Loading...
HomeMy WebLinkAbout2229 S Laura Linda Ln - PlanOWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies A0 PROJECT INFO VICINITY MAP PV NOTES VICINITY MAP PROJECT SITE OWNER: VAN HUYNH ADDRESS:2229 S LAURA LINDA LN SANTA ANA, CA 92704 PHONE: (714) 588-7192 EMAIL: Van_huynh_2003@hotmail.com APN:40841409 (ORANGE COUNTY) UTILITY: SCE AERIAL VIEW 6.252 KW CEC-AC RATING SOLAR PV STRING INVERTER SYSTEM - ROOF MOUNT HUYNH RESIDENCE 2229 S LAURA LINDA LN SANTA ANA, CA 92704 ARRAY AREA: PROJECT SCOPE INSTALLATION OF ROOF MOUNT SOLAR PV SYSTEM NEW UPGRADE 225A MAIN SERVICE PANEL PV EQUIPMENT QTY MODEL NO AND MANUFACTURER MODULES: 17 Q.PEAK DUO BLK ML-G10+ 400 HANWHA Q CELL MODULES OPTIMIZERS: 17 P401 SOLAREDGE OPTIMIZERS INVERTER:1 SE6000H-US (240V) SETAPP SOLAREDGE HD INVERTER SYSTEM SIZE: 21.14 SQFT x 17 = 359.31 SQFT OCCUPANCY: R3-SFD CONSTRUCTION TYPE: VB # OF STORIES: 1 BLDG AREA (SQFT): 1212 SPRINKLERS: NONE ROOF AREA (SQFT): 2695 ENGINEERING CRITERIA FOR RACKING DESIGN WIND SPEED: 110 MPH WIND EXPOSURE CATEGORY: B GROUND SNOW LOAD: 0 PSF SOLAR PHOTOVOLTAIC SYSTEM NOTES 1. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE LISTING REQUIREMENTS AND THE MANUFACTURER'S INSTRUCTIONS, CEC 110.2, 110.3, 690.4(B) AND 690.12(D). 2. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND SWITCHES. 3. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 4. ALL PV CIRCUITS CONNECTED TO MORE THAN ONE SOURCE SHALL HAVE PROTECTION AGAINST OVERCURRENT PER CEC 690.9. 5. DISCONNECTING MEANS OF THE PV SYSTEM (INCLUDING RAPID SHUTDOWN INITIATION) SHALL BE LOCATED IN READILY ACCESSIBLE LOCATION NEAR THE EQUIPMENT, CEC 690.13, 690.15. 6. ENERGY STORAGE SYSTEMS TERMINALS LOCATED MORE THAN 5 FEET AWAY OR ON OPPOSITE SIDE OF WALL FROM CONNECTED EQUIPMENT MUST HAVE DISCONNECTING MEANS IN ACCORDANCE WITH CEC 706.7(E) AND LABELED PER 706.7(D). A SECOND DISCONNECTING MEANS LOCATED AT THE CONNECTED EQUIPMENT SHALL BE INSTALLED WHERE THE DISCONNECTING MEANS AT THE ESS END OF THE CIRCUIT IS NOT WITHIN SIGHT. 7. RAPID SHUTDOWN EQUIPMENT TO COMPLY WITH CEC 690.12. 8. THE UTILITY-INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED, CEC 705.40. 9. ALL CONDUCTORS IN EXPOSED OUTDOOR LOCATIONS SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT AND FOR THE APPLICATION. CEC310.10(D) AND 690.31(C) THROUGH (F). 10. INSULATION OF EXPOSED CONDUCTORS UNDER THE MODULES SHALL BE USE-2 OR PV-WIRE TYPE FOR PV SYSTEMS, CEC 690.31(C). 11. FINE-STRANDED CABLE CONNECTIONS MUST BE MADE IN LUGS AND TERMINALS LISTED AND MARKED FOR THE USE, CEC 110.14. 12. ALL PV CIRCUIT CONDUCTORS SHALL BE MARKED ON EACH END AND GROUPED FOR UNIQUE IDENTIFICATION, CEC 690.31(B). 13. ALL GROUNDED, (NEUTRAL), CONDUCTORS' INSULATION SHALL BE SOLID WHITE, GRAY, OR WITH 3-WHITE STRIPES, CEC 200.6, 200.7, & 400.22; AND ALL GROUNDING CONDUCTORS SHALL BE OF BARE WIRE WITHOUT COVERING, OR WITH INSULATION OF GREEN OR GREEN WITH YELLOW STRIPES, CEC 250.119 & 400.23. THE COLOR OF UNGROUNDED CONDUCTORS SHALL BE OTHER THAN FOR GROUNDED, (NEUTRAL), AND GROUNDING CONDUCTORS, CEC 310.110(C). 14. MAXIMUM CONDUCTOR LENGTH BETWEEN SUPPLY SIDE CONNECTION AND OVERCURRENT PROTECTION IS 10 FEET, CEC 705.31. 15. CONNECTIONS ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SOURCE(S) AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING, CEC 705.12(B). 16. DC WIRING INSIDE A BUILDING MUST BE IN METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, OR CABLE SHEATHINGS, CEC 690.31(G). 17. METALLIC TYPE RACEWAYS, CONDUITS, ENCLOSURES, AND CABLE SHEATHS CONTAINING CIRCUITS OVER 250-VOLTS TO GROUND MUST BE BONDED IN ACCORDANCE WITH CEC 250.97. 18. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES SHALL BE RAIN TIGHT AND APPROVED FOR USE IN WET LOCATIONS, CEC 314.15 19. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IDENTIFIED AND LISTED FOR SUCH USE, CEC 690.31(H) & 110.14. 20. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED “DO NOT DISCONNECT UNDER LOAD” OR “NOT FOR CURRENT INTERRUPTING”, CEC 690.33(C) & (E)(2). 21. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6 AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR, CEC 690.46 & 250.120(C). 22. THE INTERCONNECTION POINT SHALL BE ON THE SUPPLY SIDE OF ALL GROUND-FAULT PROTECTION EQUIPMENT, CEC 705.32. 23. CABLES/WIRES THAT ARE SUBJECT TO PHYSICAL DAMAGE, SUCH AS THOSE NOT LOCATED UNDER THE MODULES, MUST BE PROTECTED, CEC 300.4. 24. PROPOSED LOCATIONS OF ELECTRICAL SERVICE REPLACEMENTS MUST ALSO BE APPROVED BY THE ELECTRICAL UTILITY COMPANY. 25. FOR ELECTRICAL SERVICE REPLACEMENTS, BONDING TO THE METAL PIPES OF NATURAL GAS, HOT WATER, AND COLD WATER MUST BE PROVIDE, CEC 250.104. 26. GROUNDING ROD ELECTRODES SHALL BE MINIMUM 5/8’’ IN DIAMETER AND INSTALLED 8’ MINIMUM IN CONTACT WITH SOIL, CEC 250.52(A)(5), 250.53(G). 27. MINIMUM 7/8’’ CLEARANCE FROM ROOF TO BOTTOM OF CONDUIT OR USE A TEMPERATURE ADDER OF 33 DEGREES C. CEC 310.15(B)(3)(C) 28. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, & VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED OR BLOCKED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 29. EXISTING DWV PLUMBING VENT TERMINATIONS THAT ARE HORIZONTALLY LOCATED CLOSER THAN 12" FROM THE PROPOSED MODULES, MUST BE REROUTED, OR MUST BE EXTENDED A MINIMUM OF 6" ABOVE THE SURFACE OF THE MODULES, CPC 906.1. 30. EXISTING B-VENT TERMINATIONS, FOR FUEL BURNING APPLIANCES, WHERE ADJACENT TO THE PROPOSED MODULES, MUST BE EXTENDED 12" ABOVE THE MODULES' TOP SURFACE, CMC 802.6.1(1) & CPC 509.6.1(1). 31. THE MARKINGS, "WARNING: PHOTOVOLTAIC POWER SOURCE", FOR DC RACEWAYS AND CABLE ASSEMBLIES MUST BE AT 10' O.C.; AND BENDS, ABOVE OR BELOW PENETRATIONS OF ROOFS, CEILINGS, WALLS, OR BARRIERS, CEC 690.31(G)(4). 32. PV COMBINER PANELBOARDS MUST HAVE PERMANENT MARKINGS INDICATING THAT THEY ARE DEDICATED FOR PV CIRCUITS ONLY NO LOADS ARE TO BE CONNECTED. 33. WORKING CLEARANCES TO BE PROVIDED AT NEW AND EXISTING ELECTRICAL EQUIPMENT, CEC 110.26. 34. A LADDER MUST BE PROVIDED FOR INSPECTIONS IN ACCORDANCE WITH CAL-OSHA REGULATIONS, SECURED AND EXTENDING 3' ABOVE THE ROOF. 35. ALL OF THE REQUIRED MARKINGS, SIGNS, AND LABELS MUST BE INSTALLED ON ALL EQUIPMENT PRIOR TO ANY INSPECTIONS. 36. LABELS SHALL BE REFLECTIVE, AND ALL LETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUM HEIGHT OF 3/8'' IN WHITE ON A RED BACKGROUND. CEC 690.31(G)(4) 37. IDENTIFICATION OF POWER SOURCE RAPID SHUTDOWN AND LABELING SHALL BE IN ACCORDANCE WITH CEC 690.56(C). 38. WHEN THE MAIN CIRCUIT BREAKER IS DERATED, A PERMANENT MARKING MUST BE PROVIDED ON THE PANELBOARD TO INDICATE THAT THE MAIN CIRCUIT BREAKER HAS BEEN DOWNSIZED TO _______ AMPS, DO NOT UPSIZE IT. 39. PANELS AND MODULES NOT TO BE INSTALLED ON ROOF BELOW AN EMERGENCY ESCAPE AND RESCUE OPENING. CRC R324.6.2.2 40. GROUND-MOUNTED PV SYSTEMS MUST HAVE A CLEAR, BRUSH-FREE AREA OF 10-FEET AND A FIRE SEPARATION DISTANCE OF 5-FEET MINIMUM TO OTHER STRUCTURES AND PROPERTY LINES, CRC R324.7 & R302.1. 41. PLAN CHECK AND PERMIT FOR PV SYSTEM AND ASSOCIATED EQUIPMENT ONLY. 42. ALL PROJECTS SUBJECT TO FIELD VERIFICATION FOR CODE COMPLIANCE. 43. APPROVED SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED WITHIN THE DWELLING UNIT AND SHALL BE FIELD VERIFIED EITHER THROUGH FINAL BUILDING INSPECTION. SMOKE ALARMS ARE REQUIRED TO BE INSTALLED IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. R31 4.1 , R31 5.1 44. NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. APPLICABLE CODES ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES 2019 CA BUILDING CODES (CBC) 2019 CA RESIDENTIAL CODES (CRC) 2019 CA MECHANICAL CODES (CMC) 2019 CA PLUMBING CODES (CPC) 2019 CA FIRE CODES (CFC) 2019 CA ELECTRICAL CODES (CEC) 2019 CA ENERGY CODES (CEnC) 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen) SHEET INDEX A0 PROJECT INFO, VICINITY MAP, PV NOTES A1 SITE PLAN A2 MOUNTING ROOF PLAN E1 SINGLE LINE DIAGRAM E2 ELECTRICAL CALCULATIONS E3 REQUIRED SIGNAGE E4 - E4.1 MODULE DATA SHEET & CERTIFICATION E5 - E5.1 INVERTER DATA SHEET & CERTIFICATION E6 OPTIMIZER DATA SHEET S1 STANCHION DATA SHEET S2 RACKING DATA SHEET S3 - S3.3 RACKING ENGINEERING S4 RACKING GROUNDING S5 RACKING CERTIFICATION MAIN SERVICE PANEL INFORMATION EXISTING: NO UPGRADE: YES BUS RATING: (N)225A MAIN BREAKER SIZE: (N) 200A PHASE: 1PH MB POSITION: TOP # OF WIRES: 3 DERATE?: NO VOLTAGE: 240V DERATE SIZE: N/A UTILITY FED: OH METER#: 32201 0-1 1 5047 PROJECT SITE 6.252 CEC AC RATING STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 10.31.2022 REV 12-13-22 BLDG # 101113187 ISS. 12/20/2022 ELEC # 20178247 ISS. 12/20/2022 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS HUYNH RESIDENCE 6.800 DC kW 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM 2229 S LAURA LINDA LN SANTA ANA, CA 92704 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG caGIorcali@Jmail.com 323-698-4207 SP: Clean Skies Technologies AS BUILT REVISION LAYOUT CHANGE13-14-23 A1 SITE PLAN LEGEND: (E) - EXISTING (N) - NEW SITE PLAN SCALE: 1/16" = 1' (E) 1 - STORY 1212 SQ FT (N) 17 - Q.PEAK DUO BLK ML-G10+ 400 HANWHA Q CELL MODULES WITH P401 SOLAREDGE OPTIMIZERS (N) SE6000H-US (240V) SETAPP SOLAREDGE HD INVERTER (N) UPGRADE 225A MAIN SERVICE PANEL METER# 322010-115047 (N) 60A AC DISCONNECT S L A U R A L I N D A L N (E) DRIVEWAY PROPERTY LINE PR O P E R T Y L I NE PR O P E R T Y L I NE PROPERTY LINE W P E N D L E T O N A V E 1 1 STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 3.15.2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Revision to 101113187 Issued 12/20/22 101114412 Issued 03/24/23 2229 S Laura Linda Ln03/24/23 MS P D IN V 1 2 1'-6 " 1 '-6" 1 '-6" JB 278" 2.5 " MIN OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS HUYNH RESIDENCE 6.800 DC kW 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM 2229 S LAURA LINDA LN SANTA ANA, CA 92704 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 8521 0 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION REVISION DATE DRAWN1 0-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG caGIorcali@Jmail.com 323-698-4207 SP: Clean Skies Technologies AS BUILT REVISION LAYOUT CHANGE1 3-14-23 A2 MOUNTING PLAN 38 TOTAL ATTACHMENTS @ 4FT ON CENTER (N) 3/4" EMT CONDUIT RUN ABOVE ROOF OR UNDER EAVES WHERE POSSIBLE WIRING/CONDUIT RACEWAY WILL BE 7/8'' MINIMUM ABOVE THE ROOFTOP (N) 1 7 - Q.PEAK DUO BLK ML-G1 0+ 400 HANWHA Q CELL MODULES WITH P401 SOLAREDGE OPTIMIZERS STRING A - 9 MODULES STRING B - 8 MODULES 1 8 " F I R E S E T B A C K MOUNTING PLAN SCALE: 3/32" = 1 ' SOLAR PANEL DEAD WEIGHT CALCULATION MODULE HANWHA Q CELLS WIDTH (IN) LENGTH (IN) AREA (SQFT) WEIGHT (LBS) QTY TOTAL MODULE AREA TOTAL MODULE WEIGHT 41 .1 74.00 21 .1 2 48.50 1 7 359.05 824.50 RACKING IRONRIDGE RACKING WEIGHT LBS/LNFT MOUNTING SYSTEM WEIGHT TOTAL SYSTEM WEIGHT TOTAL ATTACHMENT POINTS POINT LOAD CALCS DISTRIBUTED LOAD CALCULATION .75 1 03.06 927.56 38 24.41 2.58 PSF NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 ROOF COVERAGE TOTAL MODULE AREA ROOF FACE AREA (SQFT) ROOF COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE 359.05 2695 1 3.32 1 3.32 </= 33% = OK ROOF INFORMATION ROOF TYPE SOMP SHINGLE ROOF - 2 LAYERS RAFTERS AND/OR TRUSS RAFTER SPACING (IN)ATTACHMENT SPACING 2 X 4 24" OC 48" OC FIRE ACCESS POINT AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS. A 268° AZIMUTH 1 8.5° SLOPE LEGEND (E) EXISTING (N) NEW (P) PROPOSED CONDUIT RUN VIF VERIFY IN FIELD JUNCTION BOX MAIN SERVICE PANEL AC COMBINER INVERTER AC DISCONNECT SUBPANEL SOLAR METER FIRE ACCESS POINTS FIRE PATHWAY/SETBACKS JB MSP D SP INV AC M x (N) SE6000H-US (240V) SETAPP SOLAREDGE HD INVERTER (N) UPGRADE 225A MAIN SERVICE PANEL METER# 32201 0-1 1 5047 (N) 60A AC DISCONNECT FIRE ACCESS POINT AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS. AA A A A A A AB B B B B B B B 1 8 " FI R E S E TBA C K 1 8 " F I R E S E T B A C K 1 7 8 ° A Z I M U T H 1 8 .2 ° S L OP E MODULE SIDE VIEW EVEREST CROSSRAIL 44-X EVEREST SPLICE FOOT X NOTE: MODULES WILL BE INSTALLED FLUSHED TO EXISTING ROOF SLOPE END CLAMP ASSEMBLY EVEREST K2 SOLAR SEAL BUTYL PAD ROOF ATTACHMENT DETAIL SCALE: 2" = 1 '-0" M5 X 60 LAG SCREWS 5/1 6" ‘ 2 LAGS PER ATTACHMENT 2.5" MIN EMBEDMENT 1 STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 3.15.2023 2229 S Laura Linda Ln03/24/23 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 2229 S Laura Linda Ln12/21/22 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? X l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft 2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. x YES X K2 K2 SYSTEMS 44X RAILS W/ SPLICE FOOT X ATTACHMENTS 927.56 36 25.77 48" 359.05 2.58 X Caulk 2229 S Laura Linda Ln12/21/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan                                                            6.8 KW 2229 S Laura Linda Ln12/21/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram                                                                                                                                                                                                                                                   Q.PEAK DUO BLK ML-G10+400 NEMA 3R N/A N/A N/A SE6000H-US (240V) N/A EATON DG222URB 240 200 225 35 10 6 10 4 EMT 3/4 8 1 4 1 8 1 10 3X X X 8 1 EMT 3/4 EMT 3/4 6.8KW 2229 S Laura Linda Ln12/21/22 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a)12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b)10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) HANHWA Q CELL Q.PEAK DUO BLK ML-G10+ 400 10.7 37.13 45.30 8.97 400 20 1000 -.27X SOLAREDGE SE6000H-US (240V) 480 9300 35 240 25 25 240 -7 39 x x 1 x 6.8 kw 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies E1 ELECTRICAL LINE DIAGRAM (N) SE6000H-US (240V) SOLAREDGE HD INVERTER(N) 17 - Q.PEAK DUO BLK ML-G10+400 HANWHA Q CELL MODULES WITH P401 SOLAREDGE OPTIMIZERS WITH INTEGRATED DC DISCONNECT AND AUTOMATIC RAPID SHUTDOWN UPON AC GRID DISCONNECT DC AC G AC1 WIRE/CONDUIT SCHEDULE NOTE: TERMINATE LUGS AT 75°. WIRING/CONDUIT RACEWAY WILL BE MIN 7/8'' ABOVE THE ROOF TAG DESCRIPTION CONDUCTOR TYPE/SIZE/QUANTITY CONDUIT SIZE/TYPE DC1 ARRAY TO JBOX 4 #10 AWG 2+ & 2- PV WIRE FREE AIR 1 #6 AWG GND- BARE COPPER DC2 JBOX TO INVERTER 4 #10 AWG 2+ & 2- THWN-2 3/4" EMT 1 #8 AWG GND THWN-2 AC1 INVERTER TO AC DISCONNECT 3 #10 AWG L1, L2 & N THWN-2 3/4" EMT 1 #8 AWG GND THWN-2 AC2 AC DISCONNECT TO MAIN SERVICE PANEL 3 #10 AWG L1, L2 & N THWN-2 3/4" EMT 1 #8 AWG GND THWN-2 G N AC2 EATON DG222URB 60A, 2P, 240V, TYPE DG, NON-FUSIBLE, NEMA 3R (N) 60A AC DISCONNECT (N) JB NEMA 3R ... DC2 8 9 DC1 OPTIMIZER ISC CALCULATION MAX# OF MODULES X MODULE WATTAGE 3600 = 9.00 AMPS NOMIMAL DC INPUT VOLTAGE OF INVERTER 400 (OPTIMIZER MAX OUTPUT CURRENT) [CEC 690.8] 15 > 9.00 = OK AMPS AMPS 11.14A (MODULE ISC) </= 12.5A (OPTIMIZER ISC) = OK OPTIMIZER VOC CALCULATION LARGEST MODULE VOC FOR SINGLE-MODULE DC/DC CONVERTER CONFIGURATIONS (WITH 80V AFCI CAP) (CEC 690.7 and 690.11) MODULE VOC ____ X # OF MODULES PER CONVERTER ___X CF = V MODULE VOC 45.30 TL IS GREATER THAN OR EQUAL TO -5°C, CF 1.12 MODULES PER OPTIMIZER 1.00 VOLTS 50.74 THE VALUE CALCULATED MUST BE LESS THAN OPTIMIZERS MAX DC INPUT VOLTAGE 60V > 50.74 OK OPTIMIZER SPECIFICATION MAKE SOLAREDGE 401 MAXIMUM INPUT DC POWER 430 MAX INPUT VOLTAGE (VOC)60 V SHORT CIRCUIT CURRENT (ISC)12.5 A MAX OUTPUT CURRENT 15 A MAX OUTPUT VOLTAGE 60 V MODULE SPECIFICATION MANUFACTURER HANHWA Q CELL MODEL NO.Q.PEAK DUO BLK ML-G10+ 400 PEAK POWER 400 W RATED VOLTAGE (Vmp)37.13 V RATED CURRENT (Imp)10.77 A OPEN CIRCUIT VOLTAGE (Voc)45.30 V SHORT CIRCUIT CURRENT (Isc)11.14 A INVERTER SPECIFICATION INVERTER MAKE SOLAREDGE INVERTER MODEL NO.SE6000H-US (240V) MAX INPUT VOLTAGE 480 V MAX INPUT CURRENT 16.5 A NOMIMAL AC VOLTAGE 240 V MAX AC CURRENT 25 A INTERCONNECTION COMPLIANCE PER 705 CODE MAX AC OUTPUT OF INVERTER WITH 125% MAX AC OUTPUT (AMPS) TOTAL # INVERTER TOTAL MAX AC OUTPUT 125%RESULT (AMPS) OCPD SIZE 25.00 1 25.00 1.25 31.25 35A SERVICE PANEL CALCULATIONS WITH 120% BUS RATING SIZE MUTIPLIER (120%)RESULT MAIN BREAKER INVERTER AC OUTPUT+125 % RESULT 225 1.20 270 200 31.25 231.25 270.00 >/= 231.25 = OK NOTE: 705.12(B)(2)(3) BUSBARS (B) WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. THE BUSBAR SHALL BE SIZED FOR THE LOADS CONNECTED IN ACCORDANCE WITH ARTICLE 220. A PERMANENT WARNING LABEL SHALL BE APPLIED TO THE DISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FED BREAKER FROM THE POWER SOURCE THAT DISPLAYS THE FOLLOWING OR EQUIVALENT WORDING: WARNING: POWER SOURCE OUTPUT CONNECTION — DO NOT RELOCATE THIS OVERCURRENT DEVICE. THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLY WITH 110.21(B). UPGRADE (N) 225A MAIN SERVICE PANEL 240V, 1-PH, 3W M G N (N)200A (N)35A MCB PV OCPD SCE METER# 322010- 115047 6 FT APART EARTH GROUND NOTE: 1) PV BREAKER MUST BE INSTALLED AT THE FARTHEST, OPPOSITE END OF MAIN BREAKER GROUNDING PER 250.66 CODE #4 AWG WATER BONDS - WITHIN 5FT #4 AWG MAIN BONDING JUMPER 2 GND RODS 6 FEET APART NOTE: SOLAR GROUND TYING INTO THE UFER GROUND POINT 2229 S Laura Linda Ln12/21/22 E2 ELECTRICAL CALCULATIONS OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies OPTIMIZERS SPECIFICATION MAKE SOLAREDGE P401 MAXIMUM INPUT DC POWER 430 ABSOLUTE MAX INPUT VOLTAGE (VOC)60 VDC MAX SHORT CIRCUIT CURRENT (ISC)12.5 ADC MAX OUTPUT CURRENT 15 ADC MAX OUTPUT VOLTAGE 60 ADC INVERTER SPECIFICATION INVERTER MAKE SOLAREDGE INVERTER MODEL NO.SE6000H-US (240V) MAX INPUT VOLTAGE 480 V MAX INPUT CURRENT 16.5 A NOMIMAL AC VOLTAGE 240 V MAX AC CURRENT 25 A MODULE SPECIFICATION MANUFACTURER HANHWA Q CELL MODEL NO.Q.PEAK DUO BLK ML-G10+ 400 PEAK POWER 400W RATED VOLTAGE (Vmp)37.13 V RATED CURRENT (Imp)10.77 A OPEN CIRCUIT VOLTAGE (Voc) 45.30 V SHORT CIRCUIT CURRENT (Isc) 11.14 A DC CONDUCTOR AMPACITY CALCULATIONS ARRAY TO JBOX (CEC ART 310.15) A EXPECTED WIRE TEMPERATURE (FREE AIR) 39 CELSIUS B ADD 33°C FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF 72 CELSIUS 310.15(B)(3)(C) RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS. WHERE RACEWAYS OR CABLES ARE EXPOSED TO DIRECT SUNLIGHT ON OR ABOVE ROOFTOPS, RACEWAYS OR CABLES SHALL BE INSTALLED A MINIMUM DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR CABLE OF 23 MM (7∕8 IN.). TEMPERATURE CORRECTION FACTOR CEC TABLE 310.15 (B)(2)(A)0.91 WIRING/CONDUIT RACEWAY WILL BE EQUAL TO 7/8'' OR MORE ABOVE THE ROOFTOP PER CEC 310.15(B)(3)(c) C # OF CURRENT CARRYING CONDUCTORS 4 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) D CONDUIT FILL CORRECTION 0.80 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) E CIRCUIT CONDUCTOR SIZE #10 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) F CIRCUIT CONDUCTOR AMPACITY@75°35 AMPS CEC TABLE 310.15 (B)(16) G REQUIRED CIRCUIT CONDUCTOR AMPACITY 15 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY = MAXIMUM OPTIMIZER OUTPUT CURRENT (AMPS) (FROM OPTIMIZERS SPECIFICATIONS) H DERATED AMPACITY OF CIRCUIT CONDUCTOR 25.48 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "H" MUST BE LARGER THAN "G" 25.48A > 15A = OK DC CONDUCTOR AMPACITY CALCULATIONS FROM JUNCTION BOX TO INVERTER A AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 39 CELSIUS 310.15(B)(3)(C) RACEWAYS AND CABLES EXPOSED TO SUNLIGHT ON ROOFTOPS. WHERE RACEWAYS OR CABLES ARE EXPOSED TO DIRECT SUNLIGHT ON OR ABOVE ROOFTOPS, RACEWAYS OR CABLES SHALL BE INSTALLED A MINIMUM DISTANCE ABOVE THE ROOF TO THE BOTTOM OF THE RACEWAY OR CABLE OF 23 MM (7∕8 IN.). TEMPERATURE CORRECTION FACTOR 0.91 WIRING/CONDUIT RACEWAY WILL BE EQUAL TO 7/8'' OR MORE ABOVE THE ROOFTOP PER CEC 310.15(B)(3)(c) # OF CURRENT CARRYING CONDUCTORS 4 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) CONDUIT FILL CORRECTION 0.80 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) CIRCUIT CONDUCTOR SIZE #10 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) CIRCUIT CONDUCTOR AMPACITY@75°35 AMPS CEC TABLE 310.15 (B)(16) B REQUIRED CIRCUIT CONDUCTOR AMPACITY 15 AMPS REQUIRED CIRCUIT CONDUCTOR AMPACITY = MAXIMUM OPTIMIZER OUTPUT CURRENT (AMPS) (FROM OPTIMIZERS SPECIFICATIONS) C DERATED AMPACITY OF CIRCUIT CONDUCTOR 25.48 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "C" MUST BE LARGER THAN "B" 25.48A > 15.00A = OK AC CONDUCTOR AMPACITY CALCULATIONS BETWEEN INVERTER TO MAIN ELECTRICAL PANEL A AMBIENT TEMPERATURE ADJUSTMENT EXPOSED CONDUIT 39 CELSIUS (ADD 22° OR 4O° FOR CONDUITS EXPOSED TO SUNLIGHT ON OR ABOVE ROOF) CEC TABLE 310.15 (B)(2)(A) & CEC TABLE 310.15 (B)(2)(C) EXPECTED WIRE TEMPERATURE TEMPERATURE CORRECTION FACTOR 0.91 CEC TABLE 310.15 (B)(2)(A) # OF CURRENT CARRYING CONDUCTORS 2 (UP TO 8 CONDUCTORS IN ROOF MOUNTED CONDUITS EXPOSED TO SUNLIGHT) CONDUIT FILL CORRECTION 1.00 .80 (FOR 4 TO 6 CONDUCTORS IN CONDUIT) OR 1.00 (FOR 3 OR LESS CONDUCTORS IN CONDUIT) CEC TABLE 310.15 (B)(3)(A) CIRCUIT CONDUCTOR SIZE #10 AWG MINIMUM #10 AWG CU, 90°C WET (USE-2, PV WIRE, THWN-2, RHW-2) CIRCUIT CONDUCTOR AMPACITY @ 90° 40 AMPS CEC TABLE 310.15 (B)(16) INVERTER'S MAXIMUM AC OUPUT CURRENT 25 AMPS INVERTER MANUFACTURER SPECIFICATIONS B REQUIRED AC CONDUCTOR AMPACITY 31.25 AMPS REQUIRED AC CONDUCTOR AMPACITY =1.25 X MAXIMUM INVERTER'S OUTPUT CURRENT (AMPS) C DERATED AMPACITY OF CIRCUIT CONDUCTORS 36.40 AMPS TEMPERATURE CORRECTION X CONDUIT FILL CORRECTION X CIRCUIT CONDUCTOR AMPACITY CEC TABLE 310.15 (B)(2)(A) NOTE: "C" MUST BE GREATER THAN "B" 36.40A > 31.25A = OK LOCATION INFORMATION SOLAR ABC ASHRAE NEC TABLE 310.15 (B)(2)(a)-TEMP CORRECTION FACTORS WIRE TERMINATIONS AT 75° AMPACITY HIGH TEMP 39 °C LOW TEMP -7 °C VOLTAGE CORRECTION FACTOR -TABLE 690.7(A)1.12 ROOF TEMP + 33°-IF RACEWAY CONDUIT IS LESS THAN 7/8" ABOVE ROOF 72 °C TEMP CORRECTION FACTOR (ABOVE ROOF)0.65 TEMP CORRECTION FACTOR (INSIDE CONDUIT)0.91 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies E3 REQUIRED SIGNAGE SIGNS AND LABEL - CENTRAL/STRING INVERTER SYSTEMS CEC ARTICLES 690 AND 705 AND CA RESIDENTIAL CODE SECTION R324 REQUIRE THE FOLLOWING LABELS OR MARKINGS BE INSTALLED AT THESE COMPONENTS OF THE PHOTOVOLTAIC SYSTEM: DIRECTORY PLACARD · ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. · THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. · MARKING IS PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERE THE DISCONNECT IS OPERATED. · THE MARKINGS SAY WARNING: PHOTOVOLTAIC POWER SOURCE AND HAVE 3/8-INCH (9.5 MM) MINIMUM-SIZED WHITE LETTERS ON A RED BACKGROUND. THE SIGNS ARE MADE OF REFLECTIVE WEATHER RESISTANT MATERIAL. · WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. · REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. SIGNAGE NOTES: K MAIN SERVICE PANEL 6" 5" INVERTER CAUTION POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN S L A U R A L I N D A L N DR I VE W A Y AC DISCO ADDRESS: 2229 S LAURA LINDA LANE INVERTER DC DISCO PV ARRAY JBOX A A GC M MAIN SERVICE PANELAC DISCO C G I JH E F DC B K NEC 690.13(B) I J D RATED AC OUTPUT CURRENT NORMAL OPERATING VOLTAGE A V NEC 690.54 PHOTOVOLTAIC AC DISCONNECT NEC 690.56 (C)(3) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM REQUIRED AT LOCATION ON OR NO MORE THAN 1 METER (3 FT) FROM THE SWITCH 25 240 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS NEC 690.56(C)(1) WARNING: PHOTOVOLTAIC POWER SOURCE NEC 705.12 (B)(2)(c) A NEC 690.31(G)(3)(4) F C E B !PV SYSTEM DISCONNECT G NEC 690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT NEC 705.12(B)(3-4) & NEC 690.59 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING ! ! WARNING ! ! TERMINAL ON THE LINE AND LOAD SIDES MAY BE ENGERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD DIRECT CURRENT PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE VDC MAXIMUM CIRCUIT CURRENT AMPS MAXIMUM RATED DC TO DC CONVERTER OUTPUT AMPS NEC 690.53 480 16.5 15 H WARNING ! ! SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM DUAL POWER SUPPLY IF THERE IS NO INVERTER PLACE LABEL ON COMBINER BOX, IF THERE IS NO COMBINER BOX PLACE ON MAIN SERVICE PANEL. DIRECTORY PLACARD K ALL ROOF CONDUIT NEC 705.10 & NEC 690.56(B) REQUIRES A PERMANENT PLAQUE OR DIRECTORY DENOTING ALL ELECTRIC POWER SOURCE ON OR IN THE PREMISES OR RAPID FIRE SHUTDOWN EQUIPMENT; INSTALL AT MAIN SERVICE PANEL SOLAR ARRAYS 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE JOBSITE ADDRESS HUYNH RESIDENCE 6.800 DC kW 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM 2229 S LAURA LINDA LN SANTA ANA, CA 92704 CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG caGIorcali@Jmail.com 323-698-4207 SP: Clean Skies Technologies AS BUILT REVISION LAYOUT CHANGE13-14-23 E3 REQUIRED SIGNAGE SIGNS AND LABEL - CENTRAL/STRING INVERTER SYSTEMS CEC ARTICLES 690 AND 705 AND CA RESIDENTIAL CODE SECTION R324 REQUIRE THE FOLLOWING LABELS OR MARKINGS BE INSTALLED AT THESE COMPONENTS OF THE PHOTOVOLTAIC SYSTEM: DIRECTORY PLACARD · ALL INTERIOR AND EXTERIOR DC CONDUIT, ENCLOSURES, RACEWAYS, CABLE ASSEMBLIES, JUNCTION BOXES, COMBINER BOXES AND DISCONNECTS ARE MARKED. · THE MARKINGS ON THE CONDUITS, RACEWAYS AND CABLE ASSEMBLIES ARE EVERY 10 FEET, WITHIN ONE FOOT OF ALL TURNS OR BENDS AND WITHIN ONE FOOT ABOVE AND BELOW ALL PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS AND BARRIERS. · MARKING IS PLACED ADJACENT TO THE MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM WHERE THE DISCONNECT IS OPERATED. · THE MARKINGS SAY WARNING: PHOTOVOLTAIC POWER SOURCE AND HAVE 3/8-INCH (9.5 MM) MINIMUM-SIZED WHITE LETTERS ON A RED BACKGROUND. THE SIGNS ARE MADE OF REFLECTIVE WEATHER RESISTANT MATERIAL. · WHERE PV CIRCUITS ARE EMBEDDED IN BUILT-UP, LAMINATE OR MEMBRANE ROOFING MATERIALS IN ROOF AREAS NOT COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT, THE LOCATION OF CIRCUITS SHALL BE CLEARLY MARKED. · REQUIRED LABELS SHALL BE PERMANENT AND SUITABLE FOR THE ENVIRONMENT. SIGNAGE NOTES: K MAIN SERVICE PANEL 6" 5" INVERTER CAUTION POWER TO THIS BUILDING ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN S L A U R A L I N D A L N DR I V E W A Y AC DISCO ADDRESS: 2229 S LAURA LINDA LANE INVERTER DC DISCO PV ARRAY JBOX A A GC M MAIN SERVICE PANELAC DISCO C G I JH E F DC B K NEC 690.13(B) I J D RATED AC OUTPUT CURRENT NORMAL OPERATING VOLTAGE A V NEC 690.54 PHOTOVOLTAIC AC DISCONNECT NEC 690.56 (C)(3) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM REQUIRED AT LOCATION ON OR NO MORE THAN 1 METER (3 FT) FROM THE SWITCH 25 240 SOLAR PV SYSTEM EQUIPPED WITH RAPI D SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS NEC 690.56(C)(1) WARNING: PHOTOVOLTAIC POWER SOURCE NEC 705.12 (B)(2)(c) A NEC 690.31(G)(3)(4) F C E B !PV SYSTEM DISCONNECT G NEC 690.13(B) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT NEC 705.12(B)(3-4) & NEC 690.59 POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE WARNING ! ! WARNING ! ! TERMINAL ON THE LINE AND LOAD SIDES MAY BE ENGERGIZED IN THE OPEN POSITION ELECTRIC SHOCK HAZARD DIRECT CURRENT PHOTOVOLTAIC POWER SOURCE MAXIMUM VOLTAGE VDC MAXIMUM CIRCUIT CURRENT AMPS MAXIMUM RATED DC TO DC CONVERTER OUTPUT AMPS NEC 690.53 480 16.5 15 H WARNING ! ! SOURCES: UTILITY GRID AND PV SOLAR ELECTRI CSYSTEM DUAL POWER SUPPLY IF THERE IS NO INVERTER PLACE LABEL ON COMBINER BOX, IF THERE IS NO COMBINER BOX PLACE ON MAIN SERVICE PANEL. DIRECTORY PLACARD K ALL ROOF CONDUIT NEC 705.10 & NEC 690.56(B) REQUIRES A PERMANENT PLAQUE OR DIRECTORY DENOTING ALL ELECTRIC POWER SOURCE ON OR IN THE PREMISES OR RAPID FIRE SHUTDOWN EQUIPMENT; INSTALL AT MAIN SERVICE PANEL SOLAR ARRAYS 1 2229 S Laura Linda Ln03/24/23 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies E4 MODULE DATA SHEET 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies E4.1 MODULE CERTIFICATION 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies E5 INVERTER DATA SHEET 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies E5.1 INVERTER CERTIFICATION 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies E6 OPTIMIZER DATA SHEET 2229 S Laura Linda Ln12/21/22 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies A1 SITE PLAN LEGEND: (E) - EXISTING (N) - NEW SITE PLAN SCALE: 1/16" = 1' (E) 1 - STORY 1212 SQ FT (N) 17 - Q.PEAK DUO BLK ML-G10+ 400 HANWHA Q CELL MODULES WITH P401 SOLAREDGE OPTIMIZERS (N) SE6000H-US (240V) SETAPP SOLAREDGE HD INVERTER (N) UPGRADE 225A MAIN SERVICE PANEL METER# 322010-115047 (N) 60A AC DISCONNECT S L A U R A L I N D A L N (E) DRIVEWAY PROPERTY LINE PR O P E R T Y L I N E PR O P E R T Y LI N E PROPERTY LINE W P E N D L E T O N A V E STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 10.31.2022 2229 S Laura Linda Ln12/21/22 MS P D IN V 1 2 1 '-6"1 '-6" 1 '-6" JB 278" 2.5" MIN OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 8521 0 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN1 0-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies A2 MOUNTING PLAN 36 TOTAL ATTACHMENTS @ 4FT ON CENTER (N) 3/4" EMT CONDUIT RUN ABOVE ROOF OR UNDER EAVES WHERE POSSIBLE WIRING/CONDUIT RACEWAY WILL BE 7/8'' MINIMUM ABOVE THE ROOFTOP (N) 17 - Q.PEAK DUO BLK ML-G10+ 400 HANWHA Q CELL MODULES WITH P401 SOLAREDGE OPTIMIZERS STRING A - 9 MODULES STRING B - 8 MODULES 18" F I R E SET BAC K MOUNTING PLAN SCALE: 3/32" = 1' SOLAR PANEL DEAD WEIGHT CALCULATION MODULE HANWHA Q CELLS WIDTH (IN) LENGTH (IN) AREA (SQFT) WEIGHT (LBS) QTY TOTAL MODULE AREA TOTAL MODULE WEIGHT 41.1 74.00 21.12 48.50 17 359.05 824.50 RACKING IRONRIDGE RACKING WEIGHT LBS/LNFT MOUNTING SYSTEM WEIGHT TOTAL SYSTEM WEIGHT TOTAL ATTACHMENT POINTS POINT LOAD CALCS DISTRIBUTED LOAD CALCULATION .75 103.06 927.56 36 25.77 2.58 PSF NOTE: THE POINT LOADING AND DISTRIBUTED LOADING SHOULD BE MAX 5 LBS/FT2 ROOF COVERAGE TOTAL MODULE AREA ROOF FACE AREA (SQFT) ROOF COVERAGE COMPLIANCE WITH R324.6.2 SET BACK AT RIDGE 359.05 2695 13.32 1 3.32 </= 33% = OK ROOF INFORMATION ROOF TYPE SOMP SHINGLE ROOF - 2 LAYERS RAFTERS AND/OR TRUSS RAFTER SPACING (IN)ATTACHMENT SPACING 2 X 4 24" OC 48" OC FIRE ACCESS POINT AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS. A 268° AZIMUTH 1 8.5° SLOPE LEGEND (E) EXISTING (N) NEW (P) PROPOSED CONDUIT RUN VIF VERIFY IN FIELD JUNCTION BOX MAIN SERVICE PANEL AC COMBINER INVERTER AC DISCONNECT SUBPANEL SOLAR METER FIRE ACCESS POINTS FIRE PATHWAY/SETBACKS JB MSP D SP INV AC M x (N) SE6000H-US (240V) SETAPP SOLAREDGE HD INVERTER (N) UPGRADE 225A MAIN SERVICE PANEL METER# 322010-115047 (N) 60A AC DISCONNECT FIRE ACCESS POINT AREA NOT TO BE OVER ANY DOORS, WINDOWS OR OTHER OBSTRUCTIONS. A A A A A A A A B B B B B B B B 18" FI R E SET B A C K 18" FI R E S E T B A C K 1 7 8° A Z I M U T H 1 8 . 2 ° SL O P E MODULE SIDE VIEW EVEREST CROSSRAIL 44-X EVEREST SPLICE FOOT X NOTE: MODULES WILL BE INSTALLED FLUSHED TO EXISTING ROOF SLOPE END CLAMP ASSEMBLY EVEREST K2 SOLAR SEAL BUTYL PAD ROOF ATTACHMENT DETAIL SCALE: 2" = 1'-0" M5 X 60 LAG SCREWS 5/1 6" Ø 2 LAGS PER ATTACHMENT 2.5" MIN EMBEDMENT STRUCTURAL ONLY www.vincise.com S T R U C T U R A L E N G I N E E R S 10.31.2022 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies S1 STANCHION DATA SHEET 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies S2 RACKING DATA SHEET 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies S3 RACKING ENGINEERING 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies S3.1 RACKING ENGINEERING 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies S3.2 RACKING ENGINEERING 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies S3.3 RACKING ENGINEERING 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies S4 GROUNDING DATA SHEET 2229 S Laura Linda Ln12/21/22 OWNER SHEET TITLE SHEET NUMBER PROJECT TITLE HUYNH RESIDENCE CONTRACTOR TITAN SOLAR POWER CA INC 525 W BASELINE ROAD MESA, AZ 85210 (855) 729-7652 WWW.TITANSOLARPOWER.COM PROJECT ID# TSP145775 DATE DESCRIPTION 6.252 KW CEC-AC RATING STRING INVERTER SYSTEM JOBSITE ADDRESS 2229 S LAURA LINDA LN SANTA ANA, CA 92704 REVISION DATE DRAWN10-23-22 DESIGN BY: RD CAD F O R C A L I I N C . SHELLEY V CALUAG cadforcali@gmail.com 323-698-4207 SP: Clean Skies Technologies S5 RACKING CERTIFICATION 2229 S Laura Linda Ln12/21/22 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Titan Solar Power CA 1062072 Guillermo Vasquez 626-602-5493 capermitting@titansolarpower.com 11/16/22 2229 S Laura Linda Ln 2229 S Laura Linda Ln12/21/22 -.e Planning & Building Agency Permits & Plan Check Section 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)647-5800 EXISTING ONE & TWO FAMILY DWELLINGS ELECTRICAL SERVICES UNDERGROUND EXCEPTION CEC 2019 ELC-04 All new utility connections are required to be installed below grade by Santa Ana Municipal Code 41- 626(b). There is a standing exception for existing one and two family dwellings. This exception applies only when the new electrical service is designed to be fed from below grade as well as overhead. This diagram is a typical unit. The utility is able to feed this cabinet from the top or the bottom without interfering with the distribution wiring. All the circuit breakers and branch circuits are contained in the circuit breaker side of this cabinet. Only listed combination overhead and underground feed service boxes may be used to connect to an overhead utility drop. This exception to an underground fed service applies only to existing single family and two family residences. Rigid New service Conduit location may NOT Service Entrance be under a patio Conductor fl cover structure. Riser -SCE METER PC��I�C�P ' Future Underground Service Lateral A surface -mounted combination service rquires no raceway provision for future underground feed. When new service is semi -flush or flush mounted, a 3 inch rigid raceway is needed. Cap straight stub - out at a depth of 12 inches below grade. A sweep is capped at 30 inches below grade. Rev. 1/21/2020 wwwsanta-ana.org/pba/ Page 1 of 1 City of Santa Ana, CA, Department of Building & Safety Subject: Review of PV Array installed on Existing Residence Project: Huynh 2229 S Laura Linda Ln Santa Ana, CA V&A Project No. 22-3457 We have reviewed the existing home for the proposed PV array installation. Based upon our analysis, we have found that the existing home is sufficient to support the added load of the PV array. Analysis based upon: 2019 CBC Our professional services have been performed using the degree of care and skill ordinarily exercised under similar circumstances by reputable engineers practicing in this locality. No other warranty, expressed or implied, is made as to the professional options included in this report. We hope this provides you with the information you need at this time. Please call us if you have any questions regarding this report. Sincerely, VINCI & ASSOCIATES James R. Vinci, S.E. License No. S-4411 V I N C I & A S S O C I A T E S Structural Engineers 10/31/2022 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 805.496.2100 • VinciSE.com 10/31/2022 2229 S Laura Linda Ln12/21/22 V I N C I & A S S O C I A T E S Structural Engineers STRUCTURAL CALCULATIONS FOR PHOTOVOLTAIC Santa Ana, CA CLIENT: Titan Solar Power 805.496.2100 • VinciSE.com 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ARRAY JOB NO: 22-3457 Huynh 2229 S Laura Linda Ln 2229 S Laura Linda Ln12/21/22 DATE:V I N C I & A S S O C I A T E S SHEET:1 PROJECT:Huynh Structural Engineers JOB NO.:22-3457 2229 S Laura Linda Ln 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power DESIGN DATA: ROOF DESIGN LOAD: ROOFING ( Composition Shingle )=5 psf SHEATHING =2 ROOF RAFTERS / TRUSS =2 MISCELLANEOUS =1 ROOF RAFTER/TRUSS DESIGN DEAD LOAD = 10.0 psf CEILING & INSULATION =3.25 MISCELLANEOUS =1.25 DESIGN DEAD LOAD =14.5 psf DESIGN LIVE LOAD =20 psf DESIGN SNOW LOAD =0 psf WIND DESIGN CRITERIA: BASIC WIND SPEED =100 mph WIND EXPOSURE =C NUMBER OF STORIES =1 ROOF SLOPE =19° SOLAR MODULE Solar Module Width:=41.1 in Solar Module Length:=74 in Solar Module Area =21.12 ft2 Solar Module Dead Load =2.58 psf Number of PV Modules =17 Number of Mounts to Roof =36 Maximum Spacing of Mounts =4 ft o.c. Tributary Area to Mounts 21.12 ft2 x ( 17 /36 ) = 9.97 ft2 (Average) ( 4 ft oc x 74 in / 12''/ft ) / 2 =12.33 ft2 (Worst Case) Solar Module Vertical Support Point Load 12.33 ft2 x 2.58 psf = 31.8 lbs TOTAL AREA OF ADDED SOLAR PANELS ( 3.43 ft x 6.17 ft ) x ( 17 Modules ) = 359.1 ft2 10/31/2022 -2229 S Laura Linda Ln12/21/22 DATE:V I N C I & A S S O C I A T E S SHEET:2 PROJECT:Huynh Structural Engineers JOB NO.:22-3457 2229 S Laura Linda Ln 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power DESIGN CONNECTION TO ROOF TO RESIST WIND UPLIFT REFER TO NEXT SHEET FOR UPLIFT FORCE CALCULATIONS ZONE 1 UPLIFT = -.6(2.58psf) Design Force = ( Uplift x (0.6) ) -.6(2.58psf) Net Uplift = ADD 2.12 Connections per Module (MIN) CONNECTION 17 Modules, 36 Connections DETAIL Max Trib Area =ft2 HERE UPLIFT / CONN. = 12.3 ft2 x 8.1 psf = 99.31 lbs/conn PER 2018 NDS (TABLE 12.2A) PALLOW = 256 lbs/in x CD x Ct for (1) screw WITH 2.00'' PENETRATION INTO JOIST PALLOW = 2.00 '' x 410 lbs/in = 819.2 lbs > 99 lbs Therefore O.K. FACTOR OF SAFETY: F.O.S. = 8.25 > 1.5 Therefore O.K. ZONE 3 UPLIFT = - 0.6 (2.58 psf)ZONE 2 UPLIFT = -.6(2.58psf) Design Force = ( Uplift x (0.6) ) - 0.6 (2.58 psf)Design Force = ( Uplift x (0.6) ) -.6(2.58psf) Net Uplift = Net Uplift = 2.12 Connections per Module (MIN)2.12 Connections per Module (MIN) 17 Modules, 36 Connections 17 Modules, 36 Connections Max Trib Area = ft2 Max Trib Area = ft2 UPLIFT / CONN. = 8.226 ft2 x UPLIFT / CONN. = 12.33 ft2 x = 229.9 lbs/conn = 344.7 lbs/conn PER 2018 NDS (TABLE 12.2A)PER 2018 NDS (TABLE 12.2A) PALLOW = 256 lbs/in x CD x Ct PALLOW = 256 lbs/in x CD x Ct for (1) screw for (1) screw WITH 2.00'' PENETRATION INTO JOIST WITH 2.00'' PENETRATION INTO JOIST PALLOW = 2.00 '' x 409.6 lbs/in PALLOW = 2.00 '' x 410 lbs/in = 819.2 lbs > = 819.2 lbs > Therefore O.K.Therefore O.K. FACTOR OF SAFETY:FACTOR OF SAFETY: F.O.S. = 3.56 > 1.5 F.O.S. = 2.38 > 1.5 - 12.33 5/16 in 5/16 in 12.33 27.9 psf 10/31/2022 8.1 psf 16.0 psf 49.2 psf 49.2 psf 27.9 psf 345 lbs 27.9 psf 5/16 in 8.23 Therefore O.K. 27.9 psf 230 lbs Therefore O.K. 2229 S Laura Linda Ln12/21/22 DATE:V I N C I & A S S O C I A T E S SHEET:3 PROJECT:Huynh Structural Engineers JOB NO.:22-3457 2229 S Laura Linda Ln 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com Company Titan Solar Power Wind Analysis Per ASCE 7-16 - Components and Cladding Exposure Category : C Importance Factor : 1 Basic Wind Speed : 100 Topographical factor : 1 Flat Bldg Ht to eave : 10 ft2 Bldg Ht to Ridge : 15 ft Bldg L : 50 ft Bldg W : 45 ft Effective area : 359.05 ft2 a = 3 (width of edge strips, ASCE 7, 28.3-1) Design pressures for Roof Top Solar Panels qh = 18.50 psf (q h = 0.00256K z K zt K d K e V 2 ) (ASCE 7, 26.10) G Cp = External pressure coefficient ASCE 7, 30.3.2) G Cpi = 0.18 or -0.18 (ASCE 7, 26.13-1, Enclosed Building) Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r Zone 3 Zone 3e Zone 3r Zone 4 Zone 5 G Cp 0.30 - - 0.30 0.30 0.30 - 0.30 0.30 0.70 0.70 -G Cp -0.50 - - -0.50 -2.48 -2.48 - -2.48 -1.80 -0.80 0.00 Roof Top Solar Panels (psf)Zone 1 Max Pressure = -5.55 psf ƳΕ = 1.5 (ASCE 7, 29.4-7)Zone 2 Max Pressure = -27.50 psf (USING WORST CASE EDGE FACTOR)Zone 3 Max Pressure = -27.50 psf p = qh (GCp ) (ƳΕ) (Ƴα)(ASCE 7, 29.4.4) Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r Zone 3 Zone 3e Zone 3r Zone 4 Zone 5 Positive 3.33 3.33 3.33 3.33 3.33 3.33 7.77 7.77 Negative -5.55 -5.55 -27.50 -27.50 -27.50 -19.98 -8.88 0.00 Components and Cladding Pressure (psf) Zone 1 Max Pressure = -16.00 psf GOVERNS Zone 2 Max Pressure = -49.16 psf GOVERNS Zone 3 Max Pressure = -49.16 psf GOVERNS p = qh [(G Cp ) - (G Cpi)](pressure on component, ASCE 7, 30.3-1) p (min) = 16 psf (ASCE 7, 30.2.2) Zone 1 Zone 1' Zone 2 Zone 2e Zone 2n Zone 2r Zone 3 Zone 3e Zone 3r Zone 4 Zone 5 Positive 16.00 16.00 16.00 16.00 16.00 16.00 19.69 19.69 Negative -16.00 -16.00 -49.16 -49.16 -49.16 -36.62 -21.93 -21.93 10/31/2022 - 2229 S Laura Linda Ln12/21/22 DATE:V I N C I & A S S O C I A T E S SHEET:4 PROJECT:Huynh Structural Engineers JOB NO.:22-3457 2229 S Laura Linda Ln 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power LATERAL FORCES: (Base Shear Calculations - 2019 CBC / ASCE-16 ) SEISMIC: Site Class: D (Use D if unknown) S1= 0.464 (USGS Software)SS= 1.30 (USGS Software) Fv = 1.7 (Table 1613.3.3(2))Fa = 1.2 (Table 1613.3.3 (1)) I = 1.0 (Table 11.5-1) R = 6.5 (Table 12.2-1) SMS = Fa * SS = 1.555 (Eq. 16-37)SDS = (Eq. 16-39) SM1= Fv * S1 = 0.789 (Eq. 16-38)SD1 = (Eq. 16-40) TL = 8 s (Figure 22-12) T = Ct * (hn)x = (Eq. 12.8-7)Ct = 0.02 (Table 12.8-2) hn = 10.0 ft x = 0.75 (Table 12.8-2) * *GOVERNS * * VMIN = ( SDS) / ( R / I ) =0.16 W (Eq. 12.8-2) NEED NOT EXCEED: IF T ≤ TL USE: V = ( SD1) / T *( R / I ) =W (Eq. 12.8-3) IF T TL USE: V = ( SD1)*(TL) / T² *( R / I ) =W (Eq. 12.8-4) SHALL NOT BE LESS THAN: V = W (Eq. 12.8-5)0.01 51.17 0.72 10/31/2022 0.112 s 1.04 0.53 ²/3 * SMS = ²/3 * SM1 = 2229 S Laura Linda Ln12/21/22 10/31/22, 2:43 PM U.S. Seismic Design Maps https://www.seismicmaps.org 1/2 2229 S Laura Linda Ln, Santa Ana, CA 92704, USA Latitude, Longitude: 33.71671, -117.8999777 Date 10/31/2022, 2:42:52 PM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description SS 1.296 MCE R ground motion. (for 0.2 second period) S1 0.464 MCE R ground motion. (for 1.0s period) SMS 1.556 Site-modified spectral acceleration value SM1 null -See Section 11.4.8 Site-modified spectral acceleration value SDS 1.037 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.554 MCE G peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.665 Site modified peak ground acceleration T L 8 Long-period transition period in seconds SsRT 1.296 Probabilistic risk-targeted ground motion. (0.2 second) SsUH 1.404 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 1.74 Factored deterministic acceleration value. (0.2 second) S1RT 0.464 Probabilistic risk-targeted ground motion. (1.0 second) S1UH 0.502 Factored uniform-hazard (2% probability of exceedance in 50 years) spectral acceleration. S1D 0.6 Factored deterministic acceleration value. (1.0 second) PGAd 0.713 Factored deterministic acceleration value. (Peak Ground Acceleration) PGAUH 0.554 Uniform-hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration CRS 0.924 Mapped value of the risk coefficient at short periods CR1 0.924 Mapped value of the risk coefficient at a period of 1 s CV 1.359 Vertical coefficient 2229 S Laura Linda Ln12/21/22 DATE:V I N C I & A S S O C I A T E S SHEET:6 PROJECT:Huynh Structural Engineers JOB NO.:22-3457 2229 S Laura Linda Ln 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power LATERAL FORCES:(BASE SHEAR - Conservative) 2019 CBC F1 SEISMIC BASE SHEAR: V = 0.16 W (SEE PREVIOUS)h1 = 10.0 ft F1 ROOF = 15 PSF WALLS = 7 21.3 x 0.160 3.39 PSF WIND LOADS: Governs ps = λ kzt Iw ps30 (Eq. 6-1) λ = 1.21 ps30A = psf psA psf I w =1.00 ps30B = psf psB psf kzt = 1.00 ps30C =psf psC psf ps30D =psf psD psf F1ULT:= ( 5 ft + 10 ft /2 ) x (23.2704 psf +12.12 psf )= 354 lb/ft F1ASD:= lb/ft x 0.6 = 212 lb/ft -10.00 12.70 -5.90 10/31/2022 hROOF= - 353.90 5.0 ft 23.27 -12.12 15.39 -7.15 19.20 2229 S Laura Linda Ln12/21/22 DATE:V I N C I & A S S O C I A T E S SHEET:7 PROJECT:Huynh Structural Engineers JOB NO.:22-3457 2229 S Laura Linda Ln 175 E. WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 ENGR.:JRV Santa Ana, CA 805.496.2100 • VinciSE.com CLIENT:Titan Solar Power CHECK IMPACT OF NEW SOLAR PANELS ON SEISMIC LOAD ADD ROOF PLAN HERE TOTAL ROOF AREA: ( 50.0 ft x 45.0 ft ) + ( 0.0 ft x 0.0 ft ) + ( 0.0 ft x 0.0 ft ) + ( 0.0 ft x 0.0 ft ) = EXISTING ESTIMATED SEISMIC LOAD (BASE SHEAR) 2250 ft2 x 3.39 psf = 7628.46 lbs AREA OF ADDED SOLAR PANELS (PER PAGE 1)= ft2 WEIGHT OF PANELS: 2.58 psf ADDED SEISMIC LOAD: 2.58 psf x ft2 x 0.16 =147.8 lbs Therefore O.K. Per CEBC SECTION 503.4 359.1 359.1 =1.9% < 10%% INCREASE =147.8 7628.455385 10/31/2022 - 2250 ft2 2229 S Laura Linda Ln12/21/22 Check Top Chord of Existing Truss Oct. 31, 2022 14:44 Design Check Calculation Sheet WoodWorks Sizer 2019 (Update 4) Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Roof-DL Dead Full Area No 10.00(24.0") psf Roof-LLR Roof constr. Full Area Yes 20.00(24.0") psf PV1 Dead Point No 0.50 32 lbs PV2 Dead Point No 5.50 32 lbs PV3 Dead Point No 7.00 32 lbs PV4 Dead Point No 12.00 32 lbs Self-weight Dead Full UDL No 1.2 plf Maximum Reactions (lbs) and Bearing Lengths (in) : 1.5' 8.5' 16.32' 15.5' Unfactored: Dead 148 255 71 Roof Live 191 343 126 Factored: Total 340 599 198 Bearing: Length 0.50* 0.51 0.50* Min req'd 0.50* 0.51** 0.50* *Minimum bearing length setting used: 1/2" for end supports and 1/2" for interior supports **Minimum bearing length governed by the required width of the supporting member. Lumber-soft, D.Fir-L, No.2, 2x4 (1-1/2"x3-1/2") Supports: All - Timber-soft Beam, D.Fir-L No.2 Roof joist spaced at 24.0" c/c; Total length: 16.44'; Clear span(horz): 1.5', 6.938', 6.938'; Volume = 0.6 cu.ft.; Slope: 18.0 deg Lateral support: top = continuous, bottom = at all supports; Repetitive factor: applied where permitted (refer to online help); This section PASSES the design code check. Analysis vs. Allowable Stress and Deflection using NDS 2018 : Criterion Analysis Value Design Value Unit Analysis/Design Shear fv = 80 Fv' = 225 psi fv/Fv' = 0.36 Bending(+) fb = 1162 Fb' = 1941 psi fb/Fb' = 0.60 Bending(-) fb = 1673 Fb' = 1824 psi fb/Fb' = 0.92 Deflection: Interior Dead 0.08 = < L/999 Live 0.20 = L/434 0.37 = L/240 in 0.55 Total 0.29 = L/306 0.49 = L/180 in 0.59 Cantil. Dead -0.03 = L/585 Live -0.14 = L/132 0.16 = L/120 in 0.91 Total -0.18 = L/107 0.21 = L/90 in 0.84 2229 S Laura Linda Ln12/21/22