HomeMy WebLinkAbout2050 W Martha Ln - PlanGENERAL NOTES PV-2.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:7/31/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. GENERAL NOTES GENERAL NOTES 1. MODULES ARE LISTED UNDER UL 1703 AND CONFORM TO THE STANDARDS. 2. INVERTERS ARE LISTED UNDER UL 1741 AND CONFORM TO THE STANDARDS. 3. DRAWINGS ARE DIAGRAMMATIC, INDICATING GENERAL ARRANGEMENT OF THE PV SYSTEM AND THE ACTUAL SITE CONDITION MIGHT VARY. 4. WORKING CLEARANCES AROUND THE NEW PV ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC CODE. 5. ALL GROUND WIRING CONNECTED TO THE MAIN SERVICE GROUNDING IN MAIN SERVICE PANEL/ SERVICE EQUIPMENT. 6. ALL CONDUCTORS SHALL BE 600V, 75°C STANDARD COPPER UNLESS OTHERWISE NOTED. 7. WHEN REQUIRED, A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 8. THE SYSTEM WILL NOT BE INTERCONNECTED BY THE CONTRACTOR UNTIL APPROVAL FROM THE LOCAL JURISDICTION AND/OR THE UTILITY. 9. ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREES, WIRES OR SIGNS. 10. PV ARRAY COMBINER/JUNCTION BOX PROVIDES TRANSITION FROM ARRAY WIRING TO CONDUIT WIRING EQUIPMENT LOCATION: 11. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY CEC CODE. 12. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY CEC CODE AND CEC TABLES. 13. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC CODE. 14. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 15. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO CEC APPLICABLE CODES. 16. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE . STRUCTURAL NOTES: 17. RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 18. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 19. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 20. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 21. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES: 22. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 23. CONDUCTORS SIZED ACCORDING TO CEC CODE. 24. DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 25. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [CEC CODE]. INTERCONNECTION NOTES: 26. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [CEC CODE] 27. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120% OF BUSBAR RATING [CEC CODE]. 28. WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, PV DEDICATED BACKFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [CEC CODE]. 29. AT MULTIPLE PV OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVER CURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVER CURRENT DEVICE MAY BE EXCLUDED ACCORDING TO CEC CODE. 30. FEEDER TAP INTER CONNECTION (LOAD SIDE) ACCORDING TO CEC CODE. 31. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO CEC CODE WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH CEC CODE. 32. BACK FEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [CEC CODE]. GROUNDING NOTES: 33. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 34. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO CEC CODE AND MINIMUM CEC TABLE. 35. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD. 36. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC CODE AND MICRO INVERTER MANUFACTURER'S INSTRUCTIONS. 37. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 38. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 39. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [CEC CODE] 40. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC CODE AND NEC CODE THROUGH . IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC CODE AND AHJ. 41. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC CODE IN GENERAL AND CEC CODE SPECIFICALLY. 42. DISCONNECTION AND OVER-CURRENT PROTECTION NOTES. 43. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 44. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 45. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 10 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [CEC CODE]. LOCATION OF LABEL ACCORDING TO AHJ. 46. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC CODE. 47. MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH CEC CODE. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC CODE AND UL1699B. Structural Only Bldg#: 101119362 Elec#: 20182863 Approvals: Elec: M Smith ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 2050 W Martha Ln 9/16/2024 MSP AC CB BTBT SP RSDINV BTBT AC CL AC IQ SITE PLAN-1 PV-1.0 HAVERSTICK, CHIAKI - 10.665kW DC, 7.830kW AC, 9.762kW CEC AC, 20kWH STORAGE SYSTEM SITE PLAN-1 PV-1.0 A SITE PLAN-1 SCALE: 1/16" = 1'-0" ELECTRIC CODE CEC 2022 FIRE CODE CFC 2022 RESIDENTIAL CODE CRC 2022 BUILDING CODE CBC 2022 WIND SPEED 94 MPH SNOW LOAD 0 PSF GENERAL INFORMATION PV-1.0 A1 VICINITY MAP SCALE: NTS CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:7/31/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. INDEX INDEX NO.DESCRIPTION SITE PLAN-1 SITE PLAN-2 GENERAL NOTES MOUNTING DETAILS STRUCTURAL DETAILS SINGLE LINE DIAGRAM ELECTRICAL CALCULATION MAIN SERVICE PANEL SCHEDULE BACKUP LOAD PANEL SCHEDULE WARNING PLACARDS MODULE SPEC SHEET PV-1.0 PV-1.1 PV-2.0 S-1.0 S-1.1 E-1.0 E-1.1 E-1.2 E-1.3 E-1.4 PD-1.0 INVERTER SPEC SHEET COMBINER SPEC SHEET RACKING SPEC SHEET MOUNT SPEC SHEET GROUNDING SPEC SHEET INTEGRATED GROUNDING SPEC SHEET FIRE RATING SPEC SHEET ENPHASE IQ SYSTEM CONTROLLER 2 SPECSHEET BATTERY SPEC SHEET PD-1.1 PD-1.2 PD-1.3 PD-1.4 PD-1.5 PD-1.6 PD-1.7 PD-1.8 PD-1.9 - (E) (15) 250W MODULES - (N) (27) CANADIAN SOLAR CS3N-395MS LEGEND: 3' FIRE SETBACK 3' FIRE SETBACK CONDUIT RUN 24' AC TRENCHED CONDUIT RUN (E) MAIN SERVICE PANEL (EXTERIOR)(E) 125A SUB PANEL (EXTERIOR) (E) PV INVERTER (EXTERIOR) (N) ENPHASE IQ COMBINER 5C (EXTERIOR) (N) ENPHASE IQ SYSTEM CONTROLLER 3G (EXTERIOR) (N) ENPHASE IQ BATTERY 5P-1P-NA-2 (EXTERIOR) (N) ENPHASE IQ BATTERY 5P-1P-NA -1 (EXTERIOR) (E) PHOTOVOLTAIC ARRAY ON THE ROOF (N) PHOTOVOLTAIC ARRAY ON THE ROOF GARAGE ADU MAIN HOUSE 17 ' - 6 " 19'-7" 35'- 8 " 10'- 8 " (E) AC DISCONNECT (EXTERIOR) PV SYSTEM TO BE INSTALLED ON DETACHED NON-HABITABLE STRUCTURE24 ' 19' 19' 16' AC TRENCHED CONDUIT RUN (N) ENPHASE RAPID SHUTDOWN SWITCH (EXTERIOR) (N) ENPHASE IQ BATTERY 5P-1P-NA-4 (EXTERIOR) (N) ENPHASE IQ BATTERY 5P-1P-NA-3 (EXTERIOR) (N) BATTERY DISCONNECT (EXTERIOR) (N) AC DISCONNECT (EXTERIOR) (N) BACKUP LOAD PANEL (EXTERIOR) B 8' GROUND ROD #6AWG BARE COPPER 8' GROUND ROD #6AWG BARE COPPER B Signed: 8/5/2024 Structural Only 2050 W Martha Ln 9/16/2024 MSPAC CB BTBT SP RSDINV BTBT AC CL AC IQ SITE PLAN-2 PV-1.1 HAVERSTICK, CHIAKI - 10.665kW DC, 7.830kW AC, 9.762kW CEC AC, 20kWH STORAGE SYSTEM SITE PLAN-2 PV-1.1 A SITE PLAN-2 SCALE: 1"=20'-0" CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:7/31/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. 12 1 ' 125'-9" 19 ' 106 ' - 7 " 133'-10" 2'-3" 22'-11" 1'-4" DETACHED STRUCTURE-1 DETACHED STRUCTURE-2 POOL (N) PHOTOVOLTAIC ARRAY ON THE ROOF (E) PHOTOVOLTAIC ARRAY ON THE ROOF DRI V E W A Y WA L K W A Y W MARTHA LN GARAGE PROPERTY LINE ADU MAIN HOUSE 48'-11" Structural Only 2050 W Martha Ln 9/16/2024 MOUNTING DETAILS S-1.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:7/31/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. S-1.0 B MOUNTING DETAILS SCALE: 1/16" = 1'-0" UPLIFT CALCULATIONS UPLIFT 17748.7 LBS PULL OUT STRENGTH 30750 LBS POINT LOADING 27 LBS MODULES DATA CANADIAN SOLAR CS3N-395MS MODULE DIMS 76.4"x41.3"x1.38" LAG SCREWS 5/16"x3":2.5"MIN EMBEDMENT AERIAL VIEW SITE INFORMATION SR.NO AZIMUTH PITCH NO. OF MODULES ARRAY AREA (SQ. FT.)ROOF TYPE ATTACHMENT ROOF EXPOSURE FRAME TYPE FRAME SIZE FRAME SPACING MAX RAIL SPAN OVER HANG MP-01 157°22°3 65.7 COMPOSITION SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0"2'-0" MP-02 151°18°10 219.1 COMPOSITION SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 4 2'-0"6'-0"2'-0" MP-03 225°18°5 109.6 COMPOSITION SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 12 1'-4"5'-4"2'-0" MP-04 315°18°9 197.2 COMPOSITION SHINGLE FLASH FOOT ATTIC RAFTERS 2 X 12 1'-4"5'-4"2'-0" DEAD LOAD CALCULATIONS BOM QUANTITY LBS/UNIT TOTAL WEIGHT (LBS) MODULES 27 49.6 1339.20 MID-CLAMP 40 0.050 2.00 END-CLAMP 28 0.050 1.40 RAIL LENGTH 209 0.680 142.12 SPLICE BAR 10 0.360 3.60 FLASH FOOT 50 1.35 67.50 MICRO-INVERTER 27 2.38 64.26 TOTAL WEIGHT OF THE SYSTEM (LBS)1620.08 TOTAL ARRAY AREA ON THE ROOF (SQ. FT.)591.62 WEIGHT PER SQ. FT.(LBS)2.74 WEIGHT PER PENETRATION (LBS)32.40 MINIMUM FIRE ACCESS PATHWAYS PER CFC 2022 RIDGE TO ARRAY: 3'-0" EAVE TO ARRAY : 3'-0" HIP/VALLEY W/ ADJACENT ARRAY: 1'-6" EACH SIDE HIP/VALLEY W/O ADJACENT ARRAY: 0'-0" NOTE: INSTALLER TO VERIFY RAFTER SIZE, SPACING AND SLOPED SPANS, AND NOTIFY ANY DISCREPANCIES BEFORE PROCEEDING. FIRE SETBACK 6' 3' 3' ARRAY MP-01 ALUMINIUM RAILS 2 X 4 RAFTERS@ 2'-0" SPACING ARRAY MP-02 2 X 12 RAFTERS@ 1'-4" SPACING ARRAY MP-03 3'3' 5'- 4 " ARRAY MP-04 Structural Only 2050 W Martha Ln 9/16/2024 STRUCTURAL DETAILS S-1.1 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. 5/16 HEX-BOLT STAINLESS STEEL 5/16" HANGER BOLT 2.5" EMBEDMENT PILOT HOLE REQUIRED (E)COMPOSITION SHINGLE ROOF IRONRIDGE FLASHFOOT IRONRIDGE RAIL PV MODULE (E) BUILDING STRUCTURE ATTACHMENT DETAIL- FLASH FOOT ROOF FRAMING DETAIL MID-CLAMP & END CLAMP DETAIL GROUNDING DETAILS MID CLAMP ASSEMBLY MODULE FRAME RAIL GROUNDING MID-CLAMP SCALE: NTS MODULE TO MODULE & MODULE TO RAIL GROUNDING RAIL TO RAIL IRON RIDGE RAIL INTERNAL SPLICE SELF-DRILLING SCREW SCALE: NTS T BOLT SCALE: NTS PV MODULE IRONRIDGE RAIL IRONRIDGE STOPPER SLEEVE END CLAMP PV MODULE IRONRIDGE RAIL MID CLAMP SCALE: NTS SCALE: NTS FLASHFOOT SOLAR MODULE RAIL 6" MAX 2 X 4 RAFTERS@2'-0" SPACING LOAD BEARING WALL FLASHFOOT SOLAR MODULE RAIL 6" MAX 2 X 12 RAFTERS@1'-4" SPACING LOAD BEARING WALL SCALE: NTS MP-01 & MP-02 MP-03 & MP-04 SCALE: NTS Structural Only 2050 W Martha Ln 9/16/2024 7 (E)200A MAIN BREAKER M 125A 2P BREAKER EXISTING 120/240V 1PH 60HZ UT I L I T Y GR I D (E)225A END FED MAIN PANEL (N)JUNCTION BOX OR EQUIV (N)JUNCTION BOX OR EQUIV (N)JUNCTION BOX OR EQUIV (N)(13)ENPHASE IQ8PLUS-72-2-US(240V,1PH) WITH (13)CANADIAN SOLAR CS3N-395MS MODULES (1) BRANCH OF (13) MICRO-INVERTERS(13 MODULES) (N)CANADIAN SOLAR CS3N-395MS, 395W MODULES (N)(11)ENPHASE IQ8PLUS-72-2-US(240V,1PH) WITH (11)CANADIAN SOLAR CS3N-395MS MODULES (1) BRANCH OF (11) MICRO-INVERTERS(11 MODULES) (10 MODULES IN EMT & 1 MODULE IN PVC) (N)CANADIAN SOLAR CS3N-395MS, 395W MODULES (N)(3)ENPHASE IQ8PLUS-72-2-US(240V,1PH) WITH (3)CANADIAN SOLAR CS3N-395MS MODULES (1) BRANCH OF (3) MICRO-INVERTERS(3 MODULES) (N)CANADIAN SOLAR CS3N-395MS, 395W MODULES 20A 20A 20A (N)200A AC DISCONNECT AC DISCONNECT NON FUSED 200A, 120/240V, 2P (E)125A SUB PANEL MAIN LUG WIRELESS COMMS AUXILIARY CONTACT NO1NO2NO1 NO2NO3 70A (N) ENPHASE IQ SYSTEM CONTROLLER 3G 70A (N)ENPHASE IQ BATTERY 5P-1P-NA, 5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY INVERTERS STORAGE SYSTEM-1 3A WIRELESS WIFI/CELLULAR ENLIGHTEN CLOUD TERTIARY CONTROL, API INTERFACE,OVER-THE-AIR FIRMWARE UPGRADE 5 MAIN LUG WIRELESS GENERATOR RESERVED FOR FUTURE USE (GENERATOR) ENPHASE RAPID SHUTDOWN SWITCH 6 (N)125A BACKUP LOAD PANEL 100A (N)ENPHASE IQ BATTERY 5P-1P-NA, 5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY INVERTERS STORAGE SYSTEM-2 AC COMBINER WITH ENPHASE IQ GATEWAY X-IQ-AM1-240-5C 120/240 NEMA 3R INSTALL (3)20A PV 2P BREAKERS (ONLY FOR SOLAR NO LOAD TO BE ADDED) (N)ENPHASE IQ COMBINER 5C WITH IQ GATEWAY (N)ENPHASE IQ BATTERY 5P-1P-NA, 5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY INVERTERS STORAGE SYSTEM-3 (N)ENPHASE IQ BATTERY 5P-1P-NA, 5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY INVERTERS STORAGE SYSTEM-4 (N)100A BATTERY DISCONNECT BATTERY DISCONNECT NON FUSED 100A, 120/240V, 2P 3A ADU ADU & GARAGE MAIN HOUSE 50A 20A 20A 100A TO GARAGE SUB PANEL TO FRIDGE TO BEDROOM (E) 125A SUB PANEL SUPPLYING ADU APPROX. 1' 7 (E)GROUND ELECTRODE 8' GROUNDING ROD #6 AWG BARE COPPER 8' GROUNDING ROD #6 AWG BARE COPPER 4 E 40/20 QUAD BREAKER IQ GATEWAY 12 1A2A 1B2B 20A AC DC DC DISCO (E) POWER ONE INVERTER 3.0 (E)JUNCTION BOX OR EQUIV (E) (15) 250W MODULES (E) (15) MODULES G EE 20A INSTALL (1)(N)50A PV 2P BREAKERS AND (1)(E)20A PV 2P BREAKERS (N)100A LOAD CENTER 50A E 3 (N)30A AC DISCONNECT AC DISCONNECT NON FUSED 30A, 120/240V, 2P E 8 APPROX. 1' NOTE: 1. MICRO INVERTERS ARE UL1741 RATED 2. EACH MICRO INVERTER IS RAPID SHUTDOWN COMPLIANT SINGLE LINE DIAGRAM E-1.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:9/6/2024 REV:C CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. SINGLE LINE DIAGRAM: DC SYSTEM SIZE - 10665W, AC SYSTEM SIZE - 7830W, CEC AC SYSTEM SIZE - 9762W, STORAGE SYSTEM-20000WH NOTE: 1. NEW SERVICE PANEL MUST BE COMBINATION/ALL-IN-ONE, AND METER AND MAIN CANNOT BE SEPARATE. 2. LISTED COMBINATION OVERHEAD AND UNDERGROUND FEED SERVICE BOXES REQUIRED. NOTE: 200A SERVICE REQUIRES A MINIMUM 4 AWG CONDUCTOR TO 10' OF UNDERGROUND METAL WATER PIPE ELECTRODE. BOND ON THE INSIDE/OUTSIDE WITHIN FIRST 5' OF WHERE THE WATER ENTERS THE BUILDING. AN ADDITIONAL CONNECTION UFER OR 2 NEW RODS IS NEEDED - LOCATED 6' FROM OTHER ELECTRODES. WATER PIPE MAY NOT BE USED TO BOND ANY ELECTRODES UNLESS BURIED OR ENCASED, ELECTRODE CONNECTIONS MUST BE ACCESSIBLE. NOTE: PCS CONTROLLED CURRENT SETTINGS: 180A C PLANCHECK NOTE: Per Site Plan Sheet PV-1.0, a grounding electrode conductor (GEC) system must be installed at the two separate buildings--the ADU and the Garage. If there is already a GEC system present, a new one is not required. At these separate buildings, the GEC system is bonded to the PV panel ground and the EGC of the building (as in a subpanel for the ADU). The neutrals, EGCs and the GEC system are all NOT bonded together anywhere but at the service disconnect at the main meter panel. CEC 690.47, 250.24(A)(1), 250.24(B), 250.32(A,B) 2050 W Martha Ln 9/16/2024 ELECTRICAL CALCULATION E-1.1 ELECTRICAL CALCULATION CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:9/6/2024 REV:C CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. MODULE SPECIFICATION MODEL CANADIAN SOLAR CS3N-395MS MODULE POWER @ STC 395W OPEN CIRCUIT VOLTAGE:Voc 44.3V MAX POWER VOLTAGE:Vmp 37V SHORT CIRCUIT CURRENT:Isc 11.44A MAX POWER CURRENT:Imp 10.68A MICRO INVERTER SPECIFICATIONS MODEL ENPHASE IQ8PLUS-72-2-US(240V,1PH) POWER RATING 290W MAX OUTPUT CURRENT 1.21A CEC WEIGHTED EFFICIENCY 97% MAX NO OF MICRO INVERTERS/BRANCH 13 MAX DC VOLTAGE 60V ELECTRICAL NOTES: 1. MAXIMUM DC/AC VOLTAGE DROP SHALL BE NO MORE THAN 2%. 2. BREAKER/FUSE SIZES CONFORMS TO CEC 240.6 CODE SECTION. 3. AC GROUNDING ELECTRODE CONDUCTOR SIZED PER CEC 250.66. 4. AMBIENT TEMPERATURE CORRECTION FACTOR IS BASED ON CEC 690.31(C). 5. AMBIENT TEMPERATURE ADJUSTMENT FACTOR IS BASED ON CEC 310.15(B)(2)(C). 6. AX. SYSTEM VOLTAGE CORRECTION IS PER CEC 690.7. 7. CONDUCTORS ARE SIZED PER WIRE AMPACITY TABLE CEC 310.16. 8. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER CEC 310.0(D). 9. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER CEC 310.8(C). CONDUIT SCHEDULE TAG ID CONDUIT SIZE CONDUCTOR NEUTRAL GROUND 1 NONE (2) 12 AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 6 AWG BARE COPPER 1A NONE (2) 12 AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 6 AWG BARE COPPER 1B NONE (2) 12 AWG ENPHASE Q CABLE PER BRANCH CIRCUIT NONE (1) 6 AWG BARE COPPER 2 (E) 1-1/4" SCH 40 PVC (BELOW GROUND) 3/4" SCH 80 PVC (ABOVE GROUND (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 2A 3/4" SCH 40 PVC (BELOW GROUND) 3/4" SCH 80 PVC (ABOVE GROUND (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 2B 3/4"EMT OR EQUIV (2) 10 AWG THHN/THWN-2 NONE (1) 10 AWG THHN/THWN-2 3 3/4"EMT OR EQUIV (2) 8 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 3A 3/4"EMT OR EQUIV (2) 4 AWG THHN/THWN-2 NONE (1) 8 AWG THHN/THWN-2 4 1"EMT OR EQUIV (2) 4 AWG THHN/THWN-2 (1) 4 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 5 1"EMT OR EQUIV (2) 3 AWG THHN/THWN-2 (1) 3 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 6 3/4"EMT OR EQUIV (2) 12 AWG THHN/THWN-2 NONE NONE 7 1-1/4"EMT OR EQUIV (2) 1 AWG THHN/THWN-2 (1) 1 AWG THHN/THWN-2 (1) 6 AWG THHN/THWN-2 8 1-1/4"EMT OR EQUIV (2) 8 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (2) 3 AWG THHN/THWN-2 (1) 3 AWG THHN/THWN-2 (1) 8 AWG THHN/THWN-2 AC WIRE CALCULATIONS:- MATERIAL:COPPER & TEMPERATURE RATING:90°C TAG ID REQUIRED CONDUCTOR AMPACITY CORRECTED AMPACITY CALCULATION TERMINAL RATING CHECK DERATED CONDUCTOR AMPACITY CHECK 1 1.21 X 13 =15.73 X 1.25 =19.66A 30 X 0.96 X 1 =28.80A 19.66A <25A 19.66A <28.80A 1A 1.21 X 11 =13.31 X 1.25 =16.64A 30 X 0.96 X 1 =28.80A 16.64A <25A 16.64A <28.80A 1B 1.21 X 3 =3.63 X 1.25 =4.54A 30 X 0.96 X 1 =28.80A 4.54A <25A 4.54A <28.80A 2 1.21 X 13 =15.73 X 1.25 =19.66A 40 X 0.96 X 1 =38.40A 19.66A <35A 19.66A <38.40A 2A 1.21 X 11 =13.31 X 1.25 =16.64A 40 X 0.96 X 1 =38.40A 16.64A <35A 16.64A <38.40A 2B 1.21 X 3 =3.63 X 1.25 =4.54A 40 X 0.96 X 1 =38.40A 4.54A <35A 4.54A <38.40A 3 1.21 X 27 =32.67 X 1.25 =40.84A 55 X 0.96 X 1 =52.80A 40.84A <50A 40.84A <52.80A 3A 16 X 4 =64.00 X 1.00 =64.00A 95 X 0.96 X 1 =91.20A 64.00A <85A 64.00A <91.20A 4 70 X 1 =70.00 X 1.00 =70.00A 95 X 0.96 X 1 =91.20A 70.00A <85A 70.00A <91.20A 5 100 X 1 =100.00 X 1.00 =100.00A 115 X 0.96 X 1 =110.40A 100.00A ≤100A 100.00A <110.40A 7 125 X 1 =125.00 X 1.00 =125.00A 145 X 0.96 X 1 =139.20A 125.00A <130A 125.00A <139.20A ELECTRICAL CALCULATION OCPD CALCULATIONS: MAIN PANEL RATING:225A, MAIN BREAKER RATING:200A 120% RULE: (225AX1.2)-200A=70A =>ALLOWABLE BACKFEED IS 70A INVERTER OVERCURRENT PROTECTION= INVERTER O/P I X CONTINUOUS LOAD(1.25)X #OF INVERTERS =(1.21x1.25x27)+(16x4)+20=124.84 A =>PV BREAKER = 70A ALLOWABLE BACKFEED 70A =>70A PV BREAKER THE DESIGNED INTERCONNECTION MEETS THE 705.12(B)(2) REQUIREMENTS C 2050 W Martha Ln 9/16/2024 MSPAC CB BTBT SP RSDINV BTBT AC CL AC IQ E-1.2 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:7/31/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. ALL PLACARDS SHALL BE OF WEATHER PROOF CONSTRUCTION, BACKGROUND ON ALL PLACARDS SHALL BE RED WITH WHITE LETTERING U.O.N. PLACARD SHALL BE MOUNTED DIRECTLY ON THE EXISTING UTILITY ELECTRICAL SERVICE.FASTENERS APPROVED BY THE LOCAL JURISDICTION NOTE:ALL SIGNAGE CANNOT BE HAND WRITTEN CEC 110.21 WARNING PLACARDS SYSTEM UTILIZES MICRO-INVERTERS LOCATED UNDER SOLAR MODULE WARNING PLACARDS WARNING CAUTION: SOLAR CIRCUIT LABEL LOCATION POINT OF INTERCONNECTION (PER CODE: CEC 705.12(B)(3)(2) [ NOT REQUIRED IF PANEL BOARD IS RATED NOT LESS THAN SUM OF AMPERE RATINGS OF ALL OVERCURRENT DEVICES SUPPLYING IT] WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVER-CURRENT DEVICE WARNING:PHOTOVOLTAIC POWER SOURCE LABEL LOCATION CONDUIT, COMBINER BOX [PER CODE: CEC 690.31(D)(2)] WARNING-Electric Shock Hazard No User Serviceable Parts inside Contact authorized service provide for assistance LABEL LOCATION INVERTER, JUNCTION BOXES(ROOF), AC DISCONNECT [PER CODE: CEC 690.13] LABEL LOCATION DISCONNECT, POINT OF INTERCONNECTION [PER CODE: CEC 690.13(B)] LABEL LOCATION AC DISCONNECT , POINT OF INTERCONNECTION [PER CODE: CEC 690.54] LABEL LOCATION MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLES AT LEAST EVERY 10 FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUNCTION BOXES. (PER CODE: CFC605.11.1.4) LABEL LOCATION POINT OF INTERCONNECTION [PER CODE: CEC705.12(D)(4)] ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: CEC 690.13(B)] DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION AC DISCONNECT,POINT OF INTERCONNECTION [PER CODE: CEC 690.13(B)] LABEL LOCATION WEATHER RESISTANT MATERIAL, DURABLE ADHESDIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN THE MAIN SERVICE DISCONNECT,PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERATED WITH THE SERVICE PANEL CLOSED. (PWER CODE: CEC690.15 ,690.13(B)) WARNING TRI POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM THIRD POWER SOURCE IS BATTERY STORAGE SYSTEM SOLAR DISCONNECT RATED AC OPERATING CURRENT AC NOMINAL OPERATING VOLTAGE 100.67 240 AMPS AC VAC PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.56(C)(1) LABEL LOCATION INVERTER,POINT OF INTERCONNECTION [PER CODE: CEC 690.56(C)(3)] RAPID SHUTDOWN SWITCH FOR SOLAR SYSTEM 2050 W MARTHA LN, SANTA ANA, CA 92706. MULTIPLE SOURCES OF POWER CAUTION:! CAUTION SOLAR PV SYSTEM AND BATTERY BACK-UP INSTALLED. WHEN POWER DISCONNECT, SOLAR PANELS AND BATTERY POWER WIRING MAY REMAIN ENERGIZED LABEL LOCATION POINT OF INTERCONNECTION(READILY ACCESSIBLE SWITCH WITHIN 10' OF THE MAIN SERVICE PANEL) (E) MAIN SERVICE PANEL (EXTERIOR) (E) PV INVERTER (EXTERIOR) (N) ENPHASE IQ COMBINER 5C (EXTERIOR) (N) ENPHASE IQ SYSTEM CONTROLLER 3G (EXTERIOR) (N) ESS-2 (EXTERIOR) (N) ESS-1 (EXTERIOR) NOT RS COMPLIANT (N) AC DISCONNECT (EXTERIOR) (N) ESS-4 (EXTERIOR) (N) ESS-3 (EXTERIOR) (N) ESS DISCONNECT (EXTERIOR) (E) AC DISCONNECT (EXTERIOR) LABEL LOCATION BATTERY DISCONNECT ESS DISCONNECT TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN CONDUCTORS OUTSIDE THE ARRAY. CONDUCTORS WITHIN THE ARRAY REMAIN ENERGIZED IN SUNLIGHT SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN ! EXISTING LABEL LOCATION AC DISCONNECT, DC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC690.56(C)(1) B B THE MAXIMUM CURRENT BACKFED BY THIS SYSTEM TO THE MAIN PANEL MAY BE CONTROLLED ELECTRONICALLY. REFER TO THE MANUFACTURER'S INSTRUCTIONS FOR MORE INFORMATION. PCS CONTROLLED CURRENT SETTINGS: 125AMPS LABEL LOCATION ENPHASE IQ SYSTEM CONTROLLER 3G 2050 W Martha Ln 9/16/2024 E-1.3 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:7/31/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. BACKUP LOAD PANEL SCHEDULE B BACKUP LOAD PANEL SCHEDULE 100A GARAGE SUB PANEL 100A 50 A 10 0 A ADU PANEL FRIDGE BEDROOOM ADU PANEL 50 A 20 A 20 A 10 0 A GARAGE SUB PANEL 20 A 2050 W Martha Ln 9/16/2024 E-1.4 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:9/6/2024 REV:C CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. MAIN SERVICE PANEL SCHEDULE MAIN SERVICE PANEL SCHEDULE MICRO AC AC KIT LIGHTS GFI KIT,GFI PLUGS WASHER DRYER POOL SMOKE DECT SPRINKLERS CONV KIT AND DINING ITS GARBAGE DISPOSAL SWITCHES LIVING ROOM ,BK PLUGS COMPUTER OUTLET, DOOR PLUG STOVE OVEN MASTRE ITS SOLAR SOLAR POOL SURGE PROTECTOR STOVE OVEN 20 0 A 30 A 3 0 A 20 A 20 A 20 A 2 0 A 20 A 50 A 5 0 A 20 A 15 A 20 A 20 A 20 A 20 A 20 A 20 A 20 A 30 A 30 A 20 A 20 A 15 A SERVICE DISCONNECT HO M HO M 2 5 0 P S P D 10 0 A 1 0 0 A IQ CONTROLLER 3G IQ CONTROLLER 3G 2050 W Martha Ln 9/16/2024 STREET (N) ENPHASE IQ SYSTEM CONTROLLER 3G (N) BACKUP LOAD PANEL (E) 225A MAIN SERVICE PANEL UT I L I T Y GR I D M (E) AC DISCONNECT (N) AC DISCONNECT BACKYARD EXTERIOR CONDUIT LENGTH APPROX.2' E-1.5 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:9/6/2024 REV:C CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. EQUIPMENT ELEVATION VIEW C EQUIPMENT ELEVATION VIEW SCALE:NTS APPROX.1'APPROX.1' 2050 W Martha Ln 9/16/2024 support@rvrengineering.com SEPTEMBER 06, 2024 Attn: RNRR CA- CA-City Of SANTA ANA RE: Project Name: Haverstick, Chiaki Project Address: 2050 W Martha Ln, Santa Ana, CA 92706. To whom it may concern: Thank you for reviewing and providing feedback on this project. The following is our response to the comments provided by the plan review, the numbers below correspond with the comment numbers provided in the city comment list: COMMENTS: 1.Comment: There can only be ONE power source attached to the main bus per the 120% rule CEC 705.12(B)(3)(2). Combine the backfeed sources together in a separate panel with their own OCPD breakers. Response: We've revised the mentioned connection, combined the existing and new solar using a load center, and fed them to the enphase controller. Refer to E-1.0 for details. 2.Comment: What are the conductors and the conduit schedule for these relocated loads? Be sure to account for ampacity reduction due to number of current carrying conductors (CEC 310.15(C) (1) and allow for required AFCI breakers if the length of the conduit exceeds 6 feet. CEC 210.12(D). Response We've shown the size of conductors and conduits used for the critical load panel on E-1.1 and the distance between the IQ system controller,MSP and the critical load panel will be approximately 1 feet which is less than 6 feet. Distance and conduit length are mentioned in the line diagram & Equipment elevation view on pages E-1.0 & E-1.5. 3.Comment: The existing PV back feed must be integrated with the new PV system. It cannot be located on the main panel along with the 100A IQ backfeed breaker (which is to be current limited to 70 total backfeed). Response: We've shown the correct PV backfeed value in the SLD. Refer to E-1.0 If you have any further questions, please don’t hesitate to contact our office. RAMASAMY R Design Engineer 2050 W Martha Ln 9/16/2024 CA Lic #657221 B C10, C-39 PO Box 8071 Redlands CA 92375 10 E Vine St #210 Redlands CA 92373 Office: 909-798-7457 Date: May 17, 2024 To: Chiaki Haverstick 2050 W Martha Ln Santa Ana, CA 92706 714-679-4863 jon@jonhaverstickstudio.com Fr: RNR Roofing Inc. PO Box 8071 Redlands CA 92375 CSLB 657221 909-253-6619 jackie@rnrroof.com Re: Residential Solar-Greater than 10kW w/ battery back-up Hello Mr. Haverstick, The City of Santa Ana requires Homeowners Authorization to install solar at your property listed above. Please sign below indicating RNR Roofing Inc. CSL No. 657221 is authorized to install solar as per the scope of work detailed in your contract at 2050 W Martha Lane Santa Ana, CA 92706. ___________________________________ ___________________________ Signature Date DocuSign Envelope ID: 9EC9F653-EAF5-4D52-8676-7ECFE64EF0D8 5/17/2024 2050 W Martha Ln 9/16/2024 CA Lic #657221 B C10, C-39 PO Box 8071 Redlands CA 92375 10 E Vine St #210 Redlands CA 92373 Office: 909-798-7457 BUILDING PERMIT LETTER OF AUTHORIZATION I, Gregg Miller, President do hereby grant permission to Jackie McKenna, Operations Manager to act as my agent in all aspects in order to obtain a building permit. This letter allows my agent to answer any and all questions on my behalf and to sign or pick up any and all documents on behalf of RNR Roofing Inc CA Lic #657221, however, I accept full responsibility to ensure that my project meets all zoning and building code compliance. ___________________________________ ___________________________ Signature Date ___________________________________ Title DocuSign Envelope ID: 1A2D645D-4882-44F1-AA5E-BB7CEB5BFA44 President 5/17/2024 2050 W Martha Ln 9/16/2024 5/17/2024 RE: Structural Certification for Installation of Residential Solar HAVERSTICK, CHIAKI: 2050 W MARTHA LN, SANTA ANA, CA 92706. Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 95 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E.Signed: 5/17/2024 EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 Attn: To Whom It May Concern This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition shingle roofing over roof plywood supported by 2X4 Rafters at 24 inches and 2X12 Rafters at 16 inches. The slope of the roof was approximated to be 18 and 22 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. Design Criteria projects@evengineersnet.com http://www.evengineersnet.com 2050 W Martha Ln 9/16/2024 Structural Letter for PV Installation Date: 05/17/2024 Job Address: 2050 W MARTHA LN SANTA ANA, CA 92706. Job Name: HAVERSTICK, CHIAKI Job Number: 240117HC Sheet 2 Cover 3 Attachment Uplift checks 4 Roof Framing Check 5 Seismic Check and Scope of work Code 2022 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 95 mph Exposure C NDS for Wood Construction Sincerely, Signed: 5/17/2024 Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. projects@evengineersnet.com http://www.evengineersnet.com 2050 W Martha Ln 9/16/2024 Wind Load Cont. 95 mph ASCE 7-16 Figure 26.5-1B C 1.0 ASCE 7-16 Sec 26.8.2 0.85 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 1.00 ASCE 7-16 Table 26.9-1 16.64 psf 18.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1,2e)Zone(2r, 2n)Zone(3e)Zone(3r) Fig. 30-3-2 GCp=-1.1 -2 -2 -2.4 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-21.96 -39.93 -39.93 -47.91 GCp=0.5 Figure 30.3-2 P=qh(GCp)(γE)(γa)=5.49 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing=6 ft 5/16" Lag Screw Withdrawal Value=266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity=760 lbs Zone Trib Width Area (ft)Uplift (lbs)Down (lbs) Zone(1,2e)6 16.5 135.9 140.1 Zone(2r, 2n)6 16.5 233.7 140.1 Zone(3e)6 16.5 233.7 140.1 Zone(3r)6 16.5 277.2 140.1 Conservative Max=277.2 <760 CONNECTION IS OK Risk Category = KZ = Kd = Ke = 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration projects@evengineersnet.com http://www.evengineersnet.com 2050 W Martha Ln 9/16/2024 Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg=0 psf Ct =1.1 Ce =0.9 Is =1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1)0 plf Max Length, L =8.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT =24 in Dr =10 psf 20 plf PvDL =3 psf 18 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL=43 plf Mdown=344 lb-ft Mallowable = Sx x Fb' (wind)=456 lb-ft >344 lb-ft OK Load Case: DL+S Ps+ Ppvcos(θ)+PDL=38 plf Mdown=304 lb-ft Mallowable = Sx x Fb' (wind)=456 lb-ft >304 lb-ft OK Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL=44.6 plf Max Moment, Mu=357 lb-ft Mallowable = Sx x Fb' (wind)=634 lb-ft >357 lb-ft OK Pv max Shear=140.1 lbs Shear, Vu=wL/2+Pv Point Load =292 lbs Max Shear, Vu=wL/2+Pv Point Load =292 lb Member Capacity DF-L No.2 2X4 CL CF Ci Cr KF φ λ Fb =900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E =1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d =3.5 in Width, b =1.5 in Cross-Sectonal Area, A =5.25 in2 Moment of Inertia, Ixx =5.35938 in4 Section Modulus, Sxx =3.0625 in3 Allowable Moment, Mall = Fb'Sxx =396.2 lb-ft DCR=Mu/Mall =0.75 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.46 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 2050 W Martha Ln 9/16/2024 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 36% Dpv and Racking 3 psf Average Total Dead Load 11.1 psf Increase in Dead Load 4.3%OK The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Limits of Scope of Work and Liability We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - HAVERSTICK, CHIAKI. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this Structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. 2050 W Martha Ln 9/16/2024 support@rvrengineering.com SEPTEMBER 06, 2024 Attn: RNRR CA- CA-City Of SANTA ANA RE: Project Name: Haverstick, Chiaki Project Address: 2050 W Martha Ln, Santa Ana, CA 92706. To whom it may concern: Thank you for reviewing and providing feedback on this project. The following is our response to the comments provided by the plan review, the numbers below correspond with the comment numbers provided in the city comment list: COMMENTS: 1.Comment: There can only be ONE power source attached to the main bus per the 120% rule CEC 705.12(B)(3)(2). Combine the backfeed sources together in a separate panel with their own OCPD breakers. Response: We've revised the mentioned connection, combined the existing and new solar using a load center, and fed them to the enphase controller. Refer to E-1.0 for details. 2.Comment: What are the conductors and the conduit schedule for these relocated loads? Be sure to account for ampacity reduction due to number of current carrying conductors (CEC 310.15(C) (1) and allow for required AFCI breakers if the length of the conduit exceeds 6 feet. CEC 210.12(D). Response We've shown the size of conductors and conduits used for the critical load panel on E-1.1 and the distance between the IQ system controller,MSP and the critical load panel will be approximately 1 feet which is less than 6 feet. Distance and conduit length are mentioned in the line diagram & Equipment elevation view on pages E-1.0 & E-1.5. 3.Comment: The existing PV back feed must be integrated with the new PV system. It cannot be located on the main panel along with the 100A IQ backfeed breaker (which is to be current limited to 70 total backfeed). Response: We've shown the correct PV backfeed value in the SLD. Refer to E-1.0 If you have any further questions, please don’t hesitate to contact our office. RAMASAMY R Design Engineer 2050 W Martha Ln 9/16/2024 support@rvrengineering.com JUNE 29, 2024 Attn: RNRR CA- CA-City Of SANTA ANA RE: Project Name: Haverstick, Chiaki Project Address: 2050 W Martha Ln, Santa Ana, CA 92706. To whom it may concern: Thank you for reviewing and providing feedback on this project. The following is our response to the comments provided by the plan review, the numbers below correspond with the comment numbers provided in the city comment list: COMMENTS: 1.Comment: Is this 125A subpanel supplying the ADU? Show Details. Response: Yes!, the 125A sub-panel is supplying the ADU. 2.Comment: There is already a service meter upgrade permit in play. Permit #20182612 Issued 4/24/24. There cannot be another Service meter as a part of this project as proposed. You must reflect the current service equipment being installed as a part of this design. Response: We revised the MSP to the existing one. Refer to its m leaders on PV-1.0 and in line diagram E-1.0. 3.Comment: There can only be ONE power source attached to the main bus per the 120% rule CEC 705.12(B)(3)(2). Combine the backfeed sources together in a separate panel with their own OCPD breakers. Response: We've removed the mentioned connection, combined the existing and new solar using a load center, and fed them to the enphase controller. Refer to E-1.0 for details. 4.Comment: This is incorrect. You must also include the ESS backup power sources. The total available backfeed current for the proposed project is 92.94A. The PV system provides 40.84A and the 2 ESS units total [(5000 / 240) x (2) x (1.25)] = 52.1A. The existing 20A PV backfeed is added to create a total backfeed on the 225A bus of 112.94A. Redesign the system to keep the total backfeed current at 70A or less for code compliance. Response: We've removed the m leader and added a note for the PCS-controlled current setting with value. Refer to E-1.0 for details. Note: Plans reflect a change in equipment from Tesla to Enphase Batteries and Gateway. The responses below correlate with the city corrections requested and the new version plans where applicable. 2050 W Martha Ln 9/16/2024 5. Comment: What loads are being relocated here? Provide detailed panel schedules for the Main Panel and the Critical Load panel--include ACCURATE ckt descriptions and loads. Response: We've included the panel schedules for the main panel and the critical load panel. Refer to E-1.2 & E-1.3 for details. 6. Comment: What are the conductors and the conduit schedule for these relocated loads? Be sure to account for ampacity reduction due to number of current carrying conductors (CEC 310.15(C)(1)) and allow for required AFCI breakers if the length of the conduit exceeds 6 feet. CEC 210.12(D). Response: We've shown the size of conductors and conduits used for the critical load panel on E-1.1 and the distance between the IQ system controller and the critical load panel will be approximately 2 feet which is less than 6 feet. Distance is mentioned in the line diagram on page E-1.0. 7. Comment: Specify the building that each of these arrays is sitting upon. Response: We've specified the location of the arrays on which building they mounted on E-1.0. 8. Comment: Each PV array MUST be grounded to the GEC system located at the building upon which the array sits. If there is no GEC system, one MUST be added. Clearly show and specify the GEC system for EACH building, and how the PV arrays are to be bonded to these building GEC systems. Response: We've shown new the GEC system for the ADU and the garage building since the main house has the existing GEC. Refer to PV-1.0 and E-1.0 for details. 9. Comment: There is almost nothing right about this placard! This placard is for Emergency Responders—to QUICKLY identify how to shut off power to the buildings. It is NOT a store directory. Re-Work the placard as follows (See CEC 705.10): a) The entire “warning” statement is wrong. It should read “CAUTION: MULTIPLE SOURCES OF POWER”. b) Eliminate ALL wording that is NOT for a disconnect or ESS source. 1) Show the batteries as ESS period. 2) Show the Main panel, AC disconnect, PV Inverter, Load Center (which has the ESS disconnects). c) The existing PV system is NOT rapid shutdown compliant. Place a DOTTED line around the existing PV panels to identify them as not-RS compliant. See CEC 690.56(C)(1) Response: We've revised the placards under the above instructions on E-1.4. If you have any further questions, please don’t hesitate to contact our office. RAMASAMY R Design Engineer 2050 W Martha Ln 9/16/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 2050 W Martha Ln, Santa Ana, CA 92706, USA RNR Roofing and Solar 657221 Gregg Miller 909-292-7114 jenny@rnrsolar.com 1/17/2024 2050 W Martha Ln 9/16/2024 PD-1.0 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. MODULE SPECSHEET 2050 W Martha Ln 9/16/2024 PD-1.1 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. INVERTER SPECSHEET 2050 W Martha Ln 9/16/2024 PD-1.2 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. COMBINER SPEC SHEET 2050 W Martha Ln 9/16/2024 PD-1.3 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. RACKING SPECSHEET 2050 W Martha Ln 9/16/2024 PD-1.4 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. MOUNT SPECSHEET 2050 W Martha Ln 9/16/2024 PD-1.5 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. GROUNDING SPECSHEET 2050 W Martha Ln 9/16/2024 PD-1.6 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. INTEGRATED GROUNDING SPECSHEET 2050 W Martha Ln 9/16/2024 PD-1.7 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. FIRE RATING CERTIFICATE 2050 W Martha Ln 9/16/2024 PD-1.8 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. ENPHASE IQ SYSTEM CONTROLLER 3G SPECSHEET 2050 W Martha Ln 9/16/2024 PD-1.9 CUSTOMER INFORMATION NAME&ADDRESS: 33°45'23.26"N 117°53'56.29"W APN:004-161-28 AHJ:CA-CITY OF SANTA ANA SYSTEM INFORMATION DESIGNER/CHECKED BY: GV/PI PROJECT NUMBER:RNRR-010696 SCALE:AS NOTED PAPER SIZE:17"x11" HAVERSTICK, CHIAKI 2050 W MARTHA LN, SANTA ANA, CA 92706. ENGINEER OF RECORD DATE:6/29/2024 REV:B CONTRACTOR INFORMATION NEW SYSTEM: DC SYSTEM SIZE: 10665W AC SYSTEM SIZE: 7830W CEC AC SYSTEM SIZE: 9762W MODULES: (27)CANADIAN SOLAR CS3N-395MS INVERTER: (27)ENPHASE IQ8PLUS-72-2-US(240V,1PH) BRANCH DETAILS: 1 BRANCH OF 13 MICRO INVERTERS (13 MODULES) 1 BRANCH OF 11 MICRO INVERTERS (11 MODULES) 1 BRANCH OF 3 MICRO INVERTERS (3 MODULES) BATTERY: (4) ENPHASE IQ BATTERY 5P-1P-NA,5kWH BATTERY WITH 6 INTERGRATED IQ8D-BATTERY MICRO-INVERTERS 10E. VINE ST, SUITE 216, REDLANDS, CA 92373. TEL:(909) 798-7457 LIC:#B,C39@657221. BATTERY SPECSHEET 2050 W Martha Ln 9/16/2024 Certificate Of Completion Envelope Id: 1A2D645D488244F1AA5EBB7CEB5BFA44 Status: Completed Subject: Complete with DocuSign: Letter of Authorization McKenna J.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 4 Initials: 0 RNR ROOFING INC Jackie McKenna AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) PO Box 8071 Redlands, CA 92375 jackie@rnrroof.com IP Address: 47.153.112.152 Record Tracking Status: Original 5/17/2024 5:43:16 PM Holder: RNR ROOFING INC Jackie McKenna jackie@rnrroof.com Location: DocuSign Signer Events Signature Timestamp Gregg Miller gregg@rnrroof.com President RNR Roofing, Inc. Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 174.205.127.167 Signed using mobile Sent: 5/17/2024 5:44:42 PM Viewed: 5/17/2024 5:45:02 PM Signed: 5/17/2024 5:45:08 PM Electronic Record and Signature Disclosure: Accepted: 10/24/2019 4:33:15 PM ID: 704a25c7-822a-42ce-ab58-fc1af153bd16 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 5/17/2024 5:44:42 PM Certified Delivered Security Checked 5/17/2024 5:45:02 PM Signing Complete Security Checked 5/17/2024 5:45:08 PM Completed Security Checked 5/17/2024 5:45:08 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure 2050 W Martha Ln 9/16/2024 ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, RNR Roofing, Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to these terms and conditions, please confirm your agreement by clicking the ‘I agree’ button at the bottom of this document. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures Electronic Record and Signature Disclosure created on: 6/9/2014 2:10:52 PM Parties agreed to: Gregg Miller 2050 W Martha Ln 9/16/2024 electronically from us. How to contact RNR Roofing, Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: jackie@rnrroof.com To advise RNR Roofing, Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at jackie@rnrroof.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address.. In addition, you must notify DocuSign, Inc. to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from RNR Roofing, Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an e-mail to jackie@rnrroof.com and in the body of such request you must state your e-mail address, full name, US Postal address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with RNR Roofing, Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an e-mail to jackie@rnrroof.com and in the body of such request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to 2050 W Martha Ln 9/16/2024 other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that: • I can access and read this Electronic CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC RECORD AND SIGNATURE DISCLOSURES document; and • I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and • Until or unless I notify RNR Roofing, Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by RNR Roofing, Inc. during the course of my relationship with you. 2050 W Martha Ln 9/16/2024 Certificate Of Completion Envelope Id: 9EC9F653EAF54D5286767ECFE64EF0D8 Status: Completed Subject: Complete with DocuSign: Letter of Authorization Homeowner.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 4 Initials: 0 RNR ROOFING INC Jackie McKenna AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) PO Box 8071 Redlands, CA 92375 jackie@rnrroof.com IP Address: 47.153.112.152 Record Tracking Status: Original 5/17/2024 5:33:38 PM Holder: RNR ROOFING INC Jackie McKenna jackie@rnrroof.com Location: DocuSign Signer Events Signature Timestamp Chiaki Haverstick jon@jonhaverstickstudio.com Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 108.228.224.62 Sent: 5/17/2024 5:37:16 PM Viewed: 5/17/2024 6:05:37 PM Signed: 5/17/2024 6:05:57 PM Electronic Record and Signature Disclosure: Accepted: 5/17/2024 6:05:37 PM ID: d54b615d-829e-4f5c-8aa5-cfb1039be755 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 5/17/2024 5:37:16 PM Certified Delivered Security Checked 5/17/2024 6:05:37 PM Signing Complete Security Checked 5/17/2024 6:05:57 PM Completed Security Checked 5/17/2024 6:05:57 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure 2050 W Martha Ln 9/16/2024 ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, RNR Roofing, Inc. (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to these terms and conditions, please confirm your agreement by clicking the ‘I agree’ button at the bottom of this document. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures Electronic Record and Signature Disclosure created on: 6/9/2014 2:10:52 PM Parties agreed to: Chiaki Haverstick 2050 W Martha Ln 9/16/2024 electronically from us. How to contact RNR Roofing, Inc.: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: jackie@rnrroof.com To advise RNR Roofing, Inc. of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at jackie@rnrroof.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address.. In addition, you must notify DocuSign, Inc. to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from RNR Roofing, Inc. To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an e-mail to jackie@rnrroof.com and in the body of such request you must state your e-mail address, full name, US Postal address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with RNR Roofing, Inc. To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an e-mail to jackie@rnrroof.com and in the body of such request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems: Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Browsers: Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader: Acrobat® or similar software may be required to view and print PDF files Screen Resolution: 800 x 600 minimum Enabled Security Settings: Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Acknowledging your access and consent to receive materials electronically To confirm to us that you can access this information electronically, which will be similar to 2050 W Martha Ln 9/16/2024 other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that: • I can access and read this Electronic CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC RECORD AND SIGNATURE DISCLOSURES document; and • I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and • Until or unless I notify RNR Roofing, Inc. as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by RNR Roofing, Inc. during the course of my relationship with you. 2050 W Martha Ln 9/16/2024