Loading...
HomeMy WebLinkAbout2801 W Elder Ave & Unit# 2 - PlanPREPARED: ANH PHAN Bldg #'s 101120236-37 APPROVALS: PLNG - F. Arias BLDG - CSG POLICE - B. Martin PUBLIC WORKS - B. Sarlak 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025 N1 CAL GREEN REQUIREMENTS Job # Sheet No.: Scale Date OWNER: SEAL: SHEET DESCRIPTION : 9/27/24 JAMES LE 2801 W ELDER AVE, SANTA ANA, CA 92704 949 - 331 - 8396 23190 DATE REVISIONSNO: REVISIONS 9636 GARDEN GROVE BLVD, #7 GARDEN GROVE, CA 92844 TEL: 714 - 487 - 7926 APDESIGNCA@GMAIL.COM AP DESIGN CONSULTING, INC Pr o j e c t f o r : NE W A T T A C H E D A D U 28 0 1 W E L D E R A V E A N D 28 0 1 W E L D E R A V E # 2 , SA N T A A N A , C A 9 2 7 0 4 PREPARED: ANH PHAN 2801 W Elder Ave & Unit# 24/15/2025 T24.1 TITLE 24 - ADU Job # Sheet No.: Scale Date OWNER: SEAL: SHEET DESCRIPTION : 9/27/24 JAMES LE 2801 W ELDER AVE, SANTA ANA, CA 92704 949 - 331 - 8396 23190 DATE REVISIONSNO: REVISIONS 9636 GARDEN GROVE BLVD, #7 GARDEN GROVE, CA 92844 TEL: 714 - 487 - 7926 APDESIGNCA@GMAIL.COM AP DESIGN CONSULTING, INC Pr o j e c t f o r : NE W A T T A C H E D A D U 28 0 1 W E L D E R A V E A N D 28 0 1 W E L D E R A V E # 2 , SA N T A A N A , C A 9 2 7 0 4 PREPARED: ANH PHAN 2801 W Elder Ave & Unit# 24/15/2025 Job # Sheet No.: Scale Date OWNER: SEAL: SHEET DESCRIPTION : 9/27/24 JAMES LE 2801 W ELDER AVE, SANTA ANA, CA 92704 949 - 331 - 8396 23190 DATE REVISIONSNO: REVISIONS 9636 GARDEN GROVE BLVD, #7 GARDEN GROVE, CA 92844 TEL: 714 - 487 - 7926 APDESIGNCA@GMAIL.COM AP DESIGN CONSULTING, INC Pr o j e c t f o r : NE W A T T A C H E D A D U 28 0 1 W E L D E R A V E A N D 28 0 1 W E L D E R A V E # 2 , SA N T A A N A , C A 9 2 7 0 4 T24.2 TITLE 24 CONT. PREPARED: ANH PHAN 2801 W Elder Ave & Unit# 24/15/2025 DATE:7/9/2024 2801 W ELDER AVE, UNIT 2 (ADU) SANTA ANA, CA 92704 STRUCTURAL CALCULATIONS FOR Pro ect: NEW ATTACHED ADU ADDRESS: Page 1 of 22 2801 W Elder Ave & Unit# 24/15/2025 Project:NEW ATTACHED ADU Address:2801 W Elder Ave, UNIT 2 (ADU), Santa Ana, CA 92704 DATE: 07/09/24 ROOF:SHINGLE Slope 5:12 Live Load 20 psf Roof'g Material 4 psf Sheathing 1.5 psf Trusses / Rafters 2.0 psf Ceiling Joists 2.0 psf Drywall 1.5 psf Sprinkler 0.5 psf Solar 3.0 psf Miscellaneous 0.5 psf Total D.L.15 psf Total Load 35 psf EXTERIOR WALL: EXTERIOR:9 DRYWALL:3.0 STUDS:2.0 MISC.:1.0 DL=15.0 PSF INTERIOR WALL: DRYWALL:3 DRYWALL:3.0 STUDS:2.0 MISC.:2.0 DL=10.0 PSF LOADING CONDITIONS Page 2 of 22 2801 W Elder Ave & Unit# 24/15/2025 ASCE Hazards Report Address: 2801 W Elder Ave Santa Ana, California 92704 Standard:ASCE/SEI 7-16 Latitude:33.729535 Risk Category:II Longitude:-117.906855 Soil Class:D - Default (see Section 11.4.3) Elevation:60.482227329132 ft (NAVD 88) Wind Results: Wind Speed 95 Vmph 10-year MRI 66 Vmph 25-year MRI 72 Vmph 50-year MRI 76 Vmph 100-year MRI 81 Vmph Data Source: ASCE/SEI 7-16, Fig. 26.5-1B and Figs. CC.2-1–CC.2-4, and Section 26.5.2 Date Accessed: Tue Jul 09 2024 Value provided is 3-second gust wind speeds at 33 ft above ground for Exposure C Category, based on linear interpolation between contours. Wind speeds are interpolated in accordance with the 7-16 Standard. Wind speeds correspond to approximately a 7% probability of exceedance in 50 years (annual exceedance probability = 0.00143, MRI = 700 years). Site is not in a hurricane-prone region as defined in ASCE/SEI 7-16 Section 26.2. Page 1 of 3https://ascehazardtool.org/Tue Jul 09 2024 Page 3 of 22 2801 W Elder Ave & Unit# 24/15/2025 SS : 1.306 S1 : 0.467 F a : 1.2 F v : N/A SMS : 1.567 SM1 : N/A SDS : 1.045 SD1 : N/A T L : 8 PGA : 0.558 PGA M : 0.669 F PGA : 1.2 Ie : 1 C v : 1.361 Seismic Site Soil Class: Results: Data Accessed: Date Source: D - Default (see Section 11.4.3) USGS Seismic Design Maps Ground motion hazard analysis may be required. See ASCE/SEI 7-16 Section 11.4.8. Tue Jul 09 2024 Page 2 of 3https://ascehazardtool.org/Tue Jul 09 2024 Page 4 of 22 2801 W Elder Ave & Unit# 24/15/2025 The ASCE Hazard Tool is provided for your convenience, for informational purposes only, and is provided “as is” and without warranties of any kind. The location data included herein has been obtained from information developed, produced, and maintained by third party providers; or has been extrapolated from maps incorporated in the ASCE standard. While ASCE has made every effort to use data obtained from reliable sources or methodologies, ASCE does not make any representations or warranties as to the accuracy, completeness, reliability, currency, or quality of any data provided herein. Any third-party links provided by this Tool should not be construed as an endorsement, affiliation, relationship, or sponsorship of such third-party content by or from ASCE. ASCE does not intend, nor should anyone interpret, the results provided by this Tool to replace the sound judgment of a competent professional, having knowledge and experience in the appropriate field(s) of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the contents of this Tool or the ASCE standard. In using this Tool, you expressly assume all risks associated with your use. Under no circumstances shall ASCE or its officers, directors, employees, members, affiliates, or agents be liable to you or any other person for any direct, indirect, special, incidental, or consequential damages arising from or related to your use of, or reliance on, the Tool or any information obtained therein. To the fullest extent permitted by law, you agree to release and hold harmless ASCE from any and all liability of any nature arising out of or resulting from any use of data provided by the ASCE Hazard Tool. Page 3 of 3https://ascehazardtool.org/Tue Jul 09 2024 Page 5 of 22 2801 W Elder Ave & Unit# 24/15/2025 DESIGN AND MATERIAL SPECIFICATIONS (OC) BUILDING CODE: CBC 2022 Fb F F E BEAMS 5" OR MORE THICK - NO. 1 1350 675 85 1.6 POSTS 5" OR MORE THICK - NO. 1 1350 675 85 1.6 P.S.L BEAMS ESR - 1387 2900 2025 290 2 DOUGLAS FIR - LARCH - NO. 2 875 575 95 1.6 REINFORCING STEEL:STM A615, GRADE 40 STRUCTURAL STEEL:GRADE A36 FOUNDATIONS: SSUME SOIL PRESSURE IS 1500 PSF CONCRETE:2500 PSI UNLESS OTHERWISE SPECIFIED MASONRY:1900 PSI GROUT : TYPE M LUMBER: ALL STRUCTURAL MEMBERS SHALL BE DOUGLAS FIR-LARCH UNLESS Page 6 of 22 2801 W Elder Ave & Unit# 24/15/2025 Level Member Name Results (Max UTIL %)Current Solution Comments R1: 2X6 R.R. @ 16" O.C.Passed (101% ΔT)1 piece(s) 2 x 6 DF No.2 @ 16" OC C1: 2X6 C.J. @ 16" O.C.Passed (100% ΔT)1 piece(s) 2 x 6 DF No.2 @ 16" OC BM1: HIP BEAM AT BED #1 Passed (38% M)1 piece(s) 2 x 8 DF No.2 BM2: BEAM AT BED #1 Passed (63% M)1 piece(s) 4 x 10 DF No.2 BM3: BEAM AT LIVING Passed (95% ΔT)1 piece(s) 4 x 8 DF No.2 BM4: HEADER AT BED #1 Passed (65% M)1 piece(s) 4 x 8 DF No.2 23190 - 2801 W Elder Ave JOB SUMMARY REPORT ForteWEB Software Operator Job Notes 7/9/2024 7:20:42 AM UTC Anh Phan AP DESIGN (714) 487-7926 anhtuanxd04@gmail.com ForteWEB v3.8 File Name: 23190 - 2801 W Elder Ave Page 1 / 8 Page 7 of 22 2801 W Elder Ave & Unit# 24/15/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)284 @ 2 1/2"2231 (3.50")Passed (13%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)253 @ 8 9/16"1238 Passed (20%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)887 @ 6' 8"1060 Passed (84%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.589 @ 6' 8"0.700 Passed (L/285)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.940 @ 6' 8"0.933 Passed (L/179)--1.0 D + 1.0 Lr (All Spans) Member Length : 14' 7 5/8" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 5/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Beveled Plate - SPF 3.50"3.50"1.50"106 178 284 Blocking 2 - Beveled Plate - SPF 3.50"3.50"1.50"106 178 284 Blocking •Maximum allowable bracing intervals based on applied load. •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)7' 3" o/c Bottom Edge (Lu)14' 5" o/c Dead Roof Live Vertical Load Location (Side)Spacing (0.90)(1.25)Comments 1 - Uniform (PSF)0 to 13' 4"16"11.0 20.0 Default Load Member Notes 2X6 R.R. @ 16" O.C. (MAX SPAN = 12'-9") Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by AP DESIGN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level , R1: 2X6 R.R. @ 16" O.C. 1 piece(s) 2 x 6 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 7/9/2024 7:20:42 AM UTC Anh Phan AP DESIGN (714) 487-7926 anhtuanxd04@gmail.com ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 File Name: 23190 - 2801 W Elder Ave Page 2 / 8 Page 8 of 22 2801 W Elder Ave & Unit# 24/15/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)182 @ 2 1/2"2231 (3.50")Passed (8%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)166 @ 9"1238 Passed (13%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)741 @ 8' 6 1/2"1060 Passed (70%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.696 @ 8' 6 1/2"0.833 Passed (L/287)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)1.113 @ 8' 6 1/2"1.111 Passed (L/180)--1.0 D + 1.0 Lr (All Spans) Member Length : 17' 1" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 0/12 •Deflection criteria: LL (L/240) and TL (L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •A 15% increase in the moment capacity has been added to account for repetitive member usage. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Stud wall - SPF 3.50"3.50"1.50"68 114 182 Blocking 2 - Stud wall - SPF 3.50"3.50"1.50"68 114 182 Blocking •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)9' 10" o/c Bottom Edge (Lu)17' 1" o/c Dead Roof Live Vertical Load Location (Side)Spacing (0.90)(1.25)Comments 1 - Uniform (PSF)0 to 17' 1"16"6.0 10.0 Default Load Member Notes 2X6 C.J. @ 16" O.C. (MAX SPAN = 16'-6") Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by AP DESIGN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level , C1: 2X6 C.J. @ 16" O.C. 1 piece(s) 2 x 6 DF No.2 @ 16" OC ForteWEB Software Operator Job Notes 7/9/2024 7:20:42 AM UTC Anh Phan AP DESIGN (714) 487-7926 anhtuanxd04@gmail.com ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 File Name: 23190 - 2801 W Elder Ave Page 3 / 8 Page 9 of 22 2801 W Elder Ave & Unit# 24/15/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)363 @ 11' 3 3/4"1406 (1.50")Passed (26%)--1.0 D + 1.0 Lr (Alt Spans) Shear (lbs)289 @ 10' 8 13/16"1631 Passed (18%)1.25 1.0 D + 1.0 Lr (Alt Spans) Moment (Ft-lbs)567 @ 7' 10 15/16"1478 Passed (38%)1.25 1.0 D + 1.0 Lr (Alt Spans) Live Load Defl. (in)0.063 @ 7' 3 7/8"0.435 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Total Load Defl. (in)0.096 @ 7' 4 1/8"0.580 Passed (L/999+)--1.0 D + 1.0 Lr (Alt Spans) Member Length : 11' 11 11/16" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD Member Pitch : 3.54/12 •Deflection criteria: LL (L/240) and TL (L/180). •Overhang deflection criteria: LL (2L/240) and TL (2L/180). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ¹ See Connector grid below for additional information and/or requirements. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Beveled Plate - SPF 3.50"3.50"1.50"141 213 353 Blocking 2 - Hanger on 7 1/4" SPF beam 3.50"Hanger¹1.50"130 233 363 See note ¹ •Maximum allowable bracing intervals based on applied load. •Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)11' 10" o/c Bottom Edge (Lu)11' 10" o/c Connector: Simpson Strong-Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LRU26Z 1.94"N/A 4-10dx1.5 5-10d •Refer to manufacturer notes and instructions for proper installation and use of all connectors. • Side loads are assumed to not induce cross-grain tension. Dead Roof Live Vertical Loads Location (Side)Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 11' 3 3/4"N/A 2.8 -- 1 - Tapered (PLF)0 to 2' 9 15/16"N/A 0.0 to 32.3 0.0 to 56.6 Generated from Roof Geometry 2 - Tapered (PLF)2' 9 15/16" to 11' 3 3/4"N/A 0.0 to 43.1 0.0 to 84.9 Generated from Roof Geometry Member Notes HIP BEAM AT BED #1 Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level , BM1: HIP BEAM AT BED #1 1 piece(s) 2 x 8 DF No.2 ForteWEB Software Operator Job Notes 7/9/2024 7:20:42 AM UTC Anh Phan AP DESIGN (714) 487-7926 anhtuanxd04@gmail.com ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 File Name: 23190 - 2801 W Elder Ave Page 4 / 8 Page 10 of 22 2801 W Elder Ave & Unit# 24/15/2025 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by AP DESIGN Weyerhaeuser Notes ForteWEB Software Operator Job Notes 7/9/2024 7:20:42 AM UTC Anh Phan AP DESIGN (714) 487-7926 anhtuanxd04@gmail.com ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 File Name: 23190 - 2801 W Elder Ave Page 5 / 8 Page 11 of 22 2801 W Elder Ave & Unit# 24/15/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1188 @ 0 3281 (1.50")Passed (36%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1009 @ 10 3/4"4856 Passed (21%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)3534 @ 5' 11 7/16"5615 Passed (63%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.139 @ 6' 2 5/8"0.433 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.269 @ 6' 2 5/16"0.650 Passed (L/581)--1.0 D + 1.0 Lr (All Spans) Member Length : 13' System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"600 587 1188 None 2 - Trimmer - SPF 1.50"1.50"1.50"303 319 622 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)13' o/c Bottom Edge (Lu)13' o/c Dead Roof Live Vertical Loads Location Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 13'N/A 8.2 -- 1 - Uniform (PSF)0 to 13'1' 4"6.0 10.0 Default Load 2 - Point (lb)6' 3"N/A 130 233 3 - Uniform (PSF)0 to 6' 3"2'15.0 - 4 - Uniform (PSF)0 to 6' 3"4'15.0 20.0 Member Notes BEAM AT BED #1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by AP DESIGN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level , BM2: BEAM AT BED #1 1 piece(s) 4 x 10 DF No.2 ForteWEB Software Operator Job Notes 7/9/2024 7:20:42 AM UTC Anh Phan AP DESIGN (714) 487-7926 anhtuanxd04@gmail.com ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 File Name: 23190 - 2801 W Elder Ave Page 6 / 8 Page 12 of 22 2801 W Elder Ave & Unit# 24/15/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1075 @ 10' 9"3281 (1.50")Passed (33%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)955 @ 10' 1/4"3806 Passed (25%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)2786 @ 6'3737 Passed (75%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.158 @ 5' 7 3/16"0.358 Passed (L/817)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.297 @ 5' 7 5/16"0.313 Passed (L/435)--1.0 D + 1.0 Lr (All Spans) Member Length : 10' 9" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (5/16"). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"294 330 624 None 2 - Trimmer - SPF 1.50"1.50"1.50"525 550 1075 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)10' 9" o/c Bottom Edge (Lu)10' 9" o/c Dead Roof Live Vertical Loads Location Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 10' 9"N/A 6.4 -- 1 - Uniform (PSF)0 to 10' 9"1' 4"15.0 20.0 Default Load 2 - Point (lb)6'N/A 130 233 3 - Uniform (PSF)6' to 10' 6"2'15.0 - 4 - Uniform (PSF)6' to 10' 6"4'15.0 20.0 Member Notes BEAM AT LIVING Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by AP DESIGN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level , BM3: BEAM AT LIVING 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 7/9/2024 7:20:42 AM UTC Anh Phan AP DESIGN (714) 487-7926 anhtuanxd04@gmail.com ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 File Name: 23190 - 2801 W Elder Ave Page 7 / 8 Page 13 of 22 2801 W Elder Ave & Unit# 24/15/2025 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (lbs)1581 @ 5' 6"3281 (1.50")Passed (48%)--1.0 D + 1.0 Lr (All Spans) Shear (lbs)1260 @ 4' 9 1/4"3806 Passed (33%)1.25 1.0 D + 1.0 Lr (All Spans) Moment (Ft-lbs)2441 @ 3' 3"3737 Passed (65%)1.25 1.0 D + 1.0 Lr (All Spans) Live Load Defl. (in)0.038 @ 2' 9 5/16"0.183 Passed (L/999+)--1.0 D + 1.0 Lr (All Spans) Total Load Defl. (in)0.071 @ 2' 9 3/8"0.275 Passed (L/928)--1.0 D + 1.0 Lr (All Spans) Member Length : 5' 6" System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2021 Design Methodology : ASD •Deflection criteria: LL (L/360) and TL (L/240). •Allowed moment does not reflect the adjustment for the beam stability factor. •Applicable calculations are based on NDS. Bearing Length Loads to Supports (lbs) Supports Total Available Required Dead Roof Live Factored Accessories 1 - Trimmer - SPF 1.50"1.50"1.50"678 790 1468 None 2 - Trimmer - SPF 1.50"1.50"1.50"733 849 1581 None •Maximum allowable bracing intervals based on applied load. Lateral Bracing Bracing Intervals Comments Top Edge (Lu)5' 6" o/c Bottom Edge (Lu)5' 6" o/c Dead Roof Live Vertical Loads Location Tributary Width (0.90)(1.25)Comments 0 - Self Weight (PLF)0 to 5' 6"N/A 6.4 -- 1 - Uniform (PSF)0 to 5' 6"12'16.2 20.0 Default Load 2 - Point (lb)3' 3"N/A 303 319 Member Notes HEADER AT BED #1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ document-library. The product application, input design loads, dimensions and support information have been provided by AP DESIGN Weyerhaeuser Notes Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). MEMBER REPORT PASSED Level , BM4: HEADER AT BED #1 1 piece(s) 4 x 8 DF No.2 ForteWEB Software Operator Job Notes 7/9/2024 7:20:42 AM UTC Anh Phan AP DESIGN (714) 487-7926 anhtuanxd04@gmail.com ForteWEB v3.8, Engine: V8.4.1.22, Data: V8.1.6.2 File Name: 23190 - 2801 W Elder Ave Page 8 / 8 Page 14 of 22 2801 W Elder Ave & Unit# 24/15/2025 Page 15 of 22 2801 W Elder Ave & Unit# 24/15/2025 WIND LOAD (ASCE 7-16 MWFRS) Analysis Method Analytic Directional Procedure Basic Wind Speed (ultimate) 95.00 MPH Topography Factor Kzt =1.00 Directionality Factor Kd =0.85 Gust Effect Factor G = 0.85 Internal Pressure Coefficients (GCpi) =0.18 -0.18 Roof Pitch 5.00 :12 22.62 DEG Roof Eve Height 9.000 ft Peak Roof Height 14.750 ft Mean Roof Height 11.875 ft Terrain Exp. Category C Building Length, Parallel to wind direction, L= 33.33 ft L/B = 1.39 Builing Width, Perpendicular to wind direction, B = 24 ft h/L = 0.36 Elevation Ht. 60.48 ft Ke =1.00 α = 9.5 zg = 900 Velocity Pressures q z =.00256K z K zt K K e V Height (ft)Kz Kzt Kd Ke V (MPH)qz 9.00 0.849 1.00 0.85 1.00 95.00 16.63 11.88 0.849 1.00 0.85 1.00 95.00 16.63 11.875 0.849 1.00 0.85 1.00 95.00 16.63 0.849 1.00 0.85 1.00 95.00 16.63 0.849 1.00 0.85 1.00 95.00 16.63 0.849 1.00 0.85 1.00 95.00 16.63 Design Pressures p = qGC p - q h (GC pi ) Note: Pressures are limit state design pressures for strength design. Multiple by 0.6 for ASD. Transverse Direction: z (ft)qz (psf) Cp qGCp (+GCpi) (-GCpi) 11.88 16.63 0.80 11.31 8.32 14.31 0.00 16.63 0.80 11.31 8.32 14.31 0.00 16.63 0.80 11.31 8.32 14.31 0.00 16.63 0.80 11.31 8.32 14.31 11.88 16.63 -0.42 -5.97 -8.96 -2.98 Windward Roof (Positive)11.88 16.63 0.19 2.68 -0.31 5.68 Windward Roof (Negative)11.88 16.63 -0.29 -4.10 -7.10 -1.11 11.88 16.63 -0.60 -8.48 -11.48 -5.49 -11.16 -11.16 8.00 Longitudinal Direction: z (ft)qz (psf) Cp qGCp (+GCpi) (-GCpi) 11.88 16.63 0.80 11.31 8.32 14.31 0.00 16.63 0.80 11.31 8.32 14.31 0.00 16.63 0.80 11.31 8.32 14.31 0.00 16.63 0.80 11.31 8.32 14.31 11.88 16.63 -0.50 -7.07 -10.06 -4.08 Windward Roof (Positive)11.88 16.63 0.11 1.53 -1.47 4.52 Windward Roof (Negative)11.88 16.63 -0.35 -4.89 -7.88 -1.89 11.88 16.63 -0.60 -8.48 -11.48 -5.49 -10.01 -10.01 8.00 Longitudinal Transverse 1 11.875 2.875 9.00 106 103 Windward Wall Leeward Wall Leeward Roof Total Roof load, pr = MIN (SIN* pr , 8) = Level Height Height Above Below Wind Load (plf) Windward Wall Leeward Wall Leeward Roof Total Roof load, pr = MIN (SIN* pr , 8) = Page 16 of 22 2801 W Elder Ave & Unit# 24/15/2025 SEISMIC LOAD ASCE 7-16 Risk Category II Importance Factor (I) 1.00 Site Class D - Default Seismic Design Category D Response Spectral Acc. (0.2 sec) (Ss) =1.306 Response Spectral Acc. (1.0 sec) (S1) =0.467 Fa =1.200 Fv =1.833 Max. Considered earthquake acc. SMS 1.567 Max. Considered earthquake acc. SM1 0.856 Design spectral acc. At short period S DS 1.045 Design spectral acc. at 1s period SD1 0.571 Response modification coefficient (R) 6.5 System overstrength coefficient (Ω) 2.5 Building period coeficient (CT) =0.02 Building Height (ft) 14.75 (65ft maximum) Building period T=Ta (sec)0.151 Long Period Transition Period (TL) =8 Minimum Cs 0.046 Maximum Cs 0.583 Seismic response coefficient C s 0.161 Adjusted Cs 0.161 Design Base Shear V = 0.161W Page 17 of 22 2801 W Elder Ave & Unit# 24/15/2025 BUILING WEIGHT Section Roof/ Floor Weight: P floor = A*(Q partion + Q floor/roof) Wall Weight Pwall = Qwall * hwall *L perimeter Area (A) = 800 sqft Qwall = 15 psf Q partion = 5 psf hwall = 4.5 ft Q floor/roof = 15 psf Lperimeter = 114.75 ft P floor = 16000 lbs Pwall = 7745.625 lbs Cs =0.161 ta =0.151 Total Weight, W = 23746 lbs k =1.000 V = CsW = 3818 lbs SDS =1.045 Shear Wall Force Linear Forces for Shear Wall hxwx Area Qe (psf) Section hx (ft)wx (lbs)hxwx (ft-lbs)hxwx CvxV 9.0 23,746 213711 1.00 3,818 800 4.77 0.0 0 0 0.00 0 0 0.00 0 0 0.00 0 0.00 0 0 0.00 0 0.00 0 0 0 Page 18 of 22 2801 W Elder Ave & Unit# 24/15/2025 SH E A R L I N E L O A D St o r y S e c t i o n Qe ( p s f ) Lo n g . ( p l f ) T r a n . ( p l f ) 1 A 4. 7 7 1 0 6 1 0 3 0 0 . 0 0 Lo n g i t u d i n a l Se i s m i c W i n d Li n e S e c t i o n Tr i b u t a r y Wi d t h ( f t ) Tr i b u t a r y De p t h Sh e a r L i n e Ab o v e Of f s e t ( f t ) Di s t a n c e t o sh e a r w a l l ( f t ) Se i s m i c ( p s f ) Di a p h r a g m Lo a d ( l b s ) Lo a d f r o m Ab o v e ( f t ) Lo a d o n W a l l (l b s ) To t a l L o a d (l b s ) Wi n d ( p l f ) Di a p h r a g m Lo a d ( l b s ) Lo a d f r o m Ab o v e ( f t ) Lo a d o n W a l l (l b s ) To t a l L o a d (l b s ) L1 A 12 . 0 0 33 . 3 3 4. 7 7 19 0 9 0 0 1 9 0 9 1 0 6 1 2 6 9 0 1 2 6 9 L2 A 12 . 0 0 33 . 3 3 4. 7 7 19 0 9 0 0 1 9 0 9 1 0 6 1 2 6 9 0 0 1 2 6 9 0. 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 Tr a n s v e r s e S Se i s m i c W i n d Li n e S e c t i o n Tr i b u t a r y Wi d t h ( f t ) Tr i b u t a r y De p t h Sh e a r L i n e Ab o v e Of f s e t ( f t ) Di s t a n c e t o sh e a r w a l l ( f t ) Se i s m i c ( p s f ) Di a p h r a g m Lo a d ( l b s ) Lo a d f r o m Ab o v e ( f t ) Lo a d o n W a l l (l b s ) To t a l L o a d (l b s ) Wi n d ( p l f ) Di a p h r a g m Lo a d ( l b s ) Lo a d f r o m Ab o v e ( f t ) Lo a d o n W a l l (l b s ) To t a l L o a d (l b s ) T1 A 16 . 6 7 2 4 . 0 0 4. 7 7 19 0 9 0 0 1 9 0 9 1 0 3 1 7 1 0 0 0 1 7 1 0 T2 A 16 . 6 7 24 . 0 0 4. 7 7 19 0 9 0 0 1 9 0 9 1 0 3 1 7 1 0 0 0 1 7 1 0 0. 0 0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0 Se i s m i c W i n d , L o n g S e i s m i c W i n d , T r a n Li n e l b s l b s L i n e l b s l b s L1 1 9 0 9 1 2 6 9 T 1 1 9 0 9 1 7 1 0 L2 1 9 0 9 1 2 6 9 T 2 1 9 0 9 1 7 1 0 Wi n d L o a d Page 19 of 22 2801 W Elder Ave & Unit# 24/15/2025 SH E A R W A L L Lo n g i t u d i n a l No t e : F o r " S p e c i a l C a s e " , l a t e r a l a n a l y s i s a r e p r o v i d e d o n f o l lo w i n g p a g e s E W LI N E To t a l L e n g t h Sh e a r Sh e a r p e r ft . Sh e a r Sh e a r p e r ft . SD , v (p l f ) Mo d e l # l b s M i n . T h i c k n e s s S t r a p l b s Mi n . Th i c k n e s s L1 8 . 0 0 0 1 9 0 9 2 3 9 1 2 6 9 1 5 9 A 2 0 0 SDS = 1. 6 0 0 HD U 2 3 0 7 5 3 . 5 CS 1 6 1 7 0 5 1 . 5 L2 8 . 0 0 0 1 9 0 9 2 3 9 1 2 6 9 1 5 9 B 3 4 0  = 1. 3 HD U 4 4 5 6 5 3 . 5 CS 1 4 2 4 9 0 3 C 5 1 0 0 = 2. 5 0 HD U 5 5 6 4 5 3 . 5 CM S T 1 6 4 9 9 0 3 D 6 6 5 Cd = 4 HD U 8 5 9 8 0 3 . 5 CM S T 1 4 6 4 7 5 3 . 5 E 8 7 0 H D U 8 6 9 7 0 3 . 5 CM S T 1 2 9 2 1 5 3 . 5 F 1 0 2 0 H D U 8 7 8 7 0 5 . 5 G 1 3 3 0 H D U 1 1 9 5 3 5 5 . 5 HD U 1 1 1 1 1 7 5 7 . 2 5 HD U 1 4 1 4 4 4 5 7 . 2 5 HD 1 2 1 5 4 3 5 9 . 2 5 HD 1 9 1 9 3 6 0 9 . 2 5 b h h / b MIN [ 2b/h , 1 ] Q w Q f d D w = Q w * d * b /2 D f = Q f * h * b /2 E 0.7  E U i = h *  E U i + 1 U n = ( .7  U i + U i + 1 ) - ( 0.6 - .14 S DS )( D w + D f )  W 0.6 n W U i = h *  W U i + 1 U n = .6 U i + U i + 1 - .6 ( D w + D f ) Li n e L e n g t h H e i g h t As p e c t Ra t i o Re d u c t i o n Fa c t o r Wa l l L o a d F l o o r L o a d Tr i b u t a r y De p t h Re s i s t i n g De a d L o a d Wa l l Re s i s t i n g De a d L o a d Fl o o r Sh e a r AS D Sh e a r Up l i f t Up l i f t Fr o m Ab o v e Ne t U p l i f t S h e a r A S D S h e a r U p l i f t Up l i f t Fr o m Ab o v e Ne t U p l i f t S h e a r T y p e Fl o o r T o Fl o o r Fo u n d a t i o n Ho l d D o w n L1 8. 0 0 9 . 0 0 1 . 1 3 1 . 0 0 15 1 5 3 5 4 0 1 8 0 23 9 2 1 7 2 1 4 7 1 6 8 3 1 5 9 9 5 1 4 2 7 4 2 4 B C S 1 6 H D U 2 L2 4. 0 0 9 . 0 0 2 . 2 5 0 . 8 9 15 1 5 3 2 7 0 9 0 23 9 2 1 7 2 1 4 7 1 8 1 9 1 5 9 9 5 1 4 2 7 6 4 0 B C S 1 4 H D U 2 L2 4. 0 0 9 . 0 0 2 . 2 5 0 . 8 9 15 1 5 3 2 7 0 9 0 23 9 2 1 7 2 1 4 7 1 8 1 9 1 5 9 9 5 1 4 2 7 6 4 0 B C S 1 4 H D U 2 Page 20 of 22 2801 W Elder Ave & Unit# 24/15/2025 Tr a n s v e r s e VE VW LI N E To t a l L e n g t h Sh e a r Sh e a r p e r ft . Sh e a r Sh e a r p e r ft . No t e : F o r " S p e c i a l C a s e " , l a t e r a l a n a l y s i s a r e p r o v i d e d o n f o l lo w i n g p a g e s T1 8. 0 0 19 0 9 23 9 17 1 0 21 4 T2 8. 0 0 19 0 9 23 9 17 1 0 21 4 Ma x i m u m c a p a c i t y o f 5 / 8 " S E T - X P w / 5 / 8 " D i a F 1 5 5 4 G r . 3 6 = 2 8 0 0 l b s Se e a t t a c h e d S i m p s o n S t r o n g T i e A n c h o r D e s i g b h h / b MIN [ 2b/h , 1 ] Q w Q f d D w = Q w * d * b /2 D f = Q f * h * b /2 E 0.7  E U i = h *  E U i + 1 U n = ( .7  U i + U i + 1 ) - ( 0.6 - .14 S DS )( D w + D f )  W 0.6 n W U i = h *  W U i + 1 U n = .6 U i + U i + 1 - .6 ( D w + D f ) Li n e L e n g t h H e i g h t As p e c t Ra t i o Re d u c t i o n Fa c t o r Wa l l L o a d F l o o r L o a d Tr i b u t a r y De p t h Re s i s t i n g De a d L o a d Wa l l Re s i s t i n g De a d L o a d Fl o o r Sh e a r AS D Sh e a r Up l i f t Up l i f t Fr o m Ab o v e Ne t U p l i f t S h e a r A S D S h e a r U p l i f t Up l i f t Fr o m Ab o v e Ne t U p l i f t S h e a r T y p e Fl o o r T o Fl o o r Fo u n d a t i o n Ho l d D o w n T1 8 . 0 0 9 . 0 0 1 . 1 3 1 . 0 0 1 5 1 5 3 5 4 0 1 8 0 2 3 9 2 1 7 2 1 4 8 1 6 8 4 2 1 4 1 2 8 1 9 2 4 7 2 3 B C S 1 6 H D U2 T2 8. 0 0 9 . 0 0 1 . 1 3 1 . 0 0 15 1 5 3 5 4 0 1 8 0 23 9 2 1 7 2 1 4 8 1 6 8 4 2 1 4 1 2 8 1 9 2 4 7 2 3 B C S 1 6 H D U 2 Page 21 of 22 2801 W Elder Ave & Unit# 24/15/2025 FOUNDATION: ADDTION 1500 psf Trib Trib Wall Height DL(psf) LL(psf) roof(ft) DL(psf) LL(psf) floor(ft) DL(psf) wall(ft) 15 20 14 15 9 Roof: (DL+LL) (Trib) = 490 plf Floor: (DL+LL) (Trib) = 0 plf Wall: DL (Height)= 135 plf 625 plf 625 /(12"/12) = 625 psf< 1500 psf P(allowable) P(allowable) = 5167.5 # 18 " Allowable soil bearing value: Roof Floor use 12" wide cont. ftg w/ 2-#4 top & bott. Page 22 of 22 2801 W Elder Ave & Unit# 24/15/2025 SANTA ANA CITY COUNCIL Mayor vamezcua@santa-ana.org Mayor Pro Tem, Ward 1 tphan@santa-ana.org Ward 2 bvazquez@santa-ana.org Ward 3 jessielopez@santa-ana.org Ward 4 pbacerra@santa-ana.org Ward 5 jryanhernandez@santa-ana.org Ward 6 dpenaloza@santa-ana.org MAYOR Valerie Amezcua MAYOR PRO TEM Thai Viet Phan COUNCILMEMBERS Phil Bacerra Johnathan Ryan Hernandez Jessie Lopez David Penaloza Benjamin Vazquez CITY OF SANTA ANA PLANNING AND BUILDING AGENCY 20 Civic Center Plaza ● P.O. Box 1988 Santa Ana, California 92702 www.santa-ana.org ACTING CITY MANAGER Alvaro Nuñez CITY ATTORNEY Sonia R. Carvalho CITY CLERK Jennifer L. Hall Also sent via email to: jamesle01051986@gmail.com April 3, 2024 James Le 2801 W. Elder Avenue Santa Ana, CA. 92704 Subject: Address Assignment for a new Accessory Dwelling Unit located at 2801 West Elder Avenue and (APN: 407-043-16) in Santa Ana, CA Dear James, The City of Santa Ana Planning and Building Agency (PBA) is the responsible agency for legal addressing within the City of Santa Ana’s jurisdiction. This letter confirms the address assignment for a new Accessory Dwelling Unit located at 2801 West Elder Avenue and (APN: 407-043-16). Notice is hereby given that the following assigned address(es) shall be posted onsite per the approved address plan, attached hereto as Exhibit A. Address(es) to be Activated/Posted 1. 2801 W. Elder Avenue, Unit 2 (Address for new ADU) To subdivide commercial and/or residential units into multiple units, a building permit (and all other associated permits), plans, and inspection approvals by the PBA are required. Address(es) will be verified during inspections by the Building Safety Division. Please update your records accordingly. Should you have any questions, feel free to contact me by phone at (714) 667-2709 or by email at ASevilla@santa-ana.org. Sincerely, Alexis Sevilla Planning Technician Reviewed by: Jerry Guevara, Senior Planner 2801 W Elder Ave & Unit# 24/15/2025 Address Letter for 2801 W Elder Avenue Page 2 of 2 Exhibit A – Address Plan c: Vencent Quaglia, United States Post Office Chris Tuiolosega, United States Post Office Cipriano Corona, Marketing Manager, United States Post Office Alex Alvarez, Postmaster Santa Ana, United States Post Office Federal Express, Administration Cathy Joseph, Garden Grove Unified School District Christine Hy, Garden Grove Unified School District Cathy Slader, Orange Unified School District Orin Williams, Santa Ana Unified School District Yvette Miranda, Santa Ana Unified School District Cristina Bernal, Tustin Unified School District Orange County Fire Authority Neal Kelly, Registrar of Voters Members, Board of Supervisors Southern California Gas Company Southern California Edison Company Claude Parrish, County Assessor's Office SAG, AT&T UPS, Administration City Manager’s Office Beverly Martin, Police Community Services Specialist Boris Duran, Police Systems Manager Jennifer Mendoza, Police Communications Manager Chris Hubbard, Police Systems Support Analyst Alejandra Gutierrez, Treasury & Customer Services Manager Hector Jimenez, Revenue Supervisor Alfonso Chavez, Utilities Customer Services Supervisor Judson Brown, Housing & Neighborhood Development Manager Rudy Rosas, Principal Civil Engineer Zdenek (Zed) Kekula, Principal Civil Engineer Jason Kwak, Building Safety Manager Evelyn LaRocca, Permit Supervisor Kathy Hernandez, Permit Technician Julie Amsden, Permit Technician Ali Pezeshkpour, Planning Manager Jerry Guevara, Senior Planner Alvaro Nunez, PBA Assistant Director and Code Enforcement Manager 2801 W Elder Ave & Unit# 24/15/2025 (E) 2801 W ELDER AVE (N) 2801 W ELDER AVE UNIT 2 EXHIBIT A - ADDRESS PLAN 2801 W Elder Ave & Unit# 24/15/2025 Planning & Building Agency Building and Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714)-647-5800 www.santa-ana.org DETACHED ADU - GRADING PERMIT EXEMPTION CHECKLIST PCC-16 REV: 09/03/2020 Page 1 of 1 THIS FORM SHALL BE COMPLETED BY A CALIFORNIA REGISTERED CIVIL ENGINEER. Instructions: In order to qualify for the grading permit exemption for detached Accessory Dwelling Unit (ADU) projects per handout PCC-15, the registered civil engineer of record shall complete all sections, check all boxes and sign the certification section below. A copy of this checklist shall be attached to each of TWO sets of plans. If answering NO to any of the questions, a grading permit shall be required. Project Address: Yes No 1. ☐☐ I have provided two sets of site drainage plans that is stamped, signed and dated by a California professional civil engineer, to be submitted with the building submittal package. 2. ☐☐ I have calculated the total amount of soil being cut or filled on this project is less than 50 cubic yards. 3. ☐☐ The site drainage plans include the following, but not limited to, location of all existing and proposed structures, property lines, right-of-way lines, and easements, including dimensions and setbacks; drainage slopes and flow patterns, drainage systems such as swales, french drains, water collection and disposal systems, etc. 4. ☐☐ I have designed drainage such that surface water flows away from buildings and adjoining property lines, in accordance with all applicable codes. 5. ☐☐ I have designed grading such that it will not adversely affect the adjoining properties. 6. ☐ ☐ I have designed the grade to fall not fewer than 6 inches within the first 10 feet from the foundation walls. Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, I have designed drains or swale to ensure drainage away from the structure. I have designed any impervious surfaces within 10 feet of the building foundation to be sloped not less than 2 percent away from the building. 7. ☐☐ I will provide a final certification letter stating that the grades were constructed per the approved site drainage plan, and will submit this certification letter to the building inspector prior to final inspection. I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Licensed Number: Date: Phone Number: Email Address: 1213 S Flower St, Santa Ana, CA 92707 X X X X X X X MICHAEL MALCOLM PHILLIPS C68338 657-444-7194 9/27/2023 mike@phillipsconsulting.us 1314 S JOANE WAY, SANTA ANA, CA 927042801 W ELDER AVE, UNIT 2 (ADU), SANTA ANA, CA 92704 7/4/2024 2801 W Elder Ave & Unit# 24/15/2025 O R A N G E C O U N T Y F I R E A U T H O R I T Y Plan Submittal Criteria Form Required for Single Family or Duplex Residences (Use Commercial form for lots with 3+ dwelling units or new residential tracts) Complete the Project Information and Questionnaire below, then sign and date the Applicant Certification. Project Information  New Single Family Residence/Duplex  Addition/Remodel  ADU  Other Address: Unit #: City or Unincorporated County Area: ZIP: Scope of Work: Existing Area: Area to be Added: Total Resulting Area: Stories: Area Added in Past 2 Years (excluding this project): Yes No Questionnaire OCFA Plan Type if “Yes” 1.   New – Is this a new single family residence or duplex? *(PR160) Residential Site with Water Availability (PR400-402) Fire Sprinkler 2.   ADU – Is this a new Accessory Dwelling Unit (ADU) on the same property as a house that already has fire sprinklers or a house that will have fire sprinklers added as part of this project? (PR400-402) Fire Sprinkler 3.   Addition – Is this (A) an addition to a currently sprinklered building, or (B) an addition requiring a fire sprinkler retrofit based on a threshold set by local ordinance? (PR400-402) Fire Sprinkler 4.   Distance – Is the most remote portion of the addition, ADU or other detached structure greater than 140-feet from the fire access roadway? *(PR160) Residential Site 5.   Total Area – Will the addition result in a total area of greater than 3,600 square feet (sf) for non- sprinklered buildings, or greater than 6,200 sf for sprinklered buildings, including the area of all enclosed spaces, such as garages, stairs, and detached structures separated by less than 10-feet? *(PR160) Residential Site with Water Availability 6.   Remodel – Is this a remodel of a sprinklered building with a scope of work that includes adding or removing any interior walls? Note: If “Yes”, then project must be evaluated by a C-16 licensed contractor to determine if a fire sprinkler modification is needed. (PR400-402) Fire Sprinkler 7.   Detached Structure – Is this a new detached utility or accessory structure (not an ADU), such as a garage, workshop, game room, pool house, barn, etc., requiring fire sprinklers based on a threshold set by local ordinance? *(PR160) Residential Site (PR400-402) Fire Sprinkler 8.   Gate – Is a gate being installed across a driveway or road that is designated as a fire department access roadway, or a driveway or road that serves more than a single home/duplex? (PR180) Gate 9.   Methane – Is project located in or less than 100’ from a “Division of Oil, Gas, and Geothermal Resources” (DOGGR) field boundary or well (active or abandoned), less than 300-feet from an oil/gas seep, or less than 1000-feet from a landfill? (Note: For projects in Yorba Linda, this requirement only applies to new homes, enclosed accessory structures, addition to existing structure greater than 1000 sf, and ADU’s). *(PR160) Residential Site *(PR172-174) Methane Test/Mitigation Plans 10.   Vegetation – Is the property/structure (A) on the perimeter of a community containing, or adjacent to slopes or hills, or (B) adjacent to an open space or wildland area containing non-irrigated vegetation, or (C) in a State Responsibility Area or Local Responsibility Area “Fire Hazard Severity Zone”, as defined by the State, or (D) near an area that could be affected by a wildfire in the open space. *(PR125) Fuel Modification (PR182) Accessory Structure *OCFA approval required before issuance of a grading/building permit. All other plans types may be deferred submittals. Applicant Certification I certify, under penalty of perjury, under the laws of the State of California, that the information above is true: Print Name:_______________________________________ Signature:___________________________________________ Date:______________ Phone Number:_____________________________________________ Email:_____________________________________________________________ Attention Building Department Staff – After you’ve verified all questions were answered accurately as “No”, then you may accept this signed form as a written release that an OCFA review is not required. If any questions were answered as “Yes”, then the plan type on the right side may be required. ______If all answers are “No” and the Building Department still requires the applicant to have their plans reviewed by OCFA, or if any answers are “Yes” and the Building Department prefers for OCFA to determine if a review is required, please initial this line and provide an explanation on the Plan Referral Form (on the reverse), to be submitted along with the appropriate plans to OCFA for a determination. For questions and submittal information, please visit ocfa.org, or call OCFA at (714) 573-6100 SFR 2801 W Elder Ave & Unit# 24/15/2025 2801 W Elder Ave & Unit# 24/15/2025