HomeMy WebLinkAbout2505 W St Andrew Pl - 101113436 & 20178397 - PlanPV-1REV: A1 12/24/2022 FLORES, RALPH ANTHONY 2505 WEST SAINT ANDREW PLACE SANTA ANA, CA 92704 APN # 40808107 TEL #: (714) 925-5990 CLIENT: COVER SHEET CSLB # 619149 CLASS: B, C-10 NAME: GARY GIETZ, JACK MCCLARY SIGNED: 12/24/2022 PHONE 310.904.6139 ENERGY SERVICE PARTNERS 970 W 190TH ST, STE 302 TORRANCE, CA 90502 CONTRACTOR: VICINITY MAPVICINITY MAP AERIAL MAP NOTES SCOPE OF WORK INSTALLATION OF GRID-TIED SOLAR PHOTOVOLTAIC SYSTEM 17 APTOS SOLAR TECHNOLOGY 440 W DNA-144-MF26-440W SOLAR MODULES 1 SOLAREDGE TECHNOLOGIES 6000 W SE6000H-US (240V) HD WAVE INVERTER 17 SOLAREDGE TECHNOLOGIES 440 W S440 OPTIMIZER SYSTEM NAMEPLATE POWER 7.480 KW DC SYSTEM CEC POWER 6.803 KW CEC-AC CONSTRUCTION TYPE V-B OCCUPANCY TYPE R-3 SHEET INDEX 1 COVER SHEET 2 SIGNAGE 3 SITE/ROOF PLAN 3.1 STRING MAP 4 STRUCTURAL 5 ELECTRICAL 6 ELECTRICAL CALCS · ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: ·2019 CBC / 2018 IBC ·2019 CRC / 2018 IRC ·2019 CEC / 2017 NEC ·2019 CMC / 2018 UMC ·2019 CPC / 2018 UPC ·2019 CFC / 2018 IFC ·2019 CA ENERGY CODE ·2019 GREEN CODE 1. ALL WORK TO COMPLY WITH CEC ARTICLE 690 2. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM 3. REMOVAL OF A UTILITY-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR 4. ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY 5. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT AT 25° C; WIRE SHALL BE WET RATED AT 90°C 6. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV TYPE WIRE. 7. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS (CEC 314.15) 8. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS (CEC 250.90, 250.96) 9. FOR UNGROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS SHALL BE PROVIDED WITH A GROUND-FAULT PROTECTION DEVICE OR SYSTEM THAT DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED, AND AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS 10. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT (CEC 250.64C) 11. ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE 12. ALL FIELD-INSTALLED JUNCTION, PULL, AND OUTLET BOXES SHALL BE LOCATED IN A READILY ACCESSIBLE LOCATION DIRECTLY OR BY DISPLACEMENT OF A MODULE SECURED BY REMOVABLE FASTENERS 13. FOR GROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION 14. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKERS SHALL NOT READ "LINE AND LOAD" 15. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT OF LESS THAN 4 PSF 16. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 45 LBS 17. AC DISCONNECT IS A "KNIFE BLADE" TYPE DISCONNECT 18. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH CEC 110.26 19. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT 20. SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED ONTO THE EXISTING DWELLING AS PER THE 2019 CRC. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME; OTHERWISE, THE ALARMS MUST BE HARD WIRED AND INTERCONNECTED. (CRC R314, R315) 21. SMOKE AND CARBON MONOXIDE ALARMS ARE REQUIRED PER CRC SECTIONS R314 AND 315 TO BE VERIFIED AND INSPECTED BY THE INSPECTOR IN THE FIELD. 22. WHEN APPLYING THE 120% RULE OF CEC 705.12(B) , THE SOLAR BREAKER TO BE POSITIONED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER PER 705.12(B) 23. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY SOLAR MODULES - NO BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED OR OBSTRUCTED BLDG #101113436 ISS. 1/12/2023 ELEC #20178397 ISS. 1/12/2023 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 RAIL TO RAIL BONDING #6 BARE COPPER WIRE INV (IF USED) MSP CONTINUOUS GROUND PER SLD JBOX GROUND BUSHINGS REQ. MODULE RAIL SOLAR METER (IF REQ) (A) (1) BOND STRIP GROUNDS RAIL TO RAIL SPLICES - STAR WASHERS USED TO BOND RAIL TO BONDING STRIP (2) SPLICE BAR, SELF-TAP SCREWS JOIN RAILS. BONDING STRIPS USED ON RAILS WITH GROUND LUGS. (1) (2) (3) IF SPLICE BAR HAS INTEGRATED GROUND, BONDING STRIP IS NOT NECESSARY. (3) WHERE NEITHER BONDING STRIP, INTEGRATED GROUNDING SPLICE BAR, OR INTEGRATED GROUNDING MIDCLAMP ARE USED, UL 2703 APPROVED GROUND LUG WITH #6 BARE COPPER SHALL BE USED TO GROUND SPLICED RAILS. USE METHOD (2) (1) (C)RAIL SPLICE GROUNDING (C) #6 BARE COPPER RAIL 1 RAIL 2 EITHER METHOD 1-3 PER MANUFACTURERS INSTALL INSTRUCTIONS CONDUIT COMPRESSION FITTING LOCK NUT GROUNDING BUSHING WITH LAY-IN LUG ENCLOSURE CONTINUOUS GROUND STRIP INSULATION CONDUIT GROUNDING DETAIL EQUIPMENT GROUND BUSHINGS REQ. FOR SYSTEMS OVER 250V A GROUNDING MID CLAMP EACH GROUNDING MID CLAMP PIERCES THROUGH THE ANODIZED COATINGS OF BOTH THE MODULE FRAME AND THE MOUNTING RAIL TO FORM SECURE ELECTRICAL BONDS, WHICH ARE REPEATED THROUGHOUT THE ARRAY AND AT LEAST TWICE PER PANEL. MODULE SHALL BE GROUNDED AT LEAST TWICE OVER WITH A MINIMUM OF TWO MIDCLAMPS. -EVEREST GROUNDING MID CLAMP WITH SERRATED TEETH MIDCLAMP TEETH MODULE PENETRATION MAX. UTILIZATION OF RAIL WITH 1/4" SPACING SERRATED T-BOLT BONDS CLAMP TO RAIL 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 Expedited Permit Process for PV Systems1 Expedited Permit Process for PV Systems Standard String System The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Standard String System to use with the Expe- dited Permit Process. The Micro-Inverter, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 2505 W St Andrew Pl01/13/23 Expedited Permit Process for PV Systems2 Expedited Permit Process for Small-Scale PV Systems Standard String System The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft 2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 2505 W St Andrew Pl01/13/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 3 Standard String System Site Plan                                                          Energy Service Partners 970 W 190th Street FLORES RECIDENCE Torrance, CA 90502 2505 W SAINT ANDREW PLACE, SANTA ANA, CA 92704 permits@joinesp.com 6.803KW-CEC AC 2505 W St Andrew Pl01/13/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Standard String System Electrical Diagram                                                                                                                                                                                                                                                  Energy Service Partners 970 W 190th Street FLORES RECIDENCE Torrance, CA 90502 2505 W SAINT ANDREW PLACE, SANTA ANA, CA 92704 permits@joinesp.com 6.803KW-CEC AC 2505 W St Andrew Pl01/13/23 Ex p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Notes for Standard String System Electrical Diagram Contractor Name, Address and Phone: _________________ _________________ _________________ _________________ Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: __________________________ Site Address: ________________________ System AC Size: ______________________ SIZE FSCM NO DWG NO REV SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS A V V A A W V MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING V W V A A INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ______oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE _____oC 2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1 oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE ® REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) RATED MPP CURRENT RATED MPP VOLTAGE MAX SYSTEM VOLTAGE MAX CIRCUIT CURRENT A V V A PHOTOVOLTAIC POWER SOURCE WARNING: ELECTRICAL SHOCK HAZARD–LINE AND LOAD MAY BE ENERGIZED IN OPEN POSITION AC OUTPUT CURRENT NOMINAL AC VOLTAGE A V SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Energy Service Partners 970 W 190th Street FLORES RECIDENCE Torrance, CA 90502 2505 W SAINT ANDREW PLACE, SANTA ANA, CA 92704 permits@joinesp.com 6.803KW-CEC AC 2505 W St Andrew Pl01/13/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org ESP Contracting (B/C-10) 619149 x x x x x x x x x x Juan M Sanchez (424) 358 3768 permits@joinesp.com 2505 W St Andrew Pl 01/09/23 2505 W St Andrew Pl01/13/23 SOLAREDGE S440 OPTIMIZER J-BOX NEMA3R A B +- DC DC +- DC DC INTEGRATED DC DISCONNECT & AFCI AC DC SOLAREDGE TECHNOLOGIES SE6000H-US (240V) HD WAVE INVERTER STRING 1: (9) APTOS SOLAR TECHNOLOGY (DNA-144-MF26-440W) 440 WATT SOLAR MODULES PAIRED WITH (9) S440 OPTIMIZERS IN (1) SERIES STRING STRING 2: (8) APTOS SOLAR TECHNOLOGY (DNA-144-MF26-440W) 440 WATT SOLAR MODULES PAIRED WITH (8) S440 OPTIMIZERS IN (1) SERIES STRING SOLAREDGE S440 OPTIMIZER (N) LOCKABLE BLADE TYPE NON-FUSIBLE AC DISCONNECT NEMA 3R C EXISTING 200A MAIN BREAKER (CENTER FED) EXISTING 200A MAIN PANEL 40A PV BREAKER INSTALLED AT OPPOSITE END OF BUSBAR FROM MAIN BREAKER 40A-2P 200A M (E)GROUND 120/240 VAC SINGLE PHASE SERVICE (OVERHEAD) 60A-2P 120/240VAC PV-5REV: A1 12/24/2022 FLORES, RALPH ANTHONY 2505 WEST SAINT ANDREW PLACE SANTA ANA, CA 92704 APN # 40808107 TEL #: (714) 925-5990 CLIENT: ELECTRICAL CSLB # 619149 CLASS: B, C-10 NAME: GARY GIETZ, JACK MCCLARY SIGNED: 12/24/2022 PHONE 310.904.6139 ENERGY SERVICE PARTNERS 970 W 190TH ST, STE 302 TORRANCE, CA 90502 CONTRACTOR: ELECTRICAL ∆ TAG CONDUCTOR CONDUCTOR SIZE NUMBER OF CONDUCTORS CONDUIT/CABLE TYPE CONDUIT SIZE A PV-WIRE 10 AWG 4 FREE AIR N/A EGC/GEC: BARE COPPER 6 AWG 1 B THHN/THWN-2 10 AWG 4 EMT 3/4" EGC/GEC: THHN/THWN-2 8 AWG 1 C LINE:THHN/THWN-2 8 AWG 2 EMT 3/4"NEUTRAL: THHN/THWN-2 8 AWG 1 EGC/GEC: THHN/THWN-2 8 AWG 1 EVEREST INTEGRATED GROUNDING & LAY-IN LUGS ARE UL2703 LISTEDGROUNDING DETAIL scale: NTS RAILS MODULES EVEREST RAIL PV MODULE FRAME EVEREST GROUNDING PIERCES THROUGH ANODIZED COATINGS OF MODULE FRAMES AND RAILS EVEREST UNIVERSAL FASTENING OBJECT LAY-IN LUG TERMINAL AL/CU DUAL RATED (TIN PLATED CU) SS SET SCREW INCLUDED EVEREST RAIL #10-24 SS LOCK NUT 6 AWG BARE CU WIRE TE#10-24 X 3/4" SS HCS BOLT #10 SS EXTERNAL TOOTH LOCK (STAR) WASHER SOLAREDGE NOTES: 1. STRING OPERATING VOLTAGE IS CONTROLLED BY INVERTER AND MAINTAINED AT NOMINAL 380 VDC. 2. STRING VOLTAGE IS LIMITED BY INVERTER TO A MAXIMUM OF 480VDC 3. SOLAREDGE DC/DC OPTIMIZERS ARE ALL RUN IN SERIES PER STRING (FIXED SOURCE CIRCUIT VOLTAGE - DC/DC CONVERTERS) 4. STRING CURRENT IS CONTROLLED BY OPTIMIZERS AND IS LIMITED TO 15ADC MAX (PER STRING). 5. INTEGRATED SOLAREDGE DC SWITCH DISCONNECTS BOTH POSITIVE AND NEGATIVE CONDUCTORS AS REQUIRED. 6. SOLAREDGE INVERTERS ARE ALL RAPID SHUTDOWN READY PER CEC 690.12 7. SOLAREDGE INVERTER IS SMART INVERTER COMPLIANT PER CALIFORNIA RULE 21. 8. SOLAREDGE INVERTERS ARE UL1699B CERTIFIED, PROVIDING CEC 2019 690.11 COMPLIANCE SYSTEM NOTES: 1. PV SYSTEM IS UNGROUNDED 2. MODULES ARE BONDED TO RAIL USING EVEREST GROUNDING. 3. RAILS ARE BONDED USING UL 2703 RATED LAY-IN LUGS 4. BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIA IRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC 250.64(C) ALL TERMINALS ARE 75° CELSIUS RATED SOLAR PV CIRCUIT BREAKER MAIN SERVICE BUS RATING PER CEC 705.12(B)(2)(3)(d) 200A x 120% = 240A TOTAL BUS LOAD = (25A x 1.25) + 200A TOTAL SYSTEM TOTAL NUMBER OF MODULES 17 TOTAL NUMBER OF OPTIMIZERS 17 2505 W St Andrew Pl01/13/23 PV-6REV: A1 12/24/2022 FLORES, RALPH ANTHONY 2505 WEST SAINT ANDREW PLACE SANTA ANA, CA 92704 APN # 40808107 TEL #: (714) 925-5990 CLIENT: CALCS CSLB # 619149 CLASS: B, C-10 NAME: GARY GIETZ, JACK MCCLARY SIGNED: 12/24/2022 PHONE 310.904.6139 ENERGY SERVICE PARTNERS 970 W 190TH ST, STE 302 TORRANCE, CA 90502 CONTRACTOR: ELECTRICAL CALCULATIONS INVERTER CHARACTERISTICS - SOLAREDGE SE6000H-US MAX OUTPUT POWER 6000 W SYSTEM OPERATING VOLTAGE 380 V MAX CONTINOUS OUTPUT CURRENT 25 A MAX INPUT VOLTAGE 480 V SYSTEM SHORT CIRCUIT CURRENT 30 A CEC MAX EFFICIENCY 99 % DC DISCONNECT VALUES RATED MAX POWER-POINT CURRENT (IMP) 19.68 A RATED MAX POWER-POINT VOLTAGE (VMP)380 V MAX SYSTEM VOLTAGE (VOC)480.00 V MAX SHORT CIRCUIT CURRENT (ISC)30 A SYSTEM CHARACTERISTICS CALCULATIONS VMP Inverter Fixed String Voltage 380 V 380 V VOC Max Inverter System Voltage 480 V 480 V IMP (DC System Size)/ VMP 7480 W / 380 V 19.68 A ISC (Optimizer Max Output Current) x (# Strings)15 A x 2 30 A AC WIRE SIZING CALCULATIONS AFTER INVERTER Wire = 8 AWG, 55 A @ 90⁰C MAX AC OUTPUT CURRENT (Max Inverter Output) x (Continuous Load)[690.8(B)(1)]25 A X 1.25 31.25 A TOTAL AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table 310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.82 X 55 A X 1 45.10 A 31.25 A ---> 45.10 A Therefore 8 AWG OK MAX AC OUTPUT CURRENT (Max Inverter Output) x (Continuous Load)[690.8(B)(1)]25 A X 1.25 31.25 A 31.25 ---> 40 A Overcurrent Protection TEMPERATURE ADDERS CONDUIT TO BE INSTALLED MIN. OF 7 8" ABOVE ROOF HIGH TEMPERATURE 47 °C LOW TEMPERATURE -2 °C TEMP ADDER FOR ROOF RUN 0 °C TEMP ADDER FOR ATTIC RUN 7 °C DC WIRE SIZING CALCULATIONS AT ARRAY Max Optimizer Current = 15 A, Wire = 10 AWG, 40 A @ 90⁰C 125% MAX CURRENT (Max Optimizer Current) x (Continuous Load)[690.8(A)]15 A X 1.25 18.75 A Per 690.8(B)(1) 40 A > 18.75 A DERATED AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table 310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.82 X 40 A X 1 32.80 A Per. 690.8(B)(2) 32.80 A > 18.75 A 10 AWG PV WIRE OK DC WIRE SIZING CALCULATIONS AT JBOX Max Optimizer Current = 15 A, Wire = 10 AWG, 40 A @ 90⁰C 125% MAX CURRENT (Max Optimizer Current) x (Continuous Load)[690.8(A)]15 A X 1.25 18.75 A Per 690.8(B)(1) 40 A > 18.75 A DERATED AMPACITY (High Temp)[Table 310(B)(2)(A) x (Conductor Ampacity)[Table 310.15(B)(16)] x (Conduit Fill)[Table 310.15(B)(3)(a)]0.82 X 40 A X 0.80 26.24 A Per. 690.8(B)(2) 26.24 A > 18.75 A 10 AWG PV WIRE OK OPTIMIZER CHARACTERISTICS - S440 RATED INPUT DC POWER 440 W MAX INPUT VOLTAGE 60 V MAX INPUT CURRENT 14.5 A MAX OUTPUT VOLTAGE 60 V MAX OUTPUT CURRENT 15 A SAFETY OUTPUT VOLTAGE/OPTIMIZER 1 V MIN/MAX STRING LENGTH 8 / 25 MAX POWER PER STRING [HD-WAVE] 5700 W MODULE CHARACTERISTICS - APTOS DNA-144-MF26-440W [BLK] MAX POWER (PMAX) @ STC 440 W OPEN CIRCUIT VOLTAGE (VOC)49.9 V SHORT CIRCUIT CURRENT (ISC)11.33 A MAX POWER VOLTAGE (VMP)41.0 V MAX POWER CURRENT (IMP)10.74 A SERIES FUSE RATING 20 A 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 2505 W St Andrew Pl01/13/23 December 29, 2022 To Whom it May Concern, I, Ralph Anthony Flores, homeowner of 2505 West Saint Andrew Place, Santa Ana, California 92704, authorize Energy Service Partners DBA ESP Contracting to install solar panels and pull the necessary permits needed to complete my solar project. Sincerely, Ralph Anthony Flores (714) 925-5990 2505 West Saint Andrew Place, Santa Ana, California 92704 Doc ID: 25ce38eba9b115d5b23b9f95feb15ae882632312 2505 W St Andrew Pl01/13/23 Permit Authorization Ralph Anthony Flo...Authorization.pdf 25ce38eba9b115d5b23b9f95feb15ae882632312 MM / DD / YYYY Signed 12 / 30 / 2022 02:21:26 UTC Sent for signature to Ralph Anthony Flores (ralph.flores94@yahoo.com) from contract@joinesp.com IP: 174.205.97.166 12 / 30 / 2022 05:32:00 UTC Viewed by Ralph Anthony Flores (ralph.flores94@yahoo.com) IP: 166.137.163.9 12 / 30 / 2022 05:32:53 UTC Signed by Ralph Anthony Flores (ralph.flores94@yahoo.com) IP: 166.137.163.9 The document has been completed.12 / 30 / 2022 05:32:53 UTC 2505 W St Andrew Pl01/13/23 PV-2REV: A1 12/24/2022 FLORES, RALPH ANTHONY 2505 WEST SAINT ANDREW PLACE SANTA ANA, CA 92704 APN # 40808107 TEL #: (714) 925-5990 CLIENT: SIGNAGE CSLB # 619149 CLASS: B, C-10 NAME: GARY GIETZ, JACK MCCLARY SIGNED: 12/24/2022 PHONE 310.904.6139 ENERGY SERVICE PARTNERS 970 W 190TH ST, STE 302 TORRANCE, CA 90502 CONTRACTOR: WEATHER RESISTANT PLASTIC PLACARD PLACEMENT: MAIN PANEL (COVER) POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS AS SHOWN CAUTION: SIGNAGE LABEL LOCATION: INVERTER, JUNCTION BOXES (ROOF), AC DISCONNECT (PER CODE: CEC690.13 & CEC 690.13) WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED CAUTION: SOLAR CIRCUIT WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM ! WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT WARNING: PHOTOVOLTAIC POWER SOURCE WARNING ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION ! ! AC SYSTEM DISCONNECT FOR UTILITY OPERATION LABEL LOCATION: UTILITY DISCONNECT LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: CEC 705.12(B)(3-4)) LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC/AC CONDUIT, RACEWAYS, ENCLOSURES, AND CABLE ASSEMBLIES AT LEAST EVERY 1O FT, AT TURNS AND ABOVE/BELOW PENETRATIONS AND ALL COMBINER/JUCTION BOXES. LABEL LOCATION: PER CEC 705.12(B)(2)(3)(B) [OR (C) IF PANELBOARD IS RATED NOT LESS THAN SUM OF AMPERE RATINGS OF ALL OVERCURRENT DEVICES SUPPLYING IT] LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE ADHESIVE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.15, 690.13(B)) LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC 690.13(B)) [To be used when inverter is ungrounded] LABEL LOCATION: AC DISCONNECT, POINT OF INTERCONNECTION (PER CODE: CEC 690.53) PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN LABEL LOCATION: WEATHER RESISTANT MATERIAL, DURABLE PLAQUE, UL969 AS STANDARD TO WEATHER RATING (UL LISTING OF MARKINGS NOT REQUIRED), MIN 3 8" LETTER HEIGHT ARIAL OR SIMILAR FONT NON-BOLD, PLACED WITHIN THE MAIN SERVICE DISCONNECT, PLACED ON THE OUTSIDE OF THE COVER WHEN DISCONNECT IS OPERABLE WITH SERVICE PANEL CLOSED. (PER CODE: CEC690.12, 690.56(C)) INVERTER LABEL LOCATION: DC DISCONNECT, INVERTER (PER CODE: CEC690.53) LABEL LOCATION: RAPID SHUTDOWN OR ON INVERTER IF RSD IS INTEGRATED CEC 690.56(C)(3) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 2505 WEST SAINT ANDREW PLACE SANTA ANA, CA 92704 LABEL LOCATION: AC DISCONNECT, INVERTER, POINT OF INTERCONNECTION (PER CODE: CEC 690.54) MAXIMUM SYSTEM VOLTAGE (VOC) MAXIMUM CIRCUIT CURRENT (ISC) MAX RATED OUTPUT CURRENT OF THE CHARGE CONTROLLER OR DC-TO-DC CONVERTER 480 30 15 SIGNAGE REQUIREMENTS: · RED BACKGROUND · WHITE LETTERING · MINIMUM 3/8" LETTER HEIGHT · ALL CAPITAL LETTERS · ARIAL OR SIMILAR FONT, NON-BOLD · REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) ADHESIVE FASTENED SIGNS: · THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. · WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [CEC 110.21(B) FIELD MARKING]. · ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT 25 AMPS AC NOMINAL OPERATING VOLTAGE 240 VOLTS ! LABEL LOCATION: SERVICE DISCONNECTING MEANS (PER CODE: CEC 690.56(C)(1)(A)) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS AC DISCONNECT+ INVERTER SOLAR ARRAY MAIN PANEL 2505 W St Andrew Pl01/13/23 26'-11" PV-3REV: A1 FLORES, RALPH ANTHONY 2505 WEST SAINT ANDREW PLACE SANTA ANA, CA 92704 APN # 40808107 TEL #: (714) 925-5990 CLIENT: SITE PLAN CSLB # 619149 CLASS: B, C-10 NAME: GARY GIETZ, JACK MCCLARY SIGNED: 12/24/2022 PHONE 310.904.6139 ENERGY SERVICE PARTNERS 970 W 190TH ST, STE 302 TORRANCE, CA 90502 CONTRACTOR: ROOF PITCH (DEG) AZIMUTH (DEG) PV AREA (SQ. FT) NO. OF MODS ARRAY 1 13⁰ 270⁰141 6 ARRAY 2 13⁰ 270⁰47 2 ARRAY 3 13⁰90⁰70 3 ARRAY 4 13⁰90⁰23 1 ARRAY 5 13⁰0⁰117 5 CONDUIT NOTES CONDUIT TO BE RUN ON CONDUIT BLOCKS MIN. 1" ABOVE ROOF SURFACE AND UNDER EAVES; AND CLOSE TO RIDGELINES, LABELED AT MAX. 10' INTERVALS. CONDUIT TO BE PAINTED TO MATCH EXTERIOR/EXISTING BACKGROUND COLOR OF ITS LOCATION SITE PLAN scale: 1/16" = 1'-0" CLIENT: DOOR AC DISCONNECT+INVERTER MAIN SERVICE PANEL EQUIPMENT DETAIL SCALE: NTS 12/24/2022 NOTE: · WIRES UNDER PV SHALL NOT HANG OR TOUCH THE ROOF PER CEC 110.12 MODULE APTOS DNA-144-MF26-440W [BLK] MODULE DIMENSIONS 82.48" X 40.91" X 1.57" MODULE WEIGHT 53.13 LBS TOTAL ARRAY AREA 398 SQ. FT. TOTAL ROOF AREA 2270 SQ. FT ROOF TYPE 1 LAYER COMP SHINGLE NO. OF STORIES 1 ROOF COVERAGE 17.5 % SPRINKLER SYSTEM INSTALLED (CFC 903.3.1.3) NO WEST-WALL NORTH-WALL (N)ARRAY 1 (N)ARRAY 2 (N)ARRAY 3 (N)ARRAY 4 (N)ARRAY 5 (E)RESIDENCE W ST ANDREW PL DRIVEWAY (E)FENCE + GATE PROPERTY LINE (E)CHIMNEY (N)J BOX (N)AC DISCONNECT+ (N)INVERTER (N)CONDUIT RUN (E)MAIN PANEL AND SERVICE ENTRANCE FIRE PATHWAY 18'' 18'' 3' 18''18'' 3' 3' 18'' 18'' 3' 28'-10" 25'-11" 5'-9" 7'-4" 3' This item has been digitally signed and sealed on Dec 29, 2022 2505 W St Andrew Pl01/13/23 PV-3.1REV: A1 12/24/2022 FLORES, RALPH ANTHONY 2505 WEST SAINT ANDREW PLACE SANTA ANA, CA 92704 APN # 40808107 TEL #: (714) 925-5990 CLIENT: STRING MAP CSLB # 619149 CLASS: B, C-10 NAME: GARY GIETZ, JACK MCCLARY SIGNED: 12/24/2022 PHONE 310.904.6139 ENERGY SERVICE PARTNERS 970 W 190TH ST, STE 302 TORRANCE, CA 90502 CONTRACTOR: STRING MAP scale: 1/8" = 1'-0" STRING MAP INVERTER SE6000H-US 1 - STRING 1 2 - STRING 2 1 1 1 1 1 1 1 1 2 1 2 2 2 2 2 2 2 2505 W St Andrew Pl01/13/23 PV-4REV: A1 12/24/2022 FLORES, RALPH ANTHONY 2505 WEST SAINT ANDREW PLACE SANTA ANA, CA 92704 APN # 40808107 TEL #: (714) 925-5990 CLIENT: ROOF PLAN CSLB # 619149 CLASS: B, C-10 NAME: GARY GIETZ, JACK MCCLARY SIGNED: 12/24/2022 PHONE 310.904.6139 ENERGY SERVICE PARTNERS 970 W 190TH ST, STE 302 TORRANCE, CA 90502 CONTRACTOR: ROOF PLAN scale: 1/8" = 1'-0" ROOF FRAMING SECTION scale: NTS ROOF PITCH (DEG) AZIMUTH (DEG) PV AREA (SQ. FT) NO. OF MODS ROOF TYPE ROOF ATTACHMENT ROOF HEIGHT EXPOSURE MATERIAL CONSTRUCTION RAFTER SIZE RAFTER SPAN RAIL ATTACHMENT SPACING MAX CANTILEVER LENGTH ARRAY 1 13⁰ 270⁰ 141 6 1 LAYER COMP SHINGLE K2 FLASH COMP KIT 1 - STORY ATTIC WOOD RAFTER 2X6 14' - 0"48" OC 1' - 4" ARRAY 2 13⁰ 270⁰ 47 2 1 LAYER COMP SHINGLE K2 FLASH COMP KIT 1 - STORY ATTIC WOOD RAFTER 2X6 14' - 0"48" OC 1' - 4" ARRAY 3 13⁰ 90⁰70 3 1 LAYER COMP SHINGLE K2 FLASH COMP KIT 1 - STORY ATTIC WOOD RAFTER 2X6 14' - 0"48" OC 1' - 4" ARRAY 4 13⁰ 90⁰23 1 1 LAYER COMP SHINGLE K2 FLASH COMP KIT 1 - STORY ATTIC WOOD RAFTER 2X6 14' - 0"48" OC 1' - 4" ARRAY 5 13⁰ 0⁰117 5 1 LAYER COMP SHINGLE K2 FLASH COMP KIT 1 - STORY ATTIC WOOD RAFTER 2X6 14' - 0"48" OC 1' - 4" BILL OF MATERIAL OBJECTS COUNT END CLAMPS 28 MID CLAMPS 20 RAILS (166")10 RAIL SPLICES 02 FOOTINGS 51 #ROWS OF MODULES 07 MODULES 17 MODULE CLAMP ATTACHMENT MODULE EVEREST CROSSRAIL 44-x K2 FLASH COMP KIT 5/16" X 3-1/2" SS LAG SCREW MINIMUM 2-1/2" EMBEDMENTSTRUCTURAL ATTACHMENT @ MAX 48" OC ALUMINUM L-FOOT 5" TYPICAL ELEVATION DETAIL scale: NTS MODULE APTOS DNA-144-MF26-440W [BLK] MODULE DIMENSIONS 82.48" X 40.91" X 1.57" MODULE WEIGHT 53.13 LBS TOTAL ARRAY AREA 398 SQ. FT. TOTAL ROOF AREA 2270 SQ. FT. ROOF TYPE 1 LAYER COMP SHINGLE MAX DISTRIBUTED LOAD 3 PSF SNOW LOAD 0 PSF WIND SPEED 110 MPH, 3 SEC GUST WIND EXPOSURE C MODULE STRUCTURAL ATTACHMENT 2X6 RAFTER @ 24"OC 1'-6" EAVE OVERHANG (N)ARRAY 1 (N)ARRAY 2 (N)ARRAY 3 (N)ARRAY 4(N)ARRAY 5 CROSSRAIL 44-X K2 FLASH COMP KIT This item has been digitally signed and sealed on Dec 29, 2022 2505 W St Andrew Pl01/13/23