HomeMy WebLinkAbout3114 S Rita Way - PlanE1 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 ABBREVIATIONS AMPERE ALTERNATING CURRENT AUTHORITY HAVING JURISDICTION BUILDING CONCRETE COMBINER BOX CALIFORNIA ELECTRICAL CODE COPPER DISTRIBUTION PANEL DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR (EXISTING) FIELD VERIFIED GALVANIZED GROUNDING ELECTRODE CONDUCTOR GROUND HOT DIPPED GALVANIZED CURRENT CURRENT AT MAX POWER INVERTER SHORT CIRCUIT CURRENT KILOVOLT AMPERE KILOWATT LOAD BEARING WALL MINIMUM MAIN CIRCUIT BREAKER MAIN SERVICE PANEL (NEW) NEMA 3R, RAINTIGHT OUTSIDE RATED NATIONAL ELECTRICAL CODE NOT TO SCALE ON CENTER OVERCURRENT PROTECTION DEVICE POLES -BREAKER POLES- PROPERTY LINES PHOTOVOLTAIC POLYVINYL CHLORIDE ROOF RAFTER SOLID BARE COPPER SOLAR PLANE SUBPANEL SCHEDULE STAINLESS STEEL PRACTICAL TESTING CONDITIONS SOLAR WATER HEATER TYPICAL UNLESS NOTED OTHERWISE VOLT VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT WATT A AC AHJ BLDG CONC CB CEC CU DP DC EGC (E) FV GALV GEC GND HDG I Imp INVT Isc kVA kW LBW MIN. MCB MSP (N) N3R NEC NTS OC OCPD P PL PV PVC RR SBC SP SPL SCH SS PTC SWH TYP UNO V Vmp Voc W SHEET INDEX APPLICABLE CODES AND STANDARDS VICINITY MAP N SCOPE OF WORK ·2022 CBC ·2022 CRC ·2022 CEC ·2022 CMC ·2022 CPC ·2022 CFC ·2022 CEBC · 2022 BUILDING ENERGY EFFICIENCY STANDARDS ·AUTHORITY HAVING JURISDICTION ·CURRENT LOCAL FIRE CODE 1. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 2. EQUIPMENT. INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN PHOTOVOLTAIC POWER SYSTEMS SHALL BE IDENTIFIED AND LISTED FOR THE APPLICATION. [CEC 690.4(B)] 3. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND NON ROOF SWITCHES. ROOF SWITCHES TO BE NEMA 4 RATED. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 5. PROTECTION DEVICES FOR PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS ALSO CONNECTED TO SOURCES HAVING SIGNIFICANTLY HIGHER CURRENT AVAILABILITY (E.G., PARALLEL STRINGS OF MODULES, UTILITY POWER), SHALL BE PROTECTED AT THE SOURCE FROM OVERCURRENT. [CEC 690.9(A)] 6. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS. [CEC 690.12] 7. THE UTILITY INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. [CEC 705.40] 8. ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT. [CEC 310.10(D)(1)] 9. THE MODULE CONDUCTORS MUST BE TYPE USE-2 OR LISTED FOR PHOTOVOLTAIC (PV) WIRE. [CEC 690.31(C)] 10. ALL CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION. 11. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IDENTIFIED AS A CONTINUOUS WHITE FINISH. [CEC 200.6] 12. THE OUTPUT OF AN INTERCONNECTED ELECTRICAL POWER SOURCE SHALL BE PERMITTED TO BE CONNECTED TO THE LOAD SIDE. INTERCONNECTING PROVISIONS FOR OTHER POWER SOURCES SHALL COMPLY WITH 705.12(B)(1) THROUGH 705.12(B)(3) 13. EACH SOURCE INTERCONNECTION OF ONE OR MORE POWER SOURCES INSTALLED IN ONE SYSTEM SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECTING MEANS. [CEC 705.12(A)] 14. THE SUM OF THE AMPERE RATING OF THE OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUSBAR OR CONDUCTOR SHALL NOT EXCEED 120% OF THE RATING OF BUSBAR OR CONDUCTOR. [CEC 705.12(B)(3)(2)] 15. A CONNECTION AT EITHER END, BUT NOT BOTH ENDS, OF A CENTER-FED PANEL BOARD IN DWELLINGS SHALL BE PERMITTED WHERE THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR DOES NOT EXCEED 120 PERCENT OF THE CURRENT RATING OF THE BUSBAR. [CEC 705.12(B)(3)(4)] 16. EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. [CEC 705.12(C)] 17. CIRCUIT BREAKER, IF BACKFED, SHALL BE SUITABLE FOR SUCH OPERATION. [CEC 705.12(D)] 18. TO MINIMIZE OVERHEATING OF THE BUSBAR IN PANELBOARD, THE PANELBOARD MAIN CIRCUIT BREAKER AND THE PV POWER SOURCE CIRCUIT BREAKER SHALL BE PHYSICALLY LOCATED AT THE OPPOSITE END OF THE BUSBAR. 19. ALL THE CEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT INSPECTOR. 20. WHERE PV SYSTEM DC CIRCUIT'S RUN INSIDE A BUILDING, THEY SHALL BE CONTAINED IN METAL RACEWAYS TYPE MC METAL CLAD CABLE OR METAL ENCLOSURES FROM POINT OF PENETRATION OF THE SURFACE OF THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS. [CEC 690.31(D)] 21. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IS IN ACCORDANCE WITH CEC 110.14. 22. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30V DC OR 15V AC SHALL REQUIRE TOOL TO OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [CEC 690.33(C) & (D)] 23. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR. [CEC 250.120(C)] 24. EQUIPMENT GROUNDING CONDUCTOR FOR PV SYSTEM CIRCUITS SHALL BE SIZED IN ACCORDANCE WITH 250.122. [CEC 690.45] 25. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE MADE AS PERMITTED. [CEC 250.64(C)] 26. ALL SMOKE ALARMS, CARBON MONOXIDE ALARMS AND AUDIBLE NOTIFICATION DEVICES SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 217 AND UL 2034. THEY WILL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 720. [CRC 2019 R314 & R315] 27. SMOKE ALARMS AND CARBON MONOXIDE ALARMS WILL BE RETROFITTED INTO THE EXISTING DWELLING. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME, OTHERWISE, THE ALARMS MUST BE HARD WIRED AND INTERCONNECTED. GENERAL NOTES *ALL WORK TO COMPLY WITH ABOVE CODES * OCCUPANCY TYPE: R-3 * CONSTRUCTION TYPE: TYPE V-B * UNSPRINKLERED DWELLING INFO E1 - COVER SHEET E2 - SITE PLAN E7 - SINGLE LINE DIAGRAM E8 - ELECTRICAL NOTES E9's - SIGNAGE E5 - ROOF PLAN E6 - ATTACHMENT DETAIL (N) AC COMBINER(S) - - - - 27 - - - (N) INVERTER(S) (N) SOLAR MODULE(S) - ENPHASE IQ8M-72-2-US - HANWHA Q.PEAK DUO BLK ML-G10+ 400 27 1 125A ENPHASE IQ COMBINER 4/4C 1 125A/100A NCF (N) MAIN SERVICE PANEL MSP IS UPGRADED WITH 125A/100A NCF. Bldg permit #101114132 Elect permit #20178902 - Approved by M. Smith on 3/2/23 Issued on 3/10/23 ***The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown.*** 3114 S Rita Way - 2017890203/10/23 STRUCTURAL CALCULATIONS FOR GABRIELLA CARDOZA-FAVARATO 3114 S RITA WAY SANTA ANA CA 92704 ENGINEER: BWU Consultants, Inc 1168 San Gabriel Blvd #N Rosemead, CA 91770 3114 S Rita Way - 2017890203/10/23 DESIGN DATA 1. CODE: 2022 CALIFORNIA BUILDING CODE ASCE 7-16 2. MATERIAL STRENGTH CONCRETE: Fc’ = 2,500 PSI @ 28 DAYS CONCRETE REBAR: ASTM A615 GRADE 40 Fy = 40,000 PSI STEEL: (AISC 360) 13 EDITION STRUCTURAL SHAPES: ASTM A36 Fy = 36 KSI TUBING: STM A500 GRADE B Fy = 46 KSI PIPE: ASTM A53 TYPE E GRADE B Fy = 35 KSI WOOD: DOUGLAS FIR-LARCH ( 19% MAX. M.C. ) JOIST & RAFTER #2 GRADE Fb = 875 PSI Fv = 95 PSI E = 1.6 x 1,000,000 BEAM & HEADER (4X) #1 GRADE Fb = 1,000 PSI Fv = 95 PSI E = 1.7 x 1,000,000 (6X) #1 GRADE Fb = 1,000 PSI Fv = 85 PSI E = 1.7 x 1,000,000 POST (4X) #1 GRADE Fb = 1,000 PSI Fv = 95 PSI E = 1.6 x 1,000,000 (6X) #1 GRADE Fb = 1,000 PSI Fv = 85 PSI E = 1.7 x 1,000,000 STUD #2 GRADE Fb = 675 PSI Fv = 95 PSI E = 1.4 x 1,000,000 SELECT STRUCTURAL (6x, LARGE) Fb = 1,450PSI Fv = 95 PSI E = 1.9 x 1,000,000 MASONRY: CONCRETE BLOCK ASTM C90 Fm = 1500 PSI NO INSPECTION REQUIRED 3. SOIL REPORT: f’s= 1,500 PSF/ OR SEE SOILS REPORT 4. LATERAL ANALYSIS: A. SEISMIC LOAD W CV SSEE ATTACHED. B. WIND LOAD (SIMPLIFIED PROCEDURE) (130 mph) EXP “C” ULTIMATE 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 BWU Consultants, Inc. 1168 N. San Gabriel Blvd., #N Rosemead, CA. 91770 Tel: (626) 288-0708 Email: twengrs1168@gmail.com Date: D.L.SIZE: TILE ROOF'G 9 psf 18.0 SQ.FT. 1/2" PLYWD SHT'G 1.5 2x6 @ 24 O.C.1.1 RAFTER MISC 0.4 WEIGHT: D.L. = WT = 2.9#/SQ.FT. L.L. = (USE 3.0 #/SQ.FT.) T.L. = L:7'-0" MAX SPAN W:70.0 plf M:428.75 pf Sreq: 3.15 in³ R:245 lb Areq: 3.09 in² 2x6 RAFTER CAN CARRY SOLAR PANELS GRAVITY PER 2022 CALIFORNIA EXISTING BLDG CODE. PART 10. SECTION 502.4 & 503.3 27 x 3 x 18 =1458 lb 27960 lb 1458 / 27960 =5.2% (ROOF DL 12) x 2330 = (12+3+20) x 24/12 = (2022 CALIFORNIA BUILDING CODE) ASCE 7-16 EXIST'G ROOF LOAD'G (AS BUILT) SOLAR PANEL 35.0 psf 20.0 psf 12.0 psf 3114 S Rita Way - 2017890203/10/23 WIND LOAD (RISK CATEGORY III,IV) 130 MPH, EXP ”C” CHAP 26.10.2 - WIND LOAD COMPONENTS & CLADDING (C&C) qz= .00256 Kz Kzt Kd V2 I (26-10-1) Ht. z at the centroid of area Af = 10 ft Exp = Exposure coefficient Kz = 0.85 c (TABLE 26.8-1) Topography factor Kzt = 1.00 (FIGURE 26.8-1) Directionality factor Kd = 0.85 Wind Speed V = 130 mph Importance factor Iw = 1.00 qz = 0.00256 x 0.85 x 1.0 x 0.85 x (130)2 = 31.26 psf Gust Effect factor G = 0.85 Force coeff Cf = 1.31 Design wind pressure, F/Af = 31.26 x 0.85 x 1.31 = 34.81 psf ASCE 7-16 3114 S Rita Way - 2017890203/10/23 BWU Consultants, Inc. 1168 N. San Gabriel Blvd., #N Rosemead, CA. 91770 Tel: (626) 288-0708 Email: twengrs1168@gmail.com Date: UPLIFT / WITHDRAWAL FORCE FOR SOLAR PANEL STANDOFF / FAST JACK Vup= 34.81 lb/sq.ft SEISMIC PER 2022 CALIFORNIA EXISTING BLDG CODE. PART 10. SECTION 502.5 & 503.4 1458 lb / 27960 lb = 5.2% < 10.0% OK Vall = 274 x 2.5 = 685 lb > 196.7 lb OK 27 27 x 34.81 x 18 = 16917.66 lb 86 196.7 lb/lag screw NO. SOLAR PANELS UPLIFT FORCE SUPPORTS OF TILE HOOK/STANDOFF UNIT FORCE PER (5/16"ø) LAG SCREW O.K. USE 5/16"ø X 3 1/2" LONG STAINLESS STEEL LAG SCREW WITH MIN. 2 1/2" EMBED TO EXIST'G ROOF MEMBER. CAN RESIST WIND UPLIFT FORCE. LATERAL (2022 CALIFORNIA BUILDING CODE) WIND EXP "C", WIND SPEED: 130 mph (ASCE 7-16) 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 E1 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 11-09-2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 ABBREVIATIONS AMPERE ALTERNATING CURRENT AUTHORITY HAVING JURISDICTION BUILDING CONCRETE COMBINER BOX CALIFORNIA ELECTRICAL CODE COPPER DISTRIBUTION PANEL DIRECT CURRENT EQUIPMENT GROUNDING CONDUCTOR (EXISTING) FIELD VERIFIED GALVANIZED GROUNDING ELECTRODE CONDUCTOR GROUND HOT DIPPED GALVANIZED CURRENT CURRENT AT MAX POWER INVERTER SHORT CIRCUIT CURRENT KILOVOLT AMPERE KILOWATT LOAD BEARING WALL MINIMUM MAIN CIRCUIT BREAKER MAIN SERVICE PANEL (NEW) NEMA 3R, RAINTIGHT OUTSIDE RATED NATIONAL ELECTRICAL CODE NOT TO SCALE ON CENTER OVERCURRENT PROTECTION DEVICE POLES -BREAKER POLES- PROPERTY LINES PHOTOVOLTAIC POLYVINYL CHLORIDE ROOF RAFTER SOLID BARE COPPER SOLAR PLANE SUBPANEL SCHEDULE STAINLESS STEEL PRACTICAL TESTING CONDITIONS SOLAR WATER HEATER TYPICAL UNLESS NOTED OTHERWISE VOLT VOLTAGE AT MAX POWER VOLTAGE AT OPEN CIRCUIT WATT A AC AHJ BLDG CONC CB CEC CU DP DC EGC (E) FV GALV GEC GND HDG I Imp INVT Isc kVA kW LBW MIN. MCB MSP (N) N3R NEC NTS OC OCPD P PL PV PVC RR SBC SP SPL SCH SS PTC SWH TYP UNO V Vmp Voc W SHEET INDEX APPLICABLE CODES AND STANDARDS VICINITY MAP N SCOPE OF WORK ·2022 CBC ·2022 CRC ·2022 CEC ·2022 CMC ·2022 CPC ·2022 CFC ·2022 CEBC · 2022 BUILDING ENERGY EFFICIENCY STANDARDS ·AUTHORITY HAVING JURISDICTION ·CURRENT LOCAL FIRE CODE 1. EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS, VENTILATIONS INTAKE AIR OPENINGS SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. 2. EQUIPMENT. INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, AC PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS, AND CHARGE CONTROLLERS INTENDED FOR USE IN PHOTOVOLTAIC POWER SYSTEMS SHALL BE IDENTIFIED AND LISTED FOR THE APPLICATION. [CEC 690.4(B)] 3. ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED, INCLUDING ALL ROOF MOUNTED TRANSITION BOXES AND NON ROOF SWITCHES. ROOF SWITCHES TO BE NEMA 4 RATED. 4. ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH CEC ARTICLE 250. 5. PROTECTION DEVICES FOR PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS ALSO CONNECTED TO SOURCES HAVING SIGNIFICANTLY HIGHER CURRENT AVAILABILITY (E.G., PARALLEL STRINGS OF MODULES, UTILITY POWER), SHALL BE PROTECTED AT THE SOURCE FROM OVERCURRENT. [CEC 690.9(A)] 6. PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT CONTROLS SPECIFIC CONDUCTORS. [CEC 690.12] 7. THE UTILITY INTERACTIVE INVERTERS SHALL AUTOMATICALLY DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THE SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. [CEC 705.40] 8. ALL CONDUCTOR EXPOSED TO WEATHER SHALL BE LISTED AND IDENTIFIED FOR USE IN DIRECT SUNLIGHT. [CEC 310.10(D)(1)] 9. THE MODULE CONDUCTORS MUST BE TYPE USE-2 OR LISTED FOR PHOTOVOLTAIC (PV) WIRE. [CEC 690.31(C)] 10. ALL CONDUCTORS SHALL BE MARKED ON EACH END FOR UNIQUE IDENTIFICATION. 11. AN INSULATED GROUNDED CONDUCTOR OF 6 AWG OR SMALLER SHALL BE IDENTIFIED AS A CONTINUOUS WHITE FINISH. [CEC 200.6] 12. THE OUTPUT OF AN INTERCONNECTED ELECTRICAL POWER SOURCE SHALL BE PERMITTED TO BE CONNECTED TO THE LOAD SIDE. INTERCONNECTING PROVISIONS FOR OTHER POWER SOURCES SHALL COMPLY WITH 705.12(B)(1) THROUGH 705.12(B)(3) 13. EACH SOURCE INTERCONNECTION OF ONE OR MORE POWER SOURCES INSTALLED IN ONE SYSTEM SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE DISCONNECTING MEANS. [CEC 705.12(A)] 14. THE SUM OF THE AMPERE RATING OF THE OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO THE BUSBAR OR CONDUCTOR SHALL NOT EXCEED 120% OF THE RATING OF BUSBAR OR CONDUCTOR. [CEC 705.12(B)(3)(2)] 15. A CONNECTION AT EITHER END, BUT NOT BOTH ENDS, OF A CENTER-FED PANEL BOARD IN DWELLINGS SHALL BE PERMITTED WHERE THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR DOES NOT EXCEED 120 PERCENT OF THE CURRENT RATING OF THE BUSBAR. [CEC 705.12(B)(3)(4)] 16. EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. [CEC 705.12(C)] 17. CIRCUIT BREAKER, IF BACKFED, SHALL BE SUITABLE FOR SUCH OPERATION. [CEC 705.12(D)] 18. TO MINIMIZE OVERHEATING OF THE BUSBAR IN PANELBOARD, THE PANELBOARD MAIN CIRCUIT BREAKER AND THE PV POWER SOURCE CIRCUIT BREAKER SHALL BE PHYSICALLY LOCATED AT THE OPPOSITE END OF THE BUSBAR. 19. ALL THE CEC REQUIRED WARNING SIGNS, MARKINGS, AND LABELS SHALL BE POSTED ON EQUIPMENT AND DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT INSPECTOR. 20. WHERE PV SYSTEM DC CIRCUIT'S RUN INSIDE A BUILDING, THEY SHALL BE CONTAINED IN METAL RACEWAYS TYPE MC METAL CLAD CABLE OR METAL ENCLOSURES FROM POINT OF PENETRATION OF THE SURFACE OF THE BUILDING TO THE FIRST READILY ACCESSIBLE DISCONNECTING MEANS. [CEC 690.31(D)] 21. FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES OR CONNECTOR THAT ARE IS IN ACCORDANCE WITH CEC 110.14. 22. CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY ACCESSIBLE AND OPERATING AT OVER 30V DC OR 15V AC SHALL REQUIRE TOOL TO OPEN AND MARKED "DO NOT DISCONNECT UNDER LOAD" OR "NOT FOR CURRENT INTERRUPTING". [CEC 690.33(C) & (D)] 23. EQUIPMENT GROUNDING CONDUCTOR FOR PV MODULES SMALLER THAN 6AWG SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY A RACEWAY OR CABLE ARMOR. [CEC 250.120(C)] 24. EQUIPMENT GROUNDING CONDUCTOR FOR PV SYSTEM CIRCUITS SHALL BE SIZED IN ACCORDANCE WITH 250.122. [CEC 690.45] 25. GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE INSTALLED IN ONE CONTINUOUS LENGTH WITHOUT A SPLICE OR JOINT. IF NECESSARY, SPLICES OR CONNECTIONS SHALL BE MADE AS PERMITTED. [CEC 250.64(C)] 26. ALL SMOKE ALARMS, CARBON MONOXIDE ALARMS AND AUDIBLE NOTIFICATION DEVICES SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 217 AND UL 2034. THEY WILL BE INSTALLED IN ACCORDANCE WITH NFPA 72 AND NFPA 720. [CRC 2019 R314 & R315] 27. SMOKE ALARMS AND CARBON MONOXIDE ALARMS WILL BE RETROFITTED INTO THE EXISTING DWELLING. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. THESE ALARMS MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME, OTHERWISE, THE ALARMS MUST BE HARD WIRED AND INTERCONNECTED. GENERAL NOTES *ALL WORK TO COMPLY WITH ABOVE CODES * OCCUPANCY TYPE: R-3 * CONSTRUCTION TYPE: TYPE V-B * UNSPRINKLERED DWELLING INFO E1 - COVER SHEET E2 - SITE PLAN E7 - SINGLE LINE DIAGRAM E8 - ELECTRICAL NOTES E9's - SIGNAGE E5 - ROOF PLAN E6 - ATTACHMENT DETAIL (N) AC COMBINER(S) - - - - 27 - - - (N) INVERTER(S) (N) SOLAR MODULE(S) - ENPHASE IQ8M-72-2-US - HANWHA Q.PEAK DUO BLK ML-G10+ 400 27 1 125A ENPHASE IQ COMBINER 4/4C 1 125A/100A NCF (N) MAIN SERVICE PANEL MSP IS UPGRADED WITH 125A/100A NCF. REVISION TO Bldg# 101114132 Issued 03/10/23 Bldg# 101116640 Issued 09/13/23 The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. 3114 S Rita Way - 2017890209/14/23 MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKING SHALL BE PLACED EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL PV COMBINER AND JUNCTION BOXES. [CEC 690.31(D)(2)] REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) MARKING CONTENT AND FORMAT PER [ CEC 110.21(B)] WITH REFERENCE TO ANSI Z535.4-2011 -BACKGROUND PER ANSI Z535.4-2011 -LETTERING PER ANSI Z535.4-2011 -MINIMUM 3/8” LETTER HEIGHT -ALL CAPITAL LETTERS -ARIAL OR SIMILAR FONT, NON BOLD MARKING PV CIRCUIT E9 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 11-09-2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 10 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 1 13 144 8 3 2 13 12 11 9 5 PV COMBINER (IF USED) FOR ILLUSTRATION ONLY (NOT ACTUAL MSP) MAIN SERVICE PANEL AC DISCONNECT (IF USED) PV METER (IF USED) LABEL LEGEND 9 1 1 2 3 4 4 5 8 9 13 13 14 5 3 5 15 15 CEC 690.56(C) CEC 705.12(C) & CEC 690.59 CEC 690.13(B) CEC 690.13(B) CEC 690.54 CEC 705.12(B)(3)(2) CEC 110.27(C)CEC 706.15(C)(4) CEC 690.13(B) CEC 705.12(B)(3)(3) CEC 705.12(D) CEC 690.56(C)(2) 3114 S Rita Way - 2017890209/14/23 LA LA MSPGASACC ACD CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: PLACARD RIVETED TO THE MAIN SERVICE PANEL E9.1 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 11-09-2023 79664 10.800 GAB R I E L L A C A R D O Z A - F A V A R A T O SA N TA A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N -4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 NOMINAL OPERATING AC VOLTAGE: BBBBBBBB NOMINAL OPERATING AC FREQUENCY:BBBBBBBB MAXIMUM AC POWER: BBBBBBBB MAXIMUM AC CURRENT: BBBBBBBB MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION: BBBBBBBB 240V 60.0Hz 8775W 36.45A 50A SOLAR LOAD CENTER NO ADDITIONAL LOADS ALLOWED PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: BBBBB A NOMINAL OPERATING AC VOLTAGE: BBBBB V 60 240 N PHOTOVOLTAIC POWER SOURCE OPERATING AC VOLTAGE: BBBBB V MAXIMUM OPERATING AC OUTPUT CURRENT: BBBBBB AMPS LABEL FOR MAIN SERVICE PANEL COVER 240 46 (YOU ARE HERE) SERVICE POINT & UTILITY METERING & PV DISCONNECT PV DISCONNECT AC DISCONNECT SOLAR ARRAY 3114 S Rita Way - 2017890209/14/23 EXI S T I N G DRI V E W A Y FIR E SETBA C K 18" FIR E SET B A C K 18"FIRE S E T B ACK 3' FIR E S E T BAC K 3' FIR E SETBA C K 18" FIR E SE T B A C K 18" ACC E S S PAT H 3" LA LA MSP GAS ACC ACD FIRE SETB A C K 18" E2 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 11-09-2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 SCALE: SITE PLAN N 1/8" = 1'-0" MSP LEGEND ACC (N) 125A ENPHASE IQ COMBINER 4/4C WITH ENVOY IQ, CELL MODEM, & WIRELESS COMMUNICATIONS KIT 27 (N) 400W HANWHA Q.PEAK DUO BLK ML-G10+ 400 SOLAR MODULES (FLUSH MOUNT) EACH WITH A (N) ENPHASE IQ8M-72-2-US MICRO-INVERTERS (N) 125A BUS NCF (N) 100A/2P MAIN BREAKER (N) 50A/2P PV BREAKER FEEDING (N) 60A AC DISCONNECT SERVICE POINT & UTILITY METERING LA LADDER ACCESS GAS (E) GAS RISER (ALL NEW EQUIPMENT TO BE PLACED 3FT. AWAY FROM GAS MAIN) ACD (N) 60A SINGLE VISIBLY OPEN AND LOCKABLE AC DISCONNECT 240V NEMA-3R POC FOR (N) 125A ENPHASE IQ COMBINER 4/4C (BELOW IQ COMBINER) MSP IS UPGRADED WITH 125A/100A NCF. 3114 S Rita Way - 2017890209/14/23 FIR E SET B ACK 18" FIR E SET B A C K 18" FIRE S E T B A C K 3' FIRE S E TBA C K 3' FIR E S ETBA C K 18" FIR E SETBA C K 18" ACCE SS PATH 3" LA LA MSP GAS ACC ACD FIRE S ETB A C K 18" TILT AZIMUT H 230° 23° TILT AZIM U T H 139° 23° TILT AZIMUT H 48° 23° TILT AZIMUT H 48° 23° TILT AZIM U T H 229 ° 23° RP3 RP2 RP4 RP 1 E5 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 11-09-2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 SCALE: ROOF PLAN N 1/8" = 1'-0" NEW PV CONDUIT TO BE RUN UNDER EVE WHENEVER POSSIBLE. ANY PROPOSED CONDUIT RUN SUBJECT TO CHANGE BY INSTALLER. 78 ATTACHMENTS INSTALLED @ 72" O.C. MAX (TYP.) 2" X 6" RAFTER @ 24" O.C. TYP. FLAT TILE ROOFING FRO N T O F R E S I D E N C E 3114 S Rita Way - 2017890209/14/23 EACH WITH AN ENPHASE IQ8M-72-2-US MICROINVERTER AC (N) J-BOX G 1 BRANCH OF MODULES9 SOURCE CIRCUIT #1 Isc = 12.15 A AC G 1 BRANCH OF MODULES9 SOURCE CIRCUIT #2 Isc = 12.15 A ENPHASE Q CABLE 2-#12 1-#6 GRND OPEN AIR THWN-2 2-#10 1-#8 GRND 3/4" EMT CONDUIT Enphase IQ Gateway REVENUE-GRADE PRODUCTION METERING FACTORY INSTALLED enphase ENERGY AC G 1 BRANCH OF MODULES9 SOURCE CIRCUIT #3 Isc = 12.15 A (N) J-BOX (N) J-BOX EACH WITH AN ENPHASE IQ8M-72-2-US MICROINVERTER EACH WITH AN ENPHASE IQ8M-72-2-US MICROINVERTER (N) 20A/2P (N) 15A/2P (N) 125A ENPHASE IQ COMBINER 4/4C NEMA-3R X-IQ-AM-1-240-4/4C [CRD-PCS NEM), 240V (N) 20A/2P (N) 20A/2P (N) 60A SINGLE VISIBLY OPEN & LOCKABLE, AC DISCONNECT 240V NEMA-3R G THWN-2 3-#6 1-#8 GRND 3/4" EMT CONDUIT MAIN SERVICE PANEL GROUNDING ELECTRODE & AUXILIARY GROUNDING ELECTRODE AS NEEDED PER CEC 690.47 (6 FEET APART) L LL L GN D N LOADS (E) A TOP FED ME T E R # 100A/2P 50A/2P 22 2 0 1 2 - 7 8 1 8 9 7 (N)125 (N) (N) E7 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 UTILITY COMPANY: MSP VOLTAGE: MSP GROUND:SERV. TYPE: SERVICE INFO SCE 120/240 UNDERGROUND (N) ROD 2% Avg. 1" MIN ASHRAE AMBIENT TEMPERATURE SPECS ° C ° C High Temp EXTREMEDISTANCE ABOVE ROOF NO TEMP ADDER PER 310.15(B)(2) 31 2 INTERCONNECTION METHOD PER 705.12(B)(3)(2): WHERE TWO SOURCES, ONE A PRIMARY POWER SOURCE AND THE OTHER ANOTHER POWER SOURCE, ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS LOADS, THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR. BUS BAR MAIN BREAKER MAX GENERATION POTENTIAL CEC 705.12(B)(3)(2) ( 125A x 1.2 ) - 100A = 50A MSP IS UPGRADED WITH 125A/100A NCF. 3114 S Rita Way - 2017890203/10/23 ELECTRICAL NOTES: 1) ALL MODULES WILL BE GROUNDED IN ACCORDANCE WITH CODE AND THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. 2) ALL PV EQUIPMENT SHALL BE LISTED BY A RECOGNIZED TESTED LAB. 3) NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM. 4) WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, BREAKER SHALL NOT READ LINE AND LOAD. 5) WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE BREAKER SHALL BE INSTALLED AT THE OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER. 6) WORKING SPACE FOR EQUIPMENT OPERATING AT 1000 VOLTS, NOMINAL, OR LESS TO GROUND AND LIKELY TO REQUIRE EXAMINATION, ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED SHALL COMPLY WITH [CEC 110.26(A)] 7) ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS PER [CEC 314.15]. 8) ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY CONTINUOUS. 9) PV EQUIPMENT, SYSTEMS AND ALL ASSOCIATED WIRING AND INTERCONNECTIONS SHALL ONLY BE INSTALLED BY QUALIFIED PERSONS. [CEC 690.4 (C)]. 10) THE PHOTOVOLTAIC SYSTEM CONDUCTORS SHALL BE IDENTIFIED AND GROUPED. THE MEANS OF IDENTIFICATION SHALL BE PERMITTED BY SEPARATED COLOR CODING, MARKING TAPE, TAGGING OR OTHER APPROVED MEANS. [CEC 690.31(B)(1)] 11) ADEQUATE SPACING MUST BE MAINTAINED BETWEEN ANY PLUMBING SEWER VENTS EXTENDING THROUGH THE ROOF AND THE UNDERSIDE OF THE PHOTOVOLTAIC PANELS (6" MINIMUM RECOMMENDED). E8 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 3114 S Rita Way - 2017890203/10/23 MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC PV CONDUIT, RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES, AND JUNCTION BOXES TO ALERT THE FIRE SERVICE TO AVOID CUTTING THEM. MARKING SHALL BE PLACED EVERY 10 FEET, AT TURNS AND ABOVE AND/OR BELOW PENETRATIONS, AND AT ALL PV COMBINER AND JUNCTION BOXES. [CEC 690.31(D)(2)] REFLECTIVE WEATHER RESISTANT MATERIAL SUITABLE FOR THE ENVIRONMENT (DURABLE ADHESIVE MATERIALS MUST MEET THIS REQUIREMENT) MARKING CONTENT AND FORMAT PER [ CEC 110.21(B)] WITH REFERENCE TO ANSI Z535.4-2011 -BACKGROUND PER ANSI Z535.4-2011 -LETTERING PER ANSI Z535.4-2011 -MINIMUM 3/8” LETTER HEIGHT -ALL CAPITAL LETTERS -ARIAL OR SIMILAR FONT, NON BOLD MARKING PV CIRCUIT E9 SHEET NUMBER: SE M P E R S O L A R I S 18 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 10 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 1 13 144 8 3 2 13 12 11 9 5 PV COMBINER (IF USED) FOR ILLUSTRATION ONLY (NOT ACTUAL MSP) MAIN SERVICE PANEL AC DISCONNECT (IF USED) PV METER (IF USED) LABEL LEGEND 9 1 1 2 3 4 4 5 8 9 13 13 14 5 3 5 15 15 CEC 690.56(C) CEC 705.12(C) & CEC 690.59 CEC 690.13(B) CEC 690.13(B) CEC 690.54 CEC 705.12(B)(3)(2) CEC 110.27(C)CEC 706.15(C)(4) CEC 690.13(B) CEC 705.12(B)(3)(3) CEC 705.12(D) CEC 690.56(C)(2) 3114 S Rita Way - 2017890203/10/23 LA LA MSPGAS ACC ACD CAUTION POWER TO THIS SERVICE IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: PLACARD RIVETED TO THE MAIN SERVICE PANEL E9.1 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 NOMINAL OPERATING AC VOLTAGE: ________ NOMINAL OPERATING AC FREQUENCY:________ MAXIMUM AC POWER: ________ MAXIMUM AC CURRENT: ________ MAX OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION: ________ 240V 60.0Hz 8775W 36.45A 50A SOLAR LOAD CENTER NO ADDITIONAL LOADS ALLOWED PHOTOVOLTAIC AC DISCONNECT RATED AC OUTPUT CURRENT: _____ A NOMINAL OPERATING AC VOLTAGE:_____ V 46 240 N PHOTOVOLTAIC POWER SOURCE OPERATING AC VOLTAGE: _____ V MAXIMUM OPERATING AC OUTPUT CURRENT: ______ AMPS LABEL FOR MAIN SERVICE PANEL COVER 240 46 (YOU ARE HERE) SERVICE POINT & UTILITY METERING & PV DISCONNECT PV DISCONNECT AC DISCONNECT SOLAR ARRAY 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 01231456178918 2388  !" #$ %& '# #( #!) ! *+# ) , -./ 0 11 23) 2 4!015) ) 3!1(  %& 6327! + 869 03!$31)# $ ! +03!! 03! :5"2 ! !3 # $!*1 !013$5+ #!) $+ #21! $ %& 20+3!; + +$ #!) $3+#* !$#11#3!$ 7( "+3;)!* # 03!$$ !< "+ -+ ) $3153! =3+ + $) !#1 #""10#3!$> % 3== +$ 5" 3 =35+ ?-"31 !"5 0+05$ #!) #3! @A $ + $ 75$7#+ #$$ 271(>  2388 01231456 1789 18 01231456 1789 18 BCDEFGHIDJCHFDGKCLMDNIOPGQFDCRRFHSITQUDVSQSMDWXYZ[\W]^_` a## b  cdefg hJGHM iDDjIkELlFQDjmDnGMFoGpDRCHDkCJJLISkGMSCIDGIlDkCIMHCE iDDjIkELlFQDNIOPGQFDqCKSEFDrCIIFkMDkFEELEGHDJClFJD srNttquvNqwqx wyz wh{wy|}UDSIkELlFlDCIEpDoSMPDjmD rCJKSIFHD~r iDDjIkELlFQDQCEGHDQPSFElDMCDJGMkPDNIOPGQFDjmDGMMFHpD €‚ƒ„ƒ…†‚‡€ˆ‰‡‰Š†ƒ‡„€ƒ iDD‹EFŒSKEFDIFMoCHSITDQLOOCHMQDŽSw‹SUDD NMPFHIFMUDCHDkFEELEGH iDDuOMSCIGEDrDHFkFOMGkEFDGVGSEGKEFDRCHD{trDKHSl TF iDD{HCVSl FQDOHClLkMSCIDJFMFHSITDGIlDkCIQLJOMSCID JCISMCHSIT hSJOEF iDrFIMFHFlDJCLIMSITDKHGkFMQDQLOOCHMDQSITEFDD QMLlDJCLIMSIT iDhLOOCHMQDKCMMCJUDKGkDGIlDQSlFDkCIlLSMDFIMHp iDODMCDRCLHD‘wOCEFDKHGIkPDkSHkLSMQDRCHD‘~yD’rDD OELT wSIDKHFGFHQDsICMDSIkELlFl } iD“yDMCMGED{’DCHDQMCHGTFDKHGIkPDkSHkLSMQ ”FESGKEF •‡–—˜€™š‡›œžŸ†˜ƒ… ‰‡›¡¢£‡ƒ¤¥‡¦œ‡ˆ†š§‚—˜ iD‹SVFwpFGHDESJSMFlDoGHHGIMp iDBoCDpFGHQDEGKCHDHFSJKLHQFJFIMDOHCTHGJDkCVFHGTFD SIkELlFlDRCHDKCMPDMPFDjmDrCJKSIFHDh¨©Q iDtDESQMFl 01231456178918 BCDEFGHIDJCHFDGKCLMDNIOPGQFDCRRFHSITQUDVSQSMDWXYZ[\W]^_` ª ?«?/ !" #$ ! +*(> ¬11 +* $ + $ +; )> !" #$ <  !" #$ 13*3< %& 6327! + 8­86< #!) 3 + !#2 $ #+ +#) 2#+®$ 3= !" #$ ! +*(< %!0> a## $57¯ 0 3 0 #!* > /«-?/-?«?/ °±²³´µ¶·°¸³¹ jmDrCJKSIFHD~DDsºwjmwqx w‘~yw~}jmDrCJKSIFHD~DoSMPDNIOPGQFDjmDnGMFoGpDOHSIMFlDkSHkLSMDKCGHlDRCHDSIMFTHGMFlDHFVFILFDTHGlFD{’DOHClLkMSCIDJFMFHSITDs»hjD rx ‘¼‘yD½¾wDy¼|¿}DGIlDkCIQLJOMSCIDJCISMCHSITDs½¾wD‘¼|¿}¼DjIkELlFQDGDQSEVFHDQCEGHDQPSFElDMCDJGMkPDMPFDjmDGMMFHpDQpQMFJDGIlD ÀÁ‡Â¤‚ƒÃ‡Ä§ˆƒ˜§šš˜‡Å‡€ˆ‰‡ƒ§‡‰Š†ƒ‡„€ƒÆ jmDrCJKSIFHD~rDsºwjm wqx w‘~yw~r}jmDrCJKSIFHD~rDoSMPDNIOPGQFDjmDnGMFoGpDOHSIMFlDkSHkLSMDKCGHlDRCHDSIMFTHGMFlDHFVFILFDTHGlFD{’DOHClLkMSCIDJFMFHSITD s»hjDrx‘¼‘yD½¾wDy¼|¿}DGIlDkCIQLJOMSCIDJCISMCHSITDs½¾wD‘¼|¿}¼DjIkELlFQDNIOPGQFDqCKSEFDrCIIFkMDkFEELEGHDJClFJD srNttquvNqwqx wyzwh{wy|}UDGDOELTwGIlwOEGpDSIlLQMHSGEwTHGlFDkFEEDJClFJDRCHDQpQMFJQDLODMCDzyDJSkHCSIVFHMFHQ¼D sVGSEGKEFDSIDMPFDhUDrGIGlGUDqFŒSkCUD{LFHMCD”SkCUDGIlDMPFDhD’SHTSIDjQEGIlQUDoPFHFDMPFHFDSQDGlFÇLGMFDkFEELEGHDQFHVSkFDSID ƒ„‡…ˆ‚ƒ€šš€ƒ…§ˆ‡€˜€ÆÈ‡Àˆ†š—‰‚‡€‡‚…šÉ˜‡‚§š€˜‡‚„…š‰‡ƒ§‡Ã€ƒ†„‡ƒ„‡ÀÁ‡Ê€ƒƒ˜¤‡€ˆ‰‡ÀÁ‡Â¤‚ƒÃ‡Ä§ˆƒ˜§šš˜‡‡€ˆ‰‡ƒ§‡‰Š†ƒ‡„€ƒÆ ËÌ Ì ³Í Í ±¹Î ³ÍµË ¶²µ¹³Ï ´ËÌ ³°³¶ÐµÏ˹ÐÍ sICMDSIkELlFlUDCHlFHDQFOGHGMFEp} NIQFJKEFDrCJJLISkGMSCIQD¨SMDD ruqqhwrNttquvNqwqx wyzD rNttquvNqwqx wyzwh{wy|D rNttquvNqwqx wyzwBwy|D wDjIkELlFQDruqqhw¨jBwyx DGIlDrNttquvNqwqx wyzwh{wy|DoSMPD|wpFGHDhOHSIMDlGMGDOEGIDRCHD DDDNIQFJKEFDQSMFQ wD~nDKGQFlDtBNwqx DkFEELEGHDJClFJDoSMPD|wpFGHDhOHSIMDlGMGDOEGI wD~nDKGQFlDtBNwqx DkFEELEGHDJClFJDoSMPD|wpFGHDBÑBDlGMGDOEGI rSHkLSMDHFGFHQ DD”¨wx yw‘w‘~y’ DD”¨wx |w‘w‘~y’ DD”¨w‘yw‘{w‘~y’ DD”¨wx |w‘{w‘~y’w DD”¨w‘yw‘{w‘~y’w —¥¥§˜ƒ‚‡¡€ƒ§ˆ‡ÊœÅÒ ÓԇʜÅÒ ÕԇʜÅÅÓԇʜŦÓԇʜÅÖÓԇʜÅÕÓԇ€ˆ‰‡ÊœÅ×Ӈ†…˜†—…ƒ‡™˜€Ø˜‚Æ DDrSHkLSMDKHFGFHUD‘DOCEFUDxyUDNGMCID”‘x yD DDrSHkLSMDKHFGFHUD‘DOCEFUDx|UDNGMCID”‘x | DDrSHkLSMDKHFGFHUD‘DOCEFUD‘yUDNGMCID”‘‘yD DDrSHkLSMDKHFGFHUD‘DOCEFUDx|UDNGMCID”‘x |DoSMPDPCElDlCoIDSMDQLOOCHM DDrSHkLSMDKHFGFHUD‘DOCEFUD‘yUDNGMCID”‘‘yDoSMPDPCElDlCoIDSMDQLOOCHM N{trwyx {CoFHDESIFDkGHHSFHDskCJJLISkGMSCIDKHSl TFDOGSH}UDÇLGIMSMpDwDCIFDOGSH ºwhut”hÙjNtvwNh ”FOEGkFJFIMDQCEGHDQPSFElDRCHDjmDrCJKSIFHD~¾~r Ú£ŸÛžÜÝ ŸÒ Åӟ¦kkFQQCHpDHFkFOMGkEFDRCHD{CoFHDtSIFDrGHHSFHDSIDjmDrCJKSIFHD~¾~rDsHFÇLSHFlDRCHDN{trwyx } Ú£Ÿ¡›ÞŸÛÄÊ£Ÿ¦”FOEGkFJFIMDjmDnGMFoGpDOHSIMFlDkSHkLSMDKCGHlDs{r}DRCHDrCJKSIFHD~¾~r ºwjmw»wÙv wx ‘|ÙCElDlCoIDSMDRCHDNGMCIDkSHkLSMDKHFGFHDoSMPDQkHFoQ¼ ³´³Ì йΠÌË´µÍ Ï³Ì Î ßÎ Ì ËÐÎ ±¶Í ”GMSIT rCIMSILCLQDlLMp hpQMFJDVCEMGTF x‘y¾‘~yD’rUDzyDÙà NGMCID”DQFHSFQDKLQKGHDHGMSIT x‘|D qGŒ¼DkCIMSILCLQDkLHHFIMDHGMSIT z|D qGŒ¼DkCIMSILCLQDkLHHFIMDHGMSITDsSIOLMDRHCJD{’¾QMCHGTF}z~D qGŒ¼DRLQF¾kSHkLSMDHGMSITDsCLMOLM}áyD HGIkPDkSHkLSMQDsQCEGHDGIl¾CHDQMCHGTF}ODMCDRCLHD‘wOCEFDNGMCID”DQFHSFQDvSQMHSKLMFlDnFIFHGMSCIDsvn}DKHFGFHQDCIEpDsICMDSIkELlFl } qGŒ¼DMCMGEDKHGIkPDkSHkLSMDKHFGFHDHGMSITDsSIOLM}“yDCRDlSQMHSKLMFlDTFIFHGMSCID¾Dá|DoSMPDjmDnGMFoGpDKHFGFHDSIkELlFl {HClLkMSCIDJFMFHSITDrB ‘yyDDQCESlDkCHFDOHFwSIQMGEEFlDGIlDoSHFlDMCDjmDnGMFoGp rCIQLJOMSCIDJCISMCHSITDrBDsrBw‘yywh{tjB}DOGSHDCRD‘yyDDQOESMDkCHFDkLHHFIMDMHGIQRCHJFHQD °³Ì â ˶ΠÌË ´µ²ËÐË vSJFIQSCIQDsŽŒÙŒv}¦ãÆÕ‡ä‡ÖåÆÕ‡ä‡Ò ×Ææ‡†Ã‡çÒ ÖÆãÕè‡ä‡Ò åÆÕè‡ä‡×Æ×¦èÈÆ‡é…ꄃ‡…‚‡ÅÒ ÆÓ×ë‡çÕ¦ÆÕ‡†Ãȇ셃„‡Ã§—ˆƒ…ˆê‡™˜€†Øƒ‚Æ ŽFSTPM ãÆÕ‡Øê‡çÒ ×ÆÕ‡š™‚È JKSFIMDMFJOFHGMLHFDHGIT F w~yíDrDMCD½~zíDrDsw~yíDMCDxx|íD‹} rCCESIT »GMLHGEDkCIVFkMSCIUDOELQDPFGMDQPSFEl NIkECQLHFDFIVSHCIJFIMGEDHGMSIT ‰§§˜Ô‡›œžŸ†˜ƒ… ‰Ô‡›¡¢£‡ƒ¤¥‡¦œÔ‡¥§š¤†€˜™§ˆ€ƒ‡†§ˆ‚ƒ˜—†ƒ…§ˆ ŽSHFDQSàFQ iDD‘yDDMCD|yDDKHFGFHDSIOLMQïDx~DMCD~DŽnDkCOOFHDkCIlLkMCHQ iDDzyDDKHFGFHDKHGIkPDSIOLMïD~DMCDx¾yDŽnDkCOOFHDkCIlLkMCHQ iDDqGSIDELTDkCJKSIFlDCLMOLMïDxyDMCD‘¾yDŽnDkCOOFHDkCIlLkMCHQ iDD»FLMHGEDGIlDTHCLIlïDx~DMCDx¾yDkCOOFHDkCIlLkMCHQ EoGpQDRCEECoDECkGEDkClFDHFÇLSHFJFIMQDRCHDkCIlLkMCHDQSàSIT¼ EMSMLlF BCD‘yyyDJFMFHQDszU|zyDRFFM} Î ¶Ð³¹¶³ÐµÌ ±¶¶³Ì Ð Î ±¶µ±ÏÐ Î ±¶Í jIMFTHGMFlDŽSw‹S “y‘¼xx K¾T¾I rFEELEGH rNttquvNqwqx wyzwh{wy|UDrNttquvNqwqx wyzwBwy|Ds~nDKGQFlDtBNwqx DkFEELEGHDJClFJ}¼DD»CMFDMPGMDGIDNIOPGQFD qCKSEFDrCIIFkMDkFEELEGHDJClFJDSQDHFÇLSHFlDRCHDGEEDNIQFJKEFDSIQMGEEGMSCIQ¼ NMPFHIFM …§ˆ€šÔ‡æÓÅÆ¦Ô‡Ä€ƒÕ¡‡ç§˜‡Ä€ƒ‡×ȇܝۇ¡ƒ„˜ˆƒ‡†€™š‡‡çˆ§ƒ‡…ˆ†š—‰‰È Ì ±°Ï ´Î Ë ¶Ì ³ rCJOESGIkFUDjmDrCJKSIFH ܞ‡Ò ãÖÒ Ô‡Ä£›ðÄ£‡ÄÅůқ§Æ‡Ò ÓãÆÒ ԇ‡Öã‡ÄñœÔ‡Û€˜ƒ‡Ò Õԇ̀‚‚‡ÊԇÀġ‡ÓÓ¦ {HClLkMSCIDJFMFHSITïD»hjDrx ‘¼‘yDGkkLHGkpDkEGQQDy¼|Ds{’DOHCl LkMSCI} rCIQLJOMSCIDJFMFHSITïDGkkLHGkpDkEGQQD‘¼| rCJOESGIkFUDjmDnGMFoGp tDzyzyx wx ¾r»rhD‘‘¼‘D»C¼Dzx yx y wx D 2388 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 EXI S T I N G DRI V E W A Y ACCESS PATH18" ACCESS PATH 18" ACC E S S PAT H 3" LA LA MSP GAS ACC ACD E2 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 SCALE: SITE PLAN N 1/8" = 1'-0" MSP LEGEND ACC (N) 125A ENPHASE IQ COMBINER 4/4C WITH ENVOY IQ, CELL MODEM, & WIRELESS COMMUNICATIONS KIT 27 (N) 400W HANWHA Q.PEAK DUO BLK ML-G10+ 400 SOLAR MODULES (FLUSH MOUNT) EACH WITH A (N) ENPHASE IQ8M-72-2-US MICRO-INVERTERS (N) 125A BUS NCF (N) 100A/2P MAIN BREAKER (N) 50A/2P PV BREAKER FEEDING (N) 60A AC DISCONNECT SERVICE POINT & UTILITY METERING LA LADDER ACCESS GAS (E) GAS RISER (ALL NEW EQUIPMENT TO BE PLACED 3FT. AWAY FROM GAS MAIN) ACD (N) 60A SINGLE VISIBLY OPEN AND LOCKABLE AC DISCONNECT 240V NEMA-3R POC FOR (N) 125A ENPHASE IQ COMBINER 4/4C (BELOW IQ COMBINER) MSP IS UPGRADED WITH 125A/100A NCF. 3114 S Rita Way - 2017890203/10/23 ACCESS PATH18" ACCESS PATH 18" FIRE SET B A C K 18" FIR E SET B A C K 18" FIRE SETBA C K 3' FIR E S E TBA C K 3' FIRE S E T B A C K 18" FIR E SE T B A C K 18" ACC E S S P A T H 3" LA LA MSP GAS ACC ACD FIRE SET B A C K 18" TILT AZIM U T H 230° 23° TILT AZIM U T H 139° 23° TILT AZIM U T H 48° 23° TILT AZIM U T H 48° 23° TILT AZIM U T H 229 ° 23°RP3 RP2 RP4 RP5 RP1 E5 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 SCALE: ROOF PLAN N 1/8" = 1'-0" NEW PV CONDUIT TO BE RUN UNDER EVE WHENEVER POSSIBLE. ANY PROPOSED CONDUIT RUN SUBJECT TO CHANGE BY INSTALLER. 86 ATTACHMENTS INSTALLED @ 72" O.C. MAX (TYP.) 2"x6" RAFTER @ 24" O.C. TYP. FLAT TILE ROOFING FRO N T O F R E S I D E N C E 3114 S Rita Way - 2017890203/10/23 (N) MODULE (E) CONCRETE FLAT TILE (E) ROOF DECKING (E) RAFTER, SEE E5 FOR DETAIL (N) 5/16" x 4.5" PEGASUS LAG BOLT MIN 2.5" EMBEDMENT (N) PEGASUS MULTI CLAMP (N) PEGASUS RAIL (N) PEGASUS DOVETAIL T-BOLT (N) PEGASUS L-FOOT (N) PEGASUS FLAT TILE POST (N) PEGASUS FLAT TILE TILE REPLACEMENT FLASHING (N) PEGASUS FLAT TILE POST SLED (N) PEGASUS FLAT TILE BASE FLASHING E6 SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 ATTACHMENT DETAIL 3114 S Rita Way - 2017890203/10/23 LA LA MSP GAS ACC ACD JHA SHEET NUMBER: SE M P E R S O L A R I S 1 8 0 5 J O H N T O W E R S A V E EL C A J O N , C A 9 2 0 2 0 C- 1 0 L I C # 9 7 8 1 5 2 Li c . H o l d e r D i g i t a l l y S t a m p e d PR O J E C T F O R : PR O P O S E D DRAWN BY: DATE: (DC) kW: PROJECT #: Jo h n A l m o n d FIN-S 2/7/2023 79664 10.800 GA B R I E L L A C A R D O Z A - F A V A R A T O SA N T A A N A C A 9 2 7 0 4 31 1 4 S R I T A W A Y (2 1 0 ) 5 4 2 - 2 5 0 2 AP N - 4 1 2 0 1 3 1 9 SO L A R P H O T O V O L T A I C SY S T E M S I Z E : 1 0 . 8 0 0 k W D C P V MA I N L I N E : 6 1 9 - 3 5 7 - 4 1 4 2 NEAREST URGENT CARE VICINITY MAP DISTANCE ADDRESS NAME CONDITIONS NCREW MEMBER CREW LEAD CREW MEMBER CREW MEMBER ROPE REACH LADDER ACCESS CONES EXCLUSION ZONE JHA LEGEND ANCHOR POINTS N THIS PAGE TO BE COMPLETED BY INSTALLATION CREW 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 3114 S Rita Way - 2017890203/10/23 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1.   Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2.   Will the PV system be installed on a roof having only one roofing layer with no overlays? 3.   Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4.   Will the PV system weigh maximum 4 pounds per square feet or less? 5.   Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6.   Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7.   Will the PV system be installed without using any ballast system or counter-weight system? 8.   Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9.   Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10.   Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org Ketan 3114 S Rita Way - 2017890203/10/23