HomeMy WebLinkAbout2004 N Ross St - PlanMS P AC CB B A A A A A AA A A A A A B B B B B B B B B EV SP SITE PLAN LAYOUT (E) MAIN SERVICE PANEL WITH UTILITY METER (N)PV UTILITY AC DISCONNECT SWITCH (N)ENPHASE IQ COMBINER 4 APPROX 45' AC TRENCHED CONDUIT RUN ·ELECTRIC CODE:CEC 2019 ·FIRE CODE:CFC 2019 ·BUILDING CODE:CBC 2019 ·RESIDENTIAL CODE:CRC 2019 APPLICABLE CODES COVER PAGE T-01SCALE:1"=20'-0" POOL PHOTOVOLTAIC ARRAY ON DETACHED NON-HABITABLE STRUCTURE-02 ENGINEERING SCOPE OF WORK 1. ILLUMINE INDUSTRIES INC. HAS ONLY PROVIDED DRAFTING SERVICES FOR THE PERMIT DRAWINGS. NO ACTUAL ENGINEERING WORK, ENGINEERING REVIEW OR ENGINEERING. APPROVAL HAS BEEN CONDUCTED BY ILLUMINE INDUSTRIES INC UNLESS NOTED OTHERWISE. 2. WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE (STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT. DRAWINGS, HE/SHE: a. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN. b. IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN. c. HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN. GENERAL SYSTEM INFORMATION: SYSTEM SIZE: 8800W DC, 6380W AC, 7928W CEC AC MODULES: (22)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W INVERTER: (22)ENPHASE IQ8PLUS-72-2-US(240V)(SI-1), BRANCH DETAILS: 1X12, 1X10 MICRO INVERTER BRANCHES SCOPE OF WORK SHEET CATALOG INDEX NO. DESCRIPTION T-01 COVER PAGE S-01 MOUNTING DETAIL S-02 STRUCTURAL DETAIL E-01 SINGLE LINE DIAGRAM E-02 THREE LINE DIAGRAM E-03 ELECTRICAL CALCULATIONS PL-01 WARNING PLACARDS PL-02 SAFETY PLANS-1 PL-03 SAFETY PLANS-2 SS SPEC SHEET(S) 1.MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2.INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3.DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4.WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26. 5.ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6.ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8.THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9.ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10.PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING GENERAL NOTES BEATRICE RAYA - 8.800kW DC, 6.380kW AC, 7.928kW CEC AC VICINITY MAP 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 STRING CONFIGURATION BRANCH DETAILS A 12 MODULES B 10 MODULES FENCE 174'-10" 174'-10" 52' PROPERTY LINE PHOTOVOLTAIC ARRAY ON DETACHED NON-HABITABLE STRUCTURE-01 CONDUIT RUN TOTAL AREA OF ROOF (SQ.FT) 3910 TOTAL ARRAY AREA (SQ.FT) 464.6583 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%)11.88 2'-5" 44'-10" 20'-1" 1'-1" GATE GATE RESIDENCE APPROX 8' AC TRENCHED CONDUIT RUN DRIVE WAY N R O S S S T WALK WAY NOTE: PV SYSTEM TO BE INSTALLED ON DETACHED NON-HABITABLE STRUCTURE. DETACHED STRUCTURE-02 DETACHED STRUCTURE-01 (N)EV CHARGER (N) SUB PANEL Structural Only Signed: 11/10/2022 BLDG# 101113123 ISS 12/13/22 ELEC# 20178209 ISS 12/13/22 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown 2004 N Ross St 12/14/22 4 4 (E)200A CENTER FED MAIN PANEL UTILITY GRID (E ) 2 0 0 A M A I N BR E A K E R EXISTING 120/240V 1PH 60HZ METER#:SOUTHERN CALIFORNIA EDISON SCE-222013-489241M (N)125A SUB PANEL (N)35A PV BREAKER AT OPPOSITE END OF THE BUS BAR RELOCATED LOADS (N)60A AC DISCONNECT EATON DG222URB PV SYSTEM AC DISCONNECT SWITCH NON FUSED VISIBLE OPEN 60A, 120/240V 2P 4 15A 20A 20A AC COMBINER WITH ENPHASE ENVOY X-IQ-AM1-240-4 120/240 NEMA 3R INSTALL (2)20A PV 2P BREAKERS (N)ENPHASE IQ COMBINER 4 (ONLY FOR SOLAR, NO LOADS TO BE ADDED) (10)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W,MODULES WITH (10)ENPHASE IQ8PLUS-72-2-US(240V)(SI-1) (1) BRANCH OF (10) MICRO-INVERTERS (N)JUNCTION BOX 2A 1A DC CONDUCTORS AC CONDUCTORS (12)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W,MODULES WITH (12)ENPHASE IQ8PLUS-72-2-US(240V)(SI-1) (1) BRANCH OF (12) MICRO-INVERTERS (N)JUNCTION BOX 2 1 DC CONDUCTORS AC CONDUCTORS (N)EV CHARGER 5 (N)60A 2P BREAKER 3 (N)60A SUB FEEDER BREAKER AT OPPOSITE END OF THE BUS BAR SINGLE LINE DIAGRAM E-01 ELECTRICAL NOTES 1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.10(D). 2.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS TO CEC 240. 6.AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER CEC 250.122. 7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 690.31(A). 8.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON CEC 310.15(B)(2). 9.MAX. SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. 10.CONDUCTORS ARE SIZED PER CEC TABLE CEC 310.15(B)(16). SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 8800W, AC SYSTEM SIZE - 6380W, CEC AC RATING - 7928W 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1,1A NONE (2) 12AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 6AWG BARE COPPER 2,2A,3 1-1/4" SCH 40 PVC (BELOW GROUND) 3/4" SCH 80 PVC (ABOVE GROUND) (2) 10AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 4 3/4"EMT (2) 8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 5 3/4"EMT (2) 6 AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 NOTE: SUB PANEL RATING:125A, SUB FEEDER BREAKER RATING:60A 120% RULE: (125AX1.2)-60A=90A =>ALLOWABLE BACKFEED IS 90A OCPD CALCULATIONS: INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS =1.21x1.25x22=33.28 A =>PV BREAKER = 35A ALLOWABLE BACKFEED 90A =>35A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS. 2004 N Ross St 12/14/22 (E)200A CENTER FED MAIN PANEL UTILITY GRID (E ) 2 0 0 A M A I N BR E A K E R 4 (N)60A SUB FEEDER BREAKER AT OPPOSITE END OF THE BUS BAR (N)125A SUB PANEL (N)35A 2P PV BREAKER AT OPPOSITE END OF THE BUS BAR G N METER#:SOUTHERN CALIFORNIA EDISON SCE-222013-489241M N G 4 4 (N)60A AC DISCONNECT EATON DG222URB PV SYSTEM AC DISCONNECT SWITCH NON FUSED VISIBLE OPEN 60A, 120/240V 2P G 20A G AC COMBINER WITH ENPHASE ENVOY X-IQ-AM1-240-4 120/240 NEMA 3R INSTALL (2)20A PV 2P BREAKERS (ONLY FOR SOLAR, NO LOADS TO BE ADDED) (N)ENPHASE IQ COMBINER 4 15A 20A G G G (N)JUNCTION BOX G 2A 1A (12)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W MODULES WITH (12)ENPHASE IQ8PLUS-72-2-US(240V)(SI-1) (1) BRANCH OF (10) MICRO-INVERTERS G G G (N)JUNCTION BOX G 2 1 (1) BRANCH OF (12) MICRO-INVERTERS (12)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W MODULES WITH (12)ENPHASE IQ8PLUS-72-2-US(240V)(SI-1) 3 (N)EV CHARGER 5 (N)60A 2P BREAKER RELOCATED LOADS DC CONDUCTORS AC CONDUCTORS DC CONDUCTORS AC CONDUCTORS THREE LINE DIAGRAM E-02 ELECTRICAL NOTES 1.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.10(D). 2.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.10(C). 3.MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 4.ALL CONDUCTORS SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED. 5.BREAKER/FUSE SIZES CONFORMS TO CEC 240. 6.AC EQUIPMENT GROUNDING CONDUCTOR SIZED PER CEC 250.122. 7.AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 690.31(A). 8.AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON CEC 310.15(B)(2). 9.MAX. SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. 10.CONDUCTORS ARE SIZED PER CEC TABLE CEC 310.15(B)(16). THREE LINE DIAGRAM: DC SYSTEM SIZE - 8800W, AC SYSTEM SIZE - 6380W, CEC AC RATING - 7928W 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1,1A NONE (2) 12AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 6AWG BARE COPPER 2,2A,3 1-1/4" SCH 40 PVC (BELOW GROUND) 3/4" SCH 80 PVC (ABOVE GROUND) (2) 10AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 4 3/4"EMT (2) 8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1) 10AWG THHN/THWN-2 5 3/4"EMT (2) 6 AWG THHN/THWN-2 NONE (1) 10AWG THHN/THWN-2 NOTE: SUB PANEL RATING:125A, SUB FEEDER BREAKER RATING:60A 120% RULE: (125AX1.2)-60A=90A =>ALLOWABLE BACKFEED IS 90A OCPD CALCULATIONS: INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS =1.21x1.25x22=33.28 A =>PV BREAKER = 35A ALLOWABLE BACKFEED 90A =>35A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS. 2004 N Ross St 12/14/22 ELECTRICAL CALCULATIONS E-03 ELECTRICAL CALCULATIONS 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 MICRO INVERTER SPECIFICATIONS MODEL ENPHASE IQ8PLUS-72-2-US(240V)(SI- 1) POWER RATING 290W MAX OUTPUT CURRENT 1.21A CEC WEIGHTED EFFICIENCY 97% MAX NO OF MICRO INVERTERS/BRANCH 13 MAX DC VOLTAGE 60V MODULE SPECIFICATION MODEL HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W MODULE POWER @ STC 400W OPEN CIRCUIT VOLTAGE:Voc 45.30V MAX POWER VOLTAGE:Vmp 37.13V SHORT CIRCUIT CURRENT:Isc 11.14A MAX POWER CURRENT:Imp 10.77A ELECTRICAL CALCULATIONS AC WIRE SIZING CALCULATIONS BASED OF FOLLOWING EQUATIONS >> ·REQUIRED CONDUCTOR AMPACITY: INVERTER OUTPUT CURRENT X #OF INVERTERSXMAX CURRENT PER 690.8(A)(3)X125% PER 690.8(B)(2)(A) ·CORRECTED AMPACITY CALCULATIONS:AMPACITY X TEMPERATURE DERATE FACTOR X CONDUIT FILL DERATE = DERATED CONDUCTOR AMPACITY ·DERATED CONDUCTOR AMPACITY CHECK: MAX CURRENT PER 690.8(B)(2)(2) < DERATED CONDUCTOR AMPACITY AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION DERATED CONDUCTOR AMPACITY CHECK 1,1A 1.21 X 12 = 14.52 X 1.25 = 18.15A 30 X 0.87 X 1 =26.10A 18.15A <26.10A 2,2A,3 1.21 X 12 = 14.52 X 1.25 = 18.15A 40 X 0.87 X 1 =34.80A 18.15A <34.80A 4 1.21 X 22 = 26.62 X 1.25 = 33.28A 55 X 0.87 X 1 =47.85A 33.28A <47.85A 2004 N Ross St 12/14/22 2004 N Ross St 12/14/22 MSP AC CBEV SP WARNING PLACARDS PL-01 ! WARNING CAUTION: SOLAR CIRCUIT CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED LABEL LOCATION POINT OF INTERCONNECTION PER CODE: CEC 705.12(B)(2)(3)(b) ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION DC DISCONNECT,INVERTER [To be used when inverter is ungrounded] WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION CONDUIT, COMBINER BOX PER CODE: CEC690.31(G)(3) WARNING-ELECTRIC SHOCK HAZARD NO USER SERVICEABLE PARTS INSIDE CONTACT AUTHORIZED SERVICE PROVIDE FOR ASSISTANCE LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION PER CODE: CEC690.13(B) LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION PER CODE: CEC 690.54 LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. PER CODE: CEC690.31(G)(3) LABEL LOCATION POINT OF INTERCONNECTION PER CODE: CEC705.12(B)(3-4) AND 690.59 ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION PER CODE: CEC 690.13(B) LABEL LOCATION PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. PER CODE: CEC690.15 ,690.13(B) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! WARNING! SOLAR DISCONNECT RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 33.88 240 AMPS AC VAC PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION PER CODE: CEC690.56(C)(1)(a) ! POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN ! ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE. FASTENERS APPROVED BY THE LOCAL JURISDICTION CAUTION:MULTIPLE SOURCES OF POWER 2004 N ROSS ST, SANTA ANA, CA 92706 LABEL LOCATION SERVICE PANEL PER CODE: CEC 705.10 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SYSTEM UTILIZES MICRO-INVERTERS LOCATED UNDER EACH SOLAR MODULE WARNING PLACARDS 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 (E) UTILITY METER WITH MAIN SERVICE PANEL (N)PV UTILITY AC DISCONNECT SWITCH PHOTOVOLTAIC ARRAY ON DETACHED NON-HABITABLE STRUCTURE-2 PHOTOVOLTAIC ARRAY ON DETACHED NON-HABITABLE STRUCTURE-1 (N)ENPHASE IQ COMBINER 4 (N)EV CHARGER (N) SUB PANEL 2004 N Ross St 12/14/22 MS P AC CB EV SP SAFETY PLANS-1 PL-02 NOTES: 1. INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME. 2. INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST. 3. URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK. LOCATION OF NEAREST URGENT CARE FACILITY NAME: ADDRESS: PHONE NUMBER: SAFETY PLANS 2004 N ROSS ST, SANTA ANA, CA 92706 SAFETY PLANS-1 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 (N)PV UTILITY AC DISCONNECT SWITCH (N)ENPHASE IQ COMBINER 4 PHOTOVOLTAIC ARRAY ON DETACHED NON-HABITABLE STRUCTURE-02 PHOTOVOLTAIC ARRAY ON DETACHED NON-HABITABLE STRUCTURE-01 SYSTEM UTILIZES MICRO-INVERTERS LOCATED UNDER EACH SOLAR MODULE (N)EV CHARGER (E) UTILITY METER WITH MAIN SERVICE PANEL (N) SUB PANEL 2004 N Ross St 12/14/22 SAFETY PLANS-2 PL-03 SAFETY PLANS-2 NOTES: 1. INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME. 2. INSTALLERS SHALL UPDATE NAME ADDRESS AND PHONE NUMBER OF NEAREST. 3. URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING WORK. LOCATION OF NEAREST URGENT CARE FACILITY NAME: ADDRESS: PHONE NUMBER: SAFETY PLANS PRINT NAME INITIAL YES NO PERSONS COVERED BY THIS JOB SAFETY PLAN INITIAL YES OR NO INJURED AT WORK TODAY? UNDERGROUND DIG REQUIRED? YES ______ PERMIT #________________ 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2004 N Ross St 12/14/22 B A A A A A AA A A A A A B B B B B B B B B AERIAL VIEW MOUNTING DETAIL S-01 ALUMINIUM RAILS ARRAY MP-02 SCALE:1/8" = 1'-0" 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 1.STRUCTURAL ROOF MEMBER LOCATIONS ARE ESTIMATED AND SHOULD BE LOCATED AND VERIFIED BY THE CONTRACTOR WHEN LAG BOLT PENETRATION OR MECHANICAL ATTACHMENT TO THE STRUCTURE IS REQUIRED. 2.ROOFTOP PENETRATIONS FOR SOLAR RACKING WILL BE COMPLETED AND SEALED WITH APPROVED SEALANT PER CODE BY A LICENSED CONTRACTOR. 3.LAGS MUST HAVE A MINIMUM 2.5" THREAD EMBEDMENT INTO THE STRUCTURAL MEMBER. 4.ALL PV RACKING ATTACHMENTS SHALL BE STAGGERED BY ROW BETWEEN THE ROOF FRAMING MEMBERS AS NECESSARY. 5.ROOF MOUNTED STANDARD RAIL REQUIRES ONE THERMAL EXPANSION GAP FOR EVERY RUN OF RAIL GREATER THAN 40'. 6.ALL CONDUCTORS AND CONDUITS ON THE ROOF SHALL BE MINIMUM 2.5" ABOVE THE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 7.THE PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR BUILDING ROOF VENTS. INSTALLATION NOTES NOTE:PENETRATIONS ARE STAGGERED SITE INFORMATION - WIND SPEED: 95 MPH AND SNOW LOAD: 0 PSF SR. NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.)ROOF TYPE ATTACHMENT ROOF EXPOSURE FRAME TYPE FRAME SIZE FRAME SPACING MAX RAIL SPAN OVER HANG MP-01 180° 37° 5 105.6 COMPOSITION SHINGLE K2 EVERFLASH ECOMP KIT EXPOSED RAFTERS 2 X 6 2'-0" 6'-0" 2'-0" MP-02 360° 37° 5 105.6 COMPOSITION SHINGLE K2 EVERFLASH ECOMP KIT EXPOSED RAFTERS 2 X 6 2'-0" 6'-0" 2'-0" MP-03 270° 39° 6 126.7 COMPOSITION SHINGLE K2 EVERFLASH ECOMP KIT EXPOSED RAFTERS 2 X 6 2'-0" 6'-0" 2'-0" MP-04 90° 39° 6 126.7 COMPOSITION SHINGLE K2 EVERFLASH ECOMP KIT EXPOSED RAFTERS 2 X 6 2'-0" 6'-0" 2'-0" ARRAY MP-01 2'-7" 1'-6" 1'-6" 2'-5" 11" 11" 1'-7" 6' TOTAL AREA OF ROOF (SQ.FT) 3910 TOTAL ARRAY AREA (SQ.FT) 464.6583 TOTAL AREA OF ARRAY COVERED IN THE ROOF (%)11.88 11" 1'-6" 11"11" 1'-2" 1'-6" 8" ARRAY MP-04 ARRAY MP-03 STRING CONFIGURATION BRANCH DETAILS A 12 MODULES B 10 MODULES 1'-7" 2 X 6 RAFTERS@ 2'-0"SPACING Structural Only 2004 N Ross St 12/14/22 MODULE END CLAMPMID CLAMPMODULE STRUCTURAL DETAIL S-02 UPLIFT CALCULATIONS UPLIFT 13939.8 LBS PULL OUT STRENGTH 20910 LBS POINT LOADING 31 LBS MODULES DATA HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W MODULE DIMS 74"x41.1"x1.26" LAG SCREWS 5/16"x3.5":2.5"MIN EMBEDMENT MID-CLAMP AND END-CLAMP ANATOMY GROUNDING LUG MID CLAMP ASSEMBLY MODULE FRAME K2 RAIL MODULE TO MODULE & MODULE TO RAIL GROUNDING MID-CLAMP SCALE: NTS GROUNDING DETAILS K2 RAIL K2 STRUCTURAL RAIL CONNECTOR T-BOLT SCREW SCALE: NTS RAIL TO RAIL T-BOLT 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2 X 6 RAFTERS @2'-0" SPACING COMPOSITION SHINGLE ROOF MODULE 5/16" X 3.5" LAG SCREW 1 BOLT PER PENETRATION LOAD BEARING WALL SCALE:NTS ROOF FRAMING DETAILS ATTACHMENT DETAIL- K2 EVERFLASH ECOMP KIT K2 EVERFLASH ECOMP KIT SOLAR MODULE K2 CROSSRAIL 6" MAX FLASHING DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 22 48.5 1067.00 MID-CLAMP 36 0.300 10.80 END-CLAMP 16 0.310 4.96 RAIL LENGTH 147 0.560 82.32 SPLICE BAR 8 0.650 5.20 K2 EVERFLASH ECOMP KIT 34 1.45 49.30 TOTAL WEIGHT OF THE SYSTEM (LBS)1219.58 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)464.66 WEIGHT PER SQ. FT.(LBS)2.62 WEIGHT PER PENETRATION (LBS)35.87 5/16 HEX-BOLT STAINLESS STEEL 5/16" LAG SCREW 2.5" EMBEDMENT PILOT HOLE REQUIRED Structural Only 2004 N Ross St 12/14/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Titan Solar Power CA 1062072 Guillermo Vasquez 626-602-5493 capermitting@titansolarpower.com 2004 N Ross St 2004 N Ross St 12/14/22 MODULE SPEC SHEET SS-01 SPEC SHEET 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2004 N Ross St 12/14/22 INVERTER SPEC SHEET SS-02 SPEC SHEET 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2004 N Ross St 12/14/22 COMBINER CABINET SPEC SHEET SS-03 SPEC SHEET 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2004 N Ross St 12/14/22 MOUNT SPEC SHEET SS-04 SPEC SHEET 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2004 N Ross St 12/14/22 RAIL SPEC SHEET SS-05 SPEC SHEET 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2004 N Ross St 12/14/22 MPU SPEC SHEET SS-06 SPEC SHEET 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2004 N Ross St 12/14/22 MOUNT SPEC SHEET SS-07 SPEC SHEET 33.762753, -117.872883 APN: 002-10-305 CUSTOMER INFORMATION NAME:BEATRICE RAYA DATE:7/21/2022 SCALE:AS NOTED REV:D AHJ:CA-CITY OF SANTA ANA UTILITY:SOUTHERN CALIFORNIA EDISON PRN NUMBER:TPS-56928 DRAFTED BY: P.SANKET QC'ED BY: A.N.KRISHNAN PAPER SIZE:17"X11" ADDRESS:2004 N ROSS ST, SANTA ANA, CA 92706 ADDRESS: 525W, BASELINE RD MESA AZ,85210 LICENSE#'S CA:1062072 BL:010238 TSP NUMBER:TSP133481 2004 N Ross St 12/14/22 Code 2019 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 95 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 11/10/2022 RE: Structural Certification for Installation of Residential Solar BEATRICE RAYA:2004 N ROSS ST, SANTA ANA,CA 92706 Attn: To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition shingle roofing over roof plywood supported by 2X6 Rafters at 24 inches. The slope of the roof was approximated to be 37 and 39 degrees and the allowable maximum rafter span is 8 feet between supports. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Design Criteria projects@evengineersnet.com http://www.evengineersnet.com 2004 N Ross St 12/14/22 Structural Letter for PV Installation Date: 11/10/2022 Job Address: 2004 N ROSS ST SANTA ANA,CA 92706 Job Name: BEATRICE RAYA Job Number: 220808BR Scope of Work Table of Content Sheet 1 Cover 2 Attachment Uplift checks 3 Roof Framing Check 4 Seismic Check and Scope of work Engineering Calculations Summary Code 2019 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 95 mph Exposure C References NDS for Wood Construction Sincerely, Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. projects@evengineersnet.com http://www.evengineersnet.com 2004 N Ross St 12/14/22 Wind Load Cont. 95 mph ASCE 7-16 Figure 26.5-1B C 1.0 ASCE 7-16 Sec 26.8.2 0.93 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 1.00 ASCE 7-16 Table 26.9-1 18.15 psf 37.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1) Zone(2r) Zone(2e)Zone(3) Fig. 30-3-2 GCp=-1.9 -2.2 -1.6 -1.8 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-41.39 -47.92 -34.85 -39.21 GCp=0.7 Figure 30.3-2 P=qh(GCp)(γE)(γa)=11.44 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing= 6 ft 5/16"X3.5"Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity= 760 lbs Zone Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1) 6 16.5 329.6 238.2 Zone(2r) 6 16.5 378.1 238.2 Zone(2e) 6 16.5 281.1 238.2 Zone(3) 6 16.5 313.4 238.2 Conservative Max= 378.1 < 760 CONNECTION IS OK 2.Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1.Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration Risk Category = KZ = Kd = Ke = projects@evengineersnet.com http://www.evengineersnet.com 2004 N Ross St 12/14/22 Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg= 0 psf Ct = 1.1 Ce = 0.9 Is = 1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1) 0 plf Max Length, L = 8.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT = 24 in Dr = 10 psf 20 plf PvDL = 3 psf 18 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL= 48 plf Mdown= 386 lb-ft Mallowable = Sx x Fb' (wind)= 975 lb-ft > 386 lb-ft OK Load Case: DL+S Ps+ Ppvcos(θ)+PDL= 38 plf Mdown= 304 lb-ft Mallowable = Sx x Fb' (wind)= 975 lb-ft > 304 lb-ft OK Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL= 51.7 plf Max Moment, Mu= 414 lb-ft Mallowable = Sx x Fb' (wind)= 1357 lb-ft > 414 lb-ft OK Pv max Shear= 238.2 lbs Shear, Vu=wL/2+Pv Point Load = 390 lbs Max Shear, Vu=wL/2+Pv Point Load = 390 lb Member Capacity DF-L No.2 2X6 CL CF Ci Cr KF φ λ Fb = 900 psi 1.0 1.3 1.0 1.15 2.54 0.85 0.8 1346 psi Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin = 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 5.5 in Width, b = 1.5 in Cross-Sectonal Area, A = 8.25 in2 Moment of Inertia, Ixx = 20.7969 in4 Section Modulus, Sxx = 7.5625 in Allowable Moment, M all = Fb'Sxx = 847.9 lb-ft DCR=Mu/Mall = 0.40 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A = 990.0 lb DCR=Vu/Vall = 0.39 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 2004 N Ross St 12/14/22 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 11.88% Dpv and Racking 3 psf Average Total Dead Load 10.4 psf Increase in Dead Load 1.4%OK The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - BEATRICE RAYA. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com 2004 N Ross St 12/14/22 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 2004 N Ross St 12/14/22 Expedited Permit Process for PV Systems — Micro-Inverter2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? Xl Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. YES X X x caulk K2 K2 systems 44X rails with splice foot X attachment1219.58 34 35.87 72 464.66 2.62 2004 N Ross St 12/14/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Micro-Inverter Site Plan                                                        BEATRIC RAYA RESIDENCE 2004 N ROSS ST, SANTA ANA, CA 6.380kW AC 2004 N Ross St 12/14/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W IQ8PLUS-72-2-US(240V)(SI-1) 2IHD5-2 HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W X 12 ENPHASE ENVOY X-IQ-AM1-240-4 N/A EATON DG222URB EXISTING X #6 BARE 1X X 10 2 PVC 125"/.75" X 10 1 X 8 2 EMT 10X 1 BEATRIC RAYA RESIDENCE 2004 N ROSS ST, SANTA ANA, CA 6.380kW AC 2004 N Ross St 12/14/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____ oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ 400W 10.77 37.13 45.3 11.14 20 400W 37.13V X -.27 ENPHASE IQ8PLUS-72-2-US(240V)(SI-1) 440 300 1.21 240 1.5 240 33.88 -40 60 X X 1 X 2004 N Ross St 12/14/22