HomeMy WebLinkAbout2329 N Fairmont Ave - PlanSHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:12/30/2023 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD T-1 WATERSON RESIDENCE NEW PHOTOVOLTAIC SYSTEM PROJECT - 4.800 kW COORDINATES: 33.767564, -117.857560 AERIAL VIEW PROJECT INFORMATION PROPERTY OWNER NAME: COLIN WATERSON PHONE:- CONTRACTOR NAME: ILUM SOLAR PHONE: 1-888-696-4586 DESIGN SPECIFICATIONS OCCUPANCY: R-3 CONSTRUCTION TYPE: SINGLE FAMILY RESIDENCE ZONING: RESIDENTIAL GROUND SNOW LOAD: 0 PSF WIND EXPOSURE: B WIND SPEED: 95 MPH APPLICABLE CODES & STANDARDS 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE (ENERGY) 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) 2020 NATIONAL ELECTRICAL CODE (NEC) 2022 CALIFORNIA FIRE CODE (CFC) TYPE OF INTERCONNECTION: BACKFEED BREAKER IN THE SSP SCOPE OF WORK SYSTEM SIZE: STC: 12 X 400W = 4.800 kW PTC: 12 X 376.7W = 4.520 kW (12) CANADIAN SOLAR CS6R- 400MS-HL [BLK] (400W) SOLAR MODULES (12) ENPHASE IQ8PLUS-72-2-US [240V] MICROINVERTERS (1) 125A ENPHASE IQ COMBINER 5/5C (X-IQ-AM1-240-5/5C) BOX (1) ENPHASE IQ BATTERY-5P-1P-NA BATTERY [240V] (2) 30A KNIFE AC DISCONNECT (SQUARE D DU221RB) (1) 125A SUB SERVICE PANEL MSP UPGRADE: NO MAIN BREAKER DERATE: NO RACKING & MOUNTING PV ATTACHMENT TYPE: UNIRAC FLASHKIT PRO FOR ASPHALT COMP SHINGLE ROOF RACKING TYPE: UNIRAC SM- ROOF MOUNT RACKING HARDWARE SHEET # T-1 T-2 PV-1 PV-2 PV-3 E-1,1.1 E-2 E-3 S-1 S-2 S-3 S-4 S-5 S-6 S-7 S-8 SHEET NAME COVER SHEET PLAN NOTES SITE PLAN LAYOUT ATTACHMENT DETAILS MOUNTING DETAILS ELECTRICAL DIAGRAM WARNING LABELS ELEVATION SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET Structural Only Signed: 01/02/2024 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg#: 101118370 Elec#: 20182176 Approvals: Elec: MSmith 2329 N Fairmont Ave - 201821764/3/2024 1.1.PROJECT NOTES: 1.2.THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE (NEC) ARTICLE 690, ALL MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.3.THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.4.GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH NEC 690.5(A) 1.5.ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC 690.4 & NEC 690.60: PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.6.MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO NEC 690.7. 1.7.ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [NEC 110.3]. 1.8.ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE NEC AND AHJ. 1.9.SCOPE OF WORK: 1.10.PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.11.WORK INCLUDES: 1.12.PV ROOF ATTACHMENTS - UNIRAC FLASHKIT PRO FOR ASPHALT COMP SHINGLE ROOF 1.13.PV RACKING SYSTEM INSTALLATION - UNIRAC SM ROOF MOUNT RACKING HARDWARE 1.14.PV MODULE AND INVERTER INSTALLATION - CANADIAN SOLAR CS6R- 400MS-HL [BLK] (400W) SOLAR MODULES / ENPHASE IQ8PLUS-72-2-US [240V] MICROINVERTERS 1.15.PV EQUIPMENT GROUNDING 1.16.PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.17.PV LOAD CENTERS (IF INCLUDED) 1.18.PV METERING/MONITORING (IF INCLUDED) 1.19.PV DISCONNECTS 1.20.PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.21.PV FINAL COMMISSIONING 1.22.(E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.23.SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE 1.24.SITE NOTES: 1.25.A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 1.26.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 1.27.THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 1.28.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 1.29.ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE.SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:12/30/2023 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD T-2 1.56.EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 1.57.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 1.58.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [2022 CEC 250.119] 1.59.THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC 690.47 AND CEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC 250, CEC 690.47 AND AHJ. 1.60.GROUND-FAULT DETECTION SHALL COMPLY WITH CEC 690.41 IN GENERAL AND CEC 690.41 (A)(1) SPECIFICALLY. 1.61.DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.62.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 1.63.DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 1.64.RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 1 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [CEC 690.12(B)]. LOCATION OF LABEL ACCORDING TO AHJ 1.65.ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC 690.8, 690.9, AND 240. 1.66.EQUIPMENT THAT IS LISTED, LABELED, OR BOTH SHALL BE INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR LABELING. CEC 110.3(B). 1.67.IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC 690.11 AND UL1699B. 1.68.ELECTRICAL INTERCONNECTION NOTES: 1.69.THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF THE BUSBAR RATING. 1.70.WHEN THE SUM OF THE PV SOURCES EQUALS >100% OF THE BUSBAR RATING, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD. 1.71.AT MULTIPLE PV OUTPUT COMBINER PANEL, THE TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED THE AMPACITY OF THE BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED. 1.72.SUPPLY-SIDE TAP INTERCONNECTION SHOULD BE WITH SERVICE ENTRANCE CONDUCTORS. 1.73.BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING. 1.30.EQUIPMENT LOCATIONS: 1.31.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY 2022 CEC 110.26. 1.32.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY 2022 CEC 690.31 (A),(C) AND CEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C) 1.33.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO 2022 CEC 690.34. 1.34.ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT . 1.35.ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO 2022 CEC APPLICABLE CODES. 1.36.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 1.37.STRUCTURAL NOTES: 1.38.RACKING SYSTEM 1.39.PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND 1.40.A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 1.41.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED SEALED PER LOCAL REQUIREMENTS. 1.42.ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 1.43.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 1.44.WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 1.45.WIRING & CONDUIT NOTES: 1.46.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 1.47.CONDUCTORS SIZED ACCORDING TO 2022 CEC 690.8, 2022 CEC 690.7. 1.48.VOLTAGE DROP LIMITED TO 2%. 1.49.DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 1.50.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CON2022 CECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [2022 CEC 110.15 1.51.GROUNDING NOTES: 1.52.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 1.53.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO 2022 CEC 690.43 AND MINIMUM 2022 CEC TABLE 250.122. 1.54.METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDING WITH 2022 CEC 250.134 AND 2022 250.136(A). 1.55.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. 2329 N Fairmont Ave - 201821764/3/2024 N SCALE: 3/32" = 1'-0" PV SYSTEM SITE PLAN PV SYSTEM SIZE: 4.8 kW DC/4.384 kW AC CONSTRUCTION NOTES LOCATION OF METER MAIN COMBO 23 2 9 F A I R M O N T A V E ROOF OBSTRUCTIONS SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:12/30/2023 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD PV-1 (12) CANADIAN SOLAR CS6R- 400MS-HL [BLK] (400W) SOLAR MODULES WITH AN ENPHASE IQ8PLUS-72-2-US [240V] MICRO-INVERTERS MOUNTED TO THE BACK OF EACH MODULE MOUNTED ON ASPHALT COMP SHINGLE ROOF (E) STRUCTURE ON PROPERTY 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC WIND SPEED OF 95 MPH (3 SECOND GUST), WIND EXPOSURE B. 3. THE ROOF MEMBERS ARE 2"X 4" RAFTERS AT 24" ON CENTER. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 11" OF NAILING PLATES. 4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (CRC R324.7.1, CBC 3111.2.1) 6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. 6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREES, WIRES, OR SIGNS. M LEGEND M METER MAIN COMBO CB COMBINER BOX BATT BATTERY ACD AC DISCONNECT DRIVEWAY NEW SOLAR PANELS LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 CAL-FIRE ROOF LADDER ACCESS POINT PROPERTY LINE PR O P E R T Y L I N E (E) SERVICE DROP Roof Section 1 Roof Azimuth: 180° Roof Tilt: 16° Roof Section 2 Roof Azimuth: 360° Roof Tilt: 16° NOTE : ENERGY STORAGE SYSTEMS (ESS) SHALL NOT BE LOCATED LESS THAN 3 FEET FROM DOORS AND WINDOWS DIRECTLY ENTERING THE DWELLING UNIT PER 2022 CALIFORNIA RESIDENTIAL CODE R328.4. PROPERTY LINE PROPERTY LINE CAL-FIRE ROOF LADDER ACCESS POINT SSP CBACD BATTACD PV INTERCONNECTION POINT. LOCATION OF SUB SERVICE PANEL, (2) AC DISCONNECT, COMBINER BOX & (1) ENPHASE IQ 5P BATTERY MOUNTED ON EXTERIOR WALL OF A SINGLE FAMILY RESIDENCE. LOCATION OF "RAPID SHUTDOWN" AC DISCONNECT NEC 690.12 PROPERTY LINE SSP SUB SERVICE PANEL Structural Only Signed: 01/02/2024 2329 N Fairmont Ave - 201821764/3/2024 SUB SERVICE PANEL ENPHASE e AC DISCONNECT 2' 2'-4"2'-2" 1'-3" 9" ENPHASE IQ COMBINER 5/5C 6" ENPHASEe ON EXTERIOR WALL OF A GARAGE 1'-11" 3' ENPHASE IQ BATTERY-5P-1P-NA [240] 2'-4" 1 AC DISCONNECT 9" 2 METER MAIN COMBO 2' ON EXTERIOR WALL OF HOUSE SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:12/30/2023 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD E-3EQUIPMENT ELEVATION VIEW POWER SOURCE DISCONNECT SCHEDULE DISCONNECT NUMBER TYPES OF DISCONNECT 1 OF 2 2 OF 2 KNIFE AC DISCONNECT FOR PV KNIFE AC DISCONNECT FOR ESS 2329 N Fairmont Ave - 201821764/3/2024 RO O F S L O P E 910 10 6 21 7 S-5 D5 20 11 121413151822 S-5 D4 3 1 54 252423 8 26 2 D4 DETAIL (TRANSVERSE) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE D3 RACKING DETAIL (TOP) NOT TO SCALE D2 RACKING DETAIL (LONGITUDINAL) NOT TO SCALE SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:12/30/2023 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD PV-3 ASPHALT COMP SHINGLE 1. ROOF MATERIAL: ASPHALT COMP SHINGLE 2. ROOF STRUCTURE: RAFTERS 3. ATTACHMENT TYPE: UNIRAC FLASHKIT PRO 4. MODULE MANUFACTURER: CANADIAN SOLAR 5. MODULE MODEL: CS6R- 400MS-HL [BLK] (400W) 6. MODULE LENGTH: 67.8'' 7. MODULE WIDTH: 44.6" 8. MODULE WEIGHT: 49.4 LBS. 9. SEE SHEET S-1 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 11. RAFTERS SPACING: 24" O.C. 12. RAFTERS SIZE: 2"X 4" NOMINAL 13. LAG BOLT DIAMETER: 5/16" IN. 14. LAG BOLT EMBEDMENT: 2.5 IN. 15. TOTAL # OF ATTACHMENTS: 20 16. TOTAL AREA: 251.99 SQ. FT. 17. TOTAL WEIGHT: 592.80 LBS. 18. WEIGHT PER ATTACHMENT: 29.64 LBS. 19. DISTRIBUTED LOAD: 2.35 PSF 20. MAX. HORIZONTAL STANDOFF: 72 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 39 IN. 22. STANDOFF STAGGERING: NO 23. RAIL MANUFACTURER AND MODEL (OR EQUIV.):UNIRAC SM 24. RAIL WEIGHT: 0.436 PLF. 25. MAX. RAFTERS SPAN: 12 FT. 26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. Structural Only Signed: 01/02/2024 2329 N Fairmont Ave - 201821764/3/2024 N 6'6' 6'6'6'6' N PROPOSED UNIRAC SM RACKING PROPOSED CANADIAN SOLAR CS6R- 400MS-HL [BLK] (400W) PV SOLAR MODULES EXISTING 2"X 4" ROOF RAFTERS @ 24"O.C. SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:12/30/2023 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD PV-2 Roof Section 1 Roof Azimuth: 180° Roof Tilt: 16° Roof Section 2 Roof Azimuth: 360 ° Roof Tilt: 16° SCALE: 3/16" = 1'-0" PV SYSTEM MOUNTING DETAILS UNIRAC FLASHKIT PRO FOR ASPHALT COMP SHINGLE ROOF @ 72" O.C. MAX EXISTING ASPHALT COMP SHINGLE ROOF Structural Only Signed: 01/02/2024 2329 N Fairmont Ave - 201821764/3/2024 (N) ENPHASE IQ BATTERY-5P-1P-NA [240] RO O F T O P GR O U N D L E V E L - HO U S E E X T E R I O R 20A 20A N 15A 2 (N) 125A ENPHASE X-IQ-AM1-240-5/5C COMBINER BOX WITH ENPHASE IQ ENVOY COMM. GATEWAY 4 PV WIRES NEEDS TO MAINTAIN A 1’ MINIMUM SEPARATION WHEN THERE IS PV OUTSIDE OF THE MICROGRID TO AVOID RISK OF CROSSTALKING BETWEEN ENVOYS. 1. ENVOY MUST BE NO FARTHER THAN 150' FROM THE LAST MICROINVERTER. 2. MAX DISTANCE BETWEEN ENSEMBLE DEVICES IS 50' LINE OF SIGHT WITH NO OBSTRUCTIONS. 12 PV CIRCUIT 1: 12 MODULES/PARALLEL 12 1 (N) JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE (N) 12 CANADIAN SOLAR CS6R- 400MS-HL [BLK] (400W) MODULES WITH AN ENPHASE IQ8PLUS-72-2-US [240V] MICRO-INVERTER ATTACHED TO THE BACK OF EVERY MODULE. NOTE: IN BETWEEN EACH ARRAY THE EMT IS USED AS THE GROUNDING / BONDING, GROUND CLAMPS ARE AT EACH END OF THE EMT CONDUIT WITH THE WIRE THEN FREE AIR'D TO THE GROUND CLAMP ON THE RACKING RAIL (N) VISIBLE LOCKABLE 2 POLE 60A 'KNIFE' AC DISCONNECT (SQUARE D DU221RB) 4 3 BACKFEED BREAKER M POINT OF DELIVERY AND INTERCONNECTION 200A EXISTING 240V/200A METER MAIN COMBO SINGLE PHASE (E) GROUNDING ELECTRODE OR (UFER) N CT CABLE (N) VISIBLE LOCKABLE 2 POLE 60A 'KNIFE' AC DISCONNECT SQUARE D DU222RB 3 100A 40A N EXISTING TRENCHING NEW 240V/125A SUB SERVICE PANEL SINGLE PHASE 100A SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:3/13/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD E-1 SUB SERVICE PANEL 240/120V 1Ø, 3W MAIN BUSS: 125A MAX BREAKER SIZE: (125A X 1.2) - 100A = 50A NOTE : CT CABLES SHOULD NOT RUN THROUGH BATTERIES HOT WIRE. ESS DETAILS MODEL NAME PEAK OUTPUT POWER TOTAL CAPACITY ENPHASE IQ BATTERY-5P-1P-NA 6.14 kVA 5.0 kWh NOTE : ENERGY STORAGE SYSTEMS (ESS) SHALL NOT BE LOCATED LESS THAN 3 FEET FROM DOORS AND WINDOWS DIRECTLY ENTERING THE DWELLING UNIT PER 2022 CALIFORNIA RESIDENTIAL CODE R328.4. NOTE : ALL EQUIPMENT LISTED IS SUBJECT TO AVAILABILITY AND MAY BE REPLACED WITH AN EQUIVALENT PRODUCT. 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:3/13/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD E-1.1 Inverter Ratings Inverter Make/Model ENPHASE IQ8PLUS-72-2-US [240V] Max DC Volt Rating 60V Max con output Power 290W Max Nominal Voltage 240V Max AC Current 1.21A Max OCPD Rating 20A DESIGN TEMPERATURES ASHRAE EXTREME LOW 2°C ASHRAE 2% HIGH 31°C PV Module Ratings @ STC Module Make/Model CANADIAN SOLAR CS6R- 400MS-HL [BLK] (400W) SOLAR MODULES Max Power-Point Current (Imp)12.99A Max Power-Point Voltage (Vmp)30.8V Open-Circuit Voltage (Voc)36.8V Short-Circuit Current (Isc)13.85A Max Series Fuse (OCPD)25A Nominal Maximum Power at STC (Pmax)400W Maximum System Voltage 1000V Voc Temperature Coefficient -0.26%/°C SYSTEM SUMMARY BRANCH #1 INVERTERS PER BRANCH 12 MAX AC CURRENT 14.52A MAX AC OUTPUT POWER 3480W ARRAY STC POWER 4800W MAX AC CURRENT 14.52A MAX AC POWER 3480W Conduit and Conductor Schedule Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size 1 Enphase Q cable - THWN-2 10 AWG 1 N/A - Free Air N/A - Free Air 1 Bare Copper Ground (EGC/GEC)6 AWG 1 N/A - Free Air N/A - Free Air 2 THWN-2 10 AWG 2 EMT 3/4" 2 THWN-2 - Ground 10 AWG 1 EMT 3/4" 3 THWN-2 8 AWG 3 EMT 3/4" 3 THWN-2 - Ground 10 AWG 1 EMT 3/4" 4 THWN-2 10 AWG 2 EMT 3/4" 4 THWN-2 - Ground 10 AWG 1 EMT 3/4" 2329 N Fairmont Ave - 201821764/3/2024 N POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: (N) SOLAR PANELS AND MICRO-INVERTERS ON ROOF SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:12/30/2023 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD E-2 23 2 9 F A I R M O N T A V E PV INTERCONNECTION POINT. LOCATION OF SUB SERVICE PANEL, COMBINER BOX, (2) AC DISCONNECT & (1) ENPHASE IQ BATTERY 5P . 1.NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. 2.ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE 3.ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. 4.DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. PERMANENT SIGNAGE NOTES: WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(2) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(3) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 705.15(C)(4)& 690.13(B) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022:690.56(C)(2), CFC 2022: 1204.5.3 MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 14.52 AMPS 240.0 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 CAUTION TRI POWER SOURCES SECOND SOURCE IS PV SYSTEM THIRD SOURCE IS AC BATTERY ! LABEL LOCATION : BATTERY F.D. – ELECTRICAL BLDG DISCONNECT # 2 of 2 # 2 F.D. – ELECTRICAL BLDG DISCONNECT # 1 of 2 # 1 LOCATION OF METER MAIN COMBO 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-1 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-10 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-11 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-2 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-3 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-4 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-5 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-6 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-7 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-8 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 SHEET CONTRACTOR ILUM SOLAR 2329 FAIRMONT AVE, SANTA ANA, CA 92706 APN:00310010 DATE:1/16/2024 WATERSON RESIDENCE License#:1092865, C-46 ADDRESS: 4135 NORTHGATE BLVD SUITE 9, SACRAMENTO, CA 95834, USA DESIGNER: OHD S-9 Signed 2/15/2024 Structural Only 2329 N Fairmont Ave - 201821764/3/2024 2329 N Fairmont Ave - 201821764/3/2024 2329 N Fairmont Ave - 201821764/3/2024 2329 N Fairmont Ave - 201821764/3/2024 01/02/2024 RE: Structural Certification for Installation of Residential Solar COLIN WATERSON:2329 FAIRMONT AVE, SANTA ANA, CA 92706 Attn: To Whom It May Concern Design Criteria Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 95 mph PV Dead Load DPV 3 psf Exposure B Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E.Signed 01/02/2024 EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition shingle roofing over roof plywood supported by 2X4 Rafters at 24 inches. The slope of the roof was approximated to be 16 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com 2329 N Fairmont Ave - 201821764/3/2024 Structural Letter for PV Installation Date:01/02/2024 Job Address:2329 FAIRMONT AVE SANTA ANA, CA 92706 Job Name:COLIN WATERSON Job Number:010224CW Scope of Work 2 Cover 3 Attachment Uplift checks 4 Roof Framing Check 5 Seismic Check and Scope of work Engineering Calculations Summary Code 2022 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 95 mph Exposure B References NDS for Wood Construction Sincerely, Signed 01/02/2024 Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 e PV r's This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Table of Content Sheet projects@evengineersnet.com http://www.evengineersnet.com 2329 N Fairmont Ave - 201821764/3/2024 Wind Load Cont. 95 mph ASCE 7-16 Figure 26.5-1B B 1.0 ASCE 7-16 Sec 26.8.2 0.57 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 0.99 ASCE 7-16 Table 26.9-1 11.13 psf 16.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1,2e)Zone(2r, 2n)Zone(3e)Zone(3r) Fig. 30-3-2 GCp=-1.1 -2 -2 -2.4 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-14.69 -26.71 -26.71 -32.05 GCp=0.5 Figure 30.3-2 P=qh(GCp)(γE)(γa)=3.67 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing=6 ft 5/16" Lag Screw Withdrawal Value=266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity=760 lbs Zone Trib Width Area (ft)Uplift (lbs)Down (lbs) Zone(1,2e)6 16.5 96.3 110.1 Zone(2r, 2n)6 16.5 161.8 110.1 Zone(3e)6 16.5 161.8 110.1 Zone(3r)6 16.5 190.8 110.1 Conservative Max=190.8 <760 CONNECTION IS OK 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2= Pitch = Lag Screw Penetration Risk Category = KZ = Kd = Ke = projects@evengineersnet.com http://www.evengineersnet.com 2329 N Fairmont Ave - 201821764/3/2024 Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg=0 psf Ct =1.1 Ce =0.9 Is =1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1)0 plf Max Length, L =8.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT =24 in Dr =10 psf 20 plf PvDL =3 psf 18 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL=41 plf Mdown=330 lb-ft Mallowable = Sx x Fb' (wind)=456 lb-ft >330 lb-ft OK Load Case: DL+S Ps+ Ppvcos(θ)+PDL=38 plf Mdown=304 lb-ft Mallowable = Sx x Fb' (wind)=456 lb-ft >304 lb-ft OK Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL=42.4 plf Max Moment, Mu=339 lb-ft Mallowable = Sx x Fb' (wind)=634 lb-ft >339 lb-ft OK Pv max Shear=110.1 lbs Shear, Vu=wL/2+Pv Point Load =262 lbs Max Shear, Vu=wL/2+Pv Point Load =262 lb Member Capacity DF-L No.2 2X4 CL CF Ci Cr KF φ λ Fb =900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi Fv =180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E =1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin =580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d =3.5 in Width, b =1.5 in Cross-Sectonal Area, A =5.25 in2 Moment of Inertia, Ixx =5.35938 in4 Section Modulus, Sxx =3.0625 in3 Allowable Moment, Mall = Fb'Sxx =396.2 lb-ft DCR=Mu/Mall =0.73 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A =630.0 lb DCR=Vu/Vall =0.42 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 2329 N Fairmont Ave - 201821764/3/2024 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 18% Dpv and Racking 3 psf Average Total Dead Load 10.6 psf Increase in Dead Load 2.2%OK Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - COLIN WATERSON. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this Structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com 2329 N Fairmont Ave - 201821764/3/2024