Loading...
HomeMy WebLinkAbout2429 W Hood Ave #2 - Plan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alifornia Residential Code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ç ç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ķ ķ */RZ5LVH5HVLGHQWLDO0HDVXUHV ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=ķ *7(QHUJ\$QDO\VLV&=(DVW ķ *7(QHUJ\$QDO\VLV&=1RUWK ķ *7(QHUJ\$QDO\VLV&=6RXWK ķ *7(QHUJ\$QDO\VLV&=:HVW ķ *7(QHUJ\$QDO\VLV&=ķ $UFKLWHFWXUDO $6LWH3ODQ $)RXQGDWLRQ3ODQ ķ ķ $)ORRUDQG5RRI3ODQ ķ $([WHULRU(OHYDWLRQV ķ $6HFWLRQV ķ $([WHULRU'HWDLOV ķ $6FKHGXOHV ķ $ 2SWLRQDO +U)LUH5DWHG'HWDLO ķ ķ 6WUXFWXUDO 66WUXFWXUDO7LWOH6KHHW ķ ķ 66WUXFWXUDO6SHFLILFDWLRQV ķ ķ 6)RXQGDWLRQ3ODQDQG'HWDLOV ķ ķ 60RGXODU5RRI3ODQDQG)UDPLQJ3ODQ'HWDLOV ķ ķ 0HFKDQLFDO3OXPELQJ 00HFKDQLFDO/HJHQGV1RWHV ķ ķ 00HFKDQLFDO3ODQV ķ ķ 00HFKDQLFDO'LDJUDPV ķ ķ (OHFWULFDO ((OHFWULFDO/HJHQGV1RWHV ķ ķ ((OHFWULFDO3ODQV ķ ķ )LUH3URWHFWLRQ )3 2SWLRQDO )LUH6SULQNOHU6\VWHP ķ  Project Address 2429 W Hood Ave Unit #2, Santa Ana, CA 92704 Applicant & Contractor Abodu, Inc. Billy Shondy billy@abodu.com 323 286 7122 Owner Kathy Brown Site Information Lot Size: 8092 SQ FT Existing Structure Size: Main Home at 1014 SQ FT Proposed Structure Size: Proposed ADU at 500 SQ FT Existing Lot Coverage: 13% Proposed Lot Coverage: 19% Zoning: R-1 ADU does not have eaves or projections. ADU is ALL-ELECTRIC. No gas work is included as part of scope. Existing slope is relatively flat. The ADU sf / SFD sf ratio is for Park & Rec fee purpose only. The applicant is responsible for the given SFR of the existing primary residence; Building Safety staff are not responsible for the accuracy of the given SFR. --- ADU Size: 495 SQ FT --- Existing SFD Size: 1014 SQ FT --- Ratio: 0.19 Fire Sprinklers not included. Main home does not contain fire sprinklers. Flood Zone: X Mechanical, electrical and plumbing are not part of this plan review and approval. MEP are subject to building field inspection. General G.001 General Information G.001.1 Site, Landscape, and Grading Plan G.001.2 Display Board G.001.3 Drainage Plan G.010 T24 Energy Analysis CZ8 Architectural A.100 Foundation Plan A.101 Floor and Roof Plan A.200 Exterior Elevations A.300 Sections A.500 Exterior Details A.601 Schedules A.602 1-Hr Fire-Rated Detail A.SW.100 4x4 Decks A.SW.112 Deck Piers Structural S-1.1 Structural Title Sheet S-1.2 Structural Specifications S-2.1 Foundation Plan and Details S-2.2 Modular Roof Plan and Framing Plan Details Electrical E1.1 Electrical Legends, Notes E2.1 Electrical Plans Mechanical/Plumbing M1.1 Mechanical Legends, Notes M2.1 Mechanical Plans M3.1 Mechanical Diagrams The scope is for a 500 sq. ft. detached all-electric Accessory Dwelling Unit (ADU) that is HCD (California Department of Housing and Community Development) approved and inspected as a part of the Factory-Built Housing ADU program. The ADU is to be fully completed in Factory and installed on a Concrete t-footing foundation and connected to site utilities. Main home will not be altered as part of this scope of work. Scope of Work , 1-story Bldg# 101116409 Issued 12/12/23 APPROVALS: PLNG - FArias BLDG - JLo POLICE - BMartin 2429 W Hood Ave #2 - 10111640912/12/2023 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org GRADING PERMIT REQUIREMENTS FOR DETACHED ADU PROJECTS PCC-15 REV: 09/03/2020 Page 1 of 1 A grading permit is required for all new detached buildings including new detached Accessory Dwelling Unit (ADU) projects. Grading plans prepared and stamped by a registered professional engineer shall be submitted for approval prior to issuance of the building permit, and shall be required to be submitted before or concurrently with the architectural plans submittal to the Building Safety Division. Grading Permit Exemption: Residential detached Accessory Dwelling Unit (ADU) projects that meet all of the following may be exempted from grading permit requirements: 1. The maximum amount of soil being moved is less than 50 cubic yards. The soil quantities shall be calculated by a California registered professional civil engineer 2. A site drainage plan prepared by a California registered professional civil engineer shall be provided with the following minimum information, but not limited to: a. Plan(s) shall be stamped, signed and dated by a California registered civil engineer b. Location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks c. Drainage slopes and flow patterns d. Drainage system such as swales, french drains, water collection and disposal system, etc. e. Drainage plan shall indicate how the site grading or drainage system will manage all surface water flows to be diverted away from buildings and adjoining property lines, in accordance with all applicable codes f. The grade shall fall not fewer than 6 inches within the first 10 feet from the foundation wall. Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains, or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet of the building foundation shall be sloped not less than 2 percent away from the building. 3. A final certification letter from the professional engineer of record stating that the grades were constructed per the approved site drainage plan, shall be submitted to the building inspector prior to final inspection 4. The “Detached ADU Grading Permit Exemption Checklist” shall be completed by the California registered professional civil engineer and shall be made a part of the building plans. 5. The site drainage plan and the completed checklist shall be required at the time of architectural plans submittal as part of the building plans package. The building official reserves the right to require a grading plan based on site conditions. This grading permit exemption does not apply to projects in the FEMA Flood Zone. 2429 W Hood Ave #2 - 10111640912/12/2023 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org DETACHED ADU - GRADING PERMIT EXEMPTION CHECKLIST PCC-16 REV: 11/10/2020 Page 1 of 1 THIS FORM SHALL BE COMPLETED BY A CALIFORNIA REGISTERED CIVIL ENGINEER. Instructions: In order to qualify for the grading permit exemption for detached Accessory Dwelling Unit (ADU) projects per handout PCC-15, the registered civil engineer of record shall complete all sections, check all boxes and sign the certification section below. A copy of this checklist shall be attached to each of TWO sets of plans. If answering NO to any of the questions, a grading plan and permit shall be required. Project Address: Yes No 1. ☐ ☐ I have verified that the project address is NOT located on a FEMA designated flood zone (Zone A or AE). 2. ☐ ☐ I have provided two sets of site drainage plans that is stamped, signed and dated by a California professional civil engineer, to be submitted with the building submittal package. 3. ☐ ☐ I have calculated the total amount of soil being cut or filled on this project is less than 50 cubic yards. 4. ☐ ☐ The site drainage plans include the following, but not limited to, location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks; drainage slopes and flow patterns, drainage systems such as swales, french drains, water collection and disposal systems, etc. 5. ☐ ☐ I have designed drainage such that surface water flows away from buildings and adjoining property lines, in accordance with all applicable codes. 6. ☐ ☐ I have designed grading such that it will not adversely affect the adjoining properties. 7. ☐ ☐ I have designed the grade to fall not fewer than 6 inches within the first 10 feet from the foundation walls except where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, I have designed drains or swales to ensure drainage away from the buildings. Any impervious surfaces within 10 feet of the building foundation are sloped not less than 2 percent away from the building. 8. ☐ ☐ I will provide a final certification letter stating that the grades were constructed per the approved site drainage plan, and will submit this certification letter to the building inspector prior to final inspection. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Licensed Number: Date: Phone Number: Email Address: 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 MOD Roof Framing Layout Job No.:Ashley Vance& E N N E EG I NI GR NI C., RFI/SKS: Date: 001 MM.DD.YY 1 1 2 2 3 34 4 A A BB BEDROOM BATHROOM KITCHEN LIVING ROOM MODULAR ROOF FRAMING PLAN RB 1 RB 2 Abodu One 2429 W. Hood Ave. Santa Ana, CALIFORNIA 201601 Page 1.1 of 1.52429 W Hood Ave #2 - 10111640912/12/2023 Ashley&Vance E N G I N E E R I N G , I N C Job:201601 - Abodu One Modular - Abodu Beam/Joist Input Data Description:D LR L S SDS =1.400 1r = 1 ft of roof trib Roof 15 20 0 40 psf ΩO =2.5 2f = 2 ft of floor trib Floor 15 0 40 0 psf 3g = 3 ft of garage trib Garage 0 0 0 0 psf 4d = 4 ft of deck trib Deck 0 0 0 0 psf 5w = 5 ft of wall trib Wall 10 0 0 0 psf ROOF BEAMS adVanceBeam 2.0 Trib LR L S (ft) L/Xa(ft) Lu/Xb(ft)(plf) (plf) (plf) (plf)............RB 1 7.0 r 105 140 0 280 0.0 f 0 0 0 0 Force Loc(ft)%Max 0.0 g 0 0 0 0 Bending 8.4kft 20.5 62% 0.0 d 0 0 0 0 Shear -3,523#20.500001 48% 0.0 w 0 0 0 0 Spans Loc(ft)M(k*ft)Rmin Rmax 1 11.5 1.0 105 140 0 280 Simple Span Roller 1 0 ---312# 1,955# 2 9.0 1.0 105 140 0 280 Simple Span Roller 2 12 --- 591# 4,168# 3 15.5 1.0 105 140 0 280 Simple Span Roller 3 21 0 941# 5,944# Roller 4 36 0 403# 2,488# Additional Loads DEFLECTIONS l / x Defl(in)Loc(ft)%Max --- 0.61 28.77 --- L 360 794 0.23 28.77 45% E|W|S 360 416 0.45 28.77 87% D+L 240 472 0.39 28.77 51%...........RB 2 3.0 r 45 60 0 120 0.0 f 0 0 0 0 Force Loc(ft)%Max 0.0 g 0 0 0 0 Bending -1.8kft 4.5 26% 0.0 d 0 0 0 0 Shear -788#0 22% 1.0 w 10 0 0 0 Spans Loc(ft)M(k*ft)Rmin Rmax 1 9.0 1.0 55 60 0 120 Simple Span Roller 1 0 --- Roller 2 9 --- 149# 788# Additional Loads DEFLECTIONS l / x Defl(in)Loc(ft)%Max --- 0.10 4.5 --- L 360 3049 0.04 4.5 12% E|W|S 360 1525 0.07 4.5 24% D+L 240 1591 0.07 4.5 15%........... SPAN INFO Span/Load Type BEAM DESIGN (2)-1 3/4" x 9 1/2" LVL (1)-1 3/4" x 9 1/2" LVL REACTIONS Max(ASD) Skip Loading Considered REACTIONS Max(ASD) Page 1.2 of 1.52429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 Foundation Layout Job No.:Ashley Vance& E N N E EG I NI GR NI C., RFI/SKS: Date: 001 MM.DD.YY 1 1 2 2 3 34 4 A A BB F 1 P 1 Abodu One California 201601 Page 3.1 of 3.32429 W Hood Ave #2 - 10111640912/12/2023 Ashley&Vance E N G I N E E R I N G , I N C Job:201601 - Abodu Modular - Abodu Footing Width Calculation F1 Description DL LL of Variables:5r = 5 ft of roof trib Roof 0 40 psf 4f = 4 ft of floor trib Floor 0 0 psf 3g = 3 ft of garage trib Garage 0 0 psf 2d = 2 ft of deck trib Deck 0 0 psf w = wall above and/or self wt.Wall 0 0 psf Conventional Footing Design Parameters: Allowable Bearing Pressure 1500 psf FT TRIB Wdl Wll (ft) (plf)(plf) F1 7.5 r 0 300 7.0 f 0 0 0.0 g 0 0 0.0 d 0 0 10.0 w 0 0 TL 0 300 tot 300 plf Try Footing Width, w = 15 inches qbear 240 psf qallow 1500 psf qallow/qbear 6.25 Footing OK t o t q al l w Page 3.2 of 3.32429 W Hood Ave #2 - 10111640912/12/2023 Ashley&Vance E N G I N E E R I N G , I N C P1 Job:201601 - Abodu One Modular - Abodu Point Load on Footing Calculation Reactions on Footing D L E W Pt Load from FB 2 1.0 2.3 --kips Total 1.0 2.3 0.0 0.0 kips U =5.0 kips Required Strength:ASD:P =3.4 kips U = 1.2D + 1.6L P = D + L U = 1.2D + 1.6L + 0.5W P = D + 0.6W P = D + 0.75[L+0.6W] U = 1.2D + 1.6W + 0.5L P = D + 0.7E P = D + 0.75[L+0.7E] U = 1.2D + 1.0E + 1.0L Conventional Footing Design Parameters: Allowable Bearing Pressure 1500 psf Seismic or Wind Loading?N --->1500 psf Calculated Bearing Pressure Footing Width 15 inches Areq 2.2 ft2 Lreq 1.8 ft Model Foundation as Fixed/Fixed Member Eqn. 1: Mu = PL/8 Mu =1.1 k-ft Steel Reinforcing Design: Steel Depth 15 in Bar size (#)4 bar # of bars 1 øMn = 13.1 kip-ft (Design Cap.) Mu=1.1 kip-ft (From Eqn. 1) øMn/Mu =11.8 OK Therefore use 15 inch x 18 inch footing, with (1) #4 bar top and bottom. See Details. Ptot L M r M rr q al l w P Page 3.3 of 3.32429 W Hood Ave #2 - 10111640912/12/2023 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area to Total Resulting Stories: Area Added in Past 2 Years Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has (PR400-402) Fire Sprinkler   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed (PR400-402) Fire Sprinkler   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 LAWN DRIVEWAY LAWN WALL LINE ROOF LINE WALL LINE ROOF LINE WALL LINE ROOF LINE WA L L L I N E RO O F L I N E WA L L L I N E RO O F L I N E WALL LINE ROOF LINE SHED 1 BUILDING LAWN SI D E W A L K PR O P E R T Y L I N E EX I S T I N G F E N C E EX I S T I N G F E N C E PR O P E R T Y L I N E FRONT PROPERTY LINE EXISTING FENCE REAR PROPERTY LINE EXISTING FENCE 53'-6" 20'- 4 " 10 5 ' - 7 " 67' 11 8 ' - 7 " W H O O D A V E N U E S S U L L I V A N S T R E E T 50'-5"8'-10" 7'-8" 35 ' - 1 1 " 55 ' - 8 " 27 ' SITE PLAN SUMMARY: FIRE WALLS: 3, Rear, Right and Left Wall 150' FARTHEST CORNER TO CURB? NO, corner exceeds 150' to curb (156') DEMO: NONE TREES: REMOVE bushes PLANNING ADVISES THAT A BOUNDARY SURVEY BE CONDUCTED EARLY IN THE PROCESS TO VERIFY ACTUAL DISTANCES TO THE MAIN HOME AND PROPERTY LINES. AC ABODU ONE 1BDRM 495 SQ. FT. 14'-9" 5' 16'-5" 38 ' - 1 " EJECTOR PUMP TO BE INSTALLED WHERE GRAVITY CANNOT BE ACHIEVED WATER CONNECTION ELECTRICAL CONNECTION UPGRADING PANEL TO 200 AMP SEWER CONNECTION (E) CLEANOUT FI R E - R A T E D W A L L FI R E - R A T E D W A L L FIRE-RATED WALL TOTAL LOT AREA BUILDING FOOTPRINT = 1,155.33 SQ.FT APPROX. = 7,899.34 SQ.FT SHED 1 = 57.01 SQ.FT APPROX. SHED 2 = 71.27 SQ.FT APPROX. SCALE BAR 18":1'0" 0 5 10 20151 2 3 4 N Address: Parcel ID:Owner:Drawn by: Date: Address: Parcel ID:Owner:Drawn by: Date: Address: Parcel ID:Owner:Drawn by: Date: CHRISTIAN SANTACANA407-111-36 VJL 02-21-2023 2429 W HOOD AVE, SANTA ANA, ORANGE, CA 92704 1/8" : 1'0 SITE PLAN - 1 LANDSCAPING NOTES No NEW landscaping is included as part of this scope of work. Existing landscaping within property as marked and limited to lawn grass and short trees. Image of rear yard provided to the right for reference. Project Information Lot Size: 8092 SQ FT Existing Structure Size: Main Home at 1014 SQ FT Proposed Structure Size: Proposed ADU at 500 SQ FT Existing Lot Coverage: 13% Proposed Lot Coverage: 19% Zoning: R-1 ADU does not have eaves or projections. ADU is ALL-ELECTRIC. No gas work is included as part of scope. Existing slope is relatively flat. Project Address 2429 W Hood Ave, Santa Ana, CA 92704 Applicant & Contractor Abodu, Inc. Billy Shondy billy@abodu.com 323 286 7122 Owner Kathy Brown G.001.1 Site, Landscape, and Grading Plan Fire Hydrant Short Grass Rose Bushes Small Banana Tree Short Grass Existing 5' PUE Easement. ADU would be located outside of easement. Utility Trenching Paths Proposed path of travel from Sullivan Street. Homeowner would construct fence (under 7 feet tall) under a separate scope of work, with an access door located approximately here. Proposed secondary path of travel to ADU. Bushes FROM 100 AMP Stairs & Landing (Refer to Sheet A.SW.100 & A.SW.112) GRADING Light blue arrows represent drainage arrows and routing. Minimal grading would be provided to collect storm-water runoff on site and divert water away from foundation and adjacent properties. Surface water would sheet flow from roof onto drainage routes. No gutters and downspouts are included. Minimal excavation is required to construct the foundation. Please refer to Detail 1 in Sheet S-2.1 (Foundation Details) for more information. Foundation would be a perimeter foundation with a crawl space. 2429 W Hood Ave #2 - 10111640912/12/2023 Real life model of our Abodu One model. This unit is factory-built and approved by State HCD. Diagonal gable roof in black composite shingle. Horizontal lap siding in Artic White. Rendering of proposed detached ADU G.001.2 Display Board 2429 W Hood Ave #2 - 10111640912/12/2023 PUBLIC WORKS AGENCY REERENCESREISIONS ℄ Δ G.001.3 Drainage Plan 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023 OK. Structural calculations updated with revised details to match details in this sheet. See new version of, "8. Structural Calculations" in Project Dox. 2429 W Hood Ave #2 - 10111640912/12/2023 2429 W Hood Ave #2 - 10111640912/12/2023