HomeMy WebLinkAbout2621 S Glenarbor St - PlanCODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS CODE INFORMATION APPLICABLE CODES, LAWS AND REGULATIONS 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA FIRE CODE (CFC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA PLUMBING CODE (CPC) 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 1 3 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M (N) GRID TIED PHOTOVOLTAIC SYSTEM SOLAR INDIVIDUAL PERMIT PACKAGE DWI ATMOJO 2621 S GLENARBOR ST 7147248023 SANTA ANA, CALIFORNIA 92704 10.40 kW AHJ: SANTA ANA CITY UTILITY: SOUTHERN CALIFORNIA EDISON CO (N) 13 kWh SUNVAULT ENERGY STORAGE SYSTEM SATELLITE IMAGE CO V E R S H E E T PROJECT LOCATION SHEET INDEX SCOPE OF WORK - (N) 10.400 kW PHOTOVOLTAIC SYSTEM & (N) 13 kWh ENERGY STORAGE SYSTEM - (26) WAAREE ENERGIES LIMITED WSMDi-400 PV MODULES AND (26) ENPHASE IQ7HS-66-M-US MICROINVERTER - POINT OF INTERCONNECTION AT MAIN SERVICE PANEL WITH CIRCUIT BREAKER - MAIN PANEL UPGRADE TO (N) 225A/200A - QUAD/TWIN BREAKERS REQUIRED NOTES ARCHITECTURAL DRAWINGS ELECTRICAL DRAWINGS PVE-1 ELECTRICAL SINGLE-LINE DIAGRAM & PVE-2 ELECTRICAL CALCULATION PVE-3 ELECTRICAL DATA & SPECIFICATIONS SPECIFICATIONS PVE-4 PVE-5 BRANCH DIAGRAM STRUCTURAL DRAWINGS PVS-1 STRUCTURAL INFORMATION & PVA-0 COVER SHEET PVA-1 ARRAY LAYOUT EQUINOX GROUNDING DETAILS PV MOUNTING DETAILS PVE-6 BREAKER SCHEDULE PVS-2 ESS MOUNTING DETAILS NTS SHEET PVA-0 AC SYSTEM SIZE: 9.41 kW DC SYSTEM SIZE: 10.40 kW SEALED FOR ATTACHMENTS AND EXISTING FRAMING ONLY exp: 06/25 Steven Procter Digitally signed by Steven Procter Date: 2023.10.17 13:07:54 -05'00' Bldg# 101118296 Elec# 20182134 APPROVALS: ELEC - MSmith The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 2621 S Glenarbor St - 201821343/6/2024 S G L E N A R B O R S T ROOF 1 RO O F 2 36 " 36 " 18 " 18" M A B HUB+ESS ROOF ACCESS POINT (E) GARAGE (E) FENCE/GATE (E) POOL (N) HUB+ LOCATION (EXT WALL MOUNTED) (N) ESS LOCATION (EXT WALL MOUNTED) ROOF ACCESS POINT 52 ' - 6 " 47'-6" (E) FENCE/GATE 36 " S G R E E N V I L L E S T (E) POOL 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 13 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M AR R A Y L A Y O U T 3/32" = 1'-0" L E G E N D JUNCTION BOX PROPERTY LINE CONDUIT FIRE ACCESS PATHWAY L E G E N D NOTE: 1.FIELD ADJUSTMENTS OF FEWER THAN 6” MAY BE ALLOWED BASED ON SITE CONDITIONS AND MEASUREMENTS. N MODULE: MICROINVERTER: QTY: QTY: ROOF TYPE:NO. OF STORIES: TOTAL ATTACHMENT COUNT: TOTAL ROOF AREA: TOTAL % OF ROOF COVERED BY SOLAR: TOTAL ARRAY AREA: COMP SHINGLE 2 - STORY 66 2541 sq.ft. 22% 570 sq.ft. WAAREE ENERGIES LIMITED WSMDI-400 ENPHASE IQ7HS-66-M-US [240] 26 26 M UTILITY METER AND MAIN SERVICE PANEL SHEET PVA-1 1 2ROOF AZIMUTH PITCH MODULE QTY. 5:12 90° 10 5:12 180° 16 QTY:SUNVAULT™ ENERGY STORAGE SYSTEM (ESS): BASE HUB+NEW HUB+ ESS NEW SUNVAULT ENERGY STORAGE SYSTEM 1SV-BASE13-C ROOF AREA (ft2)631 799 SEALED FOR ATTACHMENTS AND EXISTING FRAMING ONLY exp: 06/25 Steven Procter Digitally signed by Steven Procter Date: 2023.10.17 13:07:26 -05'00' 2621 S Glenarbor St - 201821343/6/2024 TABLE 2: PENETRATION GUIDE FOR INSTALL STACKED STAGGERED FULLY STAGGERED STACKED/STAGGEREDFULLY STAGGERED *CHECK TABLE 1 FOR MAX. PENETRATION SPACING AND PENETRATION PATTERN FOR EACH ARRAY. TWO OR MORE ROWS OF MODULES ONE ROW OF MODULES MID CLAMP FLASHLOC BASE INVISIMOUNT RAIL 0.75" MIN. (E) RAFTER 5/16" X 4" LG. S.S. LAG BOLT WITH 5/16" WASHER @ CENTER TYP. PRE-DRILL REQUIRED. 2- 1 / 2 " M I N . PV MODULE COMPOSITION SHINGLES INVISIMOUNT ROOF ATTACHMENT DETAILS HARDWARE: FLASHLOC COMP PV MODULE EM B E D . TABLE 1 – ARRAYS INFORMATION ROOF PITCH ROOFING TYPE ATTACHMENT TYPE NO. OF STORIES FRAMING TYPE (in.) MAX. RAFTER SPAN (ft.) PENETRATION PATTERN (in.) MAX. ATTACHMENT SPACING (in.) MAX. RAIL OVERHANG (in.) ROOF 1A 22°Comp Shingle Unirac FlashLoc 2 2x6 Rafter @ 24" OC 13.67'Fully Staggered 48"16" ROOF 1B 22°Comp Shingle Unirac FlashLoc 2 2x6 Rafter @ 24" OC 13.67'Fully Staggered 48"16" ROOF 2 22°Comp Shingle Unirac FlashLoc 2 2x6 Rafter @ 24" OC 10'Staggered 48"16" -------------------- -------------------- -------------------- INVISIMOUNT RAIL PV MODULE 5"MA X 2"MI N EXTERNAL LOAD BEARING WALL V A U L T E D INVISIMOUNT RAIL PV MODULE 5"MA X 2"MI N EXTERNAL LOAD BEARING WALL INTERNAL LOAD BEARING WALL INVISIMOUNT RAIL PV MODULE 5"MA X 2"MI N EXTERNAL LOAD BEARING WALL INTERNAL LOAD BEARING WALL STRUCTURAL FRAMING SIDE DETAIL STRUCTURAL FRAMING SIDE DETAIL STRUCTURAL FRAMING SIDE DETAIL ROOF 1A ROOF 1B ROOF 2 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 1 3 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M ST R U C T U R A L I N F O R M A T I O N AN D M O U N T I N G D E T A I L S NTS SHEET PVS-1 SEALED FOR ATTACHMENTS AND EXISTING FRAMING ONLY exp: 06/25 Steven Procter Digitally signed by Steven Procter Date: 2023.10.17 13:08:02 -05'00' 2621 S Glenarbor St - 201821343/6/2024 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 13 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M ST R U C T U R A L I N F O R M A T I O N AN D M O U N T I N G D E T A I L S NTS SHEET PVS-2 2621 S Glenarbor St - 201821343/6/2024 NONO NO NONO EGC: Bare CU #6 BRANCH CIRCUIT FROM PV ARRAY TO JUNCTION BOX #12 2 A -- 1 B JUNCTION BOX, NEMA-4 THWN-2 EGC: THWN-2 1 6 B 3 (4)#10 | (2)#8 #10 EMT 3/4" #8 #10 #10 CONDUCTOR / CONDUIT SCHEDULE DESCRIPTION & CONDUCTOR TYPE CONDUCTOR SIZE (AWG) NUMBER OF CONDUCTORS 1 ROOFTOP ARRAY WIRING A DC AC Branch Circuit #1AC DC AC DC AC Branch Circuit #2 Branch Circuit #3 8 AC MODULES 8 AC MODULES 10 AC MODULES TAG H (E) UTILITY BIDIRECTIONAL METER #: 222013-136497 EXISTING GROUND THWN-2 EGC: THWN-2 1 3 EMT 1-1/2" #6 #2/0 MI D ETHERNET CONNECTION TO DSL/CABLE MODEM CA T 5 e PVS6 BACKUP BUS (200A MAX) (N) HUB+ 200A, 120/240 V, NEMA-3R MODEL: GE N E R A T I O N B U S (1 2 5 A M A X ) 10 YES LOCATION: **PVS6 **BREAKERS ARE FIELD INSTALLED. BREAKER RATING MAY VARY FROM 15A OR 20A SV-HUB-01-C C C OUTSIDE MLO GROUNDED (INCLUDE GEC) UNGROUNDEDü INSTALLATION NOTES 1 CHECK BOX FOR WHETHER SYSTEM IS GROUNDED OR UNGROUNDED: FOR UNGROUNDED SYSTEMS: ·DC OCPD DISCONNECT BOTH CONDUCTORS OF EACH SOURCE CIRCUIT. ·UNGROUNDED CONDUCTORS MUST BE IDENTIFIED PER NEC 210.5(C). WHITE FINISHED CONDUCTORS ARE NOT PERMITTED. 2 3 4 5 6 7 8 9 10 DC / DC CONVERTERS NO SOURCE CIRCUIT JUNCTION BOX SUNVAULT ESS SUNVAULT BATTERY INVERTER SOLAR LOAD CENTER PV PRODUCTION METER SEPARATE AC DISCONNECT HEAT DETECTOR YES NO 11 13 BACK UP LOAD CENTER NON-BACK UP LOAD CENTER EV SUPPLY EQUIPMENT NO TAG DESCRIPTION 12 REMOTE POWER OFF SWITCH 14 HUB+ INCOMING SOURCE FEED , 120/240 V, 1 PH, 3 W LOCATION: MANUF: GND TOP FED MCB GND 200A, 2P 200A,2P 225A EXTERIOR WALL ---- (N) MAIN SERVICE PANEL THE DESIGNED INTERCONNECTION MEETS NEC 705.12(B)(3)(3) REQUIREMENTS 1 PV MODULE MICROINVERTER (FIELD-INSTALLED) MISOLAR / BRANCH 1.PROPER LISTING EXPECTED FOR CONDITIONS OF USE ON ALL LUGS, FITTINGS, CRIMPS, ETC. 2.ALL CONDUIT BEND RADII TO CONFORM TO THE NEC MINIMUM BEND RADII REQUIREMENTS. 3.MINIMUM CLEARANCE SHALL BE MAINTAINED PER NEC FOR ALL NEW EQUIPMENT TO BE INSTALLED. 4.EXISTING GROUNDING ELECTRODE SYSTEM MUST MEET NEC AND LOCAL UTILITY REQUIREMENTS. 5.COPPER CONDUCTORS SHALL BE USED UNLESS SPECIFIED. 6.TYPE NM (ROMEX) CONDUCTORS ARE ALLOWED FOR INTERNAL AND ATTIC RUNS AND SHALL BE INSTALLED MEETING NEC REQUIREMENTS. 7.IF MAIN SERVICE PANEL IS TO BE UPGRADED, IT WILL BE PERMITTED AND INSTALLED BY 3RD PARTY. 8.AC WIRING SHALL UPSIZE IF VOLTAGE DROP EXCEEDS 2%. 9.RUN CONDUCTORS IN EXISTING CONDUIT WHEN AVAILABLE PROVIDED IT HAS NO OTHER CONDUCTORS RUNNING THROUGH IT. 10.EQUIVALENT SPECIFICATION ON CABLES AND ELECTRICAL EQUIPMENT SPECIFIED ARE ACCEPTABLE. ELECTRICAL NOTES SUNPOWER PROVIDED MICROINVERTER EXTENSION CABLE, LISTED AS AN ASSEMBLY MAKE/MODEL: ENPHASE IQ7HS-66-M-US [240] | QTY: 26 MAKE/MODEL: WAAREE ENERGIES LIMITED WSMDI-400 | QTY: 26 NO 20A, 2P 20A, 2P 20A, 2P ENERGY STORAGE SYSTEM MODEL: 6 YES YES 6.5 kWh BATTERY 6.5 kWh BATTERY 5 13 kWh, 6.8 kW SUNVAULT (3) #8 THWN (1) #10 THWN EGC (3) #12 COMM. CABLES INVERTER DC AC LOCKABLE INTEGRATED AC DISCONNECT 40A, 2P SV-BASE13-C TO (E)LOADS NO (N) SPD LAND (N) SURGE PROTECTION DEVICE (SPD) CONDUCTORS TO (N) BREAKER NO NO **GRID SENSE IN ESS NO N - B A C K U P B U S (1 2 5 A M A X ) TO (E) LOADS NO 125A, 2P ·RELOCATE ALL BREAKERS FROM (E) MSP TO APPROPRIATE PANELS OF (N) HUB+. ·INSTALL (N) 225A MAIN SERVICE PANEL IN PLACE OF (E) MSP. INSTALL (N) 200A, 2P SUB FEED BREAKER IN THE (N) MSP AND FEED (N) HUB+ WITH THIS BREAKER. ·INSTALL, WIRE, AND FASTEN A 125A BREAKER ON THE NON-BACKUP BUS USING BREQS125 HOLD DOWN KIT. ·THE FACTORY-INSTALLED CTS INSIDE THE HUB+ ARE SUFFICIENT AS ALL LOADS ARE TO BE TRANSFERRED FROM MSP TO HUB+. ·CTs ARE COMPATIBLE WITH THIS INSTALLATION. ·INSTALL (N) HUB+ ON EXTERIOR WALL, BESIDE (E) MSP. ·INSTALL (N) ESS ON EXTERIOR WALL. ·QUAD/TWIN BREAKERS REQUIRED. ·SEE PVE-6 FOR DETAILS. LOAD LABEL BREAKER SIZE RELOCATED LOADS (BACKUP BUS) DISPOSAL DISHWASHER WASHER CONV DRYER FAU YARD PLUG AIR BLOWER KITCHEN CONV UPSTAIRS BATH POOL LIGHTS JACUZZI LIGHTS LIGHTS 20A, 1P 20A, 1P 20A, 1P 20A, 1P 20A, 1P 20A, 1P 20A, 1P 20A, 1P 20A, 1P 20A, 1P 20A, 1P 15A, 1P 20A, 1P 20A, 1P 20A, 1P KITCHEN 20A, 1P LOAD LABEL BREAKER SIZE RELOCATED LOADS (NON-BACKUP BUS) RANGE 50A, 2P POOL PUMP 20A, 2P NOTE: SEPARATE CONDUIT RUN WILL BE UTILIZED FOR THE RELOCATED LOADS W/ CONSIDERATIONS TO AMPACITY ADJUSTMENT FACTORS CONDUIT/CABLE TYPE CONDUIT SIZE NOTE: SEPARATE CONDUIT RUN WILL BE UTILIZED FOR THE RELOCATED LOADS W/ CONSIDERATIONS TO AMPACITY ADJUSTMENT FACTORS 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 13 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M EL E C T R I C A L S I N G L E - L I N E D I A G R A M & S P E C I F I C A T I O N S NTS SHEET PVE-1 2621 S Glenarbor St - 201821343/6/2024 ELECTRICAL CALCULATIONS BRANCH 2 BRANCH 3BRANCH 1 NUMBER OF MODULES VOLTAGE RATED AC OUTPUT CURRENT: IOUT = MINIMUM WIRE AMPACITY: IMAX = IOUT x 1.25 CONDUCTOR DE-RATING MAXIMUM AMBIENT TEMPERATURE TEMPERATURE USED FOR AMPACITY DE-RATING TEMPERATURE DE-RATING COEFFICIENT FILL DE-RATING COEFFICIENT IWIREMIN = IOUT / TEMP_COEFF / FILL_COEFF WIRE SIZE AMPACITY CONDUCTOR SIZE CONDUCTOR SIZE ADJUSTED FOR VOLTAGE DROP OVERCURRENT PROTECTION MINIMUM OCPD = IOUT x 1.25 CALCULATED VOLTAGE DROP ONE WAY CIRCUIT LENGTH ROOF JCT BOX TO SUBPANEL WIRING #10 8 240 V 12.8 A 16.00 A 34 °C 34 °C 0.96 0.8 16.67 A 40 A #10 #10 0.86% 20A, 2P 16.00 A #8 10 240 V 16 A 20.00 A 34 °C 34 °C 0.96 0.8 20.83 A 40 A #10 #8 0.67% 20A, 2P 20.00 A #10 8 240 V 12.8 A 16.00 A 34 °C 34 °C 0.96 0.8 16.67 A 40 A #10 #10 0.86% 20A, 2P 16.00 A 65 FT.65 FT.65 FT. Load Calculation - ALL HUB+ LOADS 220.82(B)(1)General Lighting @ 3VA/sqft 2842 ft^2 8526 VA Small Appliance 2 3000 VA Laundry 1 1500 VA Microwave 0 VA Refrigerator 0 VA Dishwasher/Garbage Disposal 2 3000 VA FAU 1 750 VA Range 1 9600 VA Oven 0 VA Dryer 0 VA Water Heater 0 VA SPA 0 VA Pool 1 3840 VA EV Charging Equipment 0 VA Other 2P circuit 0 VA Total 30216 VA 220.82(C) First 10,000 VA at 100%10000 VA Remainder @ 40%8086.4 VA Net General Load 18086.4 VA Heating and Air Conditioning AC#1 0 VA Heating #1 0 VA AC#2 0 VA Heating #2 0 VA AC#3 0 VA Heating #3 0 VA Total Heating and AC Load 0 VA Net Load 18,086 VA AMPS 75.36 A Minimum Service Required 100 A Load Calculation - NON-BACKUP LOADS 220.82(B)(1)General Lighting @ 3VA/sqft ft^2 0 VA Small Appliance 0 VA Laundry 0 VA Microwave 0 VA Refrigerator 0 VA Dishwasher/Garbage Disposal 0 VA FAU 0 VA Range 1 9600 VA Oven 0 VA Dryer 0 VA Water Heater 0 VA SPA 0 VA Pool 1 3840 VA EV Charging Equipment 0 VA Other 2P circuit 0 VA Total 13440 VA 220.82(C) First 10,000 VA at 100%10000 VA Remainder @ 40%1376 VA Net General Load 11376 VA Heating and Air Conditioning AC#1 0 VA Heating #1 0 VA AC#2 0 VA Heating #2 0 VA AC#3 0 VA Heating #3 0 VA Total Heating and AC Load 0 VA Net Load 11,376 VA AMPS 47.40 A Minimum Service Required 100 A Load Calculation - BACKUP LOADS 220.82(B)(1)General Lighting @ 3VA/sqft 2842 ft^2 8526 VA Small Appliance 2 3000 VA Laundry 1 1500 VA Microwave 0 VA Refrigerator 0 VA Dishwasher/Garbage Disposal 2 3000 VA FAU 1 750 VA Range 0 VA Oven 0 VA Dryer 0 VA Water Heater 0 VA SPA 0 VA Pool 0 VA EV Charging Equipment 0 VA Other 2P circuit 0 VA Total 16776 VA 220.82(C) First 10,000 VA at 100%10000 VA Remainder @ 40%2710.4 VA Net General Load 12710.4 VA Heating and Air Conditioning AC#1 0 VA Heating #1 0 VA AC#2 0 VA Heating #2 0 VA AC#3 0 VA Heating #3 0 VA Total Heating and AC Load 0 VA Net Load 12,710 VA AMPS 52.96 A Minimum Service Required 100 A NOTE: DISTANCE ABOVE ROOF TO BOTTOM OF CONDUIT: >23mm (7/8") 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 13 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M EL E C T R I C A L C A L C U L A T I O N NTS SHEET PVE-2 2621 S Glenarbor St - 201821343/6/2024 · RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN AND REDUCE SHOCK HAZARD IN THE ARRAY SOLAR ELECTRIC PV PANELS SIGNAGE LOCATIONS: ·SHALL BE LOCATED ON OR NO MORE THAN 1 M (3 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. SIGNAGE LOCATIONS: ·MAIN SERVICE PANEL ENERGY STORAGE SYSTEM CONTAINS ENERGIZED BATTERIES SIGNAGE LOCATIONS: ·SUNVAULT ENERGY STORAGE SYSTEM ENERGY STORAGE SYSTEM DISCONNECT SIGNAGE LOCATIONS: ·SUNVAULT ENERGY STORAGE SYSTEM CAUTION TRI POWER SOURCES SECOND SOURCE IS AC BATTERY THIRD SOURCE IS PV SYSTEM SIGNAGE LOCATIONS: ·SUNVAULT ENERGY STORAGE SYSTEM AVAILABLE FAULT CURRENT DERIVED FROM THE ESS: DATE CALCULATION PERFORMED: ENERGY STORAGE SYSTEM DISCONNECT NOMINAL ESS AC VOLTAGE: MAXIMUM ESS DC VOLTAGE: 10-15-2023 35 A 57.6 V 120/240 VAC 60 Hz 1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE, WEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. 2.ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM 3 8" LETTER HEIGHT, WHITE ON RED BACKGROUND. 3.MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED ADJACENT TO MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION WHERE THE LEVER IS OPERATED. 4.MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKINGS SHALL BE PLACED EVERY 10', AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL DC COMBINER AND JUNCTION BOXES. 5.DO NOT USE SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. SIGNAGE NOTES ELECTRICAL DATA & SPECIFICATIONS WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. SIGNAGE LOCATIONS: ·MAIN SERVICE PANEL ·NEW INDOOR / OUTDOOR LOAD CENTER ·INDOOR / OUTDOOR SUBPANEL NEC 705.12(B)(3)(3) DO NOT ADD NEW LOADS SIGNAGE LOCATIONS: ·MAIN SERVICE PANEL NO BRANCH CIRCUIT LOADS LARGER THAN AMPS MAY BE INSTALLED IN THIS SUBPANEL SIGNAGE LOCATIONS: ·HUB+ BACKUP PAN ·BACKUP LOAD CENTERS 35 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 13 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M EL E C T R I C A L D A T A & S P E C I F I C A T I O N S NTS SHEET PVE-3 2621 S Glenarbor St - 201821343/6/2024 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 13 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M MHUB+ESS FIGURE 1: SUNPOWER EQUINOX GROUNDING DETAILS PHOTOVOLTAIC ARRAY ON ROOF SERVICE POINT & UTILITY METERING FIGURE 2: PLACARD IDENTIFYING LOCATION OF DISCONNECTS AND POWER SOURCES PL A C A R D / S U N P O W E R E Q U I N O X GR O U N D I N G D E T A I L S 2621 S GLENARBOR ST HUB+ ENERGY STORAGE SYSTEM 690.47(B) NTS SHEET PVE-4 CAUTION: MULTIPLE SOURCES OF POWER WITH DISCONNECT(S) LOCATED AS SHOWN: 2621 S Glenarbor St - 201821343/6/2024 ROOF 1 RO O F 2 MHUB+ESS 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 13 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M BR A N C H D I A G R A M N PRINT NAME OF CREW LEAD ON SITE: _________________________________ CREW LEAD SIGNATURE: _________________________________ BRANCH VOLTAGES: 1. 2. 3. 4. 5. 6. NTS SHEET PVE-5 HOME OWNER ACKNOWLEDGEMENT (AS-BUILT) SIGNATURE PRINTED NAME 1 2ROOF AZIMUTH PITCH MODULE QTY. 5:12 90° 10 5:12 180° 16 2621 S Glenarbor St - 201821343/6/2024 MAIN SERVICE PANEL 200A, 2P MAIN BREAKER 200A, 2P HUB+ HUB+ Back Up Section 20A, 1P | 20A,1P DISPOSAL | KITCHEN 20A, 1P | 20A,1P WASHER | CONV 20A, 1P | 20A, 1P DISH | KITCHEN 20A, 1P | 20A,1P DRYER | FAU **, 2P PVS 6 20A, 1P | 20A,1P YARD PLUG | AIR BLOWER 20A, 1P | 20A,1P CONV | UPSTAIRS BATH MASTER 40A, 2P ESS Disconnect 15A, 1P | 20A,1P POOL LIGHTS | JACUZZI 20A, 1P | 20A,1P LIGHTS | LIGHTS Solar Section 20A, 2P PV BREAKER 20A, 2P | 20A, 2P PV BREAKER | PV BREAKER Non Back Up Pan **,2P Grid Sense 125A, 2P NBU OCPD 50A, 2P | 20A, 2P RANGE | POOL PUMP **BREAKERS ARE FIELD INSTALLED. BREAKER RATING MAY VARY FROM 15A OR 20A NOTES: QUAD/TWIN BREAKERS REQUIRED. 1 4 1 4 H A R B O U R W A Y S O U T H R I C H M O N D , C A 9 4 8 0 4 ( 5 1 0 ) 5 4 0 - 0 5 5 0 C O R P O R A T I O N , S Y S T E M S R E V I S I O N S SO L A R I N D I V I D U A L P E R M I T P A C K A G E GR I D - T I E D P H O T O V O L T A I C S Y S T E M REV DESCRIPTION DATE DB DRAWN BY: PROJECT DATE DRAWN SCALE DW I A T M O J O 26 2 1 S G L E N A R B O R S T SA N T A A N A , C A L I F O R N I A 9 2 7 0 4 RP-460674 10 . 4 0 k W 10-15-2023 P. Avena PATRICK AVENA C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 C A L I C E N S E C - 1 0 , B # 8 9 0 8 9 5 (N ) 13 k W h S U N V A U L T E N E R G Y S T O R A G E S Y S T E M BR A N C H D I A G R A M NTS SHEET PVE-6 2621 S Glenarbor St - 201821343/6/2024 20 psf 95 mph C 0 psf Exposure Cat: Ground Snow: Code:2022 California Building Code ASCE 7-16 Live Load: Ult Wind Speed: Design Criteria: 10/17/2023 Attn.: To Whom It May Concern re: Job DWI ATMOJO: 2621 S GLENARBOR ST, SANTA ANA, CALIFORNIA 92704 The following calculations are for the structural engineering design of the photovoltaic panels. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. If you have any questions, don't hesitate to contact. 51 Rio Roble, San Jose, CA 95134 | 1-408-240-5500 Steven Procter Digitally signed by Steven Procter Date: 2023.10.17 13:09:39 -05'00' 2621 S Glenarbor St - 201821343/6/2024 Date :10/17/2023 Job Code: DWI ATMOJO 2 of 7 Structure Geometry: Mean Roof Height, hn =23 ft Eave Height, he =18 ft Building Length, L =53 ft Building Width, B =48 ft Module Area =21.6 ft² Roof Properties: Roof Pitch (deg) = Roofing Type = Sheathing Type = Wood Species = Wood Fb (psf) = Wood Fv (psf) = Wood E (psf) = Wood Lag Withdrawal (lb/in) = Framing Type = Framing OC Spacing (in.) = Section Thickness, b (in.) = Section Depth, d (in.) = Section Modulus, Sx (in.^3) = Beam Span (ft) = Pen Trib Width (ft) = Rail Span (ft) = CD (Wind) = CD (Snow) = CLS = CM = Ct = CL = CF = Cfu = Ci = Cr = Mallowable_Wind (lb-ft) = Mallowable_snow (lb-ft) = 1357 1357 975 975 1.0 1.0 1.15 1.15 1.3 1.3 1.0 1.0 1.0 1.0 1.0 1.0 1.00 1.00 1.0 1.0 1.6 1.6 1.15 1.15 4.00 4.00 3.16 3.16 13.67 10 5.50 5.50 7.56 7.56 1.50 1.50 2x6 Rafter 2x6 Rafter 24 24 230400000 230400000 266 266 129600 129600 25920 25920 5/8 OSB Sheathing 5/8 OSB Sheathing Doug Fir-Larch #2 Doug Fir-Larch #2 Comp Shingle Comp Shingle 22 22 Roof 1A/1B Roof 2 51 Rio Roble, San Jose, CA 95134 | 1-408-240-5500 2621 S Glenarbor St - 201821343/6/2024 Date :10/17/2023 Job Code: DWI ATMOJO 3 of 7 Dead Load: 3.0 2.0 0.9 1.0 Total Roof 1A/1B DL 6.9 psf 3.0 2.0 0.9 1.0 Total Roof 2 DL 6.9 psf 2.3 psf Roof_Dist_DL = M_Roof_Dist_DL = Def_Roof_Dist_DL = PV_uni_Dist_DL = M_PV_uni_Dist_DL = Def_PV_uni_Dist_DL = Total_uni_DL = M_Total_uni_DL = Def_Total_uni_DL = Rail_Down_DL = Rail_M_DL = Pens_Down_DL = Pens_Side_DL = Wind Load: Ultimate Wind Speed =95 mph Directionality Factor, kd =0.85 11 11 7 7 27 27 7 7 0.0392 0.0112 20 20 465 249 115 61 0.0097 0.0028 0.0295 0.0084 5 5 15 15 350 187 PV DL Roof 1A/1B Roof 2 2x6 Rafter @ 24" OC Misc (Insulation etc) Comp Shingle 5/8 OSB Sheathing 2x6 Rafter @ 24" OC Misc (Insulation etc) Comp Shingle 5/8 OSB Sheathing 51 Rio Roble, San Jose, CA 95134 | 1-408-240-5500 2621 S Glenarbor St - 201821343/6/2024 Date :10/17/2023 Job Code: DWI ATMOJO 4 of 7 Topographic Factor, kzt =1 Velocity Pressure Exposure Factor, kz =0.93 Ground Elevation Factor, ke =1.00 psf Velocity Pressure, qz =18.24 Solar Equalization Factor, γa =0.60 Array Edge Factor, γE = External Pressure Up, GCp_1 = External Pressure Up, GCp_2 = External Pressure Up, GCp_3 = External Pressure Down, GCp = psf Design Pressure Up, p_1 = psf Design Pressure Up, p_2 = psf Design Pressure Up, p_3 = psf Design Pressure Down, p = uni_Dist_W_up = M_uni_Dist_W_up = Def_uni_Dist_W_up = uni_Dist_W_down = M_uni_Dist_W_down = Def_uni_Dist_W_down = Module_Up_W1 = Module_Up_W2 = Module_Down_W = Rail_Up_W1 = Rail_Up_W2 = Rail_Down_W = Rail_M_Up_W1 = Rail_M_Up_W2 = Rail_M_Down_W = Pens_Up_W1 = Pens_Up_W2 = Pens_Down_W = -456 -456 202 202 56 56 -311 -311 -86 -86 -127 -127 -114 -114 51 51 16 16 -78 -78 -25 -25 -36 -36 747 400 0.0630 0.0180 -0.0969 -0.0278 32 32 -49 -49 -1150 -616 -37.76 -37.76 16.00 16.00 -24.62 -24.62 -36.12 -36.12 -2.30 -2.30 0.60 0.60 -1.50 -1.50 -2.20 -2.20 Roof 1A/1B Roof 2 1.5 1.5 51 Rio Roble, San Jose, CA 95134 | 1-408-240-5500 2621 S Glenarbor St - 201821343/6/2024 Date :10/17/2023 Job Code: DWI ATMOJO 5 of 7 Rail Check (LRFD): Roof 1A/1B 1.4D :10 lb-ft <548 lb-ft OK Roof 1A/1B 1.2D + 1.6S + 0.5W :37 lb-ft <548 lb-ft OK Roof 1A/1B 1.2D + 0.5S + 1.0W :65 lb-ft <548 lb-ft OK Roof 1A/1B 0.9D + 1.0W (Up z1) :80 lb-ft <548 lb-ft OK Roof 1A/1B 0.9D + 1.0W (Up z2) :120 lb-ft <548 lb-ft OK Roof 2 1.4D :10 lb-ft <548 lb-ft OK Roof 2 1.2D + 1.6S + 0.5W :37 lb-ft <548 lb-ft OK Roof 2 1.2D + 0.5S + 1.0W :65 lb-ft <548 lb-ft OK Roof 2 0.9D + 1.0W (Up z1) :80 lb-ft <548 lb-ft OK Roof 2 0.9D + 1.0W (Up z2) :120 lb-ft <548 lb-ft OK Attachment Check (ASD): Roof 1A/1B 1.0D + 0.6W :148 lbs <907 lbs OK Roof 1A/1B 1.0D + 0.75*[1.0S + 0.6W] :118 lbs <907 lbs OK Roof 1A/1B 1.0D + 1.0S :27 lbs <907 lbs OK Roof 1A/1B 0.6D + 0.6W (Up z1) :171 lbs <931 lbs OK Roof 1A/1B 0.6D + 0.6W (Up z2) :258 lbs <931 lbs OK Roof 2 1.0D + 0.6W :148 lbs <907 lbs OK Roof 2 1.0D + 0.75*[1.0S + 0.6W] :118 lbs <907 lbs OK Roof 2 1.0D + 1.0S :27 lbs <907 lbs OK Roof 2 0.6D + 0.6W (Up z1) :171 lbs <931 lbs OK Roof 2 0.6D + 0.6W (Up z2) :258 lbs <931 lbs OK Lag Screw Uplift Check (ASD): Roof 1A/1B Lag Screw Withdrawl Value =266 lbs 5/16 Dia. Roof 1A/1B Lag Screw Penetration =2.5 Roof 1A/1B 0.6D + 0.6W (Up z1) : 171 lbs <665 lbs OK Roof 1A/1B 0.6D + 0.6W (Up z2) : 258 lbs <665 lbs OK Roof 2 Lag Screw Withdrawl Value =266 5/16 Dia. Roof 2 Lag Screw Penetration =2.5 Roof 2 0.6D + 0.6W (Up z1) : 171 lbs <665 lbs OK Roof 2 0.6D + 0.6W (Up z2) : 258 lbs <665 lbs OK 51 Rio Roble, San Jose, CA 95134 | 1-408-240-5500 2621 S Glenarbor St - 201821343/6/2024 Date :10/17/2023 Job Code: DWI ATMOJO 6 of 7 Framing Check (ASD): Roof 1A/1B uni 1.0D + 0.6W :913 lb-ft <1357 lb-ft OK Roof 1A/1B uni 1.0D + 0.75*[1.0S + 0.6W] :801 lb-ft <1357 lb-ft OK Roof 1A/1B uni 1.0D + 1.0S :465 lb-ft <975 lb-ft OK Roof 1A/1B uni 0.6D + 0.6W (Up z1) :411 lb-ft <1357 lb-ft OK Roof 2 uni 1.0D + 0.6W :489 lb-ft <1357 lb-ft OK Roof 2 uni 1.0D + 0.75*[1.0S + 0.6W] :429 lb-ft <1357 lb-ft OK Roof 2 uni 1.0D + 1.0S :249 lb-ft <975 lb-ft OK Roof 2 uni 0.6D + 0.6W (Up z1) :220 lb-ft <1357 lb-ft OK Seismic Check: Stucco 10.0 psf 2x4 Studs @ 16"2.0 psf Gypsum 3.0 psf Misc. (Insulation, etc.)2.0 psf 17 psf 3636 ft^2 61812 lbs 7 psf 2544 ft^2 17669 lbs 44 lbs 26 1155 lbs %increase = (Wexisting + Wadditional) / Wexisting =OK Limits of Scope of Work and Liability 1.45% The increase in weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. Total Roof Area = Total Roof W =Existing Weight PV Panel W = Number of Panels = Total PV W =Additional Weight Total Wall DL = Total Wall Area = Total Wall W =Existing Weight Total Roof DL = 51 Rio Roble, San Jose, CA 95134 | 1-408-240-5500 2621 S Glenarbor St - 201821343/6/2024 Date :10/17/2023 Job Code: DWI ATMOJO 7 of 7 The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. 51 Rio Roble, San Jose, CA 95134 | 1-408-240-5500 2621 S Glenarbor St - 201821343/6/2024 2621 S Glenarbor St - 201821343/6/2024 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 2621 S Glenarbor St - 201821343/6/2024 February 10, 2023 SunPower 77 Rio Robles San Jose, CA 95134 TEL: (408) 514-4063 Attn: Sunpower – Engineering Department Re: Engineering Certification for the SunPower Corporation Invisimount Mounting System Span Tables and Design Methodology PZSE, Inc.-Structural Engineers has reviewed the SunPower Invisimount Mounting System Span Tables Revision F published September 21, 2021 and Revision G published August 25, 2022 and their design methodology. This certification covers the module clamp, rail analysis, and attachment Tile hook/L bracket components. All information, data and analysis contained within are based on, and comply with, the following building codes and typical specifications: Building Codes: 1. Minimum Design Loads for Buildings and other Structures, ASCE/SEI 7-16 2. 2022 California Building Code, by California Building Standard Commission 3. 2022 California Residential Code, by California Building Standard Commission 4. 2021 International Building Code, by International Code Council, Inc 5. 2015 Aluminum Design Manual, by The Aluminum Association 6. CPP Wind Tunnel report number 9790, dated 16 February 2017. 7. SEAOC PV-2, 2017 8. 2018 NDS, by the American Wood Council 9. UL 2703 Testing report for PV solar panels. 10. AC428, Acceptance Criteria for Modular Framing Systems Used to Support Photovoltaic (PV) Panels, November 1, 2012 by ICC-ES Component and Cladding Roof Zones: The Components and Cladding Roof Zones shall be determined based on ASCE 7 Chapter 30, and CPP Wind Tunnel test number 9790, dated 16 February 2017. Notes: 1) Racking system and panels shall be installed per manufacturer’s specifications. 2) Design assumptions are specified in the Inputs pages of attached span tables. 3) Attachment design is based on 5/16” Dia. Lag Screw with 2.5” Embedment into SPF#2 or equivalent per NDS. Designer shall be responsible for verifying project specific site conditions. 4) Wind speeds are LRFD values. 5) Attachment spacing(s) apply to seismic design category E or less. 2621 S Glenarbor St - 201821343/6/2024 Design Responsibility: These tables are intended to be used under the responsible charge of a registered design professional where required by the authority having jurisdiction. In all cases, these tables should be used under the direction of a design professional with sufficient structural engineering knowledge and experience to be able to: • Evaluate whether these tables are applicable to the project, and • Understand and determine the appropriate values for all input parameters of these tables. This letter certifies that the loading criteria and design basis SunPower Invisimount Mounting System Span Tables are in compliance with the Codes above. This certification excludes the capacity check of the building structure to support the loads imposed on the building by the array, such as bending strength of roof rafters spanning between supports. This requires additional knowledge of the building and is outside the scope of the design tool and our review. If you have any questions on the above, do not hesitate to call. Prepared By: PZSE, Inc. - Structural Engineers Roseville, CA REENI IGER LARUTCURTS AINROFILACFOETATS GNELANOISSEFORPDERETSEHCAZHTENEKL N AP Exp. 3-31-25 No. S3878 R U DIGITALLY SIGNED 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 SPAN TABLES, INVISIMOUNT 22 SQ. FT. MODULE WITH COMPOSITE SHINGLE - MOUNTING ROOF ATTACHMENT ASCE 7-16 VERSION Item Number: 524734 8-25-22 Ethan Ely REVISION HISTORY REV. DCR# DESCRIPTION DATE AUTHOR A DCO-008990 • Initial Release 4-10-17 P. Todd B DCO-010454 • Exposure D added. 10-10-17 G. Rossi C DCO-010454 • A-Series Modules Added. • Color coding of Span Tales Added. 6-11-19 E. Ely D DCR-003763 • CA Only • ASCE 7-16 Update 2-20-20 J. Mansell E DCR-003794 • Module Pressure Capacities Increased • Expanded for all States 4-27-20 J. Mansell F DCR-003922 • M-series module added 9-21-21 E. Ely G TBD • Version for Universal InvisiMount system 8-25-22 E. Ely Instructions: 1. Tables in this document have been generated from the Excel tool, item #524735 2. See the Engineering Certification Letter for Professional Engineer stamp. 3. Delete this first page when printing. 4. The Span Tables are split among several volumes due to the various combinations of Modules + Attachments + Applicable Codes. 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 List of Volumes Standard Volumes 1. 22 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-10 2. 22 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-16 3. 22 Sq. Ft. Module + Tile Attachment w/ ASCE 7-10 4. 22 Sq. Ft. Module + Tile Attachment w/ ASCE 7-16 High Loading Volumes 5. High Wind Speeds: 22 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-10 6. High Wind Speeds: 22 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-16 7. High Wind Speeds: 22 Sq. Ft. Module + Tile Attachment w/ ASCE 7-16 8. High Wind Speeds: 20 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-10 9. High Wind Speeds: 20 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-16 10. High Wind Speeds: 20 Sq. Ft. Module + Tile Attachment w/ ASCE 7-16 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 Document #524734 Rev G, Vol. 2 1 SunPower Proprietary InvisiMount Span Tables Engineering Summary Letter Volume: 2 ASCE 7 Version: 7-16 Module Type: 22 Sq. Ft. Module Roof Attachment: Composite Shingle High Wind: No High Snow: No The Span Tables are divided into two Parts: • Part 1: Simplified Tables (Wind Tunnel Loads) • Part 2: General Tables (ASCE 7 Analytical Method) Part 1 features spans based on forces on the InvisiMount system using exposure coefficients, GCp, provided by a Wind Tunnel Test Report by Cermak, Petrka, & Petersen (CPP). These values provide a more accurate and economical solution but apply to less configurations. It is recommended to use these values whenever possible, and when not, to use the spans provided in Part 2. Approved Attachments: The following span tables are adequate for the following roof attachments: • SunPower InvisiMount L-Foot attachment • Pegasus Composite Shingle Roof Attachment o And roof attachments with capacities equal to or greater than all of the following Load and Resistance Factor Design (LRFD) values: ▪ Tension – 1000lb ▪ Compression – 1000lb ▪ Shear – 390lb Scope: • Module orientations: Portrait & Landscape • Gable and Hip roofs only with modules not in the overhang sections of the roof • Roof heights o 30ft (Part 1 only) o 20-60ft (Part 2 only) • Roof Slope o 4:12 to 8:12 (Part 1 only) o 2:12 to 12:12 (Part 2 only) • Exposures Categories B, C, D • Basic Wind Speeds: o ASCE 7-10: 110-140mph – High Wind: 145-180mph o ASCE 7-16: 90-130mph – High Wind: 135-180mph • Ground Snow Loads: o 0-60psf (10psf increments) o High Snow Volumes: 80-200psf (20psf increments) o High Wind Volumes: 0psf 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 Document #524734 Rev G, Vol. 2 2 SunPower Proprietary Module Size and Capacity: • These tables are applicable to modules with the following dimensions: o Maximum length: 6.56 ft. (2.00 m) o Maximum surface area: 22 sq. ft. (2.04 sq. m) o Maximum height: 1.57 in. (40 mm) • These tables do not include a check of the module’s capacity. A module check must be performed by the user in addition to identifying the appropriate span. • In the Part 1 (Wind Tunnel-based) span tables, module pressures are provided adjacent to the corresponding spans. These module pressures are derived from the Wind Tunnel Test Report for each output condition. The user must confirm that the design capacities of the module to be used are greater than both the uplift and downforce pressured identified. • For the Part 2 span tables, pressure on the module must be calculated per the appropriate ASCE code (7-10 or 7-16). • A summary of the equations required to calculate these values is provided in the following section. 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 Document #524734 Rev G, Vol. 2 3 SunPower Proprietary Module Pressure Calculation (ASCE 7-16): • The following equations reflect ASCE-prescribed calculations, with values specific to InvisiMount included where possible. • Note that some conservative assumptions have been made and, in some cases, the resulting values may be more conservative than a site-specific iteration of the ASCE-based calculations. • The below equations are applicable only to modules with an area equal to or greater than 19.5 ft^2. • See below glossary for definitions of all referenced variables. • ASCE 7 §2.3 defines load combination equations for LRFD, which generate design load pressures. The controlling equations which define the design load on the module are: o 𝑷𝒖𝒑=𝟎.𝟗𝑫+𝟏.𝟎𝑾𝒖𝒑 o 𝑷𝒅𝒐𝒘𝒏=𝑴𝒂𝒙{𝟏.𝟐𝑫+𝟏.𝟔𝑺+𝟎.𝟓𝑾𝒅𝒐𝒘𝒏 𝟏.𝟐𝑫+𝟏.𝟎𝑾𝒅𝒐𝒘𝒏+𝟎.𝟓𝑺 • The process for solving for these equations is as follows: o Identify site-specific inputs: ▪ 𝒛 =[ ] 𝑓𝑡 ▪ 𝑬 =[ 𝐵 / 𝐶 / 𝐷 ] ▪ 𝑽 =[ ] 𝑚𝑝ℎ ▪ 𝒑𝒈=[ ] 𝑝𝑠𝑓 ▪ 𝜽 =[ ] 𝑑𝑒𝑔𝑟𝑒𝑒𝑠 ▪ 𝒁𝒐𝒏𝒆=[ 1 / 2 / 3 ] o Select the following coefficients from the below Look-up Tables: ▪ 𝒛𝒈 =[ ] 𝑓𝑡 ▪ 𝑪𝒆 =[ ] ▪ 𝜶 =[ ] ▪ 𝑮𝑪𝒑,−=[ ] ▪ 𝑮𝑪𝒑,+=[ ] o Use the following equations to establish wind and snow loads: ▪ The minimum allowable value for 𝑊𝑢𝑝 & 𝑊𝑑𝑜𝑤𝑛 is 16 psf. ▪ Wind, Uplift: 𝑾𝒖𝒑 =𝟎.𝟎𝟎𝟑𝟏𝟔𝟓(𝒛 𝒛𝒈 ) 𝟐 𝜶∗𝑽𝟐∗𝑮𝑪𝒑,− ▪ Wind, Downforce: 𝑾𝒅𝒐𝒘𝒏=𝟎.𝟎𝟎𝟐𝟑𝟔𝟐∗(𝒛 𝒛𝒈 ) 𝟐 𝜶∗𝑽𝟐∗𝑮𝑪𝒑,+ ▪ Snow: 𝑺 =𝒑𝒔,𝒈𝒓∗𝐜𝐨𝐬(𝜽) If 𝜃≥15°, 𝑝𝑠,𝑔𝑟=0.84 ∗𝐶𝑒∗𝑝𝑔 If 𝜃<15° 𝐴𝑁𝐷 𝑝𝑔<20 𝑝𝑠𝑓, 𝑝𝑠,𝑔𝑟=𝑝𝑔 If 𝜃<15° 𝐴𝑁𝐷 𝑝𝑔>20 𝑝𝑠𝑓, 𝑝𝑠,𝑔𝑟=𝑀𝑎𝑥{20 𝑝𝑠𝑓 0.84 ∗𝐶𝑒∗𝑝𝑔 o Add the resulting load pressures in the load combination equations (dead load is provided): ▪ 𝑷𝒖𝒑=𝟐.𝟓 𝒑𝒔𝒇+𝟏.𝟎𝑾𝒖𝒑 ▪ 𝑷𝒅𝒐𝒘𝒏=𝑴𝒂𝒙{𝟑.𝟓 𝒑𝒔𝒇+𝟏.𝟔𝑺+𝟎.𝟓𝑾𝒅𝒐𝒘𝒏 𝟑.𝟓 𝒑𝒔𝒇+𝟏.𝟎𝑾𝒅𝒐𝒘𝒏+𝟎.𝟓𝑺 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 Document #524734 Rev G, Vol. 2 4 SunPower Proprietary • Look-up Tables o Exposure-based coefficients: Exposure 𝑪𝒆 𝜶 𝒛𝒈 B 0.9 7 1200 C 0.9 9.5 900 D 0.8 11.5 700 o External pressure coefficients: ▪ These values are based on a minimum module size of 19.5 ft^2. ASCE 7-16 Gable Roof Hip Roof 7 < θ <= 20 20 < θ <= 27 27 < θ <= 45 7 < θ <= 20 20 < θ <= 27 Gcp,- Zone 1 -2.000 -1.500 -1.510 -1.800 -1.226 Zone 2 -2.585 -2.179 -1.777 -2.333 -1.777 Zone 3 -3.078 -2.471 -2.200 -2.333 -1.777 Gcp,+ All Zones 0.467 0.467 0.784 0.584 0.584 ASCE 7-16 Hip Roof θ = 30.26 (7:12) θ = 33.69 (8:12) θ = 36.87 (9:12) θ = 39.81 (10:12) θ = 42.51 (11:12) θ = 45 (12:12) Gcp,- Zone 1 -1.062 -1.126 -1.185 -1.239 -1.290 -1.336 Zone 2 -1.265 -1.419 -1.561 -1.693 -1.814 -1.926 Zone 3 -1.413 -1.541 -1.647 -1.735 -1.808 -1.866 Gcp,+ All Zones 0.551 0.551 0.551 0.551 0.551 0.551 • Glossary of variables: o 𝑃𝑢𝑝=𝑚𝑜𝑑𝑢𝑙𝑒 𝑢𝑝𝑙𝑖𝑓𝑡 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 o 𝑃𝑑𝑜𝑤𝑛=𝑚𝑜𝑑𝑢𝑙𝑒 𝑑𝑜𝑤𝑛𝑓𝑜𝑟𝑐𝑒 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 o 𝐷=𝑑𝑒𝑎𝑑 𝑙𝑜𝑎𝑑=2.7 𝑝𝑠𝑓 o 𝑊𝑢𝑝=𝑢𝑝𝑙𝑖𝑓𝑡 𝑤𝑖𝑛𝑑 𝑙𝑜𝑎𝑑 (𝑝𝑠𝑓) o 𝑊𝑑𝑜𝑤𝑛=𝑑𝑜𝑤𝑛𝑓𝑜𝑟𝑐𝑒 𝑤𝑖𝑛𝑑 𝑙𝑜𝑎𝑑 (𝑝𝑠𝑓) o 𝑆=𝑠𝑛𝑜𝑤 𝑙𝑜𝑎𝑑 (𝑝𝑠𝑓) o 𝑧=𝑟𝑜𝑜𝑓 ℎ𝑒𝑖𝑔ℎ𝑡 (𝑓𝑡) o 𝐸=𝑒𝑥𝑝𝑜𝑠𝑢𝑟𝑒 (𝐵,𝐶,𝑜𝑟 𝐷) o 𝑣=𝑤𝑖𝑛𝑑 𝑠𝑝𝑒𝑒𝑑 (𝑚𝑝ℎ) o 𝑝𝑔 =𝑔𝑟𝑜𝑢𝑛𝑑 𝑠𝑛𝑜𝑤 𝑙𝑜𝑎𝑑 (𝑝𝑠𝑓) o 𝜃=𝑟𝑜𝑜𝑓 𝑝𝑖𝑡𝑐ℎ (𝑑𝑒𝑔𝑟𝑒𝑒𝑠) o 𝑍𝑜𝑛𝑒=𝑟𝑜𝑜𝑓 𝑧𝑜𝑛𝑒 (1,2,𝑜𝑟 3) o 𝑧𝑔=𝑔𝑟𝑎𝑑𝑖𝑒𝑛𝑡 ℎ𝑒𝑖𝑔ℎ𝑡 (𝑓𝑡) o 𝛼=𝑔𝑢𝑠𝑡 𝑝𝑟𝑜𝑓𝑖𝑙𝑒 𝑓𝑎𝑐𝑡𝑜𝑟 o 𝐶𝑠=𝑅𝑜𝑜𝑓 𝑠𝑙𝑜𝑝𝑒 𝑓𝑎𝑐𝑡𝑜𝑟 o 𝐶𝑒=𝑒𝑥𝑝𝑜𝑠𝑢𝑟𝑒 𝑓𝑎𝑐𝑡𝑜𝑟 o 𝐺𝐶𝑝,−= 𝑒𝑥𝑡𝑒𝑟𝑛𝑎𝑙 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑐𝑜𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑡,𝑢𝑝𝑙𝑖𝑓𝑡 o 𝐺𝐶𝑝,+= 𝑒𝑥𝑡𝑒𝑟𝑛𝑎𝑙 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑐𝑜𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑡,𝑑𝑜𝑤𝑛𝑓𝑜𝑟𝑐𝑒 o 𝑝𝑠=𝑠𝑙𝑜𝑝𝑒𝑑 𝑟𝑜𝑜𝑓 𝑠𝑛𝑜𝑤 𝑙𝑜𝑎𝑑 o 𝑝𝑠,𝑔𝑟=𝑠𝑛𝑜𝑤 𝑙𝑜𝑎𝑑,𝑖𝑛 𝑑𝑖𝑟𝑒𝑐𝑡𝑖𝑜𝑛 𝑜𝑓 𝑔𝑟𝑎𝑣𝑖𝑡𝑦 2621 S Glenarbor St - 201821343/6/2024 Document #524734 Rev G, Vol. 2 5 SunPower Proprietary Inputs (ASCE 7-16): The following tables list the allowable spacing of attachment points for the SunPower InvisiMount mounting system. The following building codes and standards were used in the calculations: • International Building Code (IBC 2018) • International Residential Code (IRC 2018) • Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) • Aluminum Design Manual (ADM1), 2015 • National Design Specification (NDS) for Wood Construction, 2018 The International Building Code is either adopted fully or mostly by each state. The accompanying Engineering Certification Letter lists the building code for the state which this project. Loads on the system were calculated in accordance with ASCE 7-16, using the following parameters: • Risk Category II • Dead Load: System weight (including PV modules and rails) = 2.7 psf • Roof Live Load: 0psf – No live load acts on top of the PV modules • Roof Snow Load Data: o Ground snow load, pg, as indicated in the tables (Fig. 7-1) o Thermal factor, Ct = 1.2, ‘unheated and open-air structures’ (Table 7.3-2) o Exposure factor, Ce = 0.9, ‘fully exposed’ (Table 7.3-1) o Slope factor, Cs, varies with slope and assumes the array is an ‘unobstructed slippery surface’ where snow is free to slide off the array (Figure 7.4-1) • Wind Design Data (Designed per Chapter 30, Components & Cladding): o With modifications to GCp values per SEAOC PV2-2017 o Basic Design Wind speed, V, and exposure category as indicated in the tables (Figure 26.5-1B) o Roof height and slope as indicated in the tables (§26.2) o Topographic factor, Kzt = 1.0 (Table 26.6-1) o Directionality factor, Kd = 0.85 (Table 26.6-1) o Velocity Coefficient, Kh = 2.01(z/zg)^(2/a) (as indicated in Table 26.10-1) o Velocity Pressure Exposure Coefficient, Ke=1 (Table 26.9.1) o Pressure coefficients, GCp, per either wind tunnel testing or Chapter 30 (see notes below tables) • Earthquake Design Data (Designed per Chapter 13: Non-structural Components) o Seismic Design Category E, Soil Site Class D assumed o Mapped MCE Short Period, 0.2sec, Ss = 3.73g, maximum in the United States (Fig. 22 -1) o Mapped MCE Short Period, 1sec, S1 = 1.39g (Fig. 22-2) o Importance Factor, Ip = 1.0 (§13.1.3) o Amplification Factor, ap=1.0 (Table 13.6-1) o Response Factor, Rp=1.5 (Table 13.6-1) • Load combinations per IBC §1605, using Load and Resistance Factor Design (LRFD) 2621 S Glenarbor St - 201821343/6/2024 Document #524734 Rev G, Vol. 2 6 SunPower Proprietary Methodology: The maximum allowable spans shown in the tables are based on a combination of dead, wind, seismic, and snow loads calculated from the inputs above and combined using LRFD combinations. The maximum forces are then compared to the minimum capacities determined in the following ways: • Rail bending and shear: ADM1 LRFD checks • Rail to roof attachment: SunPower Test Reports of the rail bolt between the rail and the roof attachment. • Roof attachment: Manufacturer product information • Roof attachment to rafter: Lag screw withdrawal and shear per NDS • The reported maximum spacing is the greatest allowed spacing, rounded down to the nearest rafter spacing increment, for which the demand/capacity ratios are less than or equal to 1.0, assuming both 16” and 24” rafter spacings. • These tables do not consider the strength of the supporting roof structure. In areas of low snow load, the weight of the array is often considered to offset the design live load of the roof, since personnel and equipment cannot be placed on top of the array. It is recommended to stagger attachment points, as shown in Figure 1, to evenly distribute loads to the rafters. Figure 1 • These tables assume that each module is installed centered over a pair of rails, as shown in Figure 2(a). In cases where one rail is closer to the midpoint of the module, as shown in Figure 2(b), adjustments to the spacing may be required. Figure 2 2621 S Glenarbor St - 201821343/6/2024 Document #524734 Rev G, Vol. G 29 SunPower Proprietary InvisiMount Span Tables Part 2: General Tables (ASCE 7 Analytical Method) How to Use These Tables • Determine the snow load and roof height for the site and select the corresponding table. • Determine the wind speed and roof slope for the site. The value in the table, for this wind speed and roof slope, is the allowable span between attachment points, in inches. • See figure below for locations of zones 1, 2 and 3. Dimension “a” is 10% of the least horizontal dimension or 0.4h, whichever is smaller, but not less than either 4% of the least horizontal dimension or 3 feet. 2621 S Glenarbor St - 201821343/6/2024 Notes: • Tables are based on strength of the InvisiMount rail and approved roof attachment in the Engineering Summary Letter of this document, in conformance with IBC and referenced standards. • Maximum allowable cantilever is equal to 1/3 of the allowable span. • Wind speeds are ultimate values in mph, as defined in ASCE 7. Wind pressure coefficients are derived from ASCE 7 Chapter 30. • User is responsible for verifying the strength of the roof. • User is responsible for verifying the capacity of the module. Refer to the section of this document titled “Module Pressure Calculation”, or the appropriate ASCE code (7-10 or 7-16), for instructions on calculating the uplift and downforce module pressures. Document #524734 Rev G, Vol. 2 95 SunPower Proprietary Exposure C Ground Snow (psf) 0 Roof Height (ft) 20 INVISIMOUNT ALLOWABLE SPANS - ZONE 1 (IN) Slope → 9.46 ° 14.04 ° 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° 36.87 ° 39.81 ° 42.51 ° 45 ° Speed↓ 2:12 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12 90 96 96 96 96 96 96 96 96 96 96 96 95 96 96 96 96 96 96 96 96 96 96 96 100 96 96 96 96 96 96 96 96 96 96 96 105 80 80 80 96 96 96 96 96 96 96 96 110 80 80 80 96 96 96 96 96 96 96 96 120 72 72 72 80 80 80 80 80 80 80 80 130 72 72 72 80 80 80 80 80 80 80 80 INVISIMOUNT ALLOWABLE SPANS - ZONE 2 (IN) Slope → 9.46 ° 14.04 ° 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° 36.87 ° 39.81 ° 42.51 ° 45 ° Speed↓ 2:12 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12 90 80 80 80 96 96 96 96 96 96 96 96 95 80 80 80 96 96 96 96 96 96 96 96 100 80 80 80 80 80 96 96 96 96 96 96 105 72 72 72 80 80 96 96 96 96 96 96 110 72 72 72 80 80 80 80 80 80 80 80 120 48 48 48 72 72 80 80 80 80 80 72 130 48 48 48 64 64 72 72 72 72 72 64 INVISIMOUNT ALLOWABLE SPANS - ZONE 3 (IN) Slope → 9.46 ° 14.04 ° 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° 36.87 ° 39.81 ° 42.51 ° 45 ° Speed↓ 2:12 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12 90 80 80 80 96 96 96 96 96 96 96 96 95 72 72 72 80 80 96 96 96 96 96 96 100 72 72 72 80 80 80 80 80 80 80 80 105 64 64 64 72 72 80 80 80 80 80 80 110 48 48 48 72 72 80 80 80 80 80 80 120 48 48 48 64 64 72 72 72 72 72 72 130 48 48 48 48 48 64 64 64 48 48 48 2621 S Glenarbor St - 201821343/6/2024 sunpower.com Datasheet SunPower® SunVault™ Energy Storage System (ESS) Performance SunVault Base SunVault Base High Energy Model Number SV-BASE13-C SV-BASE19.5-C DC Rated Energy 13 kWh 19.5 kWh Max. Usable Energy (DC)1 12 kWh 18 kWh Battery Cell Chemistry Lithium iron phosphate (LiFePO4) Nom. Internal Battery Voltage 51.2 V CEC Weighted RTE Efficiency2 > 86% Max. AC Continuous Backup Output Current 28.3 A Max. AC Output Fault Current 35 A AC Overcurrent Protection Device 40 A / two pole Nom. AC Voltage (L–N–L) 120 / 240 VAC 60 Hz, split phase4 Max. Short Circuit Rating 10 kA Max. Single-Phase Load Supported (120 V) 4.8 kW (up to 5 minutes) Power Factor (full-rated power) ± 0.85 Rated Continuous Charge Power (Grid tied & Backup) 6.4 kW Rated Continuous Discharge Power (Grid tied) 6.0 kW Rated AC Continuous Output Current (Grid tied) 25.0 A Rated Backup Discharge Power Continuous 6.8 kW Environmental Seismic Rating IEEE 693-2005, AC-156 Environmental Rating10 Indoor and outdoor rated Acoustic Noise Level < 50 dBA @ 1 m distance, 86°F (30°C) Recommended Operating Temp. 32°F to 86°F (0°C to 30°C) Ambient Operating Temp.6 14°F to 122°F (−10°C to 50°C) Shelf Ambient Temp. −4°F to 113°F (−20°C to 45°C) Initial Energy Reserve 30% Humidity 0–95% (non-condensing) Enclosure Type / Ingress Rating NEMA Type 3R / IP54 Max. Elevation 6560 ft (2000 m) Warranties, Certifications, and Compliance Warranty 10 years Certifications and Compliance • IFCC Part 15 Subclass B • IEEE 1547 • UL 1973 (UL 1642) • UL 1741 • UL 1741 SA (CA Rule 21) • UL 9540 • UL 9540A • UN 38.3 • UL 67 Mechanical User Interface Mobile app, LED panel Dimensions 64.5 h × 28 w × 14 in. d (164 × 71 × 36 cm)7 ESS Disconnecting Means Integrated AC disconnect: • Rotary style • Open air • Lockable in OPEN position Weight • SV-BASE: 259 lb (117.5 kg) • SV-BASE13: 479 lb (217 kg) • SV-BASE19.5: 589 lb (267 kg) Mounting Options Wall or floor8 sunpower.com Datasheet Configurations and Specifications SunVault System Configuration 13-1 19.5-1 26-2 39-2 Included Component Model Numbers⁹ • One Hub+ • One SV-BASE13-C • One Hub+ • One SV-BASE19.5-C • One Hub+ • Two SV-BASE13-C • One Hub+ • Two SV-BASE19.5-C DC Rated Energy 13 kWh 19.5 kWh 26 kWh 39 kWh Max. Usable Energy (DC)1 12 kWh 18 kWh 24 kWh 36 kWh Max. AC Continuous Backup Output Current 28.3 A continuous 56.6 A continuous Max. AC Output Fault Current 35.0 A 70.0 A AC Overcurrent Protection Device One 40 A / two pole Two 40 A / two pole Rated Single-Phase Load Supported (120 V) 4.8 kW (up to 5 minutes) 9.6 kW (up to 5 minutes) Rated Continuous Charge Power (grid tied and backup) 6.4 kW 12.8 kW Rated Continuous Discharge Power (grid tied) 6.0 kW 12.0 kW Rated Continuous Discharge Power (backup) 6.8 kW 13.6 kW Rated AC Continuous Output Current (grid tied) 25.0 A 50.0 A Load Start Capability (LRA) 43 A 52 A 86 A 104 A Rated Backup Discharge Power (kW)5 30 minutes 7.5 8.0 15.0 16.0 10 seconds 8.5 12.0 17.0 24.0 1 second 10.0 12.0 20.0 24.0 1 Some energy reserved for internal consumption. 2 Tested at 6 kW, 25°C conditions. 3 SunVault Hub+ rating is 200 A. 4 208 VAC is not supported at this time. 5 Values are rated at 25°C ambient. 6 Extended exposure reduces battery performance. 7 Two ESS enclosures for 26 kWh and 39 kWh. 8 Additional hardware details in installation guide 9 SV-BASE13-C and SV-BASE19.5-C ship as the same item and are field marked for 13 kWh or 19.5 kWh; a BASE may be converted in the field to a BASE X. 10 SunVault is designed and intended for residential use only. Specifications included in this datasheet are subject to change. Some parameters can vary depending on site-specific conditions. See the SunVault Storage Installation Guide 6503770 for guidelines. See www.sunpower.com/facts for additional reference information. Specifications included in this datasheet are subject to change without notice. © 2023 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, and SUNVAULT are trademarks or registered trademarks of SunPower Corporation in the U.S. and other countries as well. 1-800-SUNPOWER. 536812 RevG BA S E Hu b + Hu b + Hu b + Hu b + BA S E Hi g h E n e r g y BA S E X BA S E BA S E Hi g h E n e r g y BA S E X Hi g h E n e r g y 2621 S Glenarbor St - 201821343/6/2024 sunpower.com Datasheet SunPower® SunVault™ Hub+™ Electrical Model Number SV-HUB-01-B / SV-HUB-01-C Applications Self-supply, backup, and cost savings Special Features PCS, Remote Power Off Supported Backup Configurations •Whole home (up to 200 A service) •Partial home (up to 400 A service) Max. Allowed Service / Disconnect Rating 200 A Nom. Allowed Service Voltage 120 / 240 V 60 Hz, split phase Short Circuit Rating1 10 kA / 22 kA2 Overcurrent Protection Device Allowed3 100–200 A / service entrance rated AC Metering Solar meter: ANSI C12.20, < 0.5% RGM | Site meter: < 2% Connectivity Ethernet, WiFi, and cellular Backup Transition Seamless Load / Generation Breakers4 Refer to installation guide for available spaces Overvoltage Category OV IV Pollution Degree III Protection Class I Scalability5 Supports multiple storage and PV systems in parallel 1 Higher short circuit rating is compatible with external suitable rated equipment. 2 With external J-Class fuse or CSR breaker. See the SunVault Installation Guide for guidelines. 3 Recommended service-rated circuit breaker type must be installed. 4 See the SunVault Installation Guide for guidelines. 5 See the SunVault Installation Guide for guidelines. Refer to www.sunpower.com/facts for additional reference information. For more details, see extended datasheet www.sunpower.com/datasheets. Specifications included in this datasheet are subject to change without notice. ©2022 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, SUNVAULT, and Hub+ are trademarks or registered trademarks of SunPower Corporation in the U.S. and other countries as well. 1-800-SUNPOWER. Environmental Ambient Operating Temp. −4°F to 122°F (−20°C to 50°C) Shelf Ambient Temp. −22°F to 140°F (−30°C to 60°C) Humidity 0–95% (non-condensing) Enclosure Type / Ingress Rating NEMA Type 3R / IP54 Max. Elevation 6560 ft (2000 m) Environment Indoor / Outdoor Mechanical Dimensions 17 w × 46 h × 6 in. d (43 × 117 × 15 cm) Weight 80 lb (36 kg) Mounting Options Indoor / Outdoor Conduit Entry Multiple; up to 3 in. (7.6 cm) Warranties, Certifications, and Compliance Warranty 10 years Certifications and Compliance •ANSI C12.20 (Class 0.5) •CSA C22.2 No. 107.1 •FCC Part 15 Subclass B •UL 67 •UL 869A •UL 1741 •UL 1741 CRD PCS 55 33 66 88 11 33 ReRe vv DD 2621 S Glenarbor St - 201821343/6/2024 996.00±1.00Mounting Hole8Nos-8x12 ARKA SERIES WSMDi-395 to WSMDi-415 ELECTRICAL CHARACTERISTICS +VE TERMINAL 996.00±1.00 400.00±1.00 Mounting Hole 8Nos-8x12 Mounting Hole 4Nos-7x10 Ho l e Dr a i n i n g Better performance under all climatic conditions Split junction box Reduced power losses up to 1/4 times PID resistant with long term reliability Sustain heavy wind & snow loads (2400 pa & 5400 pa) I-V VARIATION WITH IRRADIANCE I-V VARIATION WITH TEMPERATURE The Graphs are for reference purpose only. Please consult Waaree technical team for further clarifications. ISO 9001:2015 l ISO 14001:2015 l ISO 45001:2018 Independent assessment of factories by BLACK & VEATCH 2 M6 Mono PERC cells 166 mm Highest reliability & enhanced crack tolerant 9BB module ARKA SERIES WSMDi-395 to WSMDi-415 Linear Performance Warranty Standard Performance Warranty 1 5 12 27 100% 98.00% 91.95% 83.70% INTERNATIONAL & NATIONAL CERTIFICATIONS^ IEC 61215 | IEC 61730 | UL61730 IEC TS 62804-1 • The electrical data given here is for reference purpose only. • Please confirm your exact requirements with the sales representative while placing your order. • Refer installation Manual instructions & Waaree warranty statement for terms & conditions. • Waaree Reserves the right to change the specifications without prior notice.z Temperature coefficient of Current (Isc), α (%/ºC) Temperature coefficient of Voltage (Voc), ß (%/ºC) Temperature coefficient of Power (Pm), γ (%/ºC) NOCT (ºC) Operating temperature range (ºC) 43 ± 2 -40 to 85 DESIGN SPECIFICATIONS MECHANICAL CHARACTERISTICS Length x Width x Thickness (L x W x T) Weight Solar Cells per Module (Units) / Arrangement Solar Cell Type & Size Front Glass Encapsulate Junction Box (Protection degree/ Material ) Cable & Connector (Protection degree / Type) Cable cross - section & Length 2 Waaree Energies Ltd. is amongst the top Solar Energy Companies and has the country's largest Solar PV Module manufacturing capacity of 5 GW. In addition, it is committed to provide top notch EPC services, project development, rooftop solutions, solar water pumps and also in an Independent Power Producer. Waaree has its presence in over 325+ locations nationally and 68 countries globally. *If you need specific product certificates, and if module installations are to deviate from our guidance specified in our installation manual, please contact your local Waaree sales and technical representatives. 0.055 -0.285 -0.365 12 Years Product Warranty • 27 Years Power Output Warranty Models Pmax (W) STC NOCT Vmp (V) STC NOCT Imp (A) STC NOCT Isc (A) STC NOCT Voc (V) STC NOCT Module Eff. (%) 34.70 34.90 35.10 WSMD-395 WSMD-400 WSMD-405 WSMD-410 WSMD-415 *Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s. Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%. 19.78 20.03 20.28 20.53 20.78 45.00 45.22 45.44 45.66 45.88 42.10 42.30 42.50 42.70 42.90 11.24 11.32 11.40 11.48 11.57 9.08 9.14 9.21 9.27 9.34 10.47 10.54 10.61 10.68 10.75 8.55 8.62 8.68 8.74 8.81 37.77 38.00 38.22 38.44 38.66 35.30 35.40 395 400 405 410 415 296.8 300.6 304.4 308.2 312.1 ARKA SERIES WSMDi-395 to WSMDi-415 ELECTRICAL CHARACTERISTICS System Voltage 1500 V Series Fuse Rating 22 A VE TERMINAL-+VE TERMINAL996.00±1.001360.00±1.00860.00±1.00 400.00±1.00Mounting Hole 8Nos-8x12 Mounting Hole 4Nos-7x10Grounding Hole Ø4mm-2No's Hole Draining THERMAL CHARACTERISTICS Anodized Aluminium Alloy, Anodization thickness ≥15 micron 4 mm & 1200mm 1924 mm (L) x 1038 mm (W) x 35 mm (T) 22 kgs 132 cells / (11x6 || 11x6) Mono PERC, 83 x 166 mm 3.2 mm Low Iron and Tempered glass with ARC coating PID Free & UV Resistant IP68 / Weatherproof PPO IP68 rated / Staubli MC4 Connector WEL/E&PD/395-415/132/MP/HC/CMZ/01/27.07.2022 Frame Fire rating Type 2 2621 S Glenarbor St - 201821343/6/2024 The high-powered smart grid-ready IQ7HS Microinverter with integrated MC4 connectors dramatically simplifies the installation process while achieving the highest system efficiency. The IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. IQ7HS Microinverter To learn more about Enphase offerings, visit enphase.com Data Sheet Enphase Microinverter Region: AMERICAS Easy to Install • Lightweight and simple • Faster installation with improved, lighter two-wire cabling • Built-in rapid shutdown compliant (NEC 2014, 2017 & 2020) Efficient and Reliable • Highest CEC efficiency of 97.0% • More than a million hours of power-on testing • Class II double-insulated enclosure • UL listed Smart Grid-Ready • Complies with advanced grid support, voltage and frequency ride-through requirements • Remotely updates and responds to changing grid-requirements • Configurable for varying grid profiles • Meets CA Rule 21 (UL1741-SA) and IEEE 1547:2018 (UL1741-SB) To learn more about Enphase offerings, visit enphase.com © 2022 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 12-15-2022 INPUT DATA (DC)IQ7HS-66-M-US Commonly used module pairings¹320W - 460W Module compatibility²66 cell/120 half-cell/132 half-cell Maximum input DC voltage 59V Peak power tracking voltage 38V - 43V Operating range 20V - 59V Min/Max start voltage 30V/59V Max DC short circuit current (module Isc)15A Overvoltage class DC port II DC port backfeed current 0A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC)@240 VAC @208 VAC Peak output power 384 VA 369 VA Maximum continuous output power 384 VA 369 VA Nominal (L-L) voltage/range³240V/211-264V 208V/183-229V Maximum continuous output current 1.60A (240V) 1.77A (208V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 Hz to 68 Hz 47 Hz to 68 Hz AC short circuit fault current over 3 cycles 4.82A 4.82 A Maximum units per 20 A (L-L) branch circuit4 10 9 Overvoltage class AC port III III AC port backfeed current 18 mA 18 mA Power factor setting 1.0 1.0 Power factor (adjustable)0.85 leading ...0.85 lagging 0.85 leading ...0.85 lagging EFFICIENCY @240V @208V CEC weighted efficiency 97.0 % 96.5 % MECHANICAL DATA Ambient temperature range Relative humidity range Connector type Dimensions (WxHxD) Weight Cooling Approved for wet locations Pollution degree Enclosure Environmental category/UV exposure rating Altitude -40ºC to +60ºC 4% to 100% (condensing) Staubli made MC4 212 mm x 175 mm x 30.2 mm (without bracket) 1.08 kg (2.38 lbs) Natural convection - No fans Yes PD3 Class II, corrosion resistant polymeric enclosure NEMA type 6/outdoor 2000 m FEATURES Communication Power Line Communication (PLC) Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect means required by NEC 690 and C22.1-2018 Rule 64-220. Compliance CA Rule 21 (UL1741-SA), IEEE 1547:2018 (UL1741-SB), UL 62109-1, FCC Part 15 Class B, HECO v1.1, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL listed as PV Rapid Shutdown Equipment and conforms with NEC 2014, NEC 2017, and NEC 2020 section 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according to manufacturer’s instructions. 1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Provided the module is compatible with all other parameters in the datasheet. 3. Nominal voltage range can be extended beyond nominal if required by the utility. 4. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ7HS Microinverter 2621 S Glenarbor St - 201821343/6/2024 © 2022 Enphase Energy, Inc. enphase.com July 29, 2022 To whom it may concern, This letter confirms and attests that: SPWR-A5 is equivalent to Enphase Models: IQ7HS-66-ACM-US, 369 VA, 208Vac Grid Support Utility Interactive Inverter IQ7HS-66-E-ACM-US, 369 VA, 208Vac Grid Support Utility Interactive Inverter IQ7HS-66-M-US, 369 VA, 208Vac Grid Support Utility Interactive Inverter IQ7HS-66-ACM-US, 384 VA, 240Vac Grid Support Utility Interactive Inverter IQ7HS-66-E-ACM-US, 384 VA, 240Vac Grid Support Utility Interactive Inverter IQ7HS-66-M-US, 384 VA, 240Vac Grid Support Utility Interactive Inverter Regards, Aranjit Sangha Senior Staff Engineer Enphase Energy Inc. 1420 North McDowell Blvd. Petaluma, CA 94954 v: (707) 763-4784 x7098 asangha@enphaseenergy.com 2621 S Glenarbor St - 201821343/6/2024 FLASHLOC is the ultimate attachment for composition shingle and rolled comp roofs. The all-in-one mount installs fast — no kneeling on hot roofs to install flashing, no prying or cutting shingles, no pulling nails. Simply drive the lag bolt and inject sealant into the base. FLASHLOC’s patented TRIPLE SEAL technology preserves the roof and protects the penetration with a permanent pressure seal. Kitted with lag bolts, sealant, and hardware for maximum convenience. Don’t just divert water, LOC it out! PROTECT THE ROOF Install a high-strength waterproof attachment without lifting, prying or damaging shingles. FLASH LOC LOC OUT WATER With an outer shield 1 contour-conforming gasket 2 and pressurized sealant chamber 3 the Triple Seal technology delivers a 100% waterproof connection. Cut Away View HIGH-SPEED INSTALL Simply drive lag bolt and inject sealant into the port 4 to create a permanent pressure seal. Cut Away View FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 3 2 4 1 TESTED TO TAS-100 WIND DRIVEN RAIN TEST AND UL441 RAIN TEST JUNE2021_FLASHLOCCOMP_V2 FASTER INSTALLATION. 25-YEAR WARRANTY. FOR QUESTIONS OR CUSTOMER SERVICE VISIT UNIRAC.COM OR CALL (505) 248-2702 FLASH LOC INSTALLATION GUIDE PRE-INSTALL Snap chalk lines for attachment rows. On shingle roofs, snap lines 1-3/4” below upslope edge of shingle course. Locate rafters and mark attachment locations. At each location, drill a 7/32” pilot hole. Clean roof surface of dirt, debris, snow, and ice. Next, BACKFILL ALL PILOT HOLES WITH SEALANT. NOTE: Space mounts per racking system install specifications. STEP 1: SECURE Place FLASHLOC over pilot hole with lag on down-slope side. Align indicator marks on sides of mount with chalk line. Pass included lag bolt and sealing washer through FLASHLOC into pilot hole. Drive lag bolt until mount is held firmly in place. NOTE: The EPDM in the sealing washer will expand beyond the edge of the metal washer when proper torque is applied. STEP 2: SEAL Insert tip of UNIRAC provided sealant into port. Inject until sealant exits both vents. Follow sealant manufacturer’s instructions. Follow sealant manufacturer’s cold weather application guidelines, if applicable. Continue array installation, attaching rails to mounts with provided T-bolts. NOTE: When FLASHLOC is installed over gap between shingle tabs or vertical joints, fill gap/joint with sealant between mount and upslope edge of shingle course. USE ONLY UNIRAC APPROVED SEALANTS: Chemlink Duralink 50, Chemlink M-1, Geocel 4500, or Geocel S-4 SEALANT GAP 1.75" 2621 S Glenarbor St - 201821343/6/2024 LEGAL NOTICE DRAWING NOT TO SCALE ALL DIMENSIONS ARE NOMINAL PRODUCT PROTECTED BY ONE OR MORE US PATENTS SOLARMOUNT PART DRAWING 4/28/2020 FLASHLOC COMP KIT REVISION DATE: DRAWING TYPE: DESCRIPTION:FL-A01 PRODUCT LINE: 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM SHEET PART TABLE P/N DESCRIPTION 004085M FLASHLOC COMP KIT MILL, 20 PACK 004085D FLASHLOC COMP KIT DARK, 20 PACK 67 8 " 31 2 " 33 4 " 21 4 " 5/16" x 4" SS LAG BOLT W/ SS EPDM BONDED WASHER FLASHLOC BASE MILL OR DARK SS SERRATED T-BOLT SS SERRATED FLANGE NUT 2621 S Glenarbor St - 201821343/6/2024 SunPower® InvisiMount™ | Residential Mounting System Simple and Fast Installation • Integrated module-to-rail grounding • Pre-assembled mid and end clamps • Levitating mid clamp for easy placement • Mid clamp width facilitates consistent, even module spacing • UL 2703 Listed integrated grounding Flexible Design • Addresses sloped and low-sloped residential roofs • Design in landscape and portrait with up to 8ʼ rail span • Pre-drilled rails and rail splice • Rails enable easy obstacle management Customer-Preferred Aesthetics • Best-in-class system aesthetics • Black anodized components • Low-profile mid clamps and capped, flush end clamps Part of Superior System • Best-in-class system reliability and aesthetics • Optional rooftop transition flashing, rail- mounted J-box, and wire management rail clips • Combine with SunPower modules and mySunPower® monitoring app Elegant Simplicity SunPower® InvisiMount™ is a SunPower-designed rail-based mounting system. The InvisiMount system addresses residential sloped roofs and combines faster installation time, design flexibility, and superior aesthetics. Classic InvisiMount is specifically envisioned and engineered to pair with SunPower modules; Universal InvisiMount is compatible with a wide range of modules. The resulting system-level approach amplifies the installation and aesthetic benefits—for homeowners and for installers. sunpower.com Datasheet SunPower® InvisiMount™ | Residential Mounting System InvisiMount Component Details Classic mid clamp Black oxide stainless steel 300 series 63 g (2.2 oz) Universal mid clamp Black anodized aluminum 6000 series 60 g (2.1 oz) Classic end clamp Black anodized aluminum 6000 series 110 g (3.88 oz) Universal end clamp Black anodized aluminum 6000 series 103 g (3.63 oz) Rail Black anodized aluminum 6000 series 830 g/m (9 oz/ft) Rail splice Aluminum alloy 6000 series 830 g/m (9 oz/ft) Rail bolt M10-1.5 × 25 mm; custom T-head SS304 18 g (0.63 oz) Rail nut M10-1.5; DIN 6923 SS304 nominal Ground lug assembly SS304; A2-70 bolt; tin-plated copper lug 106.5 g (3.75 oz) Row-to-row grounding clip SS 301 with SS 304 M6 bolts 75 g (2.6 oz) Row-to-row grounding jumper Stainless steel 300 series 10 g (0.35 oz) Row-to-row spacer Black POM-grade plastic 5 g (0.18 oz) Roof Attachment BOM • InvisiMount Comp Shingle Attachment with Pegasus • InvisiMount Flat Tile Replacement Attachment with Pegasus • InvisiMount S-Tile Replacement Attachment with Pegasus • InvisiMount W-Tile Replacement Attachment with Pegasus InvisiMount Operating Conditions Temperature −40°C to 90°C (−40°F to 194°F) Roof Attachment Hardware Warranties Refer to roof attachment hardware manufacturer’s documentation. InvisiMount Warranties And Certifications Warranties • 25-year product warranty • 5-year finish warranty Certifications • UL 2703 Listed • Class A Fire Rated Professional Engineer (PE) must then stamp all calculations. If you have any questions please contact SunPower Technical Support at 1-855-977-7867. © 2022 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo, EQUINOX, and INVISIMOUNT are trademarks or registered trademarks of SunPower Corporation. All other trademarks are the property of their respective owners. Specifications included in this datasheet are subject to change without notice. InvisiMount Components Mid Clamp End Clamp Rail and Rail SpliceGround Lug Assembly sunpower.com 509506 RevG ¹ With Classic InvisiMount, a module frame that is compatible with the InvisiMount system is required for hardware interoperability; modules without this frame may be used with Universal InvisiMount. ² SunPower recommends that all Equinox™, InvisiMount™, and AC module systems always be designed using the InvisiMount Span Tables #524734. If a designer decides to instead use the component capacities listed in this document to design a system, note that the capacities shown are Load and Resistance Factor Design (LRFD) design loads, and are NOT to be used for Allowable Stress Design (ASD) calculations; and that a licensed InvisiMount Component LRFD Capacities² Classic Mid clamp Uplift 664 lbf Shear 540 lbf Universal Mid clamp Uplift 962 lb Shear 437 lb Classic End clamp Uplift 899 lbf Shear 220 lbf Universal End clamp Uplift 605 lb Shear 242 lb Rail Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft Rail splice Moment: upward 548 lbf-ft Moment: downward 580 lbf-ft L-foot Uplift 1000 lbf Shear 390 lbf Datasheet Row-to-Row Spacer Row-to-Row Grounding Clip Universal End ClampRow-to-row Grounding Jumper (DynoBond) Universal Mid ClampRail and Rail SpliceGround Lug Assembly Universal InvisiMount Classic InvisiMount 2621 S Glenarbor St - 201821343/6/2024 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 1 of 3 GFT-OP-11e (22-August-2019) Test Verification of Conformity Verification Number: 105370452-LAX-VOC1 Applicant Name & Address: SunPower Corporation 1414 Harbour Way South Suite 1901 Richmond, CA 94804 USA Photovoltaic Racking System installed using the SunPower InvisiMount Installation Guide 508988 Rev O Fire Class Rating: Class A for Type 1 and Type 2 Fuse Rating: 20 A Mechanical Load Testing: Mechanical Load Rating: 10PSF Downward, 5PSF Upward, 5PSF Sloped Load Module Orientation: Portrait or Landscape Classic InvisiMount, Universal InvisiMount ; InvisiMount Product Description: Ratings & Principle Characteristics: Models/Type References: Brand Name: Relevant Standards: Verification Issuing Office Name & Address: Date of Tests: Test Report Number(s): Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed.1+R:24Mar2021] Intertek Testing Services NA, Inc. 25800 Commercentre Drive Lake Forest, CA 92630 USA September-27-2022 to October-11-2022 105208800LAX-001 Signature Name: Abdullah Alharbi Position: PV Engineer Date: 12 April 2023 On the basis of the tests undertaken, the samples of the below product have been found to comply with the requirements of the referenced specification/standard at the time the tests were carried out. This verification is part of the full test report 105208800LAX-001 and should be read in conjunction with it. This verification replaces previous verification number 105208800LAX-001-LAX-VOC1 dated: 30-12-2022. Additional information in Appendix. This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 2 of 3 GFT-OP-11e (22-August-2019) APPENDIX: Test Verification of Conformity Approved Module list Module Manufacturer Model SunPower Corporation SPR-XYY-###-(COM), where X can be “E” or “A” denoting cell type, where YY represents numbers 18, 19, 20,21, or blanks and ### represents any number from 450 to 310 and 274 to 233; SPR-EYY-###, where YY represents numbers 18, 19, 20 or 21, and ### represents any number from 345 to 285 and 250 to 225. SPR-MXXX & SPR-MAX6-XXX, may be followed by -BLK, where XXX is 385-440. SPR-E or SPR-X followed by 18, 19, 20, 21, 22, followed by - XXX where XXX is 320-370, may be followed by -BLK, followed by C, D, E, may be followed by -AC SPR-XXXE/NE-WHT/BLK-U-YYYACPV and SPR-V-WW-XXX-Y-Z-G-AC, where "XXX" is the wattage of the panel and ranges from 250 to 225; and where "YYY" indicates the inverter voltage used in the module, and can be blank, 240 or 208/240. SPR-AXXX-G-AC or SPR-AXXXBLK-G-AC Where “XXX” denotes output power. “G” denotes inverters. “BLK” represents backsheet color. “AC” indicates AC module. SPR-AXXX-H-AC where “XXX” is the wattage range of 350 to 425, “H” Denotes the inverter, and “AC” indicates AC modules. SPR-MXXX-YYY-Z-AC, where XXX is 380-440 All models identified must have the Gen 5 frame and have a module fire performance: Type 2 SunPower Corporation 72-cell model with Gen 4.2 frame only: SPR-AXXX-COM or SPR-MAX5-XXX-COM, may be followed by BLK, where XXX is 380-460 66-cell model with Gen 4.2 frame only: SPR-AXXX, may be followed by -COM, and/or - 300V, followed by MLSD, where XXX is 350-425. 72-cell model with Gen 4.2 frame only: SPR-AXXX, may be followed by -COM, and/or - 300V, followed by MLSD, where XXX is 430-60 SPR-UXXX-BLK, where XXX is 395-415 Hanwha Q.PEAK DUO BLK ML-G10.a+ XXX, where XXX is 370-425 Q.PEAK DUO BLK-G10+ XXX, where XXX is 350–370 Q.PEAK DUO BLK ML-G10+ XXX, where XXX is 385-405 REC RECxxxNP2, may be followed by Black, where xxx is 350-380. RECxxxTP4, may be followed by Black, where xxx is 355-380. RECxxxAA Black, where xxx is 340-385. This is an Appendix to Test Verification of Conformity Number: 105370452-LAX-VOC1. 2621 S Glenarbor St - 201821343/6/2024 This Verification is for the exclusive use of Intertek's client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this Verification. Only the Client is authorized to permit copying or distribution of this Verification. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test/inspection results referenced in this Verification are relevant only to the sample tested/inspected. This Verification by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Page 3 of 3 GFT-OP-11e (22-August-2019) RECxxxAA PURE, where xxx is 380-415. Trina TSM-xxxDE06X.05(II), where xxx is 355-380 Canadian Solar CS3N-xxxMS, xxx is 375-435 Waaree WSMDi-XXX, XXX is 360-380, 395-415 WSMDiB-XXX, XXX is 360-380, 395-455 Jinko JKMxxxM-6RL3-B, where xxx is 365-400 Aptos Solar DNA-108-BF10-xxxW, xxx is 385-410. DNA-120-BF26-xxxW, where xxx is 350-370. DNA-120-MF26-xxxW, where xxx is 360-370 The Universal InvisiMount System was evaluated for fire rating with Type 1 and Type 2 modules. Signature Name: Abdullah Alharbi Position: PV Engineer Date: 12 April 2023 2621 S Glenarbor St - 201821343/6/2024 Improve Support, Reduce Costs An intuitive monitoring website enables you to: • • • • See a visual map of customer sites Remotely manage hundreds of sites Remotely diagnose and troubleshoot system issues Drill down for the status of individual devices Add Value for Customers With mySunPower™ monitoring customers can: • • • • • Track their energy production by day, month, year and in different weather conditions See their energy use and estimated bill savings Maximize their savings with automatic system alerts and tips Customize storage settings and easily monitor and track available battery power Receive elective system reports SunPower® Monitoring — Plug-and-Play Installation This complete solution for residential monitoring and control includes the SunPower® PV Supervisor (PVS) which improves the installation process, overall system reliability, and customer experience: • • • • • • • • • Compact footprint for improved aesthetics Robust cloud connectivity and comprehensive local connectivity Flexible configuration of devices during installation Consumption metering Revenue-quality production metering Web-based commissioning Remote diagnostics of PVS and inverters Durable UL Type 3R enclosure helps reduce maintenance costs Easy integration with SunPower eBOS Robust Cloud Connectivity Multiple options to maintain optimal connectivity: • • • Hardwired Ethernet WiFi Cellular backup sunpower.com SunPower® Monitoring | Residential SunPower PV Supervisor Operating Conditions Temperature • −22°F to +140°F (−30°C to +60°C) Humidity (max.)• 95%, non-condensing Warranty and Certifications Warranty • 10-year Limited Warranty Certifications • UL, cUL, CE, UL 61010-1 and -2, FCC Part 15 (Class B) Mechanical Weight • 5.5 lb (2.5 kg) Dimensions • 11.8 × 8.0 × 4.2 in. (30.5 × 20.5 × 10.8 cm) Enclosure rating • UL 50E Type 3R Site Requirements Number of modules supported per PVS • 85 (SunPower AC modules) Internet access • High-speed internet access via accessible router or switch Power • 100–240 VAC (L–N), 50 or 60 Hz • 208 VAC (L–L in phase 3), 60 Hz Communication RS-485 • Supports string inverters, external meters, and other auxiliary devices Integrated metering • One channel of revenue-quality production metering • Two channels of consumption metering Ethernet • 1 LAN (or optional WAN) port PLC • Supports SunPower AC modules WiFi • 802.11b/g/n 2.4 GHz and 5 GHz Cellular • LTE Cat-M1/3G UMTS ZigBee • IEEE 802.15.4 MAC, 2.4 GHz ISM band Data storage • 60 days Upgrades • Automatic firmware upgrades Web and Mobile Device Support Customer site • mysunpower.com Partner site • monitor.sunpower.com Browsers • Firefox, Safari, and Chrome Mobile devices • iPhone®, iPad®, and Android™ Customer app 1 Create account online at mysunpower.com 2 On a mobile device, download the SunPower Monitoring app from Apple App Store or Google Play™ Store 3 Sign in using account email and password SunPower® AC ModulesPVSSunPower® Pro Fleet Management for Installers mySunPowerTM for Homeownes © 2020 SunPower Corporation. All Rights Reserved. SUNPOWER, the SUNPOWER logo and MYSUNPOWER are trademarks or registered trademarks of SunPower Corporation in the U.S. and other countries as well. All other logos and trademarks are the properties of their respective owners. 530536 Rev D 2621 S Glenarbor St - 201821343/6/2024 Equinox Junction Boxes SunPower®Equinox™ Accessories SPECIFICATIONS Model RMJ v2 Comp Shingle Transition J-Box Kit Part Number 530167 530168 Max. Voltage Rating 600 V (AC or DC) Ambient Temp. Range −35°C to 75°C (−31°F to 167°F) Enclosure Material Flame-retardant, UV-resistant, high-impact resistant resin Attachment/Flashing Material 304 stainless steel Steel w/zinc-aluminum coating Cavity Dimensions 150 × 150 × 62 mm (5.91” × 5.91” × 2.13”) Enclosure Volume 1150 cc (70 in3) Attachment/Flashing Finish Black oxide Black powder coat Compatibility InvisiMount rail Comp shingle roofs Assembled Weight 0.78 kg (1.7 lb)1.27 kg (2.8 lb) Certifications & Ratings •Watertight, UL Type 4 •UL 94 5VA •UL 1741 •UL 2703 (with InvisiMount) •Watertight, UL Type 4 •UL 94 5VA •UL 1741 Additional Hardware Included •3/4″ cord grip •Lay-in lug •3/4″cord grip •#12 screws with EPDM washer Composition Shingle Roof Transition Junction Box Datasheet InvisiMount™ Rail-Mounted Junction Box (RMJ) v2 •70% larger than original InvisiMount J-box. •Integrated grounding to InvisiMount rail, replacing grounding lug assembly. •Snap-on attachment for fast and secure installation. •Enables transitioning conductors directly through the roof. •Integrated flashing for peace of mind. •Compatible with composition shingle roofs. COMPONENT DIMENSIONS J- Bo x E n c l o s u r e (us e d i n bo t h R M J a n d T r a n s i t i o n J- bo x ) Fl a s h i n g (u s e d o n l y w i t h T r a n s i t i o n J -Bo x ) Equinox Junction Boxes SunPower®Equinox™ Accessories Datasheet 539382 RevA 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 SPAN TABLES, INVISIMOUNT 22 SQ. FT. MODULE WITH COMPOSITE SHINGLE - MOUNTING ROOF ATTACHMENT ASCE 7-16 VERSION Item Number: 524734 8-25-22 Ethan Ely REVISION HISTORY REV. DCR# DESCRIPTION DATE AUTHOR A DCO-008990 • Initial Release 4-10-17 P. Todd B DCO-010454 • Exposure D added. 10-10-17 G. Rossi C DCO-010454 • A-Series Modules Added. • Color coding of Span Tales Added. 6-11-19 E. Ely D DCR-003763 • CA Only • ASCE 7-16 Update 2-20-20 J. Mansell E DCR-003794 • Module Pressure Capacities Increased • Expanded for all States 4-27-20 J. Mansell F DCR-003922 • M-series module added 9-21-21 E. Ely G TBD • Version for Universal InvisiMount system 8-25-22 E. Ely Instructions: 1. Tables in this document have been generated from the Excel tool, item #524735 2. See the Engineering Certification Letter for Professional Engineer stamp. 3. Delete this first page when printing. 4. The Span Tables are split among several volumes due to the various combinations of Modules + Attachments + Applicable Codes. 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 List of Volumes Standard Volumes 1. 22 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-10 2. 22 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-16 3. 22 Sq. Ft. Module + Tile Attachment w/ ASCE 7-10 4. 22 Sq. Ft. Module + Tile Attachment w/ ASCE 7-16 High Loading Volumes 5. High Wind Speeds: 22 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-10 6. High Wind Speeds: 22 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-16 7. High Wind Speeds: 22 Sq. Ft. Module + Tile Attachment w/ ASCE 7-16 8. High Wind Speeds: 20 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-10 9. High Wind Speeds: 20 Sq. Ft. Module + Composite Shingle Attachment w/ ASCE 7-16 10. High Wind Speeds: 20 Sq. Ft. Module + Tile Attachment w/ ASCE 7-16 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 Document #524734 Rev G, Vol. 2 1 SunPower Proprietary InvisiMount Span Tables Engineering Summary Letter Volume: 2 ASCE 7 Version: 7-16 Module Type: 22 Sq. Ft. Module Roof Attachment: Composite Shingle High Wind: No High Snow: No The Span Tables are divided into two Parts: • Part 1: Simplified Tables (Wind Tunnel Loads) • Part 2: General Tables (ASCE 7 Analytical Method) Part 1 features spans based on forces on the InvisiMount system using exposure coefficients, GCp, provided by a Wind Tunnel Test Report by Cermak, Petrka, & Petersen (CPP). These values provide a more accurate and economical solution but apply to less configurations. It is recommended to use these values whenever possible, and when not, to use the spans provided in Part 2. Approved Attachments: The following span tables are adequate for the following roof attachments: • SunPower InvisiMount L-Foot attachment • Pegasus Composite Shingle Roof Attachment o And roof attachments with capacities equal to or greater than all of the following Load and Resistance Factor Design (LRFD) values: ▪ Tension – 1000lb ▪ Compression – 1000lb ▪ Shear – 390lb Scope: • Module orientations: Portrait & Landscape • Gable and Hip roofs only with modules not in the overhang sections of the roof • Roof heights o 30ft (Part 1 only) o 20-60ft (Part 2 only) • Roof Slope o 4:12 to 8:12 (Part 1 only) o 2:12 to 12:12 (Part 2 only) • Exposures Categories B, C, D • Basic Wind Speeds: o ASCE 7-10: 110-140mph – High Wind: 145-180mph o ASCE 7-16: 90-130mph – High Wind: 135-180mph • Ground Snow Loads: o 0-60psf (10psf increments) o High Snow Volumes: 80-200psf (20psf increments) o High Wind Volumes: 0psf 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 Document #524734 Rev G, Vol. 2 2 SunPower Proprietary Module Size and Capacity: • These tables are applicable to modules with the following dimensions: o Maximum length: 6.56 ft. (2.00 m) o Maximum surface area: 22 sq. ft. (2.04 sq. m) o Maximum height: 1.57 in. (40 mm) • These tables do not include a check of the module’s capacity. A module check must be performed by the user in addition to identifying the appropriate span. • In the Part 1 (Wind Tunnel-based) span tables, module pressures are provided adjacent to the corresponding spans. These module pressures are derived from the Wind Tunnel Test Report for each output condition. The user must confirm that the design capacities of the module to be used are greater than both the uplift and downforce pressured identified. • For the Part 2 span tables, pressure on the module must be calculated per the appropriate ASCE code (7-10 or 7-16). • A summary of the equations required to calculate these values is provided in the following section. 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 Document #524734 Rev G, Vol. 2 3 SunPower Proprietary Module Pressure Calculation (ASCE 7-16): • The following equations reflect ASCE-prescribed calculations, with values specific to InvisiMount included where possible. • Note that some conservative assumptions have been made and, in some cases, the resulting values may be more conservative than a site-specific iteration of the ASCE-based calculations. • The below equations are applicable only to modules with an area equal to or greater than 19.5 ft^2. • See below glossary for definitions of all referenced variables. • ASCE 7 §2.3 defines load combination equations for LRFD, which generate design load pressures. The controlling equations which define the design load on the module are: o 𝑷𝒖𝒑=𝟎.𝟗𝑫+𝟏.𝟎𝑾𝒖𝒑 o 𝑷𝒅𝒐𝒘𝒏=𝑴𝒂𝒙{𝟏.𝟐𝑫+𝟏.𝟔𝑺+𝟎.𝟓𝑾𝒅𝒐𝒘𝒏 𝟏.𝟐𝑫+𝟏.𝟎𝑾𝒅𝒐𝒘𝒏+𝟎.𝟓𝑺 • The process for solving for these equations is as follows: o Identify site-specific inputs: ▪ 𝒛 =[ ] 𝑓𝑡 ▪ 𝑬 =[ 𝐵 / 𝐶 / 𝐷 ] ▪ 𝑽 =[ ] 𝑚𝑝ℎ ▪ 𝒑𝒈=[ ] 𝑝𝑠𝑓 ▪ 𝜽 =[ ] 𝑑𝑒𝑔𝑟𝑒𝑒𝑠 ▪ 𝒁𝒐𝒏𝒆=[ 1 / 2 / 3 ] o Select the following coefficients from the below Look-up Tables: ▪ 𝒛𝒈 =[ ] 𝑓𝑡 ▪ 𝑪𝒆 =[ ] ▪ 𝜶 =[ ] ▪ 𝑮𝑪𝒑,−=[ ] ▪ 𝑮𝑪𝒑,+=[ ] o Use the following equations to establish wind and snow loads: ▪ The minimum allowable value for 𝑊𝑢𝑝 & 𝑊𝑑𝑜𝑤𝑛 is 16 psf. ▪ Wind, Uplift: 𝑾𝒖𝒑 =𝟎.𝟎𝟎𝟑𝟏𝟔𝟓(𝒛 𝒛𝒈 ) 𝟐 𝜶∗𝑽𝟐∗𝑮𝑪𝒑,− ▪ Wind, Downforce: 𝑾𝒅𝒐𝒘𝒏=𝟎.𝟎𝟎𝟐𝟑𝟔𝟐∗(𝒛 𝒛𝒈 ) 𝟐 𝜶∗𝑽𝟐∗𝑮𝑪𝒑,+ ▪ Snow: 𝑺 =𝒑𝒔,𝒈𝒓∗𝐜𝐨𝐬(𝜽) If 𝜃≥15°, 𝑝𝑠,𝑔𝑟=0.84 ∗𝐶𝑒∗𝑝𝑔 If 𝜃<15° 𝐴𝑁𝐷 𝑝𝑔<20 𝑝𝑠𝑓, 𝑝𝑠,𝑔𝑟=𝑝𝑔 If 𝜃<15° 𝐴𝑁𝐷 𝑝𝑔>20 𝑝𝑠𝑓, 𝑝𝑠,𝑔𝑟=𝑀𝑎𝑥{20 𝑝𝑠𝑓 0.84 ∗𝐶𝑒∗𝑝𝑔 o Add the resulting load pressures in the load combination equations (dead load is provided): ▪ 𝑷𝒖𝒑=𝟐.𝟓 𝒑𝒔𝒇+𝟏.𝟎𝑾𝒖𝒑 ▪ 𝑷𝒅𝒐𝒘𝒏=𝑴𝒂𝒙{𝟑.𝟓 𝒑𝒔𝒇+𝟏.𝟔𝑺+𝟎.𝟓𝑾𝒅𝒐𝒘𝒏 𝟑.𝟓 𝒑𝒔𝒇+𝟏.𝟎𝑾𝒅𝒐𝒘𝒏+𝟎.𝟓𝑺 2621 S Glenarbor St - 201821343/6/2024 SUNPOWER CORPORATION Document #524734 Rev G SPAN TABLES, INVISIMOUNT Template FILE-074910, Ed. 2 Document #524734 Rev G, Vol. 2 4 SunPower Proprietary • Look-up Tables o Exposure-based coefficients: Exposure 𝑪𝒆 𝜶 𝒛𝒈 B 0.9 7 1200 C 0.9 9.5 900 D 0.8 11.5 700 o External pressure coefficients: ▪ These values are based on a minimum module size of 19.5 ft^2. ASCE 7-16 Gable Roof Hip Roof 7 < θ <= 20 20 < θ <= 27 27 < θ <= 45 7 < θ <= 20 20 < θ <= 27 Gcp,- Zone 1 -2.000 -1.500 -1.510 -1.800 -1.226 Zone 2 -2.585 -2.179 -1.777 -2.333 -1.777 Zone 3 -3.078 -2.471 -2.200 -2.333 -1.777 Gcp,+ All Zones 0.467 0.467 0.784 0.584 0.584 ASCE 7-16 Hip Roof θ = 30.26 (7:12) θ = 33.69 (8:12) θ = 36.87 (9:12) θ = 39.81 (10:12) θ = 42.51 (11:12) θ = 45 (12:12) Gcp,- Zone 1 -1.062 -1.126 -1.185 -1.239 -1.290 -1.336 Zone 2 -1.265 -1.419 -1.561 -1.693 -1.814 -1.926 Zone 3 -1.413 -1.541 -1.647 -1.735 -1.808 -1.866 Gcp,+ All Zones 0.551 0.551 0.551 0.551 0.551 0.551 • Glossary of variables: o 𝑃𝑢𝑝=𝑚𝑜𝑑𝑢𝑙𝑒 𝑢𝑝𝑙𝑖𝑓𝑡 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 o 𝑃𝑑𝑜𝑤𝑛=𝑚𝑜𝑑𝑢𝑙𝑒 𝑑𝑜𝑤𝑛𝑓𝑜𝑟𝑐𝑒 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 o 𝐷=𝑑𝑒𝑎𝑑 𝑙𝑜𝑎𝑑=2.7 𝑝𝑠𝑓 o 𝑊𝑢𝑝=𝑢𝑝𝑙𝑖𝑓𝑡 𝑤𝑖𝑛𝑑 𝑙𝑜𝑎𝑑 (𝑝𝑠𝑓) o 𝑊𝑑𝑜𝑤𝑛=𝑑𝑜𝑤𝑛𝑓𝑜𝑟𝑐𝑒 𝑤𝑖𝑛𝑑 𝑙𝑜𝑎𝑑 (𝑝𝑠𝑓) o 𝑆=𝑠𝑛𝑜𝑤 𝑙𝑜𝑎𝑑 (𝑝𝑠𝑓) o 𝑧=𝑟𝑜𝑜𝑓 ℎ𝑒𝑖𝑔ℎ𝑡 (𝑓𝑡) o 𝐸=𝑒𝑥𝑝𝑜𝑠𝑢𝑟𝑒 (𝐵,𝐶,𝑜𝑟 𝐷) o 𝑣=𝑤𝑖𝑛𝑑 𝑠𝑝𝑒𝑒𝑑 (𝑚𝑝ℎ) o 𝑝𝑔 =𝑔𝑟𝑜𝑢𝑛𝑑 𝑠𝑛𝑜𝑤 𝑙𝑜𝑎𝑑 (𝑝𝑠𝑓) o 𝜃=𝑟𝑜𝑜𝑓 𝑝𝑖𝑡𝑐ℎ (𝑑𝑒𝑔𝑟𝑒𝑒𝑠) o 𝑍𝑜𝑛𝑒=𝑟𝑜𝑜𝑓 𝑧𝑜𝑛𝑒 (1,2,𝑜𝑟 3) o 𝑧𝑔=𝑔𝑟𝑎𝑑𝑖𝑒𝑛𝑡 ℎ𝑒𝑖𝑔ℎ𝑡 (𝑓𝑡) o 𝛼=𝑔𝑢𝑠𝑡 𝑝𝑟𝑜𝑓𝑖𝑙𝑒 𝑓𝑎𝑐𝑡𝑜𝑟 o 𝐶𝑠=𝑅𝑜𝑜𝑓 𝑠𝑙𝑜𝑝𝑒 𝑓𝑎𝑐𝑡𝑜𝑟 o 𝐶𝑒=𝑒𝑥𝑝𝑜𝑠𝑢𝑟𝑒 𝑓𝑎𝑐𝑡𝑜𝑟 o 𝐺𝐶𝑝,−= 𝑒𝑥𝑡𝑒𝑟𝑛𝑎𝑙 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑐𝑜𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑡,𝑢𝑝𝑙𝑖𝑓𝑡 o 𝐺𝐶𝑝,+= 𝑒𝑥𝑡𝑒𝑟𝑛𝑎𝑙 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑐𝑜𝑒𝑓𝑓𝑖𝑐𝑖𝑒𝑛𝑡,𝑑𝑜𝑤𝑛𝑓𝑜𝑟𝑐𝑒 o 𝑝𝑠=𝑠𝑙𝑜𝑝𝑒𝑑 𝑟𝑜𝑜𝑓 𝑠𝑛𝑜𝑤 𝑙𝑜𝑎𝑑 o 𝑝𝑠,𝑔𝑟=𝑠𝑛𝑜𝑤 𝑙𝑜𝑎𝑑,𝑖𝑛 𝑑𝑖𝑟𝑒𝑐𝑡𝑖𝑜𝑛 𝑜𝑓 𝑔𝑟𝑎𝑣𝑖𝑡𝑦 2621 S Glenarbor St - 201821343/6/2024 Document #524734 Rev G, Vol. 2 5 SunPower Proprietary Inputs (ASCE 7-16): The following tables list the allowable spacing of attachment points for the SunPower InvisiMount mounting system. The following building codes and standards were used in the calculations: • International Building Code (IBC 2018) • International Residential Code (IRC 2018) • Minimum Design Loads for Buildings and Other Structures (ASCE 7-16) • Aluminum Design Manual (ADM1), 2015 • National Design Specification (NDS) for Wood Construction, 2018 The International Building Code is either adopted fully or mostly by each state. The accompanying Engineering Certification Letter lists the building code for the state which this project. Loads on the system were calculated in accordance with ASCE 7-16, using the following parameters: • Risk Category II • Dead Load: System weight (including PV modules and rails) = 2.7 psf • Roof Live Load: 0psf – No live load acts on top of the PV modules • Roof Snow Load Data: o Ground snow load, pg, as indicated in the tables (Fig. 7-1) o Thermal factor, Ct = 1.2, ‘unheated and open-air structures’ (Table 7.3-2) o Exposure factor, Ce = 0.9, ‘fully exposed’ (Table 7.3-1) o Slope factor, Cs, varies with slope and assumes the array is an ‘unobstructed slippery surface’ where snow is free to slide off the array (Figure 7.4-1) • Wind Design Data (Designed per Chapter 30, Components & Cladding): o With modifications to GCp values per SEAOC PV2-2017 o Basic Design Wind speed, V, and exposure category as indicated in the tables (Figure 26.5-1B) o Roof height and slope as indicated in the tables (§26.2) o Topographic factor, Kzt = 1.0 (Table 26.6-1) o Directionality factor, Kd = 0.85 (Table 26.6-1) o Velocity Coefficient, Kh = 2.01(z/zg)^(2/a) (as indicated in Table 26.10-1) o Velocity Pressure Exposure Coefficient, Ke=1 (Table 26.9.1) o Pressure coefficients, GCp, per either wind tunnel testing or Chapter 30 (see notes below tables) • Earthquake Design Data (Designed per Chapter 13: Non-structural Components) o Seismic Design Category E, Soil Site Class D assumed o Mapped MCE Short Period, 0.2sec, Ss = 3.73g, maximum in the United States (Fig. 22 -1) o Mapped MCE Short Period, 1sec, S1 = 1.39g (Fig. 22-2) o Importance Factor, Ip = 1.0 (§13.1.3) o Amplification Factor, ap=1.0 (Table 13.6-1) o Response Factor, Rp=1.5 (Table 13.6-1) • Load combinations per IBC §1605, using Load and Resistance Factor Design (LRFD) 2621 S Glenarbor St - 201821343/6/2024 Document #524734 Rev G, Vol. 2 6 SunPower Proprietary Methodology: The maximum allowable spans shown in the tables are based on a combination of dead, wind, seismic, and snow loads calculated from the inputs above and combined using LRFD combinations. The maximum forces are then compared to the minimum capacities determined in the following ways: • Rail bending and shear: ADM1 LRFD checks • Rail to roof attachment: SunPower Test Reports of the rail bolt between the rail and the roof attachment. • Roof attachment: Manufacturer product information • Roof attachment to rafter: Lag screw withdrawal and shear per NDS • The reported maximum spacing is the greatest allowed spacing, rounded down to the nearest rafter spacing increment, for which the demand/capacity ratios are less than or equal to 1.0, assuming both 16” and 24” rafter spacings. • These tables do not consider the strength of the supporting roof structure. In areas of low snow load, the weight of the array is often considered to offset the design live load of the roof, since personnel and equipment cannot be placed on top of the array. It is recommended to stagger attachment points, as shown in Figure 1, to evenly distribute loads to the rafters. Figure 1 • These tables assume that each module is installed centered over a pair of rails, as shown in Figure 2(a). In cases where one rail is closer to the midpoint of the module, as shown in Figure 2(b), adjustments to the spacing may be required. Figure 2 2621 S Glenarbor St - 201821343/6/2024 Document #524734 Rev G, Vol. G 29 SunPower Proprietary InvisiMount Span Tables Part 2: General Tables (ASCE 7 Analytical Method) How to Use These Tables • Determine the snow load and roof height for the site and select the corresponding table. • Determine the wind speed and roof slope for the site. The value in the table, for this wind speed and roof slope, is the allowable span between attachment points, in inches. • See figure below for locations of zones 1, 2 and 3. Dimension “a” is 10% of the least horizontal dimension or 0.4h, whichever is smaller, but not less than either 4% of the least horizontal dimension or 3 feet. 2621 S Glenarbor St - 201821343/6/2024 Notes: • Tables are based on strength of the InvisiMount rail and approved roof attachment in the Engineering Summary Letter of this document, in conformance with IBC and referenced standards. • Maximum allowable cantilever is equal to 1/3 of the allowable span. • Wind speeds are ultimate values in mph, as defined in ASCE 7. Wind pressure coefficients are derived from ASCE 7 Chapter 30. • User is responsible for verifying the strength of the roof. • User is responsible for verifying the capacity of the module. Refer to the section of this document titled “Module Pressure Calculation”, or the appropriate ASCE code (7-10 or 7-16), for instructions on calculating the uplift and downforce module pressures. Document #524734 Rev G, Vol. 2 95 SunPower Proprietary Exposure C Ground Snow (psf) 0 Roof Height (ft) 20 INVISIMOUNT ALLOWABLE SPANS - ZONE 1 (IN) Slope → 9.46 ° 14.04 ° 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° 36.87 ° 39.81 ° 42.51 ° 45 ° Speed↓ 2:12 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12 90 96 96 96 96 96 96 96 96 96 96 96 95 96 96 96 96 96 96 96 96 96 96 96 100 96 96 96 96 96 96 96 96 96 96 96 105 80 80 80 96 96 96 96 96 96 96 96 110 80 80 80 96 96 96 96 96 96 96 96 120 72 72 72 80 80 80 80 80 80 80 80 130 72 72 72 80 80 80 80 80 80 80 80 INVISIMOUNT ALLOWABLE SPANS - ZONE 2 (IN) Slope → 9.46 ° 14.04 ° 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° 36.87 ° 39.81 ° 42.51 ° 45 ° Speed↓ 2:12 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12 90 80 80 80 96 96 96 96 96 96 96 96 95 80 80 80 96 96 96 96 96 96 96 96 100 80 80 80 80 80 96 96 96 96 96 96 105 72 72 72 80 80 96 96 96 96 96 96 110 72 72 72 80 80 80 80 80 80 80 80 120 48 48 48 72 72 80 80 80 80 80 72 130 48 48 48 64 64 72 72 72 72 72 64 INVISIMOUNT ALLOWABLE SPANS - ZONE 3 (IN) Slope → 9.46 ° 14.04 ° 18.43 ° 22.62 ° 26.57 ° 30.26 ° 33.69 ° 36.87 ° 39.81 ° 42.51 ° 45 ° Speed↓ 2:12 3:12 4:12 5:12 6:12 7:12 8:12 9:12 10:12 11:12 12:12 90 80 80 80 96 96 96 96 96 96 96 96 95 72 72 72 80 80 96 96 96 96 96 96 100 72 72 72 80 80 80 80 80 80 80 80 105 64 64 64 72 72 80 80 80 80 80 80 110 48 48 48 72 72 80 80 80 80 80 80 120 48 48 48 64 64 72 72 72 72 72 72 130 48 48 48 48 48 64 64 64 48 48 48 2621 S Glenarbor St - 201821343/6/2024 2621 S Glenarbor St - 201821343/6/2024 2621 S Glenarbor St - 201821343/6/2024