My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1805 S Garnsey St - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Garnsey St
>
1805 S Garnsey St
>
1805 S Garnsey St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:59:53 AM
Creation date
6/1/2025 11:59:44 AM
Metadata
Fields
Template:
Plan
Permit Number
20182076
101118229
Full Address
1805 S Garnsey St
Document Relationships
101118229 - Permit
(Permit - Plan)
Path:
\Building\Permits\G\Garnsey St\1805 S Garnsey St
20182076 - Permit
(Permit - Plan)
Path:
\Building\Permits\G\Garnsey St\1805 S Garnsey St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
COVER SHEET <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />1805 S GARNSEY ST, SANTA ANA, CA, 92707 USA <br />SHEET NAME <br />SHEET NUMBER <br />PV-0 <br />PROJECT NAME <br />RI <br />C <br />A <br />R <br />D <br />O <br /> <br />T <br />O <br />R <br />R <br />E <br />S <br />18 <br />0 <br />5 <br /> <br />S <br /> <br />G <br />A <br />R <br />N <br />S <br />E <br />Y <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br /> <br />U <br />S <br />A <br />AP <br />N <br /># <br /> <br />0 <br />1 <br />3 <br />2 <br />4 <br />2 <br />0 <br />7 <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />C <br />E <br />AH <br />J <br />: <br /> <br />C <br />I <br />T <br />Y <br /> <br />O <br />F <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />DEL MAR, CA 92014, USA <br />REVDATEDESCRIPTION <br />VERSION <br />UR10/13/2022INITIAL RELEASE <br />A01/19/2024REVISION <br />GOVERNING CODES: <br />2 VICINITY MAP <br />SCALE: NTSPV-0 <br />1 AERIAL PHOTO <br />SCALE: NTSPV-0 <br />GENERAL NOTES <br />x THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING <br />ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE <br />CONSTRUCTION PHASE. JOB SAFETY AND CONSTRUCTION PROCEDURES <br />ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. <br />x REFER TO ELECTRICAL DRAWING PV-4 FOR PANEL DETAILED <br />INFORMATION. <br />x IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND <br />ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL <br />GOVERN. <br />x THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING <br />INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND <br />NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATIONS <br />OF PV SYSTEM. <br />x THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING <br />OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF <br />THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE <br />CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER <br />PRIOR TO PERFORMING THE WORK. <br />x ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE <br />WITH ALL APPLICABLE TOWN, COUNTY & STATE REGULATIONS AND/OR <br />ANY OTHER GOVERNING BODIES. <br />x DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST <br />CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR <br />TO INSTALLATION. IF THERE IS A DISCREPANCY IT IS <br />CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER <br />IMMEDIATELY. <br />x LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS <br />OVER OPENINGS SUCH AS DOORS OR WINDOWS. <br />x LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN <br />LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH <br />OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. <br />x DISCONNECT MEANS MUST HAVE DEDICATED CLEAR UNOBSTRUCTED <br />WORKING SPACE NOT LESS THAN 3' DEEP BY 2.5' WIDE TO NOT LESS <br />THAN 6.5' ABOVE WALKABLE SURFACES IN FRONT OF DISTRIBUTION <br />PANEL. <br />x ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS TO BE <br />BONDED. <br />x PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF. <br />x RAPID SHUTDOWN IS ACTIVED AT THE INVERTER BY THE AC DISCONNECT. <br />ELECTRICAL NOTES <br />x ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR <br />ITS APPLICATION. <br />x ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 & 75 <br />DEGREE C WET ENVIRONMENT. <br />x WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE <br />ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE <br />NEAREST RIDGE, HIP, OR VALLEY. <br />x WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL <br />EQUIPMENT SHALL COMPLY WITH CEC 110.26. <br />x DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. <br />CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, <br />FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND <br />STANDARDS. <br />x WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT <br />SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />x ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND <br />READILY VISIBLE. <br />x MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME <br />AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP <br />MANUFACTURER'S INSTRUCTION. <br />x MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER E.G.C. <br />VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />x THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE <br />INTERCONNECTION METHOD : BACKFEED BREAKER <br />SYSTEM SUMMARY: <br />(N) 14 - HANWHA Q CELLS Q.PEAK DUO BLK ML-G10+ (400W) MODULES <br />(N) 14 - ENPHASE ENERGY IQ8A-72-2-US MICRO-INVERTERS <br />(N) JUNCTION BOX <br />(E) 200A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER <br />(N) ENPHASE IQ COMBINER BOX 4 <br />X2-IQ-AM1-240-4 (IEEE 1547:2018) <br />ROOF TYPE: - ASPHALT SHINGLES <br />NUMBER OF LAYERS: - 01 <br />ROOF FRAME: - 2"X6" RAFTERS @24" O.C. <br />STORY: - ONE STORY <br />SNOW LOAD : - 0 PSF <br />WIND SPEED :- 95 MPH <br />WIND EXPOSURE:- C <br />RISK CATEGORY:- II <br />COORDINATE:- 33.724058, -117.874525 <br />ATTACHMENT MOUNT:- RAFTERS MOUNT <br />DESIGN CRITERIA: <br />14 MODULES-ROOF MOUNTED - 5.600 kWDC, 5.114 CEC kWAC <br />SHEET INDEX <br />PV-0 COVER SHEET <br />PV-1 SITE PLAN WITH ROOF PLAN <br />PV-2 ROOF PLAN WITH MODULES <br />PV-3 ATTACHMENT DETAILS <br />PV-4 ELECTRICAL LINE DIAGRAM WITH <br />CALCULATION <br />PV-5 WARNING LABELS & PLACARD <br />PV-6+ EQUIPMENT SPEC SHEETS <br />A <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />2022 CALIFORNIA RESIDENTIAL CODE (CRC) <br />2022 CALIFORNIA EXISTING BUILDING CODE (CEBC) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />2022 CALIFORNIA GREEN BUILDING CODE (CGBC) <br />2022 CALIFORNIA ENERGY CODE (CEC) <br />2022 CALIFORNIA FIRE CODE TITLE 24 SUPPLEMENT <br />ANY OTHER LOCAL AMENDMENTS <br />A <br />6/30/2024 <br />67$03(' <br />CSLB 1060243 C10LB 1 24 <br />1805 S Garnsey St <br />2/9/2024
The URL can be used to link to this page
Your browser does not support the video tag.