HomeMy WebLinkAbout2006 N Deodar St - PlanGENERAL NOTES AERIAL VIEW SHEET INDEX PV1 Cover Page PV2 Property Plan PV3 Site Plan PV4 Mounting Detail PV5 Electrical Diagram PV6 Electrical Calcs PV7 Labels PV8 Placard Cutsheets APPLICABLE CODES:DESCRIPTION OF DESIGN: INSTALLATION OF GRID TIED, UTILITY INTERACTIVE PHOTOVOLTAIC SYSTEM. EQUIPMENT: DC SYSTEM SIZE: KW BIPV Shingle (PV Module): AC SYSTEM SIZE: KW Inverter: ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV C KW (DC) KW (AC)Delta M4-TL-US PV1 GAF Energy Timberline Solar ES (46W)COVER PAGE BY: ZDucatt (56) (1) 1. INSTALLATION OF SOLAR PHOTOVOLTAIC SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 690, AND ALL OTHER APPLICABLE NEC CODES WHERE NOTED OR EXISTING. 2. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110. 3. ALL WIRES, INCLUDING THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE IN ACCORDANCE WITH NEC ARTICLE 250 4. THE BIPV SHINGLES (PV MODULES) ARE CONSIDERED NON-COMBUSTIBLE; THIS SYSTEM IS UTILITY INTERACTIVE PER UL 1741 AND DOES NOT INCLUDE STORAGE BATTERIES OR OTHER ALTERNATIVE STORAGE SOURCES. 5. ALL DC WIRES SHALL BE SIZED ACCORDING TO [NEC 690.8] 6. DC CONDUCTORS SHALL BE WITHIN PROTECTED RACEWAYS IN ACCORDANCE WITH [NEC 690.31] 7. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL JURISDICTIONAL BUILDING CODE. Santa Ana CA 92705 2006 Deodar Street 973-628-3411 125 Mitchell Blvd, Suite D B #1062345 C-10 San Rafael CA 94903 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA FIRE CODE (CFC) Ronald Shepherd GAF Energy LLC (CA)2.576 4 2.576 4 (56) (1) 1/22/2024 GAF Energy Timberline Solar ES (46W) Delta M4-TL-US TOTAL ROOF AREA: 2759.21 sq ft AREA OF PV MODULES: 176.38 sq ft % OF ROOF COVERED: 6.39% PROJECT WILL INCLUDE THE COMPLETE REMOVAL OF THE EXISTING ASPHAT ROOF & UNDERLAYMENT Bldg# 101118000 Elec# 20181911 APPROVALS: PLNG - FArias BLDG - JLo ELEC - MSmith The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Pitch:/12 Azimuth:° Energy Shingle Part Number:TLS-1 ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV C KW (DC)KW (AC)Delta M4-TL-US PV3 GAF Energy Timberline Solar ES (46W)SITE PLAN BY:ZDucatt 4 270 1/22/2024 Ronald Shepherd GAF Energy LLC (CA)2.576 973-628-3411 125 Mitchell Blvd, Suite D2006 Deodar Street (56) 4 (1) B #1062345 C-10 San Rafael CA 94903Santa Ana CA 92705 UTILITY METERM INV MSP AC LC J-BOX BAT PV MAIN SERVICE PANEL LOAD CENTER AC DISCONNECT METER SOCKET (FOR UTILITY PV METER) INVERTER JUNCTION BOX BATTERY(IES) FIRE ACCESS PATHWAY (3' TYP.) EQUIPMENT LEGEND MP#1 MP#2 MP#3 MP#4 ↑ NORTH MP#5 Pass TOTAL ROOF AREA: 2759.21 sq ft AREA OF PV MODULES: 176.38 sq ft %OF ROOF COVERED: 6.39% FRONT OF HOME MP#1 MSP M INV 7.0 ft 8.8 ft3.5 ft 20 . 0 f t 10 . 0 f t 2006 N Deodar St - 101118000 & 20181911 6/11/2024 ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV C KW (DC) KW (AC) Delta M4-TL-US PV4 GAF Energy Timberline Solar ES (46W)MOUNTING DETAIL BY: ZDucatt 2006 Deodar Street (56) 1/22/2024 Ronald Shepherd GAF Energy LLC (CA)2.576 973-628-3411 125 Mitchell Blvd, Suite D 4 (1) Santa Ana CA 92705 B #1062345 C-10 San Rafael CA 94903 INSTALLATION NOTES MINIMUM SHEATHING THICKNESS: 7/16" OSB or 15/32" PLYWOOD. FULL TEAR OFF REQUIRED PRIOR TO INSTALLATION TO VERIFY DECKING THICKNESS, CONDITION, AND CODE-COMPLIANT ATTACHMENT TO STRUCTURE. PLEASE SEE ATTACHED STAMPED STRUCTURAL ENGINEERING LETTER FOR ADDITIONAL EXPLANATION REGARDING PE REVIEW/ REQUIREMENTS FOR THE TIMBERLINE SOLAR PRODU CT. BIPV SHINGLES (PV MODULES) TOP VIEW (NOT TO SCALE) BIPV SHINGLES (PV MODULES) SIDE VIEW (NOT TO SCALE)NOTE: Please see attached Stamped Structural Engineering letter for additional explanation regarding PE review/ requirements for the Timberline Solar product. Compliance Report # 105171274LAX-001a 1 - 1/4" NAILS WILL BE USED TO SECURE SOLAR SHINGLE Plan check NOTES: See highlights for Key Specs. MAS (19) 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Max. Ambient Temperature (degF):PV Module Power (W): DC System Summary INVERTER INV 1 INV 2 INV 3 MPPT 1 2 3 4 1 2 3 4 1 2 3 4 QTY OF MODULES IN SERIES STRING VMP (V) STRING VOC (V) STRING IMP (A) STRING ISC (A) COMBINED STRING IMP (A) COMBINED STRING ISC (A) STRING REFERENCE LETTER ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV A KW (DC)KW (AC)Delta M4-TL-US PV5 GAF Energy Timberline Solar ES (46W)ELECTRICAL CALCS BY:ZDucattB #1062345 C-10 94903 2006 Deodar Street 973-628-3411 125 Mitchell Blvd, Suite D Santa Ana CA 92705 San Rafael CA (56) 9/27/2023 Ronald Shepherd NONE 2.576 4 (1) 4691.4 211.25 28 5.16 325.04 5.40 10.32 A , B 10.80 2006 N Deodar St - 101118000 & 20181911 6/11/2024 ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV A KW (DC)KW (AC)Delta M4-TL-US PV6 GAF Energy Timberline Solar ES (46W)LABELS BY:ZDucattB #1062345 C-10 San Rafael CA 94903Santa Ana CA 92705 9/27/2023 Ronald Shepherd NONE 2.576 (56)125 Mitchell Blvd, Suite D2006 Deodar Street 973-628-3411 4 (1) LABEL 1 AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND DEVICE WHERE ENERGIZED UNGROUNDED CONDUCTORS MAY BE EXPOSED DURING SERVICE. NEC. 690.35(F) LABEL 2 FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION.NEC 690.17(E), NEC 705.22 LABEL 3 AT POINT OF INTERCONNECTION, MARKED AT AC DISCONNECTING MEANS.NEC 690.54, NEC 690.13 (B) LABEL 4 AT POINT OF INTERCONNECTION FOR EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES, EACHSERVICE EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION SOURCE LOCATIONS.NEC 705.12(D)(3 LABEL 6 PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO BUSBAR.NEC 705.12(D)(2)(3)(B) LABEL 7 SIGN LOCATED AT UTILITY SERVICE EQUIPMENT.NEC 690.56(C) LABEL 8 SIGN LOCATED AT PV COMBINER PANEL. NEC 705.12(B)(2)(3)(C) 240 16 LABELING NOTES: 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND MAKE APPROPRIATE ADJUSTMENTS. 2. LABELING REQUIREMENTS BASED ON THE (NFPA 70) 2017 National Electric Code 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED [NEC 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] LABEL 5 AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE TRAYS, COVERS AND ENCLOSURES OF JUNCTION BOXES, AND OTHER WIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS.NEC 690.31(G)(3&4) LABEL 9 -INVERTER AT PV DISCONNECTING MEANS. TO BE USED IF NEC 2014 APPLIES. NEC 690.53 LABEL 10 -INVERTER 1 AT PV DISCONNECTING MEANS. TO BE USED IF NEC 2017 APPLIES. NEC 690.53 325.0 5.40 380 5.16 325. 5.40 LABEL 12 SIGN LOCATED AT INVERTER RAPID SHUTDOWN SWITCH. NEC 690.56(C)(2) LABEL 11 FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY AND CONDUCTORS LEAVING THE ARRAY NEC 690.56(C)(1). CEC 690.56(C)(1)(A) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM INVERTER 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Wire Schedule BIPV Shingle (PV Module) REF QTY Wire Size / Type QTY Wire Size / Type Conduit Notes QTY Make/Model Max output Power 1 (2)AWG PV WIRE, USE-2 COPPER N/A (OR CODE APPROVED EQUIVALENT)GAF Energy Timberline Solar ES (46W)46W 2 (2)AWG THWN-2 (POS, NEG)(1)AWG THWN-2 (GND)EMT (OR CODE APPROVED EQUIVALENT)Rapid Shutdown Device 3A (3)AWG THWN-2 (L1,L2,N)(1)AWG THWN-2 (GND)EMT (OR CODE APPROVED EQUIVALENT)QTY Make/Model Max Output 3B Delta GPI00010105 20A 3C Inverter(s) 4 REF Make/Model AC Voltage Ground Rated Power Max Output Current 5 INV1 Delta M4-TL-US 240V No 6 INV2 7 INV3 8 Energy Shingle Part Number:TLS-1 ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV A KW (DC)KW (AC)Delta M4-TL-US GAF Energy Timberline Solar ES (46W)ELECTRICAL DIAGRAM BY:ZDucatt 4000W 16.0A 4 (1) 92705 B #1062345 C-10 San Rafael CA (56) Santa Ana CA 3/4in 3/4in#10 #10#10 #10 PV4 #12 9/27/2023 (56) 94903 Ronald Shepherd NONE (1) 2.576 2006 Deodar Street 973-628-3411 125 Mitchell Blvd, Suite D GROUNDING & GENERAL NOTES (CONT'D) 5.TRANSITION BOX QUANTITIES, AND PLACEMENT SUBJECT TO CHANGE IN THE FIELD - TRANSITION BOXES DEPICTED ON ELECTRICAL DIAGRAM REPRESENT WIRE TYPE TRANSITIONS. 6.AC DISCONNECT NOTED IN EQUIPMENT SCHEDULE OPTIONAL IF OTHER AC DISCONNECTING MEANS IS LOCATED WITHIN 10' OF SERVICE DISCONNECT. 7.CONDUIT CARRYING THE DC WIRES ARE BONDED AT THE INVERTER. 8. INVERTERS ARE UL 1741 COMPLIANT. INTERCONNECTION NOTES 1. GROUND FAULT PROTECTION IN ACCORDANCE WITH [NEC 215.9] & [NEC 230.95] 2. SUPPLY SIDE INTERCONNECTION ACCORDING TO[NEC 2014, 2017 -705.12(A), NEC 2020, 2023 -705.11] WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH [NEC 240.21(B)] DISCONNECT NOTES 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS) 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH GROUNDING & GENERAL NOTES TIMBERLINE SOLAR USES BIPV SHINGLES (PV MODULES) THAT ATTACH DIRECTLY TO THE ROOF DECKING LIKE ORDINARY ASPHALT SHINGLES.THE BIPV SHINGLES HAVE NO METAL FRAME AND ARE NOT RACK MOUNTED.THE SYSTEM HAS NO EXPOSED, CONDUCTIVE METAL AND REQUIRES NO EQUIPMENT GROUND CONDUCTOR (EGC) FOR THE BIPV SHINGLES, WIRE COVERS OR TRANSITION BOX.THE EGC PATH BEGINS AT THE CONNECTION OF THE CONDUIT (EMT OR FMC, TYPICALLY) AT THE TRANSITION BOX OR PASS THROUGH DEVICE AND TERMINATES AT THE MAIN SERVICE PANEL. TIMBERLINE SOLAR AS A SYSTEM HAS BEEN LISTED TO MEET THE RAPID SHUTDOWN REQUIREMENTS OF ARTICLE 690.12 IN THE 2020, 2017 AND 2014 NEC (ANSI/NFPA 70).ANY LOSS OF CONNECTION TO THE UTILITY GRID WILL TRIGGER RAPID SHUTDOWN OF THE DELTA MCI AND/OR DELTA RSS PV RAPID SHUTDOWN EQUIPMENT (PVRSE) LISTED TO ANSI UL 1741 AND AS A PV HAZARD CONTROL SYSTEM (PVHCS) LISTED TO ANSI/CAN/UL 3741. 1.A SECOND FACILITY GROUNDING ELECTRODE IS NOT REQUIRED PER [NEC 690.47(C)(3)] 2.PV INVERTER IS UNGROUNDED, TRANSFORMER-LESS TYPE. 3.DC AND AC EGC TO REMAIN UNSPLICED, OR SPLICED TO EXISTING ELECTRODE 4.ANY EXISTING WIRING INVOLVED WITH PV SYSTEM CONNECTION THAT IS FOUND TO BE INADEQUATE PER CODE SHALL BE CORRECTED PRIOR TO FINAL INSPECTION. MAIN SERVICE PANEL (E)200 A BUSBAR (E)200 A MAIN BREAKER 200 A/2P(E)20 A/2P(N) string(s)of2 28 INV1 3A 2006 N Deodar St - 101118000 & 20181911 6/11/2024 ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV A KW (DC)KW (AC)Delta M4-TL-US GAF Energy Timberline Solar ES (46W)PLACARD BY:ZDucattSanta Ana CA 92705 9/27/2023 Ronald Shepherd NONE 2.576 2006 Deodar Street San Rafael CA 94903 PV74(1) B #1062345 C-10 CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM ROOF MOUNTED SOLAR ARRAYS WITH SAFETY DISCONNECTS SHOWN: 2006 Deodar Street, Santa Ana CA 92705 (56)973-628-3411 125 Mitchell Blvd, Suite D TOTAL ROOF AREA: 2759.21 sq ft AREA OF PV MODULES: 176.38 sq ft %OF ROOF COVERED: 6.39% FRONT OF HOME MP#1 MSP M INV PV ARRAY INVERTER & RAPID SHUTDOWN DC DISCONNECT SWITCH MAIN DISTRIBUTION UTILITY DISCONNECT 2006 N Deodar St - 101118000 & 20181911 6/11/2024 GAF ENERGY LLC LETTER REPORT SCOPE OF WORK Verification of UL 3741 Approved Components Prepared for Intertek Building and Construction Department for Addition to the CCRR Report REPORT NUMBER 105171274LAX-001a ISSUE DATE 9/14/22 PAGES 3 DOCUMENT CONTROL NUMBER GFT-OP-10a (21-June-2019) © 2019 INTERTEK 2006 N Deodar St - 101118000 & 20181911 6/11/2024 LETTER REPORT 25800 Commercentre Drive Lake Forest, CA 92630 USA Telephone: (949) 448-4100 Facsimile: (949) 448-4111 www.intertek.com This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Version: 21-June-2019 Page 2 of 5 GFT-OP-10a 9/14/22 Report No. 105171274LAX-001a Intertek Project No. G105171274 Frank Lee Ph: (650) 704-8761 5981 Optical Court San Jose, CA 95138 USA frank.lee@gaf.energy SUBJECT: Verification of UL 3741 Approved Components Prepared for Intertek Building and Construction Department for Addition to the CCRR Report Dear Frank Lee, This letter report represents the results of the evaluation of the above referenced product(s) and documentation to the requirements contained in the following standards: UL 3741, UL Standard for Safety for Photovoltaic Hazard Control- First Edition, Dated December 8, 2020 SECTION 1 SUMMARY This investigation was authorized by the quote # Qu-01293515-0 dated August 15, 2022. The scope and intention of this project was the verification of UL 3741 approved components per existing listing report of 104710014LAX-001 for inclusion to the CCRR report only and does not represent authorization for the use of any Intertek certification marks. At the conclusion of the evaluation, the following below table is summarized. Please refer to section 2 of this letter report for more details. 2006 N Deodar St - 101118000 & 20181911 6/11/2024 LETTER REPORT GAF ENERGY LLC Intertek Report: 105171274LAX-001a Version: 21-June-2019 Page 3 of 5 GFT-OP-10a SECTION 2 EVALUATION TO UL 3741 Please see below table for the approved list of PVHCS (sub-assembly not included) Timberline Solar, in combination with the Delta Electronics components and components that are listed under the user manual revision of Rev 2.1 has been evaluated as a system to the requirements in ANSI/CAN UL 3741 Photovoltaic Hazard Control. When installed in accordance with manufacturer’s installation instructions and this report, this system meets the requirements of Article 690.12 of the National Electrical Code for 2014, 2017 and 2020. The terms to describe this function vary slightly in each code cycle: 2014A: “Rapid Shutdown” (RSD) 2017B: “PV Rapid Shutdown Array” (PVRSA) 2020C “PV Hazard Control System” (PVHCS) PV Hazard Control System (PVHCS) Components (sub-assemblies not included) Component & Function Manufacturer Model No. Certification/Standards Years of Compliance to 690.12 Rapid Shutdown System (Mid Circuit Interrupters (MCI)) Delta Electronics GPI00010117, GPI00010119 UL 1741 PVRSE 2014, 2017, 2020 Rapid Shutdown System (Smart RSS) Delta Electronics GPI00010105 D UL 1741 PVRSE 2014, 2017, 2020 Inverters Delta Electronics M8-TL-US, M6-TL- US, M5-TL-US, M4- TL-US, M10-TL-US UL 1741 2014, 2017, 2020 PV Shingle Module (Solar Shingle) GAF Energy 294000328 D UL 61730 & UL 7103 2014, 2017, 2020 TLS-1 D UL 61730 & UL 7103 Wire Cover GAF Energy 294000204 D Tested in end-product within UL 3741 & UL 7103 2014, 2017, 2020 Top Flashing Assembly GAF Energy 294000300 D Tested in end-product within UL 3741 & UL 7103 2014, 2017, 2020 Transition Box GAF Energy 294000257 D Tested in end-product within UL 3741 & UL 7103 2014, 2017, 2020 Pass Through Device GAF Energy 294000200 D Tested in end-product within UL 3741 & UL 7103 2014, 2017, 2020 Jumper Module GAF Energy 294000215 D UL 7103 and evaluated 2014, 2017, 2006 N Deodar St - 101118000 & 20181911 6/11/2024 LETTER REPORT GAF ENERGY LLC Intertek Report: 105171274LAX-001a Version: 21-June-2019 Page 4 of 5 GFT-OP-10a 294000417 D 294000456 D in end-product within UL 3741 2020 A Rapid Shutdown (RSD): Conductors leaving the array must drop to 30V or less within 10 seconds of rapid shutdown initiation. Equipment must be listed, but standards are not specified. 2014 NEC 690.12(2) and (5) B PV Rapid Shutdown Array (PVRSA): A listed assembly or system designed to “reduce but not eliminate risk of electric shock hazard within a damaged PV array during fire-fighting procedures.” 2017 NEC 690.12(B)(2)(1) C PV Hazard Control System (PVHCS): Equipment or multiple pieces of equipment listed to UL 3741 “to reduce the risk of electric shock hazard within a damaged PV array for fire fighters.” 2020 NEC 690.12(B)(2)(1) D As part of a listed PV Hazard Control System Note: A, B and C taken from NEC. Please refer to the NEC for more details INSTALLATION REQUIREMENTS Max System Voltage 600VDC Max Array Internal Voltage After Actuation 600VDC (cold weather VOC) MCI/RSS Voltage Output after Actuation ≤30VDC Voltage Bleed-Down Interval ≤30 secs. Max Series-Connected Solar Shingles per (1) MCI or (1) RSS 48 OTHER INSTALLATION INSTRUCTIONS REDOMMENDED BY GAF INSTALLATION MANUAL REVISION Applicable for Integrated Rooftop Solar for Composition Shingle Steep Sloped Roofs, Installed Using "Timberline Solar Roofing System by GAF Energy LLC, Rev 2.1" 1. MCI or RSS shall be secured inside the Transition Box using provided fasteners. 2. One MCI or RSS must be connected to each series string (48 solar shingles max) or separate mounting plane subarray string. MCI and RSS may be installed on subarrays smaller than 48 series- connected solar shingles. For the most current specifications, instructions and limitations on the use of Delta Electronics components, please refer to their website at https://www.deltaww.com/en-US/ [deltaww.com] index 3. To operate, the MCI requires an Input Operating Voltage of 6 – 80VDC and a Startup Voltage of 22VDC. The Solar Shingles have a VOC of 10.9 VDC. Minimum recommended number of Solar Shingles to the input of each MCI is (6) Solar Shingles 4. Verification that each MCI or RSS is installed with 48 or fewer modules shall be documented for inspection by as-built string diagrams and/or voltage measurement logs. Voltage output per string not to exceed 600V. 5. The RSS has a metal enclosure and shall be bonded to the EGC using the lay-in lug and M4 bolt provided, or by equivalent means approved in the NEC. 6. A designated PV system disconnect shall serve as the RSD/PVRSA/PVHCS initiator and shall be sized, installed, and labeled in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. The inverters evaluated with this system is equipped with an integrated disconnect. 2006 N Deodar St - 101118000 & 20181911 6/11/2024 LETTER REPORT GAF ENERGY LLC Intertek Report: 105171274LAX-001a Version: 21-June-2019 Page 5 of 5 GFT-OP-10a Report number used for this verification are as follow, 104736078LAX-001: UL 61730 104983160LAX-001: UL 7103 E520385: UL 7103/UL 61730 SECTION 3 PROJECT STATUS & ACTION Issuance of this letter report provides summary and status of evaluation of the supporting documentation covered by Intertek Project No. G105171274. If there are any questions regarding the results contained in this report, or any of the other services offered by Intertek, please do not hesitate to contact your dedicated Intertek Project Manager. Completed by: Faraz Ebneali Reviewed by: Samantha Doshi Title: Engineer Title: Reviewer Signature: Signature Date 9/14/22 Date: 9/14/22 Please note: this Letter Report does not represent authorization for the use of any Intertek certification marks. 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Solar Inverter for North America Rev 16.1 - 2/2022 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US MECHANICAL DESIGN Dimensions (W x H x D)16.7 x 23.2 x 5.9 in (425 x 590 x 150 mm) Display LED indicators Weight 3)41.9 lbs (19.0 kg) 41.9 lbs (19.0 kg) 44.3 lbs (20.1 kg) 45.2 lbs (20.5 kg) 47.6 lbs (21.6 kg) 47.6 lbs (21.6 kg) Cooling Natural convection Natural convection with internal fan DC connection Spring contact type AC connection Spring contact type Communication interface BLE, optional WiFi, Ethernet, 3G / 4G cellular communication Remote diagnose/monitoring Bi-direction via cloud Remote firmware update Via cloud (optional) Enclosure material Die-casting aluminum STANDARDS Enclosure protection rating Type 4 Safety UL 1741, CSA-C22.2 No. 107.1-16 Software approval UL 1998 Ground fault protection UL 1741 CRD Anti-islanding protection IEEE 1547-2018, IEEE 1547.1-2020 EMC FCC part 15 Class B AFCI UL 1699B (Type 1), NEC 2020 Article 690.11 Rapid shutdown protection NEC 2020 690.12 4) Rapid shutdown transmitter Optional pre-installed 5) Integrated meter ANSI C12.20, Class 0.5 Grid support regulation UL 1741 SB, California Rule 21 phase 1 & 2 & 3, HECO Compliant WARRANTY Standard warranty 10 years 1) Please refer to technical note for detailed string configuration 2) Without consumption of communication card 3) Without weight of revenue grade meter 4) Compliant with APS rapid shutdown system or Tigo rapid shutdown system. Compliant with Delta MCI or Delta Smart RSS as part of listed or field labeled PV Hazard Control System/PV Rapid Shutdown Array. 5) Optional pre-installed with APS rapid shutdown transmitter or Tigo rapid shutdown transmitter Delta Electronics (Americas), Ltd. 46101 Fremont Blvd, Fremont, CA 94538 Sales Email: Inverter.Sales@deltaww.com Support Email: Inverter.Support@deltaww.com Sales Hotline: +1-877-440-5851 or +1-626-369-8021 Support Hotline: +1-877-442-4832 Support (Intl.): +1-626-369-8019 Monday to Friday from 6am to 6pm PST (apart from Holidays) www.Delta-Americas.com Residential Energy Storage Solution for North America Rev 11 – 04/2022 © Copyright 2018 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Accessory: Rapid Shutdown System (RSS) Features: z With PLC, no additional wire needed for control z Comply with NEC 2020, Article 690.12* z String level rapid shutdown z Type 4 protection z Support rack mount or solar module mount z Support series connection up to 2 sub strings z With high voltage DC relay, high reliability RATINGS Model Name Smart RSS Delta part number GPI00010105 Maximum system voltage 600 Vdc Maximum current on controlled conductor 25 A dc @70ºC, 18.7 A dc @80ºC Rated input operating voltage 50 Vdc to 550 Vdc Rated input operating current 20 A @ 70 °C 15 A @ 80 °C Fuse Rating NA Self-power consumption <4 W GENERAL DATA Dimensions (W x H x D)6.0 x 7.9 x 2.1 in (152 x 201 x 53 mm) Weight 3.77 lbs (1.708 kg) Cooling Natural convection DC input/output connectors MC4 and H4 Enclosure material Die cast aluminum Operating temperature -40 °F to 176 °F (-40 °C to 80 °C) Humidity 0% to 95% Maximum operating altitude 9,843 ft (3,000 m) above sea level STANDARD COMPLIANCE Enclosure protection rating Type 4 Safety UL 1741, CSA C22.2 No. 330-17 Rapid shutdown NEC 2020 Article 690.12* EMC FCC Part 15 Class B *Installed with a listed or field labeled PV hazard control system 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Solar Inverter for North America Single Phase Solar Inverter for North America M4-TL-US | M5-TL-US | M6-TL-US | M8-TL-US | M10-TL-US | M10-4-TL-US Key Features: x Smart inverter with BLE, optional WiFi, Ethernet, 3G / 4G cellular communication x Optional revenue grade meter (compliant with ANSI C12.20, Class 0.5) x Support bi-directional cloud communication x Support remote diagnosis and OTA x Type 4 protection x Built-in AFCI & Rapid shutdown controller x CEC efficiency 97.5% x UL 1741 SB, HECO compliant x CA Rule 21 Phase 1 & 2 & 3 compliant Solar Inverter for North America Rev 16.1 - 2/2022 © Copyright 2020 Delta Electronics (Americas), Ltd. All rights reserved. Specifications subject to change without prior notice. Model M4-TL-US M5-TL-US M6-TL-US M8-TL-US M10-TL-US M10-4-TL-US INPUT (DC) Max. system voltage 600 V Nominal voltage 380 V Max. operating voltage 540 V Operating MPPT voltage range 50 V to 480 V Max. input current per MPPT 12 A 12 A 12 A 12 A 20 A 12 A Max. short circuit current per MPPT 15 A 15 A 15 A 15 A 30 A 15 A Max. DC/AC ratio 1)1.35 DC disconnect Integrated MPP tracker 2 2 3 3 2 4 Input strings available 2 - 2 2 - 2 2 - 2 - 2 2 - 2 - 2 2 - 2 2 - 2 - 2 - 2 OUTPUT (AC) Nominal output power @ 240Vac 3840 W 4800 W 5760 W 7680 W 9600 W 9600 W Max. output power @ 240Vac 4000 W 5000 W 6000 W 8000 W 10000 W 10000 W Nominal output power @ 208Vac 3328 W 4160 W 4992 W 6656 W 8320 W 8320 W Max. output power @ 208Vac 3648 W 4560 W 5472 W 7296 W 9120 W 9120 W AC operating voltage range 183 Vac to 228 Vac @ 208 Vac 211 Vac to 264 Vac @ 240 Vac Max. continuous current 16 A 20 A 24 A 32 A 40 A 40 A Nominal operating frequency 60 Hz Operating frequency range 59.3 Hz to 60.5 Hz Adjustable frequency range 50 Hz to 66 Hz Night consumption < 1.5 W 2) THD @ nominal power < 3 % Power factor @ nominal power > 0.99 Adjustable power factor range 0.85i to 0.85c GENERAL SPECIFICATION Max. efficiency 98% CEC efficiency 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.5 % @ 208 V 97.5 % @ 240 V 97.0 % @ 208 V 97.5 % @ 240 V Operating temperature range -22 °F to 149 °F (-30 °C to 65 °C) with derating above 113 °F (45 °C) Storage temperature range -40 °F to 185 °F (-40 °C to 85 °C) Humidity 0% to 95% Max. operating altitude 9,843 ft (3,000 m) Acoustic noise < 45 dB(A) @ 3 ft (1m) 2006 N Deodar St - 101118000 & 20181911 6/11/2024 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org           2006 Deodar St GAF Energy 1062345 Eric Crane 609-257-8353 eric.crane@gaf.energy 10/11/23 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Issue Date: 06-16-2022 Revised Date: 06-26-2023 Renewal Date: 06-30-2024 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report DIVISION: 07 – THERMAL AND MOISTURE PROTECTION Section: 07 31 00 - Roof Shingles and Shakes REPORT HOLDER: GAF Energy LLC 5981 Optical Court San Jose, California 95138 www.gaf.energy info@gaf.energy REPORT SUBJECT: Timberline Solar BIPV Roofing System Model TLS-1 1.0 SCOPE OF EVALUATION 1.1 This Research Report addresses compliance with the following Codes: • 2021, 2018 and 2015 International Building Code® (IBC) • 2021, 2018 and 2015 International Residential Code® (IRC) • 2023 and 2020 Florida Building Code (including High Velocity Hurricane Zones (HVHZ) (see Section 9) • 2020, 2017 and 2014 National Electrical Code (NEC), NFPA 70 NOTE: This report references the most recent Code editions cited. Section numbers in earlier editions may differ. 1.2 The Timberline Solar BIPV Roofing System has been evaluated for the following properties (see Table 1): • Material properties • Electrical Certification • Fire classification • Wind resistance • Impact resistance • Photovoltaic hazard control 1.3 The Timberline Solar BIPV Roofing System has been evaluated for the following uses (see Table 1): • Use as Building-integrated photovoltaic roof panels in accordance with IBC Section 1507.17 and IRC Section R905.17. The panels also satisfy requirements for photovoltaic shingles in accordance with IBC Section 1507.16 and IRC Section R905.16. • Use where a Class A, B or C Fire Classification in accordance with IBC Section 1505 and IRC Section R902.1 is required. • Use where a listed PV hazard control system or listed rapid shutdown PV array is required in accordance with NEC Article 690.12(B)(2)(1). 2.0 STATEMENT OF COMPLIANCE The GAF Energy LLC Timberline Solar BIPV Roofing System complies with the Codes listed in Section 1.1, for the properties stated in Section 1.2 and uses stated in Section 1.3, when installed as described in this report, including the Conditions of Use stated in Section 6. 3.0 DESCRIPTION 3.1 Timberline Solar BIPV modules: Timberline Solar BIPV modules are building-integrated photovoltaic coverings complying with IBC Sections 1505.16 and 1507.17 and IRC Sections R905.16 and R905.17. Panel dimensions are shown in Figure 1. 3.2 Asphalt shingles: The BIPV roofing system may be used in conjunction with asphalt shingles complying with the code. Installation requirements for the shingles are identified in Section 5.2. The BIPV roofing may be used in conjunction with GAF Timberline® Solar HD or Timberline® Solar HDZ asphalt shingles. The shingles are listed by UL for compliance with UL 790 (Class A fire classification), ICC-ES AC438, ASTM D3161 (Class F) and ASTM D7158 (Class H). See UL Listing TFWZ.R21. 3.3 Underlayment: Underlayment must comply with IBC Section 1507.1.1 or IRC Section R905.1.1. 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Page 2 of 9 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report 3.4 System components: Components for installation are provided by GAF Energy LLC and include the components shown in Figure 2. 4.0 PERFORMANCE CHARACTERISTICS 4.1 Material Standards: The Timberline Solar BIPV modules are listed by Intertek as complying with UL 7103, and both UL 61730-1 and 61730-2 in accordance with IBC Sections 1507.16.6 and 1507.17.5 and IRC Sections R905.16.4 and R905.17.5. 4.2 Wind Resistance: When installed in accordance with this report, the Timberline Solar BIPV Roofing System has demonstrated a Class F classification when tested in accordance with ASTM D3161 and complies with the requirements of TAS 107. 4.3 Wind-driven Rain: When installed in accordance with this report, the Timberline Solar BIPV Roofing System has demonstrated compliance with TAS 100. 4.4 Roof Classification: When installed in accordance with this report, the Timberline Solar BIPV Roofing System has demonstrated a Class A fire classification when tested in accordance with ASTM E108 (UL 790). 4.5 Impact Resistance: The BIPV modules have demonstrated a Class 1 rating when tested in accordance with UL 2218. Note, this is supplemental information; the building codes do not require impact resistance for roofing installed at slopes greater than 2:12. 4.6 Photovoltaic Hazard Control: The Timberline Solar BIPV Roofing System, in combination with the Delta Electronics components described below, are listed by Intertek for compliance with UL 3741, Photovoltaic Hazard Control, in accordance with NEC Article 690.12(B)(2)(1). The system is used where a rapid shutdown PV array is required. The system is used with the following components: • Delta Electronics Mid Circuit Interrupters • Delta Electronics Rapid Shutdown System • Delta Electronics M series inverters M4-TL-US, M5-TL-US, M6-TL-US, M8-TL-US, M10-4-TL-US. 5.0 INSTALLATION 5.1 General: The Timberline Solar BIPV Roofing System must be installed in accordance with the manufacturer’s published installation instructions, the applicable Code, and this Research Report. A copy of the manufacturer’s instructions must be available on the jobsite during installation. 5.2 Application: The Timberline Solar modules must be installed over an underlayment complying with IBC Section 1507.1.1 or IRC Section R905.1.1. on minimum 15/32-inch plywood or 7/16- inch OSB roof decks. Minimum slope is 2:12; maximum slope is not limited. Application of the underlayment must be in accordance with IBC Section 1507.17.4 and IRC Sections R905.1.1 and R905.1.2. Asphalt shingles used in conjunction with the BIPV roofing system must be shown to the satisfaction of the building official, to meet the applicable requirements of IBC Section 1504 and IRC Section R905.2. The shingles must additionally be classified as Class F in accordance with IBC Table 1504.2 and IRC Table R905.2.4.1 and must have Class A fire classification in accordance with IBC Section 1505 and IRC Section R902. The asphalt shingles must be installed with the same exposure as the BIPV modules, 7-9/16 inch. A minimum of one course of shingles must be installed at eaves and ridges. GAF Timberline® Solar HD or Timberline® Solar HDZ asphalt shingles must be installed with the manufacturer’s installation instructions. The shingles are sized to provide the same reveal as the Timberline Solar modules. The Timberline Solar modules must be nailed to the roof deck using six evenly spaced nails in the designated nailing zone. Nails must be 10-12 gauge, barbed, deformed, or smooth shank roofing nails with heads 3/8 in. to 7/16 in. diameter, and must comply with ASTM F1667. Fasteners must be long enough to penetrate at least 3/4 in. into wood decks or through plywood or OSB sheathing. The release liner on the module adhesive must be removed prior to 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Page 3 of 9 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report placement of the adjacent modules. When adjacent to asphalt shingles, the GAF Energy Step Flap must be installed 2 inches above the reveal line and must be nailed with two nails, one in each upper corner. Penetrations in the roof deck may occur only in the sections of the roof covering where the asphalt shingles are located. Penetrations must be flashed in accordance with applicable code requirements. 6.0 CONDITIONS OF USE 6.1 Installation must comply with this Research Report, the manufacturer’s published installation instructions, and the applicable Code. In the event of a conflict, this report governs. 6.2 The Timberline Solar BIPV Roofing System is manufactured under a quality control program with inspections by Intertek Testing Services NA, Inc. 7.0 SUPPORTING EVIDENCE 7.1 Reports of tests in accordance with UL 7103, UL 61730 (1 & 2), ASTM E108, UL 790, ASTM D3161, TAS 100, TAS 107, UL 2218, UL 3741 and UL 1703 Section 30. 7.2 Intertek Listing Report "GAF Energy LLC - Timberline Solar BIPV Roofing System", on the Intertek Directory of Building Products. 7.3 Intertek Listing Report “Photovoltaic Hazard Control” on the Intertek Directory of Listed Products. 7.4 Intertek Listing Report “Photovoltaic Module Safety Qualification Part 1 Requirements for Construction” on the Intertek Directory of Listed Products. 8.0 IDENTIFICATION The GAF Energy LLC Timberline Solar BIPV Roofing System is identified with the manufacturer’s name, the product name, a label indicating listing to UL 7103 and UL 61730 (1 & 2), the Intertek Mark as shown below, the Intertek Control Number and the Code Compliance Research Report number (CCRR- 0456). Packaging labels shall also include reference to TAS 107 and ASTM D3161, Class F. 9.0 OTHER CODES 9.1 Florida Building Code: The Timberline Solar BIPV Roofing System, described in Sections 2.0 through 7.0 of this Research Report, complies with the 2023 and 2020 Florida Building Code – Building and Florida Building Code – Residential, including High- velocity Hurricane Zones (HVHZ). Intertek is an approved evaluation entity and quality assurance entity pursuant to Florida Statute 553.842 – Product Evaluation and Approval. 9.2 National Electric Code: Timberline Solar, in combination with the Delta Electronics components and components that are listed under the user manual revision of Rev 2.1 has been evaluated as a system to the requirements in ANSI/CAN UL 3741 Photovoltaic Hazard Control. When installed in accordance with manufacturer’s installation instructions and this report, this its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Report. Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety, and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks. Any use of the Intertek name or one of its marks for the sale 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Page 4 of 9 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report system meets the requirements of Article 690.12 of the National Electrical Code for 2014, 2017 and 2020. The terms to describe this function vary slightly in each code cycle. 2014: “Rapid Shutdown” (RSD) Conductors leaving the array must drop to 30V or less within 10 seconds of rapid shutdown initiation. Equipment must be listed, but standards are not specified. 2014 NEC 690.12(2) and (5) 2017: “PV Rapid Shutdown Array” (PVRSA) A listed assembly or system designed to “reduce but not eliminate risk of electric shock hazard within a damaged PV array during fire- fighting procedures.” 2017 NEC 690.12(B)(2)(1) 2020 “PV Hazard Control System” (PVHCS) Equipment or multiple pieces of equipment listed to UL 3741 “to reduce the risk of electric shock hazard within a damaged PV array for fire fighters.” 2020 NEC 690.12(B)(2)(1) Refer to each code cycle of the NEC for more detail. See Table 2 for the approved list of PVHCS components (sub- assemblies not included). 10.0 CODE COMPLIANCE RESEARCH REPORT USE 10.1 Approval of building products and/or materials can only be granted by a building official having legal authority in the specific jurisdiction where approval is sought. 10.2 Code Compliance Research Reports shall not be used in any manner that implies an endorsement of the product by Intertek. 10.3 Reference to the https://bpdirectory.intertek.com is recommended to ascertain the current version and status of this report. 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Page 5 of 9 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report TABLE 1 - PROPERTIES EVALUATED PROPERTY 2021 IBC SECTION 2021 IRC SECTION 2023 FBC - Building 2023 FBC – Residential Material properties 1507.17.5 R905.17.5 1507.17.6 R905.17.5 Fire classification 1505.8 R902.3 R902 Wind resistance R905.16.7 Components 1506 R902 R902 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Page 6 of 9 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report TABLE 2 - PV Hazard Control System (PVHCS) Components (sub-assemblies not included) Component & Function Manufacturer Model No. Certification Standards Years of Compliance to 690.122 Rapid Shutdown System (Mid Circuit Interrupter (MCI)) Electronics GPI00010119 2020 System (Smart RSS) Electronics 2020 Electronics M5-TL-US M6-TL-US M8-TL-US 2020 (Solar Shingle) 2020 UL 61730 & UL 7103 1 within UL 3741 & 2020 Assembly 1 within UL 3741 & 2020 1 within UL 3741 & 2020 within UL 3741 & 2020 294000417 1 294000456 1 in end-product within 2020 1 Evaluated as part of the listed PV Hazard Control System. 2 See Section 9.2 for applicable code sections related to specific code years. 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Page 7 of 9 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report TABLE 2 (CONT.) INSTALLATION REQUIREMENTS Max System Voltage 600 VDC Max Array Internal Voltage After Actuation VDC OC MCI/RSS Voltage Output after Actuation ≤30 VDC Voltage Bleed-Down Interval ≤30 secs. Max Series-Connected Solar Shingles per (1) MCI or (1) RSS 48 OTHER INSTALLATION INSTRUCTIONS RECOMMENDED BY GAF Applicable for Integrated Rooftop Solar for Composition Shingle Steep Sloped Roofs, Installed Using 1. MCI or RSS shall be secured inside the Transition Box using provided fasteners. mounting plane subarray string. MCI and RSS may be installed on subarrays smaller than 48 series- connected solar shingles. For the most current specifications, instructions and limitations on the use of Delta Electronics components, please refer to their website at DC 22 VDC. The Solar Shingles have a VOC of 10.9 VDC. Minimum recommended number of Solar inspection by as-built string diagrams and/or voltage measurement logs. Voltage output per string not to exceed 600 VDC. 5. The RSS has a metal enclosure and shall be bonded to the EGC using the lay-in lug and M4 bolt provided, or by equivalent means approved in the NEC. sized, installed, and labeled in accordance with NEC requirements. The specific part shall be identified on the as-built system drawings. The inverters evaluated with this system are equipped 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Page 8 of 9 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report Figure 1 – Module Dimensions 2006 N Deodar St - 101118000 & 20181911 6/11/2024 Code Compliance Research Report CCRR-0456 Page 9 of 9 545 E. Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building PCA-101 Version: 28 December 2021 SFT-BC-CCRR-OP-19a Code Compliance Research Report Figure 2 – System Components 2006 N Deodar St - 101118000 & 20181911 6/11/2024 2006 N Deodar St - 101118000 & 20181911 6/11/2024 2006 N Deodar St - 101118000 & 20181911 6/11/2024