HomeMy WebLinkAbout2303 S Bristol St #A - 101117496, 20181548, 30146629 - Plan1. THE DRAWINGS CONSTITUTE THE CONTRACT DOCUMENTS FOR CONSTRUCTION.
ALL GENERAL REQUIREMENTS ARE TO BE MET AND ALL MATERIALS, FINISHES AND
SYSTEMS ARE TO BE INSTALLED AND PERFORM PER SPECIFICATIONS UNLESS
OTHERWISE NOTED.
2. GENERAL CONTRACTOR SHALL VISIT THE SITE, REVIEW THE BUILDING DRAWINGS
AS SUBMITTED BY STARBUCKS AND BECOME THOROUGHLY FAMILIAR WITH THE
SITE CONDITIONS PRIOR TO CONSTRUCTION.
3. GENERAL CONTRACTOR SHALL CONSULT WITH STARBUCKS CONSTRUCTION
MANAGER TO RESOLVE ANY CHANGES, OMISSIONS OR PLAN DISCREPANCIES
PRIOR TO CONSTRUCTION.
4. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH LOCAL, COUNTY,
STATE AND FEDERAL CODES AND ORDINANCES.
5. GENERAL CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES.
6. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES
REQUIRED BY OTHER TRADES AND NOTIFY STARBUCKS CONSTRUCTION MANAGER
OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. ALL
DIMENSIONS ARE TO THE FACE OF THE FINISHED SURFACE UNLESS NOTED
OTHERWISE. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. DO
NOT SCALE DRAWINGS.
7. GENERAL CONTRACTOR SHALL PATCH AND REPAIR ALL EXISTING WALLS, FLOORS,
CEILINGS, OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME
DAMAGED DURING THE COURSE OF THE WORK.
8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING PERMITS FOR FIRE
PROTECTION. PLUMBING, MECHANICAL, AND ELECTRICAL SYSTEMS (IF SEPARATE
FROM BUILDING) PRIOR TO INSTALLATION OF SUCH SYSTEMS.
9. GENERAL CONTRACTOR SHALL RETAIN ONE SET OF PERMIT PLANS ON-SITE TO
DOCUMENT ALL CHANGES MADE DURING CONSTRUCTION. THE RECORD DRAWINGS
SHALL BE ISSUED TO THE OWNER AT PROJECT CLOSE-OUT AS DESCRIBED IN THE
GENERAL REQUIREMENTS OF THE PROJECT MANUAL.
10. GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING DELIVERY OF
MATERIALS FROM STARBUCKS CONTRACTED THIRD PARTY LOGISTICS
DISTRIBUTION SERVICES AND VENDOR DIRECT SHIPMENTS. SEE THE PROJECT
MANUAL FOR ADDITIONAL INFORMATION.
11. RESPONSIBILITY FOR SUPPLY AND DELIVERY OF MATERIALS AND EQUIPMENT IS
IDENTIFIED IN THE DRAWING SCHEDULE SHEETS UNDER THE COLUMN LABELED
"FURNISHED BY/RESPONSIBILITY".
12. FOR THE PURPOSE OF THE DOCUMENTS, TO “INSTALL”, SHALL MEAN TO
PROVIDE ALL FASTENERS, MISCELLANEOUS HARDWARE, BLOCKING, ELECTRICAL
CONNECTIONS, PLUMBING CONNECTIONS AND OTHER ITEMS REQUIRED FOR A
COMPLETE AND OPERATIONAL INSTALLATION, UNLESS OTHERWISE NOTED.
13. ALL ITEM SUBSTITUTIONS MUST BE APPROVED BY THE STARBUCKS CONSTRUCTION
MANAGER.
MAILING
ADDRESS:
DESIGN
MANAGER:
HESTIA ATELIER, LLP
CONTACT: ISCOLINA DELGADO
KIMBERLY SALAZAR
3 PETERS CANYON RD. SUITE 110
i.delgado@hestiaatelier.com
STARBUCKS COFFEE COMPANY
2401 UTAH AVENUE SOUTH
MS STOP: S-SD10
SEATTLE, WASHINGTON 98134
(206) 318-1575
CONSTRUCTION
MANAGER:
STARBUCKS COFFEE COMPANY
CONTACT: ISH JIMENEZ
(818)296-5027
ijimenez@starbucks.com
BECKY MORYL
rmoryl@starbucks.com
ARCHITECT
OF RECORD:
MEP
CONSULTANT
OF RECORD:
PIVOT ENGINEERING CONSULTANT
CONTACT: MOSTAFA ZUBAIR
(909) 610-5364
mzubair@peccusa.com
PROJECT
MANAGER:
STARBUCKS COFFEE COMPANY
CONTACT: ISCOLINA DELGADO
(626) 222-7669
starbuckspc@hestiaatelier.com
HESTIA ATELIER, LLP
CONTACT: HIDENORI IWAGAMI
3 PETERS CANYON RD. STE:110
IRVINE, CA 92606
(626) 222-7669
starbuckspc@hestiaatelier.com
LEGEND: X - SHEET ISSUED
R - SHEET ISSUED FOR REFERENCE AND COORDINATION ONLY
SEE TITLEBLOCK FOR REVISION ISSUE DATE(S)
SCOPE OF WORK
INTERIOR REMODEL OF EXISTING STARBUCKS COFFEE TENANT IMPROVEMENT.
SCOPE INCLUDES:
-NEW CASEWORK
-NEW NON-LOAD BEARING INTERIOR PARTITIONS
-NEW BEVERAGE PREP EQUIPMENT
-NEW PLUMBING FIXTURES
-NEW FLOOR FINISH
-NEW WALL FINISH
-CEILING MODIFICATIONS
-NEW INTERIOR LIGHTING
-NEW ARTWORK
-NEW INTERIOR FURNITURE
-MAIN ENTRY STOREFRONT DOOR RELOCATION
-NEW ACCESSIBLE AUTOMATIC DOOR ACTUATOR
-RELOCATED BUILDING SIGNAGE (UNDER SEPARATE PERMIT)
-NEW DRIVE-THRU SIGNAGE IN SAME LOCATION (UNDER SEPARATE PERMIT)
THERE ARE NO CHANGES TO OCCUPANCY TYPE OR TOTAL SQUARE FOOTAGE
OF EXISTING TENANT SPACE.
A
CODE AUTHORITIES:CITY OF SANTA ANA MUNICPAL CODE
BUILDING CODE:2022 California Building Code: Chapter 15.
PLUMBING CODE:2022 California Plumbing Code: Chapter 15.08
MECHANICAL CODE:2022 California Mechanical Code: Chapter 15.07
ELECTRICAL CODE:2022 California Electrical Code: Chapter 15.06
ENERGY CODE:2022 California Energy Code 15.17
FIRE CODE:2022 California Fire Code
HEALTH CODE:2023 California Retail Food Code
ACCESSIBILITY CODE:CH 11B OF 2022 CBC
ZONING INFORMATION:
PARCEL NUMBER:410-431-01
LEGAL DISCRIPTION:S TWP 5 RGE 10 SEC 25
PERMITTED LAND USE:COMMERCIAL
ZONING:GENERAL COMMERCIAL
CURRENT USE:COFFEE SHOP
DEFERRED SUBMITTALS:-AUTOMATIC SPRINKLER SYSTEM DRAWINGS
- FIRE ALARM SYSTEM (IF APPLICABLE)
WARNER AVE
S
B
R
I
S
T
O
L
WARNER AVE
S
B
R
I
S
T
O
L
55
55
I-5
I-5
I-405
I-405
I-405
A/C AIR CONDITIONING
ACT ACOUSTICAL CEILING TILE
ADJ ADJUSTABLE
AFF ABOVE FINISHED FLOOR
AMP AMPERE
ARCH ARCHITECT
BOH BACK OF HOUSE
CAB CABINET
CL CENTER LINE
CLG CEILING
CM STARBUCKS
CONSTRUCTION MANAGER
CTR CENTER
CX COMMISSIONING
CXA COMMISSIONING AGENT
DEG DEGREE
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DM STARBUCKS
DESIGN MANAGER
DN DOWN
EA EACH
EL ELEVATION
EQ EQUAL
EXIST EXISTING
EXT EXTERIOR
FF&E FURNITURE,
FIXTURE, AND EQUIPMENT
FLR FLOOR
FOH FRONT OF HOUSE
FOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTOR
FOIO FURNISHED BY OWNER
INSTALLED BY OWNER
FT FOOT/FEET
G GROUND
GC GENERAL CONTRACTOR
GWB GYPSUM WALLBOARD
HC HOLLOW CORE
HDW HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
HVAC HEATING, VENTILATING
AND AIR CONDITIONING
I.D. INSIDE DIAMETER
LEED LEADERSHIP IN ENERGY
AND ENVIRONMENTAL DESIGN
LL LANDLORD
LV LOW VOLTAGE
MAX MAXIMUM
MEP "MECHANICAL, ELECTRICAL
AND PLUMBING"
MFR MANUFACTURER
MIN MINIMUM
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NTS NOT TO SCALE
OC ON CENTER
O.D. OUTSIDE DIAMETER
PIR PASSIVE INFRARED SENSOR
PLC PLACE
R RADIUS
REF REFERENCE
REQ‘D REQUIRED
REV REVISION
RND ROUND
SB STARBUCKS
SC SOLID CORE
SF SQUARE FEET
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
TEMP TEMPORARY
TYP TYPICAL
UC UNDER COUNTER
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
VIF VERIFY IN FIELD
X' XX"
X
N
NORTH
ARROW
XXXX AFF
XXXXXW
XX
Scale: X =X
0 2 4 8
GRAPHIC
SCALE
DATUM
POINT
EXTERIOR
ELEVATION
CALL-OUT
INTERIOR
ELEVATION
CALL-OUT
SECTION
CALL-OUT
DETAIL
CALL-OUT
REVISION
TAG
PAINT
TAG
DESIGN ID
TAG
DOOR
TAG
WINDOW
TAG
SHEET
NOTE
CALLOUT
ABOVE FINISH
FLOOR
HEIGHT TAG
FINISH FACE TO
FINISH FACE
DIMENSION
REVISION
CLOUD
X-X-XP
T XXXXX XXXXXX XXXXXD XX
INTERIOR
WALL TAG
RESPONSIBILITY ABBREVIATIONS
SB -SUPPLIED BY STARBUCKS INSTALLED BY GENERAL CONTRACTOR
GC - SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR
CW -SUPPLIED BY CASEWORK VENDOR -INSTALLED BY VENDOR / GENERAL
CONTRACTOR
VD -SUPPLIED BY VENDOR -INSTALLED BY GENERAL CONTRACTOR
OCCUPANCY TYPE:B
TENANT AREA:2,095 SF GROSS
CONSTRUCTION TYPE:V-B
FIRE SPRINKLER:SPRINKLERED
NUMBER OF STORIES:1
STORAGE SHELVING REQUIRED:
96' RUNNING FEET, MIN. 18" DEEP.
* 3'W X TIERS HIGH
* LOWEST SHELF MIN. 6" FROM FLOOR
* UNITS MOUNTED A MIN. 1" FROM ALL WALL SURFACES.
* MUST MEET ALL REQUIREMENTS OF THE ORANGE COUNTY DEPARTMENT
OF ENVIRONMENTAL HEALTH.
PROVIDED CALCULATIONS:
* 3' LINEAR FEET, MIN. 18" DEEP.
* LENGTH OF SHELVING UNIT X # OF TIERS X # OF UNITS = MIN. 96' OR GREATER
3LF X 5 TIERS UNITS X 10 UNITS = 150 RF > 96 RF (COMPLIES)
SHEET SHEET TITLE B
I
D
S
E
T
P
E
R
M
I
T
S
E
T
R
E
V
I
S
I
O
N
1
R
E
V
I
S
I
O
N
2
R
E
V
I
S
I
O
N
3
R
E
V
I
S
I
O
N
4
GENERAL
G001 GENERAL INFORMATION
G002 COMPOSITE PLAN
G002A ENLARGED COMPOSITE PLAN
G003 LIFE SAFETY AND ACCESSIBILITY PLAN
G004 ACCESSIBILITY DETAILS
G004A ACCESSIBILITY NOTES
G004B ACCESSIBILITY NOTES
G005 SITE ACCESSIBILITY
DEMOLITION
D101 DEMOLITION FLOOR PLAN
D102 DEMO REFLECTED CEILING PLAN
ARCHITECTURAL
A001 ARCHITECTURAL SITE PLAN
A101 BUILDING FLOOR PLAN
A102 BUILDING FLOOR PENETRATION PLAN
A401 ENLARGED PLANS & ELEVATIONS
A401A ENLARGED PLANS & ELEVATIONS
INTERIORS
I101 FF & E PLAN
I102 CASEWORK PLAN
I103 REFLECTED CEILING PLAN
I103A REFLECTED CEILING DIMENSION PLAN
I103B ENLARGED SOFFIT DIMENSION PLAN
I104 FLOOR FINISH PLAN
I105 WALL FINISH PLAN
I201 INTERIOR FINISH ELEVATIONS
I202 INTERIOR FINISH ELEVATIONS
I203 INTERIOR FINISH ELEVATIONS
I204 INTERIOR FINISH ELEVATIONS
I400 ENLARGED ENGINE PLAN
I401 ENLARGED CASEWORK PLAN
I401A ENLARGED CASEWORK PLAN
I402 ENLARGED RESTROOM ACCESSIBILITY PLAN
I402A ENLARGED RESTROOM ACCESSIBILITY PLAN
I501 INTERIOR DETAILS
I501A INTERIOR DETAILS
I502 CASEWORK DETAILS
I502A CASEWORK DETAILS
I502B CASEWORK DETAILS
I503 FLOOR AND WALL FINISH DETAILS
I504 ELECTRICAL DETAILS
I504A ELECTRICAL DETAILS
I504B ELECTRICAL DETAILS
I504C ELECTRICAL DETAILS
I504D ELECTRICAL DETAILS
I505 PLUMBING DETAILS
I505A PLUMBING DETAILS
I505B PLUMBING DETAILS
I505C PLUMBING DETAILS
I601 FF&E SCHEDULES
I602 CASEWORK & FINISHES SCHEDULES
ELECTRICAL
E001 ELECTRICAL NOTES
E002 ELECTRICAL SPECIFICATIONS
E200 LIGHTING PLAN
E210 LUTRON ONE-LINE DIAGRAM
E220 LUTRON LOOP LAYOUT
E300 POWER PLAN
E310 ENLARGED ENGINE PLAN
E320 ELECTRICAL DETAILS
E330 ELECTRICAL DETAILS
E500 SINGLE LINE DIAGRAM
E510 PANEL SCHEDULES
E600 INTERIOR LIGHTING COMPLIANCE CERT
E610 INTERIOR LIGHTING COMPLIANCE CERT
E620 INTERIOR LIGHTING COMPLIANCE CERT
MECHANICAL
M-001 MECHANICAL GENERAL NOTES & LEGENDS
M-002 MECHANICAL - SCHEDULES
M-100 MECHANICAL FLOOR PLAN
M-300 MECHANICAL DETAILS
M-400 MECHANICAL T-24
MD-100 MECHANICAL DEMO FLOOR PLAN
PLUMBING
P-001 PLUMBING GENERAL NOTES & LEGENDS
P-002 PLUMBING SCHEDULES & CALCULATIONS
P-003 PLUMBING SCHEDULES & CALCULATIONS
P-100 PLUMBING WATER PLAN
P-200 PLUMBING WASTE PLAN
P-400 PLUMBING WATER ISOMETRIC
P-401 PLUMBING WASTE & VENT ISOMETRIC
P-500 PLUMBING DETAILS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAIL
P-503 PLUMBING DETAIL
PS-100 PLUMBING SITE PLAN
NUMBER OF SHEETS: 80
SHEET INDEXSYMBOLS LEGEND GENERAL NOTES ABBREVIATIONS LIST PROJECT CONTACTS
SITE INFORMATION
BUILDING INFORMATION
VICINITY PLAN
STATE OF C ALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITEC
T
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
1
1
/
1
7
/
2
0
2
3
4
:
1
0
:
1
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
G001
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
GENERAL INFORMATION
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
RESPONSIBILITY LEGEND
DRY STORAGE REQUIREMENTS
Revision Schedule
Rev Date By Description
A 11/17/23 TH PRE-SCREENING COMMENTS
Bldg# 101117496
Elec# 20181548
Plmg # 30146629
APPROVALS:
PLNG - MKilroy
BLDG - ASo
POLICE - BMartin
ELEC - MSmith
PLMG - TLuka
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
(E) MANAGER'S
EQUIPMENT
(N) HAND
SINK
(N) ICE
MACHINE/BIN
(N) 3-COMP
SINK
(N) WATER FILLING
STATION METRO
RACK/CART
G002A
1
I402
3
(E) LOCKERS
(E) 2-DR
REACH-IN
FREEZER
(E) 2-DR
REACH-IN
FRIDGE
(E) THAW
RACK (2)
(N) 1-DR REACH-
IN FREEZER
(E) METRO
RACK (10)
(E) WATER
FILLING
STATION
(E) WATER
HEATER &
RO SYSTEM
(E) SANITIZER
(N) MANAGER'S
DESK
(N) ICE
MACHINE/
BIN
(N) MERCH
DISPLAY
(N) CONDIMENT
CART
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
(E)
MOST REMOTE
POINT
2 2
2
2
2
22
2
2
2
2
I402A
1
3
3
3
3
3
3
3
3
3
1
21
(E) 1-DR
REACH-IN
FRIDGE (2)
(E) 1-DR
REACH-IN
FREEZER
(E)
(E)
(E)
(E) TRASH
BINS (3)4
4
5
5
6
6
6
7
7
1610
98
11
12
13
13
15
14
15
20
18
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
(N) PARTNER
SINK
(E) DATA
RACK
(ABOVE)
17
17
19
181
22
ADJACENT
TENANT (NIC)
3
3
(N)
A. EXISTING ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT PATH OF
TRAVEL TO REMAIN.
B. ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT BATHROOM
FIXTURES TO REMAIN.
C. WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY
PORTION OF THE EXIT ACESS, THE EXIT DOORS OR EXIT ACCESS
DOORWAYS SHALL BE PLACED IN A DISTANCE APART EQUAL TO NOT LESS
THAN ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A
STRAIGHT LINE BETWEEN EXIT DOORS OR EXIT ACCESS DOORWAYS CBC
1015.2.1.
D. ALL THRESHOLD AND FLOORING MATERIAL TRANSITIONS TO MEET
ACCESSIBILITY REQUIREMENTS ON DETAIL 7 / G-004.
E. ALL DOOR CLEARANCES PER DETAIL 6 / G-004 - U.N.O.
COMPOSITE PLAN GENERAL NOTES
COMPOSITE PLAN KEYNOTES
ACCESSIBILITY KEYNOTES
1 THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL
APPLICABLE CODES.
2 BARRIER-FREE PATH OF TRAVEL PER CBC 11B-403.5.1
3 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS.
4 60" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR
ACCESS.
5 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR.
6 POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF
PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR
WHEELCHAIR ACCESSIBILITY.
7 PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS
PER ALL APPLICABLE CODES. REFER TO DETAILS 3 & 11 / SHEET
G004.
8 TACTILE EXIT SIGN PER DETAIL 1/G004
9 INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE
REQUIRED BY APPLICABLE LAWS OR CODES. SEE 2 / G004. GC TO
PROVIDE IF NOT EXISTING
10 G.C. TO POST SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED
WHEN THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1"
HIGH ON A CONTRASTING BACKGROUND
11 EXISTING EXIT / EMERGENCY LIGHTS ABOVE TO REMAIN.
12 RELOCATED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC
906
13 EXTERIOR BARRIER FREE PATH OF TRAVEL -48" MIN
17 ACCESSIBLE RESTROOM -SEE SHEET G004 FOR MOUNTING
HEIGHTS.
18 EXISTING/NEW ENTRY/EXIT DOORS, REFER TO DETAILS 1,2 & 6 /
SHEET G004.
20 NEW AIR CURTAIN ABOVE MAIN ENTRY/EXIT.
22 NEW LUTRON PANEL ABOVE ELECTRICAL PANELS. REFER TO
ELECTRICAL DRAWINGS FOR MORE INFORMATION
19 EXISTING ELECTRICAL PANELS TO REMAIN.
14 EXISTING DOOR IS EQUIPPED WITH PANIC HARDWARE TO REMAIN
15 ACCESSIBLE DINING SURFACE AT 28" MIN-34" MAX AFF COMPLYING
WITH SECTIONS CBC 11B-226, 902
16 GC TO POST "NO SMOKING" SIGN THAT PROHIBITS SMOKING WITHIN
25 FT FROM BUILDING ENTRIES PER CALGREEN SEC. 5
21 EQUIP NEW ENTRY/EXIT DOOR WITH AUTOMATIC DOOR ACTUATORS
34
"
M
A
X
.
2'
-
1
0
"
10" - 24" MAX
46
"
M
A
X
.
3'
-
5
"
6"
30"X48" CLEAR FLOOR SPACE
1' - 0"
NOTE:
TOTAL NUMBER OF PROVIDED LOCKERS IS: 10
TOTAL NUMBER OF LOCKERS WITHIN ACCESSIBLE RANGE FOR A PARALLER
APPROACH COMPLIANT PER CODE SECTION 11B-308.3.2 IS: 6 > 5% OF THE
PROVIDED OVEALL NUMBER
OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT
REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE
FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS (22.2
N) MAXIMUM. (CBC 11B-309.4)
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
4
:
5
2
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
G002
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
COMPOSITE PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/4" = 1'-0"1ACCESSIBILITY PLAN
N
1" = 1'-0"ALOCKERS ACCESSIBILITY DETAIL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
(E) SAFE
1
(E) WARMING
OVEN (2)
(E) COMPACT
KEG DISPENSER
(E) CUP
CADDY
(E) 1-DR
U/C FRIDGE
(E) 1-DR
U/C FRIDGE
(E) 1-DR
U/C FRIDGE
(E) 1-DR
U/C FRIDGE
(E) 1-DR
U/C FRIDGE
(E) 1-DR
U/C FRIDGE
(N) 1-DR U/C
WARMING
FRIDGE
(E) 1-DR U/C
WARMING
FRIDGE
(N) 1-DR U/C
FRIDGE
(E) POS
EQUIPMENT
(N) HAND
SINK
(E) THAW
RACK
(N) DUMP
SINK
(E) BLENDER
(E) GRINDER
(E) CUP
LABELER
(ABOVE)
(E) CUP
LABELER (2)
(E) CUP
LABELER
(E) NITRO
GENERATOR
(E) NITRO
TAP
(N) PITCHER
RINSER SINK
(N) 45LBS
ICE BIN (2)
(N) ESPRESSO
MACHINE
(E) BLENDER (2)
(E) DT POS
EQUIPMENT
1
(N) MILK
DISPENSER (2)
(ABOVE)
(N) MILK
DISPENSER
(ABOVE)
(N) WARMING
WALL
(N) ICE DISPENSER
(ABOVE)
(E) CUP
CADDY
(N) CUP
CADDY
(N) HAND
SINK
(E) PASTRY
CART
(N) CLOVER
VERTICA
(N) FOOD
CASE
(N) COMBI
OVEN
(E) ESPRESSO
MACHINE
(E) ESPRESSO
MACHINE
(N) COMBO
SINK
(N) COMBO
SINK
(N) COMBO
SINK
(E) DIGITAL
PRODUCTION
MANAGER
(N) ORDER
STATUS BOARD
(N) DT
WINDOW
BACKBAR
(N) 45LBS
ICE BIN
(N) DT
WINDOW
SHELF
(N) NITRO
BADGE KIT
ENLARGED COMPOSITE PLAN KEYNOTES
1 P.O.S. HANDOFF PLANES & CONDIMENT COUNTERTOPS ARE 2'-10"
A.F.F. FOR WHEELCHAIR ACCESSIBILITY.
A. EXISTING ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT PATH OF
TRAVEL TO REMAIN.
B. ACCESSIBILE TITLE 24 PART 2 (PER 2022 CBC) COMPLIANT BATHROOM
FIXTURES TO REMAIN.
C. WHERE TWO EXITS OR EXIT ACCESS DOORWAYS ARE REQUIRED FROM ANY
PORTION OF THE EXIT ACESS, THE EXIT DOORS OR EXIT ACCESS
DOORWAYS SHALL BE PLACED IN A DISTANCE APART EQUAL TO NOT LESS
THAN ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
DIMENSION OF THE BUILDING OR AREA TO BE SERVED MEASURED IN A
STRAIGHT LINE BETWEEN EXIT DOORS OR EXIT ACCESS DOORWAYS CBC
1015.2.1.
D. ALL THRESHOLD AND FLOORING MATERIAL TRANSITIONS TO MEET
ACCESSIBILITY REQUIREMENTS ON DETAIL 7 / G-004.
E. ALL DOOR CLEARANCES PER DETAIL 6 / G-004 - U.N.O.
COMPOSITE PLAN GENERAL NOTES
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
4
:
5
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
G002A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED COMPOSITE
PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/2" = 1'-0"11ST FLOOR -ENLARGED COMPOSITE PLAN
N
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
MEANS OF EGRESS NOTES
A. EVERY ROOM OR SPACE THAT IS ASSEMBLY OCCUPANCY SHALL HAVE THE
OCCUPANT LOAD OF THE ROOM OR SPACE POSTED IN A CONSPICUOUS PLACE,
NEAR THE MAIN EXIT ACCESS DOORWAY. POSTED SIGNS SHALL BE OF AN
APPROVED LEGIBLE PERMANENT DESIGN AND SHALL BE MAINTAINED BY THE
OWNER AUTHORIZED AGENT. CBC 1004.9
B. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS
OR SIMILAR SPACES. CBC 1016.2
C. PANIC AND FIRE EXIT HARDWARE, WHERE INSTALLED ON DOORS IN THIS
BUILDING SHALL SATISFY THE FOLLOWING CBC 1010.1.10:
1) THE ACTUATION PORTION OF THE RELEASING DEVICE SHALL EXTEND AT
LEAST ONE-HALF OF THE DOOR LEAF WIDTH.
2) THE MAXIMUM UNLATCHING FORCE DOES NOT EXCEED 15 POUNDS (6.8 KG).
3) PIVOTED OR BALANCED DOORS SHALL BE OF THE PUSH-PAD TYPE WHERE
PANIC HARDWARE IS REQUIRED AND THE PAD SHALL NOT EXTEND ACROSS
MORE THAN ONE-HALF OF THE DOOR WIDTH, MEASURED FROM THE LATCH
SIDE.
4) PANIC HARDWARE LISTED IN ACCORDANCE WITH UL 305.
5) FIRE EXIT HARDWARE LISTED IN ACCORDANCE WITH UL 10C AND UL 305.
D. STRUCTURAL ELEMENTS, FIXTURES OR FURNISHINGS SHALL NOT PROJECT
HORIZONTALLY FROM EITHER SIDE MORE THAN 4 INCHES (100 MM) OVER ANY
WALKING SURFACE BETWEEN 27 INCHES (685 MM) AND 80 INCHES (2030 MM)
ABOVE THE WALKING SURFACE.
EXCEPTION: HANDRAILS SERVING STAIRS AND RAMPS ARE PERMITTED TO
PROTRUDE 4 1/2 INCHES (115 MM) FROM THE WALL. CBC 1003.3.3
E. THE PATH OF EGRESS TRAVEL EXITS AND WITHIN EXITS IN THIS BUILDING SHALL
BE IDENTIFIED BY EXIT SIGNS CONFORMING TO THE REQUIREMENTS OF CBC
SECTION 1013.1 AND AS NOTED BELOW:
1) EXIT SIGNS SHALL BE READILY VISIBLE FROM ANY DIRECTION OF EGRESS
TRAVEL.
2) EXIT SIGNS SHALL BE LOCATED AS NECESSARY TO CLEARLY INDICATE THE
DIRECTION OF EGRESS TRAVEL.
3) NO POINT IN A CORRIDOR SHALL BE MORE THAN 100 FT (30.5 M) OR THE
LISTED VIEWING DISTANCE FOR THE SIGN, WHICHEVER IS LESS, FROM THE
NEAREST VISIBLE EXIT SIGN.
F. WHERE KEY OPERATED LOCKING DEVICES ARE USED, POST A SIGN ON OR
ADJACENT TO THE REQUIRED MAIN EXIT DOOR WITH 1 INCH (25 MM) LETTERING
STATING THAT "THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS
OCCUPIED". CBC 1010.1.9.4
G. EGRESS DOORS OR GATES SHALL BE OPENABLE FROM THE EGRESS SIDE
WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. DOOR
HANDLES, PULLS, LATCHES, LOCKS AND OTHER OPERATING DEVICES SHALL BE
INSTALLED 34 INCHES (860 MM) TO 48 INCHES (1220 MM) ABOVE FINISHED
FLOOR. MANUALLY OPERATED FLUSH BOLTS OR SURFACE BOLTS ARE NOT
PERMITTED. THE UNLATCHING OF ANY DOOR OR LEAF SHALL NOT REQUIRE
MORE THAN ONE OPERATION. CBC 1010.1.9
H. LANDINGS SHALL BE PROVIDED ON EACH SIDE OF DOORS AND SUCH LANDING
SHALL BE AT THE SAME ELEVATION ON EACH SIDE OF THE DOOR LANDINGS
SHALL HAVE A WIDTH NOT LESS THAN THE WIDTH OF THE DOOR AND LENGTH
MEASURED IN THE DIRECTION OF TRAVEL OF NOT LESS THAN 44 INCHES (11120
MM). CBC 1010.1.5, 1010.1.6
KEYNOTES
1 THRESHOLDS TO BE BARRIER FREE COMPLIANT PER ALL
APPLICABLE CODES.
2 BARRIER-FREE PATH OF TRAVEL PER CBC 11B-403.5.1
3 30" (160 MM) X 48" (1220 MM) CLEAR FOR WHEELCHAIR ACCESS.
4 60" (1525 MM) DIAMETER MINIMUM TURN RADIUS FOR WHEELCHAIR
ACCESS.
5 32" (815 MM) MINIMUM CLEAR AT RESTROOM DOOR.
6 POS TRANSACTION PLANE, CONDIMENT CART TOP AND HAND-OFF
PLANE ARE 34 INCHES (860 MM) ABOVE THE FINISHED FLOOR FOR
WHEELCHAIR ACCESSIBILITY.
7 PROVIDE BARRIER-FREE SIGNAGE AT ACCESSIBLE RESTROOMS
PER ALL APPLICABLE CODES. REFER TO DETAILS 3 & 11 / SHEET
G004.
8 TACTILE EXIT SIGN PER DETAIL 1/G004
9 INTERNATIONAL SYMBOL OF ACCESSIBILITY SIGN WHERE
REQUIRED BY APPLICABLE LAWS OR CODES. SEE 2 / G004. GC TO
PROVIDE IF NOT EXISTING
10 G.C. TO POST SIGN THAT READS "THIS DOOR TO REMAIN UNLOCKED
WHEN THIS SPACE IS OCCUPIED". THE SIGN SHALL BE IN LETTERS 1"
HIGH ON A CONTRASTING BACKGROUND
11 EXISTING EXIT / EMERGENCY LIGHTS ABOVE TO REMAIN.
12 RELOCATED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC
906
13 EXTERIOR BARRIER FREE PATH OF TRAVEL -48" MIN
14 EXISTING DOOR IS EQUIPPED WITH PANIC HARDWARE TO REMAIN
15 ACCESSIBLE DINING SURFACE AT 28" MIN-34" MAX AFF COMPLYING
WITH SECTIONS CBC 11B-226, 902
LEGEND
TRAVEL DISTANCE
EMERGENCY LIGHT
X'-X" (XXMM)
EMERGENCY EXIT LIGHT/SIGN
FIRE EXTINGUISHER
ADA ACCESSIBLE SEATING
36" (915MM) X 48" (1220MM) CLEAR AREA
LOAD FACTOR:
OCC LOAD:
111 SF
8
SEATING AREA
15LOAD FACTOR:
OCC LOAD:
287 SF
5
RETAIL
60LOAD FACTOR:
OCC LOAD:
268 SF
2
BACKBAR
200
LOAD FACTOR:
OCC LOAD:
66 SF
RESTROOMS /
VESTIBULE
0
LOAD FACTOR:
OCC LOAD:
347 SF
2
WORKROOM
300
OCCUPANCY LEGEND
BACKBAR
MANAGER AREA
PARTNER REST AREA
RESTROOMS / VESTIBULE
RETAIL
SEATING AREA
WORKROOM
LOAD FACTOR:
OCC LOAD:
66 SF
RESTROOMS /
VESTIBULE
0
68'-0" FROM MOST
REMOTE POINT
LOAD FACTOR:
OCC LOAD:
61 SF
1
MANAGER AREA
150 LOAD FACTOR:
OCC LOAD:
84 SF
1
PARTNER REST AREA
150
MOST REMOTE POINT
2
2
2
2
2
22
2
2
2
2
3
3
3
3
3
3
3
3
3
1
4
4
5
5
6
6
6
7
7
10
98
11
12
13
13
15
14
15
1
3
3
SECONDARY /
EMPLOYEE EXIT
TOTAL 6
TOTAL ACCESSIBLE SEATS ( ≥ 5% ) 1
TABLE TOPS AT BANQUETTE 3 6 SEATS 2
DESCRIPTION NUMBER OF ITEMS SEATS PER ITEM
INDOOR SEATING CALCULATIONS
**RETAIL ESTABLISHMENT SERVES WATER UPON REQUEST.
*IN EACH BATHROOM OR TOILET ROOM, URINALS SHALL NOT BE SUBSTITUTED FOR MORE THAN 67% OF THE REQUIRED
WATER CLOSETS IN ASSEMBLY OCCUPANCIES.
PROVIDED 2 M 2 F 2 M 2 F
REQUIRED 1 M 1 F 1 M 1 F
1:1-50 (MALE) / 1:1-25 (FEMALE) 1:1-150 (MALE & FEMALE)FIXTURES
WATER CLOSETS LAVATORY
7 OCC. 8 OCC. 15 OCC.OCCUPANCY MALE FEMALE TOTAL
TABLE 422.1 (CPC 2022) / OCCUPANT LOAD CALCULATED PER TABLE 4-1
PLUMBING FIXTURE CALCULATIONS
MAXIMUM. TRAVEL DISTANCE PROVIDED = 68' - 0" (COMPLIES)
MAXIMUM. ALLOWABLE TRAVEL DISTANCE = 100' - 0"
NUMBER OF EXITS PROVIDED = 2
NUMBER OF EXITS REQUIRED = 1
EXITS = 72 IN. PRIMARY ENTRY, 36 IN. WORKROOM
EXIT WIDTH PROVIDED = 108 IN.
EXIT WIDTH REQUIRED - 19 OCC. x 0.2 = 3.8 IN.
EGRESS CALCULATIONS
N
PLUMBING FIXTURES OCCUPANCY CALCULATION PER TABLE 4-1 -2022 CPC:
SEATING AREA: 111/30 = 4
BACKBAR:269/200 = 2
WORKROOM:347/300 = 2
RETAIL:286/60 = 5
PATNER REST: 84/150 = 1
MANAGER AREA:61/150 = 1
GRAND TOTAL:15 OCC
N
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
0
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
G003
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
LIFE SAFETY AND
ACCESSIBILITY PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
OCCUPANCY CALCULATION
Name Area LOAD FACTOR
OCCUPANT
LOAD
SEATING AREA 111 SF 15 8
RETAIL 287 SF 60 5
BACKBAR 268 SF 200 2
RESTROOMS / VESTIBULE 66 SF 0
WORKROOM 347 SF 300 2
RESTROOMS / VESTIBULE 66 SF 0
MANAGER AREA 61 SF 150 1
PARTNER REST AREA 84 SF 150 1
GRAND TOTAL 19
1/4" = 1'-0"1EGRESS/OCCUPANCY PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
WOMEN
INDICATES MINIMUM
CLEAR SPACE AT
DOOR
DOOR STRIKE
SWING SIDE OF
DOOR BUILDING WALL
DOOR / DOOR SWING
MINIMUM REQUIRED DOOR CLEARANCE
STOREFRONT, INTERIOR OR EXTERIOR DOOR - A LEVEL AND CLEAR FLOOR OR
LANDING ON EACH SIDE OF DOOR SHALL BE PROVIDED. THE LEVEL AREA SHALL
HAVE A LENGTH IN THE DIRECTION OF DOOR SWING OF AT LEAST 60" AND THE
LENGTH OPPOSITE THE DIRECTION OF DOOR SWING OF 48" AT DOORS WITH
AUTOMATIC CLOSURES AS MEASURED AT RIGHT ANGLES TO THE PLANE OF THE
DOOR IN THE CLOSED POSITION
1' - 0"
4'
-
0
"
1' - 6" CLR. @ INTERIOR DOORS
2' - 0" CLR. @ EXTERIOR DOORS
4' - 0"
5'
-
0
"
5' - 0"
LEVER HANDLE
NOTE:
CBC SECTION 11B-703
ANSI A117.1, 703.3.10, 703.4.5
ROOM IDENTIFICATION
SIGNAGE SEE 11/-
TO
B
O
T
T
O
M
O
F
C
H
A
R
A
C
T
E
R
60
"
M
A
X
.
BO
T
T
O
M
O
F
B
R
A
I
L
L
E
48
"
M
I
N
.
-
6
0
"
M
A
X
.
HEIGHT OF TACTILE SIGNS AND BRAILLE:
TYPICAL AT EXITS AND RESTROOMS
34
"
M
I
N
.
T
O
4
4
"
M
A
X
.
58
"
M
I
N
.
T
O
6
0
"
M
A
X
.
A
.
F
.
F
.
MAX.
9"
TEXT: 5/8" MIN. - 2" MAX.
PARTIAL SIGNAGE SECTION AND MOUNTING SPECIFICATIONS
FACE OF TOILET ROOM DOOR
CENTER OF
SIGNAGE
IDENTIFYING SIGNAGE
TOILET ROOM IDENTIFYING SIGNAGE
DOUBLE STICK MOUNTING FOAM
58
"
-
6
0
"
A
.
F
.
F
.
1/4" THICK ACRYLIC PLASTIC-
IMAGE AND LETTERS SHALL BE
ENGRAVED (MIN. 1/32" DIST.)
INTO PLAQUE SURFACE.
SYMBOLS AND LETTERS SHALL
BE DIFFERENT FROM THE
DOOR IN COLOR AND
CONTRAST.
SUBSURFACE IMAGES SHALL
BE CENTERED ON PLAQUE.
UNISEX
WOMEN
MEN
1' - 0"
1' - 0"
1' - 0"
LIGHT SWITCH
THERMOSTATSEAT COVER &
TISSUE DISPENSER
AND / OR NAPKIN
DISPOSAL
GRAB BAR
PROTRUSION 14"
MIN. OUTWARD INSULATE HOT WATER &
DRAIN PIPES
OPERATING
DEVICE HEIGHT
MIRROR - 40" MAX. TO BOTTOM
EDGE OF REFLECING SURFACE
SOAP
DISPENSER
PAPER TOWEL
DISPENSER
44
"
M
A
X
.
40
"
MA
X
.
33
"
-
3
6
"
19
"
M
A
X
.
17
"
M
I
N
.
1'
-
5
"
M
A
X
.
R
I
M
H
E
I
G
H
T
LAVATORYURINAL
WATER CLOSET
SIDE
WATER CLOSET
FRONT
MA
X
.
34
"
MI
N
.
27
"
OUTLET OVER
COUNTER
OUTLET
BO
T
.
F
I
X
T
.
15
"
M
I
N
.
T.
O
.
F
I
X
T
.
48
"
M
A
X
.
ELECTRICAL
18" MAX.
17" MIN.
MIN.
1' - 0"
MIN.
2' - 0"
7"-9"
MI
N
.
1
1
/
2
"
HARDWARE / EFFORT
CBC 11B-404.2.7 / 11B-404.2.9
TYPE OF HARDWARE: PUSH / PULL
HARDWARE MUST BE CENTERED BETWEEN 34"
AND 44" A.F.F.
MAX. EFFORT FOR INT. / EXT. DOOR - 5 LBS.
SMOOTH SURFACE PER
CBC SECTION 11B- 404.2.10
10" KICKPLATE OR SMOOTH SURFACE FULL
WIDTH OF DOOR
THRESHOLDS
CBC SECTION 11B-404.2.5
1/2" HIGH MAX. THRESHOLD
1/4" PER FOOT MAX. SLOPE
DOOR SIZE
CBC SECTION CBC 11B-404.2.3
3'-0" WIDE
6'-8" HEIGHT
32" CLEAR WIDTH
90 DEGREE DOOR OPENING
EXTERIORINTERIOR
CL
1/
2
"
M
A
X
.
10
"
M
I
N
.
34" TO 44" A.F.F.
MAX.
0'-0" FIN. FLR.
LETTERS - 5/8" MIN. - 2"
MAX. - 1/32" RAISED
TEXT AND ASSOCIATED BRAILLE SHALL READ AS INDICATED IN THE DRAWING AND
PER CBC SECTTION 1011 & ANSI 117.1, 703.3.10, 703.4.5
EXIT 3"
M
I
N
.
. .. .. ... . . . ...
BRAILLE PER CBC
11B-703.3.2
5'
-
0
"
(
6
0
"
)
M
A
X
.
FIN. FLR.
4'
-
0
"
(
4
8
"
)
M
I
N
.
EXIT EXIT... .. ... ... .. ...
THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO
IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY
DISABLED PERSONS.
THE SYMBOL SPECIFIED ABOVE SHALL CONSIST OF A WHITE FIGURE ON A BLUE
BACKGROUND. THE BLUE SHALL BE EQUAL TO COLOR NO. 15090 IN FEDERAL
STANDARD 595B.
6"
6"
1/8 " STEEL BACKING
PLATE - WELD TO (3) STUDS
MINIMUM
METAL SPACER
INTERIOR FINISH - SEE
ELARGED TOILET PLAN AND
FINISH SCHEDULE
1 1/2 " O.D.
GRAB BAR
(N
.
T
.
S
.
)
33
"
M
I
N
.
T
O
3
6
"
M
A
X
FIN. FLR.
1 1/2"
TOP OF GRIPPING
SURFACE
CLEAR KNEE SPACE
WALL MOUNTED LAVATORY
19 " MAX
17" MIN.
34
"
M
A
X
.
29
"
M
I
N
.
9"
M
I
N
.
6" MAX.
8" MIN.
KNEE CLEARANCE
OF
R
E
F
L
E
C
T
I
V
E
S
U
R
F
A
C
E
40
"
M
A
X
.
T
O
B
O
T
T
O
M
INSULATION AROUND PIPE
27
"
M
I
N
.
11" MIN.
(30" MIN.)
2' - 6"
(4
8
"
M
I
N
.
)
4'
-
0
"
(1
9
"
M
I
N
.
)
1'
-
7
"
TABLE TOP @ +34" A.F.F.
(28" MIN. - 34" MAX.)
30" X 48" CLEAR
FLOOR SPACE
27
"
M
I
N
80
"
M
I
N
4" MAX
15
"
M
I
N
48
"
M
A
X
48
"
M
A
X
20" MAX
44
"
M
A
X
>20"-25" MAX
46
"
M
A
X
34
"
M
A
X
>10"-24" MAX
34
"
M
A
X
10" MAX
48
"
M
A
X
15
"
M
I
N
48
"
M
A
X
10" MAX
42"MINIMUM
33
"
-
3
6
"
M
A
X
.
24" MIN.
33
"
-
3
6
"
M
A
X
.
36" MIN.
12"
MAX.
TO TOP OF GRAB BAR
17" MIN. / 18" MAX. TO
CENTERLINE OF WATER
CLOSET
REINFORCEMENT
BACKING - TYP. - SEE
DETAIL 5 / SHEET G-003
GRAB BAR LENGTH
PROVIDE 1-1/2" MIN.
BETWEEN TOP OF TANK
AND BOTTOM OF GRAB BAR
12"
MIN
.
24"
MIN
.
1/4" = 1'-0"6MINIMUM DOOR CLEARANCE
1/2" = 1'-0"3ACCESSIBLE RESTROOM SIGNAGE1" = 1'-0"11RESTROOM IDENTIFYING SIGNS
1/4" = 1'-0"4ACCESSIBLITY FOR ACCESSORIES - STANDARD MOUNTING HEIGHTS
12" = 1'-0"7ENTRANCE DOOR ADA DETAIL
12" = 1'-0"1TACTILE EXIT SIGN
3" = 1'-0"2INTERNATIONAL ACCESSIBILITY SYMBOL
6" = 1'-0"5TOILET GRAB BAR13/4" = 1'-0"9KNEE SPACE AT LAVATORY
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
0
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
G004
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ACCESSIBILITY DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"13KNEE SPACE AT TABLE1/2" = 1'-0"17UNOBSTRUCTED PATH OF TRAVEL
3/4" = 1'-0"18UNOBSTRUCTED FORWARD REACH
3/4" = 1'-0"15OBSTRUCTED HIGH FORWARD REACH
3/4" = 1'-0"16OBSTRUCTED SIDE REACH
3/4" = 1'-0"14UNOBSTRUCTED SIDE REACH 12" = 1'-0"8GRAB BAR REINFORCEMENT
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
1
0
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
G004A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ACCESSIBILITY NOTES
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
AUTOMATIC DOORS
1. AUTOMATIC DOORS SHALL COMPLY WITH C.B.C.SECTION 11B-404.3
2. FULL-POWERED AUTOMATIC DOORS SHALL COMPLY WITH ANSI/BHMA
A156.10. LOW -ENERGY AND POWER ASSISTED DOORS SHALL COMPLY
WITH ANSI/BHMA A156.19
3. THE MIMINUM CLEAR WIDTH FOR AUTOMATIC DOOR SYSTEMS IN A
DOORWAY SHALL PROVIDE A CLEAR UNOBSTRUCTED OPENING OF 32
INCHES MINIMUM WITH ONE LEAF POSITIONED AT AN ANGLE OF 90
DEGREES FROM ITS CLOSED POSITION.
4. CLEARANCES AT POWER ASSISTED DOORS AND AUTOMATIC DOORS
SERVING AN ACCESSIBLE MEANS OF EGRESS SHALL COMPLY WITH C.B.C.
11B-404.2.4
5. THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS WITH AUTOMATIC
DOORS SHALL COMPLY WITH CBC 11B-404.2.5
6. MANUALLY OPERATED ACTUATOR CONTROLS FOR AUTOMATIC DOORS
SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST. THE FORCE REQUIRED
TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM.
7. THE CLEAR FLOOR SPACE ADJACENT TO THE CONTROL SHALL BE
LOCATED BEYOND THE ARC OF THE DOOR SWING AND SHALL COMPLY
WITH C.B.C. 11B-305
8. AUTOMATIC DOOR OPERABLE PARTS SHALL BE PLACED WITHIN ONE OR
MORE OF THE REACH RANGES SPECIFIED IN C.B.C. 11B-308
9. WHERE DOORS AND GATES WITHOUT STANDBY POWER ARE PART OF A
MEANS OF EGRESS, THE CLEAR BREAK OUT OPENING AT SWINGING OR
SLIDING DOORS AND GATES SHALL BE 32 INCHES MINIMUM WHEN
OPERATED IN EMERGENCY MODE, UNLESS MANUAL SWINGING DOORS
AND GATES COMPLY WITH C.B.C 11B-404.2 AND SERVE THE SAME MEANS
OF EGRESS.
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
1
2
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
G004B
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ACCESSIBILITY NOTES
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
ACCESSIBILITY SITE PLAN KEYNOTES
1 EXISTING PARKING STALL TO REMAIN
2 EXISTING ACCESSIBLE PARKING -RESTRIPE PER DETAIL 15 / G005
3 EXISTING VAN ACCESSIBLE PARKING & ACCESSIBLE AISLE -
RESTRIPE & REGRADE PER DETAIL 15 / G005
4 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO PUBLIC RIGHT OF
WAY & ACCESSIBLE PARKING
5 EXISTING INTERNATIONAL SYMBOL FOR PARKING -REFER TO 13 /
G005
6 EXISTING TRASH ENCLOSURE TO REMAIN
7 UPDATE EXISTING STARBUCKS DRIVE THRU SIGNAGE/EQUIPMENT
WITH EXISTING FOOTING
8 EXISTING PUBLIC RIGHT OF WAY
9 EXISTING DRIVE-THRU LANE TO REMAIN.
10 EXISTING LANDSCAPE AREA TO REMAIN
11 EXISTING ADJACENT TENANT. (NIC)
12 EXISTING DETECTABLE WARNINGS TO REMAIN
13 EXISTING ACCESSIBLE PARKING SIGNAGE PER DETAIL 14/G005
14 EXISTING TOWAWAY SIGN TO REMAIN. SHOWN IN DETAIL 20/G005
15 NEW GREASE INTERCEPTOR. REFER TO PLUMBING FOR MORE INFO.
16 PROVIDE NEW PEDESTRIAN CROSSING CAUTION SIGN. (4)
6'
-
8
"
A
.
F
.
F
.
+3
6
"
W
A
L
L
M
O
U
N
T
E
D
TEXT SHALL NOT BE LESS
THAN 1 INCH IN HEIGHT
NOTE:
1. CONTRACTOR SHALL VERIFY THE ADDRESS AND PHONE NUMBER
INDICATED ON SIGN PRIOR TO THE PRINTING OF SIGNS.
2. THE ADDRESS AND PHONE NUMBER SHALL BE IMPRINTED ON THE
SIGN BY THE SIGN COMPANY.
3. THIS SIGN SHALL BE PLACED AT THE ENTRANCE TO OFF-STREET
PARKING FACILITIES.
THE NAME, ADDRESS AND PHONE
NUMBER SHALL BE IMPRINTED ON
THE SIGN BY THE SIGN COMPANY
UNAUTHORIZED VEHICLES
PARKED IN DESIGNATED
ACCESSIBLE SPACES NOT
DISPLAYING
DISTINGUISHING
PLACARDS OR SPECIAL
LICENSE PLATES ISSUED
FOR PERSONS WITH
DISABILITIES WILL BE
TOWED AWAY AT THE
OWNER'S EXPENSE.
TOWED VEHICLES MAY BE
RECLAIMED AT
(---ADDRESS---)
OR BY TELEPHONING
(XXX) XXX-XXXX
17" MIN.
2' - 0"
22
"
M
I
N
.
2'
-
7
"
HATCH AREA INDICATES
TRUNCATED DOMES PER DETAIL
18 / SHEET G005 SEE NOTE BELOW
10% MAX
SLOPE
10% MAX
SLOPE
CONCRETE
CURB
8.
3
3
%
MA
X
SL
O
P
E
NOTE:
RAMPS WITHOUT A 3'-0" WIDE LEVEL LANDING - PROVIDE
TRUNCATED DOMES ALONG ENTIRE RAMP SLOPE
FLARED SLOPE
4' - 6 1/2"
CL
E
A
R
4'
-
5
"
M
I
N
.
0.90"
AT
BASE
0.45"
AT TOP
0.
2
0
H
T
.
TYPICAL PLAN
TYPICAL SECTION A
A
-
NOTE:
1. DETECTABLE WARNING SURFACES SHALL BE YELLOW CONFORMING TO FS 33538
OF FEDERAL STANDARD 595C." (CBC, Sec. 11B-705.1.1.3). MATERIAL SHALL BE
INTEGRAL PART OF THE WALKING SURFACE.
2. DETECTABLE WARNING SURFACES SHALL CONTRAST VISUALLY WITH ADJACENT
WALKING SURFACES EITHER LIGHT-ON-DARK OR DARK-ON-LIGHT. THE MATERIAL
USED TO PROVIDE CONTRAST SHALL BE AN INTEGRAL PART OF THE SURFACE."
(CBC, SEC. 11B-705.1.1.3).
3. ONLY APPROVED DSA-AC DETECTABLE WARNING PRODUCTS AND DIRECTIONAL
SURFACES SHALL BE INSTALLED AS PROVIDED IN THE CALIFORNIA CODE OF
REGULATIONS (CCR), TITLE 24, PART 1, CHAPTER 5, ARTICLE 2, 3 AND 4." (CBC,
SEC. 11B-705.3).
2.
3
5
"
2.35"
ADDITIONAL SIGN REQUIRED
AT
VAN ACCESSIBLE SPACES
WHITE TEXT ON BLUE
REFLECTIVE BACKGROUND
1/4" WIDE BORDER LINE AT
ALL SIDES
WHITE OCCUPANT ON DARK
BLUE BACKGROUND
METAL SIGN WITH ROUNDED
CORNERS CORNERS
3" HIGH TEXT - 1/2" WIDE STROKE
2" HIGH TEXT - 3/8" WIDE STROKE
1. ALL PARKING SPACE SIGNS, IN CALIFORNIA, CONSTRUCTED ON OR AFTER JULY
1, 2008, SHALL INCLUDE THE VERBAGE "$250 MINIMUM FINE". CALIFORNIA
VEHICLE CODE SECTION 22511.8 (AB1511), CBC 11B-502.6.2
2. 70 SQ. INCH MINIMUM ACCESSIBLE SIGN PER CBC 11B-502.6
MATCH CENTER SPECIFICATION
FOR SIGNAGE CONSTRUCTION
AND MATERIALS
1' - 0"
60
"
W
A
L
L
M
O
U
N
T
E
D
6'
-
8
"
M
I
N
.
P
O
L
E
M
O
U
N
T
E
D
2'
-
0
"
60
"
W
A
L
L
M
O
U
N
T
E
D
6'
-
8
"
M
I
N
.
WH
E
R
E
O
C
C
U
R
S
ACCESSIBLE ROUTE CROSSWALK
STRIPING. 4" WIDE PAINTED BLUE
STRIPES, OVER YELLOW HIGHWAY
PAINT (2 COATS) WITH DIAGONAL
STRIPING AT 3'-0" O.C.
NOTE:
ALL SLOPE CONDITIONS SHALL COMPLY
WITH ACCESSIBLE ROUTE CRITERIA PER
STATE OF CALIFORNIA TITLE 24.
3' -
0
"
5' - 0"
WHITE PAINTED BORDER AND
SYMBOL OVER BLUE
BACKGROUND (COLOR NO. 15090
IN FEDERAL STANDARD 595a)
4" TYP.3' - 0"4" TYP.
3'
-
0
"
NOTE:
SLOPE IN STALL & LOADING ZONE NOT TO EXCEED 2% IN ANY DIRECTION
NO PARKING
INTERNATIONAL SYMBOL OF
ACCESSIBILITY - REFER TO DETAIL
13 / SHEET G-005
4" WIDE STRIPED LOADING ZONE -
12" HIGH LETTERS READING "NO-
PARKING" SHALL BE PAINTED
WITHIN THE LOADING ZONE AREA-
PAINT COLOR: WHITE
CONCRETE CURB
4" WIDE PARKING STALL PAVEMENT
STRIPING-COLOR (BLUE) PER ADA
REQUIREMENTS
ACCESSIBLE CURB RAMP SEE
DETAIL 16 / SHEET G-005
PRE-CAST CONCRETE WHEEL STOP
ACCESSIBLE PARKING SIGNAGE
PER DETAIL 14 / SHEET G-005
SL
O
P
E
1/
4
"
P
E
R
FT
.
M
A
X
.
SL
O
P
E
1/
4
"
P
E
R
FT
.
M
A
X
.
SLOPE
1/4" PER
FT. MAX.
SLOPE
1/4" PER
FT. MAX.
VAN ACCESSIBLE
9' - 0" MIN.
MIN.
8' - 0"
MIN.
9' - 0"
O.C.3' -
0
"
18
'
-
0
"
T
O
T
A
L
S
T
A
L
L
L
E
N
G
T
H
2'
-
0
"
T
Y
P
.
ACCESSIBLE UNOBSTRUCTED PATH OF TRAVEL 48" MIN
WIDTH (UNLESS NOTED OTHERWISE) WITH SLOPE NOT TO
EXCEED 5% IN DIRECTION OF TRAVEL AND CROSS SLOPE
NOT TO EXCEED 2%
LEGEND
1
1
1
1
1
1
1
1
1
1
1
2
3
4
4
4
5
5
6
7
7
8
8
8
8
8
9
9
10
10
10
10 10
10
1010
10
10
10 101010
10 10 10
10
10
10
10
11
ADJACENT TENANT
12
13
13
14
15P21669
P X0022
Y 23113
S 22544
Y 23115
S 23071
S 23077
7
S X2129716
16
1616
9
10
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
1
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
G005
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
SITE ACCESSIBILITY
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1" = 1'-0"20EXISTING SITE ACCESSIBILITY SIGNAGE 1/4" = 1'-0"16EXISTING CURB RAMP
3" = 1'-0"18TRUNCATED DOMES 3/4" = 1'-0"14ACCESSIBLE PARKING SIGN
1/4" = 1'-0"17H.C. ACCESS ROUTE 3/4" = 1'-0"13ACCESSIBLE SYMBOL
N
1/8" = 1'-0"15EXISTING ACCESSIBLE PARKING (REGRADED & REPAINTED)
1/16" = 1'-0"1ACCESSIBILITY SITE PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. GENERAL CONTRACTOR TO VERIFY ALL EXISTING ELEVATIONS AND BUILDING
CONDITIONS IN FIELD PRIOR TO START OF CONSTRUCTION.
B. PROVIDE DETECTABLE WARNING (IF APPLICABLE PER LOCAL CODE) AT
TRANSITION FROM SIDEWALK TO DRIVE AISLE.
C. ACCESSIBLE PARKING SPACES AND ACCESS AISLES SHALL HAVE SURFACE
SLOPE NOT TO EXCEED 2% IN ALL DIRECTIONS.
D. REFER TO ELECTRICAL DRAWINGS FOR SITE RELATED ELECTRICAL WORK.
(WHEN APPLICABLE)
E. EXISTING SITE FEATURES TO REMAIN, NO CHANGE U.N.O
GENERAL NOTES
SITE PLAN KEYNOTES
1 EXISTING LANDSCAPED AREA TO REMAIN.
4 EXISTING ACCESSIBLE PARKING TO REMAIN. REFER TO 1/G005 FOR
MORE INFORMATION
5 EXISTING PARKING STALL TO REMAIN.
6 EXISTING PROPERTY LINE TO REMAIN, NO CHANGE.
7 EXISTING PUBLIC RIGHT OF WAY
8 EXISTING TRASH ENCLOSURE TO REMAIN. EXISTING DEDICATED
AREA FOR RECYCLING.
2 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO ACCESSIBLE
PARKING -REFER TO 1/G005.
10 NEW GREASE INTERCEPTOR. REFER TO PLUMBING DRAWINGS FOR
MORE INFORMATION
15 EXISTING DIGITAL ORDER SCREEN TO REMAIN.
12 NEW DT DIRECTIONAL EXIT/THANK YOU SIGN -TO BE ANCHORED TO
EXISTING FOOTING. (UNDER SEPARATE PERMIT SUBMITTAL)
13 NEW CLEARANCE BAR -TO BE ANCHORED TO EXISTING FOOTING.
(UNDER SEPARATE PERMIT SUBMITTAL)
14 NEW WAYFINDING PAVEMENT GRAPHICS.
16 EXISTING DT 5-PANEL MENU BOARD TO REMAIN.
17 EXISTING NON-ILLUMINATED BOLLARD TO REMAIN.
11 NEW DT DIRECTIONAL ARROW SIGN -TO BE ANCHORED TO
EXISTING FOOTING. (UNDER SEPARATE PERMIT SUBMITTAL)
9 STARBUCKS, AREA OF WORK.
3 EXISTING ACCESSIBLE PATH OF TRAVEL FROM/TO PUBLIC RIGHT OF
WAY -REFER TO 1/G005.
18 EXISTING PRE-MENU PREVIEW TO REMAIN.
19 PROVIDE NEW PEDESTRIAN CROSSING CAUTION SIGN. (4)
A
EXISTING LANDSCAPE AREA
LEGEND
EXISTING 6" (150MM) CONCRETE CURB
ACCESSIBLE PATH OF TRAVEL
S 23071
S 23115
S 23113
S 22544
S 23077
1
ADJACENT TENANT
1
1
1 1
111
1
1
1
11
1
1
1
1 1
1
1
1
1
77
7
7
7
2
3
3
3 3
3
4
5
5
5
5
5
5
5
5
66
6
6
6
6 6
6
6
8
9
P 21669
P X0022 10
11
12
13
14
14
1516
18
17 17
17
17
PL
PL
PLPL
PL
PL
PL
PL PL
PL
6
19
19
19
19
A
A
A
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
1
7
/
2
0
2
3
4
:
0
9
:
4
8
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
A001
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ARCHITECTURAL SITE
PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
N
1" = 10'-0"1ARCHITECTURAL SITE PLAN
Revision Schedule
Rev Date By Description
A 11/17/23 TH PRE-SCREENING COMMENTS
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
KEYNOTES GENERAL NOTES
A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION.
ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT.
B. GENERAL CONTRACTOR TO PROVIDE FIRE TREATED WOOD STUD BLOCKING,
OR EQUIVALENT TO SUPPORT ANY WALL ATTACHMENT AND/OR SIGNAGE.
C. IF EXISTING EXTERIOR ENTRANCE THRESHOLD EXCEEDS MINIMUM BARRIER
FREE PROVISION OF THE CODE, REMOVE AND REPLACE WITH ACCESSIBLE
THRESHOLD. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES AT
ACCESSIBLE DOORWAYS TO BE BEVELED WITH A SLOPE NO GREATER THAN
1:12.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNLESS SHOWN OR NOTED
OTHERWISE.
E. GENERAL CONTRACTOR TO PROVIDE WATER RESISTANT TYPE 'X' GYP. BD. AT
RESTROOM AND BACKBAR WALLS (ALL WET WALLS).
F. ALL DOORS SHALL BE 32” (815MM) MINIMUM CLEAR OPENING WHEN OPENED TO
90 DEGREE POSITION UNLESS OTHERWISE NOTED.
G. SEE SHEET A601 OR I601 FOR EXTERIOR DOOR AND WINDOW SCHEDULES.
H. STARBUCKS VENDOR TO PROVIDE DOOR HARDWARE COMPONENTS AND GC
TO INSTALL.
I. VERIFY ALL EXISTING DOORS, HARDWARE AND FRAMES MEET STARBUCKS
AND/OR CODE REQUIREMENTS.
J. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM THE
CITY.
K. SEE STRUCTURAL FOR KNEE WALL BRACING IF APPLICABLE.
L. SEE SHEET A501 FOR BUILDING DETAILS IF APPLICABLE.
M. REFER TO SHEET I104 FOR FLOOR FINISHES.
N. PATCH AND REPAIR WALLS AS NECESSARY TO PROVIDE A FINISH READY
SURFACE.
3 G.C. TO PROVIDE AND INSTALL 6" CONCRETE CURB AT SAFE -CURB
NOT TO EXCEED FOOTPRINT OF SAFE.
1 PROVIDE ADEQUATE REINFORCEMENT AND / OR BLOCKING AS
REQUIRED TO SUPPORT WALL ATTACHMENTS -REFER TO WALL
BLOCKING KEY.
7 EXISTING ELECTRICAL PANELS TO REMAIN.
8 DIMENSION CONTROL DATUM POINT.
12 NEW RESTROOM DOOR. FINISH PER ELEVATIONS
10 ELECTRICAL PANEL LOCATIONS. MAINTAIN MINIMUM CLEARANCE
AS REQUIRED BY CODE.
9 OUTLINE OF BAR PER CASEWORK MANUFACTURER.
11 ALIGN FACE OF FINISHED WALL.
13 NEW ENTRY/EXIT DOOR.
15 NEW MOP SINK AND RO SYSTEM CONCRETE PLATFORM.
16 DASHED LINE INDICATES HEADER ABOVE
17 NEW TRAFFIC SWINGING DOOR. NO LATCH OR LOCK PROVIDED
2 G.C. TO PROVIDE AND INSTALL 6" CONCRETE CURB AT FOOD CASE -
CURB NOT TO EXCEED FOOTPRINT OF CASE.
4 G.C. TO PROVIDE AND INSTALL 10" CONCRETE CURB AT MOP SINK
RO SYSTEM.
5 EXISTING STOREFRONT TO REMAIN.
18 NEW DRIVE-THRU WINDOW.
6 NEW STOREFRONT.
14 EXISTING EXIT DOOR TO REMAIN.
GENERAL LEGEND
NEW FULL HEIGHT WALL
EXISTING WALL
WALL BLOCKING CALL-OUT-
X WALL TYPE TAG
WALL BLOCKING KEY
SYMBOL ITEM
128 LBS
(58 KG)
WEIGHT
36" TO 40"
(915MM TO 1015MM)
HEIGHT A.F.F.
30" (760MM) BEHIND SINK
APPROX. WIDTH
SHELVES ABOVE
COMPARTMENT SINK
200 LBS
(91 KG)
48" TO 76"
(1220MM TO 1930MM)
96" (2440MM) CENTERED ABOVE
COMPARTMENT SINK
BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR
SHELVES AT
MANAGER'S DESK
300 LBS
(136 KG)
32" TO 96"
(810MM TO 2440MM)
48" (1220MM) 3/4 (19MM) ACX
PLYWOOD, CENTERED ON SHELVES
30" TO 36"
(760MM TO 915MM)
60" (1525MM) AROUND WATER
CLOSET
200 LBS
(91 KG)
COMMERCIAL INSTALLATION REQUIRES CONCEALED
ARM CARRIER. REFER TO MFR'S SPECIFICATION.
200 LBS
(91 KG)
BLOCKING SPECIFICATION TO BE PROVIDED BY VENDOR.
COORDINATE LOCATION AND EXTENT WITH PENTAIRTBD BY
VENDOR
WORKROOM
HAND SINK
RESTROOM
GRAB BARS
RESTROOM
HAND SINK
UPPER CBE SIREN /
ICE SYSTEM
WATER HEATER /
FILTRATION SYSTEM
A
B
C
D
G
H
K
M
BLOCKING PER DETAIL X/I50X
DIGITAL MENU
BOARDS
ORDER STATUS
BOARDO
DATA RACK AT
WORKROOM
300 LBS
(136 KG)
44" TO 96"
(1120MM TO 2440MM)
28" (710MM) 3/4 (19MM) ACX
PLYWOOD, CENTERED ON RACKF
SHELVES AT
PARTNER REST AREA
300 LBS
(136 KG)
32" TO 96"
(810MM TO 2440MM)
48" (1220MM) 3/4 (19MM) ACX
PLYWOOD, CENTERED ON SHELVESE
BLOCKING SPECIFICATION FOR ICE MACHINE DIVERTER.
REFER TO VENDOR'S SPECIFICATION AND DETAILS.
ICE MACHINE
DIVERTER BLOCKINGI
45" TO 63 1/2"
(XXXMM TO XXXMM)
TBD BY
VENDORWARMING SHELVES 1' - 1 5/8" (XXMM) - PER SHELFJ
BLOCKING PER DETAIL X/I50X N
LOCKERS
TBD BY
VENDOR
CUP DISPENSERL 44 5/8" TO 70 1/2"
(XXXMM TO XXXMM)1' - 11 3/4" (XXMM)
BLOCKING PER DETAIL X/I50XDT UPPER CABINETP
1 NEW FULL HEIGHT WALL
3 5/8" X 20 GA. METAL STUDS @16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON BOTH
SIDES TO 6" ABOVE CEILING - USE
WATER RESISTANT GYP. BD. ON WET
WALLS - DRYWALL SCREWS @ 12" O.C.
9,13
SEE WALL STUD TABLE SHEET I501
WALL TYPES
I501
NEW FURRED FULL HEIGHT WALL
3 5/8" X 20 GA. METAL STUDS @ 16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON ONE
SIDE TO 6" ABOVE CEILING - USE WATER
RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12" O.C.
3
FINISH MAY OCCUR-
SEE WALL FINISH PLAN
& INTERIOR
ELEVATIONS - TYP.
NEW PLUMBING WALL
6" X 20 GA. METAL STUDS @ 16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON BOTH
SIDES TO 6" ABOVE CEILING - USE
WATER RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12" O.C.
2 9,13
I501
9,13
I501
NEW FURRED PLUMBING WALL
6" X 20 GA. METAL STUDS @ 16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON ONE
SIDE TO 6" ABOVE CEILING - USE WATER
RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12" O.C.
NEW FURRED FULL HEIGHT WALL
3 5/8" X 20 GA. METAL STUDS @ 16" O.C.
WITH 5/8" TYPE "X" GYP. BD. ON ONE
SIDE TO 6" ABOVE CEILING - USE WATER
RESISTANT GYP. BD. ON ALL WET
WALLS - DRYWALL SCREWS @ 12" O.C.
4
16,19
I501
5 I501
EXISTING WALL
EXISTING WALL
16,19
12' - 3 3/4"
20' - 10 1/4"
29' - 3"
30' - 11 1/2"
19' - 10 1/2"
13' - 9 3/4"
2'
-
8
1
/
2
"
12
'
-
1
1
1
/
4
"
21
'
-
1
0
1
/
2
"
23
'
-
1
1
1
/
2
"
26
'
-
0
1
/
4
"
12
'
-
1
1
/
4
"
19
'
-
3
"
8' - 5"
11' - 0 3/4"
CL
R
(
F
.
O
.
F
.
)
8'
-
2
"
CLR (F.O.F.)
8' - 0"
CL
R
(
F
.
O
.
F
.
)
8'
-
2
"
CLR (F.O.F.)
8' - 0"
3' - 8 1/2"3' - 0"12' - 3 3/4"
4' - 10 3/4"3' - 0"2 3/4"
13' - 3 1/2"
CLR (F.O.F.)
3' - 2"
8"
CLR (F.O.F.)
3' - 2"
CLR
6' - 10 1/2"
CLR
5' - 9 1/4"
2 3/4"3' - 0"4' - 10 3/4"
6'
-
0
"
13
'
-
5
3
/
4
"
1
1
11
1
2
2
1
1
2
1
4
3
3
5
5
2
3
B
M
I
H
GH
G
G
G
J
O
N
P K
D
J
A
C
E
F
2
3
4
.
.
.
..
.
5'
-
6
1
/
2
"
7
8
9
99
10
11
12 D 10190 15
12D10190 05
13 D 10449 16
14
15
16
16
L
16
17
18
W 21987
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
5
6
5
6 5
5
A401
1
A401A
1
D 10086 14
1 1
1
1
1
1
1
CLR.
5' - 0"CL
R
.
6'
-
0
"
8'
-
7
"
8'
-
9
1
/
4
"
A401
9
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
3
2
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
A101
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
BUILDING FLOOR PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
N
1/4" = 1'-0"1FLOOR PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. ALL STUB-UP DIMENSIONS ARE RELATIVE TO FINISHED WALL LOCATIONS
(SHOWN AS OUTLINES ON THIS PLAN). REFER TO FLOOR PLAN FOR WALL
PLACEMENT.
B. FLOOR SINK: REFER TO CUT SHEETS FOR COMPONENT SPECIFICATIONS AND
CUTOUT REQUIREMENTS.
C. WASTE LINE PENETRATIONS: REFER TO PLUMBING PLANS FOR INDIVIDUAL LINE
LOCATIONS.
D. STUB-UP PENETRATIONS: REFER TO ELECTRICAL AND PLUMBING PLANS FOR
INDIVIDUAL STUB-UP LOCATIONS.
E. TOILET FLOOR PENETRATION: REFER TO CUT SHEETS FOR STUB-UP LOCATION
RELATIVE TO FINISHED WALL (IF APPLICABLE).
F. PENETRATION TO BE LOCATED ON CENTERLINE OF WALL OR AS REQUIRED
PER CONDITIONS.
G. TRENCHING OUTLINE FOR GUIDELINE USE ONLY. GENERAL CONTRACTOR TO
COORDINATE WITH SPECIFIC TRADES AND SITE CONDITIONS TO DETERMINE
ACTUAL LAYOUT.
H. REFER TO SHEET I104 FOR FLOOR FINISHES.
KEYNOTES
GENERAL NOTES
1 NEW FLOOR SINK -SEE DETAIL 5 / SHEET A102 (9)
2 DATUM CONTROL POINT.
3 NEW WATER CLOSET DRAIN.
4 DEMOLISH EXISTING FLOOR SINK. (9)
5 ELECTRICAL STUB-UP LOCATION. SEE ELECTRICAL SHEETS.
8 NEW MOP SINK DRAIN.
6 ROUTE NEW FILLING STATION DRAIN TO THE NEAREST FLOOR SINK.
REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION
7 ROUTE NEW 90LB ICE BIN DRAIN TO THE NEAREST FLOOR SINK.
REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION
9 NEW RESTROOM FLOOR DRAIN.
10 NEW WALL HYDRANT.
LEGEND
EXISTING WALL
DATUM POINT
FLOOR SINK
STUB-UP
DIMENSION
DATUM POINT
ALL CONDUIT
STUB-UPS TO
BE WITHIN THIS
BOUNDARY
1 3/4" POWER CONDUIT TO ELECTRICAL PANEL
2 1/2" PHONE TO MANAGER'S DESK
3 1/2" DATA CONDUIT TO MANAGER'S DESK
POS ELECTRICAL STUB-UP KEY
4 1/2" SECURITY TO MANAGER'S DESK
5 3/4" LAN CONDUIT TO POS/SAFE
6 3/4" POWER CONDUIT FOR PASTRY CASE
POS DIEWALL
EQ
EQ
3"
EQ EQ
1' - 6"
7"1 2 5 634
NOTE: SEE SHEET A102 - BUILDING FLOOR PENETRATION
PLAN FOR FINAL DIMENSIONED LOCATION.
2" CLR
(N) TRENCH(E) SLAB (E) SLAB
2
1
1
1 #4 EPOXY DOWEL A8 18" O.C. W/9" EMBEDMENT. DOWELS MAY
BE STAGGARD ON EACH SIDE OF TRENCG NOT TO EXCEED
18" O.C. ON EACH SIDE. USE SIMPSON SET-XP EPOXY
2 COUNTINIOUS #4 @ 18" O.C (1) #4 MIN. AT TRENCHES 24" OR
LESS IN WIDTH
31' - 5 3/4"
1'
-
6
"
6'
-
1
1
"
6' - 8 3/4"
15' - 11 3/4"
12' - 3 1/2"8' - 10 1/4"
22' - 11 3/4"
30' - 2 3/4"
1'
-
4
"
8'
-
2
"
2'
-
6
1
/
2
"
2
1
/
2
"
7'
-
8
"
1' - 6"
10
"
10"
1'
-
6
"
P X10726 (4)
P X10726
P X10726(3)
A102
4
1
1
1
1
1
2
2 5
4
4 4
4
4
4
4
4 4
8
6
2
A102
3
3
7 11
6' - 6"
7'
-
9
"
13
'
-
1
0
1
/
4
"
21' - 7"
EQ EQ
(2)
1
1
EQ
EQ
EQ
EQ
EQ EQ
9
9
P 10594
P 10594
FLOOR SINK HALF GRATE
FLUSH WITH FLOOR FINISH
GRAVEL BACKFILL
NO-HUB
CONNECTION
3" TAIL PIECE
CONC INFILL AND
TRENCH FOR
BELOW GRADE
UTILITIES
STAINLESS STEEL
FLOOR SINK
W/CLAMPING
FEATURE
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
3
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
A102
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
BUILDING FLOOR
PENETRATION PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
G.C. RESPONSIBLE TO VERIFY EXISTING SLAB
CONDITIONS PRIOR TO ANY SAWCUT OR TRENCH WORK.
ALL DIMENSIONS ARE TO FINISH FACE OF WALLS AND/OR
CENTER OF FLOOR SINK AND ELECTRICAL STUB-OUTS
G.C. TO X-RAY (E) FLOOR SLAB WHEN PROJECT IS NOT
SLAB ON GRADE.
G.C. TO COORDINATE ANY CONFLICT W/ STARBUCKS
C.M., ARCHITECT, AND ENGINEERS.
1 1/2" = 1'-0"4ELECTRICAL STUB-UPS AT POS 1 1/2" = 1'-0"3CONCRETE POUR BACK DETAIL
N
1/4" = 1'-0"1FLOOR PENETRATION PLAN
3" = 1'-0"2ECO-GRIP CLAMPING FLOOR SINK DETAIL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
T700
A401
2
NEW TO MATCH EXISTING
3' - 5 1/4"
EXISTING
15' - 3 1/4"
1 3/4"3' - 1 3/4"1 3/4"
3' - 1 3/4"1 3/4"
7'
-
1
"
EXISTING
18' - 8 1/2"
NEW TO MATCH EXISTING
3' - 3 1/2"
OMBREA -WINDOW FILM
MILKY CRYSTAL -
OPAQUE
WINDOW FILM
MILKY CRYSTAL -
OPAQUE WINDOW FILM
MILKY CRYSTAL -OPAQUE WINDOW FILM
2' - 10" VIF3 3/4" VIF
1/
2
"
M
A
X
.
2
1
1 EXPANSION JOINT
2 NEW THRESHOLD, MUST COMPLY
WITH DETAIL 7/G004
3 NEW STOREFRONT DOOR PANEL
PER MANUF. SPECS. KICK PLATE TO
COMPLY PER DETAIL 7/G004
4 INTERIOR FLOOR FINISH PER PLANS
2% MAX SLOPE
1
2
3
4
MI
N
10
"
2% MAX SLOPE
1 EXPANSION JOINT
2 STOREFRONT SILL. USE BLACK ANODIZED MULLIONS
3 GLAZING, MATCH EXISTING.
4 INTERIOR FLOOR FINISH PER PLANS
5 CONT. SEALANT AND BACKER ROD
1
2
3
4
5
1 EXISTING EXTERIOR FINISH TO REMAIN, GC TO VIF
2 PROVIDE 1X NAILER AS NEEDED
5 PROVIDE SEALANT AND BACKER ROD (CONT.)
1
2
3
4
5
5
4 5/8" GWB FINISHED PER SCHEDULES
6
3 STOREFRONT HEAD. USE BLACK ANODIZED MULLIONS
6 GLAZING, MATCH EXISTING.
7 PATCH AND REPAIR EXISTING VAPOR BARRIER.
7
7
1 EXISTING EXTERIOR FINISH TO REMAIN, GC TO VIF, PATCH AND
REPAIR PER NEW WORK
2 PROVIDE 1X NAILER AS NEEDED
4 5/8" GWB FINISHED PER SCHEDULES
5 PROVIDE SEALANT AND BACKER ROD (CONT.)
1
2
3
4 5
5
3 STOREFRONT JAMB. USE BLACK ANODIZED MULLIONS
6 GLAZING, MATCH EXISTING.
6
7 PATCH AND REPAIR EXISTING VAPOR BARRIER.
7 A401
10
4' - 5 1/2"
10
"
4'
-
3
1
/
2
"
3'
-
6
"
4' - 5 1/2"
20
A401
VI
F
1'
-
3
3
/
4
"
DASHED LINE INDICATES PREVIOUS
HEADER LOCATION -VIF -RELOCATE TO
ACCOMODATE FOR NEW DRIVE-THRU
WINDOW SIZE
2'
-
1
1
3
/
4
"
-
V
I
F
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
3
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
A401
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED PLANS &
ELEVATIONS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/2" = 1'-0"1ENLARGED NORTH STOREFRONT FLOOR PLAN
1/2" = 1'-0"2ENLARGED NORTH STOREFRONT ELEVATION
3" = 1'-0"19STOREFRONT THERSHOLD DETAIL
3" = 1'-0"18STOREFRONT SILL DETAIL
3" = 1'-0"20STOREFRONT HEAD DETAIL
3" = 1'-0"17STOREFRONT JAMB DETAIL 1/2" = 1'-0"9ENLARGED WEST DT WINDOW FLOOR PLAN
1/2" = 1'-0"10ENLARGED WEST DT WINDOW ELEVATION
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
VIF
EXISTING 6' - 10 1/2"
VIF
10"
NEW FILLER PANEL TO MATCH EXISTING
5 1/4"
NEW MULLION TO MATCH EXISTING
1 3/4"
6' - 0"
NEW MULLION TO MATCH EXISTING
1 3/4"
1 3/4"6' - 1 1/2"1 3/4"
NEW TO MATCH EXISTING
6' - 5"
EXISTING
3' - 3" VIF
7'
-
0
"
1
3
/
4
"
(5
"
M
A
X
)
3"
(3
5
"
M
I
N
)
3'
-
3
"
EQ
EQ
OMBREA -WINDOW FILM
MILKY CRYSTAL -OPAQUE WINDOW FILM
MILKY CRYSTAL -OPAQUE WINDOW FILM
NOTE: EXTERIOR BUILDING SIGNAGE
TO BE PERMITTED UNDER SEPARATE
REVIEW AND SUBMITTAL
EQ EQ
EQ EQ
S 13164
NEW STARBUCKS
SIREN LOGO
NEW LOCATION FOR
SUITE NUMBER -
CENTER ABOVE DOOR
A401A
2
D 10449 16
1 3/4"6' - 1 1/2"1 3/4"
EXISTING
3' - 4 1/2" VIF
NEW TO MATCH EXISTING
6' - 5"
EXISTING
3' - 3" VIF
10"6' - 10 1/2"
EQEQ
CLR.
2' - 6"
CLR.
6' - 0"
CL
R
.
5'
-
0
"
CL
R
.
4'
-
0
"
3' - 0"3' - 0"
D 23131 c
19
A401
18
A401A401
17
1 3/4"6' - 0"7"1 3/4"
5 1/4"1 3/4"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
3
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
A401A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED PLANS &
ELEVATIONS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/2" = 1'-0"2ENLARGED EAST STOREFRONT ELEVATION
1/2" = 1'-0"1ENLARGED EAST STOREFRONT FLOOR PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE
INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT,
GENERAL CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER
IMMEDIATELY.
B. GENERAL CONTRACTOR IS RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO
DEMOLITION TO REVEAL FULL SCOPE OF WORK. NOTIFY STARBUCKS
CONSTRUCTION MANAGER IF EXISTING CONDITIONS DEVIATE FROM
CONSTRUCTION DOCUMENTS.
C. REMOVE EXISTING INTERIOR WALL FINISH AS SHOWN. PATCH, REPAIR AND
PREP. SUBSTRATE TO RECEIVE NEW FINISH. REMOVE WALL COVERINGS ON
EXISTING WALLS TO REMAIN THAT FACE AREAS OF DEMOLITION. REMOVAL
SHALL INCLUDE ANY RESIDUAL MATERIAL AFTER DEMOLITION, (I.E. PIECES OF
WALL COVERING OR BACKING). REMOVAL OF ALL COVERINGS IS TO BE DONE
W/O DAMAGING THE EXISTING WALL SURFACE TO REMAIN. ALSO REMOVE WALL
DEVICES AND ITEMS MOUNTED TO WALLS.
D. REMOVE EXISTING FLOORING AS SHOWN. PATCH, REPAIR AND PREP.
SUBSTRATE TO RECEIVE NEW FINISH. REMOVAL OF EXISTING FLOORING
INCLUDES, BUT IS NOT LIMITED TO REMOVAL OF EXISTING CERAMIC TILE,
CARPET OR VINYL TILE FLOORING AND ASSOCIATED WALL BASE. SUBFLOOR TO
BE STRIPPED OF ALL COVERING/FINISH AND CLEANED TO REMOVE EXISTING
ADHESIVE, GROUT, MORTAR, DIRT AND COATINGS. FINAL SURFACE TO BE
STREAK-FREE WITH NO MACHINE MARKS AND/OR SMOOTH, STABLE AND LEVEL.
PROVIDE LEVELING WHERE NECESSARY TO ACCOMMODATE NEW FINISHES.
E. DEMOLITION PLANS REPRESENT APPROXIMATE LOCATION OF EXISTING WALLS
TO BE DEMOLISHED. FIELD VERIFY TYPE OF CONSTRUCTION AND HEIGHT OF
WALLS. PLANS DO NOT NECESSARILY INDICATE ALL DEMO WALLS, COUNTERS,
HANDRAILS, WALL PROTECTION, CLOSETS, SINKS ETC. PRIOR TO DEMOLITION,
FIELD VERIFY THAT WALLS TO BE REMOVED DO NOT PROVIDE SUPPORT FOR
EXISTING BUILDING ELEMENTS AND EXISTING CONSTRUCTION TO REMAIN.
NOTIFY STARBUCKS CONSTRUCTION MANAGER IF DEMOLITION WALLS SUPPORT
EXISTING BUILDING ELEMENTS.
F. DEMOLISH AND REMOVE DOORS, VINYL BASE, CONDUIT, WIRING, DUPLEXES,
DATA OUTLETS, CABLES, SHELVING, METAL STUD AND GYPSUM BOARD WALLS,
CLOSETS, CABINETS, FILES, COUNTERS, WOOD MOLDING, SHELVES AND
ENCLOSURES WHERE APPLICABLE.
G. VERIFY WITH STARBUCKS CONSTRUCTION MANAGER ACCESS TO THE
DEMOLITION AREA, INGRESS AND EGRESS ROUTES FOR MATERIAL AND
EQUIPMENT.
H. PROTECT EXISTING FLOORS, WALLS AND CORNERS TO REMAIN ALONG WORK
ACCESS ROUTES.
I. CONTAIN DUST AND DEBRIS WITHIN THE DEMOLITION AREA.
J. THE GENERAL CONTRACTOR SHALL PERFORM WORK IN A MANNER THAT DOES
NOT DAMAGE THE EXISTING STRUCTURE. DEMOLITION SHALL NOT
COMPROMISE THE STRUCTURAL INTEGRITY OF ANY WALLS, FLOORS, CEILINGS,
SUPPORTS, STRUCTURE, ETC. TO REMAIN.
K. ALL DEMOLITION MATERIALS AND DEBRIS SHALL BE DISPOSED OF ACCORDING
TO FEDERAL, STATE AND LOCAL REGULATIONS.
L. AT LOCATIONS WHERE EXISTING WALLS ARE TO BE REMOVED NEAR EXISTING
WALLS TO REMAIN, PERFORM DEMOLITION WITHOUT DISTURBING EXISTING
ELEMENTS TO REMAIN. WALLS TO REMAIN SHALL BE INTACT AND HAVE A NEAT
SURFACE.
M. REFER TO "ITEMS TO BE PRESERVED" LIST FOR ITEMS THAT SHALL BE
SALVAGED FOR RELOCATION. VERIFY WITH OWNER FOR ON SITE STORAGE
LOCATION OF SALVAGED ITEMS.
N. DAMAGED FIREPROOFING SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING.
O. THE GENERAL CONTRACTOR SHALL DEMOLISH ANY EXISTING ABANDONED
VOICE/DATA CABLING AND DEAD OR NON-USE ELECTRICAL BACK TO PANEL.
ALL RECEPTACLES NOT REUSED ARE TO BE REMOVED, PATCHED AND PAINTED.
P. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO
DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY THE
STARBUCKS CONSTRUCTION MANAGER PRIOR TO REMOVAL. SALVAGED
EQUIPMENT SHALL BE STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR
FUTURE INSTALLATION.
Q. LABEL ALL ITEMS AND PROPERLY STORE FOR RE-INSTALL.
R. REMOVE EXISTING PLUMBING FIXTURES AND HVAC EQUIPMENT AS NECESSARY.
CAP LINES AND TERMINATE DUCTS AS NECESSARY FOR THOSE NOT BEING RE-
USED.
KEYNOTES
GENERAL NOTES
14 DEMO EXISTING FRONTLINE AND BACKLINE -COUNTERTOPS AND
CABINETS. SALVAGE ALL COUNTERTOP EQUIPMENT AND 1DR
UNDERCOUNTER FRIDGES -U.N.O.
3 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT
OPERABLE.
19 DEMOLISH EXISTING RESTROOM AND ALL ASSOCIATED FIXTURES.
7 DEMOLISH EXISTING ARTWORK AND WALL FINISH AT CAFE AREA
6 DEMOLISH EXISTING NON-LOAD BEARING WALL
8 DEMOLISH EXISTING CONDIMENT CART
16 DEMOLISH EXISTING BACKBAR WALL TILE, MENUBOARDS, UPPER
CUBBIES, VALANCE AND TASK LIGHTING
9 DEMOLISH EXISTING MERCH BAY
15 DEMOLISH EXISTING FLOOR TILE AND BASE AT BACKBAR AND
WORKROOM AREAS
10 DEMOLISH EXISTING FLOOR TILE / BASE AT RETAIL AND SEATING
AREA
11 DEMOLISH EXISTING WALK-OFF MAT
12 DEMOLISH EXISTING INTERIOR FURNITURE THROUGHOUT
17 DEMOLISH EXISTING FLOOR SINK BELOW (9)
1 DEMOLISH EXISTING ENTRY/EXIT DOOR.
5 DEMOLISH EXISTING DRIVE-THRU WINDOW.
2 EXISTING EMPLOYEE EXIT DOOR TO REMAIN.
21 EXISTING ELECTRICAL PANEL TO REMAIN
22 RELOCATE EXISTING LOCKERS
20 DEMOLISH EXISTING RESTROOM DOOR.
KEYNOTES
13 DEMOLISH EXISTING WOOD CHAIR RAIL AT RETAIL AND SEATING
AREAS
18 DEMOLISH EXISTING BACKBAR TRAFFIC DOOR.
4 DEMOLISH EXISTING STOREFRONT.
23 RELOCATE EXISTING DIGITAL PRODUCTION MANAGER
24 RELOCATE EXISTING FIRE EXTINGUISHER
25 RELOCATE EXISTING XLERATOR HAND DRYER
26 RELOCATE EXISTING WATER FILLING STATION.
27 RELOCATE EXISTING FIRE ALARM PULL DEVICE.
28 RELOCATE EXISTING FIRE ALARM WARNING DEVICE.
29 RELOCATE EXISTING TEMPERATURE SENSOR.
30 RELOCATE EXISTING THERMOSTAT.
31 EXISTING GYP AND WINDOW FILM TO REMAIN.
32 DEMOLISH EXISTING BLACKOUT WINDOW FILM ONLY.
LEGEND
EXISTING ITEM TO REMAIN
ITEM TO BE DEMOLISHED
NON-LOAD BEARING WALLS TO BE DEMOLISHED
EXISTING ITEM TO BE RELOCATED
EXISTING ITEMS TO
PRESERVE AND RELOCATE
EXISTING ITEMS TO
PRESERVE IN-PLACE
A PASTRY CART
B BLENDERS (3)
C 1-DR U/C FRIDGE (6)
D WARMING U/C FRIDGE
E ESPRESSO MACHINES (2)
H CUP LABELER (4)
G GRINDER
F CUP CADDY (2)
AA TRASH BINS (3)
I NITRO TAP
J NITRO GENERATOR
X 1-DR REACH IN FREEZER
Y 2-DR REACH IN FREEZER
Z DATA RACK
K NITRO KEG DISPENSER
L WARMING OVENS (2)
M U/C THAW RACK
R R.O. SYSTEM & WATER HEATER
T SANITIZER
Q MANAGER'S EQUIPMENT
S METRO RACKS (10)
N DRIVE-THRU POS EQUIPMENT
O POS EQUIPMENT, PRINTER, & PHONE
P SAFE
U THAW RACK (2)
V 1-DR REACH IN FRIDGE (2)
W 2-DR REACH IN FRIDGE
A
B
BE E
D C C C
CCC
K
J
SS
S
S
S
S
S
S
S
S
AA
AA
AA
I
G
V
W
V
X
Q
N
L
P
O
Y
T
U
U
R
2
1
1
RETAIL
UNISEX
RR1
UNISEX
RR2
SEATING AREA
8
12
BACKBAR
107
3
3
3
6
6
6
6
6
6
6
6
6
6
6
6
6 6
171717
18
13
12107 13
161514
19
19
15
WORKROOM
21
20
20
22
22
17
17
17
17
17
17
H H H
M
Z
F F
23
5
9
11
DE
M
O
VI
F
.
KE
E
P
VI
F
.
4
3
KE
E
P
VI
F
.
DE
M
O
VI
F
.
KE
E
P
VI
F
.
DEMO
VIF.
KEEP
VIF.
24
25
25
26
27
28
H
30
29
31
32
32
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
2
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
D101
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
DEMOLITION FLOOR
PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
N
1/4" = 1'-0"1DEMOLITION PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
GENERAL NOTES
A. IF DURING DEMOLITION CONDITIONS ARE REVEALED THAT MAY JEOPARDIZE
INTEGRITY OF STRUCTURE OR PRECLUDE FOLLOWING DESIGN INTENT, GENERAL
CONTRACTOR TO NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY.
B. REMOVE EXTRANEOUS EQUIPMENT AS NECESSARY.
C. EXISTING SPRINKLERS TO REMAIN OPERATIONAL DURING CONSTRUCTION.
D. DEMOLISH AND REMOVE SUSPENDED ACOUSTIC LAY-IN, SPLINE OR GYPSUM/
PLASTER CEILING INCLUSIVE OF HANGERS AND CARRYING CHANNELS, WIRES,
CABLES, CONDUIT, ADHERED CEILING TILES, FLEX CONDUIT, ELECTRICAL BOXES,
SMOKE DETECTORS, LIGHT FIXTURES AND WIRING, DUCT WORK, PIPING AND
SUPPORT HANGERS. CUT HANGERS FLUSH. SPACES RECEIVING WALL DEMOLITION
WILL ALSO HAVE CEILING DEMOLITION UNLESS OTHERWISE NOTED.
E. REMOVAL OF LOW VOLTAGE EQUIPMENT, PERTAINING TO DATA/
COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED BY STARBUCKS
CONSTRUCTION MANAGER PRIOR TO REMOVAL. SALVAGED EQUIPMENT SHALL BE
STORED IN A CLIMATE CONTROLLED ENVIRONMENT FOR FUTURE INSTALLATION.
KEYNOTES
11 DASHED LINE INDICATES EXISTING BULKHEAD ABOVE TO BE
DEMOLISHED.
1 DEMOLISH EXISTING 2X2 ACT AT CAFE.
5 REMOVE ALL EXISTING LIGHTING, WIRING, CONTROLS AND
FASTENERS BACK TO ELECTRICAL PANEL
6 REMOVE EXISTING SECURITY CAMERAS, LOW VOLTAGE CABLING
AND ASSOCIATED CONDUITS. CAMERAS SHALL BE SALVAGED FOR
FUTURE REUSE
10 EXISTING HVAC RETURN DIFFUSER TO BE RELOCATED PER NEW
WORK. REFER TO MECHANICAL DRAWINGS FOR MORE
INFORMATION. (2)
12 DEMOLISH EXISTING UPPER CABINETRY AND ALL ASSOCIATED
LIGHTING & MENU BOARDS
13 RELOCATE EXISTING EXHAUST FAN DIFFUSER.
14 DEMOLISH EXISTING AIR CURTAIN ABOVE MAIN ENTRY/EXIT DOOR.
7 RELOCATE EXISTING EMERGENCY EXIT LIGHT/SIGN.
15 DEMOLISH EXISTING WALL MOUNTED SPEAKERS.
8 EXISTING EMERGENCY EXIT LIGHT/SIGN TO REMAIN IN PLACE.
16 RELOCATE EXISTING OCCUPANCY SENSORS. (4)
9 EXISTING HVAC SUPPLY DIFFUSER TO BE RELOCATED PER NEW
WORK. REFER TO MECHANICAL DRAWINGS FOR MORE
INFORMATION. (10)
17 RELOCATE EXISTING WATER HEATER/RO SYSTEM.
18 EXISTING EXTERIOR AWNING TO REMAIN. NIC
19 EXISTING ELECTRICAL PANELS TO REMAIN
20 RELOCATE EXISTING DATA RACK.
3 DEMOLISH EXISTING SOFFIT AT BACKBAR.
2 DEMOLISH EXISTING 2X4 ACT AT BACKBAR AND WORKROOM.
4 DEMOLISH EXISTING GYP CEILING AT RESTROOM.
21 RELOCATE EXISTING TEMPERATURE SENSOR.
LEGEND
EXISTING ITEM TO REMAIN
ITEM TO BE DEMOLISHED
NON-LOAD BEARING WALL TO BE DEMOLISHED
GWB CEILING TO BE DEMOLISHED
EXISTING ITEM TO BE RELOCATED
2X2 CEILING TO BE DEMOLISHED
2X4 ACT TO BE DEMOLISHED
RETAIL
UNISEX
RR1
UNISEX
RR2
SEATING AREA
5
BACKBAR
1
51
532
4
4
2
WORKROOM
6 12
5
5
5 6
11
7
7
8
10
10
9
9
9
9 9
9
9
99
9
13
13
14
18
18
18
18
18
19
20
16
16
16
16
17
15
15
21
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
2
8
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
D102
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
DEMO REFLECTED
CEILING PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
N
1/4" = 1'-0"1DEMOLITION REFLECTED CEILING PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
KEYNOTES GENERAL NOTES
1 ACCESSIBLE 30" X 48" CLEAR SPACE FOR WHEELCHAIR
2 EXISTING ELECTRICAL PANEL TO REMAIN
5 CLEAR SPACE AT ELECTRICAL PANELS.
6 INSTALL NEW INTERIOR FURNITURE THROUGHOUT AS SHOWN.
8 PARTNER RECOGNITION BOARD. SEE INTERIOR FINISH ELEVATIONS.
9 NEW TRASH & RECYCLING CART. SEE INTERIOR FINISH ELEVATIONS.
11 NEW MERCHANDISE DISPLAY
12 EXISTING SAFE LOCATED AT NEW POS CABINET. SEE ELECTRICAL
FOR ADDITIONAL INFORMATION.
13 HAND SINK W/ INTEGRAL SPLASH GUARD.
14 ACCESSIBLE 60" DIA. CLEAR SPACE FOR WHEELCHAIR
7 COMMUNITY BOARD. SEE INTERIOR FINISH ELEVATIONS.
4 RELOCATED EXISTING FIRE EXTINGUSHER -TYPE 2A10BC PER CFC
906
15 RELOCATED EXISTING METRO RACKS & NEW METRO RACKS. TOP
SHELF NOT TO EXCEED 5'-9" AFF.
16 NEW BUILT-IN BAQUETTE. SEE CASEWORK DETAILS FOR MORE
INFORMATION.
17 RELOCATED EXISTING WATER HEATER. MAKE: RHEEM, MODEL:
ES50-18-G-1, SOURCE OF POWER: ELECTRIC, KW/H: 18
18 DO NOT BLOCK FOOD CASE INTAKE/EXHAUST.
A. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM
UNLESS OTHERWISE NOTED.
B. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION
FOUNDATION STANDARDS OR EQUIVALENT.
C. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS,
EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR
ACCUMULATION OF DUST, DIRT AND DEBRIS.
D. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP
DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR
PREMIXING FAUCET.
E. SEE SHEET I601 FOR SCHEDULES.
F. SEE WALL FINISH PLAN FOR LOCATION, TAGGING AND FINISH SCHEDULES OF
APPLIED WALL TREATMENT.
G. NO VEGETABLE OR FOOD PREPARATION ON THE PREMISES.
H. NON-MOVABLE EQUIPMENT ON THE FLOOR SHALL BE MOUNTED ON 6" LEGS,
CASTERS OR MANUFACTURER SUPPLIED SKIDS.
I. ALL EQUIPMENT, CONSTRUCTION, AND INSTALLATION SHALL MEET ANSI
CERTIFICATION. ALL PLUMBING, GAS LINES AND CONDUITS, ETC., ARE TO BE
CONCEALED WHERE POSSIBLE. OTHERWISE, THEY MUST BE A MINIMUM OF
SIX INCHES OFF THE FLOOR AND NOT RUN ACROSS AISLE SPACE AND TO BE
INSTALLED AT LEAST 1/2" AWAY FROM THE WALL TO FACILITATE CLEANING.
ALL EQUIPMENT AND BACKSPLASHES ARE TO BE ADEQUATELY SEALED TO
THE WALL. DISPLAYS OF UNPACKAGED FOOD ARE TO BE PROTECTED WITH
SNEEZE GUARDS. ALL EXPOSED SURFACES OF SHELVING, CABINETS AND
UNDERCOUNTERS ARE TO BE SMOOTH AND SEALED.
J. G.C. TO CAULK WHERE COUNTERTOPS MEET FOOD CASE (SEAL WITH THE
DEPARTMENT OF ENVIRONMENTAL HEALTH APPROVED CAULKING) IF
APPLICABLE PER SCOPE.
K. CAULK AND SEAL ALL SEAMS BETWEEN SS COUNTERTOPS USING DOW
CORNING BRAND '732 MULTI PURPOSE SEALANT'.
L. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F.
M. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE
SEALED.
N. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS,
WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING.
O. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT
SHEET (E.G. ICE MACHINE).
P. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR
DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN.
Q. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM
THE LOCAL JURISDICTION.
19 VENDOR TO INSTALL WATER FILTRATION SYSTEM PER
MANUFACTURER'S REQUIREMENTS. G.C. TO PROVIDE PLUMBING
AND ELECTRICAL REQUIREMENTS.
3 NEW LUTRON LIGHTING CONTROL PANEL. SEE ELECTRICAL
DRAWINGS FOR MORE INFORMATION
10 NEW OPAQUE FILM -19459 MILKY CRYSTAL
20 MANAGERS DESK. SEE MANAGER'S DESK/EQUIPMENT RACK
ELECTRICAL DETAIL FOR ADDITIONAL INFORMATION.
21 PROVIDE POWER AND DATA FOR NEW WALL MOUNTED ORDER
STATUS BOARD, REFER TO ELECTRICAL DETAILS FOR MORE
INFORMATION.
22 PROVIDE POWER AND DATA FOR RELOCATED DIGITAL PRODUCTION
MANAGER.
23 PROVIDE POWER FOR NEW AUTOMATIC DOOR ACTUATOR, PUSH
PLATES, & HARDWARE KEY SWITCH. REFER TO DETAIL X/XXXX FOR
MORE INFORMATION.
24 SUGGESTED LOCATION FOR RELOCATED FIRE ALARM AND PULL
DEVICE. CONFIRM FINAL LOCATION WITH STARBUCKS
CONSTRUCTION MANAGER AND FIRE ALARM CONTRACTOR.
25 NEW DOOR CAUTION SIGN.
26 RELOCATED HVAC THERMOSTAT. COORDINATE WITH STARBUCKS
CONSTRUCTION MANAGER FOR FINAL LOCATION.
27 RELOCATED HVAC TEMPERATURE SENSORS. COORDINATE WITH
STARBUCKS CONSTRUCTION MANAGER FOR FINAL LOCATION.
28 8" HIGH SPLASH GUARDS AT EDGE OF 3-COMP SINK COUNTER.
29 NEW UNDER-SINK WALL HYDRANT @ 1' -6" AFF
A
I400
1
F 21359
F 21848
F 21449
F 21803
F 21453
(2)
(2)
E 23181
E 23337
E 10102
P 14688
E 10947 E 10977
P 13588
P 10995
P 10922
E 10698
E 22212
E 10416
E 10462
P 10116
E 11115
P 21352
F 10093
E 10862
P 22558
E 10859
E 10099
E 10172
P 13700
P 10447
P 10804
E 13578
E 10222
E 13676
F 21359
F 21979
F TK0076
F TK0077
FTK0078
F TK0053
F TK0079
E 10267
P 10549
P 10152
F 21788
F 21474
F 21359
P 22558
E 10862E10859
E 10099 E 10172
P 10116
P 21352E11115
F 10093
C 20131
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
E 23424
AA
AA
AA
U
U
V XVW
Y
S
S
S
S
S
S
S
S
S
S
T
R
Q
E 23181
E 10102
E 23337
1
1
1
1
1
1
1
2 3
4
5
6
11
7
8
9
.14
.
10
C 20390
12
13
13
13
14
15
16
17 19
18
20
21
10
E 23454
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
22
15
15
Z
(2)
1
F 23136 (2)
P 23355
24
D 23131 c
D 23129 b
D 23132 a
23
23
23
23
25
27
26
27
28
E 23423
(2)
D 23134 19
C 23009
CTK0065
1
1
P X0044
P X004429
29
15
A
A
A
34
"
M
A
X
.
2'
-
1
0
"
10" - 24" MAX
46
"
M
A
X
.
3'
-
5
"
EXISTING ITEMS TO
PRESERVE AND RELOCATE
EXISTING ITEMS TO
PRESERVE IN-PLACE
A PASTRY CART
B BLENDERS (3)
C 1-DR U/C FRIDGE (6)
D WARMING U/C FRIDGE
E ESPRESSO MACHINES (2)
H CUP LABELER (4)
G GRINDER
F CUP CADDY (2)
AA TRASH BINS (3)
I NITRO TAP
J NITRO GENERATOR
X 1-DR REACH IN FREEZER
Y 2-DR REACH IN FREEZER
Z DATA RACK
K NITRO KEG DISPENSER
L WARMING OVENS (2)
M U/C THAW RACK
R R.O. SYSTEM & WATER HEATER
T SANITIZER
Q MANAGER'S EQUIPMENT
S METRO RACKS (10)
N DRIVE-THRU POS EQUIPMENT
O POS EQUIPMENT, PRINTER, & PHONE
P SAFE
U THAW RACK (2)
V 1-DR REACH IN FRIDGE (2)
W 2-DR REACH IN FRIDGE
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
1
7
/
2
0
2
3
4
:
0
8
:
5
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I101
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
FF & E PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/4" = 1'-0"1FURNITURE, FIXTURES AND EQUIPMENT PLAN 1" = 1'-0"ACONDIMENT CART ACCESSIBILITY
N
Revision Schedule
Rev Date By Description
A 11/17/23 TH PRE-SCREENING COMMENTS
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY
IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING
SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL
DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS
PRODUCTION.
B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE
CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM
CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4)
WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF
DELIVERY.
C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY
CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE
NOTED.
D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND
INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE
PROPER INSTALLATION.
E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4"
(6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR.
F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND
TAGGING OF WALL TREATMENTS BY CV AND OTHERS.
G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT
LOCATIONS.
H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF
ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR.
I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR
ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION.
J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT
ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM
PERFORMANCE REQUIREMENTS.
K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK
VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS.
L. SEE SHEET I-601 FOR SCHEDULES.
M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS.
N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE
MECHANICALLY SECURED.
KEYNOTES
GENERAL NOTES
1 INSTALL CASEWORK, COUNTERTOPS, SHELVES, CUBBIES, FINISHES,
TRIM AND TABLE TOPS THROUGHOUT. REFERENCE FINISH
SCHEDULE AND MANUFACTURER'S SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
2 ALL COUNTERTOPS UTILIZED FOR CUSTOMER TRANSACTIONS,
INCLUDING BAR, CONDIMENT AND SALES COUNTERTOPS SHALL BE
INSTALLED AT 2'-10" (860 MM) MAXIMUM A.F.F.
3 VARIABLE WIDTH FILLER CABINET / COUNTERTOP REQUIRED TO
FILL GAP (FIELD VERIFY DIMENSION). VENDOR TO COORDINATE
EXACT DIMENSION WITH GC PRIOR TO INSTALLATION
4 DIMENSION CONTROL DATUM POINT
5 DASHED LINE INDICATES FINISHED HEADER ABOVE. SEE INTERIOR
ELEVATIONS.
6 ALL WOOD EXPOSED TO WET AREAS TO BE FINISHED AND SEALED
W/CLEAR SEALANT
INDICATES STAINLESS STEEL (SST) COUNTERTOP
LEGEND
INDICATES SOLID SURFACE (SS) COUNTERTOP
DATUM POINT
WAINSCOTT WOOD WALL CLADDING - WD0073
MAD200V @2' - 10" AFF + WOOD TRIM 1" X 1
1/2" - WD0073C X3030
RX10368
C X3030 WOOD TRIM 1" X 1 1/2" - WD0073 @ 9' - 1" AFF
(TOP OF TRIM)
C X3030 SOFFIT WOOD TRIM 1" X 1 1/2" - WD0073 @
11' - 1" AFF (TOP OF TRIM)
2' - 11 1/2"5' - 7"10 1/4"
1 1/4"11"1' - 11"8 1/2"11"11"1 1/4"
1 3/4"1 3/4"10 1/2"1' - 11 1/2"7 1/2"11 1/2"10 1/2"
I502
7
C 23413
C 23393
C 23391
C 23413
C 23385
C 23413
C 23393
C 23413
PL0027 PL0027
PL0027
PL0027
PL0027PL0027
PL0027
PL0027
C 23415
PL0027
2'
-
1
"
I401
1
I401A
1
I502A
19
I102
2
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
1 2 3 6
4
5
5
WD0073
C X3030
5
ADJACENT
TENANT (NIC)
I502B
1
C 23009
CTK0065
VERTICAL
WOOD TRIM
VERTICAL
WOOD TRIM
C X3040
C X3030
C X3030
SOFFIT WOOD
TRIM
1 6
I102
3
I502A
15
I502A
11
6
1
/
2
"
2' - 10 1/2"1' - 3"
PL0027
C X0017
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
4
2
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I102
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
CASEWORK PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
N
1/2" = 1'-0"2ENLARGED CBE UPPER CASEWORK DIMENSION PLAN
1/4" = 1'-0"1CASEWORK PLAN
N
1/2" = 1'-0"3ENLARGED DRIVE-THRU CABINET
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
KEYNOTES GENERAL NOTES
A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING
FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE.
B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT
COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE
USE.
C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR
SUPPORTS.
D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN
INTENT ONLY. REFER TO MECHANICAL DRAWINGS IF APPLICABLE PER SCOPE.
E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE
CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP.(IF
APPLICABLE)
F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS AND LIGHT TRIM RINGS TO MATCH
ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL THROUGHOUT RETAIL
PORTION OF STORE.
G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL
ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I601 & I602 FOR
SCHEDULES.
H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL
DRAWINGS.
I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER
TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602).
K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO
FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS.
M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE
PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING
DEMOLITION.
N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO
VERIFY NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT:
PHYLLIS MILLER (800) 442-4212.
O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO
BE ON A 24 HR LOCK-ON CIRCUIT.
P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT
LIGHTING IN SEATING AREA.
Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O.
R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN
CASEWORK.
S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS
U.N.O. EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK-
UP POWER SUPPLY.
T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF.
U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT
CORD PER THE NOTED A.F.F. HEIGHT.
V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF
RESTROOM WALL SCONCE.
W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN
GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO
STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO
INSTALLATION.
X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL
CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS
AFFECTED.
Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS.
Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED
IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'
CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION.
AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE.
BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT
OR PER LOCAL CODE REQUIREMENT.
9 EXISTING EMERGENCY EXIT LIGHT/SIGN TO REMAIN. MOUNT WITHIN
NEW CEILING AT SAME LOCATION PER NEW WORK.
8 RELOCATED EXISTING EMERGENCY EXIT LIGHT/SIGN.
1 NEW PAINTED GYPSUM BOARD SOFFIT AT BACKBAR AND CAFE.
7 NEW CAFE / BACKBAR / WORKROOM / RESTROOM / PARTNER REST /
MANAGER AREA LIGHTING.
10 RELOCATED EXISTING OCCUPANCY SENSORS. (4)
14 NEW HVAC DIFFUSER OMNI-AA AT BACKBAR AND CAFE AREAS, SEE
MECHANICAL DRAWINGS FOR MORE INFORMATION.
16 RELOCATED EXISTING SUPPLY HVAC DIFFUSER, SEE MECHANICAL
DRAWINGS FOR MORE INFORMATION. (10)
17 RELOCATED EXISTING RETURN HVAC DIFFUSER, SEE MECHANICAL
DRAWINGS FOR MORE INFORMATION. (2)
15 NEW 4FT TITUS HVAC DIFFUSER AT CAFE AREA, SEE MECHANICAL
DRAWINGS FOR MORE INFORMATION.
20 FURNISH AND INSTALL NEW DOOR ACTIVATED AIR CURTAIN PER
JURISDICTIONAL REQUIREMENTS. SEE MECHANICAL DRAWINGS
FOR ADDITIONAL INFORMATION.
24 DASHED LINE INDICATES LED STRIP BELOW. HOUSED WITHIN WOOD
SHELF REVEAL.
25 DASHED LINE INDICATES LED STRIP BELOW. HOUSED WITHIN
COUNTERTOP OVERHANG.
27 PLATFORM FOR HEATER AND WATER FILTRATION. PROVIDE SOFFIT
AND LIFT CEILING THIS AREA ONLY TO INSURE ADEQUATE
CLEARANCE FOR SERVICING.
3 NEW PAINTED GYPSUM BOARD SOFFIT AT SIREN SYSTEM.
2 NEW MOISTURE RESISTANT GYPSUM BOARD CEILING AT BACKBAR,
AND PARTNER REST & MANAGER AREAS. PAINT PER SCHEDULE.
4 NEW 2X4 ACT. CIRRUS: SECOND LOOK 511 AT CAFE.
5 NEW 2X4 WASHABLE ACT. AT WORKROOM AND BACKBAR.
6 NEW MOISTURE RESISTANT GYPSUM BOARD CEILING AT UNISEX
RESTROOMS. PAINT PER SCHEDULE.
18 RELOCATED EXISTING RESTROOM EXHAUST FAN.
21 NEW DT WINDOW WITH AIR CURTAIN WITHIN TRANSOM. PROVIDE
POWER PER ELECTRICAL DRAWINGS.
19 RELOCATED FIRE ALARM DEVICE -CONFIRM FINAL LOCATION WITH
STARBUCKS CONSTRUCTION MANAGE AND FIRE ALARM
CONTRACTOR.
11 PENDANT LIGHTS AT VARYING DROP LENGTHS. SEE INTERIOR
ELEVATIONS FOR DETAILS. (2)
12 PROVIDE POWER FOR DIGITAL MENU BOARDS PER DETAIL 1/I504.
REFER TO ELECTRICAL DRAWINGS FOR MORE INFORMATION.22 NEW LUTRON LIGHTING CONTROL PANEL. REFER TO ELECTRICAL
DRAWINGS FOR MORE INFORMATION.
13 DASHED LINE INDICATES PREVIOUS LOCATION OF SUPPLY/RETURN
HVAC DIFFUSER
23 PROVIDE NEW CEILING RECESSED SPEAKERS AT CAFE AND
PARTNER REST AREAS.
28 RELOCATED EXISTING DATA RACK.
26 DASHED LINE INDICATES LED STRIP BELOW. HOUSED WITHIN
SOFFIT OVERHANG.
29 RELOCATED HVAC TEMPERATURE SENSORS. COORDINATE WITH
STARBUCKS CONSTRUCTION MANAGER FOR FINAL LOCATION.
30 1" X 1 1/2" WOOD TRIM -WD0073 -SEE INTERIOR ELEVATIONS FOR
FINISH DETAILS
LEGEND
ELEVATION DATUM
STRIP LIGHTING
PENDANT LIGHT
ADJUSTABLE RECESSED CAN LIGHT - 1000LM - WALL WASH
EXIT SECURITY LIGHT
SUPPLY AIR
RETURN AIR
TROFFER
RECESSED MUSIC SYSTEM SPEAKER
RESTROOM WALL SCONCE
ADJUSTABLE RECESSED CAN LIGHT - 800LM - FLOOD
ADJUSTABLE RECESSED CAN LIGHT - 700LM - WF
L 20794
(6)
L 21783
L 20748 L 21774 (2)
(7)
L 21772 (2)L 21772 (4)
A 10015
L 21774 (2)
L 20748
L 21772 (12)
L 21772 (8)
L 21776 (3)
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
4
(N) GYP BD CEILING
AT 9' -0" AFF
(N) 2X4 ACT AT
10' -0" AFF
(N) 2X4 ACT CIRRUS
SECOND LOOK III
AT 13' -0" AFF
SW6071
(ES)
2
SW6071
(SG)
(N) GYP BD CEILING
AT 9' -0" AFF
(N) GYP BD CEILING
AT 9' -0" AFF
(N) GYP BD CEILING
AT 13' -0" AFF
(N) GYP BD CEILING
AT 13' -0" AFF
6
SW6071
(SG)
2
SW6071
(ES)2
SW6071
(ES)
6
SW6071
(SG)
(N) SOFFIT AT
11' -0" AFF
1
SW6071
(SG)
(N) SOFFIT AT
11' -0" AFF
1
SW6071
(SG)
5
7' - 6"
3
SW6071
(SG)
(N) SIREN SOFFIT
(PAINT FINISH)
7
7
7
777
7
7
7
8
9
10
10
10
11
A 22970
A 22972
(3)
12
13
13
13
13
13
13
13
13 13
13
13
14
14
14 14
14 14
15
16
1616
16
16
16
16
16
16
16
17 17
18
18
L 21772 (6)
A 10015 (4)
21
23 23
23
L 2221725
L 2221624
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
L 2225126
7' - 0"
27
9' - 10"
GYP. HEADER
(PAINT FINISH)
GYP. HEADER
(FRP FINISH)
7' - 0"
(N) HEADER
L 21776
(2)
28
L 21772 (10)
22
23
10
8
12' - 5"
RAISED ACT
CEILING
M X5050 20
15
19
1
I501A
Sim
L 21776 (2)
L 21774
29
C X3030
WD0073
C X3030
WD0073
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
4
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I103
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
REFLECTED CEILING
PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/4" = 1'-0"1REFLECTED CEILING PLAN
N
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
KEYNOTES GENERAL NOTES
A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING
FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE.
B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT
COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE
USE.
C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR
SUPPORTS.
D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN
INTENT ONLY. CONTACT PROJECT MANAGER IF CHANGED.
E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE
CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP.
F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS, RECESSED SPEAKERS AND LIGHT
TRIM RINGS TO MATCH ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL
THROUGHOUT RETAIL PORTION OF STORE.
G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL
ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I-601 & I-602
FOR SCHEDULES.
H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL
DRAWINGS.
I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER
TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602).
K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY
ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS.
M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE
PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING
DEMOLITION.
N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO VERIFY
NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT: PHYLLIS
MILLER (800) 442-4212.
O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO
BE ON A 24 HR LOCK-ON CIRCUIT.
P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT LIGHTING
IN SEATING AREA.
Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O.
R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN
CASEWORK.
S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS U.N.O.
EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK-UP
POWER SUPPLY.
T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF.
U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT
CORD PER THE NOTED A.F.F. HEIGHT.
V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF
RESTROOM WALL SCONCE.
W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN
GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO
STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO
INSTALLATION.
X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL
CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS
AFFECTED.
Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS.
Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED
IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'
CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION.
AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE.
BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT
OR PER LOCAL CODE REQUIREMENT.
1 DIMENSION CONTROL DATUM POINT
2 GC TO ISTALL RECESSED CAN LIGHTING AT CENTER OF TILE, U.N.O
LEGEND
ELEVATION DATUM
STRIP LIGHTING
PENDANT LIGHT
ADJUSTABLE RECESSED CAN LIGHT - 1000LM - WALL WASH
EXIT SECURITY LIGHT
SUPPLY AIR
RETURN AIR
TROFFER
RECESSED MUSIC SYSTEM SPEAKER
RESTROOM WALL SCONCE
ADJUSTABLE RECESSED CAN LIGHT - 800LM - FLOOD
ADJUSTABLE RECESSED CAN LIGHT - 700LM - WF
EQ 3' - 0"EQ
EQ
EQ
EQ
3'
-
6
"
EQ
EQ EQ
EQ
3'
-
6
"
EQ
EQ 5' - 0"EQ
EQ EQ
EQ
3'
-
0
"
EQ
2'
-
6
1
/
2
"
4'
-
0
3
/
4
"
7'
-
7
"
2'
-
2
1
/
2
"
3'
-
6
"
3'
-
6
"
3'
-
6
"
6' - 10 3/4"
10' - 9 1/2"
11' - 2 1/2"
2' - 0"3' - 6"3' - 6"3' - 6"3' - 0"2' - 10"
EQ 2' - 10"EQ
ADJACENT
TENANT (NIC)
18
'
-
5
3
/
4
"
5'
-
5
"
11' - 10 1/2"15' - 6"
2'
-
9
"
21
'
-
1
3
/
4
"
20
'
-
4
3
/
4
"
EQ EQ
EQ
EQ
3' - 9"10' - 3"5' - 10"
5'
-
7
"
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
2
1
1
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
4
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I103A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
REFLECTED CEILING
DIMENSION PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
N
1/4" = 1'-0"1REFLECTED CEILING DIMENSION PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
KEYNOTES
GENERAL NOTES
A. WHERE ACOUSTICAL CEILING MEETS WALL, PROVIDE ANGLE WALL MOLDING
FOR REVEAL. MATCH CEILING GRID COLOR WHEN APPLICABLE.
B. LEAVE (10) ADDITIONAL RETAIL CEILING TILES, TO MATCH RETAIL CEILING PAINT
COLOR, ABOVE THE WORKROOM CEILING AT MANAGER'S DESK FOR FUTURE
USE.
C. PROVIDE GROMMET AT ALL CEILING PENETRATIONS FOR FIXTURES OR
SUPPORTS.
D. HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SHOWN FOR DESIGN
INTENT ONLY. CONTACT PROJECT MANAGER IF CHANGED.
E. DIFFUSERS AND RETURNS AT BACKBAR IN ACOUSTICAL CEILING TILE TO BE
CENTERED IN TILE, PAINTED TO MATCH ADJACENT FINISHES - TYP.
F. PAINT ALL HVAC DUCTS, HVAC DIFFUSERS, RECESSED SPEAKERS AND LIGHT
TRIM RINGS TO MATCH ADJACENT CEILING OR SOFFIT PAINT COLOR - TYPICAL
THROUGHOUT RETAIL PORTION OF STORE.
G. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS' NATIONAL
ACCOUNT "COLOR CODE" WHEN ORDERING PAINTS. SEE SHEET I-601 & I-602
FOR SCHEDULES.
H. COORDINATE DUCT LOCATION AND DIFFUSER SIZE WITH MECHANICAL
DRAWINGS.
I. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
J. ALL PAINTED SURFACES TO RECEIVE MINIMUM ONE COAT OF PRIMER. REFER
TO PAINT SCHEDULE FOR SPECIFICATIONS (SHEET I-601 & I-602).
K. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
L. ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY
ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS.
M. FILL, PATCH, AND REPAIR AREAS OF GYP. BD. CEILING AT BACKBAR AND STORE
PERIMETER WHERE EXISTING LIGHTS HAVE BEEN REMOVED DURING
DEMOLITION.
N. ARMSTRONG CEILING TILES PER STARBUCKS SPECIFICATIONS. CALL TO VERIFY
NUMBERS. MATCH COLORS AS INDICATED ON PLAN. CONTACT: PHYLLIS
MILLER (800) 442-4212.
O. LIGHTING AT WORKROOM AND LIGHTS IDENTIFIED WITH "NL" (NIGHT LIGHT) TO
BE ON A 24 HR LOCK-ON CIRCUIT.
P. GENERAL CONTRACTOR SHALL PROVIDE DIMMER FOR INCANDESCENT LIGHTING
IN SEATING AREA.
Q. LIGHTING FIXTURES IN A.C.T. TO BE CENTERED IN CEILING TILE - U.N.O.
R. LIGHT FIXTURES TO BE LOCATED AT PRE-DETERMINED LOCATIONS IN
CASEWORK.
S. LOCATE EMERGENCY / EXIT LIGHTS ABOVE CENTERLINE DOOR OPENINGS U.N.O.
EMERGENCY LIGHTS TO BE PROVIDED WITH 90 MINUTE BATTERY BACK-UP
POWER SUPPLY.
T. ALL LIGHTS ABOVE BACKBAR AREA TO BE SHATTER PROOF.
U. GENERAL CONTRACTOR TO ADJUST THE LENGTH OF EACH PENDANT LIGHT
CORD PER THE NOTED A.F.F. HEIGHT.
V. REFER TO RESTROOM ELEVATIONS (SHEET I-411) FOR MOUNTING HEIGHT OF
RESTROOM WALL SCONCE.
W. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED IN
GYPSUM SOFFIT OVER FRONTBAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO
STARBUCKS'CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO
INSTALLATION.
X. GENERAL CONTRACTOR TO PROVIDE AND LOCATE SPRINKLERS PER LOCAL
CODES. CONTACT STARBUCKS CONSTRUCTION MANAGER IF DESIGN INTENT IS
AFFECTED.
Y. REFERENCE LOW VOLTAGE PLAN SHEET AND ELECTRICAL DRAWINGS.
Z. IF REQUIRED BY LOCAL CODE, GENERAL CONTRACTOR TO PROVIDE SEMI-
RECESSED SPRINKLER HEADS WITH POLISHED CHROME ESCUTCHEONS
CENTERED IN ACOUSTICAL CEILING TILE. IF PENDANT HEADS ARE REQUIRED
IN GWB SOFFIT OVER FRONT BAR, CONCEAL SUPPLY PIPING WITHIN SOFFIT.
GENERAL CONTRACTOR TO SUBMIT SPRINKLER LAYOUT TO STARBUCKS'
CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO INSTALLATION.
AA. DATA CABLING ABOVE HEAD SHALL BE IN PLENUM WHEN AVAILABLE.
BB. DATA CABLING AT EXPOSED CEILING SHALL BE INSTALLED IN METAL CONDUIT
OR PER LOCAL CODE REQUIREMENT.
1 DIMENSION CONTROL DATUM POINT
2 GC TO ISTALL RECESSED CAN LIGHTING AT CENTER OF TILE, U.N.O
3 ARTWORK LIGHTING TO BE CENTERED TO ARTWORK.
4' - 0"4' - 0"5' - 0"
3' - 5"4' - 10"4' - 7"
5'
-
3
1
/
2
"
5'
-
0
1
/
2
"
3'
-
6
"
3'
-
6
"
3'
-
6
"
5'
-
1
0
1
/
2
"
3'
-
6
"
3'
-
6
"
3'
-
6
"
1'
-
9
"
1'
-
9
"
1'
-
2
"
7'
-
1
"
5'
-
3
1
/
2
"
4'
-
1
"
3'
-
6
"
3'
-
6
"
3'
-
6
"
1' - 6"
4' - 10"
8' - 4"
4'
-
5
"
7
1
/
4
"
5'
-
5
"
8'
-
0
"
4' - 2 3/4"
EQ
EQ
2'
-
2
1
/
2
"
2' - 2 1/2"
2'
-
1
1
/
2
"
ADJACENT
TENANT (NIC)
1
CAFE
2
33 3
3
3
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
4
8
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I103B
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED SOFFIT
DIMENSION PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/2" = 1'-0"1ENLARGED SOFFIT REFLECTED CEILING DIMENSION PLAN
N
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
KEYNOTES
GENERAL NOTES
A. ALL TILE TO BE INSTALLED PER TILE COUNCIL OF AMERICA STANDARDS.
B. STARBUCKS TO SUPPLY FLOORING AND BASE FOR FRONT AND BACK OF
HOUSE AS NOTED IN SCHEDULES. GENERAL CONTRACTOR TO INSTALL.
GENERAL CONTRACTOR TO SUPPLY WORKROOM TILE AND BASE AND INSTALL.
GENERAL CONTRACTOR TO SUPPLY AND INSTALL MORTAR, ADHESIVE, AND
GROUT. GENERAL CONTRACTOR TO INSPECT ALL TILES AND REJECT
DAMAGED OR SUBSTANDARD TILES PRIOR TO
C. ALL FLOORING AND BASE MATERIAL TO BE INSTALLED ACCORDING TO
STARBUCKS SPECIFICATIONS.
D. ALIGN TILE TRANSITIONS ON WHOLE TILES WHEREVER POSSIBLE.
E. FOR WALK-OFF MAT / CARPET TILE INSTALLATION, REFER TO MANUFACTURER'S
INSTALLATION INSTRUCTIONS.
F. FOR ALL FLOOR AND BASE TILE INSTALLATIONS AT CASEWORK, MECHANICALLY
SAND AND SCARIFY WOOD SUBSTRATE TO COMPLETELY REMOVE ALL FINISH.
TROWEL ONE PRIMER COAT OF MAPEI TYP 1, KER 903 ADHESIVE AND ALLOW TO
AIR DRY.
G. TILE BASE AND THRESHOLD GROUT JOINTS TO ALIGN WITH TILE FLOOR GROUT
JOINTS.
H. REMOVAL OF EXCESS GROUT WILL BE DONE WITH WATER. THE USE OF
SULFURIC OR MURIATIC ACID IS PROHIBITED. IF THESE ACIDS ARE USED, THE
INSTALLER WILL BE REQUIRED TO REMOVE THE ACID AND RESTORE THE
GROUT AT THEIR EXPENSE.
I. PROVIDE GROUT JOINT OF 3/16" MAXIMUM DEVIATION OF TILE AND GROUT LINE
OF 1/4" PER 4'.
J. ADD OR REMOVE EXISTING TILE AND BASE AS REQUIRED BY SCOPE OF WORK.
K. EXISTING FLOORING AND WALL BASE TO REMAIN - U.N.O. REPLACE TILE
DAMAGED BY DEMOLITION OR CONSTRUCTION.
L. CORNERS AND EDGES OF TILE TO BE BULLNOSE. NO OUTSIDE GROUT
CORNERS OR RAW TILE EDGES ARE ALLOWED.
M. ALL WALLS AND CASEWORK OUTLINES / TOE KICK RECEIVE BASE AS NOTED.
N. REFER TO INTERIOR ELEVATIONS FOR BACKBAR WALL TILE LOCATION.
O. REFER TO SHEET I402 FOR RESTROOM WALL TILE LOCATION.
P. REFER TO SHEET I601 & I602 FOR SCHEDULES.
Q. FLOOR-WALL JUNCTURES AT BACKBAR WILL HAVE 3/8" RADIUS COVE, MINIMUM
4" HIGH.
R. WORKROOM TO BE FINISHED PER LOCAL CODE REQUIREMENTS.
S. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY CLEANABLE.
PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH-GLOSS FINISH
1 NEW FLOOR SINK. (9)
2 NEW CONCRETE CURB FOR FOOD CASE AND SAFE.
3 TILE START POINT WHERE INDICATED.
4 RECESSED WALK-OFF MAT AT ENTRY. SEE INTERIOR DETAIL
SHEETS FOR TRANSITION.
5 MOP SINK WHERE INDICATED. SEE PLUMBING PLANS FOR MORE
INFORMATION.
6 10" (150MM) CONCRETE CURB. TO BE FINISHED WITH POLYINYL
ECO-GRIP FLOORING.
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
1
T 19795
B X19795
T 20251 T 19289
T 20251
T 20251T20251T19795
T 19795
B X19795
B X19795 B 15116 B 15116
B 15116
B 15116
1
1
1
1
1
1
1
2
2
3
4
5
6
1
I503
2
I503
3
I503
5
I503
9
I503
11
I503
13
I503
14
I503
4' - 0"
6'
-
0
"
I503A
1
FLOOR FINISH LEGEND
T 20251
T 19795
T 19289
B 15116
POLYVINYLE ECOGRIP FLOORING @ WORKROOM,
PARTNER RESTROOM & BACKBAR
MANUFACTURER: ALLIED ECO-GRIP, INC.
COLOR: PEWTER
NEW WALK-OFF MAT @ STORE ENTRY
MANUFACTURER: IMPACT SPECIALITIES
TYPE / MODEL: HELIX Z2 & HELIX Z1
B X19795
POLYVINYL ECOGRIP FLOORING WRAPS UP 6" ON
WALLS AND CABINETS WITH 3/8" COVE RADIUS @
WORKROOM AND BACKBAR
MANUFACTURER: ALLIED ECO-GRIP, INC.
COLOR: PEWTER
T 19288
CAFE, CUSTOMER RESTROOM, PARTNER REST
AND MANAGER AREA FLOOR TILE
MANUFACTURER: STONEPEAK CERAMICS
TYPE / MODEL: ECOCRETE - HONED - 24" X 24"
COLOR: AQUA
CAFE, CUSTOMER RESTROOM, AND PARTNER
REST AND MANAGER AREA TILE BASE WITH 3/8"
COVE RADIUS
MANUFACTURER: STONEPEAK CERAMICS
TYPE / MODEL: ECOCRETE 6" X 12"
COLOR: AQUA
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
1/
3
/
2
0
2
4
8
:
4
2
:
5
9
P
M
C:
\
U
s
e
r
s
\
b
s
a
u
n
\
H
e
s
t
i
a
A
t
e
l
i
e
r
D
r
o
p
b
o
x
\
P
r
o
j
e
c
t
s
\
S
t
a
r
bu
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
-
10
0
0
5
.
r
v
t
I104
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
FLOOR FINISH PLAN
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
/
2
/
2
0
2
4
1/4" = 1'-0"1FLOOR FINISH PLAN
N
Revision Schedule
Rev Date By Description
B 1/2/24 MG City/County 1st round comments
B
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
KEYNOTES
GENERAL NOTES
A. GENERAL PAINT NOTES:
1. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS ACCOUNT
"COLOR CODE" WHEN ORDERING PAINTS.
2. TO LOCATE THE NEAREST SHERWIN WILLIAMS STORE, CALL (800) 321-8194.
ORDER PAINT BY STARBUCKS COFFEE COMPANY PROGRAM "COLOR
CODE". PAINT FORMULAS FOR "COLOR CODE" AVAILABLE AT (800)
321-8194. FURTHER INFORMATION AVAILABLE THROUGH ED STEIN AT (888)
731-7379.
3. SUBMIT TWO (2) SETS OF 8.5" X 11" BRUSH-OUTS OF ALL PAINT COLORS
AND FINISHES TO THE STARBUCKS CONSTRUCTION MANAGER FOR
APPROVAL PRIOR TO PAINTING.
4. REFER TO INTERIOR ELEVATIONS FOR COLOR LOCATIONS.
5. ALL WOOD AND METAL SURFACES SHALL BE PAINTED SEMI-GLOSS - U.N.O.
6. WALL RECEIVING VINYL MURAL WALLCOVERING SHALL BE SMOOTH AND
PVC PRIMED. MURALS TO BE SEALED. SEALER IS PROVIDED WITH MURAL.
B. PROVIDE AND INSTALL FULL-HEIGHT F.R.P. @ MOP SINK ENCLOSURE AND ALL
NEW WORKROOM WALLS.
C. PAINT COLOR TRANSITIONS ALLOWED AT CORNERS ONLY.
D. REFER TO INTERIOR ELEVATIONS FOR GRAPHICS LOCATIONS.
E. REFER TO CASEWORK FINISH SCHEDULE ON SHEET I601 FOR FURTHER
CASEWORK FINISH INFORMATION.
F. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
G. REFER TO INTERIOR ELEVATIONS AND REFLECTED CEILING PLAN FOR PAINT
CALL OUTS.
H. REFER TO SHEET I-601 FOR WALL TILE INFORMATION.
I. COORDINATE WINDOW SHADE LOCATIONS WITH STARBUCKS CONSTRUCTION
MANAGER.
J. G.C. TO APPLY F.R.P. TO ALL SIDES OF CABINET INTERIOR & WALLS UNDER
COUNTER.
K. INSTALL FRY REGLET CORNER TRIM PIECES AS NEEDED IN FRONT OF HOUSE
WHERE DRYWALL TO DRYWALL CORNERS EXIST WITH NO PROVIDED
WAINSCOT PROTECTION. ITEM IS G.C. PROVIDED DURING DRYWALL TAPING
PROCESS. TRIM PIECE CAN BE FIELD PAINTED. IF TO BE PAINTED, G.C. TO
REQUEST DMCT - 375 WITH CHEM FILM - A PAINTABLE SURFACE APPLIED BY
THE SUPPLIER AT NO ADDITIONAL COST.
L. REFER TO I402 FOR RESTROOM FINISH INFORMATION.
1 VERTICAL WOOD TRIM -WD0073 -REFER TO INTERIOR ELEVATIONS
2 INSTALL NEW FULL HEIGHT F.R.P. AT NEW WORKROOM WALLS.
3 PROVIDE PVC OUTSIDE CORNER GUARDS PER FRP
MANUFACTURER'S SPECIFICATIONS / INSTALLATION INSTRUCTIONS
AND / OR AS INDICATED ON PLAN.
4 INSTALL BACKBAR WALL TILE USING STACKED VERTICAL PATTERN
@ EXPOSED WALL SURFACE BETWEEN BASE OF SOFFIT AND TOP
OF BACKSPLASH AND BEHIND UNDERCOUNTER FRIDGES.
5 INSTALL NEW F.R.P. AT BACK BAR CABINETS BELOW COUNTERTOPS
AT HIDDEN AREAS.
6 WRAP TILE UP OVER HALF HEIGHT WALL
WALL FINISH LEGEND
NEW CERAMIC WALL TILE AT BACKBAR AND
PARTNER REST AREA
MANUFACTURER: STONEPEAK CERAMICS
TYPE / MODEL: COLOR STUDIO - 6" X 24"
COLOR: MALT
Q 20244
SW9169
INDICATES SHERMIN WILLIAMS SEMI-GLOSS
PAINT AT BACKBAR AND EGGSHELL PAINT AT
CAFE
COLOR: CHATURA GRAY
INDICATES ARTWORK PER SCHEDULE
G 16979
PARTIAL HEIGHT COMPOSITE WALLCLADDING -
CPX0066 - @ 7' - 0"
TYPE / MODEL: CORIAN
PATTERN COLOR: WILLOW
Q 11469
SW6071
INDICATES FRP FINISH AT WORKROOM
COLOR: WHITE
INDICATES SHERMIN WILLIAMS EGGSHELL
PAINT WITH WOOD TRIM - WD0073 AT CAFE
SOFFIT ABOVE
COLOR: POPULAR GRAY
NEW CERAMIC WALL TILE AT RESTROOM
MANUFACTURER: STONEPEAK CERAMICS
TYPE / MODEL: COLOR STUDIO - 6" X 24"
COLOR: WHITE
Q 20242
G 16991
G 16997
INDICATES ARTWORK PER SCHEDULEG 23229
NEW WALLCOVERING
MANUFACTURER: MOMENTUM TEXTILES INC
TYPE / MODEL: BURLAP
COLOR: RETREAT
Q 20623
WAINSCOTT WOOD WALL CLADDING - WD0073
MAD200V @2' - 10" AFF + WOOD TRIM 1" X 1
1/2" - WD0073C X3030
RX10368
C X3020
CPX066
I201 1
4
3
2
I202
2
3 1
4
I203
2
3 1
4
I204
6
7 5
8
I204
2
3 1
4
I402A
4
5 3
2
I402
6
7 5
4
I202 5
6
7
8
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
1
1
1
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
5
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I105
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
WALL FINISH PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/4" = 1'-0"1WALL FINISH PLAN
N
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
1 NEW TILE BASE.
2 NEW ARTWORK -REFER TO SCHEDULE "G" ON SHEET I601
3 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT
OPERABLE.
4 NEW MAIN ENTRY/EXIT DOOR.
5 NEW ACCESSIBLE AUTOMATIC DOOR ACTUATORS.
6 NEW AIR CURTAIN.
7 RELOCATED EXISTING EMERGENCY EXIT LIGHT/SIGN.
8 NEW WOOD PANELING -WD0073 MAD200V
9 NEW 1 1/2" X 1" WOOD TRIM -WD0073
10 NEW ROLLER SHADES.
11 NEW BANQUETTE SEATING
12 NEW MAGNETIC COMMUNITY BOARD W/1" BLACK METAL FRAME -
REFER TO SCHEDULE "G" ON SHEET I601
13 RELOCATED EXISTING OCCUPANCY SENSOR. VERIFY FINAL
LOCATION WITH STARBUCKS CONSTRUCTION MANAGER.
14 NEW ACCESSIBLE UNISEX RESTROOM SIGNAGE -SEE DETAIL 3/G004
15 NEW RESTROOM DOOR. FINISH PER SCHEDULE.
16 NEW OSB (ORDER-STATUS-BOARD).
17 RELOCATED EXISTING FIRE ALARM NOTIFICATION DEVICE. VERIFY
FINAL LOCATION WITH STARBUCKS CONTRUCTION MANAGER.
18 RELOCATED EXISTING HVAC TEMPERATURE SENSORS. VERIFY IN
FIELD. COORDINATE WITH STARBUCKS CONTRUCTION MANAGER
FOR FINAL LOCATION.
19 LED COVE LIGHT WITHIN COUNTERTOP OVERHANG
20 NEW 1 1/2" X 1 1/2" WOOD TRIM -WD0073
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
EQ 3' - 10"EQ
2'
-
7
"
1'
-
5
"
1"
2'
-
4
"
6"
13
'
-
0
"
2'
-
0
"
11
'
-
0
"
1'
-
0
"
1'
-
0
"
L 22251
GX12693
WD0073
Q 20623
B 15116
C X3030
C X3030
D 23132 a D 23129 b
D 23134 19
WD0073
WD0073
Q 20623
2'
-
9
1
/
2
"
1
C 23009CTK0065
WD0073 WD00731111
9
9
12
3
34
10
10
6
5
M X5050
7
WD0073
MAD200-V
RX10368 8
5
5 5
13
17
F 22488 TYP
G 23136
EQ 3' - 10"EQ EQ 3' - 10"EQ
2'
-
1
0
"
1"
1'
-
5
"
2'
-
7
1
/
4
"
B 15116
C X3030
RX10368
WD0073
MAD200-V
3' - 10"
12
'
-
6
"
6"
WD0073
SW6071
3'
-
9
1
/
4
"
3'
-
9
"
WD0073
C X3030
(ES)
WD0073
G 16991
WD0073
G 16997
WD0073
G 16979
Q 20623
A 22970
A 23021
Q 20244
SW9169
(ES)
2'
-
1
0
"
5"
1
2 2 2
8 9
9
16
CTK0065
WD007311 L 22217 19
11
'
-
0
"
1"
9'
-
0
"
1"
11
'
-
0
"
2'
-
0
"
6"
12
'
-
6
"
1'
-
0
"
1'
-
6
"
6"
1"
2'
-
4
"
6"
C X3030
3
1
/
4
"
B 15116RX10368
WD0073
MAD200-V
WD0073
SW9169
(ES)
1
7 1/4"9
WD0073
C X3030
8
9
R X10368
WD0073
MAD200-V
8
SW9169
(ES)
18
SW6071
(ES)
SW6071
(ES)
1"
CPX066
TYP
WD0073
C X303020
WD0073
C X30309
EQ 5' - 2"EQ
EQ
3'
-
1
1
"
EQ
11
'
-
0
"
6"
13
'
-
0
"
1"
2'
-
4
"
6"
SW9169
(ES)
RX10368
B 15116
C X3030
WD0073
G 23229
WD0073
C X3030
WD0073
SW9169
(ES)
B X19795
G 10427
G 10427
D 10190 15
WD0073
SW9169
(SG)
C X3030
WD0073
1
WD0073
MAD200-V9 81
14
14
15
13
2
9
9
C X3030
WD00739
1"
9'
-
0
"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
5
4
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I201
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
INTERIOR FINISH
ELEVATIONS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/8" = 1'-0"1CAFE ELEVATION A
3/8" = 1'-0"2CAFE ELEVATION B
3/8" = 1'-0"3CAFE ELEVATION C
3/8" = 1'-0"4CAFE ELEVATION D
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
1 NEW TILE BASE.
6 WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW UNDERSIDE
OF COUNTERTOP SUBSTRATE TO BE FRP.
16 WALL MOUNT HAND SINK WITH SOAP AND PAPER TOWEL
DISPENSER. G.C. TO PROVIDE BLOCKING FOR FASTENERS.
2 NEW TRAFFIC SWINGING DOOR. NO LATCH OR LOCK PROVIDED.
8 NEW 1 1/2" X 1" WOOD TRIM -WD0073
3 PROVIDE POWER FOR DIGITAL MENU BOARDS PER DETAIL 1/I504
7 PROVIDE 6" (150MM) MIN. INTEGRAL SPLASHGUARD AT HAND SINK
PER JURISDICTIONAL REQUIREMENTS.
11 LED COVE LIGHT WITHIN COUNTERTOP OVERHANG
15 RELOCATED DATA RACK
19 NEW MACHINE DIVERTER CONTROL PANEL.
4 PROVIDE POWER FOR PENDANT LIGHT.
5 NEW OSB (ORDER-STATUS-BOARD).
9 NEW SIREN ICE/CBE SOFFIT. G.C. TO PROVIDE WALL BLOCKING FOR
FASTENERS.
12 RELOCATED EXISTING OCCUPANCY SENSOR. VERIFY FINAL
LOCATION WITH STARBUCKS CONSTRUCTION MANAGER.
20 RELOCATED WATER HEATER/RO SYSTEM.
21 NEW BOOSTER PUMP
18 NEW MOP SINK
10 NEW SIREN CUP DISPENSERS
13 NEW DRIVE-THRU POS EQUIPMENT.
14 NEW DRIVE-THRU EQUIPMENT CABINET.
17 RELOCATED EXISTING HVAC TEMPERATURE SENSORS. VERIFY IN
FIELD. COORDINATE WITH STARBUCKS CONTRUCTION MANAGER
FOR FINAL LOCATION.
22 NEW 1 1/2" X 1 1/2" WOOD TRIM -WD0073
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
2'
-
1
0
"
7'
-
0
"
2'
-
0
"
11
'
-
0
"
2'
-
1
1
"
SW9169
(SG)12
C X3030
WD0073 8
B X19795 PL00271 (TYP)
(TYP)
Q 20244
A 23021
A 229705
L 22217
SW9169
(SG)
Q 11469
6
16
11
C X3030
WD007322
19
I503
20
I503
16
I503
7
6"
3'
-
9
1
/
4
"
3'
-
9
"
9'
-
0
"
1"
CPX066
C X3020
CPX066 9'
-
0
"
7'
-
0
"
8'
-
0
"
11
'
-
0
"
5"
2'
-
1
0
"
6"
CPX066
PL0027BX19795
L 20794
TYP
4
1
OPEN TO CAFE
TYP
4'
-
1
0
"
7'
-
6
"
6"
2'
-
1
"
1'
-
5
"
5"
2'
-
1
0
"
2'
-
0
"
7'
-
0
"
6"
11
'
-
0
"
1"
9'
-
0
"
11' - 0 1/4"2' - 3 1/2"
8
SW9169
Q 20244
(SG)
3 A 22970
A 22972
(3)
B X19795 PL0027
CPX066
(TYP)
(TYP)
6
WD0073
C X3030
15
I503716
1
2'
-
0
"
9'
-
0
"
9'
-
0
"
2'
-
0
"
4'
-
2
"
2'
-
1
0
"
11
'
-
0
"
1"
9'
-
0
"
1"
2'
-
4
"
6"
5"
C X3030
WD0073 SW9169
(ES)
D 10086 14
PL0027
2
910 SW9169
(SG)
CPX066
(SG)
14
13
66
B X19795PL0027
Q 20244
(TYP)
SW9169
(SG)
OPEN TO
WORKROOM
PL0027 8
1 PL0027
E 22627
SW9169 C X3020
CPX066
C X3020
TYP.
TYP.
CPX066
(TYP)
10
"
6"
PL
A
T
F
O
R
M
7'
-
1
1
/
4
"
5"
12
'
-
5
"
20
21
20
P 23355
B X19798 1
Q 11469
Q 11469
Q 11469
12
'
-
5
"
HE
A
D
E
R
9'
-
1
0
"
6"
Q 11469
OPEN TO
WORKROOM
6"
10
"
4'
-
1
0
3
/
4
"
5"
PL
A
T
F
O
R
M
7'
-
1
1
/
4
"
12
'
-
5
"
6"
10
'
-
0
"
HE
A
D
E
R
9'
-
1
0
"
19
Q 11469
Q 11469
B X197951
18
OPEN TO
WORKROOM
B X19795 1
3' - 6"
5"
7'
-
1
1
/
4
"
6"
10
"
12
'
-
5
"
6"
10
'
-
0
"
HE
A
D
E
R
9'
-
1
0
"
OPEN TO
WORKROOM
15
17
Q 11469
Q 11469
B X19795
Q 11469
Q 11469
1
3' - 6"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
5
:
5
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I202
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
INTERIOR FINISH
ELEVATIONS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/8" = 1'-0"2BACKBAR ELEVATION A
3/8" = 1'-0"1BACKBAR ELEVATION B
3/8" = 1'-0"3BACKBAR ELEVATION D
3/8" = 1'-0"4BACKBAR ELEVATION C
3/8" = 1'-0"6WORKROOM ELEVATION B
3/8" = 1'-0"8WORKROOM ELEVATION D
3/8" = 1'-0"5WORKROOM ELEVATION A
3/8" = 1'-0"7WORKROOM ELEVATION C
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
1 NEW TILE BASE.
7 WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW UNDERSIDE
OF COUNTERTOP SUBSTRATE TO BE FRP.
12 EXISTING EXIT DOOR TO REMAIN.
13 EXISTING EMERGENCY EXIT LIGHT/SIGN TO REMAIN
20 NEW ACCESSIBLE UNISEX RESTROOM SIGNAGE -SEE DETAIL 3/G004
19 RELOCATED SANITIZER PLACED ON COMMERCIAL CASTERS
4 NEW TRAFFIC SWINGING DOOR. NO LATCH OR LOCK PROVIDED.
17 PROVIDE 6" (150MM) MIN. INTEGRAL SPLASHGUARD AT SIDE END OF
3-COMP SINK
18 RELOCATED WATER FILLING STATION
11 NEW MANAGER CONTROL PANEL.
8 RELOCATED EXISTING OCCUPANCY SENSOR. VERIFY FINAL
LOCATION WITH STARBUCKS CONSTRUCTION MANAGER.
5 NEW PASTRY COOLING RACK
14 NEW DRIVE-THRU POS EQUIPMENT.
15 NEW DRIVE-THRU EQUIPMENT CABINET.
16 NEW DRIVE-THRU WINDOW
21 NEW RESTROOM DOOR. FINISH PER SCHEDULE
10 NEW ICE DIVERTER VALVE.
9 NEW ICE MACHINE.
6 NEW WARMING WALL
2 EXISTING ELECTRICAL PANELS TO REMAIN
3 NEW LUTRON LIGHTING CONTROL PANELS
22 RELOCATED EXISTING EMERGENCY EXIT LIGHT/SIGN.
23 RELOCATED FIRE EXTINGUISHER -TYPE 2A10BC PER CFC 906
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
10
'
-
0
"
HE
A
D
E
R
7'
-
0
"
3'
-
0
"
6"
2'
-
1
0
"
D 10086 14
PL0027
Q 11469
Q
Q 11469
Q 11469
B X19798BX19795 B X19795
4
9
10
11
22
1 1 123BX197951
9'
-
0
"
2'
-
1
0
"
2'
-
0
"
7'
-
0
"
10
'
-
0
"
6"
1'
-
6
"
SO
F
F
I
T
7'
-
6
"
B X19795
Q 11469
Q 11469
SW9169 SW9169
OPEN TO
BACKBAR
8
B X19795
8
OPEN TO
WORKROOM
6
1
1
5
7
18
17
19 CPX066
5"
2'
-
1
0
"
(SG)(SG)
7'
-
9
1
/
2
"
9'
-
0
"
10
'
-
0
"
3'
-
6
"
5"
2'
-
1
0
"
B X19795
SW9169
16
(SG)
13
12
2
3
WALL NOT PERPENDICULAR
TO CURRENT VIEW
14 15
7
B X19795
6"
Q 11469Q11469
Q 11469
11
(SG)CPX066
C X3020
CPX066
C X3020
7'
-
0
"
10
'
-
0
"
6"
7'
-
1
"
OPEN TO
MANAGER
AREA
OPEN TO
PARTNER
REST AREA
D 10190 05
G 10427
G 10427
Q 11469 Q 11469 Q 11469Q11469
WALL NOT PERPENDICULAR
TO CURRENT VIEW
WD0073
20
20
21
B X197951 B X197951 B X197951
2
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
0
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I203
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
INTERIOR FINISH
ELEVATIONS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/8" = 1'-0"2BACKBAR/WORKROOM ELEVATION B
3/8" = 1'-0"1BACKBAR/WORKROOM ELEVATION A
3/8" = 1'-0"3BACKBAR/WORKROOM ELEVATION C
3/8" = 1'-0"4BACKBAR/WORKROOM ELEVATION D
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. FOR GRAPHICS SCHEDULE, REFER TO THE FURNITURE, FIXTURES, AND
EQUIPMENT (FF & E) SCHEDULES ON SHEET I601.
B. REFER TO MANUFACTURER'S INSTRUCTIONS INCLUDED WITH
ARTWORK/GRAPHICS FOR PROPER INSTALLATION.
C. CHANGE PAINT COLOR ONLY AT INSIDE CORNERS UNLESS OTHERWISE
INDICATED.
D. PAINT FINISHES SHALL BE APPLIED AS FOLLOWS, UNLESS NOTED OTHERWISE:
1) WOODS AND METAL SURFACES SHALL BE
SEMI-GLOSS OR EQUAL.
2) ACCENT AND TRIM PAINTS TO BE SEMI-GLOSS OR EQUAL.
a. WALL AND CEILING PAINTS TO BE EGGSHELL OR EQUAL.
3) PAINTS IN BOH, RESTROOM(S) OR CAFE BAR SHALL BE SEMI-GLOSS OR
EQUAL.
E. PAINT SUBSTITUTIONS ARE NOT ALLOWED. USE STARBUCKS NATIONAL
ACCOUNT COLOR CODE WHEN ORDERING PAINTS.
F. FLOORS, WALLS AND CEILING FINISHES IN FOOD PREPARATION AREAS SHALL
BE SMOOTH, NON-TOXIC, NON-ABSORBENT, DURABLE AND EASILY
CLEANABLE. PAINT SHALL BE WASHABLE; SEMI-GLOSS OR HIGH GLOSS FINISH.
G. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETRY) SHALL BE
SEALED.
H. REFER TO CASEWORK FINISH SCHEDULE ON THE CASEWORK FINISH PLAN ON
SHEET I102 FOR CASEWORK FINISH MATERIAL INFORMATION.
I. ALIGN TILE TRANSITIONS ON WHOLE TILES AS SHOWN.
J. ALL FLOOR AND WALL JUNCTIONS IN STORAGE AND FOOD PREPARATION
AREAS SHALL HAVE A 6" COVED BASE.
K. ALL FOOD STORAGE SHALL BE 6" (150MM) A.F.F.
L. INSTALL BLOCKING AND HANGERS FOR WALL SHELVING BEFORE INSTALLING
BACK BAR TILE.
M. GENERAL CONTRACTOR TO PROVIDE AND INSTALL WORKROOM WALL
FINISHES.
N. INSTALL WALL CABINETS BEFORE BACKBAR WALL TILE - RUN BACKBAR WALL
TILE TO UNDERSIDE OF WALL CABINETS - NOT BEHIND CABINETS.
O. PATCH AND REPAIR ANY DAMAGE TO EXISTING GYP. BD. PRIOR TO PAINTING.
P. ALL PAINTED SURFACES TO RECEIVE A MINIMUM ONE COAT OF PRIMER. SEE
PAINT SCHEDULE FOR SPECIFICATIONS.
Q. PAINT SHALL NOT BE APPLIED OVER EXISTING MURALS OR VINYL
WALLCOVERING.
R. ALL PAINT DESIGNATIONS TO EXTEND AROUND OUTSIDE CORNERS - U.N.O.
S. SEE I402 ENLARGED RESTROOM PLAN DETAILS FOR ACCESSORY MOUNTING
HEIGHTS.
T. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY PROJECT
ARCHITECT AND STARBUCKS CONSTRUCTION MANAGER OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION.
U. CASEWORK, COUNTERTOPS AND WALL MOUNTED FURNISHINGS TO BE
ATTACHED TO SUPPORTING MEMBERS PER PRODUCT MANUFACTURER'S
SPECIFICATIONS.
V. TILE BASE - REFER TO I104 FOR DESIGN ID TAG AND DETAILS.
KEYNOTES
GENERAL NOTES
7 EXISTING STOREFRONT TO REMAIN. WINDOWS ARE FIXED AND NOT
OPERABLE.
10 NEW SEMI-TRANSPARENT WINDOW FILM -X1999 OMBREA. SEE
WINDOW SCHEDULE FOR FINISH DETAILS.
9 WALL FINISH BEHIND EXPOSED CABINETRY AND BELOW UNDERSIDE
OF COUNTERTOP SUBSTRATE TO BE FRP.
5 NEW 1 1/2" X 1" WOOD TRIM -WD0073
8 LED COVE LIGHT WITHIN SHELF REVEAL
6 NEW STOREFRONT. WINDOWS ARE FIXED AND NOT OPERABLE.
2 NEW PARTNER RECOGNITION BOARD -REFER TO SCHEDULE "G" ON
SHEET I601
4 NEW 1 1/2" X 1 1/2" WOOD TRIM -WD0073
1 NEW TILE BASE.
11 RELOCATED EXISTING HVAC THERMOSTAT. VERIFY IN FIELD.
COORDINATE WITH STARBUCKS CONTRUCTION MANAGER FOR
FINAL LOCATION.
12 PROVIDE OUTLET FOR MICROWAVE.
13 PROVIDE (2) CONVENIENCE OUTLET FOR PARTNER USE W/ USB-A /
USB-C PORTS
3 NEW WOOD PANELING -WD0073 MAD200V
14 RELOCATED LOCKERS WALL MOUNTED @ 6" AFF (2)
15 NEW OPAQUE WINDOW FILM -19459 MILKY CRYSTAL. SEE WINDOW
SCHEDULE FOR FINISH DETAILS.
INDICATES WALL BLOCKING. BLOCKING TO BE
PROVIDED AS REQUIRED TO SUPPORT WALL
ATTACHMENTS. EXTEND BLOCKING 4" (100mm)
BEYOND EDGE OF ATTACHMENTS.
LEGEND
WALL TILE START POINT DATUM
6"
13
'
-
0
"
B 15116
(ES)
14
SW9169
1
7
7 6
10 Z X1999
13
'
-
0
"
6"
2'
-
4
"
1"
OPEN TO
WORKOOM
R X10368 B 15116
C X3030
C X3040
WD0073
MAD200-V
1 4 WD0073
WD00735
3
(ES)
SW9169
EQ3' - 9"EQ
1'
-
1
1
"
3' - 8"
4
1
/
2
"
3'
-
1
0
1
/
2
"
1'
-
1
0
"
WD0073
G X0013
6"
13
'
-
0
"
2'
-
1
1
/
4
"
2'
-
1
0
"
11
1
/
4
"
1
1
/
2
"
4'
-
1
1
1
/
4
"
6'
-
0
"
1
1
/
2
"
11
1
/
4
"
(ES)
12
SW9169
13
9
WD0073
C X3030 54CX3040
WD0073
PL0027B151161
6"
13
'
-
0
"
B 15116
SW9169
(ES)
1
14
8L22216
Z X1999
10
6"
13
'
-
0
"
(ES)
11
B 151161
SW9169
13
'
-
0
"
6"
(ES)
1
OPEN TO
WORKOOM
B 15116
SW9169
6"
13
'
-
0
"
(ES)
1 B 15116
SW9169
6"
13
'
-
0
"
(ES)
15
Z 19459
SW9169
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
0
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I204
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
INTERIOR FINISH
ELEVATIONS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/8" = 1'-0"1EMPLOYEE REST AREA ELEVATION A
3/8" = 1'-0"2EMPLOYEE REST AREA ELEVATION B
3/8" = 1'-0"3EMPLOYEE REST AREA ELEVATION C
3/8" = 1'-0"4EMPLOYEE REST AREA ELEVATION D
3/8" = 1'-0"5MANAGER AREA ELEVATION A
3/8" = 1'-0"6MANAGER AREA ELEVATION B
3/8" = 1'-0"7MANAGER AREA ELEVATION C
3/8" = 1'-0"8MANAGER AREA ELEVATION D
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
KEYNOTES
GENERAL NOTES
A. GENERAL CONTRACTOR TO SCHEDULE WITH LOCAL REFRIGERATION
CONTRACTOR TO CONDUCT INITIAL FOOD CASE START-UP AND TESTING.
FOR APPROVED CONTRACTOR, CONTACT VENDOR.
B. THE SITE IS SERVED BY THE MUNICIPAL WATER AND SEWER SYSTEM
UNLESS OTHERWISE NOTED.
C. ALL EQUIPMENT AND INSTALLATION WILL MEET NATIONAL SANITATION
FOUNDATION STANDARDS OR EQUIVALENT.
D. EQUIPMENT UNITS SHALL CONTAIN NO EXPOSED THREADS,
EMBELLISHMENTS OR OVERHANGING EDGES THAT SERVE AS PLACES FOR
ACCUMULATION OF DUST, DIRT AND DEBRIS.
E. WARMING OVEN(S) SHOWN FOR PERMITTING PURPOSES. INSTALLATION AT
STORE OPENING TO BE VERIFIED BY STARBUCKS CONSTRUCTION
REPRESENTATIVE.
F. EACH HAND WASHING SINK WILL HAVE A SINGLE SERVICE TOWEL AND SOAP
DISPENSER, AND ALL HAND SINKS TO HAVE A COMBINATION FAUCET OR
PREMIXING FAUCET.
G. SEE SHEET I601 FOR SCHEDULES.
H. G.C. TO CONFIRM CASEWORK DELIVERY DATE WITH CONSTRUCTION
MANAGER PROVIDING A MINIMUM SCHEDULING NOTICE OF 4 WEEKS AND 1
WEEK PRIOR TO SCHEDULED DATE OF DELIVERY.
I. SEE WALL FINISH PLAN FOR LOCATION, TAGGING AND FINISH SCHEDULES OF
APPLIED WALL TREATMENT.
J. EDIBLE PRODUCTS TO BE PHYSICALLY SEPARATED FROM STORAGE OF NON-
EDIBLE OR TOXIC PRODUCTS.
K. NO VEGETABLE OR FOOD PREPARATION ON THE PREMISES.
L. NO ALCOHOLIC BEVERAGES TO BE SOLD OR CONSUMED ON THE PREMISES.
M. THE MAXIMUM NUMBER OF EMPLOYEES PER SHIFT SHALL NOT EXCEED 4.
N. NON-MOVABLE EQUIPMENT ON THE FLOOR SHALL BE MOUNTED ON 6" LEGS,
CASTERS OR MANUFACTURER SUPPLIED SKIDS.
O. ALL EQUIPMENT, CONSTRUCTION, AND INSTALLATION SHALL MEET ANSI
CERTIFICATION. ALL PLUMBING, GAS LINES AND CONDUITS, ETC., ARE TO BE
CONCEALED WHERE POSSIBLE. OTHERWISE, THEY MUST BE A MINIMUM OF
SIX INCHES OFF THE FLOOR AND NOT RUN ACROSS AISLE SPACE AND TO BE
INSTALLED AT LEAST 1/2" AWAY FROM THE WALL TO FACILITATE CLEANING.
ALL EQUIPMENT AND BACKSPLASHES ARE TO BE ADEQUATELY SEALED TO
THE WALL. DISPLAYS OF UNPACKAGED FOOD ARE TO BE PROTECTED WITH
SNEEZE GUARDS. ALL EXPOSED SURFACES OF SHELVING, CABINETS AND
UNDERCOUNTERS ARE TO BE SMOOTH AND SEALED.
P. G.C. TO CAULK WHERE COUNTERTOPS MEET FOOD CASE (SEAL WITH THE
DEPARTMENT OF ENVIRONMENTAL HEALTH APPROVED CAULKING).
Q. NON-MOVABLE EQUIPMENT ON THE COUNTER SHALL BE MOUNTED ON 4"
LEGS.
R. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK
VENDOR FOR COMPLETE INSTALLATION INSTRUCTION.
S. FOR ALL NEW CASEWORK ITEMS BASE UNITS SHALL BE SET ON 1/4" NON-
ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR.
T. CAULK AND SEAL ALL SEAMS BETWEEN SS COUNTERTOPS USING DOW
CORNING BRAND '732 MULTI PURPOSE SEALANT'.
U. STAINLESS STEEL TOP AT CBS STATION TO BE INSTALLED BY G.C.
V. G.C. TO PROVIDE AND INSTALL ANGLE AT OUTSIDE CORNERS TYP. AND
ALONG BOTTOM EDGE OF CASEWORK PANELS.
W. ALL FOOD STORAGE SHALL BE 6" (150mm) A.F.F.
X. ALL WOOD SURFACES (DOORS, TRIM, SHELVES, CABINETS) SHALL BE
SEALED.
Y. ALL EQUIPMENT AND CABINETRY WILL BE FLUSH MOUNTED TO COUNTERS,
WALLS OR FLOORS, OR BE RAISED TO ALLOW FOR CLEANING.
Z. CONFIRM ALL NECESSARY EQUIPMENT CLEARANCES PER PRODUCT CUT
SHEET (E.G. ICE MACHINE).
AA. FOR LOCATION OF COUNTERTOP EQUIPMENT, REFER TO CASEWORK
ELECTRICAL DETAILS.
BB. FOR PLUMBING FIXTURES, REFER TO THE PLUMBING DESIGN PLAN. FOR
DATA DEVICE SCHEDULE, REFER TO THE ELECTRICAL DESIGN PLAN.
CC. PROVIDE FIRE EXTINGUISHERS AS NOTED ON THE APPROVED PLANS FROM
THE LOCAL JURISDICTION.
1 8" HIGH INTEGRAL SST SPLASH GUARD ON BOTH SIDES. EXTENDED
FULL DEPTH OF THE SINK.
2 NEW NITRO BADGE KIT
EXISTING ITEMS TO
PRESERVE AND RELOCATE
EXISTING ITEMS TO
PRESERVE IN-PLACE
A PASTRY CART
B BLENDERS (3)
C 1-DR U/C FRIDGE (6)
D WARMING U/C FRIDGE
E ESPRESSO MACHINES (2)
H CUP LABELER (4)
G GRINDER
F CUP CADDY (2)
AA TRASH BINS (3)
I NITRO TAP
J NITRO GENERATOR
X 1-DR REACH IN FREEZER
Y 2-DR REACH IN FREEZER
Z DATA RACK
K NITRO KEG DISPENSER
L WARMING OVENS (2)
M U/C THAW RACK
R R.O. SYSTEM & WATER HEATER
T SANITIZER
Q MANAGER'S EQUIPMENT
S METRO RACKS (10)
N DRIVE-THRU POS EQUIPMENT
O POS EQUIPMENT, PRINTER, & PHONE
P SAFE
U THAW RACK (2)
V 1-DR REACH IN FRIDGE (2)
W 2-DR REACH IN FRIDGE
E 10267
E 23442
E 23444
E 23420
P 17565
E 17564
P 10153
P 10215
P 10597
E 22885
P 10549
P 10152
E 16239
P 22768
E 19278E19278 P 10153
P 22642
P 11003
P 22768
P 10153
P 22642
P 11003
P 22768
P 10153
P 22642
P 11003
E 12618
E 23445
E 23445
P 10597
A
BB
K
J
I
E E
C C C
E 19742
C
C
L
L
E 23419
E 23421
E 23419
E 11115
E 10992
1
1
E 11115
E 10992
C
P
O
N
H
E 13330
E 10855
E 10396
E 10858
E 10091
E 10791
E 13584
(2)(2)
(2)
H (2)
F F
G
M
E 23380
E 23381
E 23422
H
(2)
(2)
A 20294
(2)
D
E 22627 2
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
0
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I400
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED ENGINE
PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/2" = 1'-0"1ENLARGED FF&E PLAN
N
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY
IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING
SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL
DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS
PRODUCTION.
B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE
CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM
CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4)
WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF
DELIVERY.
C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY
CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE
NOTED.
D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND
INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE
PROPER INSTALLATION.
E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4"
(6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR.
F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND
TAGGING OF WALL TREATMENTS BY CV AND OTHERS.
G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT
LOCATIONS.
H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF
ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR.
I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR
ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION.
J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT
ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM
PERFORMANCE REQUIREMENTS.
K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK
VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS.
L. SEE SHEET I-601 FOR SCHEDULES.
M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS.
N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE
MECHANICALLY SECURED.
GENERAL NOTES
10
3
/
4
"
1'
-
3
"
2'
-
6
"
1'
-
3
"
1'
-
3
"
2'
-
6
"
1'
-
3
"
1
1
/
2
"
2'
-
4
3
/
4
"
3"1' - 3"1' - 3"1' - 3"1' - 6"1' - 3"4' - 7 1/4"3"
3'
-
1
1
/
2
"
1'
-
3
"
1'
-
3
"
1'
-
3
"
2'
-
6
"
1'
-
1
1
"
1'
-
1
0
"
4'
-
6
1
/
4
"
2
1
/
2
"
2' - 11 1/4"
2' - 8 3/4"
1' - 3"1' - 3"1' - 3"1' - 3"1' - 3"1' - 3"3' - 9"2 3/4"1' - 8"5' - 0 1/2"1' - 8"
5 1/2"
1' - 8"1' - 3"2' - 5"
1"
1' - 3"1' - 0"
2' - 6"1' - 3"2' - 6"3"
1'
-
3
"
8'
-
9
1
/
2
"
1/
4
"
2'
-
6
"
1/
4
"
1'
-
3
"
C 20633
C 17745C17747C17741C17741C17741
C 17573
C 17574
C 19281 C 19281 C 19281
C 17574 C 11142 C 17747 C 21189
C 21189
C 21190
C 21191
C 21946
C 17744
C 18860
C 18859
C 18865
C 18717
C 18887
C 18873
C 18888
C 18887
C 17745
C 17740
C 17745
C 17740
C 17574C17741C23388C17741C17747C17741C17573 C 17573
C 20633
C 17747
C 17747
C 23426
C 17747C17743 C 18887
C 17896
C 17894
C 11155
C 19343
2'
-
4
3
/
4
"
2'
-
4
3
/
4
"
2' - 4 3/4"
2' - 4 3/4"
2' - 4 3/4"
1
I502
3
I502
I502
13
(2)
2'
-
6
"
5'
-
3
"
3'
-
6
1
/
2
"
BACKBAR
INDICATES STAINLESS STEEL (SST) COUNTERTOP
LEGEND
INDICATES SOLID SURFACE (SS) COUNTERTOP
DATUM POINT
WAINSCOTT WOOD WALL CLADDING - WD0073
MAD200V @2' - 10" AFF + WOOD TRIM 1" X 1
1/2" - WD0073C X3030
RX10368
C X3030 WOOD TRIM 1" X 1 1/2" - WD0073 @ 9' - 1" AFF
(TOP OF TRIM)
C X3030 SOFFIT WOOD TRIM 1" X 1 1/2" - WD0073 @
11' - 1" AFF (TOP OF TRIM)
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
1
0
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I401
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED CASEWORK
PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/2" = 1'-0"1ENLARGED CASEWORK PLAN
N
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
INDICATES STAINLESS STEEL (SST) COUNTERTOP
LEGEND
INDICATES SOLID SURFACE (SS) COUNTERTOP
DATUM POINT
WAINSCOTT WOOD WALL CLADDING - WD0073
MAD200V @2' - 10" AFF + WOOD TRIM 1" X 1
1/2" - WD0073C X3030
RX10368
C X3030 WOOD TRIM 1" X 1 1/2" - WD0073 @ 9' - 1" AFF
(TOP OF TRIM)
C X3030 SOFFIT WOOD TRIM 1" X 1 1/2" - WD0073 @
11' - 1" AFF (TOP OF TRIM)
1' - 3"12' - 5 1/2"5' - 9"2' - 3"3' - 4"
4' - 0"1' - 7"5' - 1 3/4"1' - 7"
2"4 1/2"
1' - 7"6' - 0 1/2"
5
1
/
2
"
4'
-
6
1
/
4
"
3'
-
9
"
5'
-
0
"
4'
-
4
1
/
2
"
1"1"2' - 11 1/4"2"1"
2'
-
1
3
/
4
"
7'
-
6
"
1'
-
3
"
2'
-
8
"
2'
-
6
1
/
2
"
2'
-
7
"
3'
-
9
"
2'
-
6
1
/
2
"
3'
-
6
1
/
2
"
9'
-
0
"
11' - 11"
2' - 6 1/2"
2' - 6 1/2"
2' - 6 1/2"
4' - 4 1/2"1' - 1 1/4"6' - 5 1/2"
3"
2'
-
2
"
1
3
/
4
"
ø 4"
ø 4"
ø 2"
ø 4"ø 3"ø 3"
ø 3"
ø 3"
ø 3"
ø 4"
ø 4"
ø 4"
ø 4"
ø 4"
ø 4"
ø 4"ø 4"
ø 2"
ø 2 1/4"
1' - 5 1/4"
11
1
/
2
"
9
3
/
4
"
1' - 0"
6' - 5"
8"
2'
-
1
"
8"
2'
-
1
"
8"
2'
-
1
"
2' - 5 1/4"3' - 10"2' - 7 3/4"3' - 6 1/2"4' - 1 3/4"1' - 7 1/4"
2
3
/
4
"
4"
9
3
/
4
"
9
3
/
4
"
9
3
/
4
"
6' - 10 3/4"
4' - 2 1/4"2' - 8 1/2"1
I502A
CP0002
C 10020
10"
4'
-
5
1
/
2
"
8 1/2"1' - 3"
5"
EQ
EQ
4"
1' - 2 1/2"
3' - 10"2' - 3 1/2"
4"
1'
-
1
"
1'
-
7
"
5"
4'
-
2
"
5"
11
1
/
2
"
2'
-
9
1
/
2
"
1' - 5 1/4"1' - 11"
4'
-
4
1
/
2
"
4"
C X3020
CPX066
r 1"r 1"
BACKBAR
CPX066
C 17826 C 23411
C 21960
C 23433
CPX066
CPX066
CPX066
C 17807
C 18720
CPX066
CPX066
C 18886
CPX066
C 21948
C 20271
C 18871
C 17807
C 19338CX19282
C 17807
#4
BRUSHED
16GA
CPX066
#4
BRUSHED
16GA
CPX066
C 17809
#4
BRUSHED
16GA
CPX066
CPX066
CPX066
C 17809
#4
BRUSHED
16GA
1"
1"1' - 3"1"
A. GENERAL CONTRACTOR TO NOTIFY CONSTRUCTION MANAGER IMMEDIATELY
IF A DISCREPANCY EXISTS BETWEEN CASEWORK SHOP DRAWINGS, EXITING
SITE CONDITIONS, ARCHITECTURAL DRAWINGS OR BUILT FIXTURES. ALL
DIMENSIONS SHALL BE FIELD VERIFIED BY GC PRIOR TO SHOP DRAWINGS
PRODUCTION.
B. STARBUCKS CONSTRUCTION MANAGER TO COORDINATE AND SCHEDULE
CASEWORK DELIVERY DATE. GENERAL CONTRACTOR TO CONFIRM
CASEWORK DELIVERY DATE WITH CASEWORK MANUFACTURER AT FOUR (4)
WEEKS PRIOR AND THEN ONE (1) WEEK PRIOR TO SCHEDULED DATE OF
DELIVERY.
C. STARBUCKS CONTRACTS DIRECTLY WITH CASEWORK VENDOR TO SUPPLY
CASEWORK LISTED IN THE CASEWORK SCHEDULE, UNLESS OTHERWISE
NOTED.
D. CASEWORK VENDOR TO PROVIDE COMPLETE SHOP DRAWINGS AND
INSTALLATION PACKAGE TO GENERAL CONTRACTOR TO FACILITATE
PROPER INSTALLATION.
E. ALL CASEWORK BOX BASE / TOE KICKS SHALL BE SET AND LEVELED USING 1/4"
(6 MM) NON-ABSORBENT PLASTIC SHIMS PROVIDED BY CASEWORK VENDOR.
F. SEE INTERIOR FINISH ELEVATIONS AND SCHEDULES FOR LOCATION AND
TAGGING OF WALL TREATMENTS BY CV AND OTHERS.
G. SEE REFLECTED CEILING PLAN FOR CASEWORK SOFFIT
LOCATIONS.
H. REFERENCE PLUMBING AND ELECTRICAL PLANS FOR PLACEMENT OF
ELECTRICAL, DATA AND PLUMBING ON FRONT AND BACKLINE OF BAR.
I. PROVIDE ACCENT LIGHTING AT FRONT EDGE OF BAR. SEE INTERIOR
ELEVATIONS AND ELECTRICAL FOR ADDITIONAL INFORMATION.
J. CASEWORK VENDOR TO ENGINEER PROPER COUNTERTOP SUPPORT AT
ESPRESSO BAR AND OTHER WORKSTATIONS PER STARBUCKS MINIMUM
PERFORMANCE REQUIREMENTS.
K. REFER TO CASEWORK INSTALLATION MANUAL PROVIDED BY CASEWORK
VENDOR FOR COMPLETE INSTALLATION INSTRUCTIONS.
L. SEE SHEET I-601 FOR SCHEDULES.
M. G.C. TO MODIFY CASEWORK PER CASEWORK DETAILS.
N. STORAGE RACKS OR SHELVINGS OVER 5'-9" IN HEIGHT SHALL BE
MECHANICALLY SECURED.
GENERAL NOTES
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
1
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I401A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED CASEWORK
PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
N
1/2" = 1'-0"1ENLARGED COUNTERTOP DIMENSION PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
CONSTRUCTION.
B. ALL DIMENSIONS ARE TO BE TAKEN FROM A DESIGNATED DATUM POINT.
C. DIMENSIONS ARE TO FACE OF FINISHED SURFACE UNLESS OTHERWISE
NOTED.
D. DIAPER CHANGING STATION IS TO BE INSTALLED PER MANUFACTURER’S
INSTRUCTIONS. UNIT IS TO BE FASTENED TO STRUCTURE AT ALL SIX CHASSIS
ATTACHMENT POINTS. (IF APPLICABLE PER PROJECT SCOPE)
E. LOCATE DIAPER CHANGING STATION AS SHOWN TO ALLOW NECESSARY
CLEARANCE FOR OPERATION OF ALL RESTROOM FIXTURES. LOCATION SHALL
NOT IMPEDE ACCESS, EGRESS, OR DOOR SWING. (IF APPLICABLE PER
PROJECT SCOPE)
F. ALL RESTROOM ACCESSORY MOUNTING HEIGHTS AND CLEARANCES SHALL
COMPLY WITH THE ACCESSIBILITY REQUIREMENTS OF THE LOCAL
JURISDICTION.
GENERAL NOTESKEYNOTES
1 60" ACCESSIBLE TURNING RADIUS.
2 30" X 48" CLEAR FLOOR SPACE.
3 WATER CLOSET CLEAR FLOOR SPACE.
4 NEW WALL TILE.
5 RELOCATED ELECTRICAL HAND DRYER.
6 NEW LAVATORY FAUCET. FLOW RATE NOT TO EXCEED 0.5 GPM AT
60 PSI
7 NEW LAVATORY.
8 NEW MIRROR.
9 NEW WATER CLOSET.
10 NEW GRAB BAR.
11 NEW RESTROOM DOOR.
12 NEW TOILET SEAT COVER DISPENSER.
13 NEW TOILET PAPER DISPENSER.
14 NEW TILE BASE.
15 NEW RESTROOM WALL SCONCE, CENTER SCONCE ABOVE MIRROR
16 NEW SINK MOUNTED SOAP DISPENSER.
17 NEW DOOR MOUNTED COATHOOK @ 4' -0" AFF
18 NEW WALL HYDRANT, CENTER BENEATH LAVATORY SINK
2' - 0"1' - 0"
3' - 0"
2'
-
9
"
1'
-
5
3
/
4
"
1' - 6"
2'
-
9
"
1'
-
7
"
3'
-
5
"
1'
-
6
"
3' - 3"
6"4' - 0"
3' - 3 1/2"5 1/4"
1' - 6 1/4"
2'
-
3
"
2'
-
9
"
1'
-
6
"
3'
-
3
"
2'
-
9
"
ELECTRIC HAND
DRYER FRONT ELEVATION
4'
-
0
"
HAND SINK
FRONT ELEVATION
COAT
HOOK ELEVATION
HAND SINK
SIDE ELEVATION
TOILET
FRONT ELEVATION
TOILET
SIDE ELEVATION
3'
-
6
"
CEMENTITOUS BACKER
BOARD
CONTINUOUS WATERPROOF
MEMBRANE. EXTEND
12" (305mm) UP WALL.
WALL TILE PER SCHEDULE.
ADHERE TO WALL PER
MFR'S RECOMMENDATIONS.
COVED TILE BASE PER
SCHEDULE. ADHERE TO
WALL PER MFR'S
RECOMMENDATIONS.
3/8" RADIUS AT COVED BASE
FINISH FLOOR PER SCHEDULE
CONTINUOUS WATERPROOF
MEMBRANE APPLIED TO
SUBFLOOR. EXTEND EDGE
TO 12" (305mm) OFFSET
FROM WALL.
CONCRETE SLAB
WALL TYPE PER LEGEND
I402
6
7 5
4
W/C CLEARANCE
4' - 8"
W/
C
C
L
E
A
R
A
N
C
E
5'
-
0
"
2' - 6"
4'
-
0
"
CLR.
4' - 0"
18" MIN
WHEEL CHAIR TURNING SPACE
ø 5' - 0"
2
1
3
17
"
-
1
8
"
1'
-
5
"
2'
-
9
1
/
2
"
6"
9'
-
0
"
B 15116
4 Q 20242
149
10 13 12
6"
9'
-
0
"
B 15116
4 Q 20242
14
3'
-
3
1
/
4
"
2'
-
9
"
6"
6'
-
9
"
9'
-
0
"
B 15116
4
14
D 10190 15
11
8
15
16
7
6
Q 20242
WD0073
SW6071 (SG)
1'
-
6
"
EQEQ
184'
-
0
"
F 10756 17
1'
-
5
"
2'
-
9
1
/
2
"
2'
-
9
"
6"
9'
-
0
"
B 15116
4 Q20242
14
15
7
6
16
5
10
9
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
1
4
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I402
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED RESTROOM
ACCESSIBILITY PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/8" = 1'-0"1MOUNTING HEIGHTS FOR RESTROOM
ACCESSORIES
6" = 1'-0"2INTEGRAL TILE BASE AT TILED WALL
3/4" = 1'-0"3ENLARGED RESTROOM ACCESSIBILITY PLAN
N
1/2" = 1'-0"4CUSTOMER RR ELEVATION A
1/2" = 1'-0"5CUSTOMER RR ELEVATION B
1/2" = 1'-0"6CUSTOMER RR ELEVATION C
1/2" = 1'-0"7CUSTOMER RR ELEVATION D
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
I402A
4
5 3
2
3
1
4'
-
0
"
W/C CLEARANCE
5' - 0"
CL
E
A
R
A
N
C
E
4'
-
8
"
CL
R
.
4'
-
0
"
WHEELCHAIR TURNING SPACE
ø 5' - 0"
3
2
18" MIN
2' - 6"
17"-18"
2'
-
9
"
6"
3'
-
3
1
/
4
"
6'
-
9
"
1'
-
5
"
2'
-
9
1
/
2
"
9'
-
0
"
EQ EQ
8
15
16
7
6
10
9
B X1979514
Q 114694
1'
-
6
"
18
Q 11469
10 13 12
9 B X1979514
4
9'
-
0
"
6"
1'
-
5
"
2'
-
9
1
/
2
"
9'
-
0
"
6"
D 10190 05
Q 11469
B X1979514
11
4
WD0073
SW6071 (SG)
F 10756
4'
-
0
"
17
6"
9'
-
0
"
3'
-
5
1
/
2
"
2'
-
9
"
15
16
5
6
6'
-
9
"
B X1979514
Q 114694
A. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
CONSTRUCTION.
B. ALL DIMENSIONS ARE TO BE TAKEN FROM A DESIGNATED DATUM POINT.
C. DIMENSIONS ARE TO FACE OF FINISHED SURFACE UNLESS OTHERWISE
NOTED.
D. DIAPER CHANGING STATION IS TO BE INSTALLED PER MANUFACTURER’S
INSTRUCTIONS. UNIT IS TO BE FASTENED TO STRUCTURE AT ALL SIX CHASSIS
ATTACHMENT POINTS. (IF APPLICABLE PER PROJECT SCOPE)
E. LOCATE DIAPER CHANGING STATION AS SHOWN TO ALLOW NECESSARY
CLEARANCE FOR OPERATION OF ALL RESTROOM FIXTURES. LOCATION SHALL
NOT IMPEDE ACCESS, EGRESS, OR DOOR SWING. (IF APPLICABLE PER
PROJECT SCOPE)
F. ALL RESTROOM ACCESSORY MOUNTING HEIGHTS AND CLEARANCES SHALL
COMPLY WITH THE ACCESSIBILITY REQUIREMENTS OF THE LOCAL
JURISDICTION.
GENERAL NOTES
KEYNOTES
1 60" ACCESSIBLE TURNING RADIUS.
2 30" X 48" CLEAR FLOOR SPACE.
3 WATER CLOSET CLEAR FLOOR SPACE.
4 NEW FRP.
5 RELOCATED ELECTRICAL HAND DRYER.
6 NEW LAVATORY FAUCET. FLOW RATE NOT TO EXCEED 0.5 GPM AT
60 PSI
7 NEW LAVATORY.
8 NEW MIRROR.
9 NEW WATER CLOSET.
10 NEW GRAB BAR.
11 NEW RESTROOM DOOR.
12 NEW TOILET SEAT COVER DISPENSER.
13 NEW TOILET PAPER DISPENSER.
14 NEW TILE BASE.
15 NEW RESTROOM WALL SCONCE, CENTER SCONCE ABOVE MIRROR
16 NEW WALL MOUNTED SOAP DISPENSER.
17 NEW DOOR MOUNTED COATHOOK @ 4' -0" AFF
18 NEW WALL HYDRANT, CENTER BENEATH LAVATORY SINK
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
1
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I402A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ENLARGED RESTROOM
ACCESSIBILITY PLAN
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
N
3/4" = 1'-0"1ENLARGED RESTROOM ACCESSIBILITY PLAN1
1/2" = 1'-0"2PARTNER RR ELEVATION A
1/2" = 1'-0"3PARTNER RR ELEVATION B1/2" = 1'-0"4PARTNER RR ELEVATION C
1/2" = 1'-0"5PARTNER RR ELEVATION D
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
HEAVY-DUTY GRID
NOTES:
1. LIGHT FIXTURES OR DIFFUSERS IN EXCESS
OF 56 LBS REQUIRE (4) 12 GAUGE HANGER
WIRES.
2. SUSPENDED CEILING TO COMPLY WITH
ASCE 7-16 SECTION 13.5.6.2.2., ASTM C636,
CISCA DESIGN REQUIREMENTS
3. CEILINGS SHALL BE SPECIAL INSPECTED
PER SECTION 11A.1.3.9 OF ASCE 7.16
(SEE ADDITIONAL NOTES ON RCP)
(2) 12 GAUGE HANGER
WIRES TO STRUCTURE
ABOVE - AT ALTERNATE
CORNERS OF ALL 2X4
LIGHT FIXTURES AND
HVAC DIFFUSERS
2" OVERSIZED
RING ADAPTER AT
SPRINKLER HEAD
INSTALL COMPRESSION STRUT
EA. DIRECTION OR EVERY 144
S.F. OF CEILING AREA PER CBC
STANDARDS 47-18
12 GA. WIRES @ 12'-0" O.C.
SPLAYED 45° FROM CEILING
PLANE
CROSS RUNNER @ 2'-0" O.C.
45° -
TYP
.
WA
L
L
MAIN RUNNER @ 4'-0" O.C.
NOTE:
1. ALL INTERIOR WALL & CEILING FINISHES SHALL BE FLAME SPREAD CLASS III MIN.
2. SUSPENDED T-BAR SYSTEM SHALL BE 25 GA. MIN.
3. SUSPENDED CEILING TILE SYSTEM TO COMPLY WITH ICC-ESR #1308
4. ALL 24" X 48" LIGHT FIXTURES & 24" X 24" HVAC DIFFUSERS SHALL BE
SUPPORTED BY A MIN. OF (2) HANGERS @ OPPOSITE CORNERS - CEILING
SYSTEM SHALL NOT SUPPORT OTHER ITEMS.
5. CEILING SYSTEM GRID TO BE HEAVY DUTY.
12 GA HANGER WIRE @ 4'-0" O.C.
ALONG EACH MAIN RUNNER
6'-0" MAX.
CEILING SYSTEM GRIDTO
BE HEAVY DUTY.
++
1/2 " =.5 L=5' MAX. x 12"=60
PROVIDE COMPRESSION
STRUTS @ 12'-0" O.C.
EACH DIRECTION (OR 144.
S.F. AND WITH 6'-0" OF
WALLS
60/.5 = 120 < 200
L/R = < 200
NOTE:
'X' CUT BOTTOM OF
CONDUIT (1" DEEP) AND FIT
SNUG TO T-BAR
INTERSECTION
(2) #8 WOOD SCREWS
1" DIA. RIGID CONDUIT
COMPRESSION POST
JOIST, PURLIN OR SUB-PURLIN
(SEE ADDITIONAL NOTES ON RCP)
SUSPENDED CEILING TILE SYSTEM TO COMPLY WITH ICC-ESR #1308
SPLICE AS NEEDED WITH 3/4"
DIA.BY 6" CONDUIT AND #8
MACHINE SCREWS AND NUTS
VA
R
I
E
S
(
V
.
I
.
F
.
)
B
A
HANGER WIRE - PARALLEL TO
WALL @ 4'-0" O.C. - TYP.
MAIN RUNNER - POP RIVET EACH MAIN
RUNNER OR CROSS TEE TO WALL
ANGLE - PROVIDE ADDTIONAL
CLOSURE ANGLES AS REQUIRED
ACCOUSTICAL PANEL - TYP.
MAIN RUNNER - DO NOT ATTACH TO
WALL ANGLE
WALL OR SOFFIT - SEE PLAN
CONTINUOUS 2" X 2" ANGLE WITH #10
SELF-TAPPING SCREWS AT EACH
STUD - TYP.
TYP.
8" MAX.
ATTACHED
(2) ADJACENT WALLS
UNATTACHED
OPPOSITE WALLS
NOTE:
MAIN RUNNERS SHALL BE ATTACHED AT (2) ADJACENT WALLS AS SHOWN IN
CONDITION 'A'
MAIN RUNNERS SHALL BE UNATTACHED AT OPPOSITE WALLS AS SHOWN IN
CONDITION 'B'
SEE ADDITIONAL NOTES ON REFLECTED CEILING PLAN - SHEET I-121
3/4" CLR.
SPREADER BAR AS REQUIRED TO
PREVENT SPREADING
TABLE FOR NON-BEARING METAL STUDS SSMA PRODUCTS
ICC ESR #2054
5 PSI (SIZING PERTAINS TO ALL 'S' WALL TYPES)
STUD SIZE AND GAUGE SPACING MAX. HT.
3625125-18 (3 5/8" X 25 GA.) 16" O.C. 14'-4"
3625125-33 (3 5/8" X 20 GA.) 16" O.C. 16'-5"
3625125-43 (3 5/8" X 18 GA.) 16" O.C. 18'-0"
4005125-18 (4" X 25 GA.) 16" O.C. 15'-4"
4005125-33 (4" X 20 GA.) 16" O.C. 18'-4"
4005125-43 (4" X 18 GA.) 16" O.C. 19'-5"
6005125-18 (6" X 25 GA.) 16" O.C. 19'-9"
6005125-33 (6" X 20 GA.) 16" O.C. 24'-6"
6005125-43 (6" X 18 GA.) 16" O.C. 28'-3"
SEE DETAIL 13 AND 15 THIS SHEET FOR FULL HEIGHT WALLS.
FULL THICKNESS BATT
INSULATION - ONLY WHERE
INDICATED ON PLANS AND
SPECIFICATIONS
FRAMING PER PLAN
FINISH FLOOR1/
4
"
M
A
X
.
5/8" TYPE 'X' GYP. BD.
SHOT PINS - HILTI OR EQUAL
@ 24" O.C.
LARR. #25646 - ESR # 1663
25 GA. FLOOR TRACK -
CONTINUOUS
WOOD BLOCKING
BETWEEN ROOF
TRUSSES AS
REQUIRED
CONTINUOUS SLIP TRACK
FRAMING PER PLAN- 1" MINIMUM CLEAR FROM
ROOF STRUCTURE - TO ALLOW ROOF
DIAPHRAM MOVEMENT - SHOT PIN - ICC
ESR -1752
5/8" TYPE 'X' GYP. BD. - WHERE OCCURS
DO
N
O
T
A
T
T
A
C
H
G
Y
P
.
B
D
.
AB
O
V
E
T
H
I
S
P
O
I
N
T
(2) #10 X 2" WOOD SCREWS @ 24" O.C.
ROOF FRAMING OR OTHER
STRUCTURAL MEMBER
SIMPSON#A35
FRAMING ANCHOR @
EA END. USE (12) 8-d X
1-1/2" NAILS, TYP
5/8" TYPE 'X' GYP. BD.
ATTACH BRACING TO
CONTINUOUS 20 GA. TOP
TRACK WITH (2) #10 S.M.S.
WALL BRACING @ 45 DEG. @
48" O.C. IN ALTERNATING
DIRECTIONS - SAME STUD
GAUGE AS WALL
FRAMING PER PLAN
I501
7
I501
6
FRAMING PER PLAN
5/8" TYPE 'X' GYP BD.
EXISTING ROOF & STRUCTURE
CONTINUOUS SLIP TRACK
ICC-ESR #2054
LARR # 25631
CEILING PER PLAN
6"
M
I
N
.
5/8" TYPE 'X' GYP
BD. - EXTEND TO
UNDERSIDE OF ROOF
STRUCTURE WHERE
NO CEILING OCCURS
NOTES:
1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT
BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED.
2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL
TOILET ROOMS AND WET WALLS.
3. USE 5/8" TYPE 'X' GYP. BD. THROUGHOUT - U.N.O.
4. PROVIDE SOUND BATT INSULATION AT ALL OFFICE AREAS & RESTROOMS
WALLS
AND CEILINGS.
SIM.
NOTES:
1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT
BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED.
2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL
TOILET ROOMS AND WET WALLS.
3. USE 5/8" TYPE 'X' GYP. BD. THROUGHOUT - U.N.O.
4. PROVIDE SOUND BATT INSULATION AT ALL OFFICE AREAS & RESTROOMS
WALLS
AND CEILINGS.
FRAMING PER PLAN -
ATTACH BRACING TO
CONTINUOUS TOP TRACK
WITH
(2) #10 S.M.S.
METAL STUD WALL BRACING
@ 48" O.C. IN ALTERNATING
DIRECTIONS - GA. TO MATCH
WALL
ATTACH BRACING TO
BOTTOM CHORD OR
BLOCKING WITH (2) #10 x 1"
SCREWS
BATT INSULATION AT
UNDERSIDE OF ROOF
DECK AS REQUIRED -
REFER TO T-24 FOR R
VALUE
PROVIDE 2X6 BLOCKING AS
REQUIRED AT PARALLEL AND
PERPENDICULAR TRUSS
CONDITIONS WITH LUS26
EACH END TO WEB
STIFFENER
CEILING PER PLAN - REFER
TO I103 FOR CEILING TYPE
AND HEIGHT.
5/8" TYPE 'X' GYP. BD.
6"
M
A
X
.
TYP.45°
ICC-ESR #2054
LARR # 25631
FLOOR FINISH PER PLAN
EXISTING TOP OF SLABI501
6
12
'
-
0
"
M
A
X
.
I501
8
FINISH FLOOR
5/8" TYPE 'X' GYP. BD.
CONTINUES 12" ABOVE
ACOUS.
CEILING
SEE PLAN FOR STUD
SIZE AND TRACK -
ICC-ESR #2054
5/8" WATER RESISTANT GYP.
BOARD
(E) DEMISING WALL
EXISTING CONCRETE SLAB
TYPICAL INTERIOR WALL ASSEMBLY
WALL & CEILING ASSEMBLY NOTES
1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT
BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED.
2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL
TOILET ROOMS.
3. USE 5/8" THICK GYPSUM BOARD THROUGHOUT EITHER TYPE "X" OR UN-RATED
AS NOTED ON SHEET
4. PROVIDE SOUND BATT INSULATION OVER ALL OFFICE AREAS & RESTROOMS.
25 GAUGE FLOOR
TRACK
ANCHOR W/ 5/32" SHOT
PINS AT 36" ON
CENTER
PROVIDE 2X6 BLOCKING AS REQUIRED AT
PARALLEL AND PERPENDICULAR TRUSS
CONDITIONS W/LUS26 EA. END TO WEB
STIFFENER
ATTACH BRACING TO BOTTOM CHORD OR
BLOCKING WITH (2) #10 x 1" SCREWS
REFER TO PLAN A101 AND
METAL STUD TABLE - SEE
5/I500
(E) GYP BD
CEILING
I501
6
FINISH FLOOR
5/8" TYPE 'X' GYP. BD.
CONTINUES 12" ABOVE
ACOUS.
CEILING
SEE PLAN FOR STUD
SIZE AND TRACK -
ICC-ESR #2054
5/8" WATER RESISTANT GYP.
BOARD
(E) DEMISING WALL
EXISTING CONCRETE SLAB
TYPICAL INTERIOR WALL ASSEMBLY
WALL & CEILING ASSEMBLY NOTES
1. ALL INTERIOR WALLS TO HAVE GYPSUM BOARD EXTEND TO PROVIDE TIGHT
BUTT JOINT TO FLOOR SLAB. NO GAP IN EXCESS OF 1/4" WILL BE ALLOWED.
2. PROVIDE WATER RESISTANT GYPSUM BOARD AT THE INTERIORS OF ALL
TOILET ROOMS.
3. USE 5/8" THICK GYPSUM BOARD THROUGHOUT EITHER TYPE "X" OR UN-RATED
AS NOTED ON SHEET
4. PROVIDE SOUND BATT INSULATION OVER ALL OFFICE AREAS & RESTROOMS.
25 GAUGE FLOOR
TRACK
ANCHOR W/ 5/32" SHOT
PINS AT 36" ON
CENTER
ATTACH BRACING TO
CONTINUOUS TOP TRACK
WITH (2) #10 S.M.S.
WALL BRACING AT 45 DEG.
SPACED AT 48" O.C. IN
ALTERNATING DIRECTIONS,
SAME STUD GAUGE AS WALL
PROVIDE 2X6 BLOCKING AS REQUIRED AT PARALLEL
AND PERPENDICULAR TRUSS CONDITIONS W/LUS26
EA. END TO WEB STIFFENER
ATTACH BRACING TO BOTTOM CHORD OR BLOCKING
WITH (2) #10 x 1" SCREWS
REFER TO PLAN A101 AND
METAL STUD TABLE - SEE
5/I500
(E) GYP BD
CEILING
I501
6
6" MTL STUD 20GA @16" O.C.
GYP.BD CEILING HEIGHT
PER SHEET I103
ACT CEILING HEIGHT
PER SHEET I103
24
"
TYP.
45°
CONT. 6" MTL STUD 20GA
(3) #10 SMS @ EA
CONNECTION, TYP.
1 1/2" X 1"
WOOD TRIM
CONT. 3 5/8" MTL STUD 20GA
7 1/4"
8 3/8"
13
1
/
8
"
10
7
/
8
"
7
1
/
8
"
6"
(CONT.) LED STRIP
LIGHT PER SHEET I103
3" = 1'-0"1FIXTURE BRACING
12" = 1'-0"2SUSPENDED CEILING DETAIL
12" = 1'-0"4COMPRESSION STRUT
1 1/2" = 1'-0"3T-BAR CEILING
12" = 1'-0"5METAL STUD WALL TABLE
1 1/2" = 1'-0"6BOTTOM TRACK DETAIL
1 1/2" = 1'-0"7TOP TRACK DETAIL
1 1/2" = 1'-0"8TOP TRACK DETAIL
3/8" = 1'-0"9FULL HEIGHT WALL
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
1
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I501
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
INTERIOR DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/8" = 1'-0"13TYPICAL INTERIOR WALL3/8" = 1'-0"16TYPICAL INTERIOR FURRED WALL AND
CEILING FRAMING - 2
3/8" = 1'-0"19TYPICAL INTERIOR FURRED WALL AND
CEILING FRAMING 3" = 1'-0"11ENLARGED SOFFIT TRIM DETAIL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
6" MTL STUD 20GA @
16" O.C.
DRYWALL SCREW
BACKBAR WALL PER
SHEET A101
EXISTING ROOF & ROOF
STRUCTURE TO REMAIN
4X WOOD BLOCKING - TYP.
PROVIDE 1X WEB FILLER AS
NEEDED (TYP.)
GYP.BD CEILING HEIGHT
PER SHEET I103
ACT CEILING HEIGHT
PER SHEET I103
2'
-
0
"
6"
TYP.
45°
3 5/8" MTL STUD
20GA @ 16" O.C.(2) #10 SMS @
24" O.C.
3 5/8" ALTERNATE BRACING MTL STUD
20GA @ 48" O.C.
(3) #10 SMS @ EA
CONNECTION, TYP.
6FT MAX SPAN6FT MAX SPAN
CONT. 6" MTL STUD 20GA
(4) #10 SMS @ EA
CONNECTION, TYP.
CONT. 6" MTL
STUD 20GA
(2) #10 SMS @
24" O.C.
1 1/2" X 1" WOOD TRIM
I501
11
Sim
EXISTING STOREFRONT
TO REMAIN
(E) STOREFRONT @
12' - 6 3/4" AFF (V.I.F.)
ATTACH TO EXISTING
STOREFRONT WALL GYP
5
1
/
4
"
CONT. 3 5/8" MTL STUD 20GA
WEB FILLER WHEN
APPLICABLE
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
1
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I501A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
INTERIOR DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1 1/2" = 1'-0"1GYP.BD CEILING FRAMING AT ENGINE
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
DO NOT BLOCK GROMMET OPENING.
CUT ANGLE AS REQUIRED TO MAINTAIN
MIN. 1/2" (13MM) CLEAR AROUND OPENING.
MECHANICALLY FASTEN
COUNTER-SUNK
CORROSION RESISTANT
FASTENERS AT 6"(150MM)
O.C. WITH 3/4" (19MM)
EMBEDMENT.
MECHANICALLY FASTEN ANGLE TO
COUNTERTOP SUBSTRATE OR EPOXY
FASTEN ITO COUNTERTOP.1 1/2" X 1 1/2" (38MM X 38MM)
CORROSION RESISTANT
STEEL ANGLE
UNDERCOUNTER
REFRIGERATOR
.
1/2" (13MM) PREFERRED
OFFSET DISTANCE FROM
EDGE OF COUNTERTOP
COUNTERTOP DEPTH MAY VARY
COUNTERTOP
ABOVE
UNDERCOUNTER
REFRIGERATOR
STEEL ANGLE
CENTERED ON
REFRIGERATOR
EQ
.
EQ
.
FRONT EDGE OF COUNTERTOP TO FACE OF ANGLE
2' - 5" (737MM)
SECTION VIEW PLAN VIEW
NOTES
1. 24" (610MM) 1 1/2" X 1 1/2" (38MM X 38MM) STEEL ANGLE TO BE USED WITH SINGLE DOOR REFRIGERATORS.
2. 48" (1220MM) 1 1/2" X 1 1/2" (38MM X 38MM) STEEL ANGLE TO BE USED WITH DOUBLE DOOR REFRIGERATORS.
SE
E
N
O
T
E
S
B
E
L
O
W
FRONT EDGE OF
COUNTERTOP
ABOVE
.3
/
4
"
NOTES:
CABINETS TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS
2'
-
1
0
"
2'
-
2
"
ELECTRICAL
OUTLET
2X6
SUPPORT
W/SHIM
TILE BASE
2'-10" AFF
(BACKBAR
COUNTERTOP)
COUNTERTOP WITH INTEGRAL BACKSPLASH
1/4" GREEN BOARD TILE SUBSTRATE BY GC
PORCELAIN TILE/CORIAN WALL CLADDING
BETWEEN TOP OF BACKSPLASH AND BOTTOM OF
PAINTED FINISH - SEE INTERIOR ELEVATIONS
I502
17
1 1'-7" AFF (CW SUPPLY)
2 1'-6" AFF (CWF SUPPLY)
3 1'-5" AFF (HW SUPPLY)
4 VARIES: 1/4" PER FT. FALL (ABS WASTE LINE)
5 45 LBS DEAD LOAD FOR LIQUID STORAGE OVER AND ABOVE THE
CASEWORK ITSELF.
6 A LIVE LOAD OF A PARTNER EITHER PULLING AND/OR CLIMBING ON
THE CASEWORK.
7 SEISMIC ACCELERATION CONDITIONS AT THE SITE.
8 APPLY FRP TO WALL BEHIND CABINETS -SEE I105 WALL FINISH
PLAN.
10"X10" (250MM X 250MM) BACKER BOARDS.
ATTACH TO PLYWOOD SUBSTRATE WITH
SILICONE ADHESIVE AND WOOD SCREWS.
SILICONE PERIMETER.
INTERIOR FACE OF DIEWALL
FINISHED FLOOR
PUMP ATTACHED TO BACKER BOARD
WITH ASSEMBLY COMPONENTS
SEE NOTES ABOVE FOR
ASSEMBLY ITEMS
NOTES:
1. LOCATE PUMP WITHIN CORD LENGTH LIMIT. ORIENT WITH
PUMP HEAD LEFT, RIGHT AND AT BOTTOM. LOOSEN PUMP
HEAD CLAMP, ROTATE AND RE-TIGHTEN AS REQUIRED PER
ORIENTATION TO PROVIDE FRONT ACCESS TO FLOW.
ADJUSTMENT WITHIN CORD LENGTH LIMIT.
2. USE LOCKTITE ON ISOLATOR THREADS. DO NOT OVER
TIGHTEN.
3. LOOSEN PUMP HEAD CLAMP, ROTATE AND RE-TIGHTEN AS
REQUIRED FOR PUMP ORIENTATION.
4. BACKER BOARD'S ASSEMBLY COMPONENTS INCLUDE:
(1) BACKER BOARDS
(4) TENETS, 1/4-20 VENDOR MOUNTED
(8) WOOD SCREWS #8 1-1/4" (32MM)
(4) NEOPRENE ISOLATORS, KARMAN RUBBER, K84-60
NEOPRENE
(4) LOCK NUTS, 1/4-20 NYLON
(4) WASHERS, 1/4" (7MM) FLAT
MI
N
.
6"
(
1
5
2
M
M
)
SECTION A - MILK DISPENSESECTION B - CUP LABELER
SECTION C - NUGGET ICE DISPENSESECTION D - SOFFIT
NOTE:
• CEILING HEIGHT 10'-0" MIN.
1. NUGGET ICE RIDE SYSTEM TO RUN IN
STANDARD SOFFIT
2. DMB TO BE MOUNTED ON FACE OF SOFFIT
• ACCESS PANEL TO BE SIZED TO AVOID
CONFLICT WITH LIGHTING COVE
ELEVATION
2'
-
6
"
M
I
N
.
2'
-
8
"
2'
-
0
"
2'
-
1
0
"
10
'
-
0
"
M
I
N
.
C
E
I
L
I
N
G
H
E
I
G
H
T
B A
DC
ACCESS
PANEL/DOOR
CEILING
SOFFIT
FRAMING, BLACK
ACCESS
PANEL/DOOR
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
FRAMING, BLACK
CL
E
A
R
1'
-
0
"
M
I
N
.
UNDER CABINET
STRIP LIGHTING
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
UNDER CABINET
STRIP LIGHTING
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
UNDER CABINET
STRIP LIGHTING
SEE INTERIOR
ELEVATIONS FOR HEIGHT
1"
WALL TILE - SEE ELEVATION FOR
WALL FINISH
FRAMING PER PLAN
5/8" GYPSUM BD.
2"
1 1/2" X 1" WOOD TRIM - SEE ELEVATION
FOR DETAIL
PAINT ABOVE TRIM SW9169-SG
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
1
8
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I502
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
CASEWORK DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1 1/2" = 1'-0"1UNDERCOUNTER REFRIGERATOR STOP INSTALLATION
1" = 1'-0"3WALL SECTION @ BACKBAR (SHELVING)
1 1/2" = 1'-0"13ESPRESSO PUMP MOUNTED AT DIE WALL
3/4" = 1'-0"7UPPER CABINET/SOFFIT ASSEMBLY -STANDARD
6" = 1'-0"17WOOD TRIM DETAIL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
34" MAX. AFF
METAL ANGLE,
TYP.
COUNTERTOP
SUBSTRATE
ALUM. Z-CLIPS, TYP.
FINISH PANEL
DIEWALL
COUNTERTOP
OPTIONAL LED STRIP
LIGHTING BY OTHERS
VARIES
MI
N
.
1/
2
"
4" (TYP.)
NOTE:
ALL COMPONENTS
FURNISHED BY
OTHERS AND
INSTALLED BY G.C.
UNLESS NOTED
OTHERWISE.
METAL BOTTOM TRIM
PER DETAILS
METAL CORNER TRIM
PER DETAILS
CUSTOMER
FACING SIDE
INTERIOR SIDE
HARDWOOD SLATS
1/2" PLYWOOD BACKER (TYP.)
.2 1/4"
.
.
.1 7/8"
.1/4"
.R=
1/2"5/
8
"
3/
1
6
"
.3/
4
"
HARDWOOD
SLATS ADHERED
TO SUBSTRATE /
STRUCTURE AND
MECHANICALLY
FASTED AS
REQUIRED
.1/8"
ELEVATION
24 STAVES, NO BUTT JOINTS
4' - 0 1/4"
4' - 0" BACKER
2'
-
5
"
A
NOT TO SCALE
ENLARGED SECTION PROFILEA
DIRECTION OF WOOD
GRAIN. TYP. ALL
SLATS
INTERIOR SIDE TO BE SECURED TO
SUBSTRATE / STRUCTURE PER DETAILS
HARDWOOD CONT. TOP CAP. ADHERE
TO WALL AND MECHANICALLY
FASTEN AS REQUIRED
EASE ALL EXPOSED EDGES
HEIGHT PER
ELEVATIONS
1/4" GAP FOR Z CLIP OR BLOCKING
SEALANT TO MATCH ADJACENT WALL FINISH
COVED TILE BASE PER SCHEDULE. ADHERE
TO WALL PER MFR'S RECOMMENDATIONS.
3/8" RADIUS AT COVED BASE
FINISH FLOOR PER SCHEDULE
CONCRETE SLAB
1"
METAL ANGLE TRIM ATTACHED AT BACK OF
PANEL WITH COUNTER SUNK FASTENER
WALL PER SHEET A101
WAINSCOT WOOD CLADDING
WD0073 MAD200-V
1 1/2"
REFER TO
INTERIOR ELEVATIONS
FLOATING WOOD SHELF BY
CASEWORK VENDOR (SEE
CASEWORK FINISH SCHEDULE).
SECURE TO STRUCTURE PER
MANUFACTURER'S INSTRUCTIONS.
2X10 BLOCKING CENTERED ON SHELF SURFACE
MOUNTING HEIGHT. SECURE TO EACH NAILER
USING (3) #10 3" WOOD SCREWS @ 4" (100 MM) O.C.
2X2 NAILERS, 14" (355 MM) LONG
SECURED TO WALL STUDS
USING (4) #10 3" WOOD SCREWS
AT 4" (100 MM) O.C. PER NAILER
HO
L
D
1'
-
0
3
/
4
"
REFER TO
INTERIOR ELEVATIONS
TY
P
.
1
1
/
2
"
4'
-
3
"
11
1
/
4
"
2
3
/
4
"
8 3/4"1' - 4 3/4"5 1/4"
2' - 6 1/2"
36
I
N
.
M
I
N
C
L
R
3'
-
1
1
/
4
"
C 23146
CPX066
5'
-
4
3
/
4
"
1/
2
"
3"
2'
-
5
3
/
4
"
1'
-
3
"
1'
-
4
"
1/
2
"
2' - 4 3/4"
C 18122
C 17747
C 18884
5'
-
4
3
/
4
"
PL0027
C X3060
1' - 3 3/4"1"1 1/4"
1"
1"
1' - 6"
I502A
3
5'
-
2
3
/
4
"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
1
9
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I502A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
CASEWORK DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
6" = 1'-0"1FINISH PANEL - BUILT-UP COUNTERTOP OVERHANG3/4" = 1'-0"9FINISH APPLICATION (MAD 200-V) ROUNDED SLAT W/ REVEAL3" = 1'-0"17WAINSCOT WOOD CLADDING
3" = 1'-0"3PARTNER REST SHELVES MOUNTING DETAIL3/4" = 1'-0"15ENLARGED PARTNER REST COUNTERTOP
DIMENSION PLAN 3/4" = 1'-0"11ENLARGED PARTNER REST CASEWORK
DIMENSION PLAN3/4" = 1'-0"19ENLARGED PARTNER REST UPPER
SHELVES DIMENSION PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3' - 6"3' - 6"3' - 6"
1'
-
1
1
1
/
2
"
2' - 2"10' - 6"
I502B
1B
I502B 1C
WD0073 WD0073
CTK0065 C 23009 A
I502B
PLAN VIEW
1' - 5"8 1/2"10' - 6"
4"3' - 6"3' - 6"3' - 6"
1'
-
3
1
/
2
"
1'
-
6
"
2"
6"
9
1
/
2
"
1' - 10"
2' - 0"
12' - 8"
1/
2
"
WD0073
C23009
FRONT ELEVATION VIEW
1'
-
6
"
1'
-
3
1
/
2
"
2'
-
9
1
/
2
"
6"
9
1
/
2
"
2"
1' - 10"
2' - 0"
1' - 5"8 1/2"
4"
2' - 1 1/2"
1/
2
"
SIDE ELEVATION VIEW
WD0073
CTK0065
1' - 9 1/2"2"2"
2"
2'
-
1
1
/
2
"
6"
WD0073 2'
-
9
1
/
2
"
C 23009
2' - 1 1/2"
2' - 0"
1' - 10"
SECTION VIEW
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
0
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I502B
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
CASEWORK DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"1ENLARGED BANQUETTE DIMENSION PLAN
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
METAL STARTER STRIP
EMBEDDED IN GROUT
WALL TILE PER SCHEDULE
CLEAR SEALANT
SOLID SURFACE
BACKSPLASH
CEMENTITOUS BACKER
BOARD
HEIGHT PER PLAN
WALL TYPE PER LEGEND
METAL STARTER STRIP
EMBEDDED IN GROUT
WALL TILE PER SCHEDULE
CLEAR SEALANT
STAINLESS STEEL
BACKSPLASH
CEMENTITOUS BACKER
BOARD
WALL TYPE PER LEGEND
PAINT PER SCHEDULE
CLEAR SEALANT
SOLID SURFACE
BACKSPLASH
CEMENTITOUS BACKER
BOARD
HEIGHT PER PLAN
WALL TYPE PER LEGEND
CEMENTITOUS BACKER BOARD
HEIGHT PER PLAN
WALL TYPE PER LEGEND
1 1/2" X 1" WOOD TRIM - WD0073
SEE INTERIOR ELEVATIONS
METAL STARTER STRIP
EMBEDDED IN GROUT
WALL TILE PER SCHEDULE
CLEAR SEALANT
PAINT PER SCHEDULE
CLEAR SEALANT
1 1/2"1"
1/4" (6MM) RADIUS
AT COVED BASE
CONCRETE CURB.
SEE PLAN FOR
HEIGHT, WIDTH
AND DEPTH.
FINISH FLOORING
PER SCHEDULE
CONCRETE SLAB
BASE AND TOP FINISH
TILE PER SCHEDULE
6" (150MM) +/- TYP. A.F.F.
CONTINUOUS WATERPROOF MEMBRANE. EXTEND 6"
(150mm) UP BASE
COVED TILE BASE PER SCHEDULE. ADHERE TO TOE
KICK BASE PER MFR'S RECOMMENDATIONS.
1/4" (6MM) RADIUS AT COVED BASE
FINISH FLOOR PER SCHEDULE
CONTINUOUS WATERPROOF MEMBRANE APPLIED
TO SUBFLOOR. EXTEND EDGE TO 12" (305mm)
OFFSET FROM CABINET BASE.
CONCRETE SLAB
ECO-GRIP FLOORING
ECO-GRIP EPOXY
ADHESIVE
16 GA. 2 1/4" (57MM)
WIDE STAINLESS STEEL
TRANSITION STRIP
TILE FLOOR
PER PLAN
SUBSTRATE MAY REQUIRE
SLOPING TO ADJUST HEIGHT
SO THAT ECO-GRIP AND
ADJACENT FLOOR ARE FLUSH
STAINLESS
FASTENER
LEAD ANCHOR
ECO-GRIP
SEALANT
ROUTE OUT
FLOORING TO DEPTH
OF TRANSITION STRIPCONCRETE
SLAB
SEALANT
SLOPE
STOREFRONT DOOR
WITH THRESHOLD
WALK-OFF MAT PER
SCHEDULE
STAINLESS STEEL
ANGLE
TILE FLOOR PER
SCHEDULE
PER TILE
MFR.
WATERPROOF MEMBRANE
ON WOOD SUBFLOOR ONLY
.
ECO-GRIP
FLOORING
ECO-GRIP
SEALANT
ECO-GRIP BASE CAP.
COLOR TO MATCH
ECO-GRIP FLOORING
STAINLESS STAPLE
OR POWDER COATED
STEEL FASTENER
BAR DIEWALL
INSTALL CASEWORK
DIEWALL PRIOR TO
ECO-GRIP FLOORING
ECO-GRIP EPOXY
ADHESIVE
3/8"
ROUTED
COVE
BASE AND
FLOORING PER
SCHEDULE
BAR FINISH
PANEL
CONCRETE SLAB
6"
(
1
5
0
M
M
)
M
I
N
.
CAFE BAR
SEALANT TO MATCH
ADJACENT WALL FINISH
COVED TILE BASE PER
SCHEDULE. ADHERE TO
WALL PER MFR'S
RECOMMENDATIONS.
1/4" (6MM) RADIUS AT
COVED BASE
FINISH FLOOR PER
SCHEDULE
CONCRETE SLAB
WALL TYPE PER LEGEND
CEMENTITOUS BACKER
BOARD
CONTINUOUS WATERPROOF
MEMBRANE. EXTEND
12" (305mm) UP WALL.
WALL TILE PER SCHEDULE.
ADHERE TO WALL PER
MFR'S RECOMMENDATIONS.
COVED TILE BASE PER
SCHEDULE. ADHERE TO
WALL PER MFR'S
RECOMMENDATIONS.
1/4" (6MM) RADIUS AT COVED BASE
FINISH FLOOR PER SCHEDULE
CONTINUOUS WATERPROOF
MEMBRANE APPLIED TO
SUBFLOOR. EXTEND EDGE
TO 12" (305mm) OFFSET
FROM WALL.
CONCRETE SLAB
WALL TYPE PER LEGEND
CONCRETE
SLAB
FLOOR SINK
HALF GRATE
STAINLESS STEEL
MEMBRANE CLAMP
ECO-GRIP EPOXY
ADHESIVE
ECO-GRIP
FLOORING
STAINLESS STEEL
SEDIMENT BUCKET WITH
LASER PERFORATIONS
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I503
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
FLOOR AND WALL
FINISH DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
6" = 1'-0"16SS BACKSPLASH TO TILE TRANSITION
6" = 1'-0"15SST BACKSPLASH TO TILE TRANSITION
6" = 1'-0"20SS CORIAN TO PAINT TRANSITION
6" = 1'-0"19TILE TO PAINT TRANSITION
6" = 1'-0"1TILE BASE AT CONCRETE CURB
6" = 1'-0"2INTEGRAL TILE BASE AT CABINET
12" = 1'-0"13ECO-GRIP TO TILE TRANSITION AT FOOT TRAFFIC AREA
6" = 1'-0"3TRANSITION - TILE TO WALK OFF MAT
6" = 1'-0"5ECO-GRIP BASE AT BAR DIEWALL6" = 1'-0"9INTEGRAL TILE BASE AT WALL
6" = 1'-0"11INTEGRAL TILE BASE AT TILED WALL
6" = 1'-0"14ECO-GRIP CLAMPING FLOOR SINK FLOOR FINISH DETAIL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
2 1/4"1' - 0"2 1/4"
1'
-
1
1
3
/
4
"
CABINET BOX
BASE
ECO-GRIP
FLOORING
DASHED LINE
INDICATES
COUNTERTOP
FRONT LINE
ABOVE
SST FLOOR SINK
W/CLAMPING
FEATURE
9
I503A
FLOOR SINK HALF GRATE
GRAVEL BACKFILL
NO-HUB CONNECTION
3" TAIL PIECE
CONC INFILL AND TRENCH FOR
BELOW GRADE UTILITIES
3/8" COVE RADIUS, TYP.
CABINET BASE
CABINET SIDE
FLOOR SINK W/CLAMPING FEATURE
(ZURN: Z1855)
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
1/
3
/
2
0
2
4
8
:
4
3
:
4
2
P
M
C:
\
U
s
e
r
s
\
b
s
a
u
n
\
H
e
s
t
i
a
A
t
e
l
i
e
r
D
r
o
p
b
o
x
\
P
r
o
j
e
c
t
s
\
S
t
a
r
bu
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
-
10
0
0
5
.
r
v
t
I503A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
FLOOR AND WALL
FINISH DETAILS
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
/
2
/
2
0
2
4
Revision Schedule
Rev Date By Description
B 1/2/24 MG City/County 1st round comments
NOT USED
NOT USED NOT USED
NOT USED NOT USED
NOT USED NOT USED NOT USED
NOT USEDNOT USED
NOT USED
NOT USED
1 1/2" = 1'-0"1ENLARGED UNDER COUNTER FLOOR SINK PLAN3" = 1'-0"9UNDER CABINET FLOOR SINK DETAIL
B
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
DIGITAL SCREEN
WALL MOUNTED
ORDER STATUS
BOARD MOUNTING
BRACKET
TOP OF ORDER STATUS
BOARD AT
6' - 6" (1980MM) A.F.F. MIN.,
7' - 0" (2135MM) A.F.F. MAX.
SEE INTERIOR ELEVATIONS
FOR ACTUAL DIMENSION
3/4" PLYWOOD BACKING
BEHIND WALL FINISH,
SECURED TO STRUCTURE
METAL RECESSED CABLE
MANAGEMENT AND POWER
STORAGE BOX. MINIMUM (1)
RECEPTACLES AND (1) DATA
PORT PER SCREEN.
2'
-
1
0
1
/
4
"
MI
N
.
O
F
F
S
E
T
(
T
Y
P
.
)
6"
3'
-
8
1
/
2
"
6"
MIN. OFFSET (TYP.)
6"2' - 2"6"
4'
-
8
1
/
2
"
M
I
N
.
B
L
O
C
K
I
N
G
(
V
I
F
)
3' - 2" MIN. BLOCKING (VIF)
DELL WYSE AND POWER
BRICK SECURED TO
MOUNTING BRACKET
DEVICE CAGE
MI
N
.
B
L
O
C
K
I
N
G
(
V
I
F
)
3'
-
1
1
/
4
"
(
9
2
0
M
M
)
(2
3
0
M
M
)
6"
CENTER OF MENU BOARDS AT
7' - 4" (2235MM) A.F.F. MIN.,
8' - 6" (2590MM) A.F.F. MAX.
SEE INTERIOR ELEVATIONS
FOR ACTUAL DIMENSION
3/4" PLYWOOD BACKING
BEHIND WALL FINISH,
SECURED TO STRUCTURE
METAL RECESSED CABLE
MANAGEMENT AND POWER
STORAGE BOX. MINIMUM (1)
RECEPTACLES AND (1) DATA
PORT PER SCREEN. MINIMUM
(4) OUTLETS AND (4) DATA
PORTS PER STORE.
CENTER OF MENU
ASSEMBLY
3' - 8 1/4"3' - 8 1/4"
4"4"4"4"6"6"4"4"
2' - 9"2' - 9"
MIN. OFFSET (TYP.)
6"WALL MOUNTED
MENU BOARD
BRACKET
DIGITAL SCREEN
EQ
EQ
EQ.11' - 0 1/2" (3364.2MM 3 SCREENS)EQ.
12' - 0 1/2" (3670.3 MM MIN. BLOCKING (VIF))
MI
N
.
O
F
F
S
E
T
(
T
Y
P
.
)
6"
MAX. LENGTH DATA (5'-6")
MAX. LENGTH POWER (5'-6")
r 5' - 6"
r 5' - 6"
EQ EQDUPLEX RECEPTACLE
FOR OPTIONAL
MICROWAVE AT 43"
A.F.F.
OPTIONAL
MICROWAVE ON
WOOD SHELF ABOVE
BACK WALL
EDGE OF
COUNTERTOP
CONVENIENCE DUPLEX
RECEPTACLE AT 43"
A.F.F.
1' - 2"
EDGE OF
SHELVING ABOVE
5'-7"
EQ EQ
COUNTERTOP
SUPPORT BELOW, TYP.
UNDERCOUNTER
REFRIGERATOR
PARTNER SINK
DUPLEX RECEPTACLE
RECEPTACLES AT 28" FOR
UNDERCOUNTER FRIDGE
RECEPTACLE FOR
REFRIGERATOR
AND/OR FREEZER
AT 84" (2135MM)
AFF
BACK WALL
RECEPTACLE FOR
SANITIZER AT 18"
(460MM) A.F.F.
BACK WALL
MOP SINK
WATER FILTRATION SYSTEM
(ABOVE)
GFCI 120V DUPLEX RECEPTACLE FOR
BOOSTER PUMP ABOVE INSTALLED AT
FACE OF WALL AT 8'-9" (2670MM) A.F.F.
(915MM)
3' - 3"
(75MM)
3"
GFCI 120V DUPLEX
RECEPTACLE FOR
WATER FILTRATION
SYSTEM AT 54"
(1370MM) A.F.F.
(305MM)
1' - 0"
GFCI 120V QUAD
RECEPTACLE FOR
WATER FILTRATION
SYSTEM AT 76"
(1930MM) A.F.F.
DUPLEX
RECEPTACLE FOR
INSTANT HOT
WATER TAP AT 26"
(660 MM) A.F.F.
(200 MM)
8"
(240 MM)
9 1/2"
DUPLEX
RECEPTACLE AND
DATA PORT AT 47"
(1190 MM) A.F.F.
SHELVING ABOVE
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
1
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I504
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ELECTRICAL DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"3ORDER STATUS BOARD INFRASTRUCTURE
3/4" = 1'-0"1DIGITAL MENU BOARDS - STANDARD MOUNT
3/4" = 1'-0"14PARTNER AMENITY STATION - ELECTRICAL
3/4" = 1'-0"11REFRIGERATOR/FREEZER - ELECTRICAL
3/4" = 1'-0"12SANITIZING WORKSTATION - ELECTRICAL
3/4" = 1'-0"13WATER FILTRATION - CONFIGURATION III
3/4" = 1'-0"16WATER FILLING STATION - ELECTRICAL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
.6" (152MM) MIN.
CLEAR TO BACK
WALL
ELEVATION - ELECTRICAL DIAGRAM
PLAN - ELECTRICAL DIAGRAM
ICE DIVERTER
VALVE
CONT. FRP ON BACK WALL
OFER IN WALL BLOCKING
BACK WALL
ICE BIN
ICE MACHINE
ICE HEAD ADAPTER
4' - 0"
2'
-
6
"
POWER RECEPTACLES FOR NUGGET
ICE AT 72" (1920MM) A.F.F.
ICE BIN
SENSOR CABLE
POWER CORD
ICE MACHINE
ICE HEAD ADAPTER
BIN TOP SENSOR DISTRIBUTION UNIT
ICE MANAGER CONTROL PANEL
ICE DIVERTER VALVE
ICE MANAGER
CONTROL PANEL
6"
6'
-
0
"
EQ EQ
POWER RECEPTACLES FOR
NUGGET ICE AT 72" (1920MM) A.F.F.
ACCESSIBLE CLEARANCE AT
CONTROL PANEL
BLOCKING PER MANUFACTURER'S
SPECIFICATIONS
1'
-
6
"
WW
POWER RECEPTACLE
AT 18" (457MM) TO
TOP OF RECEPTACLE
A.F.F.
RECEPTACLE FOR
WARMING WALL
POWER RECEPTACLE
AT 18" (457MM) TO
TOP OF RECEPTACLE
A.F.F.
EQ EQ
3' - 1 1/2"1' - 3"
7' - 6"
1/
2
"
QUAD RECEPTACLE
FOR GRINDER AND
FUTURE USE
DATA PORT FOR
FUTURE USE
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
DEDICATED
RECEPTACLE FOR
BREWER (14-50 NEMA
OUTLET)
DATA PORT FOR
FUTURE USE
POWER AND
DATA RECEPTACLE AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
2' - 0"
2"
5' - 9"
3' - 3 3/4"1' - 2"
(2) RECEPTACLES
FOR LABEL PRINTER
AND/OR CONNECT
DEVICE
2-DATA PORT FOR
LABEL PRINTER
AND/ OR CONNECT
DEVICE
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
UNDERCOUNTER
REFRIGERATOR
DEDICATED
RECEPTACLE FOR
ESPRESSO MACHINE
QUAD RECEPTACLE
FOR INSTANT HOT
WATER BOILER AND
UNDERCOUNTER
REFRIGERATOR
POWER
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
1"
3/4"
IoT
IoT MODULE FOR
ESPRESSO
MACHINE, FOIO
UNDERCOUNTER
WATER BOILER
FOR INSTANT HOT
WATER FONT
2
1' - 7"5' - 1"
9' - 0"
POWER AND DATA RECEPTACLES AT 28"
(711MM) TO TOP OF RECEPTACLE A.F.F.
4"
4"4"
RECEPTACLE FOR UNDERCOUNTER
REFRIGERATOR
QUAD RECEPTACLE FOR LABEL
PRINTER, FUTURE USE AND/OR
CONNECT DEVICES
2-DATA PORT FOR LABEL PRINTER
POWER AND DATA RECEPTACLES AT 28"
(711MM) TO TOP OF RECEPTACLE A.F.F.
UNDERCOUNTER REFRIGERATORUNDERCOUNTER REFRIGERATOR
22
RECEPTACLE FOR UNDERCOUNTER
REFRIGERATOR
(2) DEDICATED RECEPTACLE FOR
WARMING
2-DATA PORT FOR FUTURE USE
3' - 6 3/4"4' - 7 1/2"1' - 11 1/4"2' - 4 1/4"
12' - 5 3/4"
2' - 0"1' - 11"
UNDERCOUNTER REFRIGERATORS
IoT MODULE FOR ESPRESSO MACHINE,
FOIO (TYP. 1 OF 2)
POWER RECEPTACLES AT 28" (711MM) TO TOP OF RECEPTACLE A.F.F.
DEDICATED RECEPTACLE FOR ESPRESSO MACHINE
DEDICATED RECEPTACLE FOR INSTANT HOT WATER
BOILER
RECEPTACLE FOR UNDERCOUNTER REFRIGERATOR
AND FUTURE USE
POWER RECEPTACLES AT 28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
UNDERCOUNTER WATER BOILER FOR INSTANT HOT
WATER FONT (TYP. 1 OF 2)
2 2
POWER AND DATA RECEPTACLES AT 28" (711MM)
TO TOP OF RECEPTACLE A.F.F.
(2) RECEPTACLES FOR LABEL PRINTERS AND/OR
CONNECT DEVICES
2-DATA PORT FOR LABEL PRINTERS AND/OR
CONNECT DEVICES
2-DATA PORT FOR FUTURE USE
IoTIoT
DEDICATED RECEPTACLE FOR ESPRESSO MACHINE
DEDICATED RECEPTACLE FOR INSTANT HOT WATER
BOILER
RECEPTACLE FOR UNDERCOUNTER
REFRIGERATOR AND FUTURE USE
5' - 0"
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
DPM
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
2-DATA PORT FOR
DPM TABLET AND
SPARE
POWER AND
DATA RECEPTACLES
AT 28" (711MM) TO TOP
OF RECEPTACLE A.F.F.
2
6"
3' - 9"
1' - 0"
EDGE OF COUNTERTOP
BOX BASE (BELOW)
EDGE OF CABINET SHELVING (BELOW)UNDERCOUNTER SAFE
18" X 3" (457MM X 76MM) STUB-UP
PENETRATION AREA. SUPPLY POWER,
DATA AND PHONE CONDUITS FOR POS.
SEE BUILDING FLOOR PENETRATION
PLAN FOR FINAL LOCATION.
2 2
QUAD RECEPTICLE FOR FUTURE USE
2-DATA PORT FOR FUTURE USE
POWER RECEPTACLES AT 28" (711MM)
TO TOP OF RECEPTACLE A.F.F.
DEDICATED RECEPTACLE FOR
UPS (POS AND PED)
2-DATA PORT FOR POS, PED
AND/OR CONNECT DEVICES
POWER RECEPTACLES AT 28" (711MM)
TO TOP OF RECEPTACLE A.F.F.
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
2
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I504A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ELECTRICAL DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"1ELECTRICAL - NUGGET ICE3/4" = 1'-0"9WARMING WALL 1000 ELECTRICAL
3/4" = 1'-0"4BRW 09-01 ELECTRICAL
3/4" = 1'-0"14DTE 06-03 ELECTRICAL
3/4" = 1'-0"12DTW 06-02 ELECTRICAL
3/4" = 1'-0"11ESP 14-01 ELECTRICAL
3/4" = 1'-0"13MOP 07-04 ELECTRICAL3/4" = 1'-0"17POS 05-01 ELECTRICAL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
CEILING
ELEVATION - ELECTRICAL DIAGRAM
PLAN - UPPER ELECTRICAL DIAGRAM
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
SOFFIT
11' - 11"
1' - 4"2' - 4 1/2"
22 22 2
2' - 7 1/2"2' - 3 1/2"
11' - 11"
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
BLENDER(S)*
RECEPTACLE FOR
LABEL PRINTER
AND FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
2-DATA PORT FOR
FUTURE USE
*BLENDER
QUANTITY BASED
ON EQUIPMENT
SCHEDULE
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
UNDERCOUNTER
NITRO
REFRIGERATOR
RECEPTACLE FOR
UNDERCOUNTER
NITRO REFRIGERATOR
RECEPTACLE FOR
NITROGEN
GENERATOR
RECEPTACLE FOR
DPM TABLET
2-DATA PORT FOR
DPM TABLET AND
FUTURE USE
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
POWER RECEPTACLE
FOR RINSE SINK AT
28" (711MM) TO TOP
OF RECEPTACLE
A.F.F.
UNDERCOUNTER REFRIGERATOR
UNDERCOUNTERNITROGEN
GENERATOR
2
4' - 4 3/4"1' - 3 1/4"3' - 9 1/4"
RECEPTACLE FOR
MILK DISPENSER
RECEPTACLE FOR
ICE DISPENSER
RECEPTACLE FOR
LABEL PRINTER
AND FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
POWER AND DATA
RECEPTACLES AT 68"
(1727MM) TO TOP OF
RECEPTACLE A.F.F.
RECEPTACLE FOR
MILK DISPENSER
POWER AND DATA
RECEPTACLES AT 68"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
2'
-
4
"
6'
-
8
"
PLAN - ELECTRICAL DIAGRAM
POWER AND DATA
RECEPTACLES AT 80"
(2030MM) TO TOP OF
RECEPTACLE A.F.F.
PARTNER SIDE
POWER AND DATA RECEPTACLES
DEDICATED POS RECEPTACLE
2-DATA PORT FOR POS AND
FUTURE USE
(RELOCATE AS NECESSARY)
POWER AND DATA
STUB-UPS. SEE
BUILDING FLOOR
PENETRATION PLAN
FOR FINAL LOCATION.
POS BANK (TYP.)
CASH DRAWER (TYP.)
SAFE
POS MONITOR (TYP.)
NOTE:
FOR INFORMATION AND COORDINATION ONLY;
ENGINEER TO MODIFY AS APPROPRIATE
RECEIPT PRINTER (TYP.)
POWER AND DATA RECEPTACLES
DEDICATED RECEPTACLE FOR POS
QUAD RECEPTACLE FOR SAFE,
CUP LABELERS AND FUTURE USE
2-DATA PORT FOR POS
2-DATA PORT FOR CUP LABELER
(RELOCATE AS NECESSARY)
1' - 3"1' - 9"
6' - 6"
42
2
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER EXPEDITOR,
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA J-BOX
4-DATA J-BOX
POWER AND DATA RECEPTACLES
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT.
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA J-BOX
SINGLE DATA J-BOX
POWER AND DATA RECEPTACLES
QUAD RECEPTACLE
FOR UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER RECEPTACLE
UNDERCOUNTER
REFRIGERATOR
DUPLEX CONVENIENCE
POWER RECEPTACLE
EDGE OF COUNTERTOP
NOTE: EQUIPMENT SHOWN AS
DASHED LINES IS TO BE
FURNISHED AND INSTALLED BY
OWNER UNLESS NOTED
OTHERWISE
DRIVE THRU DIGITAL
PRODUCTION MONITOR
ELEVATION VIEW
DRIVE THRU TENDERING REGISTER
TRIPLE MONITOR MOUNT (GC INSTALLED)
SEE PLAN VIEW FOR MOUNTING LOCATION
POWER RECEPTACLES AT 28" (711MM) TO
TOP OF RECEPTACLE A.F.F.
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER, EXPEDITOR
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA PORT FOR TENDERING REGISTER
AND EXPEDITOR POS
4-DATA PORT FOR DT VIDEO, PED AND/OR
CONNECT DEVICES
POS BANK (TYP)
CASH DRAWERS
ELEVATION VIEW
DRIVE THRU VIDEO CONDUIT FROM DT ORDER POINT TO
DT VIDEO DATA BOX AT 28" (711MM) A.F.F.
DRIVE THRU EXPEDITOR POS
RECEIPT PRINTER
DT AUDIO CONDUIT FROM
DRIVE THRU ORDER POINT
AND DETECTOR LOOP
CONDUIT FROM DT
WINDOW TO DT TIMER
CONTROL DATA JUNCTION
BOXES AT 8'-2" (2490MM)
POWER RECEPTACLE AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
QUAD RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
SINGLE DOOR
REFRIGERATOR
DUPLEX CONVENIENCE
OUTLET AT 45" (1143MM) TO
TOP OF RECEPTACLE A.F.F.
*
5
"
* 1' - 11 1/2"
DIMENSIONS INDICATE CENTER
MOUNTING POINT FOR MONITOR BASE
*
DRIVE THRU WIRELESS HEADSET
BASE STATION
DRIVE THRU TIMER MONITOR
DRIVE THRU TIMER CONTROL UNIT
POWER AND DATA RECEPTACLES AT 8'-2" (2490MM)
TO TOP OF RECEPTACLES A.F.F.
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA PORT FOR DT TIMER AND CONTROL UNIT
SINGLE DATA PORT FOR DT AUDIO
(MIC & SPEAKER)
DRIVE THRU TIMER SIGNAL PROCESSOR (TSP)
36" W X 51" H (915MM W X 1295MM H) MIN. FIRE
RATED PLYWOOD BACKER BOARD. FASTEN TO
STRUCTURE. WALL FINISH TO CONCEAL.
FUTURE HHOP CABLING TO HEADSET BASE
STATION FROM J-BOX AT CLG/WALL FOR
EXTERNAL EXTENDED COVERAGE ANTENNA
(FOIO)
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
3
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I504B
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ELECTRICAL DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"1CBE 16-01 ELECTRICAL3/4" = 1'-0"13GENERIC DOUBLE POS ELECTRICAL & PLLUMBING DIAGRAM
3/4" = 1'-0"14DTP 03-02 ELECTRICAL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
PLAN VIEW
PRINTER
380MM
1' - 3"
4'
-
0
"
(
1
2
2
0
M
M
)
A
.
F
.
F
.
110MM
4 1/4"
25MM
1"
670MM
2' - 2 1/4"
2
1
SECURE KEY BOX
MUSIC SYSTEM PLAYER AND
AMPLIFIER (FURNISHED BY OWNER,
INSTALLED WITH SPEAKER SYSTEM
BY GC) ON 14" DEEP (355MM) SHELF
ONLY (MIN.) (NOT IN EQUIP. RACK).
CEILING HEIGHT SHOWN AT 96"
(2440MM). REFER TO
REFLECTED CEILING PLAN(S)
FOR ACTUAL HEIGHT.
WALL MOUNTED SHELVING
UNIT ATTACHED TO BACKER
BOARD
HOME PHONE
CONNECT (HPC)
CASH SCALE
ROLLING CART
IPOD TOUCH
CHARGING CRADLE
NOTE:EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED
AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE.
ROLLING CART
SHELVING ABOVE
DESK
SLEEVE FOR LOW VOLTAGE CABLE
BUNDLE MOUNTED TO (2) UNISTRUTS
POWER & DATA RECEPTACLES
(IN WALL, AT MUSIC SYSTEM SHELF)
(1) DUPLEX RECEPTACLE FOR:
MUSIC SYSTEM AMPLIFIER AND
FUTURE USE
(1) 2-DATA PORT FOR:
CURIO
POWER, TELEPHONE & DATA RECEPTACLES
(IN WALL, BELOW DESK)
(1) QUAD RECEPTACLE FOR:
PC, PRINTER, PHONE AND HPC
(1) QUAD RECEPTACLE FOR:
LAPTOP, CASH SCALE AND FUTURE USE
(1) QUAD RECEPTACLE
(1) PHONE MAIN
(1) 2-DATA PORT FOR:
PC AND PRINTER
A
LOW VOLTAGE
CABLE BUNDLE
1 MUSIC SYSTEM
PLAY NETWORK
SPEAKERS
2" (50MM) Ø SLEEVE FOR LOW
VOLTAGE CABLE BUNDLE
MOUNTED TO (2) UNISTRUTS
CEILING TRIM RING
60" W X 70" H (1525MM W X
1780MM H) MIN. 3/4" FIRE RATED
PLYWOOD BACKER BOARD.
FASTEN TO STRUCTURE TO
HOLD MIN. 350 PSF. PAINTABLE
SURFACE ON ROOM SIDE &
FINISH AS SCHEDULED.
POWER, TELEPHONE & DATA
RECEPTACLES AT 12" (305MM) A.F.F.
TO CENTER OF GROUPING. SEE
FLAN VIEW NOTE "A" ABOVE FOR
DESCRIPTION.
A
POWER & DATA RECEPTACLES
AT 60" (1525MM) A.F.F. TO
CENTER OF GROUPING. SEE
NOTE 'B' ABOVE FOR
DESCRIPTION.
DESK
OFFICE PC
LAPTOP
CORDLESS 1 LINE PHONE
ELEVATION VIEW
B
LOW VOLTAGE CABLE BUNDLES
SECURITY PANEL
FUTURE USE
- - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - -
2 SECURITY1 POS
HIGH SPEED INTERNET
DEMARC EXTENSION
POS LAN
DT TIMER
POWER & DATA RECEPTACLES
(IN WALL, ABOVE SHELVES)
(1) QUAD RECEPTACLE FOR:
EMS DATA CONCENTRATOR
(1) DUPLEX RECEPTACLE FOR:
SECURITY CONTROL ALARM PANEL
(1) 2-DATA PORT FOR:
EMS DATA CONCENTRATOR
B
(2) 2" (50 MM) Ø
SLEEVES FOR
LOW VOLTAGE
CABLE BUNDLES
MOUNTED TO
(2) UNISTRUTS
CEILING TRIM
RING (TYP.)
ENLARGED VIEW
SECURITY
CONTROL
ALARM PANEL
EMS DATA
CONCENTRATOR.
ALLOW 2" (50MM)
IN. CLEAR ABOVE
56" W X 42" H (1420MM W X 1065MM H) MIN. 3/4" FIRE RATED
PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE TO
HOLD MIN. 350 PSF. PAINTABLE SURFACE ON ROOM SIDE
AND FINISH AS SCHEDULED.
MINI GROUND BAR FOR EQUIPMENT RACK. GC TO
COORDINATE RACK GROUNDING TO BAR WITH #6 GROUND
WIRE AND PER JURISDICTIONAL REQUIREMENTS
POWER & DATA RECEPTACLES AT 87" (2210MM)
A.F.F. TO CENTER OF GROUPING. SEE PLAN VIEW
NOTE "A" ABOVE FOR DESCRIPTION.
610MM
2' - 0" CLEAR
EQUIPMENT RACK WALL MOUNTED TO STRUCTURE BY
STARBUCKS VENDOR (GC TO COORDINATE INSTALLATION).
GROUND RACK PER MFR'S ASSEMBLY INSTRUCTIONS. SEE
EQUIPMENT RACK SCHEDULE BELOW FOR EQUIPMENT
INCLUDED WITHIN.
PLAN VIEW
LAY-IN
CEILING
MOUNT GROUND BAR AT 116" (2945MM) A.F.F.
WIRELESS MODEM AT 92"
(2335MM) A.F.F. STARBUCKS
VENDOR TO DETERMINE
OPTIMAL DEVICE LOCATION
DEMARC, IF REQUIRED
POWER AND DATA
RECEPTACLES AT 104"
(2642MM) A.F.F. TO
CENTER OF GROUPING.
SEE NOTE 'B' ABOVE FOR
DESCRIPTION
UPS
IPS EQUIPMENT
ROUTER
EQUIPMENT RACK SCHEDULE
NETWORK SWITCH
PATCH PANEL
SECURITY RECORDER (NVR)
SECURITY KEYBOARD
PRODUCTION CONTROLLER DEVICES
SECURITY MONITOR
MOUNTED ON MONITOR
ARM (ATTACHED TO
BACKER BOARD).
NOTE:EQUIPMENT SHOWN AS DASHED
LINES IS TO BE FURNISHED AND
INSTALLED BY OWNER UNLESS
NOTED OTHERWISE.
ELEVATION VIEW
MOUNT EQUIPMENT RACK AT 84" (2133MM) A.F.F.
7'
-
0
"
EQ EQ
76" (1930MM)
CLEAR AREA
BELOW FOR
TRASH
CONTAINERS,
STORAGE OR
DELIVERY
DROP OFF
BACK OF HOUSE CEILING
HEIGHT PER PLAN
LAY-IN RAISED CEILING HEIGHT AT 120"
(3050MM) A.F.F. ABOVE TECH. EQUIPMENT
1 2
6"
6
"
15
0
M
M
.
15
0
M
M
.
..4"
100MM
1980MM
6' - 6" CLEAR
12
9
5
M
M
4'
-
3
"
.
940MM
3' - 1"
65MM
2' - 2 1/2"
370MM
1' - 2 1/2"
50
M
M
2"
MAINTAIN 24" (610MM) MIN.
CLEARANCE FOR WHEN
EQUIPMENT RACK IS IN
OPEN ACCESS POSITION (2) SLEEVES FOR
LOW VOLTAGE CABLE
BUNDLES MOUNTED
TO (2) UNISTRUTS
EQUIPMENT RACK
2
A POWER RECEPTACLES
(IN WALL, BEHIND OF EQUIPMENT RACK)
(1) INDIVIDUAL BRANCH CIRCUIT RECEPTACLE FOR:
UPS
(1) DUPLEX RECEPTACLE FOR:
PDU STRIP AND FUTURE USE
BULKHEAD WALL FOR
RECESSED CEILING
ABOVE EQUIPMENT
RACK
IOT GATEWAY
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
4
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I504C
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ELECTRICAL DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"13MANAGER DESK (NEW) - RIGHT- ELECTRICAL 3/4" = 1'-0"1EQUIPMENT RACK LEFT - ELECTRICAL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
NOTE:
FOR INFORMATION AND COORDINATION ONLY;
ENGINEER TO MODIFY AS APPROPRIATE
MASTRENA II
ESPRESSO MACHINE (TYP)
CUP LABELER (TYP)
DEDICATED RECEPTACLE FOR
ESPRESSO MACHINE
QUAD RECEPTACLE FOR INSTANT
HOT WATER TAP AND
UNDERCOUNTER REFRIGERATOR
POWER AND DATA RECEPTACLES
PARTNER SIDE
POWER AND DATA STUB-UPS.
SEE BUILDING PENETRATION PLAN
FOR FINAL LOCATION.
ESPRESSO PUMPS MOUNTED TO
SIDE OF CABINET ON BACKER
BOARD PER MANUFACTURER
SPECIFICATIONS
UNDERCOUNTER
REFRIGERATOR (TYP.)
(2) RECEPTACLES FOR CUP LABELERS
AND FUTURE USE
(2) 2-DATA PORTS FOR CUP LABELERS
AND FUTURE USE
POWER AND DATA RECEPTACLES
DEDICATED RECEPTACLE FOR
ESPRESSO MACHINE
QUAD RECEPTACLE FOR INSTANT
HOT WATER TAP AND
UNDERCOUNTER REFRIGERATOR
POWER AND DATA RECEPTACLES
PLUMBING STUB-UPS. SEE
BUILDING PENETRATION PLAN
FOR FINAL LOCATION.
PLUMBING FIXTURES FOR RINSER SINK (TYP.)
COLD FILTERED WATER SUPPLY FOR
HOT/COLD WATER DISPENSER FAUCET
COLD NON-FILTERED WATER SUPPLY
FOR PITCHER RINSER
COLD NON-FILTERED WATER SUPPLY FOR
METERED SPOON RINSER
ICE BIN
IoT
IoT MODULE FOR
ESPRESSO MACHINE, F010
IoT MODULE FOR
ESPRESSO MACHINE, FOIO
IoT
SNEEZE GUARD
6' - 6"
ELEVATION - ELECTRICAL DIAGRAM
22
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
LABEL PRINTER
AND FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
1' - 4"3' - 11"1' - 3"RECEPTACLE FOR
COMBI OVEN
2-DATA PORT COMBI
OVEN
POWER AND DATA
RECEPTACLES AT 18"
(457MM) TO TOP OF
RECEPTACLE A.F.F.
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
2'
-
4
"
1'
-
6
"
POWER AND DATA
RECEPTACLES AT 18"
(457MM) TO TOP OF
RECEPTACLE A.F.F.
ELEVATION - ELECTRICAL DIAGRAM
4"4"
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
4
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I504D
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
ELECTRICAL DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"1GENERIC ESPRESSO BAR ELECTRICAL & PLUMBING DIAGRAM
3/4" = 1'-0"2CBE 19-01 ELECTRICAL
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
CONFIGURATION III
WATER FILTRATION
SYSTEM. SEE
CONFIGURATION III, R.O.
AND SOFTENER DETAIL
FOR MORE
INFORMATION.
R.O. PERMEATE
TANK
FRP ENCLOSED
CL
E
A
R
6"
(
1
5
0
M
M
)
BA
C
K
E
R
4'
-
2
"
(
1
2
7
0
M
M
)
2'
-
6
"
(
7
6
5
M
M
)
7'
-
2
"
(
2
1
8
5
M
M
)
NOTE:
1. KEEP CLEAR AT BACKWALL FOR CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO
POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION
2'
-
0
"
(
6
1
0
M
M
)
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
STRAP UNITS PER LOCAL
CODE REQUIREMENTS
PROVIDE MOISTURE-
RESISTANT BLOCKING TO
STRUCTURE BEHIND
WALL FINISH AT THESE
AREAS. REFER TO ITEM
SPECIFICATIONS FOR
PLUMBING SCOPE;
COORDINATE INSTALL
WITH FILTER VENDOR.
FRP ENCLOSED
HOT WATER TANK. SEE
SPECIFICATIONS AND
WATER HEATER TANK
DETAIL FOR MORE
INFORMATION.
MOP HOLDER
3'
-
0
"
(
9
1
5
M
M
)
5'
-
0
"
(
1
5
2
5
M
M
)
HOSE CLIP
HOT AND COLD
WATER SUPPLY
FOR FAUCET
MOP SINK
SEE NOTE 1
BELOW
SEE NOTE 1
BELOW
2' - 0" (610MM)
6' - 0" (1830MM) MIN.
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
WATER BOOSTER PUMP
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FRP ENCLOSED
9'
-
6
"
(
2
8
9
5
M
M
)
T
O
B
O
T
T
O
M
O
F
B
L
E
N
D
E
D
S
T
O
R
A
G
E
T
A
N
K
SH
E
L
F
HOT WATER TANK (SEE
SPECIFICATIONS & HOT WATER
TANK DETAIL FOR FURTHER
INSTALLATION REQUIREMENTS)
1" (25MM)
BRASS CHECK
VALVE
EXPANSION TANK
STRAP UNITS PER LOCAL
REQUIREMENTS
HOT WATER TO DISHWASHER
(IF OTHER THAN HOBART
ADVANSYS UNIT), BAR SINKS,
MOP SINK AND COMPARTMENT
SINK.
1" (25MM) HOT WATER OUTLET
TEMPERED HOT WATER TO
HAND SINKS
TEMPERATURE MIXING
VALVES
UNION (TYP.)CONCEALED
COPPER PIPING (TYP.)
IF CONFIGURATION II
OR III, SOFTENED
COLD WATER TO
DISHWASHER
(IF HOBART
ADVANSYS UNIT).
SEE NOTE 2 BELOW.
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
PAN AND DRAIN LINE FOR
MAINTENANCE
BOOSTER PUMP.
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FL
O
W
DI
R
E
C
T
I
O
N
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS
DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4.. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED..
FLOW
DIRECTION
3/4" (20MM)
CHROME ESCUTCHEONS (TYP.)
3/4" (20MM)
BRASS THREADED BALL SHUT-OFF VALVE
(TYP.) MAX 72" (1830MM) A.F.F.
UNION (TYP.)
3/4" (20MM)
FILTERED COLD WATER
TO ICE MACHINE
POINT OF USE
FILTER LOCATED AT
ICE MACHINE
MOP SINK
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND FROM SOFTNER TO ADVANSYS DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SPECIFICATIONS).
5. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER EXCHANGE TANK SCHEMATIC.
6. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER.
R.O. PERMEATE
TANK
(180MM)
7"(235MM)
9 1/4"
GFCI 120V QUAD
RECEPTACLE FOR
FILTER SYSTEM 77"
(1955MM) A.F.F.
(SEE NOTE 3)FILTERED COLD WATER
TO FIXTURES (ESPRESSO
MACHINES, BREWERS,
HOT TAP, WATER TOWER
FAUCET)
75
"
(
7
9
0
5
M
M
)
OUT
R.O. CONTROL SYSTEM
(SEE NOTE 5)
3/4" (20MM)
SHUT-OFF
VALVE
3/4" (15MM)
FIP
3/4" (20MM) SHUT-OFF VALVE
3/4" (20MM) BYPASS
3/4" (20MM) SHUT-OFF
VALVE
CITY WATER IN
TO NON FILTERED
FIXTURES (TOILETS,
HAND SINKS, DIPPER
WELLS, BLENDER
PITCHER RINSERS,
IN-COUNTER RINSERS,
BAR SINKS, HOSE BIBBS)
3/4" (20MM) FIP
(FEMALE
INTERNATIONAL
PIPE THREAD
FITTING) (TYP. 1 OF
2 TO SOFTENER)
GFCI 120V
RECEPTACLE FOR
FILTER SYSTEM AT
54" (1372MM) A.F.F.
(SEE NOTE 3)
IN
BRINE TANK (FRONT)
WATER SOFTENER
HEAD AND TANKS
(BEHIND)
DRAIN LINE FROM
WATER HEATER
TANK PAN ABOVE
255MM)
11"
3" (75MM)
WATER
HEATER TANK
SEE WATER
HEATER TANK
DETAIL FOR
MORE
INORMATION
FROM WATER
HEATER TANK
TEMPERING
VALVE
OUT
IN IN
TO HOT WATER TANK
AND ADVANSYS
DISHWASHER
PLUMBING. SEE
WATER HEATER TANK
DETAIL FOR MORE
INORMATION
BYPASS VALVE
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
5'
-
0
"
(
1
5
2
5
M
M
)
TO R.O. SYSTEM
BOOSTER
PUMP
BYPASS
VALVE
3/4" (20MM)
CITY
WATER
IN
BOOSTER
PUMP
SHUT-OFF
VALVE
TO
BOOSTER
PUMP
3/4" (20MM)
BOOSTED
WATER IN
5'
-
9
"
(
1
7
5
0
M
M
)
WATER FILTRATION
BOOSTER PUMP.
SEE BOOSTER
PUMP DETAIL
FOR MORE
INFORMATION
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I505
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
PLUMBING DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
1/2" = 1'-0"1CONFIGURATION III
3/4" = 1'-0"3WATER HEATER TANK - PLUMBING
1" = 1'-0"9CONFIGURATION III, R.O. AND SOFTENER WATER FILTRATION
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
ABOVE COUNTER
ICE BIN (TYP. 1 OF 2)
NON-FILTERED COLD
WATER SUPPLY FOR
METERED SPOON RINSER
(TYP. 1 OF 2)
NON-FILTERED COLD
WATER SUPPLY FOR
PITCHER RINSER
(TYP. 1 OF 2))
RINSER SINK
(TYP. 1 OF 2)
2'
-
6
1
/
2
"
7' - 9 3/4"
UNDER COUNTER
12' - 7 1/4"
UNDERCOUNTER
REFRIGERATOR
(TYP. 1 OF 2)
ICE BIN ABOVE WITH
INDIRECT AND
INSULATED DRAIN
LINE TO NEAREST
FLOOR SINK
UNDERCOUNTER CABINET
UNDERCOUNTER
REFRIGERATOR
(TYP. 1 OF 2)
INDIRECT DRAIN LINE
FROM ESPRESSO
MACHINE TO FLOOR
SINK
INDIRECT DRAIN LINE FROM
RINSER SINK TO FLOOR SINK
FLOOR SINK (TYP. 1 OF 2)
SEE PLUMBING PLAN FOR
FINAL LOCATIONS AND
TYPE
ICE BIN ABOVE
WITH INDIRECT AND
INSULATED DRAIN
LINE TO FLOOR
SINK BELOW
COUNTERTOP SUPPORT
LEG (TYP. 1 OF 3)
UNDERCOUNTER BOILER
FOR INSTANT HOT WATER
FONT (TYP 1 OF 2)
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER FONT
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR UNDERCOUNTER
INSTANT HOT WATER BOILER
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER DISPENSER
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR ESPRESSO
MACHINES
**
UNDERCOUNTER
CABINET
PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND
FLEX HOSE CONNECTION*
**PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER
HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE
INDIRECT DRAIN LINE
FROM RINSER SINK TO
FLOOR SINK
INDIRECT DRAIN LINE FROM ESPRESSO
MACHINE TO NEAREST FLOOR SINK
1' - 2"
SEE PLUMBING
PLAN FOR FINAL
FLOOR SINK
LOCATION AND
TYPE
ICE BIN
ABOVE
INDIRECT DRAIN LINE
FROM ESPRESSO
MACHINE TO FLOOR
SINK
UNDERCOUNTER
REFRIGERATOR
INDIRECT DRAIN
LINE FROM
RINSER SINK TO
FLOOR SINK
UNDERCOUNTER
CABINET
INDIRECT AND
INSULATED DRAIN LINE
FROM ICE BIN ABOVE
TO FLOOR SINK
SUPPORT
LEG (TYP.)
2'
-
6
1
/
2
"
UNDER COUNTER
UNDERCOUNTER
REFRIGERATOR
NON-FILTERED COLD
WATER SUPPLY FOR
METERED SPOON RINSER
NON-FILTERED COLD
WATER SUPPLY FOR
PITCHER RINSER
ICE BIN
RINSER SINK
UNDERCOUNTER
CABINET
ABOVE COUNTER
5' - 9"
UNDERCOUNTER
BOILER FOR INSTANT
HOT WATER FONT
FILTERED COLD
WATER SUPPLY
FOR ESPRESSO
MACHINE
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER DISPENSER
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER FONT
*
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER BOILER
*
*
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO
SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
**PROVIDE BACKFLOW PREVENTION DEVICE
BEFORE PUMP AND WATER HAMMER ARRESTOR
PRIOR TO SHUT-OFF VALVE AND FLEX HOSE
CONT. INDIRECT AND
INSULATED DRAIN LINE
FROM ICE BIN AT SECOND
ESPRESSO BAR TO
FLOOR SINK HERE
CONT. INDIRECT DRAIN LINE
FROM ESPRESSO MACHINE
AT SECOND ESPRESSO BAR
TO FLOOR SINK HERE
HOT AND COLD WATER
FOR SINK FAUCET AT 20
1/2" (520MM) A.F.F. SHUT-
OFF VALVES AT WALL
AND 4" (100MM) EITHER
SIDE OF WASTE LINE.
FILTERED
COLD WATER
SUPPLY FOR
BREWER WITH
SHUT-OFF IN
CABINET AT
24" (610MM)
A.F.F.
7' - 6"
*
PROVIDE BACKFLOW PREVENTION DEVICE THEN
WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF
VALVE AND FLEX HOSE CONNECTION
*
FLOOR SINK
10"
F
L
O
O
R
S
I
N
K
2'
-
5
1
/
2
"
SEE PLUMBING PLAN FOR FINAL
FLOOR SINK LOCATION AND TYPE
INDIRECT DRAIN LINE FROM
RINSE SINK TO FLOOR SINK
INDIRECT
DRAIN LINE
FROM
BREWER TO
FLOOR SINK
DIRECT DRAIN LINE FROM
SINK. ROUGH-IN SINK
WASTE STUB AT 15 1/2"
(394MM) A.F.F. AND
CENTERLINE OF SINK
TEMPERED HOT AND COLD
WATER FOR SINK FAUCET
AT 20 1/2" (520MM) A.F.F.
SHUT-OFF VALVES AT WALL
AND 4" (102MM) EITHER
SIDE OF WASTE LINE.
7 1/2"
1' - 3"
6' - 6"
FLOOR SINK
ELEVATION - PLUMBING DIAGRAM
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER INJECTION
WITH SHUT-OFF IN
CABINET AT 18" (457MM)
A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER
INJECTION WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
INDIRECT DRAIN LINE
FROM COMBI OVEN TO
FLOOR SINK
SEE PLUMBING PLAN
FOR FINAL FLOOR SINK
LOCATION AND TYPE
PLAN - PLUMBING DIAGRAM
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
6
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I505A
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
PLUMBING DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"1ESP 14-01 PLUMBING3/4" = 1'-0"13DTE 06-03 PLUMBING
3/4" = 1'-0"11BRW 09-01 PLUMBING
3/4" = 1'-0"12ADD 02-01 PLUMBING
3/4" = 1'-0"3CBE 19-01 PLUMBING
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
DRAIN
SEE PLUMBING
PLAN FOR FINAL
FLOOR DRAIN
LOCATION AND
TYPE
.6" (152MM) MIN.
CLEAR TO BACK
WALL
INDIRECT DRAIN
LINE FROM ICE BIN
TO FLOOR DRAIN
INDIRECT DRAIN
LINE FROM ICE
DIVERTER TO
FLOOR DRAIN
ICE MACHINE
ICE TRANSPORT
TUBE BETWEEN ICE
MACHINE AND
DIVERTER VALVE.
MAX. LENGTH 10'
(3M)
ICE HEAD ADAPTER
ICE MANAGER
CONTROL PANEL
ICE TRANSPORT
TUBE LANE 2, TO
ICE BIN. MAX
LENGTH 75', MIN.
SLOPE 1/4":1'
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
3" PVC SLEEVE TO
SUPPORT ICE
TRANSPORT
TUBEFASTENED TO
WALL OR CEILING
W/ STRAPING @ 48"
O.C. MIN.
ICE DIVERTER
VALVE
ELEVATION - PLUMBING DIAGRAM
PLAN - PLUMBING DIAGRAM
CONT. FRP TO
CEILING ON BACK
WALL OVER IN
WALL BLOCKING
ICE BIN
ICE MACHINE
ICE HEAD ADAPTER
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
ECO-GRIP COVER
BASE
ACCESSIBLE
CLEARANCE AT
CONTROL PANEL
ICE MANAGER
CONTROL PANEL
ICE DIVERTER
VALVE
CONT. FRP ON
BACK WALL OVER
IN WALL BLOCKING
BACK WALL
MIN.
r 6"
BIN TOP SENSOR
DISTRIBUTION UNIT
ICE BIN
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
DRAIN
4' - 0"
2'
-
6
"
Plan View
KEEP CLEAR FOR WALL MOUNTED CHEMICAL DISPENSING SYSTEM, TO BE INSTALLED
BY SYSTEM VENDOR. PROVIDE BACKING BEHIND WALL FINISH FOR EQUIPMENT
MOUNTING. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION.
Elevation View
SOFTENED HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET
INDIRECT DRAIN LINE FROM DISHWASHER TO NEAREST FLOOR SINK.
BACK WALL
WATER FOR DISHWASHER WITH SHUT-OFF UNDER SINK AT 18" (460MM) AFF. LINE
LENGTH MUST ALLOW EASE OF MOVEMENT. VERIFY WATER REQUIREMENTS FOR
TYPE OF DISHWASHER (HOT/COLD/SOFTENED). SEE WATER SUPPLY DRAWINGS
FOR WATER LINE. IF ADVANSYS DISHWASHER, INCLUDE PRESSURE REDUCING
VALVE. PRESSURE GAUGE (SET TO 20 PSIG +/- 5 PSI), LINE STRAINER AND SHOCK
ARRESTOR.
DRAIN LINE FROM SINK TO FLOOR SINK BELOW
SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION. FLOOR DRAIN OPTIONAL.
WIRE RACK
COMPARTMENT SINK DISHWASHER
NOTE:
FOR COORDINATION ONLY. SEE FURNITURE, FIXTURES, AND EQUIPMENT PLAN
FOR EQUIPMENT LOCATIONS. PROVIDE BACKING BEHIND WALL FINISH AS
REQUIRED FOR WALL MOUNTED EQUIPMENT. REFER TO ITEM SPECIFICATIONS
FOR MORE INFORMATION.
PRE-WASH STATION
(1
3
7
0
M
M
)
4'
-
6
"
DRAIN LINE FROM DISHWARE DRYING RACKS TO SINK BOWL
DISHWARE DRYING RACKS WITH DRAIN LINE TO SINK BOWL
ALIGN
(1
1
9
5
M
M
)
3'
-
1
1
"
(9
6
5
M
M
)
3'
-
2
"
12' - 3"
3/4" PLYWOOD BACKER BOARD BEHIND WALL FINISH. FASTEN TO STRUCTURE
BEYOND.
B
MOP SINK AND WATER
FILTRATION EQUIPMENT.
SEE PLAN FOR ACTUAL
CONFIGURATION.
WATER HEATER TANK PER PLAN
ROOF STRUCTURE PER PLAN
SECTION B
CLEAR
3' - 6"
7'
-
2
"
(
M
I
N
.
T
O
B
O
T
O
M
O
F
S
H
E
L
F
)
BOTTOM OF WORKROOM
CEILING IN FOREGROND
OPEN TO WORKROOM
A
SECTION A
OPTIONAL VCT CEILING. HOLD
TIGHT TO STRUCTURE ABOVE
HOT WATER PIPING AND FLUE.
ENSURE ALL PENETRATIONS
THROUGH SURROUNDING
WALLS AND CEILING ARE
COMPLETELY SEALED.
CE
I
L
I
N
G
H
E
I
G
H
T
P
E
R
P
L
A
N
2"
BOOSTER PUMP
RECESSED CAN LIGHT
EQ EQEQEQ
HOT WATER TANK CHASE TO
ROOF STRUCTURE ABOVE.
PAINT GWB FINISH TO MATCH
BOH FRP.
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER FAUCET*
FILTERED
COLD WATER
SUPPLY FOR
INSTANT
HOT/COLD
WATER FONT
NON-FILTERED
HOT AND COLD
WATER SUPPLY
FOR SINK
FAUCET
ABOVE COUNTERTOP
AT FLOOR LEVEL
INDIRECT LINE
FROM PREP
SINK ABOVE TO
FLOOR SINK
SHELVING
ABOVE
FILTERED COLD
WATER SUPPLY FOR
UNDERCOUNTER
INSTANT HOT
WATER BOILER
(LOCATION MAY
VARY)
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO
SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I505B
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
PLUMBING DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"13PLUMBING - NUGGET ICE - PEDESTAL STACK 3/4" = 1'-0"1SANITIZING (GENERIC) - PLUMBING
1/2" = 1'-0"3WATER HEATER TANK CHASE3/4" = 1'-0"11WATER FILLING STATION - PLUMBING
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
IN-WALL INDIRECT
DRAIN LINE FROM
ICE DISPENSER TO
FLOOR DRAIN
OUTLET BOX FOR
INDIRECT DRAIN
LINE
FLOOR DRAIN
SOFFIT
OUTLET BOX FOR
INDIRECT DRAIN
LINE
FLOOR DRAIN
OUTLET BOX FOR
INDIRECT DRAIN
LINE
1'
-
1
"
4'
-
1
1
1
/
2
"
CEILING
OUTLET BOX FOR
INDIRECT DRAIN
LINE
ICE TRANSPORT TUBE
LANE 1, TO ICE
DISPENSER. MAX
LENGTH 75', MIN. SLOPE
1/4":1'.
CONTINUOUS CONDUIT
FASTENED W/ STRAPING
@ 48" O.C. MIN.
CEILING
IN-WALL INDIRECT
DRAIN LINE FROM
ICE DISPENSER TO
FLOOR DRAIN
SOFFIT
11' - 11"
INDIRECT LINE FROM
DRAINBOARD TO FLOOR
SINK
HOT AND NON-FILTERED COLD
WATER FOR SINK FAUCET AT
20 1/2" (20MM) A.F.F. SHUT-OFF
VALVES AT WALL AND 4" (100MM)
EITHER SIDE OF WASTE LINE
NON-FILTERED COLD WATER SUPPLY
FOR BLENDER PITCHER RINSER
INDIRECT DRAIN LINE FROM SINK
TO FLOOR SINK
FILTERED COLD WATER
SUPPLY FOR WATER TOWER
FAUCET
DRAIN LINES FROM
DRAIN TRAY AND
UNDERCOUNTER
REFRIGERATOR;
SEPARATE,
INDIRECT
TERMINATION AT
FLOOR SINK
SEE PLUMBING PLAN FOR FINAL
FLOOR SINK LOCATION AND TYPE
ELEVATION - PLUMBING DIAGRAM SECTION A - PLUMBING DIAGRAM
ACCESS
PANEL/DOOR
DOOR FACE W/
TAPERED EDGE
PULL
MOUNTING
TEMPLATE, BLACK
IN-WALL BLOCKING
REQUIRED,
PROVIDED BY G.C.
FRAMING, BLACK
ACCESS DOOR
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
CONTINUOUS CONDUIT
FASTENED W/ STRAPING
@ 48" O.C. MIN.
A
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
2
7
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I505C
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
PLUMBING DETAILS
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
3/4" = 1'-0"1CBE 15-01 PLUMBING
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
1/
3
/
2
0
2
4
8
:
5
0
:
1
1
P
M
C:
\
U
s
e
r
s
\
b
s
a
u
n
\
H
e
s
t
i
a
A
t
e
l
i
e
r
D
r
o
p
b
o
x
\
P
r
o
j
e
c
t
s
\
S
t
a
r
bu
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
-
10
0
0
5
.
r
v
t
I601
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
FF&E SCHEDULES
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
/
2
/
2
0
2
4
SPECIALTY EQUIPMENT SCHEDULE - "E"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
COOLING
10267 2 FRIDGE UNDERCOUNTER 1 DOOR - 27IN 685MM SB MANUF: DELFIELD, MODEL:
400P-STAR2
12618 1 FRIDGE UNDERCOUNTER 1 DOOR WITH SHELF -
27IN 685MM
SB MANUF: DELFIELD, MODEL:
400P-STAR4
13676 1 FREEZER REACH IN 1 DOOR RH - 27IN 685MM SB MANUF: TRUE FOOD SERVICE INC.,
MODEL: T-23F-HC-RH STAR
EQUIPMENT
17564 1 BLENDER PITCHER RINSER WITH SENSOR SB MANUF: VITAMIX, MODEL: 61304
19742 1 ESPRESSO MACHINE MASTRENA II SB MANUF: THERMOPLAN, MODEL:
19742
22885 1 BREWER CLOVER VERTICA DOUBLE SB MANUF: DONLIM, MODEL: CM9700
23380 1 BREWER CLOVER VERTICA INSTALL KIT SB MANUF: DONLIM, MODEL: NEMA
14-50
23381 1 BREWER CLOVER VERTICA CORD SB MANUF: PENTAIR, MODEL:
EV9910-00
23419 3 MILK DISPENSER SB MANUF: DONLIM, MODEL: RE100
23442 1 OVEN COMBI SB MANUF: CONVOTHERM, MODEL:
MINI ET 10.10
23454 1 BOH PARTNER AREA MICROWAVE OVEN - BLACK GC MANUF: PANASONIC, MODEL:
347990
FOOD CASE
16239 1 FOOD CASE - ZEPHYR MINI - 54IN 1370MM SB MANUF: OASIS, MODEL:
SBZ5452DR
23444 1 FOOD CASE - WARMING WALL - 1000 SQUARE SB MANUF: FLEXESERVE, MODEL:
FXZNA10S4S-SF61
ICE
10102 2 ICE - BIN B55 SB MANUF: ICE-O-MATIC, MODEL:
B55PS
19278 3 ICE - BIN DROP IN 45LB 20KG HORIZONTAL SB MANUF: ELKAY, MODEL: CUSTOM
ICE BIN
23181 2 ICE - MACHINE HMD2110RBT REMOTE COOLED SB MANUF: HORIZON ELITE, MODEL:
HMD2110RBT
23337 2 ICE -BIN ADAPTOR FOLLETT B55H22H30
PEDESTAL TOP FOR B55
SB MANUF: HORIZON ELITE, MODEL:
B55H22H30
23421 1 ICE - NUGGET ICE DISPENSER MANUF: FOLLETT, MODEL: ID50
23422 1 ICE - NUGGET ICE DISPENSER RIDE MANUF: FOLLETT, MODEL:
23423 1 ICE - NUGGET ICE DIVERTER MANUF: FOLLETT, MODEL:
23424 1 ICE - NUGGET ICE DIVERTER CONTROL PANEL MANUF: FOLLETT, MODEL:
IMDV-2CM
OTHER
10091 1 CUP DISPENSER TALL HOT VERTICAL SB MANUF: DISPENSE-RITE, MODEL:
ECL-NS-A34P
10099 2 RESTROOM TOILET PAPER HOLDER SB MANUF: ASI, MODEL: 0030
10172 2 RESTROOM SEAT COVER DISPENSER SB MANUF: GAMCO, MODEL: TSC-1
10396 1 CUP DISPENSER SHORT HOT VERTICAL SB MANUF: DISPENSE-RITE, MODEL:
ECL-NS-299P
10791 2 CUP DISPENSER GRANDE VENTI COLD VERTICAL SB MANUF: DISPENSE-RITE, MODEL:
ECL-NS-845P
10855 2 CUP DISPENSER GRANDE VENTI HOT VERTICAL SB MANUF: DISPENSE-RITE, MODEL:
ECL-NS-31P
10858 1 CUP DISPENSER TALL COLD VERTICAL SB MANUF: DISPENSE-RITE, MODEL:
ECL-NS-422P
10859 2 RESTROOM GRAB BAR - 48IN 1220MM SB MANUF: ASI, MODEL: 3400
10862 2 RESTROOM GRAB BAR - 36IN 915MM SB MANUF: ASI, MODEL: 3400
10947 1 SOAP DISPENSER WALL MOUNTED SB MANUF: GAMCI, MODEL: G-58AP
10977 1 PAPER TOWEL DISPENSER FULL SIZE SB MANUF: GEORGIA PACIFIC, MODEL:
56650A
10992 2 PAPER TOWEL DISPENSER HALF SIZE -
TRANSLUCENT GRAY
GC MANUF: GEORGIA PACIFIC, MODEL:
56640
11115 4 SOAP DISPENSER SINK MOUNTED SB MANUF: GAMCO, MODEL: G-64LB
13330 1 MOBILE CUP DISPENSER CADDY SB MANUF: SPG, MODEL:
STBKCCAD8BLK
13584 1 CUP DISPENSER TRENTA COLD VERTICAL SB MANUF: DISPENSE-RITE, MODEL:
ECL-NS-69P
22627 1 NITRO 2 TAP HANDLE WITH BADGE AND MOUNT
KIT
SB MANUF: JOE TAP, MODEL: 22627
23420 2 REFRESHER DISPENSE SMALL SB MANUF: WOODMAX, MODEL:
WK054
STORAGE
10222 1 WIRE SHELF GRID AT SINK SB MANUF: SPG, MODEL: STBKWT2Y
10416 1 WORKROOM SHELVING - 36IN 915MM SB MANUF: SPG, MODEL: WST966
10462 1 WORKROOM SHELVING POSTS SB MANUF: SPG, MODEL: STBKP86Z4
10698 1 MOP RACK WITH 3 HOLDERS SB MANUF: GAMCO, MODEL: MS-1A
13578 1 DISHWARE DRYING RACK - 21IN 535MM SB MANUF: SPG, MODEL: WMRS-21-KD
22212 1 WORKROOM SHELVING CART KIT SB MANUF: SPG, MODEL: WST1878C
23445 3 PASTRY COOLING RACK WALL MOUNTED SB
PLUMBING FIXTURE SCHEDULE - "P"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
DRAIN
10594 2 DRAIN - FLOOR DRAIN SQUARE - 5IN 125MM GC MANUF: SMITH, MODEL: P035
X10726 9 DRAIN - GRATE HALF SQUARE - 12IN 305MM GC MANUF: ZURN, MODEL: Z1855
FAUCET
10152 2 FAUCET - DOUBLE LABORATORY WITH BENT
RISER SPOUT
SB MANUF: ZURN, MODEL: Z826S1-XL
10153 4 FAUCET - WATER TOWER - 12IN 305MM SB MANUF: CHG, MODEL: KL26-5012-SP
10215 1 FAUCET - DOUBLE LABORATORY WITH SWING
SPOUT
SB MANUF: ZURN, MODEL: Z826F1-XL
10447 1 FAUCET - PRE RINSE SPRAYER WALL
MOUNTED
SB MANUF: ENCORE, MODEL: KL53-1000-BLF
10597 2 FAUCET - SINGLE HANDLE SB MANUF: ZURN, MODEL: Z7440-XL
10804 1 FAUCET - PRE RINSE SWING SPOUT SB MANUF: ENCORE, MODEL: KL55-7012-SE4
10922 1 FAUCET - MOP SINK WALL MOUNTED SB MANUF: ZURN, MODEL: Z843M1
11003 3 FAUCET - METERED SB MANUF: CHICAGO FAUCETS, MODEL:
333-665PSHABCP
13588 1 FAUCET - HAND SINK WALL MOUNTED SB MANUF: ENCORE, MODEL; KL45-4000-SC4
21352 2 FAUCET - RESTROOM WITH MOTION SENSOR SB MANUF: ZURN, MODEL: Z6955-XL-S
22642 3 FAUCET - INSTANTHOT SYSTEM 2 BUTTON
WITH BOILER AND BRACKET
SB MANUF: MARCO, MODEL: MIX UC3 HOT/
AMBIENT. KIT INCLUDES FONT,
UNDERCOUNTER BOILER AND BOILER
BRACKET FOR SIDE PANEL MOUNTING.
BRACKET CAN BE FLOOR MOUNTED
USING SET OF (4) STAINLESS STEEL
LEGS, ORDERED SEPARATELY THROUGH
VENDOR.
FILTER
23355 1 FILTER - FILTRATION BOOSTER PUMP VD
OTHER
21669 1 GREASE INTERCEPTOR GB75 GC MANUF: SCHIER, MODEL: GB-75
X0022 1 GREASE SAMPLE PORT - SV10 GC MANUF: SCHIER, MODEL: SV-10
X0044 2 WALL HYDRANT GC LOCALLY SOURCED BY GC
SINK
10116 2 SINK - RESTROOM WALL MOUNTED SB MANUF: KOHLER, MODEL: K-2005
10549 2 SINK - RINSE DROP IN SST - 12X20IN
305X510MM
SB MANUF: ELKAY, MODEL: P393
10995 1 SINK - MOP - 24X24IN 610X610MM SB MANUF: ZURN, MODEL: Z1996-24
13700 1 SINK - 3 COMP WORK SST - 105IN 2665MM VD MANUF: ELKAY, MODEL: 3C18X20-L20-R26
14688 1 SINK - HAND WITH SIDE SPLASH WALL
MOUNTED SST
SB MANUF: ENCORE, MODEL: FS17D-1410-05
17565 1 SINK - RINSE WITH DRAINBOARD - 15X27IN
380X685MM
SB MANUF: ELKAY, MODEL: 11232015
22768 3 SINK - COUNTERTOP RINSER WITH WATER
TOWER - 26X9IN 660X235MM
SB MANUF: ELKAY, MODEL: OSB216773X
TOILET
22558 2 TOILET - TANKLESS AUTOMATIC SINGLE
FLUSH
GC WC TO BE PURCHASED THROUGH
FERGUSON:
NA.PROJECTS@FERGUSON.COM
DATA DEVICE SCHEDULE - "A"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
AUDIO VISUAL
10015 5 SPEAKER RECESSED - WHITE VD
DATA
20294 1 IOT MODULE SB
GRAPHICS - INTERIOR MENU
22970 4 MENU BOARD - DIGITAL DISPLAY - 44X25.25IN
1121X644MM - BLACK
SB
22972 1 MENU BOARD - DIGITAL MENU BOARD MOUNTING
BRACKET THREE SCREEN - BLACK
SB
23021 1 MENU BOARD - ORDER STATUS BOARD
MOUNTING BRACKET - BLACK
VD
LIGHTING FIXTURE SCHEDULE - "L"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS
PENDANT
20794 2 PENDANT - ROLL AND HILL HALF AND HALF
CONE - BLACK
VD AS PACKAGED: 1X
LED A19 7W E26 BASE
RECESSED CAN
21772 42 CAN - LED ADJUSTABLE RECESSED - 3IN
75MM - WHITE - 800LM FLOOD
VD INTEGRATED LED
21774 5 CAN - LED ADJUSTABLE RECESSED - 3IN
75MM - WHITE - 700LM WF
VD INTEGRATED LED
21776 11 CAN - LED WALL WASH - 3IN 75MM - WHITE -
1000LM
VD INTEGRATED LED
SCONCE
20748 2 SCONCE - KUZCO PLUTO TRIPLE - CHROME VD INTEGRATED LED
STRIP
22216 1 STRIP - LED TAPE IN HOUSING - VARIABLE
LENGTH - WHITE - 350LM PER FT
VD INTEGRATED LED FIELD TRIMMABLE TO
0.9IN LENGTHS
22217 3 STRIP - LED TAPE - VARIABLE LENGTH -
350LM PER FT
VD INTEGRATED LED FIELD TRIMMABLE TO
0.9IN LENGTHS
22251 2 STRIP - LED TAPE IN HOUSING - VARIABLE
LENGTH - WHITE - 800LM PER FT
VD INTEGRATED LED FIELD TRIMMABLE TO
1.97IN LENGTHS
TROFFER
21783 7 TROFFER - LED RECESSED - 24X48IN
600X1200MM - WHITE - 4300LM
VD INTEGRATED LED
MECHANICAL EQUIPMENT SCHEDULE - "M"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
X5002 4 TITUS - 4 FT LINEAR DIFFUSER GC
X5050 1 The Standard series, a commercial and industrial
hybrid, is our most popular energy-saving series. It
features a ½ horsepower power motor(s) that is louder
and stronger than the LoPro but is ideal for a multitude
of customer-facing and industrial applications. It is
also available in ETL Sanitation Certified versions and
is suitable for heights up to 10 ft (ETL Sanitation rated
for 7 ft heights.) The standard color on all models is
Obsidian Black and heated options are available.
GC MANUF: MARS, MODEL: STD2 72
HVAC
10925 4 HVAC - RETURN HARD LID SQUARE - 24IN 610MM GC
11163 2 HVAC - RETURN LAY IN SQUARE - 24IN 610MM GC
SITE SCHEDULE - "Y"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
OTHER
23113 1 GROUND GRAPHICS DT ENTRY STENCIL VD REFERENCE PAINT 20511 FOR SPECIFICATIONS
23115 1 GROUND GRAPHICS DO NOT ENTER STENCIL VD REFERENCE PAINT 20511 FOR SPECIFICATIONS
EXTERIOR SIGNAGE SCHEDULE - "S"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY BULB COMMENTS
SIGNAGE - DISK
13164 1 SIGN - DISK SF ILLUMINATED FLUSH
MOUNTED EVOLVED - 60IN 1525MM
VD
SIGNAGE - DRIVE THRU
22544 1 SIGN - DT CLEARANCE BAR SQUARE FRAME
FREESTANDING - BLACK AND DARK GREEN
VD
23071 1 SIGN - DIRECTIONAL EXIT ONLY ILLUM DS -
EXG FOUNDATION - 44IN 1120MM
VD
23077 1 SIGN - DT DIRECTIONAL ARROW ILLUM DS -
EXG FOUNDATION - 44IN 1120MM
VD
SIGNAGE - OTHER
X21297 4 PEDESTRIAN CROSSING CAUTION SIGN VD
FURNITURE SCHEDULE - "F"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
CHAIR
21359 5 CHAIR - CAFE PEGGY - WHITE OAK WD0073 SB
TK0077 1 CHAIR - MANAGERS WORKSTATION SB STEELCASE SERIES ONE ARMLESS
DESK
TK0053 1 DESK - MANAGERS WORKSTATION SHELVES -
48IN 1220MM
SB
TK0076 1 DESK - MANAGERS WORKSTATION - 48X24X27IN
1220X610X685MM
SB
MIRROR
10093 2 MIRROR - RESTROOM - 18X30IN 455X760MM GC
OTHER
10756 2 COAT HOOK 1 PRONG SQUARE - 2IN 50MM - SST SB
STORAGE
TK0078 1 FILE MOBILE PEDESTAL WITH CUSHION AND
LOCK
SB
TK0079 1 MANAGERS DESK CART - 24X20IN 610X510MM SB
TABLE
21449 2 TABLE - BASE CAFE HEIGHT BOTTLE - FLAT
BLACK MT0028
SB
21453 1 TABLE - BASE ACCESSIBLE BOTTLE - FLAT BLACK
MT0028
SB
21474 1 TABLE - BASE ACCESSIBLE POST LEG
RECTANGULAR - FLAT BLACK MT0028
VD
21788 1 TABLE - TOP ACCESSIBLE FOR POST LEG
RECTANGULAR - 40X24IN 1015X610MM - WHITE
OAK WD0073
VD
21803 1 TABLE - TOP ACCESSIBLE ROUND EDGE
RECTANGULAR - 40X24IN 1015X610MM - WHITE
OAK WD0073
VD
21848 2 TABLE - TOP ROUND EDGE SQUARE - 24IN 610MM
- WHITE OAK WD0073
SB
21979 1 TABLE - OCCASIONAL SIDE WING - WHITE OAK
WD0073
VD
WINDOW TREATMENT
22488 6 ROLLER SHADE - WHITE - 5PC OPEN VD
GRAPHICS AND ARTWORK SCHEDULE - "G"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
GRAPHICS - ARTWORK
16979 1 ART - MICHAEL HANSON - COLOMBIA 14 - BW VD GLAZED ARTWORK WITH 1/2"W X 1
1/2"D WOOD FRAME - WD0073 -
OVERALL DIMS: 44"W X 29 1/4"H
16991 1 ART - MICHAEL HANSON - COLOMBIA 20 - BW VD GLAZED ARTWORK WITH 1/2"W X 1
1/2"D WOOD FRAME - WD0073 -
OVERALL DIMS: 44"W X 29 1/4"H
16997 1 ART - MICHAEL HANSON - COLOMBIA 23 - BW VD GLAZED ARTWORK WITH 1/2"W X 1
1/2"D WOOD FRAME - WD0073 -
OVERALL DIMS: 44"W X 29 1/4"H
23229 1 ART - FOX SPEARS – KENYA MOUNTAINS VD GLAZED ARTWORK WITH 1/2"W X 1
1/2"D WOOD FRAME - WD0073 -
OVERALL DIMS: 60"W X 45"H
X0013 1 PARTNER RECOGNITION BOARD VD PARTNER RECOGNITION BOARD
W/ 2" X 1/2" WOOD FRAME -
WD0073. OVERALL DIMENSIONS :
45" W X 46 1/2" H - ARTWORK DID:
22063
GRAPHICS - OTHER
10427 2 RESTROOM SIGN SET UNISEX ACCESSIBLE
CALIFORNIA - BLACK
SB
23136 1 AUTOMATIC DOOR CAUTION SIGNAGE VD
X12693 1 CUSTOM COMMUNITY BOARD - 3'8" X 2'5" -
WD0073
VD CUSTOM COMMUNITY BOARD W/ 1"
WOOD FRAME - WD0073. OVERALL
DIMENSIONS : 44" W X 29" H
Revision Schedule
Rev Date By Description
B 1/2/24 MG City/County 1st round comments
B
B
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
DOOR LEGEND
STOREFRONT
METAL FRAME
DOUBLE
(TYPE A)
SINGLE
IMPACT
DOUBLE
ACTING
SINGLE
FLUSH
EXTERIORINTERIORINTERIOR
WINDOW LEGEND
DRIVE-THRU
WINDOW
OPENING NOT TO
EXCEED 432 SQ. IN.
STATE OF CALIF RNIA
O
REN.09/30/25
S
LICEN
D ARCHITECT
E
H
I
DENO R I I WAGAM
I
C-34970
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
11
/
3
/
2
0
2
3
2
:
0
6
:
3
5
P
M
W:
\
P
r
o
j
e
c
t
s
\
S
t
a
r
b
u
c
k
s
\
B
r
i
s
t
o
l
&
W
a
r
n
e
r
1
0
0
0
5
\
C
D
\
B
r
i
st
o
l
&
W
a
r
n
e
r
-
1
0
0
0
5
.
r
v
t
I602
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
HESTIA ATELIER
TAMEEM H
ISCOLINA D
CASEWORK & FINISHES
SCHEDULES
CH
E
C
K
S
E
T
1
0
-
3
0
-
2
0
2
3
CEILING TREATMENT SCHEDULE - "U"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
MISCELLANEOUS
11302 551 SF ACT VlNYL - 2' X 4' GC MFR: ARMSTRONG, MODEL: CLEAN ROOM VL870
X11302 336 SF RETAIL AREA ACT - 2'X4' GC MFR: ARMSTRONG, MODEL: CIRRUS
SECONDLOOK: 514
FLOOR TREATMENT SCHEDULE - "T"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
PLASTIC
19795 988 SF POLYVINYL FLOOR TILE - ECO-GRIP -
PEWTER
GC GC TO PROCURE FROM ALLIED
INDUSTRIES
TILE
20251 612 SF TILE - ECOCRETE - AQUA - HONED - 24X24IN
600X600MM
VD GROUT: MAPEI - 11 SAHARA BEIGE, OR
EQUAL
WALK OFF MAT
19289 24 SF WALK OFF MAT - HELIX Z2 - BLACK AND
GUNMETAL - 12X9IN 305X230MM
VD CANNOT BE CUT TO SIZE; USE HELIX Z1
AS BORDER WHEN FULL TILES CANNOT
BE PLACED
WALL BASE SCHEDULE - "B"
DESIGN ID LENGTH DESCRIPTION FURN. BY INST. BY COMMENTS
TILE BASE
15116 158' - 7" TILE BASE - ECOCRETE - AQUA - 6X12IN
150X300MM
VD GROUT: MAPEI - 02 PEWTER, OR EQUAL
X19795 306' - 2
1/4"
ECOGRIP 6" BASE GC POLYVINYL ECOGRIP FLOORING TO WRAP UP 6"
ON WALLS AND CABINETS WITH 3/8" COVE RADIUS
AND HEAT WELDED SEAMS
X19798 5' - 8" ECOGRIP 10" BASE - AT MOP SINK GC POLYVINYL ECOGRIP FLOORING TO WRAP UP 10"
ON CURB AND CABINETS WITH 3/8" COVE RADIUS
AND HEAT WELDED SEAMS
WALL TREATMENT (AREA) SCHEDULE - "Q"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
PLASTIC
11469 1779 SF FRP - WHITE GC
TILE
20242 252 SF TILE - COLOR STUDIO - WHITE - 6X24IN
150X600MM
VD GROUT: MAPEI - 47 CHARCOAL, OR EQUAL
20244 268 SF TILE - COLOR STUDIO - MALT - 6X24IN
150X600MM
VD GROUT: MAPEI - 111 HICKORY, OR EQUAL
WALL COVERING
20623 261 SF WALL COVERING - BURLAP - RETREAT VD
WALL TREATMENT (LENGTH) SCHEDULE- "R"
DESIGN ID LENGTH DESCRIPTION FURN. BY INST. BY COMMENTS
X10368 50' - 2" WOOD PANELING - WD0073 MAD200-V CW See Casework Finish Schedule for Material
WINDOW FILM SCHEDULE "Z"
DESIGN ID AREA DESCRIPTION FURN. BY INST. BY COMMENTS
19459 184 SF WINDOW FILM - FASARA - MILKY CRYSTAL VD
X1999 72 SF WINDOW FILM - OMBREA VD
PAINT SCHEDULE
DESIGN ID DESCRIPTION LRV FURN. BY INST. BY COMMENTS
SW6071 SW6071 POPULAR GRAY, OR EQUIVALENT 61 GC USE SEMI-GLOSS (SG) AT BACKBAR &
RESTROOM AREAS/WET AREAS - USE
EGG-SHELL (ES) FOR ALL NON-WET AREAS
SW9169 SW9169 CHATURA GRAY, OR EQUIVALENT 30 GC USE SEMI-GLOSS (SG) AT BACKBAR &
RESTROOM AREAS/WET AREAS - USE
EGG-SHELL (ES) FOR ALL NON-WET AREAS
CASEWORK FINISH SCHEDULE
ENGINE ZONE MATERIAL DESCRIPTION FINISH CODE COMMENTS
COMPOSITE - WILLOW
COUNTERTOPS - BACKBAR COMPOSITE - WILLOW CPX066
COUNTERTOPS - FRONTBAR COMPOSITE - WILLOW CPX066
METAL - FLAT BLACK POWDERCOAT
CABINETS - DOOR PULL METAL - FLAT BLACK POWDERCOAT MT0028
CABINETS - UNDERCOUNTER
ICE BIN
METAL - FLAT BLACK POWDERCOAT MT0028
FRAMING AND HARDWARE METAL - FLAT BLACK POWDERCOAT MT0028
METAL - STAINLESS STEEL - BRUSHED
CABINETS - CABINET LEG METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
CABINETS - UNDERCOUNTER
ICE BIN
METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
COUNTERTOPS - BACKBAR METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
COUNTERTOPS - ESPRESSO METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
COUNTERTOPS - HAND SINK METAL - STAINLESS STEEL - BRUSHED #4 BRUSHED
16GA
PLAM - GOLDEN BLONDE GRAIN
CABINETS - EXTERIOR PLAM - GOLDEN BLONDE GRAIN PL0027
CABINETS - UNDERCOUNTER PLAM - GOLDEN BLONDE GRAIN PL0027
CABINETS - UPPER PLAM - GOLDEN BLONDE GRAIN PL0027
WOOD - WHITE OAK - ROUNDED SLAT - VERTICAL
FINISH PANELS - FRONTBAR WOOD - WHITE OAK - ROUNDED SLAT -
VERTICAL
WD0073
MAD200-V
CASEWORK SCHEDULE - "C"
DESIGN ID COUNT DESCRIPTION FURN. BY INST. BY COMMENTS
X0017 1 DRIVE-THRU UPPER CABINET - ALT 3 CW
X2003 1 STAINLESS CUP LABELER SST MOVABLE RISER CW
X3020 1 1 1/2" CORIAN - WILLOW CW
X3030 4 1 1/2" X 1" WOOD TRIM - WD0073 CW
X3040 2 1 1/2" X 1 1/2" WOOD TRIM - WD0073 CW
X3060 1 PARTNER REST AREA - UPPER CUBBIES - PL0027 CW
BANQUETTE
23009 1 BANQUETTE - WALLFLOWER - VARIABLE LENGTH - WHITE OAK
WD0073
CW
TK0065 1 BANQUETTE - WALLFLOWER OUTSIDE CORNER VERTICAL
STITCH - WHITE OAK WD0073 - CARAMEL BROWN NATURAL
F-0008
CW
CABINET
17573 5 CABINET - BACKBAR COUNTER SUPPORT PANEL - 3IN 75MM CW
17574 3 CABINET - BACKBAR SINK OR ICE - 15IN 380MM CW
17740 2 CABINET - BACKBAR - 30IN 760MM CW
17741 6 CABINET - BACKBAR 15IN 380MM CW
17743 1 CABINET - DT POS - 30IN 760MM CW
17744 1 CABINET - FRONTBAR POS BRIDGE - 22IN 560MM CW
17745 3 CABINET - BACKBAR DRAWER - 15IN 380MM CW
17747 7 CABINET - BACKBAR TRASH - 15IN 380MM CW
17896 1 CABINET - BACKBAR CUBBY - 15IN 380MM CW
18122 1 CABINET - BACKBAR SINK OR ICE - 16IN 405MM CW
19281 1 CABINET - ESPRESSO ICE BIN STAINLESS - 20IN 510MM CW
19281 2 CABINET - ICE BIN STAINLESS - 20IN 510MM CW
19343 1 CABINET - CORNER FIT KIT CW
21189 1 CABINET - FRONTBAR - 12IN 380MM CW
21189 1 CABINET - FRONTBAR - 15IN 380MM CW
21190 1 CABINET - FRONTBAR TRASH - 15IN 380MM CW
21191 1 CABINET - FRONTBAR DRAWER - 15IN 380MM CW
21946 1 CABINET - FRONTBAR POS - 23IN 585MM CW
23385 1 CABINET - BOTTOM SHELF - 9IN 230MM CW
23388 1 CABINET - BACKBAR - 18IN 460MM CW
23391 1 CABINET - CBE ICE DISPENSE BRACKET CW
23393 3 CABINET - CBE MILK DISPENSE BRACKET SLIDE CW
23426 1 CABINET - WRM LOW - 30IN 760MM CW
SSxxxxx 1 CABINET - CBE ICE DISPENSE DOOR - 24IN 610MM CW
SSxxxxx 2 CABINET - CBE MILK DISPENSE DOOR - 10IN 255MM CW
SSxxxxx 1 CABINET - CBE MILK DISPENSE DOOR - 11IN 280MM CW
CAFE
20131 1 CONDIMENT WASTE AND RECYCLING CART THREE DROP -
WHITE OAK AND WHITE WD0073 CP0002
CW
20390 1 FREESTANDING INLINE 3 UNIT SHORT - 90IN 2285MM - WHITE
OAK WD0073
VD
COUNTERTOP
10020 1 DT WINDOW SHELF - 48IN 1205MM - CP0002 VD
17807 3 COUNTERTOP - BACKBAR - 15IN 380MM CW
17809 2 COUNTERTOP - HAND SINK WITH LOW SPLASH STAINLESS -
15IN 380MM
CW
17826 1 COUNTERTOP - DT POS - LF - 78IN 1980MM CW
18720 1 COUNTERTOP - BREW WITH TRASH DROP - LF - 90IN 2285MM CW
18871 1 COUNTERTOP - FRONTBAR - 18IN 455MM CW
18886 1 COUNTERTOP - END CAP SQUARED - LF CW
19338 1 COUNTERTOP - DT STAINLESS ESPRESSO METRO - RF -
VARIABLE LENGTH
CW
20271 1 COUNTERTOP - FRONTBAR MOP PLANAR - 60IN 1525MM CW
21948 1 COUNTERTOP - POS - LF - 45IN 1145MM CW
21960 1 COUNTERTOP - DT WARMING - RF - 108IN 2745MM CW
23146 1 COUNTERTOP - CBE RINSE SINK 90LB ICE BINS - RF - 152IN
3860MM
CW
23411 1 COUNTERTOP - CBE IN-LINE RF - 138IN 3505MM CW
23433 1 COUNTERTOP - WRM RF - 79IN 1930MM CW
X19282 1 COUNTERTOP - STAINLESS ESPRESSO METRO - 154IN CW
DIEWALL
18859 1 DIEWALL - 45IN 1145MM CW
18865 1 DIEWALL - 60IN 1525MM CW
18884 1 DIEWALL - END CAP - RF CW
18887 4 DIEWALL - END CAP - LF CW
23412 1 DIEWALL - FRAMING UPPER - VARIABLE LENGTH CW
23413 4 DIEWALL - SUPPORT ARM UPPER CW
FIT KIT
17894 1 FIT KIT - CABINET FILLER PANEL CW
OTHER
11142 1 CORBEL SUPPORT - 24IN 610MM CW
11155 3 ESPRESSO MACHINE PUMP MOUNT - 10X10IN 255X255MM CW
18145 4 COUNTERTOP SUPPORT LEG CW
20633 2 COUNTERTOP SUPPORT LEG SLIM CW
X00001 1 IMPULSE FIXTURE CW
PANEL
18717 1 PANEL - 60IN 1525MM CW
18860 1 PANEL - 45IN 1145MM CW
18873 1 PANEL - 18IN 455MM CW
18888 1 PANEL - END CAP - LF CW
23415 1 PANEL - CBE FRONT PANEL UPPER IN-LINE CW
SSxxxxx 2 CABINET - CBE UPPER SIDE PANEL CW
SSxxxxx 2 PANEL - CBE INTERIOR PANEL UPPER CW
DOOR SCHEDULE - "D"
DESIGN ID MARK DESCRIPTION WIDTH HEIGHT HARDWARE SET Finish FURN BY INST BY COMMENTS
23132 a DOOR - BARRIER FREE HARDWARE ACTUATOR MULLION MOUNT (none) VD
23131 c DOOR - BARRIER FREE HARDWARE ACTUATOR WALL MOUNT (none) VD
23129 b DOOR - BARRIER FREE HARDWARE KEY SWITCH (none)VD
23134 19 DOOR - BARRIER FREE HARDWARE OPERATOR - SILVER (none) VD
4
Exterior
10449 16 DOOR - STOREFRONT METAL FRAME DOUBLE - TYPE A 6' - 0" 7' - 0" 3-A CLEAR GC
1
Interior
10190 05 DOOR - SINGLE FLUSH - 36IN 3' - 0" 7' - 0" 6 SW-WHITE
(SEMI-GLOSS)
PAINT
GC
10190 15 DOOR - SINGLE FLUSH - 36IN 3' - 0" 7' - 0" 6 WD0073 GC
10086 14 DOOR - SINGLE IMPACT DOUBLE ACTING - 36IN 915MM 3' - 0" 7' - 0" 11 PL0027 GC
3
1 Stops and Holders 473 Door Stop w/ Hook Rockwood 626
3 Accessories GJ64 Rubber Silencer Glynn Johnson Gray
2 Protective Trim Units K1050 B4E Kickplate 8" x 34" Each Side 32D Rockwood 630
1 Closing Devices 8916 Door Closer 8916 AF89P Dorma 689
1 Securing Devices PB5425LN Lock, Shallow Coin Turn,
Privacy PB5425LN-693-497 1-3/4 Yale Lock 626
3 Hanging Items TA2714/MPB79 Hinge MacPro Bearing 5 x 4.5 McKinney 626
No. Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 6 - For restroom door with lever and privacy lock
1 Traffic Door Package SCP8 36" x 84" Eliason As Selected
No. Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 11 - For workroom door at backbar
1 Sign Vinyl Sign: "THIS DOOR MUST REMAIN
UNLOCKED WHEN BUILDING IS OCCUPIED"Seton ---
1 Threshold 325 Half Saddle Threshold National Guard ---
2 Accessories Door Sweep 18062CNB36 Pemko A
2 Stops and Holders 473 Door Stop w/Hook Rockwood 626
2 Closing Devices 8916 Door Closer 8916 AF89P AL Dorma 689
2 Operating Trim 48 Push Bar x 31 Rockwood 630
2 Operating Trim 108 Door Pull Handle Rockwood 630
2 Securing Devices (active leaf) A08794-003 Adjustable Ring, Mortise Cyl. 5/16-13/32 Falcon Lock 626
2 Securing Devices (active leaf) C987 7-Pin Mortise Cylinder Housing w/AR Cam Falcon Lock 626
9 Securing Devices (active leaf) KB632-2 Cut User Key "A" Keyway Falcon Lock ---
1 Securing Devices (active leaf) KB609-2 Cut Control Key "A" Keyway Falcon Lock ---
2 Securing Devices (active leaf) C607 7-Pin Core Combinated "A" Keyway Falcon Lock 626
1 Securing Devices (inactive
leaf)MS1880 Two-Point Flushbolt Adams Rite 626
1 Securing Devices (active leaf) MS1850S Deadbolt Adams RIte 626
6 Hanging Devices TA2314/MPB91 Hinge MacPro Bearing 4.5 x 4.5 McKinney 630
No. Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 3-A - For pair aluminum main entry/exit doors (300 or less occupancy)
WINDOW SCHEDULE
DESIGN ID COUNT DESCRIPTION FINISH FURN. BY INST. BY COMMENTS
WINDOW
21987 1 WINDOW - DT BI-PARTING RESTRICTED OPENING - 54X52IN - WITH AIR CURTAIN & TRANSOM CLEAR GC MANUF: READY ACESS, MODEL: WC14X29131
1 Stop & Holders 473 Door Stop w/ Hook Rockwood 626
3 Accessories GJ64 Rubber Silencer Glynn Johnson Gray
2 Protective Trim Units K1050 B4E Kickplate 8" x 34" Each Side 32D Rockwood 630
1 Closing Devices 8916 Door Closer 8916 F89P Dorma 626
1 Securing Devices C607 7-Pin Core Combination "A" Keyway Falcon Lock 626
1 Alarm Lock CO-100 Privacy Keypad Schlage 626
3 Hanging Devices TA2714/MPB79 Hinge MacPro Bearing 5 x 4.5 McKinney 626
No. Item Description Manufacturer Finish
DOOR HARDWARE SET NO. 7-A - For restroom door with cipher lock
Revision Schedule
Rev Date By Description
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E001
ELECTRICAL
NOTES
SECURITY SYSTEM NOTES
A.STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY AND
INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF
SECURITY SYSTEM FOR FOUR (4) TIMES;
1.MEET TO PLAN SECURITY CABLE PULL WITH SECURITY CABLE INSTALLER
PRIOR TO DRYWALL INSTALLATION.
2.SECURITY CABLE INSTALLER PULLS SECURITY CABLES, MOUNTS PANEL,
KEYPAD AND SENSORS.
3.SECURITY EQUIPMENT INSTALL OF CAMERA, NVR AND MONITOR.
4.SECURITY MONITORING COMPANY TO BRING SYSTEM ONLINE AND TRAIN
PARTNERS AFTER POS INSTALL
B.SECURITY VENDOR REQUIRES A MINIMUM TWO (2) WEEKS LEAD TIME FOR EACH
INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL
ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO
SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
TELEPHONE SYSTEM NOTES
A.IF ADDITIONAL TELEPHONE LINES ARE REQUIRED BEYOND THE STANDARD SINGLE
LINE (SUCH AS FOR A FIRE ALARM) THE GENERAL CONTRACTOR SHALL CONTACT
STARBUCKS PRIOR TO BEGINNING CONSTRUCTION TO ORDER THE ADDITIONAL
TELEPHONE LINE(S). REPORT ANY TELEPHONE INSTALLATION ISSUES IMMEDIATELY
TO STARBUCKS.
B.CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THERE ARE EXISTING,
WORKING TEL FACILITIES TO THE BUILDING OR THAT LANDLORD HAS FURNISHED
AND INSTALLED ONE (1) 2" (51MM) MIN. (ENTRANCE) CONDUIT INCLUDING PULL
STRING FROM TELCO STREET FEED LINE TO THE BUILDING AS IDENTIFIED BY THE
PHONE COMPANY. NOTIFY STARBUCKS CONSTRUCTION MANAGER IMMEDIATELY IF
FACILITIES OR CONDUIT AND PULL STRING ARE NOT INSTALLED.
C.GENERAL CONTRACTOR IS TO ENSURE THAT THERE IS A 2" (51MM) MIN. CONDUIT
WITH PULL STRING FROM THE DATA RACK TO THE DEMARC (TELCO TO CUSTOMER
HAND OFF EQUIPMENT) WHEN THE DEMARC IS MORE THAN 10' FROM THE DATA
RACK. DISTANCES LESS THAN 10' WILL NOT REQUIRE CONDUIT.
D.ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE TELEPHONE/
NETWORK CABLING VENDOR.
POS/ DATA LINE NOTES
A.STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY
AND INSTALL CATEGORY 5e (CAT5e) LAN CABLE AND CONNECTORS FOR THE POINT
OF SALE (POS) SYSTEMS. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA
CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD
TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL
INSTALLERS.
B.AT THE START OF CONSTRUCTION, STARBUCKS CONSTRUCTION MANAGER
SCHEDULES DELIVER OF CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT
AND INSTALLATION BY A POS INSTALL TECHNICIAN FOR ONE (1) MONTH PRIOR TO
STORE OPEN. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO (2) WEEKS PRIOR
TO DELIVERY AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE
STORE. CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY. DO NOT REFUSE
DELIVERY.
C.DATA CABLING TECHNICIAN TO PROVIDE ALL CAT5e LAN CABLING AND
CONNECTORS FROM ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS,
MANAGER'S WORKSTATION, ALL OTHER NETWORKED EQUIPMENT (CUP LABELERS,
CLOVER, BUMP BAR, ETC...) AND WIRELESS ACCESS POINT TO THE DATA RACK
AREA. CONTRACTOR IS TO HAVE CONDUIT WITH PULL STRING IN PLACE FOR ALL
CABLE RUNS PRIOR TO CABLE INSTALL DATE.
D.STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING STARBUCKS
POS SYSTEMS DELIVERY AND INSTALLATION WITH THE POS VENDOR. THIS GROUP
MAY BE CONTACTED AT: NEWSTORES@STARBUCKS.COM.
COMMUNICATION SYSTEM NOTES
A.CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT THE LANDLORD HAS
FURNISHED AND INSTALLED ONE (1) ADDITIONAL 2" (51MM) (ENTRANCE) CONDUIT
INCLUDING PULL STRING (FOR A TOTAL OF TWO (2)) FROM THE STREET FEED TO
THE BUILDING AS IDENTIFIED BY THE INTERNET SERVICE PROVIDER.
FIRE ALARM SYSTEM NOTES
A.IF STARBUCKS IS REQUIRED TO PROVIDE A FIRE ALARM AND/OR FIRE ALARM
MONITORING AND/OR PHONE LINES FOR A FIRE ALARM, AS SPECIFIED IN THE LEASE
AGREEMENT, THE CONTRACTOR IS TO NOTIFY GNOC IMMEDIATELY THAT FIRE
ALARM LINES ARE NEEDED. STARBUCKS PREFERRED FIRE ALARM SERVICE
PROVIDER, STANLEY, IS TO BE CONTACTED BY THE CONSTRUCTION MANAGER TO
INSTALL FIRE ALARM PANEL AND/OR MONITORING SERVICE AS REQUIRED.
WIRELESS NETWORK NOTES
A.CABLING FOR INTERNET SERVICE SHALL BE FURNISHED AND INSTALLED BY THE
VENDOR FOR FIBER OR BROADBAND CONNECTIONS. T1 AND ETHERNET EXTENSION
CABLING IS PROVIDED BY THE STARBUCKS (TELEPHONE/ NETWORK) CABLING
VENDOR. COORDINATE WITH STARBUCKS.
MUSIC SYSTEM NOTES
A.PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS.
CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM.
MOUNT OWNER FURNISHED SPEAKERS WHERE SHOWN ON INTERIOR
REFLECTED CEILING PLAN AND IN COORDINATION WITH ALL PLANS AND
DETAILS. FOLLOW MANUFACTURER'S INSTALLATION REQUIREMENTS.
CONTROLS AND OPERATION
A.COORDINATE INSTALLATION OF LIGHTING CONTROL PANEL (IF APPLICABLE)
AND ENERGY MANAGEMENT SYSTEM (EMS) WITH ENERGY MANAGEMENT
SYSTEM VENDOR.
B.FURNISH AND INSTALL RACEWAYS WITH PULLSTRINGS AND JUNCTION BOXES
TO SUPPORT VENDOR’S WORK.
C.COORDINATE WITH VENDOR AND PLANS FOR DEVICE LOCATIONS.
GENERAL ELECTRICAL NOTES
A.THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK AND
SPECIFICATIONS WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND
SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT
SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING
DIMENSIONS. OVERALL CASEWORK COMPONENT DIMENSIONING ON ELECTRICAL
DETAILS ARE SHOWN FOR REFERENCE AND COORDINATION ONLY. SEE
SPECIFICATION SHEETS FOR ELECTRICAL SPECIFICATIONS.
B.ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE
ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM WITHIN 10%
OF THE HIGHEST PHASE LOAD IN EACH PANEL BOARD.
C.THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DE-ENERGIZING
CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL
DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT
WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT
CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED.
D.THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM
OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN
ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN
11:00PM AND 5:00AM.
E.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY CONDUIT
AND J-BOXES TO SUPPORT A COMPLETE SECURITY, PHONE, POS AND DATA
SYSTEMS. SEE MANAGER WORKSTATION AND BAR POINT OF SALE (POS)
POWER/TELECOM/SECURITY DIAGRAM. COORDINATE ALL DEVICE LOCATIONS AND
MOUNTING HEIGHTS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. PROVIDE
END-TO-END PULL STRINGS IN ALL CONDUITS. LABEL EACH END OF THE PULL
STRING WITH CONDUIT SYSTEM ("SECURITY") AND DESTINATION ("CAFÉ", "FRONT
BAR", ETC.). PROVIDE INSULATED BUSHINGS ON ALL STUBBED-UP AND EXPOSED
CONDUIT ENDS.
F.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR
TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS, CEILINGS OR OTHER
SURFACES IDENTIFIED TO REMAIN THAT MAY BECOME DAMAGED DURING THE
COURSE OF WORK.
G.EXPOSED/SURFACE MOUNTED CONDUITS SHALL ONLY BE ALLOWED WHERE
NECESSARY IN EXPOSED CEILING AREAS. IF CONDUITS NEED TO BE SURFACE
MOUNTED TO WALLS, COORDINATE WITH STARBUCKS CONSTRUCTION MANAGER
FOR APPROVAL.
H.VERIFY LOCATION OF ALL OUTLETS AND SWITCHES WITH ARCHITECTURAL
DRAWINGS, INTERIOR DETAILS, FINISH SCHEDULES, GENERAL CONTRACTOR,
EQUIPMENT VENDORS, STARBUCKS AND EXISTING SITE CONDITIONS. VERIFY FINAL
DOOR HINGE LOCATION PRIOR TO SWITCH INSTALLATION AND ADJUST SWITCH
LOCATION IF NEEDED. DO NOT MOUNT RECEPTACLES/SWITCHES IN LOCATIONS
THAT WOULD CONFLICT WITH MIRRORS, SEAMS OF WALLS, WAINSCOTS, TILE
TRANSITIONS, ETC.
GENERAL NOTES
SCOPE
THE INTENT OF THE SPECIFICATION AND THE DRAWINGS IS TO PROVIDE A
COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL
CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL, AND
EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK.
SITE EXAMINATION
THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS
WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL
REPORT ANY CONDITION THAT, IN HIS OPINION, PREVENTS THE PROPER
INSTALLATION OF THE ELECTRICAL WORK.
STANDARDS
EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE
PROVISIONS OF CSA, ULC, NEC, ASTM, UL, ETL, NEMA, ANSI, AS APPLICABLE
TO EACH INDIVIDUAL UNIT OR ASSEMBLY.
CODES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL
APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE OF
CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE CODES,
THE HIGHEST STANDARD SHALL APPLY. ELECTRICAL CONTRACTOR SHALL
SATISFY CODE REQUIREMENTS AS A MINIMUM STANDARD WITHOUT ANY
EXTRA COST TO STARBUCKS.
PERMITS AND FEES
THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS,
FEES, AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK.
WARRANTY
THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL
WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A
PERIOD OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY
STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK
PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING
WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND
WORKMANSHIP.
STANDARD ABBREVIATIONS
AFF
AHJ
APPROX
ABOVE FINISHED FLOOR
AUTHORITIES HAVING JURISDICTION
APPROXIMATE
BLDG BUILDING
CKT
CLG
CM
CONST
CW
CXA
CIRCUIT
CEILING
STARBUCKS CONSTRUCTION MANAGER
CONSTRUCTION
COLD WATER
COMMISSIONING AGENT
DEG
DL
DM
DN
DTL
DWG(S)
DEGREES
LIGHTS WITHIN DAYLIGHT ZONE
STARBUCKS DESIGN MANAGER
DOWN
DETAIL
DRAWING(S)
EA
EC
ECP
EG
ELEC
EM
EMS
EXIST
EXT
EACH
ELECTRICAL CONTRACTOR
EQUIPMENT CONTROL PAC
EXHAUST GRILLE
ELECTRICAL
EMERGENCY
ENERGY MANAGEMENT SYSTEM
EXISTING
EXTERIOR
F&I
FLR
FT
FURNISH & INSTALL
FLOOR
FOOT/FEET
GC
GFCI
GND
GENERAL CONTRACTOR
GROUND FAULT CIRCUIT INTERRUPTER
GROUND
HR
HVAC
HW
HOUR
HEATING, VENTILATION, AIR CONDITIONING
HOT WATER
LCP
LL
LS
LV
LIGHTING CONTROL PANEL
LANDLORD
LIGHT SENSOR PHOTOCELL
LOW VOLTAGE
MAX
MC
MDP
MECH
MEP
MFG
MIN
MAXIMUM
MECHANICAL CONTRACTOR
MAIN DISTRIBUTION PANEL
MECHANICAL
MECHANICAL, ELECTRICAL, AND PLUMBING
MANUFACTURER
MINIMUM
NL
NTS
NIGHTLIGHT
NOT TO SCALE
OCP OVERCURRENT PROTECTION
REF
REQ(’D)
REV
REFERENCE
REQUIRE(D)
REVISION
SF
SHT
SPECS
SST
SQUARE FEET
SHEET
SPECIFICATION(S)
STAINLESS STEEL
TEL
TEMP
TYP
TELEPHONE
TEMPORARY
TYPICAL
UNO UNLESS NOTED OTHERWISE
WH
WP
WATER HEATER
WEATHER PROOF
ELECTRICAL SYMBOL LEGEND
SYMBOL DESCRIPTION
POWER
DUPLEX RECEPTACLE, WALL MOUNTED
DUPLEX RECEPTACLE, WALL MOUNTED, SPLIT-WIRED OCCUPANCY SENSOR
CONTROLLED/SWITCHED
DUPLEX RECEPTACLE, WALL MOUNTED, ISOLATED GROUND
DUPLEX RECEPTACLE, WALL MOUNTED ABOVE COUNTER
DUPLEX GFCI RECEPTACLE, WALL MOUNTED
DUPLEX GFCI RECEPTACLE, WALL MOUNTED ABOVE COUNTER
DUPLEX RECEPTACLE, WALL MOUNTED WITH TWO 5V USB CHARGING PORTS
DOUBLE DUPLEX RECEPTACLE, WALL MOUNTED
DOUBLE DUPLEX GFCI RECEPTACLE, WALL MOUNTED
DUPLEX RECEPTACLE, FLUSH IN CEILING
SPECIAL OUTLET: 20A, 250V, 2P, 3-WIRE NEMA 6-20R
SPECIAL OUTLET: 30A, 125V, 1P, 3-WIRE NEMA 5-30R
SPECIAL OUTLET: 30A, 250V, 2P, 3-WIRE NEMA 6-30R
SPECIAL OUTLET: 50A, 250V, 2P, 3-WIRE NEMA 6-50R
SPECIAL OUTLET: 50A, 250V, 3P, 4-WIRE NEMA 14-50R
JUNCTION BOX
JUNCTION BOX - WALL MOUNTED
JUNCTION BOX MOUNTED IN ACCESSIBLE CEILING SPACE. MOUNT FLUSH IN FLOOR WHEN
INDICATED IN A FLOOR BOX SYMBOL.
NON-FUSED DISCONNECT SWITCH
FUSED DISCONNECT SWITCH
MOTOR. NUMBER INDICATES HORSEPOWER RATING FOR 1HP AND LARGER
MOTOR. "F" INDICATES FRACTIONAL HORSEPOWER
TRACK CURRENT LIMITER. "#" DENOTES AMPS RATING.
POWER SUPPLY/DRIVER, CLASS 2 FOR LED
FLOOR BOX SPECIFICATIONS
SINGLE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN.
WIREMOLD RFB2-OG/FPCTC WHEN SHOWN IN ON-GRADE
WIRE MOLD 6ATCP, 6ATP, OR 6ATCPAV AS REQUIRED WHEN SHOWN IN ABOVE GRADE.
TWO SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN.
WIREMOLD RFB2-OG/FPCTC WHEN SHOWN IN ON-GRADE
WIRE MOLD 6ATCP, 6ATP, OR 6ATCPAV AS REQUIRED WHEN SHOWN IN ABOVE GRADE.
SIGNAL
TELEPHONE OUTLET
DATA OUTLET
COMBINATION TELEPHONE/COMPUTER OUTLET
LIGHTING CONTROL SYMBOLS
SINGLE POLE SWITCH, 20A, 120/277V or CAT5e WIRED WALL SWITCH TO BE USED WITH
NON-DIMMING POWER/RELAY PACK
LOW VOLTAGE (0-10V) WALL MOUNTED SWITCH FOR MANUAL ON/OFF AND DIMMING
(STEPPED/CONTINUOUS) CONTROL OF LIGHTING. "a" INDICATES ZONE WHERE SHOWN ON
DRAWINGS.
OCCUPANCY SENSOR - WALL MOUNTED. "a" INDICATES CONTROLLED ZONE. SEE CONTROL
CONFIGURATIONS FOR MORE INFORMATION.
OCCUPANCY SENSOR w/ DIMMER - WALL MOUNTED. "a" INDICATES CONTROLLED ZONE.
SEE CONTROL CONFIGURATIONS FOR MORE INFORMATION.
1-WAY/2-WAY DIRECTIONAL CEILING MOUNTED, NON-NETWORKED/ INTERCONNECTED/
NETWORKED, SYSTEM-BASED OCCUPANCY SENSOR. QUANTITY OF ADJACENT LOWER CASE
LETTERS INDICATES QUANTITY OF RELAYS/DIMMING CIRCUITS REQUIRED - SEE CONTROL
CONFIGURATIONS BELOW FOR MORE INFORMATION. EXACT CONTROL FUNCTION IS DETERMINED
BY THE BALLAST/FIXTURE TYPE.
AUTOMATIC CONTINUOUS DIMMING DAYLIGHTING CONTROLLER USED TO DIM LIGHTS WHEN
SUFFICIENT NATURAL LIGHT IS PRESENT. NUMBER IN PARENTHESIS INDICATES THE AVERAGE
WORKPLANE "TARGET ILLUMINATION" SYMBOL VALUE. ADJACENT LOWER CASE LETTER(S)
INDICATES SWITCH LEG(S) CONTROLLED. ADJACENT "+, ++ AND *" INDICATES PORTION OF SWITCH
LEG CONTROLLED BY SENSOR WHERE "+" INDICATES PRIMARY SIDELIT DAYLIT ZONE, "++"
INDICATES SECONDARY SIDELIT DAYLIT ZONE, AND "*" INDICATES SKYLIT DAYLIT ZONE.
CONTROL CONFIGURATIONS
y "y" INDICATES THAT SWITCH LEG "y" TO BE CONFIGURED IN A "AUTO ON 100% / AUTO OFF" AND BE
CONTROLLED (CONTINUOUSLY DIMMED) BY THE ASSOCIATED CEILING SENSOR REMOTE SWITCH
ON THE WALL.
y,(y)"y,(y)" INDICATES THAT SWITCH LEG "y" TO BE CONFIGURED IN A "AUTO ON 50% / MANUAL ON 100%
/ AUTO OFF" AND BE CONTROLLED (CONTINUOUSLY DIMMED) BY THE ASSOCIATED DISTRIBUTED
LIGHTING CONTROLS.
(y)"(y)" INDICATES THAT SWITCH LEG "y" IS TO BE CONFIGURED IN A "MANUAL ON / AUTO OFF"
(VACANCY SENSOR) AND BE CONTROLLED BY THE ASSOCIATED DISTRIBUTED LIGHTING
CONTROLS.
J
J
J
30/1
30/3RF
5
F
y,(y)
(40)
y+,y++
APPLICABLE CODES
2022 CALIFORNIA BUILDING CODE (CBC)
2022 CALIFORNIA ELECTRICAL CODE
2022 CALIFORNIA MECHANICAL CODE (CMC)
2022 CALIFORNIA PLUMBING CODE (CPC)
2022 CALIFORNIA ENERGY CODE
2022 CALIFORNIA FIRE CODE
2022 NATIONAL FIRE ALARM AND SIGNALING CODE
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBSC)
ALLOWED SPECIFICATIONS DEVIATIONS
THE FOLLOWING ITEM(S) ARE ALLOWED DEVIATIONS FROM THE DRAWINGS AND
SPECIFICATIONS. THESE DEVIATIONS ARE AT THE DIRECTION OF THE OWNER.
NONE
SCOPE OF WORK
ELECTRICAL DESIGN FOR RETAIL AND BACKBAR RENOVATION.
DEFERRED APPROVAL
A.FIRE ALARM SYSTEM SHALL BE UNDER SEPARATE PERMIT. SEPARATE PLANS
SHALL BE SUBMITTED FOR APPROVAL BY A FIRE ALARM ENGINEER AND ALL
PERMITS, INSPECTIONS AND APPROVALS SHALL BE OBTAINED FROM THE FIRE
DEPARTMENT HAVING JURISDICTION.
B.VIA SEPARATE SUBMITTAL BY SIGN CONTRACTOR, OBTAIN APPROVALS AND
PERMITS FOR ALL SIGNS INCLUDING SIGN LIGHTING CERTIFICATE OF
COMPLIANCE.
C.VIA SEPARATE SUBMITTAL, OBTAIN APPROVALS AND PERMITS FOR ALL
ELECTRICAL SUBSYSTEMS WITH POWER SUPPLIES OF MORE THAN 50 VA AND/OR
250 VOLTS [E.G. SECURITY, TELCO/DATA, P.A, AUDIOVISUAL, HVAC CONTROLS,
ETC.]
DEMOLITION AND REWIRING SYMBOLS
"E"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN
INDICATES EXISTING TO REMAIN. EXISTING CONDUCTORS TO REMAIN
UNLESS OTHERWISE NOTED ON DRAWINGS.
"EX"IN CONDUIT RUN INDICATES EXISTING CONDUIT RUN TO BE REWIRED.
PULL OUT EXISTING WIRES AND INSTALL NEW WIRES, QUANTITY AS
INDICATED BY HASH MARKS. REFER TO PLANS FOR WIRING
REQUIREMENTS. PROVIDE OTHER SYSTEM CONDUCTORS PER
SPECIFICATIONS.
"EA"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN
INDICATES EXISTING TO BE ABANDONED. REMOVE DEVICE AND INSTALL
BLANK PLATE AND PULL WIRES FROM CONDUIT AS REQUIRED.
"R"ADJACENT TO LIGHT FIXTURE OR OUTLET SYMBOL OR IN CONDUIT RUN
INDICATES EXISTING TO BE REMOVED. EXISTING CONDUIT AND WIRE TO
BE COMPLETELY DISCONNECTED AND REMOVED BACK TO LAST
REMAINING OUTLET OR DEVICE.
"RR"ADJACENT TO ELECTRICAL OUTLET, EQUIPMENT, ETC. INDICATES
EXISTING TO BE REMOVED AND REPLACE WITH NEW.
"RL"ADJACENT TO ELECTRICAL OUTLET, EQUIPMENT, ETC. INDICATES
EXISTING TO BE REMOVED AND RELOCATED.
"EIX"IN CONDUIT RUN INDICATES EXISTING CONDUIT TO BE REWIRED.
INTERCEPT EXISTING WIRES, SPLICE AND EXTEND WIRES TO MATCH
EXISTING. PROVIDE PULLBOX SIZE PER NEC/CEC REQUIREMENT.
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E002
ELECTRICAL
SPECIFICATIONS
PART I - GENERAL
A. CONDITIONS
1.Furnish and install a completely wired and operational electrical system as
shown on the drawings and specified herein, including but not limited to,
these major items.
1.1.Lighting fixtures as indicated and specified on the plans.
1.2.Electrical panels, service, conduit, wiring, etc., for all outlets and
equipment.
1.3.Telephone outlets and conduit as indicated.
B. RELATED WORKS
1.The Electrical Contractor shall provide conduit, trench, and backfill for
electrical service entrance from the main service to utility point of electrical
service. Electrical Contractor shall coordinate the installation of the
electrical service entrance with serving utility company.
2.The Electrical Contractor shall provide conduit, trench, and backfill for
primary phone and CATV service from the telephone terminal board or
cabinet to the phone company and CATV company point of service.
C. CODES, REGULATIONS, AND STANDARDS
1.The installation shall comply with applicable local and state codes and
ordinances, with the regulations of the currently accepted edition of the
National Electric Code and with the requirements of the power, telephone,
and CATV companies furnishing services to this installation.
2.The following industry standards, specifications, and codes are minimum
requirements:
2.1.The National Electrical Code (NEC), including local amendments.
2.2.Underwriter Laboratories (UL) incorporated standards.
2.3.American National Standards Institute (ANSI).
D. INSPECTION OF SITE
1.Prior to submitting a bid for electrical work, the contractor shall visit the site
of the proposed construction and shall thoroughly acquaint himself with
existing utilities, and working conditions to be encountered, etc. Allowance
will not be made for noncompliance with this condition after bidding.
2.Electrical installation shall meet the existing conditions.
E. STORAGE AND HANDLING OF MATERIALS
1.Deliver materials and equipment to the project in the manufacturer's original,
unopened, labeled containers. Protect against moisture, tampering, or
damage from improper handling or storage. Contractor shall protect and be
responsible for any damage to work or materials until final acceptance by
the owner, and shall make good without cost to the owner, any damage or
loss that may occur during this period.
2.Arrange for timely delivery of materials and equipment to the job site in
order to minimize the length of time between delivery and installation.
3.Cover and protect any material which may be affected by the weather while
in transit or stored at the project site. Any material found defective or not
installed in accordance with the contract documents may be rejected by the
engineer.
F. CLEANUP
1.Keep the premises free from accumulation of waste materials, or rubbish
caused by employees or work under this division of the specifications. At
the completion of the work remove all surplus materials, tools, etc., and
leave the premises broom-clean.
G. EXCAVATION
1.Perform all excavation and back filling required for work performed under
this division of the specifications. Use excavated materials for backfill
unless off site materials are deemed necessary.
H. DRAWINGS
1.The drawings indicate the general arrangement and locations of the
electrical work data presented on these drawings are as accurate as
planning can determine, but field verification of all dimensions, locations,
levels, etc., to suit field conditions is required. Review all architectural,
structural, and mechanical drawings and adjust all work to meet the
requirements of conditions shown. The architectural drawings shall take
precedence over all other drawings. Discrepancies between different plans,
or between drawings and specifications, or regulations and codes governing
the installation shall be brought to the attention of the engineer in writing
before the date of bid opening. If discrepancies are not reported, the
Contractor shall bid the greater quantity or better quality, and appropriate
adjustments will be made after contract award. Contractor shall be
responsible to field measure and confirm mounting heights and location of
electrical equipment with respect to counters, radiation, etc. Do not scale
distances off the electrical drawings, use actual building dimensions.
I. EXCAVATION, CUTTING, AND FITTING
1.Perform the excavation, cutting, fitting, repairing, and finishing of the work
necessary for the installation of the equipment of this section. However, no
cutting of the work of other trades or of any structural members shall be
done without the consent of the architect.
J. COOPERATION WITH OTHER CONTRACTORS
1.Cooperate with the other trades so that the installation of the electrical
outlets and equipment will be properly coordinated. Conduit, lighting
fixtures, and other equipment locations shall be checked with other trades to
avoid conflict with the piping, ductwork, steel, beams, or other obstructions.
Carefully check the locations of the outlet boxes and determine that they
have not been disturbed during the installation of materials of other trades.
2.Coordinate the location of the trenches and conduits for electrical and
telephone utility services with the general contractor.
3.Coordinate HVAC equipment connection requirements with HVAC
contractor.
PART II - PRODUCTS AND EXECUTION
A. MATERIALS
1.All materials shall be new and of quality as specified on the plans or
specifications and must carry the Underwriter's Laboratories approval
covering the purpose for which they are used, in addition to meeting all
requirements of the current applicable codes and regulations.
B. CONDUIT
1.All wiring shall be installed in listed metallic conduit except as permitted
below. RGS, with a 20 mil PVC coating will be used when in contact with
earth. IMC may be used in indoor locations not in contact with the earth.
EMT may be used in indoor locations not in contact with earth, not in
concrete slabs or walls and not subject to damage. PVC may be used in or
below concrete and direct buried in earth. Flexible steel conduit shall be
used for indoor final connections to equipment in lengths not to exceed 72".
Liquid-tight flexible steel conduit shall be for outdoor final connections to
equipment not to exceed 36".
2.Cover metallic conduit in contact with earth with polyethylene taped spiral
wrapped, 1/2 lapped to provide 20 mil. thickness. Tape shall be Scotch no.
50 tape. Conduit and ducts not under buildings and feeder ducts shall be
installed per N.E.C. 300-5. make joints with compound to be watertight.
3.Fittings and conduit bodies shall be steel. No diecast fittings.
4.Conduit sizes shall be as required by code and as indicated or specified.
5.All empty conduit systems shall have a nylon pull string to facilitate
installation of future wire.
6.Schedule 40 PVC conduit shall be permitted underground with proper
fittings, all UL Approved and cemented joints. Penetrations through floor
slabs and bends greater than 22° shall be wrapped rigid galvanized steel
elbows.
7.Conduits and outlets shall be concealed with the building structure, except
that certain motor and lighting feeder conduits may be run exposed in
certain areas as indicated on the drawings. Conduit shown to be installed in
cabinets, counters, and casework shall be run as directed by the architect.
8.All conduit systems shall have a Code sized copper ground conductor
increase conduit size as required.
9.Conduit penetration through roof shall have roof flashing with caulk type
counter flashing sleeve. Installation shall be watertight.
10.Conduits shall be routed surface on the structure, parallel and perpendicular
to the structure.
C. OUTLET, PULL, AND JUNCTION BOXES
1.Each switch, light. receptacle or other outlet shall be provided with a Code
gauge, galvanized steel outlet box. Junction and pull boxes shall be Code
gauge, galvanized steel. Outlet boxes shall be of the one piece, knockout
type, in general 4" square with plaster ring. Plaster rings shall be set to
provide not more than 1/8" from wall surface to ring. In no case shall
plaster ring project beyond surface of wall. Single gang rings similar to
Steel City 52050 shall be used for 4" boxes in unfinished brick number 180
boxes may be used for unfinished masonry flush wall outlets. Center all
outlet boxes in block course.
2.Boxes installed in poured cement floors shall be flush type cast iron or steel
with watertight gasketed covers. Where boxes are installed in floors with
tile or carpet floor covering, covers shall be of the recessed type to
accommodate the floor covering.
3.Boxes installed for the alarm, computer, and security system shall be
provided with appropriate cover plates.
4.Boxes for telephone, computer, TV, fire alarm, security, and similar systems
shall be minimum 4" square and 2-1/8" deep.
D. SWITCHBOARDS, DISTRIBUTION BOARDS, MOTOR CONTROL
CENTERS
1.See Single Line Diagram General Notes on drawings for more information.
E. PANEL BOARDS
1.See drawings for panel board schedules and specifications.
F. WIRE
1.Conductor sizes shown on the drawings are based on copper wire. Unless
otherwise specified, all wire shall be Type XHHW for feeders or branch
circuits larger than 4 AWG, Type THHN/THWN insulation for feeders and
branch circuits 4 AWG and smaller. All branch circuit wiring shall be
copper. The wire shall be 12 AWG unless otherwise indicated. Circuit shall
be labeled in each junction box.
2.Metal Clad Cable "Type MC" cable may only be utilized for interior branch
circuitry supplying lighting fixtures, not to exceed 6-ft. in length from junction
box to the fixture served. "Daisy Chaining" of light fixtures is not allowed.
3.When use is permitted in the Allowed Specification Deviations, Metal Clad
"Type MC" cable may be installed per NEC Article 330. Where multiple
cables are routed adjacent to each other (bundled), a minimum separation
of one (1) cable diameter (largest) shall be required.
4.The wires shall be marked with color to simplify circuit identification. Unless
otherwise required by local ordinances:
208/120 Volts
Phase A = Black
Phase B = Red
Phase C = Blue
Neutral = White
Ground = Green
480/277 Volts
Phase A = Brown
Phase B = Orange
Phase C = Yellow
Neutral = Gray
Ground = Green
5.No wire shall be installed in the conduit system until the conduit system is
complete. Use Mineralac No. 100 or equivalent as a lubricant to facilitate
the installation of the conductors in the conduit system.
6.Splices in exterior pull boxes and manholes shall be weatherproof using
"Scotchcast" splice kit or approved equal. Seal ends of conduits and ducts
with "Ductseal" or approved equal.
7.Provide solid conductor for 12 AWG and smaller.
8.Provide 10 AWG conductors for 20 ampere, 120V branch circuits longer
than 75-feet and 8 AWG conductors for 20 ampere, 120V branch circuits
longer than 120-feet. Provide 10 AWG conductors for 20 ampere, 277V
branch circuits longer than 200-feet.
G. WIRING DEVICES
1.Wall switches shall be Specification Grade AC silent type switches, 20A,
120/277 volt.
2.Receptacles shall be Specification Grade, duplex type, NEMA 5-20R, 20
ampere, 120 volt grounded type. Special application receptacles shall be
indicated on plans. Mount with the ground down.
3.Device plates shall be equal to sierra smooth-line plastic wall plates. Color
shall be white, unless otherwise noted.
4.All receptacles identified as weatherproof on the drawings shall be
weather-resistant, tamper-resistant, GFCI type and equipped with enclosure
that is weatherproof (WP) whether or not the attachment plug cap is
inserted (while "IN-USE"). An outlet box hood shall be listed and shall be
identified as "Extra Duty".
5.Except as otherwise noted, all wiring device plates on the project shall be
labeled with panel and circuit number(s) utilizing a Brother P-touch labeling
system with 1/2" tape (yellow on black) or equal HellermannTyton or
Panduit. Locate label on the concealed side of the wiring device plate.
Handwritten labels are unacceptable.
H. LIGHTING FIXTURES
1.Provide all lighting fixtures, wired and connected. the drawings indicate the
fixtures for each location. Provide lamps for all fixtures. The lamps shall be
by the same manufacturer. Verify ceiling construction before ordering
recessed units. Provide plaster frames and hangers as required. Ceiling
construction, architectural accessories, voltage, and ballasts to meet the
existing condition.
I. SERVICE ENTRANCE SECTION
1.The service entrance equipment shall be as indicated on the drawings.
Equipment shall carry the UL label and shall conform to the power company
regulations.
2.Service entrance equipment shall be provided with a fully rated copper or
aluminum bus. Horizontally tapered bussing shall not be allowed.
J. SYSTEM GROUNDING
1.Grounding shall comply with requirements of Article 250. All exposed
non-current carrying metallic parts of electrical equipment, metallic raceway
systems, metallic cable armor, grounding conductor of nonmetallic sheathed
cables, grounding conductor in nonmetallic raceways, and grounded
conductors of the wiring system shall be grounded.
2.Grounding conductor (neutral) of the wiring system shall be connected to
the system grounding conductor at a single place in each system by
removable bonding jumpers, sized according to the applicable provisions of
the National Electrical Code. The grounded conductor (neutral) to the
grounding conductor connection shall be located in the enclosure for the
system's overcurrent protection or where otherwise indicated on the plans
or specifications.
3.A ground bus separate from the neutral bus shall be provided in all
switchboards and panelboards. Ground bus shall be retorqued (checked)
prior to energizing equipment per manufacturer's recommendations.
4.Ground buses and neutral buses in all distribution panels, switchboards,
panelboards, and those provided in any equipment shall be isolated except
where required to be connected as specified above for the service entrance
and in transformer terminal compartments.
5.When indicated on the drawings, equipment grounding conductors shall be
extended from the ground bus in the distribution equipment to the
receptacle, fixture or device lugs where they are provided. Where lugs are
not provided, equipment grounding conductors shall be connected to
equipment enclosures. The connections shall be arranged such that
removal of the receptacle, equipment ground conductors, or ground
jumpers from ground busing shall not affect the ground system.
6.Raceways may not be used as a grounding conductor for power and lighting
circuits. All conduit shall have separate Code sized green ground wire
installed in the conduit to insure a continuos grounding path.
7.In inaccessible locations, make connections by exothermic weld process.
8.In accessible locations, connections shall be made with bolted through,
approved solderless bronze grounding devices.
9.Bond together metal siding not attached to grounded structure bond to
ground.
K. TELEPHONE SYSTEM
1.Telephone wall outlets shall consist of standard boxes mounted 18" above
the floor unless otherwise indicated. Connect outlets to telephone terminal
with separate 3/4" conduit unless otherwise shown on drawings. Provide a
terminal mounting board for the incoming service cable.
L. LIGHTING CONTROL
1.Furnish and install time switches, photocells, contactors and full lighting
control systems as required for lighting controls indicated on the drawings.
2.Time switches shall be equal to Paragon, General Electric, Tork, or
Intermatic and shall have size and number of poles as required.
3.Photocells shall be equal to Tork or Intermatic with voltage as indicated.
M. DRY TYPE TRANSFORMERS
1.Manufacturers: subject to compliance with requirements, provide products
by one of the following
1.1.Acme Electric Corporation; Power Distribution Products Division.
1.2.GE Electrical Distribution & Control.
1.3.Eaton.
1.4.Square D/Groupe Schneider NA.
2. Coils: Continuous windings without splices, except for taps.
3.Internal coil connections - brazed or pressure type.
4.Coil material - copper
5.Enclosure - ventilated, NEMA 250, Type 2 (NEMA 3R for outdoor
installations).
6.Insulation class - 220°C, UL-component-recognized insulation system with
a maximum of 150C° rise above 40°C ambient temperature.
7.Taps for transformers 25 kVA and larger - two 2.5 percent taps above and
four 2.5 percent taps below normal full capacity.
8.Wall brackets - manufacturer's standard brackets.
9.Low-sound-level-requirements - minimum of 3 dba less than NEMA ST-20
standard sound levels when factory tested according to IEEE C57.12.91
N. GUARANTEE
1.Guarantee all material furnished and all workmanship performed for a
period of one year from date of final acceptance of work. Any defects
developing within this period, traceable to material furnished as a part of this
section or workmanship performed hereunder, shall be made good at no
expense to the owner.
O. SHOP DRAWINGS AND APPROVALS
2.The items specified herein and on drawings are used as a standard of
quality. any materials of equal quality and aesthetic value will be given
consideration as a substitute for the materials specified. No approval will be
given to a specific catalog number, model, or type of equipment, prior to
bidding. After bidding, the decision of the Architect and/or Engineer
determining equal materials will be final.
3.The contractor shall submit shop drawings on the following items:
3.1.Lighting fixture cuts and performance data.
3.2.Outline drawings and data sheets of each panelboard and switchboard.
3.3.Outline drawings of all switchgear.
4.Submit items at one time in a neat and orderly manner within 15 days of
award of contract. Partial submittals will not be acceptable.
P. RECORD AND AS-BUILT DRAWINGS
1.The Electrical Contractor shall maintain a set of drawings at the job site for
the exclusive purpose of maintaining a record of all work installed and to
show any deviations from the work indicated on the drawings.
2.At the completion of the project, one set of reproducible drawings, showing
all As-Built conditions, shall be delivered to the Owner for acceptance prior
to final payment.
Q. HOUSEKEEPING PADS
1.Provide a minimum of 3" high housekeeping pad above finished floor/
finished grade for all floor-mounted switchgear, switchboards, distribution
boards, transformers, motor control centers, etc., flush with the face of the
equipment. Located in mechanical central plants(s), other mechanical
spaces, and located outdoors, pads shall be flush with the face of the
equipment. Confirm pad dimensions with local inspector prior to forming
pad to ensure any local code interpretations/conditions are met regarding
housekeeping pads.
2.Unless otherwise noted above, provide a minimum of 1-1/2" high
housekeeping pad above finished floor/finished grade for all interior
floor-mounted switchgear, distribution boards, transformers, motor control
centers, transfer switches, etc., flush with the face of the equipment. All
housekeeping pad heights are as measured from finished floor or grade.
Confirm pad dimensions with local inspector prior to forming pad to ensure
local code interpretations/conditions are met regarding housekeeping pads.
3.Provide a 1-1/2" high housekeeping pad above finished floor/finished grade
for service equipment. Prior to pad rough-in, Contractor shall verify serving
utility company's maximum meter height requirements and, if necessary,
adjust height of housekeeping pad to comply with those requirements. In
indoor applications, the housekeeping pad shall be flush with the face of the
switchgear. In outdoor applications, the housekeeping pad shall extend a
minimum of 4 feet from the front of switchgear's weatherproof enclosure.
Confirm pad dimensions with local inspector prior to forming pad to ensure
any local code interpretations/conditions are met regarding housekeeping
pads.
4.All housekeeping pads located in, on, or attached to a building shall be
seismically braced/connected to the building structure.
R. EQUIPMENT CONNECTIONS
1.Provide flexible connections to all HVAC equipment, water heater, etc any
equipment over 20 lb and/or mounted above finished floor.
2.Coordinate electrical requirements for all plumbing and mechanical
equipment with final Contractor selection. The Contractor shall size
disconnects based upon circuit breaker ratings and provide fusing as
required per equipment manufacturer recommendations and UL Listing
requirements.
S. MOTORS
3.Where motors are installed in suspended ceilings, contractor shall provide
disconnect switch in suspended ceiling within reach from access point.
4.Sizing of motor-related electrical components, including feeder and/ or
branch circuits (wire and conduit) and overcurrent protection (breaker and/
or fuses) is based on ratings indicated in the contract documents as well as
NEC approximated loads for a given motor horsepower, voltage and phase.
It is the contractor's responsibility to verify actual motor and appliance rating
and loads. Contractor to provide correctly sized motor overload electrical
components based on nameplate rating. Reflect all changes in the as-built
drawings.
T. FIRE SYSTEM
1.Contractor shall engage the services for a state licensed fire alarm
manufacturer/installer to prepare all design drawings and calculations
required for system approval by the authority having jurisdiction. Submit all
plans and provide all permits required for a complete and operable
approved life safety system.
2.Fire alarm device wiring shall be minimum #14 AWG copper or per system
manufacturer requirements. Provide minimum 3/4" separate raceway
system or as required for life safety system wiring configuration.
3.Upon completion of the installation of life safety system wiring and devices,
a performance test of the entire life safety shall be performed to the
satisfaction of the authority having jurisdiction.
U. LOW VOLTAGE SYSTEMS
1.Music, television, video mounting systems are not shown on these drawings
and are provided by Contractor through architects schedules/details.
Contractor to coordinate all routing and final connections as approved by
Starbucks Manager as applicable specifically to this store.
V. IDENTIFICATION OR EQUIPMENT LABELING
1.Nameplates shall be provided for switchgear, switchboards, distribution
boards, distributions panels, panel boards, motor control centers,
transformers, transfer switches, contactors, starters, disconnect switches,
enclosed circuit breakers/switches, Inverters, UPS's, PDU's, RDC's, SPD's,
lighting control panels, dimming panels, door releasing system panels, fire
alarm/central monitoring terminal cabinets/power supplies/control panels,
and all low voltage system terminal and control cabinets.
1.1.Nameplate inscriptions shall be identical to the equipment designations
indicated in plans and specifications. Nameplates shall be engraved
with the device designation/identification on the top line, source
identification for the device on the 2nd line per NEC, Art 408.4 and load
designation for the device on the bottom line. Where load designation
consists of a branch circuit, omit bottom line. Where device
designation is not intended on plan/specfications. Contractor shall
submit a written clarification request to the Engineer.
1.2.All circuit breakers/fuses in switchgear, switchboards, distribution
boards, distribution panels, UPS output circuit breakers, PDU sub-feed
circuit breakers and motor control centers shall have individual
nameplates located immediately adjacent to the respective device.
Nameplate inscription shall identify the downstream equipment or
device served by the circuit breaker or fuse.
2.Identification nameplates, unless otherwise noted (UON), shall be
laminated/extruded modified acrylic or melamine plastic labels that is 3/32"
thick, UV-stabilized, matte finish, suitable for use in 180°F ambient, with
beveled edges and engraved white letters 3/8" high, minimum, on 1-1/2"
high black background for single line of text. Where two lines of text are
required, provide minimum 2" high nameplate. Where three lines of text are
required, provide 2.5" high nameplate. Provide white letters on red
background for all NEC, Article 517 essential power systems, Article 700
Emergency Systems, Article 701 Legally Required Standby Systems and
Article 708 COPS.
3.Identification nameplates for new switchgear, switchboards, distribution
boards, distribution panels, panel boards and motor control centers shall be
attached with switchgear manufacturer-provided screws via switchgear
manufacturer factory pre-drilled holes. A factory option to rivet identification
nameplates to the equipment is only acceptable if screw-fastened
nameplates are not an available option from the switchgear manufacturer.
Field drilling or other mechanical attachment methods that change/void the
NEMA or NTRL rating of the enclosure are strictly forbidden.
4.Identification nameplates for transformers, transfer switches, disconnect
switches, enclosed circuit breakers/switches, inverters, UPSs, PDUs, RDCs,
SPDs, lighting control panels, dimming panels, door-releasing system
panels, terminal cabinets and all circuit breakers/fuses in switchgear,
switchboards, distribution boards, distribution panels, UPS output circuit
breakers, PDUs, PDU sub-feed circuit breakers, and motor control centers
shall be attached to the equipment by self-adhesive backing integral to the
nameplates. When equipment is located outdoors, provide nameplates
without self-adhesive backing and attach to equipment using weather-rated,
UV-resistant epoxy. In all cases, clean surfaces before applying
identification nameplates parallel to equipment lines.
5.Warning Placards, as required by General Single Line Diagram Notes for
multiple power sources, or instruction placards, as required for all kirk-key
interlock schemes, all UPS bypass procedures or as required elsewhere in
the plans/specifications shall be engraved 1/2" high with white lettering on
red background using the same material specified for identification
nameplates with a self-adhesive backing. Warning/instruction placards shall
be attached to the face of the equipment directly related to the placards.
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
L 20794
(6)
L 21783
L 20748 L 21774 (2)
(7)
L 21772 (2)L 21772 (4)
L 21774 (2)
L 20748
L 21776 (12)
L 21776 (8)
L 21772 (3)
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
(N) GYP BD CEILING
AT 9' - 0" AFF
(N) 2X4 ACT AT
10' - 0" AFF
(N) 2X4 ACT CIRRUS
SECOND LOOK III
AT 13' - 0" AFF
(N) GYP BD CEILING
AT 9' - 0" AFF
(N) GYP BD CEILING
AT 9' - 0" AFF
(N) GYP BD CEILING
AT 13' - 0" AFF
(N) GYP BD CEILING
AT 13' - 0" AFF
(N) SOFFIT AT
11' - 0" AFF
(N) SOFFIT AT
11' - 0" AFF
7' - 6"
(N) SIREN SOFFIT
(PAINT FINISH)
(3)
L 21772 (8)
(4)L 22217
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
L 22251
7' - 6"
7' - 6"
GYP. HEADER
(PAINT FINISH)
GYP. HEADER
(FRP FINISH)
7' - 6"
(N) HEADER
L 21776
(2)
L 21772 (10)
12' - 5"
RAISED ACT
CEILING
(4)
1k1k
1k
1k
1k
1k
1k
1k
1w/1EB
1w
1w
1w
1NL/1EB
1w
1w/1EB
9m/9EB 9p
7n
7u
3b
7u
7u
9m
9p
9p 9p/9EB
7n
7n
3b 3b 3b
3b 3b
3b/3EB
3b 3b
3b/3EB
3b 3b 3b
3b
3b
3b
3b
3b
3b
3b
3b
3b/3EB
3b
3b
3b
3b
3b
3b/3EB
5y 5y 5y
5r/5EB 5r5r
5r 5r/5EB 5r
5r
5r/5EB
3c
3c
1NL/1EB
5NL/5EB
1
2
A3
A2
HP A3-1 3
A3-3 3
A3-5 3
A3-7
5
4
6
7
3g
3g
A3-9
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E200
LIGHTING PLAN
SCALE:1/4" = 1'-0"1 LIGHTING PLAN
REFERENCE NOTES
NEW LUTRON SWITCHBANK, REFER TO LUTRON ONE-LINE AND LOOP LAYOUT.
LIGHT SWITCHES ARE SPECIFIED ON LUTRON ONE-LINE.
NEW EMERGENCY/EXIT FIXTURE, GC TO PERFORM TEST TO ENSURE
EMERGENCY BATTERY UNIT WILL PROVIDE BACKUP POWER FOR MINIMUM 90
MINUTES.
ROUTE CIRCUIT VIA LUTRON VIVE SYSTEM TIME CLOCK.
RELOCATED EXISTING EMERGENCY EXIT LIGHT/SIGN.
EXISTING EMERGENCY EXIT LIGHT/SIGN TO REMAIN. MOUNT WITHIN NEW
CEILING AT SAME LOCATION PER NEW WORK.
DASHED LINE INDICATES LED STRIP BELOW. HOUSED WITHIN SOFFIT
OVERHANG.
DASHED LINE INDICATES LED STRIP BELOW. HOUSED WITHIN COUNTERTOP
OVERHANG.
1
2
3
4
5
6
7
A.PROVIDE A DISCONNECTING MEANS FOR EACH MULTI-WIRE LIGHTING
BRANCH CIRCUIT IN ACCORDANCE WITH NEC 410.130(G)(1)THRU(3).
DISCONNECTING MEANS SHALL BE LOCATED AT POINT WHERE CIRCUIT
ORIGINATES AND SHALL SIMULTANEOUSLY DISCONNECT ALL
UNGROUNDED CONDUCTORS.
B.REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT
LOCATION AND ELEVATION OF ALL LIGHTING FIXTURES.
C.THE FIXTURE SCHEDULE INDICATES GENERAL DESCRIPTION OF LIGHTING
FIXTURES AND MANUFACTURERS CATALOG NUMBERS. IT SHALL BE THE
CONTRACTORS RESPOSIBILITY TO VERIFY EXACT CEILING CONSTRUCTION
WITH ARCHITECTURAL REFLECTED CEILING PLAN AND PROVIDE LIGHTING
FIXTURES WITH ALL NECESSARY TRIMS, AND MOUNTING HARDWARE.
D.COORDINATE EXACT LIGHTING FIXTURE LOCATIONS WITH ELECTRICAL,
MECHANICAL, PLUMBING EQUIPMENT, INCLUDING CONDUIT, PIPING,
DUCTING ,ETC PRIOR TO ROUGH-IN.
E.ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIRED
STRUCTURAL SUPPORTS AS REQUIRED BY THE CURRENTLY ADOPTED
ISSUE OF THE BUILDING CODE, AS WELL AS ANY LOCAL CODES.
F.ALL DIMMING BRANCH CIRCUITS SHALL BE PROVIDED WITH A DEDICATED
NEUTRAL CONDUCTOR FOR EACH ZONE/CHANNEL.
G.ALL EMERGENCY BATTERY PACK FIXTURES SHALL BE PROVIDED WITH A
CONSTANT HOT CONNECTION TO THE CHARGING LEAD OF THE LOCAL
AREA CIRCUIT.
H.REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGN
CHEVRONS AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIES
BETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL AND ARCHITECTURAL
PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR
TO ORDERING EXIT SIGNS. A JUNCTION BOX MUST BE PROVIDED WITH ALL
EXIT LIGHTS CONNECTED TO MORE THAN ONE SET OF CONDUCTORS
UNLESS THE EXIT LIGHT FIXTURE IS FURNISHED WITH AN APPROVED
OUTLET BOX FOR THROUGH WIRING.
I.ALL LOW VOLTAGE LIGHTING SYSTEMS SHALL COMPLY WITH NEC 411 AND
SHALL BE LISTED PER 411.3 OR LOCAL CODES HAVING JURISDICTION.
J.ALL ELECTRICAL EQUIPMENT LOCATED OUTSIDE SHALL BE
WEATHERPROOF.
K.ALL LOW VOLTAGE WIRING NOT RUN IN CONDUIT SHALL BE PLENUM RATED.
L.MOUNT ALL SWITCHES, CONTROLS, RECEPTACLES BETWEEN 15"-48" AFF.
H.ADDITIONAL RELAY ZONES MAY BE REQUIRED FOR THE ADDITION OF
PRIMARY DAYLIT, SECONDARY DAYLIT, AND PRIMARY SKYLIT UTILIZING THE
SAME CONTROL CHANNEL. (I.E. EVEN THOUGH A SINGLE LETTER "a" IS
INDICATED AT THE PRIMARY SENSOR), ADDITIONAL RELAYS WOULD BE
REQUIRED FOR THE:
"a+"PRIMARY SIDELIT DAYLIT ZONE
"a++"SECONDARY SIDELIT DAYLIT ZONE, AND
"a*"SKYLIT DAYLIT ZONE
WHERE MORE THAN ONE CIRCUIT /THREE SWITCH LEGS/THREE RELAY
ZONES ARE REQUIRED PROVIDE ADDITIONAL FULL FEATURE CONTROL
UNITS AS REQUIRED.
I.LUMINAIRES INDICATED AS EMERGENCY SHALL BE IDENTIFIED / PROVIDED
AS FOLLOWS:
-FIXTURE CONNECTED TO CIRCUIT "3", CONTROL SWITCH
"a" - WITH THE BATTERY CHARGING LEAD CONNECTED
TO A CONSTANT HOT CIRCUIT "3".
-FIXTURE CONNECTED TO A CONSTANT HOT CIRCUIT "#3".
BATTERY CHARGING LEAD CONNECTED TO A CONSTANT
HOT CIRCUIT "3".
-ROUTED THROUGH A U.L. LISTED TRANSFER RELAY (LC &
D # GR - 2001E/S) FOR SWITCHED CONTROL OR A U.L.
LISTED TRANSFER SWITCH (BODINE #GTD SERIES
DEVICE) FOR DIMMING CONTROLS . CONNECTED TO A
CONSTANT HOT EMERGENCY CIRCUIT "3".
-FIXTURE CONNECTED TO A CONSTANT HOT EMERGENCY
CIRCUIT "#3".
1.INTEGRAL BATTERY PACK (EB):
3a/3EB
3NL/3EB
3a/3EM
3NL/3EM
2.REMOTE BACK-UP SOURCE (EM)
LIGHTING PLAN GENERAL NOTES
4 1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E210
LUTRON
ONE-LINE DIAGRAM
FOR REFERENCE
ONLY
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E220
LUTRON
LOOP LAYOUT
FOR REFERENCE
ONLY
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
.
.
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
2' - 10 1/2"
10267
A3-39
23454
A3-41
A3-37
A3-37
+72"
23
4
2
3
A3
-
3
5
23
1
8
1
A2
-
2
3
,
2
5
1
E310
1
E320
A3
A2
HP
W
A2
-
3
5
V
A2
-
3
7
V
A2
-
3
9
X
A2
-
4
1
13
6
7
6
A2
-
4
2
Y
A2
-
4
0
R A3-38,40,421
100AS
3P
T HP-40,42
HP-7
2
3
TYP
4
5
HP-16
HP-18
2
E320
23181 A3-29
FOR AIR
CURTAIN
A
A
(E)
(E)
(E)
EXISTING ITEMS TO
PRESERVE AND RELOCATE
A PASTRY CART
B BLENDERS (3)
C 1-DR U/C FRIDGE (6)
D WARMING U/C FRIDGE
E ESPRESSO MACHINES (2)
H CUP LABELER (3)
G GRINDER
F CUP CADDY (2)
I NITRO TAP
J NITRO GENERATOR
X 1-DR REACH IN FREEZER
Y 2-DR REACH IN FREEZER
Z DATA RACK
K NITRO KEG DISPENSER
L WARMING OVENS
M U/C THAW RACK
R R.O. SYSTEM & WATER HEATER
T SANITIZER
Q MANAGER'S EQUIPMENT
S METRO RACKS (10)
N DRIVE-THRU POS EQUIPMENT
O POS EQUIPMENT, PRINTER, & PHONE
P SAFE
U THAW RACK (2)
V 1-DR REACH IN FRIDGE (2)
W 2-DR REACH IN FRIDGE
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
Revision Schedule
Rev Date By Description
A 12/24/2023 PLAN CHECK
E300
POWER PLAN
SCALE:1/4" = 1'-0"1 POWER PLAN
A.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND
OFFSET 24" MINIMUM.
B.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED
FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL
OR GREATER THAN THE FIRE RATING OF THE WALL.
C.HEIGHT OF ALL RECEPTACLES AT COUNTER SHELVES, ETC., SHALL BE
VERIFIED WITH OWNER PRIOR TO ROUGH-IN. PROVIDE G.F.C.I. TYPE
RECEPTACLE WITHIN 6 FEET OF ANY SINK.
D.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C.
RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR.
E.EACH AND EVERY 125VAC THROUGH 250VAC RECEPTACLE SUPPLIED BY A
SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND,
50 AMPERES OR LESS, AND ALL THREE-PHASE RECEPTACLES RATED 150
VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS INSTALLED IN
KITCHEN, FOOD PREPARATION, BAR AREAS AND RESTROOMS SHALL HAVE
A GROUND FAULT CIRCUIT-INTERRUPTER PROTECTED RECEPTACLE OR
RECEPTACLE(S) PROTECTED BY GFCI CIRCUIT BREAKER. ANY RECEPTACLE
INSTALLED WITHIN 6 FEET OF A SINK MUST BE G.F.C.I. TYPE.
F.FOR ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30
AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES TO BE
LOCATED:
A. NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, AND
B. NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF
THE FINISHED FLOOR OR WORKING PLATFORM.
G. CIRCUIT NUMBERS ARE BASED ON CURRENT PANEL SCHEDULES. WHERE
CIRCUIT IS TO BE REPLACED OR RELOCATED, CONTRACTOR IS TO VERIFY
CORRECT NUMBERING AND UPDATE THE PANEL SCHEDULE.
H. ELECTRIC OUTLETS, SWITCHES, THERMOSTATS, FIRE ALARMS AND SIMILAR
DEVICES SHALL BE LOCATED A MINIMUM OF 15" ABOVE THE FINISHED
FLOOR, MEASURED TO THE BOTTOM OF THE BOX, AND A MAXIMUM OF 48"
ABOVE THE FINISHED FLOOR, MEASURED TO THE TOP OF THE BOX.
J. ALL PANEL CIRCUIT NUMBERS ARE FOR REFERENCE ONLY, AND ARE BASED
ON EXISTING PANEL SCHEDULES FOUND AT SITE. CONTRACTOR TO
PROVIDE AN UPDATED PANEL SCHEDULE TO OWNER UPON COMPLETION.
K.ELECTRIC WATER HEATERS MUST BE PROVIDED WITH A DISCONNECT. THE
CIRCUIT BREAKER MAY SERVE AS THIS DISCONNECT WHEN IT IS WITHIN
SIGHT OF THE WATER HEATER OR WHEN PROVIDED WITH A LOCK-ON /
LOCK OFF FEATURE.
POWER PLAN GENERAL NOTES
REFERENCE NOTES
PROVIDE 3#4 & 1#8 EGC IN 1-1/4" C
PROVIDE 2#6 & 1#10 EGC IN 3/4" C
TAMPER-RESISTANT RECEPTACLE OUTLET WITH USB CHARGING PORT
PROVIDED BY BANQUETTE SEATING SUPPLIER. COLOR TO MATCH
BANQUETTE SEATING. ELECTRICAL CONTRACTOR TO PROVIDE CONNECTION
TO JUNCTION BOX.
JUNCTION BOX FOR BANQUETTE SEATING SUPPLIED RECEPTACLE OUTLETS.
INDICATES AUTOMATIC DOOR OPENER PUSH PAD.
1
2
3
4
5
STAMP DATE: 12/24/2023
Email: info@peccusa.com
Phone: 909.610.5364
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
22
6
4
2
HP
-
2
3
C
22
6
4
2
HP
-
2
5
C
DHP-27
LHP-15,17
LHP-32,34
E
HP
-
2
8
,
3
0
E
HP
-
3
6
,
3
8
2
2
HA3-26
12618HP-27
22
H
A3
-
2
6
22
6
4
2
HP
-
3
3
C
19
7
4
2
HP
-
2
9
,
3
1
2
2
PA2-16
2
A2-18
23444HP-35,37
22885 HP-11,13
G HP-7
2
E330
1
E330
16
2
3
9
A2
-
2
7
,
2
9
A3-32
10267A2-9
23442HP-22,24,26
4
22970 A2-11
3
4
3
3
5
A2-28
2 2
2
2A2-4
6
OA2-14
CA2-7
A
A
A
EXISTING ITEMS TO
PRESERVE AND RELOCATE
A PASTRY CART
B BLENDERS (3)
C 1-DR U/C FRIDGE (6)
D WARMING U/C FRIDGE
E ESPRESSO MACHINES (2)
H CUP LABELER (3)
G GRINDER
F CUP CADDY (2)
I NITRO TAP
J NITRO GENERATOR
X 1-DR REACH IN FREEZER
Y 2-DR REACH IN FREEZER
Z DATA RACK
K NITRO KEG DISPENSER
L WARMING OVENS
M U/C THAW RACK
R R.O. SYSTEM & WATER HEATER
T SANITIZER
Q MANAGER'S EQUIPMENT
S METRO RACKS (10)
N DRIVE-THRU POS EQUIPMENT
O POS EQUIPMENT, PRINTER, & PHONE
P SAFE
U THAW RACK (2)
V 1-DR REACH IN FRIDGE (2)
W 2-DR REACH IN FRIDGE
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
Revision Schedule
Rev Date By Description
A 12/24/2023 PLAN CHECK
E310
ENLARGED
ENGINE PLAN
SCALE:1/2" = 1'-0"1 ENLARGED FF&E POWER PLAN
A.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND
OFFSET 24" MINIMUM.
B.ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED
FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL
OR GREATER THAN THE FIRE RATING OF THE WALL.
C.HEIGHT OF ALL RECEPTACLES AT COUNTER SHELVES, ETC., SHALL BE
VERIFIED WITH OWNER PRIOR TO ROUGH-IN. PROVIDE G.F.C.I. TYPE
RECEPTACLE WITHIN 6 FEET OF ANY SINK.
D.ALL UNDERGROUND CONDUITS SHALL BE PVC SCHED. 40, MINIMUM 3/4"C.
RUN CODE SIZE INSULATED EQUIPMENT GROUND CONDUCTOR.
E.EACH AND EVERY 125VAC THROUGH 250VAC RECEPTACLE SUPPLIED BY A
SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND,
50 AMPERES OR LESS, AND ALL THREE-PHASE RECEPTACLES RATED 150
VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS INSTALLED IN
KITCHEN, FOOD PREPARATION, BAR AREAS AND RESTROOMS SHALL HAVE
A GROUND FAULT CIRCUIT-INTERRUPTER PROTECTED RECEPTACLE OR
RECEPTACLE(S) PROTECTED BY GFCI CIRCUIT BREAKER. ANY RECEPTACLE
INSTALLED WITHIN 6 FEET OF A SINK MUST BE G.F.C.I. TYPE.
F.FOR ELECTRICAL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30
AMPERES OR LESS AND COMMUNICATION SYSTEM RECEPTACLES TO BE
LOCATED:
A. NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, AND
B. NO LESS THAN 15 INCHES MEASURED FROM THE BOTTOM OF THE
RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING, TO THE LEVEL OF
THE FINISHED FLOOR OR WORKING PLATFORM.
G. CIRCUIT NUMBERS ARE BASED ON CURRENT PANEL SCHEDULES. WHERE
CIRCUIT IS TO BE REPLACED OR RELOCATED, CONTRACTOR IS TO VERIFY
CORRECT NUMBERING AND UPDATE THE PANEL SCHEDULE.
H. ELECTRIC OUTLETS, SWITCHES, THERMOSTATS, FIRE ALARMS AND SIMILAR
DEVICES SHALL BE LOCATED A MINIMUM OF 15" ABOVE THE FINISHED
FLOOR, MEASURED TO THE BOTTOM OF THE BOX, AND A MAXIMUM OF 48"
ABOVE THE FINISHED FLOOR, MEASURED TO THE TOP OF THE BOX.
J. ALL PANEL CIRCUIT NUMBERS ARE FOR REFERENCE ONLY, AND ARE BASED
ON EXISTING PANEL SCHEDULES FOUND AT SITE. CONTRACTOR TO
PROVIDE AN UPDATED PANEL SCHEDULE TO OWNER UPON COMPLETION.
K.ELECTRIC WATER HEATERS MUST BE PROVIDED WITH A DISCONNECT. THE
CIRCUIT BREAKER MAY SERVE AS THIS DISCONNECT WHEN IT IS WITHIN
SIGHT OF THE WATER HEATER OR WHEN PROVIDED WITH A LOCK-ON /
LOCK OFF FEATURE.
REFERENCE NOTES
DENOTES POWER AND DATA OUTLETS FOR DIGITAL MENU BOARDS. REFER
TO DWG. I504 FOR ACTUAL LOCATIONS.
PROVIDE 2#8 & 1#10 EGC IN 3/4"C
PROVIDE 2#10 & 1#10 EGC IN 1/2"C
PROVIDE 3#6 & 1#10 EGC IN 1"C
PROVIDE 3#10 & 1#10 EGC IN 3/4"C
INDICATES POWER AND DATA OUTLETS FOR ORDER STATUS STATUS BOARD.
REFER TO DETAL 3/I504 FOR ADDITIONAL INFORMATION.
1
2
3
4
5
6
POWER PLAN GENERAL NOTES
STAMP DATE: 12/24/2023
Email: info@peccusa.com
Phone: 909.610.5364
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
PLAN VIEW
PRINTER
380MM
1' - 3"
4'
-
0
"
(
1
2
2
0
M
M
)
A
.
F
.
F
.
110MM
4 1/4"
25MM
1"
670MM
2' - 2 1/4"
1
SECURE KEY BOX
MUSIC SYSTEM PLAYER AND
AMPLIFIER (FURNISHED BY OWNER,
INSTALLED WITH SPEAKER SYSTEM
BY GC) ON 14" DEEP (355MM) SHELF
ONLY (MIN.) (NOT IN EQUIP. RACK).
CEILING HEIGHT SHOWN AT 96"
(2440MM). REFER TO
REFLECTED CEILING PLAN(S)
FOR ACTUAL HEIGHT.
WALL MOUNTED SHELVING
UNIT ATTACHED TO BACKER
BOARD
HOME PHONE
CONNECT (HPC)
CASH SCALE
ROLLING CART
IPOD TOUCH
CHARGING CRADLE
NOTE :EQUIPMENT SHOWN AS DASHED LINES IS TO BE FURNISHED
AND INSTALLED BY OWNER UNLESS NOTED OTHERWISE.
ROLLING CART
SHELVING ABOVE
DESK
SLEEVE FOR LOW VOLTAGE CABLE
BUNDLE MOUNTED TO (2) UNISTRUTS
POWER & DATA RECEPTACLES
(IN WALL, AT MUSIC SYSTEM SHELF)
(1) DUPLEX RECEPTACLE FOR:
MUSIC SYSTEM AMPLIFIER AND
FUTURE USE
(1) 2-DATA PORT FOR:
CURIO
POWER, TELEPHONE & DATA RECEPTACLES
(IN WALL, BELOW DESK)
(1) QUAD RECEPTACLE FOR:
PC, PRINTER, PHONE AND HPC
(1) QUAD RECEPTACLE FOR:
LAPTOP, CASH SCALE AND FUTURE USE
(1) QUAD RECEPTACLE
(1) PHONE MAIN
(1) 2-DATA PORT FOR:
PC AND PRINTER
A
LOW VOLTAGE
CABLE BUNDLE
1 MUSIC SYSTEM
PLAY NETWORK
SPEAKERS
2" (50MM) Ø SLEEVE FOR LOW
VOLTAGE CABLE BUNDLE
MOUNTED TO (2) UNISTRUTS
CEILING TRIM RING
60" W X 70" H (1525MM W X
1780MM H) MIN. 3/4" FIRE RATED
PLYWOOD BACKER BOARD.
FASTEN TO STRUCTURE TO
HOLD MIN. 350 PSF. PAINTABLE
SURFACE ON ROOM SIDE &
FINISH AS SCHEDULED.
POWER, TELEPHONE & DATA
RECEPTACLES AT 12" (305MM) A.F.F.
TO CENTER OF GROUPING. SEE
FLAN VIEW NOTE "A" ABOVE FOR
DESCRIPTION.
A
POWER & DATA RECEPTACLES
AT 60" (1525MM) A.F.F. TO
CENTER OF GROUPING. SEE
NOTE 'B ' ABOVE FOR
DESCRIPTION.
DESK
OFFICE PC
LAPTOP
CORDLESS 1 LINE PHONE
ELEVATION VIEW
B
LOW VOLTAGE CABLE BUNDLES
SECURITY PANEL
FUTURE USE
- - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - -
2 SECURITY1 POS
HIGH SPEED INTERNET
DEMARC EXTENSION
POS LAN
DT TIMER
POWER & DATA RECEPTACLES
(IN WALL, ABOVE SHELVES)
(1) QUAD RECEPTACLE FOR:
EMS DATA CONCENTRATOR
(1) DUPLEX RECEPTACLE FOR:
SECURITY CONTROL ALARM PANEL
(1) 2-DATA PORT FOR:
EMS DATA CONCENTRATOR
B
(2) 2" (50 MM) Ø
SLEEVES FOR
LOW VOLTAGE
CABLE BUNDLES
MOUNTED TO
(2) UNISTRUTS
CEILING TRIM
RING (TYP.)
ENLARGED VIEW
SECURITY
CONTROL
ALARM PANEL
EMS DATA
CONCENTRATOR.
ALLOW 2" (50MM)
IN. CLEAR ABOVE
56" W X 42" H (1420MM W X 1065MM H) MIN. 3/4" FIRE RATED
PLYWOOD BACKER BOARD. FASTEN TO STRUCTURE TO
HOLD MIN. 350 PSF. PAINTABLE SURFACE ON ROOM SIDE
AND FINISH AS SCHEDULED.
MINI GROUND BAR FOR EQUIPMENT RACK. GC TO
COORDINATE RACK GROUNDING TO BAR WITH #6 GROUND
WIRE AND PER JURISDICTIONAL REQUIREMENTS
POWER & DATA RECEPTACLES AT 87" (2210MM)
A.F.F. TO CENTER OF GROUPING. SEE PLAN VIEW
NOTE "A" ABOVE FOR DESCRIPTION.
610MM
2' - 0" CLEAR
EQUIPMENT RACK WALL MOUNTED TO STRUCTURE BY
STARBUCKS VENDOR (GC TO COORDINATE INSTALLATION).
GROUND RACK PER MFR'S ASSEMBLY INSTRUCTIONS. SEE
EQUIPMENT RACK SCHEDULE BELOW FOR EQUIPMENT
INCLUDED WITHIN.
PLAN VIEW
LAY-IN
CEILING
MOUNT GROUND BAR AT 116" (2945MM) A.F.F.
WIRELESS MODEM AT 92"
(2335MM) A.F.F. STARBUCKS
VENDOR TO DETERMINE
OPTIMAL DEVICE LOCATION
DEMARC, IF REQUIRED
POWER AND DATA
RECEPTACLES AT 104"
(2642MM) A.F.F. TO
CENTER OF GROUPING.
SEE NOTE 'B ' ABOVE FOR
DESCRIPTION
UPS
IPS EQUIPMENT
ROUTER
EQUIPMENT RACK SCHEDULE
NETWORK SWITCH
PATCH PANEL
SECURITY RECORDER (NVR)
SECURITY KEYBOARD
PRODUCTION CONTROLLER DEVICES
SECURITY MONITOR
MOUNTED ON MONITOR
ARM (ATTACHED TO
BACKER BOARD).
NOTE :EQUIPMENT SHOWN AS DASHED
LINES IS TO BE FURNISHED AND
INSTALLED BY OWNER UNLESS
NOTED OTHERWISE.
ELEVATION VIEW
MOUNT EQUIPMENT RACK AT 84" (2133MM) A.F.F.
7'
-
0
"
EQ EQ
76" (1930MM)
CLEAR AREA
BELOW FOR
TRASH
CONTAINERS,
STORAGE OR
DELIVERY
DROP OFF
BACK OF HOUSE CEILING
HEIGHT PER PLAN
LAY-IN RAISED CEILING HEIGHT AT 120"
(3050MM) A.F.F. ABOVE TECH. EQUIPMENT
1 2
6"
6"
15
0
M
M
.
15
0
M
M
.
..4"
100MM
1980MM
6' - 6" CLEAR
12
9
5
M
M
4'
-
3
"
.
940MM
3' - 1"
65MM
2' - 2 1/2"
370MM
1' - 2 1/2"
50
M
M
2"
MAINTAIN 24" (610MM) MIN.
CLEARANCE FOR WHEN
EQUIPMENT RACK IS IN
OPEN ACCESS POSITION
(2) SLEEVES FOR
LOW VOLTAGE CABLE
BUNDLES MOUNTED
TO (2) UNISTRUTS
EQUIPMENT RACK
2
A POWER RECEPTACLES
(IN WALL, BEHIND OF EQUIPMENT RACK)
(1) INDIVIDUAL BRANCH CIRCUIT RECEPTACLE FOR:
UPS
(1) DUPLEX RECEPTACLE FOR:
PDU STRIP AND FUTURE USE
BULKHEAD WALL FOR
RECESSED CEILING
ABOVE EQUIPMENT
RACK
IOT GATEWAY
2
2 HP-21
HP
-
1
9
HP
-
1
9
HP
-
1
9
A3-8 A3-6
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E320
ELECTRICAL
DETAILS
SCALE:3/4" = 1'-0"1 MANAGER'S DESK
SCALE:3/4" = 1'-0"2 EQUIPMENT RACK
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER EXPEDITOR,
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA J-BOX
4-DATA J-BOX
POWER AND DATA RECEPTACLES
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT.
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA J-BOX
SINGLE DATA J-BOX
POWER AND DATA RECEPTACLES
QUAD RECEPTACLE
FOR UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
POWER RECEPTACLE
UNDERCOUNTER
REFRIGERATOR
DUPLEX CONVENIENCE
POWER RECEPTACLE
EDGE OF COUNTERTOP
NOTE:EQUIPMENT SHOWN AS
DASHED LINES IS TO BE
FURNISHED AND INSTALLED BY
OWNER UNLESS NOTED
OTHERWISE
DRIVE THRU DIGITAL
PRODUCTION MONITOR
ELEVATION VIEW
DRIVE THRU TENDERING REGISTER
TRIPLE MONITOR MOUNT (GC INSTALLED)
SEE PLAN VIEW FOR MOUNTING LOCATION
POWER RECEPTACLES AT 28" (711MM) TO
TOP OF RECEPTACLE A.F.F.
DEDICATED QUAD RECEPTACLE FOR DT
DIGITAL PRODUCTION MONITOR, UPS UNIT
(FOR TENDERING REGISTER, EXPEDITOR
POS AND PED) AND FUTURE USE
DEDICATED QUAD RECEPTACLE FOR
FUTURE USE
2-DATA PORT FOR TENDERING REGISTER
AND EXPEDITOR POS
4-DATA PORT FOR DT VIDEO, PED AND/OR
CONNECT DEVICES
POS BANK (TYP)
CASH DRAWERS
ELEVATION VIEW
DRIVE THRU VIDEO CONDUIT FROM DT ORDER POINT TO
DT VIDEO DATA BOX AT 28" (711MM) A.F.F.
DRIVE THRU EXPEDITOR POS
RECEIPT PRINTER
DT AUDIO CONDUIT FROM
DRIVE THRU ORDER POINT
AND DETECTOR LOOP
CONDUIT FROM DT
WINDOW TO DT TIMER
CONTROL DATA JUNCTION
BOXES AT 8'-2" (2490MM)
POWER RECEPTACLE AT
28" (711MM) TO TOP OF
RECEPTACLE A.F.F.
QUAD RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR AND
FUTURE USE
SINGLE DOOR
REFRIGERATOR
DUPLEX CONVENIENCE
OUTLET AT 45" (1143MM) TO
TOP OF RECEPTACLE A.F.F.
DIMENSIONS INDICATE CENTER
MOUNTING POINT FOR MONITOR BASE
*
DRIVE THRU WIRELESS HEADSET
BASE STATION
DRIVE THRU TIMER MONITOR
DRIVE THRU TIMER CONTROL UNIT
POWER AND DATA RECEPTACLES AT 8'-2" (2490MM)
TO TOP OF RECEPTACLES A.F.F.
DEDICATED QUAD RECEPTACLE FOR DRIVE
THRU TIMER MONITOR AND CONTROL UNIT
(2) DEDICATED DUPLEX RECEPTACLE FOR
WIRELESS BASE AND SIGNAL PROCESSOR
WITH CIRCUIT ISOLATED GROUND
2-DATA PORT FOR DT TIMER AND CONTROL UNIT
SINGLE DATA PORT FOR DT AUDIO
(MIC & SPEAKER)
DRIVE THRU TIMER SIGNAL PROCESSOR (TSP)
36" W X 51" H (915MM W X 1295MM H) MIN. FIRE
RATED PLYWOOD BACKER BOARD. FASTEN TO
STRUCTURE. WALL FINISH TO CONCEAL.
FUTURE HHOP CABLING TO HEADSET BASE
STATION FROM J-BOX AT CLG/WALL FOR
EXTERNAL EXTENDED COVERAGE ANTENNA
(FOIO)
2
2 4
HP
-
1
2
HP
-
1
2
CA2-9
HP-39
HP
-
1
4
HP
-
1
2
HP
-
1
4
CEILING
ELEVATION - ELECTRICAL DIAGRAM
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
SOFFIT
POWER AND DATA
RECEPTACLES AT 80"
(2030MM) TO TOP OF
RECEPTACLE A.F.F.
ELEVATION - ELECTRICAL DIAGRAM
PLAN - UPPER ELECTRICAL DIAGRAM
RECEPTACLE FOR
UNDERCOUNTER
REFRIGERATOR
RECEPTACLE FOR
BLENDER(S)*
RECEPTACLE FOR
LABEL PRINTER
AND FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
2-DATA PORT FOR
FUTURE USE
*BLENDER
QUANTITY BASED
ON EQUIPMENT
SCHEDULE
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
UNDERCOUNTER
NITRO
REFRIGERATOR
RECEPTACLE FOR
UNDERCOUNTER
NITRO REFRIGERATOR
RECEPTACLE FOR
NITROGEN
GENERATOR
RECEPTACLE FOR
DPM TABLET
2-DATA PORT FOR
DPM TABLET AND
FUTURE USE
POWER AND DATA
RECEPTACLES AT 28"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
POWER RECEPTACLE
FOR RINSE SINK AT
28" (711MM) TO TOP
OF RECEPTACLE
A.F.F.
UNDERCOUNTER REFRIGERATOR
UNDERCOUNTERNITROGEN
GENERATOR
RECEPTACLE FOR
MILK DISPENSER
RECEPTACLE FOR
ICE DISPENSER
RECEPTACLE FOR
LABEL PRINTER
AND FUTURE USE
2-DATA PORT FOR
LABEL PRINTER
POWER AND DATA
RECEPTACLES AT 68"
(1727MM) TO TOP OF
RECEPTACLE A.F.F.
RECEPTACLE FOR
MILK DISPENSER
POWER AND DATA
RECEPTACLES AT 68"
(711MM) TO TOP OF
RECEPTACLE A.F.F.
PLAN - ELECTRICAL DIAGRAM
2
2222 2
23
4
1
9
A3
-
2
0
23
4
2
1
A3
-
2
2
23
4
1
9
A3
-
1
8
H
17
5
6
4
HP
-
8
B
A2
-
3
2
B
A2
-
3
6
K
HP
-
4
J
HP
-
2
A2
-
1
8
C
A2
-
7
B
A2
-
3
4
A A
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
Revision Schedule
Rev Date By Description
A 12/24/2023 PLAN CHECK
E330
ELECTRICAL
DETAILS
SCALE:3/4" = 1'-0"1 DRIVE THRU
SCALE:3/4" = 1'-0"2 SIREN SYSTEM
STAMP DATE: 12/24/2023
Email: info@peccusa.com
Phone: 909.610.5364
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
Revision Schedule
Rev Date By Description
A 12/24/2023 PLAN CHECK
E500
SINGLE LINE DIAGRAM
TO EXISTING
UTILITY TRANSFORMER
AVAILABLE NOT TO EXCEED
42,000A
(E) SERVICE ENTRANCE EQUIPMENT
400A, 120/208V, 3ɸ-4W, 65kAIC
U.G.P.S.
G
N
(E)
225A
3P
M
(E
)
REFERENCE NOTES
EXISTING PANEL WITH REVISED LOADS. REFER TO PANEL SCHEDULE THIS SHEET.
ALL NEW CIRCUIT BREAKERS INSTALLED WITHIN PANELBOARD SHALL MATCH THE
HIGHEST EXISTING AIC RATED BREAKERS WITHIN PANELBOARD. INSPECTOR TO
VERIFY AT SITE.
THE CONTRACTOR SHALL VERIFY THE METER/MAIN OVERCURRENT PROTECTION
DEVICE'S MANUFACTURER AND PART NUMBER.
CIRCUIT BREAKERS IN ALL DOWNSTREAM PANELS SHALL BE FROM THE SAME
MANUFACTURER OF METER/MAIN OVERCURRENT PROTECTION DEVICE. CIRCUIT
BREAKER AIC RATING SHALL MATCH OR EXCEED SERVICE AVAILABLE FAULT
CURRENT. OTHERWISE, PROVIDE MAIN BREAKER AS SHOWN ON PANEL SCHEDULE
PER MANUFACTURER'S SERIES-RATING CHART.
THE CONTRACTOR SHALL FIELD VERIFY SERVICE EQUIPMENT'S AVAILABLE FAULT
CURRENT BEFORE ISSUING ANY BID. NOTIFY ELECTRICAL ENGINEER IMMEDIATELY
IF MAJOR DISCREPANCIES OCCUR
THE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD TO INDICATE A SERIES
COMBINATION RATING WHICH SHALL BE READILY VISIBLE. CONTRACTOR TO AFFIX
SERIES COMBINATION RATING LABEL SIMILAR TO AS SHOWN ON DETAIL 3/E500.
1
2
3
4
3
2
(E)
MAIN
HP
200A
SCALE:NONE2SINGLE LINE DIAGRAMSCALE:NONE1EATON SERIES RATING CHART
(E)
(E)
225
3P
(E
)
(E)
MAIN
A2
200A
(E)
MLO
A3
225A
(E
)
(E)
400A/3P
EATON
DK
2
ITEM DESCRIPTION U/M
4 PANEL "HP"66.88 KVA
5 PANEL "A2" & "A3"70.62 KVA
6 TOTAL 137.50 KVA
7 AMPS AT 208V-3PH 381.67 AMPS
SCE
259000-
044818
HAZARDOUS VOLTAGE
Series combination system
rated 65K amperes
May cause injury or
equipment damage or
failure.
Identified replacement
components required.
CAUTION
4
1
4
1
4
1
4 4
A
STAMP DATE: 12/24/2023
Email: info@peccusa.com
Phone: 909.610.5364
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
Revision Schedule
Rev Date By Description
A 12/24/2023 PLAN CHECK
E510
PANEL SCHEDULES
SCALE:NONE1PANEL SCHEDULES
A
A
A
A
A
A
STAMP DATE: 12/24/2023
Email: info@peccusa.com
Phone: 909.610.5364
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E600
INTERIOR LIGHTING
COMPLIANCE CERT
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E610
INTERIOR LIGHTING
COMPLIANCE CERT
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
28206-089
09-14-2023
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
Revision Schedule
Rev Date By Description
E620
INTERIOR LIGHTING
COMPLIANCE CERT
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
STAMP DATE: 11/01/2023
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
ABBREVIATIONS
ABOVE FINISHED FLOOR
PLUMBING SYMBOL LEGEND
AFF
AHJ AUTHORITIES HAVING JURISDICTION
APPROX APPROXIMATE
BLDG BUILDING
CLG CEILING
CONST CONSTRUCTION
CW DOMESTIC COLD WATER
CXA COMMISSIONING AGENT
DEG DEGREES
DN
DTL
EC
DOWN
DETAIL
DWG(S) DRAWING(S)
EA EACH
ELECTRICAL CONTRACTOR
ELEC ELECTRICAL
EMER EMERGENCY
EXIST EXISTING
EXT EXTERIOR
FD
FS
F&I
FLOOR DRAIN
FLOOR SINK
FURNISH & INSTALL
FOIC FURNISHED BY OWNER,
INSTALLED BY CONTRACTOR
FOIO FURNISHED BY OWNER,
INSTALLED BY OWNER
FLR
FT
FLOOR
FOOT/FEET
FCO FLOOR CLEANOUT
GC
HR HOUR
HVAC HEATING, VENTILATION, AND AIR
CONDITIONING
HW HOT WATER
HS HANDSINK
HWS HOT WATER SUPPLY
HWR HOT WATER RETURN
LL
LV
LANDLORD
LOW VOLTAGE
MAX MAXIMUM
MC MECHANICAL CONTRACTOR
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL, AND PLUMBING
MFG MANUFACTURER
MIN MINIMUM
MS MOP SINK
NL
NTS
PC
PS
NIGHTLIGHT
NOT TO SCALE
PLUMBING CONTRACTOR
PREP SINK
POC POINT OF CONNECTION
REF REFERENCE
REQ’D REQUIRED
REV REVISION
SHT
SF
TEL
SHEET
SQUARE FEET
SPECS SPECIFICATION(S)
SST STAINLESS STEEL
TELEPHONE
TEMP TEMPORARY
TMV
TYPICAL
UC
TEMPERATURE MIXING VALVE
TW TEMPERED HOT WATER
TYP
UNDER COUNTER
UNO UNLESS NOTED OTHERWISE
V VENT
W SANITARY WASTE
WCO WALL CLEANOUT
WH WATER HEATER
WP WEATHER PROOF
APPLICABLE CODES
CONTRACTOR SHALL COMPLY WITH ALL APPLICABLE STATE CODES
WHETHER INDICATED HEREIN OR NOT.
2022 CALIFORNIA BUILDING STANDARDS CODE:
• PART 1 - CALIFORNIA ADMINISTRATIVE CODE (CAC)
• PART 2 - CALIFORNIA BUILDING CODE (CBC)
• PART 2.5 - CALIFORNIA RESIDENTIAL CODE (CRC)
• PART 3 - CALIFORNIA ELECTRICAL CODE (CEC)
• PART 4 - CALIFORNIA MECHANICAL CODE (CMC)
• PART 5 - CALIFORNIA PLUMBING CODE (CPC)
• PART 6 - CALIFORNIA ENERGY CODE (CENC)
• PART 7 - (CURRENTLY VACANT)
• PART 8 - CALIFORNIA HISTORICAL BUILDING CODE (CHBC)
• PART 9 - CALIFORNIA FIRE CODE (CFC)
• PART 10 - CALIFORNIA EXISTING BUILDING CODE (CEBC)
• PART 11 - CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN)
• PART 12 - CALIFORNIA REFERENCE STANDARDS CODE
FS
M WM
POC
FLOOR SINK
WATER METER
CONNECT TO EXISTING
F. ALL DOMESTIC WATER HEATING, RECIRCULATING, FILTER AND
SOFTENING EQUIPMENT SHALL BE TESTED AND/OR ADJUSTED
AND BALANCED BY THE CONTRACTOR'S TESTING, ADJUSTING
AND BALANCE AGENT (SEE TESTING ADJUSTING AND BALANCING)
OR THE MANUFACTURER'S CERTIFIED STARTUP
REPRESENTATIVE AFTER THE SYSTEM IS VERIFIED TO BE
COMPLETE AND CORRECT BY STARBUCKS CXA IN ACCORDANCE
WITH THE REQUIREMENTS OF THESE DOCUMENTS. SEQUENCES
OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY
OPERATE IN ACCORDANCE WITH THE CONTRACT
REQUIREMENTS. DELIVERABLES: PRELIMINARY, WRITTEN
FUNCTIONAL PERFORMANCE REPORT CONFORMING TO THE
REQUIREMENTS SPECIFIED HEREIN, DOCUMENTING THE
INFORMATION SPECIFIED, ETC. TO THE STARBUCKS CXA
IMMEDIATELY UPON COMPLETION OF THE WORK.
G. CONTRACTOR SHALL INFORM STARBUCKS CXA WHEN
EQUIPMENT IS READY FOR FUNCTIONAL PERFORMANCE
TESTING. ALL EQUIPMENT SHALL BE READY FOR FUNCTIONAL
PERFORMANCE TESTING PRIOR TO STARTING TESTING.
CONTRACTOR SHALL OPERATE EQUIPMENT FOR STARBUCKS
CXA AND VERIFY BY DEMONSTRATION THE CORRECT OPERATION
OF EQUIPMENT, RESPONSE OF SENSORS, AND PROPER
EXECUTION OF HVAC CONTROL AND LIGHTING SEQUENCES;
INCLUDING BUT NOT LIMITED TO, AIR MOVEMENT, TEMPERATURE,
SOUND, AND CONTROL RESPONSE. PROVIDE ANY SECURITY
ACCESS, HARDWARE, SOFTWARE, OR OTHER SUPPORT AS
NEEDED FOR THE STARBUCKS CXA TO EFFICIENTLY WITNESS
AND DOCUMENT ALL EQUIPMENT TESTING. STARBUCKS CXA
WILL RECORD THE EQUIPMENT OPERATION AND RESPONSE TO
TESTING SEQUENCES AND PREPARE A LIST OF ANY
DEFICIENCIES DISCLOSED BY THE FUNCTIONAL PERFORMANCE
TESTS FOR CORRECTION BY THE CONTRACTOR. EQUIPMENT
INCLUDES, BUT IS NOT LIMITED TO, AIR HANDLING UNITS,
ROOFTOP AND SPLIT TYPE, CONDENSING UNITS, EXHAUST FANS,
LIGHTING CONTROLS, ETC. DELIVERABLES: PROVIDE COMPLETED
COPIES OF ALL START UP REPORTS, FILLED OUT ON THE
MANUFACTURER'S FORMS, TO THE STARBUCKS CXA.
H. CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ISSUES
OR DEFICIENCIES DISCLOSED DURING THE FUNCTIONAL
PERFORMANCE TESTING PROCESS. CORRECTIONS SHOULD BE
MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO THE
SYSTEM AND CONSTRUCTION SCHEDULE.
I. CONTRACTOR SHALL BE READILY AVAILABLE FOR ANY RE-
TESTING OF EQUIPMENT DEEMED NECESSARY BY STARBUCKS
CXA DURING INSTALLATION VERIFICATION AND FUNCTIONAL
PERFORMANCE TESTING. CONTRACTOR IS RESPONSIBLE FOR
CORRECTING ANY ISSUES OR DEFICIENCIES FOUND IN THE
SYSTEM DURING ANY AND ALL RE-TESTING. CORRECTIONS
SHOULD BE MADE IN A TIMELY MANNER WITHOUT DISRUPTION TO
THE SYSTEM AND CONSTRUCTION SCHEDULE. DELIVERABLES:
FINAL BALANCE REPORT, DEFICIENCIES LIST NOTING
CORRECTIVE ACTIONS PERFORMED BY CONTRACTOR IN
RESPONSE TO INSTALLATION VERIFICATION AND FUNCTIONAL
PERFORMANCE TEST RESULTS.
J. CONSTRUCTION AND POST CONSTRUCTION TESTING:
ADDITIONAL TESTING MAY BE REQUIRED BY LEED AND OTHER
PROCESSES THAT MAY OCCUR OUT OF SEQUENCE WITH
COMMISSIONING SERVICE. CONTRACTOR SHALL CONDUCT,
DOCUMENT, SUPPORT AND SCHEDULE THIS TESTING AS
DIRECTED BY STARBUCKS CXA.
FCO
WCO WALL CLEANOUT
FLOOR CLEANOUT
GENERAL CONTRACTOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GW GREASE WASTE
S
SHOCK ABSORBER
STRAINER
HB HOSE BIBB
D. INSTALLATION VERIFICATION SHALL BE PERFORMED BY
STARBUCKS CXA. CONTRACTOR SHALL SUPPORT STARBUCKS
CXA INSTALLATION VERIFICATION EFFORTS AS NECESSARY.
PROVIDE ALL ACCESS AND EQUIPMENT NECESSARY FOR
STARBUCKS STAFF TO VERIFY THAT THE EQUIPMENT IS
INSTALLED CORRECTLY.
E. CONTRACTOR SHALL BE READILY AVAILABLE DURING
INSTALLATION VERIFICATION TO CORRECT ANY DEFICIENCIES OR
DEFECTS DISCLOSED BY THE INSTALLATION VERIFICATION
PROCESS. CORRECTIONS SHALL BE MADE IN A TIMELY MANNER
WITHOUT DISRUPTION OF THE CONSTRUCTION SCHEDULE.
CH. V
RV
CHECK VALVE
RELIEF VALVE
BV
GV
BALL VALVE
GATE VALVE
TW
RO
RD
G
RS
TW
RO
G
RD
RS
TEMPERED WATER
REVERSE OSMOSIS WATER
GAS PIPING
REFRIGERANT DISCHARGE PIPING
REFRIGERANT SUCTION PIPING
GW
CD
S OR W
S OR W
V
CD
GW
CW
HW
CWF
CWN
CWS
CWF
CWN
CWS
SANITARY OR WASTE PIPING ABOVE SLAB
SANITARY OR WASTE PIPING BELOW SLAB
CONDENSATE DRAIN
VENT PIPING
HOT WATER PIPING
GREASE WASTE
COLD WATER PIPING
COLD WATER FILTERED
COLD WATER NANO FILTERED
COLD WATER SOFTENED
SYSTEM COMMISSIONING
CONTRACTOR RESPONSIBILITIES FOR BUILDING COMMISSIONING
CONTRACTOR SHALL PROVIDE SUPPORT AND WORK AS SPECIFIED,
NEEDED AND REQUIRED TO CONDUCT AND FACILITATE STARBUCKS
STAFF BUILDING COMMISSIONING EFFORTS. THIS WORK WILL BE
COMPRISED OF THREE DISTINCT EFFORTS:
1) SUPPORT STARBUCKS COMMISSIONING AGENT (CXA) DURING
INSTALLATION VERIFICATION AND CORRECT DISCLOSED
DEFICIENCIES;
2) PERFORM TESTING, ADJUSTING, BALANCING AND SYSTEM STARTUP
AND SUPPORT FUNCTIONAL PERFORMANCE TESTING BY STARBUCKS
CXA;
3) CORRECT DEFICIENCIES DISCLOSED BY FUNCTIONAL PERFORMANCE
TESTING AND SUBMIT REPORTS. CONTRACTOR SHALL PERFORM AND
PROVIDE THE FOLLOWING:
A. SYSTEMS SUBJECT TO COMMISSIONING MAY INCLUDE, BUT ARE
NOT LIMITED TO, DOMESTIC HOT WATER GENERATION.
B. CONTRACTOR SHALL INCLUDE COMMISSIONING ACTIVITIES IN
PROJECT SCHEDULE AND SHOW INTERVALS FOR PERFORMANCE
OF WORK FOR WHICH CONTRACTOR IS RESPONSIBLE AND
INTERVALS FOR WORK PERFORMED BY STARBUCKS CXA.
CONTRACTOR SHALL SHOW RESOURCES FOR PERFORMING ALL
WORK RELATED TO COMMISSIONING ACTIVITIES ON A LINE ITEM
IN THE SCHEDULE OF VALUES.
C. CONTRACTOR SHALL INSTALL EQUIPMENT IN ACCORDANCE WITH
THE MANUFACTURER’S REQUIREMENTS AND ALL CONTRACT
DOCUMENTS. ENSURE THAT ALL EQUIPMENT IS INSTALLED
TOTALLY COMPLETE, AND ACCESSIBLE TO STARBUCKS CXA FOR
INSTALLATION VERIFICATION AND FUNCTIONAL PERFORMANCE
TESTING PRIOR TO THE SCHEDULED START OF INSTALLATION
VERIFICATION.
VALVES
GENERAL
INSTALL VALVES FOR EACH FIXTURE AND ITEM OF EQUIPMENT. PROVIDE
BRAIDED STAINLESS STEEL HOSE (UNLESS OTHERWISE NOTED) BETWEEN
VALVE AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS. LOCATE SHUT-OFF VALVES ADJACENT TO EQUIPMENT
FOR EASY ACCESS SUCH THAT VALVES CAN BE REACHED WITHOUT
MOVING EQUIPMENT. SHUT OFF VALVES TO BE BALL TYPE. VALVES SHALL
BE LISTED/APPROVED FOR USE PER AUTHORITIES HAVING JURISDICTION
(AHJ) AND CODE REQUIREMENTS. PROVIDE VALVE IDENTIFICATION PER
THE PROJECT MANUAL FOR MAIN WATER SERVICE SHUT-OFF AND ANY
OTHER VALVES WHICH ARE NOT CLEARLY EVIDENT WHAT THEY SERVE.
PLUMBING FIXTURES
WATER HEATER
SIZE WATER HEATER PER STARBUCKS STANDARD AND PER AUTHORITIES
HAVING JURISDICTION (AHJ), WHICHEVER IS MORE STRINGENT. PROVIDE
INSTALLATION COMPLETE WITH FITTINGS AS SHOWN IN THE DRAWINGS.
SET HOT WATER TEMPERATURE AT 140° F OR ADJUST AS REQUIRED BY AHJ.
PROVIDE THERMOMETER ON HOT WATER PIPE LEAVING WATER HEATER.
WATER FILTRATION
STARBUCKS WATER FILTRATION VENDOR WILL PROVIDE FILTRATION
SYSTEM. CONTRACTOR SHALL CONFIRM WITH STARBUCKS CONSTRUCTION
MANAGER WHETHER VENDOR OR PLUMBING CONTRACTOR IS TO INSTALL
FILTRATION SYSTEM. PROVIDE AND COORDINATE INSTALLATION COMPLETE
WITH ALL PIPING, FITTINGS, AND EQUIPMENT AS INDICATED ON THE
DRAWINGS.
CONNECTIONS
THE PLUMBING CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS TO
EQUIPMENT INCLUDING REQUIRED MATERIAL SUCH AS PIPING, VALVES,
FILTERS, TRAPS, CHECKS VALVES, VACUUM BREAKERS, AND FLEXIBLE AND
RIGID TUBING.
SCHEDULES
REFER TO SCHEDULES ON DRAWINGS FOR A DESCRIPTION OF LISTED ITEMS
AND FURNISH ANY AND ALL PLUMBING FIXTURES LISTED AS "GC". ANY
DISCREPANCIES ABOUT WHO IS TO PROVIDE PLUMBING FIXTURES IN THE
SCHEDULE SHALL BE BROUGHT TO STARBUCKS ATTENTION FOR
CLARIFICATION.
SUPPLIES.
INSTALL ALL FIXTURES LISTED REGARDLESS OF WHO
DISHWASHER
G.C. TO FURNISH AND INSTALL POWER CORD FOR DISHWASHER PER
JURISDICTIONAL REQUIREMENTS.IF EQUIPMENT IS SPECIFIED AS
HOBART ADVANSYS, THE UNIT IS TO BE PLUMBED WITH COLD, NON-
FILTERED WATER.IF THE WATER FILTRATION SYSTEM IS A PENTAIR
CONFIGURATION II OR III, THEN THE COLD, NON-FILTERED WATER MUST
ALSO BE SOFTENED.
INSULATION
WATER PIPING
PROVIDE THERMAL INSULATION PER THE SPECIFICATIONS.
SAFETY COVERS
FURNISH AND INSTALL SPECIFIED NO SCALD SAFETY COVERS WITH
INSULATED FOAM LINER AND TAMPER PROOF STRAP AT ALL EXPOSED ADA
SINK P-TRAPS AND WATER SUPPLIES AND AS REQUIRED BY JURISDICTION .
PIPING
CONDENSATE DRAINAGE PIPING
THE PLUMBING CONTRACTOR SHALL PROVIDE CONDENSATE DRAINS
FOR AIR HANDLING UNITS AND STARBUCKS EQUIPMENT (REFER TO
SCHEDULE). CONDENSATE DRAINAGE PIPING SHALL BE TYPE "M"
COPPER TUBING WITH WROUGHT COPPER SWEAT FITTINGS JOINED
WITH 50/50 SOLDER.
TESTING
ALL PIPES SHALL BE TESTED BY AN APPROVED METHOD BEFORE THEY
ARE
BACKFILLED OR CONCEALED. AFTER TESTING IS COMPLETE, THE
PLUMBING
CONTRACTOR SHALL DISINFECT THE POTABLE WATER SYSTEM AS
REQUIRED BY LOCAL AUTHORITY. TEST WATER PURITY ACCORDING TO
LOCAL REQUIREMENTS AND SUBMIT CERTIFIED TEST RESULTS TO
ENGINEER FOR REVIEW AND APPROVAL.
CARBONATION
IF APPLICABLE TO PROJECT SCOPE FOR CBE STATION, STARBUCKS
CARBONATION VENDOR WILL PROVIDE AND INSTALL EQUIPMENT, CO2
TANKS AND FITTINGS. STARBUCKS SHALL PROVIDE AND CONTRACTOR
SHALL INSTALL CO2 TANK MOUNTING BRACKET, PROTECTIVE SHELVING
UNIT AND CO2 GAS TUBING AS SHOWN ON DRAWINGS AND PER
MANUFACTURER’S INSTRUCTIONS. MAXIMUM TUBING LENGTH
INCLUDING COILED ENDS IS 100 FT (30 M) AND MAXIMUM BEND IS TO 3
INCH (75 MM) MINIMUM RADIUS. ROUTE CO2 TUBING PREFERABLY
THROUGH WALL AND/OR CEILING CAVITIES, WITHOUT KINKS AND SO AS
TO NOT TOUCH ANY HOT SURFACE (BALLAST, STEAM PIPE, ETC.) OR RUB
AGAINST A SHARP EDGE THAT MAY ABRADE OR CUT TUBING. ALL HOLES
MUST BE SEALED WITH A GROMMET OR ESCUTCHEON. TUBING IS TO BE
SECURED TO APPROPRIATE PERMANENT SURFACES TO KEEP IT OFF THE
FLOOR OR CABINET BOTTOMS AND AWAY FROM OTHER EQUIPMENT.
LABEL BOTH ENDS OF TUBING AND REGULARLY AT TEN (10) FOOT
INTERVALS ALONG ROUTE AS “CO2.”
NITROGENATION
STARBUCKS NITROGENATION VENDOR WILL PROVIDE AND INSTALL
EQUIPMENT AND FITTINGS IF APPLICABLE TO PROJECT SCOPE FOR
NITRO STATION. GENERAL CONTRACTOR SHALL COORDINATE NITRO
SYSTEM INSTALLATION WITH STARBUCKS VENDOR.
GENERAL PLUMBING NOTES
1. PLUMBING CONTRACTOR SHALL COORDINATE WITH THE GENERAL
CONTRACTOR TO PATCH AND REPAIR ALL EXISTING WALLS, FLOORS,
CEILINGS OR OTHER SURFACES IDENTIFIED TO REMAIN THAT MAY
BECOME DAMAGED DURING THE COURSE OF WORK.
2. EXPOSED/SURFACE MOUNTED PIPING IS ONLY ALLOWED IN THE BAR
AREA UNDER COUNTERTOPS, WHERE IT DOES NOT OBSTRUCT
CABINETS/DEVICES AND WHERE APPROVED BY STARBUCKS
CONSTRUCTION MANAGER. IF ROUTED THROUGH CABINETS, IT
SHALL BE ROUTED TO MAXIMIZE STORAGE SPACE AND BE
PROTECTED FROM DAMAGE.
3. DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL INTENT OR
ARRANGEMENT OF SYSTEM(S). FURNISH AND INSTALL ALL
COMPONENTS NEEDED WHETHER INDICATED OR NOT TO PROVIDE A
COMPLETE AND OPERATING SYSTEM. OVERALL CASEWORK
COMPONENT DIMENSIONING ON PLUMBING DETAILS ARE SHOWN
FOR REFERENCE AND COORDINATION ONLY.
4. CONTRACTOR TO VERIFY ALL DIMENSIONS, INCLUDING CLEARANCES
REQUIRED BY OTHER TRADES, AND NOTIFY STARBUCKS
CONSTRUCTION MANAGER OF ANY DISCREPANCIES PRIOR TO
PROCEEDING WITH THE WORK. ALL DIMENSIONS ARE TO THE FACE
OF THE FINISHED SURFACE UNLESS NOTED OTHERWISE. ALL
DIMENSIONS TO BE TAKEN FROM ACTUAL BUILDING DIMENSIONS.
5. THE PLUMBING CONTRACTOR SHALL COORDINATE PLUMBING WORK
WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS AND
SPECIFICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER
DRAWINGS. SEE ARCHITECTURAL DRAWINGS FOR FIXTURES IN
CASEWORK AND PLUMBING DETAILS. SEE THE PROJECT MANUAL
FOR PLUMBING SPECIFICATION SECTIONS.
6. ALL PIPING AND/OR PLUMBING DEVICES SHALL BE SUPPORTED FROM
STRUCTURE (NOT FROM HVAC DUCTS OR OTHER PIPES/CONDUITS).
7. WHEN BUNDLING SEVERAL INDIRECT WASTE LINES TO DRAIN INTO
FLOOR SINK, A UNISTRUT IS REQUIRED FOR SECURING AND BRACING
ALL LINES ABOVE THE DRAIN.
8. FURNISH AND INSTALL ALL NEEDED DRAIN LINES PER CODE (NOT ALL
SHOWN).INSTALL DRAINS AT 2% SLOPE WHERE POSSIBLE WITHOUT
DIPS OR SAGS. ALL INDIRECT DRAINS SHALL RUN SEPARATELY
FROM EACH OTHER TO INDIRECT DRAIN RECEPTOR AND SHALL
TERMINATE WITH AN AIR GAP PER CODE.
9. FURNISH AND INSTALL WALL CLEANOUTS AT ALL SINKS AND AS
NEEDED PER CODE (NOT ALL SHOWN).
10. INSULATE ICE BIN DRAINAGE PIPES PER THE REQUIREMENTS IN THE
PROJECT MANUAL.
GENERAL NOTES
SCOPE
THE INTENT OF THE PROJECT MANUAL AND THE DRAWINGS IS TO
PROVIDE A COMPLETE AND FULLY OPERATIONAL PLUMBING SYSTEM.
THE CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, AND
EQUIPMENT RELATED TO THE INSTALLATION OF THE PLUMBING WORK.
SITE EXAMINATION
THE CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE
FIXTURES, EQUIPMENT, AND PIPING WILL BE INSTALLED AND WILL
REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION
OF THE PLUMBING WORK.
STANDARDS
EQUIPMENT AND MATERIALS SHALL CONFORM WITH THE APPROPRIATE
PROVISIONS OF LISTING STANDARD IN EFFECT AS APPLICABLE TO EACH
INDIVIDUAL UNIT OR ASSEMBLY.
CODES
ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL
APPLICABLE PROVINCIAL AND LOCAL CODES AND ORDINANCES. IN CASE
OF CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS AND THE
CODES AND ORDINANCES, THE HIGHEST STANDARD SHALL APPLY. THE
CONTRACTOR SHALL SATISFY CODE REQUIREMENTS AS A MINIMUM
STANDARD WITHOUT ANY EXTRA COST TO STARBUCKS.
PERMITS AND FEES
THE CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES,
AND INSPECTIONS NECESSARY TO COMPLETE THE PLUMBING WORK.
WARRANTY
THE CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO
BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD
OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY
STARBUCKS AND WILL REPAIR OR REPLACE ANY DEFECTIVE WORK
PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING
WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS
AND WORKMANSHIP.
LANDLORD REQUIREMENTS
PRIOR TO BID: THE CONTRACTOR SHALL COORDINATE WITH LANDLORD /
BUILDING OWNER FOR ANY CONSTRUCTION REQUIREMENTS.
CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH
REQUIREMENTS AND ADHERE TO THEM. WHERE LANDLORD / BUILDING
OWNER REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE
PLANS. LANDLORD / BUILDING OWNER REQUIREMENTS SHALL GOVERN.
WATER HAMMER ARRESTORWHA
PLUMBING GENERAL
NOTES & LEGENDS
P-001
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
A 12/21/23 PLAN CHECK COMMENT - 1
11. ABS AND PVC PIPING EXPOSED TO SUNLIGHT SHALL BE PROTECTED BY
WATER BASED SYNTHETIC LATEX PAINTS. (CPC 906.1).
12. SUSPENDED PIPING SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED
THOSE SHOWN IN TABLE 313.3. 2022 CPC SEC.313.3.
A
NOTE: WATER PIPING INSULATION SHOULD BE AS PER TABLE 120.3-A OF THE
2022 CALIFORNIA ENERGY CODE.
A
5
A
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
PLUMBING SCHEDULES
& CALCULATIONS
P-002
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
ELECTRIC WATER HEATER SCHEDULE (EXISTING)
TAG QTY MANUFACTURE MODEL CAPACITY
(GALLON)
ELEMENT
WATTAGE
RECOVERY
@90°F RISE
(GPH)
VOLTAGE(V)
CONNECTION OPERATING
WEIGHT
(LBS)
CW HW
(E) WH-1 1 RHEEM ES50-18-G-1 50 18,000 83 208 1-1/4"1-1/4"320
NOTE: ADDITIONS OR ALTERATIONS OR NEW PLUMBING FIXTURES AND
FITTINGS SHALL NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATES
SPECIFIED IN SECTION 5.303.
MAXIMUM FLOW RATE
NONRESIDENTIAL LAVATORY FAUCETS 0.4 GPM @ 60 PSI
KITCHEN FAUCETS 1.6 GPM @ 60 PSI
METERING FAUCETS 0.2 GALLONS/CYCLE
WATER CLOSETS 1.28 GALLONS/FLUSH
DC
5030
61-113
B
12-32
5010
A
1-11
5005
FIXTURE UNITS
HYDROTROL
J.R. SMITH
WHA SYMBOL
33-60
5020
EQUAL
OR APPROVED
WATER HAMMER ARRESTER SCHEDULE
5
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
PLUMBING SCHEDULES
& CALCULATIONS
P-003
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
A 12/21/23 PLAN CHECK COMMENT - 1
MARK
WCO
FCO
GCO
TMV
NOTES:
1. CONTRACTOR TO VERIFY THAT ALL PLUMBING FIXTURES ARE FOR INSTALLATION ON EXPOSED SLAB.
2. ALL FIXTURES ARE SUBJECT TO TENANT/ARCHITECT APPROVAL.
3. REFER TO ARCHIECT PLANS FOR COMPLETE LIST OF PLUMBING FIXTURES.
FIXTURE
W
WALL
CLEANOUT
FLOOR
CLEANOUT
GRADE
CLEANOUT
THERMOSTATIC
MIXING VALVE
SEE -
PLANS
SEE -
PLANS
SEE -
PLANS
--1/2"1/2"
--
--
--
ZURN WALL CLEANOUT MODEL Z1441-VP, DURA-COATED CAST IRON BODY, GAS AND WATERTIGHT,
VANDAL PROOF SCREWS, OR EQUIVALENT. COORDINATE FINAL LOCATIONS AND FINISH WITH
ARCHITECT.
ZURN FLOOR CLEANOUT MODEL Z1400-VP, ADJUSTABLE LEVELING, GAS AND WATERTIGHT, VANDAL
PROOF SCREWS, OR EQUIVALENT. COORDINATE FINAL LOCATIONS AND FINISH WITH ARCHITECT.
ZURN GRADE CLEANOUT MODEL Z1400-DC, HEAVY DUTY, ADJUSTABLE LEVELING, GAS AND
WATERTIGHT, VANDAL PROOF SCREWS, OR EQUIVALENT. COORDINATE FINISH WITH ARCHITECT.
SYMMONS MAXLINE THERMOSTATIC MIXING VALVE MODEL 7-210-CK-D, W/ INTEGRAL CHECK VALVES
AND WALL MOUNTING BRACKET, ASSE 1017 AND ASSE 1070 COMPLIANT. PROVIDE DIAL TYPE
THERMOMETER ON TEMPERED WATER LINE AT TMV OULET AND SET @ 110°F.
FIXURE ROUGH-IN
DESCRIPTION
ACCESSORY SCHEDULE
V CW HW
TY
P
E
"
K
"
C
O
P
P
E
R
PE
X
TY
P
E
"
M
"
C
O
P
P
E
R
TY
P
E
"
L
"
C
O
P
P
E
R
DW
V
C
O
P
P
E
R
SC
H
1
0
S
T
A
I
N
L
E
S
S
SC
H
4
0
B
L
A
C
K
S
T
E
E
L
NO
-
H
U
B
C
A
S
T
I
R
O
N
GR
O
O
V
E
D
T
Y
P
E
L
C
O
P
P
E
R
PIPE MATERIAL SCHEDULE
LEGEND
B = BARE PIPE
I = INSULATED
H = HEAT TRACED
SERVICE
DOMESTIC WATER
DOMESTIC HOT WATER
NATURAL GAS
MEDIUM PRESSURE GAS
WASTE
VENT
STORM DRAIN
OVERFLOW DRAIN
TRAP PRIMER
CONDENSATE
GREASE WASTE
ABOVE GRADE
ABOVE GRADE
BELOW GRADE
LOCATION
BELOW GRADE
INSIDE, 4" & SMALLER
INSIDE, 5" & LARGER
INSIDE, 4" & SMALLER
INSIDE, 5" & LARGER
ABOVE GRADE
ABOVE GRADE
BELOW GRADE
INSIDE
BELOW GRADE
ABOVE INSIDE
BELOW GRADE
INSIDE
BELOW GRADE B
B
B
B
B
B
B
I
I
B
N/A
B
B
B
B
N/A
N/A
MATERIALS ADDITIONAL COMMENTS
MARK
GI-1
NOTES :
1. 4" PLAIN END INLET / OUTLET.
2. MAXIMUM OPERATING TEMPERATURE: 140 F CONTINUOUS
3. BUILT-IN FLOW CONTROL OR PROVIDE FLOW CONTROL DEVICE AS PER THE PLAN.
4. COVER PLACEMENT ALLOWS FULL ACCESS TO TANK FOR PROPER MAINTENANCE.
5. ENGINEERED INLET AND OUTLET DIFFUSERS ARE REMOVABLE TO INSPECT / CLEAN PIPING.
6. INTEGRAL AIR RELIEF / ANTI-SIPHON.
7. SIZING AND MODEL NUMBER ARE BASED ON TENANT'S REQUIREMENT.
31 GALLONS 125 GALLONS
FLOW RATE
(GPM)LOCATION
75 REFER TO SHEET PS-100
FOR EXACT LOCATION.
PIPE
CONNECTION
4 INCH
MANU
SCHIER GB-75 47" X 33" X 40"
HYDRO-MECHANICAL GREASE INTERCEPTOR SCHEDULE
WEIGHT (LBS)
190
SAMPLING BOX SPECIFICATION
PROVIDE SCHIER MAKE SAMPLE BOX MODEL SV10
FLOW CONTROL DEVICE SPECIFICATION
PROVIDE ENDURA MAKE FLOW CONTROL
DEVICE MODEL 4044275A OR EQUALS BY
OWNER APPROVAL.
SOLIDS
CAPACITY
LIQUID
CAPACITY MODEL SIZE ( L X W X H)
INSTALL 75 GPM (SCHIER GB-75) GREASE
INTERCEPTOR WITH SAMPLING BOX.
SC
H
E
D
U
L
E
4
0
P
V
C
A
5
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
BACKBAR
WORKROOM
CAFE
PARTNER
REST
AREA
MANAGER
AREA
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
22558
WC-1
LAV-1
10116
21352
(E) WFS-1
10477
10804
13700
(E) DW-1
3CS-1
10152
10549DS-1
22558
WC-1
LAV-1
10116
21352
14688
13588
HS-1
10152
10549
DS-1
10597
HS-1
10153
10215
17565
RS-1
10153
11003
CRS-1
22642
22768
10153
11003
CRS-1
22642
22768
10153
11003
CRS-1
22642
22768
6
(E) EM-1
6
(E) EM-1
10597
HS-1
IM-1
TP5
FD-1
TP
5
FD-1
6
(E) EM-1
3
3
4
3
CW2"
3
1
CFW1/2"
BP-1
(E) WH-1
(E) RO-1
(E) WATER
SOFTENER
RCP-1
HW
1
2
0
°
3/
4
"
CW
1-
1
/
4
"
CW1/2"
HW 120°3/4"
CW1-1/4"
HWR3/4"
CW
1-
1
/
4
"
3/
4
"
HW
1
4
0
°
HW
1
2
0
°
3/
4
"
CF
W
1/
2
"
HW
R
3/
4
"
1-
1
/
2
"
3/
4
"
HW
1
4
0
°
HW
1
2
0
°
3/
4
"
CF
W
3/
4
"
CW CW
1/
2
"
HW
1
2
0
°
1/
2
"
1"
HW
1
2
0
°
3/
4
"
CW
3/4"
HW 120°3/4"CW3/4"
HW 120°3/4"CW
CF
W
3/
4
"
2
7
IM-1
2
DB-1
6
CW1/2"
3
8
10922
10995
MS-1
23442
CW HW
1
2
0
°
3/
4
"
1-
1
/
4
"
HB-1
HB-1
23335
9
9
1/4" = 1'-0"1PLUMBING WATER PLAN
PLUMBING
WATER PLAN
ABBREVIATION LEGEND:
3CS-1 = 3-COMPARTMENT SINK
CRS-1 = COUNTERTOP RAINSE SINK
DB-1 = DUAL BREWER
DS-1 = DUMP SINK
DW-1 = DISH WASHER
EM-1 = EXPRESSO MACHINE
FD-1 = FLOOR DRAIN
FS-1 = FLOOR SINK
HS-1 = HAND SINK
IM-1 = ICE MACHINE
LAV-1 = LAVATORY
MS-1 = MOP SINK
RO-1 = REVERSE OSMOSIS WATER
FILTER
RS-1 = RINSE SINK
WC-1 = WATER CLOSET
WFS-1 = WATER FILLING STATION
WH-1 = WATER HEATER
P-100
N
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
A 12/21/23 PLAN CHECK COMMENT - 1
1 CONNECT TO 2" CW LINE. CONTRACTOR TO VERIFY EXACT LOCATION, SIZE OF MAIN SUPPLY
LINE TO TENANT SPACE.
BACKFLOW PREVENTER SHALL BE ADDED WITH VALVE .
PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-2) SET AT 108° F TEMPERATURE TO
MAINTAIN.
PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-1) SET AT 120° F TEMPERATURE TO
MAINTAIN.
1/2" CW TO TRAP PRIMER MODEL NO: TP300T FROM WATTS MANUFACTURER.
PROVIDE ASSE 1012 APPROVED DUAL CHECK VALVE WITH ATMOSPHERIC VENT FOR EXPRESSO
MACHINE AND DUAL BREWER.
COLD WATER FROM WATER SOFTENER TO R.O. CONTROL SYSTEM AND WATER HEATER.
1/2" CW & 1/2" CFW TO OVEN COMBI.
PROVIDE ASSE 1010 OR PDI-WH 201 APPROVED WATER HAMMER ARRESTOR DEVICE FOR ALL
QUICK-ACTING WATER VALVES.
PLUMBING PLAN KEYNOTES
GENERAL NOTES
2
3
4
5
6
7
8
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY
SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO
REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO
RENOVATED SYSTEMS.
9
A
A
A
5
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
ABBREVIATION LEGEND:
3CS-1 = 3-COMPARTMENT SINK
CRS-1 = COUNTERTOP RAINSE SINK
DB-1 = DUAL BREWER
DS-1 = DUMP SINK
DW-1 = DISH WASHER
EM-1 = EXPRESSO MACHINE
FD-1 = FLOOR DRAIN
FS-1 = FLOOR SINK
HS-1 = HAND SINK
IM-1 = ICE MACHINE
LAV-1 = LAVATORY
MS-1 = MOP SINK
RO-1 = REVERSE OSMOSIS WATER
FILTER
RS-1 = RINSE SINK
WC-1 = WATER CLOSET
WFS-1 = WATER FILLING STATION
WH-1 = WATER HEATER
P-200
PLUMBING
WASTE PLAN
1/4" = 1'-0"1PLUMBING WASTE PLAN
N
1
PLUMBING PLAN KEYNOTES
GENERAL NOTES
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY
SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO
REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO
RENOVATED SYSTEMS.
2
3
4
5
INDIRECTLY DRAIN FIXTURE TO NEAREST FLOOR SINK. TERMINATE W/ 2" AIR GAP.
3" WASTE LINE FROM 3-COMPARTMENT SINK TERMINATE TO THE FLOOR SINK WITH AIR GAP
CONNECTION.
3" VENT THRU ROOF.
3/4" TEMPERATURE AND RELIEF DRAIN TERMINATE INTO BUILDING.
SEE PS-100 PLUMBING PLAN FOR CONTINUATION.
3" GREASE VENT LINE UP TO ROOF AND TERMINATE ON THE ROOF WITH WEATHER
PROTECTIVE CAP.
6
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
A 12/21/23 PLAN CHECK COMMENT - 1
5
BACKBAR
WORKROOM
CAFE
PARTNER
REST
MANAGER
AREA
EMPLOYEE
UNISEX
RESTROOM
CUSTOMER
UNISEX
RESTROOM
10477
10804
13700
3CS-1
2
(E) WFS-1
1
LAV-1
10116
21352
FD-1
22558
WC-1
(E) DW-1
1
10152
10549
DS-1
22558
WC-1
FD-1
LAV-1
10116
21352
IM-1
14688
13588
HS-1
10922
10995
MS-1
(E) WH-1
10597
HS-1
23442
IM-1
10153
10215
17565
RS-1
(E) EM-1
1
10153
11003
CRS-1
22642
22768
10152
10549
DS-1
5
2% SLOPE
4" SS
10597
HS-1
FCO
2%
S
L
O
P
E
4"
S
S
2%
S
L
O
P
E
4"
S
S
2% SLOPE
2" SS
2% SLOPE
2" SS
2% SLOPE
4" SS
2% SLOPE
4" SS
2% SLOPE
2" SS
2" V
2"
V
2" V
2"
V
2"
V
2" V 2" V
2"
V
2"
V
3
3
4
2 WAY CO
2" SS
4" S
S
10153
11003
CRS-1
22642
22768
10153
11003
CRS-1
22642
22768
(E) EM-1
1
(E) EM-1
1
4"
S
S
2%
S
L
O
P
E
3"
G
W
2" GW
2" GW
2" GW
3" GW
3"
G
W
2"
S
S
2"
G
W
10594
10594
2% SLOPE
2"
V
5
5
5
6
3" V B.G.
3" V B.G.
2% SLOPE
4" GW
FCO
2%
S
L
O
P
E
3"
G
W
2%
S
L
O
P
E
4"
G
W
2% SLOPE
4" GW
FCO
FCO
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
(E) DW-1x3/4"
(1.5)
3CS-2x3/4"
(3)
(E) WFS-3x1/2"
(1.5)
LAV-2x1/2"
(1)
WC-1x1-1/4"
(5)
IM-1x1/2"
(0.5)
LAV-2x1/2"
(1)
WC-1x1-1/4"
(5)
DS-2x1/2"
(1.5)
(E) WATER SOFTENER
1
BP-1
TMV-1
3
(E) WH-1
MS-2x3/4"
(3)
CRS-3x1/2"
(1.5)
(E) EM-1x1/2"
(0.5)
CRS-3x1/2"
(1.5)
(E) EM-1x1/2"
(0.5)
CRS-3x1/2"
(1.5)
HS-2x1/2"
(1.5)
RS-3x1/2"
(1.5)
RCP-1
DUAL CHECK
VALVE
DB-1x1/2"
(0.5)
DS-2x1/2"
(1.5)
HS-2x1/2"
(1.5)
IM-1x1/2"
(0.5)
HS-2x1/2"
(1.5)
1-1/4" CW
(8.5)
3/4" HWR
1-1/4" CW
(5)
3/4" HW 120°
3/4" HW 120°
1-1/4" CW
(5)
TMV-2
2
TMV-2
2
TMV-2
2
TMV-2
2
TMV-2
2
1/2" CW
(1.5)
1/2" HW120°
1/2" CW
(1)
1/2" HW120°
1/2" CW
(1.5)
1/2" HW120°
1/2" CFW
3/4" CW
(3)
3/4" HW140°
3/4" HW140°
1/2" CW
(1.5)
1/2" HW120°
1/2" CFW
1/2" CFW
1/2" CFW
1/2" CFW
1/2" CW
(0.5)
1/2" CW
(1.5)
1/2" HW120°
1/2" CFW
1/2" CW
(1.5)
1/2" CW
(1.5)
1/2" HW120°1" CW
(9)
3/4" HW120°
1/2" CFW
1/2" CW
(1.5)
1/2" HW120°
1/2" CFW
1/2" CW
(1.5)
1/2" HW120°
1/2" CFW
1/2" CW
(1.5)
1/2" HW120°
1/2" CW
(1.5)
1/2" HW120°
3/4" CW
(3.5)
3/4" HW120°
1/2" CFW
1/2" CFW
3/4" CFW
3/4" CW
(7)
3/4" HW120°
1" CW
(10.5)
3/4" HW120°
1/2" CW
(1.5)
1/2" HW120°
3/4" CW
(3)
(E) RO-1
3/4" HW140°
3/4" CFW
1" CW
(12)
1/2" CFW
1/2" CW
(0.5)
1-1/4" CW
(8.5)3/4" HW 120°
3/4" HW120°
1-1/4" CW
(10)
3/4" HW120°
1-1/4" CW
(13)
3/4" HW140°
1" HW120°
1-1/4" CW
(14.5)
3/4" HW140°
1-1/2" CW
(23)
3/4" HW120°
1-1/2" CW
(25)
3/4" HW140°
2" CW
(38)
2" CW
(41.5)
3/4" HWR
4
DUAL CHECK
VALVE
(E) EM-1x1/2"
(0.5)
DUAL CHECK
VALVE
DUAL CHECK
VALVE
1/2" HW120°
1/2" CW
OVEN COMBI - 2x1/2"
(0.5)
HB-1x3/4"
(1)
3/4" CW
(1)
HB-1x3/4"
(2.5)
3/4" CW
(2.5)
1-1/4" CW
(5)
5
5
PLUMBING WATER ISOMETRIC
PLUMBING WATER
ISOMETRIC
ABBREVIATION LEGEND:
3CS-1 = 3-COMPARTMENT SINK
CRS-1 = COUNTERTOP RAINSE SINK
DB-1 = DUAL BREWER
DS-1 = DUMP SINK
DW-1 = DISH WASHER
EM-1 = EXPRESSO MACHINE
FD-1 = FLOOR DRAIN
FS-1 = FLOOR SINK
HS-1 = HAND SINK
IM-1 = ICE MACHINE
LAV-1 = LAVATORY
MS-1 = MOP SINK
RO-1 = REVERSE OSMOSIS WATER
FILTER
RS-1 = RINSE SINK
WC-1 = WATER CLOSET
WFS-1 = WATER FILLING STATION
WH-1 = WATER HEATER
P-400
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
A 12/21/23 PLAN CHECK COMMENT - 1
NTS 1
GENERAL NOTES
PLUMBING PLAN KEYNOTES
1 CONNECT TO 2" CW LINE. CONTRACTOR TO VERIFY EXACT LOCATION, SIZE OF MAIN SUPPLY
LINE TO TENANT SPACE.
PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-2) SET AT 108° F TEMPERATURE TO
MAINTAIN.
PROVIDE ASSE 1070 THERMOSTATIC MIXING VALVE (TMV-1) SET AT 120° F TEMPERATURE TO
MAINTAIN.
1/2" CW & 1/2" CFW TO OVEN COMBI.
PROVIDE ASSE 1010 OR PDI-WH 201 APPROVED WATER HAMMER ARRESTOR DEVICE FOR ALL
QUICK-ACTING WATER VALVES.
2
3
4
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY
SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO
REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO
RENOVATED SYSTEMS.
5
A
A
A
5
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
PLUMBING WASTE AND VENT ISOMETRIC
PLUMBING WASTE
&VENT ISOMETRIC
ABBREVIATION LEGEND:
3CS-1 = 3-COMPARTMENT SINK
CRS-1 = COUNTERTOP RAINSE SINK
DB-1 = DUAL BREWER
DS-1 = DUMP SINK
DW-1 = DISH WASHER
EM-1 = EXPRESSO MACHINE
FD-1 = FLOOR DRAIN
FS-1 = FLOOR SINK
HS-1 = HAND SINK
IM-1 = ICE MACHINE
LAV-1 = LAVATORY
MS-1 = MOP SINK
RO-1 = REVERSE OSMOSIS WATER
FILTER
RS-1 = RINSE SINK
WC-1 = WATER CLOSET
WFS-1 = WATER FILLING STATION
WH-1 = WATER HEATER
P-401
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
A 12/21/23 PLAN CHECK COMMENT - 1
1
GENERAL NOTES
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT
NECESSARILY SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK
TO REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW
TO RENOVATED SYSTEMS.
PLUMBING PLAN KEYNOTES
1 CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION ,
INCLUDING EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR
THE ADDED FIXTURE LOAD FROM THIS T.I..
NTS
5
DS(2)
WCO
WC(4)
FD(2)
LAV-1(1)
WCO
WCOWCO
FS
3CS(6)
(E) WFS
FS
(E) DW(2)
LAV-1(1)
WCO
FD(2)
WC(4)
WCO
WCO
3" VTR
FS
IM(2)
WCO
WCO
WCO
HS(2)
FS
IM(2)
WCO
WCO
DS(2)
WCO
WCO
HS(2)
WCO
MS(3)
FS
RS(2)
WCO
FS(2)
WCO
FCO
3" VTR
FS
CRS(2)
FS
CRS(2)
HS(2)
WCO
WCO
WCO
1
2" GW
(2)
2% S
L
O
P
E
2" GW
(2)
2" GW
(2)
3" GW
(3)
2" GW
(2)
2" GW
(2)
2" GW
(2)
4" GW
(17)
4" SS
(7)
2% S
L
O
P
E
2" SS
(1)
4" SS
(4)4" SS
(2)
4" SS
(6)
4" SS
(7)
2" SS
(3)
2" SS
(1)
2% S
L
O
P
E
2" SS
(2)2% S
L
O
P
E
2" SS
(2)
2" SS
(4)
2% S
L
O
P
E
2" SS
(2)
2" SS
(2)
2" SS
(6)
2% S
L
O
P
E
4" SS
(9)
4" SS
(16)
4" SS
(22)
2" SS
(2)
2% S
L
O
P
E
4" SS
(24)
2" SS
(2)
2" SS
(2)
2" SS
(2)
2% S
L
O
P
E
2 WAY CO
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2" V
2% S
L
O
P
E
2" GW
(6)
3" GW
(7)
3" GW
(10)
3" GW
(8)
4" SS
(26)
2% S
L
O
P
E
4" SS
2% S
L
O
P
E
2" V
2" V
2% S
L
O
P
E
3" GW
(6)
GI-1
SAMPLE BOX
(SV-10)
SCHIER GB-75
3" VTR
3" V B.G.
3" VTR
FCO
3" GW
(4)
FCO
2% S
L
O
P
E
3" GW
(2)
3" GW
(8)
3" GW
(21)
2% S
L
O
P
E
2% S
L
O
P
E
2% S
L
O
P
E
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
CONFIGURATION III
WATER FILTRATION
SYSTEM. SEE
CONFIGURATION III, R.O.
AND SOFTENER DETAIL
FOR MORE
INFORMATION.
R.O. PERMEATE
TANK
FRP ENCLOSED
6"
(
1
8
3
0
M
M
)
M
I
N
.
CL
E
A
R
4'
-
2
"
(
1
2
7
0
M
M
)
BA
C
K
E
R
2'
-
6
"
(
7
6
5
M
M
)
7'
-
2
"
(
2
1
8
5
M
M
)
NOTE:
1. KEEP CLEAR AT BACKWALL FOR CHEMICAL DISPENSING SYSTEM COMPONENTS, TO BE INSTALLED BY SYSTEM VENDOR. REFER TO
POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION
2'
-
0
"
(
6
1
0
M
M
)
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
STRAP UNITS PER LOCAL
CODE REQUIREMENTS
PROVIDE MOISTURE-
RESISTANT BLOCKING TO
STRUCTURE BEHIND
WALL FINISH AT THESE
AREAS. REFER TO ITEM
SPECIFICATIONS FOR
PLUMBING SCOPE;
COORDINATE INSTALL
WITH FILTER VENDOR.
FRP ENCLOSED
HOT WATER TANK. SEE
SPECIFICATIONS AND
WATER HEATER TANK
DETAIL FOR MORE
INFORMATION.
MOP HOLDER
3'
-
0
"
(
9
1
5
M
M
)
5'
-
0
"
(
1
5
2
5
M
M
)
HOSE CLIP
HOT AND COLD
WATER SUPPLY
FOR FAUCET
MOP SINK
SEE NOTE 1
BELOW
SEE NOTE 1
BELOW
2'-0"(610MM)
6'-0"(1830MM) MIN.
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
WATER BOOSTER PUMP
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FRP ENCLOSED
9'
-
6
"
(
2
8
9
5
M
M
)
T
O
B
O
T
T
O
M
O
F
B
L
E
N
D
E
D
S
T
O
R
A
G
E
T
A
N
K
S
H
E
L
F
HOT WATER TANK (SEE
SPECIFICATIONS & HOT WATER
TANK DETAIL FOR FURTHER
INSTALLATION REQUIREMENTS)
1" (25MM)
BRASS CHECK
VALVE
EXPANSION TANK
STRAP UNITS PER LOCAL
REQUIREMENTS
HOT WATER TO DISHWASHER
(IF OTHER THAN HOBART
ADVANSYS UNIT), BAR SINKS,
MOP SINK AND COMPARTMENT
SINK.
1" (25MM) HOT WATER OUTLET
TEMPERED HOT WATER TO
HAND SINKS
TEMPERATURE MIXING
VALVES
UNION (TYP.)CONCEALED
COPPER PIPING (TYP.)
IF CONFIGURATION II
OR III, SOFTENED
COLD WATER TO
DISHWASHER
(IF HOBART
ADVANSYS UNIT).
SEE NOTE 2 BELOW.
OPEN CEILING ABOVE
WATER HEATER PER
LOCAL CODE
PAN AND DRAIN LINE FOR
MAINTENANCE
BOOSTER PUMP.
SEE BOOSTER PUMP
DETAIL FOR MORE
INFORMATION.
FL
O
W
DI
R
E
C
T
I
O
N
NOTES:
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND ADVANSYS
DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4.. ENSURE ALL PENETRATIONS THROUGH SURROUNDING WALLS AND CEILING ARE COMPLETELY SEALED..
FLOW
DIRECTION
3/4" (20MM)
CHROME ESCUTCHEONS (TYP.)
3/4" (20MM)
BRASS THREADED BALL SHUT-OFF VALVE
(TYP.) MAX 72" (1830MM) A.F.F.
UNION (TYP.)
3/4" (20MM)
FILTERED COLD WATER
TO ICE MACHINE
POINT OF USE
FILTER LOCATED AT
ICE MACHINE
MOP SINK
NOTES :
1. ALL COMPONENTS DRAWN IN BOLD ARE GC RESPONSIBILITY. GC TO COORDINATE INSTALLATION OF ALL OTHER COMPONENTS SHOWN WITH FILTER VENDOR.
2. ALL PIPING SHALL BE COPPER EXCEPT PEX TYPE PIPING WHICH IS ACCEPTABLE BETWEEN FILTER SYSTEM COMPONENTS AND FROM SOFTNER TO ADVANSYS DISHWASHER WHERE ALLOWED BY CODE.
3. COORDINATE WITH ELECTRICAL CONTRACTOR FOR RECEPTACLES.
4. PROVIDE WATER SOFTENER INDIRECT DRAIN TO SINK, INSTALLED PER CODE. (CONFIRM REQUIREMENTS WITH SOFTENER EQUIPMENT CUTSHEETS IN ITEM SPECIFICATIONS).
5. IN MUNICIPALITIES WITH BRINE RESTRICTIONS, REFER TO THE WATER SYSTEM CONFIGURATIONS APPENDIX UNDER ITEM SPECIFICATIONS FOR WATER SOFTENER EXCHANGE TANK SCHEMATIC.
6. COMPONENTS ARE TO BE POSITIONED TO MAXIMIZE ACCESS FOR REGULAR SERVICING. PRE-FILTER, BYPASS VALVES, AND SOFTENER TANKS MUST BE INSTALLED 72" (1828MM) AFF OR LOWER.
R.O. PERMEATE
TANK
7"(75MM)
(180MM)
9 1/4"(75MM)
(235MM)
GFCI 120V QUAD
RECEPTACLE FOR
FILTER SYSTEM 77"
(1955MM) A.F.F.
(SEE NOTE 3)FILTERED COLD WATER
TO FIXTURES (ESPRESSO
MACHINES, BREWERS,
HOT TAP, WATER TOWER
FAUCET)
75
"
(
7
9
0
5
M
M
)
OUT
R.O. CONTROL SYSTEM
(SEE NOTE 5)
3/4" (20MM)
SHUT-OFF
VALVE
3/4" (15MM)
FIP
3/4" (20MM) SHUT-OFF VALVE
3/4" (20MM) BYPASS
3/4" (20MM) SHUT-OFF
VALVE
CITY WATER IN
TO NON FILTERED
FIXTURES (TOILETS,
HAND SINKS, DIPPER
WELLS, BLENDER
PITCHER RINSERS,
IN-COUNTER RINSERS,
BAR SINKS, HOSE BIBBS)
3/4" (20MM) FIP
(FEMALE
INTERNATIONAL
PIPE THREAD
FITTING) (TYP. 1 OF
2 TO SOFTENER)
GFCI 120V
RECEPTACLE FOR
FILTER SYSTEM AT
54" (1372MM) A.F.F.
(SEE NOTE 3)
IN
BRINE TANK (FRONT)
WATER SOFTENER
HEAD AND TANKS
(BEHIND)
DRAIN LINE FROM
WATER HEATER
TANK PAN ABOVE
11"(75MM)
255MM)
3"(75MM)
WATER
HEATER TANK
SEE WATER
HEATER TANK
DETAIL FOR
MORE
INORMATION
FROM WATER
HEATER TANK
TEMPERING
VALVE
OUT
IN IN
TO HOT WATER TANK
AND ADVANSYS
DISHWASHER
PLUMBING. SEE
WATER HEATER TANK
DETAIL FOR MORE
INORMATION
BYPASS VALVE
BLENDED STORAGE
TANK ON WALL
MOUNTED SHELF
5'-
0
"
(
1
5
2
5
M
M
)
TO R.O. SYSTEM
BOOSTER
PUMP
BYPASS
VALVE
3/4" (20MM)
CITY
WATER
IN
BOOSTER
PUMP
SHUT-OFF
VALVE
TO
BOOSTER
PUMP
3/4" (20MM)
BOOSTED
WATER IN
5'
-
9
"
(
7
5
M
M
)
WATER FILTRATION
BOOSTER PUMP.
SEE BOOSTER
PUMP DETAIL
FOR MORE
INFORMATION
P-500
PLUMBING
DETAILS
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
1/2" = 1'-0"2CONFIGURATION III
3/4" = 1'-0"3WATER HEATER TANK - PLUMBING
1" = 1'-0"1CONFIGURATION III, R.O. AND SOFTENER WATER FILTRATION
5
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
ABOVE COUNTER
ICE BIN (TYP. 1 OF 2)
NON-FILTERED COLD
WATER SUPPLY FOR
METERED SPOON RINSER
(TYP. 1 OF 2)
NON-FILTERED COLD
WATER SUPPLY FOR
PITCHER RINSER
(TYP. 1 OF 2))
RINSER SINK
(TYP. 1 OF 2)
2'
-
6
1
/
2
"
7' - 9 3/4"
UNDER COUNTER
12' - 7 1/4"
UNDERCOUNTER
REFRIGERATOR
(TYP. 1 OF 2)
ICE BIN ABOVE WITH
INDIRECT AND
INSULATED DRAIN
LINE TO NEAREST
FLOOR SINK
UNDERCOUNTER CABINET
UNDERCOUNTER
REFRIGERATOR
(TYP. 1 OF 2)
INDIRECT DRAIN LINE
FROM ESPRESSO
MACHINE TO FLOOR
SINK
INDIRECT DRAIN LINE FROM
RINSER SINK TO FLOOR SINK
FLOOR SINK (TYP. 1 OF 2)
SEE PLUMBING PLAN FOR
FINAL LOCATIONS AND
TYPE
ICE BIN ABOVE
WITH INDIRECT AND
INSULATED DRAIN
LINE TO FLOOR
SINK BELOW
COUNTERTOP SUPPORT
LEG (TYP. 1 OF 3)
UNDERCOUNTER BOILER
FOR INSTANT HOT WATER
FONT (TYP 1 OF 2)
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER FONT
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR UNDERCOUNTER
INSTANT HOT WATER BOILER
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER DISPENSER
(TYP. 1 OF 2)
*
FILTERED COLD WATER
SUPPLY FOR ESPRESSO
MACHINES
**
UNDERCOUNTER
CABINET
PROVIDE WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND
FLEX HOSE CONNECTION*
**PROVIDE BACKFLOW PREVENTION DEVICE BEFORE PUMP AND WATER
HAMMER ARRESTOR PRIOR TO SHUT-OFF VALVE AND FLEX HOSE
INDIRECT DRAIN LINE
FROM RINSER SINK TO
FLOOR SINK
INDIRECT DRAIN LINE FROM ESPRESSO
MACHINE TO NEAREST FLOOR SINK
1' - 2"
SEE PLUMBING
PLAN FOR FINAL
FLOOR SINK
LOCATION AND
TYPE
ICE BIN
ABOVE
INDIRECT DRAIN LINE
FROM ESPRESSO
MACHINE TO FLOOR
SINK
UNDERCOUNTER
REFRIGERATOR
INDIRECT DRAIN
LINE FROM
RINSER SINK TO
FLOOR SINK
UNDERCOUNTER
CABINET
INDIRECT AND
INSULATED DRAIN LINE
FROM ICE BIN ABOVE
TO FLOOR SINK
SUPPORT
LEG (TYP.)
2'
-
6
1
/
2
"
UNDER COUNTER
UNDERCOUNTER
REFRIGERATOR
NON-FILTERED COLD
WATER SUPPLY FOR
METERED SPOON RINSER
NON-FILTERED COLD
WATER SUPPLY FOR
PITCHER RINSER
ICE BIN
RINSER SINK
UNDERCOUNTER
CABINET
ABOVE COUNTER
5' - 9"
UNDERCOUNTER
BOILER FOR INSTANT
HOT WATER FONT
FILTERED COLD
WATER SUPPLY
FOR ESPRESSO
MACHINE
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER DISPENSER
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER FONT
*
FILTERED COLD WATER
SUPPLY FOR INSTANT
HOT/COLD WATER BOILER
*
*
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO
SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
**PROVIDE BACKFLOW PREVENTION DEVICE
BEFORE PUMP AND WATER HAMMER ARRESTOR
PRIOR TO SHUT-OFF VALVE AND FLEX HOSE
CONT. INDIRECT AND
INSULATED DRAIN LINE
FROM ICE BIN AT SECOND
ESPRESSO BAR TO
FLOOR SINK HERE
CONT. INDIRECT DRAIN LINE
FROM ESPRESSO MACHINE
AT SECOND ESPRESSO BAR
TO FLOOR SINK HERE
HOT AND COLD WATER
FOR SINK FAUCET AT 20
1/2" (520MM) A.F.F. SHUT-
OFF VALVES AT WALL
AND 4" (100MM) EITHER
SIDE OF WASTE LINE.
FILTERED
COLD WATER
SUPPLY FOR
BREWER WITH
SHUT-OFF IN
CABINET AT
24" (610MM)
A.F.F.
7' - 6"
*
PROVIDE BACKFLOW PREVENTION DEVICE THEN
WATER HAMMER ARRESTOR PRIOR TO SHUT-OFF
VALVE AND FLEX HOSE CONNECTION
*
FLOOR SINK
10"
F
L
O
O
R
S
I
N
K
2'
-
5
1
/
2
"
SEE PLUMBING PLAN FOR FINAL
FLOOR SINK LOCATION AND TYPE
INDIRECT DRAIN LINE FROM
RINSE SINK TO FLOOR SINK
INDIRECT
DRAIN LINE
FROM
BREWER TO
FLOOR SINK
DIRECT DRAIN LINE FROM
SINK. ROUGH-IN SINK
WASTE STUB AT 15 1/2"
(394MM) A.F.F. AND
CENTERLINE OF SINK
TEMPERED HOT AND COLD
WATER FOR SINK FAUCET
AT 20 1/2" (520MM) A.F.F.
SHUT-OFF VALVES AT WALL
AND 4" (102MM) EITHER
SIDE OF WASTE LINE.
7 1/2"
1' - 3"
6' - 6"
FLOOR SINK
ELEVATION - PLUMBING DIAGRAM
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER INJECTION
WITH SHUT-OFF IN
CABINET AT 18" (457MM)
A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
COLD WATER SUPPLY
FOR COMBI OVEN
CLEANING WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
FILTERED WATER
SUPPLY FOR COMBI
OVEN WATER
INJECTION WITH SHUT-
OFF IN CABINET AT 18"
(457MM) A.F.F.
INDIRECT DRAIN LINE
FROM COMBI OVEN TO
FLOOR SINK
SEE PLUMBING PLAN
FOR FINAL FLOOR SINK
LOCATION AND TYPE
PLAN - PLUMBING DIAGRAM
P-501
PLUMBING
DETAILS
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
3/4" = 1'-0"4ESP 14-01 PLUMBING
3/4" = 1'-0"5DTE 06-03 PLUMBING
3/4" = 1'-0"1BRW 09-01 PLUMBING 3/4" = 1'-0"3ADD 02-01 PLUMBING
3/4" = 1'-0"2CBE 19-01 PLUMBING
5
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
SINK
SEE PLUMBING
PLAN FOR FINAL
FLOOR SINK
LOCATION AND
TYPE
.6" (152MM) MIN.
CLEAR TO BACK
WALL
INDIRECT DRAIN
LINE FROM ICE BIN
TO FLOOR SINK
INDIRECT DRAIN
LINE FROM ICE
DIVERTER TO
FLOOR SINK
ICE MACHINE
ICE TRANSPORT
TUBE BETWEEN ICE
MACHINE AND
DIVERTER VALVE.
MAX. LENGTH 10'
(3M)
ICE HEAD ADAPTER
ICE MANAGER
CONTROL PANEL
ICE TRANSPORT
TUBE LANE 2, TO
ICE BIN. MAX
LENGTH 75', MIN.
SLOPE 1/4":1'
ICE TRANSPORT
TUBE LANE 1, TO
ICE DISPENSER.
MAX LENGTH 75',
MIN. SLOPE 1/4":1'
3" PVC SLEEVE TO
SUPPORT ICE
TRANSPORT
TUBEFASTENED TO
WALL OR CEILING
W/ STRAPING @ 48"
O.C. MIN.
ICE DIVERTER
VALVE
ELEVATION - PLUMBING DIAGRAM
PLAN - PLUMBING DIAGRAM
CONT. FRP TO
CEILING ON BACK
WALL OVER IN
WALL BLOCKING
ICE BIN
ICE MACHINE
ICE HEAD ADAPTER
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
NOTE:
INDIRECT DRAIN MIN. RADIUS = 8"
ICE TRANSPORT TUB MIN. RADIUS = 6"
ECO-GRIP COVER
BASE
ACCESSIBLE
CLEARANCE AT
CONTROL PANEL
ICE MANAGER
CONTROL PANEL
ICE DIVERTER
VALVE
CONT. FRP ON
BACK WALL OVER
IN WALL BLOCKING
BACK WALL
MIN.
r 6"
BIN TOP SENSOR
DISTRIBUTION UNIT
ICE BIN
INDIRECT DRAIN
LINE FROM ICE
MACHINE TO FLOOR
SINK
4' - 0"
2'
-
6
"
Plan View
KEEP CLEAR FOR WALL MOUNTED CHEMICAL DISPENSING SYSTEM, TO BE INSTALLED
BY SYSTEM VENDOR. PROVIDE BACKING BEHIND WALL FINISH FOR EQUIPMENT
MOUNTING. REFER TO POSTED INSTALLATION GUIDELINES FOR MORE INFORMATION.
Elevation View
SOFTENED HOT AND NON-FILTERED COLD WATER FOR SINK FAUCET
INDIRECT DRAIN LINE FROM DISHWASHER TO NEAREST FLOOR SINK.
BACK WALL
WATER FOR DISHWASHER WITH SHUT-OFF UNDER SINK AT 18" (460MM) AFF. LINE
LENGTH MUST ALLOW EASE OF MOVEMENT. VERIFY WATER REQUIREMENTS FOR
TYPE OF DISHWASHER (HOT/COLD/SOFTENED). SEE WATER SUPPLY DRAWINGS
FOR WATER LINE. IF ADVANSYS DISHWASHER, INCLUDE PRESSURE REDUCING
VALVE. PRESSURE GAUGE (SET TO 20 PSIG +/- 5 PSI), LINE STRAINER AND SHOCK
ARRESTOR.
DRAIN LINE FROM SINK TO FLOOR SINK BELOW
SEE PLUMBING PLAN FOR FINAL FLOOR SINK LOCATION. FLOOR DRAIN OPTIONAL.
WIRE RACK
COMPARTMENT SINK DISHWASHER
NOTE:
FOR COORDINATION ONLY. SEE FURNITURE, FIXTURES, AND EQUIPMENT PLAN
FOR EQUIPMENT LOCATIONS. PROVIDE BACKING BEHIND WALL FINISH AS
REQUIRED FOR WALL MOUNTED EQUIPMENT. REFER TO ITEM SPECIFICATIONS
FOR MORE INFORMATION.
PRE-WASH STATION
(1
3
7
0
M
M
)
4'
-
6
"
DRAIN LINE FROM DISHWARE DRYING RACKS TO SINK BOWL
DISHWARE DRYING RACKS WITH DRAIN LINE TO SINK BOWL
ALIGN
(1
1
9
5
M
M
)
3'
-
1
1
"
(9
6
5
M
M
)
3'
-
2
"
12' - 3"
3/4" PLYWOOD BACKER BOARD BEHIND WALL FINISH. FASTEN TO STRUCTURE
BEYOND.
B
MOP SINK AND
WATER FILTRATION
EQUIPMENT. SEE
PLAN FOR ACTUAL
CONFIGURATION.
WATER HEATER TANK PER PLAN
HOT WATER TANK CHASE TO
ROOF STRUCTURE ABOVE. PAINT
GWB FINISH TO MATCH BOH FRP.
ROOF STRUCTURE PER PLAN
SECTION B
CLEAR
2' - 0"
7'
-
2
"
(
M
I
N
.
T
O
B
O
T
O
M
O
F
S
H
E
L
F
)
BOTTOM OF WORKROOM
CEILING IN FOREGROND
OPEN TO WORKROOM
A
SECTION A
OPTIONAL VCT CEILING.
HOLD TIGHT TO STRUCTURE
ABOVE
HOT WATER PIPING AND FLUE.
ENSURE ALL PENETRATIONS
THROUGH SURROUNDING WALLS
AND CEILING ARE COMPLETELY
SEALED.
CE
I
L
I
N
G
H
E
I
G
H
T
P
E
R
P
L
A
N
2"
BOOSTER PUMP
FILTERED COLD WATER
SUPPLY FOR WATER
TOWER FAUCET *
FILTERED
COLD WATER
SUPPLY FOR
INSTANT
HOT/COLD
WATER FONT
NON-FILTERED
HOT AND COLD
WATER SUPPLY
FOR SINK
FAUCET
ABOVE COUNTERTOP
AT FLOOR LEVEL
INDIRECT LINE
FROM PREP
SINK ABOVE TO
FLOOR SINK
SHELVING
ABOVE
FILTERED COLD
WATER SUPPLY FOR
UNDERCOUNTER
INSTANT HOT
WATER BOILER
(LOCATION MAY
VARY)
**
PROVIDE WATER HAMMER ARRESTOR PRIOR TO
SHUT-OFF VALVE AND FLEX HOSE CONNECTION*
P-502
PLUMBING
DETAILS
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
3/4" = 1'-0"1PLUMBING - NUGGET ICE - PEDESTAL STACK
3/4" = 1'-0"2SANITIZING (GENERIC) - PLUMBING
1/2" = 1'-0"3WATER HEATER TANK CHASE 3/4" = 1'-0"4WATER FILLING STATION - PLUMBING
5
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
P-503
PLUMBING
DETAILS
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
PROVIDE ONE PIECE SPUN ALUMINUM BASE WITH, GRADUATED
STEPPED PVC BOOT, AND ADJUSTABLE STAINLESS STEEL
CLAMPS. SET BASE IN BED OF MASTIC
FLOOR SLAB ON GRADE
REFER TO ARCHITECT'S
DRAWING FOR APPLICATION
INSTALLATION WITH
OF VENT PIPE BOOT
ROOFING MATERIAL
ROOF INSULATION
ROOF DECK
OF ROOF DECK
PROVIDE SLEEVE IF ANCHOR PIPE TO ROOF
MINIMUM 12" BELOW ROOF
REQUIRED BY TYPE
PROVIDE PIPE INCREASER
WHERE REQUIRED TO MAKE
MINIMUM 3" VENT THRU ROOF
DECK OR JOISTS WITH
WELDED OR SCREWED
U-BOLT AROUND PIPE
AND ANGLE IRON
TO DECK OR JOIST
HUBLESS PIPE
CONNECTORS ON
CAST IRON PIPE
REFER TO PLANS FOR VTR PIPE SIZES AND LOCATIONS. LOCATE VTR MINIMUM
TEN FEET HORIZONTAL OR THREE FEET VERTICAL ABOVE ANY BUILDING
OPENING OR FRESH AIR INTAKE, AND ONE FOOT FROM ANY VERTICAL SURFACE.
PROVIDE 1" FIBERGLASS INSULATION WITH ALL- SERVICE JACKET ON VENT PIPE
INSIDE BUILDING WITHIN SIX FEET OF VENT THRU ROOF LOCATION. VERIFY
FLASHING AND COUNTERFLASHING WITH ROOFING CONTRACTOR.
NOTES:
1.
2.
3.
4.
5.
6.
7.
12 VENT THRU ROOF
12" = 1'-0"11
NO-HUB
SEE SCHEDULE
SANITARY OR STORM
SEWER LINE
LONG SWEEP ELBOW AT
END OR TURN OF RUN
DIRECTION
OF FLOW
COMBINATION WYE AND
EIGHTH BEND IN RUN.
ENTER TOP OF PIPE
MINIMUM 12"
ABOVE ROOF
DEPTH OF SEWER
AS REQUIRED FOR
SAME SIZE AS SEWER UP
TO 4" MAXIMUM
MEMBRANE CLAMP
PROVIDE ROUND SECURED NICKEL BRONZE ADJUSTABLE TOP WITH "CO" CAST IN COVER.
PROVIDE CLEANOUT TOP WITH VARIATIONS SUITABLE FOR FLOOR COVERING (CARPET MARKER,
RECESSED FOR TILE, SCORIATED FOR UNFINISHED FLOORS).
PROVIDE BRONZE PLUG IN CAST IRON BODY.
LOCATE AT BUILDING EXIT, AT ENDS OF RUNS, AT TURNS OF PIPE GREATER THAN 45 DEGREES, AT 50'
INTERVALS ON STRAIGHT RUNS, AND WHERE SHOWN ON PLANS.
PROVIDE BACKFILL PER ARCHITECTURAL SPECIFICATIONS.
LOCATE CLEANOUTS WHERE THERE IS 18" CLEAR AROUND.
CONSULT LOCAL CODES FOR OTHER FCO REQUIREMENTS.
FLOOR CLEANOUT
12" = 1'-0"
1/2" TEMPERED HW SUPPLY
THERMOSTATIC MIXING VALVE
SET TEMPERATURE TO 110°F
P-TRAP
1/2" CW SUPPLY
PROVIDE METAL 360° INSULATION
SHIELD AND HIGH DENSITY INSULATION
OR PRE-ENGINEERED THERMAL HANGER
SHIELD INSERT OF CALCIUM SILICATE
INSULATION. FOR PIPES 4" AND SMALLER
PRE-ENGINEERED THERMAL HANGER SHIELD
INSERT OF FLEXIBLE UNICEULAR
INSULATION MAY BE PROVIDED
CUT INSULATION TO FIT AROUND
TRAPEZE HANGER. SEAL BOTH ENDS
OF EXPOSED INSULATION WITH
JOINT SEALANT
SIZE AND QUANTITY OF
HANGER RODS PER
MANUFACTURER'S
RECOMMENDATIONS
PROVIDE TWO-PIECE
PIPE CLAMP (TYP)
SUPPORT NUT
(TYP)
UNINSULATED STEEL
OR PLASTIC PIPE
UNINSULATED COPPER
PIPE
PROVIDE PLASTIC
GALVANIC ISOLATOR
FOR COPPER PIPE (TYP)
COLD INSULATED PIPE
TMV
-
1/2" HW
NOTES:
1.
NOTES:
1.
2.
SEE MATERIAL MATRIX FOR PIPE MATERIAL AND JOINING METHOD.
TMV TO HAVE A MINIMUM FLOW LESS THAN OR EQUAL TO ONE FAUCET'S MINIMUM FLOW
LAVATORY TAILPIPE AND HOT WATER LINES SHALL BE INSULATED OR COVERED PER CBC 11B-606.5.
2.
3.
4.
5.
6.
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. REFER TO
SPECIFICATIONS FOR MORE INFORMATION.
PIPE AND CONDUIT OF ALL TRADES MAY BE COMBINED ON THE SAME SUPPORT CHANNEL.
COORDINATE SUPPORT CHANNEL LENGTH WITH PIPING AND CONDUIT TO BE SUPPORTED.
SUPPORT CHANNEL SPACING SHALL BE DETERMINED BY SMALLEST PIPE TO BE SUPPORTED.
CHANNEL SUPPORT MAY BE USED AS A WALL BRACKET, ATTACH TO WALL WITH ANCHOR BOLTS PER
SPECIFICATIONS.
FOR HORIZONTAL INSULATED PIPING, ATTACH CLAMPS AS INDICATED ABOVE, FOR VERTICAL INSULATED
PIPING, ATTACH CLAMPS TO THE PIPE AND SEAL INSULATION AT BOTH CLAMP ENDS.
10 PUBLIC LAVATORY & HAND SINK W/ TMV
1" = 1'-0"8 MULTIPLE PIPE TRAPEZE HANGER
12" = 1'-0"
ANCHOR - PER NFPA
13 PIPE HANGAR
12" = 1'-0"
ON INSULATED PIPE. PROVIDE
PIPE SUPPORT SHIELD.
HANGER - GRINNEL FIG. 69
3/8" ALL-THREAD ROD FOR <=4" PIPE.
FOR LARGER PIPE SIZES SEE NFPA 13.
NOTE:
BUILDING STRUCTURE MAY VARY
MATCH INSTALLATION TO BUILDING
STRUCTURE REFER TO STRUCTURAL
DRAWINGS FOR ATTACHMENT.
1/2" CW PROVIDE 1-5/8"x1-5/8" 14
GA. CHANNEL SUPPORT
PIPE INSULATION (TYP)
HOT INSULATED PIPE
9 ECO-GRIP CLAMPING FLOOR SINK DETAIL
12" = 1'-0"
3" TAIL PIECE
NO-HUB
CONNECTION
GRAVEL
BACKFILL
CONC INFILL AND
TRENCH FOR
BELOW GRADE
UTILITIES
STAINLESS STEEL FLOOR
SINK W/CLAMPING FEATURE
FLOOR SINK HALF GRATE
FLUSH WITH FLOOR FINISH
3.
5
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
1
-
0
1
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
1/16" = 1'-0"1PLUMBING SITE PLAN PS-100
PLUMBING
SITE PLAN
3 PETERS CANYON RD. STE 110
IRVINE, CA 92606
D
G
ESI
N
|
ARCHITECTURE
H E S T I A A T E L I E R
SHEET NUMBER:
SHEET TITLE:
SCALE: AS SHOWN
STORE #:
PROJECT #:
PR
O
J
E
C
T
N
A
M
E
:
PR
O
J
E
C
T
A
D
D
R
E
S
S
:
C 2020 STARBUCKS COFFEE COMPANY
R
ISSUE DATE:
2401 UTAH AVENUE SOUTH
SEATTLE, WASHINGTON 98134
(206) 318-1575
THESE DRAWINGS AND THE PROJECT MANUAL
ARE CONFIDENTIAL AND SHALL REMAIN THE
SOLE PROPERTY OF STARBUCKS
CORPORATION, WHICH IS THE OWNER OF THE
COPYRIGHT IN THIS WORK. THEY SHALL NOT
BE REPRODUCED (IN WHOLE OR IN PART),
SHARED WITH THIRD PARTIES OR USED IN ANY
MANNER ON OTHER PROJECTS OR
EXTENSIONS TO THIS PROJECT WITHOUT THE
PRIOR WRITTEN CONSENT OF STARBUCKS
CORPORATION. THESE DRAWINGS AND
SPECIFICATIONS ARE INTENDED TO EXPRESS
DESIGN INTENT FOR A PROTOTYPICAL
STARBUCKS STORE (WHICH IS SUBJECT TO
CHANGE AT ANYTIME) AND DO NOT REFLECT
ACTUAL SITE CONDITIONS. NEITHER PARTY
SHALL HAVE ANY OBLIGATION NOR LIABILITY TO
THE OTHER (EXCEPT STATED ABOVE) UNTIL A
WRITTEN AGREEMENT IS FULLY EXECUTED BY
BOTH PARTIES.
STARBUCKS R
DESIGN MANAGER:
PRODUCTION DESIGNER:
CHECKED BY:
STARBUCKS TEMPLATE VERSION: i2021.04.23
09-14-2023
Revision Schedule
Rev Date By Description
October 23
28206-089
BR
I
S
T
O
L
&
W
A
R
N
E
R
23
0
3
A
S
.
B
R
I
S
T
O
L
S
T
.
S
A
N
T
A
AN
A
,
C
A
9
2
7
0
4
10005
<DESIGN MANAGER>
<DESIGNER>
<CHECKED BY>
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
A 12/21/23 PLAN CHECK COMMENT - 1
N
PLUMBING PLAN KEYNOTES
1 CONTRACTOR SHALL FIELD VERIFY ALL PIPE CONDITIONS PRIOR TO CONSTRUCTION , INCLUDING
EXACT LOCATION, AVAILABLE INVERT, DIRECTION OF FLOW, AND CAPACITY FOR THE ADDED
FIXTURE LOAD FROM THIS T.I..
SEE P-200 PLUMBING WASTE PLAN FOR CONTINUATION.
SEE P-100 PLUMBING WATER PLAN FOR CONTINUATION.
INSTALL NEW GREASE INTERCEPTOR.
GENERAL NOTES
A.FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY
SHOWN.
B.PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO
REVEAL FULL SCOPE OF WORK.
C.ALL PLUMBING LINES TO BE ROUTED SUCH THAT THEY ARE NOT VISIBLE TO CUSTOMERS
EXCEPT WHERE FIRST APPROVED BY STARBUCKS AT EXPOSED CEILING AREAS.
D.REFER TO MANUFACTURER SPECIFICATIONS FOR LOCATION OF CONNECTIONS UNLESS
OTHERWISE NOTED.
E.DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED.
F.REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK.
G.COLD WATER SUPPLY LINES INSIDE CASEWORK AND BAR AREA TO BE COVERED WITH 1/2"
(10MM) THICK SELF SEALING, SECTIONAL CLOSED-CELL FOAM INSULATION. REFER TO
SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS.
H.INSULATE ALL PIPING INCLUDING PIPES AT BAR AND IN CASEWORK PER THE REQUIREMENTS
LISTED IN THE PROJECT MANUAL.
I.FILTRATION SUPPLIER TO COORDINATE SOW AND SCHEDULE PRIOR TO INSTALLATION OF
WATER FILTRATION SYSTEM.
J.CONTRACTOR TO VERIFY (E) SUPPLY LINES WILL BE PROVIDE ADEQUATE PRESSURE & FLOW TO
RENOVATED SYSTEMS.
2
3
4
5
S 23071
S 23115
S 23117
S 23113
S 22544
S 23077
ADJACENT TENANT
Y 10020
PL
PL
PLPL
PL
PL
PL
PL PL
PL
2
4" SS
GI-1
X0022
21669
4
2% SLOPE
CW2''
1 3
2 1
4" GW
4" SS
4" SS
2% SLOPE
3"V B.G.
A
1S
T
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
/
2
1
/
2
0
2
3
2N
D
P
E
R
M
I
T
S
U
B
M
I
T
T
A
L
1
2
-
2
4
-
2
0
2
3
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
· Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
· Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
· If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
· In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
· Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
2. Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11. *Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( ) Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024
City of Santa Ana
Starbucks Bristol & Warner
2303A S. Bristol Street
Santa Ana, CA 92704
02/23/24
02/23/24
Navid Nassr
2303 S Bristol St #A - 101117496,
20181548, 30146629
2/27/2024