Loading...
HomeMy WebLinkAbout2115 N Greenbrier St - PlanNOTES VICINITY MAP AERIAL MAP CSLB # 1054136 PHONE 800.737.9892 NEXT DOOR HOME CONST. 9800D TOPANGA CANYON BLVD CHATSWORTH,CA 91311 CONTRACTOR: RESIDENCE: ERIC CHRISTENSEN 2115 N GREENBRIER S, SANTA ANA, CA 92706 APN #: 00111204 SHEET:1 REV:3/17/2023 COVER SHEET · ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: · 2022 CBC / 2021 IBC · 2022 CRC / 2021 IRC · 2022 CEC / 2020 NEC · 2022 CMC / 2021 UMC · 2022 CPC / 2021 UPC · 2022 CFC / 2021 IFC 1. ALL WORK TO COMPLY WITH CEC ARTICLE 690 2. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM 3. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR 4. ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY 5. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25° C; WIRE SHALL BE WET RATED AT 90°C 6. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV TYPE WIRE. 7. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS (CEC 314.15) 8. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS (CEC 250.90, 250.96) 9. FOR UNGROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS 10. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT (CEC 250.64C) 11. ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE 12. ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS 13. FOR GROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION 14. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD" 15. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT OF LESS THAN 4 PSF 16. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 45 LBS 17. AC DISCONNECT IS A "KNIFE BLADE" TYPE DISCONNECT 18. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26 19. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT 20. SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED ONTO THE EXISTING DWELLING AS PER THE 2019 CRC. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME; OTHERWISE, THE ALARMS MUST BE HARD WIRED AND INTERCONNECTED. (CRC R314, R315) 21. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTIONS R314 AND 315 TO BE VERIFIED AND INSPECTED BY THE INSPECTOR IN THE FIELD. 22. WHEN APPLYING THE 120% RULE OF CEC 705.12(B) THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER PER 705.12(B) 23. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES - NO BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED OR OBSTRUCTED SHEET INDEX 1 COVER SHEET 2.1 SIGNAGE 2 SITE/ROOF PLAN 3 STRUCTURAL 4 ELECTRICAL 5 ELECTRICAL CALCS SCOPE OF WORK INSTALLATION OF GRID-TIED SOLAR PHOTOVOLTAIC SYSTEM 24 APTOS 440W 440 W APTOS DNA-120-MF10-440W SOLAR MODULES 24 ENPHASE ENERGY 290 W IQ7PLUS-72-2-US(240V) [SI1] MICROINVERTERS SYSTEM NAMEPLATE POWER KW DC SYSTEM PTC POWER 9.59 KW CEC-AC CONSTRUCTION TYPE V-B OCCUPANCY TYPE R-3 10.56 BLDG# 101114794 ISS. 04/21/2023 ELEC# 20179404 ISS. 05/31/2023 ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** 2115 N Greenbrier St05/31/23 J-BOX NEMA3R NEW 125A ENPHASE IQ COMBINER BOX PV LOAD CENTER X-IQ-AM1-240-3 (W-/ INTEGRATED MONITORING) NEMA 3R 15A-2P S-ENVOY MONITOR A +- DC AC 20A-2P +- DC AC 20A-2P BRANCH CIRCUIT B: (08) APTOS 440W (DNA-120-MF10-440W) SOLAR MODULES PAIRED WITH (08) ENPHASE IQ 7+, 290 WATT (IQ7PLUS-72-2-US(240V) [SI1]) MICROINVERTERS BRANCH CIRCUIT C: (08) APTOS 440W (DNA-120-MF10-440W) SOLAR MODULES PAIRED WITH (08) ENPHASE IQ 7+, 290 WATT (IQ7PLUS-72-2-US(240V) [SI1]) MICROINVERTERS M 120/240 VAC SINGLE PHASE SERVICE GROUND 40A-2P (N) LOCKABLE BLADE TYPE NON-FUSIBLE AC DISCONNECT NEMA 3R EXISTING 200A MAIN BREAKER (TOP FED) EXISTING 200A MAIN PANEL 40A PV BREAKER INSTALLED AT OPPOSITE END OF BUSBAR FROM MAIN BREAKER NO CENTER-FED MAIN BREAKER 200A CB +- DC AC BRANCH CIRCUIT A: (08) APTOS 440W (DNA-120-MF10-440W) SOLAR MODULES PAIRED WITH (08) ENPHASE IQ 7+, 290 WATT (IQ7PLUS-72-2-US(240V) [SI1]) MICROINVERTERS 20A-2P SQUARE D DU222RB 60A-2P 120/240VAC CSLB # 1054136 PHONE 800.737.9892 NEXT DOOR HOME CONST. 9800D TOPANGA CANYON BLVD CHATSWORTH,CA 91311 CONTRACTOR: RESIDENCE: ERIC CHRISTENSEN 2115 N GREENBRIER S, SANTA ANA, CA 92706 APN #: 00111204 SHEET:4 REV:3/17/2023 ELECTRICAL ELECTRICAL SYSTEM NOTES: 1. ENPHASE IQ 7 / 7PLUS MICROINVERTERS DO NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS OR EQUIPMENT GROUNDING CONDUCTORS. THE MICROINVERTERS ITSELF HAS CLASS II DOUBLE-INSULATED RATING, WHICH INCLUDES GROUND FAULT PROTECTION. 2. ENPHASE Q CABLE HAS NO NEUTRAL WIRE - (2 WIRE DOUBLE INSULATED CABLING) 3. MODULES ARE BONDED TO RAIL USING IRONRIDGE INTEGRATED GROUNDING. 4. RAILS ARE BONDED WITH UL 2703 RATED LAY-IN LUGS 5. SYSTEM IS UNGROUNDED 6. BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA IRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC 250.64(C) 7. SUB-BRANCHES ARE CENTER-FED AT JBOX TO MAKE ONE TOTAL BRANCH CIRCUIT. 8. ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRAL TO BE LANDED AT THE NEUTRAL BUSS AT MAIN PANEL PER ENPHASE INSTALLATION INSTRUCTIONS. 9. ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READY PER NEC 690.12 CONDUCTOR / CONDUIT SCHEDULE Δ TAG CONDUCTOR CONDUCTOR SIZE NUMBER OF CONDUCTORS CONDUIT/CABLE TYPE CONDUIT SIZE A ENPHASE Q CABLE 12 AWG 2 FREE AIR N/A EGC/GEC: BARE COPPER 6 AWG 1 B LINE: THHN/THWN-2 10 AWG 6 EMT 3/4" EGC/GEC: THHN/THWN-2 8 AWG 1 C LINE: THHN/THWN-2 8 AWG 2 EMT 3/4"NEUTRAL: THHN/THWN-2 8 AWG 1 EGC/GEC: THHN/THWN-2 8 AWG 1 IRONRIDGE INTEGRATED GROUNDING & LAY-IN LUGS ARE UL2703 LISTEDGROUNDING DETAIL scale: NTS RAILS MODULES IRONRIDGE RAIL PV MODULE FRAME IRONRIDGE GROUNDING PIERCES THROUGH ANODIZED COATINGS OF MODULE FRAMES AND RAILS IRONRIDGE UNIVERSAL FASTENING OBJECT LAY-IN LUG TERMINAL AL/CU DUAL RATED (TIN PLATED CU) SS SET SCREW INCLUDED IRONRIDGE RAIL #10-24 SS LOCK NUT 6 AWG BARE CU WIRE TE#10-24 X 3/4" SS HCS BOLT #10 SS EXTERNAL TOOTH LOCK (STAR) WASHER ENPHASE Q CABLE TO BE ATTACHED TO RAIL MIN. 3-1/2" ABOVE ROOF SURFACE 2115 N Greenbrier St05/31/23 CSLB # 1054136 PHONE 800.737.9892 NEXT DOOR HOME CONST. 9800D TOPANGA CANYON BLVD CHATSWORTH,CA 91311 CONTRACTOR: RESIDENCE: ERIC CHRISTENSEN 2115 N GREENBRIER S, SANTA ANA, CA 92706 APN #: 00111204 SHEET:5 REV:3/17/2023 ELECT. CALCS ELECTRICAL CALCULATIONS AC WIRE SIZING CALCULATIONS AT ARRAY BRANCH CIRCUIT 1 (Max Micro Inverter Output) x (Continuous Load)[210.19(A)(1)] x (# Micros In Branch Circuit)=1.21 A x 1.25 x 08 12.10 A BRANCH CIRCUIT 2 (Max Micro Inverter Output) x (Continuous Load)[210.19(A)(1)] x (# Micros In Branch Circuit)=1.21 A x 1.25 x 08 12.10 A BRANCH CIRCUIT 3 (Max Micro Inverter Output) x (Continuous Load)[210.19(A)(1)] x (# Micros In Branch Circuit)=1.21 A x 1.25 x 08 12.10 A TOTAL AMPACITY (High Temp)[Table 310.16] x (Conductor Ampacity)[Table 310.16] x (Conduit Fill)[Table 310.15(B)(2)(a)]0.96 x 30A x 1.0 28.8A 12.10 A < 28.8‬ A. Therefore 12 AWG/ Q CABLE is sufficient AFTER J-BOX BRANCH CIRCUIT (Max Micro Inverter Output) x (Continuous Load)[210.19(A)(1)] x (# Modules In Branch Circuit)=1.21 A x 1.25 x 08 12.10 A TOTAL AMPACITY (High Temp)[Table 310.16] x (Conductor Ampacity)[Table 310.16] x (Conduit Fill)[Table 310.15(B)(2)(a)]0.82 x 40 x 0.80 26.24 A 12.10 A < 26.24 A. Therefore 10 AWG is sufficient AFTER PV LOAD CENTER MAX AC OUTPUT CURRENT (Σ of Micros in Branch Circuits ) x (Max Micro Inverter Output Current) x (Continuous Load)[210.19(A)(1)]24 x 1.21 A x 1.25 36.30 A TOTAL AMPACITY (High Temp)[Table 310.16] x (Conductor Ampacity)[Table 310.16] x (Conduit Fill)[Table 310.15(B)(2)(a)]0.94 x 50A x 1.0 47 A 36.30 A < 47 ‬A. Therefore 8 AWG is sufficient OCPD CALCULATIONS MAX AC OUTPUT CURRENT (Σ of Micros in Branch Circuits ) x (Max Micro Inverter Output Current) x (Continuous Load)[210.19(A)(1)]24 X 1.21 A x 1.25 36.30 A 36.30 A ≤ 40 A Overcurrent Protection INVERTER CHARACTERISTICS - ENPHASE IQ7PLUS-72-2-US (240V) [SI1] MAX OUTPUT POWER 290 W MIN INPUT / MAX START VOLTAGE 22 / 60 V MAX CONTINUOUS OUTPUT CURRENT 1.21 A MAX INPUT VOLTAGE 60 V MAX INPUT SHORT CIRCUIT CURRENT 15 A CEC MAX EFFICIENCY 97 % MAIN PANEL - 120% CALCULATION RATING OF MAIN BREAKER 200 A RATING OF MAIN BUSS BAR 200 A PV OCPD BREAKER 40 A (200 A BUSS X 1.2) - 200 A MAIN = 40 A MAXIMUM BACKFEED 40A PV OCPD ≤ 40 A MAXIMUM BACKFEED, BUSS OK ASSUMPTIONS HIGH TEMPERATURE 31 °C LOW TEMPERATURE 2 °C TEMP ADDER FOR ROOF RUN 17 °C TEMP ADDER FOR ATTIC RUN 7 °C DC DISCONNECT VALUES RATED MAX POWER-POINT CURRENT (IMP) 13.17 A RATED MAX POWER-POINT VOLTAGE (VMP) 34.16 V MAX SYSTEM VOLTAGE (VOC)41.34 V MAX SHORT CIRCUIT CURRENT (ISC)13.80 A MODULE CHARACTERISTICS - APTOS 440W (DNA-120-MF10-440W) SOLAR MODULES MAX POWER (PMAX) @ STC 440 W OPEN CIRCUIT VOLTAGE (VOC)41.34 V SHORT CIRCUIT CURRENT (ISC)13.80 A MAX POWER VOLTAGE (VMP)34.16 V MAX POWER CURRENT (IMP)13.17 A SERIES FUSE RATING 25.0 A 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 2115 N Greenbrier St05/31/23 Expedited Permit Process for PV Systems — Micro-Inverter2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 2115 N Greenbrier St05/31/23 ROOF MODULE LAYOUT+ EQUIPMENT LOCATIONS ROOF PITCH (DEG) AZIMUTH (DEG) PVAREA (SQ. FT.) NO.S OF MODSSCALE: 1/16" = l'-0" R324.6.2 Setback at ridge For photovoltaic arrays occupying not more than 33percent of the plan view total roof area, not less than an 18-inch (457 mm) clear set backis required on both sides of a horizontal ridge. For photovoltaic arrays occupying more than 33 percent of the plan view total roof area, not less than a 36-inch (914 mm) clear set back is required on both sides of a horizontal ridge � Cl) 0::: w 0:::cozww 0::: (9 z FIRE PATHWAY (N)CONDUIT RUN (N)JUNCTION BOX (E)STRUCTURE f------½----��f ARRAY 1 20° MODU LE MODU LE DIMEN SION S MODU LE WEIGHT TOTAL ARRAY 270°557.28 24 APTOS 440W (DNA-120-MF10-440W) 74.92" X 44.64" X 1.38" 52.9 LBS 557.28 SQ. FT. �,------�� � ��- - �- - �� TOT AL ROOF AREA 3488.02 SQ. FT. ROOF TYPE C OMP SH INGLE N (J) DRIVEWAY (E) FENCE PROPERTY LINE □ □ (N)IQ COMBINER BOX (N) AC DISCONNECT (E)MAIN PANEL AND SERVIC E ENTRAN C E (E)TREE (TYP.) (E)C HIMNEY NO. OF STORIES ROOF C OVERAGE 15.97 % CONTRACTOR: NEXT DOOR HOME CONST. 9800D TOPANGA CANYON BLVD --==t�'-" SWORTH,CA91311 CONDUIT NOTES CONDUIT TO BE RUN ON CONDUIT BLOCKS MIN. 1" ABOVE ROOF SURFACE AND UNDER EAVES; AND CLOSE TO RIDGELINES, LABELED AT MAX. 10' INTERVALS. CONDUIT TO BE PAINTED TO MATCH EXTERIOR/EXISTING BACKGROUND COLOR OF ITS LOCATION ENSEN ENBRIER S, �11N-'.NA, CA 92706 SITE PLAN REV:3/1 7/2023 SHEET:2 2115 N Greenbrier St05/31/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone: One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT 2115 N Greenbrier St05/31/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone: Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (P MAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90 oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram 2115 N Greenbrier St05/31/23 Towhom itmayconcern, Please acceptthis letter from EricChristensen, owner of the propertylocatedat 2115N. Greenbrier St., Santa Ana CA 92706. I am lettingthe cityknow thatNext Door Home Construction is authorizedtosubmititfor our solar projectpermitanddothe work for mysolar installation. Eric Christensen Home Owner DocuSign Envelope ID: 106A7C87-2A00-41CF-8CAF-8E73E2F6D7D2 2115 N Greenbrier St05/31/23 CSLB # 1054136 PHONE 800.737.9892 NEXT DOOR HOME CONST. 9800D TOPANGA CANYON BLVD CHATSWORTH,CA 91311 CONTRACTOR: RESIDENCE: ERIC CHRISTENSEN 2115 N GREENBRIER S, SANTA ANA, CA 92706 APN #: 00111204 SHEET:2.1 REV:3/17/2023 WEATHER RESISTANT PLASTIC PLACARD PLACEMENT: MAIN PANEL (COVER) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: SIGNAGE 2115 N GREENBRIER S, SANTA ANA, CA 92706 SIGNAGE PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) ADHESIVE FASTENED SIGNS: · THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. · WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING]. · ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3] SIGNAGE REQUIREMENTS: · RED BACKGROUND · WHITE LETTERING · MINIMUM 3/8" LETTER HEIGHT · ALL CAPITAL LETTERS · ARIAL OR SIMILAR FONT, NON-BOLD · REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13 & CEC 690.13) LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13 & CEC 690.13) WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED CAUTION: SOLAR CIRCUIT WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! WARNING: PHOTOVOLTAIC POWER SOURCE WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING! WARNING - Electric Shock Hazard No user serviceable parts inside Contact authorized service provider for assistance ! AC SYSTEM DISCONNECT FOR UTILITY OPERATION LABEL LOCATION: UTILITY DISCONNECT LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 29.04 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: RAPID SHUTDOWN OR ON INVERTER IS RSD IS INTEGRATED CEC 690.56(C)(3) LABEL LOCATION: SERVICE DISCONNECTING MEANS (PER CODE: CEC 690.56(C)(1)(A) LABEL LOCATION: PER CEC 705.12(B)(2)(3)(B) [OR (C) IF PANELBOARD IS RATED NOT LESS THAN SUM OF AMPERE RATINGS OF ALL OVERCURRENT DEVICES SUPPLYING IT] LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC/AC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(B)(3-4)) DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.13(B)) [To be used when inverter is ungrounded] ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.53) SOLAR ARRAY RATED MAXIMUM POWER- . POINT CURRENT (Imp) . RATED MAXIMUM POWER- . POINT VOLTAGE (Vmp) . MAXIMUM SYSTEM . VOLTAGE (VOC) . MAXIMUM CIRCUIT . CURRENT (Isc) . A V V A 41.34 13.17 INVERTER 34.16 13.80 (E) MAIN PANEL (N) IQ COMBINER BOX (N) AC DISCONNECT 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) The IQ Combiner 4/4C with IQ Gateway and integrated LTE-M1 cell modem (included only with IQ Combiner 4C) consolidates interconnection equipment into a single enclosure. It streamlines IQ Microinverters and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. IQ Combiner 4/4C Data Sheet Enphase Networking Smart • ncludes IQ Gateway for communication and control • Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), included only with IQ Combiner 4C • ncludes solar shield to match Enphase IQ Battery aesthetics and deflect heat • upports Wi-Fi, Ethernet, or cellular connectivity • ptional AC receptacle available for PLC bridge • Provides production metering and consumption monitoring Simple • Mounts on single stud with centered brackets • Supports bottom, back and side conduit entry • Allows up to four 2-pole branch circuits for 240VAC plug-in breakers (not included) • 80A total PV or storage branch circuits Reliable • Durable NRTL-certified NEMA type 3R enclosure • Five-year limited warranty • Two years labor reimbursement program coverage included for both the IQ Combiner SKU's • UL listed • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with IEEE 1547:2018 (UL 1741-SB, 3rd Ed.) X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) To learn more about Enphase offerings, visit enphase.com IQ-C-4-4C-DS-0103-EN-US-12-29-2022 © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of Enphase Energy, Inc. Data subject to change. MODEL NUMBER IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes a silver solar shield to match the IQ Battery and IQ System Controller 2 and to deflect heat. IQ Combiner 4 X-IQ-AM1-240-4 X2-IQ-AM1-240-4 (IEEE 1547:2018) IQ Combiner 4C X-IQ-AM1-240-4C X2-IQ-AM1-240-4C (IEEE 1547:2018) IQ Combiner 4C with IQ Gateway printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 ± 0.5%) and consumption monitoring (± 2.5%). Includes Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05), a plug-and-play industrial-grade cell modem for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.) Includes a silver solar shield to match the IQ Battery and IQ System Controller and to deflect heat. ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ6/7 Microinverters with IQ8) Communications Kit COMMS-CELLMODEM-M1-06 CELLMODEM-M1-06-SP-05 CELLMODEM-M1-06-AT-05 - Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year Sprint data plan - 4G based LTE-M1 cellular modem with 5-year AT&T data plan Circuit Breakers BRK-10A-2-240V BRK-15A-2-240V BRK-20A-2P-240V BRK-15A-2P-240V-B BRK-20A-2P-240V-B Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215 Circuit breaker, 2 pole, 20A, Eaton BR220 Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support Circuit breaker, 2 pole, 20A, Eaton BR220B with hold down kit support XA-SOLARSHIELD-ES XA-PLUG-120-3 X-IQ-NA-HD-125A Consumption monitoring CT (CT-200-SPLIT/CT-200-CLAMP) Replacement solar shield for IQ Combiner 4/4C Accessory receptacle for Power Line Carrier in IQ Combiner 4/4C (required for EPLC-01) Hold-down kit for Eaton circuit breaker with screws A pair of 200A split core current transformers ELECTRICAL SPECIFICATIONS Rating Continuous duty System voltage 120/240VAC, 60 Hz Eaton BR series busbar rating 125A Max. continuous current rating 65A Max. continuous current rating (input from PV/storage) 64A Max. fuse/circuit rating (output)90A Branch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. total branch circuit breaker rating (input)80A of distributed generation/95A with IQ Gateway breaker included IQ Gateway breaker 10A or 15A rating GE/Siemens/Eaton included Production metering CT 200A solid core pre-installed and wired to IQ Gateway MECHANICAL DATA Dimensions (WxHxD)37.5 cm x 49.5 cm x 16.8 cm (14.75 in x 19.5 in x 6.63 in). Height is 53.5 cm (21.06 in) with mounting brackets. Weight 7.5 kg (16.5 lbs) Ambient temperature range -40ºC to +46ºC (-40ºF to 115ºF) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Wire sizes Altitude • 0A to 50A breaker inputs: 14 to 4 AWG copper conductors • 0A breaker branch input: 4 to 1/0 AWG copper conductors • ain lug combined output: 10 to 2/0 AWG copper conductors • eutral and ground: 14 to 1/0 copper conductors • lways follow local code requirements for conductor sizing. Up to 3,000 meters (9,842 feet) INTERNET CONNECTION OPTIONS Integrated Wi-Fi IEEE 802.11b/g/n Cellular CELLMODEM-M1-06-SP-05, CELLMODEM-M1-06-AT-05 (4G based LTE-M1 cellular modem). Note that an Mobile Connect cellular modem is required for all Enphase Energy System installations. Ethernet Optional, IEEE 802.3, Cat5E (or Cat6) UTP Ethernet cable (not included) COMPLIANCE Compliance, IQ Combiner CA Rule 21 (UL 1741-SA) IEEE 1547:2018 - UL 1741-SB, 3rd Ed. (X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C) CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003 Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Consumption metering: accuracy class 2.5 Compliance, IQ Gateway UL 60601-1/CANCSA 22.2 No. 61010-1 IQ Combiner 4/4C IQ-C-4-4C-DS-0103-EN-US-12-29-2022 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 2115 N Greenbrier St05/31/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.Will the PV system weigh maximum 4 pounds per square feet or less? 5.Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.Will the PV system be installed without using any ballast system or counter-weight system? 8.Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M -19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org NEXT DOOR HOME CONSTRUCTION 1054136 2115 N Greenbrier St., Santa Ana, CA 92706 SANDRA VENTOSA 818-670-1071 ADMIN@NEXTDOORSOLAR.COM 4/4/23 2115 N Greenbrier St05/31/23 Certificate Of Completion Envelope Id: 106A7C872A0041CF8CAF8E73E2F6D7D2 Status: Completed Subject: Complete with DocuSign: Letter of Authorization.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 4 Initials: 0 Ryan Lien AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 2617 Matera Ln San Diego, CA 92108 RyanL@SocalEnergySolutions.Us IP Address: 68.4.56.152 Record Tracking Status: Original 4/4/2023 11:33:31 AM Holder: Ryan Lien RyanL@SocalEnergySolutions.Us Location: DocuSign Signer Events Signature Timestamp Eric Christensen usc1980@outlook.com Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 174.195.137.45 Signed using mobile Sent: 4/4/2023 11:34:16 AM Viewed: 4/4/2023 2:24:29 PM Signed: 4/4/2023 2:24:51 PM Electronic Record and Signature Disclosure: Accepted: 4/4/2023 2:24:29 PM ID: a33b28d1-8b3f-4226-996a-545c6b47d73d In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 4/4/2023 11:34:16 AM Certified Delivered Security Checked 4/4/2023 2:24:29 PM Signing Complete Security Checked 4/4/2023 2:24:51 PM Completed Security Checked 4/4/2023 2:24:51 PM Payment Events Status Timestamps Electronic Record and Signature Disclosure 2115 N Greenbrier St05/31/23 CONSUMER DISCLOSURE From time to time, California Solar Systems (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign, Inc. (DocuSign) electronic signing system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to these terms and conditions, please confirm your agreement by clicking the ‘I agree’ button at the bottom of this document. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after signing session and, if you elect to create a DocuSign signer account, you may access them for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. To indicate to us that you are changing your mind, you must withdraw your consent using the DocuSign ‘Withdraw Consent’ form on the signing page of a DocuSign envelope instead of signing it. This will indicate to us that you have withdrawn your consent to receive required notices and disclosures electronically from us and you will no longer be able to use the DocuSign system to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures Electronic Record and Signature Disclosure created on: 7/20/2017 1:54:20 PM Parties agreed to: Eric Christensen 2115 N Greenbrier St05/31/23 electronically from us. How to contact California Solar Systems: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: ryanl@855casolar.com To advise California Solar Systems of your new e-mail address To let us know of a change in your e-mail address where we should send notices and disclosures electronically to you, you must send an email message to us at ryanl@855casolar.com and in the body of such request you must state: your previous e-mail address, your new e-mail address. We do not require any other information from you to change your email address.. In addition, you must notify DocuSign, Inc. to arrange for your new email address to be reflected in your DocuSign account by following the process for changing e-mail in the DocuSign system. To request paper copies from California Solar Systems To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an e-mail to ryanl@855casolar.com and in the body of such request you must state your e-mail address, full name, US Postal address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with California Solar Systems To inform us that you no longer want to receive future notices and disclosures in electronic format you may: i. decline to sign a document from within your DocuSign session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an e-mail to ryanl@855casolar.com and in the body of such request you must state your e-mail, full name, US Postal Address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software Operating Systems:Windows® 2000, Windows® XP, Windows Vista®; Mac OS® X Browsers:Final release versions of Internet Explorer® 6.0 or above (Windows only); Mozilla Firefox 2.0 or above (Windows and Mac); Safari™ 3.0 or above (Mac only) PDF Reader:Acrobat® or similar software may be required to view and print PDF files Screen Resolution:800 x 600 minimum Enabled Security Settings:Allow per session cookies ** These minimum requirements are subject to change. If these requirements change, you will be asked to re-accept the disclosure. Pre-release (e.g. beta) versions of operating systems and browsers are not supported. Acknowledging your access and consent to receive materials electronically 2115 N Greenbrier St05/31/23 To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please verify that you were able to read this electronic disclosure and that you also were able to print on paper or electronically save this page for your future reference and access or that you were able to e-mail this disclosure and consent to an address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electronic format on the terms and conditions described above, please let us know by clicking the ‘I agree’ button below. By checking the ‘I agree’ box, I confirm that: • I can access and read this Electronic CONSENT TO ELECTRONIC RECEIPT OF ELECTRONIC CONSUMER DISCLOSURES document; and • I can print on paper the disclosure or save or send the disclosure to a place where I can print it, for future reference and access; and • Until or unless I notify California Solar Systems as described above, I consent to receive from exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to me by California Solar Systems during the course of my relationship with you. 2115 N Greenbrier St05/31/23