE AND CALL FOR A MEETING BETWEEN THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, STRUCTURAL OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND DEPUTY INSPECTORS. THE PURPOSE OF THE MEETING SHALL BE TO IDENTIFY THE MAJOR STRUCTURAL ELEMENTS AND CONNECTIONS THAT AFFECT THE VERTICAL AND LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW SCHEDULING OF THE REQUIRED OBSERVATIONS. A RECORD OF THE MEETING SHALL BE INCLUDED IN THE FIRST OBSERVATION REPORT SUBMITTED TO THE BUILDING INSPECTOR. 5. THE STRUCTURAL OBSERVER SHALL PERFORM SITE VISITS AT THOSE STEPS IN THE PROGRESS OF THE WORK THAT ALLOW FOR CORRECTION OF DEFICIENCIES WITHOUT SUBSTANTIAL EFFORT OR UNCOVERING OF THE WORK INVOLVED. AT A MINIMUM, THE LISTED SIGNIFICANT CONSTRUCTION STAGES ON EITHER THE “STRUCTURAL OBSERVATION/SIGNIFICANT CONSTRUCTION STAGES” FORM OR THE “STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER” FORM IN/FORM.08 (PART 2) REQUIRE A SITE VISIT AND AN OBSERVATION REPORT FROM THE STRUCTURAL OBSERVER. 6. THE STRUCTURAL OBSERVER SHALL PREPARE A REPORT OF THE “STRUCTURAL OBSERVATION REPORT FORM” IN/FORM.08 (PART 1) FOR EACH SIGNIFICANT STAGE OF CONSTRUCTION OBSERVED. THE ORIGINAL OF THE STRUCTURAL OBSERVATION REPORT SHALL BE SENT TO THE BUILDING INSPECTOR'S OFFICE AND SHALL BE SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL OBSERVER. ONE COPY OF THE OBSERVATION REPORT SHALL BE ATTACHED TO THE APPROVED PLANS. THE COPY ATTACHED TO THE PLANS SHALL BE SIGNED AND SEALED (WET STAMP) BY THE RESPONSIBLE STRUCTURAL OBSERVER OR THEIR DESIGNEE. COPIES OF THE REPORT SHALL ALSO BE GIVEN TO THE OWNER, CONTRACTOR, AND DEPUTY INSPECTOR. ANY DEFICIENCY NOTED ON THE OBSERVATION REPORT WILL BECOME THE RESPONSIBILITY OF THE STRUCTURAL ENGINEER OR ARCHITECT OF RECORD TO VERIFY ITS COMPLETION BY THE STRUCTURAL OBSERVER. 7. A FINAL OBSERVATION REPORT MUST BE SUBMITTED WHICH SHOWS THAT ALL OBSERVED DEFICIENCIES WERE RESOLVED AND STRUCTURAL SYSTEM GENERALLY CONFORMS WITH THE APPROVED PLANS AND SPECIFICATIONS. THE LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY (LADBS) WILL NOT ACCEPT THE STRUCTURAL WORK WITHOUT THE FINAL OBSERVATION REPORT AND THE CORRECTION OF SPECIFIC DEFICIENCIES NOTED DURING NORMAL BUILDING INSPECTION. 8. THE STRUCTURAL OBSERVER SHALL PROVIDE THE ORIGINAL STAMPED AND SIGNED “STRUCTURAL OBSERVATION REPORT FORM” TO THE CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY BUILDING INSPECTOR. 9. WHEN THERE IS A NEED TO REPLACE THE STRUCTURAL OBSERVER OF RECORD, THE OWNER SHALL: A) NOTIFY THE BUILDING INSPECTOR IN WRITING BEFORE THE NEXT INSPECTION BY SUBMITTING COMPLETED “STRUCTURAL OBSERVATION PROGRAM AND DESIGNATION OF THE STRUCTURAL OBSERVER” FORM IN/FORM.08 (PART 2). B) CALL AN ADDITIONAL PRECONSTRUCTION MEETING, AND C) FURNISH THE REPLACEMENT STRUCTURAL OBSERVER WITH A COPY OF ALL PREVIOUS OBSERVATION REPORTS. D) THE NEW STRUCTURAL OBSERVER MUST BE DESIGNATED BY THE ENGINEER OR ARCHITECT OF RECORD. THE REPLACEMENT STRUCTURAL OBSERVER SHALL APPROVE THE CORRECTION OF THE ORIGINAL OBSERVED DEFICIENCIES UNLESS OTHERWISE APPROVED BY PLAN CHECK SUPERVISION. THE POLICY OF THE DEPARTMENT SHALL BE TO CORRECT ANY PROPERLY NOTED DEFICIENCIES WITHOUT CONSIDERATION OF THEIR SOURCE. 10.THE ENGINEER OR ARCHITECT OF RECORD SHALL DEVELOP ALL CHANGES RELATING TO THE STRUCTURAL SYSTEMS. THE 11. BUILDING DEPARTMENT SHALL REVIEW AND APPROVE ALL CHANGES TO THE APPROVED PLANS AND SPECIFICATIONS. NAILING SCHEDULE CONNECTION NAILINGa 1. JOIST TO SILL OR GIRDER, TOE NAIL 3-8d 2. BRIDGING TO JOIST, TOE NAIL EACH END 2-8d 3. 1" x 6”(25 mm x 125 mm) SUBFLOOR TO EACH JOIST, FACE NAIL 2-8d 4. WIDER THAN 1" x 6" (25 mm x 152 mm) SUBFLOOR TO EACH JOIST, FACE NAIL 3-8d 5. 2" (51 mm) SUBFLOOR TO JOIST OR GIRDER, BLIND AND FACE NAIL 2-16d 6. SOLE PLATE TO JOIST OR BLOCKING, TYPICAL FACE NAIL 16d AT 16" (406 mm) O.C. SOLE PLATE TO JOIST OR BLOCKING. AT BRACED WALL PANELS 3-16d PER 16" (406 mm) 7. TOP PLATE TO STUD, END NAIL 2-16d 8. STUD TO SOLE PLATE 4-8d, TOENAIL OR 2-16d, END NAIL 9. DOUBLE STUDS, FACE NAIL 16d AT 24" (610 mm) O.C. 10. DOUBLE TOP PLATES, TYPICAL FACE NAIL 15d AT 16" (405 mm) O.C. DOUBLE TOP PLATES, LAP SPLICE 8-16d 11. BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOE NAIL 3-8d 12. RIM JOIST TO TOP PLATE, TOE NAIL 8d AT 6 " (152 mm) O.C. 13. TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL 2-16d 14. CONTINUOUS HEADER, TWO PIECES 16d AT 16" (406 mm) O.C. ALONG EACH EDGE 15. CEILING JOIST TO PLATE, TOE NAIL 3-8d 16. CONTINUOUS HEADER TO STUD, TOE NAIL 4-8d 17. CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL 3-16d 18. CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL 3-16d 19. RAFTER TO PLATE, TOE NAIL 3-8d 20. 1" (25 mm) BRACE TO EACH STUD AND PLATE, FACE NAIL 2-8d 21. 1" x 8" (25 mm x 203 mm) SHEATHING OR LESS TO EACH BEARING, FACE NAIL 3-8d 22. WIDER THAN 1" x 8" (25 mm x 203 mm) SHEATHING TO EACH BEARING. FACE NAIL 3-8d 23. BUILT-UP CORNER STUDS 16d AT 24" (610 mm) O.C. 24. BUILT-UP GIRDER AND BEAMS 20d AT 32" (813 mm) O.C. AT TOP AND BOTTOM AND STAGGERED 2-20d AT ENDS AND AT EACH SPLICE 25. 2" (51 mm) PLANKS 2-16d AT EACH BEARING 26. COLLAR TIE TO RAFTER, FACE NAIL 3-10d 27. ROOF RAFTER TO HIP. TOE NAIL 3-10d 28. ROOF RAFTER TO 2x RIDGE BEAM, TOE NAIL, FACE NAIL 2-16d 29. JOIST TO BAND JOIST, FACE NAIL 3-16d 30. LEDGER STRIP, FACE NAIL 3-16d 31. WOOD STRUCTURAL PANELS AND PARTICLE BOARDb. SUBFLOOR, ROOF AND WALL SHEATHING (TO FRAMING): 1/2" (12.7 mm) AND LESS 6dc,l 19/32" - 3/4" (15 mm -19 mm) 8dd OR 6de 7/8" - 1" (22 mm - 25 mm) 8dc 1 1/8" - 1 1/4" (29 mm -32 mm) 10dd OR 8dd COMBINATION SUBFLOOR-UNDERLAYMENT (TO FRAMING): 3/4" (19 mm) AND LESS 6de 7/8" - 1" (22 mm -25 mm) 8de 1 1/8" - 1 1/4" (29 mm -32 mm) 10dd OR 8de 32. PANEL SIDING (TO FRAMING): 1/2" (12.7 mm) OR LESS 6df 5/8" (16mm) 8df 33. FIBERBOARD SHEATHINGg: 1/2" (12.7 mm) NO. 11 GAh 6 d NO. 16 GAi 25/32”(20 mm) NO. 11 GAh 8d NO. 16 GAi 34. INTERIOR PANELING: 1/4”(6.4 mm) 4d j 3/8" (9.5 mm) 6dk a COMMON OR BOX NAILS MAY BE USED EXCEPT WHERE OTHERWISE STATED. b NAILS SPACED AT 6 INCHES (152 mm) ON CENTER AT EDGES, 12 INCHES (305 mm) AT INTERMEDIATE SUPPORTS EXCEPT 6 INCHES (152 mm )AT ALL SUPPORTS WHERE SPANS ARE 48 INCHES (1219 mm) OR MORE. FOR NAILING OF WOOD STRUCTURAL PANEL AND PARTICLEBOARD DIAPHRAGMS AND SHEAR WALLS, REFER TO SECTION 23 NAILS FOR WALL SHEATHING MAY BE COMMON, BOX OR CASING. c COMMON OR DEFORMED SHANK. d COMMON. e DEFORMED SHANK. f CORROSION-RESISTANT SIDING OR CASING NAILS g FASTENERS SPACED 3 INCHES (76 mm) ON CENTER AT EXTERIOR EDGES AND 6 INCHES (152 mm) ON CENTER AT INTERMEDIATE SUPPORTS. h CORROSION-RESISTANT ROOFING NAILS WITH 7/16 INCH (11 mm) HEAD AND 1 1/2 INCH (38 mm) LENGTH FOR 1/2 INCH (12.7 mm) SHEATHING AND 1 3/4 INCH (44 mm) LENGTH FOR 25/32 INCH (20 mm) SHEATHING. i CORROSION - RESISTANT STAPLES WITH NOMINAL 7/16 INCH (11 mm) CROWN AND 1 1/8 INCH (29 mm) LENGTH FOR 1/2 INCH (12.7 mm) SHEATHING AND 1 1/2 INCH (38 mm) LENGTH FOR 25/32 INCH (20 mm) SHEATHING PANEL SUPPORTS AT 16 INCHES (406 mm) [20 INCHES (508 mm) IF STRENGTH AXIS IN THE LONG DIRECTION OF THE PANEL, UNLESS OTHERWISE MARKED]. j CASING OR FINISH NAILS SPACED 6 INCHES (152 mm) ON PANEL EDGES, 12 INCHES (305 mm) AT INTERMEDIATE SUPPORTS. k PANEL SUPPORTS AT 24 INCHES (610 mm). CASING OR FINISH NAILS SPACED 6 INCHES (152 mm) ON PANEL EDGES 12 INCHES (305 mm) AT INTERMEDIATE SUPPORTS. l FOR ROOF SHEATHING APPLICATIONS, 8d NAILS ARE THE MINIMUM REQUIRED FOR WOOD STRUCTURAL PANELS. m STAPLES SHALL HAVE A MINIMUM CROWN WIDTH OF 7/16 INCH. n FOR ROOF SHEATHING APPLICATIONS, FASTENERS SPACED 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS. o FASTENERS SPACED 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS FOR SUBFLOOR AND WALL SHEATHING AND 3 INCHES ON CENTER EDGES, 6 INCHES AT INTERMEDIATE SUPPORTS FOR ROOF SHEATHING. p FASTENERS SPACED 4 INCHES ON CENTER AT EDGES, 8 INCHES AT INTERMEDIATE SUPPORTS. IF LOCAL BUILDING AND SAFETY CODE DIFFERS FROM THE ABOVE SCHEDULE AND NOTES, THEN CONTRACTOR SHALL COMPLY W/LOCAL BUILDING AND SAFETY CODES. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS 4 INCHES ON CENTER OR LESS HARDWARE LARR # ICC # JOIST HANGERS 25800 ESR-2553 25801 ESR-2552 25803 ESR-2615 25804 ESR-2551 25807 ESR-2549 POST BASE 25985 ESR-3050 HORIZ. STRAPS 25713 ESR-2105 POST CAPS 25714 ESR-2604 HOLDOWNS 25720 ESR-2330 SIMPSON A35, LTP 25814 ESR-3096 HURRICANE TIES 25718 ESR-2613 SIMPSON SET-XP EPOXY 25744 ESR-2508 HARDWARE LARR # ICC # HARDY FRAME 25759 ESR-2089 STRONG WALL SSW 26625 ESR-1679 STRONG WALL SW 25427 ESR-1267 PARALLAM 25202 ESR-1387 VERSA-LAM 25998 ESR-1040 BCI WOOD I JOIST 24999 ESR-1336 GLASS RAILING 25084 CSI-05520 REDLAM LVL 25832 ESR-2993 QUIK DRIVE 25917 ESR-3006 SD WOOD SCREWS 25910 ESR-3096 SDW WOOD SCREWS 25906 ER-192 ANCHOR BOLTS 25827 ESR-2611 SDS SCREWS 25711 ESR-2236 FOUNDATION REINFORCEMENT DIAPHRAGM AND NAILING FRAMING HARDWARE NAILING AND ANCHORAGE EVGENY NAGOVITSYN 323 486-4151 C93527 1506 E Clemensen Ave & #212/12/2024 DATE REVISIONS BY SEAL FO U N D A T I O N A N D R O O F F R A M I N G P L A N S No 501 S. BRAND BLVD., SUITE 3 SAN FERNANDO, CA 91340 (323)486-4151 STENENGINEERING.COM ROOF SHEATHING 15/32" THICK PLYWOOD C-D EXT INDEX 32 16 W/10d COMMON NAILS @ 6",6",12" O.C. BLOCK ALL UNSUPPORTED PLYWOOD EDGES W/2x4 FLAT BLOCKING, TYPICAL - U.N.O. W/ RADIANT BARRIER FRAMING BOUNDARY SHEAR WALL PER PLAN FRAMING MEMBERS LEGEND: NEW FOUNDATION NOTES 1. ALL STRUCTURAL WOOD SHALL BE DOUGLAS FIR LARCH SPECIES PER INFORMATION SHOWN ON SHEET S-1 WITH 19% MAXIMUM MOISTURE CONTENT U.N.O. 2. ALL WALLS OVER 10' IN HEIGHT TO BE 2X6 @16" O.C. FRAMING. 3. DOUBLE JOISTS ARE REQUIRED UNDER PARALLEL BEARING PARTITIONS. 4. AN AITC CERTIFICATE OF INSPECTION FOR ALL GLU-LAM BEAMS INCLUDING PARALLAM BEAMS SHALL BE SUBMITTED TO THE BUILDING AND SAFETY DEPT. PRIOR TO ERECTION. 5. GLUE LAM BEAMS MUST BE FABRICATED IN A LICENSED SHOP. IDENTIFY GRADE SYMBOL AND LAMINATION SPECIES PER T 5A, 2018 NDS SUPP. 6. FIELD WELDING TO BE DONE BY CERTIFIED WELDERS FOR STRUCTURAL STEEL, CONTINUOUS INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED. 7. SHOP WELDS MUST BE PERFORMED IN A LICENSED FABRICATORS SHOP. 8. LICENSED FABRICATOR IS REQUIRED FOR STRUCTURAL STEEL. 9. ALL WOOD MEMBERS MUST BE GRADE MARKED WITH GRADE AND SPECIES. 10. BEARING WALL STUDS CANNOT BE NOTCHED MORE THAN 25% OF THEIR WIDTH. BORED HOLES CANNOT HAVE A DIAMETER GREATER THAN 40% OF THE STUD WIDTH 11. PROVIDE LEAD HOLE 40%-70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR SMOOTH SHANK PORTION. 12. STRUCTURAL OBSERVATION IS REQUIRED FOR ALL PLYWOOD SHEAR WALLS WITH A DESIGN LOAD OVER 300 PLF. 13. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 14. ROOF DIAPHRAGM NAILING TO BE INSPECTED BEFORE COVERING. FACE GRAIN OF PLYWOOD SHALL BE PERPENDICULAR TO SUPPORTS. FLOOR SHALL HAVE TONGUE AND GROOVE OR BLOCKED PANEL EDGES. PLYWOOD SPANS SHALL CONFORM WITH TABLE 2304.7 15. EXTERIOR STAIRS AND BALCONIES MUST BE POSITIVELY ATTACHED TO THE STRUCTURE WITHOUT THE USE OF TOE NAILS OR NAILS IN WITHDRAWAL. 16. ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. 17. CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A WIND OR SEISMIC FORCE RESISTING SYSTEM/ COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE DBS INSPECTORS AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT PER SEC 1706.1 18. CONTINUOUS SPECIAL INSPECTION REQUIRED BY A REGISTERED DEPUTY INSPECTOR IS REQUIRED FOR FIELD WELDING, CONCRETE STRENGTH F'C>2500 PSI, HIGH STRENGTH BOLTING, SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, PRE-STRESSED CONCRETE, HIGH LOAD DIAPHRAGMS AND SPECIAL MOMENT-RESISTING CONCRETE FRAMES. 19. PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, ANCHORING, AND OTHER FASTENING TO COMPONENTS OF THE SEISMIC FORCE RESISTING SYSTEM. SPECIAL INSPECTION BY A DEPUTY INSPECTOR IS REQUIRED WHERE THE FASTENER SPACING OF THE SHEATHING IS 4 INCHES OR LESS ON CENTER. 20. FASTENERS IN PRESERVATIVE TREATED WOOD OR FIRE RETARDANT WOOD SHALL BE OF HOT DIPPED ZINC COATED GALVANIZED STEEL OR STAINLESS STEEL. 1. ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX. 2. SOLID BLOCKING SHALL BE PROVIDED AT ALL HORIZONTAL JOINTS OCCURRING IN BRACED WALL PANELS 3. ALL SHEAR WALLS WITH A SHEAR VALUE GREATER THAN 340 LB/FT SHOULD BE PROVIDED: a)3x SILL PLATES b) 3x STUDS AND BLOCKS BETWEEN ADJACENT PANELS c) 1/2" EDGE DISTANCE FOR PLYWOOD BOUNDARY NAILING d) ALL PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED. e) STAGGER NAILS IF NAIL SPACING IS LESS THAN 2" O.C. f) SQUARE PLATE WASHERS SHALL BE USED WITH ANCHOR BOLTS 5/8" ∅ BOLT - 3"X3"X1/4" 3/4" ∅ BOLT - 3"X3"X5/16" 7/8" ∅ BOLT - 3"X3"X5/16" 1" ∅ BOLT - 3.5"X3.5"X3/8" SHEET: S2 DRAWN: CHECKED: DATE: SCALE: JOB #: B.O. E.N. N.T.S. EVGENY NA GOVITSY N HOLDOWN ANCHORAGE HOLDOWN MODEL STEMWALL (SDC C-F) SLAB ON GRADE (SDC C-F) MIDWALL/ CORNER ENDWALL MIDWALL/ CORNER ENDWALL HDU 2 SSTB24 SSTB16 SSTB20 HDU4 SB5/8x24 SSTB20 SB5/8x24 HDU5 SSTB24 HDU8 SB7/8x24 PAB7 SSTB28 HDU11 PAB8 SB1x30 HDU14 1. MINIMUM EDGE DISTANCE IS 1 3 4". MINIMUM END DISTANCE IS 5" FOR SSTBs AND THE SB1x30 2. PAB7 ANCHOR BOLTS REQUIRE 10" EMBEDMENT WITH 15" EDGE DISTANCE. PAB8 REQUIRE 12" EMBEDMENT WITH 18" EDGE DISTANCE. 3. SB1x30 REQUIRES 18" WIDE FOOTING. 4. FOR STEMWALL INSTALLATIONS, PAB MUST BE EMBEDDED INTO THE FOOTING. 07/26/24 24-24-456 AD D R E S S : 1 5 0 6 C L E M E N S E N A V E , S A N T A A N A , C A 9 2 7 0 5 OW N E R : N A N C Y C A L T A G I R O N E SEE SHEET S-1 FOR STRUCTURAL OBSERVATION INFORMATION SHEAR WALL SCHEDULE TYPE SHEATHING MATERIAL PANEL NAILING PERIMETER FIELD BLKG. TO PLATE CONNECTION PLATE TO BLKG. CONNECTION ANCHOR BOLTS (U.N.O.) EMBED. DEPTH SHEAR, PLF (LRFD) SHEAR, PLF (ASD) SILL PLATE 1 15/32" PLYWOOD STRUCTURAL 1 10d @ 6" O.C. 10d @ 12" O.C. A35/ LTP4 @ 20" O.C. 20d NAILS @ 6" O.C. 5/8"∅ @ 48" O.C.9" 392 245 2x 2 15/32" PLYWOOD STRUCTURAL 1 10d @ 6" O.C. 10d @ 12" O.C. A35/ LTP4 @ 16" O.C. 20d NAILS @ 4" O.C. 5/8"∅ @ 32" O.C.9" 544 340 3x 3 15/32" PLYWOOD STRUCTURAL 1 10d @ 4" O.C. 10d @ 12" O.C. A35/ LTP4 @ 10" O.C. SDS 1/4"x6" @ 8" O.C. 5/8"∅ @24" O.C.9" 816 510 3x 4 15/32" PLYWOOD STRUCTURAL 1 10d @ 3" O.C. 10d @ 12" O.C. A35/ LTP4 @ 8" O.C. SDS 1/4"x6" @ 5" O.C. 5/8"∅ @ 24" O.C.9" 1064 665 3x 5 15/32" PLYWOOD STRUCTURAL 1 10d @ 2" O.C. 10d @ 12" O.C. A35/ LTP4 @ 6" O.C. SDS 1/4"x6" @ 4" O.C. 5/8"∅ @ 16" O.C.9" 1392 870 3x NOTE: SHEAR PANEL CAN BE INSTALLED ON EITHER SIDE AT CONTRACTOR'S CHOICE 4x4 POST (U.N.O.) FOUNDATION PLAN SCALE: 1/4"=1' ROOF FRAMING PLAN SCALE: 1/4"=1' CJ 2x6 @ 16" O.C. CJ 2x 6 @ 1 6 " O . C . CJ 2x 6 @ 1 6 " O . C . CJ 2x 6 @ 1 6 " O . C . CJ 2x 6 @ 1 6 " O . C . BM 2 6x 8 HDR1 4x6 HDR1 4x6 HDR1 4x6 HDR 4x6 HDR1 4x6 HDR2 4x8 BM 3 3. 5 x 7 P S L 2 . 2 E RIDGE BM2 4x8 RIDGE BM3 4x12 HD R 1 4x 6 HD R 1 4x 6 HD R 1 4x 6 HD R 1 4x 6 2 31 C E D B A 3.5'1 3'1 5'1 1 8' 1 8' 4' 1 4' 1 3.5' 1 3' 1 9.5' 1 11.5' 1 1 22' 1 9' HIP B M 1 4x8 HIP B M 1 4x8 RR 2x6 @ 16" O.C. RR 2x 6 @ 1 6 " O . C . VLY B M 1 4x8 BM1 6x8 BM1 6x8 HIP B M 2 4x8 HIP B M 4 4x1 0 VLY B M 2 4x8 HIP B M 3 4x1 0 HIP B M 2 4x8 HIP B M 5 4x8 HIP B M 5 4x8 RI D G E B M 1 4x 6 RR 2x 6 @ 1 6 " O . C . RR 2x 6 @ 1 6 " O . C . RR 2x6 @ 16" O.C. RR 2x 6 @ 1 6 " O . C . BM 3 3. 5 x 7 P S L 2 . 2 E HDR1 4x6 2 31 C E D B A 3.5'1 3'1 5'1 1 8' 4' 1 4' 1 3.5' 1 3' 1 9.5' 1 11.5' 1 1 22' 1 9' 1 8' 4" CONCRETE SLAB ON GRADE W/#4 @ 16" O.C. EACH WAY @ BOT 10 MIL. VAPOR BARRIER OVER 4" THICK BASE OF 1/2" OR LARGER AGGREGATE (TYP) 4" CONCRETE SLAB ON GRADE W/#4 @ 16" O.C. EACH WAY @ BOT 10 MIL. VAPOR BARRIER OVER 4" THICK BASE OF 1/2" OR LARGER AGGREGATE (TYP) 4" CONCRETE SLAB ON GRADE W/#4 @ 16" O.C. EACH WAY @ BOT 10 MIL. VAPOR BARRIER OVER 4" THICK BASE OF 1/2" OR LARGER AGGREGATE (TYP) 1 S-5 TYP. 5 S-5 TYP. HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 4x6 POST HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 HDU 2 6 S-5 TYP. 4x6 POST 7 S-5 TYP. 8 S-5 TYP. 11 S-5 HUC48 9 S-5 10 S-5 12 S-5 TYP. HUC48 4x4 KING POST 4x4 KING POST 4x4 POST W/ HCP4Z 4x4 POST W/ HCP4Z 4x4 POST W/ HCP4Z 4x4 POST W/ HCP4Z 4x6 POST BC46 4x4 POST W/ HCP4Z 4x4 POST W/ HCP4Z HU68 HU68 4x6 POST W/ BC46 4x6 POST W/ BC46 4x4 POST W/ ECCQ 4x4 POST W/ ECCQ 2 S-5 TYP. 4" CONCRETE SLAB ON GRADE W/#4 @ 16" O.C. EACH WAY @ BOT 10 MIL. VAPOR BARRIER OVER 4" THICK BASE OF 1/2" OR LARGER AGGREGATE (TYP) 2 S-5 TYP. 4x4 POST W/ EPC4Z 4 S-5 TYP. MST60 TOP PL TO RR MST60 TOP PL TO RR RR W/ E.N. RR W/ E.N. 13 S-5 13 S-5 1506 E Clemensen Ave & #212/12/2024 1 1/4"x16 GA. STRAP W/6-10d NAILS EACH END AT EACH PLATE. (STRAP NOT REQUIRED FOR SILL PLATE) 7. 5 " 3.5" MIN.3" MA X . 1. 5 " MA X . (STRAP NOT REQUIRED FOR SILL PLATE) 1 1/4"x16 GA. STRAP W/11-10d NAILS EACH END AT EACH PLATE. 2x8 DOUBLE TOP PLATE 2x8 OR 3x8 SILL PLATE SIMILAR. 1'-0" MIN. MAX. 5.5"1'-0" MIN. 1 1/4"x16 GA. STRAP W/8-10d NAILS EACH END AT EACH PLATE. 2x6 DOUBLE TOP PLATE 2x6 OR 3x6 SILL PLATE SIMILAR. (STRAP NOT REQUIRED FOR SILL PLATE) 2x4 DOUBLE TOP PLATE 2x4 OR 3x4 SILL PLATE SIMILAR. 10" MIN. MAX. 3.5" NOTCHES MIN. 6'-0" O.C. BORED HOLE 3" ∅ MAX. 1'-0" MIN. 6'-0" O.C.2" MA X . 5.5" MAX. 2.5" MIN. 1'-0" MIN. NOTCHES MIN. 2" ∅ MAX. BORED HOLE 5. 5 " BORED HOLE 1 1/4" ∅ MAX. 6'-0" O.C. NOTCHES MIN. 3. 5 " 1.5" 10" MIN. W/ E M B E D . VA R I E S 24" AS R E Q U I R E D DE E P E N F T G . WASHER PLATE HOLDOWN & POST PER PLAN (INSPECTION TO VERIFY) 1/16" + BOLT DIAMETER SECTION A-A BOLT HOLES TO BE EM B E D . MI N . 3 " MIN. 3" 6" PER PLAN HOLDOWN & POST DESIGN INCLUDES REDUCED EDGE DISTANCE DEPUTY INSPECTION IS REQUIRED. MIN 1 3/4" 12"12" 2x SPLICE SCAB SAME DEPTH AS JOIST OR RAFTER W/8-16d NAILS EACH END (TYP) TOP PLATE JOIST OR RAFTER ALTERNATIVE 1/2"x1'-6" LONG PLYWOOD SPLYCE PIECE W/5-10d NAILS EACH END (TYP) PLAN (BUTT SPLICE) 6" TOP PLATE JOIST OR RAFTER W/4-16d NAILS EACH END (TYP) PLAN (LAP SPLICE) 6" B.N. THREADED ROD PER PLAN THREADED ROD SEAL GE N E R A L D E T A I L S DRAWN: CHECKED: DATE: SCALE: JOB #: E.N. T.S. N.T.S. 24-24-456 SHEET: S3 3" MIN 9" MAX 3" MIN 9" MAX MIN 4'-0" PLATE SPLICE W/14-16d NAILS U.N.O. ON PLAN 3x BLOCKING TYP. (SEE NOTE 1) OPENING HEADER UP TO 6'-0"4x6 6'-0" TO 8'-0"4x8 4x10 WIDTH 8'-0" TO 10'-0" HEADER SCHEDULE 2-16d FACENAIL STUD TO HEADER MST 37 WHERE INDICATED ON PLAN NOTES 1. HEADERS, KINGSTUDS AND OTHER REFERENCES ON PLAN GOVERN OVER TYPICAL DETAIL. 2. SEE SHEAR WALL PLYWOOD NAILING DETAIL FOR ADDITIONAL INFORMATION. 3. AT WOOD FRAMED WALLS USE SILL CONNECTION PER SHEAR WALL SCHEDULE. SEE SHEAR TRANSFER SECTION OR PLAN 5/8"∅x12" A.B. PER SHEAR WALL SCHEDULE OR 4'-0" O.C. MAX (SEE NOTE 3) 16d FACENAILS @ 12" O.C. MULTIPLE STUD FULL LENGTH PROVIDE DOUBLE KINGSTUD OR 4x POST WHERE OPENING EXCEEDS 8'-0" HEADER PER SCHEDULE OR PLAN 2-16d FACENAIL THRU ONE PLATE TO STUD 2x STUDS @ 16" O.C. SEE PLAN 2x BLOCKING @ 4'-0" HEIGHT W/2-16d TOENAIL EACH END 2x TRIMMER AND KING STUD PRESSURE TREATED SILL PLATE TOP OF SLAB OR SHEATHING 2-16D FACENAIL OR 2-8D TOENAIL EACH SIDE OF STUD TYPICAL WALL FRAMING FOR BEARING WALLS 1 3" MIN 9" MAX 3" MIN 9" MAX MIN 4'-0" PLATE SPLICE W/16-16d NAILS U.N.O. ON PLAN 2 3TYPICAL WALL FRAMING FOR NON BEARING WALLS 3x BLOCKING TYP. 2-16d FACENAIL STUD TO HEADER 16d FACENAILS @ 12" O.C. MULTIPLE STUD FULL LENGTH PROVIDE DOUBLE KINGSTUD OR 4x POST WHERE OPENING EXCEEDS 6'-0" HEADER PER SCHEDULE OR PLAN 2-16d FACENAIL THRU ONE PLATE TO STUD 2x STUDS @ 16" O.C. SEE PLAN 2x BLOCKING @ 4'-0" HEIGHT W/2-16d TOENAIL EACH END 2x TRIMMER AND KING STUD PRESSURE TREATED SILL PLATE TOP OF SLAB OR SHEATHING 2-16D FACENAIL OR 2-8D TOENAIL EACH SIDE OF STUD SEE SHEAR TRANSFER SECTION OR PLAN 0.145"∅ POWDER DRIVEN ANCHOR W/1 3/8" WASHER AND 1" EMBEDMENT AT 24" O.C. AND 6" FROM END OF PLATE (SEE NOTE 2) OR PER STRUCTURAL DETAILS (SEE NOTE 1) OPENING HEADER UP TO 4'-0"4x4 6'-0" TO 8'-0"4x6 4x10 WIDTH 8'-0" TO 10'-0" HEADER SCHEDULE NOTES 1. HEADERS, KINGSTUDS AND OTHER REFERENCES ON PLAN GOVERN OVER TYPICAL DETAIL. 2. NAIL SILL PLATE TO WOOD FRAMED FLOORS WITH 16D @ 3" O.C. TO BLOCKING BELOW SHEATHING OR PER STRUCTURAL DETAILS. WIRE TIES TYPICAL DOWELS OR BAR FROM BELOW 40 D I A M SLOPE 1:6 MAX FOR COLUMN REINFORCEMENT NOTES 1. ALL VERTICAL REINFORCING FOR COLUMNS, PIERS AND WALLS SHALL BE DOWELED AS SHOWN EXCEPT SPECIFIC DETAILS ON DRAWINGS SHALL GOVERN IN CASES OF CONFLICT. 2. DOWELS SHALL BE THE SAME GRADE, SIZE AND NUMBER AS VERTICAL REINFORCING. VERTICAL REINFORCEMENT LAP SPLICE 6d OR 4" MIN 135° HOOKS TIE OR STIRRUP PRINCIPAL REINFORCING 90° HOOK ACI-318 CODE NOTE: FOR D ETC SEE GOVERNING EDITION. 180° HOOK 1 6 MAX OFFSET BEND D d Dd 2 1/2" MIN 4d OR / 12d NOTES 1. ALL BENDS SHALL BE MADE COLD 2. #14 & #18 BARS SHALL BE BEND-TESTED AND APPROVED PRIOR TO BENDING 3. USE MAXIMUM OF 48d & 24" FOR LAP SPLICE 4'-0" MIN. LAP 16d AT 9", STAGGERED E.S. OF TOP PLATE SPLICE 2-16d TOP PLATE SPLICE TOP PLATES STUDS 2-16d E.N. E.N. MIN 4x POST COUNTERSINK NUT & WASHER IN KING STUD 2-16D @ 3" O.C. FULL HEIGHT K.S. TO POST HOLDOWN PER PLAN 2x10 & UP 3x10 & UP 2x8 1 9/16 2 9/16 LSSU28 LSSU210-2 LSSUH310 LSSU210 1 9/16 4x10 & UP 3 9/16LSSU410 (2)2x10 & UP 3 1/8 7-10dx1 1/2 12-10dx1 1/2 5-10dx1 1/2 18-16d 18-16d 10-10d 10-10d 12-10dx1 1/218-16d 12-10dx1 1/2 8 1/2 8 1/2 8 1/2 8 1/2 7 1/8 DIMENSIONS SIZE JOISTSIMPSON MODEL 2x6 1 9/16LSU26 WNO. FASTENERS 5-10dx1 1/26-10d4 7/8 JOISTHEADERH JOIST PER PLAN NAILS PER TABLE SHEATHING JOIST PER PLAN SHEATHING HEADER OR BM PER PLAN JOIST/RAFTER PER PLAN LSU/LSSU AS SPECIFIED NAIL PER TABLE LSU/LSSU AS SPECIFIED HEADER OR BM PER PLAN SIMPSON HOLDOWN HDU2-SDS 2.5 SET 10"5/8"∅ THREADED ROD REQUIRED EPOXY-TIE AD4 MINIMUM EMBEDMENTANCHOR SECTIONELEVATION WALL OR FTG WIDTH 6" MIN STEMMINMIN 5"1 3/4" FOUNDATION CONCRETE TA B L E EM B E D P E R P.T. SILL PLATE STUD OR POST PER PLAN TRIMMER STUD (AS REQ'D) DESIGN INCLUDES REDUCED EDGE DISTANCE DEPUTY INSPECTION IS REQUIRED. HDU4-SDS 2.5 SET 15"5/8"∅ THREADED ROD HDU5-SDS 2.5 SET 15"5/8"∅ THREADED ROD HDU8-SDS 2.5 SET 20"7/8"∅ THREADED ROD HDU11-SDS 2.5 SET 20"1"∅ THREADED ROD HDU14-SDS 2.5 SET 24"1"∅ THREADED ROD PHD2-SDS 3 SET 10"5/8"∅ THREADED ROD PHD5-SDS 3 PHD6-SDS 3 HDQ8-SDS 3 HHDQ11-SDS 4.5 HHDQ14-SDS 4.5 HDG10/4-SDS 4.5 7/8"∅ THREADED ROD 7/8"∅ THREADED ROD 7/8"∅ THREADED ROD 1"∅ THREADED ROD 1"∅ THREADED ROD 5/8"∅ THREADED ROD 15" 15" 20" 20" 20" 20" SET SET SET SET SET SET ALL HARDY FRAME 1" OR 1 1/8"∅ 18"SET THREADED ROD HOLDOWN AS SPECIFIED, SEE TABLE AND APPLICABLE DETAIL SIMPSON ANCHOR W/EPOXY-TIE ADHESIVE PER TABLE 87654BAR BENDS & SPLICE LENGTH TYPICAL STUD WALL TOP PLATE SPLICE DETAIL LSU/LSSU HANGER DETAILS EPOXY-TIE HOLDOWN ANCHOR 1" DIM FOR POST PLACEMENT 4x4 1 1/4 HDU4 HDU2 MINIMUM POST SIZE 'CL' SIMPSON HOLDOWN 5/8" 7/8" 1" HOLDOWN ANCHOR DIAMETER ELEVATION P.T. SILL PLATE MIN5" TRIMMER STUD (AS REQ'D) PLAN 1 3 / 4 " M I N DESIGN INCLUDES REDUCED EDGE DISTANCE DEPUTY INSPECTION IS REQUIRED. 5/8" THREADED ROD 1"∅ THREADED ROD HOLDOWN ANCHOR STUD BOLTS 30-SDS 1/4"x2.5 6-SDS 1/4"x2.5 5/8" 5/8" 1"∅ THREADED ROD 4x4 1 1/4 5/8" THREADED ROD 10-SDS 1/4"x2.5 HDU5 4x4 1 1/4 5/8" THREADED ROD 14-SDS 1/4"x2.5 HDU8 4x6 1 1/4 7/8" THREADED ROD 20-SDS 1/4"x2.5 HDU11 4x6 1 1/4 HDU14 4x8 1 9/16 36-SDS 1/4"x2.5 5/8" 5/8" THREADED RODPHD24x4 1 3/8 10-SDS 1/4"x3 5/8" 5/8" THREADED RODPHD54x4 1 3/8 14-SDS 1/4"x3 5/8" 5/8" THREADED RODPHD64x4 1 3/8 18-SDS 1/4"x3 7/8" 5/8" THREADED RODHDQ84x6 1 1/2 20-SDS 1/4"x3 1" 1"∅ THREADED RODHHDQ114x6 1 1/2 24-SDS 1/4"x2.5 1" 1"∅ THREADED RODHHDQ144x8 1 1/2 30-SDS 1/4"x2.5 7/8" 7/8" THREADED RODHDG10/4 4x4 1 13/16 24-SDS 1/4"x2.5 PROVIDE SHEAR WALL BOUNDARY NAILING INTO HOLDOWN POST SHEAR WALL AS OCCURS SHEATHING & NAILING PER PLAN STUD OR POST PER PLAN PROVIDE STANDARD WASHERS. FOR DEFLECTION CRITICAL APPLICATIONS USE SIMPSON BP BEARING PLATES, TYP. HOLDOWN ANCHOR OR SIMPSON SSTB PER TABLE STUD BOLTS PER TABLE SIMPSON HD HOLDOWN PER PLAN CONCRETE FOUNDATION MSTC28 MSTC40 MSTC52 F H G 36-16d SINKERS 70-16d SINKERS 54-16d SINKERS MST27 MST48 MST60 MST72 MST37 A E B C D 30-16d 56-16d 56-16d 46-16d 42-16d PIECE SIMPSON MARK PIECE FASTENERS EQ EQ EQ EQ SIMPSON STRAP AS SPECIFIED. SEE TABLE FOR REQUIRED FASTENERS HEADER/DRAG MEMBER PER PLAN TRIMMER STUD(S) PER PLAN SHEARWALL BOUNDARY STUDS OR POST PER PLAN NOTE: PLACE NAILS STARTING @ CENTER OF STRAP & WORK OUT TO EACH END. ELEVATION SIZE FASTENERS 8d x 1 1/2" 8d x 1 1/2" 8d x 1 1/2"A35DBL TOP PLATE LTP4 BLOCKING MODEL NO. SIMPSON A34 12 12 8 NO. SHEATHING PER PLAN BOUNDARY NAILING PER PLAN BLOCKING OR RIM JOIST PER PLAN EDGE NAILING SHEARWALL SHEATHING AS SPECIFIED FIELD NAILING, TYP SIMPSON A34 OR A35 AS SPECIFIED DOUBLE TOP PLATE STUD PER PLAN SHEATHING PER PLAN BOUNDARY NAILING PER PLAN BLOCKING OR RIM JOIST PER PLAN SIMPSON A34 OR A35 AS SPECIFIED FIELD NAILING, TYP SHEARWALL SHEATHING AS SPECIFIED EDGE NAILING STUD PER PLAN DOUBLE TOP PLATE SHEATHING PER PLAN BOUNDARY NAILING PER PLAN BLOCKING OR RIM JOIST PER PLAN BLOCKING OR RIM JOIST PER PLAN LPT4 MAY BE INSTALLED OVER PLYWOOD. PROVIDE FULL LENGTH 8d COMMON NAILS THROUGH PLYWOOD. SHEARWALL SHEATHING AS SPECIFIED FIELD NAILING, TYP EDGE NAILING STUD PER PLAN DOUBLE TOP PLATE SIMPSON LTP4 AS SPECIFIEDJOIST OR RAFTER PER PLAN PLYWOOD/OSB SHEATHING PER PLAN. SEE SHEARWALL SCHEDULE AS REQUIRED FOR NAILING 2x STUD CORNER CONDITION HDU2, PHD2 HDU8, PHD6, PHD87/8 PLAN OR DETAILS SIMPSON SSTB PER MIN. REBAR LENGTH PER TABLE END CONDITION PE R P L A N M I N 1 3 / 4 " ST E M W A L L PE R P L A N ST E M W A L L Le P E R T A B L E EM B E D M E N T L E N G T H INSTALL SSTB @ 45° TO STEM WALL 45° SECTION MIN 5" NO.Le SSTB24 SSTB16 SSTB28 64" 48"5/8 5/8 6" 6" 20" 12" TYP END 52" 36" 72"8" 24" 60" MODEL SIMPSON LENGTHDIA EMBEDSTEM MIN REBARMINMIN TYPICAL CONDITION LONGITUDINAL REINFORCING IN STEM WALL, SEE PLAN OR DETAILS (#4 MIN) MIN. REBAR LENGTH PER TABLE 4 SS T B FO R 7 / 8 " ∅ 12 " M I N SIMPSON SSTB PER PLAN OR DETAILS INSTALL SSTB @ 45° TO STEM WALL 45°SIMPSON SSTB PER PLAN OR DETAILS MIN 3" MIN 5" MIN 30" REBAR LENGTH SSTB34 80"7/8 8" 28" 68"HDC 10/4 APPLICABLE SIMPSON HOLDOWN HDU2, HDU4, HDU5, PHD2, PHD5 SLAB @ DOUBLE POUR CONCRETE AS OCCURS EMBEDMENT LINE IS NOTED ON SSTB MIN STEM PER TABLE MIN 1 3 4" 5" M A X 3" M I N REBAR PER PLAN #4 MIN (NOTE: SSTB DOES NOT NEED TIE TO REBAR) CONCRETE STEM WALL & FOOTINGS PER PLAN 11109HD AT FOUNTATION (CORNER CONDITION)'MST' DRAG STRUT HEADER TO TOP PLATE SHEAR TRANSFER DETAIL STEM WALL PER PLAN ST E M W A L L PE R P L A N 12SSTB ANCHOR INSTALLATION 1514TYPICAL NOTCH DETAIL13DEEPENED FOOTING FOR THREADED ROD INSTALLATION 501 S. BRAND BLVD., SUITE 3 SAN FERNANDO, CA 91340 (323)486-4151 STENENGINEERING.COM WALLS INTERSECTIONS JOIST/RAFTER SPLICE AD D R E S S : 1 5 0 6 C L E M E N S E N A V E , S A N T A A N A , C A 9 2 7 0 5 OW N E R : N A N C Y C A L T A G I R O N E 07/26/24 EVGENY NA GOVITSY N 1506 E Clemensen Ave & #212/12/2024 SEAL GE N E R A L D E T A I L S 501 S. BRAND BLVD., SUITE 3 SAN FERNANDO, CA 91340 (323)486-4151 STENENGINEERING.COM 14. STUCCO AND/OR STUCCO WITH VENEER OVER A PLYWOOD SHEAR WALL WILL BE WATERPROOF WITH A MINIMUM 2-#15 FELT UNDERLAYMENT. 15. ONLY COMMON NAILS WILL BE USED FOR ALL PLYWOOD SHEAR WALLS AND NAIL GUNS USING "CLIPPED HEAD" OR "SINKER" NAILS ARE NOT ACCEPTABLE. B. PROVIDE 3x STUDS BETWEEN ADJACENT PANELS. IF IT IS NECESSARY TO USE 2-2x MEMBERS BETWEEN PANELS, USE 16d NAILS W/STAGGERED NAILING 16. ALL BOLT HOLES TO BE DRILLED 1/32" MINIMUM TO 1/16" MAXIMUM OVERSIZED. A. PROVIDE 3x SILL PLATES FOR SILLS THAT REST ON CONCRETE OR MASONRY. 17. THE FOLLOWING APPLIES TO ALL SHEAR WALLS WITH A LISTED DESIGN LOAD GREATER THAN 300 PLF: D. PLATE WASHERS ARE TO BE USED WITH ANCHOR BOLTS. 3/4" BOLT-3"x3"x5/16" 1/2" BOLT-3"x3"x3/16" C. PROVIDE 1/2" EDGE DISTANCE FOR THE PLYWOOD BOUNDARY NAILING. & SPACING NO GREATER THAN THE REQUIRED PLYWOOD EDGE NAILING. 7/8" BOLT-3"x3"x3/8" 5/8" BOLT-3"x3"x1/4" BY OPENINGS; TRIPLE RAFTERS WHERE 3 WHERE 2 RAFTERS SPANS ARE INTERUPTED STANDARD APPROVED JOIST HANGER PER SCHEDULE STANDARD APPROVED (TYP.) HEADER 2-2x DOUBLE JOIST HANGER (TYP.) (TYP.) OPENING AROUND B.N. 3 SPACES (MAX.) RAFTERS SPANS ARE INTERUPTED PROVIDE (TYP. EA. SIDE) DBL RAFTERS 11. SPACING OF A35, 16d NAILS, AND ANCHOR BOLTS IS TO BE REDUCED BY 1/2, IF PLYWOOD SHEATHING OCCURS ON BOTH SIDES OF WALL. ANCHOR BOLT SPACING 10. THIS NAILING SCHEDULE IS FOR COMMON NAILS. THIS IS IN ADDITION TO THE MINIMUM NAILING REQUIRED BY UBC TABLE 25-Q; AND THE CITY BUILDING AND 13. NAIL SPACING BELOW 4" O.C. SHALL HAVE A PRE-DRILLED HOLE, WHEN USED, WHICH CAN NOT EXCEED 75% OF THE NAIL DIAMETER (BUT SHOULD BE AS 12. WHERE PLYWOOD IS APPLIED ON BOTH SIDES OF A WALL AND NAIL SPACING IS LESS THAN 6" O.C. EITHER SIDE. THIS IS IN ADDITION TO THE MINIMUM NAILING REQUIRED BY UBC TABLE 25-Q; PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS OR FRAMING SHALL BE 3-INCH (76 mm) 9. STRUCTURAL WOOD PANEL SHEAR WALLS SHALL BE COVERED WITH MINIMUM 2 LAYERS 15# FELT UNDERLAYMENT PRIOR TO PLACING FINISH MATERIAL. 7. WHERE THERE IS LIGHT WEIGHT CONCRETE TOPPING 3x SOLE PLATE MAY BE REPLACED BY DOUBLE 2x (USE 3/8" ∅ LAG BOLT AT MINIMUM 16" O.C. FOR 1 & 2 5. USE 3x P.T. SOLE/SILL PLATE THAT RESTS ON CONCRETE OR MASONRY FOR SHEAR WALL 2 AND ABOVE. TYPICAL UNLESS NOTED OTHERWISE. 1. USE COMMON NAILS ONLY U.N.O. HEREIN. SINKER NAILS NOT PERMITTED. SEE GERNEAL NOTES "FRAMING LUMBER" FOR LUMBER MOISTURE CONTENT. THERE SHALL BE A MINIMUM PENETRATION OF 1.94" AND 1.78" INTO NAILED MEMBERS FOR 16d AND 10d NAILS RESPECTIVELY. (20d BOX NAILS WITH 1.94" MINIMUM 3. ALL ANCHOR BOLT WASHERS TO BE 1/4" PL. x3 SQ. NO STANDARD CUT WASHERS PERMITTED. SAFETY DEPARTMENT MEMO, NOVEMBER, 1994. USE COMMON NAILS ONLY. SEE ADDITIONAL SHEAR WALL NOTES. CLOSE TO 75% AS POSSIBLE). UNSEASONED LUMBER IS ASSUMED TO BE USED. NOMINAL OR THICKER AND NAILS ON EACH SIDE SHALL BE STAGGERED. SHOWN ON FOUNDATION PLAN IS MINIMUM, UNLESS NOTED OTHERWISE. 8. PROVIDE PRE-BORED HOLES FOR ALL LAG BOLTS AND 20d NAILS. 6. PROVIDE 4" PENETRATION INTO FRAMING FOR 3/8" ∅ LAGS AND 5" PENETRATION FOR 1/2" ∅ LAGS. 4. ANCHOR BOLTS SHALL HAVE A MINIMUM 9" EMBEDMENT INTO CONCRETE. PENETRATION SHALL BE USED FOR SOLE PLATE NAILING). 2. ALL PLYWOOD EDGES TO BE BLOCKED. PROVIDE MINIMUM OF 1/2" EDGE DISTANCE FOR THE NAILING TO 3x MEMBERS. CORNER @ E.A. ST2215 L L/3 L/3 L/3 D/6 D/6 D 2" 2"D/4 D D D D/3 D/6 D D NOMINAL ACTUAL D/6 D/4 D/3 6" 5 1/2" 7/8" 1 3/8" 1 13/16" 8" 7 1/4" 1 13/16" 1 13/16" 2 7/16" 10" 9 1/4" 1 1/2" 2 5/16" 3 1/16" 12" 11 1/4" 1 7/8" 2 13/16" 3 3/4" 14" 13 1/4" 2 3/16" 3 5/16" 4 7/16" NOTES: 1) D= JOIST OR RAFTER DEPTH L= JOIST OR RAFTER LENGHT 2) CROSS HATCHING INDICATES AREA WHERE NOTCHES OR HOLES ARE NOT ALLOWED. 3) PREFERRED LOCATION OF NOTCH IS AT TOP OF MEMBER. 1/16" SPACE (TYP.) 1 1/2" 3/8" MIN. 3" OR GREATER 2 1/2"2 1/2" 2" AD JOINING PANELS 6" NAILING - 2x FRAMING 3" OR GREATER NAIL'G 3x FRAMING AD JOINING PANELS 2" STAGGERED NAIL'G 3x FRAMING AD JOINING PANELS- 4" OR LESS NAILING 1 1/2"2 1/2" 6" NAILING 2x FRAMING TYP. BOUNDARY NAIL TYP. BOUNDARY NAIL 4" OR LESS NAILING 3x FRAMING 6" 1/2" EDGE DIST. TYP. 3/16"1/2"1"1/2" 1/47/16 5/16 5/161/2 3/8 RED WOOD NOT REQ.1/4, 5/16, 3/8 SCREW NOT REQ. DOUG. FIR LEAD HOLE LAG SCREW ASSEMBLY DIAMETER (IN.) DIAMETER (IN.) & SO. PINE 5/8 7/16 3/8 7/161/23/4 1/25/87/8 5/83/41 SHANK LENGHT LEAD HOLE LENGHT SHANK DIAM. PROVIDE 15/64" ∅ LEAD HOLES FOR 1/2" LAG SCREWS. LAG SCREWS SHALL NOT BE DRIVEN. HOLES FOR 3/8" LAGS DO NOT REQUIRE PREDRILLED LEAD HOLES. AND INCREASE LENGHT OF SDS SCREWS BY 1". BN BNBN SHEAR WALL PER PLAN KING STUD TRIMMER STUD COUNTERSINK NUT AND WASHER IN KING STUD HOLDDOWN PER PLAN MIN 4x4 POST (U.N.O.) SHEAR WALL POST BN SHEAR WALL KING STUD PER PLAN BNBN BN PER SCHEDULE HOLDDOWN BOLT PER SCHEDULE HOLDDOWN BOLT PER PLAN HOLDDOWN BN BN BN PER PLAN SHEAR WALL 2-16d NAILS @ 3" O.C. FULL HEIGHT AND WASHER IN KING STUD COUNTERSINK NUT 2x STUD W/16d NAILS @ 6" O.C. OR 3x STUD W/16d NAILS @ 8" O.C. AND WASHER IN KING STUD 2x STUD COUNTERSINK NUT HOLDDOWN PER PLAN SHEAR WALL POST MIN 4x4 POST (U.N.O.) HOLDDOWN BOLT PER SCHEDULE PER PLAN SHEAR WALL BNBN FULL HEIGHT 2-16d NAILS @ 3" O.C.BNBN KING STUD W/16d NAILS @ 8" O.C. 2x STUD 16d NAILS @ 8" O.C. TYPICAL W/16d NAILS @ 8" O.C. 2x STUD TYPICAL 16d NAILS @ 8" O.C. BN PER PLAN SHEAR WALL POST MIN 4x4 POST (U.N.O.) HOLDDOWN PER SCHEDULE PER PLAN SHEAR WALL BNBN HOLDDOWN BOLT 16d NAILS @ 3" O.C. PER PLAN SHEAR WALL PER PLAN SHEAR WALL BN BN BN BN SHEAR WALL BN PER PLAN MIN 4x4 POST (U.N.O.) PER PLAN SHEAR WALL BN 20d NAILS @ 3" O.C. BN BN SHEAR WALL POST BN HOLDDOWN PER PLAN PER SCHEDULE HOLDDOWN BOLT BN PER PLAN SHEAR WALL BN SHEAR WALL BN PER PLAN MIN 4x4 POST (U.N.O.) PER PLAN SHEAR WALL BN 16d NAILS @ 3" O.C. BN SHEAR WALL POST BN HOLDDOWN PER PLAN PER SCHEDULE HOLDDOWN BOLT PER PLAN SHEAR WALL BN DO NOT INTERRUPT PLYWOOD SHEATHING (DO NOT CUT PLYWOOD) NO NAILS W/SDS1/4"x5" @ 6" O.C. W/SDS1/4"x5" @ 6" O.C. W/16d NAILS @ 6" O.C. OR 3x STUD 2x STUD W/SDS1/4"x5" @ 6" O.C. W/16d NAILS @ 6" O.C. 2x STUD OR 3x STUD BN BN OR 3x STUD W/16d NAILS @ 6" O.C. W/SDS1/4"x5" @ 6" O.C. 2x STUD OR 3x STUD W/16d NAILS @ 6" O.C. W/SDS1/4"x5" @ 6" O.C. 2x STUD W/16d NAILS @ 6" O.C. W/SDS1/4"x5" @ 6" O.C. OR 3x STUD 2x STUD PLYWOOD FLOOR ROOF LOCATION 5/8" 3/4" PANEL ID 24/16 40/20 BOUND. NAILS 10d @ 6" 10d @ 4" EDGE NAILS 10d @ 6" 10d @ 6" FIELD NAILS 10d @ 12" 10d @ 12"SEE SCHEDULE FOR BOLTS WOOD POST PER PLAN SEE STRUCTURAL DETAILS FOR EMBEDMENT IF OCCURS POST PER PLAN MIN 4x4 12" MAX PER SHEAR WALL SCHED. PER HOLDOWN SCHEDULE ANCHOR BOLT OR SSTB 2x OR 3x TREATED SILL 12" MAX NAILING W/BOUNDARY ALL AROUND 2x BLOCKIG MIN 12" E.N. 1'-4" MIN. 3/8" EDGE DISTANCE TYP. (1/2" @ 3x SILL PLATE) ANCHOR BOLT OR SSTB PER HOLDOWN SCHEDULE A PLYWOOD BOTH SIDES 3x STUD MIN. JOINTS ON OPPOSITE SIDES WITH WHERE PLYWOOD SHEATHING OCCURS ON BOTH SIDES OF WALL, STAGGER PLYWOOD EDGE 3x STUD, MIN. EDGE NAIL EDGE NAIL HOLES CUT WITH RADIUS AT EACH CORNER IN SHEAR WALLS AND STRAP ACCROSS CIRCULAR BORED HOLES OR SQUARE7. PLYWOOD EDGE KING POST ABOVE 2x TRIMMER HEADER AND TO 4x POST @ 3" O.C. W/16d NAILS HEIGHT STUD FULL 4x POST EDGE OF PLYWOOD END OF SHEAR WALL MEMBERS TEND TO SPLIT ADD BLKG AROUND ALL OPENINGS OPENINGS IN A SHEAR PANEL SHALL NOT EXCEED 20% OF THE PANEL LENGTH MAXIMUM ACCUMULATED LENGTH OF RETIGHTEN NUTS BEFORE COVERING 6. 5. 4. ALL NAILS SHALL BE COMMON WIRE NAILS SEE TIMBER NOTES FOR PLYWOOD GRADE PRE-DRILL HOLES FOR NAILS WHERE NOTES: 2x TRIMMER MIN 4x4 POST 3. 1. 2. At existing conc. footing use all thread anchor bolt w/simp. ET22 epoxy w/15" min. embd. & 3 ∅ Provide 3x sill pl. (p.t.) for sills that rest on concrete or masonry for walls At raised wood floor use 3x sill pl. for floor sill & mud sill at wall inverted HD at top of cripple wall & a third holdown at sill pl. of cripple to footing Where cripple wall below is higher than 36", use HD at base of shear wall connected to an Simp A35 or A35F per shear wall sched at blk'g/sill pl. similar at dbl. top pl./blk'g the above shall not be req'd where wall sheathing extend over blk'g w/boundary nailing @ wall sill pl. or dbl. pl. to A307 steel anchor bolts X 9" embd. min. spaced as per s.w.s. (edge dist.=3 ∅ min.) At existing cont. footing use all-thread A.B. w/9" embd. w/simp. epoxy ET22 RR#25185 (3 ∅ ECCQ PER PLAN ECCQ 3x blk'g/rim joist @ wall 2-5/8"∅ MB PER PLAN FULL HEIGHT OF WALL HOLD-DOWN POST min edge distance) Use square washers as per "4.D" of shear wall notes for wall lower pl. or upper pl. 4x4 POST 2x blk'g/rim joist @ wall Use 20d nails @ 4" o.c. @ wall hole on this sheet For mechanical penetration thru-wall pl. see max. allow bored Use lag screw per shear wall sched. at walls HEADER MIN 4x4 POST Holdown anchor bolt per ICBO & RR for embd. A.B. edge distance shall be 3 ∅ min. edge distance RR#25185 into 3x blk'g. 2x4 studs @ 16" o.c. (10' max.) otherwise 2x6 @ 16" o.c. (u.n.o.) @ panel edges & sill w/boundary No substitution of plywood unless a written approval by engineer of record is obtained UNDER POST SOLID 4x BLOCKING UNDER POST SOLID 4x BLOCKING Square washer per shear wall notes Plywood face grain may be horz. or vert. 1/2" thick struc I plywood (4 plys min.) See note 4 of shear wall sched Holdown where occurs w/4x post min (or 2-2x4 for retrofit).UNDER POST SOLID 4x BLOCKING Boundary nailing at panel edges, common nails only Field nailing @ 12" o.c., common nails only 2x blk'g @ 3x blk'g @ nails & 1/2" minimum edge distance 3x studs @ Dbl stud @ 1 2 3 4 Dbl top plate 2x STUDS PLATE WASHER PER SCHEDULE COUNTERSINK NUT AND WASHER IN STUD 16d NAILS @ 3" O.C. STRUCTURAL SLAB OR FOOTING FOR ANCHOR BOLT SEE SCHEDULE SIMPSON HOLDOWN SEE PLAN FOR TYPE NUT AND WASHER PER PLAN JOIST SEE PLAN FOT SPACING SEE SCHEDULE EXTERIOR WALL NAILING (B.N.) BOUNDARY TO A D J A C E N T 4' - 0 " L A P T Y P . PA N E L 8' - 0 " L O N G P A N E L - T Y P . NAILING FIELD NAILING EDGE 4'-0" WIDE PANEL TYP. 2x BLOCKING WHERE BLOCKED DIAPHRAGM IS SHOWN ON PLAN OR T&G PLYWOOD EDGE NAILING 2 NAILS @ JOIST IF OCCURS PLATE WASHER (TYP) PER HOLDOWN SCHEDULE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1"1" 1 3/4"1 3/4" 1" 5 1/4" 3/8" THICK PLATE5 1/4" 42" 6-1/2"∅ LAGS MIN 2 1/2 EMB INTO BLOCKING OR RIM JOIST GLASS PANEL TRACK AND CONNECTION FULL PEN WELD ALL AROUND TS 3"x3"x1/4" TUBE STEEL PER MANUFACTURER GLASS PANEL TRACK AND CONNECTION PER MANUFACTURER 1"LARR# 25374 LARR# 25374 20d NAILS OR SDS SCREWS PER SHEAR WALL SCHEDULE HOLDOWNS PER PLAN SAME SIZE HOLD-DOWN POST AS OCCUR. SEE PLAN STRAP PER PLAN CMST12 STRAP CUT TO LENGTH 2x OR 3x SILL PER SHEAR WALL SCHEDULE PLYWOOD FLOOR SHEATHING PER PLAN EDGE NAIL (EN) INDIVIDUAL PIECES OF PLYWOOD SHALL NOT BE LESS THAN 2'-0" IN LEAST DIMENSION, NOR 8'-0" SQ.FT. IN AREA. 2x OR 3x STUD @ PLYWOOD EDGES PER SHEAR WALL SCHEDULE 2x OR 3x BLKG, TYP. PER SHEAR WALL SCHEDULE 2X STUD WALL W/ PLYWOOD SHEATHING PER PLAN AND SHEAR WALL SCHEDULE PLATE WASHER TYP. AT BOLT LOCATIONS ANCHOR BOLT PER PLAN AND SHEAR WALL SCHEDULE 1 2 3 4 2 3 4 2 3 4 1 2 3 4 1 2 3 4 2 3 4 1WOOD SHEAR WALL CONSTRUCTION DETAIL SHEARWALL BOTTOM CONNECTION 2x BLOCKING @ 48" O.C. PER SCHEDULE B.N. PER PLAN FLOOR JOIST B.N.SHEATHING FLOOR ANCHOR BOLTS PER SCHEDULE B.N. PER PLAN SHEARWALL B.N. P.T. SILL PLATE PER SCHEDULE PER SCHEDULE ANCHOR BOLTS SOLE PLATE PER SCHEDULESHEARWALL SHEARWALL TOP CONNECTION WHERE OCCURSSHEARWALL PER PLAN (OR LTP4 OPTIONAL) A35 PER SCHEDULE STEM MIN 8" CONCRETE OR MASONRY B.N.FLOOR JOISTS PER PLAN6 6 1112 14 6 11 6 15 11 6 15 2 2x OR 3x STUDS 2 RIM JOIST 2x FOR 3x FOR SHEAR WALL1 2 3 4 FLOOR JOIST IF OCCURS 2x OR 3x STUDS 2 PER PLAN FOUNDATION 15 PLYWOOD B.N.B.N.SHEATHING WHERE OCCURS PER PLAN SHEARWALL PER SCHEDULE NAILS OR SCREWS 2x OR 3x STUDS 2WHERE OCCURS 2x OR 3x STUDS WHERE OCCURS (OR LTP4 OPTIONAL) A35 PER SCHEDULE 14 2x OR 3x STUDS 2 PER PLAN SHEARWALL PER SCHEDULE NAILS OR SCREWS FLOOR JOIST IF OCCURS SHEARWALL PER PLAN 2x BLOCKING FOR SHEAR WALL 3x BLOCKING FOR SHEAR WALL 1 2 3 4 FLOOR FRAMING 12 2x BLOCKING FOR SHEAR WALL 3x BLOCKING FOR SHEAR WALL 1 3 4 PER PLAN FLOOR JOISTFLOOR JOIST IF OCCURS (OR LTP4 OPTIONAL) A35 PER SCHEDULE 14 PER SCHEDULE NAILS OR SCREWS12 SHEATHING FLOOR 2WHERE OCCURS 2x OR 3x STUDS 2TYPICAL SHEAR TRANSFER DETAIL RAISED FLOOR OR 3x STUD W/16d NAILS @ 6" O.C. W/SDS1/4"x5" @ 6" O.C. 2x STUD 3TYPICAL WALL INTERSECTION (E.N.) 4ROOF AND FLOOR DIAPHRAGM NOTES: 1. O.S.B. OF SAME THICKNESS AND NAILING MAY BE SUBSTITUTED IN LIEU OF PLYWOOD. 2. USE BOUNDARY NAILING AT ALL HIPS, RIDGES, VALLEYS AND OPENINGS. 3. USE COMMON NAILS FOR ALL DIAPHRAGM NAILING. 4. PLYWOOD SHALL BE GLUED FOR FLOORS. PLYWOOD SHALL BE T&G FOR BALCONIES AND CATWALKS. DIAPHRAGM SCHEDULE 5 6NOTCHING AND BORING OF JOISTS 7TYPICAL FRAMING @ ROOF OPENINGS 8TYPICAL GUARDRAIL POST INSTALLATION 9TYPICAL PLYWOOD NAILING 10LAG SCREW REQUIREMENTS 11HOLDOWN INSTALLATION 1/2" NOTES: 1. TABLE APPLIES FOR DOUGLAS FIR LARCH, SOUTHER PINE WOODS, AND REDWOOD (PER 1994 UBC SEC. 2337). 2. LAG SCREWS SHALL BE WRENCH TIGHTENED; HAMMERING OF LAG SCREWS IS NOT PERMITTED. 3. SOAP OR OTHER APPROVED LUBRICANTS SHALL BE USED ON THE THREADED PORTION OF THE LAG SCREW TO PREVENT DAMAGING THE SCREW AND FACILITATE INSERTION. 4. THE SHANK HOLE SHALL HAVE THE SAME DIAMETER AND DEPTH OF PENETRATION AS THE SHANK LENGTH AND DIAMETER. 5. THE LEAD HOLE SHALL HAVE THE SAME DEPTH AS THE THREADED PORTION OF THE LAG SCREW. TYPICAL SHEAR WALL OPENING DETAIL 1 8" DETAIL A A - CONT. STUDS/POST W/ B.N. & HOLDOWN PER PLAN (TYP.) CMSTC 16 OVER 4X BLK'G U.N.O. ON PLAN (TYP.) (SEE NOTE 4 & 5) 2X STUD PER PLAN SHEAR PANEL TYPE PER PLAN B.N. AT BLK'G & EDGES OF SHEAR WALL 2-2X TOP PL (SLOPED AT GABLE ROOF WHERE OCCURS) HEADER PER PLAN WINDOW SILL WHERE OCCURS NAILING/SCREWS /BOLT PER PLAN (2) ROWS 16d SINKER NAIL STAGG. PER SCHED. ABV. (TYP.) 2 ROWS 16d SINKER NAIL STAGG. PER SCHED. ABV. (TYP.) NOTES: 1. INSTALL HOLDOWN ON RETURN WALL AT CORNERS WHEN APPLICABLE. 2. USE FULL WIDTH BLK'G & WINDOW SILL FOR STRAP ON BOTH SIDES OF (2) SIDED SHEAR PANELS. 3. NAIL BOTH PLYWD. PANELS ON SAME MEMBER. 4. FOR SHEAR WALL WITH MULTIPLE OPENINGS, HORIZONTAL STRAP AT TOP AND BOTTOM OF THE OPENING SHOULD BE CONTINUED TO THE END OF WALL OR WHERE IT INTERSECTS THE VERTICAL EDGE OF ANOTHER OPENING. 5. IN CASE OF DOUBLE SIDED SHEAR WALL, USE HORIZONTAL STRAP ONLY AT ONE SIDE U.N.O. PANEL EDGE @ 6" O.C. @4" O.C. @ 3" O.C. @ 5" O.C. 1 2 3 4 PANEL TYPE NAIL SPACING EVGENY NA GOVITSY N AD D R E S S : 1 5 0 6 C L E M E N S E N A V E , S A N T A A N A , C A 9 2 7 0 5 OW N E R : N A N C Y C A L T A G I R O N E SHEAR WALL SCHEDULE TYPE SHEATHING MATERIAL PANEL NAILING PERIMETER FIELD BLKG. TO PLATE CONNECTION PLATE TO BLKG. CONNECTION ANCHOR BOLTS (U.N.O.) EMBED. DEPTH SHEAR, PLF (LRFD) SHEAR, PLF (ASD) SILL PLATE 1 15/32" PLYWOOD STRUCTURAL 1 10d @ 6" O.C. 10d @ 12" O.C. A35/ LTP4 @ 20" O.C. 20d NAILS @ 6" O.C. 5/8"∅ @ 48" O.C.9" 392 245 2x 2 15/32" PLYWOOD STRUCTURAL 1 10d @ 6" O.C. 10d @ 12" O.C. A35/ LTP4 @ 16" O.C. 20d NAILS @ 4" O.C. 5/8"∅ @ 32" O.C.9" 544 340 3x 3 15/32" PLYWOOD STRUCTURAL 1 10d @ 4" O.C. 10d @ 12" O.C. A35/ LTP4 @ 10" O.C. SDS 1/4"x6" @ 8" O.C. 5/8"∅ @24" O.C.9" 816 510 3x 4 15/32" PLYWOOD STRUCTURAL 1 10d @ 3" O.C. 10d @ 12" O.C. A35/ LTP4 @ 8" O.C. SDS 1/4"x6" @ 5" O.C. 5/8"∅ @ 24" O.C.9" 1064 665 3x 5 15/32" PLYWOOD STRUCTURAL 1 10d @ 2" O.C. 10d @ 12" O.C. A35/ LTP4 @ 6" O.C. SDS 1/4"x6" @ 4" O.C. 5/8"∅ @ 16" O.C.9" 1392 870 3x DRAWN: CHECKED: DATE: SCALE: JOB #: E.N. T.S. N.T.S. 24-24-456 SHEET: S4 07/26/24 1506 E Clemensen Ave & #212/12/2024 501 S. BRAND BLVD., SUITE 3 SAN FERNANDO, CA 91340 (323)486-4151 STENENGINEERING.COM SEAL DE T A I L S AD D R E S S : 1 5 0 6 C L E M E N S E N A V E , S A N T A A N A , C A 9 2 7 0 5 OW N E R : N A N C Y C A L T A G I R O N E EVGENY NA GOVITSY N DRAWN: CHECKED: DATE: SCALE: JOB #: B.O. E.N. N.T.S. 24-24-456 SHEET: S5 07/26/24 1 2 3 4 5 6 7 8 9 10 11 12 13 00 00 00NOT USED NOT USED NOT USED SHEAR WALL AT NEW FOOTING MIN 3" CLR. ALL AROUND 15" MIN 6 5 4 8" M I N 1 3 2 7 1 - SHEAR PANEL PER PLAN 2 - FINISHED GRADE 3 - 4" CONCRETE SLAB ON GRADE W/#4 @ 16" O.C. EACH WAY AT BOTTOM 4 - TYPICAL SUB-GRADE, SEE DETAIL 3/- 5 - #4 DOWELS @ 16" O.C. 6 - (2) #4 BAR TOP & BOTTOM 7 - WALL FOOTING, MINIMUM 15"x24" 8 - ANCHOR BOLT PER SHEAR WALL SCHEDULE, MIN @ 72" O.C. 9 - 2x STUD WALL 10 - 2x OR 3x P.T. SILL PLATE PER SHEAR WALL SCHEDULE 11 - BOUNDARY NAIL 12 - HOLDOWN ANCHORAGE PER TABLE ON S2 13 - HOLDOWN PER PLAN 8 9 1011 MIN 3" CLR. ALL AROUND 15" MIN 6 5 4 8" M I N 1 3 2 7 13 9 1011 24" 24" 24" 24"24 " M I N 24 " M I N 12 MIN 3" CLR. ALL AROUND 6 5 4 1 3 7 1 - SHEAR PANEL PER PLAN WHER OCCURS 2 - FINISHED GRADE 3 - 4" CONCRETE SLAB ON GRADE W/#4 @ 16" O.C. EACH WAY AT BOTTOM 4 - TYPICAL SUB-GRADE, SEE DETAIL 3/- 5 - #4 DOWELS @ 16" O.C. 6 - (2) #4 BAR TOP & BOTTOM 7 - WALL FOOTING, MINIMUM 15"x24" 8 - ANCHOR BOLT PER SHEAR WALL SCHEDULE, MIN @ 72" O.C. 9 - 2x STUD WALL 10 - P.T. SILL PLATE PER SHEAR WALL SCHEDULE 11 - BOUNDARY NAIL 12 - SSTB24 W/ MIN. EMBEDMENT 20" 13 - HOLDOWN PER PLAN 8 9 1011 24" 24" MIN 3" CLR. ALL AROUND 15" MIN 6 5 4 1 3 7 9 1011 24" 24" 13 12 15" MIN 24 " M I N 24 " M I N SHEAR WALL AT NEW FOOTING 5 4 2 3 1 1 - (N) SLAB ON GRADE PER PLAN 2 - 2" SAND LAYER 3 - 10 MIL. VAPOR BARRIER IN DIRECT CONTACT W/ SLAB 4 - 4" SUB-BASE 1 2" OR LARGER AGGREGATE 5 - UNDISTURBED SOIL TYPICAL SUB-GRADE L=30xDIA. OF REBAR , 2'-0" MIN. L L L TYP. L DOUBLE LAYER L L SINGLE LAYER REINFORCING AT FOOTING INTERSECTIONS 1 - A35 (BOTTOM A35 IS NOT REQUIRED WHERE COLUMN CAP IS USED PER PLAN) 2 - 2x SILL PLATE 3 - 3-8d TOE NAIL EACH SIDE NOTE: USE A34 IN LIEU OF A35 WHERE OCCURS AT 2x4 STUD WALLS 1 3 12 POST ON SILL PLATE 1 - (N) 2x STUD WALL 2 - 2x P.T. SILL PLATE 3 - (N) OR (E) SLAB ON GRADE (SEE NOTE) 4 - SIMPSON PINW-300 @ 16" O.C. TO BE INSTALLED IN ACCORDANCE WITH ICC ESR-2138 NOTE: (FOR INFORMATION NOT SHOWN FOR NEW SLAB ON GRADE AND SUB GRADE, SEE DETAIL 1/-) 1 23 PARTITION WALL AT SLAB ON GRADE 4 SHEAR TRANSFER 9 5 2 3 1 4 6 8 7 1 - RAFTER PER PLAN. NOTCH RAFTER TO PROVIDE FULL BEARING AT TOP PLATE ( 1 1 2" MAX. NOTCH) 2 - 2x SOLID BLOCKING 3 - BOUNDARY FASTENERS 4 - (3) 16d TOENAILS PER BLOCK 5 - A35 PER SHEAR WALL SCHEDULE, MIN AT 24" O.C. 6 - EAVE EXTENSION PER ARCH'L 7 - AS AN ALTERNATE, SIMPSON VPA2 MAY BE USED IN LIEU OF NOTCH PER 1 8 - 2x FASCIA W/ (3) 16d EACH RAFTER 9 - CEILING JOIST PER PLAN, USE MIN 5-16d NAILS EACH RAFTER TO JOIST, INSTALL FULL DEPTH 2x BLOCKING AT 48" O.C. 10 - ROOF SHEATHING PER PLAN 11 - SHEAR PANEL IF OCCURS 12 - CONNECT CEILING JOIST TO RAFTER W/ MIN. (5) 16d NAILS 10 11 12 PARTITION WALL FRAMING 1/2" CLR. 1/2" CLR. PERPENDICULAR 1 1 1 - PLYWOOD WHERE OCCURS 2 - 2x BLOCKING @ 24" O.C. W/ (2) 16d NAILS EACH END 3 - (E) OR (N) ROOF RAFTER OR CEILING JOIST OR FLOOR JOIST 4 - SIMPSON STC MAX @ 24" O.C. 5 - 1x OVER 2x PLATE 6 - (N) 2x STUDS PARTITION WALL 7 - 2x FLAT BLOCKING @ 24" O.C. W/ (2) 16d NAIL EACH END NOTE: CEILING SHEATHING TO BE CONNECTED TO WALL PLATE W/ DS CLIPS @ 16" O.C. & DO NOT CONNECT THE CEILING SHEATHING TO FRAMING WITHIN 16" OF WALL PLATE. 2 3 4 3 5 6 4 5 6 1/4" CLR. PARALLEL 13 7 6 4 BEAM TO HEADER AT POST DETAIL 1 2 3 4 5 1 - BEAM PER PLAN 2 - SIMPSON ECCQ FOR PSL BEAMS, OTHERWISE SIMPSON BC4 MAY BE USED 3 - 4x POST TO MATCH BEAM WIDTH 4 - INVERTED SIMPSON PC4Z/PC6Z 5 - HEADER PER PLAN * - CEILING JOISTS NOT SHOWN FOR CLARITY RIDGE BM TO HIP BM AT KING POST DETAIL 1 - RIDGE BEAM PER PLAN 2 - HIP BEAM PER PLAN 3 - SIMPSON PC4Z/EPC4Z AS REQ. 4 - 4x4 KING POST (U.N.O.) 5 - SIMPSON BC4/BC46 AS REQ. 6 - BEAM PER PLAN 7 - SIMPSON HHRC44 HANGER * - SHEATHING AND ROOF RAFTERS NOT SHOWN FOR CLARITY 1 2 3 4 5 7 6 INTERIOR SHEAR WALL AT ROOF RAFTERS A A 12 1 - LTP4 PER SHEAR WALL SCHEDULE 2 - SOLID 2x BLOCKING @ 48" O.C. W/ (3)16d TOENAILS INTO ROOF RAFTER 3 - BOUNDARY FASTENERS 4 - ROOF SHEATHING PER PLAN 5 - ROOF RAFTER PER PLAN 6 - SHEAR PANEL PER PLAN 7 - 2x4 @ 16" O.C. STUD WALL 3 SECTION A-A 1 5 3 4 6 7 2 4 5 6 1 - 2x RAFTER PER PLAN 2 - SOLID SINGLE 2x BLOCKING 3 - LTP4/A35 PER SHEAR WALL SHEDULE, FOR NON-SHEAR WALL @ 32" O.C. MIN 4 - BOUNDARY FASTENERS 5 - ROOF SHEATHING PER PLAN 6 - CEILING JOIST PER PLAN W/ (10) 6d NAILS JOIST TO JOIST 7 - BOUNDARY FASTENERS PER SHEAR WALL SCHEDULE 8 - SHEAR PANEL PER PLAN 9 - INSTALL SIMPSON MST72 STRAP PER MANUFACTURER AT EDGE POSTS 10 - USE 20d NAILS @ 6" O.C. @ SHEAR WALL 1 , USE SDS SCREW PER SHEAR WALL SCHEDULE AT WALLS 2 3 4 INTO BLOCKING INTERIOR SHEAR WALL 1 7 10 9 3 7 66 8 1 5 4 7 2 3 DRAG/STRAP CONNECTION DETAIL 1 - RAFTER PER PLAN 2 - EDGE NAILING PER PLAN INTO ROOF RAFTER 3 - DBL 2x TOP PLATE 4 - SKEWED AND SLOPED HU-TYPE HANGER 5 - STRAP PER PLAN 6 - ROOF SHEATHING PER PLAN 7 - STUD WALL W/ 2x STUDS @ 16" O.C. 8 - HIP BEAM PER PLAN 9 - HOLDOWN POST WHERE OCCURS 10- 2x ROOF RAFTER IN LINE W/ 2x STUD WALL NOTE: FOR INFORMATION NOT SHOWN SEE DETAIL 7/- & 10/- 10 2 3 8 1 2 6 9 7 4 5 1506 E Clemensen Ave & #212/12/2024 REVISIONS BY #2 MA I N H O U S E : 15 0 6 E C L E M E N S E N A V E SA N T A A N A , C A 9 2 7 0 5 1506 E Clemensen Ave & #212/12/2024 REVISIONS BY MA I N H O U S E : 15 0 6 E C L E M E N S E N A V E SA N T A A N A , C A 9 2 7 0 5 #2 GLEN SALCEDO 6860 CANBY AVE, STE 113 LOS ANGELES, CA 91335 818.578.5895 8/9/2024 1506 E Clemensen Ave & #212/12/2024 REVISIONS BY MA I N H O U S E : 15 0 6 E C L E M E N S E N A V E SA N T A A N A , C A 9 2 7 0 5 #2 1506 E Clemensen Ave & #212/12/2024 CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65 percent of the non-hazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. Exceptions: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan in conformance with Items 1 through 5. The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, reuse on the project or salvage for future use or sale. 2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or bulk mixed (single stream). 3. Identify diversion facilities where the construction and demolition waste material collected will be taken. 4. Identify construction methods employed to reduce the amount of construction and demolition waste generated. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. Notes: 1. Sample forms found in "A Guide to the California Green Building Standards Code (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section. 2. Mixed construction and demolition debris (C & D) processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building: 1. Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure. 2. Operation and maintenance instructions for the following: a. Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b. Roof and yard drainage, including gutters and downspouts. c. Space conditioning systems, including condensers and air filters. d. Landscape irrigation systems. e. Water reuse systems. 3. Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations. 4. Public transportation and/or carpool options available in the area. 5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range. 6. Information about water-conserving landscape and irrigation design and controllers which conserve water. 7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation. 8. Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc. 9. Information about state solar energy and incentive programs available. 10. A copy of all special inspections verifications required by the enforcing agency or this code. 11. Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures. 12. Information and/or drawings identifying the location of grab bar reinforcements. 4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive. Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of this section. DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3, and 4.303.4.4. Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-type Toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only allow one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.1.4.5 Pre-rinse spray valves. When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Sections 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7) and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations),Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A): Commercial prerinse spray values manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code. 4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code. TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL)1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL)MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. NOTES: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations, Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are available at: https://www.water.ca.gov/ ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar pervious material used to collect or channel drainage or runoff water. WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, management of storm water drainage and erosion controls shall comply with this section. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 3. Compliance with a lawfully enacted storm water management ordinance. Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or are part of a larger common plan of development which in total disturbs one acre or more of soil. (Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html) 4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales 2. Water collection and disposal systems 3. French drains 4. Water retention gardens 5. Other water measures which keep surface water away from buildings and aid in groundwater recharge. Exception: Additions and alterations not altering the drainage path. 4.106.4 Electric vehicle (EV) charging for new construction. New construction shall comply with Sections 4.106.4.1 or 4.106.4.2 to facilitate future installation and use of EV chargers. Electric vehicle supply equipment (EVSE) shall be installed in accordance with the California Electrical Code, Article 625. Exceptions: 1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions: 1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power. 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section 4.106.4, may adversely impact the construction cost of the project. 2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities. 4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code. 4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway termination location shall be permanently and visibly marked as "EV CAPABLE". CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application. Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section. Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. Exceptions: 1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable. 2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with Chapter 4 and Appendix A4, as applicable. 4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities. When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the requirements of Sections 4.106.4.2.1 and 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as a future EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details. 4.106.4.2.1Multifamily development projects with less than 20 dwelling units; and hotels and motels with less than 20 sleeping units or guest rooms. The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable. Ten (10) percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Exceptions: 1.When EV chargers (Level 2 EVSE) are installed in a number equal to or greater than the required number of EV capable spaces. 2.When EV chargers (Level 2 EVSE) are installed in a number less than the required number of EV capable spaces, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed. Notes: a.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use. 2.EV Ready. Twenty-five (25) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multifamily parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. Exception: Areas of parking facilities served by parking lifts. 4.106.4.2.2 Multifamily development projects with 20 or more dwelling units, hotels and motels with 20 or more sleeping units or guest rooms. The number of dwelling units, sleeping units or guest rooms shall be based on all buildings on a project site subject to this section. 1.EV Capable. Ten (10) percent of the total number of parking spaces on a building site, provided for all types of parking facilities, shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Electrical load calculations shall demonstrate that the electrical panel service capacity and electrical system, including any on-site distribution transformer(s), have sufficient capacity to simultaneously charge all EVs at all required EV spaces at a minimum of 40 amperes. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. Exception: When EV chargers (Level 2 EVSE) are installed in a number greater than five (5) percent of parking spaces required by Section 4.106.4.2.2, Item 3, the number of EV capable spaces required may be reduced by a number equal to the number of EV chargers installed over the five (5) percent required. Notes: a.Construction documents shall show locations of future EV spaces. b.There is no requirement for EV spaces to be constructed or available until receptacles for EV charging or EV chargers are installed for use. 2.EV Ready. Twenty-five (25) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. For multifamily parking facilities, no more than one receptacle is required per dwelling unit when more than one parking space is provided for use by a single dwelling unit. Exception: Areas of parking facilities served by parking lifts. 3.EV Chargers. Five (5) percent of the total number of parking spaces shall be equipped with Level 2 EVSE. Where common use parking is provided, at least one EV charger shall be located in the common use parking area and shall be available for use by all residents or guests. When low power Level 2 EV charging receptacles or Level 2 EVSE are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes, and installed EVSE shall have a capacity of not less than 30 amperes. ALMS shall not be used to reduce the minimum required electrical capacity to the required EV capable spaces. 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2, Item 3, shall comply with Section 4.106.4.2.2.1. Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. 4.106.4.2.2.1.1 Location. EVCS shall comply with at least one of the following options: 1.The charging space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. 2.The charging space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building. Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1 and Section 4.106.4.2.2.1.2, Item 3. 4.106.4.2.2.1.2 Electric vehicle charging stations (EVCS) dimensions. The charging spaces shall be designed to comply with the following: 1.The minimum length of each EV space shall be 18 feet (5486 mm). 2.The minimum width of each EV space shall be 9 feet (2743 mm). 3.One in every 25 charging spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EV space is 12 feet (3658 mm). a.Surface slope for this EV space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction. 4.106.4.2.2.1.3 Accessible EV spaces. In addition to the requirements in Sections 4.106.4.2.2.1.1 and 4.106.4.2.2.1.2, all EVSE, when installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. 4.106.4.2.3 EV space requirements. 1.Single EV space required. Install a listed raceway capable of accommodating a 208/240-volt dedicated branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or enclosure in close proximity to the location or the proposed location of the EV space. Construction documents shall identify the raceway termination point, receptacle or charger location, as applicable. The service panel and/ or subpanel shall have a 40-ampere minimum dedicated branch circuit, including branch circuit overcurrent protective device installed, or space(s) reserved to permit installation of a branch circuit overcurrent protective device. Exception: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space, at the time of original construction in accordance with the California Electrical Code. 2.Multiple EV spaces required. Construction documents shall indicate the raceway termination point and the location of installed or future EV spaces, receptacles or EV chargers. Construction documents shall also provide information on amperage of installed or future receptacles or EVSE, raceway method(s), wiring schematics and electrical load calculations. Plan design shall be based upon a 40-ampere minimum branch circuit. Required raceways and related components that are planned to be installed underground, enclosed, inaccessible or in concealed areas and spaces shall be installed at the time of original construction. SECTION 4.501 GENERAL 4.501.1 Scope The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section 93120.1. DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AY N/AY N/AY N/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 (January 2023)Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. DIVISION 4.2 ENERGY EFFICIENCY TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)]MAXIMUM FLOW RATE (gpm) Product Class 1 (≤1.00 Product Class 2 (> 5.0 ozf and ≤1.20 Product Class 3 (> 8.0 ozf)1.28 Exception: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the location or the proposed location of the EV space at the time of original construction in accordance with the California Electrical Code. 4.106.4.2.4 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE” in accordance with the California Electrical Code. 4.106.4.2.5 Electric Vehicle Ready Space Signage. Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multifamily buildings. When new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten (10) percent of the total number of parking spaces added or altered shall be electric vehicle charging spaces (EV spaces) capable of supporting future Level 2 EVSE. Notes: 1.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. X X OWNER OWNER X CONTRACTOR X CO N T R A C T O R X DE S I G N E R X X X X X X X X CO N T R A C T O R CO N T R A C T O R X X X X X CO N T R A C T O R CO N T R A C T O R X CO N T R A C T O R X X CO N T R A C T O R CO N T R A C T O R X X CO N T R A C T O R X CO N T R A C T O R X X CO N T R A C T O R A-1.1 X 1506 E Clemensen Ave & #212/12/2024 MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundredths of a gram (g O³/g ROC). Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 and 94701. MOISTURE CONTENT. The weight of the water in wood expressed in percentage of the weight of the oven-dry wood. PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging). Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a). REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. VOC. A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL. Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water, dust or debris which may enter the system. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with this section. 4.504.2.1 Adhesives, Sealants and Caulks. Adhesives, sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply: 1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and tricloroethylene), except for aerosol products, as specified in Subsection 2 below. 2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with section 94507. 4.504.2.2 Paints and Coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply. 4.504.2.3 Aerosol Paints and Coatings. Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation 8, Rule 49. 4.504.2.4 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following: 1. Manufacturer's product specification. 2. Field verification of on-site product containers. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes: 1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code. 4.505.2 CONCRETE SLAB FOUNDATIONS. Concrete slab foundations required to have a vapor retarder by California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by the California Residential Code, Chapter 5, shall also comply with this section. 4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the following: 1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency. 3. A slab design specified by a licensed design professional. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following: 1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece verified. 3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing. Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the following: 1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building. 2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control. a. Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of adjustment. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e., built-in) Notes: 1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination. 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods: 1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods. 2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods. 3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential Equipment Selection), or other equivalent design software or methods. Exception: Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD)50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS)500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed , at least 80% of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. hhtps://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 0121, CSA 0151, CSA 0153 and CSA 0325 standards. 5. Other methods acceptable to the enforcing agency. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE. Y N/AY N/AY N/AY N/A RESPON. PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 2 (January 2023)Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) X CO N T R A C T O R X X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X DE S I G N E R / C O N T R A C T O R X TI T L E 2 4 X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X CO N T R A C T O R X A-1.2 1506 E Clemensen Ave & #212/12/2024 Scale Project number Date Drawn by A-1.3 BMP's 37-23 04/2024 JENNY PARADA 613 S EASTBURY AVE, COVINA CA 91723 No.Description Date BEST MANAGEMENT PRACTICES jenny_parada@verizon.net CITY REQUIRED NOTE: TWO LAYERS OF GRAVEL BAGS OR FIBER ROLLS SHALL BE PROVIDED AROUND THE DOWNHILL BOUNDARIES OF THE SITE TO PREVENT EROSION AND RETAIN SOIL RUNOFF DURING CONSTRUCTION, NO SEDIMENT IS TO LEAVE THE JOB SITE. CRC 4.106.2 Owner Address NANCY CALTAGIRONE Main House: 1506 E CLEMENSEN AVE SANTA ANA, CA 92705 ADU: 1506 E CLEMENSEN AVE # 2 SANTA ANA, CA 92705 PHONE: 714-997-0313 1506 E Clemensen Ave & #212/12/2024 6 0' 6 0 ' 3 0 ' 8 0 ' 4 0 ' 7 A B A B MI L L O T EN G I N E E R I N G & C O N S U L T I N G 86 0 N . V I C E R O Y A V E . C O V I N A , C A 9 1 7 2 3 PH . ( 5 6 2 ) 5 7 2 - 3 5 0 7 E M A I L : S U R V E Y @ M I L L O T E N G I N E E R I N G . C O M DRAINAGE PLAN IN THE CITY OF SANTA ANA, COUNTY OF ORANGE, STATE OF CALIFORNIA. LOT 2 OF TRACT NO. 4977, AS PER MAP RECORDED IN BOOK 175 PAGES 28 TO 29 OF MISCELLANEOUS MAPS RECORDS IN THE COUNTY RECORDER OF SAID COUNTY DECLARATION OF ENGINEER OF RECORD I hereby declare that in my professional opinion, the design of the improvements as shown on these plans complies with the current Professional Engineering Standards and Practices. As the Engineer in responsible charge of the design of these improvements, I accept full responsibility for such design. I understand and acknowledge that the plan check of these plans by the City of SANTA ANA is a review for the limited purpose of ensuring that these plans comply with City procedures and other applicable codes and ordinances. The plan review process is not a determination of the technical adequacy of the design of the improvements. Such plan check does not therefore relieve me of my design responsibility. Signature ________ Date:_______ License No. ______ Exp. __________ BENCHMARK: UNDISTURBED AREA # 2 AD U : MA I N H O U S E : 1 5 0 6 E C L E M E N S E N A V E N U E S A N T A A N A , C A 9 2 7 0 5 1506 E Clemensen Ave & #212/12/2024 6 0' 3 0' 1 6 0 ' 3 0 ' 8 0 ' 4 0 ' 2 3 444 666 7 8 8 8 8 9 444 8 8 8 BOUNDARY & TOPOGRAPHIC SURVEY BENCHMARK: MI L L O T EN G I N E E R I N G & C O N S U L T I N G 86 0 N . V I C E R O Y A V E . C O V I N A , C A 9 1 7 2 3 PH O N E : ( 6 2 6 ) 8 0 4 - 5 9 9 1 | ( 5 6 2 ) 5 7 2 - 3 5 0 7 EM A I L : S U R V E Y @ M I L L O T E N G I N E E R I N G . C O M # 2 MA I N H O U S E : 15 0 6 E C L E M E N S E N AV E N U E ,S A NT A A N A , CA 9 2 7 0 5 AD U : 1506 E Clemensen Ave & #212/12/2024 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 3 jessielopez@santa-ana.org Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Jessie Lopez COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez David Penaloza Thai Viet Phan Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org INTERIM CITY MANAGER Tom Hatch CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall Also sent via email to:nancycmft@gmail.com January 8, 2024 Nancy Caltagirone 1506 E. Clemensen Avenue Santa Ana, CA. 92705 Subject: Address Assignment for a new Accessory Dwelling Unit located at 1506 East Clemensen Avenue and (APN: 390-184-02) in Santa Ana, CA Dear Nancy, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new Accessory Dwelling Unit located at 1506 East Clemensen Avenue and (APN: 390-184-02). Notice is hereby given that the following as signed address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted 1. 1506 E. Clemensen Avenue, Unit 2 (Address for new ADU) To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2709 or by email at ASevilla@santa-ana.org. Sincerely, Alexis Sevilla Planning Technician Reviewed by: Jerry Guevara, Senior Planner Exhibit A – Address Plan 1506 E Clemensen Ave & #212/12/2024 Address Letter for 1506 E. Clemensen Avenue Page 2 of 2 c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Mishele Richards, Orange County Fire Authority, GEO Files Coordinator Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager 1506 E Clemensen Ave & #212/12/2024 PROPERTY LINE 72' PROPERTY LINE 72' PR O P E R T Y L I N E 1 0 0 ' PR O P E R T Y L I N E 1 0 0 ' (E)DRIVEWAY (E)BACK YARD (E)FRONT YARD (E)DRAIN 2% SLOPE (E)DRAIN 2% SLOPE (E)DRAIN 2% SLOPE (E)DRAIN 2% SLOPE (E ) S I D E Y A R D (E)EASEMENT (E ) D R I V E W A Y (E)ELECTRIC METER (E ) W A T E R HE A T E R (E)GAS METER (E)GARAGE 440 SQ.FT. (E) SIDEWALK (E) PARKWAY CLEMENSEN AVE 25 ' - 2 " 22 ' - 2 " 17 ' - 7 " 35 ' - 1 " 32 ' - 9 " 32 ' - 2 " 35 ' - 1 " 5' - 4"19' - 1"8' - 4"6' - 4"27' - 5"5' - 7" 41' - 8"19' - 6"5' - 7" 36' - 4"4' - 0" 6' - 0 " 11' - 10"9' - 2" 12 ' - 9 " 8' - 0 " 25 ' - 0 " 6' - 0 " 13' - 7"11' - 0" (E)PORCH 50 SQ.FT. NON-SPRINKLERED 16 ' - 5 " (N)MINI SPLIT UNIT 28" H X 36" W X 15" D PROPERTY LINE 72' PROPERTY LINE 72' PR O P E R T Y L I N E 1 0 0 ' PR O P E R T Y L I N E 1 0 0 ' (E) SFD 2- STORY 2,680 SQ.FT. (E)DRIVEWAY (E)BACK YARD (E)FRONT YARD (E)PAVEMENT (E ) S I D E Y A R D (E)BACK YARD (E ) D R I V E W A Y (E)ELECTRIC METER (E ) W A T E R HE A T E R (E)GAS METER (E)GARAGE 440 SQ.FT. (E) SIDEWALK (E) PARKWAY CLEMENSEN AVE 25 ' - 2 " 22 ' - 2 " 17 ' - 7 " 32 ' - 9 " 32 ' - 2 " 35 ' - 1 " 5' - 4"19' - 1"8' - 4"6' - 4"27' - 5"5' - 7" 41' - 8"19' - 6"5' - 7" (E)PORCH 50 SQ.FT. NON-SPRINKLERED (E)DRAIN 2% SLOPE (E)DRAIN 2% SLOPE (E)DRAIN 2% SLOPE (E ) D R A I N 2% S L O PE (E)UNPERMITTED STRUCTURE TO BE DEMOLISHED Scale Project number Date Drawn by Owner Project Address Phone 1/8" = 1'-0" A-1 PLOT PLAN 37-23 NANCY CALTAGIRONE 01/2024 J.P. 1506 CLEMENSEN AVE SANTA ANA, CA 92705 613 S EASTBURY AVE, COVINA CA 91723 PROJECT INFORMATION Assessor's ID No.: 390-184-02 ite Address:1506 CLEMENSEN AVE SANTA ANA CA 92705 ct:N-TRACT: 4977 BLOCK: LOT: 2 Zone:R1 Lot Size: 7,199 SQ.FT. Type of Construction V-B Occupancy Group: R-3 Number of stories: 2-Story Height:<25' Fire Sprinklers: NO SCOPE OF WORK NEW DETACHED 1-STORY ACCESSORY DWELLING UNIT PROJECT SUMMARY -(E)First Floor 1,290 SQ.FT. -(E)Second Floor 874 SQ.FT. -(E)GARAGE 440 SQ.FT. -(E)PORCH 50 SQ.FT. -(N)DETACHED ADU 749 SQ.FT. TOTAL 3,403 SQ.FT. LOT COVERAGE: 1,290 (First Floor)+440 (Garage)+50(Porch)+749 (ADU)=2,529 SQ.FT. 2,529/7,199= 35.1 % PROJECT TEAM OWNER: NANCY CALTAGIRONE nancycmft@gmail.com 714-997-1313 CONTRACTOR: LASCANO CONSTRUCTION DRAFTING: JENNY PARADA miladrafting@gmail.com 626-347-9230 VICINITY MAP INDEXA-1 EXISTING AND PROPOSED SITE PLAN A-2 EXISTING FLOOR PLAN AND ROOF PLAN - Main HouseA-3 EXISTING EXTERIOR ELEVATIONS - Main HouseA-4 EXISTING EXTERIOR ELEVATIONS - Main House A-5 PROPOSED FLOOR PLAN - ADU A-6 EXTERIOR ELEVATIONS - ADU A-7 ROOF PLAN -ADU No. Description Date EXHIBIT A - ADDRESS PLAN ESC 1/8"=1'-0" NOTES: 1. THIS PROJECT SHALL COMPLY WITH TITLE 24 AND 2022 CALIFORNIA BUILDING CODE (CBC) CALIFORNIA MECHANICAL CODE (CMC) CALIFORNIA PLUMBING CODE (CPC) CALIFORNIA ELECTRICAL CODE (CEC) CALIFORNIA ENERGY CODE CALIFORNIA GREEN BUILDING CODE SANTA ANA MUNICIPAL CODE 714-997-0313 PROJECT LOCATION TRANSIT AVAILABLE @ 0.3 MILES NO PARKING REQUIRED PROJECT LOCATION EXISTING SITE PLAN ESC 1/8"=1'-0" (N) 1506 E. CLEMENSEN AVENUE UNIT 2 (E) 1506 E CLEMENSEN AVENUE 1506 E Clemensen Ave & #212/12/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 1506 E CLEMENSEN AVE SANTA ANA 92705 NEW DETACHED ACCESSORY DWELLING UNIT, 1-STORY 2,680 SQ.FT.749 SQ.FT.3,429 SQ.FT.2 0 JENNY PARADA 626-347-9230 4/20/2024 jenny_parada@verizon.net 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 323-486-4151 501 South Brand Boulevard, Suite 3, San Fernando, CA 91340 info@stenengineering.com www.stenengineering.com STRUCTURAL CALCULATIONS FOR ACCESSORY DWELLING UNIT SUBMITTAL PROJECT: 1506 Clemensen Ave, Santa Ana, CA 92705 JOB#: 24-24-456 DATE: 01.16.2023 BY: E.N.  Masonry  Wood  Others: gs more than 160 feet in Stru n for seismic force resisting s ES with the proposed corre ans or in the load path: (A f resolved is required before acce placement was checked. No dedware, shear wall nailing was ˜ Concrete Moment Frame ˜ ˜ Modulus of Elasticity* Seismic Moment Frames ˜ ˜ Others: ctural Height: Concrete mix m ystems. ponding correct ive actions nal report by the structural ob 06/30/26 07.26.2024 1506 E Clemensen Ave & #212/12/2024 2x4 3x4 2x6 10' Allowable span Size 24" 24" 24" 10' 10' 24" 16" 24" 24" - 16" 16" 2x4 2x6 7'-0" 24" 24" 24" This table is used to determine span for roof rafters, U.N.O. Based on California Residential Code 2022 , Table R802.4.1(2) This table is used to determine size, height and spacing of wood studs, U.N.O. Based on California Residential Code 2022 , Table R602.3(5) Maximum spacingOne floor only Stud size Stud height Stud height Non-bearing wallBearing walls Maximum spacing when supporting Roof and ceiling only One floor, roof and ceiling Two floors, roof and ceiling 14' 14' 20' 24" 24" 12" 24" 24" 18'-6" 2x10 2x12 24" 15'-11" 16" 12" Size Spacing A. Dead Load = 20 psf B. Live Load = 20 psf C. Total Deflection = L/240 16" 22'-7" 12" 26'-0"14'-7" 16" 19'-6" 12" 22'-6" D. Use Douglas Fir Larch #2 8'-7" 9'-10" 10'-4" 12'-7" Spacing Allowable span 24" 16" B. Live Load = 10 psf Spacing Allowable span C. Total Deflection = L/240 16" 23'-4"D. Use Douglas Fir Larch #2 2x10 24" 16" 12" 23'-3" exceeds 26' exceeds 26' 24" 16" 12" 9'-10" 11'-3" 12'-5" 24"exceeds 26' 12"exceeds 26' Size Spacing Allowable span Size 2x6 24" 15'-0" 2x12 12" 19'-6" 2x4 16" 17'-8" 2x8 24" 19'-1" 12" 25'-8" 16"exceeds 26'A. Dead Load = 5 psf This table is used to determine span for floor joists, U.N.O. Based on California Residential Code 2022 , Table R502.3.1(2) Size Spacing Allowable span Size Spacing Allowable span A. Dead Load = 20 psf 12" 10'-8" 12" 16'-5" B. Live Load = 40 psf 2x6 24" 7'-6" 2x10 24" 11'-8" 16" 9'-3" 16" 14'-3" C. Total Deflection = L/360 16" 11'-8" 16" 16'-6" D. Use Douglas Fir Larch #22x8 24" 9'-6" 2x12 24" 13'-6" 12" 13'-6"11 12" 19'-1" 2x8 24" 13'-0" 16" 16'-0" 12" 18'-5" This table is used to determine span for ceiling joists, U.N.O. Based on California Residential Code 2022 , Table R802.5.1(1) 1506 E Clemensen Ave & #212/12/2024 =15 =20 =5 =10 Floor Dead Load, psf =15 = 40 = 15 = 60 = 15 = W 1 at 0': = = = = = = = W 2 at 3.92': = = = = = = = Design criteria: Floor Live Load Deck Dead Load Deck Live Load L - length T.A. - tributary area WD = Ʃ(T.A. x DL) WL = Ʃ(T.A. x LL) Roof Dead Load, psf Roof Live Load, psf Ceiling Dead Load, psf Ceiling Live Load, psf (Uninhabitable attics without storage) T.A.FLOOR, ft 0 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 42 Ridge Beam 1 4x8 L, ft 3.92 T.A.ROOF, ft 2.83 T.A.ROOF, ft 4.79 T.A.CEILING, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 72 WL , lb 96 WL , lb 57 Wall Dead Load 1506 E Clemensen Ave & #212/12/2024 = = = = = = = = = = = = = = = = = = = = = = = = T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 154 WL , lb 206 Ridge Beam 2 4x8 L, ft 1.75 T.A.ROOF, ft 10.29 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 107 WL , lb 143 T.A.ROOF, ft 5.67 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 85 WL , lb 113 Hip Beam 1 4x8 L, ft 8 Valley Beam 1 4x8 L, ft 8 T.A.ROOF, ft 7.13 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 1506 E Clemensen Ave & #212/12/2024 = W 1 at 0': = = = = = = = W 2 at 6.58': = = = = = = = = = = = = = = = = = = = = = = = L, ft 14.58 T.A.FLOOR, ft 0 L, ft 14.58 T.A.ROOF, ft 7.54 T.A.CEILING, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 113 WL , lb 151 T.A.ROOF, ft 10.33 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 Hip Beam 2 4x8 L, ft 6.58 T.A.ROOF, ft 9.79 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 147 57 Hip Beam 3 4x10 Hip Beam 4 4x10 WL , lb 196 T.A.ROOF, ft 2.83 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 155 WL , lb 207 T.A.WALL, ft 0 WD , lb 42 WL , lb 1506 E Clemensen Ave & #212/12/2024 = = = = = = = = = = = = = = = = = = = = = = = = T.A.FLOOR, ft 0 L, ft 11.25 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 94 WL , lb 126 L, ft 11.25 Valley Beam 2 4x8 Ridge Beam 3 4x12 L, ft 13.58 T.A.ROOF, ft 8 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 119 WL , lb 158 T.A.ROOF, ft 6.29 T.A.CEILING, ft 0 Hip Beam 5 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 120 WL , lb 160 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 4x8 T.A.ROOF, ft 7.92 T.A.CEILING, ft 0 1506 E Clemensen Ave & #212/12/2024 = = = = = = = = = = = = = = = = = = = = 3.5x7 Parallam PSL 2.2E = = = = = = = = = = Beam 1 6x8 L, ft 11.33 T.A.ROOF, ft 0 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 0 WL , lb 0 P1D, lb 598 from Hip Beams 1 and Ridge Beam 1 at 5.67' P1L, lb 765 from Hip Beams 1 and Ridge Beam 1 at 5.67' Beam 2 6x8 L, ft 10.17 T.A.ROOF, ft 0 T.A.CEILING, ft 5.67 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 28 WL , lb 57 P1D, lb 350 from Beam 1 at 4.5' and 8.42' P1L, lb 383 from Beam 1 at 4.5' and 8.42' Beam 3 L, ft 10.42 T.A.ROOF, ft 0 T.A.CEILING, ft 0 T.A.FLOOR, ft 0 T.A.DECK, ft 0 P1L, lb 2272 from Hip Beams 5 and Ridge Beam 3 at 7.92' T.A.WALL, ft 0 WD , lb 0 WL , lb 0 P1D, lb 1827 from Hip Beams 5 and Ridge Beam 3 at 7.92' 1506 E Clemensen Ave & #212/12/2024 4x6 = = = = = = = = = = = = = = = = = = = = from Ridge Beam 2, Hip Beam 2, and Hip Beam 3 at 1.42' Header 1 L, ft 6 T.A.ROOF, ft 6.42 T.A.CEILING, ft 5.21 Header 2 4x8 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 1 WD , lb 137 WL , lb 181 L, ft 2.67 T.A.ROOF, ft 0 T.A.CEILING, ft 10.29 T.A.FLOOR, ft 0 T.A.DECK, ft 0 T.A.WALL, ft 0 WD , lb 51 WL , lb 103 P1D, lb 426 from Beam 2 at 0.42' P1L, lb 569 from Beam 2 at 0.42' P2D, lb 1328 from Ridge Beam 2, Hip Beam 2, and Hip Beam 3 at 1.42' P2L, lb 1686 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:RIDGE BEAM 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.0420->0.0720, Lr= 0.0570->0.0960 k/ft, Extent = 0.0 -->> 3.920 ft, Trib Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.602: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 2.046ft 68.22 psi= = 1,687.50psi 2x4Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 2x4 Maximum Shear Stress Ratio 0.303 : 1 3.634 ft= = 1,015.18psi Maximum Deflection 0 <180 560 Ratio =0 <120 Max Downward Transient Deflection 0.048 in 986Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.084 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 3.920 ft 1 0.361 0.182 0.90 1.500 1.001.00 1.00 0.11 438.4 1,215.0 0.10 162.01.00 29.51.00 1.00+D+Lr 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.920 ft 1 0.602 0.303 1.25 1.500 1.001.00 1.00 0.26 1,015.2 1,687.5 0.24 225.01.00 68.21.00 1.00+D+0.750Lr 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.920 ft 1 0.516 0.260 1.25 1.500 1.001.00 1.00 0.22 871.0 1,687.5 0.20 225.01.00 58.51.00 1.00+0.60D 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 3.920 ft 1 0.122 0.061 1.60 1.500 1.001.00 1.00 0.07 263.0 2,160.0 0.06 288.01.00 17.71.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:RIDGE BEAM 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.0839 1.989 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.241 0.286 Max Upward from Load Combinations 0.241 0.286 Max Upward from Load Cases 0.137 0.163 D Only 0.104 0.124 +D+Lr 0.241 0.286 +D+0.750Lr 0.207 0.246 +0.60D 0.062 0.074 Lr Only 0.137 0.163 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:RIDGE BEAM 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.1540, Lr = 0.2060 , Tributary Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.351: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 0.915ft 64.78 psi= = 1,687.50psi 2x4Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 2x4 Maximum Shear Stress Ratio 0.288 : 1 0.000 ft= = 592.37psi Maximum Deflection 0 <180 2054 Ratio =0 <120 Max Downward Transient Deflection 0.006 in 3601Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.011 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 1.830 ft 1 0.209 0.172 0.90 1.500 1.001.00 1.00 0.06 254.5 1,215.0 0.10 162.01.00 27.81.00 1.00+D+Lr 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 1.830 ft 1 0.351 0.288 1.25 1.500 1.001.00 1.00 0.15 592.4 1,687.5 0.23 225.01.00 64.81.00 1.00+D+0.750Lr 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 1.830 ft 1 0.301 0.247 1.25 1.500 1.001.00 1.00 0.13 507.9 1,687.5 0.19 225.01.00 55.51.00 1.00+0.60D 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 1.830 ft 1 0.071 0.058 1.60 1.500 1.001.00 1.00 0.04 152.7 2,160.0 0.06 288.01.00 16.71.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:RIDGE BEAM 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.0107 0.922 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.330 0.330 Max Upward from Load Combinations 0.330 0.330 Max Upward from Load Cases 0.188 0.188 D Only 0.142 0.142 +D+Lr 0.330 0.330 +D+0.750Lr 0.283 0.283 +0.60D 0.085 0.085 Lr Only 0.188 0.188 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.0->0.0850, Lr= 0.0->0.1130 k/ft, Extent = 0.0 -->> 8.0 ft, Trib Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.830: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 4.613ft 59.60 psi= = 1,687.50psi 4x4Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x4 Maximum Shear Stress Ratio 0.265 : 1 7.737 ft= = 1,399.95psi Maximum Deflection 0 <180 203 Ratio =0 <120 Max Downward Transient Deflection 0.262 in 366Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.472 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 8.0 ft 1 0.511 0.162 0.90 1.500 1.001.00 1.00 0.37 620.9 1,215.0 0.21 162.01.00 26.31.00 1.00+D+Lr 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.830 0.265 1.25 1.500 1.001.00 1.00 0.83 1,399.9 1,687.5 0.49 225.01.00 59.61.00 1.00+D+0.750Lr 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.714 0.228 1.25 1.500 1.001.00 1.00 0.72 1,205.2 1,687.5 0.42 225.01.00 51.31.00 1.00+0.60D 1.500 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.172 0.055 1.60 1.500 1.001.00 1.00 0.22 372.5 2,160.0 0.13 288.01.00 15.81.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.4716 4.175 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.275 0.539 Max Upward from Load Combinations 0.275 0.539 Max Upward from Load Cases 0.151 0.301 D Only 0.124 0.237 +D+Lr 0.275 0.539 +D+0.750Lr 0.237 0.463 +0.60D 0.074 0.142 Lr Only 0.151 0.301 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:VALLEY BEAM 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.1070->0.0, Lr= 0.1430->0.0 k/ft, Extent = 0.0 -->> 8.0 ft, Trib Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.492: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 3.387ft 44.81 psi= = 1,462.50psi 4x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x6 Maximum Shear Stress Ratio 0.199 : 1 0.000 ft= = 720.16psi Maximum Deflection 0 <180 621 Ratio =0 <120 Max Downward Transient Deflection 0.086 in 1122Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.155 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 8.0 ft 1 0.305 0.122 0.90 1.300 1.001.00 1.00 0.47 320.9 1,053.0 0.25 162.01.00 19.81.00 1.00+D+Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.492 0.199 1.25 1.300 1.001.00 1.00 1.06 720.2 1,462.5 0.58 225.01.00 44.81.00 1.00+D+0.750Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.424 0.171 1.25 1.300 1.001.00 1.00 0.91 620.4 1,462.5 0.49 225.01.00 38.61.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 8.0 ft 1 0.103 0.041 1.60 1.300 1.001.00 1.00 0.28 192.6 1,872.0 0.15 288.01.00 11.91.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:VALLEY BEAM 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.1545 3.854 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.683 0.350 Max Upward from Load Combinations 0.683 0.350 Max Upward from Load Cases 0.381 0.191 D Only 0.302 0.159 +D+Lr 0.683 0.350 +D+0.750Lr 0.588 0.302 +0.60D 0.181 0.096 Lr Only 0.381 0.191 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.571: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 3.002ft 56.11 psi= = 1,462.50psi 4x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x6 Maximum Shear Stress Ratio 0.249 : 1 0.000 ft= = 835.39psi Maximum Deflection 0 <180 641 Ratio =0 <120 Max Downward Transient Deflection 0.069 in 1141Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.123 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 6.580 ft 1 0.348 0.151 0.90 1.300 1.001.00 1.00 0.54 366.0 1,053.0 0.31 162.01.00 24.51.00 1.00+D+Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.580 ft 1 0.571 0.249 1.25 1.300 1.001.00 1.00 1.23 835.4 1,462.5 0.72 225.01.00 56.11.00 1.00+D+0.750Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.580 ft 1 0.491 0.214 1.25 1.300 1.001.00 1.00 1.06 718.0 1,462.5 0.62 225.01.00 48.21.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.580 ft 1 0.117 0.051 1.60 1.300 1.001.00 1.00 0.32 219.6 1,872.0 0.19 288.01.00 14.71.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.1231 3.242 0.0000 0.000 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.875 0.607 Max Upward from Load Combinations 0.875 0.607 Max Upward from Load Cases 0.492 0.340 D Only 0.382 0.267 +D+Lr 0.875 0.607 +D+0.750Lr 0.752 0.522 +0.60D 0.229 0.160 Lr Only 0.492 0.340 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 3 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.1550->0.0, Lr= 0.2070->0.0 k/ft, Extent = 0.0 -->> 14.580 ft, Trib Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.912: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 6.173ft 71.47 psi= = 1,350.00psi 4x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x10 Maximum Shear Stress Ratio 0.318 : 1 0.000 ft= = 1,230.64psi Maximum Deflection 0 <180 335 Ratio =0 <120 Max Downward Transient Deflection 0.287 in 609Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.522 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 14.527 ft 1 0.568 0.196 0.90 1.200 1.001.00 1.00 2.30 552.0 972.0 0.69 162.01.00 31.81.00 1.00Length = 0.05321 ft 1 0.006 0.196 0.90 1.200 1.001.00 1.00 0.02 5.5 972.0 0.42 162.01.00 31.81.00 1.00+D+Lr 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 14.527 ft 1 0.912 0.318 1.25 1.200 1.001.00 1.00 5.12 1,230.6 1,350.0 1.54 225.01.00 71.51.00 1.00Length = 0.05321 ft 1 0.009 0.318 1.25 1.200 1.001.00 1.00 0.05 11.9 1,350.0 0.92 225.01.00 71.51.00 1.00+D+0.750Lr 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 14.527 ft 1 0.786 0.274 1.25 1.200 1.001.00 1.00 4.41 1,061.0 1,350.0 1.33 225.01.00 61.61.00 1.00Length = 0.05321 ft 1 0.008 0.274 1.25 1.200 1.001.00 1.00 0.04 10.3 1,350.0 0.79 225.01.00 61.61.00 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 3 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+0.60D 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 14.527 ft 1 0.192 0.066 1.60 1.200 1.001.00 1.00 1.38 331.2 1,728.0 0.41 288.01.00 19.11.00 1.00Length = 0.05321 ft 1 0.002 0.066 1.60 1.200 1.001.00 1.00 0.01 3.3 1,728.0 0.25 288.01.00 19.11.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.5217 7.024 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.810 0.931 Max Upward from Load Combinations 1.810 0.931 Max Upward from Load Cases 1.006 0.503 D Only 0.804 0.428 +D+Lr 1.810 0.931 +D+0.750Lr 1.559 0.805 +0.60D 0.483 0.257 Lr Only 1.006 0.503 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 4 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.0->0.1130, Lr= 0.0->0.1510 k/ft, Extent = 0.0 -->> 14.580 ft, Trib Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.674: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 8.354ft 52.69 psi= = 1,350.00psi 4x10Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x10 Maximum Shear Stress Ratio 0.234 : 1 13.835 ft= = 909.36psi Maximum Deflection 0 <180 453 Ratio =0 <120 Max Downward Transient Deflection 0.209 in 835Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.385 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 14.527 ft 1 0.426 0.147 0.90 1.200 1.001.00 1.00 1.72 414.3 972.0 0.51 162.01.00 23.81.00 1.00Length = 0.05321 ft 1 0.008 0.147 0.90 1.200 1.001.00 1.00 0.03 7.6 972.0 0.51 162.01.00 23.81.00 1.00+D+Lr 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 14.527 ft 1 0.674 0.234 1.25 1.200 1.001.00 1.00 3.78 909.4 1,350.0 1.14 225.01.00 52.71.00 1.00Length = 0.05321 ft 1 0.013 0.234 1.25 1.200 1.001.00 1.00 0.07 17.0 1,350.0 1.14 225.01.00 52.71.00 1.00+D+0.750Lr 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 14.527 ft 1 0.582 0.202 1.25 1.200 1.001.00 1.00 3.27 785.6 1,350.0 0.98 225.01.00 45.51.00 1.00Length = 0.05321 ft 1 0.011 0.202 1.25 1.200 1.001.00 1.00 0.06 14.6 1,350.0 0.98 225.01.00 45.51.00 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 4 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu 1.00+0.60D 1.200 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 14.527 ft 1 0.144 0.050 1.60 1.200 1.001.00 1.00 1.03 248.6 1,728.0 0.31 288.01.00 14.31.00 1.00Length = 0.05321 ft 1 0.003 0.050 1.60 1.200 1.001.00 1.00 0.02 4.6 1,728.0 0.31 288.01.00 14.31.00 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.3854 7.609 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.693 1.334 Max Upward from Load Combinations 0.693 1.334 Max Upward from Load Cases 0.367 0.734 D Only 0.326 0.600 +D+Lr 0.693 1.334 +D+0.750Lr 0.601 1.151 +0.60D 0.195 0.360 Lr Only 0.367 0.734 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:VALLEY BEAM 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.0590->0.0, Lr= 0.0790->0.0 k/ft, Extent = 0.0 -->> 11.250 ft, Trib Width = 1.0 ft, (ROOF RAFTERS) Uniform Load : D = 0.0350, Lr = 0.0470 , Tributary Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.666: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 5.214ft 52.14 psi= = 1,462.50psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.232 : 1 0.000 ft= = 974.16psi Maximum Deflection 0 <180 422 Ratio =0 <120 Max Downward Transient Deflection 0.176 in 765Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.319 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 11.250 ft 1 0.414 0.143 0.90 1.300 1.001.00 1.00 1.11 435.5 1,053.0 0.39 162.01.00 23.21.00 1.00+D+Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.250 ft 1 0.666 0.232 1.25 1.300 1.001.00 1.00 2.49 974.2 1,462.5 0.88 225.01.00 52.11.00 1.00+D+0.750Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.250 ft 1 0.574 0.200 1.25 1.300 1.001.00 1.00 2.15 839.5 1,462.5 0.76 225.01.00 44.91.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.250 ft 1 0.140 0.048 1.60 1.300 1.001.00 1.00 0.67 261.3 1,872.0 0.24 288.01.00 13.91.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:VALLEY BEAM 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.3192 5.543 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.010 0.751 Max Upward from Load Combinations 1.010 0.751 Max Upward from Load Cases 0.561 0.413 D Only 0.449 0.338 +D+Lr 1.010 0.751 +D+0.750Lr 0.870 0.648 +0.60D 0.269 0.203 Lr Only 0.561 0.413 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 5 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Load for Span Number 1 Varying Uniform Load : D= 0.0->0.1190, Lr= 0.0->0.1580 k/ft, Extent = 0.0 -->> 11.250 ft, Trib Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.625: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 6.446ft 53.87 psi= = 1,462.50psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.239 : 1 10.675 ft= = 913.43psi Maximum Deflection 0 <180 459 Ratio =0 <120 Max Downward Transient Deflection 0.161 in 837Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.294 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 11.250 ft 1 0.391 0.149 0.90 1.300 1.001.00 1.00 1.05 411.4 1,053.0 0.41 162.01.00 24.11.00 1.00+D+Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.250 ft 1 0.625 0.239 1.25 1.300 1.001.00 1.00 2.33 913.4 1,462.5 0.91 225.01.00 53.91.00 1.00+D+0.750Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.250 ft 1 0.539 0.206 1.25 1.300 1.001.00 1.00 2.01 787.9 1,462.5 0.79 225.01.00 46.41.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.250 ft 1 0.132 0.050 1.60 1.300 1.001.00 1.00 0.63 246.9 1,872.0 0.24 288.01.00 14.41.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HIP BEAM 5 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.2939 5.871 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.550 1.070 Max Upward from Load Combinations 0.550 1.070 Max Upward from Load Cases 0.296 0.593 D Only 0.254 0.477 +D+Lr 0.550 1.070 +D+0.750Lr 0.476 0.922 +0.60D 0.152 0.286 Lr Only 0.296 0.593 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:RIDGE BEAM 3 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.120, Lr = 0.160 , Tributary Width = 1.0 ft, (ROOF RAFTERS) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.874: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 6.790ft 64.83 psi= = 1,237.50psi 4x12Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x12 Maximum Shear Stress Ratio 0.288 : 1 0.000 ft= = 1,081.10psi Maximum Deflection 0 <180 487 Ratio =0 <120 Max Downward Transient Deflection 0.185 in 879Ratio = >=180 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.334 in Ratio = >=120 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 13.580 ft 1 0.541 0.178 0.90 1.100 1.001.00 1.00 2.96 481.6 891.0 0.76 162.01.00 28.91.00 1.00+D+Lr 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 13.580 ft 1 0.874 0.288 1.25 1.100 1.001.00 1.00 6.65 1,081.1 1,237.5 1.70 225.01.00 64.81.00 1.00+D+0.750Lr 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 13.580 ft 1 0.753 0.248 1.25 1.100 1.001.00 1.00 5.73 931.2 1,237.5 1.47 225.01.00 55.81.00 1.00+0.60D 1.100 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 13.580 ft 1 0.182 0.060 1.60 1.100 1.001.00 1.00 1.78 289.0 1,584.0 0.45 288.01.00 17.31.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:RIDGE BEAM 3 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.3342 6.840 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.959 1.959 Max Upward from Load Combinations 1.959 1.959 Max Upward from Load Cases 1.086 1.086 D Only 0.873 0.873 +D+Lr 1.959 1.959 +D+0.750Lr 1.688 1.688 +0.60D 0.524 0.524 Lr Only 1.086 1.086 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:BEAM 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Point Load : D = 0.5980, Lr = 0.7650 k @ 5.670 ft, (HIP BEAMS 1 + RIDGE BEAM 1) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.828: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 5.665ft 26.44 psi= = 1,125.00psi 6x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 6x8 Maximum Shear Stress Ratio 0.118 : 1 10.710 ft= = 931.08psi Maximum Deflection 0 <240 560 Ratio =0 <180 Max Downward Transient Deflection 0.130 in 1044Ratio = >=240 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.243 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 11.330 ft 1 0.527 0.077 0.90 1.000 1.001.00 1.00 1.84 427.2 810.0 0.34 162.01.00 12.51.00 1.00+D+Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.330 ft 1 0.828 0.118 1.25 1.000 1.001.00 1.00 4.00 931.1 1,125.0 0.73 225.01.00 26.41.00 1.00+D+0.750Lr 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.330 ft 1 0.716 0.102 1.25 1.000 1.001.00 1.00 3.46 805.1 1,125.0 0.63 225.01.00 23.01.00 1.00+0.60D 1.000 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 11.330 ft 1 0.178 0.026 1.60 1.000 1.001.00 1.00 1.10 256.3 1,440.0 0.21 288.01.00 7.51.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:BEAM 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.2427 5.706 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.732 0.733 Max Upward from Load Combinations 0.732 0.733 Max Upward from Load Cases 0.382 0.383 D Only 0.349 0.350 +D+Lr 0.732 0.733 +D+0.750Lr 0.636 0.637 +0.60D 0.210 0.210 Lr Only 0.382 0.383 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:BEAM 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0280, Lr = 0.0570 , Tributary Width = 1.0 ft, (CEILING JOISTS) Point Load : D = 0.350, Lr = 0.3830 k @ 4.50 ft, (BEAM 1) Point Load : D = 0.350, Lr = 0.3830 k @ 8.420 ft, (BEAM 1) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.952: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 4.528ft 79.07 psi= = 1,462.50psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.351 : 1 9.576 ft= = 1,392.10psi Maximum Deflection 0 <240 343 Ratio =0 <180 Max Downward Transient Deflection 0.199 in 614Ratio = >=240 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.355 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 10.170 ft 1 0.585 0.217 0.90 1.300 1.001.00 1.00 1.57 616.2 1,053.0 0.60 162.01.00 35.21.00 1.00+D+Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.170 ft 1 0.952 0.351 1.25 1.300 1.001.00 1.00 3.56 1,392.1 1,462.5 1.34 225.01.00 79.11.00 1.00+D+0.750Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.170 ft 1 0.819 0.303 1.25 1.300 1.001.00 1.00 3.06 1,198.1 1,462.5 1.15 225.01.00 68.11.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.170 ft 1 0.197 0.073 1.60 1.300 1.001.00 1.00 0.94 369.7 1,872.0 0.36 288.01.00 21.11.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:BEAM 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.3550 5.159 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.995 1.391 Max Upward from Load Combinations 0.995 1.391 Max Upward from Load Cases 0.569 0.776 D Only 0.426 0.615 +D+Lr 0.995 1.391 +D+0.750Lr 0.853 1.197 +0.60D 0.255 0.369 Lr Only 0.569 0.776 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:BEAM 3 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design iLevel Truss Joist Parallam PSL 2.2E 2900 2900 2900 750 2200 1118.19 290 2025 45.07 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Point Load : D = 1.827, Lr = 2.272 k @ 7.920 ft, (HIP BEAMS 5) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.857: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 7.910ft 192.93 psi= = 3,848.50psi 3.5x7.0Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 362.50 psi== Section used for this span 3.5x7.0 Maximum Shear Stress Ratio 0.532 : 1 9.850 ft= = 3,297.83psi Maximum Deflection 0 <240 238 Ratio =0 <180 Max Downward Transient Deflection 0.286 in 437Ratio = >=240 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.524 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 10.420 ft 1 0.537 0.334 0.90 1.062 1.001.00 1.00 3.54 1,487.6 2,770.9 1.42 261.01.00 87.21.00 1.00+D+Lr 1.062 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.420 ft 1 0.857 0.532 1.25 1.062 1.001.00 1.00 7.86 3,297.8 3,848.5 3.15 362.51.00 192.91.00 1.00+D+0.750Lr 1.062 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.420 ft 1 0.739 0.459 1.25 1.062 1.001.00 1.00 6.78 2,845.3 3,848.5 2.72 362.51.00 166.51.00 1.00+0.60D 1.062 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 10.420 ft 1 0.181 0.113 1.60 1.062 1.001.00 1.00 2.13 892.6 4,926.1 0.85 464.01.00 52.31.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:BEAM 3 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.5243 5.856 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 1.023 3.156 Max Upward from Load Combinations 1.023 3.156 Max Upward from Load Cases 0.545 1.727 D Only 0.478 1.429 +D+Lr 1.023 3.156 +D+0.750Lr 0.887 2.724 +0.60D 0.287 0.857 Lr Only 0.545 1.727 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HEADER 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.1370, Lr = 0.1810 , Tributary Width = 1.0 ft, (ROOF RAFTERS + CEILING JOISTS + WALL) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.674: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 3.000ft 64.32 psi= = 1,462.50psi 4x6Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x6 Maximum Shear Stress Ratio 0.286 : 1 0.000 ft= = 985.92psi Maximum Deflection 0 <240 591 Ratio =0 <180 Max Downward Transient Deflection 0.068 in 1053Ratio = >=240 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.122 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 6.0 ft 1 0.410 0.174 0.90 1.300 1.001.00 1.00 0.64 432.0 1,053.0 0.36 162.01.00 28.21.00 1.00+D+Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.674 0.286 1.25 1.300 1.001.00 1.00 1.45 985.9 1,462.5 0.83 225.01.00 64.31.00 1.00+D+0.750Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.579 0.246 1.25 1.300 1.001.00 1.00 1.25 847.4 1,462.5 0.71 225.01.00 55.31.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 6.0 ft 1 0.138 0.059 1.60 1.300 1.001.00 1.00 0.38 259.2 1,872.0 0.22 288.01.00 16.91.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HEADER 1 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.1217 3.022 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 0.967 0.967 Max Upward from Load Combinations 0.967 0.967 Max Upward from Load Cases 0.543 0.543 D Only 0.424 0.424 +D+Lr 0.967 0.967 +D+0.750Lr 0.831 0.831 +0.60D 0.254 0.254 Lr Only 0.543 0.543 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HEADER 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: CODE REFERENCES Calculations per NDS 2018, IBC 2021, ASCE 7-16 Load Combination Set : ASCE 7-16 Material Properties Beam Bracing :Beam is Fully Braced against lateral-torsional buckling Allowable Stress Design Douglas Fir-Larch No.2 900.0 900.0 1,350.0 625.0 1,600.0 580.0 180.0 575.0 31.210 Analysis Method : Eminbend - xx ksi Wood Species : Wood Grade : Fb + psi psi Fv psi Fb - Ft psi Fc - Prll psi psiFc - Perp E : Modulus of Elasticity Ebend- xx ksi Density pcf Load Combination :ASCE 7-16 .Applied Loads Service loads entered. Load Factors will be applied for calculations. Beam self weight calculated and added to loading Uniform Load : D = 0.0510, Lr = 0.1030 , Tributary Width = 1.0 ft, (CEILING JOISTS) Point Load : D = 0.4260, Lr = 0.5690 k @ 0.420 ft, (BEAM 2) Point Load : D = 1.328, Lr = 1.686 k @ 1.420 ft, (RIDGE BEAM 2 + HIP BEAM 2 + HIP BEAM 3) .DESIGN SUMMARY Design OK Maximum Bending Stress Ratio 0.625: 1 Load Combination +D+Lr Span # where maximum occurs Span # 1 Location of maximum on span 1.423ft 110.90 psi= = 1,462.50psi 4x8Section used for this span Span # where maximum occurs Location of maximum on span Span # 1= Load Combination +D+Lr = = = 225.00 psi== Section used for this span 4x8 Maximum Shear Stress Ratio 0.493 : 1 2.066 ft= = 914.28psi Maximum Deflection 0 <240 2224 Ratio =0 <180 Max Downward Transient Deflection 0.008 in 3923Ratio = >=240 Max Upward Transient Deflection 0 in Ratio = Max Downward Total Deflection 0.014 in Ratio = >=180 Max Upward Total Deflection 0 in fb: Actual F'b fv: Actual F'v Span: 1 : Lr Only n/a Span: 1 : +D+Lr n/a .Maximum Forces & Stresses for Load Combinations Span # Moment ValuesLoad Combination C iCLx CCCMCF rt Shear ValuesMax Stress Ratios M CDV fbM fvF'b V F'vSegment Length Cfu D Only 0.0 0.00 0.00.0 1.00Length = 2.670 ft 1 0.377 0.297 0.90 1.300 1.001.00 1.00 1.01 397.1 1,053.0 0.81 162.01.00 48.21.00 1.00+D+Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 2.670 ft 1 0.625 0.493 1.25 1.300 1.001.00 1.00 2.34 914.3 1,462.5 1.88 225.01.00 110.91.00 1.00+D+0.750Lr 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 2.670 ft 1 0.537 0.423 1.25 1.300 1.001.00 1.00 2.01 785.0 1,462.5 1.61 225.01.00 95.21.00 1.00+0.60D 1.300 1.001.00 1.00 0.0 0.00 0.01.00 0.01.00 1.00Length = 2.670 ft 1 0.127 0.100 1.60 1.300 1.001.00 1.00 0.61 238.3 1,872.0 0.49 288.01.00 28.91.00 . 1506 E Clemensen Ave & #212/12/2024 Wood Beam LIC# : KW-06013476, Build:20.23.07.20 The Stane Corporation (c) ENERCALC INC 1983-2023 DESCRIPTION:HEADER 2 Project File: 3 - CLEMENSEN ENERCALC.ec6 Project Title: Engineer: Project ID: Project Descr: Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections +D+Lr 1 0.0144 1.345 0.0000 0.000 . Load Combination Support 1 Support 2 Vertical Reactions Support notation : Far left is #1 Values in KIPS Max Upward from all Load Conditions 2.462 1.972 Max Upward from Load Combinations 2.462 1.972 Max Upward from Load Cases 1.406 1.124 D Only 1.056 0.849 +D+Lr 2.462 1.972 +D+0.750Lr 2.111 1.691 +0.60D 0.634 0.509 Lr Only 1.406 1.124 1506 E Clemensen Ave & #212/12/2024 ASCE Hazards Report Address: 1506 Clemensen Ave Santa Ana, California 92705 Standard:ASCE/SEI 7-16 Latitude:33.773567 Risk Category:II Longitude:-117.847948 Soil Class:D - Default (see Section 11.4.3) Elevation:194.68435775220897 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Thu Jul 25 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Thu Jul 25 2024 1506 E Clemensen Ave & #212/12/2024 SS : 1.332 S1 : 0.474 F a : 1.2 F v : N/A SMS : 1.599 SM1 : N/A SDS : 1.066 SD1 : N/A T L : 8 PGA : 0.558 PGA M : 0.67 F PGA : 1.2 Ie : 1 C v : 1.366 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Thu Jul 25 2024 Page 2 of 3https://ascehazardtool.org/Thu Jul 25 2024 1506 E Clemensen Ave & #212/12/2024 1.066 Design Spectral Response Accelaration Parameter (see ASCE 7 Hazards Report) R=6.5 Response Modification Factor (see ASCE 7-22 Table 12.2-1) Ie=1 Importance Factor (see ASCE 7-22 Table 1.5-2) 0.1640 Seismic Response Coefficient = SDS/(R x Ie) 1.3 20 10 15 883 Effective seismic weight at roof level: Wall height (ft) = 8 Wroof = DLroof + ½ DLPW 2nd + ½DLEW 2nd 123 Wroof (lb)= 29455 Lt - total length of SW in given grid line Ls - shortest wall in given grid line V = T.A. - tributary area V (lb) = 6280 h - wall height V - shear force in given grid line v - shear force per linear ft of shear wall vu = V/footprint area Uplift = v*h vu (psf) = 7.11 LRFD Selfweight = L*h*wall weight vu (psf) = 4.98 ASD (LRFD x 0.7) vcap - shear wall capacity ARF - Aspect Ratio Factor = 1.25 - 0.125*h/L s vred. - reduced shear wall capacity = vcap*ARF Aspect Ratio = h/LS HDU2 3075 HDU4 4565 HDU5 5645 HDU8 7870 HDU11 11175 HDU14 14445 Maximum shear per linear foot, lb (ASD) 1 Base shear: Unit story shear (per 1 sf) 1.3 x Cs x Wroof 245 2306 3424 4234 5903 Shear wall Type (see plans for details) Model No. Exterior wall perimeter (ft) = Allowable tension load (lb) Exterior wall (EW) DL (psf) = Footprint area (sf) = Allowable tension load (lb), reduced for 25% per LARR# 25720 Lateral analysis Cs = Roof & ceiling DL (psf) = Partition wall(PW) DL (psf) = SDS= Redundancy factor = 4 665 5 870 8381 10834 2 340 3 510 323-486-4151 info@stenengineering.com 501 South Brand Boulevard, Suite 3, San Fernando, CA 91340 www.stenengineering.com 1506 E Clemensen Ave & #212/12/2024 Line 1: Lt=6.5 (ft)Ls=3 (ft) T.A.= 154 (sq ft) h= 8 (ft) V = 767 (lbs) Uplift 944 (lbs) ν =118 (lb/ft) Selfweight = 180 (lbs) ARF= 0.92 Net Uplift (ASD)= 836 (lbs) Aspect Ratio= 2.67 O.K. 1 vred.=225 (lb/ft) Line 2: Lt=13 (ft)Ls=5 (ft) T.A.= 404 (sq ft) h= 8 (ft) V = 2011 (lbs) Uplift 1238 (lbs) ν =155 (lb/ft) Selfweight = 300 (lbs) Net Uplift (ASD)= 1058 (lbs) 1 Line 3: Lt=17 (ft)Ls=17 (ft) T.A.= 325 (sq ft) h= 8 (ft) V = 1618 (lbs) Uplift 761 (lbs) ν =95 (lb/ft) Selfweight = 1020 (lbs) Net Uplift (ASD)= 149 (lbs) 1 Line A: Lt=8 (ft)Ls=4 (ft) T.A.= 119 (sq ft) h= 8 (ft) V = 592 (lbs) Uplift 592 (lbs) ν =74 (lb/ft) Selfweight = 240 (lbs) Net Uplift (ASD)= 448 (lbs) 1 Line B: Lt=6.5 (ft)Ls=3 (ft) T.A.= 81 (sq ft) h= 8 (ft) V = 403 (lbs) Uplift 496 (lbs) ν =62 (lb/ft) Selfweight = 180 (lbs) ARF= 0.92 Net Uplift (ASD)= 388 (lbs) Aspect Ratio= 2.67 O.K. 1 vred.=225 (lb/ft) (ASD) Use Shear Wall Type Use MST72 or HDU2 (ASD) Use Shear Wall Type Use MST72 or HDU2 (ASD) Use Shear Wall Type Use MST72 or HDU2 (ASD) Use Shear Wall Type Use MST72 or HDU2 (ASD) Use Shear Wall Type Use MST72 or HDU2 323-486-4151 info@stenengineering.com 501 South Brand Boulevard, Suite 3, San Fernando, CA 91340 www.stenengineering.com 1506 E Clemensen Ave & #212/12/2024 Line C: Lt=9.5 (ft)Ls=9.5 (ft) T.A.= 74 (sq ft) h= 8 (ft) V = 368 (lbs) Uplift 310 (lbs) ν =39 (lb/ft) Selfweight = 570 (lbs) Net Uplift (ASD)= 32 (lbs) 1 Line D: Lt=11.5 (ft)Ls=11.5 (ft) T.A.= 386 (sq ft) h= 8 (ft) V = 1922 (lbs) Uplift 1337 (lbs) ν =167 (lb/ft) Selfweight = 690 (lbs) Net Uplift (ASD)= 923 (lbs) 1 Line E: Lt=31 (ft)Ls=9 (ft) T.A.= 223 (sq ft) h= 8 (ft) V = 1110 (lbs) Uplift 286 (lbs) ν =36 (lb/ft) Selfweight = 540 (lbs) Net Uplift (ASD)= 38 (lbs) 1Use Shear Wall Type Use MST72 or HDU2 (ASD) Use Shear Wall Type Use MST72 or HDU2 (ASD) Use Shear Wall Type Use MST72 or HDU2 (ASD) 323-486-4151 info@stenengineering.com 501 South Brand Boulevard, Suite 3, San Fernando, CA 91340 www.stenengineering.com 1506 E Clemensen Ave & #212/12/2024 qa (psf) =1500 Allowable soil-bearing pressure P1 3156 *No pad provided for P1 as bearing area of 5 ft.2 provided by 15" wide by 24" deep wall footing is sufficient Pad Footings Area Provided, Ap=w2Area Required, Areq=P/qa (sf) Min. Pad Width, wmin=Areq 0.5 (ft) 5.00 Load Label Load, P (lbs) Pad Width Provided, wp (ft) N/A2.10 N/A 323-486-4151 info@stenengineering.com 501 South Brand Boulevard, Suite 3, San Fernando, CA 91340 www.stenengineering.com 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 1506 E Clemensen Ave & #212/12/2024 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org GRADING PERMIT REQUIREMENTS FOR DETACHED ADU PROJECTS PCC-15 REV: 09/03/2020 Page 1 of 1 A grading permit is required for all new detached buildings including new detached Accessory Dwelling Unit (ADU) projects. Grading plans prepared and stamped by a registered professional engineer shall be submitted for approval prior to issuance of the building permit, and shall be required to be submitted before or concurrently with the architectural plans submittal to the Building Safety Division. Grading Permit Exemption: Residential detached Accessory Dwelling Unit (ADU) projects that meet all of the following may be exempted from grading permit requirements: 1. The maximum amount of soil being moved is less than 50 cubic yards. The soil quantities shall be calculated by a California registered professional civil engineer 2. A site drainage plan prepared by a California registered professional civil engineer shall be provided with the following minimum information, but not limited to: a. Plan(s) shall be stamped, signed and dated by a California registered civil engineer b. Location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks c. Drainage slopes and flow patterns d. Drainage system such as swales, french drains, water collection and disposal system, etc. e. Drainage plan shall indicate how the site grading or drainage system will manage all surface water flows to be diverted away from buildings and adjoining property lines, in accordance with all applicable codes f. The grade shall fall not fewer than 6 inches within the first 10 feet from the foundation wall. Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains, or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet of the building foundation shall be sloped not less than 2 percent away from the building. 3. A final certification letter from the professional engineer of record stating that the grades were constructed per the approved site drainage plan, shall be submitted to the building inspector prior to final inspection 4. The “Detached ADU Grading Permit Exemption Checklist” shall be completed by the California registered professional civil engineer and shall be made a part of the building plans. 5. The site drainage plan and the completed checklist shall be required at the time of architectural plans submittal as part of the building plans package. The building official reserves the right to require a grading plan based on site conditions. This grading permit exemption does not apply to projects in the FEMA Flood Zone. 1506 E Clemensen Ave & #212/12/2024 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org DETACHED ADU - GRADING PERMIT EXEMPTION CHECKLIST PCC-16 REV: 11/10/2020 Page 1 of 1 THIS FORM SHALL BE COMPLETED BY A CALIFORNIA REGISTERED CIVIL ENGINEER. Instructions: In order to qualify for the grading permit exemption for detached Accessory Dwelling Unit (ADU) projects per handout PCC-15, the registered civil engineer of record shall complete all sections, check all boxes and sign the certification section below. A copy of this checklist shall be attached to each of TWO sets of plans. If answering NO to any of the questions, a grading plan and permit shall be required. Project Address: Yes No 1. ☐ ☐ I have verified that the project address is NOT located on a FEMA designated flood zone (Zone A or AE). 2. ☐ ☐ I have provided two sets of site drainage plans that is stamped, signed and dated by a California professional civil engineer, to be submitted with the building submittal package. 3. ☐ ☐ I have calculated the total amount of soil being cut or filled on this project is less than 50 cubic yards. 4. ☐ ☐ The site drainage plans include the following, but not limited to, location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks; drainage slopes and flow patterns, drainage systems such as swales, french drains, water collection and disposal systems, etc. 5. ☐ ☐ I have designed drainage such that surface water flows away from buildings and adjoining property lines, in accordance with all applicable codes. 6. ☐ ☐ I have designed grading such that it will not adversely affect the adjoining properties. 7. ☐ ☐ I have designed the grade to fall not fewer than 6 inches within the first 10 feet from the foundation walls except where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, I have designed drains or swales to ensure drainage away from the buildings. Any impervious surfaces within 10 feet of the building foundation are sloped not less than 2 percent away from the building. 8. ☐ ☐ I will provide a final certification letter stating that the grades were constructed per the approved site drainage plan, and will submit this certification letter to the building inspector prior to final inspection. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Licensed Number: Date: Phone Number: Email Address: x x x x x x x x 1506 Clemensen Avenue, Santa Ana, CA 92705 Ed Eckert R.C.E. 34587 04/17/2024 562-572-3507 / 626-804-5991 survey@millotengineering.com 1506 E Clemensen Ave & #212/12/2024