HomeMy WebLinkAbout1919 N Spurgeon St - PlanCity of Santa Ana, CA, Department of Building & Safety Subject: Review of PV Array installed on Existing Residence Project: Jimenez 1919 N Spurgeon St Santa Ana, CA V&A Project No. 22-3457 We have reviewed the existing home for the proposed PV array installation. Based upon our analysis, we have found that the existing home is sufficient to support the added load of the PV array. Analysis based upon: 2022 CBC Our professional services have been performed using the degree of care and skill ordinarily exercised under similar circumstances by reputable engineers practicing in this locality. No other warranty, expressed or implied, is made as to the professional options included in this report. We hope this provides you with the information you need at this time. Please call us if you have any questions regarding this report. Sincerely, VINCI & ASSOCIATES James R. Vinci, S.E. License No. S-4411 V I N C I & A S S O C I A T E S Structural Engineers 4/28/2023 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com 4/28/2023 1919 N Spurgeon St06/15/23 V I N C I & A S S O C I A T E S Structural Engineers STRUCTURAL CALCULATIONS FOR PHOTOVOLTAIC Santa Ana, CA CLIENT: Titan Solar Power 805.496.2100 • VinciSE.com 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ARRAY JOB NO: 22-3457 Jimenez 1919 N Spurgeon St 1919 N Spurgeon St06/15/23 DATE:V I N C I & A S S O C I A T E S SHEET:1 PROJECT:Jimenez Structural Engineers JOB NO.:22-3457 1919 N Spurgeon St 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power DESIGN DATA: ROOF DESIGN LOAD: ROOFING ( Concrete Tile )=12 psf SHEATHING =2 ROOF RAFTERS / TRUSS =2 MISCELLANEOUS =1 ROOF RAFTER/TRUSS DESIGN DEAD LOAD = 17.0 psf CEILING & INSULATION =3.25 MISCELLANEOUS =1.25 DESIGN DEAD LOAD =21.5 psf DESIGN LIVE LOAD =20 psf DESIGN SNOW LOAD =0 psf WIND DESIGN CRITERIA: BASIC WIND SPEED =100 mph WIND EXPOSURE =C NUMBER OF STORIES =2 ROOF SLOPE =30° SOLAR MODULE Solar Module Width:=43.23 in Solar Module Length:=67.8 in Solar Module Area =20.35 ft2 Solar Module Dead Load =2.68 psf Number of PV Modules =11 Number of Mounts to Roof =34 Maximum Spacing of Mounts =4 ft o.c. Tributary Area to Mounts 20.35 ft2 x ( 11 /34 ) = 6.59 ft2 (Average) ( 4 ft oc x 67.8 in / 12''/ft ) / 2 =11.30 ft2 (Worst Case) Solar Module Vertical Support Point Load 11.30 ft2 x 2.68 psf = 30.3 lbs TOTAL AREA OF ADDED SOLAR PANELS ( 3.60 ft x 5.65 ft ) x ( 11 Modules ) = 223.9 ft2 4/28/2023 -1919 N Spurgeon St06/15/23 DATE:V I N C I & A S S O C I A T E S SHEET:2 PROJECT:Jimenez Structural Engineers JOB NO.:22-3457 1919 N Spurgeon St 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power DESIGN CONNECTION TO ROOF TO RESIST WIND UPLIFT REFER TO NEXT SHEET FOR UPLIFT FORCE CALCULATIONS ZONE 1 UPLIFT = -.6(2.68psf) Design Force = ( Uplift x (0.6) ) -.6(2.68psf) Net Uplift = ADD 3.09 Connections per Module (MIN) CONNECTION 11 Modules, 34 Connections DETAIL Max Trib Area =ft2 HERE UPLIFT / CONN. = 11.3 ft2 x 23.0 psf = 260.2 lbs/conn PER 2018 NDS (TABLE 12.2A) PALLOW = 130 lbs/in x CD x Ct for (2) screws WITH 1.63'' PENETRATION INTO JOIST PALLOW = 1.63 '' x 208 lbs/in x 2 = 676 lbs > 260 lbs Therefore O.K. FACTOR OF SAFETY: F.O.S. = 2.60 > 1.5 Therefore O.K. ZONE 3 UPLIFT = - 0.6 (2.68 psf)ZONE 2 UPLIFT = -.6(2.68psf) Design Force = ( Uplift x (0.6) ) - 0.6 (2.68 psf)Design Force = ( Uplift x (0.6) ) -.6(2.68psf) Net Uplift = Net Uplift = 3.09 Connections per Module (MIN)3.09 Connections per Module (MIN) 11 Modules, 34 Connections 11 Modules, 34 Connections Max Trib Area = ft2 Max Trib Area = ft2 UPLIFT / CONN. = 7.537 ft2 x UPLIFT / CONN. = 11.3 ft2 x = 247.2 lbs/conn = 294 lbs/conn PER 2018 NDS (TABLE 12.2A)PER 2018 NDS (TABLE 12.2A) PALLOW = 130 lbs/in x CD x Ct PALLOW = 130 lbs/in x CD x Ct for (2) screws for (2) screws WITH 1.63'' PENETRATION INTO JOIST WITH 1.63'' PENETRATION INTO JOIST PALLOW = 1.63 '' x 208 lbs/in x 2 PALLOW = 1.63 '' x 208 lbs/in x 2 = 676 lbs > = 676 lbs > Therefore O.K.Therefore O.K. FACTOR OF SAFETY:FACTOR OF SAFETY: F.O.S. = 2.74 > 1.5 F.O.S. = 2.30 > 1.5 - 11.30 M5X60 M5X60 11.30 26.0 psf 4/28/2023 23.0 psf 41.1 psf 46.0 psf 57.3 psf 32.8 psf 294 lbs 26.0 psf M5X60 7.54 Therefore O.K. 32.8 psf 247 lbs Therefore O.K. 1919 N Spurgeon St06/15/23 DATE:V I N C I & A S S O C I A T E S SHEET:3 PROJECT:Jimenez Structural Engineers JOB NO.:22-3457 1919 N Spurgeon St 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com Company Titan Solar Power Wind Analysis Per ASCE 7-16 - Components and Cladding Exposure Category : C Importance Factor : 1 Basic Wind Speed : 100 Topographical factor : 1 Flat Bldg Ht to eave : 19 ft Bldg Ht to Ridge : 24 ft Bldg L : 42 ft Bldg W : 30 ft Effective area : 11.30 ft2 a = 3 (width of edge strips, ASCE 7, 28.3-1) Design pressures for Roof Top Solar Panels qh = 19.58 psf (q h = 0.00256K z K zt K d K e V 2 ) (ASCE 7, 26.10) Kz = 0.9 Kzt = 1 Kd = 0.85 Ke = 1 G Cp = External pressure coefficient ASCE 7, 30.3.2) G Cpi = 0.18 or -0.18 (ASCE 7, 26.13-1, Enclosed Building) Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r Zone 3 Zone 3e Zone 3r Zone 4 Zone 5 G Cp 0.88 -- 0.88 0.88 0.88 - 0.88 0.88 0.70 0.70 -G Cp -1.75 -- -1.75 -1.96 -1.75 - -2.44 -1.96 -0.80 0.00 (ASCE 7, 30.3-2A Roof Top Solar Panels (psf)Zone 1 Max Pressure = -41.05 psf GOVERNS ƳΕ = 1.5 (ASCE 7, 29.4-7)Zone 2 Max Pressure = -46.04 psf GOVERNS (USING WORST CASE EDGE FACTOR)Zone 3 Max Pressure = -57.33 psf GOVERNS p = qh (GCp ) (ƳΕ) (Ƴα) (ASCE 7, 29.4.4) Ƴα = 0.8 Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r Zone 3 Zone 3e Zone 3r Zone 4 Zone 5 Positive 20.65 20.65 20.65 20.65 20.65 20.65 16.45 16.45 Negative -41.05 -41.05 -46.04 -41.05 -57.33 -46.04 -18.80 0.00 Components and Cladding Pressure (psf) Zone 1 Max Pressure = -37.74 psf Zone 2 Max Pressure = -41.89 psf Zone 3 Max Pressure = -51.30 psf p = qh [(G Cp ) - (G Cpi)](pressure on component, ASCE 7, 30.3-1) p (min) = 16 psf (ASCE 7, 30.2.2) Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r Zone 3 Zone 3e Zone 3r Zone 4 Zone 5 Positive 20.73 20.73 20.73 20.73 20.73 20.73 19.69 19.69 Negative -37.74 -37.74 -41.89 -37.74 -51.30 -41.89 -21.93 -21.93 4/28/2023 - 1919 N Spurgeon St06/15/23 DATE:V I N C I & A S S O C I A T E S SHEET:4 PROJECT:Jimenez Structural Engineers JOB NO.:22-3457 1919 N Spurgeon St 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power LATERAL FORCES: (Base Shear Calculations - 2022 CBC / ASCE-16 ) SEISMIC: Site Class: D (Use D if unknown) S1= 0.468 (USGS Software)SS= 1.31 (USGS Software) Fv = 1.7 (Table 11.4-2)Fa = 1.2 (Table 11.4-1) I = 1.0 (Sec 1.5-2 ASCE 7-16) R = 6.5 (Table 12.2-1 ASCE 7-16) SMS = Fa * SS = 1.577 (Eq. 16-20)SDS = (Eq. 16-39) SM1= Fv * S1 = 0.796 (Eq. 16-21)SD1 = (Eq. 16-40) TL = 8 s (Fig 22-14, ASCE 7) Ts = SD1 / S DS = 0.505 s 80% x 0.505 = >0.182 s Ta = Ct * (hn)x = (Eq. 12.8-7)Ct = 0.02 (Table 12.8-2 ASCE 7-16) hn = 19.0 ft x = 0.75 (Table 12.8-2 ASCE 7-16) k = 1.0 * *GOVERNS * * VMIN = ( SDS) / ( R / I ) =0.16 W (Eq. 12.8-2 ASCE 7-16) NEED NOT EXCEED: IF T ≤ TL USE: V = ( SD1) / T *( R / I ) =W (Eq. 12.8-3 ASCE 7-16) IF T TL USE: V = ( SD1)*(TL) / T² *( R / I ) =W (Eq. 12.8-4 ASCE 7-16) SHALL NOT BE LESS THAN: V = W (Eq. 12.8-5 ASCE 7-16)0.01 19.71 0.45 4/28/2023 0.182 s 1.05 0.53 ²/3 * SMS = ²/3 * SM1 = 0.404 1919 N Spurgeon St06/15/23 4/28/23, 4:40 PM U.S. Seismic Design Maps https://www.seismicmaps.org 1/3 1919 N Spurgeon St, Santa Ana, CA 92706, USA Latitude, Longitude: 33.76238610000001, -117.8649262 Date 4/28/2023, 4:40:13 PM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.314 MCER ground motion. (for 0.2 second period) S1 0.468 MCER ground motion. (for 1.0s period) SMS 1.577 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.051 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.553 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.664 Site modified peak ground acceleration T L 8 Long-period transition period in seconds SsRT 1.314 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.413 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.517 Factored deterministic acceleration value. (0.2 second) S1RT 0.468 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.506 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.6 Factored deterministic acceleration value. (1.0 second) PGAd 0.629 Factored deterministic acceleration value. (Peak Ground Acceleration) PGAUH 0.553 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration 1919 N Spurgeon St06/15/23 DATE:V I N C I & A S S O C I A T E S SHEET:6 PROJECT:Jimenez Structural Engineers JOB NO.:22-3457 1919 N Spurgeon St 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power LATERAL FORCES:TWO STORY STRUCTURE 2022 CBC F1 hr = 5.0 ft SEISMIC BASE SHEAR: V = 0.162 W (SEE PREVIOUS) F2 h1-h2 = 9.0 ft h2 = 10.0 ft F1': ROOF = 22 PSF F2': FLOOR = 15 PSF WALLS = 7 TRIB 2ND FLR WALLS = 7 28.5 TRIB 1ST FLR WALLS = 7 x 0.162 29 4.61 PSF x 0.162 4.69 PSF F1 = F2 (F1' x h1)=6.06 psf (F1' x h1) + (F2' x h2) F2 = F1' + F2'= 9.30 psf WIND LOADS: ps = λ kzt Iw ps30 (Eq. 28.6-1) λ = 1.21 ps30A = psf psA psf Iw = 1.00 ps30B = psf psB psf kzt = 1.00 ps30C =psf psC psf ps30D =psf psD psf TOTAL F1ULT:= ( 5 ft + 9 ft /2 ) x (23.2704 psf +12.12 psf ) = 336.2088 plf >> 336 plf F1ASD:= plf x 0.6 = 201.7253 plf >> 202 plf F2ULT:= ( 9 ft /2 + 10 ft /2 ) x (23.2704 psf +12.12 psf ) = 336.2088 plf >> 672 plf F2ASD:= plf x 0.6 = 201.7253 plf >> 403 plf 4/28/2023 -12.12 15.39 -7.15 -10.00 - 12.70 -5.90 336.21 19.20 23.27 336.21 1919 N Spurgeon St06/15/23 DATE:V I N C I & A S S O C I A T E S SHEET:7 PROJECT:Jimenez Structural Engineers JOB NO.:22-3457 1919 N Spurgeon St 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power CHECK IMPACT OF NEW SOLAR PANELS ON SEISMIC LOAD ADD ROOF PLAN HERE TOTAL ROOF AREA: ( 42.0 ft x 30.0 ft ) + ( 0.0 ft x 0.0 ft ) + ( 0.0 ft x 0.0 ft ) + ( 0.0 ft x 0.0 ft ) = EXISTING ESTIMATED SEISMIC LOAD (BASE SHEAR) 1260 ft2 x 6.06 psf = 7630.39 lbs AREA OF ADDED SOLAR PANELS (PER PAGE 1)= ft2 WEIGHT OF PANELS: 2.68 psf ADDED SEISMIC LOAD: 2.68 psf x ft2 x 0.16 =97.0 lbs Therefore O.K. Per CEBC SECTION 503.4 223.9 223.9 =1.3% < 10%% INCREASE =97.0 7630.387485 4/28/2023 - 1260 ft2 1919 N Spurgeon St06/15/23 Check Top Chord of Existing Truss Apr. 28, 2023 16:41 Design Check Calculation Sheet WoodWorks Sizer 2023 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Roof-DL Dead Full Area No 10.00(24.0") psf Roof-LLR Roof constr. Full Area Yes 20.00(24.0") psf PV1 Dead Point No 2.25 30 lbs PV2 Dead Point No 6.25 30 lbs PV3 Dead Point No 6.75 30 lbs PV4 Dead Point No 10.75 30 lbs Self-weight Dead Full UDL No 1.2 plf Maximum Reactions (lbs) and Bearing Lengths (in) : 1.5' 8.5' 17.922' 15.5' Unfactored: Dead 148 279 74 Roof Live 193 332 129 Factored: Total 341 612 203 Bearing: Length 0.50* 0.52 0.50* Min req'd 0.50* 0.52** 0.50* *Minimum bearing length setting used: 1/2" for end supports and 1/2" for interior supports **Minimum bearing length governed by the required width of the supporting member. Lumber-soft, D.Fir-L, No.2, 2x4 (1-1/2"x3-1/2") Supports: All - Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 24.0" c/c; Total length: 18.06'; Clear span(horz): 1.5', 6.938', 6.938'; Volume = 0.7 cu.ft.; Slope: 30.0 deg Lateral support: top = continuous, bottom = at all supports; Repetitive factor: applied where permitted (refer to online help); This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 78 Fv' = 225 psi fv/Fv' = 0.35 Bending(+) fb = 1158 Fb' = 1941 psi fb/Fb' = 0.60 Bending(-) fb = 1762 Fb' = 1803 psi fb/Fb' = 0.98 Deflection: Interior Dead 0.11 = L/856 Live 0.24 = L/395 0.40 = L/240 in 0.61 Total 0.36 = L/270 0.54 = L/180 in 0.66 Cantil. Dead -0.08 = L/246 Live -0.17 = L/120 0.17 = L/120 in 1.00 Total -0.26 = L/80 0.23 = L/90 in 1.11 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 A0 PROJECT INFO VICINITY MAP PV NOTES VICINITY MAP AERIAL VIEW PROJECT SITE INFORMATION NAME: JESUS JIMENEZ ADDRESS:1919 N SPURGEON ST, SANTA ANA, CA 92706 PHONE: (714) 651-1532 EMAIL: Jrjimenez190466@gmail.com APN: 00315357 (ORANGE COUNTY) UTILITY: SCE AHJ: SANTA ANA CITY (CA) BUILDING INFO OCCUPANCY: R3-SFD CONSTRUCTION TYPE: VB # OF STORIES: 2 BLDG AREA (SQFT): 1138 SPRINKLERS: NONE ROOF AREA (SQFT): 1348 ENGINEERING CRITERIA FOR RACKING DESIGN WIND SPEED: 110 MPH WIND EXPOSURE CATEGORY: B GROUND SNOW LOAD: O PSF PROJECT SCOPE INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM PV EQUIPMENT QTY MODEL NO AND MANUFACTURER MODULES:11 MODEL#: HY-DH108P8-400 400W HYPERION MODULES OPTIMIZERS:11 S440 SOLAREDGE OPTIMIZERS AC COMBINER:1 SE3800H-US (240V) SOLAREDGE HD INVERTER SYSTEM SIZE:4.400 DC kW RATING 4.048 CEC AC RATING ARRAY AREA:20.35 SQFT x 11 = 223.90 SQFT MAIN SERVICE PANEL INFORMATION UTILITY: SCE EXISTING: YES UPGRADE: NO BUS RATING: (E)200A MAIN BREAKER: (E)200A PHASE: 1PH MB POSITION: END # OF WIRES: 3 DERATE?: NO VOLTAGE: 240V DERATE SIZE: N/A UTILITY FED: OH METER#: 222010-109642 SHEET INDEX A0 PROJECT INFO, VICINITY MAP, NOTES A1 SITE PLAN A2 MOUNTING ROOF PLAN E1 SINGLE LINE DIAGRAM E2 ELECTRICAL CALCULATIONS E3 - E3.1 REQUIRED SIGNAGE & DIRECTORY E4 - E4.1 MODULE DATA SHEET & CERTIFICATION E5 - E5.1 INVERTER DATA SHEET & CERTIFICATION E6 OPTIMIZER DATA SHEET S1 - S1.1 STANCHION DATA SHEET S2 RACKING DATA SHEET S3 - S3.3 RACKING ENGINEERING S4 RACKING GROUNDING S5 RACKING CERTIFICATION APPLICABLE CODES ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING 2022 APPLICABLE CODES 2022 CA BUILDING CODES (CBC) 2022 CA RESIDENTIAL CODES (CRC) 2022 CA MECHANICAL CODES (CMC) 2022 CA PLUMBING CODES (CPC) 2022 CA FIRE CODES (CFC) 2022 CA ELECTRICAL CODES (CEC) 2022 CA ENERGY CODES (CEnC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen) 4.400 DC kW SOLAR PV STRING INVERTER SYSTEM - ROOF MOUNT 1919 N SPURGEON ST, SANTA ANA, CA 92706 JIMENEZ RESIDENCE SOLAR PHOTOVOLTAIC SYSTEM NOTES 2022 CODE REFERENCE CEC 110.2 CEC 110.3 ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. CEC 110.26 WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT CEC ARTICLE 250 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT CEC 690.13 CEC 690.15 DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY ACCESSIBLE LOCATION NEAR THE EQUIPMENT CEC 690.12 RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12. CEC 705.40 THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED CEC 310.10(D) CEC 690.31(A) TO (F) ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR THE APPLICATION. CEC 690.31(C INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS CEC 110.14 FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC 690.31(B) ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION CEC 200.6, CEC 200.7 CEC 400.22 CEC 250.119 CEC 400.23 CEC 310.110(C) ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC 200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C). CEC 711.11(C)MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET CEC 705.12(B)CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES CFC 605.11.2 DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS CEC 250.97 METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED CEC 314.15 ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS CEC 690.31(C)(5) CEC 110.14. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IDENTIFIED AND LISTED FOR SUCH USE CEC 690.33 (D)(2) CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING” CEC 690.45 CEC 250.122 EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C). CEC 705.32 WHERE PROTECTION IS INSTALLED IN ACCORDANCE WITH 230.95, THE OUTPUT OF AN INTERACTIVE SYSTEM SHALL BE CONNECTED TO THE SUPPLY SIDE OF THE GROUND-FAULT PROTECTION. CEC 690.31(G)(4)THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10' O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS CEC 300.4 CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED CEC 310.15 WHERE RACEWAYS OR CABLES ARE EXPOSED TO DIRECT SUNLIGHT ON OR ABOVE ROOFTOPS, RACEWAYS OR CABLES SHALL BE INSTALLED A MINIMUM DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR CABLE OF 7∕8 IN. WHERE THE DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY IS LESS THAN 7∕8 IN., A TEMPERATURE ADDER OF 60°F SHALL BE ADDED TO THE OUTDOOR TEMPERATURE TO DETERMINE THE APPLICABLE AMBIENT TEMPERATURE FOR APPLICATION OF THE CORRECTION FACTORS IN TABLE 310.15(B)(2)(A) OR TABLE 310.15(B)(2)(B). CEC 690.56(C)IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). CEC 690.31(G)(4)LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN WHITE ON A RED BACKGROUND. CEC 690.31(G)(4) 690.56(C)IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT. CRC R324.7 CRC R302.1. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF 5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. CPC 906.1 EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE PROPOSED MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE MODULES CMC 802.6.1(1) CPC 509.6.1(1) EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1). CEC 250.52(A)(5) CEC 250.53(G) GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH SOIL CEC 250.104 FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDED PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY COMPANY. CRC R314.1 CRC R315.1 APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CRC R324.3 PHOTOVOLTAIC (PV) SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTIONS R324.3.1 THROUGH R324.7.1 AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE ELECTRICAL PORTION OF SOLAR PV SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. CRC R324.6 ROOF ACCESS, PATHWAYS AND SETBACK REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH R324.6.2.1. ACCESS AND MINIMUM SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESS FROM THE ROOF. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND EXTENDING 3' ABOVE THE ROOF. LADDERS SHALL BE OSHA APPROVED AND SECURED TO THE STRUCTURE FOR INSPECTION PURPOSES. CONTRACTORS ARE REQUIRED TO BE PRESENT FOR THE FIRST AND/OR FINAL INSPECTIONS. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. PROJECT SITE STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 4.28.2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101115455 Elec# 20179904 Issued 06/14/23 1919 N Spurgeon St 06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 SITE PLAN A1 LEGEND: (E) - EXISTING (N) - NEW (P) - PROPOSED SITE PLAN SCALE: 1/16"=1' (N) 11 -MODEL#: HY-DH108P8-400 400W HYPERION MODULES WITH S440 SOLAREDGE OPTIMIZERS (E)2 - STORY 1138 SQ FT (E) DRIVEWAY (E) 200A MAIN SERVICE PANEL SCE METER#: 222010-109642 N S P U R G E O N S T (N) SE3800H-US (240V) SETAPP SOLAREDGE HD INVERTER PROPERTY LINE 3 1 2 (N) 30A AC DISCONNECT PR O P E R T Y LINE PROPERTY LINE PR O P E R T Y L I N E 4 5 6 9 1 0 8 7 1 1 STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 4.28.2023 (E) TOOL SHED W/O ELECTRICAL REVISED: 6.13.2023 1919 N Spurgeon St06/15/23 D INVMSP JB 1 2 3'3' 18" MIN 18" MIN 3' 3' 2 X 4 RAFTER @ 24" OC 2 78" 1-5/ 8 " MIN PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R CA L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 MOUNTING PLAN SOLAR PANEL DEAD WEIGHT CALCULATION MODULE HYPERION WIDTH (IN)LENGTH (IN)AREA (SQFT) WEIGHT (LBS) QTY TOTAL MODULE AREA TOTAL MODULE WEIGHT 43.23 67.80 20.35 48.50 11 223.90 533.50 RACKING EVEREST RACKING WEIGHT LBS/LNFT MOUNTING SYSTEM WEIGHT TOTAL SYSTEM WEIGHT TOTAL ATTACHMENT POINTS POINT LOAD CALCS DISTRIBUTED LOAD CALCULATION .75 66.69 600.19 34 17.65 2.68 PSF NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 ROOF COVERAGE TOTAL MODULE AREA ROOF FACE AREA (SQFT) ROOF COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE 223.90 1348 16.61 % </= 33% 18" SET BACK AT RIDGE ROOF INFORMATION ROOF TYPE COMP SHINGLE ROOF - 2 LAYERS MAX RAFTERS TRUSS RAFTER SPACING (IN)ATTACHMENT SPACING 2 X 4 N/A 24" OC 48" OC A2 (N) 3/4" EMT CONDUIT RUN ABOVE ROOF OR UNDER EAVES WHERE POSSIBLE 7/8'' MINIMUM ABOVE THE ROOF CEC 310.15(B)(3)(C) (N) 34 TOTAL ATTACHMENTS @ 4FT ON CENTER (N) 11 - MODEL#: HY-DH108P8-400 400W HYPERION MODULES WITH S440 SOLAREDGE OPTIMIZERS STRING A - 11 MODULES FIRE ACCESS POINT#2 AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS. FIRE ACCESS POINT#1 AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS. LEGEND (E) EXISTING (N) NEW (P) PROPOSED CONDUIT RUN VIF VERIFY IN FIELD JUNCTION BOX MAIN SERVICE PANEL AC COMBINER INVERTER AC DISCONNECT SUBPANEL SOLAR METER FIRE ACCESS POINTS FIRE PATHWAY/SETBACKS JB MSP D SP INV AC M x MOUNTING PLAN SCALE: 3/32"=1' NOTE: ALL DIMENSIONS SHOWN RELATING TO EXISTING CONSTRUCTION ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY ALL ACTUAL DIMENSIONS. DIMENSIONS, UNLESS NOTED +/- IR VIF (VERIFY IN FIELD), EXACT LOCATIONS, DISTANCES, ELEVATIONS AND SIMILAR DATA SHALL BE GOVERNED BY ACTUAL FIELD CONDITIONS. A (E) 200A MAIN SERVICE PANEL SCE METER#: 222010-109642 (N) SE3800H-US (240V) SETAPP SOLAREDGE HD INVERTER (N) 30A AC DISCONNECT A A A A A A A A A A 3FT FIRE PATHWAY 3FT FIRE PATHWAY 271° AZIMUTH 20.0° SLOPE 270° AZIMUTH 30.0° SLOPE 90° AZIMUTH 30.0° SLOPE MODULE EVEREST CROSSRAIL 44-X EVEREST SPLICE FOOT X END CLAMP ASSEMBLY EVEREST K2 SOLAR SEAL BUTYL PAD 2 - MSX60 SELF-DRILLING WOOD SCREWS THROUGH 7/16" OSB DIRECTL INTO THE RAFTER FULLY THREADED, 1-5/8" OF EMBEDMENT INTO RAFTER ROOF ATTACHMENT DETAIL COMP SHINGLE ROOF SCALE: 2" = 1'-0" SIDE VIEW NOTE: MODULES WILL BE INSTALLED FLUSHED TO EXISTING ROOF SLOPE STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 4.28.2023 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY:RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 AS BUILT REVISION LAYOUT CHANGE16-30-23 A0 PROJECT INFO VICINITY MAP PV NOTES VICINITY MAP AERIAL VIEW PROJECT SITE INFORMATION NAME: JESUS JIMENEZ ADDRESS:1919 N SPURGEON ST, SANTA ANA, CA 92706 PHONE: (714) 651-1532 EMAIL: Jrjimenez190466@gmail.com APN: 00315357 (ORANGE COUNTY) UTILITY: SCE AHJ: SANTA ANA CITY (CA) BUILDING INFO OCCUPANCY: R3-SFD CONSTRUCTION TYPE: VB # OF STORIES: 2 BLDG AREA (SQFT): 1138 SPRINKLERS: NONE ROOF AREA (SQFT): 1348 ENGINEERING CRITERIA FOR RACKING DESIGN WIND SPEED: 110 MPH WIND EXPOSURE CATEGORY: B GROUND SNOW LOAD: O PSF PROJECT SCOPE INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM PV EQUIPMENT QTY MODEL NO AND MANUFACTURER MODULES:11 MODEL#: HY-DH108P8-400 400W HYPERION MODULES OPTIMIZERS:11 S440 SOLAREDGE OPTIMIZERS AC COMBINER:1 SE3800H-US (240V) SOLAREDGE HD INVERTER SYSTEM SIZE:4.400 DC kW RATING 4.048 CEC AC RATING ARRAY AREA:20.35 SQFT x 11 = 223.90 SQFT MAIN SERVICE PANEL INFORMATION UTILITY: SCE EXISTING: YES UPGRADE: NO BUS RATING: (E)200A MAIN BREAKER: (E)200A PHASE: 1PH MB POSITION: END # OF WIRES: 3 DERATE?: NO VOLTAGE: 240V DERATE SIZE: N/A UTILITY FED: OH METER#: 222010-109642 SHEET INDEX A0 PROJECT INFO, VICINITY MAP, NOTES A1 SITE PLAN A2 MOUNTING ROOF PLAN E1 SINGLE LINE DIAGRAM E2 ELECTRICAL CALCULATIONS E3 - E3.1 REQUIRED SIGNAGE & DIRECTORY E4 - E4.1 MODULE DATA SHEET & CERTIFICATION E5 - E5.1 INVERTER DATA SHEET & CERTIFICATION E6 OPTIMIZER DATA SHEET S1 - S1.1 STANCHION DATA SHEET S2 RACKING DATA SHEET S3 - S3.3 RACKING ENGINEERING S4 RACKING GROUNDING S5 RACKING CERTIFICATION APPLICABLE CODES ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING 2022 APPLICABLE CODES 2022 CA BUILDING CODES (CBC) 2022 CA RESIDENTIAL CODES (CRC) 2022 CA MECHANICAL CODES (CMC) 2022 CA PLUMBING CODES (CPC) 2022 CA FIRE CODES (CFC) 2022 CA ELECTRICAL CODES (CEC) 2022 CA ENERGY CODES (CEnC) 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen) 4.400 DC kW SOLAR PV STRING INVERTER SYSTEM - ROOF MOUNT 1919 N SPURGEON ST, SANTA ANA, CA 92706 JIMENEZ RESIDENCE SOLAR PHOTOVOLTAIC SYSTEM NOTES 2022 CODE REFERENCE CEC 110.2 CEC 110.3 ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. CEC 110.26 WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT CEC ARTICLE 250 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT CEC 690.13 CEC 690.15 DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY ACCESSIBLE LOCATION NEAR THE EQUIPMENT CEC 690.12 RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12. CEC 705.40 THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED CEC 310.10(D) CEC 690.31(A) TO (F) ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR THE APPLICATION. CEC 690.31(C INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS CEC 110.14 FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC 690.31(B) ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION CEC 200.6, CEC 200.7 CEC 400.22 CEC 250.119 CEC 400.23 CEC 310.110(C) ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC 200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C). CEC 711.11(C)MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET CEC 705.12(B)CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES CFC 605.11.2 DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS CEC 250.97 METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED CEC 314.15 ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS CEC 690.31(C)(5) CEC 110.14. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IDENTIFIED AND LISTED FOR SUCH USE CEC 690.33 (D)(2) CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING” CEC 690.45 CEC 250.122 EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C). CEC 705.32 WHERE PROTECTION IS INSTALLED IN ACCORDANCE WITH 230.95, THE OUTPUT OF AN INTERACTIVE SYSTEM SHALL BE CONNECTED TO THE SUPPLY SIDE OF THE GROUND-FAULT PROTECTION. CEC 690.31(G)(4)THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10' O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS CEC 300.4 CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED CEC 310.15 WHERE RACEWAYS OR CABLES ARE EXPOSED TO DIRECT SUNLIGHT ON OR ABOVE ROOFTOPS, RACEWAYS OR CABLES SHALL BE INSTALLED A MINIMUM DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR CABLE OF 7∕8 IN. WHERE THE DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY IS LESS THAN 7∕8 IN., A TEMPERATURE ADDER OF 60°F SHALL BE ADDED TO THE OUTDOOR TEMPERATURE TO DETERMINE THE APPLICABLE AMBIENT TEMPERATURE FOR APPLICATION OF THE CORRECTION FACTORS IN TABLE 310.15(B)(2)(A) OR TABLE 310.15(B)(2)(B). CEC 690.56(C)IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). CEC 690.31(G)(4)LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN WHITE ON A RED BACKGROUND. CEC 690.31(G)(4) 690.56(C)IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT. CRC R324.7 CRC R302.1. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF 5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. CPC 906.1 EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE PROPOSED MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE MODULES CMC 802.6.1(1) CPC 509.6.1(1) EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1). CEC 250.52(A)(5) CEC 250.53(G) GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH SOIL CEC 250.104 FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDED PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY COMPANY. CRC R314.1 CRC R315.1 APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CRC R324.3 PHOTOVOLTAIC (PV) SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH SECTIONS R324.3.1 THROUGH R324.7.1 AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. THE ELECTRICAL PORTION OF SOLAR PV SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE. CRC R324.6 ROOF ACCESS, PATHWAYS AND SETBACK REQUIREMENTS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R324.6.1 THROUGH R324.6.2.1. ACCESS AND MINIMUM SPACING SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, TO PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESS FROM THE ROOF. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND EXTENDING 3' ABOVE THE ROOF. LADDERS SHALL BE OSHA APPROVED AND SECURED TO THE STRUCTURE FOR INSPECTION PURPOSES. CONTRACTORS ARE REQUIRED TO BE PRESENT FOR THE FIRST AND/OR FINAL INSPECTIONS. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. PROJECT SITE STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 06.30.2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. REVISION TO 101115455 Issued 06/14/23 101115782 Issued 07/17/23 Change to layout 1919 N Spurgeon St 07/17/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 AS BUILT REVISION LAYOUT CHANGE16-30-23 SITE PLAN A1 LEGEND: (E) - EXISTING (N) - NEW (P) - PROPOSED SITE PLAN SCALE: 1/16"=1' (N) 11 -MODEL#: HY-DH108P8-400 400W HYPERION MODULES WITH S440 SOLAREDGE OPTIMIZERS (E)2 - STORY 1138 SQ FT (E) DRIVEWAY (E) 200A MAIN SERVICE PANEL SCE METER#: 222010-109642 N S P U R G E O N S T (N) SE3800H-US (240V) SETAPP SOLAREDGE HD INVERTER PROPERTY LINE 1 2 (N) 30A AC DISCONNECT PRO P E R T Y LINE PROPERTY LINE PR O P E R T Y L I N E 5 6 7 4 1 0 1 1 9 8 3 (E) TOOL SHED W/O ELECTRICAL 1 STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 06.30.2023 1919 N Spurgeon St07/17/23 D INVMSP JB 1 2 3'3' 18" MIN 18" MIN 3' 3' 2 X 4 RAFTER @ 24" OC 2 78" 1-5/ 8 " MIN PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R CA L I I N C. SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 AS BUILT REVISION LAYOUT CHANGE16-30-23 MOUNTING PLAN SOLAR PANEL DEAD WEIGHT CALCULATION MODULE HYPERION WIDTH (IN)LENGTH (IN)AREA (SQFT) WEIGHT (LBS) QTY TOTAL MODULE AREA TOTAL MODULE WEIGHT 43.23 67.80 20.35 48.50 11 223.90 533.50 RACKING EVEREST RACKING WEIGHT LBS/LNFT MOUNTING SYSTEM WEIGHT TOTAL SYSTEM WEIGHT TOTAL ATTACHMENT POINTS POINT LOAD CALCS DISTRIBUTED LOAD CALCULATION .75 66.69 600.19 32 18.76 2.68 PSF NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 ROOF COVERAGE TOTAL MODULE AREA ROOF FACE AREA (SQFT) ROOF COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE 223.90 1348 16.61 % </= 33% 18" SET BACK AT RIDGE ROOF INFORMATION ROOF TYPE COMP SHINGLE ROOF - 2 LAYERS MAX RAFTERS TRUSS RAFTER SPACING (IN)ATTACHMENT SPACING 2 X 4 N/A 24" OC 48" OC A2 (N) 3/4" EMT CONDUIT RUN ABOVE ROOF OR UNDER EAVES WHERE POSSIBLE 7/8'' MINIMUM ABOVE THE ROOF CEC 310.15(B)(3)(C) (N) 32 TOTAL ATTACHMENTS @ 4FT ON CENTER (N) 11 - MODEL#: HY-DH108P8-400 400W HYPERION MODULES WITH S440 SOLAREDGE OPTIMIZERS STRING A - 11 MODULES FIRE ACCESS POINT#2 AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS. FIRE ACCESS POINT#1 AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS. LEGEND (E) EXISTING (N) NEW (P) PROPOSED CONDUIT RUN VIF VERIFY IN FIELD JUNCTION BOX MAIN SERVICE PANEL AC COMBINER INVERTER AC DISCONNECT SUBPANEL SOLAR METER FIRE ACCESS POINTS FIRE PATHWAY/SETBACKS JB MSP D SP INV AC M x MOUNTING PLAN SCALE: 3/32"=1' NOTE: ALL DIMENSIONS SHOWN RELATING TO EXISTING CONSTRUCTION ARE APPROXIMATE. THE CONTRACTOR SHALL FIELD VERIFY ALL ACTUAL DIMENSIONS. DIMENSIONS, UNLESS NOTED +/- IR VIF (VERIFY IN FIELD), EXACT LOCATIONS, DISTANCES, ELEVATIONS AND SIMILAR DATA SHALL BE GOVERNED BY ACTUAL FIELD CONDITIONS. A (E) 200A MAIN SERVICE PANEL SCE METER#: 222010-109642 (N) SE3800H-US (240V) SETAPP SOLAREDGE HD INVERTER (N) 30A AC DISCONNECT A A A A A 3FT FIRE PATHWAY 3FT FIRE PATHWAY 271° AZIMUTH 20.0° SLOPE 270° AZIMUTH 30.0° SLOPE 90° AZIMUTH 30.0° SLOPE MODULE EVEREST CROSSRAIL 44-X EVEREST SPLICE FOOT X END CLAMP ASSEMBLY EVEREST K2 SOLAR SEAL BUTYL PAD 2 - MSX60 SELF-DRILLING WOOD SCREWS THROUGH 7/16" OSB DIRECTL INTO THE RAFTER FULLY THREADED, 1-5/8" OF EMBEDMENT INTO RAFTER ROOF ATTACHMENT DETAIL COMP SHINGLE ROOF SCALE: 2" = 1'-0" SIDE VIEW NOTE: MODULES WILL BE INSTALLED FLUSHED TO EXISTING ROOF SLOPE A A A A A 1 STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 06.30.2023 1919 N Spurgeon St07/17/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 AS BUILT REVISION LAYOUT CHANGE1 6-30-23 REQUIRED SIGNAGE E3.1 MAIN SERVICE PANEL SOLAR ARRAYS INVERTER DIRECTORY PLACARD 6" 6" CAUTION DR I V E W A Y ADDRESS: 1919 N SPURGEON ST N S P U R G E O N S T 2 LABELING REQUIREMENTS 2022 CODE REFERENCE CEC 690.13(B) EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED "PV SYSTEM DISCONNECT" OR EQUIVALENT. ADDITIONAL MARKINGS SHALL BE PERMITTED BASED UPON THE SPECIFIC SYSTEM CONFIGURATION. FOR PV SYSTEM DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION.THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 110.21(B). CEC 690.56(C) BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. CEC 690.31(B)(1) PV SYSTEM DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED AT ALL TERMINATION, CONNECTION, AND SPLICE POINTS BY COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. CONDUCTORS RELYING ON OTHER THAN COLOR CODING FOR POLARITY IDENTIFICATION SHALL BE IDENTIFIED BY AN APPROVED PERMANENT MARKING MEANS SUCH AS LABELING, SLEEVING, OR SHRINK-TUBING THAT IS SUITABLE FOR THE CONDUCTOR SIZE. CEC 690.31(D)(2) UNLESS LOCATED AND ARRANGED SO THE PURPOSE IS EVIDENT, THE FOLLOWING WIRING METHODS AND ENCLOSURES THAT CONTAIN PV SYSTEM DC CIRCUIT CONDUCTORS SHALL BE MARKED WITH THE WORDING PHOTOVOLTAIC POWER SOURCE OR SOLAR PV DC CIRCUIT BY MEANS OF PERMANENTLY AFFIXED LABELS OR OTHER APPROVED PERMANENT MARKING: (1) EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS (2) COVERS OR ENCLOSURES OF PULL BOXES AND JUNCTION BOXES (3) CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. THE LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION. ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 9.5 MM (3∕8 IN.) IN WHITE ON A RED BACKGROUND. LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. SPACING BETWEEN LABELS OR MARKINGS, OR BETWEEN A LABEL AND A MARKING, SHALL NOT BE MORE THAN 3 M (10 FT). LABELS REQUIRED BY THIS SECTION SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. CEC 690.31(E) SOLIDLY GROUNDED BIPOLAR PV SYSTEMS SHALL BE CLEARLY MARKED WITH A PERMANENT, LEGIBLE WARNING NOTICE INDICATING THAT THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT. CEC 690.33(D)(2)INTERRUPTION OF CIRCUIT. CONNECTORS SHALL BE A TYPE THAT REQUIRES THE USE OF A TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING.” CEC 690.52 ALTERNATING-CURRENT MODULES SHALL BE MARKED WITH IDENTIFICATION OF TERMINALS OR LEADS AND WITH IDENTIFICATION OF THE FOLLOWING RATINGS. CEC 690.53 A PERMANENT READILY VISIBLE LABEL INDICATING THE HIGHEST MAXIMUM DC VOLTAGE IN A PV SYSTEM, CALCULATED IN ACCORDANCE WITH 690.7, SHALL BE PROVIDED BY THE INSTALLER AT ONE OF THE FOLLOWING LOCATIONS: (1) DC PV SYSTEM DISCONNECTING MEANS (2) PV SYSTEM ELECTRONIC POWER CONVERSION EQUIPMENT (3) DISTRIBUTION EQUIPMENT ASSOCIATED WITH THE PV SYSTEM. CEC 690.54 ALL INTERACTIVE SYSTEM(S) POINTS OF INTERCONNECTION WITH OTHER SOURCES SHALL BE MARKED AS AN ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. CEC 690.55 THE PV SYSTEM OUTPUT CIRCUIT CONDUCTORS SHALL BE MARKED TO INDICATE POLARITY WHERE CONNECTED TO ENERGY STORAGE SYSTEMS. CEC 690.56(B) PLAQUES OR DIRECTORIES SHALL BE INSTALLED IN ACCORDANCE WITH 705.10 AND 712.10. CEC 690.56(C) THE TYPE OF PV SYSTEM IS SHOWN IN FIGURE 690.56 (C). CEC 690.56(C)(2) A RAPID SHUTDOWN INITIATION DEVICE SHALL HAVE A LABEL LOCATED ON OR NO MORE THAN 1 M (3 FT) FROM THE INITIATION DEVICE THAT INCLUDES THE FOLLOWING WORDING: RAPID SHUTDOWN FOR SOLAR PV SYSTEM THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 9.5 MM (3∕8 IN.), IN WHITE ON RED BACKGROUND. CEC 690.59 PV SYSTEMS CONNECTED TO OTHER SOURCES SHALL BE INSTALLED IN ACCORDANCE WITH PARTS I AND II OF ARTICLE 705. CEC 705.12(B)(3)(3) THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT DEVICES ON PANELBOARDS, BOTH LOAD AND SUPPLY DEVICES, EXCLUDING THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR, SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. THE RATING OF THE OVERCURRENT DEVICEPROTECTING THE BUSBAR SHALL NOT EXCEED THE RATING OF THE BUSBAR. PERMANENT WARNING LABELSSHALL BE APPLIED TO DISTRIBUTION EQUIPMENT DISPLAYING THE FOLLOWING OR EQUIVALENT WORDING: WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICESHALL NOT EXCEED AMPACITY OF BUSBAR. CEC 705.12(D)SUITABLE FOR BACKFEED. FUSED DISCONNECTS, UNLESS OTHERWISE MARKED, SHALL BE CONSIDERED SUITABLE FOR BACKFEED. CEC 706.15(C) EACH ESS DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IT IS IN THE OPEN (ON) OR CLOSED (OFF) POSITION AND BE PERMANENTLY MARKED “ENERGY STORAGE SYSTEM DISCONNECT" THE DISCONNECTING MEANS SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE THE FOLLOWING: NOMINAL ESS AC VOLTAGE AND MAXIMUM ESS DC VOLTAGE AVAILABLE FAULT CURRENT DERIVED FROM THE ESS AN ARC-FLASH LABEL APPLIED IN ACCORDANCE WITH ACCEPTABLE INDUSTRY PRACTICE DATA CALCULATION WAS PERFORMED. CEC 110.27(C) ENTRANCES TO ROOMS OR OTHER GUARDED LOCATIONS THAT CONTAIN EXPOSED LIVE PARTS SHALL BE MARKED WITH CONSPICUOUS WARNING SIGNS FORBIDDING UNQUALIFIED PERSONS TO ENTER. CEC 705.10 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED AT A BUILDING SUPPLIED BY A STAND-ALONE SYSTEM AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN APPROVED READILY VISIBLE LOCATION. THE PLAQUE OR DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS FOR THE PREMISES OR BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. THE MARKING SHALL COMPLY WITH 110.21(B). CEC 705.12(C) EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. CEC 705.12(B)(3)(3) PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT DISPLAYING THE FOLLOWING OR EQUIVALENT WORDING: THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR. CEC 705.12(B)(3)(2) A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER POWER SOURCE THAT DISPLAYS THE FOLLOWING OR EQUIVALENT WORDING: “WARNING: POWER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DRIVE.” CEC 705.10 & 690.56(A)(B) 705.10 IDENTIFICATION OF POWER SOURCES A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN APPROVED READILY VISIBLE LOCATION. THE PLAQUE OR DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS FOR THE BUILDING OR STRUCTURE AND BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. THE PLAQUE OR DIRECTORY SHALL BE MARKED WITH THE WORDING "CAUTION: MULTIPLE SOURCES OF POWER." ANY POSTED DIAGRAMS SHALL BE CORRECTLY ORIENTED WITH RESPECT TO THE DIAGRAM'S LOCATION. THE MARKING SHALL COMPLY WITH 110.21(B). EXCEPTION: INSTALLATIONS WITH MULTIPLE CO-LOCATED POWER PRODUCTION SOURCES SHALL BE PERMITTED TO BE IDENTIFIED AS A GROUP(S). THE PLAQUE OR DIRECTORY SHALL NOT BE REQUIRED TO IDENTIFY EACH POWER SOURCE INDIVIDUALLY. MULTIPLE SOURCES OF POWER AC DISCO 1 1919 N Spurgeon St07/17/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 ELECTRICAL LINE DIAGRAM (N) SE3800H-US (240V) SOLAREDGE HD INVERTER(N) 11 - MODEL#: HY-DH108P8-400 400W HYPERION MODULES WITH S440 SOLAREDGE OPTIMIZERS (N)JBOX NEMA 3R ... DC1 WITH INTEGRATED DC DISCONNECT AND AUTOMATIC RAPID SHUTDOWN UPON AC GRID DISCONNECT DC AC N G OPTIMIZER ISC CALCULATION MAX# OF MODULES X MODULE WATTAGE 4400 = 11.00 AMPSNOMIMAL DC INPUT VOLTAGE OF INVERTER 400 (OPTIMIZER MAX OUTPUT CURRENT) [CEC 690.8]15 > 11.00 = OK AMPS AMPS 13.79A (MODULE ISC) </= 14.50A (OPTIMIZER ISC) = OK OPTIMIZER VOC CALCULATION LARGEST MODULE VOC FOR SINGLE-MODULE DC/DC CONVERTER CONFIGURATIONS (WITH 80V AFCI CAP) (CEC 690.7 and 690.11) MODULE VOC ____ X # OF MODULES PER CONVERTER ___X CF = V MODULE VOC 37.07 TL IS GREATER THAN OR EQUAL TO -5°C, CF 1.12 MODULES PER OPTIMIZER 1.00 VOLTS 41.52 THE VALUE CALCULATED MUST BE LESS THAN OPTIMIZERS MAX DC INPUT VOLTAGE 60V > 41.52 OK OPTIMIZER SPECIFICATION MAKE SOLAREDGE S440 MAXIMUM INPUT DC POWER 440 MAX INPUT VOLTAGE (VOC)60 V SHORT CIRCUIT CURRENT (ISC)14.50 A MAX OUTPUT CURRENT 15 A MAX OUTPUT VOLTAGE 60 V MODULE SPECIFICATION MANUFACTURER HYPERION MODEL NO.HY-DH108P8-400 PEAK POWER 400 W RATED VOLTAGE (Vmp)31.01 V RATED CURRENT (Imp)12.90 A OPEN CIRCUIT VOLTAGE (Voc)37.07 V SHORT CIRCUIT CURRENT (Isc)13.79 A INVERTER SPECIFICATION INVERTER MAKE SOLAREDGE INVERTER MODEL NO.SE3800H-US (240V) MAX INPUT VOLTAGE 480 V MAX INPUT CURRENT 10.5 A NOMIMAL AC VOLTAGE 240 V MAX AC CURRENT 16 A THIS DISCONNECT WILL BE THE RAPID SHUTDOWN INITIATION DEVICE TO COMPLY WITH CEC 690.12 (C) STRING A - 11 G E1 DC2 AC1 AC2 EATON DG221URB 30A, 2P, 240V, TYPE DG, NON-FUSIBLE, NEMA 3R (N) 30A AC DISCONNECT WIRE/CONDUIT SCHEDULE NOTE: TERMINATE LUGS AT 75°. WIRING/CONDUIT RACEWAY WILL BE MIN 7/8'' ABOVE THE ROOF TAG DESCRIPTION &21'8&725 7<3(6,=(48$17,7<CONDUIT SIZE/TYPE DC1 ARRAY TO JBOX 2 #10 AWG 1+ & 1- PV WIRE FREE AIR 1 #6 AWG GND- BARE COPPER DC2 JBOX TO INVERTER 2 #10 AWG 1+ & 1- THWN-2 3/4" EMT 1 #8 AWG GND THWN-2 AC1 INVERTER TO AC DISCONNECT 3 #10 AWG L1, L2 & N THWN-2 3/4" EMT 1 #8 AWG GND THWN-2 AC2 AC DISCONNECT TO MAIN SERVICE PANEL 3 #10 AWG L1, L2 & N THWN-2 3/4" EMT 1 #8 AWG GND THWN-2 INTERCONNECTION COMPLIANCE PER 705 CODE MAX AC OUTPUT OF INVERTER WITH 125% MAX AC OUTPUT (AMPS) TOTAL # INVERTER TOTAL MAX AC OUTPUT 125% RESULT (AMPS)OCPD SIZE 16.00 1 16.00 1.25 20.00 20A SERVICE PANEL CALCULATIONS WITH 120% BUS RATING SIZE MUTIPLIER (120%)RESULT MAIN BREAKER INVERTER AC OUTPUT+125%RESULT 200 1.20 240 200 20.00 220.00 240.00 >/=220.00 = OK INTERCONNECTION COMPLIANCE CODE REFERENCE: 705.12(B)(3)BUSBARS (2) Where two sources, one a primary power source and the other another power source, are located at opposite ends of a busbar that contains loads, the sum of 125 percent of the power-source(s) output circuit current and the rating of the overcurrent device protecting the busbar shall not exceed 120 percent of the ampacity of the busbar. The busbar shall be sized for the loads connected in accordance with Article 220. A permanent warning label shall be applied to the distribution equipment adjacent to the back-fed breaker from the power source that displays the following or equivalent wording: WARNING: POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE. The warning sign(s) or label(s) shall comply with 110.21(B). NOTE: 1) PV BREAKER MUST BE INSTALLED AT THE FARTHEST, OPPOSITE END OF MAIN BREAKER 2) SOLAR GROUND TYING INTO THE UFER GROUND POINT M G N (E)200A (N)20A MCB PV OCPD SCE METER# 222010- 109642 EARTH GROUND EXISTING 200A MAIN SERVICE PANEL 240V, 1-PHASE, 3W END FED 1919 N Spurgeon St06/15/23 ELECTRICAL CALCULATIONS PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 E2 MODULE SPECIFICATION INVERTER SPECIFICATION LOCATION INFORMATION MANUFACTURER HYPERION INVERTER MAKE SOLAREDGE NEC TABLE 310.15 (B)(2)(a)-TEMP CORRECTION FACTORS MODEL NO.HY-DH108P8-400 INVERTER MODEL NO.SE3800H-US (240V)HIGH TEMP 39 PEAK POWER 400 WATTS MAX INPUT VOLTAGE 480 VOLTS LOW TEMP -7 MPP VOLTAGE (VMPP)31.01 VOLTS MAX INPUT CURRENT 10.5 AMPS VOLTAGE CORRECTION FACTOR 1.12 MPP CURRENT (IMPP)12.90 AMPS NOMIMAL AC VOLTAGE 240 VOLTS ROOF TEMP + 33°-IF RACEWAY CONDUIT IS LESS THAN 7/8" ABOVE ROOF 72 OPEN CIRCUIT VOLTAGE (VOC)37.07 VOLTS MAX AC CURRENT 16 AMPS TEMP CORRECTION FACTOR (EXPOSED)0.50 SHORT CIRCUIT CURRENT (ISC)13.79 AMPS TEMP CORRECTION FACTOR (INSIDE CONDUIT)0.91 OPTIMIZER SPECIFICATION MAKE SOLAREDGE MODEL NUMBER S440 MAXIMUM INPUT DC POWER 440 WATTS ABSOLUTE MAX INPUT VOLTAGE (VOC)60 VDC MAX SHORT CIRCUIT CURRENT (ISC)14.50 ADC MAX OUTPUT CURRENT 15 ADC MAX OUTPUT VOLTAGE 60 VDC DC CONDUCTOR AMPACITY CALCULATIONS ARRAY STRING TO JBOX TO INVERTER AC CONDUCTOR AMPACITY CALCULATIONS BETWEEN INVERTER TO POINT OF CONNECTION AND/OR MAIN SERVICE PANEL EXPECTED WIRE TEMPERATURE (FREE AIR)39 CELSIUS AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 39 CELSIUS ADD 33°C FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF 72 CELSIUS TEMPERATURE CORRECTION FACTOR 0.91 TEMPERATURE CORRECTION FACTOR CEC TABLE 310.15 (B)(2)(A)0.91 # OF CURRENT CARRYING CONDUCTORS 2 # OF CURRENT CARRYING CONDUCTORS 2 CONDUIT FILL CORRECTION 1.00 1.00 (3 WIRES) .80 (4-6 WIRES) .70 (7-9 WIRES) .50 (10-20 WIRES) CONDUIT FILL CORRECTION 1.00 1.00 (3 WIRES) .80 (4-6 WIRES) .70 (7-9 WIRES) .50 (10-20 WIRES)CIRCUIT CONDUCTOR SIZE #10 AWG CIRCUIT CONDUCTOR SIZE #10 AWG CIRCUIT CONDUCTOR AMPACITY @ 90°40 AMPS CIRCUIT CONDUCTOR AMPACITY@75°35 AMPS INVERTER'S MAXIMUM AC OUPUT CURRENT 16 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY 18.75 AMPS (P401 ISC X 1.25) REQUIRED AC CONDUCTOR AMPACITY 20.00 AMPS DERATED AMPACITY OF CIRCUIT CONDUCTOR 31.85 AMPS DERATED AMPACITY OF CIRCUIT CONDUCTORS 36.40 AMPS NOTE: DERATED AMPACITY OF CIRCUIT CONDUCTOR MUST BE LARGER THAN REQUIRED CIRCUIT CONDUCTOR AMPACITY 31.85 >/= 18.75 NOTE: DERATED AMPACITY OF CIRCUIT CONDUCTOR MUST BE LARGER THAN REQUIRED CIRCUIT CONDUCTOR AMPACITY 36.40 >/= 20.00 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 REQUIRED SIGNAGE E3 PV ARRAY JBOX 1 5 INVERTER DC DISCO 3 4 4 AC DISCO M MAIN SERVICE PANEL 2 6 7 SEE PAGE E3.1 1 COMBINER BOX/CIRCUITS/ CONDUIT COMBINER BOX/ENCLOSURES/EMT ENCLOSURE WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRICAL SHOCK HAZARD CEC 706.15(C)(4) and CEC 690.13(B) CEC 110.27(C) & OSHA 1910.145(f)(7) WARNING! TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING I NSIDE PANEL 2 BUILDING/STRUCTURE CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN AC DISCONNECT INVERTER PV ARRAY UTILITY AC DISCONNECT NORTH CEC 705.10 & 690.56(A)(B) 3 EMT/CONDUIT RACEWAYS 4 CEC 690.31(O)(2) CEC 690.31(O)(2) SOLAR PV DC CIRCUIT PHOTOVOLTAIC POWER SOURCE DC DISCONNECT SOLAR PV SYSTEM EQUIPPED WI TH RAPI D SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS IFC 605.11.3.1(1) & CEC 690.56(C) RAPID SHUTDOWN FOR SOLAR PV SYSTEM CEC 690.56(C)(2)) PHOTOVOLTAIC DC DISCONNECT CEC 690.13(B) MAIN SERVICE DISCONNECT WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRICAL SHOCK HAZARD CEC 706.15(C)(4) and CEC 690.13(B) CEC 110.27(C) & OSHA 1910.145(f)(7) WARNING! TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING I NSIDE PANEL DO NOT DISCONNECT UNDER LOAD CEC 690.15 (B) & CEC 690.33(D)(2) WARNING !DUAL POWER SOURCE SECOND SOURCE I S PHOTOVOLTAIC SYSTEM CEC 705.12(C) & NEC 690.59 MAIN PHOTOVOLTAIC SYSTEM DISCONNECT PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT NORMAL OPERATING VOLTAGE A V 16 240 CEC 690.54 CEC 690.13(B) POWER S OURCE OUTPUT CONNECTI ON. DO NOT RELOCATE T HI S OVERCURRENT DEVI CE. WARNING! CEC 705.12 (B)(3)(2MAXIMUM DC VOLTAGE OF PV SYSTEM CEC 690.13(B) 480 V WARNING! THE DISCONNECTIO N O F THE GROUNDED CONDUCTOR(S) MAY RESULT I N OVERVOLTAGE ON THE EQUIPMENT CEC 690.31(E) WARNING! TER MIN A LS ON THE L IN E A ND LOAD SID ES MAY BE ENER GIZED IN THE OPEN POSITION ELECTR IC A L SHOCK HA ZARD DC VOLTAGE I S ALWAYS PRESENT W HEN SOLAR MODULES ARE EXP OSED TO SUNLIGHT CEC 690.13(B) PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT NORMAL OPERATING VOLTAGE A V 16 240 CEC 690.54 5 INVERTER 6 7AC DISCONNECT/BREAKER/ POINTS OF CONNECTION PHOTOVOLTAIC AC DISCONNECT WARNING! TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ELECTRICAL SHOCK HAZARD CEC 706.15(C)(4) and CEC 690.13(B) CEC 690.13(B) PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT NORMAL OPERATING VOLTAGE A V 16 240 CEC 690.54 WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICES EXCLUDING MAIN POWER SHALL NOT EXCEED AMPACITY OF BUSBAR. CEC 705.12(B)(3)(3) RAPID SHUTDOWN FOR SOLAR PV SYSTEM CEC 690.56(C)(2)) RAPID SHUTDOWN FOR SOLAR PV SYSTEM CEC 690.56(C)(2)) 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 REQUIRED SIGNAGE E3.1 MAIN SERVICE PANEL SOLAR ARRAYS INVERTER DIRECTORY PLACARD 6" 6" CAUTION DR I V E W A Y ADDRESS: 1919 N SPURGEON ST N S P U R G E O N S T 2 LABELING REQUIREMENTS 2022 CODE REFERENCE CEC 690.13(B) EACH PV SYSTEM DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IN THE OPEN (OFF) OR CLOSED (ON) POSITION AND BE PERMANENTLY MARKED "PV SYSTEM DISCONNECT" OR EQUIVALENT. ADDITIONAL MARKINGS SHALL BE PERMITTED BASED UPON THE SPECIFIC SYSTEM CONFIGURATION. FOR PV SYSTEM DISCONNECTING MEANS WHERE THE LINE AND LOAD TERMINALS MAY BE ENERGIZED IN THE OPEN POSITION.THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 110.21(B). CEC 690.56(C) BUILDINGS WITH PV SYSTEMS SHALL HAVE A PERMANENT LABEL LOCATED AT EACH SERVICE EQUIPMENT LOCATION TO WHICH THE PV SYSTEMS ARE CONNECTED OR AT AN APPROVED READILY VISIBLE LOCATION AND SHALL INDICATE THE LOCATION OF RAPID SHUTDOWN INITIATION DEVICES. CEC 690.31(B)(1) PV SYSTEM DC CIRCUIT CONDUCTORS SHALL BE IDENTIFIED AT ALL TERMINATION, CONNECTION, AND SPLICE POINTS BY COLOR CODING, MARKING TAPE, TAGGING, OR OTHER APPROVED MEANS. CONDUCTORS RELYING ON OTHER THAN COLOR CODING FOR POLARITY IDENTIFICATION SHALL BE IDENTIFIED BY AN APPROVED PERMANENT MARKING MEANS SUCH AS LABELING, SLEEVING, OR SHRINK-TUBING THAT IS SUITABLE FOR THE CONDUCTOR SIZE. CEC 690.31(D)(2) UNLESS LOCATED AND ARRANGED SO THE PURPOSE IS EVIDENT, THE FOLLOWING WIRING METHODS AND ENCLOSURES THAT CONTAIN PV SYSTEM DC CIRCUIT CONDUCTORS SHALL BE MARKED WITH THE WORDING PHOTOVOLTAIC POWER SOURCE OR SOLAR PV DC CIRCUIT BY MEANS OF PERMANENTLY AFFIXED LABELS OR OTHER APPROVED PERMANENT MARKING: (1) EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRING METHODS (2) COVERS OR ENCLOSURES OF PULL BOXES AND JUNCTION BOXES (3) CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE CONDUIT OPENINGS ARE UNUSED. THE LABELS OR MARKINGS SHALL BE VISIBLE AFTER INSTALLATION. ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 9.5 MM (3∕8 IN.) IN WHITE ON A RED BACKGROUND. LABELS SHALL APPEAR ON EVERY SECTION OF THE WIRING SYSTEM THAT IS SEPARATED BY ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR FLOORS. SPACING BETWEEN LABELS OR MARKINGS, OR BETWEEN A LABEL AND A MARKING, SHALL NOT BE MORE THAN 3 M (10 FT). LABELS REQUIRED BY THIS SECTION SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE THEY ARE INSTALLED. CEC 690.31(E) SOLIDLY GROUNDED BIPOLAR PV SYSTEMS SHALL BE CLEARLY MARKED WITH A PERMANENT, LEGIBLE WARNING NOTICE INDICATING THAT THE DISCONNECTION OF THE GROUNDED CONDUCTOR(S) MAY RESULT IN OVERVOLTAGE ON THE EQUIPMENT. CEC 690.33(D)(2)INTERRUPTION OF CIRCUIT. CONNECTORS SHALL BE A TYPE THAT REQUIRES THE USE OF A TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING.” CEC 690.52 ALTERNATING-CURRENT MODULES SHALL BE MARKED WITH IDENTIFICATION OF TERMINALS OR LEADS AND WITH IDENTIFICATION OF THE FOLLOWING RATINGS. CEC 690.53 A PERMANENT READILY VISIBLE LABEL INDICATING THE HIGHEST MAXIMUM DC VOLTAGE IN A PV SYSTEM, CALCULATED IN ACCORDANCE WITH 690.7, SHALL BE PROVIDED BY THE INSTALLER AT ONE OF THE FOLLOWING LOCATIONS: (1) DC PV SYSTEM DISCONNECTING MEANS (2) PV SYSTEM ELECTRONIC POWER CONVERSION EQUIPMENT (3) DISTRIBUTION EQUIPMENT ASSOCIATED WITH THE PV SYSTEM. CEC 690.54 ALL INTERACTIVE SYSTEM(S) POINTS OF INTERCONNECTION WITH OTHER SOURCES SHALL BE MARKED AS AN ACCESSIBLE LOCATION AT THE DISCONNECTING MEANS AS A POWER SOURCE AND WITH THE RATED AC OUTPUT CURRENT AND THE NOMINAL OPERATING AC VOLTAGE. CEC 690.55 THE PV SYSTEM OUTPUT CIRCUIT CONDUCTORS SHALL BE MARKED TO INDICATE POLARITY WHERE CONNECTED TO ENERGY STORAGE SYSTEMS. CEC 690.56(B) PLAQUES OR DIRECTORIES SHALL BE INSTALLED IN ACCORDANCE WITH 705.10 AND 712.10. CEC 690.56(C) THE TYPE OF PV SYSTEM IS SHOWN IN FIGURE 690.56 (C). CEC 690.56(C)(2) A RAPID SHUTDOWN INITIATION DEVICE SHALL HAVE A LABEL LOCATED ON OR NO MORE THAN 1 M (3 FT) FROM THE INITIATION DEVICE THAT INCLUDES THE FOLLOWING WORDING: RAPID SHUTDOWN FOR SOLAR PV SYSTEM THE LABEL SHALL BE REFLECTIVE, WITH ALL LETTERS CAPITALIZED AND HAVING A MINIMUM HEIGHT OF 9.5 MM (3∕8 IN.), IN WHITE ON RED BACKGROUND. CEC 690.59 PV SYSTEMS CONNECTED TO OTHER SOURCES SHALL BE INSTALLED IN ACCORDANCE WITH PARTS I AND II OF ARTICLE 705. CEC 705.12(B)(3)(3) THE SUM OF THE AMPERE RATINGS OF ALL OVERCURRENT DEVICES ON PANELBOARDS, BOTH LOAD AND SUPPLY DEVICES, EXCLUDING THE RATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR, SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. THE RATING OF THE OVERCURRENT DEVICEPROTECTING THE BUSBAR SHALL NOT EXCEED THE RATING OF THE BUSBAR. PERMANENT WARNING LABELSSHALL BE APPLIED TO DISTRIBUTION EQUIPMENT DISPLAYING THE FOLLOWING OR EQUIVALENT WORDING: WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICESHALL NOT EXCEED AMPACITY OF BUSBAR. CEC 705.12(D)SUITABLE FOR BACKFEED. FUSED DISCONNECTS, UNLESS OTHERWISE MARKED, SHALL BE CONSIDERED SUITABLE FOR BACKFEED. CEC 706.15(C) EACH ESS DISCONNECTING MEANS SHALL PLAINLY INDICATE WHETHER IT IS IN THE OPEN (ON) OR CLOSED (OFF) POSITION AND BE PERMANENTLY MARKED “ENERGY STORAGE SYSTEM DISCONNECT" THE DISCONNECTING MEANS SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE THE FOLLOWING: NOMINAL ESS AC VOLTAGE AND MAXIMUM ESS DC VOLTAGE AVAILABLE FAULT CURRENT DERIVED FROM THE ESS AN ARC-FLASH LABEL APPLIED IN ACCORDANCE WITH ACCEPTABLE INDUSTRY PRACTICE DATA CALCULATION WAS PERFORMED. CEC 110.27(C) ENTRANCES TO ROOMS OR OTHER GUARDED LOCATIONS THAT CONTAIN EXPOSED LIVE PARTS SHALL BE MARKED WITH CONSPICUOUS WARNING SIGNS FORBIDDING UNQUALIFIED PERSONS TO ENTER. CEC 705.10 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED AT A BUILDING SUPPLIED BY A STAND-ALONE SYSTEM AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN APPROVED READILY VISIBLE LOCATION. THE PLAQUE OR DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS FOR THE PREMISES OR BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. THE MARKING SHALL COMPLY WITH 110.21(B). CEC 705.12(C) EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM MULTIPLE SOURCES SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. CEC 705.12(B)(3)(3) PERMANENT WARNING LABELS SHALL BE APPLIED TO DISTRIBUTION EQUIPMENT DISPLAYING THE FOLLOWING OR EQUIVALENT WORDING: THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR. CEC 705.12(B)(3)(2) A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE INVERTER POWER SOURCE THAT DISPLAYS THE FOLLOWING OR EQUIVALENT WORDING: “WARNING: POWER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DRIVE.” CEC 705.10 & 690.56(A)(B) 705.10 IDENTIFICATION OF POWER SOURCES A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED AT EACH SERVICE EQUIPMENT LOCATION, OR AT AN APPROVED READILY VISIBLE LOCATION. THE PLAQUE OR DIRECTORY SHALL DENOTE THE LOCATION OF EACH POWER SOURCE DISCONNECTING MEANS FOR THE BUILDING OR STRUCTURE AND BE GROUPED WITH OTHER PLAQUES OR DIRECTORIES FOR OTHER ON-SITE SOURCES. THE PLAQUE OR DIRECTORY SHALL BE MARKED WITH THE WORDING "CAUTION: MULTIPLE SOURCES OF POWER." ANY POSTED DIAGRAMS SHALL BE CORRECTLY ORIENTED WITH RESPECT TO THE DIAGRAM'S LOCATION. THE MARKING SHALL COMPLY WITH 110.21(B). EXCEPTION: INSTALLATIONS WITH MULTIPLE CO-LOCATED POWER PRODUCTION SOURCES SHALL BE PERMITTED TO BE IDENTIFIED AS A GROUP(S). THE PLAQUE OR DIRECTORY SHALL NOT BE REQUIRED TO IDENTIFY EACH POWER SOURCE INDIVIDUALLY. MULTIPLE SOURCES OF POWER AC DISCO 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 MODULE DATA SHEET E4 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 MODULE CERTIFICATION E4.1 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 INVERTER DATA SHEET E5 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 INVERTER CERTIFICATION E5.1 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 OPTIMIZER DATA SHEET E6 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 S1 STANCHION DATA SHEET 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 S1.1 STANCHION ENGINEERING 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 RACKING DATA SHEET S2 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 RACKING ENGINEERING S3 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 RACKING ENGINEERING S3.1 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 RACKING ENGINEERING S3.2 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 RACKING ENGINEERING S3.3 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 GROUNDING DATA SHEET S4 1919 N Spurgeon St06/15/23 PROJECT NAME SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS JIMENEZ RESIDENCE 4.400 DC kW 4.048 KW CEC-AC RATING STRING INVERTER SYSTEM 1919 N SPURGEON ST, SANTA ANA, CA 92706 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP157692 DATE DESCRIPTION REVISION DATE DRAWN04-20-23 REVISION DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Ascend Energy CRCR106 & Business and Professions Code 5536.2 RACKING CERTIFICATION S5 FIRE CLASSIFICATION NOTES: Per the UL certification attached, the EVEREST Racking is certified for UL 2703 Class A rating. Hyperion HY-DH108P8-400 module also has a fire rating of Class A noted on Page E4- Module Data sheet. Module Certification in compliance with UL1703 and UL 61730-2 provided on Page E4.1 · UL1703 1 Scope 1.1 These requirements cover flat-plate photovoltaic modules and panels intended for installation on or integral with buildings, or to be freestanding (that is, not attached to buildings), in accordance with the National Electrical Code, NFPA 70, and Model Building Codes. 1.2 These requirements cover modules and panels intended for use in systems with a maximum system voltage of 1500 V or less. 1.3 These requirements also cover components intended to provide electrical connection to and mounting facilities for flat-plate photovoltaic modules and panels. 1.4 These requirements do not cover: a) Equipment intended to accept the electrical output from the array, such as power conditioning units (inverters) and batteries; b) Any tracking mechanism; c) Cell assemblies intended to operate under concentrated sunlight; d) Optical concentrators; or e) Combination photovoltaic-thermal modules or panels. · UL 61730-2 1 Scope The scope of IEC 61730-1 is also applicable to this part of IEC 61730. While IEC 61730-1 outlines the requirements of construction, this part of the standard lists the tests a PV module is required to fulfill for safety qualification. IEC 61730-2 is applied for safety qualification only in conjunction with IEC 61730-1. The sequence of tests required in this standard may not test for all possible safety aspects associated with the use of PV modules in all possible applications. This standard utilizes the best sequence of tests available at the time of its writing. There are some issues – such as the potential danger of electric shock posed by a broken PV module in a high voltage system – that should be addressed by the system design, location, restrictions on access and maintenance procedures. The objective of this standard is to provide the testing sequence intended to verify the safety of PV modules whose construction has been assessed by IEC 61730-1. The test sequence and pass criteria are designed to detect the potential breakdown of internal and external components of PV modules that would result in fire, electric shock, and/or personal injury. The standard defines the basic safety test requirements and additional tests that are a function of the PV module end-use applications. Test categories include general inspection, electrical shock hazard, fire hazard, mechanical stress, and environmental stress. The additional testing requirements outlined in relevant ISO standards, or the national or local codes which govern the installation and use of these PV modules in their intended locations, should be considered in addition to the requirements contained within this standard. 1919 N Spurgeon St06/15/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M -19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1919 North Spurgeon Street Santa Ana CA 92706 Titan Solar Power 1062072 Alex Aldama - Titan Solar Power 714-797-0616 5/25/23 capermitting@titansolarpower.com 1919 N Spurgeon St06/15/23 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 1919 N Spurgeon St06/15/23 Expedited Permit Process for PV Systems — Micro-Inverter2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. comp shingle Caulk K-2 Splice foot X, Crossrail 44-X 600.19 34 17.65 48 223.90 2.68 1919 N Spurgeon St06/15/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan Jimenez Residence 1919 N. Spurgeon St, Santa Ana CA 92706 4.400 DC Kw / 4.048 KW CEC-AC 1919 N Spurgeon St06/15/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT Jimenez Residence 1919 N. Spurgeon St, Santa Ana CA 92706 4.400 DC Kw / 4.048 KW CEC-AC HY-DH108P8-400 SE3800H-US NEMA 3R DG221URB 11 FREE N/A N/A #10 3 3/4" EMT 3/4" EMT #8 1 1919 N Spurgeon St06/15/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (P MAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram Jimenez Residence 1919 N. Spurgeon St, Santa Ana CA 92706 4.400 DC Kw / 4.048 KW CEC-AC HYPERION HY-DH108P8-400 12.90 31.01 37.07 13.79 30A 400 -0.27 SOLAREDGE SE3800H-US 3800 240 16 480 20 16 240 -7 39 1 1919 N Spurgeon St06/15/23