Loading...
HomeMy WebLinkAbout3810 S Teakwood St - PlanCertificate Of Completion Envelope Id: E147757B67B540A8AFC3B3178A8B391D Status: Completed Subject: Complete with DocuSign: Authorization letter.pdf Source Envelope: Document Pages: 1 Signatures: 1 Envelope Originator: Certificate Pages: 2 Initials: 0 Harina Kapoor AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-06:00) Central Time (US & Canada) 2017 Greenleaf St Santa Ana, CA 92706 harina@aikyum.com IP Address: 98.149.3.88 Record Tracking Status: Original 9/14/2023 11:27:01 AM Holder: Harina Kapoor harina@aikyum.com Location: DocuSign Signer Events Signature Timestamp Kim Tong kayttong@gmail.com Security Level: Email, Account Authentication (None) Signature Adoption: Drawn on Device Using IP Address: 187.199.194.21 Signed using mobile Sent: 9/14/2023 11:28:15 AM Viewed: 9/15/2023 12:23:44 PM Signed: 9/15/2023 12:24:10 PM Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Harina Kapoor harina@aikyum.com CEO Aikyum Inc. Security Level: Email, Account Authentication (None) Sent: 9/14/2023 11:28:15 AM Resent: 9/15/2023 12:24:11 PM Electronic Record and Signature Disclosure: Not Offered via DocuSign Viktor Tieu viktor@aikyum.com Security Level: Email, Account Authentication (None) Sent: 9/14/2023 11:28:15 AM Electronic Record and Signature Disclosure: Not Offered via DocuSign Witness Events Signature Timestamp Notary Events Signature Timestamp 3810 S Teakwood St - 2018104710/5/2023 Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted 9/14/2023 11:28:15 AM Certified Delivered Security Checked 9/15/2023 12:23:44 PM Signing Complete Security Checked 9/15/2023 12:24:10 PM Completed Security Checked 9/15/2023 12:24:10 PM Payment Events Status Timestamps 3810 S Teakwood St - 2018104710/5/2023 Expedited Permit Process for PV Systems - Micro-Inverter1 Expedited Permit Process for PV Systems Micro-Inverter The Solar America Board for Codes and Standards (Solar ABCs) Expedited Permit Pro- cess provides a means to differentiate systems that can be permitted quickly and easily due to their similarity with the majority of small-scale PV systems. Those systems with unique characteristics may be handled with small additions to this Expedited Permit Process or may require much more information, depending on the uniqueness of the installation. The following pages contain forms for the Micro-Inverter to use with the Expedited Per- mit Process. The Standard String, AC Module, and Supply-Side Connection forms are also available as interactive PDF files at www.solarabcs.org/permitting. In jurisdic- tions that have adopted the Expedited Permit Process for PV Systems, these forms can be filled out electronically and submitted in either printed form and via email. An elec- tronic format is used so that the supplied information is standardized and legible for the local jurisdiction. 3810 S Teakwood St - 2018104710/5/2023 Expedited Permit Process for PV Systems — Micro-Inverter 2 Expedited Permit Process for Small-Scale PV Systems Micro-Inverter The information in this guideline is intended to help local jurisdictions and contractors identify when PV system installations are simple, needing only a basic review, and when an installation is more complex. It is likely that 50%-75% of all residential systems will comply with these simple criteria. For projects that fail to meet the simple criteria, resolution steps have been suggested to provide as a path to permit approval. Required Information for Permit: 1. Site plan showing location of major components on the property. This drawing need not be exactly to scale, but it should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings with a 3’ perimeter space at ridge and sides may not need separate fire service review. 2. Electrical diagram showing PV array configuration, wiring system, overcurrent protection, inverter, disconnects, required signs, and ac connection to building (see supplied standard electrical diagram). 3. Specification sheets and installation manuals (if available) for all manufactured components including, but not limited to, PV modules, inverter(s), combiner box, disconnects, and mounting system. Step 1: Structural Review of PV Array Mounting System Is the array to be mounted on a defined, permitted roof structure? l Yes l No If No due to non-compliant roof or a ground mount, submit completed worksheet for the structure WKS1. Roof Information: 1. Is the roofing type lightweight (Yes = composition, lightweight masonry, metal, etc…)__________________________ ____________________________________________________________________________________________________ If No, submit completed worksheet for roof structure WKS1 (No = heavy masonry, slate, etc…). 2. Does the roof have a single roof covering? l Yes l No If No, submit completed worksheet for roof structure WKS1. 3. Provide method and type of weatherproofing roof penetrations (e.g. flashing, caulk).____________________________ Mounting System Information: 1. Is the mounting structure an engineered product designed to mount PV modules with no more than an 18” gap beneath the module frames? l Yes l No If No, provide details of structural attachment certified by a design professional. 2. For manufactured mounting systems, fill out information on the mounting system below: a. Mounting System Manufacturer ___________Product Name and Model#________________________________ b. Total Weight of PV Modules and Rails ___________lbs c. Total Number of Attachment Points____________ d. Weight per Attachment Point (b÷c)_________________lbs (if greater than 45 lbs, see WKS1) e. Maximum Spacing Between Attachment Points on a Rail ______________inches (see product manual for maximum spacing allowed based on maximum design wind speed) f. Total Surface Area of PV Modules (square feet)_________________ ft2 g. Distributed Weight of PV Module on Roof (b÷f)_______________ lbs/ft2 If distributed weight of the PV system is greater than 5 lbs/ft2, see WKS1. Step 2: Electrical Review of PV System (Calculations for Electrical Diagram) In order for a PV system to be considered for an expedited permit process, the following must apply: 1. PV modules, utility-interactive inverters, and combiner boxes are identified for use in PV systems. 2. The PV array is composed of 4 series strings or less per inverter. 3. The total inverter capacity has a continuous ac power output 13,440 Watts or less 4. The ac interconnection point is on the load side of service disconnecting means (690.64(B)). 5. One of the standard electrical diagrams (E1.1, E1.1a, E1.1b, or E1.1c) can be used to accurately represent the PV system. Interactive PDF diagrams are available at www.solarabcs.org/permitting. Fill out the standard electrical diagram completely. A guide to the electrical diagram is provided to help the applicant understand each blank to fill in. If the electrical system is more complex than the standard electrical diagram can effectively communicate, provide an alternative diagram with appropriate detail. 3810 S Teakwood St - 2018104710/5/2023 3810 S Teakwood St - 2018104710/5/2023 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 4 Micro-Inverter Electrical Diagram Contractor Name, Address and Phone:One-Line Standard Electrical Diagram for Micro-Inverter PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.1a SCALE NTS Date: SHEET Drawn By: Checked By: DESCRIPTION OR CONDUCTOR TYPE USE-2 or PV WIRE GEC EGC X ALL THAT APPLY EXTERIOR CABLE LISTED W/ INV. THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY NO DC GEC IF 690.35 SYSTEM THWN-2 or XHHW-2 or RHW-2 GEC EGC X ALL THAT APPLY TAG 1 2 3 4 5 CONDUIT AND CONDUCTOR SCHEDULE COND. GAUGE MFG MFG NUMBER OF CONDUCTORS MFG Cable MFG Cable CONDUIT TYPE N/A N/A N/A SAME SAME CONDUIT SIZE N/A N/A N/A SAME SAME DESCRIPTION PV DC or AC MODULE DC/AC INVERTER (MICRO) J-BOX (IF USED) PV ARRAY AC COMB. PANEL (IF USED) GEN METER (IF USED) AC DISCONNECT (IF USED) SERVICE PANEL TAG 1 2 3 4 5 6 7 8 PART NUMBER NOTES FOR UNUSED MODULES PUT "N/A” in BLANK ABOVE 1 1 3 2 3 EQUIPMENT SCHEDULE 2 _____ MICRO-INVERTERS IN BRANCH- CIRCUIT MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC MOD ____ DC AC J-BOX 4 AC DISCO M BUILDING GROUNDING ELECTRODE G M UTILITY SERVICE MAIN SERVICE PANEL MAIN OCPD INVERTER OCPD 6 7 8 5 4 5 G SEE GUIDE APPENDIX D FOR INFORMATION ON MODULE AND ARRAY GROUNDING AC COMBINER PANEL G ____ MICRO-INVERTERS IN BRANCH- CIRCUIT 3810 S Teakwood St - 2018104710/5/2023 E x p e d i t e d P e r m i t P r o c e s s f o r P V S y s t e m s 5 Contractor Name, Address and Phone:Notes for One-Line Standard Electrical Diagram for Single-Phase PV Systems Site Name: Site Address: System AC Size: SIZE FSCM NO DWG NO REV E1.2a SCALE NTS Date: SHEET Drawn By: Checked By: MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE (TYP 600VDC) VOC TEMP COEFF (mV/oC or %/oC ) IF COEFF SUPPLIED, CIRCLE UNITS MODULE MAKE MODULE MODEL PV MODULE RATINGS @ STC (Guide Section 5) MAX DC VOLT RATING MAX POWER @ 40oC NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL INVERTER RATINGS (Guide Section 4) 1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE REQUIREMENT? YES NO N/A 2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE REQUIREMENT? YES NO N/A 3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT 4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER OCPD AMPERE RATING. (See Guide Section 9) 5) TOTAL OF ______ INVERTER OUTPUT CIRCUIT OCPD(s), ONE FOR EACH MICRO- INVERTER CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? YES NO NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): 1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP ____oC 2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE ____oC 2.) 2009 ASHRAE FUNDAMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED 47oC IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1oC). FOR LESS THAN 9 CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF 47oC OR LESS (ALL OF UNITED STATES), a) 12 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER FUSE. b) 10 AWG, 90oC CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER FUSE. NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix E): OCPD = OVERCURRENT PROTECTION DEVICE NATIONAL ELECTRICAL CODE®REFERENCES SHOWN AS (NEC XXX.XX) NOTES FOR ALL DRAWINGS: SIGNS–SEE GUIDE SECTION 7 SIGN FOR DC DISCONNECT SIGN FOR INVERTER OCPD AND AC DISCONNECT (IF USED) No sign necessary since 690.51 marking on PV module covers needed information AC OUTPUT CURRENT NOMINAL AC VOLTAGE SOLAR PV SYSTEM AC POINT OF CONNECTION THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) Notes for Micro-Inverter Electrical Diagram 3810 S Teakwood St - 2018104710/5/2023 0 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714)902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com COVER PAGE 1. ALL ELECTRICAL MATERIALS SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY 2. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED 3. ALL METALLIC EQUIPMENT SHALL BE GROUNDED 4. ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. 5.CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS PRIOR TO INSTALLATION AND SHALL COORDINATE ALL INSPECTIONS, TESTING COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED. 6.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY AND COMPLY WITH ALL UTILITY COMPANIES REQUIREMENTS. IF THE SOLAR BACK FED BREAKER IS OVER THE BUSS SIZE 20% LIMIT, CONTRACTOR SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE MAIN CAPACITY. 7. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 8. IF THE ROOF MATERIAL OR ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION, CALL ENGINEER PRIOR TO INSTALL. THE CONTRACTOR IS RESPONSIBLE TO VERIFY THAT THE ROOF IS CAPABLE OF WITHSTANDING THE EXTRA WEIGHT. 9. IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 10. WHENEVER A DISCREPANCY IN QUALITY OF EQUIPMENT ARISES ON THE DRAWING OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEERS. OWNER SCOPE PROJECT ADDRESS PROJECT DATA GENERAL NOTES VICINITY MAP SHEET INDEX 0 COVER PAGE PHOTOVOLTAIC NOTES SATELLITE VIEW BUILDING INFORMATION: SINGLE LINE DIAGRAM CODE REQUIRED SIGNAGE 3 4 ATTACHMENT LAYOUT5 6 7 INVERTER DATA SHEET D1 MODULE DATA SHEET RACKING DATA SHEET MODULE & RACKING CERTIFICATE ATTACHMENT DATA SHEET ELECTRICAL INFORMATION MAIN SERVICE PANEL BUSBAR RATING MAIN SERVICE BREAKER RATING 1ɸ, 3W, 120/240V ROOF PLAN MODULE MAP RACKING INFORMATION Main Service Panel Solar Module Micro Inverter / Optimizer EMT / FMT / PVC / RMC type conduit/ Romex NM Cable/ FNMT (Fluid non-metalic tube) 36'' SetbackInverter Utility Meter Production Meter PV Load Center IQ Combiner Box Junction Box Sunpower PV Supervisor 18'' Setback EV Outlet CONSTRUCTION TYPE: V-B ROOF TYPE AHJ APN LOT AREA LIVING AREA MSP UM PM INV PV PVS6 IQ J/B EV KIM TONG 10 10 ENPHASE IQ8A-72-2-US 3810 TEAKWOOD ST SANTA ANA, CA 92707 SSP Service Sub Panel FLAT CONCRETE TILE 1,631 SQFT 41006412 CITY OF SANTA ANA WIRE SIZE CALCULATIONS INVERTER MAP D2 D3 D4 D5 D6 GROUNDING SPECSD7 ROOF MOUNT INSTALLATION OF DC PHOTOVOLTAIC SYSTEM 4.10 KW DC 4.10 KW 3.66 KW AC NEW UPGRADED ALL OTHER ORDINANCE ADOPTED BY THE LOCAL GOVERNING AGENCIES THE INSTALLATION OF SOLAR ARRAYS AND PHOTOVOLTAIC POWER SYSTEMS SHALL COMPLY WITH THE FOLLOWING CODES: 2022 CALIFORNIA BUILDING CODE 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA FIRE CODE 2022 CALIFORNIA PLUMBING CODE 2022 CALIFORNIA ELECTRICAL CODE 2022 CALIFORNIA MECHANICAL CODE 2022 CALIFORNIA ENERGY CODE 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE 2022 CALIFORNIA HISTORICAL CODE 2022 CALIFORNIA EXISTING BUILDING CODE 2022 CALIFORNIA REFERENCED STANDARDS CODE 2022 CALIFORNIA ADMINISTRATIVE STANDARDS CODE 1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. 2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. 4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. 5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. 6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. 8 .INVERTER IS EQUIPPED W/ INTEGRATED GFCI, THUS PROVIDING GROUND FAULT PROTECTION 9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED 10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. 11. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6) 12. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS SIZED AS PER CEC 250.122 13. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. 14. PER ART 250.92. NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. BOND BOTH ENDS OF RACEWAYS 1 2 6,564 SQFT 1.1 SITE PLAN Battery BackupBB Auto TransformerAT Solar Edge Meter EnclosureSEM Distribution PanelDP Rapid Shutdown Controller RSC Rapid Shutdown Box RSB Itron MeterIM UNIT INDEX CODE REFERENCES SNAPNRACK RACKING RAFTERS 2"X6" @ 24" O.C OCCUPANCY: R ONE STORY BUILDING 200A 225A REC SOLAR-REC410AA PURE Black 61730 (don't delete this note) IQ BATTERY DATA SHEETD8 ENPHASE IQ BATTERY 5P2 IQ COMBINER BOX DATA SHEET The scope of the plans is for the installation of the solar photovoltaic system only and the approval is subject to compliance with all applicable city and state codes and regulations regarding construction. The approval of the plans does not constitute any certification of the accuracy, completeness, or building permit status of the existing buildings and structures as shown. Bldg# 101116735 Elec# 20181047 MSmith Issued 10/05/23 3810 S Teakwood St - 2018104710/5/2023 1 ROOF PLAN PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com N 0° S 180° E 90° W 270° SCALE 0 51 10ft ROOF AREA CALCULATIONS FIRE SPRINKLERS - NO TOTAL ROOF AREA (SQ.FT.) - 2,525 SOLAR AREA (SQ.FT.) - 200 % OF COVERED AREA - 7.9% PHOTOVOLTAIC SYSTEM 10 Enphase Energy Microinverters (IQ8A-72-2-US) FROM JUNCTION BOX TO ROOF EAVE EMT TYPE CONDUIT WILL RUN OVER THE ROOF AT 1 1/2" HEIGHT, THEN UNDER THE EAVE TO PV EQUIPMENT4.10 KW DC 10 Rec Solar-REC410AA Pure Black As the home owner I certify that conduit run from the roof to the main service panel along with the placement of all solar equipment has been explained by the foreman to me and I approve it. Home Owner Signature Home Owner's Name MSP Gate Gate Te a k w o o d S t 18 ' ' f i r e s e t b a c k 18'' fire setba c k 36 ' ' f i r e s e t b a c k Solar Array 10 REC 410W Modules 10 IQ8A Microinverters Tilt: 12 Deg Azimuth: 190 Deg Slope Change Line IQ IQ Battery J/B 3810 S Teakwood St - 2018104710/5/2023 1.1 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com SITE PLAN N 0° S 180° E 90° W 270° PROPERTY LINE SCALE 0 51 10ft Gate Gate 100' 75' 95' 7'23' 46' 59' PROPERTY LINE Dr i v e w a y T e a k w o o d S t Pu b l i c S i d e w a l k MSP IQ IQ Battery 3810 S Teakwood St - 2018104710/5/2023 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com IQ COMBINER BOX DATA SHEET D3 3810 S Teakwood St - 2018104710/5/2023 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com D4 RACKING DATA SHEET 3810 S Teakwood St - 2018104710/5/2023 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com ATTACHMENT DATA SHEET D5 3810 S Teakwood St - 2018104710/5/2023 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com D6 MODULE & RACKING CERTIFICATE 3810 S Teakwood St - 2018104710/5/2023 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com D7 GROUNDING SPECS 3810 S Teakwood St - 2018104710/5/2023 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com D8 IQ BATTERY DATA SHEET 3810 S Teakwood St - 2018104710/5/2023 2 SINGLE LINE DIAGRAM PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com ITEM DESCRIPTION QTY# PV MODULE MAIN SERVICE PANEL MAIN SERVICE PANEL & UTILITY METER BUSBAR RATING BREAKER RATING 1 ITEM DESCRIPTION QTY# PVC JUNCTION BOX 4"x4"x2" UL LISTED WATER TIGHT NEMA TYPE 3 1 1 2 3 INVERTER PEAK PWR TRACKING VOLTAGE CEC EFFICIENCY PROTECTION RATING: MAXIMUM INPUT CURRENT MAXIMUM OUTPUT CURRENT MAXIMUM INPUT POWER MAXIMUM CONTINUOUS OUTPUT POWER 4 10 Enphase Energy Microinverters (IQ8A-72-2-US) 36 - 45 V 97.5 % NEMA 6 15.0 A 1.45 A 295-500 W 349 W IQ COMBINER INSTALL 40A PV 2-POLE C/B INSTALL 20A PV 2-POLE C/B 0 1 8 1 15A PV 2-POLE C/B (2)#14 AWG THWN-2 (L1+L2) (1)#14 AWG-NEUTRAL IQ GATEWAY INFORMATION ENPHASE IQ COMBINER BOX WITH ENPHASE IQ GATEWAY 120/240V, NEMA 3R MODEL# X-IQ-AM1-240-(5/5C) NEW UPGRADED NEW 1200A 225A 225A FOR WIRE SIZE CALCULATIONS PLEASE SEE PAGE #3 10 Rec Solar 410W REC410AA Pure Black Voc = 49.0V Vmp = 42.7V Isc = 10.35A Imp = 9.61A 27ENPHASE IQ BATTERY ENPHASE IQ BATTERY IQ BATTERY 5P 5 KWH 1 4 3 1 8 2 20A 3/4" EMT CONDUIT 15 FEET 3 3/4" EMT CONDUIT 34 FEET CELLULAR MODEM KIT COMMS KIT Ethernet or Wi-fi is primary comm`s for Gateway information to Enlighten INSTALL 2P 60A CB(PV+BATTERY) AT OPPOSITE END OF BUS FROM MAIN FEEDER CB 690.13(E) allows for the enclosure providing access to the disconnecting means to be lockable. In this case the enclosure is the main panel housing the breaker which serves as the disconnecting means for the solar. 690.13(A) does not allow blade style AC disconnects because there are exposed electrical parts without the need for a tool or lock to open. MAIN SERVICE PANEL 120/240V 1P,3W 2 EXISTING GROUNDING SYSTEM UTILITY M (N)200A CONSUMPTION CT Branch: (10) Modules, (10) Microinverters (2) #8 AWG THWN-2 (1) #10 AWG CU EGC, 3/4'' EMT TYPE CONDUIT (2) #8 AWG THWN-2 (1) #10 AWG CU EGC, 3/4'' EMT TYPE CONDUIT 7 7 40A 15A 3810 S Teakwood St - 2018104710/5/2023 97.5% 1.45 1.45 10 IQ8A-72-2-US (CEC) FROM JBOX TO IQ COMBINER BOX FROM IQ COMBINER BOX TO MAIN SERVICE PANEL 1 1/2'' TEMP. DERATE FACTOR (TEMP - 39 + 22 = 61C)0.58 RACEWAY HEIGHT FROM ROOF PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com 3 WIRE SIZE CALCULATIONSFROM PV MODULES TO JBOX #12 AWG Q-CABLE, PV WIRE(2)1 (1) #6 AWG BARE CU EGC 2 #10 AWG CU EGC, (3) 3 (1) #10 AWG CU EGC, MAXIMUM INVERTER OUTPUT CURRENT WALL TEMPERATURE FACTOR OUTPUT CALCULATIONS PV SYSTEM MAX DC OUTPUT PV SYSTEM MAX AC OUTPUT 1.25 0.91 (2) (1) 10 Pmax (PTC Rating) 3/4'' EMT TYPE CONDUIT 3/4'' EMT TYPE CONDUIT #10 AWG THWN-2 WIRE CHART WIRE CHART 1 NUMBER OF SERIES IN BRANCH CIRCUIT BRANCH CIRCUITS INVERTER OUTPUT MAX CURRENT COEFFICIENT 1.25 10 BRANCH CIRCUIT CURRENT: 10 BREAKER SIZE PER BRANCH CRCT 20A ADJST. FACTOR (1 thru 3 WIRES)1.0 * *1.2510 1.45 18.1A ADJUSTED CONDUCTOR AMPACITY / /18.1 0.58 1.0 31.2A NUMBER OF MICROINVERTERS 4.10KW 3.66KW MAIN SERVICE PANEL RATING BUSBAR RATING MAIN BREAKER PV & BATTERY BACKFEED BREAKER SIZE 120% RULE: MAX ALLOWED FEED 60A 200A 225A 270A 200A''MB'' + 60A "SOLAR" = 260A ≤ 270A MAX WIRE CHART QTY CONSIDER CONTINUOUS COEFFICIENT CONSIDER CONTINUOUS (A) #6 AWG THWN-2 TEMPERATURE ADJUSTMENT (A) 10 Attention!!!!!!! Need Calculation (don't delete this note) 10 10 410W * 410 391.2W * 366 REC1 AA PURE Black 1.25* *10 1.45 18.1 *1.25 / 0.91*10 1.45 19.9 3810 S Teakwood St - 2018104710/5/2023 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com 4 N 0° S 180° E 90° W 270° CAUTION MARKINGS, LABELS AND WARNING SIGNS A. Purpose: Provide emergency responders with appropriate warning and guidance with respect to isolating solar electric system. This can facilitate identifying energized electrical lines that connect solar panels to the inverter, as these should not be cut when venting for smoke removal B. Main Service Disconnect. 1. Residential buildings - The marking main be placed within the main service disconnect. The marking shall be placed outside cover if the main service disconnect is operable with the service panel closed. 2. Commercial buildings - The marking shall be placed adjacent to the main service disconnect clearly visible from the location where the level is operated 3. Markings: Verbiage, Format and Type of Material. a. Verbiage: CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED b. Format: White lettering on a red background. Minimum 3/8 inches letter height. All letters shall be capitalized. Arial or similar font, non bold. c. Material: Reflective, weather resistant material suitable for the environment (use UL - 969 as standard for weather rating). Durable adhesive materials meet this requirement. C.Marking Requirements on DC conduit, raceways, enclosures, cable assemblies, DC combiners and junction boxes: 1. Markings: Verbiage, Format and Type of Material. a. Placement : Markings shall be placed every 10 feet on all interior and exterior DC conduits, raceways, enclosures, and cable assemblies, at turns, above and for below penetrations, all DC combiners and junction boxes b. Verbiage: CAUTION: SOLAR CIRCUIT Note: The format and type of material shall adhere to "V. V-3b, c" of this requirement. c. Inverters are not required to have caution markings 1.Marking is required on all interior and exterior DC conduit raceways,enclosures,cable assemblies,and junction boxes,combiner boxes and disconnects.CFC 605.11.1 2.The materials used for marking shall be reflective,weather resistant material suitable for the environment. Minimum 3/8 "letter height; all upper case letters Arial or similar font; Red background with white lettering. CFC 605.11.1.1 3.Marking shall contain the words: WARNING : PHOTOVOLTAIC POWER SOURCE. CFC 605.11.1.2 4.Marking shall be placed adjacent to the main service disconnect in a location clearly visible from the location where the disconnect is operated CFC 605.11.1.3 POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT AiKYUM SOLAR (888) 9898 SUN (786) Permanent directory or plaque providing location of service disconnecting means and photovoltaic system disconnecting means, if not located at the same location. (Plaques shall be metal or plastic, with engraved or machine printed letters, or electro-photo plating, in a contrasting color to the plaque. Plaques shall be permanently attached to the equipment or in the required location using an approved method that is suitable to withstand the environment to which it is exposed. Plaques and signage shall meet legibility, defacement, exposure and adhesion requirements of Underwriters Laboratories marking and labeling system 969(UL969). Plaques will have red background & white lettering. 1 (TO BE LOCATED ON SUB-PANEL ONLY WHEN SUB-PANEL IS DEDICATED FOR PV ONLY) 3 6 (STICKER LOCATED INSIDE PANEL BELOW PV BREAKER) PV ARRAY J BOX PV SUB-PANEL * if applicable SUB-PANEL * if applicable METER MAIN SERVICE PANEL 1 2 3 6 6 6 *if applicable WARNING! ELECTRIC SHOCK HAZARD. IF GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED. 2 (STICKER LOCATED ON THE PV SUB PANEL) AC Disconnect * if applicable 5 5 4 4 Note: Labels shall be 3/8” in height CODE REQUIRED SIGNAGE PV SUB-PANEL ONLY PV LOAD CENTER SIZED FOR PV BREAKERS ONLY OR RENDERED UNABLE TO ACCEPT ANY ADDITIONAL LOADS. AC DISCONNECT AC PHOTOVOLTAIC POWER SOURCE RATED AC OUTPUT CURRENT: 14.5 A MAX NOMINAL AC OPERATING VOLTAGE: 240 Vac SOLAR ELECTRIC PV PANELS SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH ON THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN ARRAY WARNING POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. INVERTER/ COMBINER BOX WARNING: DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM OPERATING VOLTAGE = 240V / MAX. CURRENT = 14.5A * DO NOT RELOCATE PV OVERCURRENT DEVICE *7 SERVICE POINT & UTILITY METERING SOLAR ARRAY ON THE ROOF IQ COMBINER BOX IQ BATTERY T e a k w o o d S t 3810 S Teakwood St - 2018104710/5/2023 ATTACHMENT LAYOUT 5 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com STRUCTURAL STAMPROOF PITCH ROOFING TYPE ATTACHMENT TYPE FRAMING TYPE FRAMING SIZE PENETRATION PATTERN 12° RACKING TYPE MAX PENETRATION SPACING ROOFING LAYERS WIND SPEED 110 MPH SNOW LOAD 0 PSF EXPOSURE C LAG BOLTS MOUNTS AND MOUNTING HARDWARE WILL BE SEALED WITH CHEM LINK SEALANT OR EQUIVALENT. MODULE WEIGHT (LBS) # OF MODULES TOTAL MODULE WEIGHT (LBS) RACK WEIGHT (LBS) TOTAL SYSTEM WEIGHT (LBS) # OF STANDOFFS LOADING PER STANDOFF (LBS) TOTAL MODULE AREA (SQ.FT.) LOADING (PSF) WEIGHT LOAD CALCULATION INDEX ROOF SHEATHED WITH 1/2" PLYWOOD AND UPPER SURFACE IS FACED WITH FELT PAPER TOTAL ROOF AREA (Sq. FT) % OF COVERED AREA PV MODULE MODEL # MICROINVERTER WEIGHT (LBS) 10 Roof 1 Layer Flat Concrete Tile SnapNrack Ultra Rafter Stacked 72"2"X6" @ 24" O.C 5/16" X 3.5" SnapNrack UR Tile Hook F DESCRIPTION:DRAWN BY: SNAPNRACK, ULTRA RAIL TILE HOOK F PART NUMBER(S): 242-01247 mwatkins REVISION: A Solar Mounting Solutions 595 MARKET STREET, 29TH FLOOR ● SAN FRANCISCO, CA 94105 USA PHONE (415) 580-6900 ● FAX (415) 580-6902 THE INFORMATION IN THIS DRAWING IS CONFIDENTIAL AND PROPRIETARY. ANY REPRODUCTION, DISCLOSURE, OR USE THEREOF IS PROHIBITED WITHOUT THE WRITTEN CONSENT OF SUNRUN SOUTH LLC. .33 TYP 1.50 1.62 1.50 1.18 .38 8.84 6.20 3.39 1.25SLOT 5.12MAX 5.58 3.58 2.19 5°1.50 2.25 .20 ALL DIMENSIONS IN INCHES MIN 2.5" EMBEDMENT RACKING RAIL ATTACHMENT ROOF FRAMING 16 200 2525 452 90 24 566 35.4 2.83 7.9 2''X6'' Blocking 2''X4'' Support 2''X4'' Purlin 2''X6'' Collar Tie SOLAR MODULE ROOF ASCE 7-16 Max 3.5'' 45.2 Rec Solar- REC410AA Pure Black 72"24" 3810 S Teakwood St - 2018104710/5/2023 6 MODULE MAP PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com [FOR INSTALLER USE ONLY] PHOTOVOLTAIC SYSTEM 10 Enphase Energy Microinverters (IQ8A-72-2-US) 4.10 KW DC 10 Rec Solar 410W Modules (REC410AA Pure Black) Solar Array 10 REC 410W Modules 10 IQ8A Microinverters Tilt: 12 Deg Azimuth: 190 Deg 3810 S Teakwood St - 2018104710/5/2023 7 PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com INVERTER MAP INVERTERPHOTOVOLTAIC SYSTEM 10 ENVOY SERIAL #: ENVOY LOCATION: COMMUNICATION LEVEL: ETHERNET BRIDGE INSTALLED: NOTES: Enphase Energy Microinverters (IQ8A-72-2-US) 4.10 KW DC [FOR INSTALLER USE ONLY] 10 Rec Solar 410W Modules (REC410AA Pure Black) Solar Array 10 REC 410W Modules 10 IQ8A Microinverters Tilt: 12 Deg Azimuth: 190 Deg 3810 S Teakwood St - 2018104710/5/2023 D1 MODULE DATA SHEET PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com 3810 S Teakwood St - 2018104710/5/2023 INVERTER DATA SHEET PV SYSTEM AS INDICATED AUGUST 22, 2023 KIM TONG 3810 TEAKWOOD ST SANTA ANA, CA 92707 Aikyum Solar Address: 7256 Garden Grove Blvd, Westminster CA 92683 Phone Number: (714) 902 1462 Lic type: C-10, C-46 Lic# 986427 CONTRACTOR Designed By: Inter Solar Cad www.intersolarcad.com D2 3810 S Teakwood St - 2018104710/5/2023 3810 TEAKWOOD ST., SANTA ANA, CA 92707 TONG, KIM Prepared For: AIKYUM SOLAR 7256 GARDEN GROVE BLVD WESTMINSTER, CA 92683 714-902-1462 Design Criteria 1- Code: CALIFORNIA BLDG CODE 2022 / ASCE 7-16 2 - Wind: 110 MPH, Exposure: C 3 - Wood Species: DF-L No. 2 (SG = 0.5 ) Notice: Use restrictions of these calculations. The attached Calculations are valid only when bearing original signature hereon. Contractor/Client to verify existing dimensions/conditions prior to construction & solar racking is installed per manufacturer span requirements. The use of these calculations is solely intended for the above mentioned project. 9/8/2023 Structural Calculations for SOLAR POWER SYSTEM CONNECTION CHECK AT: Job: 1-844-PV ELITE | info@yoursolarplans.com 3000 E. Birch Street Suite 201 | Brea CA 92821 3810 S Teakwood St - 2018104710/5/2023 ASCE 29.4.4 Rooftop Solar Panels Parallel to the Roof Surface on Buildings of All Heights and Roof Slopes. Roof Slope =12 ° Roof Shape Gable Tributary Width s =6.00 ft Tributary Length l =2.99 ft Effective Area Ae =17.93 ft2 Height of Structure h =15 ft Wind Speed V =110 mph Exposure Category C Building Width B =35 ft Building Length L =50 ft Zone Width a =3.5 ft Elevation Height zg =40 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.85 Velocity Pressure qz = 0.00256KzKztKdKeV2 =22.32 psf Solar Array Pressure Equalization a =0.76 Array Edge Factor E =1.50 Zone GCp p = qz(GCp)(E)(a) 3 - - 3r 3.44 -88.11 3e 2.93 -75.12 2 - - 2r 2.93 -75.12 2e - - 2n 2.93 -75.12 1 - - 1' - - 3810 S Teakwood St - 2018104710/5/2023 LAG SCREW ANALYSIS Loads Wind Pressures qz =-75.12 psf Solar Panel Load QD =3 psf Panel Length l =5.975 ft Panel Width b 3.3333 ft Attachment Spacing s =6 ft Portrait Tributary Area At =17.93 ft2 Wind Load PW = qz * At =-1346 lbs Dead Load PD = QD * At =53.775 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-776 lbs Landscape Tributary Area At = b * s =10 ft2 Wind Load PW = qz * At =-751 lbs Dead Load PD = QD * At =30 lbs Uplift Pa = 0.6 PD + 0.6 Pw =-433 lbs Lag Screw Specific Gravity of Lumber SG =0.50 (Douglas Fir-Larch) Diameter of Lag Screw D =5/16 in Withdraw Design /in 1800*SG3/2*D3/4 =266 lbs/in Depth of Embedment lp =2.50 in Total Nominal Withdrawal Value W = W * l p =665 lbs Load Duration Factor CD =1.6 Withdrawal Design Value W' = W * C D =1064 lbs Demand Capacity Ratio DCR = Pa / W'=0.73 < 1 OK 3810 S Teakwood St - 2018104710/5/2023 ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check Roof Slope =12 ° Roof Shape Gable Tributary Width s =2.00 ft Tributary Length L =15.00 ft Effective Area A = L ( MAX [ s , L/3] )=75 ft2 Height of Structure h =15 ft Wind Speed V =110 mph Exposure Category C Building Width B =35 ft Building Length L =50 ft Zone Width a =3.5 ft Elevation Height zg =40 ft Wind Directionality Kd =0.85 Topography Factor Kt =1.00 Ground Elevation Factor Ke =1.00 Velocity Pressure Exposure Coefficient Kz =0.85 Velocity Pressure qz = 0.00256KzKztKdKeV2 =22.32 psf Internal Pressure Coefficient (GCpi)=-0.18 Zone GCp p = qz [(GCp) - (Gcpi)] 3 - - 3r 2.30 -55.35 3e 2.46 -58.88 2 - - 2r 2.46 -58.88 2e - - 2n 2.46 -58.88 1 - - 1' - - 3810 S Teakwood St - 2018104710/5/2023 Beam/ Top Chord Check Lumber: Moment Demand # of Attachment per Rafter NA =Span :Orientation Lenght (ft) : Dead Load Roof Material:QD =psf Live Load QLr =psf Wind Load p = psf Snow Load QS =psf Rafter Spacing s = in Wind Load, Portrait Portrait UL = Wind Load, Landscape Landscape UW = Linear Dead Load wd =plf Live Load wLr = plf Start ft Start ft End ft End ft Snow Load ws = plf Start ft Start ft End ft End ft Ma, Moment D lb-ft D+Lr lb-ft D+S lb-ft 0.6D+0.6W lb-ft D+0.45W+0.75Lr lb-ft D+0.45W+0.75S lb-ft Moment Capacity Framing Member Size Lumber Grade : DF-L No. 2 CM = 1 Ct = 1 Cr= CF = fb =psi Cfu =Ci = Breadth b = in Depth d = in Section Modulus Sx = bd2 / 6 =in3 Bending Stress Capacity Fb = CM * Ct * Cr * CF * fb =psi Table 4.3.1 NDS 2018 Deflection Limit E = ksi I =in4 Transient Deflection in Transient Deflection Allowed > [OKAY] Total Deflection in Total Deflection Allowed > [OKAY] 1.0 1 20 0.00 24 TILE 0.076 1111 180 1.6 2153 psi D+0.45W+0.75S 637 psi 0.30 OKAY 1.6 2153 psi D+0.45W+0.75Lr 637 psi 0.30 OKAY 1.6 2153 psi 0.090 932 120 1600 20.80 0.6D+0.6W 1177 psi 0.55 OKAY 1.15 1547 psi D+S 446 psi 0.29 OKAY OKAY 1.25 1682 psi D+Lr 452 psi 0.27 OKAY DCR 0.9 1211 psi D 446 psi 0.37 7.56 1346 CD Fb' = CD * Fb ASD Load Ma / Sx 2x6 1.15 1.3 15.00 13.45 15.00 900 1.50 5.50 281 285 281 742 402 402 0 0.0 0 1.5 0 0 0.0 Portrait 1.5 0.0Portrait0 0.0 0.0 AT (ft2) 17.925 10 pd (lbs) 53.775 -1055 pw (lbs) ps (lbs) 0 13.4540 0.0 0.0 0.0 0.0 0 0.0Portrait0 0.030 -589 0 0 0.0Portrait0 0.0 0.0 0 0.0 34 1 2 3 4 Eave 2 0.0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0 0.0 0.0 0.0 7.00 7.00 0.00 0.00 1.00 Portrait 3 8.3 53.8 17.00 -58.88 DF-L No. 2 4 j lj (ft)pd,j (lbs) pw,j (lbs) ps,j (lbs) Portrait 1 2.3 53.8 -1055 0.0 6.7 53.8 -1055 -1055 0.0 4 12.7 53.8 -1055 0.0 𝑴𝒙 𝑹𝒊𝒙 𝑳𝒊 𝑷𝒋𝒙 𝒍𝒋 𝒘𝒅𝒙𝟐 𝟐 ‐1000.0 ‐500.0 0.0 500.0 1000.0 0.000 2.000 4.000 6.000 8.000 10.000 12.000 14.000 16.000 3810 S Teakwood St - 2018104710/5/2023 SEISMIC WEIGHT COMPARISON / ANALYSIS - (PER CEBC 2022 Part 10 Chapter 5 Section 502.5) PV System Weight Module Model REC Panel Weight W panel = 45 lbs Number of Panels NPV = 10 Total PV System Weight W PV = W panel * NPV =450 lbs Existing Roof Weight Roof Weight QD =17.0 psf Building Length Lbuild =50 ft Building Width W build =35 ft Roof Area Abuild =1750 ft2 Building Perimeter Pbuild =170 ft Wall Height ht =8 ft Wall weight Qwall =15 psf Interior wall weight Qint =10 psf Roof Load W floor = Abuild * QD =29750 lbs Wall LoadW wall = ht /2 * Qwall * Pbuild + Abuild * Qint /2 =18950 lbs Total Story Weight W build = W floor + W wall =48700 lbs Percentage Weight Increase WPV / Wbuild = 0.92% < 10% OKAY 3810 S Teakwood St - 2018104710/5/2023 3810 S Teakwood St - 2018104710/5/2023 To, Building and Safety Department City of Santa Ana 20 Civic Center Plaza Sant Ana 92701 Sub: Letter of Authorization I, Kim Tong, hereby give authorization to Aikyum Solar located at 7256 Garden Grove Blvd, Westminster, California 92683 to install solar on my roof top and pull the solar permit from the City of Santa Ana on my behalf. Thank you for your prompt attention to my application. Sincerely, Date: Kim Tong 3810 Teakwood St, Santa Ana, CA 9270 7 DocuSign Envelope ID: E147757B-67B5-40A8-AFC3-B3178A8B391D 9/15/2023 3810 S Teakwood St - 2018104710/5/2023 Rev: 7/15/2021 RESIDENTIAL PHOTOVOLTAIC CHECKLIST SOL-01 CBC 2019 Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only Instructions: The licensed contractor of record shall complete all sections, answer the ten questions and sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of minimum 11” x 17” size. If answering NO to any of the questions, plan check shall be required. Project Address: Contractor Company Name: Contractor License Number: YES NO Are the following applicable to the proposed project? 1. Will the PV system layout provide the required three-foot wide clear access pathways per Section 605.11 of the California Fire Code, and is this shown on the roof plan? 2. Will the PV system be installed on a roof having only one roofing layer with no overlays? 3. Will the PV array be flush mounted to the existing roof so that the plane of the modules (panels) are parallel to the plane of the roof? 4. Will the PV system weigh maximum 4 pounds per square feet or less? 5. Will the PV system be installed where the modules do not overhang any roof edges (such as eaves, gabled ends, ridges and hips)? 6. Will the PV system be installed with a space of 2” minimum to 10” maximum between the underside of modules and the surface of the roof? 7. Will the PV system be installed without using any ballast system or counter-weight system? 8. Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet and is this maximum horizontal spacing shown on the plans? 9. Will the minimum 5/16” lag screws be installed with a minimum of 2-1/2 inch embedment into roof rafters (with pre-drilled holes) and is this minimum embedment shown on the plans? 10. Are ALL the structural pages of the plans stamped and signed by a California licensed professional engineer? (including project specific site plan, PV layout, anchorage spacing, anchorage details and manufacturer’s PV support information.) I certify under penalty of perjury under the laws of the State of California that the above is true: Print Name: Signature: Phone Number: Date: Email Address: Planning & Building Agency Building Safety Division 20 Civic Center Plaza P.O. Box 1988 (M-19) Santa Ana, CA 92702 (714) 647-5800 www.santa-ana.org 3810 S Teakwood St - 2018104710/5/2023