Loading...
HomeMy WebLinkAbout1613 E Buffalo Ave - PlanOwner: Alan Van Ho Address: 1613 E Buffalo Ave, Santa Ana, CA 92705 Sheet Item 1-2 Wind parameters 3-4 Seismic parameters and determination of Fp 5 design loads, roof member check, wind uplift check, deflection 6 attachment check, rail span check 7 lateral check Project Number: SMX-10576 Date: BASIS FOR DESIGN CODE: 2022 California Building Code ASCE 7-16 LIVE LOADS ROOF 20.0 psf SNOW 0.0 psf CALCULATIONS FOR SOLAR PHOTOVOLTAIC PANELS: INDEX TO CALCULATIONS Engineering Calculations Performed By: Doug Engineering 5 Via Belmonte, Rancho Santa Margarita, CA 92688 949-285-5104 Engineering Calculations For: Solar Max Renewable Energy Provider, Inc. 3080 12th Street, Riverside, CA 92507 (951) 300-0788 5/16/2023 1613 E Buffalo Ave 07/17/23 FLUSH MOUNTED SOLAR PANELS Type of Roof Gable Roof Slope - = Angle of plane of roof from horizontal, in degrees = 18 deg Mean Roof Height - Eave height will be used for <= 10deg h = 22 ft Building dimensions s1 = 30 ft s2 = 30 ft a = 10% of least horizontal dimension or 0.4h, whichever is smaller, but not less than 4% of the least horizontal direction or 3 ft a = 3 ft B = Horizontal dimension of building normal to wind direction, in ft. B = 20 ft Horizontal dimension of building Attachment Spacing Effective Area A = 12 ft2 p = qh(GCp)( E)( a ) 29.4-7 Velocity pressure Exposure Coefficients ROOF OVERHANG Wind Exposure C (GCp)down =0.52 0.52 Kzt = 1 (GCp)upz1 =-2 -2.5 Kd = 0.85 (GCp)upz2e =-2 -2.5 Kz = 0.85 (GCp)upz2n =-2.89 -3.42 Ke = 1 (GCp)upz2r =-2.89 -3.42 E = 1 (GCp)upz3e =-2.89 -3.95 a = 0.77 (GCp)upz3r =-3.46 -4.51 V = 110 mph qh = 0.00256KzKztKdKeV2 qh = 22.4 psf p = 17.248 *(GCp) FIGURE 30.3-2B Components & Cladding h<= 60 ft: External Pressure Coefficients, (GCp), for Enclosed and Partially Enclosed Buildings - Gable roofs 7<=20deg ASCE 7-16 1 1613 E Buffalo Ave 07/17/23 Wind Pressures Wind Down - All Zones 9 psf 10 psf, MIN ROOF OVERHANG Zone 1 -34.5 psf -43.12 psf Zone 2e -34.5 psf -43.12 psf Zone 2n -49.85 psf -58.99 psf Zone 2r -49.85 psf -58.99 psf Zone 3e -49.85 psf -68.13 psf Zone 3r -59.68 psf -77.79 psf All panels are in Zones 1 and 2e ROOF OVERHANG Use -34.5 psf -43.12 psf 0.6*W -20.7 psf -25.9 psf ASCE 7-16 2 1613 E Buffalo Ave 07/17/23 Soil Site Class = D Risk Category = II SS = 1.462 Mapped Spectral Response acceleration in short periods S1 = 0.537 Mapped Spectral Response acceleration at one second periods SS< 0.25 SS= 1.0 SS>1.25 SS>1.5 0.8 0.8 0.8 0.8 0.9 0.9 1.0 1.0 1.3 1.2 1.2 1.2 1.6 1.1 1.0 1.0 2.4 - - - -- - - Fa =1.200 (interpolated)SMS = Fa*SS = 1.754 Min. 1.2 per 11.4.3 S1< 0.1 S1= 0.4 S1>0.5 S1>0.6 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 1.5 1.5 1.5 1.4 2.4 1.6 1.5 1.7 4.2 - - - -- - - Fv =1.574 (interpolated) SM1 = Fv*S1 = 0.845 SDS = 2/3 *SMS = 1.17 SD1 = 2/3 *SM1 = 0.563 SDS RISK CATEGORY SD1 RISK CATEGORY > I, II III IV > I, II III IV 0 A A A 0 A A A 0.167 B B C 0.067 B B C 0.33 C C D 0.133 C C D 0.5 D D D 0.2 D D D Seismic Design Category = D ASCE 7-16 Table 1613.2.3(1) Values of Site Coefficient Fa F - 1.2 SITE CLASS SS= 0.5 SS= 0.75 A 0.8 0.8 B 1.2 0.9 D 1.4 0.9 0.8 0.8 1.3 Table 1613.2.3(2) 0.8 Values of Site Coefficient Fv S1= 0.2 S1= 0.3SITE CLASS 1.7 A 0.8 1.3 C E - 1.5 1.5 B E - - F - - 2.2 2.0D C 1613 E Buffalo Ave 07/17/23 Seismic Use Group =I Seismic Design Category =D I =1 SS = 1.462 S1 = 0.537 SMS = 1.754 SM1 = 0.845 R = 6.5 Height = 11.375 T = 0.035*hn^.75 = 0.21679 r (Reliability/Redundancy Factor)= 1 SDS = 1.17 SD1 = 0.563 (ASCE 7-16 12.8-2)Cs = SDS/(R/I)= 0.1800 W (ASCE 7-16 12.8-3)Cs <= SD1/[(R/I)T]= 0.400 W (ASCE 7-16 12.8-5)Cs >= .01 = 0.01 W If S1>0.6g (ASCE 7-16 12.8-5)Cs >= 0.5*S1/[R/I]=0.000 W V(controls)=0.1800 W Determine Fp for seismic loading on attachments Seismic Load on Nonstructural Components Spacing of attachments 4 ft Tributary width of attachments = 1/2 Panel length = 37 in Ap = 12.3 ft2 PV unit weight including racking = 3 psf Wp = 37 lb Other mechanical/electrical components ap =1 Fp = 0.4apSDS*Wp/(Rp/Ip)(1+2z/h) 34.63 lb 13.3-1 Rp = 1.5 Ip = 1 Fp <= 1.6SDS*IpWp 69.26 lb 13.3-2 SDS = 1.170 Wp = 37 lb Fp >= 0.3SDS*IpWp 12.99 lb 13.3-3 z= 22 ft h= 22 ft ASCE 7-16 1613 E Buffalo Ave 07/17/23 SHEET: 5 OF 7 DATE: DE JOB NO.: DESIGN LOADS Dead Loads Uplift Roof 0.6WL CONC S TILE 9.0 psf 0.6WL Zone 1 and 2e -20.7 psf, MIN 10 PSF 5/8" Ply shtg 1.9 Overhang -25.9 psf Rf Frm'g 2.8 pWLdown = 9.0 psf 10 psf, MIN 10 PSF Misc. 1.5 Uplift 0.6DL+0.6WL (N) PV System 3.0 Zone 1 0.6*3 -20.7 -18.9 psf Zone 2 0.6*3 -25.9 -24.1 psf Total DL 18.2 psf Downward DL+0.6WL LL 20.0 psf PDL+WL = 13.0 psf SNOW 0.0 psf Rafter Check Existing 2x4 TRUSSES @ 24" o.c Spacing 2.00 ft Trib panel width = 4 ft E 1500000 psi Fb = 900*1.5*1.15 1552.5 psi I 5.4 in^4 MallowWind = 1110 ft-lb Span1 7.00 ft MallowLL = 867 ft-lb Span2 7.00 ft See below for Wind Uplift loads Span3 7.00 ft due to concentated loads at attachments Span4 0.00 ft (Distance to Att. Pts) a b R1 (lb) R2 (lb Load (psf) Trib W (ft) Wind Uplift (lb) Mmax wind(ft- lb) Wind Down (lb) P = PVDL (lb) 4.00 1 4.76 4.76 2.24 81.7 173.6 20.7 4.0 255.3 389 123.33 37.0 160.3 2 8.72 1.72 5.28 192.6 62.7 20.7 4.0 255.3 331 123.33 37.0 160.3 3 10.62 3.62 3.38 123.3 132.0 20.7 4.0 255.3 446 123.33 37.0 160.3 4 14.58 0.58 6.42 234.1 21.2 20.7 4.0 255.3 136 123.33 37.0 160.3 5 16.48 2.48 4.52 164.9 90.4 20.7 4.0 255.3 409 123.33 37.0 160.3 6 20.45 6.45 0.55 20.1 235.2 20.7 4.0 255.3 129 123.33 37.0 160.3 21.40 Span 1 Uniform DL 7.00 63.8 63.8 9.1 psf 2.0 18.2 plf 112 Span 2 Uniform DL 7.00 63.8 63.8 9.1 psf 2.0 18.2 111.7 Reactions at Span1 145.5 237.4 Negative values are uplift reactions Reactions at Span2 298.0 85.0 Mmaxwindup =349 ft-lb < 1110 ft-lb OK Mmaxwinddown =506 ft-lb < 1110 ft-lb OK For DL+LL including the PV system weight point loads w = 70.4 plf P = 37.0 lb Mmax =504 ft-lb < 867 ft-lb OK Deflection Check DDL = 5wL4/(384EI) (5*18.2*7^4)*1728 = 0.245 in = L/ 343.4 OK 384*1.5E6*5.4 PROJECT: CLIENT: BY: PV Panels for Alan Van Ho Solar Max Renewable Energy Provider, In Doug Engineering 5/16/2023 SMX-10576 P = DL+WL (lb) 1613 E Buffalo Ave 07/17/23 SHEET: 6 OF 7 DATE: DE JOB NO.: CHECK SCREW ATTACHMENTS FOR WIND UPLIFT Pwuplift = 255.3 lb 5/16" Lag with min 2.5" penetration for each attachment Table 12.2A - NDS - Lag Screw Withdrawal Values For 5/16" Lag into .5G wood 266 lb Allowable wind load = 1.6*2.5*266 1064 lb > 255.3 lb OK CHECK SCREW ATTACHMENTS FOR SHEAR DUE TO SEISMIC Fp Fp = 34.63 lb Roof slope/module tilt 18 deg Shear = Fp*cos(18 ) = 32.9 lb Fp sin(ang) Tension = Fp*sin(18 ) = 10.7 lb Fp cos(ang) Table 11K - NDS Z =190 lb CD =1.6 ` Z' = Z*CD =304 lb >32.94 lb OK Withdrawal capacity W' = 1064 lb Interaction Equation ft/Ft+fv/Fv 0.25 +0.108 = 0.358 < 1 OK RAIL SPAN CHECK Everest Railing Check Load for half a panel = 2.7' W = 57.78 plf Per the Everest Engineering for 110 mph, 0 psf snow, and 18 deg roof slope, the max span for Crossrail44-X is 72" for Array Interior Panels and 52" for Array Array Edge panels Use Crossrail44-X PV Rails with a spacing of 48" o.c. max for attachment points, typ. 5/16/2023 SMX-10576 PROJECT: CLIENT: BY: PV Panels for Alan Van Ho Solar Max Renewable Energy Provider, Inc. Doug Engineering 1613 E Buffalo Ave 07/17/23 SHEET: 7 OF 7 DATE: DE JOB NO.: LATERAL ANALYSIS DETERMINE ADDITIONAL LOAD COMPARED TO EXISTING FOR LATERAL LOADING Aroofexisting= = 2400 sf Wpanel = 48.5 lb Wroofexisting = 15.2*2400 = 36480 lb 21 *Wpanel = 1018.5 lb Wwallexisting = 15*80*4 = 4800 lb Wrestofarray = 310.8 lb Wexisting = 41280 lb Warray = 1329.3 lb V = 0.18 W Vroofexisting = 7430 lb Existing Total Lateral Force Vroofwpanels = 7670 lb New Total Later Force % increase = 7670 increase which results in less than a 10% increase in the 7430 stress of existing lateral resisting elements OK*100%-100% = 3% BY: Doug Engineering SMX-10576 PROJECT: PV Panels for Alan Van Ho CLIENT: Solar Max Renewable Energy Provider, Inc.5/16/2023 1613 E Buffalo Ave 07/17/23 1613 E Buffalo Ave 07/17/23 REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: CS-01DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder AERIAL MAP VICINITY MAP HOUSE VIEW COVER SHEET ALAN VAN HO - 8.505kW DC, 6.090kW AC, 7.665kW CEC AC RATING APPLICABLE CODES ·ELECTRIC CODE:CEC 2022 ·FIRE CODE:CFC 2022 ·BUILDING CODE:CBC 2022 ·RESIDENTIAL CODE:CRC 2022 SYSTEM SIZE: MODULES: INVERTER: 8505W DC, 6090W AC, 7665W CEC AC RATING SCOPE OF WORK (21)HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) (21)ENPHASE IQ8PLUS-72-2-US (240V)(SI-1) BRANCH DETAILS: 1X11, 1X10 ENPHASE BRANCHES SHEET CATALOG SHEET REVISION DESCRIPTION CS-01 B COVER SHEET CS-02 B GENERAL NOTES E-01 B SITE PLAN S-01 B MOUNTING DETAILS S-02 B STRUCTURAL DETAILS E-02 B SINGLE LINE DIAGRAM E-03 B ELECTRICAL CALCULATIONS E-03.1 B EQUIPMENT ELEVATION VIEW PL-01 B PLACARDS SS B SPEC SHEET(S) 1. MODULES ARE LISTED UNDER UL 61730 AND CONFORM TO THE STANDARDS. 2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6. ALL CONDUCTORS SHALL BE 600V, 90°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING GENERAL NOTES RISK CATEGORY- ll BASIC WIND SPEED = 95 MPH @ 3-SEC GUST GROUND SNOW LOAD = 0 PSF DESIGN CRITERIA PROJECT WINDSPEED DETERMINED USING THE ASCE 7 STANDARD UNLESS DIRECTED OTHERWISE BY LOCAL JURISDICTION AMENDMENTS ROOF AREA CALCULATION TOTAL ARRAY AREA = 443.54 sq.ft TOTAL ROOF AREA = 2400 sq.ft % ARRAY AREA IN ROOF = 18.48 % Bldg# 101115785 Elec# 20180258 Issued 07/13/23 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 1613 E Buffalo Ave 07/17/23 REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: CS-02DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder GENERAL NOTES INSTALLATION NOTES: 1. STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTOR WHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. 2. ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. 3. LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. 4. ALL PV RACKING ATTACHMENTS SHALL BE STACKED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. 5. ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6. ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 7/8" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7. THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. 8. ALL SOLAR PANEL ARRAY COMPONENTS SHALL BE INSTALLED PER THE MANUFACTURER'S APPROVED INSTALLATION SPECIFICATIONS. 9. THE EXISTING BUILDINGS STRUCTURE SHALL BE VERIFIED AS PROPERLY CONSTRUCTED AND MAINTAINED IN GOOD CONDITION. NO ALLOWANCE HAS BEEN MADE IN THESE DRAWINGS FOR ANY EXISTING DEFICIENCY IN DESIGN, MATERIAL, CONSTRUCTION, OR LACK OF MAINTENANCE FOR THE EXISTING STRUCTURE OR PROPOSED EQUIPMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS, PROPER FIT, AND CLEARANCES IN THE FIELD. 10. WATERPROOFING AROUND THE ROOF PENETRATIONS IS THE RESPONSIBILITY OF OTHERS. 11. MISCELLANEOUS ITEMS NOT EXPLICITLY LISTED OR IDENTIFIED IN THESE DRAWINGS HAVE NOT BEEN DESIGNED. IT IS RECOMMENDED THAT MATERIAL OF SUITABLE SIZE STRENGTH TO BE OBTAINED FROM A REPUTABLE MANUFACTURER FOR MISCELLANEOUS ITEMS. 12. IF PROJECT IS STAMPED AND SEALED BY AN ILLUMINE-I STRUCTURAL ENGINEER, SEE ASSOCIATED ILLUMINE-I STRUCTURAL REPORT FOR FULL COMPREHENSIVE SCOPE OF STRUCTURAL ENGINEERING INVESTIGATION AND APPROVAL. 13. IF ANY CONDITION THROUGHOUT THE ASSOCIATED REPORT OR PERMIT DRAWINGS IS NOT ALSO REPRESENTED ON-SITE, CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES AND RECEIVE WRITTEN APPROVAL FROM THE ENGINEER OF RECORD BEFORE PROCEEDING WITH INSTALLATION. 14. CONTRACTOR TO PROVIDE MINIMUM 1/4" GAP BETWEEN ALL SOLAR PANELS. ROOF ACCESS PATHWAYS AND SETBACKS: 1205.2.1 SOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3 BUILDINGS SOLAR PHOTOVOLTAIC (PV) SYSTEMS FOR GROUP R-3 BUILDINGS SHALL COMPLY WITH SECTIONS  1205.2.1.1 THROUGH 1205.2.3. EXCEPTIONS: 1. THESE REQUIREMENTS SHALL NOT APPLY TO STRUCTURES DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH THE CALIFORNIA RESIDENTIAL CODE. 2. THESE REQUIREMENTS SHALL NOT APPLY TO ROOFS WITH SLOPES OF 2 UNITS VERTICAL IN 12 UNITS HORIZONTAL (16.7-PERCENT SLOPE) OR LESS. 1205.2.1.1 PATHWAYS TO RIDGE NOT FEWER THAN TWO 36-INCH-WIDE (914 MM) PATHWAYS ON SEPARATE ROOF PLANES, FROM LOWEST ROOF EDGE TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. NOT FEWER THAN ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLANE WITH A PHOTOVOLTAIC ARRAY, NOT FEWER THAN ONE 36-INCH-WIDE (914 MM) PATHWAY FROM LOWEST ROOF EDGE TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PHOTOVOLTAIC ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. 1205.2.1.2 SETBACKS AT RIDGE FOR PHOTOVOLTAIC ARRAYS OCCUPYING 33 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. FOR PHOTOVOLTAIC ARRAYS  OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 1205.2.1.3 ALTERNATIVE SETBACKS AT RIDGE WHERE AN AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITHIN THE DWELLING IN ACCORDANCE WITH SECTION 903.3.1.3, SETBACKS AT THE RIDGE SHALL CONFORM TO ONE OF THE FOLLOWING: 1. FOR PHOTOVOLTAIC ARRAYS OCCUPYING 66 PERCENT OR LESS OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 18 INCHES (457 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 2. FOR PHOTOVOLTAIC ARRAYS OCCUPYING MORE THAN 66 PERCENT OF THE PLAN VIEW TOTAL ROOF AREA, A SETBACK OF NOT LESS THAN 36 INCHES (914 MM) WIDE IS REQUIRED ON BOTH SIDES OF A HORIZONTAL RIDGE. 1205.2.2 EMERGENCY ESCAPE AND RESCUE OPENINGS: PANELS AND MODULES INSTALLED ON GROUP R-3 BUILDINGS SHALL NOT BE PLACED ON THE PORTION OF A ROOF THAT IS BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. A PATHWAY OF NOT LESS THAN 36 INCHES (914 MM) WIDE SHALL BE PROVIDED TO THE EMERGENCY ESCAPE AND RESCUE OPENING. 1613 E Buffalo Ave 07/17/23 MSP AC CB A A A AA A A A AB B B B B B B B B B A A (E) UTLITY METER WITH MAIN SERVICE PANEL(EXTERIOR) (N) AC DISCONNECT SWITCH (EXTERIOR) (N) ENPHASE IQ COMBINER 4C (INTERIOR) FENCE CONDUIT RUN PROPERTY LINE PHOTOVOLTAIC ARRAY ON THE ROOF GATE 1'-6" FIRE SETBACK 3' FIRE SETBACK DR I V E WA Y SCALE:1/16" = 1'-0" REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: E-01DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder SITE PLAN ALAN VAN HO - 8.505kW DC, 6.090kW AC, 7.665kW CEC AC RATING PERIMETER FENCE PATIO E BUFFALO AVE WA L K WA Y WALK WAY 80' 84'-10" 94'-2" 25'-10" 8'-9" 5'-8" 3'-6" STRING CONFIGURATION BRANCH DETAILS A 11 MODULES B 10 MODULES TOTAL AREA OF ROOF (SQ.FT) 2400 TOTAL ARRAY AREA (SQ.FT)443.54 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%)18.48 SYSTEM SIZE: MODULES: INVERTER: 8505W DC, 6090W AC, 7665W CEC AC RATING SCOPE OF WORK (21)HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) (21)ENPHASE IQ8PLUS-72-2-US (240V)(SI-1) BRANCH DETAILS: 1X11, 1X10 ENPHASE BRANCHES 1613 E Buffalo Ave 07/17/23 A A A AA A A A AB B B BB B B B B B A A ALUMINIUM RAILS 2 X 4 PRE-FABRICATED TRUSSES @ 2'-0"SPACING ARRAY MP-01 SCALE:1"=10'-0" MOUNTING DETAILS REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: S-01DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. HolderMP-03 270° 18° 4 84.48 CURVED S TILE K2 UNIVERSAL STANDARD HOOK ATTIC PRE-FABRICATED TRUSSES 2'-0"2 X 4 4'-0" 1'-6" S.NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.) ROOF EXPOSURE FRAME SPACING MAX RAIL SPANROOF TYPE ATTACHMENT FRAME TYPE MP-01 360° 18° 5 105.6 CURVED S TILE K2 UNIVERSAL STANDARD HOOK ATTIC PRE-FABRICATED TRUSSES 2'-0" OVER HANG FRAME SIZE 2 X 4 MP-02 180° 18° 12 253.45 CURVED S TILE K2 UNIVERSAL STANDARD HOOK ATTIC PRE-FABRICATED TRUSSES 2'-0"2 X 4 4'-0" 1'-6" 4'-0" 1'-6" SITE INFORMATION NOTE:PENETRATIONS ARE STACKED STRING CONFIGURATION BRANCH DETAILS A 11 MODULES B 10 MODULES TOTAL AREA OF ROOF (SQ.FT) 2400 TOTAL ARRAY AREA (SQ.FT)443.54 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%)18.48 NOTE:TOTAL NO. OF ATTACHMENT=50 ARRAY MP-02 ARRAY MP-03 3' 1'-6" 1'-6" 3' 3'1'-6" 1'-6" 3' 3' 1'-6" 1'-6" 3'1'-6" 1'-6"3' 1'-6" 1'-6" 4' 1613 E Buffalo Ave 07/17/23 REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: S-02DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder STRUCTURAL DETAILS MODULE END CLAMP MID CLAMPMODULE DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 21 48.5 1018.5 MID-CLAMP 22 0.3 6.6 END-CLAMP 40 0.31 12.4 RAIL LENGTH 155 0.47 72.85 SPLICE BAR 2 0.65 1.3 K2 UNIVERSAL STANDARD HOOK 54 1.01 54.54 MICRO-INVERTER 21 2.38 49.98 TOTAL WEIGHT OF THE SYSTEM (LBS)1211.49 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)443.54 WEIGHT PER SQ. FT.(LBS)2.75 WEIGHT PER PENETRATION (LBS)24.23 ATTACHMENT DETAIL-K2 UNIVERSAL STANDARD HOOK SCALE:NTS MODULE K2 CROSSRAIL 6" MAX (E) ROOF DECKING (E) TILE ROOF (E) FRAMING SEE SHEET S-01 STAINLESS STEEL 5/16" LAG SCREW2.5" EMBEDMENT PILOT HOLE REQUIRED 5/16 HEX-BOLT K2 UNIVERSAL STANDARD HOOK ROOF FRAMING DETAILS CURVED S TILE ROOF 2 X 4 PRE-FABRICATED TRUSSES @2'-0"SPACING MODULE LOAD BEARING WALL SCALE:NTS 5/16" X 3.5" LAG SCREW 2 BOLT PER PENETRATION MID-CLAMP AND END-CLAMP ASSEMBLY MODULE DATA HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) MODULE DIM 74"x41.1"x1.26" LAG SCREW 5/16"x3.5":2.5" MIN EMBEDMENT MID CLAMP ASSEMBLY MODULE FRAME K2 CROSSRAIL 44-X GROUNDING MID-CLAMP SCALE: NTS K2 CROSSRAIL 44-X K2 STRUCTURAL RAIL CONNECTOR T-BOLT SCREW SCALE: NTS MODULE TO MODULE & MODULE TO RAIL T-BOLT SCALE: NTS GROUNDING LUG GROUNDING DETAILS RAIL TO RAIL 1613 E Buffalo Ave 07/17/23 3 3 (N)60A AC DISCONNECT SQUARE D DU222RB AC DISCONNECT NON FUSED 60A, 120/240V, 2P 20A 15A 20A ENPHASE IQ COMBINER BOX X-IQ-AM1-240-4/4C,120/240V NEMA 3R INSTALL (2)20A PV 2P BREAKERS,(1)15A 2P BREAKER FOR MONITORING INSTALLED BY FACTORY (N)ENPHASE IQ COMBINER 4/4C (ONLY FOR SOLAR, NO LOADS TO BE ADDED) (11)HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (405W), MODULES WITH (11)ENPHASE IQ8PLUS-72-2-US (240V)(SI-1) (1) BRANCH OF (11) MICRO-INVERTERS (N)JUNCTION BOX 1 DC CONDUCTORS AC CONDUCTORS (1) BRANCH OF (10) MICRO-INVERTERS (10)HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) MODULES WITH (10)ENPHASE IQ8PLUS-72-2-US (240V)(SI-1) 1 DC CONDUCTORS AC CONDUCTORS 2 MICRO-INVERTERS MICRO-INVERTERS (E)225A END FED MAIN PANEL UTILITY GRID (E ) 2 0 0 A M A I N BR E A K E R PV BREAKER AT THE OPPOSITE END OF BUSBAR (E) GROUND ELECTRODE (N)40A 2P PV BREAKER EXISTING 120/240V 1PH 60HZ METER#:SCE-SOUTHERN CALIFORNIA EDISON 222014-213266M REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: E-02DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder SINGLE LINE DIAGRAM DC SYSTEM SIZE- 8505W, AC SYSTEM SIZE - 6090W, CEC AC RATING - 7665W 1 2 3 NOTE: EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 6 AWG BARE COPPER 2 3/4"EMT (4) 10 AWG THHN/THWN-2 NONE (1) 6 AWG THHN/THWN-2 3 3/4"EMT (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 CONDUCTOR AND CONDUIT SCHEDULE 1613 E Buffalo Ave 07/17/23 REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: E-03DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder ELECTRICAL NOTES ELECTRICAL CALCULATIONS DC SYSTEM SIZE- 8505W, AC SYSTEM SIZE - 6090W, CEC AC RATING - 7665W ENPHASE IQ8PLUS-72-2-US (240V)(SI-1) MICRO INVERTER SPECIFICATIONS MODEL POWER RATING 290W MAX OUTPUT CURRENT 1.21A CEC WEIGHTED EFFICIENCY 97% MAX NO OF MICRO INVERTERS/BRANCH 13 MAX DC VOLTAGE 60V 10.83 AMAX POWER CURRENT:Imp 11.17 ASHORT CIRCUIT CURRENT:Isc 37.39 VMAX POWER VOLTAGE:Vmp 45.34 VOPEN CIRCUIT VOLTAGE:Voc 405 WMODULE POWER @ STC MODEL MODULE SPECIFICATION HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ 405 (405W) OCPD CALCULATION ALLOWABLE BACKFEED: MAIN PANEL RATING = 225 A MAIN BREAKER RATING = 200 A 120% RULE: = ((MAIN PANEL RATING * 1.2) - MAIN BREAKER RATING) = ((225 A*1.2)-200 A) = 70 A ALLOWABLE BACKFEED = 70 A INVERTER OVERCURRENT PROTECTION: INVERTER OVERCURRENT PROTECTION = (MICROINVERTER O/P CURRENT * # OF MICROINVERTER * CONTINUOUS LOAD(1.25)) = (1.21 * 21 *1.25) = 31.76 A PV BREAKER = 40 A ≥ 31.76 A ALLOWABLE BACKFEED 70 A ≥ 40 A OF PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(3)(2) REQUIREMENTS. TAG 1: (AC) REQUIRED CONDUCTOR AMPACITY(1.21 x 11 x 1.25) CORRECTED AMPACITY CALCULATION(0.87 x 1 x 30) 16.64 A < 26.1 A TAG 2: (AC) REQUIRED CONDUCTOR AMPACITY(1.21 x 11 x 1.25) CORRECTED AMPACITY CALCULATION(0.87 x 0.8 x 40) 16.64 A < 27.84 A TAG 3: (AC) REQUIRED CONDUCTOR AMPACITY(1.21 x 21 x1.25) CORRECTED AMPACITY CALCULATION(0.87 x 1 x 55) 31.76 A < 47.85 A = 16.64 A = 26.1 A = 16.64 A = 27.84 A = 31.76 A = 47.85 A WIRE SIZE CALCULATIONS AC WIRE SIZING CALCULATIONS BASED ON FOLLOWING EQUATIONS REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT * #OF INVERTERS = MAX CURRENT PER 690.8(A)(1)(e)* 125% = MAX CURRENT PER 690.8(B)(1) CORRECTED AMPACITY CALCULATIONS: DERATED CONDUCTOR AMPACITY PER 690.8(B)(2) = AMPACITY * TEMPERATURE DERATE FACTOR * CONDUIT FILL DERATE DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(1) < DERATED CONDUCTOR AMPACITY 1. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.10(D). 2. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.10(C). 3. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4. ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5. BREAKER/FUSE SIZES PER CEC 240. 6. AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER CEC 250.122. 7. THE AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 690.31(A). 8. THE AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON CEC 310.15(B)(1). 9. MAX SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. 10. CONDUCTORS ARE SIZED PER CEC TABLE 310.16. 1613 E Buffalo Ave 07/17/23 UTILITY GRID (E)SINGLE PHASE SERVICE M (E)MAIN SERVICE PANEL (N) ENPHASE IQ COMBINER 4C BACKYARD STREET (N)UTILITY AC DISCO (N)J-BOX AC C O N D UI T WINDOW (INTERIOR) (EXTERIOR) (EXTERIOR) G GATE REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: E-03.1DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder EQUIPMENT ELEVATION VIEW EQUIPMENT ELEVATION VIEW 1613 E Buffalo Ave 07/17/23 MS P AC CB REV: B AHJ: CA-CITY OF SANTA ANA 33.766955, -117.844651 APN: 396-05-604 NAME: ALAN VAN HO DRAFTED BY: ARUNDEEPAN R ADDRESS: 1613 E BUFFALO AVE, SANTA ANA, CA 92705 UTILITY: SCE-SOUTHERN CALIFORNIA EDISON SCALE: AS NOTED PRN NUMBER: SMT-76199 PAPER SIZE: 17"X11"SHEET: PL-01DATE: 04/29/2023 DRAWING INFORMATION CUSTOMER INFORMATION CONTRACTOR INFORMATION QC'ED BY: SURYA PRAKASH P SOLARMAX RENEWABLE ENERGY PROVIDER INC. 3080 12TH ST, RIVERSIDE, CA 92507 TEL: (951) 300-0788 LICENSE NUMBER& CLASS:972048/C-46 David Bingwen Hsu David Bingwen Hsu, Lic. Holder 1613 E BUFFALO AVE, SANTA ANA, CA 92705 PLACARDS INSTALLED ON: DC DISCONNECT, INVERTER [TO BE USED WHEN INVERTER IS UNGROUNDED] ! WARNING! ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED INSTALLED ON: AC DISCONNECT, POINT OF INTERCONNECTION APPLICABLE CODE(S): CEC 690.13 ! WARNING! ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALSON TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING-ELECTRIC SHOCK HAZARD NO USER SERVICEABLE PARTS INSIDE CONTACT AUTHORIZED SERVICE PROVIDE FOR ASSISTANCE INSTALLED ON: INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT SOLAR DISCONNECT INSTALLED ON: DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC690.13(B) SYSTEM UTILIZES MICRO-INVERTERS LOCATED UNDER EACH SOLAR MODULE ! WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM INSTALLED ON: POINT OF INTERCONNECTION APPLICABLE CODE(S): CEC 705.12(B)(3-4) AND 690.59 !! INSTALLED ON: POINT OF INTERCONNECTION APPLICABLE CODE(S): CEC 705.12(B)(3)(2) WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE INSTALLED ON: AC DISCONNECT(S), POINT OF INTERCONNECTION. APPLICABLE CODE(S): CEC 690.54 RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 25.41 240 PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH AMPS AC VAC POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN 1.PLACARDS SHALL MEET THE REQUIREMENTS OF ARTICLES 690 AND 705, UNLESS OTHERWISE SPECIFIED PER LOCAL AHJ REQUIREMENTS. 2.PLACARDS SHALL MEET THE REQUIREMENTS OF SECTION 110.21(B) AS REQUIRED AND SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCT SAFETY SIGNS AND LABELS. 3.PLACARDS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD. 4.PLACARDS SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED AND SHALL BE HANDWRITTEN. 5.PLACARDS SHALL NOT COVER EXISTING MANUFACTURER LABELS. NOTES CAUTION:MULTIPLE SOURCES OF POWER !! LABEL LOCATION SERVICE PANEL PER CODE: CEC 705.10 TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN INSTALLED ON: WITHIN 3 FT OF SERVICE DISCONNECTING MEANS. MIN 3/8" BLACK TEXT ON YELLOW BACKGROUND & 3/16" BLACK TEXT ON WHITE BACKGROUND. APPLICABLE CODE(S): CEC 690.56(C) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM INSTALLED ON:RAPID SHUTDOWN SWITCH APPLICABLE CODE(S): CEC 690.56(C)(2) DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL NO LOAD SHALL BE ADDED TO THIS PANEL (E) UTLITY METER WITH MAIN SERVICE PANEL(EXTERIOR) (N) AC DISCONNECT SWITCH(EXTERIOR) (N) ENPHASE IQ COMBINER 4C(INTERIOR) PHOTOVOLTAIC ARRAY ON THE ROOF 1613 E Buffalo Ave 07/17/23 MODULE SPEC SHEET 1613 E Buffalo Ave 07/17/23 INVERTER SPEC SHEET 1613 E Buffalo Ave 07/17/23 AC DISCONNECT SPEC SHEET 1613 E Buffalo Ave 07/17/23 COMBINER SPEC SHEET 1613 E Buffalo Ave 07/17/23 ATTACHMENTS AND RACKING SPEC SHEET 1613 E Buffalo Ave 07/17/23 ATTACHMENTS AND RACKING SPEC SHEET 1613 E Buffalo Ave 07/17/23 ENGINEERING LETTER 1613 E Buffalo Ave 07/17/23 ENGINEERING LETTER K2 Systems 2835 La Mirada Dr, Suite A Vista, CA 92081 TEL: (760) 301-5300 Attn.: Everest Solar - Engineering DepartmentRe: Report # 20-02753vHG.02 – K2 Systems CrossRail - 44-X Dual Rail System for Gable and Hip Roofs Subject: Engineering Certification for the State of California Building Codes: 1. ASCE/SEI 7-16, Minimum Design Loads for Buildings and Other Structures, by American Society of Civil Engineers 2. 2022 California Building Code, by California Building Standards Commission 3. 2021 International Building Code, by International Code Council, Inc. 4. 2021 International Residential Code, by International Code Council, Inc. 5. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES 6. Aluminum Design Manual 2020, by The Aluminum Association, Inc. 7. ANSI/AWC NDS-2018, National Design Specification for Wood Construction, by the American Wood Council Design Criteria: Risk Category II Seismic Design Category = A - E Exposure Category = B, C & D Basic Wind Speed (ultimate) per ASCE 7-16 = 95 mph to 200 mph Ground Snow Load = 0 to 100 (psf) This letter certifies that the loading criteria and design basis for the K2 Systems CrossRail Span Tables are in compliance with the above codes. If you have any questions on the above, do not hesitate to call. October 7, 2021 PZSE, Inc. – Structural Engineers has provided engineering and span tables for the K2 Systems CrossRail, as presented in PZSE Report # 20-02753vHG.02, "Engineering Certification for the K2 Systems CrossRail - Dual Rail System for Hip and Gable Roofs". All information, data, and analysis therein are based on, and comply with, the following building codes and typical specifications: REENI IGER LARUTCURTS AINROFILACFOETAST G EN LANOISSEFORP E DRETS EHCAZHTENEKL N AP Exp. 3-31-25 No. S3878 R U DIGITALLY SIGNED Prepared by: PZSE, Inc. – Structural Engineers Roseville, CA 1613 E Buffalo Ave 07/17/23 MODULE CERTIFICATION 1613 E Buffalo Ave 07/17/23 1613 E Buffalo Ave 07/17/23 1613 E Buffalo Ave 07/17/23 1613 E Buffalo Ave 07/17/23 1613 E Buffalo Ave 07/17/23 1613 E Buffalo Ave 07/17/23 Rev: 2/17/2015 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2013 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall fill in the address of the project, contractor’s licensing information and answer questions 1 -10 below. Complete and sign the certification section. **If answering NO to any of the questions, plan check shall be required.** Project Address: ________________________________________________________________ Contractor Company Name: _______________________________________________________ Contractor License Number: _______________________________________________________ YES NO Are the following applicable to the proposed project? 1.Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 2.Will the PV system weigh maximum 3 pounds per square feet or less? 3.Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 4.Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 5.Will the PV system be installed without using any ballast system or counter-weight system? 6.Will the PV system be installed on a roof having only one roofing layer with no overlays? 7.Will the PV system layout provide a three-foot wide clear access pathway per the latest edition of “Guideline for Fire Safety Elements of Solar Photovoltaic Systems” by OCFA? (Guideline available on the OCFA website: http://www.ocfa.org) 8.Do the plans show a maximum horizontal anchor spacing of 6 feet? 9.Do the plans show a minimum of 2-1/2 inch lag screw embedment into roof rafters? 10.Are ALL the structural pages of the plans WET stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print name: ________________________________ Signature: _________________________ Phone Number: _____________________________Date: _____________________________ Email Address: _________________________________________________________________ Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1613 E Buffalo Ave 07/17/23