HomeMy WebLinkAbout2112 S Woodland Pl - Plan1099198 CONTRACTOR LICENSE NUMBER AERIAL VIEW GENERAL NOTES PROJECT NOTES: THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE LOCAL ELECTRIC CODE ( ) ARTICLE 690, ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTIONS (AHJ) APPLICABLE CODES. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICRO INVERTER IN ACCORDANCE WITH 690.41(B). ALL PV SYSTEM COMPONENTS, MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY 690.4: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE. INVERTERS UL1741 CERTIFIED, IEEE 1547, 929, 519. COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO 690.7. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 ((D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING 110.3. ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE AND AHJ. WORK INCLUDED: PV ROOF ATTACHMENTS PV RACKING SYSTEM INSTALL ATION - EVEREST CROSSRAIL 44-X PV MODULE AND INVERTER INSTALLATION PV EQUIPMENT GROUNDING. PV SYSTEM WIREING TO A ROOF-MOUNTED JUNCTION BOX. PV LOAD CENTERS (IF INCLUDED). PV METERING/MONITORING (IF INCLUDED). PV DISCONNECTS. PV FINAL COMMISSIONING. (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. PLANSET-1 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 04/25/2023 EE 3 COVER SHEET PS-1 TABLE OF CONTENTS: PS-1 - COVER SHEET PS-2 - SITE NOTES PS-3 - SITE PLAN PS-4 -FIRE ACCESS PS-5 - MODULE AREA PS-6 - RACKING DETAIL PS-7 - ELECTRICAL LINE PS-8 - PLACARDS FM-1 FIELD MARKINGS RS-1 - RS-6 - RESOURCE DOCUMENT SCOPE OF WORK: INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SYSTEM 3.7kW AC PHOTOVOLTAIC SOLAR ARRAY PV MODULES: (Aptos 370 watt) DNA-120-MF26-370W INVERTER(S): Enphase IQ7PLUS-72-2-US ROOF TYPE: Composition Shingle PV MOUNTING HARDWARE: QUICK BOLT (QB2) 17662 (COMP SHINGLE) AHJ:SANTA ANA CITY BUILDING CODE:2022 CBC ELECTRICAL CODE:2022 CEC FIRE CODE:2022 CBC RESIDENTIAL CODE:2022 CRC CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 CEC CEC CEC CEC CEC CEC MODULE QUANTITY: 10 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101115397 Elec# 20179849 Issued 06/08/23 2112 S Woodland Pl 06/20/23 SITE NOTES: A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATION. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WHIT NO STORAGE BATTERIES. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION CEC 110.26 ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND APPROVED MANUFACTURERS INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. EQUIPMENT LOCATIONS: ALL EQUIPMENT SHALL MEET MINIMUM SETBAKC AS REQUIRED BY CEC 110.26. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMERATURES AS SPECIFIED BY CEC 690.31 (A),(C) AND CEC TABLES 310.15 (B)(2)(C). JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC 690.34 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO CEC APPLICABLE CODES. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. STRUCTURAL NOTES: RACKING SYSTEM AND PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST BE ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURERS INSTRUCTIONS. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED AND SEALED PER LOCAL REQUIREMENTS. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. EQUIPMENT LOCATIONS: ALL EQUIPMENT SHALL MEET MINIMUM SETBAKC AS REQUIRED BY CEC 110.26. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMERATURES AS SPECIFIED BY CEC 690.31 (A),(C) AND CEC TABLES 310.15 (B)(2)(C). JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO CEC 690.34 ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO CEC APPLICABLE CODES. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. WIRING AND CONDUIT NOTES: ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. CONDUCTOR SIZED ACCORDING TO CEC 690.8, CEC 690.7. VOLTAGE DROP LIMITED TO 1.5% DC WIREING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIREING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIREING CLIPS. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PAHSE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOR, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GRAY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [CEC 110.15]. grounding notes: grounding system components shall be listed for their purpose, and grounding devices exposed to the elements shall be rated for such use. pv equipment shall be grounded according to cec 690.43 and minimum cec table 250.122 mental parts of modules frames, modules racking, and enclosures considered groined in accord with 250.134 and 250.136(a). equipment grounding conductors shall be sized according to cec 690.45 and micoinverters manufacturers instructions. each modules will be grounded using weeb grounding clips as shown in manufacturer documentation and approved by the ahj. if weebs are not used, module grounding lugs must be installed at the specified grounding lugs holes per the manufacturers installation requirements. the grounding connection to a module shall be arranged such that the removal of a module does not interrupt a grounding conductor to another module. grounding and bonding conductors, if insulated, shall be colored green or marked green if #4 awg or larger [cec 250.119]. the grounding electrode system complies with cec 690.47 and cec 250.50 through 250.106. if existing system is inaccessible, or inadequate, a grounding electrode system provided according to cec 250, cec 690.47 and ahj. grounding-fault detection shall comply with cec 690.41(b)(1) and (2) to reduce fire hazards. disconnection and over-current protection notes: disconnecting switches shall be wired such that when the switch is opened the conductors remaining energized are connected to the terminals marked "lineside" (typically the upper terminals). disconnects to be accessible to qualified utility personnel, be lockable, and be a visible-break switch. pv system circuits installed on or in buildings shall include a rapid shutdown function to reduce shock hazard for emergency responders in accordance with 690.12(a) through (d). all ocpd ratings and types specified according to cec 690.8, 690.9, and 240. microinverter branches connected to a single breaker or grouped fuses in accordance with cec 110.3(b). if required by ahj, system will included arc-fault circuit protection according to cec 690.11 and ul 1699b. interconnection notes: load-side interconnection shall be in accordance with [cec 705.12(b)] the sum of the utility ocpd and inverter continuous output may not exceed 120% of busbar rating [cec 705.12(d)(2)(3)]. the sum of 125 percent of the power source(s) output circuit current and the rating of the over current device protecting the busbar shall not exceed 120 percent of the ampacity of the busbar, pv dedicated back feed breakers must be located opposite end of the bus from the utility source ocpd [cec 705.12(b)(2)(3)]. at multiple electric power sources output combiner panel, total rating of all over current devices shall not exceed ampacity of busbar, however, the combined over current device may be excluded according to cec 705.12(b)(2)(3)(c). feeder tap interconnection (load side) according to cec 705.12 (b)(2)(1). supply side tap interconnection according to cec 705.12 (a) with service entrance conductors in accordance with cec 230.42 backfeeding breaker for electric power sources output is exempt from additional fastening [cec 705.12(b)(5). PLANSET-2 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: site notes PS-2 CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC CEC AHJ:SANTA ANA CITY BUILDING CODE:2022 CBC ELECTRICAL CODE:2022 CEC FIRE CODE:2022 CBC RESIDENTIAL CODE:2022 CRC ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 2112 S Woodland Pl06/20/23 RS1 RS2 FR O N T O F H O M E 22 1 2 S O U T H W O O D L A N D P L A C E PLANSET-3 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: sKte RNan PS-3 AHJ:SANTA ANA CITY BUILDING CODE:2022 CBC ELECTRICAL CODE:2022 CEC FIRE CODE:2022 CBC RESIDENTIAL CODE:2022 CRC ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 32'-5" 6'-1" 11'-7" 57'-0" EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 Apr 25 2023 2112 S Woodland Pl06/20/23 RS1 RS2 FR O N T O F H O M E 22 1 2 S O U T H W O O D L A N D P L A C E (E) MAIN SERVICE PANEL (E) UTILITY METER / MAIN SERVICE PANEL (E) SUBPANEL (N) PV LOAD CENTER (N) PV PRODUCTION METER FIRE SETBACK (N) AC DISCONNECT (VISIBLE LOCKABLE LABELED DISCONNECT) (N) PV MODULE SYSTEM LEGEND (N) PV COMBINER PANEL (N) JUNCTION BOX (N) DC-DC / STRING INVERTER (N) MICROINVERTER (N) DC DISCONNECT ROOF SECTION CRITERIA AND SPECIFICATIONS PLANSET-4 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: (IRE ACCESS AND ROO( IN(ORMATION PS-4 all modules will be installed in compliance with fire code.2019 CBC AHJ:SANTA ANA CITY BUILDING CODE:2022 CBC ELECTRICAL CODE:2022 CEC FIRE CODE:2022 CBC RESIDENTIAL CODE:2022 CRC ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 ROOF SECTION QUANTITY KILOWATTAGE ROOF PITCH AZIMUTH TSRF RS1 4 1.48kW 20° 98 98% RS2 6 2.22kW 20° 88 88% RS3 0kW RS4 0kW RS5 0kW 3'-0" 3'-0" 3'-0" 3'-0" 1'-6" 1'-6" 3'-0" 1'-6" 1'-6" EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 Apr 25 2023 2112 S Woodland Pl06/20/23 RS1 RS2 FR O N T O F H O M E 22 1 2 S O U T H W O O D L A N D P L A C E (E) MAIN SERVICE PANEL (E) UTILITY METER / MAIN SERVICE PANEL (E) SUBPANEL (N) PV LOAD CENTER (N) PV PRODUCTION METER FIRE SETBACK (N) AC DISCONNECT (VISIBLE LOCKABLE LABELED DISCONNECT) (N) PV MODULE SYSTEM LEGEND (N) PV COMBINER PANEL (N) JUNCTION BOX (N) DC-DC / STRING INVERTER (N) MICROINVERTER (N) DC DISCONNECT PLANSET-5 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: MODULE AREA AND RAFTER INFORMATION PS-5 ROOF MEMBERS AHJ:SANTA ANA CITY BUILDING CODE:2022 CBC ELECTRICAL CODE:2022 CEC FIRE CODE:2022 CBC RESIDENTIAL CODE:2022 CRC FRAMING TYPE: Manufactured Wood Truss RAFTER SIZE: 2x4 RAFTER SPACING: 24 RAFTER SPAN: 72 ROOF TYPE:Composition Shingle SHEATHING TYPE: 7/16" OSB STRUCTURE TYPE:Inhabited - Gable Roof WIND EXPOSURE CATEGORY: B NUMBER OF PV ARRAYS: 2 TOTAL ROOF AREA (SQ. FT): 1600 ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 Apr 25 2023 2112 S Woodland Pl06/20/23 PLANSET-6 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: RAC-IN) AN& ASSEMBL; &ETAIL PS-6 structural information: HOME IS FRAMED WITH 2X4 TRUSSES AT 24" ON CENTER. construction notes: 1. solar photovoltaic system to be installed on residential structure. 2. this project has been designed in compliance with section 1609 to withstand a basic wind speed of 110 mph (3 second gust), 3. connection to structure shall not be within 6" of nailing plates. 4. the solar PV installation shall not obstruct any plumbing, mechanical or building roof vents. 5. all conductors and conduits mounted on roof shall be minimum 3 3 4" above roof surface (including cables underneath modules and racking). 6. roof access points shall be provided per the following ( r324.6, cvc 3111.2.1): located in areas not requiring placement of ground ladders over openings such as doors or windows. located at strong points of building construction in locations where access point does not conflict with overhead obstructions such as: tree limbs, wires or signs. AHJ:SANTA ANA CITY BUILDING CODE:2022 CBC ELECTRICAL CODE:2022 CEC FIRE CODE:2022 CBC RESIDENTIAL CODE:2022 CRC CEC CEC ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 3'-9" 5'-9" (Aptos 370 watt) DNA-120-MF26-370W *NOT TO SCALE*NOT TO SCALE *NOT TO SCALE LAG BOLT EMBEDMENT: 2.5" MINIMUM LAG BOLT DIAMETER: 5/16" 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 Mar 31 2023 2112 S Woodland Pl06/20/23 120/240 VAC 60HZ SINGLE PHASE UTILITY SERVICE LL L L N + - + - + + - - + + - - EGC L2 L1 EGC L2 L1 GN D N L2 L1 EGC AB C JUNCTION BOX (OPTIONAL - FOR CONDUCTOR SPLICE) JUNCTION BOX (OPTIONAL - FOR CONDUCTOR SPLICE) INTEGRATED 2P OCPD FOR IQ ENVOY GATEWAY, 15A MAX (1) CIRCUIT OF 10 MODULES (N)20A/2P ENPHASE IQ COMBINER 3 (PV CIRCUITS ONLY) VISIBLE LOCKABLE LABELED PV AC DISCONNECT 30A, 240V, 2P, NON- FUSED LOCKABLE, VISIBLE OPEN EGC N L2 L1 N N C (E)LOADS (E)LOADS SECONDARY POWER SOURCE (PV OCPD) TO BE LOCATED AT OPPOSITE END OF BUSBAR FROM PRIMARY SOURCE (MAIN OCPD) (NEC 705.12) GN D N EGC N L2 L1 GEC (E)GROUNDING ELECTRODE SYSTEM LOAD-SIDE SOURCE CONNECTION BUSBAR PLUG-IN TYPE BREAKER (NEC 705.12) C (E)100A/2P (N)20/2P (E)100A MAIN SERVICE PANEL (E)100A/2P MAIN DISCONNECT PLANSET-7 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: ELECTRICAL LINE DIAGRAM PS-7 MPU REQUIRED: NO TAG CONDUCTOR TYPE MINIMUM WIRE SIZE # OF CONDUCTORS RACEWAY/ CABLE TYPE MINIMUM CONDUIT SIZE A CABLE (USE-2)10 2 USE-2 / FREE AIR FREE AIRBARE COPPER (EGC)6 1 BARE / FREE AIR B CU THHN OR NM-B CABLE *10 2 EMT OR EQUIVALENT / NM-B CABLE OR UF-B / FLEX 3/4" INTERIOR USECU THHN OR NM-B CALBE (EGC)*10 1 C CU THHN/THWN-2 10 3 EMT OR EQUIVALENT 3/4"CU THHN/THWN-2 (EGC)10 1 AHJ:SANTA ANA CITY BUILDING CODE:2022 CBC ELECTRICAL CODE:2022 CEC FIRE CODE:2022 CBC RESIDENTIAL CODE:2022 CRC ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 2112 S Woodland Pl06/20/23 RS1 RS2 FR O N T O F H O M E 22 1 2 S O U T H W O O D L A N D P L A C E ALL CAUTION, WARNING, OR DANGER SIGNS OR LABELS SHALL: 1, COMPLY WITH ANSI Z535.4-2011 STANDARDS. 2. BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING METHOD AND SHALL NOT BE HANDWRITTEN. 3. SHALL BE OF SUFFICEINT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. 4. UNLESS OTHERS SPECIFIED MINIMUM TEXT HEIGHT TO BE 1 8" (3MM). PLANSET-8 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: PLACAR&S PS-9 !caution! power to this building is also supplied from roof mounted solar arrays with safety disconnects as shown: main distribution utility disconnect pv array AHJ:SANTA ANA CITY BUILDING CODE:2022 CBC ELECTRICAL CODE:2022 CEC FIRE CODE:2022 CBC RESIDENTIAL CODE:2022 CRC ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE ELECTRICAL WARNING LABELS 240240 0 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 2112 S Woodland Pl06/20/23 FIELD MARKINGS SITE INFORMATION drawn by: sheet name: REVISION: sheet number: FIEL& MAR-IN)S FM-1ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 2112 S Woodland Pl06/20/23 RESOURCE -1 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: MO&ULE S2EC S*EET RS-1ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 2112 S Woodland Pl06/20/23 RESOURCE - 2 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: INVERTER S2EC S*EET RS-2ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 2112 S Woodland Pl06/20/23 RESOURCE - 3 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: COMBINER BO: S2EC S*EET RS-3ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 2112 S Woodland Pl06/20/23 RESOURCE - 4 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: RAILIN) S2EC S*EET RS-4ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 06/01/2023 2112 S Woodland Pl06/20/23 RESOURCE -5 SITE INFORMATION drawn by: sheet name: REVISION: sheet number: ANC*OR S2EC S*EET RS-5ELISABETH LE GUIN 2212 SOUTH WOODLAND PLACE SANTA ANA CALIFORNIA 92707 EE 1099198 CONTRACTOR LICENSE NUMBER CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLID STATE ELECTRIC LLC, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENT ORGANIZATIONS, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLID STATE ELECTRIC LLC. FLEX ENERGY ELECTRIC LLC 472 E 1750 N SUIT 200, VINEYARD, UT 84059 04/25/2023 3 06/01/2023 2112 S Woodland Pl06/20/23 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 2112 S Woodland Pl06/20/23 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 4 Comp shingle 4 Flashing 4 K2 CrossRail 44-X 563 20 21 6 475 5 2112 S Woodland Pl06/20/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan Elisabeth Le Guin 2112 S Woodland Pl, Santa Ana, CA 92707 3.7 kW Flex Energy Electric 330 E 1750 N BLDG B Vineyard, UT 84059 3.7 2112 S Woodland Pl06/20/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram 3.7 10 (Aptos 370 watt) DNA-120-MF26-370W Enphase IQ7PLUS-72-2-US 10 2 10 210 1 10 3 10 1 2112 S Woodland Pl06/20/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) 3.7 Aptos DNA 120 20 34.95 41.75 11.25 20 1000 1000 Enphase IQ7PLUS-72-2-US 64 64 2112 S Woodland Pl06/20/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M -19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 2112 S Woodland Pl, Santa Ana, CA 92707 Flex Energy Electric, LLC 1099198 Nathan Crellin 661-486-1810 3/20/2023 Nathaniel.crellin@flexenergysolar.com 4/4/2023 2112 S Woodland Pl06/20/23 STRUCTURAL CERTIFICATION REPORT Roof-mounted Solar Panels March 31, 2023 To: Flex Energy Solar Re: Elisabeth Le Guin 330 E 1750 N Building B 2112 S Woodland Pl Vineyard, UT 84058 Santa Ana, CA 92707 Flex Energy Solar proposes to install new roof-mounted solar panels at this residence and asked Right Angle Engineering to review the existing structure for suitability. This letter summarizes the methods that were used to survey, evaluate, and certify the existing roof framing and the attachment of the new solar panels to it. STRUCTURAL DESIGN Building Code: California Residential Code 2022 Design Standards: ASCE 7-16 Snow: Ground: pg= 0.0 psf | Flat Roof: pf= 0.0 psf | Sloped Roof: ps= 0.0 psf Wind: Ultimate Wind Speed = 95.0 mph | Exposure = C Seismic: Risk Category = 2 | Seismic Design Category = A | Site Class = D STRUCTURE Field Technicians from Flex Energy Solar visited the site and observed the existing structure : Array Name Panel Quantity Roof Framing Material Pitch Array 1 4 Pre-Manufactured Truss | 24" o.c.Asphalt Shingles 20° Array 2 6 Pre-Manufactured Truss | 24" o.c.Asphalt Shingles 20° ANCHORAGE The solar panel anchorage shall be installed according to the manufacturer's most current installation manual. Anchorage shall be staggered to distribute the load evenly to adjacent roof members. The solar panels should be mounted flush to the roof surface. Array Name Connection Type Fastener Max Anchorage Spacing Array 1 Quickbolt QB2 5/16” lag screw (2.5" embedment) into roof substructure 72" Array 2 Quickbolt QB2 5/16” lag screw (2.5" embedment) into roof substructure 72" Installation Instructions Solar panels and the equipment shall be installed per the manufacturer's installation specifications. Improper installation will void this certification. Deviations from the approved structural plans (including equipment substitutions) are not allowed without written approval from Right Angle Engineering. Prior to installation, the installer should: · Confirm that the existing structure matches the information provided in the structural survey, the approved installation plans and this certification. · Identify discrepancies between this certification and the approved installation plans. If found, then this certification shall govern. · Identify structural elements that are dangerous (cracked, broken, excessive sag, signs of overstress, rot,decay, fire, water). If found, installation shall cease until those elements are adequately abated and made to comply with the referenced building code. · Verify that both the existing structure and the solar addition has been permitted through the AHJ. 581 E Technology Ave, C1500 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 1 of 5 2112 S Woodland Pl06/20/23 STRUCTURAL CERTIFICATION I certify the addition of solar panels on the roof of this structure does not cause the structure to become unsafe or make it generally less compliant with the life-safety requirements of the referenced building code. Based on the evaluation methods described below, for the loads that exist at this site, the existing framing will safely support the new solar panels if they are installed and attached correctly. Electrical design is not included in this certification. Array Name Certification Method Retrofits Array 1 Prescriptive method California Existing Building code 502A.4 None required Array 2 Prescriptive method California Existing Building code 502A.4 None required Regards, 03/31/2023 Robert D. Smythe, P.E. Right Angle Engineering 581 E Technology Ave, C1500 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 2 of 5 2112 S Woodland Pl06/20/23 Job Details Roof Snow Load - ASCE 7-16 Design Criteria Ground Snow Load (pg) Section 7.2 0.0 psf Design Wind Speed 95.0mph Exposure Factor (Ce) Table 7.3-1 0.9 Exposure Category C Thermal Factor (C t) Table 7.3-2 1.1 Risk Category 2 Importance Factor (Is) Table 1.5-2 1 Mean Roof Height 30 ft Flat Roof Snow Load (pƒ) Equation 7.3-1 0.0 psf Roof Type Gable Roof Slippery Surface Slope Factor (C s) Figure 7.4-1 0.83 Building Type Enclosed Non-Slippery Surface Slope Factor (C s) Figure 7.4-1 1 Roof Live Load Roof Snow Load Equation 7.4-1 0.0 psf Existing Roof Live Load ASCE 7-16 Table 4.3-1 20 psf Reduced Snow Load (Slippery Surface) Equation 7.4-1 0.0 psf 1Roof Dead Load Asphalt Shingles 2.0 psf No Drywall 0.0 psf 5/8" Plywood Sheathing 2.0 psf Solar Panel Array 2.89 psf Roof Framing 4 psf Dead Load Without Panels 9.2 psf Insulation 1.2 psf 1Roof Dead Load is taken from the worst case scenario dead load from all arrays of the job in order to provide a more conservative evaluation. 581 E Technology Ave, C1500 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 3 of 5 2112 S Woodland Pl06/20/23 Array 1 Array Details Beam Stresses Roof Pitch 20°Beam Span 14.0'Panel Orientation Portrait Panel Quantity 4 Spacing 24.0"# of Panels on Rafter 1 Panel Area 70.33 ft²Roof Framing Type Pre-Manufac tured Truss Panel Distance From Eave 6.0" Wind Calculations - ASCE 7-16 GCp Zone 1 or 2e Figure 30.3-(2A-5B)-2.0 Kz Table 26.10-1 0.9 Kht Equation 26.8-1 1 Kd Table 26.6-1 0.85 Ke Table 26.9-1 1.0 Wind Speed (Vult) Local Design Criteria 95.0 mph Velocity Pressure Equation 26.10-1 17.68 psf Design Pressure Equation 29.4-7 g E =1.5 g a=0.74 -39.12 psf Roof Attachments: Quickbolt QB2 5/16” lag screw Shear Capacity NDS 2015 Table 12K 190.0 lbs Pullout Capacity NDS 2015 Table 12K 665.0 lbs Lag Screw Embedment 2.5" Pullout Tributary Area 30.4 ft² Shear Tributary Area 192.3 ft² Max Connection Spacing 72" Prescriptive Method: California Existing Building Code 502A.4 Total load on member without solar 10862.4 lbs Total load on member with solar 8640.67 lbs Total load increase on member 0.8% 581 E Technology Ave, C1500 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 4 of 5 2112 S Woodland Pl06/20/23 Array 2 Array Details Beam Stresses Roof Pitch 20°Beam Span 14.0'Panel Orientation Portrait Panel Quantity 6 Spacing 24.0"# of Panels on Rafter 2 Panel Area 105.5 ft²Roof Framing Type Pre-Manufac tured Truss Panel Distance From Eave 0.0" Wind Calculations - ASCE 7-16 GCp Zone 1 or 2e Figure 30.3-(2A-5B)-2.0 Kz Table 26.10-1 0.9 Kht Equation 26.8-1 1 Kd Table 26.6-1 0.85 Ke Table 26.9-1 1.0 Wind Speed (Vult) Local Design Criteria 95.0 mph Velocity Pressure Equation 26.10-1 17.68 psf Design Pressure Equation 29.4-7 g E =1.5 g a=0.68 -36.28 psf Roof Attachments: Quickbolt QB2 5/16” lag screw Shear Capacity NDS 2015 Table 12K 190.0 lbs Pullout Capacity NDS 2015 Table 12K 665.0 lbs Lag Screw Embedment 2.5" Pullout Tributary Area 33.0 ft² Shear Tributary Area 192.3 ft² Max Connection Spacing 72" Prescriptive Method: California Existing Building Code 502A.4 Total load on member without solar 10862.4 lbs Total load on member with solar 6418.95 lbs Total load increase on member 0.59% 581 E Technology Ave, C1500 | Orem, UT 84097 | 925-787-3067 | www.rightangleeng.com | Page 5 of 5 2112 S Woodland Pl06/20/23