Loading...
HomeMy WebLinkAbout401 N Main St - 101118376 - Plan401 N. MAIN STREET PERMIT DRAWINGS - 01.23.24 23-0393 PLANS PREPARED BY: HELEN BECERRA, DESIGNER - JB3D INC. 01/23/2024 TABLE OF CONTENTS SHEET NUMBER PAGE DESCRIPTION 1.0 SIGN LOCATION PLAN 2.0 SIGN TYPE 3: MAIN ENTRY LEASING SIGN 3.0 SIGN TYPE 3A: HISTORICAL SIGN 4.0 SECTION DETAIL City of Santa Ana Planning & Building Agency Access to any power supply in attic or above ceiling shall be immediately from a ladder or with a 2X3 foot access door & passage with a 12-inch walkway. CEC 600-21 (d)(d) Bldg# 101118376 Elec# 20182185 APPROVALS: BLDG - TLe PLNG - CSantana 401 N Main St - 1011183763/12/2024 SITE PLAN 1” = 40’HCB DRAWING TITLE SCALE DESIGNERCONTACT CLIENT JOB# 01.23.24 DATE SHT# 1.0 The following drawings, specifications, ideas, designs, and arrangements represented thereby, are and shall remain the property of the designer, and no part thereof shall be copied, disclosed to others or used in connection with any work or project other than the specified project for which they have been prepared and developed without the written consent of the designer. Visual contact with these plans or specifications shall constitute conclusive evidence of acceptance of these restrictions. 731 N. MAIN ST ORANGE, CA 9 2868 714.74 4.2 300 PI W / T o l l B r o t h e r s / R A F F E R T Y / 2 3 - 0 3 9 3 R a f f e r t y / P e r m i t S e t / H i s t o r i c a l S u b m i t t a l 1 / R a f f e r t y - H i s t o r i c a l F a c a d e - P e r m i t S e t V 1 . a i PLANS PREPARED BY: HELEN BECERRA, DESIGNER - JB3D INC. 01/23/2024 RAFFERTY 401 N. MAIN ST SANTA ANA, CA 92701 23-0393TOLL BROTHERS JOHN HYDE N. BUSH S T REE T 4 T H S T R E E T E . 5 T H S T R E E T 4 01 N. MAIN ST. (BUILDING 1) MAIN S T REE T PROPERTY LINE SIGN TYPE - LEGEND 3. Main Leasing Entry Sign (1) 3A. Historical Sign (1)250' 250' 3.1 3A.1 401 N Main St - 1011183763/12/2024 ST-3: MAIN LEASING ENTRY SIGN AS NOTED HCB DRAWING TITLE SCALE DESIGNERCONTACT CLIENT JOB# DATE SHT# 2.0 The following drawings, specifications, ideas, designs, and arrangements represented thereby, are and shall remain the property of the designer, and no part thereof shall be copied, disclosed to others or used in connection with any work or project other than the specified project for which they have been prepared and developed without the written consent of the designer. Visual contact with these plans or specifications shall constitute conclusive evidence of acceptance of these restrictions. 731 N. MAIN ST ORANGE, CA 9 2868 714.74 4.2 300 TOLL BROTHERS JOHN HYDE 23-0393 PLANS PREPARED BY: 01.23.24 PI W / T o l l B r o t h e r s / R A F F E R T Y / 2 3 - 0 3 9 3 R a f f e r t y / P e r m i t S e t / H i s t o r i c a l S u b m i t t a l 1 / R a f f e r t y - H i s t o r i c a l F a c a d e - P e r m i t S e t V 1 . a i HELEN BECERRA, DESIGNER - JB3D INC. 01/23/2024 ST-3 - MAIN LEASING ENTRANCE SIGN - WEST ELEVATION SCALE: 1/8” = 1’ 1. DESIGN NOTES: 3” DEEP FABRICATED ALUMINUM PAN CHANNEL HALO-LIT LETTERS. PAINT FINISH ON FACE AND RETURNS. PINNED 1 1/2” OFF WALL FACE WITH SPACERS PAINTED TO MATCH WALL COLOR. P5 ST-3A ST-3 - MAIN LEASING ENTRANCE SIGN SCALE: 1/4” = 1’SIGN AREA = 42.08 SF EQ.EQ. 30" P5. COLOR NOTES: AKZO NOBEL SATIN BLACK PAINT ACCESSIBLE SPACE FOR ILLUMINATION A 4.0 13'-0 1/2" 20'-1 1/2" 21'-0 1/2" 24" 18" 12" EQ. EQ. EQ. 23" 13" 2'-6" EQ. 1 32 ' - 0 " RAFFERTY 401 N. MAIN ST SANTA ANA, CA 92701 401 N Main St - 1011183763/12/2024 ST-3A: HISTORICAL SIGN AS NOTED HCB DRAWING TITLE SCALE DESIGNERCONTACT CLIENT JOB# DATE SHT# 3.0 The following drawings, specifications, ideas, designs, and arrangements represented thereby, are and shall remain the property of the designer, and no part thereof shall be copied, disclosed to others or used in connection with any work or project other than the specified project for which they have been prepared and developed without the written consent of the designer. Visual contact with these plans or specifications shall constitute conclusive evidence of acceptance of these restrictions. PLANS PREPARED BY: 731 N. MAIN ST ORANGE, CA 9 2868 714.74 4.2 300 TOLL BROTHERS JOHN HYDE 23-0393 01.23.24 PI W / T o l l B r o t h e r s / R A F F E R T Y / 2 3 - 0 3 9 3 R a f f e r t y / P e r m i t S e t / H i s t o r i c a l S u b m i t t a l 1 / R a f f e r t y - H i s t o r i c a l F a c a d e - P e r m i t S e t V 1 . a i HELEN BECERRA, DESIGNER - JB3D INC. 01/23/2024 ST-3A - HISTORICAL SIGN - WEST ELEVATION SCALE: 1/8” = 1’ 1. 2. DESIGN NOTES: 2” DEEP FABRICATED ALUMINUM LETTERS WITH BRONZE PAINT FINISH. INSTALLED FLUSH TO WALL. 1 1/2” DEEP FABRICATED ALUMINUM LETTERS WITH BRONZE PAINT FINISH. INSTALLED FLUSH TO WALL. P9 ST-3A - HISTORICAL SIGN SCALE: 1/4” = 1’ EQ.EQ. 30" P9. COLOR NOTES: AKZO NOBEL CUSTOM BRONZE ACCESSIBLE SPACE FOR ILLUMINATION A 4.0 13'-0 1/2" 20'-1 1/2" 21'-0 1/2" 24" 18" 12" EQ. EQ. EQ. 23" 13" 2'-6" EQ. 1 2 P9 ST-3 SIGN AREA = 73.8 SF 24'-7" 12 ' - 1 1/2" 26 ' - 6 " RAFFERTY 401 N. MAIN ST SANTA ANA, CA 92701 401 N Main St - 1011183763/12/2024 SECTION DETAIL (SIGN 3 & 3A) AS NOTED HCB DRAWING TITLE SCALE DESIGNERCONTACT CLIENT JOB# DATE SHT# 4.0 The following drawings, specifications, ideas, designs, and arrangements represented thereby, are and shall remain the property of the designer, and no part thereof shall be copied, disclosed to others or used in connection with any work or project other than the specified project for which they have been prepared and developed without the written consent of the designer. Visual contact with these plans or specifications shall constitute conclusive evidence of acceptance of these restrictions. 731 N. MAIN ST ORANGE, CA 9 2868 714.74 4.2 300 TOLL BROTHERS JOHN HYDE 23-0393 PLANS PREPARED BY: 01.23.24 PI W / T o l l B r o t h e r s / R A F F E R T Y / 2 3 - 0 3 9 3 R a f f e r t y / P e r m i t S e t / H i s t o r i c a l S u b m i t t a l 1 / R a f f e r t y - H i s t o r i c a l F a c a d e - P e r m i t S e t V 1 . a i HELEN BECERRA, DESIGNER - JB3D INC. 01/23/2024 P5 P5 P6 1 1/2"3" REMOTE 12V LED DRIVER LOCATED IN INTERIOR OF BUILDING. 120-277V ELEC FEED PROVIDED BY OTHERS. ALL BUILDING PENETRATIONS TO BE SEALED DURING INSTALL WITH GE-1200 SILICONE P5. P6. P9. COLOR NOTES: AKZO NOBEL SATIN BLACK PAINT AKZO NOBEL TO MATCH SW7655 STAMPED CONCRETE AKZO NOBEL CUSTOM BRONZE SECTION DETAIL SCALE: 3"= 1'A 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. DESIGN NOTES: .050 ALUMINUM RETURNS WITH PAINT FINISH. S.S. FLAT HEAD FASTENERS W/ PAINTED HEADS TO MATCH RETURNS. INTERIOR OF LETTER PAINTED WHITE. NYLON SPACERS PAINTED TO MATCH BUILDING COLOR (P6). .063 THK. ALUMINUM FACE W/ PAINT FINISH. AA 4500K LEDS OR EQUIV. .188” THK. CLEAR LEXAN BACKS WITH DIFFUSER TO AVOID HOT SPOTS. CONCRETE ANCHORS. MIN 4 PER LETTER. ALUMINUM CLIPS. WEEP HOLES ON BOTTOM OF LETTERS AS REQUIRED. INTERNAL BAFFLE TO PRECENT LIGHT LEAKS. 2” DEEP FABRICATED ALUMINUM LETTERS WITH BRONZE PAINT FINISH. INSTALLED FLUSH TO WALL. 1 1/2” DEEP FABRICATED ALUMINUM LETTERS WITH BRONZE PAINT FINISH. INSTALLED FLUSH TO WALL. 1 2 3 4 5 6 7 8 9 10 2" 1 1/2" P9 11 P9 12 8 RAFFERTY 401 N. MAIN ST SANTA ANA, CA 92701 401 N Main St - 1011183763/12/2024 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 172258-0124-0002 Report Generated: 2024-01-23 11:53:00 STATE OF CALIFORNIA Sign Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTS-E This document is used to demonstrate compliance with requirements in 110.9, 110.12, 130.0/ 160.5, 130.3/ 160.5(d), 140.8/ 170.2(e) and 141.0(b)2M/ 180.2(b)4Bvi for sign lighting scopes using the prescriptive path. Exit signs and traffic signs are not required to comply with prescriptive requirements per exceptions to 140.8/ 170.2(e) and do not need to complete this compliance document. Project Name: Rafferty Report Page:(Page 1 of 4) Project Address:Date Prepared:2024-01-23T14:52:58-05:00 A. GENERAL INFORMATION 01 Project Location (city)Santa Ana 02 Climate Zone 8 03 Occupancy Types within Project Healthcare Facility Multifamily/ MF Mixed-use >= 4 stories (includes dormitory, senior living) B. PROJECT SCOPE This table includes illuminated signs that are within the scope of the permit application and are demonstrating compliance using the prescriptive path outlined in 140.8/ 170.2(e) or 141.0(b)2M/ 180.2(b)4Bvi for alterations. Exit signs and traffic signs are not required to comply with prescriptive requirements per exceptions to 140.8/ 170.2(e) and do not need to complete this compliance document. 01 02 03 04 05 Name or Item Tag Complete Sign Description Sign Status1 Sign Type Compliance Method2 ST-3 Main Leasing Entry Sign Halo-illuminated channel letters New Outdoor Max Allowed Lighting Power 1FOOTNOTE: Sign alterations that increase the connected lighting load, replace and rewire more that 50% of the ballasts, or relocate the sign to a different location must comply with 140.8/ 170.2(e). See 141.0(b)2M/ 180.2(b)4Bvi for more details. 2The ENERGY VERIFIED Label compliance method is only applicable if the sign has a permanent, factory-installed, ENERGY VERIFIED label certified by UL or comparable, confirming the sign complies with 140.8/ 170.2(e). Note that using an ENERGY VERIFIED label is an optional compliance path, not a mandatory requirement. See the tooltips for this table for more details. 401 N Main St, Santa Ana CA 92701 401 N Main St - 1011183763/12/2024 STATE OF CALIFORNIA Sign Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTS-E Project Name: Rafferty Report Page:(Page 2 of 4) Date Prepared:2024-01-23T14:52:58-05:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 172258-0124-0002 Report Generated: 2024-01-23 11:53:00 C. COMPLIANCE RESULTS Results in this table are automatically calculated from data input and calculations in Tables B through H. Note: If any cell on this table says "COMPLIES with Exceptional Conditions" refer to Table D. Exceptional Conditions for guidance or see applicable Table referenced below. 01 02 03 ≥ 04 OR 05 OR 06 07 Name or Item Tag (See Table B) Complete Sign Description (See Table B) Total Allowed (Watts) (See Table F) Total Designed (Watts) (See Table F) Compliant Light Sources (See Table G) ENERGY VERIFIED Label (See Table H) Compliance Results ST-3 Main Leasing Entry Sign Halo-illuminated channel letters 505.2 ≥325 OR OR COMPLIES Controls Compliance (See Table F/G/H for Details)COMPLIES D. EXCEPTIONAL CONDITIONS This table is auto-filled with uneditable comments because of selections made or data entered in tables throughout the form. E. ADDITIONAL REMARKS This table includes remarks made by the permit applicant to the Authority Having Jurisdiction. F. MAXIMUM ALLOWED LIGHTING POWER AND CONTROLS This table includes illuminated signs using the Maximum Allowed Lighting Power compliance method per 140.8(a) / 170.2(e) as indicated on Table B of this compliance document. It also demonstrates compliance with mandatory controls requirements from 130.3 / 160.5(d) by indicating control types for each sign. 01 02 03 04 05 06 07 08 09 Name or Item Tag Complete Sign Description Illumination Method Sign Area (ft2) Allowed Density (W/ft2) Allowance (Watts) Design Watts Mandatory Controls Field Inspector Shut-Off Dimming Demand Response1 Pass Fail ST-3 Main Leasing Entry Sign Halo-illuminated channel letters Internally 42.1 12 505.2 325 Automatic Time Switch + Photocontrol (outdoor) Power reduced 65%+ 401 N Main St - 1011183763/12/2024 STATE OF CALIFORNIA Sign Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTS-E Project Name: Rafferty Report Page:(Page 3 of 4) Date Prepared:2024-01-23T14:52:58-05:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 172258-0124-0002 Report Generated: 2024-01-23 11:53:00 F. MAXIMUM ALLOWED LIGHTING POWER AND CONTROLS * NOTES: Controls with a * require a note in the space below explaining how compliance is achieved. EX: Sign within tunnel illuminated day and night; EXCEPTION to 130.3(a)2A. 1 FOOTNOTE: Demand response controls are only required for an Electronic Message Center having a new connected lighting power load greater than 15 kW per 110.12(d) G. LIGHT SOURCES AND CONTROLS This section does not apply to this project. I. DECLARATION OF REQUIRED CERTIFICATES OF INSTALLATION Selections have been made based on information provided in this document. If any selection have been changed by permit applicant, an explanation should be included in Table E. Additional Remarks. These documents must be provided to the building inspector during construction and can be found online Form/Title NRCI-LTS-E - Must be submitted for all buildings J. DECLARATION OF REQUIRED CERTIFICATES OF ACCEPTANCE There are no forms required for this project. 401 N Main St - 1011183763/12/2024 STATE OF CALIFORNIA Sign Lighting CALIFORNIA ENERGY COMMISSION CERTIFICATE OF COMPLIANCE NRCC-LTS-E Project Name: Rafferty Report Page:(Page 4 of 4) Project Address:Date Prepared:2024-01-23T14:52:58-05:00 Generated Date/Time:Documentation Software: Energy Code Ace CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 Schema Version: rev 20220101 Compliance ID: 172258-0124-0002 Report Generated: 2024-01-23 11:53:00 DOCUMENTATION AUTHOR'S DECLARATION STATEMENT I certify that this Certificate of Compliance documentation is accurate and complete. Documentation Author Name: Helen Becerra Documentation Author Signature: Company:Signature Date: Address:CEA/ HERS Certification Identification (if applicable): City/State/Zip:Phone: RESPONSIBLE PERSON'S DECLARATION STATEMENT I certify the following under penalty of perjury, under the laws of the State of California: 1. The information provided on this Certificate of Compliance is true and correct. 2. I am eligible under Division 3 of the Business and Professions Code to accept responsibility for the building design or system design identified on this Certificate of Compliance (responsible designer) 3. The energy features and performance specifications, materials, components, and manufactured devices for the building design or system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations. 4. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application. 5. I will ensure that a completed signed copy of this Certificate of Compliance shall be made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a completed signed copy of this Certificate of Compliance is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Designer Name: Helen Becerra Responsible Designer Signature: Company:Date Signed: Address:License: City/State/Zip:Phone: Truemark Inc., dba JB3D 01.23.2024 731 N Main Street 714.204.0077Orange, CA 92868 Truemark Inc., dba JB3D 01.23.2024 731 N Main Street 926653 Orange, CA 92868 7142040077 401 N Main St, Santa Ana CA 92701 401 N Main St - 1011183763/12/2024 401 N Main St - 1011183763/12/2024 401 N Main St - 1011183763/12/2024 401 N Main St - 1011183763/12/2024