HomeMy WebLinkAbout1605 E 4th St - PlanCOVER PAGE (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATE DESCRIPTION REVISIONS PROJECT NAME & ADDRESS HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022 FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022 MODULE LAYOUT C04/19/2023 REVISION D09/26/2023 REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S PROJECT DESCRIPTION: THIS ROOF-MOUNTED SOLAR PHOTOVOLTAIC (PV) -23.520KW(DC STC) SYSTEM IS TO BE INSTALLED AT THE HINER PARTNERS LOCATED IN SANTA ANA, CA 92701. THE ENERGY PRODUCED BY THE PV SYSTEM SHALL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH EXISTING ON-SITE ELECTRICAL EQUIPMENT VIA BACKFEED BREAKER IN THE EXISTING DISTRIBUTION PANEL LOCATED TO THE BUILDING. VICINITY MAP 2 PROJECT LOCATION AERIAL MAP 1 GENERAL NOTES: 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY. 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED. 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER/ALUMINUM. 5. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 7. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL CONTRACTOR TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 8. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS. 9. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK. 10. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 11.CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY. PHOTOVOLTAIC NOTES: 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 5. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8. INVERTER IS EQUIPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION. 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED. 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6). 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS AS PER NEC 690.47(C) AND SIZED AS PER SEC 250.166. 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-166. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS. 17.110.2 APPROVAL:ALL ELECTRICAL EQUIPMENT SHALL BE LABELED,LISTED OR CERTIFIED BY A NATIONAL RECOGNIZED TESTEING LABORATORY ACCREDITED BY THE UNITED STATES OCCUPATIONAL SAFETY HEALTH ADMINISTRATION. SHEET INDEX S.NO SHEET NAME PV-1 COVER PAGE PV-2 SITE PLAN PV-3 ROOF PV LAYOUT PV-4 STRING LAYOUT PV-5 ATTACHMENT DETAIL PV-6 ELECTRICAL LINE DIAGRAM PV-7 ELECTRICAL CALCULATION PV-8 SAFETY PLACARDS PV-9 MODULE & INVERTER DATA SHEET PV-10 RACKING & ATTACHMENT DATA SHEET PV-11 COVER SHEET PV-12 KEY PLAN PV-13 ARRAY LAYOUTS PV-14 RM5 DETAILS PV-15 RM5 DETAILS ELECTRICAL INFORMATION: (E) DISTRIBUTION PANEL BUS SIZE: 400A MAX AC VOLTAGE: 120/208V; 3P, 4WIRE (N) 1 - SOLAREDGE SE17.3KUS INVERTER (N) 1 - AC DISCONNECT : 100A, NEMA 3R (UNFUSED) (N) JUNCTION BOX, 1000V OWNER INFORMATION: HINER PARTNERS (23.520KW DC) 1605 E 4TH ST SANTA ANA, CA 92701, USA GOVERNING CODES:- · 2022 CA BUILDING CODE · 2022 CA RESIDENTIAL CODE · 2022 CA MECHANICAL CODE · 2022 CA ELECTRICAL CODE · 2022 CA GREEN CODE · 2022 CA PLUMBING CODE · 2022 CA ENERGY CODE · 2022 CA FIRE CODE ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES PHOTOVOLTAIC SYSTEM SUMMARY:- SYSTEM SIZE: DC STC: 21.120 KW SYSTEM SIZE: AC CEC / PTC: 19.460 KW SOLAR MODULES: (44) HANWHA Q CELLS 480WATT MODEL #: (Q.PEAK DUO XL-G10.3/BFG) INVERTER: SOLAREDGE MODEL #: (1) SE17.3KUS OPTIMIZER: (1) SOLAREDGE MODEL #: (22) P1101 MOUNTING SYSTEM: UNIRAC BALLESTED RM5 INVERTER AC OUTPUT: 1*17300 W = 17.30 KW PROJECT INFORMATION: · APN: N/A · AHJ: SANTA ANA CITY · PANEL UPGRADE: NO · FIRE RATING: CLASS 'A' TYPE 1 · NO. OF FLOORS: 1 TYPE: III-B OCCUPANCY: B - BUSINESS 0-Title Bldg# 101113848 Elec# 20178713 Issued 11/13/23 APPROVALS: PLNG - HJacinto BLDG - JLo ELEC - MSmith 1605 E 4th St - 101113848 and 20178713 11/15/2023 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 1605 E 4th St - 101113848 and 20178713 11/15/2023 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 1605 E 4th St - 101113848 and 20178713 11/15/2023 (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION D09/26/2023REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S DIAGRAM ELECTRICAL LINE 1 ELECTRICAL LINE DIAGRAM PV-6 SCALE: NTS PV MODULE SPECIFICATIONS Model Number: Q.PEAK DUO XL-G10.3/BFG MODULES Weight:64.20 lbs Dimensions:87.2"L x 41.1"W x 1.38"D (In Inch) Power @ STC:480 Watts Rated Voltage (Vmpp)45.33 Volt Rated Current (Impp)10.59 Amps Open-Circuit Voltage (Voc)53.39 Volt Short-Circuit Current (Isc)11.12 Amps Voc Temp Coeff:-0.26 %/°C Inverter specifications Manufacturer/ Model Number:SOLAREDGE SE17.3KUS Nominal ac power 17300.0 W Nominal output voltage 208 Volt Nominal output current (per phase)48.25 Amps Max dc input voltage 600 Volt CEC efficiency 97.5 % Maximum input power 26000.00 W Maximum output power 17300.0 W TO UTILITY GRID GEC G GROUNDING ELECTRODE SYSTEM BI-DIRECTIONAL UTILITY METER 3-PHASE, 4-W 120/208VM (3) #6 AWG THWN-2 (1) #8 AWG THHN EGC 1" EMT CONDUIT (E) 400A MAIN BREAKER DISCONNECT, 400A/3PHASE (2) #10 AWG THWN-2 + RED (2) #10 AWG THWN-2 - BLACK (1)#8 AWG THHN EGC 3/4" EMT CONDUIT JUNCTION BOX 1000 V, NEMA 3R UL LISTED (N) 70A PV BREAKER AT OPPOSITE END OF BUS FROM BREAKER (E) MAIN SERVICE PANEL, 400A RATED, 120/208V, 3-PHASE, 4-W 70A 1 ~ = STRING #1 2 (N) UNFUSED AC DISCONNECT, 100A, 120/208V, 3P, 4W, NEMA 3R, UL LISTED 21 22 INVERTER SOLAREDGE SE17.3KUS 120/208 VAC, 48.25A, 97.5% CEC WEIGHTED EFFICIENCY NEMA 4X, UL LISTED, INTERNAL GFDI WITH INTEGRATED DC DISCONNECT = DC AC (1) 10 AWG 1000VDC PV WIRE + RED (1) #10 AWG 1000VDC PV WIRE - BLACK (1)#6 AWG EGC BARE COPPER 120% RULE BUS BAR 400 MAIN BREAKER 400 ALLOWED MAX PV OCPD 80 Optimizer specifications Manufacturer/ Model Number:SOLAREDGE P1101 Maximum dc input power 1101.0 Watt Maximum input voltage 125 Volt Maximum Short Circuit Current (Isc)14.1 Amps Maximum output current 18 Amps Maximum Watts per string 8820.0 Watt (44) Q.PEAK DUO XL-G10.3/BFG (480W) MODULES (02) STRINGS OF 22 MODULES CONNECTED IN SERIES ~ = 1 ~ = STRING #2 2 21 22 ~ = PHOTOVOLTAIC SYSTEM SUMMARY:- SYSTEM SIZE: DC STC: 21.120 KW SYSTEM SIZE: AC CEC / PTC: 19.460 KW SOLAR MODULES: (44) HANWHA Q CELLS 480WATT MODEL #: (Q.PEAK DUO XL-G10.3/BFG) INVERTER: SOLAREDGE MODEL #: (1) SE17.3KUS OPTIMIZER: (1) SOLAREDGE MODEL #: (22) P1101 MOUNTING SYSTEM: UNIRAC BALLESTED RM5 INVERTER AC OUTPUT: 1*17300 W = 17.30 KW E-1.0 1605 E 4th St - 101113848 and 20178713 11/15/2023 (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION D09/26/2023REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 2°C AMBIENT TEMP (HIGH TEMP 2%)31°C CONDUIT HEIGHT(0-6 inch)0°C ROOF TOP TEMP 31°C NUMBER OF CURRENT CARRYING CONDUCTORS IN RMC PERCENT OF VALUES 4-6 0.80 7-9 0.70 10-20 0.50 CONDUCTOR AMPACITY CALCULATIONS: JUNCTION BOX TO COMBINER BOX: AMBIENT TEMPERATURE ADJUSTMENT FOR EXPOSED CONDUIT PER NEC 310.15(B)(2)(c)0°C EXPECTED WIRE TEMP (In Celsius)31°C TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 4 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)0.80 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 22.50A 1.25 X INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 30.72ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY (0.71X0.80X40) Result should be greater than (22.50A) otherwise less the entry for circuit conductor size and ampacity 1.GEC TO BE INSTALL AS REQUIRED BY MANUFACTURER INSTRUCTIONS AND NEC 690.47 2.PER NEC 690.64 B.2: THE SUM OF THE AMPERE RATINGS OF OVER CURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUS BAR SHALL NOT EXCEED 120% THE RATING OF THE BUS BAR OR CONDUCTOR FOR A DWELLING UNIT. 3.THE PV PANELS AND THE INVERTERS REQUIRE NEGATIVE GROUNDING PER MANUFACTURE'S INSTRUCTIONS. 4.ANTI-ISLANDING PROTECTION ENSURES THE SYSTEM WILL NOT EXPORT POWER INTO A BALANCED 60 Hz RESONANT LOAD WHILE THE UTILITY IS DISCONNECTED. 5.PER NEC 690.64(B)(7): UNLESS THE PANEL BOARD IS RATED NOT LESS THAN THE SUM OF THE AMPERE RATINGS OF ALL OVER CURRENT DEVICES SUPPLYING IT, A CONNECTION IN A PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION. THE BUS OR CONDUCTOR RATING SHALL BE SIZED FOR THE LOADS CONNECTED IN ACCORDANCE WITH ARTICLE 220. A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT WITH THE FOLLOWING OR EQUIVALENT MARKING: "WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER CURRENT DEVICE" ELECTRICAL NOTES CALCULATIONS ELECTRICAL 1 ELECTRICAL CALCULATION SCALE: NTSPV-7 VD = 1.732 x K x L x I / CM VD% = VD/Service Voltage (208V) K = ohms - cmil per ft I = Current (amperes) of load L = Length of conductor in Ft. (one-way) CM = circular mil area of conductor K (Cu) = 12.9 K (Al) = 21.2 VOLTAGE DROP CALCULATION (3PHASE)(AC) VD = 2 x K x L x I / CM VD% = VD/Max DC Voltage of String K = ohms - cmil per ft I = Current (amperes) of load L = Length of conductor in Ft. (one-way) CM = circular mil area of conductor K (Cu) = 12.9 K (Al) = 21.2 VOLTAGE DROP CALCULATION (DC) CONDUCTOR AMPACITY CALCULATIONS: ARRAY TO JUNCTION BOX: EXPECTED WIRE TEMP (In Celsius)31°C TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 2 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1.00 CIRCUIT CONDUCTOR SIZE 10AWG CIRCUIT CONDUCTOR AMPACITY 40A REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(A&B) 22.50A 1.25 X INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 38.40ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (22.50A) otherwise less the entry for circuit conductor size and ampacity DC VOLTAGE DROP CALCULATION Wire material Copper Copper Section DC1 DC2 Wire size 10 AWG 10 AWG 2 2 2 Current (amperes) of load (I)18 18 Length of conductor in Ft. (one-way) (L)50 50 Ohms - cmil per ft (K)12.9 12.9 2 X I X L X K 23220 23220 Circular mil area of conductor (CM)10380 10380 Voltage drop 2.237 2.237 Voltage drop (%)0.370 0.370 Optimizer specifications Manufacturer/ Model Number:SOLAREDGE P1101 Maximum dc input power 1101.0 Watt Maximum input voltage 125 Volt Maximum Short Circuit Current (Isc)14.1 Amps Maximum output current 18 Amps Maximum Watts per string 8820.0 Watt CONDUCTOR AMPACITY CALCULATIONS: COMBINER BOX TO MAIN PANEL: REQUIRED CIRCUIT CONDUCTOR AMPACITY PER NEC 690.8(B) 60.31A 1.25 X MAX INVERTER OUTPUT CURRENT DERATED AMPACITY OF CIRCUIT CONDUCTOR PER NEC TABLE 310.16 72.00ATEMP. CORRECTION PER TABLE (310.16) X CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a) X CIRCUIT CONDUCTOR AMPACITY Result should be greater than (60.31A) otherwise less the entry for circuit conductor size and ampacity EXPECTED WIRE TEMP (In Celsius)31°C TEMP. CORRECTION PER TABLE (310.16)0.96 NO. OF CURRENT CARRYING CONDUCTORS 3 CONDUIT FILL CORRECTION PER NEC 310.15(B)(2)(a)1.00 CIRCUIT CONDUCTOR SIZE 6 AWG CIRCUIT CONDUCTOR AMPACITY 75A PV MODULE SPECIFICATIONS Model Number: Q.PEAK DUO XL-G10.3/BFG MODULES Weight:64.20 lbs Dimensions:87.2"L x 41.1"W x 1.38"D (In Inch) Power @ STC:480 Watts Rated Voltage (Vmpp)45.33 Volt Rated Current (Impp)10.59 Amps Open-Circuit Voltage (Voc)53.39 Volt Short-Circuit Current (Isc)11.12 Amps Voc Temp Coeff:-0.26 %/°C Inverter specifications Manufacturer/ Model Number:SOLAREDGE SE17.3KUS Nominal ac power 17300.0 W Nominal output voltage 208 Volt Nominal output current (per phase)48.25 Amps Max dc input voltage 600 Volt CEC efficiency 97.5 % Maximum input power 26000.00 W Maximum output power 17300.0 W AC VOLTAGE DROP CALCULATION Wire material Copper Copper Section AC1 AC2 Wire size 6 AWG 6 AWG √3 1.732 1.732 Current (amperes) of load (I)60.31 60.31 Length of conductor in Ft. (one-way) (L)10 10 Ohms - cmil per ft (K)12.9 12.9 √3 X I X L X K 13475 13475 Circular mil area of conductor (CM)26240 26240 Parallel No No Conductors 1 1 Voltage drop 0.514 0.514 Voltage drop (%)0.247 0.247 E-2.0 1605 E 4th St - 101113848 and 20178713 11/15/2023 (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION D09/26/2023REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S PLACARD SAFETY NOTES AND SPECIFICATIONS: ·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ. ·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE WORDS, COLORS AND SYMBOLS. ·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HAND WRITTEN. ·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. ·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED. ·DO NOT COVER EXISTING MANUFACTURER LABELS. WARNING: PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACH TURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S): 690.31(G)(4) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): 605.11.1 MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 48.25 AMPS 208 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED ELECTRICAL SHOCK HAZARD WARNING LABEL LOCATION: INVERTER(S), DC DISCONNECTS. PER CODE(S): 690.35(F) PV SYSTEM DISCONNECT FOR UTILITY OPERATION SOLAR AC DISCONNECT ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): 690.17(E) CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED WARNING DO NOT RELOCATE THIS OVERCURRENT DEVICE INVERTER OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): 705.12(D)(4) LABEL LOCATION: MAIN SERVICE DISCONNECT LABEL LOCATION: SOLAR AC DISCONNECT LABEL LOCATION: UTILITY AC DISCONNECT PLAQUE SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): 705.12(D)(2)(3)(c) ! ! ! CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECT AS SHOWN MIN.6"x6" PLACARD TO GO ON MAIN SERVICE PANEL WARNING: DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM RATED AC OUTPUT CURRENT 50.04 AMPS AC NOMINAL OPERATING VOLTAGE 208 VOLTS LABEL LOCATION: LOAD CENTER [Only use when applicable for PV load center] NOTICE PV SYSTEM COMBINER PANEL DO NOT ADD LOADS TO THIS PANEL YOU ARE HERE SERVICE POINT UTILITY METER PV DISCONNECT INVERTER E 4TH ST EA S T S I D E A V E E-3.0 1605 E 4th St - 101113848 and 20178713 11/15/2023 (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS PV-9 HI N E R P A R T N E R S 16 0 5 E 4 T H S T SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT DATA SHEET INVERTER MODULE & 1605 E 4th St - 101113848 and 20178713 11/15/2023 1/6/2023 RE: Structural Certification for Solar Installation Hiner Partners:1605 E 4TH ST, SANTA ANA, CA 92701, USA Attn: To Whom It May Concern Design Criteria Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 95 mph PV Dead Load DPV 4.6 psf (with Ballast)Exposure B Roof Live Load Lr 20 psf This Letter is for the existing roof framing which will support ballasted PV modules. From the site survey, the roof is made of Flat Rolled Composition roofing over roof plywood supported by 2X4 Rafters at 24 inches on a relatively flat roof. The slope of the ballast tilt is approximated to be 5 degrees. the existing roof framing has been determined to be adequate to support an additional dead weight without structural upgrades. To avoid structural updgrades and/or additional analysis for the lateral resisting system, additional Weight should not exceed that covered in the report. Parameters above ensure that the seismic weight increase is less than 10%. More dead weight can be added only after further analysis of the lateral resisting system are performed. Ballasts seismic and uplift resistance as well as layout are derived and covered by The Ballast report.Capacity calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com Structural Only 1605 E 4th St - 101113848 and 20178713 11/15/2023 Structural Letter for PV Installation Date:1/6/2023 Job Address:1605 E 4TH ST SANTA ANA, CA 92701, USA Job Name:Hiner Partners Job Number:220105HP Scope of Work Table of Content Sheet 2 Cover 3 Roof Framing Check 4 Seismic Check and Scope of work Ballast Report Engineering Calculations Summary Code 2022 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 4.6 psf (with Ballast) Roof Live Load Lr 20 psf References PV system to existing roof framing. All PV mounting equipment shall be designed and installed per projects@evengineersnet.com http://www.evengineersnet.com Structural Only 1605 E 4th St - 101113848 and 20178713 11/15/2023 Vertical Load Resisting System Design Roof Framing Rafters Fully Exposed pg=0 psf 1.1 0.9 1.0 ps = 0 psf pf = 0 psf pfmin. = 0.0 psf 0 plf Max Length, L =8.0 ft Tributary Width, WT =24 in RLL =20 psf 39.85 plf Dr =10 psf 20 plf Load Case: DL OK Load Case: DL+RLL OK Load Case: DL+S OK Load Case: DL+0.6W OK Load Case: 0.6DL+0.6W OK DL+0.45W+0.75(RLL or S)31 plf OK Member Capacity 2X4 φ λ Cross-Sectonal Area, A =5.25 in Satisfactory Satisfactory projects@evengineersnet.com http://www.evengineersnet.com 1605 E 4th St - 101113848 and 20178713 11/15/2023 Siesmic Loads Check Roof DL 10 psf Ext. Wall DL 18 psf Areas (s 3405 40.9 kips 2334 42.0 kips 82.9 kips Max additional Weight= 10%8.29 kips 1362 qft 6.08 psf Governs Solar Weight to use=psf OK Limits of Scope of Work and Liability The increase in global seismic Dead weight as a result of the solar system will be less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans -Hiner Partners. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally Seismic Weight 6 projects@evengineersnet.com http://www.evengineersnet.com 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs Legend: Base System Part Accessory NA - User Supplied 44 310800 69 310830 0 310820 222 310860 246 310811 10 310861 24 310850 44 310851 5 008002S 0 008009P 2 NA - User Supplied 96 GROUNDING LUG ILSCO LAY IN LUG (GBL4DBT) GROUNDING LUG GROUND WEEBLUG #1 PROJECT REPORT VERSION:INT 10.20.22 9-9-23 2:47 PM BILL OF MATERIALS PARTS AND ACCESSORIES RM5/DT 1/4-20 CLIP U-NUT SS18-8 WIND DEFLECTOR RM5 WIND DEFLECTOR, 98" WIRE MGMT CLIP RM5 WD WIRE MGMT CLIP DEFLECTOR HARDWARE RM5, WIND DEFLECTOR HDW KIT WIRE MGMT CLIP RM5/DT WIRE MGMT CLIP Module ENDCLAMP RM5/DT PVC ROOF FRICTION PATCH Part Number Module BAY RM5 BAY Part Type Description Quantity FRICTION PATCH Ballast Block 32 lb. Concrete Block w/4x8x16 in. Nom. Dim. (ASTM C1491 (Concrete Roof Pavers)) RM5/DT ENDCLAMP 30-40MM NUT This design is to be evaluated to the product appropriate Unirac code compliant Installation Guide which references the ASCE 7-16. The installation of products related to this design is subject to requirements in the above mentioned Installation Guide. 1 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs 4.66 psf RM5 (5 Degree Tilt) 6289 lbs Hanwha/Q-Cells 646 lbs Q.Peak Duo XL-G10.2- 2570 lbs 3072 lbs 86.93 in 148 lbs 40.83 in 16.00 psf 1.38 in 24.6 sqft 58.4 lbs 211 lbs I Ballast Block Weight:32.0 lbs Max Blocks per Bay:2 Loads Used for Design Building Height:22 ft - Building Code:ASCE 7-16 Roof Type:TPO - Wind Speed:95 mph Parapet Height:1 Array Height - Ground Snow Load:0 psf Row Spacing:7.5 in - Seismic (Ss):1.29 g Roof Pitch:<= 3 Degrees* - Wind Exposure:B - Risk Category:II - Seismic Design Category:D AVERAGE PSF:Product: Total weight on roof: - Racking weight: Module Length: - Max Bay Load (Dead): Module Width: - Down Wind (qh*GCp down): PROJECT REPORT VERSION:INT 10.20.22 INSPECTION ENGINEERING REPORT PLAN REVIEW Module Thickness: - Module Area: Module Weight: - Max Bay Down Load (Total): - Ballast weight: - Module weight: Module Watts:480 watts Module Type: NOTE: IF ROOF PITCH IS >3 DEGREES, PLEASE CONTACT UNIRAC FOR MORE DETAILS Model: Module Manufacturer: 9-9-23 2:47 PM 2 1605 E 4th St - 101113848 and 20178713 11/15/2023 - Array to Array:12 in - To Obstruction or Parapet:24 in - To Roof Edge (No Parapet):48 in Max Array (Seismic) (For Unattached Arrays) Minimum Seismic Separation (Unattached Arrays): Array 1 2 AVERAGE PSF:4.16 psf 5.54 psf Total Number of Modules 28 16 Total KW:13.44 kWs 7.68 kWs Total Area:856 Sq Ft. 493 Sq Ft. Total weight on roof:3557 lbs 2732 lbs - Racking weight:385 lbs 261 lbs - Module weight:1636 lbs 935 lbs - Ballast weight:1536 lbs 1536 lbs Array 1 2 Max rows 16 14 Max columns 13 11 3 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs ~ 37 ft ~ 56 ft VERSION:INT 10.20.22 9-9-23 2:47 PM INSTALLATION AND DESIGN PLAN PROJECT REPORT M Module with No Deflector N Module with North Deflector S Module with South Deflector NS Module with North and South Deflector 2 Bay with Block Count 2 Two Supplementary Bay required Legend Array 2 Array 1 2 0 2 0 2 0 2 0 2 0 2 0 2 N N N N N N 1 0 1 0 1 0 1 0 1 0 1 0 1 M M M M M M 1 0 1 0 1 0 1 0 1 0 1 0 1 M M M M M M 1 0 1 0 1 0 1 0 1 0 1 0 1 M M M M M M 1 0 1 0 1 0 1 0 1 0 1 0 1 M M M M 1 0 1 0 1 0 0 0 1 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 2 0 2 0 2 0 2 0 0 0 0 N N N N 1 0 1 0 1 0 1 0 1 0 0 0 0 M M M M 2 0 2 0 2 0 2 2 2 0 0 0 0 M M 0 0 2 0 2 0 2 0 0 0 0 0 0 M M 0 0 2 0 2 0 2 0 0 0 0 0 0 M M 0 0 2 0 2 0 2 0 0 0 0 0 0 M M 0 0 1 0 1 0 1 0 0 0 0 0 0 4 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs Site Classification:D-Default Ss:1.29 g Risk Category:II Fa:1.20 SMS:1.54 g SDS:1.03 g Module Weight:58 lbs Racking and Ballast Weight to One Module:89 lbs Capacity of Connections to One Module (N/S):348 lbs Capacity of Connections to One Module (E/W):284 lbs W1 (Module, Racking, and Ballast Weight to One Module):148 lbs 0.2 SDS W1:20.2 Seismic Design category D Building Importance Factor:1.00 Importance Factor of Array:1.00 Design for Seismic Separation DMPV=[5Ie(SDS-0.4)^2*12 in] or 24 in:24 in ←ASCE 7-16, 13.6.12 Setback Between Arrays (0.5DMPV):12 in ←ASCE 7-16,13.6.12 Setback Between Array and Objects (DMPV):24 in ←ASCE 7-16, 13.6.12 Setback Between Array and Edge of Parapet (DMPV):24 in ←ASCE 7-16,13.6.12 Setback Between Array and Roof Edge without Parapet (2*DMPV):48 in ←ASCE 7-16, 13.6.12 9-9-23 2:47 PM PROJECT REPORT VERSION:INT 10.20.22 SEISMIC DESIGN PER ASCE 7-16, 13.6.12 SEISMIC DESIGN 5 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs Elevation 139 ft Numerical coefficient - Imperial Units 0.00255 ← Sec on 26.10.1 (ASCE 7-16) Median Roof Height, h 22 ft Exposure B ← Sec on 26.7 (ASCE 7-16) Risk Category II ← Table 1.5-1 (ASCE 7-16) Basic Wind Speed, V 95 mph Velocity Pressure Exposure Coefficient, Kz 0.70 ← Table 26.10.1 (ASCE 7-16) Topographic Factor (assuming level ground), Kzt 1.00 ← Sec on 26.8 (ASCE 7-16) Directionality factor, Kd 0.85 ← Table 26.6-1 (ASCE 7-16) Velocity Pressure at Height qh = 0.00255KzKztKdV2 13.7 psf ← Equa on 26.10.1 (ASCE 7-16) Design Life Factor, Kdl 1.00 ← Equa on C26.5-4 (ASCE 7-16) Design Life Velocity Pressure qh x Kdl 2 13.7 psf Design pressure p = qhGCp WIND DESIGN 9-9-23 2:47 PM WIND DESIGN VERSION:INT 10.20.22 PROJECT REPORT 6 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs UPLIFT CALCULATIONS VERSION:INT 10.20.22 PROJECT REPORT TOTAL WIND UPLIFT (0.6 X GCP X QZ X A) (LBS) SYSTEM DEAD LOAD (1 X DL) (LBS) UPLIFT LESS SYSTEM DL PER MODULE (LBS) MODIFIED GCP FACTOR PER MODULE PROJECT UPLIFT SYSTEM CHECK 9-9-23 2:47 PM Array 1 2 UPLIFT (0.6 X GCP X QZ X A) (LBS) -2435 lbs -1999 lbs SYSTEM DEAD LOAD (1 X DL) (LBS) 2021 lbs 1196 lbs Ballast Dead Load (1X DL): 1536 lbs 1536 lbs Check if Dead Load > Uplift OK OK -0.32 -0.30 -0.30 -0.30 -0.30 -0.32 -0.48 -0.36 -0.36 -0.36 -0.36 -0.48 -0.48 -0.36 -0.36 -0.36 -0.36 -0.48 -0.46 -0.38 -0.54 -0.54 -0.38 -0.46 -0.67 -0.67 0.00 0.00 -0.67 -0.67 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.37 -0.39 -0.39 -0.48 0.00 0.00 -0.82 -0.40 -0.52 -0.82 0.00 0.00 0.00 -0.82 -0.82 0.00 0.00 0.00 0.00 -0.67 -0.67 0.00 0.00 0.00 0.00 -0.67 -0.67 0.00 0.00 0.00 0.00 -0.67 -0.67 0.00 0.00 0.00 -65 -61 -61 -61 -61 -65 -96 -73 -73 -73 -73 -96 -96 -73 -73 -73 -73 -96 -92 -76 -109 -109 -76 -92 -134 -134 0 0 -134 -134 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -75 -86 -86 -98 0 0 -165 -81 -106 -165 0 0 0 -165 -165 0 0 0 0 -134 -134 0 0 0 0 -134 -134 0 0 0 0 -134 -134 0 0 0 84 78 78 78 78 84 71 67 67 67 67 71 71 67 67 67 67 71 71 67 69 69 67 71 77 75 0 0 75 77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 84 78 78 84 0 0 75 67 67 75 0 0 0 70 70 0 0 0 0 71 71 0 0 0 0 71 71 0 0 0 0 77 77 0 0 0 19 17 17 17 17 19 -25 -6 -6 -6 -6 -25 -25 -6 -6 -6 -6 -25 -21 -9 -40 -40 -9 -21 -58 -59 0 0 -59 -58 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 -8 -8 -14 0 0 -90 -14 -38 -90 0 0 0 -95 -95 0 0 0 0 -63 -63 0 0 0 0 -63 -63 0 0 0 0 -58 -58 0 0 0 7 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs DRAG (0.6 X GCP X QZ X A) (LBS) TOTAL DEAD LOAD (1X DL) (LBS) DRAG CALCULATION MODIFIED GCP FACTOR PER MODULE (UPLIFT EFFECT)UPLIFT FOR DRAG (0.6 X GCP X QZ X A) (LBS) PROJECT REPORT VERSION:INT 10.20.22 9-9-23 2:47 PM DRAG CHECK MODIFIED GCP FACTOR PER MODULE (DRAG EFFECT) Array 1 2 TOTAL DEAD LOAD (1X DL) (LBS) 3557 lbs 2732 lbs Drag + Uplift (0.6 X GCP X QZ X A): 1729 lbs 1570 lbs Total Drag Load: 1729 lbs 1570 lbs Total Dead Load: 3557 lbs 2732 lbs Check if Dead Load>Drag OK OK 204 158 158 158 158 204 119 99 99 99 99 119 119 99 99 99 99 119 119 102 112 112 102 119 149 142 0 0 142 149 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 204 158 158 204 0 0 185 121 121 257 0 0 0 155 155 0 0 0 0 167 167 0 0 0 0 167 167 0 0 0 0 173 173 0 0 0 0.36 0.36 0.36 0.36 0.36 0.36 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.24 0.32 0.32 0.24 0.24 0.32 0.32 0.00 0.00 0.32 0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.48 0.62 0.62 0.62 0.00 0.00 0.43 0.33 0.43 0.43 0.00 0.00 0.00 0.43 0.43 0.00 0.00 0.00 0.00 0.43 0.43 0.00 0.00 0.00 0.00 0.43 0.43 0.00 0.00 0.00 0.00 0.43 0.43 0.00 0.00 0.00 15.3 15.3 15.3 15.3 15.3 15.3 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 10.4 13.6 13.6 10.4 10.4 13.6 13.6 0.0 0.0 13.6 13.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 20.6 26.8 26.8 26.8 0.0 0.0 18.3 14.1 18.3 18.3 0.0 0.0 0.0 18.3 18.3 0.0 0.0 0.0 0.0 18.3 18.3 0.0 0.0 0.0 0.0 18.3 18.3 0.0 0.0 0.0 0.0 18.3 18.3 0.0 0.0 0.0 -0.17 -0.17 -0.17 -0.17 -0.17 -0.17 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.25 -0.32 -0.32 -0.25 -0.25 -0.32 -0.32 0.00 0.00 -0.32 -0.32 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -0.23 -0.29 -0.29 -0.29 0.00 0.00 -0.43 -0.33 -0.43 -0.43 0.00 0.00 0.00 -0.43 -0.43 0.00 0.00 0.00 0.00 -0.43 -0.43 0.00 0.00 0.00 0.00 -0.43 -0.43 0.00 0.00 0.00 0.00 -0.43 -0.43 0.00 0.00 0.00 33.7 33.7 33.7 33.7 33.7 33.7 49.8 49.8 49.8 49.8 49.8 49.8 49.8 49.8 49.8 49.8 49.8 49.8 49.8 49.8 64.8 64.8 49.8 49.8 64.8 64.8 0.0 0.0 64.8 64.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 45.6 59.2 59.2 59.2 0.0 0.0 87.5 67.3 87.5 87.5 0.0 0.0 0.0 87.5 87.5 0.0 0.0 0.0 0.0 87.5 87.5 0.0 0.0 0.0 0.0 87.5 87.5 0.0 0.0 0.0 0.0 87.5 87.5 0.0 0.0 0.0 8 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs Risk Category II ← Table 1.5-1 (ASCE 7-16) Importance Factor, IS 1 ← Table 1.5-2 (ASCE 7-16) Exposure Category B ← Sec on 26.7 (ASCE 7-16) Exposure Factor, Ce 1 ←Table 7.2 (ASCE 7-16) Thermal Factor, Ct 1 ←Sec on C7.8 (ASCE 7-16) Ground Snow, pg 0 psf Tilt Angle 5° Flat Roof Snow Load, pf = 0.7CeCtIspg 0.0 psf '← Equa on 7.3-1 (ASCE 7-16) Minimum Snow Load, pm For pg ≤ 20 psf 0.0 psf ← Sec on 7.3.4 (ASCE 7-16) For pg > 20 psf 20.0 psf ← Sec on 7.3.4 (ASCE 7-16) Slope Factor, Cs 1 ← Figure 7-2a (ASCE 7-16)* Sloped Roof Snow Load, ps = Cspf 0.0 psf ← Equa on 7.4-1 (ASCE 7-16)* 9-9-23 2:47 PM SNOW DESIGN PROJECT REPORT VERSION:INT 10.20.22 SNOW DESIGN *Section C7.8 states "collectors should be designed to sustain a load calculated by using the "unobstructed slippery surfaces" curve in Fig. 7-2a." This indicates that Ct ≤ 1.0. Per Figure 7-2a for a roof slope of 5° with the unobstructed slippery surfaces graph, Cs = 1.0. 9 1605 E 4th St - 101113848 and 20178713 11/15/2023 PROJECT TITLE:Hiner Partners PROJECT ID:QR-20230908-45506 Name:Solar Symphony Construction, Inc.Designed By: SK Address:1605 E 4th St Product: RM5 City, State:Santa Ana, CA 92701, USA 480 Watt Panels Module:Hanwha/Q-Cells Q.Peak Duo XL-G10.2-1349 Sq Ft. 480 Watts 21.1 kWs PROJECT REPORT TOTAL DOWN LOAD PER SECONDARY BAY VERSION:INT 10.20.22 9-9-23 2:47 PM TOTAL DOWN LOAD CALCULATIONS TOTAL DOWN LOAD PER MODULEMODIFIED GCP FACTOR PER MODULE TOTAL DOWN LOAD PER PRIMARY BAY 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 103 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 100 135 133 133 133 135 100 106 177 174 174 174 177 106 107 180 178 178 178 180 107 104 173 172 172 172 173 104 102 170 134 99 134 170 102 68 103 67 0 67 103 68 0 0 0 0 0 0 0 0 0 0 0 0 0 0 109 144 133 144 109 0 0 116 187 174 187 116 0 0 103 176 211 157 83 0 0 0 135 207 135 0 0 0 0 132 201 132 0 0 0 0 134 203 134 0 0 0 0.30 0.30 0.30 0.30 0.30 0.30 0.39 0.39 0.39 0.39 0.39 0.39 0.39 0.39 0.39 0.39 0.39 0.39 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.33 0.00 0.00 0.33 0.33 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.48 0.30 0.30 0.48 0.00 0.00 0.39 0.39 0.39 0.39 0.00 0.00 0.00 0.39 0.39 0.00 0.00 0.00 0.00 0.33 0.33 0.00 0.00 0.00 0.00 0.33 0.33 0.00 0.00 0.00 0.00 0.33 0.33 0.00 0.00 0.00 264 218 218 218 218 264 198 178 178 178 178 198 198 178 178 178 178 198 185 168 178 178 168 185 214 207 0 0 207 214 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 300 218 218 300 0 0 264 200 200 328 0 0 0 234 234 0 0 0 0 233 233 0 0 0 0 233 233 0 0 0 0 238 238 0 0 0 10 1605 E 4th St - 101113848 and 20178713 11/15/2023 10'-1" 11 ' - 3 " 3'-0" 5' - 5 " 14 0 ' - 8 " 69'-5" 14 0 ' - 8 " 69'-5" MD P UM (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION D09/26/2023REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S 1 PLOT PLAN WITH ROOF PLAN SCALE: 3/32" = 1'-0"PV-2 SITE PLAN (E) UTILITY METER (E) DISTRIBUTION PANEL, 400A ROOF ACCESS POINT DR I V E W A Y 48" FIRE SETBACK E 4TH ST EA S T S I D E A V E PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y L I N E PROPERTY LINE 48 " F I R E S E T B A C K 48 " F I R E S E T B A C K 48" FIRE SETBACK DR I V E W A Y ROOF #1 (44) HANWHA Q CELLS Q.PEAK DUO XL-G10.3/BFG MODULES 48" FIRE SETBACK HATCH #1 PV-0.0 1605 E 4th St - 101113848 and 20178713 11/15/2023 4'-11" 44'-0"7'-4" 4' - 9 " 54 ' - 7 " 64 ' - 7 " MD P UM JB INV ACD (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION D09/26/2023REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S PV LAYOUT ROOF MODULE TYPE, DIMENSIONS & WEIGHT NUMBER OF MODULES = 44 MODULES MODULE TYPE = Q.PEAK DUO XL-G10.3/BFG 480 WEIGHT = 64.2 LBS / 29.1 KG. MODULE DIMENSIONS = 87.2"X 41.1" = 24.89 SF ROOF DESCRIPTION ROOF TYPE ROLLED ASPHALT ROOF # OF MODULES MODULE TILT AZIMUTH RAFTER SIZE RAFTER SPACING #1 44 5°180°2"x4"24" O.C. ARRAY AREA & ROOF AREA CALC'S ROOF # OF MODULES ARRAY AREA (Sq. Ft.) ROOF AREA (Sq. Ft.) ROOF AREA COVERED BY ARRAY (%) #1 44 1095.16 6691.83 16 LEGEND CP INV - INVERTER - AC COMBINER PANEL - VENT (ROOF OBSTRUCTION) - CONDUIT ACD - AC DISCONNECT - UTILITY METERUM MDP - DISTRIBUTION PANEL 87 . 2 " 41.1" HANWHA Q CELL Q.PEAK DUO XL-G10.3/BFG 480W MODULES 1.38" 1 PV ROOF LAYOUT SCALE: 3/32" = 1'-0"PV-3 - PV MODULE CONDUIT RUN (ON ROOF) TO INVERTER ROOF ACCESS POINT ROOF #1 (44) HANWHA Q CELLS Q.PEAK DUO XL-G10.3/BFG MODULES UNIRAC BALLESTED RM5 (N) JUNCTION BOX INSIDE BUILDING (E) FRONT OF BUILDING (E) BACK OF BUILDING E 4TH ST (E) UTILITY METER (E) DISTRIBUTION PANEL, 400A (N) AC DISCONNECT, 100A (N) SOLAREDGE SE17.3KUS INVERTER INSIDE BUILDING EA S T S I D E A V E 48" FIRE SETBACK 48 " F I R E S E T B A C K 48 " F I R E S E T B A C K 48" FIRE SETBACK 48" FIRE SETBACK HATCH #1 PV-1.0 1605 E 4th St - 101113848 and 20178713 11/15/2023 MD P UM JB INV ACD (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION D09/26/2023REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S LAYOUT STRING 1 STRING LAYOUT PV-4 SCALE: 3/32" = 1'-0" STRING 1 (E) FRONT OF BUILDING (E) BACK OF BUILDING E 4TH ST EA S T S I D E A V E STRING 2 (44) Q.PEAK DUO XL-G10.3/BFG (480W) MODULES (02) STRINGS OF 22 MODULES CONNECTED IN SERIES PV-2.0 1605 E 4th St - 101113848 and 20178713 11/15/2023 (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS PV-10 HI N E R P A R T N E R S 16 0 5 E 4 T H S T SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT DATA SHEET ATTACHMENT RACKING & 1605 E 4th St - 101113848 and 20178713 11/15/2023 (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS PV-5 HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION D09/26/2023REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S DETAIL ATTACHMENT NTS UNIRAC RMDT BALLAST SYSTEM2 NTS UNIRAC RMDT SYSTEM1 ·THE EXISTING ROOF STRUCTURE HAS BEEN EVALUATED FOR THE PROPOSED NEW SOLAR LOAD AND DETERMINED TO BE OF SUFFICIENT CAPACITY TO INSTALL THE PROPOSED SOLAR ARRAY. NOTE: ARRAY DIMENSIONS WILL VARY BASED ON MODULE WIDTH & LENGTH. PV MODULE RM5 MOUNT PV MODULE RM5 MOUNT 1605 E 4th St - 101113848 and 20178713 11/15/2023 (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS PV-13 HI N E R P A R T N E R S 16 0 5 E 4 T H S T , SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION D09/26/2023REVISION CO N S T R U C T I O N T Y P E : I I I - B OC C U P A N C Y : G R O U P B - B U S I N E S S ARRAY LAYOUTS NOT TO SCALENO R T H LEGEND 2BALLAST BAY WITH BLOCK COUNT SUPPLEMENTARY BALLAST BAY WITH BLOCK COUNT MODULE WITH NORTH DEFLECTOR 2 N ARRAY 1 ARRAY 2 43'-613 16" 21 ' - 9 1 8" 29'-011 16" 25 ' - 9 5 16 " N N N N 1 1 2 2 1 2 2 2 2 2 2 2 2 2 22 1 1 1 1 2 1 2 2 2 2 2 N N N N N N 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 MMMMMM MMMMMM MMMMMM MMMM 2 MMMM MM MM MM MM 14 1 1 B R O A D W A Y B O U L E V A R D N E AL B U Q U E R Q U E , N E W M E X I C O , U S A , 8 7 1 0 2 WW W . U N I R A C . C O M RE V I S I O N S RE V DA T E DE S C R I P T I O N DR W CH K 0 12 / 2 8 / 2 0 2 2 IN I T I A L R E L E A S E PK SS A 09 / 0 9 / 2 0 2 3 RE V I S I O N ( L A Y O U T H A N G E ) SK VK - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SOLAR SYMPHONY CONSTRUCTION, INC. HINER PARTNERS 1605 E 4TH ST SANTA ANA, CA 92701, USA ARRAY LAYOUT RM.300 FOR ENGINEER'S STAMP PROJECT TITLE SHEET KEY PLAN NOT TO SCALE PL A N N O R T H ARRAY 1 ARRAY 2 NOT TO SCALE NO R T H ARRAY 1 ARRAY 2 LEGEND 2 BALLAST BAY WITH BLOCK COUNT SUPPLEMENTARY BALLAST BAY WITH BLOCK COUNT MODULE WITH NORTH DEFLECTOR 2 N 1605 E 4th St - 101113848 and 20178713 11/15/2023 (2 1 . 1 2 0 K W D C ) REV SHEET NAME SHEET NUMBER DATEDESCRIPTION REVISIONS PROJECT NAME & ADDRESS PV-14 HI N E R P A R T N E R S 16 0 5 E 4 T H S T SA N T A A N A , C A 9 2 7 0 1 A11/10/2022FOR REVIEW SIGNATURE & SEAL CONTRACTOR SIGNATURE SOLAR SYMPHONY 1255 STONE DR. SAN MARCOS, CA 92078 PHONE #: (760) 300-4141 EMAIL: ops@solarsymphony.com CSLB LICENSE: 988146 CLASS: C-46 B11/18/2022MODULE LAYOUT C04/19/2023REVISION RM5 DETAILS 1605 E 4th St - 101113848 and 20178713 11/15/2023