EXISTING PLANNING & BUILDING TABULATIONS
SCOPE OF WORK
CONVERSION OF EXISTING STORAGE ROOM TO YOUTH ASSEMBLY ROOM (1,445 SF TOTAL AREA) - AS APPROVED UNDER CONDITIONAL USE PERMIT NO. 2022-13:
CONSTRUCTION OF (1) INTERIOR PARTITION & (1) DOOR
MODIFICATION OF EXISTING MECHANICAL & LIGHTING SYSTEMS
PROJECT DIRECTORY
TENANT/CLIENT:
COMPASS BIBLE CHURCH
CONTACT: BOB DUMONT
2909 DAIMLER STREET
SANTA ANA, CA 92705
TEL: (714) 290 - 2593
EMAIL: BOB@COMPASSCHURCH.ORG
OWNER:
DAIMLER COMMERCE PARTNERS, LP
2 TASMAN SEA
NEWPORT COAST, CA 92657
EMAIL: FHUANG39@GMAIL.COM
ARCHITECT/ APPLICANT:
ELEMENTS ARCHITECTURE, INC.
6B LIBERTY, SUITE 100
ALISO VIEJO, CA 92656
CONTACT: SHELLEY MACDONALD
TEL: (714) 917-7244
EMAIL: STHOMPSON@ELEMENTSARCH.COM
PROJECT:COMPASS BIBLE CHURCH - YOUTH ROOM
PROJECT ADDRESS:2909 DAIMLER STREET
SANTA ANA, CA 92705
LEGAL DESCRIPTION:THE LAND REFERRED TO HEREIN BELOW IS
SITUATED IN THE COUNTY OF ORANGE, STATE OF
CALIFORNIA, & IS DESCRIBED AS FOLLOWS:
PARCEL 2, IN THE CITY OF SANTA ANA, COUNTY OF
ORANGE, STATE OF CALIFORNIA, AS SHOWN ON A MAP FILED
IN BOOK 30 PAGE 19 OF PARCEL MAPS, IN THE OFFICE OF
THE COUNTY RECORDER OF ORANGE COUNTY, CALIFORNIA.
EXCEPTIN THEREFROM, ONE-HALF OF ALL OIL, GAS,
MINERALS, HYDROCARBONS & ASSOCIATED SUBSTANCES
LYING BELOW A DEPTH OF 500 FT. FROM THE SURFACE
OF SAID LAND, W/O THE RIGHT OF SURFACE OR
SUBSURFACE ENTRY ABOVE A DEPTH OF 500 FT. FROM
THE SURFACE OF SAID LAND, AS RESERVED IN DEED
RECORDED AUGUST 9, 1968 IN BOOK 8685 PAGE 900
OF OFFICIAL RECORDS OF ORANGE COUNTY.
ACCESSORS PARCEL NO.:430-191 -08
FLOOR AREA RATIO:0.39
ZONING DESIGNATION:PROFESSIONAL (P)
LAND USE DESIGNATION:PROFESSIONAL & ADMINISTRATIVE OFFICE (PAO)
LOT NUMBER(S):LOT 116
LOT AREA:122,099 SF = 2.803 AC. (NO PROPOSED CHANGE)
NUMBER OF STORIES:TWO
CONSTRUCTION TYPE:TYPE III-B
OCCUPANCY CLASSIFICATION:ASSEMBLY (A-3), BUSINESS (B), STORAGE (S-2)
*C.B.C. SEC. 508.3 NON-SEPARATED OCCUPANCIES
ALLOWABLE ACTUAL
BUILDING AREA:28,500 SF 23,538 SF
BUILDING HEIGHT:75 FT.+/-22 FT.
NO. OF STORIES:THREE TWO
ZONING:
REQUIRED PROVIDED
MAX. STRUCTURE HEIGHT:+35 FT.+/-22 FT.
SETBACKS:
FRONT: 15 FT.54.28 FT.
SIDE (STREET ABUTMENT): 15 FT.N/A
SIDE (INT. SIDE PROP. LINES): 5 FT.35.00 FT.
REAR (*): 50 FT.N/A
REAR: 10 FT.44.61 FT.
(*) MAINTAIN SETBACK IF LOT ABUTTING ON REAR PROPERTY LINE IS A PARCEL USED OR ZONED FOR
RESIDENTIAL PURPOSES.
CONSTRUCTION TYPE:III-B, FULLY SPRINKLERED (NFPA 13)
OCCUPANCY CLASSIFICATION:A3, B, S2 (NON-SEPARATED PER CBC 508.3)
EXISTING BUILDING AREAS:
OVERALL BUILDING
GROUND FLOOR
ADJACENT TENANTS (B OCCUPANCY) = 23,888 SF
COMPASS BIBLE CHURCH (A-3 OCCUPANCY) = 19,850 SF
TOTAL 43,738 SF
SECOND FLOOR
COMPASS BIBLE CHURCH (A-3 OCCUPANCY) = 3,688 SF
TOTAL 3,688 SF
TOTAL 47,426 SF
TENANT AREA
GROUND FLOOR
COMPASS BIBLE CHURCH (A-3 OCCUPANCY) = 19,850 SF
SECOND FLOOR
COMPASS BIBLE CHURCH (A-3 OCCUPANCY) = 3,688 SF
TOTAL 23,538 SF
HEIGHT (PER CBC TABLE 504.3): ALLOWABLE ACTUAL
60' *22'-0 (EXISTING)
*USE A OCCUPANCY; MOST RESTRICTIVE
STORIES (PER CBC TABLE 504.4): ALLOWABLE ACTUAL
2*2 (EXISTING)
*USE A-3 OCCUPANCY; MOST RESTRICTIVE
ALLOWABLE AREA (PER CBC TABLE 506.2): ALLOWABLE ACTUAL
24,000 SF**19,850 SF (GROUND)
3,688 SF (SECOND)
48,000 SF **23,538 SF (TOTAL)
**Aa = (At + (NS X If) X Sa
= (18,000 + (6, 000 X 1 ) X 2
= 48,000 (24,000 PER FLOOR)
VICINITY MAPKEY SITE PLAN
PLANNING
BUILDING
ELECTRICAL & MECHANICAL ENGINEER:
MEP ENERGY SOLUTIONS GROUP, INC.
79705 STAR FLOWER TRAIL
LA QUINTA, CA 92253
CONTACT: BENNETT HEALY
TEL: (562) 439 - 2935
EMAIL: BHEALY@MEPESG.COM
ABBREVIATIONS:
GENERAL NOTES
1. THE ARCHITECT WILL BE THE INTERPRETER OF THE REQUIREMENTS OF THE CONSTRUCTION
DOCUMENTS & THE JUDGE OF THE PERFORMANCE THERE UNDER BY BOTH THE OWNER & THE
CONTRACTOR.
2. ALL CONSTRUCTION & MATERIALS SHALL BE AS SPECIFIED & AS REQUIRED BY THE CURRENT
EDITION OF THE C.B.C., & LOCAL CODES & AUTHORITIES.
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & SITE CONDITIONS BEFORE STARTING WORK.
SHOULD A DISCREPANCY APPEAR IN THE SPECIFICATIONS OR DRAWINGS OR IN THE WORK DONE BY
OTHERS FROM THE CONSTRUCTION DOCUMENTS THAT AFFECT ANY WORK, NOTIFY THE ARCHITECT
AT ONCE FOR INSTRUCTION ON HOW TO PROCEED. IF THE CONTRACTOR PROCEEDS WITH THE
WORK KNOWING OF AN ERROR, INCONSISTENCY, OR OMISSION IN THE CONTRACT DOCUMENTS
WITHOUT WRITTEN INSTRUCTIONS FROM THE ARCHITECT, THE CONTRACTOR SHALL MAKE GOOD
ANY RESULTING DAMAGE OR DEFECT TO THE SATISFACTION OF THE ARCHITECT.
4. SHOULD A CONFLICT OCCUR IN OR BETWEEN DRAWINGS & SPECIFICATIONS, THE SPECIFICATIONS
SHOULD TAKE PRECEDENCE, UNLESS A WRITTEN DECISION FROM THE ARCHITECT HAS BEEN
OBTAINED WHICH DESCRIBES A CLARIFICATION OR ALTERNATE METHOD &/OR MATERIALS.
5. THE CONTRACTOR SHALL CONFINE THEIR OPERATIONS ON THE SITE TO AREAS PERMITTED BY THE
OWNER. THE WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LAWS, LOCAL ORDINANCES,
PERMITS & THE CONTRACT DOCUMENTS.
6. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION FREE OF DEBRIS & LITTER, &
SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY MATERIALS OR EQUIPMENT. EACH SUB-
CONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF HIS WORK SHALL REMOVE ALL
TRASH & DEBRIS AS A RESULT OF HIS OPERATIONS.
7. ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED & PROTECTED TO PREVENT
DAMAGE & DETERIORATION UNTIL USE. FAILURE TO PROTECT MATERIALS MAY BE CAUSE
REJECTION OF WORK.
8. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, OR PATCHING OF THEIR WORK THAT MAY BE
REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY & SHALL NOT ENDANGER ANY
WORK BY CUTTING, EXCAVATING, OR OTHERWISE ALTERING THE WORK OR ANY PART OF IT. ALL
PATCHING, REPAIRING & REPLACING OF MATERIALS & SURFACES, CUT OR DAMAGED IN EXECUTION
OF WORK SHALL BE DONE WITH APPLICABLE MATERIALS SO THAT SURFACES REPLACED WILL, UPON
COMPLETION MATCH SURROUNDING SIMILAR SURFACES.
9. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE
COMMENCED UNTIL THE SUBMISSION HAS BEEN APPROVED BY THE ARCHITECT. ALL SUCH
PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH APPROVED SHOP DRAWINGS & SAMPLES.
10. DIMENSIONS:
A. ALL DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALE.
B. ALL DIMENSIONS TO WOOD STUDS ARE TO FACE OF FRAMING, U.O.N.
C. ALL DIMENSIONS TO METAL STUDS ARE TO CENTER OF FRAMING, U.O.N.
D. CEILING HEIGHT DIMENSIONS ARE FROM THE FINISH FLOOR SLAB TO THE FACE OF CEILING
FINISH MATERIAL UNLESS OTHERWISE NOTED.
11. SAMPLES OF ALL COLORS & MATERIALS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW &
APPROVAL PRIOR TO ORDERING OF PRODUCTS OR COMMENCING RELATED WORK.
12. SUBSTITUTIONS OF MATERIALS HAVING LIKE QUALITY TO THOSE SPECIFIED OR NOTED WILL BE
CONSIDERED BY THE ARCHITECT. WHERE DESIGN OR DETAIL MODIFICATIONS ARE REQUIRED TO
INCORPORATE THESE SUBSTITUTIONS, THE CONTRACTOR SHALL PROVIDE ALL DRAWINGS & DATA
TO THE ARCHITECT FOR APPROVAL AS REQUESTED TO VERIFY THE QUALITY & CHARACTER OF THE
PRODUCTS & SHOWING THEIR CORRECT INCORPORATION INTO THE PROJECT. THE CONTRACTOR
SHALL NOT MAKE CHANGES WITHOUT THE PRIOR WRITTEN APPROVAL OF THE ARCHITECT.
13. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO ENSURE ALL SUB-CONTRACTORS HAVE
ACCESS TO ALL OF THE VARIOUS DISCIPLINE DRAWINGS TO ACCOMPLISH THE WORK SPECIFIED IN
THE CONTRACT DOCUMENTS.
14. AT LEAST 50% OF CONSTRUCTION WASTE MATERIALS ARE TO BE RECYCLED.
15. PROVIDE ALL NECESSARY BLOCKING, BACKING & FRAMING FOR LIGHT FIXTURES, ELECTRIC UNITS,
A/C EQUIPMENT & ALL OTHER ITEMS AS REQUIRED.
16. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODE TO ALL CONCEALED SPACES,
VOIDS, ATTICS, ETC. VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION.
17. WHERE LARGER STUDS OR FURRING IS REQUIRED TO COVER PIPING & CONDUITS, THE LARGER
STUD SIZE OR FURRING SHALL EXTEND THE FULL LENGTH OF THE WALL WIDTH & LENGTH WHERE
THE FURRING OCCURS.
18. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE FEES & FOR OBTAINING THE PERMITS FOR THE
MECHANICAL, ELECTRICAL & PLUMBING SYSTEMS. THESE SYSTEMS SHALL MEET THE
REQUIREMENTS OF ALL LOCAL CODES & ORDINANCES, & THE REQUIREMENTS OF ALL CURRENT
STATE & FEDERAL CODES.
19. THE CONTRACTOR SHALL PAY FOR THE MAIN ARCHITECTURAL BUILDING PERMIT. THE CONTRACTOR
WILL BE REIMBURSED BY THE OWNER FOR THE COST OF THIS PERMIT. ALL OTHER PERMIT FEES
SHALL BE PAID BY THE GENERAL CONTRACTOR.
20. THE PROJECT CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO MAINTAIN BUILDING
SAFEGUARDS, EXITS & FIRE PROTECTION DEVICES. PROTECT ADJACENT PROPERTIES, WORKERS,
PEDESTRIANS & OTHER PERSONS DURING EXCAVATION & CONSTRUCTION OPERATIONS.
21. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID
WASTE, PETROLEUM BYPRODUCTS, SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS OR
WASTEWATER GENERATED ON CONSTRUCTION SITES OR BY CONSTRUCTION ACTIVITIES SHALL BE
PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM.
SYMBOLS LEGEND
DETAIL IDENTIFICATION
BUILDING DETAIL:
SHEET WHERE DETAIL LOCATED
BUILDING SECTION:
SECTION IDENTIFICATION
SHEET WHERE SECTION LOCATED
GRID LINE HEAD
DOOR REFERENCE
KEYNOTE REFERENCE
REVISION
?
0
1
A101
SIM
1ROOM NUMBER Room name
101
AA-0 FINISH REFERENCE
WALL TYPE REFERENCE
DETAIL REFERENCE:
DETAIL IDENTIFICATION
SHEET WHERE DETAIL LOCATED
1
A101
?
?
1 A101
# POUND OR NUMBER
@ AT
℄ CENTERLINE
∠ ANGLE
⌀ DIAMETER
---------------------------------------------
A.B. ANCHOR BOLTS
A.D. AREA DRAIN
A/C AIR-CONDITIONING
A.C. ASPHALTIC CONCRETE
A.C.T. ACOUSTIC CEILING TILE
ACCESS. ACCESSIBLE
ACOUS. ACOUSTICAL
ADJ. ADJUSTABLE
AGGR. AGGREGATE
ALUM. ALUMINUM
ALT. ALTERNATE
ANOD. ANODIZED
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
ASPH. ASPHALT
ASS. ASBESTOS
ASSY. ASSEMBLY
---------------------------------------------
B.BASE
B.N.BOUNDARY NAILING
B.O.BOTTOM OF
B.U.BUILT-UP
BD.BOARD
BETW.BETWEEN
BEV.BEVEL
BITUM.BITUMINOUS
BLDG.BUILDING
BLK.BLOCK
BLKG.BLOCKING
BM.BEAM
BOT.BOTTOM
BRG.BEARING
BSMT.BASEMENT
---------------------------------------------
C.B. CATCH BASIN
C.F. CUBIC FOOT
C.G. CORNER GUARD
C.I.P. CAST-IN-PLACE
C.J. CONSTRUCTION JOINT
C.I. CAST IRON
C.M.U. CONCRETE MASONRY UNIT
C.O. CASED OPENING
C.Y. CUBIC YARD
CAB. CABINET
CEM. CEMENT
CER. CERAMIC
CHAM. CHAMFER(ED)
CLG. CEILING
CLKG. CAULKING
CLO. CLOSET
CLR. CLEAR
CNTR. COUNTER
CO. CLEANOUT
COL. COLUMN
CONC. CONCRETE
CONN. CONNECTION
CONSTR. CONSTRUCTION
CONT. CONTINUOUS
CORR. CORRIDOR
CPT. CARPET
CSMT. CASEMENT
CT. CERAMIC TILE
CTR. CENTER
CTSK. COUNTERSUNK
---------------------------------------------
D.F.DRINKING FOUNTAIN
D.H.DOUBLE HUNG
D.L.DEAD LOAD
D.S.P.DRY STANDPIPE
DBL.DOUBLE
DEMO.DEMOLITION
DEP.DEPRESS(ED)
DEPT.DEPARTMENT
DIA.DIAMETER
DIM.DIMENSION
DISP.DISPENSER
DIAG.DIAGONAL
DN.DOWN
DR.DOOR
DS.DOWNSPOUT
DTL.DETAIL
DWG.DRAWING
DWR.DRAWER
---------------------------------------------
E.EAST
E.B.EXPANSION BOLT
E.F.EACH FACE
E.J.EXPANSION JOINT
E.P.ELECTRICAL PANELBOARD
E.W.C.ELECTRICAL WATER COOLER
EA.EACH
ELAST.ELASTOMERIC
ELECT.ELECTRICAL
ELEV.ELEVATION
EMER.EMERGENCY
ENCL.ENCLOSURE
EQ.EQUAL
EQUIP.EQUIPMENT
EQUIV.EQUIVALENT
ESMT.EASEMENT
(E)EXISTING
EXIST.EXISTING
EXP.EXPANSION
EXPO.EXPOSED
EXT.EXTERIOR
---------------------------------------------
F.A.FIRE ALARM
F.D.FLOOR DRAIN
F.E.FIRE EXTINGUISHER
F.E.C.FIRE EXTINGUISHER CABINET
F.F.FINISH FLOOR
F.H.FIRE HYDRANT
F.H.C.FIRE HOSE CABINET
F.N.FIELD NAILING
F.O.FACE OF
F.O.C.FACE OF CONCRETE
F.O.F.FACE OF FINISH
F.O.M.FACE OF MASONRY
F.O.S.FACE OF STUD
FAB.FABRICATE(D)(ION)
FDN.FOUNDATION
(FF)FACTORY FINISH
--------------------------------------------
FGL.FIBERGLASS
FIN. OR F.FINISH
FLASH.FLASHING
FLR.FLOOR
FLUOR.FLUORESCENT
FPRF.FIREPROOF
FT.FOOT OR FEET
FTG.FOOTING
FURN.FURNITURE
FURR.FURRING
FUT.FUTURE
FXTR.FIXTURE
--------------------------------------------
G.B. GRAB BAR
G.C. GENERAL CONTRACTOR
G.I. GALVANIZED IRON
GA. GAUGE
GALV. GALVANIZED
GENL. GENERAL
GL. GLASS
GLB. GLUED LAMINATED BEAM
GND. GROUND
GR. GRADE
GRVL. GRVL.
GT. GROUT
GUT. GUTTER
GYP. GYPSUM
GYP.BD. GYPSUM BOARD
GYP.PLAS. GYPSUM PLASTER
---------------------------------------------
H.B.HOSE BIBB
H.M.HOLLOW METAL
H.V.A.C.HEATING/VENTILATING/AIR-CONDITIONING
H.C.HOLLOW CORE
HDR.HEADER
HDWD.HARDWOOD
HDWR.HARDWARE
HGR.HANGER
HGT.HEIGHT
HORIZ.HORIZONTAL
HP.LAM.HIGH-PRESSURE LAMINATE
HR.HOUR
HTR.HEATER
HYD.HYDRANT
HYDR.HYDRAULIC
---------------------------------------------
I.D.INSIDE DIAMETER (DIM.)
IN.INCHES
INCAN.INCANDESCENT
INCL.INCLUDE(D)(ING)
INFO.INFORMATION
INSP.INSPECT(ING)(ION)
INSTL.INSTALL(ATION)
INSUL.INSULATION
INT.INTERIOR
---------------------------------------------
JAN.JANITOR
JST.JOIST
JT.JOINT
---------------------------------------------
K.D.KILN DRIED
KIT.KITCHEN
---------------------------------------------
L.F.LINEAR FOOT
L.H.LEFT-HAND
L.L.LIVE LOAD
L.V.T.LUXURY VINYL TILE
LAB.LABORATORY
LAM.LAMINATE
LAV.LAVATORY
LB.POUND
LBS.POUNDS
LDGR.LEDGER
LIN.LINEAR
LKR.LOCKER
LOC.LOCATION
LT.LIGHT
LT.WT.LIGHT-WEIGHT
LTG.LIGHTING
--------------------------------------------
M.B.MACHINE BOLT
M.C.MEDICINE CABINET
MAS.MASONRY
MATL.MATERIAL
MAX.MAXIMUM
MECH.MECHANICAL
MED.MEDIUM
MEMB.MEMBRANE
MEZZ.MEZZANINE
MFR.MANUFACTURER
MH.MANHOLE
MIN.MINIMUM
MIR.MIRROR
MISC.MISCELLANEOUS
MLWK.MILLWORK
MTD.MOUNTED
MTG.MOUNTING
MTL.METAL
MTR.MORTAR
MUL.MULLION
--------------------------------------------
(N)NEW
N.NORTH
N.A.NOT APPLICABLE
N.I.C.NOT IN CONTRACT
N.T.S.NOT TO SCALE
NO.NUMBER
NOM.NOMINAL
--------------------------------------------
O.A.OVERALL
O.C.ON CENTER
O.D.OUTSIDE DIAMETER
O/OVER
OBS.OBSCURE
OCC.OCCUPANTS
OFC.OFFICE
OPNG.OPENING
OPP.OPPOSITE
OVHD.OVERHEAD
---------------------------------------------
P.LAM. PLASTIC LAMINATE
P.G. PAINT GRADE
P.T. PRESSURE TREATED
PAR. PARALLEL
PARTN. PARTITION
PCF. POUNDS PER CUBIC FOOT
PEMB. PRE-ENGINEERED METAL BUILDING
PERF. PERFORATE
PERP. PERPENDICULAR
PLAS. PLASTIC
PLUMB. PLUMBING
PLF. POUNDS PER LINEAL FOOT
PLYWD. PLYWOOD
PNL. PANEL
PNT. PAINT
PR. PAIR
PRCST. PRECAST
PREFAB. PREFABRICATE(D)
PREFIN. PREFINISH(ED)
PROP. PROPERTY
PSI. POUNDS PER SQUARE INCH
PT. POINT
PTN. PARTITION
PVC. POLYVINYLCHLORIDE
PVMT. PAVEMENT
-------------------------------------------
Q.T.QUARRY TILE
QTY.QUANTITY
QUAL.QUALITY
---------------------------------------------
R.RISER
R.D.ROOF DRAIN
R.H.RIGHT-HAND
R.O.ROUGH OPENING
R.W.L.RAIN WATER LEADER
RAD.RADIUS
RBR.RUBBER
REC.RECESSED
REF.REFERENCE
REFR.REFRIGERATOR
REINF.REINFORCE(D)
REQ.REQUIRED
RESIL.RESILIENT
REV.REVISE OR REVISION
RFG.ROOFING
RGTR.REGISTER
RLG.RAILING
RM.ROOM
RND.ROUND
---------------------------------------------
S. SOUTH
S.C. SOLID CORE
S.C.W. SOLID CORE WOOD
S.S. STAINLESS STEEL
S.SK. SERVICE SINK
SCHED. SCHEDULE
SECT. SECTION
SH. SHELF
SHR. SHOWER
SHT. SHEET
SIM. SIMILAR
SPEC. SPECIFICATION
SQ. SQUARE
ST. STAIN
STA. STATION
STAG. STAGGER(ED)
STD. STANDARD
STL. STEEL
STOR. STORAGE
STRUCT. STRUCTURAL
SUSP. SUSPENDED
SYM. SYMMETRICAL
SYS. SYSTEM
---------------------------------------------
T&B TOP & BOTTOM
T&G TONGUE & GROOVE
T.TEMPERED
T.O.TOP OF
T.O.C.TOP OF CURB
T.O.P.TOP OF PARAPET
T.O.PL.TOP OF PLATE
T.O.R.TOP OF ROOF
T.O.S.TOP OF SLAB
T.P.TOP OF PAVEMENT
T.S.TUBE STEEL
T.V.TELEVISION
T.W.TOP OF WALL
TEL.TELEPHONE
TEMP.TEMPORARY
TER.TERRAZZO
THK.THICK
THRD.THREAD(ED)
THRES.THRESHOLD
TI.TILE
TR.TREAD
TYP.TYPICAL
---------------------------------------------
U.O.N.UNLESS OTHERWISE NOTED
UNF.UNFINISHED
UR.URINAL
UTIL.UTILITY
---------------------------------------------
V.VINYL
V.C.T.VINYL COMPOSITION TILE
V.I.F.VERIFY IN FIELD
V.P.VINYL PLANK
V.S.VINYL SHEET
VERT.VERTICAL
VEST.VESTIBULE
VNR.VENEER
-------------------------------------------
W/WITH
W/O WITHOUT
W.WEST
W.C.WATER CLOSET
W.GL.WIRE GLASS
W.I.WROUGHT IRON
W.V.WOOD VENEER
W.W.F.WELDED WIRE FABRIC
WD.WOOD
WDW.WINDOW
WF.WIDE FLANGE
W.P.WATERPROOF(ING)
WSCT.WAINSCOT
WT.WEIGHT
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
F
APPLICABLE CODES & STANDARDS
2022 CALIFORNIA BUILDING CODE (CBC), PART 2, CBSC
2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, CBSC
2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, CBSC
2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, CBSC
2022 CALIFORNIA ENERGY CODE, PART 6, CBSC
2022 CALIFORNIA FIRE CODE (CFC)
2022 CALIFORNIA GREEN BUILDING STANDARDS CODE
2022 BUILDING ENERGY EFFICIENCY STANDARDS CODE
SANTA ANA MUNICIPAL CODE (SAMC)
LIST OF FEDERAL CODES & STANDARDS
AMERICANS WITH DISABILITIES ACT (ADA), TITLE II OR TITLE III
FOR TITLE II: UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS)
OR ADA STANDARDS FOR ACCESSIBLE DESIGN (APPENDIX A OF 28 CFR PART 36)
FOR TITLE III: ADA STANDARDS FOR ACCESSIBLE DESIGN (APPENDIX A OF 28 CFR PAR 36)
DEFERRED SUBMITTALS
THIS PROJECT HAS BEEN PERMITTED WITHOUT REVIEW &/OR APPROVAL OF THE FOLLOWING
DEFERRED SUBMITTALS. PLANS APPROVED BY THE CITY SHALL BE OBTAINED FOR EACH DEFERRED
ITEM LISTED BELOW PRIOR TO COMMENCING ANY WORK W/IN THE SCOPE OF SUCH DEFERRAL.
DEFERRALS MUST BE REVIEWED & ACCEPTED BY THE ARCHITECT OR ENGINEER OF RECORD PRIOR TO
SUBMITTING FOR REVIEW W/ THE CITY:
1. MODIFICATIONS TO EXISTING FIRE ALARM SYSTEM (IF / AS REQUIRED)
2. MODIFICATIONS TO EXISTING FIRE SPRINKLER SYSTEM (IF / AS REQUIRED)
FULLY "BUILT-OUT" APPROVED PLAN PER CONDITIONAL USE PERMIT NO. 2022-13
EXISTING/CURRENT PLAN, AS PERMITTED & CONSTRUCTED UNDER #101109480
PROPOSED SCOPE OF WORK UNDER THIS PERMIT
YOUTH
ASSEMBLY
ADJACENT TENANT (NOT IN SCOPE)
ADJACENT TENANT (NOT IN SCOPE)
STORAGE
STORAGE
E DYER RD.
W MACARTHUR BLVD.
E D
Y
E
R RD.
E WARNER AVE.
E DE
E
R
A
V
E
.
DA
I
M
L
E
R
S
T
.
PROJECT LOCATION
2915
2909
23,538 SF
2-STORY
A-3 OCCUPANCY
COMPASS CHURCH
11,944 SF
1 -STORY
B OCCUPANCY
WATER TECHNIQUES
2917
11,944 SF
1 -STORY
B OCCUPANCY
PRIMEGEN BIOTECH
EXISTING 3-HOUR FIRE WALL
DAIMLER STREET
AL
T
O
N
A
V
E
N
U
E
3009 3001 2921
2915-2917
29012909
PCM IRVINE
CHEERLEADING
WATER TECHNIQUES,
PRIMEGEN BIOTECHREGAL
TECHNOLOGY
PARTNERS
NKMAX
BIOTECH
HGST "A WESTERN
DIGITAL CO."
NORTH
A1.1
1
AREA OF WORK
COMPASS
BIBLE
CHURCH
PROJECT
NORTH
TRUE
NORTH
(E) STAIR
ADJACENT TENANT (NOT IN SCOPE)
EXISTING AREA TO REMAIN
NEW INTERIOR PARTITION & DOOR
EXISTING STORAGE ROOM TO BE
CONVERTED TO YOUTH ASSEMBLY
YOUTH ASSEMBLYNEW CURTAIN
STORAGE
M. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECTM. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECT
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
PROJECT NUMBER:
All ideas, designs and plans indicated or represented
by these drawings are owned by and are the property
of Elements Architecture, Inc. and were created and
developed for use in connection with the specified
project. None of such ideas, designs, or plans shall
be used for any purpose whatsoever without the
written permission of Elements Architecture.
Elements Architecture, Inc.
PROJECT NAME:
NO. DESCRIPTION DATE
M. Steven Camp, AIA
Scott Holland, AIA
PROJECT ADDRESS:
SHELLEY MACDONALD
EA
SHELLEY MACDONALD
1
/
9
/
2
0
2
5
8
:
2
2
:
0
6
A
M
21.105
TENANT
IMPROVEMENT
(YOUTH ROOM)
2909 DAIMLER STREET
SANTA ANA, CA 92705
G0.0
COVERSHEET
COMPASS BIBLE CHURCH,
TUSTIN SANTA ANA
SHEET INDEX
SHEET NO. DESCRIPTION
ARCHITECTURAL
A0.1 CODE ANALYSIS & EGRESS PLAN
A1.1 EXISTING SITE PLAN (FOR REFERENCE ONLY)
A2.1 PROPOSED GROUND FLOOR PLAN
A2.2 EXISTING SECOND FLOOR PLAN (FOR REFERENCE ONLY)
A4.1 PROPOSED GROUND FLOOR REFLECTED CEILING PLAN
A5.1 SECTIONS & DETAILS
ELECTRICAL
E0.1 LEGEND, SCHED., GENERAL NOTES & ABBREVIATIONS
E0.2 DETAILS & SCHEDULES
E0.3 LIGHTING CONTROL DETAILS
E2.1 ELECTRICAL FIRST FLOOR LIGHTING PLAN
E4.1 SINGLE LINE DIAGRAM & PANEL SCHEDULES
E5.1 ELECTRICAL SPECIFICATIONS
E6.1 TITLE 24 CALCULATIONS
MECHANICAL
M0.1 LEGEND, SCHED., GENERAL NOTES & ABBREVIATIONS
M0.2 MECHANICAL DETAILS
M2.1 MECHANICAL FIRST FLOOR PLAN
M3.1 MECHANICAL ROOF PLAN
M4.1 MECHANICAL SPECIFICATIONS
(UNDER SEPARATE PERMIT)
(UNDER SEPARATE PERMIT)
G0.0 COVERSHEET
01 -
00-
06-
05-
Bldg #101122238
APPROVALS:
PLNG - F. Arias
BLDG - W. Lee
POLICE - B. Martin
PUBLIC WORKS - Y. Soto
2909 S Daimler St
4/16/2025
WH
FD
FD
UP UP
UP
UP
UP
FIRE & LIFE SAFETY LEGEND
EXIT SIGN -
CEILING / WALL MOUNTED
DIRECTIONAL EXIT SIGN -
CEILING / WALL MOUNTED
1. PROVIDE FIRE EXTINGUISHERS AS SHOWN IN PLANS (MINIMUM) - FINAL LOCATIONS
TO BE DETERMINED BY FIRE DEPARTMENT INSPECTOR.
2. EXITS, EXIT ACCESS DOORS AND PATHS OF EGRESS TRAVEL THAT IS NOT
IMMEDIATELY VISIBLE TO THE OCCUPANTS SHALL BE MARKED BY AN APPROVED
EXIT SIGN THAT IS READILY VISIBLE FROM ANY DIRECTION OF EGRESS TRAVEL.
EXIT SIGNS SHALLL BE INTERNALLY OR EXTERNALLY ILLUMINATED. (NOTE:
ADDITIONAL EXITS SIGNS MAY BE REQUIRED AT TIME OF FIELD INSPECTION.)
3. EXIT ACCESS SHALL NOT PASS THROUGH A ROOM WHICH CAN BE LOCKED TO
PREVENT EGRESS
4. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. (CBC 1013.3).
5. ELECTRICALLY POWERED EXIT SIGNS SHALL BE LISTED AND LABELED IN
ACCORDANCE WITH UL 924. (CBC SECTION 1013.5.)
6. EMERGENCY POWER SUPPLY TO ILLUMINATE EXIT SIGNS FOR A DURATION OF NOT
LESS THAN 90 MINUTES.
7. IN THE EVENT OF A POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL
SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES, LOBBY, CORRIDOR AND
EXTERIOR DOOR LANDING. THE EMERGENCY POWER SYSTEM SHALL PROVIDE
POWER FOR A DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF
STORAGE BATTERIES, UNIT EQUIPMENT OR AN ON-SITE GENERATOR. INITIAL
ILLUMINATION AVERAGE OF 1 FOOT-CANDLE AND A MINIMUM 0.1 FOOT-CANDLE AT
FLOOR LEVEL (CBC 1008.3.4).
8. ALL TACTILE SIGNAGE SHALL BE MOUNTED AT LATCH SIDE OF DOOR.
TACTILE EXIT SIGN, SEE
NUMBER OF OCCUPANTS EXITING SPACE
.... .EXIT
EXISTING WALL-MOUNTED FIRE-EXTINGUISHER,
RATED 2-A/10B/C
10
INDICATES PANIC HARDWARE AT DOORPANIC
FE
MAX OCCUPANCY SIGN, SEE OCC
ASSISTIVE LISTENING SYSTEM SIGN, SEE ALS
ASSISTIVE LISTENING SYSTEM NOTES
1. PROVIDE ASSISTIVE LISTENING SYSTEM AT ASSEMBLY AREAS, CONFERENCE AND MEETING
ROOMS IN ACCORDANCE WITH CBC SECTION 11B-219 AND 11B-706
2. TOTAL NUMBER OF RECEIVERS SHALL BE EQUAL TO 4% TOTAL NUMBER OF SEATS, BUT NO
LESS THAN 2
3. 25% OF MINIMUM RECEIVERS PROVIDED, BUT NO LESS THAN TWO, SHALL BE HEARING-AID
COMPATIBLE PER 11B-219.3
4. AREAS WITH SYSTEM SHALL BE WITHIN 50' VIEWING DISTANCE OF STAGE OR PLAYING AREA
AND HAVE COMPLETE VIEW OF STAGE OR PLAYING AREA, WHERE APPLICABLE.
5. RECEIVERS REQUIRED FOR USE WITH AN ASSISTIVE LISTENING SYSTEM SHALL INCLUDE 1/8"
STANDARD MONO JACK
6. RECEIVERS REQUIRED TO BE HEARING-AID COMPATIBLE SHALL INTERFACE WITH TELECOILS
IN HEARING AIDS THROUGH THE PROVISION OF NECKLOOPS
7. ASSISTIVE LISTENING SYSTEMS SHALL BE CAPABLE OR PROVIDING A SOUND PRESSURE
LEVEL OF 110 dB MINIMUM AND 118 dB MAXIMUM WITH A DYNAMIC RANGE ON THE VOLUME
CONTROL OF 50 dB.
8. THE SIGNAL-TO-NOISE RATIO FOR INTERNALLY GENERATED NOISE IN ASSISTIVE LISTENING
SYSTEMS SHALL BE 18dB MINIMUM
9. PEAK CLIPPING SHALL NOT EXCEED 18 dB OF CLIPPING RELATIVE TO PEAKS OF SPEECH
FIRE & LIFE SAFETY NOTES
THIS PROJECT CONSISTS OF AN EXISTING ONE-STORY CONCRETE AND WOOD FRAMED STRUCTURE.
BUILDING IS SEPARATED FROM ADJACENT BUILDING BY EXISTING 3-HOUR FIRE WALL -SEE DIAGRAM
BELOW.
THE TENANT SPACE IS EQUIPPED WITH AN EXISTING NFPA 13 AUTOMATIC FIRE SPRINKLER SYSTEM
THROUGHOUT.
CONSTRUCTION TYPE:III-B, FULLY SPRINKLERED (NFPA 13)
OCCUPANCY CLASSIFICATION: A3, B, S2 (NON-SEPARATED PER CBC 508.3)
BUILDING AREA:
TENANT AREA OF WORK
GROUND FLOOR = 19,850 SF
SECOND FLOOR = 3,688 SF
TOTAL 23,538 SF
HEIGHT (PER CBC TABLE 504.3):ALLOWABLE ACTUAL
60' *22'-0 (EXISTING)
*USE A OCCUPANCY; MOST RESTRICTIVE
STORIES (PER CBC TABLE 504.4): ALLOWABLE ACTUAL
2*2 (EXISTING)
*USE A-3 OCCUPANCY; MOST RESTRICTIVE
ALLOWABLE AREA (PER CBC TABLE 506.2):ALLOWABLE ACTUAL
24,000 SF PER FLOOR**19,850 SF (GROUND)
3,688 SF (SECOND)
48,000 SF **23,538 SF (TOTAL)
**Aa = (At + (NS X If) X Sa
=(18,000 + (6, 000 X 1 ) X 2
= 48,000 (24,000 PER FLOOR)
EXISTING BUILDING CODE ANALYSIS
(E)
OFFICE
205 (E)
OFFICE
206
(E)
OFFICE
204
(E)
OFFICE
203
(E)
OFFICE
202
(E)
HALLWAY
201
(E) STOR.
207
3
2
4
3
2
9
25
.... .EXIT
1
VOID
2915 2909
23,538 SF
2-STORY
A-3 OCCUPANCY
(AREA OF WORK)
COMPASS CHURCH
11,944 SF
1-STORY
B OCCUPANCY
WATER TECHNIQUES
2917
11,944 SF
1-STORY
B OCCUPANCY
PRIMEGEN BIOTECH
EXISTING 3-HOUR FIRE WALL
(E) STAIR
ADJACENT TENANT (NOT IN SCOPE)(E) 3-HOUR FIRE WALL(E) 3-HOUR FIRE WALL
NOTES:
• SEE SITE PLAN FOR ASSUMED PROPERTY LINE INFORMATION
• EXISTING EXTERIOR WALLS ARE 8" THICK CONCRETE TILT-UP, WHICH HAVE A FIRE-RESISTANCE RATING OF 4 HOURS PER CBC TABLE 721(2)
• FIRE WALL EXTENDS 18" PAST EXTERIOR SURFACE OF EXTERIOR WALL PER CBC 706.5 (EAST SIDE)
• FIRE WALL PERMITTED TO TERMINATE AT INTERIOR SURFACE OF EXTERIOR WALL (WEST SIDE), PROVIDED EXTERIOR WALL HAS A 1-HOUR MIN. FIRE-
RESISTANCE RATING FOR A HORIZONTAL DISTANCE OF NOT LESS THAN 4 FEET, WITH NO OPENINGS -PER CBC 706.5 EXCEPTION 1
• FIRE-RESISTANCE RATING OF ADJACENT EXTERIOR WALLS IS 1-HOUR MIN.; WITH NO OPENINGS, FOR A MINIMUM OF 4 FEET FROM THE INTERSECTION
OF THE FIRE WALL TO EXTERIOR WALL (AS REQUIRED BY CBC 706.5.1 #1)
(E)
OFFICE
109
(E)
NURSERY
107
(E) VOID
108
(E)
MEETING
ROOM
106
(E)
MEETING
ROOM
105
(E) I.T.
ROOM
110
(E)
MEETING
ROOM
111
(E)
MEETING
ROOM
112
(E)
LUNCH
ROOM
113
(E)
MEETING
ROOM
104
(E) F.R.
104A
(E)
MEETING
ROOM
103
(E)
HALLWAY
102
(E)
LOBBY
118
(E)
MEETING
ROOM
114
(E) JAN
115
(E) MEN
116
(E)
WOMEN
117
(E)
AUDITORIUM
119
(E)
STORAGE
120
(E)
STORAGE
121
YOUTH
ROOM
123
(E)
ELECT.
124
(E)
LOBBY
101
(E) STAIR
41
23
16
19
18 19
3
2
18
18
2
20
606
5
1
5
103
104
367
87
173 173
297 149 297
EXIT WIDTH RQ'D = 297 X 0.2 = 59.4"
EXIT WIDTH PROVIDED = 72"
EXIT WIDTH RQ'D = 149 X 0.2 = 29.8"
EXIT WIDTH PROVIDED = 36"
301
153
EXIT WIDTH RQ'D = 153 X 0.2 = 30.6"
EXIT WIDTH PROVIDED = 36"
EXIT WIDTH RQ'D = 301 X 0.2 =60.2"
EXIT WIDTH PROVIDED = 72"
25
NOTE: DESIGN PROPOSES MULTIPLE EXITS WITH NO SINGLE WELL-DEFINED “MAIN EXIT”.
THEREFORE, EXITS HAVE BEEN DISTRIBUTED AROUND THE PERIMETER OF THE BUILDING AS
SHOWN, TO MEET REQUIREMENTS PER CBC 1029.2.
FE
FE
FE
FE
FE
PANIC
PANIC
PANIC PANIC PANIC
PANIC PANIC
PANIC
EXISTING 3-HOUR FIRE WALL
OVERALL BUILDING DIAGONAL = 216'-0"
OVERALL BUILDING EXIT SEPARATION = 121'-10" > 1/3 (216'-0")
AUDITORIUM DIAGONAL = 82'-8"
AUDITORIUM EXIT SEPARATION = 51'-8" > 1/3 (82'-8")
PANIC
174
NOTE: STORAGE ROOM DOES NOT
CONTAIN ANY STORAGE ITEMS TALLER
THAN 6 FEET, AND NO CHEMICALS WILL BE
STORED OR USED WITHOUT PROPER
PERMISSION FROM OCFA.
207
EXIT WIDTH RQ'D = 104 X 0.2 = 20.8"
EXIT WIDTH PROVIDED = 36"
OVERALL DIAGONAL = 57'-2"
EXIT SEPARATION =
43'-3" > 1/3 (57'-2")
EXIT WIDTH RQ'D = 103 X 0.2 = 20.6"
EXIT WIDTH PROVIDED = 36"
PANIC
PANIC
.... .EXIT (E)
(E)
.... .EXIT
OCC
ALS
(N)
(N)
(N)
(N)
(E)
(E)
11
A5.1
12
A5.1
13
A5.1
M. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECTM. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECT
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
PROJECT NUMBER:
All ideas, designs and plans indicated or represented
by these drawings are owned by and are the property
of Elements Architecture, Inc. and were created and
developed for use in connection with the specified
project. None of such ideas, designs, or plans shall
be used for any purpose whatsoever without the
written permission of Elements Architecture.
Elements Architecture, Inc.
PROJECT NAME:
NO.DESCRIPTION DATE
M. Steven Camp, AIA
Scott Holland, AIA
PROJECT ADDRESS:
SHELLEY MACDONALD
EA
SHELLEY MACDONALD
1/
9
/
2
0
2
5
8
:
2
2
:
1
4
A
M
21.105
TENANT
IMPROVEMENT
(YOUTH ROOM)
2909 DAIMLER STREET
SANTA ANA, CA 92705
A0.1
CODE ANALYSIS &
EGRESS PLAN
COMPASS BIBLE CHURCH,
TUSTIN SANTA ANA
BUILDING OCCUPANT LOAD CALCULATIONS AND EGRESS SCHEDULE - GROUND FLOOR
ROOM OCCUPANT LOAD (PER TABLE 1004.1.2)EXITING
NO. NAME SQ. FT. OCCUPANCY FUNCTION OF SPACE
OCCUPANT LOAD
FACTOR
NO. OF
OCCUPANTS
ONE EXIT - MAX
OCCUPANT LOAD PER
OCCUPANCY
MIN. NO. OF
EXITS
MINIMUM EXITING DOOR WIDTH
(IN INCHES)
PROVIDED EXITING DOOR WIDTH (IN
INCHES)
101 (E) LOBBY 202 SF A3 Assembly (Concentrated) 5 40.4 49 1 8.1 324
102 (E) HALLWAY 3,756 SF - (none)
103 (E) MEETING ROOM 333 SF A3 Assembly (Unconcentrated) 15 22.2 49 1 4.4 36
104 (E) MEETING ROOM 237 SF A3 Assembly (Unconcentrated) 15 15.8 49 1 3.2 36
104A (E) F.R. 11 SF - (none)
105 (E) MEETING ROOM 273 SF A3 Assembly (Unconcentrated) 15 18.2 49 1 3.6 36
106 (E) MEETING ROOM 260 SF A3 Assembly (Unconcentrated) 15 17.3 49 1 3.5 72
107 (E) NURSERY 279 SF A3 Assembly (Unconcentrated) 15 18.6 49 1 3.7 36
108 (E) VOID 98 SF (none)
109 (E) OFFICE 384 SF B Offices 150 2.6 49 1 0.5 36
110 (E) I.T. ROOM 273 SF B Business Areas 150 1.8 49 1 0.4 36
111 (E) MEETING ROOM 267 SF A3 Assembly (Unconcentrated) 15 17.8 49 1 3.6 36
112 (E) MEETING ROOM 261 SF A3 Assembly (Unconcentrated) 15 17.4 49 1 3.5 36
113 (E) LUNCH ROOM 193 SF B Business Areas 150 1.3 49 1 0.3 36
114 (E) MEETING ROOM 294 SF A3 Assembly (Unconcentrated) 15 19.6 49 1 3.9 36
115 (E) JAN 20 SF - (none)
116 (E) MEN 329 SF - (none)
117 (E) WOMEN 392 SF - (none)
118 (E) LOBBY 1,832 SF A3 Assembly (Concentrated) 5 366.5 49 2 73.3 324
119 (E) AUDITORIUM 4,238 SF A3 Assembly (Concentrated) 7 605.5 49 3 121.1 180
120 (E) STORAGE 324 SF S2 Storage and Stock Rooms 500 0.6 29 1 0.1 36
121 (E) STORAGE 2,411 SF S2 Storage and Stock Rooms 500 4.8 29 1 1.0 36
123 YOUTH ROOM 1,445 SF A3 Assembly (Concentrated) 7 206.4 49 2 41.3 72
124 (E) ELECT. 113 SF - (none)
18,224 SF 1376.8
PLUMBING FIXTURE ANALYSIS
TOTAL "A-3" OCCUPANTS = 9,921 SF/30 = 331 OCCUPANTS
= 166 MEN, 166 WOMEN
WATER CLOSETS URINALS LAVATORIES DF
WO
M
E
N
ME
N
3
6*
3 2
3
WATER CLOSETS URINALS LAVATORIES DF
WO
M
E
N
M
E
N
5
9
4 4
6
TO
T
A
L
R
E
Q
'
D
TO
T
A
L
P
R
O
V
I
D
E
D
WATER CLOSETS URINALS LAVATORIES DF
WO
M
E
N
M
E
N
1
1
1 1
1
WATER CLOSETS URINALS LAVATORIES DF
WO
M
E
N
M
E
N
2
4
2 1
2
TOTAL "B" OCCUPANTS =3,959 SF / 150 = 27 OCCUPANTS
= 14 MEN, 14 WOMEN
* TOTAL # REQ'D FOR WOMEN SHALL NOT BE LESS THAN TOTAL
# WATER CLOSETS + URINALS REQ'D FOR MEN
1/8" = 1'-0"2SECOND FLOOR CODE ANALYSIS PLAN
TRUE
NORTH
PROJECT
NORTH
BUILDING OCCUPANT LOAD CALCULATIONS AND EGRESS SCHEDULE - SECOND FLOOR
ROOM OCCUPANT LOAD (PER TABLE 1004.1.2)EXITING
NO. NAME SQ. FT. OCCUPANCY FUNCTION OF SPACE
OCCUPANT LOAD
FACTOR
NO. OF
OCCUPANTS
ONE EXIT - MAX
OCCUPANT LOAD PER
OCCUPANCY
MIN. NO. OF
EXITS
MINIMUM EXITING DOOR WIDTH
(IN INCHES)
PROVIDED EXITING DOOR WIDTH (IN
INCHES)
201 (E) HALLWAY 1,302 SF B Offices 150 8.7 49 1 1.7 36
202 (E) OFFICE 351 SF B Offices 150 2.3 49 1 0.5 60
203 (E) OFFICE 302 SF B Offices 150 2.0 49 1 0.4 36
204 (E) OFFICE 492 SF B Offices 150 3.3 49 1 0.7 72
205 (E) OFFICE 375 SF B Offices 150 2.5 49 1 0.5 36
206 (E) OFFICE 196 SF B Offices 150 1.3 49 1 0.3 36
207 (E) STOR. 91 SF S2 Storage and Stock Rooms 500 0.2 49 1 0.0 36
3,109 SF 20.3
Circulation Serving A (Net)
Circulation Serving B (Gross)
19,850 SF
3,688 SF
1
1
2
2 + BF
1/8" = 1'-0"1FIRST FLOOR CODE ANALYSIS PLAN
2909 S Daimler St
4/16/2025
CL D A I M L E R S T R E E T
2909
COMPASS BIBLE CHURCH
(E
)
T
R
A
S
H
ADA ADA VAN ADA ADA
AD
A
30
0
'
-
0
"
P
.
L
.
30
0
'
-
0
"
P
.
L
.
407'-0" P.L.
407' - 0" P.L.
NORTH
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 23 24 25 26 27 28 29 30 31 32 33 34 35
36 37 38 39 40 41 45 46 47
49 50 52 54 56 58
170
61 62
63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80
81 83 84 85 87 88 89 91 92 93 95 96 97
51 53 55 57 59 60
82 86 90 94
42 43 44 48
99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120
123
124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139
140
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
141
171
172
173
174
175
176
177
178
179
180
98
21 22
ADA VAN ADA
121
122
ADA VANADA
R 42' - 0"
R 30' - 0"R 42' - 0"R 30' - 0"
ADJACENT TENANT-
NOT A PART
(EXISTING)
54' - 5"
EXISTING STAGING AREA
ADJACENT TENANT-
NOT A PART
29152917
4' - 0"
200
AS
S
U
M
E
D
P
R
O
P
E
R
T
Y
L
I
N
E
20' - 0"
20' - 0"
EXISTING MAXIMUM AREA OF EXTERIOR
WALL OPENINGS = NO LIMIT (UNPROTECTED,
SPRINKLERED, 20' FIRE SEPARATION
DISTANCE) PER CBC TABLE 705.8
EXISTING (3-HOUR MIN. FIRE-RATED)
CONCRETE TILT-UP WALL; NO
OPENINGS
EXISTING MAXIMUM AREA OF EXTERIOR
WALL OPENINGS = NO LIMIT
(UNPROTECTED, SPRINKLERED, 20' FIRE
SEPARATION DISTANCE) PER CBC
TABLE 705.8
EV EV
EXISTING ACCESSIBLE PARKING AND PATH OF
TRAVEL TO BUILDING ENTRY
EXISTING ACCESSIBLE PARKING AND PATH OF
TRAVEL TO BUILDING ENTRY
EXISTING ACCESSIBLE PARKING AND PATH OF
TRAVEL TO BUILDING ENTRY
AREA OF WORK
EXISTING PARKING TABULATIONS
ADDRESS USE AREA RATIO RE'D PARKING
2909 DAIMLER CHURCH (AUDITORIUM)* 4,180 SF 1 SPACE PER 50 SF 84 SPACES
CHURCH (H.S. YOUTH)* 767 SF**1 SPACE PER 50 SF 15 SPACES
2915 DAIMLER OFFICE 11,944 SF 1 SPACE PER 1,000 SF 36 SPACES
2917 DAIMLER OFFICE 11,944 SF 1 SPACE PER 1,000 SF 36 SPACES
TOTAL PARKING SPACES REQUIRED 171 SPACES
TOTAL PARKING SPACES PROVIDED 200 SPACES
STANDARD = 191
ACCESSIBLE = 9
(6 STANDARD + 3 VAN)
NOTES:
* SEATING AREAS WITHOUT FIXED SEATS. "SEATING AREAS" SHALL INCLUDE CONGREGATION SEATING,
PRAYER AND CRY ROOMS, PASTOR AND CHOIR AREAS, AND SIMILAR AREAS
** 1/2 THE TOTAL AREA OF THE HIGH SCHOOL YOUTH ROOM WAS USED FOR THIS CALCULATION SINCE
ROUGHLY 1/2 OF HIGH SCHOOLERS ARE ELIGIBLE TO OBTAIN A DRIVER'S LICENSE. ON AVERAGE THE
ACTUAL NUMBER OF LICENSED HIGH SCHOOLERS IS MUCH LESS THAN 1/2
EXISTING PLANNING / ZONING TABULATIONS
PROJECT:COMPASS BIBLE CHURCH
PROJECT ADDRESS:2909 DAIMLER STREET
SANTA ANA, CA 92705
LEGAL DESCRIPTION:THE LAND REFERRED TO HEREIN BELOW IS
SITUATED IN THE COUNTY OF ORANGE, STATE
OF CALIFORNIA, & IS DESCRIBED AS FOLLOWS:
PARCEL 2, IN THE CITY OF SANTA ANA, COUNTY
OF ORANGE, STATE OF CALIFORNIA, AS
SHOWN ON A MAP FILED IN BOOK 30 PAGE 19
OF PARCEL MAPS, IN THE OFFICE OF THE
COUNTY RECORDER OF ORANGE COUNTY,
CALIFORNIA. EXCEPTIN THEREFROM, ONE-
HALF OF ALL OIL, GAS, MINERALS,
HYDROCARBONS & ASSOCIATED SUBSTANCES
LYING BELOW A DEPTH OF 500 FT. FROM THE
SURFACE OF SAID LAND, W/O THE RIGHT OF
SURFACE OR SUBSURFACE ENTRY ABOVE A
DEPTH OF 500 FT. FROM THE SURFACE OF SAID
LAND, AS RESERVED IN DEED RECORDED
AUGUST 9, 1968 IN BOOK 8685 PAGE 900 OF
OFFICIAL RECORDS OF ORANGE COUNTY.
ACCESSORS PARCEL NO.:430-191-08
FLOOR AREA RATIO:0.39
ZONING DESIGNATION:PROFESSIONAL (P)
LAND USE DESIGNATION:PROFESSIONAL & ADMINISTRATIVE OFFICE (PAO)
LOT NUMBER(S):LOT 116
LOT AREA:122,099 SF = 2.803 AC.
NUMBER OF STORIES:2
CONSTRUCTION TYPE:TYPE III-B
OCCUPANCY CLASSIFICATION:ASSEMBLY (A-3), BUSINESS (B), STORAGE (S-2)
*C.B.C. SEC. 508.3 NON-SEPARATED OCCUPANCIES
ALLOWABLE ACTUAL
BUILDING AREA:28,500 SF 23,538 SF
BUILDING HEIGHT:75 FT.+/-22 FT.
NO. OF STORIES:THREE TWO
ZONING:
REQUIRED PROVIDED
MAX. STRUCTURE HEIGHT:+35 FT.+/-22 FT.
SETBACKS:
FRONT:15 FT.54.28 FT.
SIDE (STREET ABUTMENT):15 FT.N/A
SIDE (INT. SIDE PROP. LINES): 5 FT.35.00 FT.
REAR (*):50 FT.N/A
REAR:10 FT.44.61 FT.
M. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECTM. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECT
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
PROJECT NUMBER:
All ideas, designs and plans indicated or represented
by these drawings are owned by and are the property
of Elements Architecture, Inc. and were created and
developed for use in connection with the specified
project. None of such ideas, designs, or plans shall
be used for any purpose whatsoever without the
written permission of Elements Architecture.
Elements Architecture, Inc.
PROJECT NAME:
NO.DESCRIPTION DATE
M. Steven Camp, AIA
Scott Holland, AIA
PROJECT ADDRESS:
SHELLEY MACDONALD
EA
SHELLEY MACDONALD
1/
9
/
2
0
2
5
8
:
2
2
:
2
8
A
M
21.105
TENANT
IMPROVEMENT
(YOUTH ROOM)
2909 DAIMLER STREET
SANTA ANA, CA 92705
A1.1
EXISTING SITE PLAN
(FOR REFERENCE ONLY)
COMPASS BIBLE CHURCH,
TUSTIN SANTA ANA
1" = 20'-0"1EXISTING SITE PLAN (FOR REFERENCE ONLY)
NOTE: NO PUBLIC WAY EXISTS ALONG DAIMLER STREET OR ADJACENT STREETS
NO PROPOSED SITEWORK -PLAN &
TABULATIONS SHOWN FOR REFERENCE ONLY
CONDITIONS OF APPROVAL FOR CONDITIONAL USE PERMIT NO. 2022-13 (FOR REFERENCE)
2909 S Daimler St
4/16/2025
UP UP
WH
UP
UP
UP
FD
FD
PROJECT
NORTH
TRUE
NORTH
(E) STAIR
1 98765423
A
B
C
ADJACENT TENANT (NOT IN SCOPE)
(E) 3-HOUR FIRE WALL(E) 3-HOUR FIRE WALL
47
'
-
8
"
-
V
.
I
.
F
.
NOTES:
• SEE SITE PLAN FOR ASSUMED PROPERTY LINE INFORMATION
• EXISTING EXTERIOR WALLS ARE 8" THICK CONCRETE TILT-UP, WHICH HAVE A FIRE-RESISTANCE RATING OF 4 HOURS PER CBC TABLE 721(2)
• FIRE WALL SHALL EXTEND 18" PAST EXTERIOR SURFACE OF EXTERIOR WALL PER CBC 706.5 (EAST SIDE)
• FIRE WALL PERMITTED TO TERMINATE AT INTERIOR SURFACE OF EXTERIOR WALL (WEST SIDE), PROVIDED EXTERIOR WALL HAS A 1-HOUR MIN. FIRE-
RESISTANCE RATING FOR A HORIZONTAL DISTANCE OF NOT LESS THAN 4 FEET, WITH NO OPENINGS -PER CBC 706.5 EXCEPTION 1
• FIRE-RESISTANCE RATING OF ADJACENT EXTERIOR WALLS IS 1-HOUR MIN.; WITH NO OPENINGS, FOR A MINIMUM OF 4 FEET FROM THE INTERSECTION
OF THE FIRE WALL TO EXTERIOR WALL (AS REQUIRED BY CBC 706.5.1 #1)
EXISTING AREA TO REMAIN
(E)
OFFICE
109
(E)
NURSERY
107
(E) VOID
108
(E)
MEETING
ROOM
106
(E)
MEETING
ROOM
105
(E) I.T.
ROOM
110
(E)
MEETING
ROOM
111
(E)
MEETING
ROOM
112
(E)
LUNCH
ROOM
113
(E)
MEETING
ROOM
104
(E) F.R.
104A
(E)
MEETING
ROOM
103
(E)
HALLWAY
102
(E)
LOBBY
118
(E)
MEETING
ROOM
114
(E) JAN
115
(E) MEN
116
(E)
WOMEN
117
(E)
AUDITORIUM
119
(E)
STORAGE
120
(E)
STORAGE
121
YOUTH
ROOM
123
DOOR
3' - 0"6"
24' - 7 1/2" - V.I.F.
ALIGN (E)
ELECT.
124
36' - 2"24' - 8"24' - 0"24' - 0"24' - 0"24' - 0"24' - 0"20' - 3"
201' - 1" (EXISTING OVERALL BUILDING)
50
'
-
3
"
50
'
-
3
"
10
0
'
-
6
"
(
E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
B
U
I
L
D
I
N
G
)
2
A5.1
5.01
8.01
9.01
9.02
1
A5.1
(E)
LOBBY
101
2.07
2.07
EXISTING CONSTRUCTION SHALL REMAIN
LEGEND
PROPOSED CONSTRUCTION;
INTERIOR NON-LOAD-BEARING, FULL-HEIGHT M. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECTM. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECT
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
PROJECT NUMBER:
All ideas, designs and plans indicated or represented
by these drawings are owned by and are the property
of Elements Architecture, Inc. and were created and
developed for use in connection with the specified
project. None of such ideas, designs, or plans shall
be used for any purpose whatsoever without the
written permission of Elements Architecture.
Elements Architecture, Inc.
PROJECT NAME:
NO.DESCRIPTION DATE
M. Steven Camp, AIA
Scott Holland, AIA
PROJECT ADDRESS:
SHELLEY MACDONALD
EA
SHELLEY MACDONALD
1/
9
/
2
0
2
5
8
:
2
2
:
3
6
A
M
21.105
TENANT
IMPROVEMENT
(YOUTH ROOM)
2909 DAIMLER STREET
SANTA ANA, CA 92705
A2.1
PROPOSED GROUND
FLOOR PLAN
COMPASS BIBLE CHURCH,
TUSTIN SANTA ANA
ARCHITECTURAL KEYNOTES
## DESCRIPTION
2.07 EXISTING EXIT DOOR WITH PANIC HARDWARE - V.I.F.
5.01 NEW INTERIOR NON-LOAD-BEARING FULL-HEIGHT PARTITION: 6" 25 GA. MTL STUDS AT
16" O.C. MAX WITH ACOUSTIC BATT INSULATION FULL DEPTH OF STUD & 5/8" GYP. BD.
BOTH SIDES
8.01 NEW INTERIOR 3'-0" W X 8'-0" H DOOR & FRAME: 1 3/4" SCW WOOD WITH WOOD VNR
FINISH & PAINTED H.M. FRAME TO MATCH EXISTING ADJACENT DOORS.
9.01 ADJUST EXISTING FLOOR FINISH AT NEW PARTITION AS REQUIRED; PROVIDE NEW
WALL BASE AT BOTH SIDES OF WALL TO MATCH EXISTING ADJACENT (MANUF: BURKE,
PRODUCT: RUBBER MYTE TP, COLOR: ROCKY 660, HEIGHT: 2.5" - VERIFY)
9.02 PROVIDE NEW PAINTED FINISH AT BOTH SIDES OF NEW PARTITION TO MATCH
EXISTING ADJACENT (MANUF: SHERWIN WILLIAMS, COLOR: SW7022 ALPACA - VERIFY)
1/8" = 1'-0"1PROPOSED FIRST FLOOR PLAN
2909 S Daimler St
4/16/2025
DN
(OPEN TO BELOW)
PROJECT
NORTH
TRUE
NORTH
1 98765423
A
B
C
10
0
'
-
6
"
(
E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
B
U
I
L
D
I
N
G
)
201' - 1" (EXISTING OVERALL BUILDING)
36' - 2" 24' - 8" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 19' - 7"0' - 8"
ADJACENT TENANT (NOT IN SCOPE)
50
'
-
3
"
50
'
-
3
"
(E)
HALLWAY
201
(E)
OFFICE
202
(E)
OFFICE
203
(E)
OFFICE
204
(E)
OFFICE
205
(E)
OFFICE
206
(E)
STOR
207
M. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECTM. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECT
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
PROJECT NUMBER:
All ideas, designs and plans indicated or represented
by these drawings are owned by and are the property
of Elements Architecture, Inc. and were created and
developed for use in connection with the specified
project. None of such ideas, designs, or plans shall
be used for any purpose whatsoever without the
written permission of Elements Architecture.
Elements Architecture, Inc.
PROJECT NAME:
NO.DESCRIPTION DATE
M. Steven Camp, AIA
Scott Holland, AIA
PROJECT ADDRESS:
SHELLEY MACDONALD
EA
SHELLEY MACDONALD
1/
9
/
2
0
2
5
8
:
2
2
:
4
3
A
M
21.105
TENANT
IMPROVEMENT
(YOUTH ROOM)
2909 DAIMLER STREET
SANTA ANA, CA 92705
A2.2
EXISTING SECOND
FLOOR PLAN (FOR
REFERENCE ONLY)
COMPASS BIBLE CHURCH,
TUSTIN SANTA ANA
1/8" = 1'-0"1EXISTING SECOND FLOOR PLAN
NO PROPOSED WORK AT SECOND FLOOR -
PLAN SHOWN FOR REFERENCE ONLY 2909 S Daimler St
4/16/2025
(OPEN CEILING)
1 98765423
A
B
C
PROJECT
NORTH
TRUE
NORTH
10
0
'
-
6
"
(
E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
B
U
I
L
D
I
N
G
)
201' - 1" (EXISTING OVERALL BUILDING)
36' - 2 5/16" 24' - 7 11/16" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 24' - 0" 19' - 7"8"
ADJACENT TENANT (NOT IN SCOPE)
50
'
-
3
"
50
'
-
3
"
(OPEN CEILING)
(OPEN CEILING)
(OPEN CEILING)
EQ
20
'
-
0
"
EQ
EQ 16' - 0"EQ
D D
DD (R)
2
A5.1
(R)
26.01
26.02
2.04
23.01
23.02
2.05
2.05
YOUTH
ROOM
123
(E)
STORAGE
121
(E)
AUDITORIUM
119
(E)
LOBBY
118
(E)
STORAGE
120
(E)
HALLWAY
102
(E)
OFFICE
109
(E)
NURSERY
107
(E) I.T.
ROOM
110
(E)
MEETING
ROOM
106
(E)
MEETING
ROOM
105
(E)
MEETING
ROOM
111
(E)
MEETING
ROOM
112
(E)
LUNCH
ROOM
113
(E)
MEETING
ROOM
103
(E)
MEETING
ROOM
104
(E) MEN
116
(E)
WOMEN
117
(E)
MEETING
ROOM
114
EXISTING AREA TO REMAIN
CEILING & LIGHTING LEGEND
EXISTING
ILLUMINATED EMERGENCY SIGN -
CEILING / WALL MOUNTED
PROPOSED
SUSPENDED PENDANT LIGHT FIXTURE -B.O.
FIXTURE = 14'-0" A.F.F.*D
1. MEANS OF EGRESS LIGHTING SHALL BE PROVIDED W/ AN
ILLUMINATION LEVEL OF NOT LESS THAN 1 FOOT-CANDLE @ THE
WALKING SURFACE. (C.B.C. §1008.2)
2. WHERE BUILDINGS, ROOMS, OR SPACES REQUIRE TWO OR MORE
MEANS OF EGRESS AN EMERGENCY POWER BACKUP SUPPLY SHALL
BE PROVIDED FOR A DURATION OF NOT LESS THAN 90 MIN. (C.B.C. §
1008.3 THRU §1008.3.4)
3. VERIFY ALL EXISTING CONDITIONS IN FIELD UPON DEMOLITION &
NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES RELATED
TO CEILINGS, STRUCTURE, LIGHTING, OR MECHANICAL
INFORMATION.
4. DUCTWORK, CONDUIT, PIPE, WIRE, ETC. SHALL BE HIDDEN FROM
VIEW & CONCEALED W/IN WALL FRAMING, FLOOR FRAMING,
SOFFITS, CHASES, & CEILING PLENUM SPACES WHENEVER
POSSIBLE. IF VISIBLE, DUCTWORK, CONDUIT, PIPE, WIRE, ETC.
SHALL BE INSTALLED IN A NEAT & ORDERLY MANNER. EXT. FINISH
SHALL BE MODIFIED (I.E. PAINT) TO MATCH NEAREST ADJACENT
SURFACE.
5. EXIT SIGNS SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED.
(C.B.C. §1013.3)
6. ELECTRICALLY POWERED EXIT SIGNS SHALL BE LISTED & LABELED
IN ACCORDANCE W/ UL 924. (C.B.C. §1013.5)
7. EMERGENCY POWER SUPPLY TO ILLUMINATE EXIT SIGNS FOR A
DURATION OF NOT LESS THAN 90 MIN.
8. IN EVENT OF POWER SUPPLY FAILURE, AN EMERGENCY ELECTRICAL
SYSTEM SHALL AUTOMATICALLY ILLUMINATE AISLES, LOBBY,
CORRIDOR, & EXT. DOOR LANDING. EMERGENCY POWER SYSTEM
SHALL PROVIDE POWER FOR A DURATION OF NOT LESS THAN 90
MIN. & SHALL CONSIST OF STORAGE BATTERIES, UNIT EQUIPMENT
OR AN ON-SITE GENERATOR. INITIAL ILLUMINATION AVERAGE OF 1
FOOT-CANDLE & MIN. 0.1 FOOT-CANDLE @ FLOOR LEVEL. (C.B.C.
1008.3.4.)
9. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE
INSTALLATION OF ALL TRADES, INCLUDING DUCTWORK, CONDUIT,
UTILITY LINES, AND FIXTURES. AT EXPOSED/OPEN CEILINGS,
DUCTWORK SHALL BE MOUNTED ABOVE LIGHT FIXTURES AS HIGH
AS POSSIBLE -CONTRACTOR SHALL NOTIFY ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES AS TO MOUNTING HEIGHTS
OF ALL EXPOSED COMPONENTS, OR ANY EXISTING UNFORESEEN
CONDITIONS PREVENTING COMPLIANCE WITH MOUNTING HEIGHTS
PER PLANS
10. ALL EXPOSED ELEMENTS SHALL BE PAINTED TO MATCH ADJACENT
SURFACE UNLESS NOTED OTHERWISE. ALL EXPOSED REGISTERS
SHALL HAVE FINISH TO MATCH ADJACENT SURFACE.
NOTES
RELOCATED SUSPENDED PENDANT LIGHT FIXTURE -
B.O. FIXTURE = 14'-0" A.F.F.*D (R)
*VERIFY FINAL EXISTING RELOCATED / NEW
PENDANT LOCATIONS WITH EMERGENCY BACKUP
REQUIREMENTS -SEE ELECT.
M. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECTM. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECT
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
PROJECT NUMBER:
All ideas, designs and plans indicated or represented
by these drawings are owned by and are the property
of Elements Architecture, Inc. and were created and
developed for use in connection with the specified
project. None of such ideas, designs, or plans shall
be used for any purpose whatsoever without the
written permission of Elements Architecture.
Elements Architecture, Inc.
PROJECT NAME:
NO.DESCRIPTION DATE
M. Steven Camp, AIA
Scott Holland, AIA
PROJECT ADDRESS:
SHELLEY MACDONALD
EA
SHELLEY MACDONALD
1/
9
/
2
0
2
5
8
:
2
3
:
0
1
A
M
21.105
TENANT
IMPROVEMENT
(YOUTH ROOM)
2909 DAIMLER STREET
SANTA ANA, CA 92705
A4.1
PROPOSED GROUND
FLOOR REFLECTED
CEILING PLAN
COMPASS BIBLE CHURCH,
TUSTIN SANTA ANA
ARCHITECTURAL KEYNOTES
## DESCRIPTION
2.04 EXISTING OPEN CEILING WITH SCRIM SHEET O/ R-30 BATT INSULATION, TYP. - MODIFY,
RE-ATTACH INSULATION AND REPLACE SCRIM SHEET AT NEW PARTITION LOCATION AS RQ'D
2.05 EXISTING EXIT SIGNAGE TO REMAIN - SEE ELECTRICAL FOR ALL REQUIREMENTS, VERIFY IN
FIELD
23.01 NEW DUCT WITH SIDE REGISTERS PER MECHANICAL - MOUNT AS HIGH AS POSSIBLE AT
OPEN CEILING
23.02 NEW WALL-MOUNTED TRANSFER GRILLE PER MECHANICAL - INSTALL SOUND BOOT AND
PROVIDE ACOUSTICAL CAULKING AT ALL PENETRATIONS. PAINT DEVICE IN COMPLETE TO
MATCH ADJ. WALL FINISH
26.01 EXISTING RELOCATED SUSPENDED PENDANT LIGHT FIXTURE, TYP. OF (2)
26.02 NEW SUSPENDED PENDANT LIGHT FIXTURE, TYP. OF (2)
1/8" = 1'-0"1FIRST FLOOR REFLECTED CEILING PLAN
2909 S Daimler St
4/16/2025
YOUTH
ROOM
123
(E)
STORAGE
121
6" 25 GA. MTL. STUD. @ 16" O.C. MAX;
VERIFY STUD SIZE PER
(1) LAYER 5/8" GYP. BD. FULL-HEIGHT OF WALL;
SEE FOR FASTENING REQUIREMENTS
ACOUSTIC BATT INSULATION FULL-DEPTH OF STUD
20
'
-
8
1
/
2
"
(
E
)
-
V
.
I
.
F
.
A5.1
4
A5.1
5
(1) LAYER 5/8" GYP. BD. FULL-HEIGHT OF WALL
EXISTING ROOFING ASSEMBLY O/ PLYWD
SHEATHING, TYP.
6
A5.1
7
A5.1
EXISTING R-30 BATT INSULATION WITH SCRIM
SHEET -MODIFY & RE-ATTACH AT NEW
PARTITION AS RQ'D.
NEW WALL BASE TO MATCH EXISTING
ADJACENT, BOTH SIDES OF WALL
EXISTING LUXURY VINYL FLOORING -VERIFY
EXISTING CONC. SLAB
EXISTING WD ROOF FRAMING, TYP.
1. ALL METAL STUDS USED SHALL BE PER ICC-ESR-3064P.
2. ALL BRIDGING, BLOCKING OR END BEARING STIFFENERS SHALL BE AS REQUIRED BY
MANUFACTURER UNLESS NOTED OTHERWISE ON THE DRAWINGS.
3. ALL STUDS SHALL CONFORM TO ICC-ESR-3064P.
4. UNLESS OTHERWISE NOTED ON PLANS, SEE FOLLOWING GUIDELINE FOR STUD SIZE &
SPACING FOR INTERIOR PARTITIONS (DRYWALL FINISH ON BOTH SIDES).
5. TOP WIDE FLANGE SLIP TRACK ATTACHED TO STRUCTURE SHALL BE PER SCHEDULE
BELOW.
6. PROVIDE NO. 6 TYPE 'S' DRYWALL SCREWS SPACED @ 12" O.C. FOR STUDS @ 24"
SPACING, & 16" O.C. FOR STUDS @ 12" & 16" SPACING.
7. PROVIDE 16 GA. SLIP TRACK PER SLIP TRACK DETAIL.
COMPOSITE LIMITING HEIGHTS, DEFLECTION LIMIT L/120, 5 PSF
SIZE
600S125-33
SPACING
16"
HEIGHT
32' -1"
SPACING
24"
HEIGHT
27' -10"
NOTE:
FASTENER PENETRATION: WOOD
PENETRATION SHALL BE LONG ENOUGH TO PENETRATE INTO WOOD FRAMING MEMBERS NOT
LESS THAN:
• SCREWS -5/8"
• NAILS -3/4"
FASTENER PENETRATION: STEEL
• SCREWS INTO METAL MEMBERS NOT LESS THAN 3/8"
GYP. BD.
THICKNESS
5/8"
5/8"
5/8"
5/8"
5/8"
ERECTION OF
FRAMING
HORIZONTAL
VERTICAL
HORIZONTAL
VERTICAL
HORIZONTAL
MAX. FRAMING
SPACING
24" O.C.
16" O.C.
16" O.C.
24" O.C.
24" O.C.
MAX. NAIL
SPACING
8" O.C.
8" O.C.
7" O.C.
7" O.C.
8" O.C.
MAX. SCREW
SPACING
12" O.C.
16" O.C.
12" O.C.
12" O.C.
12" O.C.
TYPE SCREWS
TYPE 'S' SCREWS
TYPE 'S-12' SCREWS
TYPE 'W' SCREWS
ATTACHMENT APPLICATION
GYP. TO LIGHT-GA. STL. FRAMING (NON-LOAD BEARING)
GYP. TO HEAVY-GA. STIL. FRAMING (STRUCTURAL)
GYP. TO WOOD FRAMING
SCREW TYPE & APPLICATION TABLE
FASTENER SPACING - (1) LAYER GYP. BD.
2"
1/2"1/2"
(1) LAYER 5/8"
GYP.BD. EA. SIDE
MTL. STUD WALL PER
PLAN W/ BATT INSUL.
MTL. BOX BEAM @
HEAD
PROVIDE SEALANT
@ BOTH SIDES, TYP.
PAINTED H.M. FRAME
JAMB BEYOND
S.C.W. DOOR WITH WD
VNR FINISH
2"
1/
2
"
1/
2
"
(1) LAYER 5/8" GYP.BD.
BOTH SIDES
MTL. STUD WALL PER
PLAN W/ BATT INSUL.
DBL. MTL. STUD
PROVIDE SEALANT
@ BOTH SIDES, TYP.
PAINTED H.M. FRAME
S.C.W. DOOR WITH WD
VNR FINISH
H.M. JAMB BEYOND
BURKE FLOORING REDUCER
TRANSITION STRIP AS RQ'D
LUXURY VINYL TILE -VERIFY
1
2
MAX. SLOPE
1/
4
"
M
A
X
.
S.C.W. DOOR WITH WD
VNR FINISH
5/
8
"
1
1
/
4
"
5/
8
"
2
1
/
2
"
1"1/4"
SIDE VIEW
SECTION
WIDTH VARIES
STUD WALL
ISOMETRIC
1/
2
"
1
1
/
4
"
1
1
/
4
"
DRYWALL SCREWS, TYP.
#8 x 9/16" WAFERHEAD
FRAMING SCREWS @ EA. STUD
TO TRACK (16" O.C. MAX.), TYP.;
ENGAGE SCREWS @ LEAST 3
THREADS -DO NOT FULLY
TIGHTEN SCREWS
METAL STUD WALL
SLOTTED TRACK
STRUCTURE
(2) #10 SMS SCREWS
@ 16" O.C.
2x WD. BLKG. TO
MATCH PURLIN SIZE
(E) INSULATION W/
SCRIM
(E) ROOF SHEATHING &
FRAMING -VERIFY
16 GA. MIN.
SLOTTED TRACK
#8 WAFERHEAD
SCREW EA. SIDE
WALL PER PLAN W/
ACOUS. INSUL. FULL
DEPTH OF STUD, WHERE
OCCURS
5/8" GYP.BD. EA. SIDE
(2) #10 SCREWS
PER MEMBER
A5.1
3
EXTEND WALL FRAMING,
FINISH AND INSULATION TO
B.O. ROOF DECKING
1
1
/
2
"
(E) PLYWD. ROOF SHEATHING
(2) 2x WD. BLKG. TO
MATCH PURLIN SIZE
(E) INSULATION W/ SCRIM
(E) PURLIN FRAMING
16 GA. MIN.
SLOTTED TRACK
#8 WAFERHEAD
SCREW EA. SIDE
WALL PER PLAN W/ ACOUS.
INSUL. FULL DEPTH OF
STUD, WHERE OCCURS
5/8" GYP.BD. EA. SIDE
(2) #10 SCREWS
PER MEMBER
MI
N
.
1/
2
"
A5.1
3
1
1
/
2
"
PARALLEL
PERPENDICULAR
(E) CONC. SLAB
FLOORING PER FIN. SCHED.
SEALANT EA. SIDE
WALL BASE PER FIN. SCHED.
HILTI X-U UNIVERSAL
POWER-DRIVEN FASTENER
W/ 1" MIN. EMBED @ 16" O.C.
(ICC #ESR 2269)
MTL. STUD PER PLAN W/
ACOUS. BATT INSUL. FULL
DEPTH OF STUD, U.N.O.
(1) LAYER 5/8" GYP.
BD. EA. SIDE
82
A5.1
+/
-
2
0
'
-
8
1
/
2
"
(
E
)
-
V
.
I
.
F
.
8.01
5.019.01
9.02
8
A5.1
10
A5.1
9
A5.1
23.02
ASSISTIVE
LISTENING
SYSTEMS
AVAILABLE
R 1/2" TYP.
NOTES:
1. MIN. 1" LETTERS & NUMBERS WITH CONTRASTING BACKGROUND.
2. LOCATE SIGN IN VISIBLE LOCATION OR AS DETERMINED BY THE FIRE MARSHAL.
3. MOUNT AT HEIGHT PER
0'
-
6
"
1' - 0"
14
A5.1
MAXIMUM
OCCUPANCY
XX PERSONS
R 1/2" TYP.
NOTES:
1. MIN. 1" LETTERS & NUMBERS WITH CONTRASTING BACKGROUND.
2. LOCATE SIGN IN VISIBLE LOCATION OR AS DETERMINED BY THE FIRE MARSHAL.
3. MOUNT AT HEIGHT PER
0'
-
6
"
14
A5.1
SEE SIGNAGE NOTES, FOR MORE INFO.
SIGNS SHALL BE MOUNTED AT LATCH SIDE OF DOOR PER
EXIT
R 1/2" , TYP.
6"
4"
BRAILLE TEXT, TYP.
RAISED TACTILE TEXT, TYP.
WHERE PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS & SPACES, RAISED LETTERS
SHALL ALSO BE PROVIDED. THESE LETTERS SHALL BE SANS SERIF UPPERCASE SIZED PER
11B-703.5, AND ACCOMPANIED BY GRADE 2 BRAILLE SIZED PER 11B-703.3.1.
14
A5.1
15
A5.1
TYP.
9"EQ EQ
60
"
M
A
X
A
.
F
.
F
.
T
O
H
I
G
H
E
S
T
C
H
A
R
A
C
T
E
R
S
48
"
M
A
X
A
.
F
.
F
.
T
O
L
O
W
E
S
T
B
R
A
I
L
L
E
F.F.
48" MIN. A.F.F. OR GROUND
SURFACE, MEASURED FROM
BASELINE OF LOWEST LINE
OF BRAILLE CELLS & 60" MAX.
A.F.F. OR GROUND SURFACE,
MEASURED FROM BASELINE
OF HIGHEST LINE OF RAISED
CHARACTERS PER 2019 C.B.C.
11B-703.4.1
58
"
M
I
N
.
-
6
0
"
M
A
X
.
,
T
Y
P
.
ME
A
S
U
R
E
D
F
R
O
M
C
E
N
T
E
R
O
F
S
I
G
N
TO
F
.
F
.
P
E
R
2
0
1
9
C
.
B
.
C
.
7
0
3
.
7
.
2
.
6
WALL SIGN ALONG LATCH SIDE OF
DOOR (OR NEAREST ADJACENT
WALL) W/ CLEAR FLOOR SPACE OF
18" x 18", CENTERED ON TACTILE
CHARACTERS, PROVIDED BEYOND
ARC OF DOOR SWING, TYP. PER
2019 C.B.C. 11B-703.4.2
DOOR SIGN, TYP.
1. CHARACTER TYPE:
CHARACTERS ON SIGNS SHALL BE RAISED 1/32" (0.794 MM) MINIMUM & SHALL BE SANS
SERIF UPPERCASE CHARACTERS ACCOMPANIED BY BRAILLE (SEE NOTE #4 BELOW).
2. CHARACTER SIZE:
RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8" (15.9 MM) & A MAXIMUM OF 2" (51
MM) HIGH, BASED ON HEIGHT OF UPPERCASE LETTER "I". (2019 C.B.C. 11B-703.2.5)
3. PROPORTIONS:
VISUAL CHARACTERS ON SIGNS SHALL BE SELECTED FROM FONTS WHERE WIDTH OF
UPPERCASE LETTER "O" IS 60% MINIMUM & 110% MAXIMUM OF HEIGHT OF UPPERCASE
LETTER "I". STROKE THICKNESS OF UPPERCASE LETTER "I" SHALL BE 15% MAXIMUM OF
HEIGHT OF CHARACTER. (2019 C.B.C. 11B-703.2.4 & 11B-703.2.6)
4. BRAILLE:
CONTRACTED (GRADE 2) BRAILLE SHALL BE USED WHEREVER BRAILLE IS REQUIRED IN
OTHER PORTIONS OF THESE STANDARDS. BRAILLE DIMENSIONS SHALL COMPLY WITH
2019 C.B.C. TABLE 11B-703.3.1.
MI
N
.
0.
3
9
5
"
MA
X
.
0.
4
0
0
"
0.100"
0.300"
0.
0
5
9
M
I
N
.
0.
0
6
3
M
A
X
.
0.
0
3
7
"
M
A
X
.
0.
0
2
5
"
M
I
N
.
BRAILLE DOT
RAISED SECTION:
ROUNDED DOT (ACCEPTABLE)
SQUARE DOT (NOT ACCEPTABLE)
BRAILLE CELL
M. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECTM. STEVEN
CAMP
C-18,407
JUN. 30, 2025
RENEWAL DATESTATEOFCALIFORNIA
LICENSED A RCHITECT
PROJECT ARCHITECT:
PROJECT MANAGER:
DRAWN BY:
PROJECT NUMBER:
All ideas, designs and plans indicated or represented
by these drawings are owned by and are the property
of Elements Architecture, Inc. and were created and
developed for use in connection with the specified
project. None of such ideas, designs, or plans shall
be used for any purpose whatsoever without the
written permission of Elements Architecture.
Elements Architecture, Inc.
PROJECT NAME:
NO.DESCRIPTION DATE
M. Steven Camp, AIA
Scott Holland, AIA
PROJECT ADDRESS:
SHELLEY MACDONALD
EA
SHELLEY MACDONALD
1/
9
/
2
0
2
5
8
:
2
3
:
1
0
A
M
21.105
TENANT
IMPROVEMENT
(YOUTH ROOM)
2909 DAIMLER STREET
SANTA ANA, CA 92705
A5.1
SECTIONS & DETAILS
COMPASS BIBLE CHURCH,
TUSTIN SANTA ANA
1/2" = 1'-0"2WALL SECTION
12" = 1'-0"6INT. NON-LOAD-BEARING PARTITION SCHEDULE
12" = 1'-0"7GYP. BD. FASTENER SCHEDULE
DOOR NOTES
1. PANIC HARDWARE SHALL BEINSTALLED WHEN OCCUPANT LOAD IS GREATER THAN 50, U.N.O.
2. EXIT DOORS SHALL ONLY BE EQUIPPED W/ NO-KNOWLEDGE, SINGLE-ACTION HARDWARE.
LOCKS THAT REQUIRE KEYS (SUCH AS DEAD BOLTS) OR ADDITIONAL ACTIONS TO OPERATE
(SUCH AS MANUAL BOLTS) ARE NOT PERMITTED. (C.B.C. §1010.1.9, §1010.1.9.4, §1010.1.9.5)
3. CHANGES IN LEVEL BETWEEN 1/4 IN. HIGH MIN. & 1/2 IN. HIGH MAX. SHALL BE BEVELED W/ A
SLOPE NOT STEEPER THAN 1:2. (C.B.C. §11B-303.3)
4. THRESHOLDS @ DOORWAYS SHALL NOT EXCEED 1/2" A.F.F. OR LANDING FOR OTHER DOORS.
RAISED THRESHOLDS & FLOOR LEVEL CHANGES GREATER THAN 1/4" @ DOORWAYS SHALL BE
BEVELED W/ SLOPE NOT GREATER THAN ONE UNIT VERT. IN TWO UNITS HORZ. (C.B.C. §
1010.1.7)
5. DOOR HARDWARE SHALL BE INSTALLED 34" MIN. & 44" MAX. A.F.F. (C.B.C. §1010.1.9.2 &
11B-404.2.7)
6. PROVIDE BACKING BEHIND ALL WALL-MOUNTED DOOR STOPS.
7. FORCE OF PUSHING OR PULLING OPEN INTERIOR SWINGING EGRESS DOORS, OTHER THAN
FIRE DOORS, SHALL NOT EXCEED 5 LBS. FOR OTHER SWINGING DOORS, AS WELL AS SLIDING
& FOLDING DOORS, DOOR LATCH SHALL RELEASE WHEN SUBJECTED TO A 15 LB. FORCE.
(C.B.C. §1010.1.3)
8. ALL DOORS W/ LATCH & LOCK SHALL HAVE SINGLE-ACTION LEVER HARDWARE WHICH
RETRACTS BOTH LOCK & LATCH FROM EXIT SIDE W/ A SINGLE OPERATION. (C.B.C. §1008.1.9.5,
ALTERNATE: PROVIDE A SIGN PER C.B.C. §1008.1.9.3)
9. CONTRACTOR SHALL VERIFY CONDITION OF EXISTING EGRESS DOORS & MAKE ADJUSTMENTS
&/OR REPAIR DOOR HARDWARE SO THAT DOORS COMPLY W/ REQS. OF C.B.C. §11B-404;
INCLUDING DOOR THRESHOLD (C.B.C. §11B-404.2.5), DOOR HARDWARE (C.B.C. §11B-404.2.7),
CLOSING SPEED (C.B.C. §11B-404.2.8), OPENING FORCE (C.B.C. §11B-404.2.9)
DOOR HARDWARE
(2)HINGES BB1279 4 1/2 X 4 1/2 NRP CLR HA
1 STOREROOM LOCK 3480 ARC SFIC US26D HA
1 SFIC CORE 3969 US26D HA
1 CLOSER 5100 5124-PSHOSA ALM HA
1 KICK PLATE 190S 10" X 2" LDW CSK US32D HA
3" = 1'-0"8TYP. INTERIOR DOOR HEAD
3" = 1'-0"9TYP. INTERIOR DOOR JAMB
3" = 1'-0"10TYP. INTERIOR DOOR SILL
3" = 1'-0"3SLIP TRACK
3" = 1'-0"4PARTITION @ ROOF
3" = 1'-0"5PARTITION @ FLOOR
1/4" = 1'-0"1INTERIOR ELEVATION
ARCHITECTURAL KEYNOTES
## DESCRIPTION
5.01 NEW INTERIOR NON-LOAD-BEARING FULL-HEIGHT PARTITION: 6" 25 GA. MTL STUDS AT
16" O.C. MAX WITH ACOUSTIC BATT INSULATION FULL DEPTH OF STUD & 5/8" GYP. BD.
BOTH SIDES
8.01 NEW INTERIOR 3'-0" W X 8'-0" H DOOR & FRAME: 1 3/4" SCW WOOD WITH WOOD VNR
FINISH & PAINTED H.M. FRAME TO MATCH EXISTING ADJACENT DOORS.
9.01 ADJUST EXISTING FLOOR FINISH AT NEW PARTITION AS REQUIRED; PROVIDE NEW
WALL BASE AT BOTH SIDES OF WALL TO MATCH EXISTING ADJACENT (MANUF: BURKE,
PRODUCT: RUBBER MYTE TP, COLOR: ROCKY 660, HEIGHT: 2.5" - VERIFY)
9.02 PROVIDE NEW PAINTED FINISH AT BOTH SIDES OF NEW PARTITION TO MATCH
EXISTING ADJACENT (MANUF: SHERWIN WILLIAMS, COLOR: SW7022 ALPACA - VERIFY)
23.02 NEW WALL-MOUNTED TRANSFER GRILLE PER MECHANICAL - INSTALL SOUND BOOT
AND PROVIDE ACOUSTICAL CAULKING AT ALL PENETRATIONS. PAINT DEVICE IN
COMPLETE TO MATCH ADJ. WALL FINISH
3" = 1'-0"11ASSISTIVE LISTENING SIGNAGE
3" = 1'-0"12MAX OCCUPANCY SIGNAGE
3" = 1'-0"13TACTILE EXIT SIGNAGE
1/2" = 1'-0"14SIGN MOUNTING
12" = 1'-0"15SIGNAGE NOTES
2909 S Daimler St
4/16/2025
YES NO
INSTRUCTIONS:
ORAN GE COUNTY FI RE AUTHORI TY
Plan Submittal Criteria
COMMERCIAL projects, MULTIFAMILY RESIDENTIAL projects
and RESIDENTIAL TRACT developments
·Fill in the project/business address and provide a brief description of the scope of work and type of business operation that will take place.
·Answer questions 1 through 10, read and initial items 11 and 12, then complete and sign the certification section.
·If you answer: - “YES” to any part of questions 1 through 10, submit the type of plan indicated in italics to OCFA.
·In some cases, other plan types not indicated herein may also be necessary depending on specific conditions or operations.
·Visit www.ocfa.org for submittal information and locations. If you need assistance in filling out this form or have questions regarding
requirements for review, please contact OCFA at 714-573-6108 or visit us at 1 Fire Authority Road, Irvine, CA 92602.
Address Suite City
Project Scope/Business Description
1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes to roadways,
curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates? Construction within
300 feet of an active or proposed oil well? Fire Master Plan (PR145)
2. Property is adjacent to a wildland area or non-irrigated native vegetation?
Fire Master Plan (PR145); a Fuel Modification Plan may also be required. (PR120, PR124)
3. Located in or < 100’ from a Division of Oil, Gas, and Geothermal Resources (DOGGR) field boundary, < 300’ from
an oil/gas seep, or < 1000’ from a landfill? Methane Work Plan. (PR170)
4. Installation/modification/repair of underground piping, backflow preventers, or fire department connections serving
private fire hydrant/sprinkler/standpipe systems? Underground Plan. (PR470, PR475)
5. Drinking/dining/recreation/meetings/training/religious functions or other gatherings in a room > 750 sq.ft. (> 1,000
sq.ft. for training/adulteducation) or > 49 people? Healthcare/outpatient services for > 5 people who may be unable
to immediately evacuate without assistance? Education for children (academic tutoring for ages 5+ is exempt unless
classified as an E occupancy by the Building Official)? Adult/child daycare? 24-hour care/supervision? Incarceration
or restraint? Hotel/apartment or residential facility with 3+ units and 3+ stories (3-story townhouses/rowhouses
where an independent direct exit to grade is provided for dwelling are exempt)? Congregate housing/dormitories
with 17+ people? High-rise structure (55+ feet to highest occupied floor level)? Architectural Plan (PR200-PR285)
6. Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a card,
button, or similar action to open a door in the direction of exit travel? Architectural, Sprinkler, and/or Alarm Plan
depending on the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR500-PR520)
7. Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
industrial/commercial refrigeration systems; compressed gasses; tanks for cryogenic or flammable/combustible
liquids; vapor recovery; smoke control; battery back-up/charging systems (> 50 gal. electrolyte, > 1,000 lb. lithium
ion); welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?
Special Equipment Plan (PR315, PR340-PR382)
8. Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
maintenance/repair? Cabinetry/woodworking/finishing facility? Chem Class & floor plan (full architectural plan if
H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
9. Storage or merchandizing areas in excess of 500 sq. ft. where items are located higher than 12’ (6’ for high-hazard
commodities, plastic, rubber, foam, etc.)? High-piled Storage Plan (PR330)
10. Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a
commercial cooking hood? Hood & Duct Extinguishing System, not just the hood mechanical plan. (PR335)
Initial each of the following two items indicating that you have read and understand the statement:
11.*Sprinklers/Alarms: Consult Building/Fire Codes and ordinances to determine sprinkler/alarm requirements; if a system is
required, plans shall be submitted for OCFA review. Existing buildings undergoing remodel must be evaluated by a licensed
Initials contractor to determine if modification is needed; if so, contractor shall submit plans prior to making modifications.
12. Fire Hazard Severity Zone: Consult maps available at building department or on OCFA website to determine if your site is located
in a FHSZ. Buildings in a FHSZ may be subject to special construction requirements detailed in CBC Chapter 7A or CRC R327—
Initials the building department will determine specific requirements.
I certify under penalty of perjury under the laws of the State of California that the above is true:
Print Name Signature
Phone Number ( )Date / /
Building Department: If you have verified that all of the questions have been answered accurately as “NO”, and the project does not otherwise require OCFA
review of sprinkler or alarm plans*, then you may accept this signed form as a written release that OCFA review is not required. Should you still require that the
applicant have plans approved by OCFA, please initial here or attach an OCFA referral form and have the applicant submit the form along with the
appropriate plans and fees for OCFA review. 10-08-14 EE
COM
SM
SM
2909 S Daimler St
4/16/2025
O R A N G E C O U N T Y F I R E A U T H O R I T Y
Plan Referral Form
Required for OCFA to review plans upon the request of the Building Department when
the answers on the Plan Submittal Criteria Form (on the reverse) are all “No”.
City / County Official Requesting Review:
City / County Reference #: Date: __________________________________
City / County: _____________________________________ E-Mail: __________________________________
Contact Name: _____________________________________ Phone #: _________________________________
Title: _____________________________________
** Have the applicant complete and sign the OCFA Plan Submittal Criteria Form on the reverse of this form. **
Reason(s) for Review:
Please describe why OCFA Plan Review is or may be required by the City/County :
OCFA COMMENTS:
No further action required on this specific plan type, based
on information provided on: ____/______/______.
Project to be taken in for OCFA Review.
Other:
Name: _________________________________________
Contact #: ______________________________________ Date: _________________________________
OCFA Authorization
Updated: 06/02/2020 rs
2909 S Daimler St
4/16/2025