HomeMy WebLinkAbout1740 E Edinger Ave - PlanDATEDRAWN JOB NUMBER:24-0740 PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L.07-16-24 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 SYMBOL MIN. OSA CFM SUPPLY FAN FAN (BHP) TOTAL COOLING (MBH) SENSIBLE COOLING (MBH) COOLING POWER (VOLT/PH/HZ) TOTAL OPERATING WEIGHT (LBS)NOTESREFRIGERANTCFMMODEL FILTER (QUANTITY) SIZE TYPE EXT. SP IN. WG MOCPMANUFACTURER HEATING CAPACITY (MBH) HEATING NOMINAL TONS MCA OSA AMBIENT TEMP. ƒ)DRIVE ARI EER IEER (SEER) REFERENCE NOTES: HEATING EFFICIENCY (%) 1 9/27/24 PLAN CHECK CORRECTIONS BLDG permit #101120530 APPROVALS: PLNG - H. Jacinto POLICE - B. Martin BLDG - J. Lo MECH #40139427 APPROVALS: MECH - T. Luka 1740 E Edinger Ave 11/27/2024 345 Pollasky Ave. ∙ Clovis, California 93612 ∙ 559-696-6511 STRUCTURAL ENGINEERING CALCULATIONS (PC RESPONSE) IHOP #955 1740 EAST EDINGER AVENUE SANTA ANA, CA PROJECT# 24297 October 21, 2024 Prepared For: NUWAVE Energy Solutions 1740 E Edinger Ave 11/27/2024 IHOP 955 Santa Ana, CA STRUCTURAL PC RESPONSE: X: Structural calculations for the new equipment anchorage is not found. Please provide... Response: See attached calculation package for the HVAC anchorage. Structural plans with HVAC anchorage have also been created. Please see the added structural sheets S1.1, and S2.1. __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave. Clovis, California, 93612 (559) 323-9600 (559) 323-9633 Fax ____________________________________________________ Copyright 2024 Brad Young & Associates Print Date: 10/21/2024 File Name: 24297 - PC RESPONSE.xmcd Engineer:_ CG _ 1 1740 E Edinger Ave 11/27/2024 ATTACHED CALCULATION PACKAGE __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave. Clovis, California, 93612 (559) 323-9600 (559) 323-9633 Fax ____________________________________________________ Copyright 2024 Brad Young & Associates Print Date: 10/21/2024 File Name: 24297 - PC RESPONSE.xmcd Engineer:_ CG _ 2 1740 E Edinger Ave 11/27/2024 HVAC ANCHORAGE Check the HVAC anchorage. Check worst case, which will be RTU 4 Lateral Loading on HVACs Seismic Loads S DS 1.02:= Seismic Design Category - D Per table 13.6-1 HVAC component amplification factorap2.5:= Per table 13.6-1 HVAC Component Response modification factor Rp 6.0:= z 14 ft⋅:=HVAC roof attachment height h 14 ft⋅:=estimated roof height Ip 1.0:=Importance Factor HVAC weight (including curb adapter and roof curb)W p 2340lb:= Horizontal Seismic Force: Fp.seis Fp.1 0.4 ap⋅S DS⋅W p⋅ R p Ip     1 2 z h ⋅+   ⋅:=Fp.1 1193 lb= Fp.max 1.6 SDS⋅Ip⋅W p⋅:=Fp.max 3819 lb= Fp.min 0.3 S DS⋅Ip⋅W p⋅:=Fp.min 716 lb= Fp.seis max min Fp.1 Fp.max, ()Fp.min, ():=Fp.seis 1193 lb= Vertical Seismic Force: Fv.seis Fv.seis 0.2 S DS⋅W p⋅:=Fv.seis 477 lb= __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave. Clovis, California, 93612 (559) 323-9600 (559) 323-9633 Fax ____________________________________________________ Copyright 2024 Brad Young & Associates Print Date: 10/21/2024 File Name: 24297 - PC RESPONSE.xmcd Engineer:_ CG _ 3 1740 E Edinger Ave 11/27/2024 Lateral Analysis - Wind Analysis per ASCE 7-16 section 29.4.1 Exposure C Risk Category II K e 1.0:=V 95:=K zt 1.0:= K z 0.85:=K d 0.90:= qz 0.00256 Kz⋅Kzt⋅K d⋅Ke⋅V2⋅psf⋅:=qz 17.675 psf⋅= h 14 ft=roof height Lhvac 100 in⋅:=length of HVAC W hvac 66 in⋅:=width of HVAC Hhvac 60 in⋅12 in⋅+14in+:=height of HVAC unit, curb, & adapter as it occurs Lcurb 98 in⋅4 in⋅−:=Lcurb 94 in⋅=approx. length to roof curb anchor W curb 62 in⋅4 in⋅−:=W curb 58 in⋅=approx. width to roof curb anchor Horizontal Wind Force: Fh.wind A f H hvac Lhvac⋅:=A f 60 ft2=Projected area normal to the wind GCr.h 1.9:=Gust effect factor Fh.wind qz GCr.h⋅Af⋅:=Fh.wind 2006 lb=Lateral wind load Vertical Wind Force: Fv.wind A r Lhvac W hvac⋅:=A r 46 ft2=Projected area normal to the wind GCr.v 1.5:=Gust effect factor Fv.wind qz GCr.v⋅Ar⋅:=Fv.wind 1215 lb=Vertical wind load (Upward) Lateral Analysis - Summary 0.6 Fh.wind⋅1203 lb=Max factored lateral wind load Wind Governs 0.7 Fp.seis⋅835 lb=Max factored lateral seismic load __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave. Clovis, California, 93612 (559) 323-9600 (559) 323-9633 Fax ____________________________________________________ Copyright 2024 Brad Young & Associates Print Date: 10/21/2024 File Name: 24297 - PC RESPONSE.xmcd Engineer:_ CG _ 4 1740 E Edinger Ave 11/27/2024 Check HVAC Unit Overturning - Transverse Direction Lhvac 8.333 ft=length of HVAC W hvac 5.5 ft=width of HVAC Hhvac 7.167 ft=height of HVAC W p 2340 lb=weight of HVAC Unit OTM1 0.6 Fh.wind⋅( ) Hhvac 2 ⋅:=OTM1 4312 lb ft⋅= RM W p W curb 2 ⋅:=RM 5655 lb ft⋅= Uplift 1 1 2 OTM1 0.6( ) RM⋅− W curb ⋅ 1 4 0.6 Fv.wind( )⋅⋅+ ...277.336 lb=:=uplift at each corner Check HVAC Unit for Overturning - Longitudinal Direction Lhvac 8.333 ft=length of HVAC W hvac 5.5 ft=width of HVAC Hhvac 7.167 ft=height of HVAC W p 2340 lb=weight of HVAC Unit OTM2 0.6 Fh.wind⋅( ) Hhvac 2 ⋅:=OTM2 4312 lb ft⋅= RM W p Lcurb 2 ⋅:=RM 9165 lb ft⋅= Uplift 2 1 2 OTM2 0.6( ) RM⋅− Lcurb ⋅ 1 4 0.60 Fv.wind( )⋅⋅+ ...106.502 lb=:=uplift at each corner Maximum Uplift Uplift max Uplift1 Uplift2, 0, ():=Uplift 277 lb= Anchorage required to resist uplift loads __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave. Clovis, California, 93612 (559) 323-9600 (559) 323-9633 Fax ____________________________________________________ Copyright 2024 Brad Young & Associates Print Date: 10/21/2024 File Name: 24297 - PC RESPONSE.xmcd Engineer:_ CG _ 5 1740 E Edinger Ave 11/27/2024 Connection between existing roof curb and new curb adapter Connection between new curb adapter and new HVAC unit is similar. Uplift 277 lb=(ASD - wind load) Tek Screws Six (6) #12x1" Tek screws connect a 16 ga. strap to a 16 ga. roof curb and six (6) more Tek screws connect the same 16 ga. strap to the steel HVAC unit rail. These Tek screws resist uplift in shear at each corner. Shear capacity of Tek screws - #12x1" (aka 12-14 per ICC ESR-1976)Shearcapacity.tek 308 lb⋅:= Nscrew 6:=Number of screws Nscrew Shearcapacity.tek⋅ Uplift 6.663=> 1.0 GOOD There will also be these same strap clips w/ screws at the midspan of the unit that will be used to resist the shear forces from the unit (4 min). V unit.ASD 0.6 Fh.wind⋅( )1203.343 lb=:= Nclips 4:=Number of clips resisting shear Nscrew 6= Nscrew Nclips⋅Shearcapacity.tek⋅ Vunit.ASD 6.143=> 1.0 GOOD __________________________ BRAD YOUNG & ASSOCIATES STRUCTURAL ENGINEERING 345 Pollasky Ave. Clovis, California, 93612 (559) 323-9600 (559) 323-9633 Fax ____________________________________________________ Copyright 2024 Brad Young & Associates Print Date: 10/21/2024 File Name: 24297 - PC RESPONSE.xmcd Engineer:_ CG _ 6 1740 E Edinger Ave 11/27/2024 W S T R U C T U R A L E N G I N E E R I N G BR A D Y O U N G & A S S O C I A T E S , I N C . 34 5 P O L L A S K Y A V E . CL O V I S , C A L I F O R N I A 9 3 6 1 2 PH O N E : ( 5 5 9 ) 3 2 3 - 9 6 0 0 F A X : ( 5 5 9 ) 3 2 3 - 9 6 3 3 pr o j e c t dr a w i n g BY A p r o j e c t da t e de s i g n e d dr a w n ch e c k e d sheet ma r k re v i s i o n s da t e de s c r i p t i o n 1 2 3 4 5 by BY A J O B # 2 4 2 9 7 SA N T A A N A , C A . 9 2 7 0 5 CW 10 / 2 2 / 2 4 CI T Y C O M M E N T S ST O R E # 9 5 5 17 4 0 E . E D I N G E R A V E . 24 2 9 7 BY A CW 1740 E Edinger Ave 11/27/2024 S T R U C T U R A L E N G I N E E R I N G BR A D Y O U N G & A S S O C I A T E S , I N C . 34 5 P O L L A S K Y A V E . CL O V I S , C A L I F O R N I A 9 3 6 1 2 PH O N E : ( 5 5 9 ) 3 2 3 - 9 6 0 0 F A X : ( 5 5 9 ) 3 2 3 - 9 6 3 3 pr o j e c t dr a w i n g BY A p r o j e c t da t e de s i g n e d dr a w n ch e c k e d sheet ma r k re v i s i o n s da t e de s c r i p t i o n 1 2 3 4 5 by BY A J O B # 2 4 2 9 7 SA N T A A N A , C A . 9 2 7 0 5 CW 10 / 2 2 / 2 4 CI T Y C O M M E N T S ST O R E # 9 5 5 17 4 0 E . E D I N G E R A V E . 24 2 9 7 BY A CW 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1 9/27/24 PLAN CHECK CORRECTIONS 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1 9/27/24 PLAN CHECK CORRECTIONS 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY:E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 9/ 2 7 / 2 0 2 4 3 : 4 1 : 3 9 P M IH O P # 9 5 5 I H 17 4 0 E A S T E D I N G E R A V E . SA N T A A N A , C A 9 2 7 0 5 12 2 0 N o r t h B a r s t e n W a y An a h e i m , C A 9 2 8 0 6 71 4 . 6 3 2 . 7 4 0 1 | Co n t r a c t o r L i c . # : 6 0 9 9 6 7 ww w . d i v e r s i f i e d t h e r m a l s e r v i c e s . c o m 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY:E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1 9/27/24 PLAN CHECK CORRECTIONS 9/ 2 7 / 2 0 2 4 3 : 4 1 : 4 2 P M 12 2 0 N o r t h B a r s t e n W a y An a h e i m , C A 9 2 8 0 6 71 4 . 6 3 2 . 7 4 0 1 | Co n t r a c t o r L i c . # : 6 0 9 9 6 7 ww w . d i v e r s i f i e d t h e r m a l s e r v i c e s . c o m IH O P # 9 5 5 I H 17 4 0 E A S T E D I N G E R A V E . SA N T A A N A , C A 9 2 7 0 5 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY:E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 9/ 2 7 / 2 0 2 4 3 : 4 1 : 4 7 P M 12 2 0 N o r t h B a r s t e n W a y An a h e i m , C A 9 2 8 0 6 71 4 . 6 3 2 . 7 4 0 1 | Co n t r a c t o r L i c . # : 6 0 9 9 6 7 ww w . d i v e r s i f i e d t h e r m a l s e r v i c e s . c o m IH O P # 9 5 5 I H 17 4 0 E A S T E D I N G E R A V E . SA N T A A N A , C A 9 2 7 0 5 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY:E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 9/ 2 7 / 2 0 2 4 3 : 4 1 : 5 2 P M 12 2 0 N o r t h B a r s t e n W a y An a h e i m , C A 9 2 8 0 6 71 4 . 6 3 2 . 7 4 0 1 | Co n t r a c t o r L i c . # : 6 0 9 9 6 7 ww w . d i v e r s i f i e d t h e r m a l s e r v i c e s . c o m IH O P # 9 5 5 I H 17 4 0 E A S T E D I N G E R A V E . SA N T A A N A , C A 9 2 7 0 5 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 1 9/27/24 PLAN CHECK CORRECTIONS 1740 E Edinger Ave 11/27/2024 DATEDRAWN JOB NUMBER: PROJECT TITLE : DRAWING NUMBER : DRAWING NAME : PROJECT ADDRESS: BY: 1220 NORTH BARSTEN WAY ANAHEIM, CA 92806 PHONE:714-632-7401 FAX:714-632-7402 E.L. 1740 EAST EDINGER AVE. SANTA ANA,CA 92705 24-0740 07-16-24 REFERENCE NOTES: 1 9/27/24 PLAN CHECK CORRECTIONS 1740 E Edinger Ave 11/27/2024 YES NO INSTRUCTIONS: ORAN GE COUNTY FI RE AUTHORI TY Plan Submittal Criteria COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects and RESIDENTIAL TRACT developments · Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place. · Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section. · If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA. · In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations. · Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602. Address Suite City Project Scope/Business Description 1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within 300 feet of an active or proposed oil well? Fire Master Plan (PR145) 2. Property is adjacent to a wildland area or non-irrigated native vegetation? Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124) 3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170) 4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475) 5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000 sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285) 6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card, button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520) 7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment; industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations? Special Equipment Plan (PR315, PR340-PR382) 8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240) 9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330) 10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335) Initial each of the following two items indicating that you have read and understand the statement: 11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications. 12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327— Initials the building department will determine specific requirements. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name Signature Phone Number ( ) Date / / Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the appropriate plans and fees for OCFA review. 10-08-14 EE COM 1740 E Edinger Ave 11/27/2024 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Referral Form Required for OCFA to review plans upon the request of the Building Department when the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”. City / County Official Requesting Review: City / County Reference #: Date: __________________________________ City / County: _____________________________________ E-Mail: __________________________________ Contact Name: _____________________________________ Phone #: _________________________________ Title: _____________________________________ ** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. ** Reason(s) for Review: Please describe why OCFA Plan Review is or may be required by the City/County : OCFA COMMENTS:  No further action required on this specific plan type, based on information provided on: ____/______/______.  Project to be taken in for OCFA Review. Other: Name: _________________________________________ Contact #: ______________________________________ Date: _________________________________ OCFA Authorization Updated: 06/02/2020 rs 1740 E Edinger Ave 11/27/2024