Loading...
HomeMy WebLinkAbout1601 W 2nd St - PlanDB Revision 'UDZQ%\ Description Date 'DWH 3URMHFW1DPH PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : 6KHHW6L]H 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 1 6 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 COMMERCIAL PHOTOVOLTAIC SYSTEM COMMUNITY ACTION PARTNERSHIP ORANGE COUNTY 1601 W 2ND ST, SANTA ANA, CA 92703 35.2 KW DC / 32.4 KW CEC AC SCOPE OF WORK SHEET INDEX GENERAL NO. ID. SHEET NAME 1 PV-0 TITLE SHEET PV-2 SINGLE LINE DIAGRAM 3 PV-6 VICINITY MAP SITE THE PROJECT SCOPE INCLUDES: 1. INSTALLATION OF ROOFTOP PHOTOVOLTAIC SYSTEM ON EXISTING RESIDENCE: 1601 W 2ND ST, SANTA ANA, CA 92703 PARCEL ID: 405-175-09 2. PHOTOVOLTAIC SYSTEM WILL BE INTERCONNECTED TO EXISTING MAIN SERVICE PANEL.. 3. TOTAL SYSTEM SIZE: 35.2 KW DC 32.4 KW CEC AC 4. TOTAL MODULES: (88) CANADIAN SOLAR CS3U-400MS STC RATING: 400 WATTS PTC RATING: 371.8 WATTS 5. TOTAL INVERTERS: (2) SOLAREDGE SE11400H-US INVERTER (1) SOLAREDGE SE5000H-US INVERTER CEC EFFICIENCY RATING 99.0% 6. UTILITY PROVIDER SOUTHERN CALIFORNIA EDISON 7. AUTHORITY HAVING JURISDICTION CITY OF SANTA ANA BUILDING AND SAFETY 8. ARRAY PLACEMENT: MOUNTED FLUSH TO SLOPED ROOF SURFACE. 9. ROOF TYPES: COMPOSITE SHINGLE 10. PV ARRAY HEIGHT: MAX 3" FROM TOP OF ROOFING CITY OF SANTA ANA APPLICABLE CODES APPLICABLE CODE AS OF JANUARY 1, 2023 PART 1 2022 CALIFORNIA BUILDING CODE, TITLE 24 C.C.R. PART 3 2022 CALIFORNIA ELECTRICAL CODE, TITLE 24 C.C.R. PART 6 2022 CALIFORNIA ENERGY CODE, TITLE 24 C.C.R. PART 9 2022 CALIFORNIA FIRE CODE, TITLE 24 C.C.R. PART 10 2022 CALIFORNIA EXISTING BUILDING CODE, TITLE 24 C.C.R. PROPERTY MAP N 5 PV-7 WARNING LABELS6 7 DAT A SHEETS PV-3 PV-5 AREA OF WORK PV-0 TITLE SHEET 2 PV-1 ROOF PLAN 8 DAT A SHEETS 4 PV-4 N F O R E S T A V E PV-89 PROPERTY LINE MOUNTING PLAN MOUNTING PLAN DAT A SHEETS PV-910 DAT A SHEETS W 2ND STREET Bldg# 101115409 Elec# 20179861 Issued 11/15/23 APPROVALS: PLNG - CSantana BLDG - JLo ELEC - MSmith 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Drawn By Description Date Date Project Name PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : Sheet Size 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 1 AHJ CORRECTIONS 8/1/23 2 AHJ CORRECTIONS 8/17/23 3 AHJ CORRECTIONS 10/11/23 PV-3 MOUNT PLAN J 7.4 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Description Date PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 PV-3 SINGLE LINE DIAGRAM MAKE MODEL MAX POWER OPEN CIRCUIT VOLTAGE MAX POWER POINT VOLTAGE SHORT CIRCUIT CURRENT MAX POWER POINT CURRENT PV MODULE RATINGS (A) CANADIAN SOLAR CS3U-400MS 400W 48.6V 40.8V 10.33A 9.81A GROUNDING TYPE NEGATIVE OCPD BREAKER SIZE CALCULATIONS: INVERTER MAX OUTPUT CURRENT X 125% INVERTER 1 - 47.5A X 125% = 59.4A , 60A OCPD BREAKER USED INVERTER 2 - 47.5A X 125% = 59.4A , 60A OCPD BREAKER USED INVERTER 3 - 21A X 125% = 26.3A , 30A OCPD BREAKER USED TOTAL: 60A + 60A + 30A = 150A OCPD 120% RULE CALCULATIONS PER NEC: TOP FED MAIN BREAKER BUSBAR X 120% - MAIN BREAKER > SOLAR BREAKER 600A (BUSBAR) X 120% - 500A (MAIN BREAKER) = 220A 220A BACKFEED CURRENT AVAILABLE MAKE MODEL MAX OUTPUT POWER MAX OUTPUT VOLTAGE MAX OUTPUT CURRENT MAX POWER POINT RANGE POWER OPTIMIZER RATINGS (B) SOLAREDGE S500B 500W 80V 15A 12.5 - 105V MAKE MODEL MAX OUTPUT POWER MAX DC VOLTAGE NOMINAL AC VOLTAGE MAX AC CURRENT CEC INVERTER EFFICIENCY INVERTER RATINGS (C) SOLAREDGE SE11400H-US 11400W 480V 240V 47.5A 99% AFCI PROTECTION INTEGRATED MAX STRING LENGTH 25 (NEW) 200A LOCKABLE NONFUSED OUTDOOR AC DISCONNECT INCOMING UTILITY VOLTAGE: 120V/240V, 1φ, 3W BIDIRECTION METER 500A MAIN BREAKER (DERATE) 60 0 A B U S B A R TOP FED MAIN SERVICE PANEL (EXISTING) 150A 150A SOLAR BREAKER (NEW-PV BREAKER SHALL BE LOCATED ON THE OPPOSITE SIDE OF MAIN SERVICE PANEL) UNDERGROUND SERVICE #500 AWG FEEDER CONDUCTOR EXISTING GROUND ELECTRODE 5 6 (36) MODULES (NEW) 11.4 KW SOLAR INVERTER #1 60A JUNCTION BOX C B A DC OPT DC OPT DC OPT (12) MODULES W/ (12) DC OPTIMIZERS 1 2 PV MOD PV MOD PV MOD (12) MODULES W/ (12) DC OPTIMIZERS 1 2 1.1 1.2 5 (12) MODULES W/ (12) DC OPTIMIZERS 1 2 1.3 (36) MODULES (NEW) 11.4 KW SOLAR INVERTER #2 60A JUNCTION BOX C B A DC OPT DC OPT DC OPT (11) MODULES W/ (11) DC OPTIMIZERS 1 2 PV MOD PV MOD PV MOD (13) MODULES W/ (13) DC OPTIMIZERS 1 2 2.1 2.2 (12) MODULES W/ (12) DC OPTIMIZERS 1 2 2.3 (16) MODULES (NEW) 5.0 KW SOLAR INVERTER #3 30A JUNCTION BOX D B A DC OPT DC OPT DC OPT (16) MODULES W/ (16) DC OPTIMIZERS 1 2 PV MOD PV MOD PV MOD 3.1 3 3 4 60A 200A PV SUBPANEL (NEW)30A 60A MAKE MODEL MAX OUTPUT POWER MAX DC VOLTAGE NOMINAL AC VOLTAGE MAX AC CURRENT CEC INVERTER EFFICIENCY INVERTER RATINGS (D) SOLAREDGE SE5000H-US 5000W 480V 240V 21A 99% AFCI PROTECTION INTEGRATED 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Description Date PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 PV-4 DERATE LETTER 1601 W 2nd St - 101115409 & 20179861 11/17/2023 1601 W 2nd St - 101115409 & 20179861 11/17/2023 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Description Date PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 REQUIRED WARNING LABELS PLACE ON ALL CONDUIT, LOCATED ON ROOF, INTERIOR AND EXTERIOR, EVERY 10' AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS AND ALL DC COMBINER AND JUNCTION BOXES IN 3 8" WHITE LETTERING ON RED BACKGROUND, ON FADE RESISTANT MATERIAL SYSTEM SIGNAGE ALL SIGNAGE SHALL BE IN PLASTIC, RED IN COLOR WITH WHITE LETTERING, AND ATTACHED WITH APPROVED ADHESIVE. ALL LETTERS SHALL BE A MINIMUM OF 3 8" HEIGHT AND ALL CAPITALIZED. CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: DISCONNECT PV-5 WARNING LABELSMAIN SERVICE SOLAR PHOTOVOLTAIC ARRAY ON ROOF #03-100#03-210 240 150 #03-353#03-314 #03-210 CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED 4" X 3" #03-701 INVERTERS #03-355 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Description Date PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 PV-6 DATA SHEET 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Description Date PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 PV-7 DATA SHEET 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Description Date PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 PV-8 DATA SHEET 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Description Date PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 PV-8 DATA SHEET 1601 W 2nd St - 101115409 & 20179861 11/17/2023 2.3 2.2 2.1 1.3 1.2 3.1 1.1 DB Revision Drawn By Description Date Date Project Name PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : Sheet Size 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 1 AHJ CORRECTIONS 8/1/23 PV-1 ROOF PLAN GENERAL NOTES: 1.IRONRIDGE FLASHFOOT MOUNTS WILL BE CONNECTED DIRECTLY TO THE EXISTING ROOF RAFTERS. 2.THE SPACING BETWEEN MOUNTS NOT TO EXCEED 48" O.C. IN EITHER DIRECTION 3.IRONRIDGE RAIL NOT TO CANTILEVER MORE THAN 20" FROM THE CLOSEST SUPPORT. 4.PV PANEL SYSTEM DEAD LOAD: 2.9 LBS/SQ FT 5.5/16" DIA LAG SCREW W/ 2-1/2" MIN EMBEDMENT. SITE PLAN SCALE: 1/16" = 1'-0" ROOF NOTES: 1.ROOF AZIMUTH: 90°, 180°, 270° 2.ROOF TILT: 23° 3.ROOF MATERIAL:COMPOSITE SHINGLE 4.BUILDING TYPE:COMMERCIAL 5.ROOF STRUCTURE:RAFTER 6.RAFTER SIZE:2x8 7.RAFTER SPACING:16" O.C. IRONRIDGE RAIL MOUNT POINT(88) 400W PV MODULES- FLUSH MOUNTED (NEW) 600A MAIN SERVICE PANEL (EXISTING) 5.0KW INVERTER (NEW) 200A AC DISCONNECT (NEW) 4' 4' 1'-6" 4' 4' MOUNT SPACING 1'-6" 1'-6" 11.4KW INVERTER (NEW) 11.4KW INVERTER (NEW) 200A SUBPANEL (NEW) PROPERTY LINE N F O R E S T A V E W 2ND STREET WAREHOUSE SPACE - NO SEPARATE ADDRESS UNOCCUPIED PATIO COVER 4' 4' 4' 4' 4' 1601 W 2nd St - 101115409 & 20179861 11/17/2023 DB Revision Drawn By Description Date Date Project Name PR O J E C T N A M E : PR O J E C T A D D R E S S : PA R C E L : Sheet Size 0 INITIAL SUBMITTAL 5/18/23 5/8/23 CO M M U N I T Y A C T I O N P A R T N E R S H I P OR A N G E C O U N T Y 16 0 1 W 2 N D S T , SA N T A A N A , C A 9 2 7 0 3 CAPOC-SANTA ANA Signature Dated 11x17 40 5 - 1 7 5 - 0 9 PL A N D E S I G N E R : DEREK BROSCH 11806 PALMS BOULEVARD LOS ANGELES, CA, 90066 OFFICE: (310) 488-2097 5/8/23 VIA SOLAR CORP DBA VIA CONSTRUCTION SERVICES LICENSE: B-992721 9702 KLINGERMAN STREET SOUTH EL MONTE, CA 91377 BUSINESS PHONE NUMBER:(626) 379-4649 Phone Number:(626) 579-4549 1 AHJ CORRECTIONS 8/1/23 2 AHJ CORRECTIONS 8/17/23 3 AHJ CORRECTIONS 10/11/23 PV-2 MOUNT PLAN 4.5" 2 x 8 RAFTERS @ 16" O.C. SEE SHEET PV-3 FOR DETAIL 1601 W 2nd St - 101115409 & 20179861 11/17/2023 1601 W. 2ND ST. SANTA ANA, CA 92703 COMMUNITY ACTION PARTNERSHIP Design Criteria 1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16 2 - Wind: 95 MPH, Exposure: C 3 - Wood Species: DF-L No. 2 (SG = 0.5 ) Notice: Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction & solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. 1-844-PV ELITE | info@yoursolarplans.com 3000 E. Birch Street Suite 201 | Brea CA 92821 6/7/2023 Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: Job: 1601 W 2nd St - 101115409 & 2017986111/17/2023     !"#$%!& '(!"&)''*+,'-'(.&','/010 1 +,120 '' 3 ..!..4..$ $.. !.. $4..56 . $..$!!. .  07)8 $9:;<=>?@AB<C;DEB@','/00  +,20 I  ')''*+,'-'+'4,),),   PI /['[[*'[Y *+[YY +-[YYY ',[Y\',[ F9JKTUV] XY',)Z.[ XY-)Z.+[ XY-,)Z.*-[ XY',,)Z.+'[X5."Y ',,[X5."YY '',[X5."YYY)Y\''-[ F9JKTU]^ 07),-/0..*-[ higjkfai`abalmnm_baoeajfkhpcfkfaqbeqjkekrahirahfcfqf`askedacqbkhpiaeghakfgqheghacrkiaidbghtf`audgeightjqiakiqvfgqhvbqjaccwxcabcc`qdeijqhogbrkhpaiobqrf`gcfqqeygf`f`aeqjkezdf`qbgfp{ksght|dbgcigjfgqhuaoqbavbqjaaightygf`iacgthwf`kff`az_~{kkbicup€qjkfgqhyaucgfaygeehqfuadvikfaifqcdvvqbfz ~‚ƒ„……w†ghiqdfy`pw..!.4[ˆ. 07 . ...$!..". . 07!!. ..!  ! ... 4.!.‰[..$..$!!.Š!..!$.. ..4.ˆ.$..!"!".‹Œ 7.$)..." ... !"..[.ˆ. "$[44.$.....$$)...""..[..!$."!!..Š[.4   !$[...$...!.ˆ...   [..!!!4  .[.!... !. ..!. 4.4!$ [...Š[ˆ.44  !!!."...4.! ... .44[.!.. Ž "[.4 [..4.!ˆ".Š...5$!."..4.!4  .4.4.. .4 4.!.."!".. !4..ˆ.$..2.4.4[4[ [.!!!!"4[  .2.4.  4$...[!ˆ!."ˆ." !"...!.4 !".ˆ!4. !"...! .!" .!.. ‘’“”•–”—”˜™š™›œššžŸ ¡¢£¤œ¢¥ •𦗔§”• ¦¦š¦ 1601 W 2nd St - 101115409 & 2017986111/17/2023 ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes. Roof Slope =23 ° Roof Shape Hip Tributary Width s =4.00 ft Tributary Length l =3.18 ft Effective Area Ae =12.73 f 2 Height of Structure h =25 ft Wind Speed V =95 mph Exposure Categor C Building Width B =55 ft Building Length L =55 ft Zone Width a =5.5 ft Elevation Height zg =91 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.95 Velocity Pressure qz = 0.00256KzKztKdKeV2 =18.50 psf Solar Array Pressure Equalization a =0.79 Array Edge Factor E =1.50 Zone GCp p = qz(GCp)(E)(a) 3 1.99 -43.42 3r - - 3e - - 2 - - 2r 1.99 -43.42 2e 1.99 -43.42 2n - - 1 1.38 -30.21 1' - - 1601 W 2nd St - 101115409 & 2017986111/17/2023 LAG SCREW ANALYSIS Loads Wind Pressures qz =-43.42 psf Solar Panel Load QD =3 psf Panel Length l =6.367 ft Panel Width b 3.4417 ft Attachment Spacing s =4 ft Portrait Tributary Area At =12.73 ft2 Wind Load PW = qz * At =-553 lbs Dead Load PD = QD * At =38.2 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-309 lbs Landscape Tributary Area At = b * s =6.8833 ft2 Wind Load PW = qz * At =-299 lbs Dead Load PD = QD * At =20.65 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-167 lbs Lag Screw Specific Gravity of Lumber SG =0.50 (Douglas Fir-Larch) Diameter of Lag Screw D =5/16 in Withdraw Design /in 1800*SG3/2*D3/4 =266 lbs/in Depth of Embedment lp =2.50 in Total Nominal Withdrawal Value W = W * l p =665 lbs Load Duration Factor CD =1.6 Withdrawal Design Value W' = W * C D =1064 lbs Demand Capacity Ratio DCR = Pa / W'=0.29 < 1 OK 1601 W 2nd St - 101115409 & 2017986111/17/2023 ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check Roof Slope =23 ° Roof Shape Hip Tributary Width s =1.33 ft Tributary Length L =34.34 ft Effective Area A = L ( MAX [ s , L/3] )=100 f 2 Height of Structure h =25 ft Wind Speed V =95 mph Exposure Categor C Building Width B =55 ft Building Length L =55 ft Zone Width a =5.5 ft Elevation Height zg =91 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.95 Velocity Pressure qz = 0.00256KzKztKdKeV2 =18.50 psf Internal Pressure Coefficient (GCpi)=-0.18 Zone GCp p = qz [(GCp) - (Gcpi)] 3 1.53 -31.57 3r - - 3e - - 2 - - 2r 1.53 -31.57 2e 1.53 -31.57 2n - - 1 0.80 -18.13 1' - - 1601 W 2nd St - 101115409 & 2017986111/17/2023 Beam/ Top Chord Check Lumber: Moment Demand # of Attachment per Rafter NA =Span :Orientation Lenght (ft) : Dead Load Roof Material:QD =psf Live Load QLr =psf Wind Load p = psf Snow Load QS =psf Rafter Spacing s = in Wind Load, Portrait Portrait UL = Wind Load, Landscape Landscape UW = Linear Dead Load wd =plf Live Load wLr = plf Start ft Start ft End ft End ft Snow Load ws = plf Start ft Start ft End ft End ft Ma, Moment D lb-ft D+Lr lb-ft D+S lb-ft 0.6D+0.6W lb-ft D+0.45W+0.75Lr lb-ft D+0.45W+0.75S lb-ft Moment Capacity Framing Member Size Lumber Grade : DF-L No. 2 CM = 1 Ct = 1 Cr= CF = fb =psi Cfu =Ci = Breadth b = in Depth d = in Section Modulus Sx = bd2 / 6 =in3 Bending Stress Capacity Fb = CM * Ct * Cr * CF * fb =psi Table 4.3.1 NDS 2018 Deflection Limit E = ksi I =in4 Transient Deflection in Transient Deflection Allowed > [OKAY] Total Deflection in Total Deflection Allowed > [OKAY] -31.57 DF-L No. 2 10 j lj (ft)pd,j (lbs) pw,j (lbs) ps,j (lbs) Portrait 1 2.3 38.2 -402 0.0 7.0 38.2 -402 -402 0.0 4 13.4 38.2 -402 0.0 0.0 15.17 18.17 0.00 0.00 1.00 Portrait 3 8.7 38.2 10.00 1 2 3 4 Eave 2 0.0 38.2 -402.0 0.0 0.0 8 26.1 38.2 -402.0 0.0 7 21.4 38.2 -402.0 0.0 6 19.8 38.2 -402 0.0Portrait5 15.1 38.2 -402 0.0 13.3 26.7 0.0 0.0 0.0 0.0 0 0.0Portrait0 0.020.65 -217 0 0 0.0 0 1.5 0 10 -402.0 Portrait 1.5 32.5Portrait9 27.8 38.2 AT (ft2) 12.733 6.8833 pd (lbs) 38.2 -402 pw (lbs) ps (lbs) 0 33.33 2x8 1.15 1.2 34.34 33.33 34.34 900 1.50 7.25 875 877 875 2019 1033 1033 DCR 0.9 1118 psi D 799 psi 0.71 13.1 1242 CD Fb' = CD * Fb ASD Load Ma / Sx 1.15 1428 psi D+S 799 psi 0.56 OKAY OKAY 1.25 1553 psi D+Lr 801 psi 0.52 OKAY 1.6 1987 psi 0.949 230 120 1600 47.63 0.6D+0.6W 1843 psi 0.93 OKAY 1.0 1 20 0.00 16 Comp 0.832 262 180 1.6 1987 psi D+0.45W+0.75S 943 psi 0.47 OKAY 1.6 1987 psi D+0.45W+0.75L 943 psi 0.47 OKAY 𝑴𝒙 𝑹𝒊𝒙 𝑳𝒊 𝑷𝒋𝒙 𝒍𝒋 𝒘𝒅𝒙𝟐 𝟐 ‐3000.0 ‐2000.0 ‐1000.0 0.0 1000.0 2000.0 0.000 5.000 10.000 15.000 20.000 25.000 30.000 35.000 40.000 1601 W 2nd St - 101115409 & 2017986111/17/2023 EISMIC WEIGHT COMPARISON / ANALYSIS - (PER CEBC 2022 Part 10 Chapter 5 Section 502.5) PV System Weight Module Model CS Panel Weight W panel = 49.6 lbs Number of Panels NPV = 88 Total PV System Weight W PV = W panel * NPV =4365 lbs Existing Roof Weight Roof Weight QD =10.0 psf Building Length Lbuild =55 ft Building Width W build =55 ft Roof Area Abuild =3025 ft2 Building Perimeter Pbuild =220 ft Wall Height ht =8 ft Wall weight Qwall =15 psf Interior wall weight Qint =10 psf Roof Load W floor = Abuild * QD =30250 lbs Wall Load wall = ht /2 * Qwall * Pbuild + Abuild * Qint /=28325 lbs Total Story Weight W build = W floor + W wall =58575 lbs Percentage Weight Increas WPV / Wbuild = 7.45% < 10% OKAY 1601 W 2nd St - 101115409 & 2017986111/17/2023