HomeMy WebLinkAbout2918 S Rita Way - 20179858- DL - PlanSHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. E-1 Conduit and Conductor Schedule~(75°C Copper Column) Tag Description Wire Gauge # of Conductors Conduit Type Conduit Size 1 PV WIRES 10 AWG 2 N/A - Free Air N/A - Free Air 1 Bare Copper Ground (EGC/GEC) 6 AWG 1 N/A - Free Air N/A - Free Air 2 THWN-2 10 AWG 4(2-V+,2-V-)EMT 3/4" 2 THWN-2 - Ground 8 AWG 1 EMT 3/4" Inverter Ratings Inverter Make/Model TIGO EI TSI-7.6K-US Max DC Volt Rating 600V Max Continuous Output Power 7600W Max Nominal Voltage 240V Max AC Current 32A Max OCPD Rating 40A DESIGN TEMPERATURES ASHRAE EXTREME LOW -2°C ASHRAE 2% HIGH 38°C PV Module Ratings @ STC Module Make/Model SOLAREVER SE-182*91-410M-108(410W) MODULE Max Power-Point Current (Imp)13.08A Max Power-Point Voltage (Vmp)31.35V Open-Circuit Voltage (Voc)37.12V Short-Circuit Current (Isc)13.96A Max Series Fuse (OCPD)25A Nominal Maximum Power at STC (Pmax)410W Maximum System Voltage 1500V Voc Temperature Coefficient -0.29%/°C 3 THWN-2 8 AWG 3(1-L1,1-L2,1-N) EMT 3/4" 3 THWN-2 - Ground 8 AWG 1 EMT 3/4" SYSTEM SUMMARY BRANCH #1 MODULE SHORT CIRCUIT CURRENT NO. OF MODULES PER STRING ARRAY STC POWER ARRAY PTC POWER MAX AC CURRENT MAX AC POWER DERATED (CEC) AC POWER BRANCH #2 7790W 7273W 32A 7600W 7091.00W 13.96A 9 13.96A 10 4 THWN-2 4 AWG 3(1-L1,1-L2,1-N) EMT 1" 4 THWN-2 - Ground 8 AWG 1 EMT 1" 2918 S Rita Way - 2017985808/08/23 TIGO EI INVERTER PV INPUT BATTERY AC GRID MPPT2 MPPT3 + - G L1 L2 N G G (N) TIGO TSI-7.6K-US INVERTER (N) TIGO CCA KIT + RA485 LAN - E-STOP BUTTON ST R I N G # 1 EXISTING WIRE EXISTING WIRE (E)JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE ST R I N G # 2 (E)ABB PVI-4.2-OUTD-S-US-A INVERTER EXISTING WIRE (E)VISIBLE LOCKABLE 2 POLE 30A 'KNIFE' A/C DISCONNECT EXISTING WIRE G G G L1 N L2 N M POINT OF DELIVERY AND INTERCONNECTION 200A (E) GROUNDING ELECTRODE OR (UFER) NEW 240V/225A MAIN SERVICE PANEL SINGLE PHASE 70A BACKFEED BREAKER 4 MPPT1 M (E)PV PRODUCTION METER = = = = = = = = = = = = = = = = G 1 (N) JUNCTION BOX WITH IRREVERSIBLE GROUND SPLICE 2 (N) 19 SOLAREVER SE-182*91-410M-108(410W) WITH AN (19) TIGO TS4-A-O OPTIMIZERS ATTACHED TO THE BACK OF MODULE PV CIRCUIT 1: 9 MODULES/SERIES PV CIRCUIT 2: 10 MODULES/SERIES SPD (N) SURGE PROTECTION DEVICE TYPE 1 PV CIRCUIT 1: 8 MODULES/SERIES PV CIRCUIT 2: 8 MODULES/SERIES 25A 40A N (N)100A PV LOAD CENTER (E)16 RENESOLA JC-255M-24 (255W)/Bbh SOLAR MODULE NEW PV SYSTEM DC SYSTEM SIZE:- 7790W AC SYSTEM SIZE:- 7600W EXISTING PV SYSTEM DC SYSTEM SIZE:- 4080W AC SYSTEM SIZE:- 4200W COMBINED PV SYSTEM DC SYSTEM SIZE:- 11870 W AC SYSTEM SIZE:- 11800 W 3 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. E-2 METER # 32210001163 MAIN SERVICE PANEL 240/120V 1Ø, 3W MAIN BUSS: 225A MAX BREAKER SIZE: (225A X 1.2) - 200A = 70.0A 2918 S Rita Way - 2017985808/08/23 N 1. NOT ALL PLACARDS SHOWN MAY BE REQUIRED BY LOCAL AHJ. CONTRACTOR TO VERIFY PLACARD REQUIREMENTS WITH LOCAL AHJ BEFORE INSTALLATION. 2. ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF THE CALIFORNIA ELECTRICAL CODE 3. ALTERNATE POWER SOURCE PLACARD SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED LETTERS IN A CONTRASTING COLOR TO THE PLAQUE. THIS PLAQUE WILL BE ATTCHED BY POP RIVETS OR SCREWS OR OTHER APPROVED METHOD. 4. DIRECTORY PLACARD MARKING CONTENT AND FORMAT: RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HIEGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT. PERMANENT SIGNAGE NOTES: WARNING! DO NOT RELOCATE THIS OVERCURRENT DEVICE POWER SOURCE OUTPUT CONNECTION LABEL LOCATION: ADJACENT TO PV BREAKER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(2) ! DO NOT ADD LOADS PHOTOVOLTAIC SYSTEM COMBINER PANEL WARNING LABEL LOCATION: PHOTOVOLTAIC AC COMBINER (IF APPLICABLE). PER CODE(S): CEC 2022: 705.12(B)(3)(3) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY. LABEL LOCATION: ON OR NO MORE THAT 3 M (10 FT) FROM THE SERVICE DISCONNECTING MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. ELECTRICAL SHOCK HAZARD WARNING! LABEL LOCATION: INVERTER(S), AC DISCONNECT(S), AC COMBINER PANEL (IF APPLICABLE). PER CODE(S): CEC 2022: 690.13(B) & 706.15(C)(4) TERMINALS ON LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER, INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): CEC 2022: 690.56(C)(2), CFC 2022: 1204.5.3 MULTIPLE SOURCES OF POWER CAUTION: MAXIMUM AC OPERATING CURRENT: NOMINAL OPERATING AC VOLTAGE: 32.00 AMPS 240.0 VAC PHOTOVOLTAIC AC DISCONNECT LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): CEC 2022: 690.54 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. E-3 WARNING! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN SUPPLY OVERCURRENT DEVICE, SHALL NOT EXCEED AMPACITY OF BUSBAR. MAIN SERVICE PANEL & PV INVERTER. 29 1 8 S R I T A W A Y 2918 S Rita Way - 2017985808/08/23 05/31/2023 RE: Structural Certification for Installation of Residential Solar DANIEL GOMEZ:2918 S RITA WAY, SANTA ANA, CA 92704 Attn: To Whom It May Concern Design Criteria Code 2022 California Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 110 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf If you have any questions on the above, please do not hesitate to call. Sincerely, Eugene Munyanziza, P.E.Signed 05/31/2023 EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition shingle roofing over roof plywood supported by 2X4 Trusses at 24 inches. The slope of the roof was approximated to be 43 degrees. After review of the field observation data and based on our structural capacity calculation, the existing roof framing has been determined to be adequate to support the imposed loads without structural upgrades. Contractor shall verify that existing framing is consistent with the described above before install. Should they find any discrepancies, a written approval from SEOR is mandatory before proceeding with install. Capacity calculations were done in accordance with applicable building codes. projects@evengineersnet.com http://www.evengineersnet.com 2918 S Rita Way - 2017985808/08/23 Structural Letter for PV Installation Date: 05/31/2023 Job Address: 2918 S RITA WAY SANTA ANA, CA 92704 Job Name: DANIEL GOMEZ Job Number: 230531DG Scope of Work Table of Content Sheet 2 Cover 3 Attachment Uplift checks 4 Roof Framing Check 5 Seismic Check and Scope of work Engineering Calculations Summary Code 2022 California Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 110 mph Exposure C References NDS for Wood Construction Sincerely, Signed 05/31/2023 Eugene Munyanziza, P.E. EV Engineering, LLC projects@evengineersnet.com http://www.evengineersnet.com Exp: 06/30/2024 This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. projects@evengineersnet.com http://www.evengineersnet.com 2918 S Rita Way - 2017985808/08/23 Wind Load Cont. 110 mph ASCE 7-16 Figure 26.5-1B C 1.0 ASCE 7-16 Sec 26.8.2 0.85 ASCE 7-16 Table 26.10-1 0.85 ASCE 7-16 Table 26.6-1 1.00 ASCE 7-16 Table 26.9-1 22.35 psf 43.0 Degrees 1.5 Conservatively assuming all exposed 0.8 conservatively assuming 10 ft2 effective area Uplift (W)Zone(1,2e,2r) Zone(2n) Zone(3r)Zone(3e) Fig. 30-3-2 GCp=-1.1 -1.1 -1.45 -1.8 Eq. 29.4-7 P=qh(GCp)(γE)(γa)=-29.50 -29.50 -38.89 -48.27 GCp=0.9 Figure 30.3-2 P=qh(GCp)(γE)(γa)=9.90 Equation 29.4-7 Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachment max. spacing= 6 ft 5/16" Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A - NDS 2.5 in DFL Assumed Prying Coefficient 1.4 Allowable Capacity= 760 lbs Zone Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1,2e,2r) 6 16.5 132.0 212.9 Zone(2n) 6 16.5 132.0 212.9 Zone(3r) 6 16.5 170.1 212.9 Zone(3e) 6 16.5 208.2 212.9 Conservative Max= 208.2 < 760 CONNECTION IS OK 2. Embedment is measured from the top of the framing member to the tapered tip of a lag screw. Embedment in sheading or other material does not count. II V= Exposure = 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs γE= γa= KZt = qh= 0.00256KzKztKdKeV2 = Pitch = Lag Screw Penetration Risk Category = KZ = Kd = Ke = projects@evengineersnet.com http://www.evengineersnet.com 2918 S Rita Way - 2017985808/08/23 Vertical Load Resisting System Design Roof Framing Trusses Snow Load Fully Exposed pg= 0 psf Ct = 1.1 Ce = 0.9 Is = 1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf Conservatively (Cs=1) 0 plf Max Length, L = 8.0 ft (Rafter maximum Allowable Horizontal Span) Tributary Width, WT = 24 in Dr = 10 psf 20 plf PvDL = 3 psf 18 plf Load Case: DL+0.75(0.6W+S) 0.75(Pnet+Ps)+ Ppvcos(θ)+PDL= 47 plf Mdown= 250 lb-ft Mallowable = Sx x Fb' (wind)= 456 lb-ft > 250 lb-ft OK Load Case: DL+S Ps+ Ppvcos(θ)+PDL= 38 plf Mdown= 203 lb-ft Mallowable = Sx x Fb' (wind)= 456 lb-ft > 203 lb-ft OK Load Case: DL+0.6W Pnet+ Ppvcos(θ)+PDL= 49.9 plf Max Moment, Mu= 266 lb-ft Mallowable = Sx x Fb' (wind)= 634 lb-ft > 266 lb-ft OK Pv max Shear= 212.9 lbs Shear, Vu=wL/2+Pv Point Load = 365 lbs Max Shear, Vu=wL/2+Pv Point Load = 365 lb Member Capacity DF-L No.2 2X4 CL CF C i Cr KF φ λ Fb = 900 psi 1.0 1.5 1.0 1.15 2.54 0.85 0.8 1553 psi Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E = 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin = 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 3.5 in Width, b = 1.5 in Cross-Sectonal Area, A = 5.25 in2 Moment of Inertia, Ixx = 5.35938 in4 Section Modulus, Sxx = 3.0625 in3 Allowable Moment, Mall = Fb'Sxx = 396.2 lb-ft DCR=Mu/Mall = 0.55 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A = 630.0 lb DCR=Vu/Vall = 0.58 < 1 Satisfactory Design Value Adjusted Value projects@evengineersnet.com http://www.evengineersnet.com 2918 S Rita Way - 2017985808/08/23 Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 33% Dpv and Racking 3 psf Average Total Dead Load 11.0 psf Increase in Dead Load 3.9%OK Limits of Scope of Work and Liability The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required. We have based our structural capacity determination on information in pictures and a drawing set titled PV plans -DANIEL GOMEZ. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this Structure's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures. projects@evengineersnet.com http://www.evengineersnet.com 2918 S Rita Way - 2017985808/08/23 N 3' 1'-6" 3' SCALE: 3/32" = 1'-0" PV SYSTEM SITE PLAN PV SYSTEM SIZE: 7.79 kW DC LEGEND CONSTRUCTION NOTES NEW SOLAR PANELS 29 1 8 S R I T A W A Y SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. PV-1 M PV INTERCONNECTION POINT. LOCATION OF METER MAIN COMBO, PV LOAD CENTER & STRING INVERTER MOUNTED ON EXTERIOR WALL OF A SINGLE FAMILY RESIDENCE. INV LOCATION OF EXISTING STRING INVERTER PV PRODUCTION METER & AC DISCONNECT ACD AC DISCONNECT LC PV LOAD CENTER PM PV PRODUCTION METER PROPERTY LINE DRIVEWAY (19) SOLAREVER SE-182*91-410M-108(410W) MODULES WITH A TIGO TS4-A-O OPTIMIZER ATTACHED TO THE BACK OF EACH MODULES MOUNTED ON COMP SHINGLE ROOF LOCATION OF "RAPID SHUTDOWN"DISCONNECT NEC 690.12 M METER MAIN COMBO INV STRING INVERTER Roof Azimuth: 90° Roof Tilt: 43° Roof Section1 CAL-FIRE ROOF LADDER ACCESS POINT PR O P E R T Y LI NE 1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE. 2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609 TO WITHSTAND A BASIC WIND SPEED OF 110 MPH (3 SECOND GUST), WIND EXPOSURE C. 3. THE ROOF MEMBERS ARE 2 "X 4" TRUSSES AT 24" ON CENTER. CONNECTION TO STRUCTURE SHALL NOT BE WITHIN 11" OF NAILING PLATES. 4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 7/8" ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND RACKING). 6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (CRC R324.6, CBC 3111.3.4) 6.1. LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. 6.2. LOCATED AT STRONG POINTS OF CONSTRUCTION IN LOCATIONS WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS: TREES, WIRES, OR SIGNS. 7. SETBACKS AT RIDGES CAN BE REDUCED TO 18 INCHES IN COMPLIANCE WITH 2022 CFC/2021 IFC 1205.2.2.1 TOTAL PLAN VIEW AREA = 2534.85 SQFT TOTAL PV AREA FOR NEW SYSTEM =19(67.87 IN)(44.64 IN)/(144 IN^2) = 399.75 SQFT =(294.56 SQFT/ 2534.85 SQFT)100 = 11.62% TOTAL PV AREA FOR EXISTING SYSTEM =16(64.9 IN)(39.1 IN)/(144 IN^2) = 281.95 SQFT =(281.95 SQFT/ 2534.85 SQFT)100 = 11.12% TOTAL PV AREA FOR NEW AND EXISTING SYSTEM. (399.75+281.95) SQFT/ 2534.85 SQFT = 22.74% TOTAL PV AREA POPULATES 22.73% OF TOTAL PLAN VIEW AREA AND IS WITHIN THE 33% REQUIREMENT. PROPERTY LINE PROPERTY LINEPROPERTY LINE PR O P E R T Y LI NE PR O P E R T Y LINE PR O P E R T Y LI NE PM INVACD EXISTING SOLAR SYSTEM CAL-FIRE ROOF LADDER ACCESS POINT ROOF OBSTRUCTIONS LC Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23 6' 6' 6' 6' 6' 6' N SCALE: 3/16" = 1'-0" PV SYSTEM MOUNTING DETAILS EXISTING COMP SHINGLE ROOF UNIRAC FLASHLOC MOUNT FOR COMP SHINGLE @ 72" O.C. MAX PROPOSED EVEREST CROSSRAIL RACKING PROPOSED SOLAREVER SE-182*91-410M-108(410W) PV SOLAR MODULES EXISTING 2 "X 4" ROOF TRUSSES @ 24"O.C. SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. PV-2 Roof Azimuth: 90° Roof Tilt: 43° Roof Section 1 Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23 RO O F S L O P E 910 10 6 21 7 PV-3 D5 20 11 1214 13 15 18 22 PV-3 D4 3 1 5 4 25 24 23 8 26 2 D4 DETAIL (TRANSVERSE) NOT TO SCALE D5 DETAIL (LONGITUDINAL) NOT TO SCALE D1 RACKING DETAIL (TRANSVERSE) NOT TO SCALE D3 RACKING DETAIL (TOP) NOT TO SCALE D2 RACKING DETAIL (LONGITUDINAL) NOT TO SCALE SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. 1. ROOF MATERIAL: COMP SHINGLE 2. ROOF STRUCTURE: TRUSSES 3. ATTACHMENT TYPE: UNIRAC FLASHLOC MOUNT 4. MODULE MANUFACTURER: SOLAREVER 5. MODULE MODEL: SE-182*91-410M-108(410W) 6. MODULE LENGTH: 67.87'' 7. MODULE WIDTH: 44.64" 8. MODULE WEIGHT: 47.4 LBS. 9. SEE SHEET S-1 FOR DIMENSION(S) 10. MIN. FIRE OFFSET: 18" 11. TRUSSES SPACING: 24" O.C. 12. TRUSSES SIZE: 2 "X 4" NOMINAL 13. LAG BOLT DIAMETER: 5/16 IN. 14. LAG BOLT EMBEDMENT: 2.5 IN. 15. TOTAL # OF ATTACHMENTS: 29 16. TOTAL AREA: 399.75 SQ. FT. 17. TOTAL WEIGHT: 900.60 LBS. 18. WEIGHT PER ATTACHMENT: 31.06 LBS. 19. DISTRIBUTED LOAD: 2.25 PSF 20. MAX. HORIZONTAL STANDOFF: 72 IN. 21. MAX. VERTICAL STANDOFF: LANDSCAPE: 26 IN., PORTRAIT: 43 IN. 22. STANDOFF STAGGERING: YES 23. RAIL MANUFACTURER AND MODEL (OR EQUIV.):EVEREST CROSSRAIL 24. RAIL WEIGHT: 0.436 PLF. 25. MAX. TRUSSES SPAN: 12 FT. 26. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX. PV-3 Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. S-1 Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. S-2 Signed: 05/31/2023 Structural Only Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. S-3 Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. S-4 Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. S-5 Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2 -1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 1053344 Solgen Construction, LLC Cole Farmer Permits@CoreEnergyGroup.com 559-462-6009 2918 S Rita Way, Santa Ana, CA 92704 06/08/2023 2918 S Rita Way - 2017985808/08/23 2918 S Rita Way - 2017985808/08/23 To whom it may concern, This letter serves to confirm I have chosen to have my system installed by Solgen Construction LLC. You have my express permission to move forward with the solar permit applied for by Solgen Construction LLC for my property at 2918 S Rita Way, Santa Ana, CA 92704. Thank you, Daniel Gomez DocuSign Envelope ID: FF38C3D8-4849-43AE-A6A4-6976B1471DFE 6/1/2023 2918 S Rita Way - 2017985808/08/23 DocuSign Envelope ID: FF38C3D8-4849-43AE-A6A4-6976B1471DFE 2918 S Rita Way - 2017985808/08/23 Certificate Of Completion Envelope Id: FF38C3D8484943AEA6A46976B1471DFE Status: Completed Subject: Complete with DocuSign: Daniel Gomez - Authorization Letter.pdf Source Envelope: Document Pages: 2 Signatures: 1 Envelope Originator: Certificate Pages: 5 Initials: 0 Core Energy Group AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-08:00) Pacific Time (US & Canada) 727 Eagle Pass North Salt Lake, UT 84054 proposals@coreenergygroup.com IP Address: 71.41.39.59 Record Tracking Status: Original 6/1/2023 8:47:05 AM Holder: Core Energy Group proposals@coreenergygroup.com Location: DocuSign Signer Events Signature Timestamp Daniel Gomez dgomez1188@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 174.195.133.198 Signed using mobile Sent: 6/1/2023 8:51:59 AM Viewed: 6/1/2023 9:01:07 AM Signed: 6/1/2023 9:01:26 AM Electronic Record and Signature Disclosure: Accepted: 6/1/2023 9:01:07 AM ID: ff0ac250-f0ad-431c-96b0-93ce08433600 In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Core Permits permits@coreenergygroup.com Mr. Security Level: Email, Account Authentication (None) Sent: 6/1/2023 9:01:27 AM Viewed: 6/1/2023 9:01:59 AM Electronic Record and Signature Disclosure: Accepted: 5/26/2023 9:28:20 AM ID: 4355994f-e804-4400-8c18-5af9a07dd306 Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 6/1/2023 8:51:59 AM Certified Delivered Security Checked 6/1/2023 9:01:07 AM Signing Complete Security Checked 6/1/2023 9:01:26 AM Completed Security Checked 6/1/2023 9:01:27 AM 2918 S Rita Way - 2017985808/08/23 Payment Events Status Timestamps Electronic Record and Signature Disclosure 2918 S Rita Way - 2017985808/08/23 ELECTRONIC RECORD AND SIGNATURE DISCLOSURE From time to time, Solgen Construction LLC (we, us or Company) may be required by law to provide to you certain written notices or disclosures. Described below are the terms and conditions for providing to you such notices and disclosures electronically through the DocuSign system. Please read the information below carefully and thoroughly, and if you can access this information electronically to your satisfaction and agree to this Electronic Record and Signature Disclosure (ERSD), please confirm your agreement by selecting the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. Getting paper copies At any time, you may request from us a paper copy of any record provided or made available electronically to you by us. You will have the ability to download and print documents we send to you through the DocuSign system during and immediately after the signing session and, if you elect to create a DocuSign account, you may access the docume nts for a limited period of time (usually 30 days) after such documents are first sent to you. After such time, if you wish for us to send you paper copies of any such documents from our office to you, you will be charged a $0.00 per-page fee. You may request delivery of such paper copies from us by following the procedure described below. Withdrawing your consent If you decide to receive notices and disclosures from us electronically, you may at any time change your mind and tell us that thereafter you want to receive required notices and disclosures only in paper format. How you must inform us of your decision to receive future notices and disclosure in paper format and withdraw your consent to receive notices and disclosures electronically is described below. Consequences of changing your mind If you elect to receive required notices and disclosures only in paper format, it will slow the speed at which we can complete certain steps in transactions with you and delivering services to you because we will need first to send the required notices or disclosures to you in paper format, and then wait until we receive back from you your acknowledgment of your receipt of such paper notices or disclosures. Further, you will no longer be able to use the DocuSign s ystem to receive required notices and consents electronically from us or to sign electronically documents from us. All notices and disclosures will be sent to you electronically Electronic Record and Signature Disclosure created on: 2/16/2023 3:39:07 PM Parties agreed to: Daniel Gomez, Core Permits 2918 S Rita Way - 2017985808/08/23 Unless you tell us otherwise in accordance with the procedures described herein, we will provide electronically to you through the DocuSign system all required notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you during the course of our relationship with you. To reduce the chance of you inadvertently not receiving any notice or disclosure, we prefer to provide all of the required notices and disclosures to you by the same method and to the same address that you have given us. Thus, you can receive all the disclosures and notices electronically or in paper format through the paper mail delivery system. If you do not agree with this process, please let us know as described below. Please also see the paragraph immediately above that describes the consequences of your electing not to receive delivery of the notices and disclosures electronically from us. How to contact Solgen Construction LLC: You may contact us to let us know of your changes as to how we may contact you electronically, to request paper copies of certain information from us, and to withdraw your prior consent to receive notices and disclosures electronically as follows: To contact us by email send messages to: proposals@solgen.co To advise Solgen Construction LLC of your new email address To let us know of a change in your email address where we should send notices and disclosures electronically to you, you must send an email message to us at proposals@solgen.co and in the body of such request you must state: your previous email address, your new email address. We do not require any other information from you to change your email address. If you created a DocuSign account, you may update it with your new email address through your account preferences. To request paper copies from Solgen Construction LLC To request delivery from us of paper copies of the notices and disclosures previously provided by us to you electronically, you must send us an email to proposals@solgen.co and in the body of such request you must state your email address, full name, mailing address, and telephone number. We will bill you for any fees at that time, if any. To withdraw your consent with Solgen Construction LLC To inform us that you no longer wish to receive future notices and disclosures in electronic format you may: 2918 S Rita Way - 2017985808/08/23 i. decline to sign a document from within your signing session, and on the subsequent page, select the check-box indicating you wish to withdraw your consent, or you may; ii. send us an email to proposals@solgen.co and in the body of such request you must state your email, full name, mailing address, and telephone number. We do not need any other information from you to withdraw consent.. The consequences of your withdrawing consent for online documents will be that transactions may take a longer time to process.. Required hardware and software The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found here: https://support.docusign.com/guides/signer-guide- signing-system-requirements. Acknowledging your access and consent to receive and sign documents electronically To confirm to us that you can access this information electronically, which will be similar to other electronic notices and disclosures that we will provide to you, please confirm that you have read this ERSD, and (i) that you are able to print on paper or electronically save this ERSD for your future reference and access; or (ii) that you are able to email this ERSD to an email address where you will be able to print on paper or save it for your future reference and access. Further, if you consent to receiving notices and disclosures exclusively in electroni c format as described herein, then select the check-box next to ‘I agree to use electronic records and signatures’ before clicking ‘CONTINUE’ within the DocuSign system. By selecting the check-box next to ‘I agree to use electronic records and signatures’, you confirm that: You can access and read this Electronic Record and Signature Disclosure; and You can print on paper this Electronic Record and Signature Disclosure, or save or send this Electronic Record and Disclosure to a location where you can print it, for future reference and access; and Until or unless you notify Solgen Construction LLC as described above, you consent to receive exclusively through electronic means all notices, disclosures, authorizations, acknowledgements, and other documents that are required to be provided or made available to you by Solgen Construction LLC during the course of your relationship with Solgen Construction LLC. 2918 S Rita Way - 20179858 08/08/23 GOMEZ RESIDENCE NEW PHOTOVOLTAIC SYSTEM PROJECT - 7.790 kW DC / 7.600 kW AC SHEET # T-1 T-2 PV-1 PV-2 PV-3 E-1 E-2 E-3 S-1 S-2 S-3 S-4 S-5 SHEET NAME COVER SHEET PLAN NOTES SITE PLAN LAYOUT ATTACHMENT DETAILS MOUNTING DETAILS ELECTRICAL CALCULATION ELECTRICAL DIAGRAM WARNING LABELS SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET SPEC SHEET COORDINATES: 33.708002, -117.889902 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. T-1 AERIAL VIEW TYPE OF INTERCONNECTION: BACKFEED BREAKER IN THE MSP SCOPE OF WORK SYSTEM SIZE: STC: 19 X 410W = 7.790kW PTC: 19 X 382.78W = 7.273kW (19)SOLAREVER SE-182*91-410M-108(410W) MODULES (1)TIGO EI TSI-7.6K-US INVERTER (19)TIGO TS4-A-O PV OPTIMIZERS (1)100A PV LOAD CENTER MSP UPGRADE: YES, TO 225A/200A MAIN BREAKER DERATE: NO RACKING & MOUNTING PV ATTACHMENT TYPE: UNIRAC FLASHLOC MOUNT FOR COMP SHINGLE ROOF RACKING TYPE: EVEREST CROSSRAIL- ROOF MOUNT RACKING HARDWARE PROJECT INFORMATION PROPERTY OWNER NAME: DANIEL GOMEZ CONTRACTOR NAME:SOLGEN CONSTRUCTION PHONE:(559)442-9887 DESIGN SPECIFICATIONS OCCUPANCY: R-3 CONSTRUCTION TYPE: SINGLE FAMILY RESIDENCE ZONING: RESIDENTIAL GROUND SNOW LOAD: 0 PSF WIND EXPOSURE: C WIND SPEED: 110 MPH APPLICABLE CODES & STANDARDS 2022 CALIFORNIA RESIDENTIAL CODE (CRC) 2022 CALIFORNIA BUILDING CODE (CBC) 2022 CALIFORNIA MECHANICAL CODE (CMC) 2022 CALIFORNIA ELECTRICAL CODE (CEC) 2022 CALIFORNIA PLUMBING CODE (CPC) 2022 CALIFORNIA ENERGY CODE (ENERGY) 2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN) 2020 NATIONAL ELECTRICAL CODE (NEC) 2022 CALIFORNIA FIRE CODE (CFC) Signed: 05/31/2023 Structural Only NEW PV SYSTEM DC SYSTEM SIZE:- 7790W AC SYSTEM SIZE:- 7600W EXISTING PV SYSTEM DC SYSTEM SIZE:- 4080W AC SYSTEM SIZE:- 4200W COMBINED PV SYSTEM DC SYSTEM SIZE:- 11870 W AC SYSTEM SIZE:- 11800 W The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101115408 Elect# 20179858 MS Issued 08/08/23 2918 S Rita Way - 2017985808/08/23 SHEET CONTRACTOR SOLGEN CONSTRUCTION LLC. 2918 S RITA WAY, SANTA ANA, CA 92704 APN:14024222 DATE:6/20/2023 GOMEZ RESIDENCE License#: C-10 1053344 ADDRESS: 2072 N MAIN ST FL 2, LOGAN UT 84341-1993 CSLB#: 1053344 DESIGNER: OSD CORE ENERGY GROUP. T-2 1.1. PROJECT NOTES: 1.2. THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE 2022 CALIFORNIA ELECTRICAL CODE (CEC) ARTICLE 690, ALL MANUFACTURER’S LISTING AND INSTALLATION INSTRUCTIONS, AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY HAVING JURISDICTION’S (AHJ) APPLICABLE CODES. 1.3. THE UTILITY INTERCONNECTION APPLICATION MUST BE APPROVED AND PV SYSTEM INSPECTED PRIOR TO PARALLEL OPERATION 1.4. GROUND FAULT DETECTION AND INTERRUPTION (GFDI) DEVICE IS INTEGRATED WITH THE MICROINVERTER IN ACCORDANCE WITH 2022 CEC 690.41(B) 1.5. ALL PV SYSTEM COMPONENTS; MODULES, UTILITY-INTERACTIVE INVERTERS, AND SOURCE CIRCUIT COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN PHOTOVOLTAIC SYSTEMS AS REQUIRED BY 2022 CEC 690.4 PV MODULES: UL1703, IEC61730, AND IEC61215, AND NFPA 70 CLASS C FIRE INVERTERS: UL 1741 CERTIFIED, IEEE 1547, 929, 519 COMBINER BOX(ES): UL 1703 OR UL 1741 ACCESSORY 1.6. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR VOC. IF UNAVAILABLE, MAX DC VOLTAGE CALCULATED ACCORDING TO 2022 CEC 690.7. 1.7. ALL INVERTERS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AND SOURCE CIRCUIT COMBINERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4 (D). SHALL BE INSTALLED ACCORDING TO ANY INSTRUCTIONS FROM LISTING OR LABELING [ 2022 CEC 110.3]. 1.8. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV RESISTANT. ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC AND AHJ. 1.9. SCOPE OF WORK: 1.10. PRIME CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND SPECIFICATIONS OF THE GRID-TIED PHOTOVOLTAIC SYSTEM RETROFIT. PRIME CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTING EXISTING ONSITE REQUIREMENTS TO DESIGN, SPECIFY, AND INSTALL THE EXTERIOR ROOF-MOUNTED PORTION OF THE PHOTOVOLTAIC SYSTEMS DETAILED IN THIS DOCUMENT. 1.11. WORK INCLUDES: 1.12. PV ROOF ATTACHMENTS - UNIRAC FLASHLOC MOUNT FOR COMP SHINGLE ROOF 1.13. PV RACKING SYSTEM INSTALLATION - EVEREST CROSSRAIL ROOF MOUNT RACKING HARDWARE 1.14. PV MODULE AND INVERTER INSTALLATION - SOLAREVER SE-182*91-410M-108(410W) MODULES / TIGO EI TSI-7.6K-US INVERTER 1.15. PV EQUIPMENT GROUNDING 1.16. PV SYSTEM WIRING TO A ROOF-MOUNTED JUNCTION BOX 1.17. PV LOAD CENTERS (IF INCLUDED) 1.18. PV METERING/MONITORING (IF INCLUDED) 1.19. PV DISCONNECTS 1.20. PV GROUNDING ELECTRODE & BONDING TO (E) GEC 1.21. PV FINAL COMMISSIONING 1.22. (E) ELECTRICAL EQUIPMENT RETROFIT FOR PV 1.23. SIGNAGE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE 1.24. SITE NOTES: 1.25. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 1.26. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERY. 1.27. THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 1.28. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION 2022 CEC 110.26. 1.29. ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. 1.30. EQUIPMENT LOCATIONS: 1.31. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY 2022 CEC 110.26. 1.32. WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY 2022 CEC 690.31 (A),(C) AND CEC TABLES 310.15 (B)(2)(A) AND 310.15 (B)(3)(C) 1.33. JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO 2022 CEC 690.34. 1.34. ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT . 1.35. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO 2022 CEC APPLICABLE CODES. 1.36. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. 1.37. STRUCTURAL NOTES: 1.38. RACKING SYSTEM 1.39. PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND 1.40. A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY/SUBARRAY, ACCORDING TO RAIL MANUFACTURER’S INSTRUCTIONS. 1.41. JUNCTION BOX WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED SEALED PER LOCAL REQUIREMENTS. 1.42. ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED WITH APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 1.43. ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 1.44. WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. 1.45. WIRING & CONDUIT NOTES: 1.46. ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 1.47. CONDUCTORS SIZED ACCORDING TO 2022 CEC 690.8, 2022 CEC 690.7. 1.48. VOLTAGE DROP LIMITED TO 1.5%. 1.49. DC WIRING LIMITED TO MODULE FOOTPRINT. MICROINVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY WITH SUITABLE WIRING CLIPS. 1.50. AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [2022 CEC 110.15 1.51. GROUNDING NOTES: 1.52. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 1.53. PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO 2022 CEC 690.43 AND MINIMUM 2022 CEC TABLE 250.122. 1.54. METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORDING WITH 2022 CEC 250.134 AND 2022 250.136(A). 1.55. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO CEC 690.45 AND MICROINVERTER MANUFACTURER'S INSTRUCTIONS. 1.56. EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 1.57. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 1.58. GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [2022 CEC 250.119] 1.59. THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH CEC 690.47 AND CEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO CEC 250, CEC 690.47 AND AHJ. 1.60. GROUND-FAULT DETECTION SHALL COMPLY WITH CEC 690.41 IN GENERAL AND CEC 690.41 (A)(1) SPECIFICALLY. 1.61. DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.62. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 1.63. DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 1.64. RAPID SHUTDOWN OF ENERGIZED CONDUCTORS BEYOND 1 FT OF PV ARRAY OR 5 FT INSIDE A BUILDING WITHIN 10 SECONDS. CONTROLLED CONDUCTORS ≤30V AND ≤240VA [CEC 690.12(B)]. LOCATION OF LABEL ACCORDING TO AHJ 1.65. ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO CEC 690.8, 690.9, AND 240. 1.66. EQUIPMENT THAT IS LISTED, LABELED, OR BOTH SHALL BE INSTALLED AND USED IN ACCORDANCE WITH ANY INSTRUCTIONS INCLUDED IN THE LISTING OR LABELING. CEC 110.3(B). 1.67. IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO CEC 690.11 AND UL1699B. 1.68. INTERCONNECTION NOTES: 1.69. LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [2022 CEC 705.12] 1.70. THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS INPUT MAY NOT EXCEED 120% OF BUSBAR RATING [2022 CEC 705.12(B)(3)(2)]. 1.71. WHEN SUM OF THE PV SOURCES EQUALS >100% OF BUSBAR RATING, PV DEDICATED BACKFFED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [2022 CEC 705.12(B)(3)(2)]. 1.72. AT MULTIPLE PV OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO 2022 CEC 705.12 (B)(3)(3). 1.73. SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO 2022 CEC 705.11 WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH 2022 CEC 230.42 1.74. BACKFEEDING BREAKER FOR UTILITY-INTERACTIVE INVERTER OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [2022 CEC 705.12(E)]. Signed: 05/31/2023 Structural Only 2918 S Rita Way - 2017985808/08/23